1 CONVERTER Wiegand 1-Wire (Dallas) Z-26 USER MANUAL AND INSTRUCTIONS
2 Contents Purpose and Main Operation Principle... 3 Technical Specifications... 3 Description and Placement of Converter Ports... 4 Converter Operation Modes... 5 Examples of Converter Usage... 7 Delivery Set... 9 Warranty... 9 Acceptance certificate Sale mark
3 Purpose and Main Operation Principle The controller is intended for conversion interface Wiegand (-4, -8, -26, -34) into 1-Wire (Dallas) and vice versa interface 1-Wire (Dallas) into Wiegand-26. Technical Specifications Supply voltage, DC 12 V Consumption current, not more than 20 ma Reader operation protocol Wiegand, 1-Wire Controller operation protocol Wiegand, 1-Wire Dimensions, not more 55 x 30 mm Distance between converter and devices: - 1-Wire (Dallas) 10 m - Wiegand (-4, -8, -26, -34) 100 m Service Conditions Operating temperature range С Relative humidity at +15 С 80% Relative humidity at +25 С 90% 3
4 Description and Placement of Converter Ports Fig. 1. Ports placement on board P1 Port 1-Wire. The port is intended for connection of devices (reader, keyboard and controller) with the interface 1-Wire. It contains two terminal block outputs. Port placement is illustrated on the fig. 1, where: DS 1-Wire information output; GND 1-Wire return ground. P2 Port RS-232. The port is intended for connection of communication interface RS-232. It is used to transmit data in ASCII format from converter to computer. The port contains three terminal block outputs. Port placement is illustrated on the fig. 1, where: RX data reception; TX data transmission; GND RS-232 ground. 4
5 P3 Port Wiegand. The port is intended for connection of devices (reader, keyboard, controller) with the interface Wiegand. It contains three terminal block outputs. Port placement is illustrated on the fig. 1, where: D0 Wiegand information input; D1 Wiegand information input; GND Wiegand return ground. P4 Port for supply voltage (+12V) input. It is used to connect power source of 12V. The port contains two terminal block outputs. Port placement is illustrated on the fig. 1, where: GND power source ground. J Set of jumpers, which determine converter operation mode: 1. 1-Wire > Wiegand (position 1-2). 2. Wiegand > 1Wire (position 2-3). Converter Operation Modes The converter may operate in one of the following modes: 1. Conversion of the 1-Wire (Dallas) interface into Wiegand Conversion of the Wiegand (-4, -8, -26, -34) interface into 1-Wire (Dallas). Converter operation mode is determined by the position of jumpers J as figure 2 shows. Attention! Before changing jumpers position de-energize the converter! Fig.2 Jumpers positioning 1.) 1-Wire->Wiegand. 2.) Wiegand->1-Wire 5
6 When operating in mode Wiegand->1-Wire the following points should be taken into consideration to enter a code via keyboard: The converter is able to receive only digits from 0 to 9. The maximal admissible length of a code is 10 digits. When entering a code of less than 10 digits, code combination should be completed by pressing the Enter(#) button. Entered combination may be canceled by pressing Esc(*) button. Time interval between digits serial entering should be not more, than 5 seconds. If specified interval is exceeded, entered combination is reset. Attention! The converter was tested using controller Z5R. When connecting a reader with interface Wiegand or any analogous interface (operating with interface 1-Wire) to a Z5R controller through converter Z-26, the following points should be taken into consideration: Reader transmits the read-in code just once and, thus, converter does not support such operations as programming of the Z5R controller using MASTER_KEY. User keys may only be entered using controller jumpers. To transmit data in the ASCII format from converter to the computer (COMport) through the RS-232 communication interface the following terminal parameters should be set: - baud rate 19200; - bit - 8; - parity - no; - stop bits 1. Fig.3. Communication interface RS-232 6
7 Examples of Converter Usage The main purpose of the converter is to interconnect readers with Wiegand interface and controller with 1-Wire (Dallas) interface. Additional functionality of the converter is the possibility to connect it to the personal computer via RS-232 interface with the purpose to transmit data (code keys), handled by the converter, into the Terminal. Figures below depict examples of devices connection to the converter. Fig. 4. Connection of the reader with Wiegand interface to the controller with 1-Wire interface through the converter Z-26 7
8 Fig. 5. Connection of 2 readers with Wiegand interface (Input and Output) to the controller with 1-Wire interface through the converter Z-26 Note: Connection of a certain type of readers may require usage of diodes (D1 D4). We recommend using Schottky diodes. 8
9 Delivery Set The delivery set includes: converter Z-26, technical description and package. Warranty Warranty life of the device is 18 months starting from the date of sale, but not less than 24 month from the date of manufacture. The warranty is considered void and claims are not accepted in the following cases: incorrect connection. nonobservance of specifications given in the present user manual. delayed servicing (once a year). presence of mechanical damage. natural calamity (thunderstorm, etc.). presence of exposure to deleterious substances or insects. marks of unwarranted interference. During the warranty period the Manufacturer will repair the device, if the malfunctions occur through the Manufacturer fault, or will replace malfunctioned nodes free of charge. The repair is performed on the Manufacturer s territory or in the authorized repair shops. The Manufacturer reserves the right to make changes and/or improvements not affecting device main technical parameters and product liability without Client notice. Should any questions regarding warranty repair arise address the Manufacturer or device Seller. 9
10 Manufacturer: «ABRAIT» OOO Location: Russian Federation, City: Saint-Petersburg, str. Partisan 27, of. 406 Postal Code: Phone: +7 (812) Trade mark «ABRAIT» SRL Republica Moldova, or. Chişinău, str. Alba Iulia 75 bl. «N» Acceptance certificate Date of manufacture S/N Stamp of Quality Control Department Sale mark Date of sale Seller (signature 10
Operation instructions. Network reader/controller
LLC Pulsar-Telecom 195009, Russia, Saint-Petersburg, Bobruiskaya str.,7 Tel.: (812) 703-77-65, 542-04-80 Fax: (812) 542-11-85 Operation instructions 105122, Russia, Moscow, Schelkovskoye Highway, 2, office
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More informationNMEA 0183 Amplifier-distributor Unit With Integrated Combiner ADU-202
NMEA 183 Amplifier-distributor Unit With Integrated Combiner ADU-22 Technical Documentation (22-2-67212) St. Petersburg 212 Table of Contents 1. GENERAL INFORMATION...4 2. DELIVERY SET...4 3. TECHNICAL
More informationETHERNET MODULE RS-LAN. Instruction manual 03/02.17
ETHERNET MODULE RS-LAN Instruction Manual 03/0.7 General Description The interface module RS-LAN is an auxiliary device for establishment the communication of Fire Control Panels, manifactured by UniPOS
More informationI/O SIGNAL CONDITIONER
Technical Data Sheet No. TD9809M Rev. F Date of Issue: December 9, 2009 OPERATING MANUAL I/O SIGNAL CONDITIONER CAUTION: THIS PRODUCT DOES NOT PROVIDE GALVANIC ISOLATION. DO NOT ATTEMPT USE OF THIS PRODUCT
More informationUSB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL
USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL Contents 1. APPLICATION... 5 2. CONVERTER SET... 5 3. CONVERTER INSTALLATION... 6 3.1. Converter installation and safety requirements... 6 3.2. Description
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More informationETConcept Systems Engineering. User s Guide
Wiegand to RS485 Converter User s Guide Nov-08 Copyright 2008. All rights reserved including the right of reproduction in whole or in part in any form. Contents List of Accessories Included... 1 List
More informationProximity Card Reader IR-10
Proximity Card Reader IR-10 CERTIFICATE AND OPERATION MANUAL PERCo-Web system Proximity Card Reader IR-10 Certificate and Operation Manual TC RU C-RU.МЛ02.В.00273 ТУ 4372-040-88226999-2014 CONTENTS 1 GENERAL
More informationTEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL
TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL 1 2 CONTENTS 1. APPLICATION... 5 2. BASIC REQUIREMENTS, OPERATIONAL SAFETY... 5 3. INSTALLATION... 5 3.1. Assembly...5 3.2. Electrical Connections...7
More informationmanufactured by SF8150-ZIF14
manufactured by manufactured by SF8150- ZIF14 Butterfly packaged laser diode controller Datasheet & Users Manual Before powering on your driver, read this manual thoroughly. If you have any doubt or suggestion,
More informationRXTH DUAL ROOM SENSOR / SWITCH
DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE
More informationRST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND
More informationSerial to Ethernet Converter HL-SE02P-V1. User s Manual V3.606
Serial to Ethernet Converter HL-SE02P-V1 User s Manual V3.606 UContents Table Welcome... 2 Package Contents. 2 Feature. 2 Application 3 Specification. 4 Hardware Guide 5 Ping Assignments. 6 Factory Default
More informationINTMOD485-LH Protocol Converter
For Use with L-GAGE LH Series Sensors Features Converts an LH Network to the 485-RTU protocol Supports baud rates up to 230,400 baud Supports LH Networks with up to 32 sensors Model Protocol Conversion
More informationSerial Port Plug - F2M01SXA Brief Datasheet. Features. Applications. General Description. Provides transparent RS-232 serial cable replacement.
Serial Port Plug - F2M01SXA Features Provides transparent RS-232 serial cable replacement. No need for external drivers. Power is supplied via the D-SUB or mini-usb connector. Supports the Bluetooth Serial
More informationRXTP ROOM TEMPERATURE
ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4
More informationInstallation and User Manual. version 1.00 MODWF 2014/53/UE EN : /30/UE EN55022:2010 EN :2005 EN :2007
Installation and User Manual version 1.00 MODWF 2014/53/UE EN300 328:2016 2014/30/UE EN55022:2010 EN61000-6-2:2005 EN61000-6-4:2007 SYSTEM IDENTIFICATION Load Cell Systems reserves the right to change
More informationRS485 MODBUS Module 8AO
Version 1.3 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationRS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount
Fiber-Optic Link to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount 101-0079 Installation Operation & Specifications Manual Auto-direcon control Supports BAUD rates up to 115,200 Fiber
More informationBefore powering on your driver, read this manual thoroughly. If you have any doubt or suggestion, please do not hesitate to contact us!
Laser diode driver Datasheet & UserManual Before powering on your driver, read this manual thoroughly. If you have any doubt or suggestion, please do not hesitate to contact us!, 37 Sedova St, Off 209,
More informationIndustriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH
Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical
More informationOperating Manual. English. Digital-Analog Converter DACON8-UMB.
English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before
More informationGPS tracker Voyager 2N
GPS tracker Voyager 2N Data sheet Device identification number 1. General Information 2 Voyager 2N is a GPS tracker (hereinafter referred to as the device) suitable for connection of external devices and
More informationRADON SS SENSOR pci/l
1. FEATURES Easy to use advanced technology Delivers complete set of information for instantaneous and average Radon concentrations Ideal for portable, fixed and digital applications 2. SPECIFICATION Measuring
More informationCU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:
CU8860-0000 USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date: 2006-02-20 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation 1 1.1.1 Liability Conditions 1 1.1.2 Conditions
More informationTechnical Documentation
Technical Documentation for metratec QR15 HF RFID Module Date: June 2015 Version: 1.8 Technical Documentation metratec QR15 Page 1 of 14 Table of Contents 1 General Information / Security Advice...3 1.1
More informationTechnical Description
B Content 1. Allgemeines...1 2. Blockdiagramm...2 3. Inbetriebnahme...2 4. Technische Daten...3 4.1 AS-Interface...3 4.2 Anschlussbelegung...3 4.3 LED Anzeige...4 4.4 Mechanische und Umgebungsdaten...4
More informationRN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 4/20/2011
www.rovingnetworks.com rn-174-ds v1.1 4/20/2011 WiFly GSX Super Module Features Development board containing the RN-171 module, status LEDs, power regulator Supports chip antenna (-C), PCB Trace antenna
More informationRFT(Robotous Force/Torque Sensor) Series
RFT(Robotous Force/Torque Sensor) Series Installation and Operation Manual REVISION 1.1 1 Contents 1. Caution 4 1.1. Notices 4 1.2. Warning 4 2. Installation 5 2.1. Overview 5 2.2. Power Supply Specifications
More informationMDA-8000 DIO User Manual
MDA-8000 DIO User Manual Warranty All products manufactured by Maxthermo-Gitta are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser.
More informationRN-174. WiSnap M2 Super Module. Features. Description. Applications. ~ page 1 ~ rn-174-ds v1.1 6/1/2011
WiSnap M2 Super Module Features Development board containing the RN-171 module, status LEDs, power regulator Supports chip antenna (RN-174-C), PCB Trace antenna (RN-174-P), wire antenna (RN- 174-W) and
More informationProximity Card Reader RP-15.2
Proximity Card Reader RP-15.2 CERTIFICATE AND OPERATION MANUAL Proximity Card Reader RP-15.2 Certificate and Operation Manual ТС RU C-RU.МЛ02.В.00073 ТУ 4372-015-88226999-2013 CONTENTS: 1. GENERAL INFORMATION...3
More informationCONVERTER OF RS-232/RS-485 INTERFACES PD51 TYPE USER S MANUAL
CONVERTER OF RS-232/ INTERFACES PD51 TYPE USER S MANUAL 1 2 CONVERTER OF RS-232/ INTERFACES PD51 TYPE USER S MANUAL CONTENTS 1. APPLICATION... 5 2. CONVERTER SET... 5 3. INSTALLATION OF PD51-A TYPE...
More informationMODBUS MASTER ALERTING SMS MODEM V1.50
User manual MODBUS MASTER ALERTING SMS MODEM V1.50 UASAGE NOTICE This software / document / material are property of Kurolikar Automation Research Labs (KARL PL) Pvt Ltd. It has been provided for the exclusive
More informationRN-174 WiFly Super Module
RN- WiFly Super Module Features Evaluation board for the RN- module Supports chip antenna (RN--C), PCB trace antenna (RN--P), wire antenna (RN--W), and U.FL connector for an external antenna (RN--U) Ultra-low
More informationRN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 3/3/2011
www.rovingnetworks.com rn-174-ds v1.1 3/3/2011 WiFly GSX Super Module Features Development board containing the RN-171 module, status LEDs, power regulator Supports chip antenna (-C), PCB Trace antenna
More informationAccess control panel U-Prox IC E (Elevator control)
1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter
More informationDual Serial Shield User Manual
Dual Serial Shield User Manual PN: 2050 Berkshire Products, Inc. Phone: 770-271-0088 http://www.bkp-store.com/ Rev: 1.00 Copyright 2013 Table of Contents 1 Introduction... 2 1.1 XB compatibility... 2 2
More informationisma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland
isma-b-fcu User Manual FCU Hardware Global Control 5 Sp. z o.o. Warsaw, Poland www.gc5.pl Table of contents 1 Introduction 3 1.1 Document change log 3 1.2 Safety rules 3 1.3 Technical specifications 4
More informationHardware Reference IO/5640. Analog/Digital I/O-Extension
IO/5640 Analog/Digital I/O-Extension Hardware Reference SSV Software Systems GmbH Dünenweg 5 D-30419 Hannover Phone: +49 (0)511/40 000-0 Fax: +49 (0)511/40 000-40 E-mail: sales@ssv-embedded.de Document
More informationTRBOnet Swift Mic Adapter M002
Microphone adapter TRBOnet Swift Mic Adapter M002 User Manual Neocom Software Ltd. 2017 Contents 1. Product description 2. Features 3. Delivery kit 4. Specification 5. Connectors and indication 6. Connection
More informationPLP-R1, PLP-RB1, PLP-R2, PLP-R4 Relay blocks for controlling high current load in CNC machines and automation system
PLP-R1, PLP-RB1, PLP-R2, PLP-R4 Relay blocks for controlling high current load in CNC machines and automation system INSTRUCTION MANUAL 01. General information 02. Delivery set 03. Technical features 04.
More informationSDM-8AO. Expansion Module 8 analog outputs. Manufactured for
Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationInterface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from
Interface RS485-TTL v.1.0 CODE: EN* Edition: 3 from 05.12.2013 Supersedes the: 2 from 19.12.2012 TABLE OF CONTENTS 1. General description.... 3 2. Components arrangements.... 3 3. Connection to the RS485
More informationDXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions
DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL
More informationThermoelectric Cooler Controller TED1000
Thermoelectric Cooler Controller TED1000 Operating Instructions MANUAL-TED1000-1.0 Aug 2015 Rev.1 2 Contents 1 General... 4 1.1 Warranty and Assistance... 4 1.2 Maintenance... 4 1.3 General Safety Considerations...
More information4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System
USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-022 2017A-0330 4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System SYSTEM INSTALLATION INFORMATION Description The 4 Channel
More informationOperating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO
Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...
More informationINSTALLATION GUIDE DM-20 English Version 1.10 EN DM20 V1.10A
www.supremainc.com INSTALLATION GUIDE DM-20 English Version 1.10 EN 101.00.DM20 V1.10A Contents Safety Instructions... 3 Components... 4 Front Side... 5 Installation Example... 6 Dimensions... 7 Installation...
More informationI/O232-A User s Guide
rmv electronics I/O232-A User s Guide DISCLAIMER: RMV ELECTRONICS INC. does not assume any liability arising from the application and/or use of the product/s described herein, nor does it convey any license.
More informationSBR The Chameleon Converter II
SBR 0981 The Chameleon Converter II Security Engineering 2003-2015 The Chameleon converter II: Concept: The Chameleon converter II is a one-fits-all protocol conversion PCB that is designed to host one
More informationKCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement
Our CO2 gas sensors get a small deviation unlike NDIR Single type. So they keep long term stability. KCD-HP100x Excellent stability and accuracy - through testing and calibration with sophisticated process
More informationUSER MANUAL. Longo programmable controller LPC-2.SM6 Multisensor. Version 4
USER MANUAL Longo programmable controller LPC-2.SM6 Multisensor Version 4 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0) 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si Written
More informationNetwork video surveillance camera RVi-IPC42Z12
Network video surveillance camera RVi-IPC42Z12 User s manual Please read before using and save for later use. www.rvi-cctv.ru Attention This symbol indicates that the device has a high voltage. Contact
More informationLecture-65 SERIAL DATA COMMMUNICATION The data bus of a microcomputer system is designed to transfer data to and from I/O device in parallel - all
Lecture-65 SERIAL DATA COMMMUNICATION The data bus of a microcomputer system is designed to transfer data to and from I/O device in parallel - all bits of a data word are transformed simultaneously. This
More information716 Converter. Programmable Data Converter
716 Converter Programmable Data Converter The 716 can perform over 30 different conversions, supporting Rs232, wieigand, magnetic stripe, wieaba, wand emulation, f2f, and others. Flash upgrading allows
More information8520/8520R. User Manual
/R User Manual Warranty All products manufactured by SuperLogics are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Disclaimer SuperLogics
More informationSINGLE READER EXPANSION MODULE
SINGLE READER EXPANSION MODULE INSTALLATION GUIDE A D C - A C X 1 TR- SINGLE READER EXPANSION MODULE The ADC-ACX1 Single Reader Expansion Module provides a solution for interfacing to a one Wiegand reader
More informationEVAcharge SE - Datasheet
EVAcharge SE - Datasheet Datasheet (valid for board revision V0R4 or higher) Document history Revision 1.0 2013-10-10 Initial release 1.1 2013-11-06 Typo corrections 1.2 2014-05-13 Removed serial IF 1.3
More informationLZR - U920/-U921. LASER MEASUREMENT DEVICE with bidirectional bus communication. User s Guide for product version 0500 and more
EN LZR - U920/-U92 LASER MEASUREMENT DEVICE with bidirectional bus communication User s Guide for product version 0500 and more 2 LASER MEASUREMENT DEVICE Other use of the device is outside the permitted
More informationUser's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction
User's Guide Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model 382280 382280 Introduction Congratulations on your purchase of the Extech 382280 Programmable DC Power Supply. This 200 watt
More informationInstallation Guide Serial Interface T942SI
Installation Guide 2003-02-8/ Ver. C Contents.... General... 2 Board Description... 2 3 Installation... 4 3. Mounting... 4 3.2 Opening the Housing... 4 3.3 Mounting together with other Units... 5 3.4 Wiring
More informationNMEA Expander. Operation And. Installation Manual
NMEA Expander Operation And Installation Manual XXXXXX_20130331 Revision B0 Syberg Maritim 1. OPERATION AND CONFIGURATION... 3 SYSTEM SUMMARY... 3 INPUT POWER SUPPLY, D CONFIGURATION... 4 INPUT POWER SUPPLY,
More informationADAM Fiber Optic to RS-232/422/485 Converter
ADAM-4542+ Fiber Optic to RS-232/422/485 Converter Overview Fiber optic transmission offers the benefits of wide bandwidth, immunity to EMI/RFI interface, and secure data transmission. The ADAM-4542+ can
More informationHA7E-User Manual ASCII RS232 to 1-Wire Host Adapter
HA7E-User Manual ASCII RS232 to 1-Wire Host Adapter http://www.embeddeddatasystems.com FEATURES ASCII command support for all 1-Wire devices. Powered by RS232 handshake lines. Automatic power up and power
More informationBusBlock Analog Input Module for the Smart Distributed System
BBK-4052-5 0414 TECHNICAL DATA Description The Holjeron BusBlock Analog Input Module is designed to handle small amounts of analog inputs in a limited amount of space. The BusBlock Analog Input Module
More informationDOLXFD1000B. Waterproof Access Control/Reader
DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to
More informationRS-232 Fiber Link Card System
USER GUIDE The leader in rugged fiber optic technology. U-152 2018B-0406 Fiber Link Card System SYSTEM INSTALLATION INFORMATION Introduction The Fiber Link Card system transports a full 9-Pin copper signal
More informationRS 485 Mini Modbus 1AO
RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained
More informationQUADIMODO. Quad-Band IP68 GSM MODEM. Quad Band for Worldwide Use. IP68 Enclosure Submersible. Voice / Fax / SMS and Data. GPRS Class B Class 10:
Quad-Band IP68 GSM MODEM Quad Band for Worldwide Use IP68 Enclosure Submersible Voice / Fax / SMS and Data GPRS Class B Class 10: Bundled 3V SIM Card included Internal Antenna (Optional External) RS232
More informationSCB-C08 USB to RS232/422/485 Converter
SCB-C08 USB to RS232/422/485 Converter USB Interface RS-232 signal RS-422 signal: RS-485 signal: Cable Type Transmission distance Signal LED Direct power from USB port Power consumption: Compliant with
More informationINSTRUCTION MANUAL WCS-Interface Module, DeviceNet
FACTORY AUTOMATION INSTRUCTION MANUAL WCS-Interface Module, DeviceNet WCS-DG210 Part. No. 202340 / DOCT-1305 / 11. june 2007 1 Working principle............................ 6 2 Installation and commissioning.................
More informationShort Operating Instruction for Digital Video Recorder mavr H.264SB
Short Operating Instruction for Digital Video Recorder mavr H.264SB Overlook The μavr-h.264sb audio/video recorder is intended for professional recording of video and audio signals onto flash memory card
More informationLT900SERIES. 1xN Multi-Channel Switch Operation Manual
LT900SERIES 1xN Multi-Channel Switch Operation Manual Table of Contents General Information.. 1 General Specifications...... 2 Interface Connectors..... 3 Connector Assignment 16 pin........ 4 26 pin....
More informationSegoSerial Industrial Grade Converter Isolated Dual RS232 - USB. Installation and operation. English Rev. 1.2 Status June I9
SegoSerial Industrial Grade Converter Isolated Dual RS232 - USB Installation and operation www.segosoft.info English Rev. 1.2 Status June 2013 1I9 Contents Introduction... 3 Product features... 3 Description
More informationTA0357. Overview of USB Type-C and Power Delivery technologies. Technical article. Introduction
Technical article Overview of USB Type-C and Power Delivery technologies Introduction The USB Type-C and Power Delivery technologies have revolutionized cable connectivity with the ability to carry all
More informationINJECTION EXPLORER STARDEX 0501
INJECTION EXPLORER STARDEX 0501 1. Security information Read the instructions carefully before using Stardex 0501 (the device). The device must be connected only to AC 220V with cable from the delivery
More informationIMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS WARNING RISK OF SEVERE INJURY OR DEATH To reduce the risk of death,
More informationHPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions
DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL
More informationRТTH DUAL ROOM SWITCH
DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA
More informationVirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual
VirtualSCADA USB to RS422/485 Isolated Converter User Manual Revision 1.01.00 Page 1 (15) Table of contents Warranty and support... 3 Product return... 3 1 About the VirtualSCADA USB to RS422/485 Converter...
More informationBOD2 & BOD4 Module User Manual - version
- version - by Copyright 2013 Tehnologistic SRL All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying,
More informationEco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features
Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use General and New Features The OS-6 is an industrial grade Ozone controller and monitor. The OS-6 design has been optimized for accuracy, ease
More informationUSER MANUAL. WBV412U01 AC voltage transducer
Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital Electrical Transducer since 1989 USER MANUAL WBV412U01 AC voltage transducer www.wb-my.com wblch@wbdz.cn Technical
More informationES-600 Ozone Controller Operation Manual
ES-600 Ozone Controller Operation Manual Questions about your product? Find answers here: Web: www.ozonesolutions.com/es-600 Phone: 712-439-6880 Ozone Solutions OZONE CONTROLLER Model ES-600 Instructions
More informationLow-Power-Radio Transceiver IC
Addressed Mode With Acknowledge Broadcast Mode Automatic Retry Serial Interface Stand Alone Operation Achieves Maximum Range From RF Modules Flow Control Option Two Telemetry I/O Lines (addressed mode
More informationZBXYAF Oxygen sensor control circuit board
FEATURES Control circuit board for all XYA series oxygen sensors Measuring ranges...5 or... oxygen or custom adjustable range Can be calibrated in normal air or any known O concentration Automatic or manual
More informationUSER MANUAL. Longo programmable controller LPC-2.ID2 RFID Card holder. Version 8
USER MANUAL Longo programmable controller LPC-2.ID2 RFID Card holder Version 8 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0) 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si
More informationDSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND
More information4 Channel RFID reader LF 125KHz with CAN bus LT-LFS03 USER MANUAL
4 Channel RFID reader LF 125KHz with CAN bus LT-LFS03 USER MANUAL 1/10 Product name 4 Channel RFID reader LF 125KHz with CAN bus LT-LFS03 User manual p/n Product rev. C01 Document p/n date LT-D-131 27/08/2013
More informationEVAcharge SE - datasheet
EVAcharge SE - datasheet Data Sheet (valid for board revision V0R4 or higher) Document history Revision 1.0 2013-10-10 Initial release 1.1 2013-11-06 Typo corrections 1.2 2014-05-13 Removed serial IF 1.3
More informationInstallation instructions Inclination sensor EC2019 EC / / 2013
Installation instructions Inclination sensor UK EC219 EC245 739215 / 3 1 / 213 Inhalt 1 Safety instructions 3 2 Mounting 4 3 Electrical connection 4 4 Dimensions 4 5 Technical Data 5 6 Characteristics
More informationExpansion Port RS485/RS422
Expansion Port RS485/RS422 www.lucom.de info@lucom.de USER S MANUAL USED SYMBOLS Used Symbols Danger important notice, which may have an influence on the user s safety or the function of the device. Attention
More informationBusBlock Analog Input Module for the Smart Distributed System
BBK-4052-3 0903 TECHNICAL DATA Description The Holjeron BusBlock Analog Input Module is designed to handle small amounts of analog inputs in a limited amount of space. The BusBlock Analog Input Module
More informationUSER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX
USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE
More informationDS2405. Addressable Switch PIN ASSIGNMENT
www.maxim-ic.com FEATURES Open-drain PIO pin is controlled by matching 64-bit, laser-engraved registration number associated with each device Logic level of open drain output can be determined over 1-Wire
More informationFULMATIC 7 SILVER SERIES PLC PLC USER S MANUAL
FULMATIC 7 SILVER SERIES PLC PLC USER S MANUAL A. GENERAL FEATURES Fulmatic 7 - Series PLCs are the programmable control devices which are designed according to the automation needs by considering the
More informationEagle PT-MP1 Pan Tilt Communications Multiplexer Installation and Operations Manual Revision 3.0 August 20, 2001
Eagle PT-MP1 Pan Tilt Communications Multiplexer Installation and Operations Manual Revision 3.0 August 20, 2001 Distributed by Hitachi Denshi America Ltd. 150 Crossways Park Drive Woodbury, NY 11797 (516)
More informationICF-1150 Series Quick Installation Guide
ICF-1150 Series Quick Installation Guide Second Edition, March 2012 2012 Moxa Inc. All rights reserved. P/N: 1802011500011 Overview Introduction The ICF-1150 series fiber converters are equipped with a
More information