TopSpin 3.5 Tips and Tricks. Nicole Kruse US Applications Pre PANIC Workshop February 20 th 2017
|
|
- Winifred Dickerson
- 6 years ago
- Views:
Transcription
1 TopSpin 3.5 Tips and Tricks Nicole Kruse US Applications Pre PANIC Workshop February 20 th 2017
2 Non-Uniform Sampling Incorporated into TopSpin 3.0 Higher Resolution NUS HSQC NS = 2 TD = % Expt = 20 minutes Regular HSQC NS = 2 TD = 256 Expt = 20 minutes Less Time NUS HSQC NS = 2 TD = % Expt = 2 minutes
3 Non-Uniform Sampling FREE in TopSpin 3.5 Compressed Sensing Mode of Processing 2D Data with the IST algorithm No Longer Requires a NUS license ** Much Improved IST algorithm in TS 3.5pl6
4 Non-Uniform Sampling FREE in TopSpin 3.5 Cyclosporine hsqcedetgpsisp2.3-2k x NUS IST IRLS No Virtual Echo Virtual Echo
5 Non-Uniform Sampling FREE in TopSpin 3.5 If you have the license additional options are available IRLS Algorithm mdd_csalg Virtual Echo mdd_csve # Iterations mdd_csniter An option even without license, but reduced data quality with IST algorithm
6 Non-Uniform Sampling FREE in TopSpin 3.5 Cholesterol Acetate hsqcedetgpsp.3-2k x 3.125% NUS IST IRLS No Virtual Echo Virtual Echo
7 Non-Uniform Sampling FREE in TopSpin 3.5 Cholesterol Acetate hsqcedetgpsp.3-2k x 3.125% NUS Virtual Echo? Algorithm # Iterations Time No IST / pl5 0 60:00 No IST / pl6 0 00:50 No License Required Yes IST 0 00:50 No IRLS 0 00:40 Yes IRLS 0 00:40 Yes IRLS 2 00:12
8 Non-Uniform Sampling FREE in TopSpin mg/ml Cholesterol Acetate hsqcedetgpsp.3-2k x 1K Algorithm = IRLS ; Virtual Echo = True ; # Iteration = 2 NUS = 12.5% NUS = 6.25% NUS = 3.15% mdd_csniter 2 12 seconds NUS = 3.15% mdd_csniter 8 22 seconds
9 Setting Gradient Parameters gppp Python Program in 3.5pl6 Start with a Parameter Set change to a pulse sequence with new/different gradients
10 New GxP Functionality in TS 3.5pl6 lockdataset Protects the contents of EXPNO and PROCNO against modification, deletion or overwriting Freeze a particular folder, yet sill create a new PROCONO for the same data which can be modified lockdatset is a command can be added to AU programs Most useful in a GxP environment Automatic acquisition & processing in PROCNO 1 Digital signature with the command esign Execution of lockdataset to protect from modifications wrp 2 creates a new PROCNO rep 2 switches to this new PROCNO Further interactive processing if desired
11 New Features In IconNMR Version 5 - TopSpin 3.5
12 Importing A Spreadsheet - Improved/Expanded Options Previously had limited options for importing: o Sample Name o Solvent o Experiment o Originator Information Defined Nomenclature for columns [COL_x]
13 Importing A Spreadsheet - Improved/Expanded Options Additional options available o Experiment # o Parameters to Change Flexible Column Definition o Starting in TS label the column in the Excel sheet, and use that label in ICON
14 Importing A Spreadsheet - Improved/Expanded Options Icon has long been able to AUTOMATICALLY import external setup files when they are copied to a defined directory e.g. C:\bruker\topspinx.x\prog\tmp Easy to set up the process to periodically copy the file to this location Cumbersome to generate the file with the correct format Can now automatically import an Excel file
15 Importing A Spreadsheet - Improved/Expanded Options In TopSpin 3.5 Copy the Excel file to the defined directory e.g. C:\bruker\topspin3.5\prog\tmp The spreadsheet will be automatically imported according to previously defined specifications After import, the sheet will be moved to C:\bruker\topspin3.5\prog\tmp\save Tip do not save as directory from Excel to the \prog\tmp folder. Excel will mark the file as in use and IconNMR cannot move the file away
16 Sample Jet & SampleXpress - Barcode Support Without LIMS System or SampleTrack Directly from GUI and/or EXCEL import Barcode is entered, and sample is placed anywhere in the sample changer
17 Sample Jet & SampleXpress - Barcode Support IconNMR can be configured to use barcode ID s instead of holder numbers!
18 Easy Setup can be even easier Further reduce the options presented to the user, independent of what is set in the configuration for users Still have the traditional experiment table with all options open to the user if desired
19 Other Changes in Icon Configuration - Priority AND Day/Night Priority Enabled No Priority access for an individual user Previously No access to priority or night que TopSpin 3.5 Priority option disabled Still have day/night que options
20 Other Changes in Icon Configuration - Archiving in Multiple Directories Previously only a single directory per user was possible o Each user could have a different one, but only one. Now it is possible to specify multiple directories for each user o Each user can have different and multiple archive locations 1) Save to the spectrometer 2) Archive to a workstation where data can be modified, deleted 3) Archive a back-up copy to a central server where the data is not modified
21 Other Changes in Icon Configuration - Options Now supports secured or authenticated s from a smtp server Option for HTML format for more attractive s Use your own pictures: In the home directory of the user who starts Icon: IconNMR-Mail-Logo.png IconNMR-Mail-Seperator.png
22 Other Changes in Icon Configuration - Web Interface Options Allow users to login with standard ICON passwords No longer have to define manually or not use More options for downloading spectra from the web-page
23 Other Changes in Icon Configuration - Additional Accounting Options Reports can now be broken down by originator items Report output now available in spreadsheet (csv) format
24 Other Changes in Icon Configuration - Import/Export Configuration Same ICON configuration on multiple Instruments Saves/Restores the complete IconNMR configuration to a single.xml file o Back up your ICON configuration o Transfer to a different instrument Assumes that you have the same experiments / parameter sets on each instrument
25 Other Changes in Icon Configuration - Virtual Parameter Sets Old way of creating an experiment for ICON-NMR o Read suitable Bruker parameter set o Modify desired parameters o Check acquisition with xaua o Check processing with xaup o Store the parameter set under a new name (wpar) o Make the new experiment available for selected users To transfer to a different instrument o Copy/paste parameter set <TOPSPINHOME>/exp/stan/nmr/lists/par/user o Run paracon to convert everything (field, routing etc) as necessary for other spectrometer
26 Other Changes in Icon Configuration - Virtual Parameter Sets NEW way. Virtual Parameter Sets o On the Fly modifications to standard Bruker parameter Sets The standard parameter sets are on all Bruker instruments Virtual Parameter set information gets saved with ICON configuration
27 Other Changes in Icon Configuration - Virtual Parameter Sets Copy optimized parameters from one experiment to another in automation
28 Just a Reminder - The Dynamics Center
29 The Dynamics Center - Current version is The Dynamics Center contains a general dynamics part which is FREE to use if a TOPSPIN_1D license is available
30 Copyright 2014 Bruker Corporation. All rights reserved. Innovation with Integrity
IconNMR (>TopSpin 3.0)
IconNMR (>TopSpin 3.0) Dr. Sven Augner Bruker BioSpin, Rheinstetten, Germany Innovation with Integrity How to start an IconNMR set 2 IconNMR Select the respective holder 2x IconNMR Select the disk Base
More informationIconNMR Operating Procedures
IconNMR Operating Procedures Revised: 7-1-2015 This guide provides basic instructions for acquiring NMR spectra using the IconNMR automation program. 1. Insert your sample(s) in the SampleXpress sample
More informationStatut actuel de NUS et APSY
Statut actuel de NUS et APSY Martial PIOTTO Bruker BioSpin, France 30 ème Réunion Utilisateurs 29-30 Novembre 2016 Innovation with Integrity General features of NUS and APSY Techniques that allow to collect
More information2017 Bruker BioSpin Users Meeting IconNMR Update
Innovation with Integrity 2017 Bruker BioSpin Users Meeting IconNMR Update Mark Garvey R&D Software Bruker BioSpin GmbH Hannover 6.-7. November & München 8.-9. November 2017 Welcome IconNMR Update IconWEB
More informationInstalling TopSpin 4
Installing TopSpin 4 Note: the screenshots in this guide are from the Windows installation. The Mac installation should be similar, but you must follow the prompts carefully. Start 1. Make an account with
More informationBrief IconNMR and Topspin 3.5 User Guide for Bruker NMR Spectrometers Avance IIIHD 400MHz NMR with Autosampler in Chemistry room 93 DISCLAIMER
DISCLAIMER Brief IconNMR and Topspin 3.5 User Guide for Bruker NMR Spectrometers Avance IIIHD 400MHz NMR with Autosampler in Chemistry room 93 This document is intended to be a brief, bare-bones user s
More informationAcquiring Data in VnmrJ 4.2A
Acquiring Data in VnmrJ 4.2A Linux Primer Initial Steps Changing Password Disabling Screen Lock Reservations Reservation Terminals Rules and Proper Etiquette System Identification Working with VnmrJ 4.2A
More informationPINMRF. Bruker AV-III / Avance DRX NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy
PINMRF Bruker AV-III / Avance DRX NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy INCLUDING: AV-III-400-HD w/ 5mm BBFO SmartProbe 369 WTHR AV-III-500-HD w/ 5mm BBFO
More informationBruker Avance 400 MHz Instructions
Bruker Avance 400 MHz Instructions General Policy: 1) All users must pass the training course before they will obtain their own access to the spectrometer. 2) A key to Bruker Avance 400 Room is accessible
More informationVNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400
VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400 January 10, 2019 1. Sample preparation a. Tubes of any length can be used b. Make your samples 4 cm deep. They will not shim as well if they are shorter; you
More informationDiffusion Ordered Spectroscopy (DOSY) Overview BRUKER last edit 5/14/12
Diffusion Ordered Spectroscopy (DOSY) Overview BRUKER last edit 5/14/12 DOSY Diffusion Ordered SpectroscopY. NMR diffusion experiments, like DOSY, are used to determine the diffusion coefficients of solute
More informationNMR Data Acquisition and Processing Procedure
NMR Data Acquisition and Processing Procedure Dr. Jianfeng Zhu (Research Officer) Please DO NOT remove from NMR lab! Things to Avoid when Using NMR Lab Here's a list of stuff that I have seen that you
More information1D NMR Training Manual for Operating the Bruker 700 MHz Avance III HD NMR. Spectrometer without the Sample Changer and IconNMR
1D NMR Training Manual for Operating the Bruker 700 MHz Avance III HD NMR Spectrometer without the Sample Changer and IconNMR Scheduling NMR Time: Any use of the 700 MHz NMR spectrometer requires prior
More informationRunning Multiple Experiments on the Same Sample Automatically. (multizg, spooler/queue, iconnmr)
Running Multiple Experiments on the Same Sample Automatically (multizg, spooler/queue, iconnmr) Multiple Experiment Setup If you have one sample that requires full characterization (e.g. 1 H, 13 C, COSY,
More informationBruker AVANCE III HD 400 MHz Spectrometer Operation
Bruker AVANCE III HD 400 MHz Spectrometer Operation The spectrometer is located in Room 312 of Physical Sciences I. It is equipped with a SampleXpress sample changer for full automation. To utilize the
More informationDCIF NMR Training Guide 400 MHz Bruker DRX B401 Bruker DPX B400
1 DCIF NMR Training Guide 400 MHz Bruker DRX B401 Bruker DPX B400 400: The Bruker DPX 400 has a broadband probe with 1 H Channel and X-Channel tunable from (30-300 MHz). Both Channels may be tuned researchers.
More informationIconNMR Automation Interface. Online Reference Guide for TopSpin 4 IconNMR Version 5.1
IconNMR Automation Interface Online Reference Guide for TopSpin 4 IconNMR Version 5.1 Copyright (c) 2017 by Bruker BioSpin GmbH All rights reserved. No part of this publication may be reproduced, stored
More informationBruker Topspin NMR Training Manual
Bruker Topspin NMR Training Manual Rev 180521 Perry Pellechia University of South Carolina NMR Facility Subject Page Number Overview of Operation... 1 Gauging Samples in Spinners... 2 Starting and logging
More informationVanderbilt Small Molecule NMR Center
Vanderbilt Small Molecule NMR Center Instructions for Using TOPSPIN version 2.0 DRX 400: Setting up 1H, 13C (1H decoupled), and 31P NMR Experiments Getting started: Sample Preparation: Make sure your sample
More informationShort instructions for the basic operation of the AVANCE II 400 MHz Bruker NMR Using ICON-NMR (PS751)
Dissimilar This manual is intended to be only a very brief introduction for using the Bruker 400 MHz NMR spectrometer (PS751) at the California State University LA NMR Facility. For complete information
More informationTopSpin QuickStart. Default State TopSpin should be running at all times. If this is not the case, you may need to Log In and Start TopSpin.
TopSpin QuickStart Preliminaries Sign Up Sign up for instrument time at calendar.yahoo.com/hmcnmr The password is nmr. During the summer, 1100-1200 and 1600-1700 are reserved for walk-on use (15 min maximum
More informationGoals of tutorial. Introduce NMRbox platform
Introduce NMRbox platform Goals of tutorial Showcase NMRbox with NUS tools A dozen different NUS processing tools installed and configured more coming. Demonstrate potential of NMRbox Now that the platform
More informationQuick Guide to Topspin
Quick Guide to Topspin 1. Log into the workstation. Right mouse click on the desktop anywhere and select new terminal. Type topspin [enter] (if this fails, create the launcher as described next). Alternatively,
More informationT 1 Relaxation Measurement: The Inversion-Recovery Experiment (Using IconNMR) Revised
T 1 Relaxation Measurement: The Inversion-Recovery Experiment (Using IconNMR) Revised 4-21-2015 Relaxation times are divided into two types: longitudinal, which concerns change in magnetization along the
More informationVNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400 AND VARIAN VNMRS 500
VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400 AND VARIAN VNMRS 500 August 9, 2016 1. Sample preparation a. Tubes of any length can be used b. Make your samples 4 cm deep. They will not shim as well if they
More informationDCIF NMR Training Guide 401 MHz Bruker AVANCE III HD b401 last edit 3/11/2015
DCIF NMR Training Guide 401 MHz Bruker AVANCE III HD b401 last edit 3/11/2015 The Bruker AVANCE III HD 401 has a broadband (BBO) probe with a 1 H Channel and X-Channel tunable from (30-300 MHz). Both channels
More informationDCIF NMR Training Guide 400 MHz Bruker AVANCE III HD b400 last edit 3/9/2015
DCIF NMR Training Guide 400 MHz Bruker AVANCE III HD b400 last edit 3/9/2015 The Bruker AVANCE III HD 400 has a broadband (BBO) probe with a 1 H Channel and X-Channel tunable from (30-300 MHz). Both channels
More informationKJM Proton T1 Spectra on the AVI-600 and AVII-600. Version 1.0
KJM 9250 Proton T1 Spectra on the AVI-600 and AVII-600 Version 1.0 Professor Emeritus Alistair Lawrence Wilkins, University of Waikato, New Zealand. February 2018 Proton T1 Spectra on the AVI-600 and AVII-600
More informationTOPSPINPLOT(XWINPLOT)
Mississippi NMR Workshop TOPSPINPLOT(XWINPLOT) Easy and Simple Plotting Written by: Mike Brown Version 01092006.meb Bruker South Training Center Topics Covered Definitions Starting XWINPLOT Layouts Plot
More informationVNMRJ 4.2 INSTRUCTIONS: QANUC 500 FOR CHEMISTS
VNMRJ 4.2 INSTRUCTIONS: QANUC 500 FOR CHEMISTS April 16, 2018 1. Sample preparation a. Tubes of any length can be used b. Make your samples 4 cm deep. They will not shim as well if they are shorter; you
More informationFOCUS. Image Based Automatic Shimming Using B 0 Gradients. Installation and Users Guide Version 0.9
FOCUS Image Based Automatic Shimming Using B 0 Gradients Installation and Users Guide Version 0.9 FOCUS - Field Optimization by Computed Update of Shims Joost A. B. Lohman, Bruker Spectrospin ltd, U.K.
More informationProcessing data with Bruker TopSpin
Processing data with Bruker TopSpin This exercise has three parts: a 1D 1 H spectrum to baseline correct, integrate, peak-pick, and plot; a 2D spectrum to plot with a 1 H spectrum as a projection; and
More informationBruker NMR Topspin Manual
Bruker NMR Topspin Manual Topspin is an icon driven software package. This means that instead of reading words and typing commands in the software most of the things will be carried out by clicking icons
More informationUC DAVIS NMR FACILITY BRUKER SHORT MANUAL FOR TOPSPIN 3.X
TABLE OF CONTENTS UC DAVIS NMR FACILITY BRUKER SHORT MANUAL FOR TOPSPIN 3.X VERSION 3 February, 2016 Disclaimer... 2 Conventions... 2 Routine 1D NMR Experiments Procedure for acquiring 1D Proton spectrum...
More informationTopSpin is the successor to a program called XWinNMR, which appeared in the mid- 90s (I believe) and was used to run Bruker spectrometers until it
1 2 TopSpin is the successor to a program called XWinNMR, which appeared in the mid- 90s (I believe) and was used to run Bruker spectrometers until it was replaced by TopSpin in 2005 or so. While much
More informationSee XwinNMR Acquisition Manual, Sections 1.4, 1.5 (see list of acquistion parameter descriptions starting , pg. A-39), 1.6
Bruker Avance360 X-Nucleus Experiments Page 13 III. X-Nucleus Acquisitions Example Session See XwinNMR Acquisition Manual, Sections 1.4, 1.5 (see list of acquistion parameter descriptions starting 1.5.2.4,
More informationRoutine 1 H and 13 C NMR Data Acquisition Basic Topspin Processing Guide For PSC and NSC Bruker 400 NMR Spectrometer
Routine 1 H and 13 C NMR Data Acquisition Basic Topspin Processing Guide For PSC and NSC Bruker 400 NMR Spectrometer Dr. Zhenming Du Email: zdu@gsu.edu Phone: 3-5538 Revised 04/02/2015 LC=Left click; DC=double
More informationWelcome to the NMR Center
1 Welcome to the NMR Center The NMR center in chemistry consists of six Bruker NMR instruments Field/Name Location Comments Operating Software 300nb (narrow bore) 119 Havemeyer walk-on, routine 1 H Topspin
More informationGoals of tutorial. Showcase NMRbox with NUS tools A dozen different NUS processing tools installed and configured more coming.
Introduce NMRbox platform Goals of tutorial Showcase NMRbox with NUS tools A dozen different NUS processing tools installed and configured more coming. Demonstrate potential of NMRbox Now that the platform
More informationMNova Version Installation Instructions.
MNova Version 12.0.0 Installation Instructions. Note: This Document contains information for a new NMR user. Carefully read and accomplish each section before moving to the next. If you can t finish a
More informationInstallation Procedure and Registration
Metrology Xplorer@ 1 Report Updater This package includes an optional Report Format tool for Metrology Xplorer 1.2 (METEX1). METEX1 has the ability to display Crystal Reports, but the report format is
More informationCOMPUTER BASICS LESSON 4 COMPUTER OPERATION SYSTEMS. Edited by C. 1Rhodes 9/11
COMPUTER BASICS LESSON 4 COMPUTER OPERATION SYSTEMS Edited by C. 1Rhodes 9/11 ESSENTIAL STANDARD Computer Basics ESSENTIAL QUESTIONS What are the parts and features of a computer? What are the functions
More informationJK Archives Web Portal Reference Guide
JK Archives Web Portal Reference Guide 44077 Mercure Circle Sterling, VA 20166 703 754 6735 request@jkmoving.com 1 P age JK Archives Web User s Guide JK Archives uses the Total Recall SQL Records Management
More informationView my bill online. User guide
View my bill online User guide View my bill online With View My Bill Online, you can monitor the conferencing charges to your account anytime from anywhere. It s easier than ever to get the charge details
More informationKJM NMR processing everywhere with Windows Remote Desktop and TopSpin 3.5 at nmr-server.uio.no. Windows Server Version 1.
KJM 5280 V NMR processing everywhere with Windows Remote Desktop and TopSpin 3.5 at nmr-server.uio.no Windows Server 2012 Version 1.4 F. Rise May 2018 1 Nmr-server.uio.no is the final destination for all
More informationTopSpin. Acquisition Commands and Parameters. Innovation with Integrity. Version 003 NMR
TopSpin Acquisition Commands and Parameters Version 003 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval
More informationTopSpin. Release Letter User Manual. Innovation with Integrity. Version 007 NMR
TopSpin Release Letter 3.5.7 User Manual Version 007 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval
More informationHow to Export a Report in Cognos Analytics
IBM Cognos Analytics How to Export a Report in Cognos Analytics Reports viewed in IBM Cognos Analytics can be exported in many formats including Excel. Some of the steps for exporting are different depending
More informationCHEMISTRY DEPARTMENT Category Work Instruction
No. of pages: 1 of 10 1. PURPOSE The purpose of this procedure established is to provide clear instructions for steps or orders on how to run sample analysis using JEOL NMR ECX 400MHz SYSTEM JOEL equipment.
More information1D and 2D Experiments Step-by-Step Tutorial
1D and 2D Experiments Step-by-Step Tutorial Basic Experiments User Guide Version 004 The information in this manual may be altered without notice. BRUKER BIOSPIN accepts no responsibility for actions taken
More informationLogin Accessing AECOM ProjectWise. Table of Contents. 1.0 Login Account Types AECOM Accounts AECOMONLINE Accounts. 2.0 Datasources
Login Accessing AECOM ProjectWise Table of Contents 1.0 Login Account Types AECOM Accounts AECOMONLINE Accounts 2.0 Datasources 3.0 ProjectWise Explorer Login 4.0 Integrated Software Login 1.0 Login Account
More informationUsing the New UCOP UAT Validation Reports For Undergraduate Admissions
To access the new UAT validation reports in Cognos for Course Enrollment data, please follow the instructions outlined below: 1. Copy and paste the following link into your browser - http://data.ucop.edu.
More informationAVANCE IVDr. IVDr Data Browser User Manual. Innovation with Integrity. Version 001 NMR
AVANCE IVDr IVDr Data Browser User Manual Version 001 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval
More informationRemoteMRC. Introduction Connecting to a Workstation Connecting to a Workstation Terminal Troubleshooting... 9
RemoteMRC Contents Introduction... 2 Connecting to a Workstation... 3 Connecting to a Workstation Terminal... 8 Troubleshooting... 9 Outside of Network... 10 Gray Screen with White Prompt after Connecting...
More informationTable of Contents. Navigate the Management Menu. 911 Management Page
ucontrol Managing 911 Information Important note regarding 911 service: VoIP 911 service has certain limitations relative to Enhanced 911 service that is available on most traditional telephone service.
More informationMT Thymidine, [methyl- 3 H]- Lot A THN
MT-6036 Thymidine, [methyl- 3 H]- Lot 846-160-065-A-20110826-THN A) All chromatograms were run using the HPLC method described on the Product Data Sheet. Concentrations and volumes: Standard solution concentration
More informationGet More Out of Google
Get More Out of Google (317) 885-5036 questions@greenwoodlibrary.us www.greenwoodlibrary.us This course will cover free Google tools beyond searching and Gmail. You will be introduced to Google Docs, Drive,
More informationNMR FACILITY DEPARTMENT OF CHEMISTRY University of Washington TOPSPIN 2.1 TRAINING NOTES
NMR FACILITY DEPARTMENT OF CHEMISTRY University of Washington TOPSPIN 2.1 TRAINING NOTES February 2011 rajan paranji CONTENTS Introduction 3 View of TOPSPIN INTERFACE 6 Operating the Bruker Spectrometer
More informationDoc. Version 1.0 Updated:
OneStop Reporting Report Publisher 3.5 User Guide Doc. Version 1.0 Updated: 2012-01-02 Table of Contents Introduction... 3 Who should read this manual... 3 What s included in this manual... 3 Symbols and
More informationTopSpin. TopSpin User Manual. Innovation with Integrity. Version 003 NMR
TopSpin TopSpin User Manual Version 003 Innovation with Integrity NMR Copyright by Bruker Corporation All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or
More informationSalesCTRL Release Notes
Task Manager Redesign screen Increase Task Name to 20-characters and Description to 40-characters Add Folder and Sub-Folders to organize Tasks Add tree-view look up for Tasks and Actions Add Email Library
More informationMCC Client Communicator User Manual
MCC Client Communicator User Manual Logging in The login page can be accessed at https://adfeathers.appspot.com/mcc.html or use the link included in the email you received with your login information.
More informationLearning FirstClass. Do not save your password in the password box. If it is saved there, anyone can gain access to your at any time.
Learning FirstClass A. Setting up the program Install the program and the setup window will open. Fill in the server information mail.ccsd.k12.wy.us The user id may be filled in also. Click Save. Do not
More informationWEBppliance for Windows User Administrator's Help
WEBppliance for Windows User Administrator's Help September 23, 2003 Contents About This Document...3 How to use this Help system...4 Getting started...6 What to do first... 6 Viewing your account settings...
More informationIntroduction to Cognos
Introduction to Cognos User Handbook 7800 E Orchard Road, Suite 280 Greenwood Village, CO 80111 Table of Contents... 3 Logging In To the Portal... 3 Understanding IBM Cognos Connection... 4 The IBM Cognos
More informationNMR FACILITY DEPARTMENT OF CHEMISTRY University of Washington XWINNMR 3.5 TRAINING NOTES. 08/8/2005 rajan paranji
NMR FACILITY DEPARTMENT OF CHEMISTRY University of Washington XWINNMR 3.5 TRAINING NOTES 08/8/2005 rajan paranji CONTENTS Views of XWINNMR INTERFACE 4 Operating the Bruker Spectrometer FLOW CHART 5 LOGON
More informationJob BASE by Spectrum CNC Technologies
Job BASE by Spectrum CNC Technologies Job BASE is a Production Document Management system. CNC Programs, Offset Files, CAD Drawings, Wire frame, 3D Solid Models, Setup Sheets, Tool Lists and other production
More informationUNIVERSAL SOFTWARE. Universal Software. Data Sheet
Universal Software Data Sheet System Requirements: The minimum requirements for using the Software are: 1). Windows XP/Vista/7 2). A minimum of 512 MB RAM 3). 1 GB of hard disk space 4). Microsoft Office
More informationToday s Training Agenda. MMS website: FMAX website: https://test.mms.indiana.edu/fmax-stg
MMS Today s Training Agenda MMS website: http://www.indiana.edu/~mmswebpg/ FMAX website: https://test.mms.indiana.edu/fmax-stg Scott Knapp Administrator of MMS scknapp@indiana.edu 812-855-5826 Navigation
More informationTraceFinder Analysis Quick Reference Guide
TraceFinder Analysis Quick Reference Guide This quick reference guide describes the Analysis mode tasks assigned to the Technician role in the Thermo TraceFinder 3.0 analytical software. For detailed descriptions
More informationInstall & Configure Thunderbird E- mail
Install & Configure Thunderbird E- mail Thunderbird is a free, open source mail client that runs on Windows, Mac, and Linux. This document will cover specific information about setting up Thunderbird 2
More informationMC Lot A MW
MC-2302 N 6 -Benzyladenine, [benzyl ring- 14 C]- Lot 195-057-060-A-20100308-MW A) All chromatograms were run using the HPLC method described on the Product Data Sheet. Concentrations and volumes: Standard
More informationOutlook Web App (Exchange 2010) User Guide Computer Training Solutions Version Revision Date
Outlook Web App (Exchange 2010) Computer Training Solutions Version 1.7 Revision Date 2014-December-1 Table of Contents QUICK REFERENCE... 2 OUTLOOK WEB APP URL... 2 MANITOBA EHEALTH SERVICE DESK... 2
More informationtesto Comfort Software CFR 4 Instruction manual
testo Comfort Software CFR 4 Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Specifications... 4 2.1. Intended purpose... 4 2.2. 21 CFR Part 11 and terminology used... 5 3 First steps... 9
More informationUniversity of Massachusetts Amherst * Boston * Dartmouth * Lowell * President s Office * Worcester
Running Queries Users can access the Query Viewer to run pre-defined queries. The results of these queries will aid and assist in statistical analysis and decision making. This job aid explains the procedure
More informationDelta V5 operation. Widetron Technologies Corp. Wu, Chung Ying. Progress through Synergy
Delta V5 operation Widetron Technologies Corp. Wu, Chung Ying Connect to spectrometer 1. Start Delta V5 (double click ). 2. Open Spectrometer Control (click ). 3. Select spectrometer on Available Instruments.
More informationUser Guide EDDIE. Enterprise Data Delivery Information Environment. Business Objects 4.1
User Guide EDDIE Enterprise Data Delivery Information Environment Business Objects 4.1 2 P a g e EDDIE 4.1 User Guide Contents Introduction to EDDIE... 4 Log into EDDIE... 4 Overview of EDDIE Homepage...
More informationOnline Access: Login to The Media Audit
Online Access: Login to The Media Audit Using The Media Audit online has never been easier! Simply open your web browser and follow the quick instructions below. app.themediaaudit.com Open your favorite
More informationFluorimeter User s Booklet
Fluorimeter User s Booklet 1) Verify that the instrument power and the computer are both off. Then turn on the lamp. The red indicator light will glow when the lamp is on. Turn on lamp switch here. This
More informationBruker Barcode Stand-alone Unit
Bruker Barcode Stand-alone Unit Instruction Manual Version 001 BRUKER The information in this manual may be altered without notice. BRUKER accepts no responsibility for actions taken as a result of use
More informationBruker AVANCE-360 User s Guide for the UWChemMRF
Bruker AVANCE-360 User s Guide for the UWChemMRF by CG Fry last revised: 2004.08.01 Bruker Avance360 Introduction Page 2 UWChemMRF User Guide for XwinNMR I. Introduction... 3 a) Account information...
More information500 MHz Solution-state NMR Procedure. (Bruker AVANCE Machines running TopSpin under WINDOWS XP)
500 MHz Solution-state NMR Procedure (Bruker AVANCE Machines running TopSpin under WINDOWS XP) Jerry Hu, x7914, jghu@mrl.ucsb.edu Shamon Walker, x3248 shamonwalker@mrl.ucsb.edu Materials Research Laboratory
More informationAgilent MassHunter Easy Access Software
Agilent MassHunter Easy Access Software Quick Start Guide Where to Find More Information 3 Installation 4 Sharing Configurations with Multiple Instruments 10 Installed Files 11 Using Easy Access Software
More informationContent. Getting data organized Good data processing Plotting
1 Content Getting data organized Good data processing Plotting 2 Documentation: Software Manuals available in TopSpin Software manuals are accessible from within TopSpin under the icon. A good place to
More informationA dictator may use a digital hand-held recorder for dictation, in lieu of the telephone, which can be uploaded to the Sten-Tel ASP system.
INSTRUCTIONS FOR DICTATION VIA THE ASP WEBSITE Uploading voice files A dictator may use a digital hand-held recorder for dictation, in lieu of the telephone, which can be uploaded to the Sten-Tel ASP system.
More informationPINMRF. Bruker Avance / AV NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy
PINMRF Bruker Avance / AV NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy INCLUDING: Avance DRX500-1 w/ 5mm TBI Probe - 367 WTHR Avance DRX500-2 w/ 5mm BBO or TXI
More informationUniversity of Alaska Statewide Financial Systems User Documentation PROJECT ADMINISTRATION
University of Alaska Statewide Financial Systems User Documentation PROJECT ADMINISTRATION PROJECT ADMINISTRATION Table of Contents 2 Table of Contents Project Administration...3 Project Administration
More informationPlanogram Compliance Checks. This document will show you, step-by-step, how to setup retail planogram compliance checks on VisitBasis.
Planogram Compliance Checks This document will show you, step-by-step, how to setup retail planogram compliance checks on VisitBasis. Step 1 - Have a Product Database Option 1 - Add your products one by
More informationTopSpin 1.3 patch level 10. DPX 200, DPX 300 and DRX 500. Windows XP
KJM 5280 1 H nmr introductory user manual I Version 1.5 TopSpin 1.3 patch level 10 DPX 200, DPX 300 and DRX 500 Windows XP F. Rise May 2018 1 Welcome to the wonderful and amazing world of Nuclear Magnetic
More informationuser s guide for Viabizzuno online
user s guide for Viabizzuno online new Viabizzuno e-business software the first approach with the new system is the authentication form. the first change is already here, the password recovery procedure.
More informationUSER MANUAL FOR. Nano-Checker 710 THE PIONEER AND CONSISTENT INNOVATOR FOR IN VITRO DIAGNOSTICS
USER MANUAL FOR Nano-Checker 710 THE PIONEER AND CONSISTENT INNOVATOR FOR IN VITRO DIAGNOSTICS Read before initial operation Any questions call our technical support line: TABLE OF CONTENTS Chapter Page
More informationImport Manager Application in Compliance 360 Version 2018
Import Manager Application in Compliance 360 Version 2018 Import Manager Application Overview 4 Enhanced Templates 4 Recommendations 5 Import Manager Application (IMA) Security 6 Imports 6 Application
More informationLogic Pro 7.1 Personal Manual by Edgar Rothermich <http://homepage.mac.com/edgarrothermich>
Logic Pro 7.1 File Management (2005-0904) 1 of 9 File Management Logic Pro 7.1 Personal Manual by Edgar Rothermich EdgarRothermich@mac.com File Type Logic uses
More informationProcessing With Topspin
Processing With Topspin Duncan Howe October 31, 2016 Department Of Chemistry University Of Cambridge 1 Introduction Topspin is a pretty vast piece of software and can do many, many things... There s not
More informationMicroStrategy Academic Program
MicroStrategy Academic Program Creating a center of excellence for enterprise analytics and mobility. HOW TO DEPLOY ENTERPRISE ANALYTICS AND MOBILITY ON AWS APPROXIMATE TIME NEEDED: 1 HOUR In this workshop,
More informationGRAPHIC #1. Open . Save
GroupWise GroupWise...1 Open E-mail...2 Save E-Mail...2 Saving Attachments...4 Reply to E-mail...4 Forward Email...5 Add New Contacts...5 Add New Groups...7 Create & Send New Mail...8 Adding Attachments...10
More informationSmart-X Software Solutions SecReport Enterprise User Guide
Smart-X Software Solutions SecReport Enterprise User Guide Table of Contents: WELCOME 4 FEATURES AND CAPABILITIES 5 CONTENTS AND REQUIREMENTS 7 CONTENTS 7 REQUIREMENTS 8 LICENSING AND INSTALLATION 10 EVALUATION
More informationWeb Page Basics. FRSD Elementary Technology Workshop. February Presented by Lisa Stewart, Tammy Gianvito, and Diane Kaufmann
Web Page Basics FRSD Elementary Technology Workshop February 2014 Presented by Lisa Stewart, Tammy Gianvito, and Diane Kaufmann Please save this booklet for future reference. 2 P a g e Notes and Questions
More information1. Right-click the worksheet tab you want to rename. The worksheet menu appears. 2. Select Rename.
Excel 2010 Worksheet Basics Introduction Page 1 Every Excel workbook contains at least one or more worksheets. If you are working with a large amount of related data, you can use worksheets to help organize
More informationTraining Tracker 6. PC Edition. Copyright Computer Directions, LLC
Training Tracker 6 PC Edition Copyright 2014-2016 Computer Directions, LLC Contents What is Training Tracker?... 3 Getting Started... 4 The People Tab... 4 Overview... 4 Adding People... 5 Editing People...
More information