Instruction Manual. External Output Manual. Liquid Scintillation System LSC Model

Size: px
Start display at page:

Download "Instruction Manual. External Output Manual. Liquid Scintillation System LSC Model"

Transcription

1 Instruction Manual External Output Manual Liquid Scintillation System Model LSC-8000 Thank you for purchasing this product. The instruction manual of this product consists of the Operation Manual the External Output Manual (this manual) and the Maintenance and Inspection Manual. In addition the booklet of the Quick Guide is attached. Please read the Operation Manual first. Please read this manual thoroughly before use to ensure correct operation. After reading this manual keep it in a safe place where it can be referred to easily whenever necessary. RN

2 * ** * This instrument complies with Machinery Device Directive 2006/42/EC and EMC Device Directive 2004/108/EC and RoHS Directive 2011/65/EU. ** This instrument complies with Directive 2012/19/EU on waste electrical and electronic equipment (WEEE). Legal Notices (1) Unauthorized reproduction of this manual in whole or part is strictly prohibited. (2) Information and specifications in this manual are subject to change without notice. (3) Although we strive to ensure accuracy of this information if you believe the manual contains errors or omissions please contact us. (4) Hitachi Aloka Medical Ltd. cannot be held liable for consequences of equipment usage whether related or unrelated to errors or omissions in this manual as mentioned in (3) above. (5) Hitachi Aloka Medical Ltd. cannot be held liable for problems arising from the usage of third-party or non-certified optional products or consumables in conjunction with the equipment. (6) Screen descriptions and illustrations in this manual may differ somewhat from actual screens. The equipment uses a Windows system. Microsoft and Windows are trademarks of Microsoft Corporation registered in the U.S. and other countries. Reproduction or modification of this product without authorization from Hitachi Aloka Medical Ltd. is prohibited. 2 RN

3 Hitachi Aloka Medical Ltd. L-166Q A4 RN

4 Before Reading This Manual This is the instruction manual regarding external output from LSC-8000 Liquid Scintillation System. The manual contains important information needed to operate the equipment safely and correctly. Read the manual carefully before using the equipment. Please also read the operation manual thoroughly for details of how to use the system before reading this manual. In particular read the safety precautions in Chapter 1 carefully and use the equipment correctly to ensure safety and optimal performance. Keep this manual in a convenient place for reference as needed when using the equipment. 4 RN

5 Before Reading This Manual Manual Structure This manual is organized as follows. Chapter 1 External Output Overview Chapter 2 RS-232C Output Chapter 3 Output via an Ethernet connection or USB flash drive Chapter 4 External output format RN

6 Before reading this manual Safety Alert Symbols Safety labeling is defined below. Sections of the manual labeled with these symbols and signal words give warnings for equipment safety. Consequences of neglecting to follow the warnings are classified as follows. Please read this information carefully. Symbol Meaning Warning Indicates a hazardous situation which if not avoided may result in serious personal injury or property damage. Caution Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury or property damage. Notice Indicates recommended guidelines that users are urged to follow to avoid equipment damage or wear and to support efficient usage. To identify the nature of the potential damage or injury the signal words described above are presented with the following graphic symbols. Symbol Meaning Operators are warned and cautioned regarding the risk inside the warning sign. Specific risks (in the example at left electric shock) are depicted in warning signs. Prohibited actions are indicated in a prohibition sign. Specific prohibited actions (in the example at left disassembly) are depicted in prohibition signs. Operators are urged to follow the instructions associated with the symbol. Specific instructions (in the example at left equipment grounding) are depicted in advisory signs. Other Symbols Symbol Meaning NO TE Explanatory notes give supplemental related information for reference. 6 RN

7 Contents Chapter 1 External Output Overview Types of External Output External Output Connection Procedure RS-232C Output USB output LAN output External output settings Output during measurement Exporting Measurement Results Chapter 2 RS-232C Output RS-232C Output Format Settings RS-232C Output Format Types Connector RS-232C output data configuration RS1 Format RS2 Format RS3 Format RS-232C Protocol Chapter 3 Output via an Ethernet connection or USB flash drive Output Specifications LAN output settings Output Format Types Folder Naming File Naming Type Type Type Output Data Structure Type Type Type Measurement Data Headings of the data output in LAN or USB output Chapter Type 1 Format Type 2 Format Type 3 Format RN

8 Contents 8 RN

9 Chapter 1 External Output Overview Chapter 1 External Output Overview This chapter describes external output from the equipment. RN Chapter 1 External Output Overview 9

10 Chapter 1 External Output Overview 1-1 Types of External Output You can connect LSC-8000 to other devices to use system's output functions to export measurement data to the devices. Three types of external output are supported: via RS-232C USB and Ethernet. (1) RS-232C Output We also provide the data acquisition software (Code: RPR-LSC-584B) for acquiring viewing and analyzing the measurement data. The measurement data can be exported to a computer running data acquisition software by connecting LSC-8000 to the computer via an RS-232C cable. The data files exported can then be viewed and analyzed using the data acquisition software. (2) USB Output Measurement data can be exported in CSV file format to USB flash drives connected to the system. The data files exported can then be viewed and analyzed using commercially available spreadsheet software. (3) LAN Output Measurement data can also be exported in CSV file format to the shared folders of computers connected to the system via an Ethernet cable. The data files exported can then be viewed and analyzed using commercially available spreadsheet software Types of External Output RN

11 Chapter 1 External Output Overview 1-2 External Output Connection Procedure RS-232C Output Measurement data can be exported to a computer running data acquisition software by connecting the computer to LSC-8000 via an RS-232C cable. Connect an RS-232C cable. Rear view RN External Output Connection Procedure 11

12 Chapter 1 External Output Overview USB output Measurement data can be exported to USB flash drives connected to LSC No additional software is needed. Front view Connect a USB flash drive. Notice Do not connect keyboards mouse devices or other peripherals to the USB port. To avoid infecting LSC-8000 with computer viruses do not use USB flash drives that have been connected to computers which were not protected from viruses External Output Connection Procedure RN

13 Chapter 1 External Output Overview LAN output Measurement data can be exported to the shared folders of computers connected to LSC-8000 via an Ethernet cable. No additional software is needed. To protect the equipment from the threat of computer viruses limit connections to the local network. For details of Ethernet connection see Section 3-2. Connect an Ethernet cable. Rear view Notice To avoid infecting LSC-8000 with computer viruses connect the system to computers in the following kinds of networks. Computers running antivirus software that are not connected to external networks Computers protected by firewalls to prevent unauthorized access from external networks RN External Output Connection Procedure 13

14 Chapter 1 External Output Overview 1-3 External output settings Data can be exported in two ways: output during measurement or output of measurement results (after measurement). If a password has been set in the system conditions exporting measurement results must be done by users with administrator or registered rights Output during measurement (1) Output during automatic measurement External output during measurement can be configured on the Output Conditions tab of the MyNo. Detailed Settings screen (For details refer to the Operation Manual Section 4-3). 2 Output select 3 Output Timing 4 Print format 5 RS format 6 File Format 7 File Name Input Area 8 OK button 1 Output Conditions 1 Output Conditions Output during measurement can be configured on the Output Conditions tab of the MyNo. Condition Details screen. This tab is available in Custom optional LUMI or α/β mode. The settings cannot be configured in other modes. 2 Output select Select the destination for measurement data. Measurement data is sent to selected output destinations External output settings RN

15 Chapter 1 External Output Overview 3 Output Timing This option is available when you have selected either LAN or USB in 2. As for the timing for exporting data to the selected output destinations you can send the data for each sample or for each group. 4 Print Format Select the print format. To specify a file name select File name and choose the name in the selection box displayed. (For print format setting details refer to the Operation Manual Section 6-8.) 5 RS Format This option is available when you have selected RS in 2. Select the file format when exporting via RS-232C. *RS3 format follows Print Format settings in 4. 6 Output format This option is available when you have selected either LAN or USB in 2. Select the file format when exporting via Ethernet or USB. *Type3 format follows Print Format settings in 4. 7 File name input area This option is available when you have selected either LAN or USB in 2. Specify the file name when exporting via Ethernet or USB. Note that the number of characters available for the file name is determined by the file format selected in 6. Type 1: Up to 6 single-byte characters. Spectrum file names are three characters or less. (If you specify four characters or more the extra characters will be truncated.) Types 2 or 3: Up to 20 single-byte or 10 double-byte characters. (Alphanumeric characters and French or Chinese supported.) * The following characters are illegal characters in Windows. Do not use these characters in file names. ( / : *? " < > ) 8 OK Button When you are finished programming output conditions press the OK button. NO TE The data output during measurement will consist of both cpm dpm data and spectrum data. It is not possible to select just one type. Pressing the STOP button will cancel output for the samples being measured and this data (which is not finished being measured) will not be exported. RN External output settings 15

16 Chapter 1 External Output Overview (2) Output during correction curve measurement External output during measurement when preparing correction curves can be configured on the Output Conditions tab of the Correction Curve Settings screen (For details refer to the Operation Manual Section 5-4-1). 2 Output settings 3 Output Timing 4 Print format 5 RS format 6 File Format 7 File Name Input Area 8 OK button 1 Output Conditions 1 Output Conditions Output during measurement can be configured on the Output Conditions tab of the Correction Curve Condition Settings screen. 2 Output settings Select the destination for measurement data. Measurement data is sent to selected output destinations. 2 Output Timing This option is available when you have selected either LAN or USB in 2. As for the timing for exporting data to the selected output destinations you can send the data for each sample or for each group. 4 Print Format Select the print format. To specify a file name select File name and choose the name in the selection box displayed. (For print format setting details refer to Operation Manual Section 6-8.) External output settings RN

17 Chapter 1 External Output Overview 5 RS Format This option is available when you have selected RS in 2. Select the file format when exporting via RS-232C. Only RS1 is available during measurement to prepare correction curves. 6 Output Format This option is available when you have selected either LAN or USB in 2. Select the file format when exporting via Ethernet or USB. Only Type 1 is available during measurement to prepare correction curves. 7 File Name Input Area This option is available when you have selected either LAN or USB in 2. Specify the file name when exporting via Ethernet or USB. Note that the number of characters available for the file name is determined by the file format selected in 6. Type 1: Up to 6 single-byte characters. Spectrum file names are three characters or less. (If you specify four characters or more the extra characters will be truncated.) * The following characters are illegal characters in Windows. Do not use these characters in file names. ( / : *? " < > ) 8 OK button When you are finished programming output conditions press the OK button. To specify other conditions refer to the Operation Manual Section 5-4 as you continue programming. NO TE Pressing the STOP button will cancel output for the samples being measured and this data (which is not finished being measured) will not be exported. RN External output settings 17

18 Chapter 1 External Output Overview Exporting Measurement Results All sample measurement data is saved on the equipment's internal hard disk. The stored measurement data can be exported to a PC via an Ethernet connection or to a USB flash drive. Data files can be exported using the File management function on the Control/Calibration menu. For details of how to use the file management function refer to the Operation Manual Section 8-9. Pressing the Output button on the File management screen will display a File Output screen. 1. Output button 2. Output format selection area 3. Output data selection area 4. File name input area 5. Output destination selection area 6. OK button 7. Cancel button Select desired items in the Select column and press the Output button. 1. Output button This button becomes available once you have selected at least one item in the Select column. Although multiple items can be selected this increases the time required for output of data files. We recommend selecting no more than five items because other operations are not possible during data file output External output settings RN

19 Chapter 1 External Output Overview 2. Output format Select the file format when exporting via USB or Ethernet. NO TE Only Type 1 output is available for results from preparing correction curves validation normalization and automatic calibration. In this case Types 2 and 3 cannot be specified. If the measurement data with Print format unspecified is exported in the Type3 format the data is exported in the default Print format. 3. Output data Select the type of data file to export via Ethernet or USB. cpm dpm: Spectrum: All: Export only cpm dpm data files without spectrum data files. With this option a smaller amount of data is exported than when exporting all data which enables many data files to be exported in a short period. Export only spectrum data files without cpm dpm data files. Because spectrum files are larger than cpm dpm data files exporting takes some time. Export both cpm dpm data files and spectrum data files. As with the Spectrum option described above exporting will take some time. NO TE If the measurement data of validation normalization or auto calibration is exported Output data cannot be specified. 4. File name Specify the file name when exporting via Ethernet or USB. Note that the number of characters available for the file name is determined by the output type selected in 2. Type 1: Types 2 or 3: Up to 6 single-byte characters. Spectrum file names are three characters or less. (If you specify four characters or more the extra characters will be truncated.) Up to 20 single-byte or 10 double-byte characters. (Alphanumeric characters and French or Chinese supported.) * The following characters are illegal characters in Windows. Do not use these characters in file names. ( / : *? " < > ) 5. Output destination Select the destination for the data files. Select either USB or LAN. (Both destinations cannot be selected at the same time.) 6. OK button Exports data files according to the information specified in steps 2 to Cancel button Discards information specified in steps 2 to 5 and cancels output of data files. RN External output settings 19

20 Chapter 1 External Output Overview External output settings RN

21 Chapter 2 RS-232C Output Chapter 2 RS-232C Output This chapter describes RS-232C output. RN Chapter 2 RS-232C Output 21

22 Chapter 2 RS-232C Output 2-1 RS-232C Output Format Settings The RS-232C output method can be configured from Export in the System conditions on the Control/Calibration menu. RS-232C Setting Item Function Input range Default setting Speed Specify the data transfer speed (baud rate). (Unit: bps) 4800/9600/ Data length Specify the data length. (Unit: bits) 7/8 8 Parity Specify the type of vertical redundancy checking. Even/Odd/None Even Stop bits Specify the stop bit length. (Unit: bits) 1/1.5/2 1 Flow Control Specify the data flow control method. RTS/CTS / None None Specify the communication protocol to use for measurement data. Match the settings used by standard Hitachi Aloka Medical data acquisition software. Soft Handshaking Protocol Output measurement data during the transmission and reception process with the data acquisition software. No-protocol Output measurement data without a transmission and reception process with the data acquisition software. Soft handshaking /No-protocol Soft handshaking RS-232C Output Format Settings RN

23 Chapter 2 RS-232C Output 2-2 RS-232C Output Format Types The RS format type can be selected by selecting RS in the output conditions on the screen for exporting MyNo. conditions. There are three different RS-232C output formats as shown below. RS1 Same output format as used by existing Hitachi Aloka Medical equipment (LSC-7200 LSC-7400 and LSC-LB7) for users of these systems. RS2 For exporting all measurement data and measurement conditions. RS3 For selecting desired parameters of measurement data in RS2 items to export. The order of output can also be freely selected. Selection and order of parameters follows the MyNo. conditions print format settings. NO TE When you plan to export data via RS-232C enter any measurement condition notes using single-byte characters. Be aware that double-byte characters may cause character corruption. RN RS-232C Output Format Types 23

24 Chapter 2 RS-232C Output 2-3 Connector Use an RS-232C cable (D-Sub 9-pin female - D-Sub 9-pin female reversed type). Type: D-Sub 9-pin (male) Signals: Pin No Signal RXD TXD SG RTS CTS Caution Do not use pins other than those indicated on the left. Cable: Reverse cable Connection example: 2 2 Equipment side Computer side (9-pin female) (9-pin female) Connector RN

25 Chapter 2 RS-232C Output 2-4 RS-232C output data configuration The data output in RS-232C output will consist of (1) cpm dpm data and (2) spectrum data. Note thatmeasurement data on the Control/Calibration menu such as validation measurement data or automatic calibration measurement data is not output. The configuration of the data output will differ depending on the RS format selected RS1 Format Details of data such as group conditions and measurement data headings follow the Type 1 format. For details see 4-1. (1) cpm dpm data Group Conditions Measurement Data Heading cpm dpm Data (1) cpm dpm Data (2)... Next MyNo. Post Data... cpm dpm Data (n) Group Conditions Measurement Data Heading cpm dpm Data (1) Output When Stopped cpm dpm Data (2) cpm dpm Data (n) Stop Data RN RS-232C output data configuration 25

26 Chapter 2 RS-232C Output (2) Spectrum data Group Conditions Measurement Data Heading cpm dpm Data (1) Spectrum Data Ch. 0 9 Spectrum Data Ch Spectrum Data Ch Spectrum Request Command Next MyNo. Post Data cpm dpm Data (2) Spectrum Data Ch. 0 9 Spectrum Data Ch Group Conditions Measurement Data Heading cpm dpm Data (1) Spectrum Request Output When Stopped Spectrum Data Ch. 0 9 Spectrum Data Ch Spectrum Data Ch Spectrum Data Ch Stop Data NO TE Data begins with an STX code and is terminated with an ETX code. Digit numbers are indicated in parenthesis. Even if half-life correction is selected the cpm dpm and Bq values exported are the values before half-life correction RS-232C output data configuration RN

27 Chapter 2 RS-232C Output Number of data characters for RS1 output format Group Conditions S E T G Type 1: Group Conditions T X X For details of "Type 1: Group Conditions" data see 4-1. RN RS-232C output data configuration 27

28 Chapter 2 RS-232C Output Measurement Data Headings (characters in these structures are exported just as they are) S MyNo. SN RN T T (9) (9) (9) X ESCR or SCCR (9) TIME (9) A-GROSS A-CPM A-DPM or A-Bq (9) (9) (9) A-EFF B-GROSS (9) (9) B-CPM (9) B-DPM or B-Bq B-EFF (9) (9) C-GROSS (9) C-CPM C-DPM or C-Bq (9) (9) C-EFF (9) E SCCR C L T (9) R F X RS-232C output data configuration RN

29 Chapter 2 RS-232C Output cpm dpm Data S E T D Type 1: CPM DPM Data T X X For details of "Type 1: CPM DPM Data" data see 4-1. NO TE cpm dpm Data 1) Data is exported as 204 digits in full. 2) Portions without data are indicated by space. Example: In single-label measurement B- and C-channel data are indicated by spaces. In DATA: CPM DPM or Bq is indicated by spaces. 3) CPM is the net cpm value. 4) Even if half-life correction is selected the CPM DPM and Bq values exported are the values before half-life correction. Spectrum Data S T X S Block No. 1 (3) 0 ch Gross Data (6)... 9 ch Gross Data (6) C R L F E T X S T X S Block No. 2 (3) 10 ch Gross Data (6) ch Gross Data (6) S Block 3990 ch 3999 ch E C L T S No. 400 Gross Data... Gross Data T R F X (3) (6) (6) X C R L F E T X Group Item Description Range Spectrum Data Channels Total count for each channel (0 3999) RN RS-232C output data configuration 29

30 Chapter 2 RS-232C Output Stop Data S E Year/Month/Day Hour C L T E T (10) (5) R F X X / / XX:XX Stop Data Group Item Description Range Year/Month/Day Time Date that measurement was completed (expressed in standard non-japanese format) Time that measurement was completed (expressed in 24-hour format) YYYY/MM/DD (2014/01/31) hh:mm (17:35) RS-232C output data configuration RN

31 Chapter 2 RS-232C Output Exceptions Regarding measurement data headings some items do not correspond directly to cpm dpm data and these are explained below. 1. Standardization: ETM data A-GROSS : Gross count for window W1 (ETM L ch) A-CPM : Count rate for window W1 (ETM L ch) A-ch efficiency : Count efficiency for window W1 (ETM L ch) A-DPM A-Bq B-GROSS B-CPM B-ch efficiency : Gross count for window W2 (ETM L ch) : Count rate for window W2 (ETM L ch) : Count efficiency for window W2 (ETM L ch) C-GROSS : Gross count for window W3 (ETM L ch) C-CPM : Count rate for window W3 (ETM L ch) C-ch efficiency : Count efficiency for window W3 (ETM L ch) 2. Mode: α/β data A-GROSS A-CPM : Gross count for the A-channel window configured in the MyNo. conditions : Count rate for the A-channel window configured in the MyNo. conditions B-GROSS B-CPM : Gross count for the B-channel window configured in the MyNo. conditions : Count rate for the B-channel window configured in the MyNo. conditions C-GROSS C-CPM : Gross count for the C-channel window configured in the MyNo. conditions : Count rate for the C-channel window configured in the MyNo. conditions RN RS-232C output data configuration 31

32 Chapter 2 RS-232C Output RS2 Format Details of data such as group conditions and MyNo.conditions follow the Type 2 format. For details see 4-2. (1) cpm dpm data Group Conditions (Security) MyNo. Conditions cpm dpm Data (1) cpm dpm Data (2)... Next MyNo. Post Data... cpm dpm Data (n) Group Conditions (Security) MyNo. Conditions cpm dpm Data (1) Output When Stopped cpm dpm Data (2) cpm dpm Data (n) Stop Data (2) Spectrum data Group Conditions (Security) MyNo. Conditions cpm dpm Data (1) Spectrum Data Ch. 0 9 Spectrum Data Ch Spectrum Data Ch Spectrum Request Command Next MyNo. Post Data cpm dpm Data (2) Spectrum Data Ch. 0 9 Spectrum Data Ch Group Conditions (Security) MyNo. Conditions cpm dpm Data (1) Spectrum Request Command Output When Stopped Spectrum Data Ch. 0 9 Spectrum Data Ch Spectrum Data Ch Spectrum Data Ch Stop Data NO TE Even if half-life correction is selected the CPM DPM and Bq values exported are the values before half-life correction RS-232C output data configuration RN

33 Chapter 2 RS-232C Output Number of data characters for RS2 output format Group Conditions (Security) S E T G Type 2: Group Conditions (Security) T X X For details of "Type 2: Group Conditions (Security)" data see "4-2 Type 2 Format". MyNo. Conditions S E T M Type 2: MyNo. Conditions T X X For details of "Type 2: MyNo. Conditions" data see "4-2 Type 2 Format". cpm dpm Data S E T D Type 2: CPM DPM data T X X For details of "Type 2: CPM DPM Data" data see "4-2 Type 2 Format". Spectrum Data The same as for "4-1 Type 1 Format (4) Spectrum Data". Stop Data The same as for "4-1 Type 1 Format (4) Stop Data". RN RS-232C output data configuration 33

34 Chapter 2 RS-232C Output RS3 Format Details of data such as group conditions and MyNo.conditions follow the Type2 format. Cpm dpm data output parameters and order follow the Print format specified in MyNo. conditions. The data configuration follows Type3 format RS-232C output data configuration RN

35 Chapter 2 RS-232C Output 2-5 RS-232C Protocol The RS-232C output protocol can be configured in Export in the System conditions on the Control/Calibration menu. For details see 2-1 or the Operation Manual Section 8-5-1(7). The following sequence is used for the output timing of non-protocol and handshake protocol. Non-Protocol Handshake LSC PC LSC PC Group Conditions Data Request Command Measurement Data Headings Group Conditions ACK ACK Data Request Command Measurement ACK 1. Measurement is initiated with Start and when an ID post (MyNo. post) is received group conditions are exported. 2. When handshake protocol is used after ACK is sent a data request or cancel command is sent to the LSC within 3 seconds. In the case of a cancel command go to (6) or return to (1). 3. Headings are exported before measurement of the first sample. cpm dpm Data Ch 1 10 Spectrum Data Ch Spectrum Data cpm dpm Data cpm dpm Data ACK Ch 1 10 Spectrum Data ACK Ch Spectrum Data ACK cpm dpm Data ACK 4. When the first measurement is finished cpm dpm data is exported. In reply to a spectrum data request command spectrum data is exported after the cpm dpm data in 10-channel increments. 5. Cpm dpm data continues to be exported after each measurement until the next ID post (MyNo. post) is received. When this post is received group conditions are exported. (Return to step 1.) Stop Data Stop Data ACK 6. When measurement is stopped the stop data is exported. Data Request Command S T X D C R L F E T X Spectrum Request Command S T X S C R L F E T X RN RS-232C Protocol 35

36 Chapter 2 RS-232C Output Control Codes Item STX ETX ACK LF CR NAK Value 0x02 0x03 0x06 0x0a 0x0d 0x15 ACK (1 byte) A C K NAK (1 byte) N A K NO TE RS-232C output is possible for automatic measurement only. Data produced from manual or interrupted measurement is not exported. If a power outage occurs during measurement after power is restored RS-232C output stops until the next MyNo. post is read. If interrupted measurement is performed during automatic measurement the sample for which measurement was interrupted is measured again. RS-232C output also resumes with the first repeated measurement RS-232C Protocol RN

37 Chapter 3 Output via an Ethernet connection or USB flash drive Chapter 3 Output via an Ethernet connection or USB flash drive This section describes how to export data files via an Ethernet connection or a USB flash drive. RN Chapter 3 Output via an Ethernet connection or USB flash drive 37

38 Chapter 3 Output via an Ethernet connection or USB flash drive 3-1 Output Specifications (1) USB Output Code Output destination CSV format (ASCII code) Exported to a USB flash drive inserted in the equipment (2) LAN Output Code Output destination CSV format (ASCII code) Exported to a shared folder on a dedicated computer connected via an Ethernet cable Output Specifications RN

39 Chapter 3 Output via an Ethernet connection or USB flash drive 3-2 LAN output settings Settings for the computer and network to use can be edited in Export in the system conditions. 1 Remote PC name 2 User name 3 Password 4 Network Settings button 5 Check button 1 Remote PC name Select the destination folder for exporting files via Ethernet. Example: PC name: Destination folder: 02-rbe-pub09 LSC rbe-pub09 LSC-8000 Two characters are added. One character is added between the PC name and destination folder. NO TE Select a shared folder as the destination folder. Set the "Access permission" for the shared folder from "Full control" to "Permitted." 2 User name Specify the user name (log-in ID) for the PC connected via Ethernet. 3 Password Specify the password for the PC connected via Ethernet. The password is hidden by asterisks for security. RN LAN output settings 39

40 Chapter 3 Output via an Ethernet connection or USB flash drive 4 Network Settings button Sets the system network. (1) Workgroup name (2) LAN port (3) OK button (4) Cancel button (1) Workgroup name Specify the workgroup name. The default setting is "ALOKA-LSC". (2) LAN port Specify the IP address subnet mask and default gateway. The default settings are as shown below. IP address setting: Use the following IP address IP address: Subnet mask: Default gateway: Not used. NO TE The IP address for the system must be different from the IP address set for the PC connected via Ethernet. A connection error will occur if they are identical LAN output settings RN

41 Chapter 3 Output via an Ethernet connection or USB flash drive (3) OK button Updates the information specified in steps 1 2 and returns to the previous screen. (4) Cancel button Cancels the settings and returns to the previous screen. 5 Check button Confirms the connection to the destination folder specified in step 1. The screen shown below is displayed once a connection is established. The screen shown below is displayed if connection fails. Check the settings in steps 1 to 4 and the settings for the PC connected via Ethernet. NO TE Network checking sometimes takes few minutes. RN LAN output settings 41

42 Chapter 3 Output via an Ethernet connection or USB flash drive 3-3 Output Format Types The output format type can be selected by selecting LAN or USB in the output conditions on the screen for exporting MyNo. conditions. There are three different data output formats as shown below. Type1 Same output format as used by existing Hitachi Aloka Medical equipment (LSC-7200 LSC-7400 and LSC-LB7) for users of these systems. Type2 For exporting all measurement data and measurement conditions. Type3 For selecting desired parameters of measurement data in Type 2 items to export. The order of output can also be freely selected. Selection and order of parameters follows the MyNo. conditions print format settings Output Format Types RN

43 Chapter 3 Output via an Ethernet connection or USB flash drive 3-4 Folder Naming Outputted file will be stored in the folder for each group. Folder name is created in the following format using the start date and time. (Date and time read the MyNo. post) YYYYMMDDhhmmss Example: Year Month Day Hour Minute Second NO TE Outputted data of the correction curve in the automatic calibration will be distributed to the folder in each nuclide. Nuclide name is granted at the end of the folder name. Example: In the case of H H (H is given to last) Correction curve H H-LOW C C-LOW H+C Character given H HLOW C CLOW HC RN Folder Naming 43

44 Chapter 3 Output via an Ethernet connection or USB flash drive 3-5 File Naming Type 1 (1) cpm dpm data When Data is selected under File in the measurement conditions cpm dpm data files are created for each MyNo. number and cycle. Data File Name D0 xxxxxx. Serial number appended that increases for each measured cycle starting at 001 (Range: 001 to After the count returns to 001 overwriting any files with this name data is stored in one folder.) File name as specified in File Name (maximum 6 alphanumeric characters) Unique code representing cpm dpm data (2) Spectrum data When Spectrum is selected under File in the measurement conditions spectrum data files are created for each count (or repeated measurement). Spectrum File Name S0 xxx. Serial number appended that increases for each repetition of measurement starting at 001 (Range: 001 to After the count returns to 001 overwriting any files with this name data is stored in one folder.) Sample No. (000 to 020 with 000 being a background sample) File name as specified in File Name (maximum 3 alphanumeric characters) Unique code representing spectrum data File Naming RN

45 Chapter 3 Output via an Ethernet connection or USB flash drive (3) Calibration Data Calibration data is exported for the following corrected measurement. Measurement to prepare correction curves Validation measurement Normalization measurement Auto calibration measurement Calibration data files are named as follows. X0 xxxxxx. Unique extension for each type of calibration File name as specified in File Name in the MyNo. measurement conditions (maximum 20 single-byte or 10 double-byte characters (Alphanumeric characters and French or Chinese supported.)) Unique code representing calibration data. A unique code for each type of calibration measurement. Calibration Measurement Code Extension Measurement to prepare correction curves C0 CAL Validation measurement V0 VALI Normalization measurement N0 NORM Auto calibration measurement A0 ACAL Post Name Post No. Correction curve post 60 Validation post 64 Normalization post 65 Automatic calibration post 66 NO TE a. If the maximum allotted characters are not used for the file name 0 is appended to fill in the extra spaces. b. If no USB flash drive is inserted in the USB port or if there are file problems at the destination where files will be saved over Ethernet an error message is displayed (A file output error has occurred). However measurement continues even in this case. c. If interrupted measurement is performed during automatic measurement the sample for which measurement was interrupted is measured again. The data to be exported as a file is also exported starting with the first repeated measurement after data from before interruption (the same file). RN File Naming 45

46 Chapter 3 Output via an Ethernet connection or USB flash drive Type 2 (1) cpm dpm data When Data is selected under File in the measurement conditions cpm dpm data files are created for each MyNo. number and cycle. Data File Name D0 xxxxxx. (2) Spectrum data Serial number appended that increases for each measured cycle starting at 001 (Range: 001 to After the count returns to 001 overwriting any files with this name data is stored in one folder.) File name as specified in File Name in the MyNo. measurement conditions (maximum 20 single-byte or 10 double-byte characters (Alphanumeric characters and French or Chinese supported.)) Unique code representing cpm dpm data When Spectrum is selected under File in the measurement conditions spectrum data files are created for each count (or repeated measurement). Spectrum File Name S0 xxx. Serial number appended that increases for each repetition of measurement starting at 001 (Range: 001 to After the count returns to 001 overwriting any files with this name data is stored in one folder.) Sample No. (000 to 020 with 000 being a background sample) File name as specified in File Name in the MyNo. measurement conditions (maximum 20 double-byte or 10 single-byte characters (Alphanumeric characters and French or Chinese supported.)) Unique code representing spectrum data File Naming RN

47 Chapter 3 Output via an Ethernet connection or USB flash drive Type 3 The same as for "3-5-2 Type 2". RN File Naming 47

48 Chapter 3 Output via an Ethernet connection or USB flash drive 3-6 Output Data Structure The data output in LAN or USB output will consist of (1) cpm dpm data (2) spectrum data and (3) calibration data. The data structure for the individual output formats is as follows Type 1 (1) cpm dpm data Group Conditions Measurement Data Heading cpm dpm Data (1) cpm dpm Data (2) cpm dpm Data (n) E O F (2) Spectrum data Group Conditions Measurement Data Heading cpm dpm Data (1) Channel Spectrum Data E O F The format of group conditions measurement data headings cpm dpm data and spectrum data corresponds to the format of STX + data type + "" (without ETX) in RS-232C output. Refer to Section Measurement Data Heading. For details of each format see chapter 4. (3) Calibration Data Calibration data is exported for the following corrected measurement. Measurement to prepare correction curves Validation measurement Normalization measurement Auto calibration measurement Calibration Group Conditions Calibration Data E O F NO TE Even if half-life correction is selected the CPM DPM and Bq values exported are the values before half-life correction. Outputs the value before half-life correction Output Data Structure RN

49 Chapter 3 Output via an Ethernet connection or USB flash drive Type 2 (1) cpm dpm data Group Conditions (Security) MyNo. Conditions cpm dpm Data (1) cpm dpm Data (2) cpm dpm Data (n) E O F (2) Spectrum data Group Conditions (Security) MyNo. Conditions cpm dpm Data (1) Channel Spectrum Data E O F The format of group conditions measurement data headings cpm dpm data and spectrum data corresponds to the format of STX + data type + "" (without ETX) in RS-232C output. For details of each format see chapter 4. NO TE Even if half-life correction is selected the CPM DPM and Bq values exported are the values before half-life correction Type 3 The same as for "3-6-2 Type 2". RN Output Data Structure 49

50 Chapter 3 Output via an Ethernet connection or USB flash drive Measurement Data Headings of the data output in LAN or USB output. Characters in these structures are exported just as they are. The format of automatic measurement corresponds to the format of STX + data type + "" (without ETX) in RS-232C output. Correction Curves SN (2) ESCR (4) SCCR (4) TIME (4) A-GROSS (7) A-CPM (5) A-EFF (5) A-DPM (5) B-GROSS (7) B-CPM (5) B-EFF (5) B-DPM (5) C-GROSS (7) C-CPM (5) C- EFF (5) C-DPM (5) B/A (3) C/A (3) C/B (3) NOTE (4) C R L F Output Data Structure RN

51 Chapter 3 Output via an Ethernet connection or USB flash drive Validation SN (2) TIME (4) ESCR (4) H-CPM (5) C-CPM (5) CO-CPM (6) EFF (3) CO-EFF (6) 44 NOTE (4) C R L F RN Output Data Structure 51

52 Chapter 3 Output via an Ethernet connection or USB flash drive Normalization MS (2) SN (2) HV (2) TIME (4) ESCR (4) H-CPM (5) H-EFF (5) C-CPM (5) C-EFF (5) CO-CPM (6) CO-EFF (6) GL-CPM (6) Gamma-CUT (9) Beta-CUT (8) NOTE (4) C R L F Output Data Structure RN

53 Chapter 3 Output via an Ethernet connection or USB flash drive Automatic calibration MS (2) SN (2) RN (2) HV (2) ESCR (4) SCCR (4) TIME (4) A-CPM (5) A-EFF (5) A-DPM (5) B-CPM (5) B-EFF (5) B-DPM (5) B/A (3) CO-GROSS (8) CO-CPM (6) CO-EFF (6) BG-CPM (6) EFF (3) CH (2) NOTE (4) C R L F RN Output Data Structure 53

54

55 Chapter 4 This chapter describes external output format details. RN Chapter 4 55

56 4-1 Type 1 Format Details of the individual data structures for Type 1 Format are as shown below. (1) Group Conditions 1 MyNo. MyNo. 2 Comment 3 Standardization 4 Data 5 Label 6 Repeats 7 Isotope 8 Year/Month/Day 9 Time Notes specified in MyNo. conditions Standardization specified in MyNo. conditions MyNo. measurement conditions data Label specified in MyNo. conditions Specified in MyNo. conditions Repeats Isotope specified in MyNo. conditions Date the post was received (expressed in standard non-japanese format) Time the post was received (expressed in 24-hour format) 1 to VL AC NR 25 single-byte characters 12 double-byte characters * OFF ESCR SCCR ETM AIS A/B A/BESpace CPM DPM BqSpace Single Double Triple Space 1 to If is specified 999 is exported H H-LOW C C-LOW P P(cer I H+C H+C+P F/S F/D F/T - YYYY/MM/DD (2014/01/31) hh:mm (Example:17:35) Text 2 Text 25 Text 4 Text 3 Text 6 Number 3 Text 5 Text 10 Text 5 * Single-byte only if the RS-232C data length is set to 7 bits Type 1 Format RN

57 (2) CPM DPM Data Automatic measurement Correction curves (RS-232C) 1 My No. My No. 1 to Number 2 2 Sample No. Sample No. 0 to 999 Number 3 3 Repeat No. Repeat No. 0 to 999 Number 3 4 ESCR or SCCR ESCR or SCCR values 0.00 to Number 5 5 Blank Blank Space Text 1 6 TIME Measurement time to Number 8 7 A-GROSS A-channel total (gross) counts 0 to Number 7 8 A-CPM A-channel count rate 0.00 to Number 9 9 A-DPM or A-Bq A-channel radioactivity 0.00 to Number 9 10 A-EFF A-channel count efficiency 0.00 to Number 9 11 B-GROSS B-channel total (gross) counts 0 to Number 7 12 B-CPM B-channel count rate 0.00 to Number 9 13 B-DPM or B-Bq B-channel radioactivity 0.00 to Number 9 14 B-EFF B-channel count efficiency 0.00 to Number 9 15 C-GROSS C-channel total (gross) counts 0 to Number 7 16 C-CPM C-channel count rate 0.00 to Number 9 17 C-DPM or C-Bq C-channel radioactivity 0.00 to Number 9 18 C-EFF C-channel count efficiency 0.00 to Number 9 19 SCCR value with ESCR or AIS standardization 20 Year/Month/Day 21 Time 22 Flag 1 SCCR value 0.00 to Number 9 Date that measurement was completed (expressed in standard non-japanese format) Time that measurement was completed (expressed in 24-hour format) Flags shown in the Note column 23 Flag 2 Rack ID relevant to Flag 1 YYYY/MM/DD (2014/01/31) hh:mm (17:35) Warning in case of sample problems Warning in case of sample problems Text 10 Text 5 Text 9 Text 9 RN Type 1 Format 57

58 Correction curves (Ethernet connection or USB flash drive) 1 Sample No. Sample No. 1 to 999 Number 2 ESCR ESCR value 0.00 to Number 3 SCCR SCCR value 0.00 to Number 4 TIME Measurement time to Number 5 A-GROSS A-channel total (gross) counts 0 to Number 6 A-CPM A-channel count rate 0.00 to Number 7 A-EFF A-channel count efficiency 0.00 to Number 8 A-DPM or A-Bq A-channel radioactivity 0.00 to Number 9 B-GROSS B-channel total (gross) counts 0 to Number 10 B-CPM B-channel count rate 0.00 to Number 11 B-EFF B-channel count efficiency 0.00 to Number 12 B-DPM or B-Bq B-channel radioactivity 0.00 to Number 13 C-GROSS C-channel total (gross) counts 0 to Number 14 C-CPM C-channel count rate 0.00 to Number 15 C-EFF C-channel count efficiency 0.00 to Number 16 C-DPM or C-Bq C-channel radioactivity 0.00 to Number 17 B/A Overlapping ratio (B/A) 0.00 to Number 18 C/A Overlapping ratio (C/A) 0.00 to Number 19 C/B Overlapping ratio (C/B) 0.00 to Number 20 Flag 1 Flags shown in the Note column 21 Flag 2 Rack ID relevant to Flag 1 22 Date/Time Date and time that measurement was completed (expressed in standard non-japanese date format and 24-hour time format) Warning in case of sample problems Warning in case of sample problems YYYY/MM/DD hh:mm ( 2014/01/31 17:35 ) Text Text Text Type 1 Format RN

59 Validation 3H Sample 1 Sample No. Sample No. 1 Number 2 TIME Measurement time to Number 3 ESCR ESCR value 0.00 to Number 4 H-CPM Net CPM 0.00 to Number 5 C-CPM None None None 0 6 COIN-CPM Net CPM 0.00 to Number 7 EFF Count efficiency 0.00 to Number 8 COIN-EFF Count efficiency 0.00 to Number 9 Flag 1 Flags shown in the Note column 10 Flag 2 Rack ID relevant to Flag 1 11 Date/Time Date and time that measurement was completed (expressed in standard non-japanese date format and 24-hour time format) Warning in case of sample problems Warning in case of sample problems YYYY/MM/DD hh:mm ( 2014/01/31 17:35 ) Text Text Text 20 RN Type 1 Format 59

60 14C Sample 1 Sample No. Sample No. 2 Number 2 TIME Measurement time to Number 3 ESCR ESCR value 0.00 to Number 4 H-CPM None None None 0 5 C-CPM Net CPM 0.00 to Number 6 COIN-CPM Net CPM 0.00 to Number 7 EFF Count efficiency 0.00 to Number 8 COIN-EFF Count efficiency 0.00 to Number 9 Flag 1 Flags shown in the Note column 10 Flag 2 Rack ID relevant to Flag 1 11 Date/Time Date and time that measurement was completed (expressed in standard non-japanese date format and 24-hour time format) Warning in case of sample problems Warning in case of sample problems YYYY/MM/DD hh:mm ( 2014/01/31 17:35 ) Text Text Text Type 1 Format RN

61 BG Sample 1 Sample No. Sample No. 3 Number 2 TIME Measurement time to Number 3 ESCR ESCR value 0.00 to Number 4 H-CPM Net CPM 0.00 to Number 5 C-CPM Net CPM 0.00 to Number 6 COIN-CPM Net CPM 0.00 to Number 7 EFF None None None 0 8 COIN-EFF None None None 0 9 Flag 1 Flags shown in the Note column 10 Flag 2 Rack ID relevant to Flag 1 11 Date/Time Date and time that measurement was completed (expressed in standard non-japanese date format and 24-hour time format) Warning in case of sample problems Warning in case of sample problems YYYY/MM/DD hh:mm ( 2014/01/31 17:35 ) Text Text Text 20 RN Type 1 Format 61

62 Normalization Gain check 1 Measurement step Measurement step 0 Number 1 2 SN Sample No. 1 Number 3 HV None None None 0 4 TIME Measurement time to Number 5 ESCR ESCR value 0.00 to Number 6 H-CPM Net CPM 0.00 to Number 7 H-EFF Count efficiency 0.00 to Number 8 C-CPM None None None 0 9 C-EFF None None None 0 10 CO-CPM Net CPM 0.00 to Number 11 CO-EFF Count efficiency 0.00 to Number 12 GL-CPM None None None 0 13 γ-cut γ-cut value 0 to 3999 Number 14 β-cut β-cut value 0 to 3999 Number 15 Flag 1 Flags shown in the Note column 16 Flag 2 Rack ID relevant to Flag 1 17 Date/Time Date and time that measurement was completed (expressed in standard non-japanese date format and 24-hour time format) Warning in case of sample problems Warning in case of sample problems YYYY/MM/DD hh:mm ( 2014/01/31 17:35 ) Text Text Text Type 1 Format RN

63 HV calibration (STEP 1) 1 Measurement step Measurement step 1 Number 1 2 SN Sample No. 1 Number 3 HV HV value 0 to 9999 Number 4 TIME Measurement time to Number 5 ESCR None None None 0 6 H-CPM Net CPM 0.00 to Number 7 H-EFF Count efficiency 0.00 to Number 8 C-CPM None None None 0 9 C-EFF None None None 0 10 CO-CPM Net CPM 0.00 to Number 11 CO-EFF Count efficiency 0.00 to Number 12 GL-CPM None None None 0 13 γ-cut None None None 0 14 β-cut None None None 0 15 Flag 1 None None None 0 16 Flag 2 None None None 0 17 Date/Time Date and time that measurement was completed (expressed in standard non-japanese date format and 24-hour time format) YYYY/MM/DD hh:mm ( 2014/01/31 17:35 ) Text 20 RN Type 1 Format 63

64 HV calibration (STEP 2) 1 Measurement step Measurement step 2 Number 1 2 SN Sample No. 1 Number 3 HV HV value 0 to 9999 Number 4 TIME Measurement time to Number 5 ESCR None None None 0 6 H-CPM Net CPM 0.00 to Number 7 H-EFF Count efficiency 0.00 to Number 8 C-CPM None None None 0 9 C-EFF None None None 0 10 CO-CPM Net CPM 0.00 to Number 11 CO-EFF Count efficiency 0.00 to Number 12 GL-CPM None None None 0 13 γ-cut None None None 0 14 β-cut None None None 0 15 Flag 1 None None None 0 16 Flag 2 None None None 0 17 Date/Time Date and time that measurement was completed (expressed in standard non-japanese date format and 24-hour time format) YYYY/MM/DD hh:mm ( 2014/01/31 17:35 ) Text Type 1 Format RN

IM3523 IM3533 IM IM3536 LCR METER IM3570 IM7580 IM3590 CHEMICAL IMPEDANCE ANALYZER IMPEDANCE ANALYZER. Communication Instruction Manual

IM3523 IM3533 IM IM3536 LCR METER IM3570 IM7580 IM3590 CHEMICAL IMPEDANCE ANALYZER IMPEDANCE ANALYZER. Communication Instruction Manual Communication Instruction Manual IM3523 IM3533 IM3533-01 IM3536 LCR METER IM3570 IM7580 IMPEDANCE ANALYZER IM3590 CHEMICAL IMPEDANCE ANALYZER November 2014 Revised edition 6 IM3570A983-06 14-11H i Contents

More information

Connection Guide (RS-232C)

Connection Guide (RS-232C) Programmable Controller CJ-series General-purpose Serial Connection Guide (RS-232C) MARS TOHKEN SOLUTION CO.LTD. Fixed Mount 2D Image Reader (MVF-300/500 Series) P679-E1-01 About Intellectual Property

More information

Manual Version: V1.00. Video Decoder User Manual

Manual Version: V1.00. Video Decoder User Manual Manual Version: V1.00 Video Decoder User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

Wireless Data Acquisition System Hardware System Setting Software MODEL: WDS-WIN01 Instruction Manual [Web version]

Wireless Data Acquisition System Hardware System Setting Software MODEL: WDS-WIN01 Instruction Manual [Web version] B95100536_02 Wireless Data Acquisition System Hardware System Setting Software Instruction Manual Wireless Data Acquisition System Hardware System Setting Software MODEL: WDS-WIN01 Instruction Manual [Web

More information

Data setting software MEXE02

Data setting software MEXE02 HM-40143 Data setting software MEXE02 OPERATING MANUAL Before Use Thank you for purchasing an Oriental Motor product. This operating manual describes product handling procedures and safety precautions.

More information

Manual Version: V1.00. Video Decoder Quick Guide

Manual Version: V1.00. Video Decoder Quick Guide Manual Version: V1.00 Video Decoder Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

Wireless Data Acquisition System Hardware System Setting Software MODEL: WDS-WIN01 Instruction Manual [Web version]

Wireless Data Acquisition System Hardware System Setting Software MODEL: WDS-WIN01 Instruction Manual [Web version] B95100536_03 Wireless Data Acquisition System Hardware System Setting Software Instruction Manual Wireless Data Acquisition System Hardware System Setting Software MODEL: WDS-WIN01 Instruction Manual [Web

More information

NUAGE Workgroup Manager. Operation Manual

NUAGE Workgroup Manager. Operation Manual NUAGE Workgroup Manager Operation Manual EN Contents Information...3 NUAGE Workgroup Manager An Introduction...3 Launching & Shutting Down...3 Launching... 3 Shutting down... 3 Using the Application...4

More information

PS-9000 User s Manual UK English

PS-9000 User s Manual UK English PS-9000 User s Manual UK English Introduction Thank you for purchasing PS-9000 print server. This manual provides complete information on how to set up and use PS-9000 safely. Please read this manual carefully

More information

Operating Instructions. Windows. Video Wall Adjustment & Calibration Software. Video Wall Manager Ver. 1.8

Operating Instructions. Windows. Video Wall Adjustment & Calibration Software. Video Wall Manager Ver. 1.8 Operating Instructions Video Wall Adjustment & Calibration Software Windows Video Wall Manager Ver. 1.8 Thank you for purchasing this Panasonic product. Before using this software, please read the instructions

More information

Schneider Electric AB DH485 Protocol XBT N/R/RT

Schneider Electric AB DH485 Protocol XBT N/R/RT Schneider Electric AB DH485 Protocol XBT N/R/RT 33004016 06/2008 33004016.01 2 33004016 06/2008 Table of Contents Safety Information....................................5 About the Book.......................................7

More information

DX200 OPTIONS INSTRUCTIONS

DX200 OPTIONS INSTRUCTIONS DX200 OPTIONS INSTRUCTIONS FOR CMOS SAVE FUNCTION WITH FTP ADVANCED FEATURE OF DX200 EHTERNET FUNCTION Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and

More information

DX200 OPTIONS INSTRUCTIONS

DX200 OPTIONS INSTRUCTIONS DX200 OPTIONS INSTRUCTIONS FOR ETHERNET FUNCTION Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference. MOTOMAN INSTRUCTIONS MOTOMAN--

More information

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice. MCD Modbus Module Instructions Important User Information INSTALLATION INSTRUCTIONS: MCD MODBUS MODULE Order Code: 175G9000 1. Important User Information Observe all necessary safety precautions when controlling

More information

Centralized Controller AG-150A GB-50ADA-A GB-50ADA-J

Centralized Controller AG-150A GB-50ADA-A GB-50ADA-J Air-conditioner Network System Centralized Controller AG-150A GB-50ADA-A GB-50ADA-J Instruction Book (Web browser for optional functions) Contents 1 Introduction...1 1-1 Terms Used in This Manual... 1

More information

Air-conditioner Control System Centralized Controller AG-150A AG-150A-A GB-50ADA-J

Air-conditioner Control System Centralized Controller AG-150A AG-150A-A GB-50ADA-J Air-conditioner Control System Centralized Controller AG-150A AG-150A-A GB-50ADA-A GB-50ADA-J Instruction Book (Web browser for optional functions) Contents 1 Introduction... 1 1-1 Terms Used in This Manual...

More information

Host Communication Tester Instruction Manual

Host Communication Tester Instruction Manual InfoSOSA Series Host Communication Tester Instruction Manual InfoSOSA Version 2.1 Seedsware Corporation http://www.seedsware.co.jp/global/ 12A4A5-00083E-3 Introduction This document describes the operation

More information

CJ Series General-purpose Serial Connection Guide OMRON Corporation V500-R2 Series Fixed Laser-Type Barcode Reader

CJ Series General-purpose Serial Connection Guide OMRON Corporation V500-R2 Series Fixed Laser-Type Barcode Reader CJ Series General-purpose Serial Connection Guide OMRON Corporation V500-R2 Series Fixed Laser-Type Barcode Reader P564-E1-01 About Intellectual Property Rights and Trademarks Microsoft product screen

More information

HPE FlexNetwork NJ5000 5G PoE+ Walljack Switch(JH237A)

HPE FlexNetwork NJ5000 5G PoE+ Walljack Switch(JH237A) HPE FlexNetwork NJ5000 5G PoE+ Walljack Switch(JH237A) Quick Start Guide 5998-7330R The information in this document is subject to change without notice. Copyright 2016 Hewlett Packard Enterprise Development

More information

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated

More information

Users Manual STP-103II. Thermal Printer Rev

Users Manual STP-103II. Thermal Printer Rev Users Manual STP-103II Thermal Printer Rev. 1.00 http://www.bixolon.com Safety Precautions The instructions shown below must be followed to prevent possible danger or damage by using the product incorrectly.

More information

MRZJW3- SETUP154E. General-Purpose AC Servo Servo Configuration Software MODEL INSTALLATION GUIDE

MRZJW3- SETUP154E. General-Purpose AC Servo Servo Configuration Software MODEL INSTALLATION GUIDE General-Purpose AC Servo Servo Configuration Software MODEL MRZJW3- SETUP154E INSTALLATION GUIDE Thank you for choosing the Mitsubishi general-purpose AC servo Servo Configuration Software. To optimize

More information

NUAGE Workgroup Manager. Operation Manual

NUAGE Workgroup Manager. Operation Manual NUAGE Workgroup Manager Operation Manual EN Contents Information...3 NUAGE Workgroup Manager An Introduction...3 Launching & Shutting Down...3 Launching... 3 Shutting down... 3 Using the Application...4

More information

User Manual. Printer P-52RUE

User Manual. Printer P-52RUE User Manual P-52RUE Overview 3 4 2 5 1 6 13 12 7 11 10 9 8 Overview Table 1 Paper feed button 8 Ethernet RJ45 connection 2 Status indicator 9 USB device connection 3 Paper cutter 10 RS232 connection 4

More information

CP-EX252N/CP-EX302N/CP-EW302N

CP-EX252N/CP-EX302N/CP-EW302N LCD Projector CP-EX252N/CP-EX302N/CP-EW302N User's Manual (detailed) Network Guide Thank you for purchasing this product. This manual is intended to explain only the network function. For proper use of

More information

Model 375 Ethernet Software LMI Part No Software Manual Version October 2013

Model 375 Ethernet Software LMI Part No Software Manual Version October 2013 Model 375 Ethernet Software LMI Part No. 1370-055 Software Manual Version 1.5.2 Model 375 Ethernet Software LMI Part No. 1370-055 Software Manual Version 1.5.2 TABLE OF CONTENTS 1. General... 1 2. Installation...

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

FACTORY AUTOMATION. MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld

FACTORY AUTOMATION. MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld FACTORY AUTOMATION MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld R With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

Single-Axis Counter BDD 611

Single-Axis Counter BDD 611 Single-Axis Counter BDD 611 Technical Description, User's Guide english No. 611-150 D/E. Edition 0705; Subject to modification. Replaces edition 0701. www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765

More information

IndigoVision Enterprise NVR-AS 4000 Linux Appliance. Quick Start Guide

IndigoVision Enterprise NVR-AS 4000 Linux Appliance. Quick Start Guide IndigoVision Enterprise NVR-AS 4000 Linux Appliance Quick Start Guide THIS MANUAL WAS CREATED ON 18 FEBRUARY 2016. DOCUMENT ID: IU-NVR-MAN023-3 Legal Considerations LAWS THAT CAN VARY FROM COUNTRY TO COUNTRY

More information

C (1) Remote Controller. Setup software RM-IP Setup Tool guide Software Version Sony Corporation

C (1) Remote Controller. Setup software RM-IP Setup Tool guide Software Version Sony Corporation C-499-100-12 (1) Remote Controller Setup software RM-IP Setup Tool guide Software Version 1.1 2017 Sony Corporation Table of Contents Introduction... 3 Using This Manual...3 Downloading and Starting the

More information

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED D-500s Indicator D - 500 LED User Instructions English 8921-004210 Issue September 2010 1 2-2 0 1 0 D 6 0 0 4 6 7 5 Page 2 D-500s Indicator Page 2 Table of Content Section 1: Introduction. 1.1 Introduction

More information

PS-4700/4800Series User ユーザーマニュアル Hardware Manual Manual

PS-4700/4800Series User ユーザーマニュアル Hardware Manual Manual PS-4700/4800Series シリーズ User ユーザーマニュアル GP-4000 Pro-face Manual Series Remote HMI Server Hardware Manual Manual (Atom N270/Core 2 Duo 2 Duo P8400 P8400 Pre-installed 搭載モデル Model) ) Preface Thank you for

More information

MELSEC iq-f FX5 User's Manual (MELSEC Communication Protocol)

MELSEC iq-f FX5 User's Manual (MELSEC Communication Protocol) MELSEC iq-f FX5 User's Manual (MELSEC Communication Protocol) SAFETY PRECAUTIONS (Read these precautions before use.) Before using this product, please read this manual and the relevant manuals introduced

More information

MedDream MedDream SendToPACS USER S MANUAL (version 1.16)

MedDream MedDream SendToPACS USER S MANUAL (version 1.16) MedDream MedDream SendToPACS USER S MANUAL (version 1.16) 2016, Softneta UAB, Kaunas All rights reserved in the event of granting of patents or registration as a utility patent. All names of companies

More information

Cipher 1023 Magnetic Stripe Reader Installation and User's Guide. Document Number : Released Date : Dec 2, 1996

Cipher 1023 Magnetic Stripe Reader Installation and User's Guide. Document Number : Released Date : Dec 2, 1996 Cipher 1023 Magnetic Stripe Reader Installation and User's Guide Document Number : 1023-001-03 Released Date : Dec 2, 1996 WARNING Note: This equipment has been tested and found to comply with the limits

More information

CP-EX3051WN/CP-EX3551WN/CP-EX4551WN CP-EW3051WN/CP-EW3551WN/CP-EW4051WN

CP-EX3051WN/CP-EX3551WN/CP-EX4551WN CP-EW3051WN/CP-EW3551WN/CP-EW4051WN LCD Projector CP-EX3051WN/CP-EX3551WN/CP-EX4551WN CP-EW3051WN/CP-EW3551WN/CP-EW4051WN User's Manual (detailed) Network Guide Thank you for purchasing this product. This manual is intended to explain only

More information

fiber optic gateway control box

fiber optic gateway control box fiber optic gateway control box Product Overview Celerity Fiber Optic Gateway (FOG) products are designed for high performance, dependability and convenient installation in professional AV applications.

More information

RS232 User Guide. Planar Simplicity Series 4K Displays SL4364K SL5564K SL6564K SL7564K SL8664K. Simplicity Series 4K Displays User Guide A

RS232 User Guide. Planar Simplicity Series 4K Displays SL4364K SL5564K SL6564K SL7564K SL8664K. Simplicity Series 4K Displays User Guide A RS232 User Guide Planar Simplicity Series 4K Displays SL4364K SL5564K SL6564K SL7564K SL8664K 020-1344-00A Page 1 Copyright March 2018 by Leyard Optoelectronics Co., Ltd. and Planar Systems, Inc. All rights

More information

CyberComm Pro Data Acquisition Software Installation & User Guide

CyberComm Pro Data Acquisition Software Installation & User Guide CyberComm Pro 2.2.3 Data Acquisition Software Installation & User Guide ph 1100 and ph 2100 Bench ph and Bench ph/ion Meter Technology Made Easy... 68X090822 rev 1 Aug 2002 2 PREFACE Thank you for selecting

More information

IndigoVision Enterprise NVR-AS 4000 G3 Windows Appliance. Quick Start Guide

IndigoVision Enterprise NVR-AS 4000 G3 Windows Appliance. Quick Start Guide IndigoVision Enterprise NVR-AS 4000 G3 Windows Appliance Quick Start Guide THIS MANUAL WAS CREATED ON TUESDAY, NOVEMBER 27, 2018. DOCUMENT ID: IU-NVR-MAN031-2 Legal Considerations LAWS THAT CAN VARY FROM

More information

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional Setting up security in STEP 7 Professional SIMATIC NET Industrial Ethernet Security Setting up security in STEP 7 Professional Preface 1 User interface and menu commands 2 Basic configuration 3 Firewall

More information

MedDream SendToPACS. USER S MANUAL (version )

MedDream SendToPACS. USER S MANUAL (version ) MedDream SendToPACS USER S MANUAL (version 1.17.1809.0100) 2018, Softneta UAB, Kaunas All rights reserved in the event of granting of patents or registration as a utility patent. All names of companies

More information

CP-WU8700/CP-WX8750/CP-X8800 CP-WU8600/CP-WX8650

CP-WU8700/CP-WX8750/CP-X8800 CP-WU8600/CP-WX8650 Projector CP-WU8700/CP-WX8750/CP-X8800 CP-WU8600/CP-WX8650 User's Manual (detailed) Network Guide Thank you for purchasing this product. This manual is intended to explain only the network function. For

More information

General Operating, Maintenance and Installation Manual

General Operating, Maintenance and Installation Manual General Operating, Maintenance and Installation Manual Hardware Platform for Protocol Converter Small Embedded Controller - SEC2-91056 Erlangen Telephone +49 9131 92076-0 Fax: +49 9131 92076-10 Internet:

More information

FX-USB-AW/FX3U-USB-BD. USER'S MANUAL USB Driver Installation Edition

FX-USB-AW/FX3U-USB-BD. USER'S MANUAL USB Driver Installation Edition FX-USB-AW/FX3U-USB-BD USER'S MANUAL Safety Precautions (Read these precautions before use.) BEFORE installation, operation, maintenance or inspection of this product, thoroughly read through and understand

More information

PT-VW330U/PT-VX400U PT-VW330E/PT-VX400E PT-VW330EA/PT-VX400EA

PT-VW330U/PT-VX400U PT-VW330E/PT-VX400E PT-VW330EA/PT-VX400EA Operating Instructions Network Operations LCD Projector Commercial Use Model No. PT-VW330U/PT-VX400U PT-VW330E/PT-VX400E PT-VW330EA/PT-VX400EA This manual explains the network operation of the projector.

More information

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual RS-232/422/485 to Copper or Fiber Ethernet Converter User s Manual Table Of Contents TABLE OF CONTENTS... 1 INTRODUCTION... 3 PRODUCT OVERVIEW... 3 PRODUCT FEATURES... 3 PACKING LIST... 4 LED INDICATORS...

More information

Select a Data Communication Interface

Select a Data Communication Interface Printer Setup and Operation Select a Data Communication Interface Select a Data Communication Interface You may connect your print engine to a computer using one or more of the available connections. The

More information

PT-EX16KE PT-EX16KU. Operating Instructions. Network Operations. LCD Projector Commercial Use. Model No.

PT-EX16KE PT-EX16KU. Operating Instructions. Network Operations. LCD Projector Commercial Use. Model No. Operating Instructions Network Operations LCD Projector Commercial Use Model No. PT-EX6KE PT-EX6KU This manual explains the network operation of the projector. For information other than the network operation,

More information

CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide. CyberScan DO 1500

CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide. CyberScan DO 1500 CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide CyberScan DO 1500 Bench Dissolved Oxygen Meter Technology Made Easy... 68X292341 Rev.0 01/04 PREFACE Thank you for selecting the CyberScan

More information

Scanner Reference. Operating Instructions

Scanner Reference. Operating Instructions Operating Instructions Scanner Reference 1 2 3 4 5 6 7 Sending Scan Files by E-mail Sending Scan Files to Folders Storing Files Using the Scanner Function Delivering Scan Files Scanning Originals with

More information

RTS ISDN 2002 System. Operator Manual Software Description

RTS ISDN 2002 System. Operator Manual Software Description RTS ISDN 2002 System Operator Manual Software Description PAGE 1-2 RTS ISDN 2002 System A Publication of EVI Audio GmbH Hirschberger Ring 45 D-94315 Straubing Telephone + 49 9421 706-0 Fax + 49 9421 706-422

More information

WinCT-Plus Instruction Manual

WinCT-Plus Instruction Manual WinCT-Plus Instruction Manual (OP-08) Please see the separate document "Manual(for the AD8526)" if the AD8526(Ethernet Converter) is used. Ver.2.01 Mar. 21, 2008 Contents 1. Introduction ---------------------------------------------------------------------------------------------------

More information

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication. 3-3 Wiring NQ-Series models have, besides one power connector, a number of communication ports. Please refer to Table 2.2: Common specifications for NQ-Series and Table 2.3: Specifications per NQ-Series

More information

ROHS AND WEEE COMPLIANCE

ROHS AND WEEE COMPLIANCE 210Z ROHS AND WEEE COMPLIANCE All lead-free products offered by the company comply with the requirements of the European law on the Restriction of Hazardous Substances (RoHS) directive, which means our

More information

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1 Preface Connecting SCALANCE S615 to the WAN 1 SIMATIC NET VPN tunnel between SCALANCE S615 and 2 SINEMA RC Server Industrial Ethernet Security Getting Started 07/2017 C79000-G8976-C390-02 Legal information

More information

CJ Series General-purpose Serial Connection Guide (RS-232C) OMRON Corporation Displacement Sensor (ZW-7000 series)

CJ Series General-purpose Serial Connection Guide (RS-232C) OMRON Corporation Displacement Sensor (ZW-7000 series) CJ Series General-purpose Serial Connection Guide (RS-232C) OMRON Corporation Displacement Sensor (ZW-7000 series) P652-E1-01 About Intellectual Property Rights and Trademarks Microsoft product screen

More information

User Guide. Modbus Module. For Digistart soft starters. Part Number: Issue: 3.

User Guide. Modbus Module. For Digistart soft starters. Part Number: Issue: 3. User Guide Modbus Module For Digistart soft starters Part Number: 477-9-3 Issue: 3 General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent

More information

MODEL : CT-E351ET Ethernet Interface function Manual. Ver.1.01

MODEL : CT-E351ET Ethernet Interface function Manual. Ver.1.01 MODEL : CT-E351ET Ethernet Interface function Manual Ver.1.01 Contents Contents... 2 Read before using... 3 1. Introduction... 4 1-1. Specifications... 4 1-2. Part Names and Functions... 5 1-3. LED Functions...

More information

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

PT-TW230U/PT-TW231RU PT-TW230E/PT-TW231RE PT-TW230EA/PT-TW231REA

PT-TW230U/PT-TW231RU PT-TW230E/PT-TW231RE PT-TW230EA/PT-TW231REA Operating Instructions Network Operations LCD Projector Commercial Use Model No. PT-TW30U/PT-TW3RU PT-TW30E/PT-TW3RE PT-TW30EA/PT-TW3REA This manual explains the network operation of the projector. For

More information

Connection Guide HMS Industrial Networks

Connection Guide HMS Industrial Networks Machine Automation Controller NJ-series EtherCAT(R) Connection Guide HMS Industrial Networks Anybus Communicator P560-E1-02 About Intellectual Property Rights and Trademarks Microsoft product screen shots

More information

Copyright: December 2017 Nidec Issue: E

Copyright: December 2017 Nidec Issue: E General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional parameters of the equipment

More information

PowerLogic TM Series E4800 Multi-Circuit Meters. Configuration Guide

PowerLogic TM Series E4800 Multi-Circuit Meters. Configuration Guide PowerLogic TM Series E4800 Multi-Circuit Meters Configuration Guide PowerLogic TM E4800 Series 930-112-01 02/2009 Hazard Categories and Special Symbols Read these instructions carefully and look at the

More information

Installing and Managing the Switch

Installing and Managing the Switch CHAPTER 2 This chapter describes how to install and manage the Cisco SFS 7008 system hardware and contains these sections: Safety, page 2-2 Preparing the Site, page 2-3 Rack-Mounting the Switch, page 2-4

More information

DTSX3000 Communications(Modbus) Guide

DTSX3000 Communications(Modbus) Guide User s Manual DTSX3000 Communications(Modbus) Guide First Edition Blank Page < Introduction > i Introduction About this Manual Thank you for purchasing the DTSX3000 Distributed Temperature Sensor. This

More information

User Manual Revision English

User Manual Revision English Document code: MN67140_ENG Revision 1.011 Page 1 of 18 User Manual Revision 1.011 English DeviceNet Slave / Modbus TCP Slave - Converter (Order Code: HD67140-A1 HD67140-B2) for Website information: www.adfweb.com?product=hd67140

More information

FEC-240G. Rev. Date

FEC-240G. Rev. Date Model User s Manual Contents Contents. 1 Features... 2 Type Model and Serial Number... 2 Specifications... 3 Interface Connections...... 4 DIP Switch Setting... 6 Dimension... 7 Command Set Table... 8

More information

PowerLogic TM Series EM4800 Multi-Circuit Meters. Configuration Guide

PowerLogic TM Series EM4800 Multi-Circuit Meters. Configuration Guide PowerLogic TM Series EM4800 Multi-Circuit Meters Configuration Guide PowerLogic TM EM4800 Series 930-112-01-B.00 01/2011 Hazard Categories and Special Symbols Read these instructions carefully and look

More information

User s Guide [Network Administrator]

User s Guide [Network Administrator] User s Guide [Network Administrator] Table of contents 1 Introduction 1.1 Welcome... 1-2 1.1.1 User's guides... 1-2 1.1.2 User's Guide... 1-2 1.2 Conventions used in this manual... 1-3 1.2.1 Symbols used

More information

This manual describes the installation, setup and operation of this equipment in details.

This manual describes the installation, setup and operation of this equipment in details. About This Manual This manual describes the installation, setup and operation of this equipment in details. Please read it carefully to make sure you can operate the multiplexer correctly. Important Avoid

More information

Mac Printer Driver User's Manual

Mac Printer Driver User's Manual Mac Printer Driver User's Manual Overview Descriptions of the TM-T0 Software Installer features. Installation Descriptions of install and uninstall. Using the Printer Driver Descriptions of simple printing

More information

Data editing software EZED3

Data editing software EZED3 HL-17149 Data editing software EZED3 OPERATING MANUAL Thank you for purchasing an Oriental Motor product. This Operating Manual describes product handling procedures and safety precautions. Please read

More information

TMNet WinConfig Ver.3 User's Manual

TMNet WinConfig Ver.3 User's Manual TMNet WinConfig Ver.3 User's Manual Product Summary Features and operation environment of the TMNet WinConfig, as well as its installation and uninstallation procedures. Setting Network Parameters Explanation

More information

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015) SMM Series 3G and GSM Modems Quick Start Guide Document Number: 0013-001-000272 () Documentation Control Generation Date: October 20, 2015 Cybertec Pty Limited All rights Reserved. No part of this publication

More information

EXCELL PRECISION CO., LTD.

EXCELL PRECISION CO., LTD. Excell Precision Limited 24. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part

More information

This document hosted by: Extension Load Cell Cable (OP-02)

This document hosted by: Extension Load Cell Cable (OP-02) This document hosted by: www.oldwillknottscales.com 17.1. Extension Load Cell Cable (OP-02) This cable is used for installing the indicator away from the base unit. This extension load cell cable is 5

More information

User s Guide. Combo DVR. Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice

User s Guide. Combo DVR. Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice Combo DVR User s Guide User please operate according to the DVR model that you purchased

More information

Cautions for Your Safety

Cautions for Your Safety . 2 Cautions for Your Safety Please comply with 'Cautions for Your Safety', which will lead you to use the product safely and properly to prevent any dangerous situations. Cautions are divided into 'Warning'

More information

Multi-Function Smart Indicator User Manual

Multi-Function Smart Indicator User Manual Multi-Function Smart Indicator User Manual EC30006 Content 1 Notice... 2 2 Specification... 2 3 Main parameter... 3 4 How to fix... 3 5 Port... 4 6 On/Off... 4 7 Charging... 4 8 Display... 5 9 Screen keypad...

More information

User Manual Revision English

User Manual Revision English Document code: MN67609_ENG Revision 1.001 Pagina 1 di 22 User Manual Revision 1.001 English PROFINET / DeviceNet Slave - Converter (Order Code: HD67609-A1) for Website information: www.adfweb.com?product=hd67609

More information

Product Manual. 8-Port RS-232 USB to Serial Adapter Data Control Box. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM

Product Manual. 8-Port RS-232 USB to Serial Adapter Data Control Box. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM 8-Port RS-232 USB to Serial Adapter Data Control Box Product Manual Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM 2 USB-8COM Product Manual Revision History Revision Date Author Comments

More information

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6. Section Mounting Dimensions / Viewing 2 Mounting Options 3 Section 2 Wiring Configuration 4 Section 3 Quick Set up Procedure 5 Section 4 Changing Intensity 6 Section 5 Option Summary 7 Section 6 Option

More information

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode Global FW Rulesets SIMATIC NET Industrial Ethernet Security Preface 1 Firewall in standard mode 2 Firewall in advanced mode 3 Configuring a VPN tunnel 4 Configuring remote access via a VPN tunnel 5 Getting

More information

TASCAM SS-CDR250N/SS-R250N CONTROL I/O Terminals RS-232C/TELNET Protocol Specifications

TASCAM SS-CDR250N/SS-R250N CONTROL I/O Terminals RS-232C/TELNET Protocol Specifications TASCAM CONTROL I/O Terminals RS-232C/TELNET Protocol Specifications Ver. 1.11 July 2017 TEAC Corporation - 1 - CAUTION TEAC Corporation (hereafter, "TEAC") permits the use of the protocol described in

More information

Wavy for PLZ-4W Ver. 4.0

Wavy for PLZ-4W Ver. 4.0 Operation Manual Sequence Creation Software Wavy for PLZ-4W Ver. 4.0 Version 4.0 Prepared: June 21, 2006 KIKUSUI ELECTRONICS CORPORATION 1/35 Note Before contacting us to request repair, inspection, or

More information

Specification. For. Serial Interface DN-T645/625

Specification. For. Serial Interface DN-T645/625 Date 2002-08-30 1 page of 55 Specification For Serial Interface DN-T645/625 Denon, Ltd. Date 2002-08-30 2 page of 55 Histories Rev. Date Name Description 1.00 Aug., 30, 02 J.Watanabe Date 2002-08-30 3

More information

ELK-IP232 INSTALLATION AND CONFIGURATION MANUAL. Ethernet to Serial Bridge /07

ELK-IP232 INSTALLATION AND CONFIGURATION MANUAL. Ethernet to Serial Bridge /07 ELK-IP232 Ethernet to Serial Bridge INSTALLATION AND CONFIGURATION MANUAL http://www.ness.com.au email: support@ness.com.au 1/07 Table of Contents Features and Specifications...3 Basics of Networking...4

More information

RGM180 Display Series

RGM180 Display Series Quick Start Guide RGM180 Display Series BG0509 REV.A2 RGM180 QUICKSTART LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument for faulty workmanship or

More information

EQ-DCM User Manual Revision 1.02 Sep 10, 2013

EQ-DCM User Manual  Revision 1.02 Sep 10, 2013 EQ-DCM User Manual www.equustek.com Revision 1.02 Sep 10, 2013 Contents INTRODUCTION...5 ABOUT THIS MANUAL... 5 INTENDED AUDIENCE... 5 HARDWARE SPECIFICATIONS...6 PHYSICAL SPECIFICATIONS... 6 HARDWARE

More information

ABLELink. Modbus Gateway MB5000 Series User s Manual

ABLELink. Modbus Gateway MB5000 Series User s Manual ABLELink MB5000 Series User s Manual Version 1.1 Updated in March, 2010 TEL: 886-3-5508137 FAX: 886-3-5508131 http://www.atop.com.tw Table of Contents Table of Contents... 2 Introduction... 4 Features...

More information

DriveWizard Plus Instruction Manual

DriveWizard Plus Instruction Manual DriveWizard Plus Instruction Manual To properly use the product, read this manual thoroughly. MANUAL NO. TOEP C730600 20C Table of Contents Safety Symbols and Markings...4 Manual Overview...5 Related Manuals...5

More information

User Manual Revision English

User Manual Revision English Document code: MN67118_ENG Revision 2.002 Page 1 of 12 User Manual Revision 2.002 English RS232 / RS485 - Converter (Order Code: HD67118) Suitable for Heavy supervisor for Website information: www.adfweb.com?product=hd67118

More information

User Manual Revision English

User Manual Revision English Document code: MN67152_ENG Revision 1.002 Page 1 of 17 User Manual Revision 1.002 English HD67152-A1 DeviceNet Master / Modbus TCP Slave - Converter (Order Code: HD67152-A1 HD67152-B2) for Website information:

More information

Serial to Ethernet Converter

Serial to Ethernet Converter Serial to Ethernet Converter User s Manual Version 1.1 2004 Infosystem Technology Corporation Disclaimers The information in this manual has been carefully checked and is believed to be accurate. Infosystem

More information

USER MANUAL. VA-1USB-T USB Transmitter. VA-1USB-R USB Receiver MODELS: P/N: Rev 3

USER MANUAL. VA-1USB-T USB Transmitter. VA-1USB-R USB Receiver MODELS: P/N: Rev 3 KRAMER ELECTRONICS LTD. USER MANUAL MODELS: VA-1USB-T USB Transmitter VA-1USB-R USB Receiver P/N: 2900-300209 Rev 3 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2

More information

Printer Driver CASIO KL16H_EN

Printer Driver CASIO KL16H_EN Printer Driver CASIO KL16H_EN EN For Windows User s Guide Configuring Advanced Printer Driver Settings Deleting or Renaming a Printer A printer driver is printer control software that makes it possible

More information

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007 RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007 RS007 is a universal data converter which support serial RS232, RS422 and RS485 to the TCP / IP intelligent communication converter, it offers RS485/RS422

More information

EQ7000. User Manual. Rev 1.00

EQ7000. User Manual. Rev 1.00 EQ7000 User Manual Rev 1.00 www.equustek.com Revision 1.00 February 27, 2009 Contents INTRODUCTION...4 ABOUT THIS MANUAL...4 INTENDED AUDIENCE...4 HARDWARE SPECIFICATIONS...5 PHYSICAL SPECIFICATIONS...5

More information