How beam hardening influences the dimensional geometry in X-ray computed tomography

Size: px
Start display at page:

Download "How beam hardening influences the dimensional geometry in X-ray computed tomography"

Transcription

1 How beam hardening influences the dimensional geometry in X-ray computed tomography More info about this article: Hannah Corcoran 1, 2, Stephen Brown 2, Stuart Robson 1, Robert Speller 1, Michael McCarthy 1 1 University College London, Gower Street, London, WC1E 6BT, UK, h.corcoran.11@ucl.ac.uk, s.robson@ucl.ac.uk, r.speller@ucl.ac.uk, michael.mccarthy@ucl.ac.uk 2 National Physical Laboratory, Hampton Road, Teddington, TW11 0LW, UK, stephen.brown@npl.co.uk Abstract Dimensional and geometric measurements acquired using X-ray computed tomography can be affected by many variables. This paper focusses on the path length of the X-rays as they travel through an object, which in turn results in varying amounts of beam hardening. The effects of the orientation of the object during imaging is also studied. Four aluminum holeplates, with dimensions of ( ) mm are used, one being complex with a series of 4 mm holes and the others with just a single 4 mm hole in different positions. Results indicate that the amount of distortion to the apparent geometry (in the range of -75 µm to 115 µm) is correlated to the path length and therefore the amount of beam hardening that has occurred as the X-rays are attenuated by the objects. Keywords: Holeplate, dimensional metrology, beam hardening 1 Introduction X-ray computed tomography (XCT) is increasingly being used for dimensional and geometric measurements within manufacturing industries for inspection and quality control. However, there are multiple errors associated with the imaging, reconstruction and analysis processes. Due to the increasing use of this technology, these errors need to be characterized to ensure an increase in the accuracy and precision of the results obtained. This will lead, eventually, to the results being traceable to the SI unit, the metre, which will lead to increased confidence in the results. 1.1 Variables Dimensional and geometric results can be affected by many variables. The VDI/VDE (Association of German Engineers) list these variables in their document 26 Part 1.2 [1]. These variables can be associated with the system itself (e.g. stability of the source [2] and the accuracy of the positioning of the manipulator [3]), the system parameters used to image the object (e.g. voltage and current settings of the X-ray source) and the reconstruction method used. This paper discusses the orientation of the object during imaging and the path lengths of the X-rays as they travel through an object which in turn is related to the effect of beam hardening; this is discussed in Section Beam Hardening One of the errors associated with the acquisition of images using XCT is beam hardening. This is only found with polychromatic X-ray beams that consist of photons of multiple energies. As the X-ray beam travels through an object and is being attenuated, the lower energies are attenuated to a greater extent than the higher energies (see Figure 1). Number of photons 5x10 7 4x10 7 3x10 7 2x10 7 1x10 7 No filter 0.1 mm Copper 0.5 mm Copper Energy (kev) Figure 1: Energy spectrum of X-rays after travelling through varying thicknesses of copper (simulated in SpekCalc, an X-ray spectrum simulation program [4],[5],[6]). 1

2 This results in an increase in the mean energy of the propagating X-rays; this effect is known as beam hardening as the energies appear to become harder. An artefact is created within the images and is known as cupping. In a homogeneous object, where the greyscale values should be uniform, the edges will appear brighter and the centre will appear darker [7]. 1.2 Reference objects To develop a series of tests to simulate those objects and conditions found in industry is complicated therefore a simple object has to be used. A previous study by the authors [8] used a holeplate (see Figure 2), from which simple measurements of the form and geometry were taken. This previous work highlighted that the geometry of the holes within the holeplate varied systematically depending on the orientation of the holeplate when it was imaged. It also showed that the amount of material the X-rays had to pass through before and after reaching the holes affected results. Due to the large number of holes the path length of the X-rays was not a smooth function, it was therefore harder to understand the processes that were occurring. To investigate this further and to verify the cyclic responses, three simple holeplates were also manufactured at the National Physical Laboratory (NPL) (see Figure 3). The simple design allows a more fundamental understanding of how the shape of an object is affected when it is imaged using XCT. The more complex NPL holeplate along with these simple holeplates were used in this study. Although the object shapes are simple the measurements taken from these test objects could be used for more complex objects found in industry, such as cylinder bores found in engine blocks. 2 Method All experiments were carried out on a commercially available metrology XCT system with a maximum voltage of 225 kv and power of 225 W. The manufacturer states the Maximum Permissible Error as (9 + L/50) µm where L is in mm. 2.1 Holeplates The more complex holeplate was manufactured at NPL and is based on a design by Physikalisch-Technische Bundesanstalt (PTB) [9] and the ISO/TC 213/WG 10. It is ( ) mm in size and is made of aluminium, the holes have a nominal radius of 2 mm. Figure 2: NPL holeplate schematic showing position of holes. The simple holeplates have the same dimensions as the NPL holeplate but only have one hole. These correspond to the locations of holes found in the more complex holeplate to allow comparison of the results. A profile has been taken around the midpoint of the holes and the roundness is within ±5 µm. Both the NPL holeplate and the simple holeplate were imaged at 3 different orientations, 0, 45 and 90 to horizontal. The holeplates were supported on a carbon fibre frame and imaged at a magnification of times 1.6, giving a voxel size of 125 µm. Figure 3: holeplates with single holes. Hole number 6, 14 and 17 from left to right. 2

3 The simple holeplates were imaged at 170 kev and µm, this voltage was calculated to obtain a 14 % transmission through the holeplate when it was at 0. This level of transmission allows for the optimum contrast [10]. It was decided to keep the tube voltage at this setting for the other orientations for consistency. The XCT manufacturer s software was used to reconstruct the images into volumes. This voxel data was subsequently imported into VGStudio Max, version 2.2, a commercial visualisation and analysis software for XCT data, developed by Volume Graphics GmbH. To determine the surface of the holeplates, initially the greyscales for the air and the material were defined. This preliminary value was then used as a starting value for an algorithm that searches for the greatest rate of change in the greyscale across the air/material interface; this point is defined as the surface of the holeplate. Once a surface is determined a cylinder is fitted to the holes, this is done using a Chebyshev technique. Data about this cylinder can be obtained, including information on the fit points used to fit the cylinder. This information includes the x, y and z coordinates of the fit points and their deviations from the cylinder edge, as shown in Figure 4. Figure 4: Definitions used for a fitted cylinder. The coordinates of the fit points can be used to define the bearing of the fit point from the top of the holeplate, as shown in Figure 5. An average deviation was taken every 10 and these can then be used to define the shape of the holes. Figure 5: Orientation of bearing of fit point. When the holeplates are imaged at 0, the path lengths of the X-rays through the holeplate were calculated around the cylinders, from one edge of the holeplate to the other, through the centre of the hole, every 10. A schematic of this can be seen in Figure 6. Figure 6: Schematic of some path lengths through the holeplate, in this example for Cylinder 14. 3

4 3 Results The shape and geometry of the holes can be determined by studying the fit point deviations used to fit the cylinders. The fit points plotted against the average deviation taken every 10 can be seen below in Figure 7, Figure 8, Figure 9 and Figure Comparison of complex and simple holeplates at 0 orientation When imaging the complex NPL holeplate, Cylinder 17 as identified in Figure 2 as the central hole, shows the most distinctive trend with a trough at 45, 135, 225 and 315 bearing, the deviation being approximately - µm (see Figure 7). There are also peaks of equal magnitude at an offset of 45 to the troughs. The trends are very similar to when the simple holeplate was imaged with the peaks and troughs at similar bearings around the holes. For Cylinder 6 (identified in Figure 2), which is a corner hole, there are less defined peaks and troughs for the complex holeplates, the main trough being at 225 with a deviation of approximately - µm. The main peak is at 315 with a deviation of 10 µm. For the simple holeplate, the two peaks and troughs are much more pronounced, they also differ in amplitude. The deviations range from -75 µm to 115 µm. Cylinder 6 Cylinder Total path length (mm) Cylinder Path length (mm) Cylinder Cylinder Bearing (degrees) Cylinder Bearing (degrees) Figure 7: Fit point deviations around cylinder and total path length for the complex holeplate and the simple holeplates imaged at 0. It should be noted that the individual holes in the different holeplates are not identical. Path length (mm)

5 Both Cylinder 6 and 17 show a cyclic trend for both the complex and simple holeplates, this however is not the case for Cylinder 14. For the complex holeplate the deviations range from -25 µm to 18 µm. For the simple holeplate, the range is between -29 µm and 28 µm. When comparing the two trends for the two holeplates there does not appear to be a correlation. For Cylinder 6 there is a positive correlation between the deviations and the path lengths, i.e. as the path lengths increase the deviations become more positive. However, for Cylinders 14 and 17 the correlation is negative, as the path lengths increase the deviations become more negative. The path lengths for Cylinder 17 in the simple holeplate have a very symmetrical trend with troughs at the sides and peaks at the corners (as shown in Figure 7). However, this is not reflected in the deviation plots which are not even, this will be discussed further in section 4.1. Cylinder 6 Cylinder 14 Cylinder 17 0 degrees Deviation (mm) Figure 8: Comparison of all three holes at 0 orientation. When the holeplate is at 0 there is no correlation between fit point deviations and the bearing around the cylinders (as shown in Figure 8). Cylinder 6 has the biggest deviation range from -75 µm to 115 µm. Cylinder 14 shows the least variation with the fit points ranging from - 27 µm to 27 µm. 3.2 Comparison of orientations for simple holeplates during imaging Figure 7 illustrates how the apparent shape of the hole changes depending on the orientation of the holeplate. Each hole shows similar trends for orientations of 45 and 90, if in varying amounts. When the simple holeplates are imaged at 45, the maximum deviations can be found at a bearing of 0 /3 and 180. The central cylinder, cylinder 17, shows the greatest deviations, with a maximum of -70 µm at the top of the cylinder. Cylinder 14 shows the least deviation with a range of between -25 µm and 20 µm. When the simple holeplates are in a vertical position, 90, all holes show a cyclical trend, with troughs at a bearing of 45, 135, 215 and 315. The peaks for all three holes are less pronounced than the troughs and are not of similar amplitude. The peaks at 0 /3 and 180 are larger than those at 90 and 270 for all three holes. 45 degrees Cylinder 6 Cylinder 14 Cylinder degrees Deviation (mm) - Deviation (mm) Figure 9: Fit point deviations for the simple holeplates imaged at 0, 45 and 90 to the horizontal. 5

6 4 Discussion The results indicate that this series of tests is useful to characterize systematic errors during the imaging and measurement process when using XCT. All of the results indicate that the fit points vary around the cylinder and that they follow a trend depending on their bearing around the centre of the hole. When comparing the results from the previous study [8], it shows that the simple holeplates can exacerbate the problems associated with the cylindricity, especially if the hole is off centre of the holeplate, which is the case for Cylinders 6 and X-ray path lengths The graphs in Figure 7 show that there appears to be a correlation between the path length of the X-rays as they travel through the holeplate and the shape of the hole. However, as described in section 3.1 the correlation is not always positive and this makes it difficult to characterize as it can then not be presumed that the shape of an object should be corrected in a particular way just because the path length along that particular line is a given length. There appears to be an optimum length along which deformation does not occur. A study by Dewulf et al. [11] states that due to beam hardening, the number of photons hitting the detector, after attenuation by the material, is not strictly linearly related to the material thickness. The greyscale value of the pixel is related to the attenuation coefficient of the material which is dependent on the energy. As the effective energy is dependent on the path length (i.e. it increases as the X-ray beam becomes harder) the estimate of the pixel value is dependent on the path length. As mentioned earlier in Section 1.1.1, beam hardening changes the mean energy spectrum of the X-rays as it travels through an object. Figure 10 illustrates how the spectrum changes for the minimum and maximum path lengths found within the holeplates. This indicates how much the beam hardens as it travels through the holeplate and how this could change the apparent attenuation coefficients for a given part of the object resulting incorrect greyscale values being assigned to the pixels which results in apparent distortion in the geometry of the object. Number of photons 6x10 7 5x10 7 4x10 7 3x10 7 2x10 7 1x10 7 Simulated spectrum No material 13mm Aluminium 64mm Aluminium 3x10 5 2x10 5 1x Energy (kev) Figure 10: Simulated spectrum for minimum and maximum path lengths through simple holeplates (simulated in SpekCalc [4],[5],[6]). In Figure 7 the deviations of the fit points for Cylinder 17 are not exactly symmetrical indicating an uneven deformation despite the path lengths being even at different points around the holeplate; this would indicate that another error is affecting the results. This could include the source, holeplate and detector not being in exact alignment with each other. 4.2 Orientation of holeplate during imaging The simple holeplates more greatly illustrate the effects caused by the orientation of the holeplate during imaging. The results show that the shape of the hole is optimized and more accurate when the object is at 45 with all the holes having a systematic shape, the holes are however still being pushed in at the two poles. The errors are systematic when the holeplate is at 90 and show the same trends for all of the holes. The variation in deviation could again be caused partly by beam hardening, the amount of which will varying depending on the orientation as the path lengths will also change depending on the orientation. 4.3 Shape of cylinders and lines of symmetry When comparing the position of the hole within the overall holeplate and the surrounding material it can be seen that the deformation around a given hole is related to the symmetry of the holeplate itself, as seen in Figure 11. This is most obvious for Cylinder 6 where the shape of the hole is elliptical with the major axis running down the line of symmetry. It can be noted that 6

7 although the peaks run along this line the peak sizes are not even and this could be related to the fact that on the bearing of 315 there is a greater amount of material for the X-rays to travel through than at 135. Cylinder 17 in Figure 11 highlights the fact that the deviations are greatest when the path lengths are at their shortest. These errors are most likely associated with beam hardening. Villarreal et al. [12] state that the effective attenuation coefficient will change depending on the thickness of the material and this can lead to distortions in the reconstructed volume Cylinder Figure 11: Radial plots of the fit point deviations around the cylinders along with lines of symmetry (orange line). The fit points have been offset by 0.2 mm for ease of viewing Cylinder Cylinder Conclusions This series of experiments has shown that there is a correlation between the reconstructed geometry of a cylinder within a holeplate and the amount of material that X-rays have to pass through in order to create the images necessary for reconstruction. In the ( ) mm aluminum holeplate, clear systematic discrepancies of between -75 µm and 115 µm are apparent in the reconstruction for each 4 mm cylindrical hole, however, these errors are as yet not fully understood. For example, a longer X- ray path length through the plate does not necessarily mean a larger deformation so this needs to be investigated further. The use of a range of holeplates, each bearing just a single hole, but in different positions, provided a simple test object that is easily manufactured but shows efficiently the effects of differing X-ray path lengths through the material. Future work will include imaging the holeplates at a repeatable location to ensure alignment between the source, object and detector. The correct settings based on ISO [7] will also be used for the different orientations. The path lengths around the holes when the holeplates are at 45 and 90 will also be calculated. Acknowledgements This research is based on a collaborative project funded by the EPSRC (Engineering and Physical Sciences Research Council) and the National Physical Laboratory through the VEIV (Virtual Environments Interaction and Visualisation) Engineering Doctorate Centre at University College London. References [1] VDI/VDE-Richtlinien, VDI Computed tomography in dimensional measurements, Dusseldorf, [2] N. Flay, W. Sun, S. B. Brown, R. K. Leach, and T. Blumensath, Investigation of the Focal Spot Drift in Industrial Conebeam X-ray Computed Tomography, in Digital Industrial Radiology and Computed Tomography (DIR 2015) 22-25, 2015, no. June, pp [3] M. Ferrucci, R. K. Leach, C. L. Giusca, W. Dewulf, and S. Carmignato, Towards geometrical calibration of X-ray computed tomography systems - A review, Meas. Sci. Technol., vol. 26, p., [4] G. Poludniowski, G. Landry, F. DeBlois, P. M. Evans, and F. Verhaegen, SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes., Phys. Med. Biol., vol. 54, no. 19, pp. N433 N438, [5] G. Poludniowski and P. M. Evans, Calculation of x-ray spectra emerging from an x-ray tube. Part I: Electron penetration characteristics in x-ray targets, Med. Phys., vol. 34, no. 6, pp , [6] G. G. Poludniowskia, Calculation of x-ray spectra emerging from an x-ray tube. Part II. X-ray production and filtration in x-ray targets, Med. Phys., vol. 34, no. 6, pp , [7] J. F. Barrett and N. Keat, Artifacts in CT: recognition and avoidance., Radiographics, vol. 24, no. 6, pp , Jan [8] H. C. Corcoran, S. B. Brown, S. Robson, R. D. Speller, and M. B. McCarthy, Observations on the performance of X- Ray computed tomography for dimensional metrology, in International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences - ISPRS Archives, 2016, vol. 41, no. July, pp [9] M. Bartscher, O. Sato, F. Härtig, and U. Neuschaefer-Rube, Current state of standardization in the field of dimensional 7

8 computed tomography, Meas. Sci. Technol., vol. 25, no. 6, p , Jun [10] ISO, ISO pdf, Geneva, [11] W. Dewulf, Y. Tan, and K. Kiekens, Sense and non-sense of beam hardening correction in CT metrology, CIRP Ann. - Manuf. Technol., vol. 61, no. 1, pp , [12] C. B. Villarreal and B. G. Moreno, Beam hardening correction for signal to thickness calibration in digital radiography using the Medipix2 detector, Rev. Colomb. Fis., vol. 45, no. 1, pp ,

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL Developments in Dimensional Metrology in X-ray Computed Tomography at NPL Wenjuan Sun and Stephen Brown 10 th May 2016 1 Possible factors influencing XCT measurements Components Influencing variables Possible

More information

Coordinate Measuring Machines with Computed Tomography

Coordinate Measuring Machines with Computed Tomography Always a Step Ahead with Quality Coordinate Measuring Machines with Computed Tomography Multisensor Coordinate Measuring Machines with Computed Tomography Computed Tomography in Coordinate Measuring Machines

More information

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system ECNDT 2014 Prague October 6-10, 2014 Dr. Eberhard Neuser Dr. Alexander Suppes Imagination

More information

Analysis of Combined Probing Measurement Error and Length Measurement Error Test for Acceptance Testing in Dimensional Computed Tomography

Analysis of Combined Probing Measurement Error and Length Measurement Error Test for Acceptance Testing in Dimensional Computed Tomography Digital Industrial Radiology and Computed Tomography (DIR 2015) 22-25 June 2015, Belgium, Ghent - www.ndt.net/app.dir2015 More Info at Open Access Database www.ndt.net/?id=18038 Analysis of Combined Probing

More information

Creating a Multi-material Probing Error Test for the Acceptance Testing of Dimensional Computed Tomography Systems

Creating a Multi-material Probing Error Test for the Acceptance Testing of Dimensional Computed Tomography Systems Creating a Multi-material Probing Error Test for the Acceptance Testing of Dimensional Computed Tomography Systems More info about this article: http://www.ndt.net/?id=20848 Fabricio Borges de Oliveira

More information

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY David K. Lehmann 1, Kathleen Brockdorf 1 and Dirk Neuber 2 1 phoenix x-ray Systems + Services Inc. St. Petersburg, FL, USA 2 phoenix x-ray Systems + Services

More information

Multi-spectral (W, Mo, Cu, and Ag) XCT measurements

Multi-spectral (W, Mo, Cu, and Ag) XCT measurements Multi-spectral (W, Mo, Cu, and Ag) XCT measurements Marko Katić 1, Damir Markučič 1, Gorana Baršić 1 Faculty of mechanical engineering and naval architecture, Ivana Lucica 5, Zagreb, Croatia, marko.katic@fsb.hr

More information

Introduction to XCT and its growth

Introduction to XCT and its growth Introduction to XCT and its growth Professor Richard Leach FInstP FIoN Engineering Measurement Division Measurement Network Meeting, Loughborough April 2012 X-ray computed tomography History X-ray were

More information

Investigation of the kinematic system of a 450 kv CT scanner and its influence on dimensional CT metrology applications

Investigation of the kinematic system of a 450 kv CT scanner and its influence on dimensional CT metrology applications Investigation of the kinematic system of a 450 kv CT scanner and its influence on dimensional CT metrology applications Frank Welkenhuyzen 1, Bart Boeckmans 1, Ye Tan 1,2, Kim Kiekens 1,2, Wim Dewulf 1,2,

More information

An initial experimental study on the influence of beam hardening in X-ray CT for dimensional metrology

An initial experimental study on the influence of beam hardening in X-ray CT for dimensional metrology An initial experimental study on the influence of beam hardening in X-ray CT for dimensional metrology Joseph J. Lifton 1,2, Andrew A. Malcolm 2, John W. McBride 3 1 The University of Southampton, United

More information

Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography

Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography Natalia Grozmani 1, Andrea Buratti 1, Robert H. Schmitt 1 More info about this article:

More information

THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS

THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS A. Campos a*, A. Zorrilla a, F. Lasagni a a Materials & Processes dept., Center for Advanced Aerospace Technologies

More information

Parameter Dependent Thresholding for Dimensional X-ray Computed Tomography

Parameter Dependent Thresholding for Dimensional X-ray Computed Tomography International Symposium on Digital Industrial Radiology and Computed Tomography - Poster 12 Parameter Dependent Thresholding for Dimensional X-ray Computed Tomography Kim KIEKENS *, Ye TAN *, Jean-Pierre

More information

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape Tasuku Ito 1, Yutaka Ohtake 1, Yukie Nagai 2, Hiromasa Suzuki 1 More info about this article: http://www.ndt.net/?id=23662

More information

Industrial Computer Tomography for Dimensional Metrology: Overview of Influence Factors and Improvement Strategies

Industrial Computer Tomography for Dimensional Metrology: Overview of Influence Factors and Improvement Strategies 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Industrial Computer Tomography for Dimensional Metrology: Overview of Influence Factors and

More information

Case Studies in Nondestructive Testing and Evaluation

Case Studies in Nondestructive Testing and Evaluation Case Studies in Nondestructive Testing and Evaluation 6 (2016) 79 92 More info about this article: http://www.ndt.net/?id=20771 Contents lists available at ScienceDirect Case Studies in Nondestructive

More information

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography Characterization of microshells experimented on Laser Megajoule using X-Ray tomography More info about this article: http://www.ndt.net/?id=20881 Alexandre Choux, Lise Barnouin, Ludovic Reverdy, Marc Theobald

More information

Enhanced material contrast by dual-energy microct imaging

Enhanced material contrast by dual-energy microct imaging Enhanced material contrast by dual-energy microct imaging Method note Page 1 of 12 2 Method note: Dual-energy microct analysis 1. Introduction 1.1. The basis for dual energy imaging Micro-computed tomography

More information

Combining Analytical and Monte Carlo Modelling for Industrial Radiology

Combining Analytical and Monte Carlo Modelling for Industrial Radiology 19 th World Conference on Non-Destructive Testing 2016 Combining Analytical and Monte Carlo Modelling for Industrial Radiology Carsten BELLON, Gerd-Rüdiger JAENISCH, Andreas DERESCH BAM Bundesanstalt für

More information

CT Systems and their standards

CT Systems and their standards CT Systems and their standards Stephen Brown Engineering Measurement 11 th April 2012 Industrial X-ray computed tomography: The future of co-ordinate metrology? Burleigh Court, Loughborough University

More information

Quality control phantoms and protocol for a tomography system

Quality control phantoms and protocol for a tomography system Quality control phantoms and protocol for a tomography system Lucía Franco 1 1 CT AIMEN, C/Relva 27A O Porriño Pontevedra, Spain, lfranco@aimen.es Abstract Tomography systems for non-destructive testing

More information

Creating a Multi-Material Length Measurement Error Test for the Acceptance Testing of Dimensional Computed Tomography Systems

Creating a Multi-Material Length Measurement Error Test for the Acceptance Testing of Dimensional Computed Tomography Systems Creating a Multi-Material Length Measurement Error Test for the Acceptance Testing of Dimensional Computed Tomography Systems More info about this article: http://www.ndt.net/?id=20847 Fabrício Borges

More information

Frequency-based method to optimize the number of projections for industrial computed tomography

Frequency-based method to optimize the number of projections for industrial computed tomography More Info at Open Access Database www.ndt.net/?id=18739 Frequency-based method to optimize the number of projections for industrial computed tomography Andrea Buratti 1, Soufian Ben Achour 1, Christopher

More information

Experimental investigation of new multi-material gap reference standard for testing computed tomography systems

Experimental investigation of new multi-material gap reference standard for testing computed tomography systems More info about this article: http://www.ndt.net/?id=20837 Experimental investigation of new multi-material gap reference standard for testing computed tomography systems Petr Hermanek 1, Fabrício Borges

More information

Uncertainty Evaluation of Pore Analysis for Additively Manufactured Parts using Cross Sections

Uncertainty Evaluation of Pore Analysis for Additively Manufactured Parts using Cross Sections Uncertainty Evaluation of Pore Analysis for Additively Manufactured Parts using Cross Sections More info about this article: http://www.ndt.net/?id=23659 Abstract Leonard Schild 1, Manuel Fülling 1, Benjamin

More information

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube T. Donath* a, F. Pfeiffer a,b, O. Bunk a, W. Groot a, M. Bednarzik a, C. Grünzweig a, E. Hempel c, S. Popescu c, M. Hoheisel

More information

A cone-beam CT geometry correction method based on intentional misalignments to render the projection images correctable

A cone-beam CT geometry correction method based on intentional misalignments to render the projection images correctable A cone-beam CT geometry correction method based on intentional misalignments to render the projection images correctable Felix Meli, Benjamin A. Bircher, Sarah Blankenberger, Alain Küng, Rudolf Thalmann

More information

Wieblinger Weg 92a, Heidelberg, Germany, Phone: , Fax: ;

Wieblinger Weg 92a, Heidelberg, Germany, Phone: , Fax: ; HOW INDUSTRIAL COMPUTER TOMOGRAPHY ACCELERATES PRODUCT DEVELOPMENT IN THE LIGHT METAL CASTING AND INJECTION MOULDING INDUSTRY. Christof REINHART 1, Christoph POLIWODA 1, Thomas GÜNTHER 1 1 Volume Graphics

More information

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS 23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN 16-20 APRIL 2007 HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS P. Helberg 1,

More information

Scatter Correction Methods in Dimensional CT

Scatter Correction Methods in Dimensional CT Scatter Correction Methods in Dimensional CT Matthias Baer 1,2, Michael Hammer 3, Michael Knaup 1, Ingomar Schmidt 3, Ralf Christoph 3, Marc Kachelrieß 2 1 Institute of Medical Physics, Friedrich-Alexander-University

More information

Investigation on the influence of image quality in X-ray CT metrology

Investigation on the influence of image quality in X-ray CT metrology Investigation on the influence of image quality in X-ray CT metrology Pavel Müller 1, Jochen Hiller 1, Angela Cantatore 1, Markus Bartscher 2, Leonardo De Chiffre 1 1 Technical University of Denmark, Department

More information

Artifact Mitigation in High Energy CT via Monte Carlo Simulation

Artifact Mitigation in High Energy CT via Monte Carlo Simulation PIERS ONLINE, VOL. 7, NO. 8, 11 791 Artifact Mitigation in High Energy CT via Monte Carlo Simulation Xuemin Jin and Robert Y. Levine Spectral Sciences, Inc., USA Abstract The high energy (< 15 MeV) incident

More information

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling nd International Symposium on NDT in Aerospace - We..A. Comparison of Probing Error in Dimensional Measurement by Means of D Computed Tomography with Circular and Helical Sampling Jochen HILLER, Stefan

More information

CIVA Computed Tomography Modeling

CIVA Computed Tomography Modeling CIVA Computed Tomography Modeling R. FERNANDEZ, EXTENDE, France S. LEGOUPIL, M. COSTIN, D. TISSEUR, A. LEVEQUE, CEA-LIST, France page 1 Summary Context From CIVA RT to CIVA CT Reconstruction Methods Applications

More information

On the impact of probing form error on form measurement in Computed Tomography

On the impact of probing form error on form measurement in Computed Tomography On the impact of probing form error on form measurement in Computed Tomography Jan Lasson Andreasen 1, Filippo Montanari 2, Leonardo De Chiffre 2 More info about this article: http://www.ndt.net/?id=23729

More information

DUE to beam polychromacity in CT and the energy dependence

DUE to beam polychromacity in CT and the energy dependence 1 Empirical Water Precorrection for Cone-Beam Computed Tomography Katia Sourbelle, Marc Kachelrieß, Member, IEEE, and Willi A. Kalender Abstract We propose an algorithm to correct for the cupping artifact

More information

STUDY ON PARAMETER VARIATION OF AN INDUSTRIAL COMPUTED TOMOGRAPHY SIMULATION TOOL CONCERNING DIMENSIONAL MEASUREMENT DEVIATIONS

STUDY ON PARAMETER VARIATION OF AN INDUSTRIAL COMPUTED TOMOGRAPHY SIMULATION TOOL CONCERNING DIMENSIONAL MEASUREMENT DEVIATIONS STUDY ON PARAMETER VARIATION OF AN INDUSTRIAL COMPUTED TOMOGRAPHY SIMULATION TOOL CONCERNING DIMENSIONAL MEASUREMENT DEVIATIONS Michael REITER a, Christoph HEINZL a, Dietmar SALABERGER a, Daniel WEISS

More information

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications 4th International Symposium on NDT in Aerospace 2012 - Tu.3.A.1 Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications Malte KURFISS 1, Gerd STRECKENBACH 2 1 YXLON International

More information

More Info at Open Access Database

More Info at Open Access Database More Info at Open Access Database www.ndt.net/?id=18750 Abstract Enhancing the Accuracy of Computed Tomography Measurements using Data Filtering Alessandro Stolfi a, Maarja-Helena Kallasse b, Lorenzo Carli

More information

ENHANCED IMAGING OF CORROSION IN AIRCRAFT STRUCTURES WITH REVERSE GEOMETRY X-RAY

ENHANCED IMAGING OF CORROSION IN AIRCRAFT STRUCTURES WITH REVERSE GEOMETRY X-RAY ENHANCED IMAGING OF CORROSION IN AIRCRAFT STRUCTURES WITH REVERSE GEOMETRY X-RAY William P. Winfree a,noreen A. Cmar-Mascis b, F. Raymond Parker a a NASA Langley Research Center, MS 231, Hampton VA 23681-2199

More information

DUAL energy X-ray radiography [1] can be used to separate

DUAL energy X-ray radiography [1] can be used to separate IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 53, NO. 1, FEBRUARY 2006 133 A Scatter Correction Using Thickness Iteration in Dual-Energy Radiography S. K. Ahn, G. Cho, and H. Jeon Abstract In dual-energy

More information

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography Marc Kachelrieß, a Katia Sourbelle, and Willi A. Kalender Institute of Medical Physics, University of

More information

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE Rajesh et al. : Proceedings of the National Seminar & Exhibition on Non-Destructive Evaluation DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE Rajesh V Acharya, Umesh Kumar, Gursharan

More information

Case Studies in the Use of Computed Tomography for Non-Destructive Testing, Inspection and Measurement

Case Studies in the Use of Computed Tomography for Non-Destructive Testing, Inspection and Measurement SINCE2013 Singapore International NDT Conference & Exhibition 2013, 19-20 July 2013 Case Studies in the Use of Computed Tomography for Non-Destructive Testing, Inspection and Measurement Andrew A. MALCOLM,

More information

Digital Volume Correlation for Materials Characterization

Digital Volume Correlation for Materials Characterization 19 th World Conference on Non-Destructive Testing 2016 Digital Volume Correlation for Materials Characterization Enrico QUINTANA, Phillip REU, Edward JIMENEZ, Kyle THOMPSON, Sharlotte KRAMER Sandia National

More information

Optimization of scanner parameters for dual energy micro-ct

Optimization of scanner parameters for dual energy micro-ct Optimization of scanner parameters for dual energy micro-ct E. PAUWELS* 1, J. DHAENE 1, A. DE MUYNCK 1 E., M. DIERICK 1, L. VAN HOOREBEKE 1 1 UGCT Dept. Physics and Astronomy, Ghent University, Proeftuinstraat

More information

Use of reference objects for correction of measuring errors in X-ray computed tomography

Use of reference objects for correction of measuring errors in X-ray computed tomography Downloaded from orbit.dtu.dk on: Nov 19, 2018 Use of reference objects for correction of measuring errors in X-ray computed tomography Müller, Pavel Publication date: 2010 Document Version Publisher's

More information

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct J. DHAENE* 1, E. PAUWELS 1, T. DE SCHRYVER 1, A. DE MUYNCK 1, M. DIERICK 1, L. VAN HOOREBEKE 1 1 UGCT Dept. Physics

More information

Reducing the influence of environmental scattering in industrial computed tomography by system optimisation and correction algorithms

Reducing the influence of environmental scattering in industrial computed tomography by system optimisation and correction algorithms 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16395 Reducing the influence of environmental

More information

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste. 16648 Stephen Halliwell, VJ Technologies Inc, 89 Carlough Road, Bohemia, NY 11716, USA.

More information

Advanced Non-Destructive Testing by High Resolution Computed Tomography for 3D analysis of Automotive Components

Advanced Non-Destructive Testing by High Resolution Computed Tomography for 3D analysis of Automotive Components Advanced Non-Destructive Testing by High Resolution Computed Tomography for 3D analysis of Automotive Components J. Luebbehuesen GE Sensing & Inspection Technologies GmbH, phoenix x-ray, Niels-Bohr-Str.

More information

Non-Stationary CT Image Noise Spectrum Analysis

Non-Stationary CT Image Noise Spectrum Analysis Non-Stationary CT Image Noise Spectrum Analysis Michael Balda, Björn J. Heismann,, Joachim Hornegger Pattern Recognition Lab, Friedrich-Alexander-Universität Erlangen Siemens Healthcare, Erlangen michael.balda@informatik.uni-erlangen.de

More information

3D Computed Tomography (CT) Its Application to Aerospace Industry

3D Computed Tomography (CT) Its Application to Aerospace Industry 3D Computed Tomography (CT) Its Application to Aerospace Industry C. Muralidhar, M. P. Subramanian, V. Ravi Shankar and G. Chandrasekhar Directorate of Non Destructive Evaluation, Defence Research & Development

More information

Distance measurements on inaccessible wires in plastic parts with X-ray computed tomography

Distance measurements on inaccessible wires in plastic parts with X-ray computed tomography Distance measurements on inaccessible wires in plastic parts with X-ray computed tomography More info about this article: http://www.ndt.net/?id=20814 Michael Reiter 1, Christian Gusenbauer 1, Johann Kastner

More information

ASSESSMENT OF MEASUREMENT UNCERTAINTY CAUSED IN THE PREPARATION OF MEASUREMENTS USING COMPUTED TOMOGRAPHY

ASSESSMENT OF MEASUREMENT UNCERTAINTY CAUSED IN THE PREPARATION OF MEASUREMENTS USING COMPUTED TOMOGRAPHY XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal ASSESSMENT OF MEASUREMENT UNCERTAINTY CAUSED IN THE PREPARATION OF MEASUREMENTS USING COMPUTED TOMOGRAPHY

More information

Registration concepts for the just-in-time artefact correction by means of virtual computed tomography

Registration concepts for the just-in-time artefact correction by means of virtual computed tomography DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography, June 25-27, 2007, Lyon, France Registration concepts for the just-in-time artefact correction by means of virtual

More information

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa TOWARDS ESTABLISHMENT OF STANDARDIZED PRACTICE FOR ASSESSMENT OF SPATIAL RESOLUTION AND CONTRAST OF INTERNATIONAL

More information

SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory

SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory Introduction In this lab exercise, you will investigate the linearity of the DeskCAT scanner by making measurements

More information

ADS40 Calibration & Verification Process. Udo Tempelmann*, Ludger Hinsken**, Utz Recke*

ADS40 Calibration & Verification Process. Udo Tempelmann*, Ludger Hinsken**, Utz Recke* ADS40 Calibration & Verification Process Udo Tempelmann*, Ludger Hinsken**, Utz Recke* *Leica Geosystems GIS & Mapping GmbH, Switzerland **Ludger Hinsken, Author of ORIMA, Konstanz, Germany Keywords: ADS40,

More information

INFLUENCE OF GEOMETRICAL MAGNIFICATION ON COMPUTED TOMOGRAPHY DIMENSIONAL MEASUREMENTS

INFLUENCE OF GEOMETRICAL MAGNIFICATION ON COMPUTED TOMOGRAPHY DIMENSIONAL MEASUREMENTS DOI: 10.2507/27th.daaam.proceedings.090 INFLUENCE OF GEOMETRICAL MAGNIFICATION ON COMPUTED TOMOGRAPHY DIMENSIONAL MEASUREMENTS Amalija Horvatić Novak, Biserka Runje, Danijel Butković This Publication has

More information

COMPARISON OF ERROR MAPPING TECHNIQUES FOR COORDINATE MEASURING MACHINES USING THE PLATE METHOD AND LASER TRACER TECHNIQUE

COMPARISON OF ERROR MAPPING TECHNIQUES FOR COORDINATE MEASURING MACHINES USING THE PLATE METHOD AND LASER TRACER TECHNIQUE I IMEKO World Congress Fundamental and Applied Metrology September 6, 9, Lisbon, Portugal COMPARISON OF ERROR MAPPING TECHNIQUES FOR COORDINATE MEASURING MACHINES USING THE PLATE METHOD AND LASER TRACER

More information

Ch. 4 Physical Principles of CT

Ch. 4 Physical Principles of CT Ch. 4 Physical Principles of CT CLRS 408: Intro to CT Department of Radiation Sciences Review: Why CT? Solution for radiography/tomography limitations Superimposition of structures Distinguishing between

More information

Deep Scatter Estimation (DSE): Accurate Real-Time Scatter Estimation for X-Ray CT using a Deep Convolutional Neural Network

Deep Scatter Estimation (DSE): Accurate Real-Time Scatter Estimation for X-Ray CT using a Deep Convolutional Neural Network Deep Scatter Estimation (DSE): Accurate Real-Time Scatter Estimation for X-Ray CT using a Deep Convolutional Neural Network Joscha Maier 1,2, Stefan Sawall 1,2, and Marc Kachelrieß 1,2 1 German Cancer

More information

Radiographic Simulator artist: Version 2

Radiographic Simulator artist: Version 2 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Radiographic Simulator artist: Version 2 Carsten Bellon 1, Andreas Deresch 1, Christian Gollwitzer 1, Gerd-Rüdiger

More information

Comparison of Scatter Correction Methods for CBCT. Author(s): Suri, Roland E.; Virshup, Gary; Kaissl, Wolfgang; Zurkirchen, Luis

Comparison of Scatter Correction Methods for CBCT. Author(s): Suri, Roland E.; Virshup, Gary; Kaissl, Wolfgang; Zurkirchen, Luis Research Collection Working Paper Comparison of Scatter Correction Methods for CBCT Author(s): Suri, Roland E.; Virshup, Gary; Kaissl, Wolfgang; Zurkirchen, Luis Publication Date: 2010 Permanent Link:

More information

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM M. Simon, C. Sauerwein, I. Tiseanu, S. Burdairon Hans Wälischmiller GmbH Klingleweg 8, D-88709 Meersburg, Germany e-mail: ms@hwm.com ABSTRACT A new flexible

More information

Process Monitoring using three dimensional Computed Tomography and Automatic Image Processing

Process Monitoring using three dimensional Computed Tomography and Automatic Image Processing DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography, June 25-27, 2007, Lyon, France Process Monitoring using three dimensional Computed Tomography and Automatic Image

More information

Comparison of Reconstruction Methods for Computed Tomography with Industrial Robots using Automatic Object Position Recognition

Comparison of Reconstruction Methods for Computed Tomography with Industrial Robots using Automatic Object Position Recognition 19 th World Conference on Non-Destructive Testing 2016 Comparison of Reconstruction Methods for Computed Tomography with Industrial Robots using Automatic Object Position Recognition Philipp KLEIN 1, Frank

More information

Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field. Kouichi Inagaki ICC / IHI Corporation

Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field. Kouichi Inagaki ICC / IHI Corporation Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field Kouichi Inagaki ICC / IHI Corporation 13 th WORLD CONFERENCE ON INVESTMENT CASTING Paper: T3 Copyright

More information

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques SINCE2013 Singapore International NDT Conference & Exhibition 2013, 19-20 July 2013 Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image

More information

Voxel dataset noise reduction algorithm based on CMM reference measurements for geometrical tolerance analysis of prismatic test pieces

Voxel dataset noise reduction algorithm based on CMM reference measurements for geometrical tolerance analysis of prismatic test pieces Voxel dataset noise reduction algorithm based on CMM reference measurements for geometrical tolerance analysis of prismatic test pieces More info about this article: http://www.ndt.net/?id=21929 Crhistian

More information

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT Qiao Yang 1,4, Meng Wu 2, Andreas Maier 1,3,4, Joachim Hornegger 1,3,4, Rebecca Fahrig

More information

Background 8/2/2011. Development of Breast Models for Use in Simulation of Breast Tomosynthesis and CT Breast Imaging. Stephen J.

Background 8/2/2011. Development of Breast Models for Use in Simulation of Breast Tomosynthesis and CT Breast Imaging. Stephen J. Development of Breast Models for Use in Simulation of Breast Tomosynthesis and CT Breast Imaging Stephen J. Glick* J. Michael O Connor**, Clay Didier**, Mini Das*, * University of Massachusetts Medical

More information

Optiv CT160 Accurate measurement for every detail. Computed Tomography System

Optiv CT160 Accurate measurement for every detail. Computed Tomography System Optiv CT160 Accurate measurement for every detail Computed Tomography System Computed Tomography CT Technology. New prospects for metrology. Computed tomography (CT), a technology with unique advantages,

More information

TEP Hounsfield units. Related topics Attenuation coefficient, Hounsfield units

TEP Hounsfield units. Related topics Attenuation coefficient, Hounsfield units Hounsfield units TEP Related topics Attenuation coefficient, Hounsfield units Principle Depending on the type of CT scanner and the settings, the result of a CT scan of the same material can be different

More information

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT More Info at Open Access Database www.ndt.net/?id=18754 Novel evaluation method of low contrast resolution performance of dimensional X-ray CT Makoto Abe 1, Hiroyuki Fujimoto 1, Osamu Sato 1, Kazuya Matsuzaki

More information

Determination of Three-Dimensional Voxel Sensitivity for Two- and Three-Headed Coincidence Imaging

Determination of Three-Dimensional Voxel Sensitivity for Two- and Three-Headed Coincidence Imaging IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 50, NO. 3, JUNE 2003 405 Determination of Three-Dimensional Voxel Sensitivity for Two- and Three-Headed Coincidence Imaging Edward J. Soares, Kevin W. Germino,

More information

Introduction to Biomedical Imaging

Introduction to Biomedical Imaging Alejandro Frangi, PhD Computational Imaging Lab Department of Information & Communication Technology Pompeu Fabra University www.cilab.upf.edu X-ray Projection Imaging Computed Tomography Digital X-ray

More information

The PolyCT Increasing the sample throughput using multiple rotation axes

The PolyCT Increasing the sample throughput using multiple rotation axes The PolyCT Increasing the sample throughput using multiple rotation axes More info about this article: http://www.ndt.net/?id=21946 1 Dr. Nicolas Thiemeyer, Johannes Leisner 2, Michael Salamon 2, Carina

More information

Experimental accuracy assessment of different measuring sensors on workpieces with varying properties

Experimental accuracy assessment of different measuring sensors on workpieces with varying properties Experimental accuracy assessment of different measuring sensors on workpieces with varying properties Rauf Oezden 1,*, Metin Aclan 1 and Saliba Danho 2 1 Technical University of Cluj-Napoca, Ph.D. Stud.,

More information

Recognition and Measurement of Small Defects in ICT Testing

Recognition and Measurement of Small Defects in ICT Testing 19 th World Conference on Non-Destructive Testing 2016 Recognition and Measurement of Small Defects in ICT Testing Guo ZHIMIN, Ni PEIJUN, Zhang WEIGUO, Qi ZICHENG Inner Mongolia Metallic Materials Research

More information

CT vs. VolumeScope: image quality and dose comparison

CT vs. VolumeScope: image quality and dose comparison CT vs. VolumeScope: image quality and dose comparison V.N. Vasiliev *a, A.F. Gamaliy **b, M.Yu. Zaytsev b, K.V. Zaytseva ***b a Russian Sci. Center of Roentgenology & Radiology, 86, Profsoyuznaya, Moscow,

More information

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control Oliver BRUNKE 1,

More information

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon WHITE PAPER Introduction Introducing an image guidance system based on Cone Beam CT (CBCT) and a mask immobilization

More information

Industrial Computed Tomography Innovations

Industrial Computed Tomography Innovations GE Inspection Technologies Industrial Computed Tomography Innovations Premium performance for premium quality and speed. gemeasurement.com/ct Premium CT technologies. Faster than ever before. Every industrial

More information

USING cone-beam geometry with pinhole collimation,

USING cone-beam geometry with pinhole collimation, IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 56, NO. 3, JUNE 2009 687 A Backprojection-Based Parameter Estimation Technique for Skew-Slit Collimation Jacob A. Piatt, Student Member, IEEE, and Gengsheng L.

More information

INVESTIGATION OF MEASURING STRATEGIES IN COMPUTED TOMOGRAPHY

INVESTIGATION OF MEASURING STRATEGIES IN COMPUTED TOMOGRAPHY NEWTECH 2011 NEW TECHNOLOGIES IN MANUFACTURING ISBN 978-80-214-4267-2 INVESTIGATION OF MEASURING STRATEGIES IN COMPUTED TOMOGRAPHY Pavel Müller, Jochen Hiller, Angela Cantatore, Leonardo De Chiffre Technical

More information

A Large Scale Multiple Source X-ray CT System for Aerospace Applications

A Large Scale Multiple Source X-ray CT System for Aerospace Applications 5th International Symposium on NDT in Aerospace, 13-15th November 2013, Singapore A Large Scale Multiple Source X-ray CT System for Aerospace Applications Andrew A. MALCOLM, Tong LIU, Ivan Kee Beng NG,

More information

A geometry measurement system for a dimensional cone-beam CT

A geometry measurement system for a dimensional cone-beam CT A geometry measurement system for a dimensional cone-beam CT More info about this article: http://www.ndt.net/?id=21904 Benjamin A. Bircher, Felix Meli, Alain Küng, Rudolf Thalmann Federal Institute of

More information

CT Measurement Realization Process: The Need for Advanced Correction Methods

CT Measurement Realization Process: The Need for Advanced Correction Methods CT Measurement Realization Process: The Need for Advanced Correction Methods Crhistian R Baldo 1, Thiago L Fernandes 2, Gustavo D Donatelli 2, Gergely Szikszay-Molnar 3, Kostadin Doytchinov 3 1 Federal

More information

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control 6 th International Congress of Metrology, 06003 (203) DOI: 0.05/ metrology/20306003 C Owned by the authors, published by EDP Sciences, 203 A new Concept for High-Speed atline and inlinect for up to 00%

More information

Simulation-based correction of systematic errors for CT measurements

Simulation-based correction of systematic errors for CT measurements Simulation-based correction of systematic errors for CT measurements Andreas Michael Müller 1, Florian Wohlgemuth 1, Tino Hausotte 1 1 Institute of Manufacturing Metrology, Friedrich-Alexander-Universität

More information

X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection

X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection Mariusz Jedrychowski EN/MME-MM Introduction of new technique at CERN 12/12/2017

More information

Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran. DXRaySMCS First User Friendly Interface Developed for Prediction of Diagnostic Radiology X-Ray Spectra Produced by Monte Carlo (MCNP-4C) Simulation in Iran M.T. Bahreyni Toosi a*, H. Moradi b, H. Zare

More information

Methods for Quantitative Characterization of Large-Scale High Energy Computed Tomography Systems

Methods for Quantitative Characterization of Large-Scale High Energy Computed Tomography Systems More Info at Open Access Database www.ndt.net/?id=16704 Methods for Quantitative Characterization of Large-Scale High Energy Computed Tomography Systems Michael BÖHNEL 1, Andreas GRUBER 2, Nils REIMS 1,

More information

SPECT QA and QC. Bruce McBride St. Vincent s Hospital Sydney.

SPECT QA and QC. Bruce McBride St. Vincent s Hospital Sydney. SPECT QA and QC Bruce McBride St. Vincent s Hospital Sydney. SPECT QA and QC What is needed? Why? How often? Who says? QA and QC in Nuclear Medicine QA - collective term for all the efforts made to produce

More information

Process Monitoring using Three Dimensional Computed Tomography and Automatic Image Processing

Process Monitoring using Three Dimensional Computed Tomography and Automatic Image Processing ECNDT 2006 - We.3.7.1 Process Monitoring using Three Dimensional Computed Tomography and Automatic Image Processing Michael MAISL, Fraunhofer EZRT, Saarbrücken, Germany Stefan KASPERL, STEVEN OEKL, Fraunhofer

More information

An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography

An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography 4th International Symposium on NDT in Aerospace 2012 - Tu.3.A.3 An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography Jonathan HESS *, Patrick KUEHNLEIN *, Steven OECKL

More information

TOMOGRAPHIC RECONSTRUCTIONS AND PREDICTIONS OF RADIAL VOID DISTRIBUTION IN BWR FUEL BUNDLE WITH PART- LENGTH RODS

TOMOGRAPHIC RECONSTRUCTIONS AND PREDICTIONS OF RADIAL VOID DISTRIBUTION IN BWR FUEL BUNDLE WITH PART- LENGTH RODS TOMOGRAPHIC RECONSTRUCTIONS AND PREDICTIONS OF RADIAL VOID DISTRIBUTION IN BWR FUEL BUNDLE WITH PART- LENGTH RODS M. Ahnesjö *, P. Andersson Department of Physics and Astronomy Uppsala University, 75120,

More information

3D X-ray Laminography with CMOS Image Sensor Using a Projection Method for Reconstruction of Arbitrary Cross-sectional Images

3D X-ray Laminography with CMOS Image Sensor Using a Projection Method for Reconstruction of Arbitrary Cross-sectional Images Ke Engineering Materials Vols. 270-273 (2004) pp. 192-197 online at http://www.scientific.net (2004) Trans Tech Publications, Switzerland Online available since 2004/08/15 Citation & Copright (to be inserted

More information