1 Doc Rev B CROWN JEWEL TELEPHONE ENTRY SYSTEM INSTALLATION INSTRUCTIONS

2

3 TABLE OF CONTENTS IMPORTANT NOTICES... 3 INSTALLATION TIPS... 3 PART 1 PULLING CABLES... 4 A. WIRE INFORMATION... 4 B. SINGLE ENTRANCE CABLE REQUIREMENTS... 4 C. MULTIPLE ENTRANCE CABLE REQUIREMENTS... 5 PART 2 MOUNTING THE CABINET... 6 A. REMOVE THE FRONT PANEL ASSEMBLY... 6 B. MOUNT THE CABINET... 6 PART 3 WIRINGTHE UNIT... 7 A. MAIN PROCESSOR BOARD CONNECTIONS... 7 B. BYPASS BOARD CONNECTIONS... 8 PART 4 INSTALLING ADDITIONAL FEATURES A. AUX OPEN/REQUEST FOR ACCESS B. DOOR POSTION SENSING C. REMOTE KEYPAD D. AUTO-CALL SENSOR PART 5 TESTING AND ADJUSTING THE UNIT APPENDIX 1 INSTALLATION PROGRAMMING MENU APPENDIX 2 SYSTEM RESPONSES FCC REQUIREMENTS DOC REQUIREMENTS IMPORTANT: The Sentex Systems. warranty on this unit is conditioned upon Sentex Systems being paid in full for this equipment. This warranty will not be honored until such payment is received by Sentex Systems. Copyright 2000 All Rights Reserved This document is protected by copyright and may not be copied or adapted without the prior written consent of Sentex. This document contains information proprietary to Sentex and such information may not be distributed without prior written consent of Sentex. The software and firmware included in the Sentex Crown Jewel unit as they relate to this documentation are also protected by copyright and contain information proprietary to Sentex. Sentex Systems Chatsworth, CA Visit us at Rev B Doc Page 1 of 25

4 Belden and Datalene are registered trademarks of the Belden Corporation. Page 2 of 22 Doc Rev B

5 IMPORTANT NOTICES The Crown Jewel unit contains static sensitive parts. To avoid damage to the static sensitive parts, ground the unit and yourself while handling the board(s). Please follow the instructions in this manual closely. This document covers the specific actions needed to install the Crown Jewel system. An incorrect installation could end up causing you and your customer needless hours of aggravation. Prevent lightning damage to the unit. Install a Telephone Line Surge Suppresser as close to the Crown Jewel as possible. INSTALLATION TIPS Please read this section carefully before beginning your installation. The sections that follow contain detailed procedures for each step required to install a Crown Jewel system. In addition to those specific procedures, the following installation tips will help ensure your installation is done correctly and efficiently. 1. GROUND THE UNIT. The Crown Jewel contains parts which may be damaged by static discharge. A proper earth ground connected to the lower left grounding screw shown in Figure 3 will significantly reduce the chances of damage or improper operation. The shielding in the cables specified for all remote sensors and controls should also be connected to the earth ground at the Crown Jewel cabinet end of the cable only. To be effective, the ground connection must be made by running 12 awg copper wire to a good ground point (e.g., an electrical panel, a metallic cold water pipe that runs into the earth, or a grounding rod at least 10 feet in length that is driven into the earth) within 12 feet of the unit. Even if you have a good earth ground, you should try to discharge any static before handling the circuit boards. WARNING: Damage caused by static discharge is not covered by warranty. 2. PROVIDE POWER FROM A DEDICATED SOURCE. The outlet(s) into which you plug the Sentex provided transformer or a DC power supply should each be wired to their own circuit breaker. The optional CCTV must be plugged into a separate outlet. This will reduce line noise introduced into system power and minimize the risk of having other equipment interrupt unit operation. Each Crown Jewel unit and any door strikes must have their own individual transformer. 3. DO NOT OVERLOAD THE TERMINAL BLOCKS. The terminal blocks used in the Crown Jewel are removable and the pins are soldered into the boards. To connect your wires, remove the "head" from the correct terminals and open the screws. Insert the wire into the correct opening on the front and tighten the screw until the wire is held snugly. When you have made all connections for a given "head", plug it back onto the pins designated for that terminal block. Do the same for the optional CCTV board. Stranded wire must be between 16 and 24 awg. Solid wire must be between 18 and 24 awg. This is the total thickness measurement so, if you are putting two wires in, the combined thickness must fall within this range. NEVER try to insert more than two wires per terminal. 4. ENSURE GOOD CONNECTIONS. A light tug on the wire will tell you if the connection is secure. When reconnecting unit components, make sure all pins are straight on chips, connectors, and terminal block heads. 5. READ THE MARKINGS CAREFULLY. The connection points are marked on the boards clearly. Before making any connections, be sure to read the markings and check it against the corresponding figure in these instructions so that you understand the connection you are making. 6. TRAIN YOUR CUSTOMER. The Crown Jewel is easy to operate when you take a few minutes to train the user, but untrained users can cause serious problems for you and for themselves. SPEND THE TIME NOW to train your customer- it will save you both a lot of trouble later. Rev B Doc Page 3 of 25

6 A. WIRE INFORMATION PART 1 PULLING CABLES Unshielded cable is acceptable for indoor, weather-proof installations. Shielded cable is recommended for outdoor unit locations. Cable sizes are different for AC and DC power cables running the same distance (see Table 1). Separate cable is necessary for the optional CCTV (see Table 2). Table 1. Power Wire Distance for Crown Jewel DC POWER DISTANCE AC POWER WIRE SIZE WIRE SIZE 18 AWG 30' and under 18 AWG 18 AWG 30'-75' 16 AWG 18 AWG 75'-150' 12 AWG 16 AWG 150'-250' 10 AWG 12 AWG 250'-500' Table 2. Power Wire Distance for Optional CCTV DC POWER DISTANCE AC POWER WIRE SIZE WIRE SIZE 18 AWG 30' and under 18 AWG 18 AWG 30'-75' 18 AWG 18 AWG 75'-150' 14 AWG 16 AWG 150'-250' 12 AWG 12 AWG 250'-500' 10 AWG B. SINGLE ENTRANCE CABLE REQUIREMENTS Figure 1. Single Entrance Cable Runs and Grounds. The following cables must be run to the main processor board in the Crown Jewel cabinet: Main Processor Power: Run a 2-conductor cable from the outlet into which you will plug the Sentex supplied 12 VAC transformer (or the 12 VDC power supply you provide) to the Crown Jewel cabinet. See Table 1 above for the wire size required. Telephone Signal: Run 2-conductor 18 to 24 awg twisted pair telephone wires (Belden #8741 for unshielded and Belden #9502 for shielded installations or equivalent) from the bypass board location to: telephone line residence phone jack Crown Jewel cabinet (2 pairs). Ensure that the wire shields are grounded as shown in Figure 1, above. Accessory Control: Run 2 conductor cables from the door strike, magnetic lock, and/or gate operator to the Crown Jewel cabinet. See device specifications for wire size. Page 4 of 22 Doc Rev B

7 The following cables must be run to the CCTV board in the Crown Jewel cabinet: CCTV Power: Run a 2-conductor cable from the outlet into which you will plug the Sentex supplied 12 VAC transformer (or the 12 VDC power supply you provide) to the Crown Jewel cabinet. See Table 2 above for the wire size required. Video Monitor Signal: Run a coaxial cable with BNC connectors (Belden #9240 or equivalent) from the monitor or television to the Crown Jewel cabinet. Door Strike Power: Run 2 conductor cables from the power supplies to the door strikes. NOTE: If you are using Maglock, DC powered relays or DC powered door strikes, be sure to install a suppression diode or Metal Oxide Varistor across the coil (see Part 3 for details). Additional Features: Run wiring for additonal features as required (see Part 4): Aux Open/Request for Access Door Position Sensing Remote Keypad Auto-Call Sensor C. MULTIPLE ENTRANCE CABLE REQUIREMENTS Multiple entrance installations are identical to single entrance installations, except that an additional twisted pair 22 AWG telephone grade cable must be run between each bypass board location. Rev B Doc Page 5 of 25

8 PART 2 MOUNTING THE CABINET CAUTION The brass Crown Jewel cabinet is easily scratched. Use care when handling. Both the surface mount and flush-mount Crown Jewel cabinets are water-resistant, and may be located either indoors or outdoors. Mount the cabinet as follows: A. REMOVE THE FRONT PANEL ASSEMBLY Figure 2. Removing Crown Jewel Front Panel Assembly NOTES: The removal procedure for surface mount and flush mount Crown Jewel is identical. The optional CCTV is not shown in figure Using the Sentex-supplied hollow hex tool, unscrew four screws located on the front panel. 2. Carefully remove the front panel/main processor board assembly and place on a soft, clean surface. B. MOUNT THE CABINET Figure 3. Mounting the Crown Jewel Cabinet NOTE: The mounting procedure for surface mount and flush mount Crown Jewel is identical. 1. Carefully remove the knockout plug from the back or the bottom of the enclosure. 2. Mount the unit on the wall or pedestal securely. Mounting hardware is provided with Sentex's pedestal mount. Tighten all four screws/bolts. 3. Pull all wires into the cabinet. Page 6 of 22 Doc Rev B

9 PART 3 WIRING THE UNIT A. MAIN PROCESSOR BOARD CONNECTIONS Figure 4. Main Processor Board Connections. CAUTION Do not apply power to the unit until all other connections have been made. Damage to the unit may otherwise result. 1. GROUND THE CABINET in accordance with local code to a good earth/cold water ground nearby. The chassis ground lug is located on the lower left-hand corner of the Main Processor Board, as shown in Figure GATE/DOOR CONTROLS: Connect the wires from your gate operator or door strike and door strike power supply to TB1 as follows: a. Dry Contact Closures (most gate operators): Relay 1: connect conductors to "NO1" and "COM1" terminals. Relay 2: connect conductors to NO2 and COM2 terminals. b. Normally Locked Strikes: Relay 1: connect one conductor from your strike power supply to "NO1" and one conductor from the door strike to "COM1", then connect the remaining conductors from the power source and strike off of the board using a wire nut or butt splice. Relay 2: connect one conductor from your strike power supply to NO2 and one conductor from the door strike to COM2, then connect the remaining conductors from the source and strike off of the board using a wire nut or butt splice. c. Magnetic or Normally Open Strikes: Relay 1, connect one conductor from your power source to the "NC1" terminal and one conductor from the door strike to the "COM1" terminal. Then, connect the remaining conductors from the power source and the strike by tying them together using a wire nut or butt splice. For relay 2, connect one conductor from your power to the NC2 terminal and one conductor from the door strike to the COM2 terminal. Then, connect the remaining conductors from the source and the strike by tying them together using a wire nut or butt splice. Rev B Doc Page 7 of 25

10 WARNING! Magnetic locks and DC powered strikes generate voltage spikes that may damage the Crown Jewel unit. Sentex strongly recommends installing a IN4001 diode or a Metal Oxide Varistor across the magnetic lock coil. If the IN4001 diode is used, connect the cathode (the banded end) to the positive side of the coil and the anode to the negative side of the coil. 3. TELEPHONE LINE: connect two pairs of 18 to 24 AWG twisted pair telephone wires to TB3 on the main processor board, one wire to each pin. If you are using shielded wire for this connection, connect the shield for each of the cables to the chassis ground on the main processor board. CAUTION High voltages are present in the power supply area of the main processor board when power is connected to the Crown Jewel unit. Proceed with caution once power has been connected. 4. POWER: Connect the power cable to TB2 on the main processor board and to the transformer provided with the unit. The unit can also be powered by a 12 VDC power source, which also is connected to TB2. Polarity is unimportant for both AC and DC power. NOTE: The crown jewel will not charge a battery, so a UPS-type power supply must be used if a battery back-up is desired. B. OPTIONAL CCTV BOARD Figure 5. Optional CCTV Unit. 1. Connect a two conductor 10 to 18 AWG cable (Belden Datalene #9501 or equivalent) to TB 1 on the lower right corner of the CCTV Power Supply Board. See Table Connect coaxial cable with BNC connectors (Belden #9240 or equivalent) to J2, on the middle bottom of the CCTV Power Supply Board. Page 8 of 22 Doc Rev B

11 C. BYPASS BOARD CONNECTIONS The bypass board allows the Crown Jewel to be bypassed so normal telephone operation can be maintained in the event of a malfunction. 1. Standard Connection Figure 5. Bypass Board Hookup (Standard). Figure 6. Bypass Board Connections (Standard). 1. Connect TB3 on the main processor board to the SYSTEM area of the bypass board as shown in Figures 5 and Connect one set of the 18 to 24 AWG twisted pair telephone wires between the telephone line and the Bypass Board TELCO area as follows: a. On the Bypass Board TELCO area, connect the red wire to the tip terminal (marked as "T"), and the green wire to the ring terminal (marked as "R"). b. Connect the opposite ends of these wires to the incoming telephone line. 3. Connect the other set of twisted pair telephone wires between the home telephone block and the Bypass Board as follows: a. On the Bypass Board HOME area, connect the red wire to the tip terminal (marked as "T") and the green wire to the ring terminal (marked as "R"). b. Connect the opposite end of these wires to the telephone line entering the house. See Important Notes on following page. Rev B Doc Page 9 of 25

12 IMPORTANT NOTES Whenever the Crown Jewel unit is in use, the Bypass switch must be set to the OPERATE position. Should the Crown Jewel be disconnected for any reason, the Bypass switch must be set to BYPASS in order to maintain telephone service to the residence. In multiple unit installations, if you set the unit switches to BYPASS, you must also reset the unit ID numbers or the unit will malfunction (see Part 5 for information on setting unit ID numbers). 2. Alarm Unit Connections Figure 7. Bypass Board Hookup (with Alarm). Figure 8. Bypass Board Connections (with Alarm). IMPORTANT NOTE If the Crown Jewel will be used in conjunction with an alarm unit, it is imperative that the telephone line connect with the alarm unit first. If the units are not connected in this order, it will cause sporadic problems with both the alarm and the Crown Jewel unit (see Figure 6). 1. Connect TB3 on the main processor board to the SYSTEM area of the bypass board as shown in Figures 7 and Connect one set of the 18 to 24 AWG twisted pair telephone wires between the incoming telephone line and the Alarm unit. Page 10 of 22 Doc Rev B

13 3. Connect one set of the 18 to 24 AWG twisted pair telephone wires between the Alarm unit and the Bypass Board TELCO area as follows: A. On the Bypass Board TELCO area, connect the red wire to the tip terminal (marked "T"), and the green wire to the ring terminal (marked as "R"). B. Connect the opposite ends of these wires to the Alarm unit. 4. Connect the other set of twisted pair telephone wires between the home telephone block and the Bypass Board as follows: A. On the Bypass Board HOME area, connect the red wire to the tip terminal (marked "T") and the green wire to the ring terminal (marked as "R"). B. Connect the opposite end of these wires to the telephone line entering the house. IMPORTANT NOTES Whenever the Crown Jewel unit is in use, the Bypass switch must be set to the OPERATE position. Should the Crown Jewel be disconnected for any reason, the Bypass switch must be set to BYPASS in order to maintain telephone service to the residence. In multiple unit installations, if you set the unit switches to BYPASS, you must also reset the unit ID numbers or the unit will malfunction (see Part 5 for information on setting unit ID numbers). 3. Multiple Unit Connections NOTE: Figure. Bypass Board Connections (Multiple Units). Although reversed polarity will not damage or degrade Crown Jewel operation, some telephones will not dial if polarity is reversed. 1. Connect the multiple unit installation twisted pair cable between the TELCO area of the first unit and the HOME area of the second unit. 2. Repeat he same connection between all addtional units of the installation. 3. Connect the last unit between the TELCO area on the bypass board and the incoming telephone line. If multiple Crown Jewel s (up to 7 can be used in one installation) are to be installed at the same site, the bypass boards must be installed in series. See Important Notes on next page. Rev B Doc Page 11 of 25

14 IMPORTANT NOTES Whenever the Crown Jewel unit is in use, the Bypass switch must be set to the OPERATE position. Should the Crown Jewel be disconnected for any reason, the Bypass switch must be set to BYPASS in order to maintain telephone service to the residence. In multiple unit installations, if you set the unit switches to BYPASS, you must also reset the unit ID numbers or the unit will malfunction (see Part 5 for information on setting unit ID numbers). Page 12 of 22 Doc Rev B

15 PART 4 INSTALLING ADDITIONAL FEATURES The following features are connected the same for one or for multiple entrances. A. AUX OPEN/REQUEST FOR ACCESS Figure 10. TB5 and Earth Ground on the Main Processor Board. Any device that provides a contact closure (a Knox box or exit button) can be used to activate the entrance relays as follows: 1. To activate Relay 1, connect the device to terminals EXIT1 and COM of TB5 on the main processor board (see Figure 10). 2. To activate Relay 2 (if set as a control), connect the device to terminals EXIT2 and COM of TB5 on the main processor board (see Figure 10). Shielded cable should be used (such as Belden 8771). The connect the cable shield to the ground screw on the lower left corner of the main processor board (see Figure 10). B. DOOR POSTION SENSING The Crown Jewel can monitor the position of one entrance (if relay 2 is not set as control) and react to a change in its status. For example, if an entrance is either pried open, or is held open more than a minute after its relay deactivates, the unit can: Call the residence or other telephone number and report the status of the entrance, And/or close Relay 2 to activate a device such as a light, CCTV camera or siren. To activate this feature: 1. Install a normally closed switch either in the door frame or on the gate so that the switch is depressed when the door or gate is closed. 2. Connect one end of the wires to the door switch terminals labeled normally closed (NC) and common (COM). 3. Connect the other end of these wires to the EXIT2 and COM terminals of TB5 on the main processor board (see Figure 10) Use shielded cable such as Belden Connect the cable shield to the ground screw on the lower left corner of the main processor board (see Figure 10). For this feature to work, Relay 2 cannot be set as control. To activate this feature, Relay 2 must be set as a shunt, alarm, or CCTV. EXIT1 and COM are still available to activate Relay 1. If the door contact closure is broken, the Crown Jewel will call, report, and activate Relay 2. Rev B Doc Page 13 of 25

16 C. REMOTE KEYPAD Figure 11. Remote Keypad Wiring. The Crown Jewel accepts a second, remote keypad for added versatility. Install the remote keypad as follows: The remote keypad installation requires a shielded 7 conductor, 18 to 24 AWG cable such as Belden Datalene #9932 or equivalent. 1. Connect one end of the cable to TB4 on the Crown Jewel s main processor board (see Figure 11). 2. Connect the opposite end of the cable to area TB1 on the Remote Keypad board. 3. Connect the cable shield to the ground screw on the lower left corner of the main processor board (see Figure 11). D. AUTO-CALL SENSOR Figure 12. Auto-Call Wiring. The Crown Jewel has a special feature called Auto-Call which automatically places a visitor call to the residence when a driveway sensor (or any device that provides a contact closure) is activated. Connect a driveway sensor or other device to the Crown Jewel as follows: The Auto-Call installation requires a 2 conductor shielded cable (such as Belden 8771). 1. Connect one end of the cable to the driveway sensor. 2. Connect the other end of the cable to the AUTOCALL and COM pins on TB5 of the main processor board (see Figure 12). 3. Connect the cable shield to the ground screw on the lower left corner of the main processor board (see Figure 12). Page 14 of 22 Doc Rev B

17 PART 5 TESTING AND ADJUSTING THE UNIT After all connections have been made to the Crown Jewel unit, power can now be applied. The "POWER ON" indicator on the lower left of the main processor board should now be lit. 1. Set Relay 1 Activation Time Figure 13. Relay Test Jumpers on Main Processor Board TB5. 1. On the Crown Jewel front panel keypad, enter " " and then the six digit programming access password. If the password is accepted, the Crown Jewel will respond with a programming promt consisting of two short beeps. The Crown Jewel comes from the factory with the password set to "000000". If you change the password during installation, make sure you write the new password down for the customer's future reference. As soon as the customer is comfortable with programming the Crown Jewel, to maintain security it is recommended that they change the password and write it down for future reference. 2. At the programming prompt, select programming step 23 and the desired relay activation time by entering "23", the 1 to 3 digit activation time of between 1 and 250 seconds, and the "#" key. For example, if you want a relay activation time of 35 seconds, at the programming prompt, enter "2335#". If the entry is accepted, the Crown Jewel will respond with two short beeps. 3. Exit the programming mode by pressing "00#". If the command is accepted, the Crown Jewel will respond with three short beeps. 4. On TB5 of the main processor board, place a jumper between the "EXIT1" and "COM" terminals (see Figure 13). 5. Verify that Relay 1 activates for the correct period of time and that the gate/door opens properly. If the gate/door does not open properly, adjust the relay activation time accordingly and re-test using steps 2 through 5, above. 2. Set Relay 2 Activation Time If you are using Relay 2 as a control relay, program the relay activation time as follows: 1. On the Crown Jewel front panel keypad, enter " " and then the six digit programming access password. If the password is accepted, the Crown Jewel will respond with a programming promt consisting of two short beeps. Rev B Doc Page 15 of 25

18 2. At the programming prompt, select programming step 24 and the desired relay activation time by entering "24", the 1 to 3 digit activation time of between 1 and 250 seconds, and the "#" key. For example, if you want a relay activation time of 35 seconds, at the programming prompt, enter "2435#". If the entry is accepted, the Crown Jewel will respond with two short beeps. 3. Exit the programming mode by pressing "00#". If the command is accepted, the Crown Jewel will respond with three short beeps. 4. On TB5 of the main processor board, place a jumper between the "EXIT2" and "COM" terminals (see Figure 13). 5. Verify that Relay 2 activates for the correct period of time and that the gate/door opens properly. If the gate/door does not open properly, adjust the relay activation time accordingly and re-test using steps 2 through 5, above. 3. Set Multiple Unit Installation Relays If your installation has multiple units, repeat procedures 1 and 2, above, as required for each unit. 4. Adjust Audio Feedback Figure 14. Feedback Pot VR2 and Speaker Volume Pot VR1. Feedback pot VR2 must be set accurately to ensure proper operation of the Crown Jewel. Set the feedback pot as follows: The factory setting is indicated by a mark on the rim of the pot. 1. On the Crown Jewel front panel keypad, enter " " and then the six digit programming access password. If the password is accepted, the Crown Jewel will respond with a programming promt consisting of two short beeps. 2. At the programming prompt, select step 30 by entering "30#". If the command is accepted, the Crown Jewel speaker will emit a tone for about 45 seconds. 3. While the tone is being emitted, adjust feedback pot VR2 on the main processor board (see Figure 14) until the tone is at its minimum level. 4. Once the tone has been set to its minimum level, press " " on the keypad to discontinue the tone. 5. Exit the programming mode by pressing the "00#". If the command is accepted, the Crown Jewel will respond with three short beeps. Page 16 of 22 Doc Rev B

19 5. Adjust Audio Volume Speaker volume pot VR1 may have to be adjusted for proper operation of the Crown Jewel. Set the speaker volume pot as follows: The factory setting is indicated by a mark on the rim of the pot. To turn the speaker volume up, turn the adjustment pot clockwise. To turn the speaker volume down, turn the adjustment pot counter-clockwise. 1. Place a call to the tenant and ask them to speak. 2. While they are speaking, listen to thecrown Jewel's speaker volume. 3. If the speaker volume is either too loud or too soft, adjust speaker volume pot VR1 on the main processor board (see Figure 14). 4. When the speaker volume is set to the desired level, end the call. 6. Verify Telephone Connections Figure 15. Bypass Board Telephone Test Points. If you have a telephone test set (also known as a "buttset") with a monitor mode, you can test the connection to the resident's telephone using the following procedure: 1. Make sure the test set is in monitoring mode. 2. Connect the test set clips to the pins marked "TELCO" on the bypass board (see Figure 15). Make sure a dial tone is emitted from the test set. 3. Connect the test set clips to the pins marked "HOME" on the bypass board (see Figure 15). Make sure a dial tone is emitted from the test set. If you do not have access to a telephone test set, test the connection to the resident's telephone as follows: 1. Have someone make a normal phone call from the resident's telephone to verify it is operating properly, then hang up the phone. 2. Press the "# " key on the Crown Jewel keypad. The telephone in the residence should ring. 3. Have someone answer the phone and dial a "9". The door/gate control relays should activate. Rev B Doc Page 17 of 25

20 7. Set Unit ID Numbers (Multiple Unit Installations Only) In a multiple unit installation, each unit must know its unit number and that there are other units in the chain. If all units are not correctly identified, remote programming and remote gate operations will not work properly. Set the unit ID numbers as follows: The unit connected to the phone line closest to the residence should be unit number 1. The unit connected to the phone line farthest from the residence and closest to the telephone company has the highest unit number. 1. On the Crown Jewel front panel keypad, enter " " and then the six digit programming access password. If the password is accepted, the Crown Jewel will respond with a programming promt consisting of two short beeps. 2. At the programming prompt, select step 38, the position of this unit in the chain, the total number of units in the chain, and the "#" sign. For example, if the unit you are currently programming is the first unit in a four unit chain, you will enter " #". 3. Repeat steps 1 and 2 at each of the remaining units. 4. After setting the unit ID numbers, verify that each unit was programmed correctly by entering "37#" on its keypad. The number of beeps emitted by each unit should match the number of that unit in the chain. If the number of beeps matches the unit number, label that unit with its unit ID number for future reference. If the beep count is the same for 2 or more units, re-enter the correct unit ID numbers for those units. 8. Hooking Up Optional CCTV Figure 16. CCTV Power Supply Board J1 Connector. 1. Plug the loose end of the coaxial cable into the monitor or television. NOTE: Maximum length of coaxial cable should not exceed 100 feet. 2. When the monitor or television is turned on, picture will appear. If picture does not appear, check the J1 connection on the CCTV power supply board. A. Make sure the connector is firmly attached to the power supply board. B. The connector is keyed and must be attached in the correct direction. From left to right, the wires should be: yellow (video); blue (ground); and red (power). C. If the wires are in reverse order, unplug the connector, turn it over, and plug it back in with the wires in the correct positions. Page 18 of 22 Doc Rev B

21 9. Complete the Installation Once you have finished testing and adjusting the Crown Jewel unit, your next step is to program the unit. For information regarding the programming of the Crown Jewel unit, refer to one of the two programming manuals were enclosed with this manual. Using the Basic Functions of the Crown Jewel System (Document Number ). Using the More Advanced Features of the Crown Jewel System (Document Number ). It is highly recommended that after programming the unit you test each feature to ensure proper installation and programming. Rev B Doc Page 19 of 25

22 APPENDIX 1 INSTALLATION PROGRAMMING MENU Each programming command begins with a 2-digit step number, followed by the required data digits, and ended by the # key. The step number tells the Crown Jewel which setting to change, and the digits contain the new value for that setting. If the step and data are valid, the unit responds with 2 short beeps. If you do not hear 2 short beeps, the unit did not understand the input. If an error is made during an entry, press the key to cancel the command. STEP PURPOSE DIGITS ACCEPTABLE INPUT 00 Exiting Programming Mode 01 Changing the Unit Password 6 02 Verifying the Unit Password 6 03 Creating an Entry Code 4, 5, or 6 4-digit entry code + relay code+time zone 04 Erasing an Entry Code 4 4-digit entry code 21 Enabling/Disabling Alarm Call 1 0=disable, 1=gate breach only, 2=keypad strikeout, 3=both 22 Setting the Alarm Call Number up to 11 00=disables the number 23 Setting Main Gate time up to 3 1 through 250 seconds 24 Setting Auxiliary Relay Time up to 3 1 through 250 seconds 26 Setting Auxiliary Relay and Status Configuration 1 0=Control (with exit request), 1=Shunt, 2=Alarm, 3=CCTV (manual), 4=CCTV (instant), 5=Control (with position sense) 27 Setting the Date and Time 11 year + month + day + day of the week + hour + minute 29 Setting the Rings Before Answer up to 2 1 through 15 rings 30 Adjusting the Sidetone Balance generate 45 second tone 31 Restoring Factory Defaults 32 Resetting the Unit 33 Enabling/disabling the No-Telco Mode 1 0=disable, 1=enable 35 Enabling Direct Commands 1 0=disable, 1=local, 2=remote, 3=both 37 Beep Unit Number 38 Setting the Unit Number 2 this unit number + total number of units 43 Overriding Telephone Company Answering Service 90 Initiate audio communication through Crown Jewel 91 Cycling the Main Gate 92 Cycling the Auxiliary Relay 93 Latching the Main Gate 94 Latching the Auxiliary Relay 95 Releasing the Main Gate 96 Releasing the Auxiliary Relay 97 Releasing Both Relays 98 Latching the Main Gate Until XXXX 4 ending time 99 Latching the Auxiliary Relay Until XXXX 4 ending time delay time in seconds + # Page 20 of 22 Doc Rev B

23 APPENDIX 2 SYSTEM RESPONSES The Crown Jewel emits various audio tones or beeps to respond to input or to indicate certain conditions. A list of the system s audio responses are as follows: 1 short beep - a key was pressed on main keypad 10 beeps (1 per second) - the talk time for a visitor call is lapsing and the unit will beep once per second for the last 10 seconds unless the talk time is extended. 2 short beeps - a programming step was valid 3 short beeps - the programming mode was exited 5 short beeps - a gate is closing by command 10 short beeps - a gate is opening by command 1 long beep - an input was not valid 2 long beeps - a duplicate entry code was entered 3 long beeps - the code memory is full 4 long beeps - the unit has reset or is powering up busy signal - the line is busy or do-not-disturb feature is in effect ring back - the unit is ringing the house continuous hi-low tones - an alarm condition has been activated silence - the keypad has struck out, or the unit is being programmed from another source, or an alarm condition exists Rev B Doc Page 21 of 25

24 FCC REQUIREMENTS The Crown Jewel system complies with Part 68 of the FCC Rules. The label affixed to this equipment contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN) for this equipment. You must, upon request, provide this information to your telephone company. The REN is useful to determine the quantity of devices you may connect to your telephone line and still have all of those devices ring when your telephone number is called. In most, but not all areas, the sum of the REN s of all devices connected to one line should not exceed five (5.0). To be certain of the number of devices you may connect to your line, as determined by the REN, you should contact your local telephone company. They will tell you what the maximum REN is for your calling area. The following jacks must be ordered from the telephone company in order to interconnect this equipment with the public communication network: None. If your Crown Jewel system causes harm to the telephone network, the Telephone Company may discontinue your service temporarily. If possible, they will notify you in advance. If advance notice is not practical, you will be notified as soon as possible. You will be informed of your right to file a complaint with the FCC. Your Telephone Company may make changes in its facilities, equipment, operations or procedures that could affect the proper functioning of your equipment. If they do you will be notified, in advance, to give you an opportunity to maintain uninterrupted telephone service. Connections to party lines are subject to state tariffs. Contact your local telephone company if you plan to use this equipment on party lines. This equipment cannot be used on public coin service lines provided by the telephone company. If you have trouble with the Crown Jewel system, please contact us at the address above for information on obtaining service or repairs. The telephone company may ask that you disconnect this equipment from the network until the problem has been corrected or until you are sure that the equipment is not malfunctioning. The maintenance section of this manual describes trouble-shooting steps which one can take in the event of equipment problems. Page 22 of 22 Doc Rev B

25 DOC REQUIREMENTS NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company's inside wiring associated with single line individual service may be extended by means of a certified connector assemble (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe unit, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the devices does not exceed 100. The Load Number for the Crown Jewel unit is 3. Rev B Doc Page 23 of 25

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM Doc. 6001051 Rev B Page 2 of 7 Doc 6001051 Rev B IMPORTANT NOTICES The Mini-Key system is a very reliable and easy to use system. However, damage could

More information

INSTALLATION INSTRUCTIONS FOR THE "LP" MODEL OVATION SYSTEM. Doc Rev B

INSTALLATION INSTRUCTIONS FOR THE LP MODEL OVATION SYSTEM. Doc Rev B INSTALLATION INSTRUCTIONS FOR THE "LP" MODEL OVATION SYSTEM Doc. 6001073 Rev B Page 2 of 31 Doc. 6001073 Rev B IMPORTANT NOTICE Make sure you know the local telephone tariff arrangements before installing

More information

Doc Rev B INSTALLATION INSTRUCTIONS FOR THE OVATION SYSTEMS

Doc Rev B INSTALLATION INSTRUCTIONS FOR THE OVATION SYSTEMS Doc.. 6001072 Rev B INSTALLATION INSTRUCTIONS FOR THE "S" AND "V" MODEL OVATION SYSTEMS IMPORTANT NOTICE Make sure you know the local telephone tariff arrangements before installing this system. In some

More information

Installation Instructions for the AUTOcard-SA System

Installation Instructions for the AUTOcard-SA System Installation Instructions for the AUTOcard-SA System IMPORTANT NOTICE The AUTOcard-SA system is a very reliable and easy to use system. However, damage could occur if it is installed incorrectly. In particular,

More information

Doc Rev B INSTALLATION INSTRUCTIONS FOR THE "NO PHONE BILL" INTERFACE

Doc Rev B INSTALLATION INSTRUCTIONS FOR THE NO PHONE BILL INTERFACE Doc - 6001003 Rev B INSTALLATION INSTRUCTIONS FOR THE "NO PHONE BILL" INTERFACE IMPORTANT NOTICES The "No Phone Bill Interface" (hereafter referred to as the "NPBI") contains static sensitive parts. To

More information

DESIGN GUIDE FOR INFINITY SYSTEMS

DESIGN GUIDE FOR INFINITY SYSTEMS Doc. 6001564 Rev B DESIGN GUIDE FOR INFINITY SYSTEMS WITH STAND ALONE OR MULTI-LINK LINK FIRMWARE TABLE OF CONTENTS 1. CABINET DIMENSIONS...3 2. WIRE CHART...3 A. CABLING TO THE MAIN PROCESSOR BOARD...

More information

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation The EntraGuard Bronze is a residential telephone keypad entry system which allows a homeowner to communicate directly with visitors and provide access by using any phone extension in the home. Because

More information

MODEL CMX-300. Technical Practice October 2015 Issue 6. Service Observing System 1. GENERAL 2. DESIGN FEATURES 3. OPERATION CONTENTS: Model CMX-300

MODEL CMX-300. Technical Practice October 2015 Issue 6. Service Observing System 1. GENERAL 2. DESIGN FEATURES 3. OPERATION CONTENTS: Model CMX-300 Model CMX-300 Technical Practice October 2015 Issue 6 MODEL CMX-300 Service Observing System 1. GENERAL 1.1 The Dees CMX-300, installed with the Dees CM-30, increases the number of stations to be observed

More information

PROGRAMMING AND USE INSTRUCTIONS FOR THE OVATION SYSTEM

PROGRAMMING AND USE INSTRUCTIONS FOR THE OVATION SYSTEM Doc. 6001012 Rev B PROGRAMMING AND USE INSTRUCTIONS FOR THE OVATION SYSTEM ALPHA COMMUNICATIONS 42 Central Drive Farmingdale NY 11735-1202 Phone: 631-777-5500 - Fax: 631-777-5599 IMPORTANT NOTICE If the

More information

Cerberus Division. Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL. (Remote Diagnostics Module)

Cerberus Division. Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL. (Remote Diagnostics Module) Cerberus Division Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL Remote Diagnostics Module INTRODUCTION The CERBERUS PYROTRONICS TM Model RDM-MXL module (RDM for connection to the MXL

More information

Telephone Entry System

Telephone Entry System Telephone Entry System TE-200-II C-0902 (PCB w/ mounting plate) 234 FISCHER AVENUE COSTA MESA, CA 92626 (714) 424-6500 (800) 840-0288 (714) 424-6510 FAX HTTP://WWW.CHANNELVISION.COM E-MAIL: SALES@CHANNELVISION.COM

More information

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries INSTRUCTION MANUAL DIGI-LOCK Keyless Entry System Installation Programming Troubleshooting BASE Industries 45 Pomona Rd. Corona, CA. 9880 Revision F TABLE OF CONTENTS OWNER REGISTRATION CARD INTRODUCTION

More information

Doc Rev B INSTALLATION INSTRUCTIONS FOR ALL. Infinity TELEPHONE ENTRY SYSTEMS (EXCEPT THOSE WITH MULTI-LINK FIRMWARE)

Doc Rev B INSTALLATION INSTRUCTIONS FOR ALL. Infinity TELEPHONE ENTRY SYSTEMS (EXCEPT THOSE WITH MULTI-LINK FIRMWARE) Doc. 6001019 Rev B INSTALLATION INSTRUCTIONS FOR ALL Infinity TELEPHONE ENTRY SYSTEMS (EXCEPT THOSE WITH MULTI-LINK FIRMWARE) TABLE OF CONTENTS IMPORTANT NOTICES...1 INSTALLATION TIPS...1 PART 1 ARRANGING

More information

Installation and Programming Instructions for the PhoneAire. Model

Installation and Programming Instructions for the PhoneAire. Model Installation and Programming Instructions for the PhoneAire Model 16-1050 1 FCC REQUIREMENTS 1. This equipment complies with Part 68 of the Federal Communications Commission Rules. On the inside panel

More information

Owner s Manual. Model 1812 Telephone Intercom Systems

Owner s Manual. Model 1812 Telephone Intercom Systems Owner s Manual Model 1812 Telephone Intercom Systems DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 1812-065 REV M, 3/07

More information

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

SuperBus 2000 Phone Interface/Voice Module Installation Instructions SuperBus 2000 Module Installation Instructions Product summary The SuperBus 2000 (PIV) Module provides phone and voice functions for the Concord, Concord 4, and Concord Express (v4) panels. The PIV module

More information

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. AREA CODE CHANGE Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. For any Paradyne telephone number that appears in this manual with an 813 area code,

More information

DIAMOND ELITE SERIES USERS GUIDE

DIAMOND ELITE SERIES USERS GUIDE DIAMOND ELITE SERIES USERS GUIDE COVERS MODELS L2-E L2S-E L2-5E L2S-5E L2-10E L2S-10E DIAMOND ELITE SERIES TELEPHONE DIAGRAM Hold Key Line 1 Line 2 Conference Key Handset Holder Ringer Volume Control Data

More information

Four IFB. Multi Line Phone Bridge. User Guide. JK Audio. Warranty

Four IFB. Multi Line Phone Bridge. User Guide. JK Audio. Warranty Warranty Four IFB is covered by a 2-year warranty to be free from defective workmanship and materials. In the event that the Four IFB needs repair, you must call us to get an authorization, and then carefully

More information

PRODUCT DESCRIPTION SPECIFICATIONS INSTALLATION. Dialer codes PRODUCT DIAGRAM. DL2 Dialer Module Digital Alarm Communicator Transmitter. Warning!

PRODUCT DESCRIPTION SPECIFICATIONS INSTALLATION. Dialer codes PRODUCT DIAGRAM. DL2 Dialer Module Digital Alarm Communicator Transmitter. Warning! PRODUCT DESCRIPTI The DL is a dialer module, which contains a Digital Alarm Communicator Transmitter (DACT). The dialer sends alarm, supervisory, and trouble information to a compatible Digital Alarm Communicator

More information

TE7210/LCD AUTODIALER Integrated Full-Page Directory/ Autodialer

TE7210/LCD AUTODIALER Integrated Full-Page Directory/ Autodialer TE7210/LCD AUTODIALER Integrated Full-Page Directory/ Autodialer INTSTALLATION & PROGRAMMING MANUAL Alpha Communiations www.alphacommunications.com 42 Central Drive Farmingdale NY 11735 Phone: 631-777-5500

More information

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 552 Series High Speed Telco Surge Protectors C E R T I F I E D An ISO-9001 Certified Company Part# 07M552-E Rev. G Revised 01/27/10 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)

More information

HomeWorks Telephone Interface. Instructions for Installation and Use Please Read Before Installing. HWI-TEL9 18 V 60 Hz 300 ma

HomeWorks Telephone Interface. Instructions for Installation and Use Please Read Before Installing. HWI-TEL9 18 V 60 Hz 300 ma Instructions for Installation and Use Please Read Before Installing General Description The HWI-TEL9 Single Line Telephone Interface provides access to up to ten different functions or events in the HomeWorks

More information

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices Owner s Manual Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com

More information

Landmark Upgrade Kit Installation Instructions

Landmark Upgrade Kit Installation Instructions Landmark Upgrade Kit Installation Instructions REMOVING THE LANDMARK BOARD 1 REMOVE POWER FROM UNIT. 2 Disconnect ALL board connections by removing the associated blue blocks (see Figure 1). Include the

More information

2GI. Touch Screen Wireless Keypad

2GI. Touch Screen Wireless Keypad 2GI Touch Screen Wireless Keypad For Remote Control of the 2GIG Security System INSTALL INSTRUCTIONS This document describes the basic installation information for the 2GIG TS1 and the steps necessary

More information

Owner s Instruction Manual

Owner s Instruction Manual Owner s Instruction Manual Advanced Healthcare Telephone Model 5150 Contents IMPORTANT SAFETY INSTRUCTIONS...3 BOX CONTENTS...4 FEATURES...4 ON/OFF SWITCH...4 DIAL BUTTONS...4 RECEIVER VOLUME CONTROL...4

More information

0 # ES&P VENTURES CORP. Engineering Services & Products

0 # ES&P VENTURES CORP. Engineering Services & Products 1 4 7 * 2 3 5 6 8 9 0 # 1 4 7 * 2 3 5 6 8 9 0 # ES&P VENTURES CORP. Engineering Services & Products SYSTEM FEATURES Capacity for up to 1000 Tenants. Simple Upgrade from Autodialer to No Telephone Line

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

SELECT ENTRY SYSTEMS

SELECT ENTRY SYSTEMS SELECT ENTRY SYSTEMS SAT2R Hands Free USER / INSTALLER MANUAL Select Engineered Systems, Inc. SAT 2R R SELECT ENTRY SYSTEMS User / Installer Guide SAT2R S elf Identifying A utomatic T elephone 2R Select

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

WS must be used in a temperature controlled place. It is compliant to ETS Class T

WS must be used in a temperature controlled place. It is compliant to ETS Class T Important Information about the Sagemcom F@ST 2705 WS: Operational working: F@ST2705 WS must be used in a temperature controlled place. It is compliant to ETS 300 019-1-3 Class T 3.2 standard: 1. Temperature

More information

Telephone Switch Module. Model# TSM-1. User Guide. Santa Clara, CA (800) (972)

Telephone Switch Module. Model# TSM-1. User Guide. Santa Clara, CA (800) (972) Telephone Switch Module Model# TSM-1 User Guide Santa Clara, CA 95050 1(800) 879-8585 1(972)578-1699 DESCRIPTION The Telephone Switch Module (TSM-1) allows any touch-tone phone to control lights. The TSM

More information

Open Applications Interface (OAI) Installation and Setup

Open Applications Interface (OAI) Installation and Setup Open Applications Interface (OAI) Installation and Setup Link Wireless Telephone System Link 3000 MCU Part Number: 72-0059-07 Issue A NOTICE SpectraLink Corporation has prepared this document for use by

More information

Big button Speakerphone MODEL: FC-8814

Big button Speakerphone MODEL: FC-8814 FUTURE CALL Big button Speakerphone MODEL: FC-8814 USER MANUAL Please follow instructions for repairing if any otherwise do not alter or repair any parts of device except specified. IMPORTANT SAFETY INSTRUCTIONS

More information

G.SHDSL NTU with Fixed Serial Interfaces

G.SHDSL NTU with Fixed Serial Interfaces DECEMBER 2006 ME231A ME232A ME233A G.SHDSL NTU with Fixed Serial Interfaces CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support,

More information

UT3620 Triple NT1 Installation Guide

UT3620 Triple NT1 Installation Guide UT3620 Triple NT1 Installation Guide UT3620 Triple NT1 Installation Guide Revision 1.00 1/3/2000 Information in this guide is subject to change without notification. Copyright 2000 Alpha Telecom, Inc.

More information

INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS)

INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY L DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY L SYSTEMS) Doc. 6001025 Rev B INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS) Rev. B Doc. 6001025 Page 1 of 13 IMPORTANT NOTICE This document covers

More information

Model MUGAPLM Multi-Unit Gate Access Panel. MUGAPLM Installation & Assembly

Model MUGAPLM Multi-Unit Gate Access Panel. MUGAPLM Installation & Assembly Model MUGAPLM Multi-Unit Gate Access Panel Overview The Multi-Unit Gate Access Panel (MUGAPLM) uses a digitally secure intercom link that allows it to control up to four gate operators and other accessories.

More information

Area of Rescue Command Unit Installation Instructions Model AOR-8 / Model AOR-16

Area of Rescue Command Unit Installation Instructions Model AOR-8 / Model AOR-16 THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED CE PRODUIT DOIT ÊTRE

More information

Installation OVERVIEW

Installation OVERVIEW Installation OVERVIEW The DEMCO GATE ACCESS CONTROL SYSTEM is designed to operate up to 4 gates, each with an IN KEYPAD and/or an OUT KEYPAD. Each gate is wired as illustrated in the drawing of a "TYPICAL

More information

CROWN JEWEL SOFTWARE FOR WINDOWS SOFTWARE REV.

CROWN JEWEL SOFTWARE FOR WINDOWS SOFTWARE REV. CJWin CROWN JEWEL SOFTWARE FOR WINDOWS SOFTWARE REV. 2.20 Crown Jewel (with Camera) Crown Jewel (Brass Enclosure) User s Guide TABLE OF CONTENTS Getting Started System Requirements.................................3

More information

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT MODEL INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT A. GENERAL. The Federal Model is a solid-state

More information

VOICE and/or DATA CELLULAR SYSTEM

VOICE and/or DATA CELLULAR SYSTEM ... VOICE and/or DATA CELLULAR SYSTEM This cellular device cannot be used for 9 calls. The Voice/Data or Data Only Cellular System operates on DoorKing s cellular network that is hosted on the AT&T G LTE

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

BIG BUTTON PHONE WITH ONE TOUCH DIALING AND

BIG BUTTON PHONE WITH ONE TOUCH DIALING AND FUTURE CALL LLC BIG BUTTON PHONE WITH ONE TOUCH DIALING AND 40db HANDSET VOLUME MODEL: FC-1507 USER MANUAL Please follow instructions for repairing if any otherwise do not alter or repair any parts of

More information

Owner s Manual. 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems

Owner s Manual. 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems Owner s Manual 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586

More information

GN 4170 headset telephone Hands-free ease with sleek, space-saving phone

GN 4170 headset telephone Hands-free ease with sleek, space-saving phone For more information and technical specifications: www.gnnetcom.com CORPORATE HEADQUARTERS Northeastern Blvd. Nashua, NH 002 1-00-2-1-0--1100 Fax: 1-0--1122 2002 GN Netcom, Inc. All rights reserved. -0A

More information

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

WIRESPEED ADSL MODEM (MODEL 2000) User Guide WIRESPEED ADSL MODEM (MODEL 2000) User Guide Copyright 2001 Westell, Inc. All rights reserved. 030-300187 Rev. A Printed in the United States of America December 2001 CONTENTS 1. PRODUCT DESCRIPTION...

More information

Trademark Generation II Series Intercom System Installation and Operation Reference Guide

Trademark Generation II Series Intercom System Installation and Operation Reference Guide Trademark Generation II Series Intercom System Installation and Operation Reference Guide www.escoservices.com Components: Desktop Controller, Digital Interface Box, -Speaker I/O Card, 9VDC Power Supply

More information

VOICE and/or DATA CELLULAR SYSTEM

VOICE and/or DATA CELLULAR SYSTEM ... VOICE and/or DATA CELLULAR SYSTEM The Voice/Data or Data Only Cellular System operates on DoorKing s cellular network that is hosted on the AT&T G LTE network where available. The system provides voice

More information

PICTURE PHONE WITH ONE TOUCH DIALING MODEL: FC-0613

PICTURE PHONE WITH ONE TOUCH DIALING MODEL: FC-0613 FUTURE CALL PICTURE PHONE WITH ONE TOUCH DIALING MODEL: FC-0613 USER MANUAL Please follow instructions for repairing if any otherwise do not alter or repair any parts of device except specified. IMPORTANT

More information

G.SHDSL NTU DECEMBER 2006 LB510A

G.SHDSL NTU DECEMBER 2006 LB510A DECEMBER 2006 LB510A G.SHDSL NTU CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500

More information

NT1B-300 Rack Installation Instructions

NT1B-300 Rack Installation Instructions The NT1B-300 Rack houses 24 Tone Commander NT1B-300TC ISDN Network Terminations in a 19 rack, 23 rack, or wall mount configuration. The rack is also compatible with Lucent NT1B-300 NT1s. The rack supplies

More information

SuperLine IAD Models 6501, 6502, 6510, 6511, and 6512 Installation Instructions

SuperLine IAD Models 6501, 6502, 6510, 6511, and 6512 Installation Instructions 6512 PWR ALM TST LINE ETHERNET SuperLine IAD Models 6501, 6502, 6510, 6511, and 6512 Installation Instructions Document Number 6500-A2-GN10-00 September 1999 SuperLine TM IAD Front View Rear View BASE

More information

Telephone Line Monitor USER GUIDE

Telephone Line Monitor USER GUIDE Telephone Line Monitor USER GUIDE For Technical Assistance call the Manufacturers direct Ph 800 530 8645 8AM - 5PM West Coast Pacific Time NATCOMM USA LLC Responsible Supplier Code NC OPERATION Our Telephone

More information

TCM-1 Beamtracking Ceiling Microphone TCM-1A Beamtracking Ceiling Microphone with Amplifier TCM-1EX Beamtracking Expansion Ceiling Microphone

TCM-1 Beamtracking Ceiling Microphone TCM-1A Beamtracking Ceiling Microphone with Amplifier TCM-1EX Beamtracking Expansion Ceiling Microphone TCM-1 Beamtracking Ceiling Microphone TCM-1A Beamtracking Ceiling Microphone with Amplifier TCM-1EX Beamtracking Expansion Ceiling Microphone OPERATION MANUAL APRIL 2018 TCM-1, TCM-1A & TCM-1EX PRODUCT

More information

2000 Series e/em Style Keypad Installation and Programming Manual

2000 Series e/em Style Keypad Installation and Programming Manual 2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

SmartLock Controller INSTALLATION MANUAL

SmartLock Controller INSTALLATION MANUAL SmartLock Controller INSTALLATI MANUAL November 2015 Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting...

More information

Heavy Duty Ringdown/Autodialer Telephone Panel Insert

Heavy Duty Ringdown/Autodialer Telephone Panel Insert Heavy Duty Ringdown/Autodialer Telephone Panel Insert (Replaces Insert in Northern Telecom and Guardian Telecom Enclosures) Installation & Operation Guardian Telecom Inc. www.guardiantelecom.com Guardian

More information

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment. SECTION 26 43 00 SURGE PROTECTION DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment. 1.2 DEFINITIONS A. ATS:

More information

Click Save to return to the main Setup screen.

Click Save to return to the main Setup screen. ON-SITE Setup Guide Thank you for purchasing the ON-SITE. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

Version 4.6 Firmware DA2002. Includes Instructions on Installation, Programming, & Troubleshooting

Version 4.6 Firmware DA2002. Includes Instructions on Installation, Programming, & Troubleshooting Version 4.6 Firmware DA2002 Includes Instructions on Installation, Programming, & Troubleshooting 2002 G-TEL Enterprises, Inc. TABLE OF CONTENTS INTRODUCTION... 2 YOUR PAYPHONES PROGRAMMING...2 SPECIAL

More information

NCH-1000 (Multiple Breaker Types) Installation Instructions

NCH-1000 (Multiple Breaker Types) Installation Instructions 20M1 12345678 NCH-1000 (Multiple Breaker Types) Installation Instructions DOC. #560502100 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance

More information

212iL Rev. 1.1

212iL Rev. 1.1 212iL 1 International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iL (illuminated Luxury) Keypad Single Unit Keypad- Control Installation Manual Features: 120 User Capability Illuminated

More information

Chapter 2. Installing the Chapter 2. Contents

Chapter 2. Installing the Chapter 2. Contents Contents Chapter 2 Installing the 3512 Overview... 2-2 Unpacking... 2-2 Telephone Equipment... 2-3 Customer-Provided Telephone Equipment... 2-3 Telephone Company Procedures and Regulatory Requirements...

More information

Area of Refuge Command Unit Installation Instructions Model AOR-24/AOR-32

Area of Refuge Command Unit Installation Instructions Model AOR-24/AOR-32 THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED CE PRODUIT DOIT ÊTRE

More information

DS1 USER GUIDE. For Technical Assistance call the Manufacturers direct Ph AM - 5PM West Coast Pacific Time

DS1 USER GUIDE. For Technical Assistance call the Manufacturers direct Ph AM - 5PM West Coast Pacific Time DS1 USER GUIDE For Technical Assistance call the Manufacturers direct Ph 800 530 8645 8AM - 5PM West Coast Pacific Time NATCOMM USA LLC Responsible Supplier Code :NC TABLE OF CONTENTS Description Pages

More information

Installation/Owner s Manual

Installation/Owner s Manual Installation/Owner s Manual Model 1812 Plus Residential Telephone Intercom/Access Control System Use this manual for circuit board 1971-1 Revision U or higher. Control a main door and gate. 4 2 3 5 6 1

More information

Owner s Manual. 1803, 1808, 1810 Telephone Entry Systems

Owner s Manual. 1803, 1808, 1810 Telephone Entry Systems Owner s Manual 1803, 1808, 1810 Telephone Entry Systems DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 1800-060 REV M, 8/08

More information

CO-485USB USB to RS-485 CONVERTER TECHNICAL REFERENCE

CO-485USB USB to RS-485 CONVERTER TECHNICAL REFERENCE TABLE OF CONTENTS CO-485USB USB to CONVERTER TECHNICAL REFERENCE Specifications, Description and Technical Support... page 1 Connection Diagram... page 2 Set-Up & Testing... page 3 & 4 Power Supply Shunts...

More information

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

INSTALLATION INSTRUCTIONS Model 930 EntryCheck SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 930 EntryCheck

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Clipsal Bus Couplers Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Instruction Bulletin Retain for future use. Clipsal Bus Couplers 63249-420-236A2 Instruction

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

TruPortal Dual Door Interface Module Quick Reference

TruPortal Dual Door Interface Module Quick Reference TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers

More information

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014 SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions

More information

Automatic Phone-Out Home Monitoring System

Automatic Phone-Out Home Monitoring System Automatic Phone-Out Home Monitoring System Freeze Alarm Model Number: THP217 Product Description This product is intended to monitor homes, cabins, and other premises for low temperature conditions. It

More information

Enterprise Session Border Router, IAD

Enterprise Session Border Router, IAD SmartNode 5480/5490 Series Enterprise Session Border Router, IAD Quick Start Guide This is a Class A device and is not intended for use in a residential environment. Part Number: 07MSN5480-90-QS, Rev.

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

CIB 3125 (122A) Off-Premises Range Extender. Installation Instructions. Installed By Qualified Technician Only CIB

CIB 3125 (122A) Off-Premises Range Extender. Installation Instructions. Installed By Qualified Technician Only CIB CIB 3125 (122A) Off-Premises Range Extender Installation Instructions Installed By Qualified Technician Only CIB 3125 106793441 1992 AT&T All Rights Reserved Printed in USA Issue 3 August 1992 NOTICE Every

More information

2N Telecommunications H.I.M. USER GUIDE Helios Interface Module

2N Telecommunications H.I.M. USER GUIDE Helios Interface Module 2N Telecommunications H.I.M. USER GUIDE Helios Interface Module PRODUCT DESCRIPTION The Helios Interface Module (HIM) is designed to connect the Helios Door Phone device to all telephones connected to

More information

PAGEPAC 6 V INSTALLATION There are several ways to connect PagePac 6 to your telephone system.

PAGEPAC 6 V INSTALLATION There are several ways to connect PagePac 6 to your telephone system. PagePac by Issue 2 PAGEPAC 6 V-5323006 INTRODUCTION PagePac 6 is a compact, 6 watt, voice-paging system that integrates single-zone paging capability to your telephone system. Dimensions/Weight 6.0 W x

More information

3228 Station Port FXS Doorphone

3228 Station Port FXS Doorphone 3228 Station Port FXS Doorphone Installation and User Guide Algo Communication Products Ltd., Burnaby, BC Canada V5J 5L2 280817-1 www.algosolutions.com - 1 - Document #: 90-00059C Important Safety Notice

More information

Interchange LTD. JK Audio. Intercom Phone Bridge + Digital Hybrid. User Guide

Interchange LTD. JK Audio. Intercom Phone Bridge + Digital Hybrid. User Guide Interchange LTD Intercom Phone Bridge + Digital Hybrid User Guide JK Audio Welcome Thank You Thank you for purchasing a JK Audio Interchange LTD Intercom Phone Bridge. Please read this guide for instructions

More information

PARTNER Contact Closure Adjunct

PARTNER Contact Closure Adjunct Closure Installation Instructions BEFORE STARTING INSTALLATION, READ AND UNDERSTAND ALL SAFETY INSTRUCTIONS ON PAGE. The is used with a Advanced Communications System processor module (available separately)

More information

Installation Manual & User Instructions. MultiCom 500

Installation Manual & User Instructions. MultiCom 500 Installation Manual & User Instructions For MultiCom 500 Multi resident GSM Intercom System Contents Section Description Page 1 Introduction 3 2 Getting started 3 3 SIM card 3 4 Wiring 4 5 Keypad / onscreen

More information

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It

More information

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE WPP-531-D OR SSP-511-D-SPK1.07UNVLr1-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE OR MODEL SSP-511-D STAINLESS STEEL PANEL TELEPHONE WITH OPTIONAL ADA

More information

Four-Line Intercom/ Speakerphone 954

Four-Line Intercom/ Speakerphone 954 1 USER S MANUAL Part 2 Four-Line Intercom/ Speakerphone 954 Please also read Part 1 Important Product Information AT&T and the globe symbol are registered trademarks of AT&T Corp. licensed to Advanced

More information

OPAL 1010S. The Teledex one-line. speakerphone specifically MANUAL OWNER S. designed for the international. hospitality industry.

OPAL 1010S. The Teledex one-line. speakerphone specifically MANUAL OWNER S. designed for the international. hospitality industry. OPAL 1010S The Teledex one-line MANUAL OWNER S speakerphone specifically designed for the international hospitality industry. INCLUDED IN YOUR PACKAGE Handset Base Unit Coiled Handset Cord Line Cord Clear

More information

Owner s Manual. 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems

Owner s Manual. 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems Owner s Manual 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-45-0023 Fax: 310-41-158

More information

HOUSING DEVICES, INC. HDI ADA - ARCU. Installation & Operations Manual. Made in the USA

HOUSING DEVICES, INC. HDI ADA - ARCU. Installation & Operations Manual. Made in the USA HOUSING DEVICES, INC. ADA - ARCU Installation & Operations Manual Made in the USA ADA - ARCU 5 & 10 Pre-Installation Requirements: For each ADA-1000 in the elevator you must run a twisted, shielded, 22

More information

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07) DP2 DOOR PHONE For Technical Assistance Please Phone: (07) 5596 5128 TABLE OF CONTENTS Description Page 3 Door Phone Dimensions Page 4 Door Phone Range Page 5 Door Phone Performance Page 6 Operation Summary

More information

DP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time

DP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time DP2 Door Phone For Technical Assistance call the Manufacturers direct ph 0800 530 8645 9AM - 5PM West Coast Pacific Time NATCOMM USA LLC Supplier Code : NC TABLE OF CONTENTS Description Page 3 Door Phone

More information

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016 PS 150 SINGLE CHANNEL TELEPHONE INTERFACE USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you 1 of 6 START HERE 1 Carefully unpack box. 2 Make sure you have everything shown here. 3 Unlock and remove front panel of keypad unit, then using carriage bolts and hex nuts, attach unit to pedestal as

More information

Installation/Owner s Manual

Installation/Owner s Manual Installation/Owner s Manual Model 1812 Classic Residential Telephone Intercom/Access Control System Use this manual for circuit board 1871-1 Revision S or higher. 1812-65-U-12-13 Control a main door and

More information