ACCESS CONTROL STARTER KIT HARDWARE INSTALLATION GUIDE

Size: px
Start display at page:

Download "ACCESS CONTROL STARTER KIT HARDWARE INSTALLATION GUIDE"

Transcription

1 ACCESS CONTROL STAR KIT HARDWARE INSTALLATION GUIDE

2 READ THIS BEFORE YOU START This document contains a lot of useful information to help you install and configure the Stanley Starter and Expansion Kit as effectively as possible. If you cannot read the entire document then at least take note of the points in the box below - Thank You. IMANT POINTS: Check the power supply voltage for each unit. It is factory set to 2V. If you are using 24V locks then set the jumper on the power supply to 24V. If you set the power supply to 24V then make sure the readers you are using will operate at that voltage. The GS3 readers supplied in these kits will work, but other readers may not. You may need to use an extra power supply. Review the reader wiring for the GS3 readers you may not be familiar with the PAC signal connection that only requires one data conductor. Make sure you have the Stanley Screwdriver supplied with the Starter Kit, it is the correct size for the reader terminal block screws Check the current PC Operating System requirements before attempting to install the Stanley PAC software. Supported operating systems are listed at WHAT ELSE DO I NEED? A Windows PC computer. A network to connect to the PAC 52IP (Existing or one you install). Locks for the controlled doors. These could be strikes or mag locks, or they could be barriers or gates. Optional door contacts and request-to-exit devices. Backup batteries there is room in the enclosure for one 2v 7Ah or two 2v 4.5Ah. Wiring Requirement RS CAT5 or CAT6 cable Readers - 22AWG 4-Conductor, Unshielded and Stranded STEP INSTALLATION - TEST MODE TESTING One Person Installation Testing at the Door. Press the door controller s One Touch button for 4 seconds to activate test mode for one hour. All the readers attached to this controller will latch from red to green. All feedback is provided by the reader. To exit hold 'One Touch' button for 4 seconds or it will time out after hour. Present this card to the Entry Reader. Reader will flash from green to red once and the lock will release. Present this card to the Exit Reader. Reader will flash from green to red twice and the lock will release. Operate the Request-to-Exit (/REX). Reader will flash from green to red three times. Open the Door Contact. Reader will flash from green to red four times. Default state STEP - TEST MODE INSTALLATION TESTING One Person Installation Testing at the Door. Press the door controller s One Touch button for 4 seconds to activate test mode for one hour. All the readers attached to this controller will latch from red to green. All feedback is provided by the reader. To exit hold 'One Touch' button for 4 seconds or it will time out after hour. Present this card to the Entry Reader. Reader will flash from green to red once and the lock will release. Present this card to the Exit Reader. Reader will flash from green to red twice and the lock will release. Operate the Request-to-Exit (/REX). Reader will flash from green to red three times. Open the Door Contact. Reader will flash from green to red four times. The One-Touch Test Mode card included with each Starter Kit, enables the testing of all door hardware by just one person, at the door. Default state

3 Hardware Installation WHAT S IN THE BOX? Congratulations on choosing the Stanley PAC Two-Door Starter Kit access control and security solution. This Installation Manual explains how to install the Starter Kit hardware. The Two-Door Starter Kit controls two sets of door devices (such as two-doors, two-readers and door contact inputs) with Card In/Card Out (a reader on both sides of the same door). Up to 23 Stanley Expansion Kits can be connected to each Starter Kit using RS-485, enabling control of 48 doors. STANLEY STAR KIT STANLEY EXPANSION KIT Controller INPUT: ; 0.8A (CONTROLLER ONLY) RX RS-232 DTR includes: Metal Enclosure Power Supply 2-Door Controller CTS TX Serial No. PAC Part No. Serial No. PAC Part No. INSP E/BOND TESTED HIP OT BURN MOD LEVEL INSP F/INPS FLASHING MAINS ONLY STEADY MAINS & BATTERY E/BOND TESTED HIP OT BURN MOD LEVEL GLU/LID F/INPS GLU/LID MAX OUTPUT POWER : MAX OUTPUT POWER : MAX INPUT CURRENT : MAX INPUT CURRENT : MAINS INPUT VOLTAGE : VAC 47-63Hz MAINS INPUT VOLTAGE : VAC 47-63Hz DANGER DO T CONNECT TO MAINS SUPPLY UNTIL CORRECTLY INSTAL FLASHING MAINS ONLY MAINS & BATTERY STEADY DANGER DO T CONNECT TO MAINS SUPPLY UNTIL CORRECTLY INSTAL Boxed Stanley PAC 52IP Boxed Stanley PAC 52 2x Stanley GS3 Readers 2x Stanley GS3 Readers Readers Windows PC Software Stanley PAC Access Lite Edition on USB Flash Drive USB Admin Reader includes USB Cable and Driver Stanley GS3 USB Admin Reader Key Fobs Stanley Key fobs - 0 Pack Non Secure side Secure side 52IP Access Controller STANLEY PAC USB Stick ➋ Door contact DTR RX CTS TX Serial No. PAC Part No. ➌ Mullion Reader SEA RECHARGEABLE LEAD-ACID BATTERY 2V BATTERY REX ➊ ➎ Key Fob LAN Windows PC Admin Reader ➍

4 STAR KIT PNTS The Starter Kit consists of the following equipment: ➊ STANLEY PAC ACCESS LITE EDITION SOFTWARE. Stanley PAC Access software is designed to run on Windows PC with Windows 0, Windows 8. or Windows 7 operating system. Support is also available for Windows Server, SQL Server and Virtual Machine installations. Refer to for complete information. The Lite Edition will organise and report on up to 5,000 users and 28 doors. There are four versions of the software, a simple software activation key is all that required to upgrade from version to version. ADV PRO 5

5 INSP E/BOND TESTED HIP OT BURN F/INPS MAX OUTPUT POWER : MAX INPUT CURRENT : MAINS INPUT VOLTAGE : VAC 47-63Hz FLASHING MAINS ONLY STEADY MAINS & BATTERY Serial No. PAC Part No. DANGER DO T CONNECT TO MAINS SUPPLY UNTIL CORRECTLY INSTAL GLU/LID TERM IN OUT N N0 NGND OVRD VIN LOCK TX RX TX RX ADMIN INPUT: ; 0.22A (CONTROLLER + 4 S) CAUTION - FIXED INTERNAL BATTERY See manual for disposal of unit. This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions: () this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation Manufacture Date One-Touch Testing To enter View Mode press the One-Touch button momentarily. To enter Active Mode press and hold the One-Touch button for 2 to 4 seconds. To leave One-Touch testing, press the button momentarily again. Note that One-Touch Active mode will automatically time out after hour. For details of One-Touch modes see the enclosed Quick Start Guide. Made in UK SEA RECHARGEABLE LEAD-ACID BATTERY SIGNAL VOLTAGE 2/24V 5V DATA DOOR 2 DOOR2 SEA RECHARGEABLE LEAD-ACID BATTERY STAR KIT PNTS ➋ TWO-DOOR CONTROLLER (PAC 52IP WITH 3A POWER SUPPLY/CHARGER IN METAL ELOSURE) Both the Starter Kit and Expansion Kit are supplied with a Two-Door Controller mounted on stand-offs, tamper switch and 3A 2 or 24V switchable power supply, enclosed in a lockable cabinet with two keys. The power supply/charger provides power for the controller providing access control for up to two doors, with four readers (Entry/Exit) and most locks. 5Year Warranty There is space for one 2V, 7AHr or two 2V 4.5AHr (wired in series) sealed lead-acid batteries. These provide standby backup power, depending upon system configuration and activity. The power supply has deep discharge protection, and provides a Low Battery signal to the panel. Replace the batteries every 2 to 3 years, or more often if the system has a high rate of backup use. 0.2 A MAX RS-485 MOD LEVEL TCP/IP POWER ACCESS AC 52 IP Mk. 2 Access Controller 2V BATTERY DOOR 0.2 A MAX DOOR 2 LOCK 2 LOCK RELAY 30 V; 5A RELAY 2 30 V; 5A 2V BATTERY ELOSURE The enclosure is 3.5 inches wide, 3.5 inches high, 3.5 inches deep. The Door Controller is mounted directly to the enclosure with stand-offs. All the Stanley PAC 52 series controllers and Stanley GS3 Readers can be powered from a supply between 0.5 and 28V. CURRENT CONSUMPTION PAC 52 & 52IP Readers Locks Other Devices 220mA GS3 Mullion 00mA (0.A) per reader. Reader power is limited to 200mA per door. Check the manufacturer's data sheet. Check current consumption of any other devices such as motion s if they are to be powered from the same supply. The reader power supply voltage is the same as the input voltage. If you are using a 24V supply to power the 52 door controller and not using Stanley GS3 readers, make sure the readers are capable of being powered at this voltage. 6

6 STAR KIT PNTS ➌ STANLEY GS3 MULLION PROXIMITY Perfect for narrow rail mullion installations and can be used as an unobtrusive unit for standard wall mounted reader applications..9in.in The reader uses one screw to attach the reader to the mounting bracket, allowing easy mounting indoors or out. SUPS 2 24 OR VOLTS Each reader is outfitted with an integrated piezo buzzer, bicolor and has a read range of up to 3 in. 4.in.8in.07in 0.98in 3.96in 3.27in 0.79in 0.70in.63in ➍ STANLEY GS3 USB ADMIN The USB Admin Reader is designed to to sit next to the Host or a Client PC and connected with the supplied USB cable to a USB port. This reader is designed to ease the task of enrolling credentials. Card numbers are read directly into the Stanley PAC Access database. 3.46in..22in. Additional workstations can also have Enrollment Readers. The Lite Edition supports 2 clients, but more can be added with a software license upgrade. 5.2in. 7

7 STAR KIT PNTS ➎ STANLEY PROXIMITY KEY FOBS, BOX OF 0 Robust, world-class construction combined with advanced technology and a pre-programmed unique identification number without site codes, makes programming easy and copying almost impossible. Every key fob is manufactured using a highly sophisticated process. Ultrasonic welding closes the housing, ensuring a highly reliable product. The passive proximity technology in the key fob requires no batteries or physical contact with the reader; this helps assure that the key fobs are virtually wear-free and will provide years of service with no maintenance..3in. 0.24in. 2.36in. STANLEY PROXIMITY ISO PROXIMITY CARDS, PACK OF 0 ** Not supplied with the Starter Kit. ADI # 7S-STCARD The Stanley ISO Proximity Card offers proximity technology with photo identification capability on a single card. It is ISO 780 compliant, with a nominal thickness of.030", the same size and thickness as a standard credit card. The card features a graphics quality surface optimized for Photo ID printing and vertical or horizontal slot punch capability in. 2.25in in ± 0. 8

8 DOOR TX RX TX RX IN OUT DOOR TX RX TX RX IN OUT N N DOOR TX RX TX RX IN OUT RS A MAX N0 NGND RS A MAX N0 NGND N RS A MAX N0 NGND DOOR LOCK RELAY 0.2 A MAX DOOR 2 LOCK 2 CAUTION - FIXED INTERNAL BATTERY See manual for disposal of unit. OVRD This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions: () this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation TCP/IP DOOR LOCK RELAY 0.2 A MAX DOOR 2 LOCK 2 CAUTION - FIXED INTERNAL BATTERY See manual for disposal of unit. OVRD This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions: () this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation TCP/IP POWER POWER RELAY 2 ACCESS VIN LOCK RELAY 2 ACCESS VIN LOCK DOOR LOCK RELAY 0.2 A MAX DOOR 2 LOCK 2 CAUTION - FIXED INTERNAL BATTERY See manual for disposal of unit. OVRD This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions: () this device may not cause harmful interference, and (2) this device must TCP/IP accept any interference received, including interference that may cause undesired operation POWER RELAY 2 ACCESS VIN LOCK 2 2/24V 5V DOOR2 DATA 2 2/24V 5V DOOR2 DATA 2 2/24V 5V DOOR2 DATA DOOR TX RX TX RX IN OUT N RS A MAX N0 NGND DOOR TX RX TX RX IN OUT N RS A MAX N0 NGND DOOR LOCK RELAY 0.2 A MAX DOOR 2 LOCK 2 CAUTION - FIXED INTERNAL BATTERY See manual for disposal of unit. OVRD This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions: () this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation RS-232 DTR RX CTS TX DOOR LOCK RELAY 0.2 A MAX DOOR 2 LOCK 2 CAUTION - FIXED INTERNAL BATTERY See manual for disposal of unit. OVRD This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions: () this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation RS-232 DTR RX CTS TX POWER RELAY 2 ACCESS VIN LOCK 2 2/24V 5V DOOR2 DATA DOOR TX RX TX RX IN OUT N RS A MAX N0 NGND DOOR LOCK RELAY 0.2 A MAX DOOR 2 LOCK 2 CAUTION - FIXED INTERNAL BATTERY See manual for disposal of unit. OVRD This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions: () this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation RS-232 DTR RX CTS TX POWER RELAY 2 ACCESS VIN LOCK 2 2/24V 5V DOOR2 DATA INSTALLATION PAC 52IP There two typically site layouts, using Stanley PAC 52-series Two-Door Controllers. The Starter Kit acts as the TCP/IP gateway for a RS485 multi-drop of Two-Door Expansion Kits. Up to 23 Expansion Kits can be added to give a maximum of 24 controllers with 48 doors on a single bus. LAN/WAN PAC 52IP 2 DOOR CONTROLLER (STAR KIT) ADMIN TERM INPUT: ; 0.22A (CONTROLLER ONLY) Made in UK PAC 52IP Mk. II Access Controller X Date Code One-Touch Testing To enter View Mode press the One-Touch button momentarily. To enter Active Mode press and hold the One-Touch button for 2 to 4 seconds. To leave One-Touch testing, press the button momentarily again. Note that One-Touch Active mode will automatically time out after hour. For details of One-Touch modes see the enclosed Quick Start Guide. SIGNAL VOLTAGE PAC 52 2 DOOR CONTROLLER (EXPANSION KIT) ADMIN TERM INPUT: ; 0.22A (CONTROLLER ONLY) Made in UK PAC 52 Mk. II Access Controller X Date Code One-Touch Testing To enter View Mode press the One-Touch button momentarily. To enter Active Mode press and hold the One-Touch button for 2 to 4 seconds. To leave One-Touch testing, press the button momentarily again. Note that One-Touch Active mode will automatically time out after hour. For details of One-Touch modes see the enclosed Quick Start Guide. SIGNAL VOLTAGE PAC 52 2 DOOR CONTROLLER (EXPANSION KIT) ADMIN TERM INPUT: ; 0.22A (CONTROLLER ONLY) Made in UK PAC 52 Mk. II Access Controller X Date Code One-Touch Testing To enter View Mode press the One-Touch button momentarily. To enter Active Mode press and hold the One-Touch button for 2 to 4 seconds. To leave One-Touch testing, press the button momentarily again. Note that One-Touch Active mode will automatically time out after hour. For details of One-Touch modes see the enclosed Quick Start Guide. SIGNAL VOLTAGE UP TO 24 CONTROLLERS [TOTAL] (RS-485 MUNICATIONS) DOOR DOOR TWO DOOR DOOR TWO DOOR DOOR TWO 2. Larger systems spread across several sites can be created by using multiple network connections PAC 52IP 2 DOOR CONTROLLER (STAR KIT) TERM ADMIN INPUT: ; 0.22A (CONTROLLER ONLY) POWER RELAY 2 ACCESS VIN LOCK One-Touch Testing To enter View Mode press the One-Touch button momentarily. To enter Active Mode press and hold the One-Touch button for 2 to 4 seconds. To leave One-Touch testing, press the button momentarily again. Note that One-Touch Active mode will automatically time out after hour. For details of One-Touch modes see the enclosed Quick Start Guide. Made in UK PAC 52IP Mk. II Access Controller X Date Code 2 SIGNAL VOLTAGE 2/24V 5V DOOR2 DATA TERM IN OUT TX RX TX RX CAUTION - FIXED INTERNAL BATTERY See manual for disposal of unit. This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions: () this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation Made in UK 2/24V 5V DATA DOOR TX RX TX RX IN OUT N RS A MAX N0 NGND DOOR LOCK RELAY 0.2 A MAX DOOR 2 LOCK 2 CAUTION - FIXED INTERNAL BATTERY See manual for disposal of unit. OVRD This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions: () this device may not cause harmful interference, and (2) this device must TCP/IP accept any interference received, including interference that may cause undesired operation DOOR 2 DOOR2 POWER RELAY 2 ACCESS VIN LOCK 2 2/24V 5V DOOR2 DATA PAC 52 2 DOOR CONTROLLER (EXPANSION KIT) TERM ADMIN INPUT: ; 0.22A (CONTROLLER ONLY) Made in UK PAC 52 Mk. II Access Controller X Date Code One-Touch Testing To enter View Mode press the One-Touch button momentarily. To enter Active Mode press and hold the One-Touch button for 2 to 4 seconds. To leave One-Touch testing, press the button momentarily again. Note that One-Touch Active mode will automatically time out after hour. For details of One-Touch modes see the enclosed Quick Start Guide. SIGNAL VOLTAGE Location One DOOR DOOR TWO DOOR DOOR TWO PAC 52IP 2 DOOR CONTROLLER (STAR KIT) LAN/WAN ADMIN TERM INPUT: ; 0.22A (CONTROLLER ONLY) Made in UK PAC 52IP Mk. II Access Controller X Date Code One-Touch Testing To enter View Mode press the One-Touch button momentarily. To enter Active Mode press and hold the One-Touch button for 2 to 4 seconds. To leave One-Touch testing, press the button momentarily again. Note that One-Touch Active mode will automatically time out after hour. For details of One-Touch modes see the enclosed Quick Start Guide. SIGNAL VOLTAGE Location Three DOOR DOOR TWO HOST PC USB ADMIN ADMIN TERM INPUT: ; 0.22A (CONTROLLER ONLY) Made in UK PAC 52IP Mk. II Access Controller X Date Code One-Touch Testing To enter View Mode press the One-Touch button momentarily. To enter Active Mode press and hold the One-Touch button for 2 to 4 seconds. To leave One-Touch testing, press the button momentarily again. Note that One-Touch Active mode will automatically time out after hour. For details of One-Touch modes see the enclosed Quick Start Guide. SIGNAL VOLTAGE Location Two DOOR DOOR TWO PAC 52IP 2 DOOR CONTROLLER (STAR KIT) ADMIN N N0 NGND RS-485 INPUT: ; 0.22A (CONTROLLER + 4 S) 0.2 A MAX WORK CONNECTION The PAC 52IP controller can connect direct to the local network. Use a Cat 5 or Cat 6 patch cord. The distance from the PAC 52IP to the network outlet should be no longer than 30 feet. CAT 5 patch cord Max. 33 feet to outlet OVRD TCP/IP VIN LOCK Manufacture Date POWER ACCESS AC 52 IP Mk. 2 Access Controller One-Touch Testing To enter View Mode press the One-Touch button momentarily. To enter Active Mode press and hold the One-Touch button for 2 to 4 seconds. To leave One-Touch testing, press the button momentarily again. Note that One-Touch Active mode will automatically time out after hour. For details of One-Touch modes see the enclosed Quick Start Guide. SIGNAL VOLTAGE DOOR 0.2 A MAX DOOR 2 LOCK 2 DO D LOCK RELAY 30 V; 5A DO D RELAY 2 30 V; 5A SIGA SIGB SIGA SIGB

9 INSP E/BOND TESTED HIP OT BURN F/INPS MAX OUTPUT POWER : MAX INPUT CURRENT : MAINS INPUT VOLTAGE : VAC 47-63Hz FLASHING MAINS ONLY STEADY MAINS & BATTERY DANGER DO T CONNECT TO MAINS SUPPLY UNTIL CORRECTLY INSTAL GLU/LID I OUT N VIN LOCK RX TX RX T X Date Code One-Touch Testing To enter View Mode press the One-Touch button momentarily. To enter Active Mode press and hold the One-Touch button for 2 to 4 seconds. To leave One-Touch testing, press the button momentarily again. Note that One-Touch Active mode will automatically time out after hour. For details of One-Touch modes see the enclosed Quick Start Guide. SEA RECHARGEABLE LEAD-ACID BATTERY SIGNAL VOLTAGE 2/24V 5V DATA 0 I 2 DOOR2 SEA RECHARGEABLE LEAD-ACID BATTERY INSTALLATION CONTROLLER INSTALLATION Perform the following steps to install the PAC 52 Two-Door Controller: SUPS 2 24 OR VOLTS Warning: Use a static strap whenever touching the panel to ensure protection from Electrostatic Discharge (ESD).. Review the panel layout, cable runs, and power needs. OOR 2 Serial No. PAC Part No. MOD LEVEL POWER ACCESS LOCK 2 RELAY 2 2V BATTERY 2V BATTERY OPTIONAL 2V BACKUP X 2V 7aH BATTERY OPTIONAL 24V BACKUP 2x 2V 4.5aH BATTERIES 2. Mount the enclosure at the proper location on the wall. Use appropriate anchors for the mounting material. 3. Run all I/O wires to the enclosure, and properly mark each wire for its use. 4. The power supply should be connected to a grounded 20v AC outlet using the 3 Prong Universal Standard AC Power Cord provided. Caution: Do not apply power at this time. 5. Remove each green terminal connector one at a time to wire the properly labeled cables. See the wiring diagrams. Caution: Do not apply power at this time. 6. If you are using a battery backup function, place the one or two batteries in the enclosure 7. Attach the positive (red) Power Supply-to-Battery cable to the remaining positive (red) battery terminal. 8. Attach the negative (black) Power Supply-to-Battery cable to the remaining negative (black) battery terminal. 9. Apply power to the panel. and run One-Touch Test to check the system Operation. DO T APPLY AC POWER 0

10 INSTALLATION ELOSURE MOUNTING, BACK VIEW Two knock-outs are provided on each of the four sides of the enclosure, these are suitable for 3/4 EMT conduit. Cabinet Electrical Entries Enclosure Knock Outs Top 2 Bottom 2 Right Side 2 Left Side 2

11 INSP E/BOND TESTED HIP OT BURN F/INPS GLU/LID MAX OUTPUT POWER : MAX INPUT CURRENT : MAINS INPUT VOLTAGE : VAC 47-63Hz DANGER DO T CONNECT TO MAINS SUPPLY FLASHING MAINS ONLY UNTIL CORRECTLY STEADY MAINS & BATTERY INSTAL INSTALLATION POWER CONNECTION SUPS 2 24 OR VOLTS The 3A Power Supply is pre-wired in the metal enclosure. Output voltage is jumper-selectable to either 2 (factory setting) or 24V. This power supply can normally provide the controller, readers and lock power. Serial No. PAC Part No. TX RX TX RX IN OUT ADMIN TERM N INPUT: (CONTROLLER + RS-485 N0 NGND CAUTION - FIXED INT See manual for dis OVRD This device complies wi the FCC Rules. Operatio to the following two cond device may not cause h interference, and (2) this accept any interference including interference th undesired operation TCP/IP Made in Manufacture Date AC 52 IP Access Co One-Touch Testing To enter View Mode pre button momentarily. To e press and hold the Onefor 2 to 4 seconds. To le testing, press the button again. Note that One-To will automatically time o For details of One-Touch enclosed Quick Start Gu POWER ACCESS VIN LOCK SIGN 2/24 R MOD LEVEL or 24V Jumper 24V 2V PRE-WIRED FROM POWER SUPPLY 2 OR 24V The power supply includes battery charging at either 2 or 24V. The input indicates the AC Status to the controller, communicating when the power supply has switched from AC to battery. The PAC 52-series controllers draw 2V current. The total amount of current drawn by the controller will depend on the number and type of readers being used. AC POWER The power supply should be connected to a grounded 20v AC outlet using a power cord. A 3-Prong Universal Standard AC Power Cord is provided with the Kit. There are no fuses in the power supply, but it is protected against over current conditions and will cut out if the nominal limit is exceeded and reset once the load is removed. IMANT: To ensure reliable communications and protection from EMI and other transient effects, the controller must be connected to building ground. The power supply will have a ground conductor that leads to building ground through the AC supply. The controller is mounted using the six mounting holes which provide a ground to the enclosure. You should still ensure that the enclosure has a reliable path to building ground. 2

12 SECURITY ON INSTALLATION GS3 MULLION CONNECTION (PAC64 OUTPUT) When using Stanley PAC credentials these readers use a single data line (labeled SIG), using unshielded cable at up to 800ft. The PAC 52 controller can support one or two readers of this type per door. Potted electronics provide protection against inclement weather. Determine an appropriate mounting position on the door frame or wall. SINGLE This is the most common usage. Controller wiring 0.2 A MAX DOOR 2-24V D/SIG /GND D0/CLK SOUND C US LISTED 20 SECURITY ON CTS 52 PRODUCT SPECIFICATIONS (STANLEY PAC CREDENTIALS) Operating Voltage Range Max Current Requirements Max cable distance Cable Requirement Conductors Required 0.5 V to 28 V <00 Ma 800 ft PAC OUTPUT CABLING 22AWG, 6-conductor, stranded, unshielded 4 conductors (If REX and Door Contact not used) SUPS 2 24 OR VOLTS 22AWG 4-conductor stranded, unshielded cable from the controller, up to 800ft to the door. 4 Conductors for Stanley GS3 Mullion Reader TWO S ON A DOOR An optional second reader may be an exit reader or it could be a dual height or disabled entry reader. Locate readers at least 3ft apart to avoid interference. SIMPLE MY SAVING TIPS If you are using a Door Contact and REX, it is possible to use 22AWG 6-Conductor stranded, unshielded cable, if you share the ground wire () at the door. C US LISTED 0.2 A MAX DOOR 2 ON DO SIGA 2-24V D/SIG /GND D0/CLK SOUND Switch Settings for PAC64 Output Format When 3 rd party credentials are enrolled under PAC64 (eg. HID 25Khz Proximity) no change is rquired to the default setup. GS3 Mullion readers should be wired with 4-conductors and the reader type remains Stanley Proximity Reader. HID 346 ProxKey III HID386 ISOProx II Card 3

13 INSTALLATION CONNECTION DETAILS (PAC64 OUTPUT) Installation Notes:. The number of conductors required will depend on whether you are using a door contact and request to exit device. 2. After installation in wet or damp locations, it is good practice to seal the green connector well with electronics grade RTV silicone sealant to ensure that moisture cannot enter or accumulate in wiring compartments. Signal Description Power. The voltage at this terminal is the same as the voltage used to power the controller. Power is limited to 200mA. Controls the on the reader. Makes the go green when a valid card is presented, or flash red-green when access is denied. SIG Data from the reader. If using one reader this goes to Sig A, if using two readers the entry (usually) goes to Sig A, the exit to Sig B. /GND Ground or 0v return. This conductor may also be used for the Door Contact and circuit. TM One Touch Use the 'One Touch' test (See Page 22) to verify correct operation of the readers. Warning: The voltage supplied at the reader power terminals is the same as the controller input voltage (2 or 24V). You should ensure that the readers you are using can operate at this voltage. PROGRAMMING In the Doors section, select the door name. In the Access tab: Select the Reader Type. This should be PAC Proximity Reader Assign an Area to SIG A If using two readers, assign an Area to SIG B 4

14 LOCK CONTROL SUPS 2 24 OR VOLTS TCP/IP This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions: () this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation Made in UK LOCK RELAY 30 V; 5A A + - PRE-WIRED FROM POWER SUPPLY VIN LOCK Manufacture Date POWER ACCESS AC 52 IP Mk. 2 Access Controller One-Touch Testing To enter View Mode press the One-Touch button momentarily. To enter Active Mode press and hold the One-Touch button for 2 to 4 seconds. To leave One-Touch testing, press the button momentarily again. Note that One-Touch Active mode will automatically time out after hour. For details of One-Touch modes see the enclosed Quick Start Guide. SIGNAL VOLTAGE 0.2 A MAX DOOR 2 LOCK 2 RELAY 2 30 V; 5A A + - IMANT! THE MOV (METAL-OXIDE VARISTOR) SUPPLIED WITH EACH SHOULD BE CONNECTED ACROSS THE LOCK TERMINALS. 2/24V 5V DATA 2 DOOR2 DETAILS A A fuse should be connected in line with the positive conductor to each lock. Locks are controlled by a relay. There is one relay, labeled 'LOCK ' or 'LOCK 2', for each door. The relay is able to switch up to 3A at 3. but ensure that the lock current does not exceed the limit of the power supply. Power for the locks can be taken from the Access terminals (LOCK and ) on the controller or from an independent power supply. Voltage at the LOCK terminal is the same as provided at the VIN terminal. Cable gauge should be sufficient to ensure the correct operating voltage is provided at the lock, typically 8AWG. Fail Secure locks (e.g. Strikes) should be switched through the Normally Open () relay terminal. Fail Safe locks (e.g. Magnetic Locks) should be switched through the Normally Closed () relay terminal. It is important to fit the MOV at the lock terminals. One is supplied with each reader. The MOV prevents back EMF (spikes) from damaging the relays or inducing transients in other cables. PROGRAMMING In the Doors section, select the door name. In the Configuration tab: Select Lock Release Time default is 5 seconds In the Details tab: Select a Door Profile if you want automatic opening default is None. AVAILABLE LOCK POWER PRODUCT POWER CONSUMPTION QTY 2V SUB-TOTAL PAC 52 DOOR CONTROLLER STANLEY GS3 MULLION TOTAL@2V 0.42A 3.0A A 2.58A less 20% Safety Factor * 0.52A REMENDED AVAILABLE FOR LOCKS 2A *It is considered best practice to run at less than the full capacity of the power supply. This allows for unforseen peak requirements and will increase lifespan. 5

15 INSTALLATION RS-485 Each Two-Door Starter Kit can be expanded with up to 23 additional Two Door Expansion Kits on a RS-485 multidrop, for a total of 48 Doors. CABLE SPECIFICATIONS Max cable distance CAT5 or CAT6 Up to 3000 ft 22AWG Unshielded Up to 500 ft When used with an RS485 data line, on-board termination resistors can be put in circuit with a simple termination jumper. Ensure that units installed in the middle of the data line have this switch turned OUT. The RS-485 bus must be configured as a straight line with no branches. Termination Jumper Termination: set to IN at each end of the bus set to OUT on devices in between OUT IN OUT IN OUT IN Cat 5 or Cat 6 cable can be used for a total length of up to 3000 feet. Use one twisted pair for the N and N0 signals; use another pair together for NGND. Double over each conductor to make a stronger connection. If shielded cable is used then connect the shield to the ( ) GROUND at one end of the cable only. Note. Only required in harsh environments - Speak to a technical support engineer if required. 6

16 DOOR INPUTS DOOR CONTACT (RMALLY CLOSED DOOR CONTACT) The door contact is usually a sensor in the door frame that detects the position of the door. CABLE SPECIFICATIONS Cable Requirement 22AWG, 2-conductor, stranded, unshielded Door Contact Controller wiring 2-24V D/SIG /GND D0/CLK TAM P SOUND O N CTS A M AX DOOR 2 DO Join wires RMALLY CLOSED The circuit is Normally Closed. When the door is closed the circuit is closed, when the door is open the circuit is open. If the controller knows the door position then it can respond in certain conditions. For example: If the door opens without a valid card or input then a Door Forced alarm is generated. If the door stays open beyond a certain time then a Door Left Open alarm is generated. If the door opens after a valid card or then the lock release time is cancelled after a further 2 seconds. This helps ensure that the door catches again when it closes. Use the 'One Touch' test (Page 22) to verify correct operation. PROGRAMMING In the Doors section, select the door name. In the Configuration tab: Check Door Monitoring default is unchecked Enter Door Open Time this is the time before a Door Left Open Alarm is generated. Typically 30 to 60 seconds (maximum is 255 seconds) 7

17 DOOR INPUTS REQUEST TO (EGRESS, OR REX) CABLE SPECIFICATIONS Cable Requirement 22AWG, 2-conductor, stranded, unshielded The Request to Exit ( or REX) device is located on the secure side of the door. When activated it indicates to the controller that the door is about to open. If the door is being monitored and the controller does not receive the signal, an alarm will be generated. Only one conductor is needed between to controller and the contact if the reader ground is used (as shown in diagram). Alternatively a dedicated pair of conductors can be used. Controller wiring 2-24V D/SIG /GND D0/CLK TAM P SOUND O N CTS A M AX DOOR 2 DO D SIGA SIGB Join wires RMALLY OPEN The circuit is Normally Open. The circuit just needs to close momentarily. It should not remain closed for more than 2 to 3 seconds or more than the lock release time. If the circuit remains closed for more than 5 cycles of the lock release time (25 seconds if the lock release time is 5 seconds) then an Held Down alarm is generated. Activating the device may or may not operate the lock as well this can be set in programming, see below. There are several devices that can be used to generate the signal. Examples include: Push to Exit button a momentary switch near the door that a person presses to release the lock. Crash-bar or Handle switch. A switch inside the crash-bar or lock handle that closes when either is operated. Often used for escape routes where the door has to open when pushed. Motion Rex. A motion detector above the door that detects presence and closes a switch. In most cases this will be set T to operate the lock. These devices can be difficult to set correctly. The detection field should be set so that only people approaching the door activate the switch. You should also ensure that the detector just closes the switch momentarily. Use the 'One Touch' test (see Page 22) to verify correct operation. PROGRAMMING In the Doors section, select the door name. In the Configuration tab: If you do T want the lock to operate when the is closed: Set Mode to No Lock default is Normal 8

18 DOOR OUTPUTS CONTROLLER OVERRIDE AND ER The Door Controller has two extra inputs. Both are normally closed (N/C). RMALLY CLOSED ER The Tamper is prewired to a tamper switch which registers a 'Case Tamper' alarm event when the lid is opened. Pre-Wired Tamper Switch OVERRIDE The Override has a factory installed jumper ensuring its circuit is closed. If you intend to use this input then remove the jumper and connect your own wiring. When this input opens both doors on the controller will unlock. A 'Controller Override' alarm event will be generated. When the input closes the doors will return to their normal operation. If you just want one door to release then use the auxiliary input on the individual door. (see Door Input -> Extra Door Input) RMALLY CLOSED Door Emergency Override 9

19 20 ON CTS DOOR INPUTS EXTRA DOOR INPUT (PER DOOR CHANNEL)* 2-24V D/SIG /GND D0/CLK 52 SOUND 0.2 A MAX DOOR 2 D SIGB RMALLY OPENED DETAILS - INPUT Each door has an extra input. This is normally closed (N/C) or normally open (N/O) depending on function: Reader Tamper N/C Can be used with readers that have a tamper detection circuit. Bolt Door N/O Bolts door no keys operate unless they have an access group with 'Ignore Bolted Doors' privilege. Emergency Override N/O Unlocks door when closed, door returns to normal when opened. Latch Contact N/C Generates a 'Door Lock Forced' alarm when opened EXTRA DOOR OUTPUT (PER DOOR CHANNEL)* DETAILS OUTPUT Each door also has an auxiliary output relay. This can be programmed to respond to a variety of events: Door left open Door Forced Door left open/door forced Alarm shunt Time Profile When door is left open beyond its programmed time When door is opened without a valid key being presented or Either door left open or door forced Opens for lock release time when valid key is presented or pressed Relay follows selected time profile Automatically sound an alarm after a set period of time when a door is propped open. Use the Extra Door Relay and program the system to sound the alarm if a door is held open for too long. PROGRAMMING In the Doors section, select the door name. In the Auxiliary I/O tab: Select Auxiliary Input Mode - default is None Select Auxiliary Output Mode - default is None 20

20 One-Touch Installation Testing The PAC 52-series controller has built-in diagnostics, enabled using the 'One Touch' button. The One Touch button is located next to green 'Status'. This indicates whether One Touch mode is active or not. When One Touch View Mode is enabled the set of small s next to each door channel will operate. If you activate Test Mode then the controller will stop operating and allow all the readers and inputs to be tested. One Touch can be used when the controller is first installed and powered up, and only rquires one person. It requires no programming and can be used to verify that all connections are correctly made and operating as expected. RMAL MODE The status led flashes slowly, about twice a second. The controller works normally as programmed. The indicator lights whenever the lock is released. VIEW MODE Press One Touch for -2 seconds The status led flashes faster, about three times a second. The controller works normally as programmed. The and lights are active. TEST MODE Press One Touch for 4 seconds The status led flashes rapidly, about five times a second. The controller stops working normally and goes into test mode. The and lights are active. DOOR S ( ) Use either mode to observe the door channel s. (See Step 2 on the One-Touch Test Card) If you see the indicator is permanently on, then it is quite possible the circuit is wired as normally closed. If you have a motion installed then you should see this flash on and off when somebody enters the detector field. The indicator will turn red when the door contact is open. TEST MODE The Starter Kit includes a One-Touch Test Card. STEP - TEST MODE INSTALLATION TESTING One Person Installation Testing at the Door. Press the door controller s One Touch button for 4 seconds to activate test mode for one hour. All the readers attached to this controller will latch from red to green. All feedback is provided by the reader. To exit hold 'One Touch' button for 4 seconds or it will time out after hour. Present this card to the Entry Reader. Reader will flash from green to red once and the lock will release. Present this card to the Exit Reader. Reader will flash from green to red twice and the lock will release. Operate the Request-to-Exit (/REX). Reader will flash from green to red three times. Open the Door Contact. Reader will flash from green to red four times. Default state STEP 2 Two Person Installation Testing. INSTALLATION TESTING - TEST MODE STEP INSTALLATION TESTING One Person Installation Testing at the Door. - TEST MODE Press the door controller s One Touch button for 4 seconds to activate test mode for one hour. All the readers attached to this controller will latch from red to green. All feedback is provided by the reader. To exit hold 'One Touch' button for 4 seconds or it will time out after hour. Present this card to the Entry Reader. Reader will flash from green to red once and the lock will release. Present this card to the Exit Reader. Reader will flash from green to red twice and the lock will release. Operate the Request-to-Exit (/REX). Reader will flash from green to red three times. Open the Door Contact. Reader will flash from green to red four times. In Test Mode, the Door Contact () and Request-to-Exit (/REX) lights are active. There are two sets, at the top and bottom of the controller next to Door and Door 2. If the /REX indicator is permanently lit, the /REX circuit may be wired as normally closed. When a motion /REX installed this will flash on and off when somebody enters the detector field. The indicator will turn red when the door contact is open. Default state ESS SIGNAL VOLTAGE 2/24V 5V DATA AY 2 ; 3 A 2 DOOR2 /REX DOOR2 2

21 PAGE INTENTIONALLY BLANK

22 SECURITY ON INSTALLATION ADDENDUM STANLEY GS3 CONNECTION (WIEGAND OUTPUT) When using third-party credentials such as HID with Stanley GS3 readers, it is normal to use the factory default PAC64 output mode and use a single data line (SIGA/D0) using unshielded cable. In some situations, such as a system takeover, you may have existing readers to maintain. In this situation, Stanley GS3 readers can be wired with a wiegand output that uses two data lines (labeled D0 and D) and use shielded cable at up to 500ft. You will need to set the Output Format switch on the GS3 readers to Wiegand (see illustration). The PAC 52 controller can only support one reader of this type per door channel. EXAMPLES OF THIRD PARTY WIEGAND CREDENTIALS PRODUCT SPECIFICATIONS (USING N-PAC CREDENTIALS) Power requirements Operating Voltage Range Max Current Requirements Max cable distance Cable Requirement Conductors Required 0.5 V to 28 V <00 Ma 500 ft HID 346 ProxKey III 22AWG, stranded, shielded HID386 ISOProx II Card 5 conductors (If REX and Door Contact not used) C US C US LISTED ON 2-24V D/SIG /GND D0/CLK SOUND Set the Output Format to Wiegand using the DIP Switches DATA LEVEL There is a jumper on the circuit board that may need to be set for certain types of reader. By default the jumper should be set to 2v/24V. If a reader is powered from a 5V supply, or the reader outputs a 5V signal level, e.g. Bioscrypt fingerprint readers, then set the jumper to 5V 5V 2/24V DATA 23

23 INSTALLATION ADDENDUM CONNECTION DETAILS (WIEGAND OUTPUT) Installation Notes:. The number of conductors will depend on whether you are using a door contact and request to exit device. 3. After installation in wet or damp locations, it is good practice to seal the green connector well with electronics grade RTV silicone sealant to ensure that moisture cannot enter or accumulate in wiring compartments. Signal Description Power. The voltage at this terminal is the same as the voltage used to power the controller. Power is limited to 200mA., VCA D0 Controls the on the reader. Makes the go green when a valid card is presented, or flash red-green when access is denied. Data from the reader. D GND Data from the reader. Ground or 0v return. This conductor may also be used for the Door Contact and circuit. Use the 'One Touch' test (See Page 22) to verify correct operation of the readers. Warning: The voltage supplied at the reader power terminals is the same as the controller input voltage (2 or 24V). You should ensure that the readers you are using can operate at this voltage. PROGRAMMING In the Doors section, select the door name. In the Access tab: Select the Reader Type. This should be Wiegand Assign an Area to SIG A/ SIG B 24

24 Technical Support

ipac Access Controller

ipac Access Controller STANLEY MANUFACTURED ACCESS CONTROL ipac Access Controller INSTALLATION GUIDE CONTENTS INSTALLATION Introduction...3 Installation Procedure...4 ipac Components and Descriptions ipac...5 Enclosures...6

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

STANLEY MANUFACTURED ACCESS CONTROL ACCESS STARTER KIT EASY-TO-USE AND HIGHLY RELIABLE ACCESS CONTROL

STANLEY MANUFACTURED ACCESS CONTROL ACCESS STARTER KIT EASY-TO-USE AND HIGHLY RELIABLE ACCESS CONTROL STANLEY MANUFACTURED ACCESS CONTROL ACCESS STARTER KIT EASY-TO-USE AND HIGHLY RELIABLE ACCESS CONTROL 1 Access Control Starter Kit in-a-box 3 2 5 SIMPLE... EVERYTHING YOU NEED FOR A COMPLETE SYSTEM SCALABLE...

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

Click Save to return to the main Setup screen.

Click Save to return to the main Setup screen. ON-SITE Setup Guide Thank you for purchasing the ON-SITE. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,

More information

SmartLock Controller INSTALLATION MANUAL

SmartLock Controller INSTALLATION MANUAL SmartLock Controller INSTALLATI MANUAL November 2015 Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting...

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information

Quick Start Installation Guide

Quick Start Installation Guide RM-DCM-2 Quick Start Installation Guide Version G0 Document Part Number UM-215 May 2010 OVERVIEW The RM-DCM-2 is a UL294 Listed and UL1076 Listed door control module that includes the RM-4E Reader Module

More information

Cardax FT Controller 3000

Cardax FT Controller 3000 Installation Note Cardax FT Controller 000 CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any

More information

SmartLock Pro INSTALLATION MANUAL

SmartLock Pro INSTALLATION MANUAL SmartLock Pro INSTALLATI MANUAL July 2010 Cutting edge simplicity Table of Contents INTRODUCTI... 3 Diodes... 3 Power Supply Notice... 3 Terminal Strips and Cable... 4 SPECIFICATIS... 5 SMARTLOCK CTROLLER

More information

istar Pro Installation Guide

istar Pro Installation Guide istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general

More information

TruPortal Dual Door Interface Module Quick Reference

TruPortal Dual Door Interface Module Quick Reference TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers

More information

SINGLE READER EXPANSION MODULE

SINGLE READER EXPANSION MODULE SINGLE READER EXPANSION MODULE INSTALLATION GUIDE A D C - A C X 1 TR- SINGLE READER EXPANSION MODULE The ADC-ACX1 Single Reader Expansion Module provides a solution for interfacing to a one Wiegand reader

More information

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1 15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...

More information

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual RD-SR2 Proximity Card Reader with Remote Control User Manual INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control

More information

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

genesis TECHNICAL MANUAL Two-Door Controller GEN-045 Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

Wiring Guide EP.NMINI. Version 1.02 Last Updated: Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass

More information

U-FLASH Setup Guide U-FLASH.

U-FLASH Setup Guide U-FLASH. U-FLASH Setup Guide Thank you for purchasing the U-FLASH. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014 SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions

More information

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers NetGen Hardware Installation Guide for NetGen Ethernet Door Controllers 0613 Table of Contents BLUEWAVE SYSTEM OVERVIEW...2 THE WI-FI LOCK AND SECURITY COMPANY...2 NETGEN DOOR CONTROLLERS...2 INSTALLATION

More information

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work

More information

PXL-250 Tiger Controller

PXL-250 Tiger Controller PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and

More information

EP1501 Intelligent Controller

EP1501 Intelligent Controller J6 BT K K2 TB5 TB 2.35 [59.69] 2.75 [69.85] EP50 Intelligent Controller with Paired Reader Interface for One Physical Barrier Installation and Specifications: www.mercury-security.com 2355 MIRA MAR AVE.

More information

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316 CYPRESS Suprex RF Series Operations Manual Suprex Reader Extender - RF Wireless Interface EXP-2000 SPX-5521 900 Mhz SPX-5521_MAN_0316 Cypress Suprex SPX-5521 Series Overview This manual covers the operation

More information

Expandable Power Systems

Expandable Power Systems Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.

More information

TAC I/NETTM 1284, 1280, Security Control Unit

TAC I/NETTM 1284, 1280, Security Control Unit TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring

More information

Brivo Access Control System (ACS) Installation Manual DOCUMENT NUMBER ENG-DOC-003 ACS5000-E ENG-WI-001

Brivo Access Control System (ACS) Installation Manual DOCUMENT NUMBER ENG-DOC-003 ACS5000-E ENG-WI-001 Brivo Access Control System (ACS) Installation Manual DOCUMENT NUMBER ENG-DOC-003 ENG-WI-001 Legal Disclaimers Federal Communications Commission (FCC) Compliancy This equipment has been tested and found

More information

MR51e Reader Interface

MR51e Reader Interface J4 J TB6 TB5 TB4 TB3 VIN VO TB2 TB J7 2.75 [69.85] 0.2 [5.08] 2.35 [59.69] J3 MR5e Reader Interface Installation and Specifications. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA

More information

Power Hub Cat. No. 83A00-1. Installation Manual WEB VERSION

Power Hub Cat. No. 83A00-1. Installation Manual WEB VERSION Power Hub Cat. No. 83A00-1 Installation Manual WARNINGS AND CAUTIONS Read and understand all instructions. Follow all warnings and instructions marked on the product. Do not use this product near water

More information

Amano Nexus Lite Controller INSTALLATION MANUAL

Amano Nexus Lite Controller INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power NEXUS LITE Amano Nexus Lite Controller INSTALLATION MANUAL MODEL NUMBER: ISC920-0-0-AC-XX ISC921-5-0-AC-XX Designed to work in an indoor (dry)

More information

2000 Series e/em Style Keypad Installation and Programming Manual

2000 Series e/em Style Keypad Installation and Programming Manual 2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6

More information

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated: Wiring Guide EP.L3800 Version 1.03 Last Updated: 13-10-2014 1 Note: L3800 is the serial enabled lift controller. L3800 will ship with a HIO board in a package which can cater up to 8 floors. It can connect

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

ImproX IXP20 Controller INSTALLATION MANUAL

ImproX IXP20 Controller INSTALLATION MANUAL MODEL NUMBER: ISC920-0-0-GB-XX ISC921-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated: Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact

More information

DC Outdoor Power Supply/Chargers

DC Outdoor Power Supply/Chargers DC Outdoor Power Supply/Chargers Installation Guide Models Include: WayPoint3 WayPoint7-2.5A @ 12VDC or 24VDC. - 6A @ 12VDC or 24VDC. - 115/230VAC input. - 115VAC input. WayPoint5 WayPoint7V - 4A @ 12VDC

More information

Access Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64

Access Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64 Essential Essential Plus Elite 36 Elite 64 Access Control System Document Number: 620-100239, Rev. D Installation Guide USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800)

More information

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode -Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add

More information

Suprex RS-485 SPX-7500 Wired Reader-Extender

Suprex RS-485 SPX-7500 Wired Reader-Extender Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778

More information

UniScan. Impro UniScan Controller INSTALLATION MANUAL

UniScan. Impro UniScan Controller INSTALLATION MANUAL MODEL NUMBER: HCM990-0-0-GB-XX UniScan Impro UniScan Controller INSTALLATION MANUAL SPECIFICATIONS Working Environment... The Controller is designed to work in an indoor or protected outdoor environment

More information

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3 INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: June, 2016 Version: 1.3 2 What s in the Box 2 Screws & Anchors 2 Screwdriver 4 Diode CONTENT Contents What s in the Box...2 Optional accessories...4

More information

SETUP GUIDE INSTALLATION HANDBOOK. For Integrators, Installers and Administrators. Everything on how to get Kisi up and running. getkisi.

SETUP GUIDE INSTALLATION HANDBOOK. For Integrators, Installers and Administrators. Everything on how to get Kisi up and running. getkisi. SETUP GUIDE INSTALLATION HANDBOOK For Integrators, Installers and Administrators Everything on how to get Kisi up and running getkisi.com 1 TABLE OF CONTENT 13 14 INSTALLING KISI AS A STAND-ALONE SYSTEM

More information

Installing Sentor. Hardware Installation

Installing Sentor. Hardware Installation Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3

More information

WRI400 WIRELESS READER INTERFACE

WRI400 WIRELESS READER INTERFACE WRI400 WIRELESS READER INTERFACE Technical Services Training for the WRI400 Launched April 2011 March 12 Technical Services Engineering Support 1 Training Overview WRI400 Description Information Installation

More information

GV-AS Controller. Installation Guide

GV-AS Controller. Installation Guide GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.

More information

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount

More information

Installing the DX LCD Display

Installing the DX LCD Display DX LCD Display User s Guide 3-1 Chapter 3 Installing the DX LCD Display Introduction Use the DX LCD Display as either a portable device, or permanently mount it in a panel or on the wall. For panel and

More information

EL-ST100 KEYPAD CONTROLLER

EL-ST100 KEYPAD CONTROLLER WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6

More information

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN

More information

Zodiac FR100 TM INSTALLATION MANUAL

Zodiac FR100 TM INSTALLATION MANUAL Zodiac FR100 TM INSTALLATION MANUAL June 2014 Table of Contents INTRODUCTION... 3 SPECIFICATIONS... 4 Diodes... 5 Terminal Strips and Cable... 5 READER LAYOUT... 6 READER INSTALLATION... 7 Mounting Plate...

More information

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground. NXT x.0 Wiring and Layout Diagrams. NXT-x I/O Module Shielded CAT- Cabling Shielded -Conductor Cabling total cable length 00 feet max (0 m) Brown/Green/Orange w/o Stripe Brown/Green/Orange with Stripe

More information

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz SPX-5000 Series Operations Manual Suprex Reader Extender - RF Wireless Interface SPX-5601 2.4GHz RPT-5651 2.4GHz Repeater SPX-5521 900 Mhz IOX-7621 2.4GHz EXP-2000 SPX-6601 2.4GHz SPX-5000_MAN_082112 This

More information

MS-3000 MicroStar Reader

MS-3000 MicroStar Reader MicroStar Reader The MicroStar Reader The MicroStar Reader is intended for installation on a window mullion or a door frame, on or off metal, in proximity applications where an unobtrusive reader is required.

More information

ACS5000 Panel (A/E/S) Installation Manual

ACS5000 Panel (A/E/S) Installation Manual ACS5000 Panel (A/E/S) Installation Manual Rev 1 ENG-DOC-003 ACS5000 Installation Manual Page 2 Legal Disclaimers Federal Communications Commission (FCC) Compliancy This equipment has been tested and found

More information

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start

More information

7000 Series Thinline LCD Keypads Models 7060/7063/7070/7073

7000 Series Thinline LCD Keypads Models 7060/7063/7070/7073 INSTALLATION SHEET 7000 Series Thinline LCD Keypads Models 7060/7063/7070/7073 Description The DMP Model 7060, 7063, 7070, and 7073 Thinline LCD Keypads offer the same flexible features and functionality

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09 CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.

More information

0DQXIDFWXULQJ $FFHVV &RQWURO VLQFH

0DQXIDFWXULQJ $FFHVV &RQWURO VLQFH cdvigroup.com Copyright (C) 2011 CDVI. All rights reserved. ATRIUM Access Control is protected by copyright law and international treaties. Unauthorized reproduction or distribution of this product, or

More information

Q WIEGAND EXPANSION MODULE

Q WIEGAND EXPANSION MODULE Q WIEGAND EXPANSION MODULE INSTALLATION MANUAL To prevent possible SERIOUS INJURY or DEATH: READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS. The user is strongly recommended to conduct a product

More information

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code: INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA-675-001 Revision 1.0 Date Code: 1-1-2018 Table of Contents Table of Figures... 3 SPECIFICATIONS:... 4 INSTALLATION... 5 General:... 5 Physical Installation

More information

Installation Manual for D244X Series 24-volt Power Supplies

Installation Manual for D244X Series 24-volt Power Supplies Installation Manual for D244X Series 24-volt Power Supplies D2441-B D2441-C D2443-B D2443-C D2445-B D2445-C D2400 Series 1A 24 volts 1A 24 volts 3A 24 volts 3A 24 volts 5A 24 volts 5A 24 volts Dycon Power

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

Brivo ACS6000 (A/E/F/S) Installation Manual

Brivo ACS6000 (A/E/F/S) Installation Manual Brivo ACS6000 (A/E/F/S) Installation Manual 10/17/2016 Brivo ACS6000 Installation Manual Page 2 Legal Disclaimers Federal Communications Commission (FCC) Compliancy You are cautioned that changes or modifications

More information

4900 SERIES PLC INTERLOCK SYSTEM

4900 SERIES PLC INTERLOCK SYSTEM 4900 SERIES PLC INTERLOCK SYSTEM The 4900 series PLC interlock controller is a cost effective method for operating door interlock and mantrap systems of up to 120 doors. The basic system consists of a

More information

ACTpro 1500 Single Door IP Controller

ACTpro 1500 Single Door IP Controller ACTpro 1500 Single Door IP Controller ACTpro 1520 Single Door IP Controller with 12 V DC 2 amp power supply. Operating & Installation Instructions 18-00085 Issue 2 This manual refers to the ACTpro 1500

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

Wiring Guide EP.HIO. Version 1.03 Last Updated:

Wiring Guide EP.HIO. Version 1.03 Last Updated: Wiring Guide EP.HIO Version 1.03 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual Platform1 version 3 support 6 and 10

More information

ORB TM 4-20 ma Input Box Installation & Operation Manual

ORB TM 4-20 ma Input Box Installation & Operation Manual IOM ORB TM 4-20 ma Input Box Installation & Operation Manual ORB TM 4-20 ma Input Box Installation & Operation Manual CONTENTS I. HANDLING & STORAGE... 1 Inspection and Handling Disposal and Recycling

More information

Quick Start Installation Guide

Quick Start Installation Guide istar Pro Quick Start Installation Guide Version B0 Part Number UM-069 January 2005 OVERVIEW This guide defines all of the commonly used connection methods to the istar Pro. It outlines how to wire readers

More information

ACCESS CONTROL SYSTEM

ACCESS CONTROL SYSTEM ACCESS CONTROL SYSTEM System versions Standalone controllers series based on integrated models KZ-400, 500, 600, 700, KZC-300,800, 900 KaDe Lite system based on integrated controllers KZ-1000 KaDe Premium

More information

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

INSTALLATION INSTRUCTIONS Model 930 EntryCheck SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 930 EntryCheck

More information

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries INSTRUCTION MANUAL DIGI-LOCK Keyless Entry System Installation Programming Troubleshooting BASE Industries 45 Pomona Rd. Corona, CA. 9880 Revision F TABLE OF CONTENTS OWNER REGISTRATION CARD INTRODUCTION

More information

emerge Essential Access Control System

emerge Essential Access Control System emerge Essential Access ontrol System Document Number: 620-100239, Rev. Installation Guide Linear LL 1950 amino Vida Roble, Suite 150 arlsbad, A 92008-6517 www.linearcorp.com Notices All rights strictly

More information

Pyramid Series Proximity Readers

Pyramid Series Proximity Readers The Proximity line of OEM Proximity Readers can be used with virtually any manufacturer's access panel because the readers produce industry standard pass-through Wiegand (26-bit or custom formats) or magnetic

More information

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010 Australian Owned, Designed and Manufactured Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products

More information

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502 Suprex Fiber Optic Reader-Extender SPX-7400 SPX-7410 Product Manual Reader-Extender Manual SPX-7400 Series EXP-2000 Suprex_FiberOptic_MAN_170502 Cypress Integration Solutions 30+ Years of Access Control

More information

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed Infinity ACX 700 Access Control Unit The Infinity ACX 700 is a programmable, stand-alone access controller that is a basic building block of the Infinity Security Management System. Each ACX 700 controls

More information

SPX-7400 Series. Operations Manual. Suprex Reader Extender - Fiber Optic Interface. SPX-7400 shown with EXP-2000 SPX-7400_MAN_082112

SPX-7400 Series. Operations Manual. Suprex Reader Extender - Fiber Optic Interface. SPX-7400 shown with EXP-2000 SPX-7400_MAN_082112 SPX-7400 Series Operations Manual Suprex Reader Extender - Fiber Optic Interface SPX-7400 shown with EXP-2000 SPX-7400_MAN_082112 This manual covers the operation and setup of the Cypress Suprex Fiber

More information

Access Control System - Installation Guide

Access Control System - Installation Guide ACS Access Control System - Installation Guide The Remotelock ACS is a cloud based access management system that integrates external door controllers with internal stand-alone Wi-Fi locks for a complete

More information

SPX-7400_SPX-7410_MAN_161028

SPX-7400_SPX-7410_MAN_161028 Suprex Fiber Optic SPX-7400 & SPX-7410 Suprex Reader-Extender Data Sheet SPX-7400 Series EXP-2000 SPX-7400_SPX-7410_MAN_161028 1 Cypress Suprex SPX-7400 & SPX-7410 Overview The Suprex Fiber Optic SPX-7400

More information

KP2000E/EM Series Style Keypad

KP2000E/EM Series Style Keypad 23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact

More information

DESIGN GUIDE FOR INFINITY SYSTEMS

DESIGN GUIDE FOR INFINITY SYSTEMS Doc. 6001564 Rev B DESIGN GUIDE FOR INFINITY SYSTEMS WITH STAND ALONE OR MULTI-LINK LINK FIRMWARE TABLE OF CONTENTS 1. CABINET DIMENSIONS...3 2. WIRE CHART...3 A. CABLING TO THE MAIN PROCESSOR BOARD...

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

CYPRESS   EXP SPX Expansion interface! modules EXP-2000_MAN_0314 CYPRESS EXP-2000 SPX Expansion interface! modules The EXP-2000 provides additional Door/Panel interface points to most SPX products. The EXP-2000 uses a local RS-485 network through an SPX gateway device.

More information

SEC-H-201 Security Controller

SEC-H-201 Security Controller SEC-H-201 Security Controller INSTALLATION INSTRUCTIONS This document covers the mounting and wiring of the WEBs-AX Security Controller. It assumes that you are an engineer, technician, or service person

More information

Easikey 250. User and Installation Guide v1.0 August 09

Easikey 250. User and Installation Guide v1.0 August 09 Easikey 250 User and Installation Guide 17410 v1.0 August 09 Table of Contents Easikey 250...3 Description...6 How to Use Easikey 250...7 Installation...13 Boxed Easikey 250...23 Initial Programming...29

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

ATP1000 Touchpad/Display Installation Instructions

ATP1000 Touchpad/Display Installation Instructions ATP1000 Touchpad/Display Installation Instructions Product summary The ATP1000 lets you control all programming and operation of compatible security systems (see the Specifications section). The large

More information

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications 12 Universal Expander Module. Installation Notes. Revision 1.2 August. 2003. 1 Reporting Reporting with most Contact ID maps will treat the Mini Expander, Exp32 and Exp16 as the same. (With the exception

More information

Connecting a Cisco Input Module

Connecting a Cisco Input Module CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each

More information