DMS 201 FEATURES LOW-COST MANUAL GONIOMETER SYSTEM

Size: px
Start display at page:

Download "DMS 201 FEATURES LOW-COST MANUAL GONIOMETER SYSTEM"

Transcription

1 light measurement DMS 201 LOW-COST MANUAL GONIOMETER SYSTEM Turnkey solution for electrooptical display characterization for quality control, research and development. FEATURES Measurement and evaluation of emissive, transmissive, reflective, and transflective displays. Comprising light-measuring devices (optional photometer and spectro-radiometer), illumination, electrical driving, computer and software. 2 or 3 manual axes for angular positioning and adjustment. Spectrometer for radiometric and photometric analysis (optional). Fast photometer for analysis of temporal luminance variations (flicker evaluation, gray-to-gray transition times, etc.). Evaluation of all photometric and colorimetric characteristics versus angle of inclination, electrical driving, time and temperature. Directional light sources for measurement of reflectance factor and BRDF (optional). Forced-air temperature control of the display under test (optional). DMScontrol software for automated measurement sequences. VIPER software for analysis, evaluation and visualization of measurement data. Software interface for various video test-pattern generators.

2 DMS 201 Standard components and functionality STANDARD COMPONENTS AND FUNCTIONALITY Manual inclination stage for microscope, with scale Manual adjustment of height (z axis), appr. 300 mm stroke Measurement microscope with adjustable spot sizes (depending on sensor system) Table top version The devices under test are rotated manually, no rotary stage Threads for mounting the adapter for HCS chamber and for DUT fixtures OPTIONAL COMPONENTS Fixture for diffuse reflective illumination (DHS and SDR) and cover of heat-cool stage (HCS) Manual inclination stage of reflective illumination (PID, VADIS, Point Source), with scale Integrated transmissive illumination Manual rotary stage with scale OPTIONAL FLOOR STAND VERSION 2

3 Measurements and evaluations DMS 201 MEASUREMENTS AND EVALUATIONS EOC: variation of luminance, contrast and chromaticity with electrical driving for evaluation of EOTF-characteristics (e. g. threshold-, saturation-voltage, gamma). Transients: luminance versus time for e.g. response time evaluation. Reflectance characteristics under diffuse and directional illumination. Area scan (optional): scanning of display surface area for lateral uniformity evaluation. Customer specific measurements defined with DCS scripting sequences. SOFTWARE DMScontrol for definition and management of single measurements (e. g. angular scan, area scan, electro-optical transfer function (EOTF), cross talk, temporal response, etc.) and measurement sequences, for administration, evaluation and graphical representation of the results. VIPER Visual Performance Evaluation provides a range of versatile evaluation functions, graphical representations of results, and data export capabilities. DCS Device Control System for integration of third party electronic devices e.g. video test-pattern generators into the DMScontrol software. 3

4 DMS 201 System components SYSTEM COMPONENTS The following components and accessories are available for the DMS 201, either included in the standard scope of delivery (standard) or as optional components or accessories (optional). See separate brochures for detailed information and specification data. TEMPERATURE CONTROL HCS 3 (optional): air-forced temperature control device, temperature range -40 C to +85 C, with integrated diffuse reflective illumination. HCS 3A (optional): modified version of HCS-3 improved for easier handling, temperature range -45 C to +85 C, adjustable DUT fixture. LIGHT SOURCES AND ILLUMINATION SYSTEMS HEL 4 (optional): light source with halogenic incandescent lamp for DMS and ConoScope. LC 8 (optional): xenon light source for improved light output. SBS 250 (optional): super-bright light source, for e.g. simulation of ambient light. DHS (optional): diffusing hemisphere for evaluation of contrast of reflective displays. PID (optional): collimated beam illumination. VADIS (optional): variable aperture diffuse illumination source for e.g. scattering characterization of surfaces (BRDF), measurement of reflectance factor. PLS (optional): LED point-source PLS (optional): for measurement of reflectance characteristics including BRDF. SDR (optional): integrating sphere for measurement of diffuse reflectance factor, specular component excluded or included (d/8, SCE or SCI). LIGHT MEASURING DEVICES PMT 3 (optional): fast photometer with photomultiplier tube, bandwidth 100 khz, 500 khz, or 2 MHz. PMT 4 (optional): fast photometer, bandwidth 20 khz. CCDSpect-3 (optional): sensitive, high-resolution spectroradiometer with cooled CCD array for accurate measurement of luminance and chromaticity. 4

5 System components DMS 201 DUT DRIVING ASG (optional): Arbitrary Signal Generator with one channel (standard), 4 or 8 analog output channels (optional). Standard and user defined signal waveforms. For passive matrix driving, direct addressing and driving of TFT panels, etc. Power amplifiers are available for different voltage and current ranges. MDI (optional): Module Driving Interface for communication with display modules via serial, parallel or I 2 C interface. Source Meter (optional): programmable current or voltage source with digital multimeter, in particular for current driven display devices like OLEDs. Multiplexer (optional) for use with Source Meter for driving and measurement of displays with multiple segments and matrix displays. DMM (optional): Digital MultiMeter for DMS series for e.g. measurement of ASG driving current, especially with OLED measurements. Multiplexer plug-in board (optional) for driving and measurement of displays with multiple segments and matrix displays. VDU (optional): Video Driving Unit, proprietary compact video pattern generator with various plug-in interface boards (analog RGB, DVI, LVDS etc) integrated into DMS. Soft-VDU (optional): software for installation on PCs with integrated displays (e.g. laptop computers) for emulation of the VDU pattern generator (see above). DCS (optional): Device Control System for scripting and communication with various external devices (DCI), e.g. video pattern generators, module drivers, power supplies, etc. via RS232, GPIB, USB, or TCP/IP. Also used for definition of driving sequences for the Module Driving Interface (MDI). SOFTWARE DMScontrol (standard) for configuration and control of the instrument, definition and management of measurements (single measurements and sequences), administration, evaluation and graphical representation of results. Visual Performance Evaluation (VIPER) (standard) software package for evaluation and representation of measuring results (on and off-line), data exchange with other software (e.g. spreadsheet applications) and report generation (e.g. pdf-documents). Visual Performance Evaluation (VIPER) network version (optional). Report Generator (optional) for user configurable data export from DMScontrol to spreadsheet software. 5

6 DMS 201 Technical data TECHNICAL DATA Axes Range of inclination for microscope Range of inclination for illumination (optional) z stroke (height) 300 mm DUT dimensions Size of measurement table (W x L) 500 mm x 400 mm Photometer PMT 3 Bandwidth Operating temperature Measurement spot diameter High speed analog-to-digital converter 100 khz (standard), optional 500 khz or 2MHz 25 C ±3 C 0.2, 0.5, 1, 3, 8 mm 12 bit AD converter, sampling rate 2 MHz, Spectroradiometer CCDSpect-3 Spectral range Optical bandwidth (full maximum) Wavelength resolution at data output Luminance measurement CIE illuminant total exposure time of 300 s (averaging over 10 wavelength scans) 380 to 800 nm < 2 nm 1 nm 8 mm: cd/m 2 3 mm: cd/m 2 1 mm: cd/m mm: cd/m 2 Dimensions Size (table top version) (LxWxH) Height of measurement table (table-top version) Height of measurement table (with floor stand) Electronics rack (if available) 790 mm x 500 mm x 580 mm 140 mm 800 mm 750 x 600 x 700 mm Mass Mechanism (incl. microscope) Electronics rack 35 kg 50 kg Facility requirements Mains voltage 230 V, 1 phase (others on request ) Frequency 50 / 60 Hz Ambient operating conditions Ambient temperature Humidity All sizes and masses approximate values. 23 C ±5 C 40 60% rel. humidity 6

7 Product structure DMS 201 PRODUCT STRUCTURE Basic device Optional components (mounted at basic device, removable) Optional components (separate) DMS 201 base mechanism microscope measurement table std tube x additnl. measurement spot adpaters PMT 3 PMT 4 CCDSpect PID electronics components PMC + ADC PA chassis BU6, BU36 arm for illumination ( ) VADIS LED pointsource GRU rack with fan and rollers ASG-1/2/4/8 (MDI) PA-3/30 PA-3/60 optional components for basic device fixture for DHS DHS A DHS-HC A SDR HCS 3 TC XStream light sources HEL 4 (o.ä.) LC 8 SBS 250 transm. illumination diffuser box, light fibre measmnt. table, trsm. + diffuser plate manual rotary stage base frame

8 DMS 201 Order information ORDER INFORMATION Please notice that order information is in process. For further details, please contact Instrument Systems. pcs. Description Part No. also required Basic system DMS 201 basic system with microscope Accessories measurement table, standard Inclination arm for reflective light source thread mount (for DHS, HCS, SDR) transmissive illumination (incl. measm. table, light HEL 4 or LC8 or SBS 250 fibre, diffuser chamber and plate) manual rotary table floor stand Microscope accessories microscope tube x pinhole adapter 0.2 mm pinhole adapter 0.5 mm pinhole adapter 1 mm pinhole adapter 3 mm reduction tube 1 mm reduction tube 3 mm reduction tube 8 mm Sensor systems PMT 3/100 photometric detector (100 khz BW) GRU, or PMC/Daq unit PMT 3/500 photometric detector (500 khz BW) GRU or PMC/Daq unit PMT 3/2M photometric detector (2 MHz BW) GRU or PMC/Daq unit PMT 4 (20 khz) B GRU or PMC/Daq unit GRU modules PMC 4 and ADC A GRU B PMC/Daq unit: PMC 4 serial and Daq board in case CCDSpect-3 spectroradiometer Light sources PID parallel illumination arm for refl. light sources, VADIS 800 diffuse variable aperture illumination arm for refl. light sources, LED pointsource arm for refl. light sources, DHS diffuse-reflective illumination A , HEL 4 or LC 8 or SBS 250 DHS-HC diffuse-reflective illumination (HCS A , HEL 4 or LC 8 or SBS 250 geometry) SDR , HEL 4 or LC 8 or SBS 250 HEL 4 halogenic light source LC 8 Xenon light source SBS 250 super-bright source (on request) Temperature control HCS 3 (incl. chamber and air thermostat) thread mount TC Driving electronics GRU - see separate brochure --- MDI 2 - see separate GRU brochure --- DCI/MDI software extension VDU 2 - see separate brochure --- SourceMeter package (incl. switching unit) --- multiplexer board Software extensions DCS Device Control System (DCI + MDI) Document BR025.2, November All specifications are subject to change without prior notice. 8 light measurement Instrument Systems GmbH Neumarkter Str Munich, Germany Tel.: / Fax: / info@instrumentsystems.com

DMS 903 FEATURES GONIOMETER SYSTEM FOR COMPLETE DISPLAY CHARACTERIZATION

DMS 903 FEATURES GONIOMETER SYSTEM FOR COMPLETE DISPLAY CHARACTERIZATION light measurement DMS 903 GONIOMETER SYSTEM FOR COMPLETE DISPLAY CHARACTERIZATION Turnkey solution with motorized scanning for detailed electrooptical display characterization of large-area displays for

More information

DMS 803 FEATURES OPTIONS GONIOMETER SYSTEM FOR COMPLETE DISPLAY CHARACTERIZATION

DMS 803 FEATURES OPTIONS GONIOMETER SYSTEM FOR COMPLETE DISPLAY CHARACTERIZATION GONIOMETER SYSTEM FOR COMPLETE DISPLAY CHARACTERIZATION Turnkey solution with motorized scanning for detailed electro-optical display characterization for quality control, research and development. FEATURES

More information

Reflective Illumination for DMS 803 / 505

Reflective Illumination for DMS 803 / 505 APPLICATION NOTE // Dr. Michael E. Becker Reflective Illumination for DMS 803 / 505 DHS, SDR, VADIS, PID & PLS The instruments of the DMS 803 / 505 series are precision goniometers for directional scanning

More information

We bring quality to light. LGS 350 Goniophotometer

We bring quality to light. LGS 350 Goniophotometer We bring quality to light. LGS 350 Goniophotometer light measurement The features at a glance Type C goniophotometer with horizontal optical axis For samples up to max. 700 mm diameter and 8 kg weight

More information

Features. Brightness Contrast Color Uniformity Cross-talk Color Gamut Reflection

Features. Brightness Contrast Color Uniformity Cross-talk Color Gamut Reflection FPM-505R Reflective isplay Measurement ystem Ideal for optical performance assessment of reflective, transflective, emissive, and transmissive displays Overview The FPM-505R Reflective isplay Measurement

More information

Light Tec Scattering measurements guideline

Light Tec Scattering measurements guideline Light Tec Scattering measurements guideline 1 Our Laboratory Light Tec is equipped with a Photometric Laboratory (a dark room) including: Goniophotometers: REFLET 180S. High specular bench (10 meters),

More information

Light Tec Scattering measurements guideline

Light Tec Scattering measurements guideline Light Tec Scattering measurements guideline 1 2 Light Tec Locations REFLET assembling plant, Aix-en-Provence, France Light Tec GmbH, Munich, Germany German office Light Tec Sarl, Hyères, France Main office

More information

Light Tec Scattering measurements guideline

Light Tec Scattering measurements guideline Light Tec Scattering measurements guideline 1 Our Laboratory Light Tec is equipped with a Photometric Laboratory (a dark room) including: Goniophotometers: REFLET 180S. High specular bench (10 meters),

More information

Instruction manual for operating the Goniospectrometer in SSL Characterization

Instruction manual for operating the Goniospectrometer in SSL Characterization Aalto University School of Electrical Engineering Metrology Research Institute Janne Askola Instruction manual for operating Version 1.0 16/08/2016 Page 2 (7) Table of contents 1. Definition... 3 1.1.

More information

Mu lt i s p e c t r a l

Mu lt i s p e c t r a l Viewing Angle Analyser Revolutionary system for full spectral and polarization measurement in the entire viewing angle EZContrastMS80 & EZContrastMS88 ADVANCED LIGHT ANALYSIS by Field iris Fourier plane

More information

Light Tec Scattering measurements guideline

Light Tec Scattering measurements guideline Light Tec Scattering measurements guideline 1 Our Laboratory Light Tec is equipped with a Photometric Laboratory (a dark room) including: Goniophotometers: REFLET180s. High specular bench (10 meters),

More information

Leica TCS SPE. Spectacular Imaging! Technical Documentation

Leica TCS SPE. Spectacular Imaging! Technical Documentation Leica TCS SPE Spectacular Imaging! Technical Documentation Leica TCS SPE Spectacular Imaging Easy to Achieve A Reliable System Affordable Excellence The high resolution spectral confocal Leica TCS SPE

More information

We Bring Light into the Dark. Reliable Differentiation also of Dark Colors.

We Bring Light into the Dark. Reliable Differentiation also of Dark Colors. We Bring Light into the Dark. Reliable Differentiation also of Dark Colors. Color Control and Color Measurement SPECTRO-3-CL / -JR / -ANA Series True Color Sensors SPECTRO-3-CL Series / SPECTRO-3-JR Series

More information

FluxGage. FluxGage. LED Luminaire Measurement System User Manual

FluxGage. FluxGage. LED Luminaire Measurement System User Manual FluxGage FluxGage LED Luminaire Measurement System User Manual 1 Acronyms... 3 2 Introduction... 4 2.1 Operation principle... 4 3 Specifications... 5 4 Mechanical and Electrical Installation... 9 4.1 Unpacking...

More information

ISP Series. Integrating spheres for all applications. We bring quality to light.

ISP Series. Integrating spheres for all applications. We bring quality to light. ISP Series Integrating spheres for all applications We bring quality to light. 01 \\ Integrating spheres for all applications Instrument Systems developed a complete family of integrating spheres in the

More information

Imaging Sphere Measurement of Luminous Intensity, View Angle, and Scatter Distribution Functions

Imaging Sphere Measurement of Luminous Intensity, View Angle, and Scatter Distribution Functions Imaging Sphere Measurement of Luminous Intensity, View Angle, and Scatter Distribution Functions Hubert Kostal, Vice President of Sales and Marketing Radiant Imaging, Inc. 22908 NE Alder Crest Drive, Suite

More information

SOLAR LIGHTLINE SERIES

SOLAR LIGHTLINE SERIES Features Meets Class AAA ASTM standards Fiberized output for flexible illumination. Easy-to-use touchscreen controls Light intensity control is available Remote control by PC Cost-effective for researchers

More information

Scattering measurements. Guidelines for measurements service

Scattering measurements. Guidelines for measurements service Scattering measurements Guidelines for measurements service 1 Content Introduction Light Tec Presentation Instruments availalable. Scattering measurements Refelctors Diffusers Colors issuses Volume Scattering

More information

Dr. Larry J. Paxton Johns Hopkins University Applied Physics Laboratory Laurel, MD (301) (301) fax

Dr. Larry J. Paxton Johns Hopkins University Applied Physics Laboratory Laurel, MD (301) (301) fax Dr. Larry J. Paxton Johns Hopkins University Applied Physics Laboratory Laurel, MD 20723 (301) 953-6871 (301) 953-6670 fax Understand the instrument. Be able to convert measured counts/pixel on-orbit into

More information

APPLICATION NOTE. New approach for directional analysis of scattered light

APPLICATION NOTE. New approach for directional analysis of scattered light APPLICATION NOTE \\ Dr. Martin Wolf, Dr. Michael E. Becker New approach for directional analysis of scattered light This application note describes how the bidirectional scattering distribution function

More information

Specification Sheet FPI lab

Specification Sheet FPI lab Specification Sheet FPI lab Off-line Process Control Max. Sample Size 500 mm x 500 mm High Resolution Local Defect Detection and Coating Thickness Measurement Professional Process Perfection dr.schwab

More information

Wat is licht, wat is meten? Belgisch Perspectief! Spectraal of niet-spectraal meten: that s the question

Wat is licht, wat is meten? Belgisch Perspectief! Spectraal of niet-spectraal meten: that s the question Wat is licht, wat is meten? Belgisch Perspectief! Spectraal of niet-spectraal meten: that s the question IGOV kenniscafé Arnhem, 31 oktober 2013 Peter Hanselaer Light&Lighting Laboratory Introduction Spectral

More information

specification asteria light meter

specification asteria light meter specification asteria light meter Contents 1 Asteria: luminance / illuminance & flicker measurement device... 3 2 Highlights... 3 3 Asteria general specifications... 4 4 Typical spectral sensitivity of

More information

TriAngle. Electronic Autocollimators for Precise Angle Measurement

TriAngle. Electronic Autocollimators for Precise Angle Measurement TriAngle Electronic Autocollimators for Precise Angle Measurement Angle Measurement Solutions Contents Page TriAngle Angle Measurement Solutions 3 Operating Principle 4 TriAngle Product Range 5 Highly

More information

Adaptable Full-Color LED DMX Luminaire

Adaptable Full-Color LED DMX Luminaire TRIUMPH TR30 Adaptable Full-Color LED DMX Luminaire The Luxium TM TR30 is a unique LED lighting fixture with a DMX control system that merges an innovative high-output lighting module using 12 multi-color

More information

Laser welding. New in the range Laser devices Accessories. Laser welding fillers

Laser welding. New in the range Laser devices Accessories. Laser welding fillers Laser welding New in the range Laser devices Accessories Laser welding fillers 5 5. Welding and coating systems // 5.1. Welding units and accessories High-precision laser welding system D-Open Extremely

More information

Metis H309 / H316 / H318

Metis H309 / H316 / H318 Metis H309 / H316 / H318 High-Speed 1-Color Radiation Pyrometers High-Speed pyrometers for non-contact temperature measurement in short wavelength spectral range, primarily for measurements on metals and

More information

Metis M313. Narrow-Band High-End 1-Color Radiation Pyrometer

Metis M313. Narrow-Band High-End 1-Color Radiation Pyrometer Metis M313 Narrow-Band High-End 1-Color Radiation Pyrometer Pyrometer for non-contact temperature measurement in short-wave and narrow-band spectral range for special applications. Wavelength matched to

More information

m e a s u r e m e n t

m e a s u r e m e n t Viewing Co n e m e a s u r e m e n t The world leader for Fourier optics viewing angle instruments For Luminance, Chromaticity, Radiance & Polarization EZLite, EZContrastL80, EZContrastL80W, EZContrastXL88

More information

Council for Optical Radiation Measurements (CORM) 2016 Annual Technical Conference May 15 18, 2016, Gaithersburg, MD

Council for Optical Radiation Measurements (CORM) 2016 Annual Technical Conference May 15 18, 2016, Gaithersburg, MD Council for Optical Radiation Measurements (CORM) 2016 Annual Technical Conference May 15 18, 2016, Gaithersburg, MD Multispectral measurements of emissive and reflective properties of displays: Application

More information

15-06 Morlot Avenue, Fair Lawn, NJ USA Tel: (201) Fax: (201) LED SERIES DMX TUBE LED RGB DMX TUBE

15-06 Morlot Avenue, Fair Lawn, NJ USA Tel: (201) Fax: (201) LED SERIES DMX TUBE LED RGB DMX TUBE 15-06 Morlot Avenue, Fair Lawn, NJ 07410 USA Tel: (201) 796-2690 Fax: (201) 796-8818 info@articulight.com articulight@aol.com LED SERIES www.articulight.com DMX TUBE LED RGB DMX TUBE COLOR * TEXT * GRAPHICS

More information

LIMO Line Laser System - PEX High Power Diode Laser System for Industrial Applications

LIMO Line Laser System - PEX High Power Diode Laser System for Industrial Applications General Description: Flat Panel Display The laser system is engineered to generate a homogeneous line of 80 mm x 0.2 mm. Componets: - 9x Laser modules - 9x Fibres - Beam Shaping Module - High power laser

More information

TFT-LCD Technology Introduction

TFT-LCD Technology Introduction TFT-LCD Technology Introduction Thin film transistor liquid crystal display (TFT-LCD) is a flat panel display one of the most important fields, because of its many advantages, is the only display technology

More information

Model S471 Portable Optometer

Model S471 Portable Optometer Model S471 Portable Optometer With over 50 years of experience in developing light measurement instruments, Gamma Scientific is trusted by the world s leading organizations to provide accurate results.

More information

Light Tec. Characterization of ultra-polished surfaces in UV and IR. ICSO October 2016 Biarritz, France

Light Tec. Characterization of ultra-polished surfaces in UV and IR. ICSO October 2016 Biarritz, France ICSO 2016 17-21 October 2016 Biarritz, France Light Tec Characterization of ultra-polished surfaces in UV and IR Quentin Kuperman, Author, Technical Manager Yan Cornil, Presenter, CEO Workshop 2016, 12/09

More information

LED-Illumination with Control Unit Ident.-No

LED-Illumination with Control Unit Ident.-No A HAAG-STREIT COMPANY MÖLLER-WEDEL OPTICAL GmbH, Rosengarten 10, D-22880 Wedel with Control Unit Ident.-No. 773 190 01 Valid from Hardware / Software Rev. / SN 1.0 IDENT.-NO. 217 321 09 Document Version

More information

Metis M309 / M316 / M318

Metis M309 / M316 / M318 Metis M309 / M316 / M318 High-End 1-Color Radiation Pyrometers Pyrometers for non-contact temperature measurement in short wavelength spectral range, primarily for measurements on metals and bright and

More information

OP-C16 VERSATILITY FOR ALL TECHNIQUES. The OP-C16 microscope manufactured by OPTOMIC fulfils the most demanding requirements.

OP-C16 VERSATILITY FOR ALL TECHNIQUES. The OP-C16 microscope manufactured by OPTOMIC fulfils the most demanding requirements. microscope OP-C16 OP-C16 The OP-C16 microscope manufactured by OPTOMIC fulfils the most demanding requirements. The OP-C16 microscope offers one of the widest ranges of lighting systems and beam splitters,

More information

Prizmatix. Optical Specifications. Mic-LED-635 spectrum. BLCC-02 Benchtop LED Current Controller Specifications

Prizmatix. Optical Specifications. Mic-LED-635 spectrum. BLCC-02 Benchtop LED Current Controller Specifications Mic-LED-635 High Power Collimated Red LED Light Source for Fluorescence Microscopy Featuring Prizmatix Modular Design for Multi-Wavelength and Fiberoptic Setup Ver. 01 Introduction The compact Mic-LED-635,

More information

PRODUCT INFORMATION Model 1000XP Wide Range Particle Spectrometer (WPS )

PRODUCT INFORMATION Model 1000XP Wide Range Particle Spectrometer (WPS ) PRODUCT INFORMATION Model 1000XP Wide Range Particle Spectrometer (WPS ) With the lower size limit extended from 10nm to 5 nm, the WPS can now count and size aerosol particles automatically from 5nm to

More information

ULS300 Variable Radiance Uniform Light Source

ULS300 Variable Radiance Uniform Light Source . Variable Radiance Uniform Light Source www.bentham.co.uk Achieving high quality images with sensors and cameras requires accurate uniformity analysis at the pixel level, particularly where wideangle

More information

C x Hexapod Motion Controller

C x Hexapod Motion Controller C-887.52x Hexapod Motion Controller Compact Bench-Top Device for Controlling 6-Axis Systems Sophisticated controller using vector algorithms Commanding in Cartesian coordinates Changes of the reference

More information

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system Specifications & more > > System Specifications > > Consumables > > Accessories System Overview Cat. No. 16300 Analyzer type 4 plate fully automated ELISA analyzer Reagent system Open (Human tests predefined)

More information

New capabilities of diffuser calibration lab at GSFC NASA to support remote sensing instrumentation

New capabilities of diffuser calibration lab at GSFC NASA to support remote sensing instrumentation New capabilities of diffuser calibration lab at GSFC NASA to support remote sensing instrumentation Jinan Zeng1, Jim Butler2, and Jack Xiong2 1Fibertek Incorporation, 13605 Dulles Technology Dr., Herndon,

More information

Leica TCS SPE. Spectacular Imaging! Technical Documentation

Leica TCS SPE. Spectacular Imaging! Technical Documentation Leica TCS SPE Spectacular Imaging! Technical Documentation Leica TCS SPE Spectacular Imaging Easy to Achieve Built-in Reliability Affordable Excellence The new high resolution spectral confocal Leica TCS

More information

Sepacore X10 / X50 system Technical data sheet

Sepacore X10 / X50 system Technical data sheet Sepacore X10 / X50 system Technical data sheet Sepacore X10 and X50 flash chromatography systems address most requirements for the purification of organic compounds. Whether a crude synthesis mixture or

More information

Measuring range X / Y mm 100 / / /170 Z travel mm 200 / 400** Max. table load kg 20

Measuring range X / Y mm 100 / / /170 Z travel mm 200 / 400** Max. table load kg 20 - 10 MarVision. Optical Measuring Instruments Workshop Measuring Microscope MarVision MM 220 Applications For measuring distances (QC 100); bore holes and angles and determination of geometric elements

More information

Technical Specifications for High speed PIV and High speed PIV-PLIF system

Technical Specifications for High speed PIV and High speed PIV-PLIF system Technical Specifications for High speed PIV and High speed PIV-PLIF system MODULE A. HIGH SPEED PIV (3-C) A1. Double Cavity High Speed Laser (up to 10 khz): The vendor should provide Dual Head (DH) laser

More information

Data Sheet. OCR Reader CR 700. vision technology

Data Sheet. OCR Reader CR 700. vision technology Data Sheet OCR Reader CR 700 vision technology OCR Reader CR 700 The readers of the CR 700 series are ultra-compact, Ethernet-ready reading systems for fast and secure detection of optical characters (OCR),

More information

Reprint (R30) Accurate Chromaticity Measurements of Lighting Components. Reprinted with permission from Craig J. Coley The Communications Repair depot

Reprint (R30) Accurate Chromaticity Measurements of Lighting Components. Reprinted with permission from Craig J. Coley The Communications Repair depot Reprint (R30) Accurate Chromaticity Measurements of Lighting Components Reprinted with permission from Craig J. Coley The Communications Repair depot June 2006 Gooch & Housego 4632 36 th Street, Orlando,

More information

microscope OP-Dent-5

microscope OP-Dent-5 microscope OP-Dent-5 OP-Dent-5 The OP-Dent-5 microscope manufactured by OP- TOMIC fulfils the most demanding requirements in the dental field. The OP-Dent-5 microscope offers one of the widest ranges of

More information

A U T O C O L L I M A T O R S

A U T O C O L L I M A T O R S Printed in Germany 229 900 E 04/07 E l e c t r o n i c α A U T O C O L L I M A T O R S Measure With Precision MÖLLER-WEDEL OPTICAL GmbH Rosengarten 10 D-22880 Wedel Tel : +49-41 03-9 37 76 10 Fax: +49-41

More information

NEAR FIELD GONIOMETRIC SYSTEMS FOR SOLID STATE LIGHTING: LUMINANCE, INTENSITY, COLOR, AND

NEAR FIELD GONIOMETRIC SYSTEMS FOR SOLID STATE LIGHTING: LUMINANCE, INTENSITY, COLOR, AND NEAR FIELD GONIOMETRIC SYSTEMS FOR SOLID STATE LIGHTING: LUMINANCE, INTENSITY, COLOR, AND SPECTRA AS A FUNCTION OF ANGLE Douglas Kreysar Chief Operating Officer Presentation Outline What is a Near Field

More information

Data Sheet. Code Reader BR 650 and CR 750 with remote sensor head. vision technology

Data Sheet. Code Reader BR 650 and CR 750 with remote sensor head. vision technology Data Sheet Code Reader BR 650 and CR 750 with remote sensor head vision technology Technical Data model BR 650 CR 750 reading distance field of view (FOV) depth of focus max. transportation speed sensor

More information

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced three phase relay test set The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:

More information

X=2000 Z=2000 X=2000 Z=1600. E0/E150 in µm L/ L/ L/ L/ L/ L/400. R0 in µm

X=2000 Z=2000 X=2000 Z=1600. E0/E150 in µm L/ L/ L/ L/ L/ L/400. R0 in µm ZEISS MMZ M Specifications Version: November 2017 System description Type according to ISO 10360-1:2000 Moving bridge CMM Operating mode motorized / CNC Sensor mounts Fixed installation of ZEISS VAST gold

More information

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System Advanced Protection Relay Test Set and Measurement System Multi-tasking equipment designed for testing protection relays, energy meters, transducers Particularly designed to test RTU (remote terminal unit)

More information

Axes 150 mm/s 150 mm/s. Y axis Z axis Vector 260 mm/s 260 mm/s. P in µm P in µm

Axes 150 mm/s 150 mm/s. Y axis Z axis Vector 260 mm/s 260 mm/s. P in µm P in µm ZEISS PRO / Specifications Version: May 2016 System description ZEISS PRO Models Operating mode Sensor mounts Software Horizontal-arm measuring machine on X-axis guide for flush-floor installation Horizontal-arm

More information

Filter Fan Unit LIGHT

Filter Fan Unit LIGHT Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual

More information

More Precision. thermoimager TIM // Compact thermal imaging cameras

More Precision. thermoimager TIM // Compact thermal imaging cameras More Precision thermoimager TIM // Compact thermal imaging cameras 10 Smallest VGA infrared camera in the world thermoimager TIM 640 thermoimager TIM 640 Miniature infrared camera with VGA resolutions

More information

LIFA. SPECIFICATIONs. Fluorescence Lifetime Attachment LIFA14001A02 25/02/2014

LIFA. SPECIFICATIONs. Fluorescence Lifetime Attachment LIFA14001A02 25/02/2014 LIFA Fluorescence Lifetime Attachment The LIFA is a dedicated system for Fluorescence Lifetime Imaging Microscopy (FLIM). It allows the generation of lifetime images on any widefield fluorescence microscope

More information

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air

More information

The new Photonic F1 LED light source has set a further milestone in the development of modern cold light sources.

The new Photonic F1 LED light source has set a further milestone in the development of modern cold light sources. LED LIGHT SOURCE F1 The new Photonic F1 LED light source has set a further milestone in the development of modern cold light sources. This light source combines LED illumination with the possibilities

More information

Microscope. Dual Magnification Microscope 20X / 40X. Base: 115 x 180mm Net weight: 4.0kg. Stereo Zoom Microscope 7X to 45X

Microscope. Dual Magnification Microscope 20X / 40X. Base: 115 x 180mm Net weight: 4.0kg. Stereo Zoom Microscope 7X to 45X Dual Magnification Microscope XTJ6000-B1 Magnification: 10X/20X, 10X/30X, 20X/40X Objective: 1X/2X, 1X/3X, 2X/4X Working distance: XTJ6012: 110mm, XTJ6013: 102mm, XTJ6024: 90mm Illuminator: 8W fluorescent

More information

More Precision. optocontrol // Optical precision micrometers

More Precision. optocontrol // Optical precision micrometers More Precision optocontrol // Optical precision micrometers 4 Compact laser micrometers with high measuring rate optocontrol 1200 / 1201 Measuring range 2-30mm Resolution 10µm Measuring rate up to 100kHz

More information

Imaging System, Laparoscopy Insufflator & Trolley

Imaging System, Laparoscopy Insufflator & Trolley Imaging System, Laparoscopy Insufflator & Trolley Page 1/11 MEDICAL TFT-LCD MONITOR 19 Item-No.: 92-992-119 Page 2/11 Medical TFT-LCD Monitor 19 Active screen size Active area 19.0 inches (481,84 mm) diagonal

More information

Operating Instructions OEM Spectrometer RU 60

Operating Instructions OEM Spectrometer RU 60 OEM Spectrometer RU 60 JETI Technische Instrumente GmbH Tatzendpromenade 2 D-07745 Jena Tel. +49-3641-225 680 Fax. +49-3641-225 681 E-mail: sales@jeti.com Internet: www.jeti.com Table of contents 1. Features

More information

DPS SERIES DC POWER SUPPLIES

DPS SERIES DC POWER SUPPLIES DPS SERIES: 15kW - 60kW Key features: 15kW to 60kW Models Higher Power Configurations Available 3U Compact Form Factor Voltage Ranges up to 1200 Vdc Current Ranges up to 3000 Adc High-Speed Precision Metering

More information

Dual Fiber SWIR Laser Doppler Vibrometer

Dual Fiber SWIR Laser Doppler Vibrometer Dual Fiber SWIR Laser Doppler Vibrometer The OptoMET Dual Fiber SWIR Vibrometer consists of a SWIR vibrometer and a flexible Dual-Fiber head, different objective lenses either collimated or focused are

More information

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions SCHOTT FLM 4 Fiber Lighting Modul Operating Instructions Contents 1. Important information 3 2. Scope of Delivery 3 3. Intended use 3 4. Safety information 4 5. Operation 5 5.1. LED Optics Module 5 5.2.

More information

Spectrograph overview:

Spectrograph overview: High performance measurement systems Monochromator Family Gilden Photonics offers a range of integrated optical wavelength solutions in customized designs, OEM design, manufacturing and value added resell

More information

Metis M309 / M316 / M318

Metis M309 / M316 / M318 Metis M309 / M316 / M318 1-Color Radiation Pyrometers Pyrometers for non-contact temperature measurement in short wavelength spectral range, primarily for measurements on metals and bright and shiny materials,

More information

LED19WPAR38/NFL/827-DIM

LED19WPAR38/NFL/827-DIM LED19WPAR38/NFL/827-DIM EiKO Global, LLC Model: LED19WPAR38/NFL/827-DIM TABLE OF CONTENTS 1 - GENERAL INFORMATION... 3 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)... 3 1.2 OBJECTIVE... 3 1.3

More information

Data Acquisition Package

Data Acquisition Package 6.0 5.0 4.0 3.0 2.0 1.0 0.0 1000 0.0 1500 500 2000 2500 3000 Data Acquisition Package The increased use and availabillity in the schools made it natural to adopt our Electrical Machine System to this environment.

More information

Sample Sizes: up to 1 X1 X 1/4. Scanners: 50 X 50 X 17 microns and 15 X 15 X 7 microns

Sample Sizes: up to 1 X1 X 1/4. Scanners: 50 X 50 X 17 microns and 15 X 15 X 7 microns R-AFM100 For Nanotechnology Researchers Wanting to do routine scanning of nano-structures Instrument Innovators Using AFM as a platform to create a new instrument Educators Teaching students about AFM

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

POSITIONING DEVICES AND ACCESSORIES FOR ANECHOIC CHAMBERS, OATS AND SHIELDED ROOMS

POSITIONING DEVICES AND ACCESSORIES FOR ANECHOIC CHAMBERS, OATS AND SHIELDED ROOMS Antenna masts, Turntables, Controllers, Shielded video systems, Shielded audio systems and Optic converters POSITIONING DEVICES AND ACCESSORIES FOR ANECHOIC CHAMBERS, OATS AND SHIELDED ROOMS FAM - FULLY

More information

WHITE PAPER. Application of Imaging Sphere for BSDF Measurements of Arbitrary Materials

WHITE PAPER. Application of Imaging Sphere for BSDF Measurements of Arbitrary Materials Application of Imaging Sphere for BSDF Measurements of Arbitrary Materials Application of Imaging Sphere for BSDF Measurements of Arbitrary Materials Abstract BSDF measurements are broadly applicable to

More information

Vision Illumination. Vision Illumination. LED ring lights. BrightLight LED coaxial illuminators. Fiber optic illuminators. Power supplies.

Vision Illumination. Vision Illumination. LED ring lights. BrightLight LED coaxial illuminators. Fiber optic illuminators. Power supplies. LED ring lights. BrightLight LED coaxial illuminators. Fiber optic illuminators. Power supplies. Illumination LED-Based Benefits of Navitar LED-Based Illumination All of our LED systems provide a number

More information

SYNCERITY TM 1024 x 256

SYNCERITY TM 1024 x 256 ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING SYNCERITY TM 1024 x 256 Open-Electrode TE-Cooled CCD

More information

300W 1.5kW, QUBE Fiber Lasers

300W 1.5kW, QUBE Fiber Lasers Technical Specification 300W 1.5kW, QUBE Fiber Lasers CONTENTS 1.1 SCOPE 2 1.2 OPTICAL SPECIFICATION 2 1.3 BEAM DELIVERY FIBER SPECIFICATION 3 1.4 ALIGNMENT LASER 3 1.5 POWER DISTRIBUTION 3 1.6 WATER COOLING

More information

MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION

MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION MODEL 102P 102R DESCRIPTION Floor Stand (Plane) Floor Stand (Modified) HTRB Burn-In System (diode) Component Burn-In

More information

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

More Precision. optoncdt // Laser displacement sensors (triangulation)

More Precision. optoncdt // Laser displacement sensors (triangulation) More Precision optoncdt // Laser displacement sensors (triangulation) 1 High Speed PSD Sensors optoncdt 1610 / 1630 INTER FACE Nine models with measuring ranges from mm to 100 mm Sensor head and separate

More information

Digital Measurement Metrology, Inc. Bulletin No Digital Measurement Metrology, Inc PRECISION IS OUR VISION

Digital Measurement Metrology, Inc. Bulletin No Digital Measurement Metrology, Inc PRECISION IS OUR VISION Bulletin No. 2021 Profile Projectors A series of midsize profile projectors featuring bright, 12.40" (315mm) diameter screens and easy-to-operate XY measurement tables. Easy-to-read digital counters are

More information

DFP Series Fiber Photoelectric Amplifiers

DFP Series Fiber Photoelectric Amplifiers DFP Series Fiber electric Amplifiers Part Number Compact rectangular plastic DIN-rail mount- DC models available DIN-rail mounting 12-turn potentiometer sensitivity setting with illuminated scale NPN or

More information

IF84M60. 84" Interactive Flat Panel Displays

IF84M60. 84 Interactive Flat Panel Displays 84" Interactive Flat Panel Displays PANEL MONITOR CONNECTIVITY H-Freq 270 khz RGB Input VGA In Max. Pixel Freq. 74.25 MHz Video Input HDMI 1.4 + HDMI 2.0 V-Freq 120 Hz Audio Input Line-in Jack Size 84"

More information

The Council for Optical Radiation Measurements (CORM), NIST July 30 - Aug 1, 2018

The Council for Optical Radiation Measurements (CORM), NIST July 30 - Aug 1, 2018 Study of the optical properties of black materials at solar reflective wavelengths in support of instrument development and satellite sensor calibration 1Jinan Zeng, 2 Nathan Kelley, 3 James J. Butler,

More information

More Precision. ELTROTEC // Industrial Endoscopes

More Precision. ELTROTEC // Industrial Endoscopes More Precision ELTROTEC // Industrial Endoscopes Cameras 35 ELTROTEC Flexcam For rigid and flexible endoscopes Completely flexible use due to one-cable connection Upgrade to video endoscope Description:

More information

Chapter 3. Experimental Procedure

Chapter 3. Experimental Procedure Chapter 3 Experimental Procedure 33 3.1 Burner Systems Startup 3.1.1 Instrumentation power up The instrumentation of the burner including the PC need to be turned on, in order to provide safe ignition

More information

Efficient and Simple Precision. Laser Processing Head PDT-B

Efficient and Simple Precision. Laser Processing Head PDT-B Efficient and Simple Precision Laser Processing Head PDT-B Modules HIGHYAG PDT-B in action Tactile sensor: guides the laser focus Seam tracking The tactile sensor guides the focusing for laser welding

More information

CUBE. Diode Laser System. Superior Reliability & Performance

CUBE. Diode Laser System. Superior Reliability & Performance Features Compact and modular OEM design Complete CDRH safety features for scientific and laboratory use TEC temperature-stabilized and conductively cooled through baseplate Analog and digital modulation

More information

Operating Microscope OM-18. A i m i n g a t n e w l e v e l s i n q u a l i t y

Operating Microscope OM-18. A i m i n g a t n e w l e v e l s i n q u a l i t y Operating Microscope OM-18 A i m i n g a t n e w l e v e l s i n q u a l i t y Operating Microscope OM-18 Compact Microscope Diverse illumination optics Protection against phototoxicity Apochromatic objective

More information

Hexapod Motion Controller with EtherCAT

Hexapod Motion Controller with EtherCAT Hexapod Motion Controller with EtherCAT Control a 6-Axis Positioning System via Fieldbus Interface C-887.53x Integration into an automation system Synchronous motion in 6 axes Cycle time 1 ms Commanding

More information

Infrared Cameras. The most portable infrared online camera. Innovative Infrared Technology

Infrared Cameras. The most portable infrared online camera. Innovative Infrared Technology Infrared Cameras The most portable infrared online camera Temperature measurement -20 C to 1500 C Small cameras - Ideal for OEM applications Up to 128 Hz for fast processes Including software package and

More information

More Precision. 2D/3D laser scanner (laser profile sensors)

More Precision. 2D/3D laser scanner (laser profile sensors) More Precision. scancontrol 2D/3D laser scanner (laser profile sensors) 4 Technical details Extremely compact design The design of the scancontrol 29x series is focussed on minimal size and low weight.

More information

1.3 Customized Solutions (OEM)

1.3 Customized Solutions (OEM) 1.3 Customized Solutions (OEM) Ophir The World Leading Source for Custom Designed Laser Measurement Solutions 1.3.1 Introduction Many laser systems manufacturers need to have a measuring capability built

More information

More Precision. thermoimager TIM // Compact thermal imaging cameras

More Precision. thermoimager TIM // Compact thermal imaging cameras More Precision thermoimager TIM // Compact thermal imaging cameras 14 Thermal imaging camera for hot metal surfaces thermoimager thermoimager Short wavelength infrared camera for high temperature s of

More information

E (sensor) is given by; Object Size

E (sensor) is given by; Object Size A P P L I C A T I O N N O T E S Practical Radiometry It is often necessary to estimate the response of a camera under given lighting conditions, or perhaps to estimate lighting requirements for a particular

More information

CinCam CCD - Technical Data -

CinCam CCD - Technical Data - - Technical Data - SENSOR DATA CCD-1201 CCD-1301 CCD-2301 CCD-2302 Format: 1/2 1/3 2/3 2/3 Active area: 6.5mm x 4.8mm 4.8mm x 3.6mm 9.0mm x 6.7mm 8.5mm x 7.1mm Number of pixel: 1388 x 1038 (1.4MPixel)

More information