Pumping stations for wastewater with or without sewage

Size: px
Start display at page:

Download "Pumping stations for wastewater with or without sewage"

Transcription

1 Pumping stations for wastewater with or without sewage Aqualift F Ø 00 Products Illustration and dimensioned drawing Installation depths Class B Class D Pumping station Aqualift F with macerating / cutting pumps in inspection chamber system Ø 00 in PE-LLD Single station/twin station for wastewater with or without sewage For underground installation D: D: D: D: D: D: B B B 87 7 B 87 7 B 87 7 B D D D 87 7 D 87 7 D 87 7 D SPZ 000 float switch controlled, removeable pump, plug in ready (0 V / 0Hz) SPZ 000 pressure sensor controlled, removable pump, IP SDS control unit (0 V / 0Hz) D: D: D: 8 7 B 8 7 B 8 7 B 8 7 D 8 7 D 8 7 D SPZ 000 pressure sensor controlled, removable twin pumps, IP SDS control unit (0 V / 0Hz) 700 / 00 / Ø80 Installation depths D Installation depths (D): D D D mm mm mm Cover plate class A/B (Version B) Cover plate class D (Version D) Resistant to aggressive media, upper section made of polymer, vertically adjustable, cover class A/B, D in cast iron according to EN. Groundwater resistant. Inlet Ø 0, connection for pipe gasket for Ø 0 according to EN 0 and EN - - each for ventilation or conduit pipe. Note: Consider frost free depth of pressure pipe. Pressure pipe Ø 0 mm outside diameter for PVC glue connection, with integrated non-return flap. Current: 0 V ~ 0 Hz. Power cable length: 0 m. For installations without explosion proof requirements Handles groundwater depths up to 000 mm EN 00 (max WC connections) Catalogue.

2 Pumping stations for wastewater with or without sewage Installation example pumping station Aqualift F Ø 00 Professional advantages Pumping station Pump The pumping station Aqualift F Ø 00 can be used for the draining of wastewater with or without sewage below the backwater level, as backwater protection for separator systems and for draining basement apartments or driveways. The wastewater flows with natural gradient to the collecting chamber and is pumped by the integrated pumps SPZ 000 via the backwater loop to a higherlevel sewage channel. The pressure pipe should always be laid frost-free. A control unit takes over the fully automatic pump control from within the building. Float switches or a pressure sensor are available as level sensors. Pressure pipe Pressure sensor Inexpensive complete system For draining wastewater with or without sewage For backwater protection connected to a separator Simple to assemble with light-weight inspection chamber components and easy connection technique. Quick to mount with a high level of pre-fabrication and easy connection using fixed couplings for inlet and pressure pipe and bores with lip gaskets for ventilation and cable piping. Variable upper section inclinable and height adjustable from 00 to 00 mm. Tool-free pump removal The one-hand snap closure feature means that no tools are required to remove the pump for cleaning and maintenance. H [m] SPZ Q [m /h] Type Current type Voltage Current Power P/P RPM Motor protection Operating mode SPZ 000 Alternating current 0 V.9 A 080 W / 0 W 800 min - integrated S - 0 % Catalogue. 7

3 Pumping stations for wastewater with or without sewage Aqualift F Ø 800 / 000 Illustration and dimensioned drawing Pumping station Aqualift F (AP 0) in Komfort inspection chamber system Ø 800 / 000 in PE-HD Single station/twin station for wastewater with or without sewage For underground installation AP 0 with removable, float switch controlled pump, plug in ready (0 V power connection) AP 0 Tronic with removable, float switch controlled pump, floats (OFF, ON, ALARM) with control unit (IP ), operating voltage 0 or 00 V DC at 0 Hz, with potential-free contact AP 0 Duo with twin removable, float switch controlled pump, floats (OFF, ON, ON, ALARM), with control unit (IP, operating voltage 0 or 00 V DC at 0 Hz, with potential-free contact Installation depths Products Komfort inspection chamber system Ø 800 D: D: D: 0 V 0 V 0 V 800-HA-0B 800-HA-0B 800-HA-0B 800-HA-0D 800-HA-0D 800-HA-0D D: D: D: D: D: D: Komfort inspection chamber system Ø 000 D: D: D: 0 V 0 V 0 V 000-HA-B 000-HA-D 000-HA-B 000-HA-D 000-HA-B 000-HA-D D: D: D: Voltage 0 V 0 V 0 V 00 V 00 V 00 V 00 V 00 V 00 V Class B 800-HA-B 800-HA-B 800-HA-B 800-HA-B 800-HA-B 800-HA-B 000-HA-B 000-HA-B 000-HA-B Class D 800-HA-D 800-HA-D 800-HA-D 800-HA-D 800-HA-D 800-HA-D 000-HA-D 000-HA-D 000-HA-D Cover plate class A/B (Version B) Cover plate class D (Version D) Installation depths (D) Ø 800 D mm D mm D mm Installation depths (D) Ø 000 D 0-0 mm D 0-0 mm D 0-0 mm Inspection chamber system KESSEL Ø 800 / 000 in PE-HD water-tight, resistant to aggressive media, upper section made of polymer, continuous height and level adjustment, cover class A/B, D in cast iron according to EN. Groundwater resistant. Inlet Ø 0, connection for pipe seal for Ø 0 according to EN 0 for ventilation pipes and cable piping respectively, pumping volume approx. 0 l Pressure pipe ready mounted with backwater flap, closure valve and float switch for level control with cable length 0 m, pressure pipe connection PE-HD Ø mm and Ø 90 mm. Submersible pump AP 0 Single or twin submersible pump(s) 0.7 kw (without explosion protection), with non-chokable impeller to pump wastewater with or without sewage, submersible (IP 8), electrical cable length 0 m. For installations without explosion proof requirements Handles groundwater depths up to 00 mm 8 Catalogue.

4 Pumping stations for wastewater with or without sewage Installation example pumping station Aqualift F Ø 800 / 000 Professional advantages Pumping station Pump H [m] Pressure pipe Float switch The pumping station Aqualift F can be used for the draining of wastewater with or without sewage below the backwater level, as backwater protection for separator systems and for draining basement apartments or driveways. The wastewater flows with natural gradient to the Komfort chamber Ø 800 or 000 and is pumped by the integrated pumps AP 0 to a higher-level sewage channel. The pressure pipe should always be laid frost-free. A control unit takes over the fully automatic pump control from within the building. Float switches are used as level and alarm sensors. Inexpensive complete system For draining wastewater with or without sewage. For backwater protection connected to a separator For draining basements, yards or driveways Variable upper section inclinable and height adjustable from 00 to 00 mm Simple to assemble with light-weight inspection chamber components and easy connection technique. Long-term reliability with an absolute water-tight inspection chamber system which is resistant to sedimentary deposits and aggressive media as well as root infiltration. Fully automated operation with an electrical control unit with manual, off and automatic mode, optical and audible warning and alarm notification, detailed operation and warning display, integrated pump rotation check, anti-blocking function, variable pump on and pump off settings. More output System with stronger pumps available on request 0 8 AP Q [m /h] Type Mono, Tronic, Duo Tronic, Duo Power 0.7 kw 0.7 kw Input power. kw. kw Current A.8 A Voltage 0 V at 0 Hz 00 V at 0 Hz Cable length 0 m 0 m Protection IP 8; without explosion protection IP 8; without explosion protection Catalogue. 9

5 Pumping stations for wastewater with or without sewage Aqualift F Ø 000 Products Illustration and dimensioned drawing Pumping capacity Pressure pipe* Class B Class D Ventilation / cable piping 0 Installation depths (D): D D D D D D D 7 Installation depths D 0-0 mm 0-0 mm 0-0 mm 0-0 mm 0-0 mm 0-0 mm 0-0 mm Pumping station Aqualift F in Komfort inspection chamber system Ø 000 in PE-HD Single station/twin station for wastewater with or without sewage For underground installation Single station Twin station Cover plate class A/B (Version B) Cover plate class D (Version D) Including access steps, water-tight, resistant to aggressive media, upper section made of polymer, continuous height and level adjustment, cover class A/B, D in cast iron according to EN, inlet Ø 0, cable conduit connection Ø 0 according to EN 0 and EN - for ventilation pipes and cable piping respectively. Installation depth from. to m (see table), Pumping volume approx. 80 liters. Pressure pipe ready mounted with backwater flap, closure valve. Single station with three float switches, twin station with four float switches for level control with cable length 0 m, pressure pipe connection PE-HD Ø and Ø 90. Submersible pump TPF. KE / TPF.9 KE explosion-proof, with macerating blades for pumping wastewater with or without sewage, submersible (IP 8), electrical cable length 0 m. Electric control unit for fully automated pump operation, control unit is splash proof (IP ), for wall mounting in dry, frost-free areas, PTB certification for installation in explosion risk areas, voltage 00 V at 0 Hz. With potential-free contact. Handles groundwater depths up to 00 mm (greater groundwater resistance on request) Explosive proof Accessories see page 0 - *) Ø 90 by sawing off. kw. kw. kw. kw. kw. kw. kw.9 kw.9 kw.9 kw.9 kw.9 kw.9 kw.9 kw. kw. kw. kw. kw. kw. kw. kw.9 kw.9 kw.9 kw.9 kw.9 kw.9 kw.9 kw D: /90 D: /90 D: /90 D: /90 D: /90 D: /90 D7: /90 D: /90 D: /90 D: /90 D: /90 D: /90 D: /90 D7: /90 D: /90 D: /90 D: /90 D: /90 D: /90 D: /90 D7: /90 D: /90 D: /90 D: /90 D: /90 D: /90 D: /90 D7: / B 8 0 B 8 0 B 8 0 B 8 0 B 8 0 B 8 70 B 8 70 B 8 70 B 8 70 B 8 70 B 8 70 B 8 70 B B 8 0 B 8 0 B 8 0 B 8 0 B 8 0 B 8 0 B 8 70 B 8 70 B 8 70 B 8 70 B 8 70 B 8 70 B 8 70 B B 8 0 D 8 0 D 8 0 D 8 0 D 8 0 D 8 0 D 8 70 D 8 70 D 8 70 D 8 70 D 8 70 D 8 70 D 8 70 D D 8 0 D 8 0 D 8 0 D 8 0 D 8 0 D 8 0 D 8 70 D 8 70 D 8 70 D 8 70 D 8 70 D 8 70 D 8 70 D D Optional 00 Volt Comfort control unit Art. # D EN 00-0 Catalogue.

6 Pumping stations for wastewater with or without sewage Installation example pumping station Aqualift F Ø 000 Professional advantages Pumping station Pump Domestic wastewater flows with natural gradient to the pumping station and is pumped by the integrated TPF macerator pump over long distances (pressure pipe) into the sewer. The pressure pipe should always be laid frost-free. A control unit takes over the fully automatic pump control from within the building. Float switches are used as level sensors. The system complies with the ATEX product directive and is suitable for installation in potentially explosive atmospheres. H [m] 0 8 Qmin for Ø mm* Qmin for Ø 90 mm* 0 * according to EN 0- Pump type Power (P) Input power (P) Amperage Fuses Voltage Cable length Protection TPF. kw TPF. KE. kw.7 kw. A x A surge-proof 00 V at 0 HZ 0 m Length, 7 x. mm IP 8 Ex-protection Q [m /h] H [m] TPF.9 kw Qmin for Ø mm* Pump type Power (P) Input power (P) Amperage Fuses Voltage Cable length Protection Pressure pipe Float switches Qmin for Ø 90 mm* 0 0 TPF.9 KE.9 kw. kw. A x A surge-proof 00 V at 0 HZ 0 m Length, 7 x. mm IP 8 Ex-protection Q [m /h] Variable upper section inclinable and height adjustable from 00 to 00 mm Comfort control unit (optional) with mains power ON / OFF switch and multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook Simple to assemble with light-weight inspection chamber components and easy connection technique. Quick to mount with a high level of pre-fabrication (bottom part of inspection chamber with pressure pipe) and easy connection using fixed couplings for inlet and pressure pipe and bores with lip gaskets for ventilation and cable piping. Long-term reliability with an absolute water-tight inspection chamber system which is resistant to sedimentary deposits and aggressive media as well as root infiltration. Fully automated operation with an electrical control unit with manual, off and automatic mode, optical and audible warning and alarm notification, detailed operation and warning display, integrated pump rotation check, anti-blocking function, variable pump on and pump off settings. Systems with macerator - permit the realisation of smaller dimensioning of the pressure pipes and longer distances to the sewage system. High pumping volume thanks to the pump chamber. Additional reserve volume if the system should fail e.g. in the event of a power cut. Further inlets up to Ø 0 can be attached on site, Ø 00 or larger in the factory. Suitable for installation in explosion risk areas Catalogue.

7 Pumping stations for wastewater without sewage Aqualift S Ø 00 Products Illustration and dimensioned drawing Pump KTP / GTF Class B Class D 700 / 00 / Ø80 Installation depths D Installation depths (D): D D D mm mm mm Pumping station Aqualift S in inspection chamber system Ø 00 in PE-LLD Single station/twin station for wastewater without sewage For underground installation KTP 00 / GTF 000 float switch controlled removable pump for conductive or non-conductive fluids. Input power (P): 0.8 /.8 kw. KTP 00 / GTF 000 Tronic with removable, pressure sensor controlled pump for conductive or non-conductive fluids, with SDS control unit. Input power (P): 0.8 /.8 kw. KTP 00 / GTF 000 Duo with removable, pressure sensor controlled twin pumps for conductive or non-conductive fluids, with SDS control unit. Input power (P): x 0.8 /.8 kw. Cover plate class A/B (Version B) Cover plate class D (Version D) Inspection chamber system Ø 00 in PE-LLD, resistant to aggressive media, upper section made of polymer, vertically adjustable, cover class A/B, D in cast iron according to EN. Groundwater resistant. Inlet Ø 0 (KTP 00), Ø 0 (GTF 000), connection for pipe seal for Ø 0 according to EN 0 and EN - - each for ventilation or cable pipe, Note: Consider frost free depth of pressure pipe Pressure pipe Ø 0 mm outside diameter for PVC glue connection, with integrated non-return flap, 0 mm max solid size, Current: 0 V ~ 0 Hz. Power cable length: 0 m. D: KTP 00 D: KTP 00 D: KTP 00 D: GTF 000 D: GTF 000 D: GTF 000 D: KTP 00 D: KTP 00 D: KTP 00 D: GTF 000 D: GTF 000 D: GTF 000 D: KTP 00 D: KTP 00 D: KTP 00 D: GTF 000 D: GTF 000 D: GTF B 8 80 B 8 80 B B B B 8 8 B 8 8 B 8 8 B 87 8 B 87 8 B 87 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 80 D 8 80 D 8 80 D D D D 8 8 D 8 8 D 8 8 D 87 8 D 87 8 D 87 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D Handles groundwater depths up to 000 mm EN 00 - Catalogue.

8 Pumping stations for wastewater without sewage Installation example pumping station Aqualift S Ø 00 Professional advantages Pumping station Pump The pumping station Aqualift SØ00 can be used for the draining of wastewater without sewage below the backwater level, as backwater protection for separator systems and for draining basement apartments or driveways. The wastewater flows with natural gradient to the collecting chamber and is pumped by the integrated pumps KTP 00 / GTF 000 to a higher-level sewage channel. The pressure pipe should always be laid frost-free. A control unit takes over the fully automatic pump control from within the building. Float switches or a pressure sensor are available as level sensors. Pressure pipe Pressure sensor Inexpensive complete system For draining wastewater without sewage For backwater protection connected after a grease separator Simple to assemble with light-weight inspection chamber components and easy connection technique. Quick to mount with a high level of pre-fabrication and easy connection using fixed couplings for inlet and pressure pipe and bores with lip gaskets for ventilation and cable piping. Variable upper section inclinable and height adjustable from 00 to 00 mm. Tool-free pump removal The one-hand snap closure feature means that no tools are required to remove the pump for cleaning and maintenance. (see Minilift ) H [m] 0 8 KTP 00 GTF Q [m /h] Current type Voltage Current Power P/P RPM Motor protection Operating mode KTP 00 GTF 000 Alternating current Alternating current 0 V 0 V. A.9 A 80 W / 0 W 80 W / 70 W 800 min min - integrated integrated S S - 0 % Catalogue.

9 Pumping stations for wastewater without sewage Aqualift S Ø 000 Products Illustration and dimensioned drawing Pump KTP / GTF Class B Class D Pumping station Aqualift S in Komfort inspection chamber system Ø 000 in PE-HD Single station/twin station for wastewater without sewage / rainwater For underground installation KTP 00 / GTF 000 float switch controlled removable pump for conductive or non-conductive fluids. Input power (P): 0.8 /.8 kw. KTP 00 / GTF 000 Tronic with removable, pressure sensor controlled pump for conductive or non-conductive fluids, with SDS control unit. Input power (P): 0.8 /.8 kw. D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D7: KTP 00 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D7: GTF B 8 80 B 8 80 B 8 80 B 8 80 B 8 80 B B B B B B B B B 8 80 D 8 80 D 8 80 D 8 80 D 8 80 D 8 80 D D D D D D D D D 00 D D D D D D D 7 Installation depth D 0 Installation depths (D): 0-0 mm 0-0 mm 0-0 mm 0-0 mm 0-0 mm 0-0 mm 0-0 mm KTP 00 / GTF 000 Duo with removable, pressure sensor controlled twin pumps for conductive or non-conductive fluids, with SDS control unit. Input power (P): x 0.8 /.8 kw. Cover plate class A/B (Version B) Cover plate class D (Version D) Inspection chamber system Ø 000 in PE-HD, including access steps, water-tight, resistant to aggressive media, upper section made of polymer, continuous height and level adjustment, cover class A/B, D in cast iron according to EN. Inlet Ø 0, connection drilling with gasket for Ø 0 according to EN 0 and EN - for ventilation pipes and cable piping respectively, Installation depth from. to m (see table), Pumping volume approx. 80 liters. Pressure pipe outlet connection: / inch exterior thread, pressure pipe Ø 0 mm outside diameter for PVC glue connection, with integrated non-return flap, 0 mm max solid size. Current: 0 V ~ 0 Hz. Power cable length: 0 m. Handles groundwater depths up to 00 mm (greater groundwater resistance on request) D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D7: KTP 00 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D7: GTF 000 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D7: KTP 00 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D7: GTF B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 87 B 87 8 B 87 8 B 87 8 B 87 8 B 87 8 B 87 8 B B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 87 B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 87 B 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 87 D 87 8 D 87 8 D 87 8 D 87 8 D 87 8 D 87 8 D D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 87 D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 87 D D EN 00 - Catalogue.

10 Pumping stations for wastewater without sewage Installation example pumping station Aqualift S Ø 000 Professional advantages Gutter drain Pumping station Pump Float switch Variable upper section inclinable and height adjustable from 00 to 00 mm Simple to assemble with light-weight inspection chamber components and easy connection technique. Quick to mount with a high level of pre-fabrication (bottom part of inspection chamber with pressure pipe) and easy connection using fixed couplings for inlet and pressure pipe and bores with lip gaskets for ventilation and cable piping. Long-term reliability with an absolute water-tight inspection chamber system which is resistant to sedimentary deposits and aggressive media as well as root infiltration. Ideal for direct rainwater disposal to the sewage system. The wastewater flows into the gutter drain and then under natural gravity to the Aqualift S pumping station and is pumped by the integrated pumps KTP 00 / GTF 000 into the sewage system. A float switch is used as a level sensor. H [m] 0 8 KTP 00 GTF Q [m /h] Current type Voltage Current Power P/P RPM Motor protection Operating mode KTP 00 GTF 000 Alternating current Alternating current 0 V 0 V. A.9 A 80 W / 0 W 80 W / 70 W 800 min min - integrated integrated S S - 0 % Catalogue.

11 Submersible pumps for wastewater without sewage GTF 000 Products Illustration and dimensioned drawing Pressure connection 9 Submersible pump GTF 000 for wastewater without sewage with/without float switch Connection to pressure pipe / inch. Outlet side / vertical, without macerator, cable length 0 m / inch / inch without float switch with float switch Voltage: 0 V ~ 0 Hz Input power (P): 080 W Max. pumping height: 0 m Max. pumping capacity:, m /h Max. submersible depth: 0 m Max. particle size: 0 mm Pressure connection: / inch side / vertical GTF 000 H [m] 0 LGA Type-tested and monitored guaranteed with tested quality Q [m /h] Current type Voltage Current Power P/P RPM Motor protection Operating mode Alternating current 0 V.9 A 080 W / 0 W 800 min - integrated S - 0 % KTP 00 Products Illustration and dimensioned drawing Pressure connection Submersible pump KTP 00 / KTP 00 TITAN for wastewater without sewage with/without float switch Connection to pressure pipe / inch. Outlet side / vertical, cable length 0 m without float switch with float switch Voltage: 0 V ~ 0 Hz Input power (P): 80 W Max. pumping height: 8 m Max. pumping capacity: 8 m /h Max. submersible depth: 0 m Max. particle size: 0 mm Pressure connection: / inch side / vertical KTP 00 / inch / inch KTP 00 TITAN / inch / inch Special model with titanium shaft Suitable for mechanical and chemical polluted media. Also resistant to chloride-containing media. Not to be used for nitro- and trichloroethylene [m] 7 7 Q [m /h] Current type Voltage Current Power P/P RPM Motor protection Operating mode KTP 00 Alternating current 0 V. A 80 W / 0 W 800 min - integrated S LGA Type-tested and monitored guaranteed with tested quality Catalogue.

12 Submersible pumps for wastewater with or without sewage KTP 00 Products Illustration and dimensioned drawing Pressure connection Submersible pump KTP 00 for wastewater without sewage with/without float switch With backwater flap, pivotable connection, cable length 0 m inch inch without float switch with float switch Input power (P): 80 W. Voltage: 0 V ~ 0 Hz. Max. pumping height: m. Max. pumping capacity: 8 m /h. Max. submersible depth: 0 m. max. particle size: 0 mm. Pressure connection: inch side / vertical Removable input basket - reduction in the water level to 8 mm possible. H [m] LGA Type-tested and monitored guaranteed with tested quality Q [m /h] Current type Voltage Current Power P/P RPM Motor protection Plug KTP 00 Alternating current 0 V.9 A 80 W / W 800 min - integrated Schuko SPZ 000 Products Illustration and dimensioned drawing Pressure connection Submersible pump SPZ 000 for wastewater containing raw sewage with/without float switch with macerator. Connection to pressure pipe / inch. Outlet side / vertical, cable length 0 m / inch / inch without float switch with float switch Voltage: 0 V ~ 0 Hz Input power (P): 080 W Max. pumping height: 0 m Max. pumping capacity: m /h Max. submersible depth: 0 m Pressure connection: / inch side / vertical SPZ 000 H [m] Q [m /h] Current type Voltage Current Power P/P RPM Motor protection Operating mode Alternating current 0 V.9 A 080 W / 0 W 800 min - integrated S - 0 % Catalogue. 7

13 KESSEL-Product information Warning and control units Warning and control units for versatile uses 0 Volt 00 Volt Comfort control units with multi-line digital display INTEGRATED SELF-DIAGNOSIS-SYSTEM With integrated Self-Diagnosis-System and battery buffering continually monitors all electronic functions. TeleControl TELEMETRIC SYSTEM For connection to KESSEL Comfort control units 0 Volt and 00 Volt. Relaying of full text messages to up to three mobile phones. Without SIM card. ATEX VERSION 00 Volt control unit available in ATEX versions suitable for installation in potentially explosive atmospheres. The warning and control units can be used for a wide range of purposes e.g. as warning devices in household and industrial systems as well as for connection to a remote signal sensor. The warning and control units with potential-free contact can be connected to the building management system (BMS). The electronic sensors react to all conductive fluids and the optical sensors to all conductive and non-conductive fluids. POTENTIAL-FREE CONTACT BMS (Building Management System) connection standard with all 00 Volt systems (optional with 0 Volt systems). PROBES Connection possibilities for numerous probes for level measurement, float switches, conductance probes (0 V only), plungers, optical probe (0 V only), level probe (on clamping strip). OPERATIONAL PARAMETERS Operational parameters can easily be custom set by operator - Control unit also for use with pumps from other manufacturers. 8 Catalogue.

14 Read-out of the electronic operating log and simple parameter adjustments store read-out data on USB flash drive load to PC and transmit by read in optimised data again MENU NAVIGATION User-friendly menu navigation in six languages with multi-lingual display. ELECTRONIC LOG-BOOK Electronic log-book function past history of pump operation is shown on digital control unit display. USB-CONNECTION PORT Includes internal USB connection port for 0 Volt control units. For read-out of electrical logbook and down / uploading of operational parameters. USB housing socket optional. READY FOR CONNECTION 0 Volt control unit ready for connection by coded connectors for pumps and pressure sensor - no need for a qualified electrician for connection. Also suitable for third-party pumps Catalogue. 9

15 Warning and control units 0 V Comfort control unit Products Illustration 0 V Comfort control units Mono Duo Mono-/Duo control unit extremely versatile sensor system for measuring the level of wastewater with and without sewage. Including plunger for pneumatic level measurement. For greasy wastewater or wastewater at higher temperature only in connection with a small compressor for bubble formation (Art. # 8 08) with pressure sensor*/without extra alarm probe 0 m pressure hose (can be extended to m) 8 7 D 8 7 D with pressure sensor*/conductance probe with separate conductance probe for alarm level measurement 0 m pressure hose (can be extended to m) m cable (cannot be extended) 8 7 DL 8 7 DL with pressure sensor*/float switch with separate float switch for alarm level measurement 0 m pressure hose (can be extended to m, up to 0 m on request) 0 m float switch cable (can be extended to 0 m) 8 7 DS 8 7 DS with pressure sensor*/optical probe with separate optical probe for alarm level measurement and failure detection of the optical probe via the control unit 0 m pressure hose (can be extended to, up to 0 m on request) m cable for optical probe (can be extended to 0 m) 8 7 DO 8 7 DO Mono-/Duo control unit sensor system for level measurement for wastewater without sewage. With float switches to measure ON, ON (only 8 7-S) and OFF levels. with float switch/without extra alarm probe 0 m float switch cable (can be extended to 0 m) 8 7 S 8 7 S with float switch*/float switch with separate float switch for alarm level measurement 0 m float switch cable (can be extended to 0 m) 8 7 SX 8 7 SX *air compressor available for pressure switches with over 0 m cable 0 Catalogue.

16 Warning and control units 0 V Comfort control unit Products Illustration 0 V Comfort control units Mono-/Duo control unit Mono Duo Extremely versatile sensor system for measuring the level of wastewater with and without sewage. Including level probe for pneumatic level measurement and failure detection of the level probe via the control unit. For greasy wastewater or wastewater at higher temperature, the use of a small compressor is not necessary with level probe/without extra alarm probe 0 m level probe cable (can be extended to 0 m) with level probe/float switch with float switch for alarm level measurement 0 m level probe cable (can be extended to 0 m) 0 m float switch cable (can be extended to 0 m) P 8 7 P 8 7 PS 8 7 PS Mono-/Duo control unit sensor system for level measurement for wastewater without sewage. Including alarm level measurement. Not suitable for rainwater or non-diluted condensate. Including conductance probes for the measuring of ON, ON (8 7-LLF/87-LLV only), OFF and ALARM level. Switching points cannot be adjusted freely. 9 0 Mono control unit 9 with conductance probe/conductance probe Level ON/OFF fixed, alarm level can be adjusted m cable for conductance probe Duo control units LL - 0 with conductance probe/conductance probe ON fixed/on variable/alarm with fixed distance to ON m cable for conductance probe LLF with conductance probe/conductance probe ON variable/on fixed/alarm with fixed distance to ON m cable for conductance probe) LLV Level probe level probe cable 0 m Float switch float switch cable 0 m float switch cable 0 m V Comfort control unit Products Illustration 00 V Comfort control unit Mono Duo suitable for max. switching current from - to. -.0 A Mono.0 -. A Mono A Mono x. -.0 A Duo x.0 -. A Duo x A Duo. -.0 A ATEX version, Mono.0 -. A ATEX version, Mono x. -.0 A ATEX version, Duo x.0 -. A ATEX version, Duo Catalogue.

17 Warning and control units Warning units / 0 V Comfort control units / 00 V Comfort control units Accessories Illustration TeleControl telemetric system for connection to KESSEL Comfort control units 0 Volt and 00 Volt. Relaying of full text messages to up to three mobile phones. Without SIM card TeleControl antenna booster for TeleControl telemetric system incl.. m cable to improve reception. With magnetic base Antenna booster extension cable cable length. m Alarm unit with electrode probe with optical probe for article numbers: Connector set for connection to pump/probe cables for connection to the coded connectors from 8 7 / Audible alarm cable length 0 m suitable for all warning- and control units 0 Potential-free contact suitable for all warning- and control units USB housing socket for routing the USB connection to the outside of the housing suitable for 0 Volt Comfort control units Mono/Duo 8 78 Cable extension set (for motor) 0 m cable length A maximum of two cable extension sets can be connected Cable extension set (for probe) 0 m cable length A maximum of two cable extension sets can be connected Compressor set for use in combination with lifting stations and pumping stations with pressure control: prevents soiling, compensates leaks, avoids the formation of condensate in the pressure hose, makes operation of systems possible with pressure hose lengths > 0 m, including T-piece connection, including 0 m pressure hose 8 08 Catalogue.

18 Individual Solutions Pumping station Aqualift F Duo (TPF. / TPF.9) for free-standing installation (Illustration shows Art. # 000-HA F and Art. # TPF KE DUO) Ø Komfort chamber system Ø 000 Quick release odor tight access cover Inlet Ø 0 mm Pressure outlet Ø= /90 mm Connection seal Ø 0 (cable conduit and ventilation connections) Control unit Duo, level control 7 Twin pumping system with pump type TPF. KE or TPF.9 KE Tender text: Pump chamber Ø 000 with wastewater lifting station Aqualift F Duo with pump type TPF KE for free-standing set-up in frost-free rooms, made of polyethylene PE-HD, waterproof, resistant against aggressive wastewater. Cover hood made of plastic, with quick action closure, sealed odour-tight. Inlet muff made of PE-HD, connection for Ø 0 according to EN 0 and EN - one each for ventilation and cable conduit. Chamber system: Komfort Ø 000 Design height: 0 mm Diameter (Ø): mm Inlet: up to Ø 00 Type of cover: Cover hood, odour-tight Pressure connection: Ø /90 mm Pumping medium: wastewater with and without sewage Pump control: float control Catalogue.

19 Individual Solutions Pumping station Aqualift F Duo, with overflow channel and backwater valve FKA (Illustration shows Art. # 8 0B and chamber system Komfort Ø 000 with Staufix FKA) T Tmin= 00 Tmax= 00 0 T 080 during bei Rückstau backwater Pumping station Aqualift F Duo Chamber system Komfort Ø 000 Channel passage with overflow opening Backwater valve Staufix FKA for wastewater with/without sewage Outlet for pressure pipe Loop via backwater level Catalogue.

20 Individual Solutions Pumping station Aqualift F Duo, with overflow channel and backwater valve FKA Function: Standard operation: In standard operation, the connected drainage fixtures can drain by means of natural gravity through the open channel to the sewer. Backwater protection: If there is any backwater from the sewer, the sensor system in the backwater valve Staufix FKA detects backwater in the drain pipe and closes the motor-driven flap, thus securing the building. Disposal during the backwater phase Any wastewater from the building which occurs during this phase pours through the overflow opening into the pumping station. When the respective switching level is reached, the wastewater is disposed of by the pumping station into the sewer via the pressure pipe against the pressure of the backwater. Standard operation: After backwater the backwater valve Staufix FKA automatically re-opens, the connected drainage fixtures can be drained through the open channel again. Tender text: Pumping station Aqualift F (Duo system) for wastewater with or without sewage, for underground installation, made of polyethylene PE-HD with access steps, watertight, resistant against aggressive wastewater. Polymer upper section for continuous height and level compensation, cover plate made of cast iron according to EN. Connection hole with sealing gasket Ø 0 in accordance with EN 0 and EN - for ventilation and cable conduits respectively, pump volume approx. 00 l. Pressure pipe pre-assembled with backwater flap, closure valve and float switches for level control. Two submersible pumps in explosion-protected version, with cutting unit for pumping wastewater with and without sewage, flood-proof. Electric control unit for fully automatic pump control, splashwater-proof, for wall mounting in dry, frost-free areas of the building, PTB approval for potentially explosive areas (ATEX), with potential-free contact. Chamber system: Komfort Ø 000 Standard: EN 7 Installation depth: - mm Inlet depth: - mm Inlet: passage channel Ø with overflow opening Pressure socket: Ø mm / Ø 90 mm Type of cover: unscrewed Load class: B (. t) Pump type: (optional) Pumping station: Aqualift F (Duo system) Pump type: TPF. KE Standard: EN 00- Feed rate: max. m³/h Pumping height: max. 7. m Rated power: x. kw Input power: x.7 kw Operating voltage: 00 V DC Rated frequency: 0 Hz Rated current:. A Fuse protection: x A slow-blow Protective rating (pumps): IP 8 EX-protection Protective rating (control unit): IP Cable length: 0 m (7 x. mm ) Pumping station: Aqualift F (Duo system) Pump type: TPF.9 KE Standard : EN 00- Feed rate: max. 0. m³/h Pumping height: max..0 m Rated power: x.9 kw Input power: x. kw Operating voltage: 00 V DC Rated frequency: 0 Hz Rated current:. A Fuse protection: x A slow-blow Protective rating (pumps): IP 8 EX-protection Protective rating (control unit): IP Cable length: 0 m (7 x. mm ) Catalogue.

21 Individual Solutions Lifting station Aqualift F XL 900 liters Lifting station Aqualift F XL 900 L for free standing installation Tank volume: 900 liters Pump volume: 00 liters Twin station with two SPF pumps for wastewater with or without sewage for free-standing installation in frost-free rooms Consisting of: Two Polyethylene storage chambers, with air pressure level detector, clean-out opening. Spigots for vertical inlet Ø 0 mm/0 mm, ventilation Ø 7 mm and for manual diaphragm pump Ø mm. Horizontal inlet Ø 0 mm to Ø 00 mm by sawing. Pressure sensor controlled twin wastewater pumps with non-chokable impeller to pump wastewater with or without sewage (open channel passage 0 mm). Pump is rated submersible (IP 8), power cable length 0 m. Operating mode: S: Continous duty S: 0 % power on duration Vertical/ horizontal outlet with integrated non-return valve, with/without closure valve (provided loose), with hose section or flange. Comfort control unit with mains power ON / OFF switch and multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook; control unit is splash proof (IP ), wall mounted, voltage 0 V or 00 V at 0 Hz.With potential-free/bms contact (optional on 0 V models). Pumps for collection tank Illustration and dimensioned drawing Illustratin shows AQUALI000D 0 0 AQUALI000D Pump KTP / GTF Sensor Aqualift F Duo pumping system for installation in on-site collection tank Twin pump system for sewage free wastewater (rainwater or non-wc wastewater) For installation in existing collection tanks with: PE-HD fixing mount for installation and mounting of pumping system Two removable GTF 000 / KTP 00, 0V/ 0Hz Pressure sensor level control for conductive and non conductive liquids With Aqualift Comfort 0 Volt duo control unit Pressure piping with non-return flap and closure lever - Pressure connection: OD0 mm pressure pipe for PVC glue connection - With Comfort control unit for wall mounting in dry, frost protected rooms, splash-proof, fully automated pump level control with optical and audible alarm system, detailed operation and warning status in multiple line digital display. Optional forwarding of alarm and fault message via GSM interface GTF 000 GTF 000 KTP 00 KTP 00 H [m] 0 8 Pressure sensor Floater Pressure sensor Floater AQUALI000D * AQUALI000DS * AQUALI00D * AQUALI00DS * 8 0 Q [m /h] * Custom made product (delivery time on request) Catalogue.

22 Individual Solutions Pumping station in re-enforced corrugated chamber Ø 00 (for installation in groundwater-endangered areas) Tmin= 00 Tmax= 00 Upper cover section, vertically adjustable, with cover class B Chamber system Komfort Ø 000 Load and transport connection hooks Inlet up to Ø 00 Connection seal Ø 0 (cable conduit and ventilation) 7 Access ladder Corrugated chamber Ø 00, with re-enforced, ground plate Tender text: 80 0 KESSEL chamber system Ø 00 made of polyethylene (PE-HD) as a collecting tank for housing a lifting/pumping station, for installation in the ground mm, round version, waterproof, resistant to aggressive wastewater, comprising: Re-enforced corrugated chamber according to DIN 9, Ø 00, further set-up with Komfort chamber system Ø 000 with re-enforced, ground plate Upper section made of thermoset K (Ø = 0 mm) for continuous height and level compensation Cover Cl. B made of cast iron according to EN, with lift-out key Ø00 one PE-HD socket up to Ø 00 (inlet) two connection seals up to Ø 0 (cable conduit, ventilation/aeration) Access ladder made of GRP (CW= 00 mm, rung spacing 0 mm) three load and transport connection hooks Overall depth of the shaft structure: 80 mm + T (Tmin= 00, Tmax= 00) Please note the following: When the system is installed in a groundwater-endangered area, the structure must be anchored on site in concrete as buoyancy protection. 7 Where drop heights of more than m are involved, safety measures must be taken on site. In accordance with GUV V- and BGV D Sect. 9 access ladders and iron rungs for entry which have a fall height of more than.00 m must be equipped with on-site safety measures to prevent people falling. On request and at extra charge, the shaft structure can be fitted with a high-quality safety package in the factory, this comprises: Climbing protection rail made of stainless steel AISI L (.7) Slide mechanism made of stainless steel AISI L (.7) Safety harness (DIN EN ) Entry aid, for entry / exiting chamber (AISI L) Catalogue. 7

SAFETY re-defined. Backwater Protection. The new Staufix FKA/SWA and Pumpfix F series Top-level backwater protection. Quality Safety Success

SAFETY re-defined. Backwater Protection. The new Staufix FKA/SWA and Pumpfix F series Top-level backwater protection. Quality Safety Success SAFETY re-defined Backwater Protection The new Staufix FKA/SWA and Pumpfix F series Top-level backwater protection Quality Safety Success Backwater protection: KE System innovations Body with only mm gradient

More information

Model VDL 115 Vacuum drying chambers for flammable solvents

Model VDL 115 Vacuum drying chambers for flammable solvents Model VDL 115 Vacuum drying chambers for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber

More information

SUBMERSIBLE PUMPS SEWAGE RANGE

SUBMERSIBLE PUMPS SEWAGE RANGE OPERATING LIMITS Flow rates up to: 00 m /h Head up to: 0 m CL Liquid temperature range: + to 0 C* Density of liquid:.0 max. ph of liquid: - Max. immersion depth: 0 m Max. particle size: Ø 0-0 mm ND discharge

More information

Model VD 23 Vacuum drying chambers for non-flammable solvents

Model VD 23 Vacuum drying chambers for non-flammable solvents Model VD 23 Vacuum drying chambers for non-flammable solvents A BINDER vacuum drying oven VD series gently dries materials with homogeneous temperature distribution. The patented expansion shelf technology

More information

Anti-flooding valves and basement drains. Protection and drainage of basement areas

Anti-flooding valves and basement drains. Protection and drainage of basement areas Anti-flooding valves and basement drains Protection and drainage of basement areas Anti-flooding valves and basement drains Anti-flooding valves 6 Anti-flooding basement drains 17 Utility drains without

More information

Dewatering pumps for raw water pumping GRUNDFOS DW RANGE. Dewatering pump kw

Dewatering pumps for raw water pumping GRUNDFOS DW RANGE. Dewatering pump kw Dewatering pumps for raw water pumping GRUNDFOS DW RANGE Dewatering pump 0.7-20 kw efficient state-of-art dewatering pumps Unique user benefits The Grundfos DW pumps form part of a complete range of wastewater

More information

Operating Instruction

Operating Instruction Level and Pressure Operating Instruction VEGASWING 71 A Contents Contents Safety information... 2 1 Product description 1.1 Function and configuration... 3 1.2 Functional principle... 3 1.3 Technical data...

More information

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the

More information

WE TAKE RESEARCH TO HEART SCP + SCPC THE CENTRIFUGAL PUMP SYSTEM

WE TAKE RESEARCH TO HEART SCP + SCPC THE CENTRIFUGAL PUMP SYSTEM WE TAKE RESEARCH TO HEART SCP + SCPC THE CENTRIFUGAL PUMP SYSTEM SCP THE INTEGRATED CENTRIFUGAL PUMP SYSTEM THE CONCEPT The Stöckert SCP contributes to meeting the globally increasing demand for centrifugal

More information

Close-coupled centrifugal pumps

Close-coupled centrifugal pumps CombiBloc Close-coupled centrifugal pumps CombiBloc CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of Johnson Pump s Combi-system, a modular

More information

FEATURES APPLICATIONS OPERATING DATA MATERIALS OF CONSTRUCTION. Flood control

FEATURES APPLICATIONS OPERATING DATA MATERIALS OF CONSTRUCTION. Flood control APPLICATIONS FEATURES Flood control Irrigation Land drainage Pollution control Industry Water refineries Water parks Design OPERATING DATA Capacity:...up to.000 m/h Head:...up to m Max. water temperature:...0

More information

4" MULTISTAGE CENTRIFUGAL SUBMERSED PUMPS COMPLETE WITH MOTOR

4 MULTISTAGE CENTRIFUGAL SUBMERSED PUMPS COMPLETE WITH MOTOR NOCCHI SCM 4 PLUS Maximum rigidity and resistance to water hammer, Strong resistance to the abrasive action of sand, Excellent hydraulic efficiency SCM 4 PLUS submersible pumps consist of a multi-stage

More information

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous

More information

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free

More information

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KMF 720 Constant climate chambers with expanded temperature / humidity range Model KMF 720 Constant climate chambers with expanded temperature / humidity range The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this constant

More information

61F-GP-N8D. Model Number Structure. Ordering Information. Conductive Level Controller. Model Number Legend. List of Models

61F-GP-N8D. Model Number Structure. Ordering Information. Conductive Level Controller. Model Number Legend. List of Models Conductive Level Controller 61F-GP-N8 Compact Plug-in Level for Single or Two-point Level Control of Conductive Materials (Liquids and Solids) Wide range of models: long-distance, high and low-sensitivity,

More information

Immersion Temperature Sensors

Immersion Temperature Sensors 1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or

More information

Instructions for Use. Viega Eco Plus Universal shower WC element. for wall-hung WCs, wall-hung shower WCs, wall-hung WCs with shower WC top

Instructions for Use. Viega Eco Plus Universal shower WC element. for wall-hung WCs, wall-hung shower WCs, wall-hung WCs with shower WC top Universal shower WC element Instructions for Use for wall-hung WCs, wall-hung shower WCs, wall-hung WCs with shower WC top Model Year built: 8161.20 from 08/2015 en_int Universal shower WC element 2 from

More information

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing Vane wheel probe BFA25 for flow measurement of gases and liquids with egrated, configurable transducer UFA in Ex-d housing Drawing 5 Vane wheel flow probe BFA25 (Dimensions see Page 3) Measurable variables

More information

Series description: Wilo-MultiCargo HMC

Series description: Wilo-MultiCargo HMC Series description: -MultiCargo HMC H/m HMC 5 HMC -MultiCargo HMC 3../.. 1 3 5 7 /m³/h Design Self-priming water-supply unit Application Water supply Sprinkling Irrigation and spraying Pumping water from

More information

Flow VA 500/

Flow VA 500/ VA 500/ 520 Verbrauch 79 What are the advantages of the flow measuring technology of CS Instruments? 1) 500 is mounted by means of a standard 1/2 ball valve. During mounting and dismounting the safety

More information

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Conductive Sensors 2 to 4-point level controller Type CL with teach-in Conductive Sensors to -point level controller Type CL with teach-in Conductive level controller Teach-in of sensitivity operating resistance from 0Ω to 0KΩ Multiple combinations of filling and emptying

More information

Installation Instructions and techn. Documentation

Installation Instructions and techn. Documentation Installation Instructions and techn. Documentation Tank-Spion Digital LX-2 / LX-2-R / LX-Q LX-2 Tank monitoring device with level meas. probe. LX-2-R With additional relay control functions. LX-Q With

More information

Multiturn absolute encoder

Multiturn absolute encoder Release date: 207-0-2 :0 Date of issue: 207-0-2 t79_eng.xml Model Number Features Industrial standard housing Ø58 mm PROFINET IRT 0 Bit multiturn Servo or clamping flange Network loop through by means

More information

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Conductive Sensors 2 to 4-point level controller Type CL with teach-in Conductive Sensors to 4-point level controller Type CL with teach-in Conductive level controller Teach-in of sensitivity operating resistance from 0Ω to 0KΩ Multiple combinations of filling and emptying

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix multiturn encoders 5868 and 5888 with CANopen or CANlift interface and optical sensor technology are the right encoders for all CANopen or CANlift applications. With a maximum resolution of

More information

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0) User Manual AquaControl + Rainwater System Controller Item no.: 351027 Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0)7641-5890 Kunststofferzeugnisse D-79 331 Teningen Fax: +49(0)7641-58950 Page 1 Figure

More information

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

1/2 NPTM mm Nose cone fitting Ideal for clean liquids Submersible Liquid Level Transmitter Series: PT-500 1.0 Hex 25.4 mm 7.0 177.8 mm Re-Usable cage fitting Ideal for dirty liquids 5.63 143 mm 5.33 136 mm 1/2 NPTM 3.5 88.9 mm 1.15 29.21 mm Nose cone fitting

More information

Data sheet: Wilo-Stratos 40/1-8

Data sheet: Wilo-Stratos 40/1-8 Data sheet: Wilo-Stratos 4/1-8 Pump curves 1 2 v 3 4 DN4 m/s,5 1, 1,5 2, 2,5 DN5 H/m Wilo-Stratos 4/1-8 p/kpa Wilo-Stratos 5/1-8 48 1 /min - 1 V 1~23 V - DN 4 / DN 5 8 8 P 1/W n= const 6 383 1 /min - 8

More information

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_ Order number VA 550 housing High-pressure rig for VA 550 recoended for mounting from 10 to 100 bar Order no. 0695 0550 A_...M_ 0530 1155 Order no. VA 570 Order no. 0695 0570 0695 0571 0695 0572 0695 0573

More information

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書 DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書 Read and save these insturctions 2008 Antari Lighting & Effects Ltd. User Manual Antari DNG-200 Low fog Generator Congratulations on the purchase

More information

Model KT 53 Cooling incubators with thermoelectric cooling

Model KT 53 Cooling incubators with thermoelectric cooling Model KT 53 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the

More information

T EN TROVIS Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.

More information

Model KB 400 Cooling incubators with compressor technology

Model KB 400 Cooling incubators with compressor technology Model KB 400 Cooling incubators with compressor technology The powerful virtuoso in cooling incubators for microorganisms: the KB masters temperature ranges from -5 C to 100 C. The new KB series consumes

More information

Assembly and Maintenance

Assembly and Maintenance Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines

More information

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

LC/LCD ranges level controllers

LC/LCD ranges level controllers GRUNDFOS WASTEWATER motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow

More information

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1. Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page

More information

2CP. Centrifugal twin-impeller pumps

2CP. Centrifugal twin-impeller pumps CP Centrifugal twin-impeller pumps Clean water Domestic use Civil use Industrial use PERFORMANCE RANGE Flow rate up to l/min (7 m³/h) Head up to m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid

More information

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure Indication and Adjustment Product Information VEGADIS 61 Level Switching Pressure 2 VEGADIS 61 Contents Contents 1 Product description...4 1.1 Configuration... 4 1.2 Principle of operation... 4 1.3 Adjustment...

More information

Model KB 400 Cooling incubators with compressor technology

Model KB 400 Cooling incubators with compressor technology Model KB 400 Cooling incubators with compressor technology BENEFITS Safe and reproducible incubation conditions even at high environmental conditions Disinfection routine at 100 C MAIN FEATURES Model 400

More information

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34) is dedicated for reliable monitoring of lubrication, hydraulic and insulation oils as well as diesel fuel. In addition to highly accurate measurement of water activity (a w ) and temperature (T), calculates

More information

Model KB 240 Cooling incubators with compressor technology

Model KB 240 Cooling incubators with compressor technology Model KB 240 Cooling incubators with compressor technology The powerful virtuoso in cooling incubators for microorganisms: the KB masters temperature ranges from -5 C to 100 C. The new KB series consumes

More information

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

English. Operating Manual. Conductive point level switch MLR120.  Retain for later reference. Companies / brands of GHM English Operating Manual Conductive point level switch MLR120 Companies / brands of GHM www.ghm-group.de Retain for later reference Table of contents Page 1. Proper use (application areas)... 3 Safety

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

Data sheet: Wilo-Stratos 50/1-9

Data sheet: Wilo-Stratos 50/1-9 Data sheet: Wilo-Stratos 5/1-9 Pump curves H/m 2 5 1 15 2 1 v 1 2 3 1 41 1 /min-1 V 8 3714 1 /min-9 V 3329 1 /min-8 V 6 4 57 1 /min-6 V 2 4 6 P 1/W n= const 4 8 V 2 H/m 2943 1 /min-7 V 2171 1 /min-5 V

More information

Data sheet: Wilo-Stratos 50/1-10

Data sheet: Wilo-Stratos 50/1-10 Data sheet: Wilo-Stratos 5/1-1 Pump curves v,4,8 1,2 1,6 2, 2,4DN 4 m/s,4,8 1,2 DN 5 H/m p/kpa Wilo-Stratos 4/1-1 445 1 /min - 1 V Wilo-Stratos 5/1-1 1 1~23 V - DN 4, DN 5 8 P 1/W n= const 6 314 1 /min

More information

WINSTA. Full Line Catalog 2008/2009

WINSTA. Full Line Catalog 2008/2009 WINSTA Full Line Catalog 2008/2009 5 Contents FULL LINE CATALOG W4, Volume 1 Rail-Mounted Terminal Block Systems FULL LINE CATALOG W4 Rail-Mounted Terminal Blocks Volume 1 X-COM -SYSTEM Terminal Strips

More information

Submersible Liquid Level Transmitter Series: PT-500

Submersible Liquid Level Transmitter Series: PT-500 Submersible Liquid Level Transmitter Series: PT-500 The PT-500 is a rugged submersible pressure transmitter designed for tank liquid level measurement, water and wastewater applications, and well depth

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Compact Plug-in Level s for Single or Two-point Level Control of Conductive Materials (Liquids and Solids) Wide range of models: long-distance, high and low-sensitivity, and two-wired

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 5868 and 5888 with interface and optical sensor technology are ideal for use in all applications with a interface. The encoder supports the isochronous (IRT) mode and is therefore

More information

Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling

Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling 572 Assembly Application Snapping a cover carrier onto the carrier rail. Application examples: cover

More information

Refrigerated incubators with forced convection

Refrigerated incubators with forced convection KB series (E3.1) Incubators Refrigerated incubators with forced convection The most versatile incubator for microorganisms: The BINDER KB series controls a temperature range of -5 C to 100 C. With its

More information

Series DMHF Heat Meter

Series DMHF Heat Meter Series DMHF Heat Meter The Series DMHF adopt the MultiPulse TM Technology, Digital Signal Processing Technology and Error Correction Technology, which are the state-of-the-art non-invasive flow measurement

More information

4W 50Hz 2900 RPM Noryl Pump

4W 50Hz 2900 RPM Noryl Pump 50Hz Noryl Pump DCODE Identification system for Pump x x x xxx x x xx Example :- No of Stage Design No Frequency 50= A /60=B Meter 3 / Hour Mix Flow / Radial Flow Material A=AISI316, B=AISI304 C=Bronze,

More information

Blue e+ chillers with the principle

Blue e+ chillers with the principle Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2-16; P=87 PSI Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,

More information

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA

More information

SYLLABUS FOR PLUMBING & SANITARY TRADE

SYLLABUS FOR PLUMBING & SANITARY TRADE SYLLABUS FOR PLUMBING & SANITARY TRADE Duration at Skills Training Institute (Spread in three months) : 600 Hrs 1. Introduction to ITI : 3 Hrs 2. Introduction to the Trade : 3 Hrs 3. Introduction to Trade

More information

DN40 (1 1/2") - DN200 (8") Hot Tappings

DN40 (1 1/2) - DN200 (8) Hot Tappings DN40 ( /2") - DN200 (8") Hot Tappings TONISCO B30 Hot Tapping Machine is versatile and easy to operate. It has a full range capability of setting valves DN40 DN200 by completing it with proper adapters.

More information

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane Filter Caps for Humidity and Dewpoint Transmitters with probe 12 mm (0.47 ) The right choice of appropriate filter cap is essential for best long term performance in the application. For assistance please

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates 1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for

More information

Oval Gear Meter OGM PLUS

Oval Gear Meter OGM PLUS Precise volume measurement Reliable process control High-grade materials Resistant to chemicals Not affected by changes in viscosity Elados EMP pump coordinated flow rates Direct connection to an EMP E60

More information

robust advanced technology Accessories » for mobile and stationary Ringler suction systems

robust advanced technology Accessories » for mobile and stationary Ringler suction systems www.ringler-gmbh.de robust advanced technology Accessories» for mobile and stationary Ringler suction systems Valid from 01.01.2013 Information Dear Customer, This catalog gives you an important selection

More information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information

Installation and Operation Manual SPC1

Installation and Operation Manual SPC1 Installation and Operation Manual SPC1 BIA-SPC1 rev 5 Page 1 TABLE OF CONTENTS Page QUICK GUIDE DRAINAGE PUMP FLOATS CONNECTED TO PANEL 4-5 QUICK GUIDE DRAINAGE PUMP FLOAT CONNECTED TO PUMP 6-7 QUICK GUIDE

More information

SPARES DIAGRAMS AND STOCK CODES V-RANGE

SPARES DIAGRAMS AND STOCK CODES V-RANGE SPARES DIAGRAMS AND STOCK CODES V-RANGE DC SERIES FROM -00 DC00 DC00-A DC00-WP DC00-A,WP DC00 FIG. PAGE. ~ 00 00 HANDLE HOOD-W=0mm 000 HANDLE-HOOD-W=0 mm 00 BEARING-COLLOR-REAR HANDLE 0 PIN-BEARING-HANDLE

More information

External level devices for conductive point level switch

External level devices for conductive point level switch SENSORS FOR FOOD AND BIOPHARMA. Product Information VNV-2, ZNV-2 CONTROLS External level devices for conductive point level switch Application/Specified usage Point level detection of aqueous, conductive

More information

Specification and Design Catalog. Waterside Economizer

Specification and Design Catalog. Waterside Economizer Specification and Design Catalog Waterside Economizer Table of Contents Waterside Economizer Applications.................................................... 4 Application Notes..................................................................

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

DISSOLVED OXYGEN MEASUREMENT

DISSOLVED OXYGEN MEASUREMENT DISSOLVED OXYGEN MEASUREMENT ACTEON 2030 TRANSMITTER Potentiometric measurement technology Robust, watertight, easy to install, Widescreen graphic display: instant measurements, trend line, relay state,

More information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information Signal conditioning instruments for level switches Conductive VEGATOR C VEGATOR VEGATOR Product Information Content Content Product description..........................................................................

More information

Data sheet: Wilo-Stratos 30/1-8

Data sheet: Wilo-Stratos 30/1-8 Data sheet: Wilo-Stratos 3/1-8 Pump curves 7 337 1 /min - 9 V 6 34 1 /min - 8 V 5 271 4 1 /min - 7 V 239 1 /min - 6 V 3 26 1 /min - 5 V 2 173 1 /min - 4 V 14 1 1 /min - 3 V 2 4 6 8,5 1, 1,5 2, 2,5 Q/l/s

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

7-day room temperature controller

7-day room temperature controller s 2 208 7-day room temperature controller Heating applications REV34.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and large

More information

shop online:

shop online: Process systems Liquid ring vacuum pumps Single stage pumps 8 Alpha series single stage liquid ring vacuum pumps 9 AL series single stage liquid ring vacuum pumps 97 Two stage pumps 00 SHR series liquid

More information

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter A trademark of Spirax Sarco, Inc. Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter Description Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive,

More information

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring

More information

Precision Hand-held Thermometer

Precision Hand-held Thermometer Precision Hand-held Thermometer measuring monitoring analysing Measuring range from -220 C... +1768 C Measuring accuracy starting with ±0.03% MV Large selection of temperature probes PT 100 or thermocouple

More information

Micro calibration bath Models CTB , CTB

Micro calibration bath Models CTB , CTB Calibration technology Micro calibration bath Models CTB9100-165, CTB9100-225 WIKA data sheet CT 46.30 for further approvals see page 3 Applications Calibration in the pharmaceutical industry and in the

More information

KROHNE 12/ GR Installation and Operating Instructions BM 500

KROHNE 12/ GR Installation and Operating Instructions BM 500 KROHNE 12/2003 7.02273.21.00 GR Installation and Operating Instructions BM 500 Subject to change without notice. Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic

More information

EX- Documentation VA 450 / VA 452. thermal mass flow sensor

EX- Documentation VA 450 / VA 452. thermal mass flow sensor EX- Documentation VA 450 / VA 452 thermal mass flow sensor This document contains important information for the installation and operation of the flow sensor in explosive environments. Please read the

More information

Model KB 400 Cooling incubators with compressor technology

Model KB 400 Cooling incubators with compressor technology Model KB 400 Cooling incubators with compressor technology BENEFITS Safe and reproducible incubation conditions even at high environmental conditions Disinfection routine at 100 C MAIN FEATURES Model 400

More information

Ultrasonic Heat Flow Meters

Ultrasonic Heat Flow Meters APPLICATIONS Measuring heat flow Sewage and drainage water with small particle quantity Beverage and food processors HVAC hot and cool water Water and waste treatment Power plants, heat energy boiler feed

More information

Ideal protection for your electrics: häwa cable ducts

Ideal protection for your electrics: häwa cable ducts Ideal protection for your electrics: häwa cable ducts Well Conceived The häwa group has established itself as an innovative and highly competent supplier to machinery and facility equipment companies in

More information

Instruction Manual, Alfa Laval Rotacheck Sensor and Relay

Instruction Manual, Alfa Laval Rotacheck Sensor and Relay Instruction Manual Alfa Laval Rotacheck Sensor and Relay Covering Standard Instruments Instruments delivered with ATEX Certification in accordance with Directive 94/9/EC IM-TE91A663-EN9 ESE01763EN Date

More information

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio LH 00 Spare parts list Forward and reversible plate LH 00 Hatz Electric start 0 mm LH 00 Hatz Electric start 0 mm Bio LH 00 Hatz Electric start 0 mm LH 00 Hatz Electric start 0 mm Bio Valid from serial

More information

TS 981 door control TS 981 Control panel with traffic management for DES. Approvals and certificates

TS 981 door control TS 981 Control panel with traffic management for DES. Approvals and certificates TS 98 door control Control panel with traffic management for GfA ELEKTROMATEN drives with DES digital limit switch Approvals and certificates TS 98 TS 98 / TS 98 FT Type test according to: DIN EN DIN EN

More information

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz GRUNDFOS ALLDOS DATA BOOKLET Measuring amplifiers and controllers for conductivity measurement 50/60 Hz TM042232 if Contents Product features Conex DIS 3 3 Identification Type key,, controller 4 Type key,,

More information

Variable Area Flowmeter DATASHEET

Variable Area Flowmeter DATASHEET Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detecting angular positions of 0 to 360 P1-Ri-DSU35 positioning element included in delivery

More information

GRUNDFOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers. For conductivity measurement (conductive, inductive)

GRUNDFOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers. For conductivity measurement (conductive, inductive) GRUNDFOS DATA BOOKLET Measuring amplifiers and controllers For conductivity measurement (conductive, inductive) Table of contents 1. Product features 3 Conex DIS 3 Conex DIS-C 3 2. Identification 4 Type

More information

3081 Test Leads Test Leads Test Leads

3081 Test Leads Test Leads Test Leads 3081 Test Leads 4 mm safety plug system PVC-lead highly flexible, 0.8 mm 2 Safety plug at both ends Straight/angled, complying with Standard cable length: 500/1000/2000 mm Test Leads with Silicon-Isolation

More information

ProcessCalibrator Model CPH6000

ProcessCalibrator Model CPH6000 Calibration technology ProcessCalibrator Model CPH6000 WIKA data sheet CT 15.01 Applications Calibration service companies/service industry Maintenance facilities Measurement and control laboratories Quality

More information

Datasheet.

Datasheet. Industrial Test & Mixing Equipment Bringing Test Innovation to you Datasheet This product datasheet has been provided by John Godrich & SJ Electronics in Partnership with BINDER www.johngodrich.co.uk www.sjelectronics.co.uk

More information