1 CONTROL UNIT 67409

2 TABLE OF CONTENTS SAFETY INSTRUCTIONS...3 PARTS SPECIFICATIONS...5 CONNECTIONS...6 SLOW-DOWN MODE, DIP SWITCHES LOGIC PROGRAM...7 OPERATING TORQUE ADJUSTMENT...9 BRAKE (SLOW DOWN) LENGTH ADJUSTMENT...9 PAUSE LENGTH ADJUSTMENT...9 LEDS...9 RADIO RECEIVER, START BUTTON CONNECTIONS...0 PHOTOCELLS, BUZZER CONNECTIONS... ELECTRIC LOCK, MAGNETIC LOCK, SOLENOID LOCK CONNECTIONS...2 SAFETY EDGE, FLASHING LAMP, COURTESY LIGHT, TIMER CONNECTIONS...3 POWER SUPPLY, MOTORS, CAPACITORS CONNECTIONS FOR HYDRAULIC OPERATORS...4 POWER SUPPLY, MOTORS, CAPACITORS CONNECTIONS FOR ALPHA OPERATORS...5 ANTENNA, SAFETY GATE, STOP BUTTON CONNECTIONS...6 SELF-LEARNING OF OPERATING TIME FOR SWING GATES OPERATORS...7 PROGRAMMING A TRANSMITTER ON START...20 PROGRAMMING A TRANSMITTER ON PARTIAL START...20 LOOP DETECTOR WIRING...2 TROUBLESHOOTING...23 SALES CONDITIONS AND WARRANTY

3 WARNING: Not following these instructions may cause severe injury or death to person IMPORTANT SAFETY INSTRUCTIONS WARNING - To reduce risk of severe injury or death: ) READ AND FOLLOW ALL INSTRUCTIONS END USER ISTRUCTIONS 2) Never let children operate or play with door controls. Keep the remote control away from children. 3) Always keep the moving system in sight and away from people and objects until it is completely closedor stopped. NO ONE SHOULD CROSS THE PATH OF THE MOVING SYSTEM. 4) Test the system gate operator monthly. The system MUST reverse on contact with a rigid object or when an object activates the non-contact sensors. To obtain a reverse on contact with an object on hydraulic linear and in-ground operators SEA recommend to install the patented safety device SAFETY GATE for each leaf. After adjusting the force or the limit of the travel, retest the gate operator. Failure to adjust properly the gate operator properly can increases the risk of severe injury or death. 5) Use the manual release only when gate is not moving 6) KEEP GATES PROPERLY BALANCED AND MAINTAINED. An improper balancing or maintenance increases the risk of severe injury or death. Have a qualified service personal to make repairs to cables, spring assemblies and other hardware. 7)The entrance with a gate operators system is for vehicles only. Pedestrian MUST use separate entrance. 8) Every gate operator installation MUST have secondary protection devices against entrapment, such as edge sensors and photo beams more in particularly in places where the risk of entrapment is more likely to occure. The installer is responsible for grounding the operator system, for providing the main power breaker switch, and for making sure that the entire gate systems meets all applicable electrical codes. SAVE THESE INSTRUCTIONS 3

4 GROUNDING IMPORTANT SAFETY INSTRUCTIONS 4 Good grounding and proper surge suppression are an integral part of proper installation for a gate operator system. One or all of the following may require surge suppressors: high voltage power lines, low voltage power lines, telephone lines, data lines, low voltage control lines and loops. How much surge suppression is required depends upon how susceptible the area is to lightning and power surges. Regardless, good grounding is essential. To realize maximum protection, proper grounding and proper surge suppression is absolutely necessary. If the circuit breaker box is located close to the gate operator system, for example, in a guard house, then the ground from that circuit can be used to ground the gate operator system. Eliminate all 90 bends in ground wires and keep a minimum of three feet between the surge suppressor and the equipment being protected. If the power source or circuit breaker box is not located close to the gate operator system an Isolated Ground Zone (IGZ) needs to be created. An IGZ can also be created if the circuit breaker box is located close by the gate operator system. An IGZ is an imaginary circle drawn around the gate operator system. The gate operator system not only includes the gate operators and control panel, but all of the accessories and devices associated with it at that controlled entry point. This includes loop detectors, card readers, digital entries, telephone entries, any device that has a ground or requires a ground and ali of the surge suppressors. The ground bus is a common ground point calied a Single Point Ground (SPG). It is used to bond all the equipment and device grounds in the IGZ together. The SPG is very important because it helps eliminate different ground potentials that can be present on the equipment. In such cases, equipment damage occurs even with surge suppressors. Do not use or connect the ground wire coming from the circuit breaker box. By using an Isolated Ground Zone, you are separating the gate operator system from the house or building ground. This eliminates ground potentials. It is recommended that the ground bus be located in a separate NEMA type enclosure. All grounds will be tied to this ground bus. Some points to remember: Keep all ground wires as straight as possible. Do not have any sharp 90 bends. Have a minimum of 3 feet of wire between the surge suppressor and the equipment being protected. Equipment ground wire should be a minimum of 2 AWG. The main ground wire from the bus bar to the ground rod shouid be an 8 or 6 AWG copper wire. Ground rod should be a minimum of 0 feet in length, longer depending on local soil conditions. For more information regarding good grounding practices check: National Electric Code art. 250; IEEE Emerald Book, standard 00; International Association of Electric Inspectors. SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS

5 PARTS SPECIFICATION CMR CNP CN4 LED4 LED5 LED6 U2 J DIP CN LEDP U Rv3 Rv2 Rv P2 RL RL2 RL3 F2 LED LED2 LED3 LED4 LED5 LED6 LED7 LED8 LED9 LED0 LED LED2 LED3 F CN2 GREEN CN3 ORANGE LED = Auxiliary input LED2 = Partial Start LED3 = Start LED4 = Limit switch in closing Motor 2 LED5 = Limit switch in opening Motor 2 LED6 = Limit switch in closing Motor LED7 = Limit switch in opening Motor LED8 = Photocell 2 LED9 = Photocell LED0 = 24V Auxiliary output LED = Tx Photocell output LED2 = Troubleshooting LED LED3 = Electric Lock LED4 = Encoder (reversing sensor) 2 LED5 = Encoder (reversing sensor) LED6 = Stop LEDP = Programming CN = 24V input / output connector CN2 = 24V input / output connector (green) CN3 = Motors and Power supply connector (orange) CN4 = 24Vac Photosync connector Rv = Motor torque adjustment Rv2 = Brake length adjustment (slow down length) Rv3 = Pause time adjustment = Operating time memory button P2 = Programming transmitters button DIP = Dip-switch Function Setting F = Output and motor fuse (6.3AT) F2 = Accessories fuse (2A) J = Slow-down adjustment RL = Motor Power Supply Relay RL2 = Motor Operating Direction Relay RL3 = Garden Light Relay U = Micro-controller U2 = EEPROM memory CMR = Receiver module connector CNP = PALM connector 5

6 B r own C o mmo n Au xi li ar y in pu t Opening Wh ite Part i al START Closing W h i t e START Com m on Limi t switch c losing M o t or 2 Limit s w itch openin g M o t or 2 Li mit sw it c h cl os ing Mo t or Li mit sw itch op ening Mo t or Photoc e l l 2 (ope n in g) Photocel l (c l o s in g) C o mmon 24V d c Auxili ar y 24V Trans m itter photocell Flasher 5V Neutral Ground Lo ck 2 V Phase Opening Closing Com m on Buzzer 24 V 24V 400 ma ma x Co mm on CN2 (Green) CONNECTIONS ATTENTION NOTE: In the configuration of the swing gate double leaf the limit switches must not be bridged. CN3 (Orange) Cap a citor M2 ~ M2 Capacito r M ~ M Cour t esy light 5V CN CN4 DIP ON ON= Function Active AE R I A L Gr e en Rev ersi ng sen sor Re v. se nso r po we r sup p ly Re ver sn i g sen so r 2 Rev ersi ng sen so r STOP 2 24V~ Note: For the power supply of the synchronized photocells Operating logics Auxiliary input configuration Leaf delay in opening and closing Pre-flashing Automatic closing Photocell autotest Reversing sensor (Safety Gate) Soft start Brake (slow-down) Leaf locking Reverse stroke 6

7 SLOW-DOWN MODE, DIP SWITCHES, LOGIC PROGRAM J Choose the slow down modality which can be more appropriate for the installation. Slow-down mode (only DIP 0 ON) 2 : Jumper unconnected 2: Jumper connected J DIP DIP ON WORKING LOGICS Four different working logics can be selected. The programming takes place using DI and DIP2. - MANUAL LOGIC A START command opens the gate. A second START while it is opening stops the motor. A START command while it is closing stops the motor. Important note: For the automatic re-closure, set DIP 6 on ON - SAFETY LOGIC A START command opens the gate. A second START while it is opening reverses the motor. A START command while it is closing reverses the motor. Important note: For the automatic re-closure, set DIP 6 on ON - AUTOMATIC LOGIC A START command opens the gate. A second START while it is opening is not accepted. A START while it is closing reverses the direction. P. N.: for automatic closing, set DIP SWITCH 6 to the ON position. Important note: For automatic closing, set DIP SWITCH 6 to the ON position. Important note: If Dip 6 of the automatic closing is not activated the start in pause will be accepted. - AUTOMATIC LOGIC 2 A START command opens the gate. A second START while it is opening is not accepted. A START during the pause time closes the gate immediately. A START while it is closing reverses the direction. P. N.: for automatic closing, set DIP SWITCH 6 to the ON position. P. N.: For automatic closing, set DIP SWITCH 6 to the ON position. DIP / 2 / 2 / 2 / 2 OPENED CLOSED OFF / OFF ON / OFF OFF / ON ON / ON DI AND DIP2 PROGRAMMING FOR THE SELECTION OF THE WORKING LOGIC If Dip and Dip2 are programmed in this way, the control unit will work with Manual Logic If Dip and Dip2 are programmed in this way, the control unit will work with Safety Logic If Dip and Dip2 are programmed in this way, the control unit will work with Automatic Logic If Dip and Dip2 are programmed in this way, the control unit will work with Automatic 2 Logic 7

8 DIP SWITCHES, LOGIC PROGRAM DIP 3 3 OPENED CLOSED OFF ON DIP 3 AND DIP 4 PROGRAMMING FOR AUXILIARY INPUT CONFIGURATION SAFETY EDGE ( N.C. contact) When the Safety Edge Contact opens, the gate reverses direction and stops after about second. A START command is required to restart movement TIMER (N.O. contact) If a TIMER is connected to this input the gate can be opened and kept open as long as the contact remains closed. Using a 24-hour or 7-day timer allows gate opening times to be scheduled as required. When the TIMER contact is open the automatic operation functions according to pre-set logics. DIP OPENED CLOSED PROGRAMMING OF OTHER DIPS FOR OTHER FUNCTIONS ON ON ON ON ON ON ON ON ON LEAF DELAY IN OPENING AND CLOSING Activating this function, the Leaf Delay in opening and closing will be eliminated. Both leaves will work simultaneously. It is advised to activate this function on single leaf applications and/or in applications where the Delay is not required. PRE-FLASHING When this function is activated the flashing lamp and warning light begin flashing about 3 seconds before the motor starts, both when closing and opening. AUTOMATIC CLOSING Activating this function causes the gate to close automatically, after the time set by the trimmer Rv3. This function can be activated independently of the operating logic set (DIP SWITCH and 2). PHOTOCELL AUTOTEST When this function is activated a test is carried out on the photocells before any gate movement takes place. To enable this function the photocell transmitter must be connected to terminals 3 (24V) and 7 (Negative) of connector CN2. The flashing lamp and troubleshooting LED will both flash slowly if a malfunction occurs. ENCODER MANAGEMENT (reversing sensor) The signals sent from an encoder located on the motor or gate are managed when this function is activated. This results in any obstacles found in the gate's path being detected and reverses the gate direction of movement for one second, it stops and waits for commands. The flashing lamp and troubleshooting LED will both flash slowly if a malfunction occurs. With a following start the automation will proceed in slow down speed until it reaches the stop. Note: After two consecutive obstacles the BUZZER will be activated. P.N.: If an encoder is not fitted, set the DIP SWITCH to OFF. Note: The Encoder sensibility can be adjusted through the PALM or through the pushbuttons Ptime and Pcode on board of the control unit. SOFT START When this function is activated, the motor will start at a lower torque to avoid stresses and strains on the gate's mechanical components. The starting torque is a percentage of the normal operating torque. P.N.: It is not advised to operate this function when the gate is very heavy or does not run smoothly. BRAKING (slow-down) AT LIMIT SWITCH When this function is activated motor speed reduces slowly before the limit switch is reached or before the end of the operating time. This function is designed to bring the leaf gently up to the stop position and prevent the gates clashing. The closing speed is fixed, while the slow-down time can be adjusted using the trimmer Rv2.! Remember to set this DIP in Off position in case of mechanical or hydraulic brake. It is necessary to activate this function to choose the slow-down modality through jumper J. LEAF LOCKING When this function is activated, at the end of the slow-down phase, and when the leaf is up against the mechanical stop, the motor is supplied at maximum power for about second. This increases the oil pressure in the motor and makes the hydraulic lock more effective. P.N.: this function SHOULD NOT be activated when used on sliding gates since it could cause over-running of the limit switches and the automation system to jam. Note2: With the Palm through the function PushOpen it is possible to exclude the tightening of the leaf during the opening phase. REVERSING STROKE This function (to use exclusively on swing gates) is used to facilitate the electric lock release. Before beginning the opening cycle, as soon as the start order is given, the leaves are supplied for about sec. in closing.

9 Rv OPERATING TORQUE ADJUSTMENT This trimmer is used to adjust the motor torque. This adjustment is essential for operators without mechanical or hydraulic anti-crush devices and must be carried out so that there is no risk of people or objects being crushed. It must always be executed in accordance with current legislation on the subject. Rv2 BRAKE (slow-down) LENGTH ADJUSTMENT This trimmer is used to adjust the length of the slowdown. Rv3 PAUSE LENGTH ADJUSTMENT This trimmer allows the PAUSE time to be adjusted between 0 and 20 seconds. Set DIP SWITCH 6 to the ON position to enable automatic closing. P.N.: TURNING THE TRIMMERS CLOCKWISE INCREASES THE TIMES/VALUES LED LED2 LED3 TRIMMER REGULATION, LEDS LED4 LED5 LED6 LED7 - LED LED9 + Rv3 + Rv2 + Rv LED0 LED LED2 LED3 LED4 LED5 LED6 LED (AUX INPUT) LED2 (PARTIAL START) It must be usually switched off and it must switch on when an partial opening control is given. LED3 (START) It must be usually switched off and it must switch on when an opening control is given. LED4 and LED5 (CLOSING LIMIT SWITCH MOTOR 2) / (OPENING LIMIT SWITCH MOTOR 2) LED6 and LED7 (CLOSING LIMIT SWITCH MOTOR ) / (OPENING LIMIT SWITCH MOTOR ) They must be usually switched on and they must switch off when the limit switches are started up. LED8 and LED9 (PHOTOCELL 2) and (PHOTOCELL ) It must be usually switched on and it must switch off when the photocell is darkened. LED0 (24V AUX POWER SUPPLY) LED (TX PHOTOCELL POWER SUPPLY) LED2 (TROUBLESHOOTING LED) If the automation stops to work, the Troubleshooting LED will indicate which safety caused the event through many different flashing spaced out by a second pause. flash = PHOTOCELLS 2 flashes = SAFETY EDGE 3 flashes = ENCODER (reversing sensor) 4 flashes = STOP 5 flashes = PHOTOCELL SELF-TESTING 6 flashes = TRIAC TEST The flashing sequence will be repeated even on the flashing lamp for 5 seconds. LED3 (ELECTRIC LOCK) LED4 and LED5 (ENCODER2) and (ENCODER ) LED6 (STOP) It must be usually switched on and it must switch off when a STOP control is given. LEDP (Programming) ALARM INDICATION BOARD ON CONTROL UNITS GATE The sequence of lightning, intervals of pause, are shown on the flashlight (for ca. 20 sec.) and on the control lamp (until a new START). Number of lightning 2 3 Type of alarm Photocell Safety edge Encoder Number of lightning Type of alarm Stop Photocell self-testing Triac test 9

10 RADIO RECEIVER, START BUTTON CONNECTIONS C + CN2 Com 5 4 Connection of a radio receiver This connection allows to command the total opening/closing of the automation. For the receiver connection make reference to the related instruction manual. + = 24V, - = 0V, C = Contact Com = Common 3 Partial Start To obtain a partial opening (7 second gate opening) connect the key-button wires as in the picture. It is possible to connect other command devices (push button board, radio receiver, keypad). Note: the contact for the partial opening is a N.O. Contac (Normally opened) Note2: the partial opening will be always executed on the M motor. 4 4 Start Button An impulse given to this entrance commands the opening/closing of the automation. It can be given by a key switch, a loop detector, a keypad, etc. To connect the supplied devices (for ex. Loop detector) see the related instructions. 0

11 PHOTOCELLS, BUZZER, CONNECTIONS C C CN2 Photocell self-testing Buzzer (24Vdc) Audible Alarm Use a buzzer 24V of 00 db. The buzzer will be switched on after two consecutive activations of the anticrush sensor. To reset the allarm it is necessary to push the button STOP. Anyway after 5 minuts the buzzer will stop to sound and the automation stands still waiting for commands. 4 7 IMPORTANT: UL325 standards requires an audible alarm to go OFF after 2 consecutive events! detected by the primary entrapment protection of the gate operator (for ex. reversing sensor). Photocells 2 Connection When the photocells beam is crossed, the automation reverses its movement if in closing phase. In opening it causes the stop of the gate until it is occupied, when released the gate returns into open postion. Note: When not used make a jumper between contact 9 and the common. Note : With the PALM device it is possible to set as PHOTOSTOP, that means that it does not allow to the gate to open, while it does not intervene during the remaining opening. + = 24V - = 0V C = Contact Com = Common 5 7 TX RX - + Com 9 N.C. Photocells Connection When the photocells beam is crossed, the automation reverses its movement if in closing phase. To use the photocells self- testing connect the (+) of the TX photocell with contact 3 instead of 5. Note: When not used make a jumper between contact 0 and the common. Note: With the PALM device it is possible to set this photocell as PHOTOCLOSE, that means, that if occupied during the pause, the automation interrupts the same and recloses immediately. + = 24V - = 0V C = Contact Com = Common 5 7 TX - + Com RX 0 N.C.

12 ELECTRIC LOCK, MAGNETIC LOCK SOLENOID LOCK CONNECTIONS CN2 Electric lock exit An electric lock of 2V or of 24 Vdc 5W max can be connected.the electric lock activates at every opening cycle for about,5 s. 6 Magnetic Lock wiring optional board Power for Magnetic Lock N.C. The Power Supply is not provided. 6 7 Magnetic Lock Solenoid Lock wiring optional board Power for Solenoid Lock Solenoid Lock N.O. The Power Supply is not provided

13 SAFETY EDGE, FLASHING LAMP, COURTESY LIGHT, TIMER CONNECTIONS CN2 2 Safety edge input Timer A further safety can be obtained making a connection with the safety edge mentioned on the side. If it is start up, the safety edge reverses the movement of the gate for two seconds and it stops. To use the safety edge, place dip-switches 3 on OFF. Notice: if the safety input is not used, make a Jumper between and 2. 2 With DIP3 on ON it is possible to connect a timer. The Timer executes the timed opening and keeps the gate open for the whole adjusted time CN3 Courtesy Light (5V max 00W) During the working phase, courtesy light stays switched on. Note: With the Palm it is possible to modify this time from 5 to 240 s. 2 Flashing Lamp (5V) The flashing lamp is an important accessory which warns the gate operating. To connect it, connect the wires of the flashing lamp as in the picture. It is possible to activate a pre-flashing of 3 seconds before activating the automation placing Dip 5 on ON. Notice: The warning lamp gives the same warning signals as the LED 2 described in pag

14 HYDRAULIC MOTORS, POWER SUPPLY, CAPACITORS CONNECTIONS M M Com M M Com N G P CN3 Violet Black White Violet Black White Capacitor 2 2 Green Green 6 Capacitor Motor 2 Output for Motor 2 connection M2 M = OPEN/CLOSED Com = COMMON Example Motor Output for Motor connection M M = OPEN/CLOSED Com = COMMON Example 4 Power input Input for the connection of the electric power. P = PHASE N = NEUTRAL G = GROUND NOTICE: for the connection to the electric power see the law in force

15 MOTORS, CAPACITORS, POWER SUPPLY CONNECTIONS for ALPHA M M Com M M Com N G P CN3 Capacitor Capacitor Motor 2 Output for Motor 2 connection M = OPEN/CLOSED M2 Com = COMMON ALPHA Motor Output for Motor connection M = OPEN/CLOSED M Com = COMMON ALPHA Power input Input for the connection of the electric power. P = PHASE N = NEUTRAL G = GROUND NOTICE: for the connection to the electric power see the law in force

16 ANTENNA, SAFETY GATE, STOP BUTTON CONNECTIONS CN CN LEDP Green Brown White White P2 Encoder adjustment procedure on board of the control unit. Keep pressed both Ptime and Pcode buttons for 3 seconds until ledp turns on.. 2. The led turns on and stays on for second, afterwards it reproduces the number of flashes corresponding to the level of the set encoder sensibility (from to 5, where 5 stands for the maximum insensibility) 3. If the set level is not suitable, press the push-button Pcode to increase or Ptime to decrease it. Every impulse corresponds to the increase or the decrease of one unity. 4. After second from the last pressure of the push-button the set sensibility level will be shown through the corrisponding number of flashes. 5. After 3 seconds from the visualization, the procedure will be left and the ledp switches off. Note: Execute the adjustment with still- standing gate. 2 Antenna Connect the antenna as in the picture. Encoder (reversing sensor) on motor 2 (DIP8 ON) The encoder or Safety Gate is a system which detects any obstacle during the operating of the gate. When activated the motor reverses for sec. It is set in the factory on a middle level but can be modified. Low sensibility levels do not allow a fast inversion as required by the En2453 rules. Note: After two consecutive inversions the BUZZER will be activated. Encoder (reversing sensor) on motor (DIP8 ON) The encoder or Safety Gate is a system which detects any obstacle during the running of the gate.when activated the motor reverses for sec. Note: With the PALM device or through the pushbuttons Ptime and Pcode on board of the control unit. it is possible to adjust the sensibility of the encoder on a scale from 0 to 5, where 0 indicates the max. sensibility during the inversion. Note: Every time when there is no current supply and after every osbstacle the automation, when no limit switches are installed, will proceed slowly until it reaches the stop. SAFETY GATE SAFETY GATE Stop Button The pressure of this button stops immediately the motors in any condition /position. With the following start impulse the gate will always go in closure. Note: if it is not used, make a jumper between terminals n 2 and

17 SELF-LEARNING OF OPERATING TIMES FOR SWING GATES OPERATORS STEP (Note: On swing gates with two leaves the limit switches have not to be bridged) Make all the electrical connections and jumpers on all the unused N.C. contacts (photocells, limit switches, etc). If a geared motor equipped with a mechanical or hydraulic anti-crush safety device is being used, set the operating torque (trimmer Rv) to the maximum value and then adjust the motor torque using the special bypass valves or clutch adjustment screws located on the actuators. If a motor without a mechanical or hydraulic anti-crush safety system is being used, set the operating torque to the maximum value ONLY for the self-learning process. Immediately afterwards, set a torque value that will ensure anti-crush safety, in accordance with current legislation. ATTENTION! THIS PROCEDURE IS POTENTIALLY DANGEROUS AND MUST BE CARRIED OUT ONLY BY SPECIALIZED PERSONNEL, ADOPTING ALL SAFETY PRECAUTIONS. 2 STEP 2 Disconnect the power supply (Fig. ), release the gate operator (Fig. 2) and stop the leaves in the half-open position (Fig. 3). Lock the motor (Fig. 4) and turn ON the power (Fig. 5). Fig. Fig. 2 OFF Unlock Example Lock M Fig. 3 M2 Fig. 4 Example Fig. 5 Notice: Encoder activation O N With the safety gate (encoder and encoder 2) on both motors put dip 8 on ON before programming. To exclude its function put dip 8 on OFF avoiding to repeat the selflearning procedure. 7

18 D D D D D RR LL 33 D R R L L 2 2 RL RL E D SELF-LEARNING OF OPERATING TIMES FOR SWING GATES OPERATORS D Press and Hold button (LED P will come ON) until motor M2 will start to close the gate*. CN LE 4 L D5 LE 6 U2 DIP CN4 T Release. RV3 L E D P U RV2 RV P2 F2 LED LE 2 LE 3 LE 4 LED5 L ED 6 L E 7 LE 8 LED9 LED0 L E D L ED 2 L ED 3 F CN2 CN3 * 3 LEDP If the motor start to open the gate, take OFF the power and reverse the motor phases. Make the same type of connection on motor M as well. Repeat the programming procedures (STEP 2). M STEP 3 (from STEP 2) When the leaf reaches the closing mechanical stop, press button (Fig. 6). Motor M will also start a closing cycle. When the gate reaches the closing mechanical stop, press again (Fig. 7). Do not execute this operation if limit switches are installed. Note: If the safety gate is installed you must give the impulse exactly on the stop. M2 M M2 M M2 Fig. 6 The leaf stops and M starts an opening cycle. After a few seconds press once more to set the Leaf Delay in Opening. (The number of seconds waited will result in the delay of the leaf in opening) NOT TO DO IF DIP 4 IN ON POSITION. When the leaf reaches the opening mechanical stop, press again (Fig. 8). Do not execute this operation if limit switches are installed. Motor M2 will also start an opening cycle. When it reaches the opening mechanical stop, press again (Fig. 9). Do not execute this operation if limit switches are installed. Fig. 7 M M2 M M2 8 Fig. 8 Fig. 9

19 SELF-LEARNING OF OPERATING TIMES FOR SWING GATES OPERATORS Motor M2 will start a closing cycle automatically. After a few seconds press once more to set the Leaf Delay in closing. (The number of seconds waited will result in the delay of the leaf in closing) NOT TO DO IF DIP 4 IN ON POSITION When the leaf reaches the closing mechanical stop, press again (Fig. 0). Do not execute this operation if limit switches are installed. At this point motor M will start a closing cycle. When the closing mechanical stop is reached, press again (Fig. ). Do not execute this operation if limit switches are installed. M M2 M M2 Fig. 0 When motor M reaches the closing mechanical Stop, press for the last time. Programming is completed. Fig. 4 Check that the times are saved properly by giving a START command or pressing button. If necessary repeat the learning procedure from stage 2. STEP 4 If used with a motor without a mechanical or hydraulic anti-crush safety device, adjust trimmer Rv to values that will ensure anti-crush safety, in accordance with current legislation. If, after adjusting the operating torque, the operating time is insufficient (e.g. the leaf fails to open or close completely), repeat STEP 2 with the motor torque value set for the normal use of the system. Adjust the slow-'down length (if enabled), using trimmer Rv2. FUNCTION OF THE CONTROL UNIT FOR ONLY ONE MOTOR The Gate 2 control unit can be used for the movement of one single leaf, when swing leaf it s without limit switch. To prepare the control unit for the programming of this function it is sufficient to PUT A JUMPER between the limit switch contacts of the motor M (connected motor) and to exclude the leaf delay (Dip 4 ON). Keep pressed until the motor starts to close, when it reaches the stop in closing press again, and the motor will open. Press after the stop in opening has been reached, the motor will start a closing cycle, when it reached the stop in closing press and the programming is finished. FUNCTIONING OF THE GATE2 CONTROL UNIT FOR A DOUBLE SLIDING GATE It is possible to use the GATE2 control unit also to move a double sliding gate with limit switch. To predispose the unit for the programming of such functioning modality it is sufficient to connect the limit switch connectors of the motors M and M2 and to exclude the leaf delay (Dip 4 on ON ) Press and keep pressed until the motor starts, now the automation continues autonomously with the selflearning of the times. PALM FUNCTIONS: LED4 LED5 LED6 U2 DIP J CN LEDP U Rv3 Rv2 P2 Rv F2 LED LED2 LED3 LED4 LED5 LED6 LED7 LED8 LED9 LED0 LED LED2 LED3 CN4 RL RL2 RL3 F GATE - Administration Visualisation and modification of the following parameters: Working times Leaf delay Partial opening time 2 n. maintenance cycles adjustment Antisqueezing sensibility SAFETY GATE PhotoStop PhotoClose PushOpen ( excludes the pushover during opening phase) CN2 CN3 9

20 E E E E E E E RL3 RL3 R L 2 RL RL PROGRAMMING A TRANSMITTER WARNING: The default card will only accept ROLLING CODE radio transmitters (Ladbird Roll and and Smart Roll) associated with the RF ROLL (433 Mhz Code , 868 Mhz Code ). To program NOT ROLLING CODE transmitters (Smart Dual, Ladybird Dip and Copy and Head) it is necessary to replace the microprocessor with the appropriate kit (Code ) and to insert on the control unit the RF module (433 Mhz Cod , 868 Mhz Cod ). Note: The RF ROLL receivers will be manageable with the SP40 management software (Code ) and with the OPEN sytem (Code ). PROGRAMMING A TRANSMITTER ON START Press button P2 (PCode) until LEDP turns ON. P2 RV3 CN L D4 LED 5 L D6 L E DP U2 U DIP CN4 T RV2 RV P2 F2 LEDP L E D LED2 LED3 L D 4 LED5 L D6 LED7 L D 8 L E D 9 LED 0 LED L D2 L E D 3 F P2 CN2 CN3 Give a START with the transmitter, using the button chosen for the start command. The LED will flash twice to confirm that the transmitter code has been memorized and will remain ON waiting for further transmitters. LEDP If no further code is memorized within 0 seconds, the LED automatically goes OFF and exits the programming procedure. ATTENTION: If the code entered is already in the memory, it will be deleted. LedP flashes 4 times to confirm this procedure. PROGRAMMING A TRANSMITTER ON PARTIAL START ) Press button P2 (PCode) until LEDP turns ON. 2) Press button (PTime). LEDP will start to flash quickly ) 2) P2 LEDP LEDP Give a START with the transmitter, using the button chosen for the start command. The LED will flash twice to confirm that the transmitter code has been memorized and will remain ON waiting for further transmitters. LEDP If no further code is memorized within 0 seconds, the LED automatically goes OFF and exits the programming procedure. ATTENTION: If the code entered is already in the memory, it will be deleted. LedP flashes 4 times to confirm this procedure. CANCELLATION OF ALL RADIO TRANSMITTERS Press and keep pressed button Pcode, ledp will start to flash. Wait until the ledp stops to flash and release the Pcode. LedP will flash 6 times to confirm the cancellation. 20

21 SAFETY LOOP CONNECTION DRAWING SHOWS HOW TO EVENTUALLY CONNECT THE MAGNETIC LOOP C + CN2 C2 - C = CONTACT OPEN C2 = CONTACT CLOSED 5 = 24 V = 0 V Security exit loop Connecting scheme of loop detector reader 0 = Contact photocell (n.c.) = Common photocell Loop Safety exit loop Security loop Connecting scheme of loop detector 2 reader 4 = Contact start (n.o.) = Common Loop2 Safety loop 2 Free exit loop 3 Loop3 Free exit loop Connecting scheme of loop detector reader 4 = Contact start (n.o.) = Common 2

22 SAFETY LOOP CONNECTION CONNECTING SCHEME OF THREE READERS OF MAGNETIC LOOP DETECTORS: (TWO OF THEM USED AS SECURITY DEVICE AND ONE AS FREE EXIT) SAFETY LOOP SYSTEM SAFE TY LO OP SAFETY LO OP EXIT LOOP SYSTEM SAF ET Y L O O P SAF ET Y L O O P EXIT LOOP 22

23 Advises TROUBLESHOOTING Make sure all Safety LED are turned ON All not-used N.C. contacts must have jumpers Problem Found Possibile Cause Solutions Motor doesn't respond to any START command a) Jumper missing on one of the N.C. Contacts b) Receiver doesn t work (LED 3 in not turned ON) c) Burnt fuse d) The Auxiliary contact is set as a N. C. Conntact a) Check Connections or Jumpers on Contacts 9/ - 0/ on the Cn2 and 2/6 on Cn b) Check connection, polarity and fuse of the receiver c) Replace burnt fuse on the Board d) Set the Auxiliary contact as a N.O. setting Dip Switches 3 in ON position Gate doesn't move while the motor is running a) The Motor is in the Released position b) The electronic / mechanic Clutch or By-pass Valve are not set c) There is an obstacle or the motor has reached a limit switch a) Re-lock the motor b) Adjust Electronic clutch using Trimmer Rv or Motor Clutch / Bypass Valve c) Remove obstacle or switch the the operating direction using Dip Switch 2 Gate doesn't reach the complete Open / Closed position a) Wrong setting of the Limit Switches b) Erron on Programming (page 0) c) Gate is stopped by an obstacle d) The fitting Geometry is inadequate a) Set Limit Switches b) Repeat Programming as on page 0 c) Remove obstacle d) Check fitting geometry following the operator installation manual The gate opens but doesn't close a) The photocell Contacts 9/ and 0/ are not closed b) The auxiliary contac is set as a N.C. a) Check LED or jumpers b) Set the Auxiliary contact as a N.O. setting Dip Switch 3 in ON The gate doesn't close automatically a) The Automatic Closing is OFF b) Pause time set to High a) Activate Automatic Closing by Dip Switch 6 b) Adjust Pause time using Trimmer Rv3 P.N. Every time an adjustment is made reset the board turning OFF the power for 0 seconds and then turn it back ON. 23

24 SALES CONDITIONS and WARRANTY GENERAL WARNING: Installation must be realized using parts and accessories approved by SEA. SEA is not responsible for incorrect installations and/or non-compliance with safety standards according to the law in-force. SEA is in no way liable for any damages and/or malfunctioning due to using parts and accessories non-compliant with the UL325 safety standards. ORDERS: Orders are processed upon approval by SEA. Buyers must confirm orders by sending a written Purchase Orders to SEA. Purchase Orders are intended as confirmation of orders and binding for the buyer, which accepts SEA sales condition. QUOTATION: Quotation and special offers with a non-specified duration expires automatically after 30 days. PRICES: Prices are based on the Price List in force. Discounts and quotation from Sales Rep. and other selling branches must be approved by SEA. Prices are F.O.B SEA Warehouse in Miami and do not include shipments costs. SEA reserves the right to modify the price list at any time and provide notice to its sales network. PAYMENT: Method of payments and terms are notified by SEA and displayed on the commercial invoice. DELIVERY: The delivery time on the invoice is not binding and represents an estimated delivery. Shipments costs will be charged to the buyer and SEA is not responsible for delays and/or damages occurred to the products during shipment. COMPLAINS: Complains and/or claims must be notified to SEA within 7 business days after receiving the products. Claims and complains must be supported by original documents. Customer must contact the factory for instructions and authorization. Merchandise returned for credit must be current, uninstalled and unused and returned in its original packaging. Freight must be pre-paid on all authorized returns. REPAIRS: Repairs and parts are subject to the availability in stock. Shipment of products for repairs must be pre-paid by the customer. Products shipped without authorization, sender s details and description of the problems will be refused. Customers must contact SEA for instructions. WARRANTY: for the original buyer only: Hydraulic and oil-bath motors: 36 months warranty from the date of invoice on manufacturing, assembling and workmanship defects. Electro-mechanic motors and electronic control systems: 24 months warranty from the date of invoice on manufacturing, assembling and workmanship defects. Lepus and Full Tank Standard model: 60 months warranty from the date of invoice on manufacturing, assembling and workmanship defects. No warranty will be recognized for damages due to incorrect installation and/or improper use for which the product was intended. SEA warranty obligations shall be limited to repair or replace the defective product/parts at SEA option, upon examination of the products by SEA technical Staff. All replaced parts must remain property of SEA. The warranty status of the product remains an unquestionable assessment of SEA. Buyer must ship pre-paid defective products. Products under warranty will be returned pre-paid by SEA. Recognized defects, whatever their nature, will not produce any responsibility and/or damage claims to SEA USA Inc and SEA s.r.l. Warranty shall not cover any required labor activities. Warranty will in no case be recognized if alterations and any other changes will be found on products. Warranty will not cover damages caused by carriers, expendable materials and faults due to improper use with the products specifications. No indemnities are recognized during repairing and/or replacing of the products under warranty. SEA USA Inc. and SEA s.r.l. decline any responsibility for damages to person and objects deriving from non-compliance with safety standards, installation instructions or use of the products sold. It is intended that warranty will be recognized only on products bought through the SEA authorized network. Products must be installed by professionals. No warranty will be recognized if products are installed directly by the final user. Warranty does not apply in case of unexpected events such as fire, flood, electrical power surge, lightning, vandalism and others. SEA USA Inc. is not responsible for errors in technical information printed in catalogs and installation manuals (800) sales@reliablegateopeners.com

Tel Fax: Toll free:

Tel Fax: Toll free: ELECTRONIC CONTROL UNIT (cod. 2302B Series) for swing gates automation (Mini Tank Series) C5 Accessories power supply: 24V dc Max 200 ma T1 Trimmer regulation: Operating times Open pause time Leaf delay

More information

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual Q45 230V ac Control panel for electric rolling shutters 230Vac Built-in radio receiver 433Mhz Adjustable pause time for automatic closing function

More information

Control Panel for Swing Gates. Model: CP-12 / January 2007

Control Panel for Swing Gates. Model: CP-12 / January 2007 Control Panel for Swing Gates Model: CP-12 / January 2007 INDEX Page 1- INTRODUCTION 3 1.1 1.2 Electrical and mechanical specification General Features 2- INSTALLATION AND SETUP 2.1.1 Installation of actuator

More information

PC170 Control Box USER MANUAL 24V DC GEAR MOTOR FOR RESIDENTIAL

PC170 Control Box USER MANUAL 24V DC GEAR MOTOR FOR RESIDENTIAL PC170 Control Box 24V DC GEAR MOTOR FOR RESIDENTIAL USER MANUAL INDEX 1. CONTROL BOX 2. SETTING 2.1 SW1 DIP SWITCH SETTING 2.1.1 SLOWDOWN ADJUSTMENT (DIP 1. SLOW) 2.1.2 OVER-CURRENT ADJUSTMENT (DIP 2.OVER

More information

Control board for electromechanical gearmotors HERMES

Control board for electromechanical gearmotors HERMES Control board for electromechanical gearmotors HERMES 1 Attention! The present user manual is designed for personnel skilled in installation, not for the final user; the electrician is then due to inform

More information

425D. Control Panel. Instructions. (800)

425D. Control Panel. Instructions. (800) 425D Control Panel Instructions Figure 13. Wiring detail of the 412 operator to the 425D Connecting the Operator(s) If your gate system has one operator, connect the black and white wires from your operator

More information

G2M Control Board Installation and Operations Manual

G2M Control Board Installation and Operations Manual BYAN SYSTEM, INC. 413 LINDEN LUSK, WY 82225 (800) 223-2926 G2M Control Board Installation and Operations Manual Specifications Power supply Motor Power Consumption Electric Lock Output Accessory Power

More information

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-MON UNIVERSAL SAFETY PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales

More information

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL325-2016 MONITORED DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com Technical Support:

More information

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Applications CRM includes a control relay box and a power supply; additional

More information

MAN-652-OM1. 3 Oct 07 Revision G.R. G.A. 2 Jun 06 Revision A.G. G.A. 1 Feb 06 Revision A.G. G.A. Rev. Date DESCRIPTION Prepared Approved

MAN-652-OM1. 3 Oct 07 Revision G.R. G.A. 2 Jun 06 Revision A.G. G.A. 1 Feb 06 Revision A.G. G.A. Rev. Date DESCRIPTION Prepared Approved MAN-652-OM1 3 Oct 07 Revision G.R. G.A. 2 Jun 06 Revision A.G. G.A. 1 Feb 06 Revision A.G. G.A. 0 Sept 2005 First Issue A.G. G.A. Rev. Date DESCRIPTION Prepared Approved Note: Biffi Italia has taken every

More information

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216

More information

AUS X CONTROL UNIT... 4 OPERATING MODES DESCRIPTION AUTOMATIC... 4 MANUAL... 5 CONNECTION OF EXTERNAL CONTACTORS K1 and K2...

AUS X CONTROL UNIT... 4 OPERATING MODES DESCRIPTION AUTOMATIC... 4 MANUAL... 5 CONNECTION OF EXTERNAL CONTACTORS K1 and K2... INDEX AUS X CONTROL UNIT... 4 OPERATING MODES DESCRIPTION... 4 AUTOMATIC... 4 MANUAL... 5 CONNECTION OF EXTERNAL CONTACTORS K1 and K2... 5 CONNECTON EXAMPLES... 6 CONNECTION OF AUS X WITH 2 COUPLES OF

More information

Technology Security Low consumption

Technology Security Low consumption Control units Technology Security Low consumption TECHNOLOGICAL SOLUTIONS FOR SECURE OPERATION All the latest generation V2 control units can be configured via smartphone and tablet, with V2AppTool. The

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual Carefree-Security Heavy Duty Commercial - Industrial Fully Sealed Digital Access Keypad Specially Designed for Gate Operators, Overhead Doors, Specialty Doors & Electric Door Locking Devices SINGLE OR

More information

MC61BR USER/INSTALLER MANUAL. v1.0 REV. 05/2018 LAMP MOT LOCK

MC61BR USER/INSTALLER MANUAL. v1.0 REV. 05/2018 LAMP MOT LOCK MC61BR USER/INSTALLER MANUAL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 LAMP MOT LOCK V+ FAP FCH PUL BL DS v1.0 REV. 05/2018 00. CONTT INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. CONNECTIONS

More information

CB17 CONTROL SYSTEM USER MANUAL

CB17 CONTROL SYSTEM USER MANUAL CB1 CTROL SYSTEM USER MANUAL INDEX 1. CTROL BOX 2. CB1 CTORL PANEL LAYOUT AND WIRE CNECTI INDICATI 3. SYSTEM SET UP PROCEDURE 3.1 TRANSMITTER MEMORIZINGAND ERASING PROCESS 3.2 SYSTEM LEARNING PROCESS 3.3

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 MONITORED DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884

More information

CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 1 / SEAV LRS 2102 R ++ SET

CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 1 / SEAV LRS 2102 R ++ SET CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 1 / SEAV LRS 2102 R ++ SET 230 Volt Single Phase logic control panel for single motor only sliding gate, roller garage door, single leaf swing gate Integral

More information

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ ) e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ 18990-04) Table of Contents Introduction... 1 e-fob Operation and

More information

Resolver to Digital Expansion Board

Resolver to Digital Expansion Board Resolver to Digital Expansion Board Catalog No. EXB009A01 Installation and Operating Manual 6/98 MN1313 Table of Contents Section 1 General Information............................. 1-1 Introduction....................................

More information

CENTRALE DI COMANDO ANALOGICA

CENTRALE DI COMANDO ANALOGICA V2 S.p.A. Corso Principi di Piemonte, 65/67 12035 RACCONIGI (CN) ITALY tel. +39.0172.812411 - fax +39.0172.84050 info@gatestore.co.uk www.remotecontrolgates.co.uk Easy3-4 IL n. 207 EDIZ. 20/10/2010 I GB

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Eclipse MCi. Variable Speed Drive Controller with Eclipse Operating System (EOS) 3rd Edition. VSD kits suitable for motors ranging from 0.4 to 2.

Eclipse MCi. Variable Speed Drive Controller with Eclipse Operating System (EOS) 3rd Edition. VSD kits suitable for motors ranging from 0.4 to 2. 3rd Edition Variable Speed Drive Controller with Eclipse Operating System (EOS) Eclipse MCi VSD kits suitable for motors ranging from 0.4 to 2.2 kw www.elsema.com Controller with Eclipse Operating System

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS READ THIS MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS PRODUCT FEATURES MODELS: IIA SPRINT 310/510/710 200/250 2000 SERIES 3000 SERIES

More information

COMMONLY USED 5.AFETY SENSORS. Photocell (Reflector) CLOSING Direction. Photocell (Reflector) CLOSING Direction OA4RO E.3IC-RIOIC4 EA4X IRB-RET

COMMONLY USED 5.AFETY SENSORS. Photocell (Reflector) CLOSING Direction. Photocell (Reflector) CLOSING Direction OA4RO E.3IC-RIOIC4 EA4X IRB-RET MLY USED 5.AFETY SENSORS 0----- OA4RO E.IC-RIOIC4 Direction. Set switch to "LIGHT ". Wire V power to photocell. Wire to photocell N0 Wire to photocell C- 4. Align photocell to reflector 5. Adjust sensitivity

More information

Profibus DP Expansion Board

Profibus DP Expansion Board Profibus DP Expansion Board Catalog No. EXB014A01 Installation and Operating Manual 8/03 MN1323 Table of Contents Section 1 General Information................................... 1-1 Introduction.........................................

More information

2-Way Wireless I/O Expander Installation Guide

2-Way Wireless I/O Expander Installation Guide 2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. Digital Lighting Systems, Inc. Four Channel Dry Contacts Relays Switch Pack DMX512 compatible USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION The is a 4-channel DMX-512 compatible electro-mechanical

More information

Universal Safety Photo Eye UL MONITORED DEVICE

Universal Safety Photo Eye UL MONITORED DEVICE IRB-MON Universal Safety Photo Eye UL325-2016 MONITORED DEVICE Operating Instructions CAUTIONS AND WARNINGS This product is an accessory or part of a system. Always read and follow the manufacturer s instructions

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

RB24 Relay Box Installation Guide For use in low voltage motorized window and skylight systems

RB24 Relay Box Installation Guide For use in low voltage motorized window and skylight systems RB24 Relay Box for 24 VDC motors part # 40995J Wire access ports Applications A Relay Box acts as an interface between FFI actuators and Direct Digital Control (DDC) systems such as Building Automation

More information

ELECTRONIC CONTROL PANEL ONE THREE-PHASE MOTOR QK-CE220RLINV

ELECTRONIC CONTROL PANEL ONE THREE-PHASE MOTOR QK-CE220RLINV INSTALLER TECHNICAL MANUAL ELECTRONIC CONTROL PANEL ONE THREE-PHASE MOTOR QK-CE220RLINV Attention!! Read this manual carefully before starting the installation. N.B. - QUIKO does not accept any responsibility

More information

Elapsed Timer Control Panel

Elapsed Timer Control Panel Installation Manual V6.2 Elapsed Timer Control Panel Current as of August 2017 The Sapling Company, Inc. Elapsed Timer Control Panel Table of Contents Table of Contents 2 Important Safety Instructions

More information

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina Progressive Industries Warranty Progressive warrants its products are free from defects in materials and workmanship for a period of three years. This is in lieu of all other warranties, obligations, or

More information

Remote Control Electrical Roller Blinds

Remote Control Electrical Roller Blinds Remote Control Electrical Roller Blinds Instruction Manual for Model HT200 Contents 1. Description of Remote Control Electrical Roller Blind General Information Technical Data 2. Parts List Model HT200

More information

Please keep these instructions for further reference.

Please keep these instructions for further reference. C 4 / C 5 GB Instructions for Initial Operation and Wiring Scheme Manual Door Operator for Industrial Use Please keep these instructions for further reference. . Contents Chapter Page. Contents. Meaning

More information

MC61PL USER/INSTALLER MANUAL MC61-PL-3.6

MC61PL USER/INSTALLER MANUAL MC61-PL-3.6 MC61PL USER/INSTALLER MANUAL MC61-PL-3.6 00. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW ATTTION: This product is certified in accordance with European Community (EC) safety standards. This product complies

More information

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions BlueGuard FE Bluetooth Enabled Access Control MODEL BG-FE Operating Instructions CAUTION AND SAFETY INFORMATION IMPORTANT: If the equipment is used in a manner not specified in this manual, the protection

More information

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL INSTRUCTION MANUAL IM253 R0 AquaStart COMBINATION SOFT STARTERS START-UP MANUAL INDEX Power Connections...3 Basic Wiring...4 Start-Up By Voltage Ramp...5 Local / Remote Modes...6 Control and Signal Connections...6

More information

Install Motor Controller User Manual

Install Motor Controller User Manual Property of Motion Laboratories, Inc. Install Motor Controller User Manual 2014 Motion Laboratories, Inc. Created By: Michael Shaw Approved By: John Coppolecchia Page: 1 Page: 2 2014 Motion Laboratories,

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS TM CarSense 303-L OPERATING INSTRUCTIONS LOGIC INTERFACE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com Technical Support: technical@emxinc.com

More information

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL Operating Instructions KEYPAD Compatible WIRELESS ACCESS CONTROL Contents Technical specifications page 1 Approvals page 1 Changing the Master code page 2 Adding a User code page 3 Deleting a User code

More information

LOGIC BOARD (L4) REPLACEMENT KIT K1A6837 INSTALLATION REMOVE EXISTING BOARD INSTALL NEW BOARD WIRING POWER AND CONNECTION SETTINGS

LOGIC BOARD (L4) REPLACEMENT KIT K1A6837 INSTALLATION REMOVE EXISTING BOARD INSTALL NEW BOARD WIRING POWER AND CONNECTION SETTINGS LOGIC BOARD (L4) REPLACEMENT KIT K1A6837 INSTALLATION APPLICATION REQUIREMENTS: Available to all commercial door operators using the Logic 4 control board. To avoid SERIOUS personal INJURY or DEATH from

More information

High Pressure E/P Regulator. ITVH Series

High Pressure E/P Regulator. ITVH Series Doc. No. DIQ-69200-OM002-A P R O D U C T N A M E High Pressure E/P Regulator MODEL/ Series/ Product Number ITVH Series Install and operate the product only after reading the Operation Manual carefully

More information

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting

More information

Series 803 LED Product Price Display

Series 803 LED Product Price Display Series 803 LED Product Price Display May 2007 Rev. 1.1 1 Installation and Operation Manual Table of contents 1. Safety.......3 2. Series 803 sign features.......4 2.1 Sign descriptions........4 2.2 Control

More information

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System User s Manual D-M-E Company D-M-E Company MFA-0801 & MFA-1201 Page 1 Copyright D-M-E Company 1995. All rights reserved. D-M-E

More information

8000 Series: Installation Supplement R2-1-12

8000 Series: Installation Supplement R2-1-12 8000 Series: Installation Supplement R2-1-12 Smartscan Incorporated, 33083 Eight Mile Road, Livonia MI 48152 Tel: (248) 477-2900 Fax: (248) 477-7453 Web: www.smartscaninc.com SMARTSCAN INCORPORATED Livonia,

More information

EWCH 485 Electronic Pulse Counter

EWCH 485 Electronic Pulse Counter Electronic Pulse Counter Technical Data Sheet INSTRUMENT DESCRIPTION GENERAL DESCRIPTION is a programmable microprocessor based counter with 1or 2 outputs. The instrument offers the possibility to program:

More information

Number of input channels

Number of input channels Safety Relay Unit (Sensor Connector Type) CSM DS_E_3_1 Less Wiring Required with Safety Light Curtain Sensor connector allows direct connection to OMRON 3SJ Safety Light Curtains with PNP outputs. Reduces

More information

LPG STM 94442A User s Manual

LPG STM 94442A User s Manual 1 LPG STM 94442A User s Manual This Manual belongs to: Company: 3 Table of Contents Features....... 4 Hardware Installation...5 Monitor Mounting Dimensions.....7 Monitor Specifications...8 Sender Specifications.....9

More information

Profibus DP Expansion Board

Profibus DP Expansion Board Profibus DP Expansion Board Catalog No. EXBD04 Installation and Operating Manual 10/02 MN1393 Table of Contents Section 1 General Information................................................... 1 1 Introduction.......................................................

More information

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285. SECTION 26 04 75 - SURGE PROTECTION DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Applicable provisions of the General Conditions, Supplementary General Conditions and Special Conditions shall govern work performed

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. , Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual

More information

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved. R & D SPECIALTIES 2004, by R & D Specialties, Inc. All Rights Reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written permission of R & D Specialties.

More information

Fast Safe Secure USER MANUAL. Sentinel Z18 Flap Barrier. For more Information: t: e:

Fast Safe Secure USER MANUAL. Sentinel Z18 Flap Barrier. For more Information: t: e: Fast Safe Secure USER MANUAL Sentinel Z18 Flap Barrier For more Information: t: +61 07 3205 1123 e: info@rotech.com.au www.rotech.com.au 6 Table of Contents Summary... 1. Technical Parameter... 2. Function

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-022 2017A-0330 4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System SYSTEM INSTALLATION INFORMATION Description The 4 Channel

More information

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS SECTION 264313 - TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

RELAY MODULE A/B INSTALLATION/USE INSTRUCTIONS

RELAY MODULE A/B INSTALLATION/USE INSTRUCTIONS RELAY MODULE 9974 INSTALLATION/USE INSTRUCTIONS All connections MUST be made with the electrical supply switched off and the batteries disconnected. GENERAL WARNINGS This manual is intended for technically

More information

Differential Liquid/Gas Pressure Transmitter

Differential Liquid/Gas Pressure Transmitter Installation Instruction Differential Liquid/Gas Pressure Transmitter Catalog Number(s) 1414-CPZ10FWFAA, 1414-IPZ10FWFAA Explosion Hazard WARNING Do not use in an explosive or hazardous environment, with

More information

Tempco Instruction Manual

Tempco Instruction Manual Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed

More information

VG-305A AC Traffic Light Controller Kit

VG-305A AC Traffic Light Controller Kit Galak Electronics Electronic kits and components Website: GalakElectronics.com Email: sales@galakelectronics.com Phone: (302) 832-1978 VG-305A AC Traffic Light Controller Kit Thank you for your purchase

More information

212iL Rev. 1.1

212iL Rev. 1.1 212iL 1 International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iL (illuminated Luxury) Keypad Single Unit Keypad- Control Installation Manual Features: 120 User Capability Illuminated

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

Ellard Product Instructions

Ellard Product Instructions Ellard Product Instructions Motor Controller - V3D Maxi Stock Code Description Roundthorne Ind Est Floats Road Wythenshawe Manchester M23 9WB Tel: +44 (0) 161 945 4561 Fax: +44 (0) 161 945 4566 Iss: 1

More information

LA600WH WIRED / WIRELESS DOOR CHIME

LA600WH WIRED / WIRELESS DOOR CHIME LA600WH WIRED / WIRELESS DOOR CHIME To register this product, visit: www.nutone.com THIS PACKAGE INCLUDES: Wired / Wireless Door Chime with MP3 upload capability Decorative White Chime Cover USB Cable

More information

Operating Instructions MAGNETIC High Door Pedestrian Barrier Type MPH 112

Operating Instructions MAGNETIC High Door Pedestrian Barrier Type MPH 112 Operating Instructions MAGNETIC High Door Pedestrian Barrier Type MPH 112 58175005EN 01/2009 MPH-112 Page 1/96 Table of contents 1. Safety... 5 1.1 General safety instructions... 5 1.2 Proper use... 5

More information

Wireless Key fob, Key pad & Receiver Range

Wireless Key fob, Key pad & Receiver Range Wireless Key fob, Key pad & Receiver Range 4Ch Wireless Receiver 4x Voltage Free relay outputs (NO + NC) 100m Transmission range Multiple user codes 2 Channel wireless control Clear hinge up lid 12V DC

More information

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual Series 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX MODEL: S/N: DATE: Notice! Although every effort has been made to insure that this manual is current and accurate as of date of publication, no guarantee

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

ELECTRONIC CONTROL PANEL FOR TWO 230VAC MOTORS TECHNICAL INSTALLATION MANUAL FOR AUTOMATIC GATES

ELECTRONIC CONTROL PANEL FOR TWO 230VAC MOTORS TECHNICAL INSTALLATION MANUAL FOR AUTOMATIC GATES ELECTRONIC CONTROL PANEL FOR TWO 230VAC MOTORS UNIK2E230 _ V2 (COMPLETE) UNIK2E230SK _ V2 (WITHOUT BOX AND TRANSFORMER) BOX IP 54 TECHNICAL INSTALLATION MANUAL FOR AUTOMATIC GATES WARNING! Before installing,

More information

SK-1011-SDQ Access Control Keypad. Manual

SK-1011-SDQ Access Control Keypad. Manual SK-1011-SDQ Access Control Keypad Manual Quick Installation Guide: This page is for installers looking to do a basic installation and programming of the keypad. For more in-depth installation and programming

More information

Installation Instructions

Installation Instructions Lucci Remote Fan Control Non Dimming SKU# 210019 Rated Voltage 240V~ 50Hz Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all instructions

More information

Seven Channel Remote Control

Seven Channel Remote Control Seven Channel Remote Control Page 1 Versa7 Kit Contents The Versa7 is designed to remotely control up to seven devices, or functions. All seven functions can be controlled with the supplied four button

More information

SLIMBAT2 wireless photocell MANUAL

SLIMBAT2 wireless photocell MANUAL v.1.1 1. of the device The wireless photocell is a safety element in gate automation. Between the transmitter and the receiver, the infrared beam is created, forming invisible to the human eye barrier.

More information

Digital Electronic Lock OWNER S MANUAL

Digital Electronic Lock OWNER S MANUAL CAL-ROYAL CR3000 Digital Electronic Lock OWNER S MANUAL THANK YOU for purchasing CAL-ROYAL CR 3000 Digital Lock. Your new CAL-ROYAL CR3000 Digital Lock advanced features include: 1 Master Code for entry

More information

Thalia L QRG (See also specific motor QRG)

Thalia L QRG (See also specific motor QRG) Thalia L QRG (See also specific motor QRG) Quick reference guides are not a replacement for the supplied instructions, they are supplementary Read and understand the installer warnings in the main instruction

More information

Manual Simatek Control Unit GFC 32

Manual Simatek Control Unit GFC 32 Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections

More information

Q80A. 230V ac. CONTROL PANEL FOR DOUBLE/SINGLE SWING GATES Instructions Manual. Multi-function control panel for double/single swing gate - 230Vac

Q80A. 230V ac. CONTROL PANEL FOR DOUBLE/SINGLE SWING GATES Instructions Manual. Multi-function control panel for double/single swing gate - 230Vac CONTROL PANEL FOR DOUBLE/SINGLE SWING GATES Instructions Manual Q80A 230V ac Multi-function control panel for double/single swing gate - 230Vac Programming display Electronic adjustment of each motor s

More information

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL 2 INTRODUCTION First and foremost we would like to thank you for purchasing this product. Our commitment to satisfying our customers can be seen

More information

Robus 600/1000. Programmable functions using the Oview programmer. STF ROBUS Rev00 Firmware: RF02

Robus 600/1000. Programmable functions using the Oview programmer. STF ROBUS Rev00 Firmware: RF02 Robus 600/1000 Programmable functions using the Oview programmer STF ROBUS 600-1000 Rev00 Firmware: RF02 COMMON FUNCTIONS name This parameter enables the user to assign the automation with a name other

More information

Please keep these instructions for further reference.

Please keep these instructions for further reference. Control 44/45 GB Instructions for Initial Operation and Wiring Scheme Manual Control Unit for Door Operators Industrial Use Please keep these instructions for further reference. . Contents Chapter Page.

More information

SP-C1 Mobile Docking Station Installation Guide

SP-C1 Mobile Docking Station Installation Guide SP-C1 Mobile Docking Station Installation Guide Box Contents After you unpack your SP-C1 Mobile Docking Station, make sure everything here is included: 1 x Docking Cradle 1 x Audio Cable 1 x Adhesive Mount

More information

MCR 808LX RELAY MANAGEMENT MODULE

MCR 808LX RELAY MANAGEMENT MODULE RELAY MANAGEMENT MODULE This installation manual has been written by the manufacturer and it is considered integrating part of this product. The information included are intended for the expert technicians

More information

Mold Control Systems, Inc.

Mold Control Systems, Inc. PH: 407-855-2899 FAX: 407-855-2855 Mold Control Systems, Inc. SITC-15 Temperature Controller GITC-15 Temperature Controller Mainframe Operation Manual SITC Quick Reference:... GITC Quick Reference:...

More information

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation. Product No. 99-600-91 Rev. B Page 1 of 8 MCG Surge Protection Model 160MXT Installation Instructions Important Warranty Information MCG surge protectors are designed to work at specific voltages and configurations,

More information

SK-1011-SQ Digital Access Keypad with 5A Relay Output

SK-1011-SQ Digital Access Keypad with 5A Relay Output User Operation for the SK--SQ. Using the User Codes: A. User codes operate the door (4-8 digits long). Press u u u u B. The key must also be pressed if the keypad is in manual-entry mode. Press u u u u

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual Manual NanoTron Dual Timer Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com

More information

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX MICRO GROW GREENHOUSE SYSTEMS, INC 4065 ZEVO DR., SUITE B-, TEMECULA, CA 9590 PHONE (95)-96-3340 FAX (95)-96-3350 Growstat Series VENTSTAT GENERAL INSTALLATION PROCEDURES PANEL MOUNTING Mount the control

More information

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...

More information

EM-F-7G Safety Extension Module

EM-F-7G Safety Extension Module EM-F-7G Safety Extension Module One-channel control with four safety output channels Features Safety Extension Module provides additional safety outputs for a Primary Safety Device (for example, an E-stop

More information

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN

More information

UPS READY POWER DISTRIBUTION ASSEMBLY

UPS READY POWER DISTRIBUTION ASSEMBLY UPS READY POWER DISTRIBUTION ASSEMBLY FOR TRAFFIC CABINETS with LED Signals INSTALLATION & OPERATOR S MANUAL VERSION 1.2 1 Note The instructions contained in this manual are not intended to cover all of

More information