TruPortal System Controller Quick Reference (for TP-SYS-BRD, TP-SYS-2D, TP-SYS-2D-E, TP-SYS-2D2R) en-us
|
|
- Jodie Cunningham
- 6 years ago
- Views:
Transcription
1 TruPortal System ontroller Quick Reference (for TP-SYS-BR, TP-SYS-, TP-SYS--E, TP-SYS-R) en-us The TruPortal System ontroller The TruPortal System ontroller provides a solution for access control. It consists of two boards; the I/O board and the system on module (SOM) board. The I/O board, the larger of the two, contains the power supply and all field wiring connections. The SOM, the smaller mounted board, contains the main PU and memory. The event log buffer and the real time clock are stored in battery-backed memory. Each reader port can accommodate a reader that utilizes Wiegand ata/ata0, LE control, and buzzer control. Twelve supervised inputs (excluding tamper and power monitor) are provided for door sense, reader tamper, or request to exit as well as four auxiliary supervised inputs. TP-SYS-: TruPortal -oor base kit. onsists of a TruPortal System ontroller, installed in UL-listed enclosure with amp power supply. TP-SYS-R: TruPortal -oor base kit with readers. onsists of a TruPortal System ontroller, installed in UL-listed enclosure with amp power supply. Includes T-00 Readers (quantity = ) and redentials (quantity = 5). TP-SYS--E: TruPortal -oor base kit for EMEA. onsists of a TruPortal System ontroller, installed in E-compliant enclosure with amp power supply. -E Part number suffix for panel with E enclosure (E 0 VA internal transformer). ot evaluated by UL. Interfaces The TruPortal System ontroller interfaces upstream with the browserbased TruPortal User Interface. There is no dedicated host software to install on operators workstations. The TruPortal System ontroller provides two () Ethernet ports. onfiguration data and event/status reports are exchanged with the user interface via the primary Ethernet ports. The secondary port is not used. ommunication via modem is not supported. Packing List TruPortal System ontroller PB assembly, which consists of the I/O board and the SOM (quantity = ) Two positional terminal plug-in block (quantity = 7) Three positional terminal plug-in block (quantity = 0) Four positional terminal plug-in block (quantity = 8) End of line resistors k ohm, % (quantity = ) Push-fit terminal tab adapters (quantity = ) Battery cable (quantity =) Battery bracket (quantity = ) Screws for battery bracket (quantity = ) Strain relief for power cable (quantity = ) Terminal block cover (quantity = ) Lock (quantity = ) Machine screws for securing the cover (quantity =6) Enclosure (depending on option ordered) Transformer (depending on option ordered) redentials (depending on option ordered) T-00 Proximity Readers (depending on option ordered) Model umbers The panels are available in the following configurations: TP-SYS-BR: TruPortal System ontroller. Board only. apable of controlling two () doors. o enclosure or readers. TruPortal System ontroller Quick Reference P/ B JA en-us
2 System apacities Attribute TP-SYS Attribute TP-SYS umber of persons 0,000 umber of unique credentials 0,000 redentials per person 5 Access levels 6 Access levels per credential 8 Schedules 6 Time intervals per schedule 6 Holiday groups per schedule 8 Holiday groups 8 Holidays per holiday group Holidays (total) 55 Areas 6 Reader groups 6 Operator roles User-defined fields 0 Video layouts 6 ard formats 8 umber of retained events in event log 65,000 oors/readers umber of doors (base board and dual door controllers) with readers in / umber of doors with readers in and out TP-A--BR ual oor ontrol Modules (including built in) 6 / Readers (total) 6 Inputs/Outputs Total number of system inputs (including TruPortal System ontroller) Total number of system outputs (including TruPortal System ontroller) Total number of TP-A-IO or TP- A-IO-BR Input/Output Expansion Add-Ons VR/ameras VRs 66 8 ameras per VR TVR0 (EMEA & US) TVR0 (US Only) 6 ameras (maximum) 6 Ethernet ports (total/supported) / RS-85 SAPP bus ports Anti-attack Bushing ap An anti-attack bushing cap covers a rear tamper spring. It fits inside an O-ring bushing located in the cabinet s rear wall anti-tamper spring knockout. Leave the O-ring bushing and cap in place if the rear tamper is not used. If the rear tamper is used:. Remove the cap and the O-ring with the edge of a flat screwdriver.. iscard the O-ring.. Align the cap for the tamper spring and knockout hole on the cabinet back.. Screw the cap into the mounting surface. 5. Place the control cabinet over it, allowing the rear tamper spring to fit inside the cap. The cap will fit into the cabinet s tamper spring knockout hole. 6. Secure the cabinet to the mounting surface. Mounting the Module On dry wall, use /8 in. (.75 mm) hollow wall, expansion anchors. Unscrew the screws from the anchors. Mark the mounting holes. Force a starter hole in each mark with a sharp tool. Hammer the anchors into each hole. Align the box mounting holes over the anchor holes and screw in the anchors until tight. On a concrete surface, hold the control box on the mounting surface. Mark the mounting holes. Use a hammer drill with a /6 in. (.76 mm) carballoy drill bit and make in. (5. mm) deep holes in each marking. Insert a # 6-8 plastic anchor in each hole and hammer them in. Use # 8 X in.(5. mm), Phillips, wood screws to screw into the plastic anchors and mount the box. See Figure on page 9. ommunication Wiring The controller communicates to the user interface via Ethernet. The downstream communication ports are -wire RS-85 interfaces which can be used to connect additional I/O panels. The interface allows multidrop communication on a single bus of up to 000 feet (00 m). Use twisted pairs (minimum AWG / 0.6 mm / 0.6 mm ) with an overall shield for communication. See Figure on page 0. Reader Wiring Each reader port supports Wiegand ata/ata0. Voltage at the reader port is passed through from the input voltage of the controller and is limited to 50 ma. The reader supply voltage is V. Readers that require different voltage should be powered separately. These readers may be connected and TruPortal System ontroller Quick Reference P/ B 6JA en-us
3 powered through the dual door interface module. Refer to the reader manufacturer specifications for cabling requirements BZ + GR R 0 0 Reader wiring 0/7 /8 allout escription allout escription Buzzer LE + V Buzzer Green LE 5 ata0 Red LE 6 ata 5 7 ata ata0 7 0 V 9 Buzzer 8 0 LE 9 0 Power allout escription allout escription Buzzer 5 ata + V 6 ata0 Green LE 7 Ground Red LE Wiring In and Out readers 0/7 /8 /9 BZ GR R 0 0 A B Reader (Out) Ground Ground Reader (In) Power Input ircuit Wiring Typically, these inputs are used to monitor door position, request to exit, or alarm contacts. Input circuits are supervised. The input circuit is able to report a condition of Fault for the status of the circuit, which appears as a Tamper event for supervised conditions. A supervised input circuit requires a resistor be added to the circuit to facilitate proper reporting. The standard supervised circuit requires ohm, % resistors and should be located as close to the sensor as possible Relay ircuit Wiring All relays are dry contact. 0 9 Output 0 V rating Siren relay A Strobe relay A Strike relay 5 A 5 Aux relay A 6 The relays for siren and door strike have a ommon pole (), a ormally losed pole (), and a ormally Open pole (O). When you are controlling the delivery of power to the door strike, the ormally Open and ommon poles are used. When you are momentarily removing power to unlock the door, as with a mag lock, the ormally losed and ommon poles are used. heck with local building codes for proper egress door installation. Power The TruPortal System ontroller requires 8 VA or V for input power at, or V at ( V and V input power were not evaluated by UL). When powering the board from V, the onboard battery charger will not be used and the lead-acid backup battery TruPortal System ontroller Quick Reference P/ B JA en-us
4 should not be connected to the TP-SYS. The power supply providing the V must have its own backup source. wires. The earth ground connection at Pin is not required if the controller board is grounded through the mounting screws. Maximum lengths for wiring TP-SYS 0/0 VA Power wiring diagram I/O escription onnection Maximum length of AWG wire (in feet) Maximum line resistance (in Ohms). V supply output approximately.8 allout escription allout escription Ground stud onnections for A wiring Red transformer wires Wiring indication Supervised inputs approximately 8 Power connectors + 0 V 5 V relay output (assume 5% voltage drop) 7- (O) 7- () 7- () - (O) - () - () 5 approximately 0.7 allout escription allout escription V input 8 V Input VA Input A A V relay output (assume 5% voltage drop) - () - () - (O) 5-() 5- () - (O) - () 0- (O) 0- () 0 approximately.6 The maximum input current is.7 A. The gauge is dependent on the length of the wire. The TruPortal System ontroller can be powered by an internal 8 VA transformer that uses 0 AWG (0.8 mm / 0.58 mm ) secondary ote: These specified ranges have been verified by UL. ote that if you run a longer wire, it is not verified by UL. This equipment must be permanently connected to a mains fused spur ( A or 5 A) using -core cable with each core being no less than 8 AWG (.0 mm / 0.8 mm ). The mains cable should be clamped securely with the cable clamps provided within the equipment/installation kit. Knockouts are provided on the top, bottom and sides of this equipment and these are intended for conduit or cable glands. As a mains switch is not provided on the equipment, a readily accessible disconnect device shall be incorporated in the building installation wiring. Where there is doubt as to the phase of this wiring, the device, when operated, will disconnect both poles simultaneously. TruPortal System ontroller Quick Reference P/ B 6JA en-us
5 Mains Supply Item Internal transformer Input current rating (A) orth America product 0 VA +0% -5%, 60Hz European product 0 VA +0% -5%, 50Hz Australian/ ew Zealand product 0 VA ±0%, 50Hz 600 ma 50 ma 50 ma Power Setup Power management parameters for the TruPortal System ontroller are preconfigured as follows. These parameters can not be changed: Brownout mode: Alarm and report Brownout voltage (V): 0.00 Battery size (Ah): 8 Select heck for battery. lear the Enable battery tests check box. Test time: 0 sec Mains fuse T60 ma 50 V, UL Listed T00 ma 50 V T00 ma 50 V Low load test period: min High load test period: 0 hr Low voltage (V):.70 Warning: For continued protection against risk of fire, replace the mains fuse only with the same type and rating of fuse. The Aux. supply output is a lass Power Limited circuit. Warning voltage (V):.0 utoff voltage (V): 0.0 Very low voltage (V): 9.00 Excess charge voltage (V): 6.00 Aux Supply Item Output voltage () Standby battery Maximum recharge time power supply rating** Battery charge limit Quiescent current Mains powered unit + V input* + V input* V ±5% V ±5% V ±5% 7 Ah or 8 Ah 7 Ah or 8 Ah hours hours. A. A. A. A. A 0 ma 0 ma 00 ma * V and V input were not evaluated by UL. ** This Power Supply Rating is for all the current requirements, including recharging the battery. Board protection is provided by resettable fuses which are not replaceable. All wiring in this enclosure is required to be UL compliant. All installation wiring within this equipment cabinet should utilize plastic cable ties to bundle cables and attach to designated cabinet cable mounting locations to provide strain relief for the cable harness. isposal of batteries should be according to the local laws and regulations of your region. ontact your local waste management office for information on battery recycling or disposal. If you are not able to identify the applicable rules in your area, check the instructions which will be available from the battery manufacturer. Ground all enclosures in accordance with FPA 70 and anadian Electrical ode, Part I. utoff time: 0 sec o current (ma): 7 Excess power state discharge current (A):.00 onfiguration Use the TruPortal Installation Wizard to discover the controller and connected peripherals, and to change basic configuration parameters.. Insert the TruPortal disc in your computer s /V drive (Windows only).. Install Microsoft.ET.0 Framework. The TruPortal Utilities software will detect automatically if the.et software is installed and display the word Installed next to the link if it is found.. Install Bonjour Print Services. The TruPortal Utilities software will detect automatically if the Bonjour software is installed and display the word Installed next to the link if it is found.. lick iscovery and Installation Wizard. 5. Select a Language and click [ext]. The wizard will search the network for all TP controllers. 6. Select the controller to configure from the list and click [ext]. 7. Type the Administrator s current Password. The default administrator User ame is admin The default administrator Password is demo 8. hoose a new password for the administrator. The Administrator account has access to all aspects of the TP controller configuration. Leaving default user names and passwords in place is dangerous. Anyone familiar with the product will know the defaults. 9. Type the password in the ew Password and onfirm Password fields and click [ext]. 0. hange the settings on the etwork onfiguration tab as directed by the site s network administrator. TruPortal System ontroller Quick Reference 5 P/ B JA en-us
6 . lick [ext]. The wizard will discover controllers and I/O expansion modules connected to the TP controller.. lick [Sync with P] to set the correct time on the controller.. Select the appropriate Global Input EOL Terminations to indicate how the tamper circuits and sensors on the doors and readers are wired.. For each general purpose auxiliary input that is connected: a. Select a Mode. b. Observe the inputs to determine they are working and communicating with the controller. 5. For each general purpose auxiliary output that is connected: a. lick the icon next to the State to change state. b. Observe the outputs to determine they are working and being activated by the controller. 6. For each door controller, select the umber of oors controlled. 7. For each door: a. Select the appropriate Mode for contact, request to exit and tamper circuits. b. Select commands from the oor ontrol list to test each door for proper installation and electrical wiring. 8. When you have tested all devices, click [Finish]. Jumpers Status LEs The following chart describes the purpose of each LE on the I/O board. I/O board LE LEs and LE LE LE 5 LE 6 escription uring normal operation, the heartbeat is indicated by a one second blink rate on LE. uring firmware upgrade: When LE and LE are both O, the board is in monitor program mode (bootloader mode). When LE is O and LE is off, programming (flash) firmware is in progress. Orange LE indicates communication occurring on SAPP port. Orange LE indicates communication occurring on SAPP port. Orange LE indicates communication occurring on SAPP port. Orange LE indicates communication occurring on SAPP port. Jumper escription LE 7 Green LE indicates link and activity on primary Ethernet port (Eth0). 7 External LE indication for power (to be wired to the outside of the enclosure) LE 8 Yellow LE indicates speed on primary Ethernet port (Eth0). 8 9 ontrols SAPP termination. 0-ohm termination is added across the bus when the shunt jumper is installed on the pin header. ontrols SAPP termination. 0-ohm termination is added across the bus when the shunt jumper is installed on the pin header. LE 9 LE 0 LE Green LE indicates link and activity on secondary Ethernet port (Eth). Yellow LE indicates speed on secondary Ethernet port (Eth). ot applicable 0 ontrols SAPP termination. 0-ohm termination is added across the bus when the shunt jumper is installed on the pin header. LE Green LE indicates the presence of power to the board at connector. 5 ontrols SAPP termination. 0-ohm termination is added across the bus when the shunt jumper is installed on the pin header. If the panel needs to be started on battery only, without ever having A or power, this connector should be momentarily shorted. LEs through 0 will be switched off when the enclosure is closed. The following chart describes the purpose of each LE on the SOM board. SOM board LE Power LE escription Green LE indicates SOM power. Status Status Yellow LE, along with the green power LE, indicates initialization. Red LE is off. urrently not defined. TruPortal System ontroller Quick Reference 6 P/ B 6JA en-us
7 TruPortal Reader Output LEs The following chart describes the behavior of TruPortal reader output based on different actions of the door. Reader Mode LE LE Mode RLE I O olor OFF olor O Time OFF Time Repeat ount Beep ount RdiLine RdiLine isabled /A Unlocked GREE GREE Locked RE GREE Facility /A /A RE RE ard Only RE RE Pin Only RE RE ard & Pin RE RE ard or Pin RE RE /A /A Replace Battery The event log buffer and the real time clock are backed up by a V battery. Without power being applied to the controller, the battery will retain events and transactions for up to one year. This battery should be replaced annually to insure that proper backup functionally is maintained. Remove the insulator from the battery holder after installation. Replacement battery: Panasonic R5 Lithium coin cell battery. Warning aution: When changing the lithium battery, replacement must be a Panasonic R5 only. Battery may explode if mistreated. o not recharge, disassemble or dispose of in fire. Follow local code for proper disposal of used lithium battery. Specifications The TruPortal System ontroller is for use with UL Listed access control power limited power supplies. These specifications are subject to change without notice. Primary Power: - A power: 8 VA ± 0% - power: / V ± 0% (ot evaluated by UL.) - Maximum input power:.7 A - Total current that can be sourced from panel: A. ote: It is up to the installer to ensure that the sum of the loads on all the supply outputs from the TruPortal System ontroller plus the current consumed by the controller is equal to or less than. A (see power table). The. A output current from the regulator also includes at least 00 ma to power the I/O board and the SOM. Maximum available output current is A. [Example: 50 ma for (Reader power) + 00 ma for (SAPP Ports) = 650 ma total current used.] rawing more will cause the output voltage to drop as the system regulator starts to current limit. - The power applied from the mains to the transformer in the enclosure is 0 VA for orth America (0 VA for Europe, and 0 VA for Australia). Memory and lock Backup: Panasonic V R5 Lithium coin cell battery Wiring - Ground: AWG (.68 mm /.08 mm ),, provided in the panel from the fused terminal block to the ground lug - Module Bus (RS-85) abling (device communication and power): Recommended: AWG (0.6 mm / 0.6 mm ), conductors, shielded twisted pair, 0 impedance, low capacitance, pf/meter or.5 pf/foot (such as Belden 98). - Maximum Length: Up to 000 feet (60 m) of cable on a Module bus port. ote: For longer cable distances, or where one cable connects many expansion modules (daisy chained, star wiring configurations are not acceptable), a 0-ohm terminating resistor will need to be installed across A and B communication terminals of the last module on the bus cable. - Separate Power (or door strike) Wiring: Recommended:8 AWG (.0 mm / 0.8 mm ), stranded and insulated ( conductors; color-coded is preferable) - Inputs/Sensor abling: AWG (0.6 mm / 0.6 mm ), wires (For electrically noisy environments, use twisted pair, and/or shielded cable.) - Outputs/Signaling: AWG (0.6 mm / 0.6 mm ), conductors Reader abling: AWG (0.6 mm / 0.6 mm ),(For anadian UL Listed installations: AWG / 0.6 mm / 0.6 mm ), shielded. Maximum for reader data lines: 500 feet (50 m). Maximum for power wiring: 00 feet (9. m). TruPortal System ontroller Quick Reference 7 P/ B JA en-us
8 - Basic reader (no LEs, buzzer control, or tamper): conductors - Reader with LEs: 6 conductors - Reader with LEs, plus buzzer and tamper: 9 conductors Relays outputs: - Siren relay, 0 V - Strobe relay, 0 V - Strike relay, 5 0 V - Aux relay, 0 V Environmental: Temperature: Operating: to 0 F (0 to +9 ) Storage: -0 to 85 F (-0 to 85 ) Humidity: 0 to 85% ± 5% RH BTU Output: 7.7 BTU/hour Mechanical: imensions: H 6.0 x W 9.8 x.65 inches (H 60 x W 50 x mm) Weight of I/O board and SOM board:.0 lbs. (0.7 kg) Weight of accompanying parts: Enclosure:. lbs. (6 kg) Transformer:. lbs ( kg) Battery retention bracket:0. lb. (0.09 kg) 8 Ahr battery:.8 lbs. (5.8 kg) UL9 Listed F Part 5 E marking RoHS compliant WEEE F part 5 UL Listed AES8 certified (ertificate #96) TruPortal System ontroller Quick Reference 8 P/ B 6JA en-us
9 0.00mm [0.9in] 6.8mm [0.55in] Figure : TruPortal System ontroller enclosure R.55mm [0.00in].00mm [0.in] 5mm ±0.5 [5.7in ±0.0] 50mm ± mm [.97in ±0.0] [.85in] 5.00mm [0.000in].9mm [8.86in] 7.mm [6.86in] 0.00mm [5.5in] 0.9mm (5 POS) [0.0in] K G K 0mm ±0.5 [5.in ±0.0] 59.08mm [.in] 00mm ±0.5 [.9in ±0.0] 65mm ±0.50 [.559in ±0.097] 89.0mm ±.0 [.50in ±0.09] 60.5mm [6.in] 9.8mm [5.90in] 0.00mm [.57in] 0.mm [0.0in] 8.00mm [.9in] K G 7.mm [.86in] 50mm ±0.50 [5.9in ±0.0] 5.00mm [0.59in] E H 55mm ±0.50 [.7in ±0.0] 60.6mm [.8in] 50mm ±0.50 [5.9in ±0.0] G 0mm ±0.5 [9.06in ±0.0] 65mm ±0.50 [.56in ±0.0] 6.mm [6.in] 8.5mm [9.9in] 0.00mm [5.in] 6.mm [8.5in] 8.5mm [7.5in] 6.mm [8.5in] 70mm ±0.5 [6.69in ±0.0] mm ±0.5 [8.7in ±0.0].6mm [9.5in] J F E E F J J.70mm [0.50in] 5.00mm [0.98in] H K 9.9mm ±.0 [.7in ±0.09] 5.7mm [0.6in] 6.0mm [.50in] 9.8mm [9.in] 5.87mm [.8in] 9.9mm [.7in].70mm [0.50in] 69.9mm [8.5in] TruPortal System ontroller Quick Reference 9 P/ B JA en-us
10 Input Figure : TruPortal controller 8VA/ V Input V Input POWER + POWER - 8VA/V Power Indication LE Aux Power Siren Relay Strobe Relay External Tamper Relay option if fitted Aux output Aux output O 0 SW V S oor ontroller Power Limited Power Limited oor ontroller Input Input Input Input Input Input Input Input Aux RTE R The EOL resistors and O contacts on the supervised inputs are shown as a typical configuration only and do not restrict the actual use of these inputs in the field. TR Aux RTE R TR Power Limited Power Limited Strike Relay Access Reader Egress Aux Reader Relay Strike Relay Access Reader Egress Aux Reader Relay 0 Buzzer Green LE Red LE Buzzer Green LE Red LE Input OSP omms LE IP Setting Input Input Input 6 OSP omms LE 5 Microcontroller Status LEs Power Limited Input RS85 Bus Input Input SAPP LE Term B - A + Test onfig SAPP LE Factory set : do not adjust RS85 Bus 7 Panasonic p/n R5 Speed LEs (0Mbits/00Mbits) 5 Term V oin ell SAPP LE Term SAPP LE B - A + B - A + RS85 Bus Power Limited Add shunt to Term ~ if 0Ω termination is required SOM Status LEs Term 6 7 V B - A + RS85 Bus Link (Activity) LE Link (Activity) LE SAPP LEs indicate bus comms VBUS WW Modem Socket + Ethernet Port Ethernet Port (Power limited to 00mA per port) USB ual Port Battery leads to be routed directly under board Power Limited BLAK etwork Interface (Access ontrol System Host ommunications) Maintain 0.5in spacing between power and on Power Limited circuits + - To secure battery use bracket p/n 8005B and of the 8- screws from the supplied accessories kit. on Power Limited RE To V battery The EOL resistors and O contacts on the supervised inputs are shown as a typical configuration only and do not restrict the actual use of these inputs in the field. The battery leads at must be routed away from power limited circuits. Maintain 0.5 inches (6 mm) spacing between non-power limited (that is, battery leads and A Mains) and power limited wiring. TruPortal System ontroller Quick Reference 0 P/ B 6JA en-us
TruPortal Output Expansion Board Quick Reference
TruPortal Output Expansion Board Quick Reference en-us Packing List Introduction A TruPortal system can be expanded by adding an Input/Output Expansion module (TP-ADD-IO-BRD) that consists of: One TruPortal
More informationTruPortal Dual Door Interface Module Quick Reference
TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers
More informationgenesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured
Australian Owned, Designed and Manufactured Master Unit GEN-001 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationinstallation quick guide integrated access control & environmental monitoring
installation quick guide integrated access control & environmental monitoring Introduction This Installation Quick Guide is suitable for standard wallmountable AX300 controllers. Illustrative technical
More informationgenesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010
Australian Owned, Designed and Manufactured Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products
More informationemerge Essential Access Control System
emerge Essential Access ontrol System Document Number: 620-100239, Rev. Installation Guide Linear LL 1950 amino Vida Roble, Suite 150 arlsbad, A 92008-6517 www.linearcorp.com Notices All rights strictly
More informationEA500. Installation Instructions Transponder
EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the
More informationTAC I/NETTM 1284, 1280, Security Control Unit
TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring
More informationMAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new Controller.
More informationSINGLE READER EXPANSION MODULE
SINGLE READER EXPANSION MODULE INSTALLATION GUIDE A D C - A C X 1 TR- SINGLE READER EXPANSION MODULE The ADC-ACX1 Single Reader Expansion Module provides a solution for interfacing to a one Wiegand reader
More informationPRO3200 Professional Modular Access Control Hardware
PRO3200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO3200 professional modular access control hardware is an advanced access control panel capable of providing
More informationUniversal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications
12 Universal Expander Module. Installation Notes. Revision 1.2 August. 2003. 1 Reporting Reporting with most Contact ID maps will treat the Mini Expander, Exp32 and Exp16 as the same. (With the exception
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationSuprex RS-485 SPX-7500 Wired Reader-Extender
Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778
More informationPRO2200 Professional Modular Access Control Hardware
PRO2200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO2200 professional modular access control hardware is an advanced access control panel capable of providing
More informationgenesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010
16-Input Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationVertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1
15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...
More informationQuick Start Installation Guide
RM-DCM-2 Quick Start Installation Guide Version G0 Document Part Number UM-215 May 2010 OVERVIEW The RM-DCM-2 is a UL294 Listed and UL1076 Listed door control module that includes the RM-4E Reader Module
More informationAccess control that easily integrates into the modern world
TruPortal Access control that easily integrates into the modern world QUICK START GUIDE Introduction TruPortal access control solutions have been engineered and designed to install quickly and easily right
More informationMR50 READER INTERFACE
2.75 [69.9] 2.35 [59.7] U1 MR50 READER INTERFAE Installation and Specifications: 1. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEAH, A 90815-1755, (562)986-9105 FAX (562) 986-9205 This device
More informationThe Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.
Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel
More informationAC-115 Compact Networked Single-Door Controller Hardware Installation and Programming
AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,
More informationTCNM-ACBB1 Installation Manual
The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationC1P2FX C1P2FX-IP C1P2FX-BT C1P2FX-BT-IP
Access control C1P2FX C1P2FX-IP C1P2FX-BT C1P2FX-BT-IP Technical manual p.2/32 Copyright : Eden Innovations No part of this publication may be reproduced, transmitted, transcribed or translated in any
More informationInstalling Sentor. Hardware Installation
Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3
More informationSEC-H-201 Security Controller
SEC-H-201 Security Controller INSTALLATION INSTRUCTIONS This document covers the mounting and wiring of the WEBs-AX Security Controller. It assumes that you are an engineer, technician, or service person
More informationCT5000. Offline controller user guide Instructions for Adaptable Series offline controller _C LED2 USB USB SCHLAGE STRIKE RELAY STATUS +5V
TP2 TP22 TP23 TP24 TP25 ALR_ ALR_ ALR_N MLR VDD RB7 RB8 OPEN IDAT ILK RX 3.3V TX N N *P56-04* P56-04 T5000 Offline controller user guide Instructions for Adaptable Series offline controller J3 J S3 MOUNT
More informationTS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual
TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual P/N MAINST-867/869 REV 07 ISS 26NOV13 Copyright Trademarks and patents Manufacturer ACMA compliance Contact information 2013 UTC Fire
More informationMR51e Reader Interface
J4 J TB6 TB5 TB4 TB3 VIN VO TB2 TB J7 2.75 [69.85] 0.2 [5.08] 2.35 [59.69] J3 MR5e Reader Interface Installation and Specifications. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA
More informationEP-ELVCTL Elevator Control (NION-16C48M)
EP-ELVCTL Elevator Control (NION-16C48M) Product Installation Document This document covers the procedures and specifications for installing the above listed unit and when appropriate, information regarding
More information2-Way Wireless I/O Expander Installation Guide
2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...
More informationPXL-250 Tiger Controller
PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and
More informationMR52 READER INTERFACE
IN IN2 IN3 IN4 INPUTS IN5 IN6 IN7 IN8 C www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 9085-755, (562)986-905 FAX (562) 986-9205 MR52 READER INTERFACE Installation and Specifications: This
More informationPW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules
Modular Access Control System The next generation of the PW-Series family improves on the existing PW technology to offer superior features and benefits. The PW-Series Modular Control System is an advanced
More informationAccess Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64
Essential Essential Plus Elite 36 Elite 64 Access Control System Document Number: 620-100239, Rev. D Installation Guide USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800)
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More informationACTpro 1500 Single Door IP Controller
ACTpro 1500 Single Door IP Controller ACTpro 1520 Single Door IP Controller with 12 V DC 2 amp power supply. Operating & Installation Instructions 18-00085 Issue 2 This manual refers to the ACTpro 1500
More informationCA-A480-A Elevator Controller. Reference & Installation Manual
CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................
More informationPOE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from
POE084824B v.1.1 PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. EN* Edition: 7 from 15.11.2017 Supersedes the edition: 6 from 22.11.2016 GREEN POWER CCTV PoE PSU features: DC 54V uninterruptible
More informationInstallation Instructions for UL Rev A
NetController II Installation Instructions for UL 864 30-3001-1008 Rev A Mounting Screw Andover Continuum Power Supply Connector Third-Party Power Supply Connector I/O Bus Connector Cover Mounting Screw
More informationQUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.
PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA
More informationTraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE
TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More informationControl Panels B5512/B4512. en UL Installation Instructions
Control Panels B551/B451 en UL Installation Instructions Control Panels Table of Contents en 3 Table of contents 1 Introduction 4 1.1 About documentation 4 1.1.1 Related documentation 4 1. Bosch Security
More informationModel: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:
Wiring Guide EP.L3800 Version 1.03 Last Updated: 13-10-2014 1 Note: L3800 is the serial enabled lift controller. L3800 will ship with a HIO board in a package which can cater up to 8 floors. It can connect
More informationPRT-RDS2 Standard 2 Reader Expander
PRT-RDS2 Standard 2 Reader Expander Installation Manual CONTENTS Protégé System... Introduction... Reader Expander... Features... Reader Expander Specifications... Protégé System Management Suite... Protégé
More informationINSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:
INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA-675-001 Revision 1.0 Date Code: 1-1-2018 Table of Contents Table of Figures... 3 SPECIFICATIONS:... 4 INSTALLATION... 5 General:... 5 Physical Installation
More informationExpandable Power Systems
Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.
More information~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
TR RS -0 0 /5 en - 06 00 RU/, RU/ (RUT /) ontrol and interlock devices rogrammable compact devices for local control, interlock and energy management functions in V systems They may be used for stand-alone
More informationACTpro Single Door IP Controller. Operating & Installation Instructions
ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control
More informationistar Pro Installation Guide
istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general
More informationgenesis TECHNICAL MANUAL Two-Door Controller GEN-045
Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationPM Series Power Meter
PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More informationRXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station
s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationInstallation Guide. Avigilon ACM Embedded Controller
Installation Guide Avigilon ACM Embedded Controller 2016, Avigilon Corporation. Portions 2003-2014 HID Global Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER and ACM
More informationEP/2 Installation Instructions
1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationIQ21x Series Controllers
IQ1x Series Controllers IQ1x SERIES CONTROLLERS Description Features The IQ1x series of intelligent controllers are designed for use as unitary controllers in building control systems. Full compatibility
More informationINSTALLATION INSTRUCTIONS 923P EntryCheck TM
801 Avenida Acaso, amarillo, a. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUTIONS 923P Entryheck TM The Entryheck 923P Indoor/Outdoor Keypad is a surface
More informationusing optional EMX 190 expansion modules), and makes access decisions based on its own distributed
Infinity ACX 700 Access Control Unit The Infinity ACX 700 is a programmable, stand-alone access controller that is a basic building block of the Infinity Security Management System. Each ACX 700 controls
More informationKT-300 DOOR CONTROLLER INSTALLATION MANUAL DN KANTECH SYSTEMS INC.
KT-300 DOOR CONTROLLER INSTALLATION MANUAL NOVEMBER 1999 KT-300 - ENGLISH INSTALLATION MANUAL - INTRODUCTION Part of the DSC group, Kantech Systems Inc. embraces the group's corporate philosophy of providing
More informationJunos WebApp Secure 5.0 Hardware Guide
Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a
More informationKT-400 Ethernet Four-Door Controller
KT-400 Ethernet Four-Door Controller Installation Manual DN2003-1202 V01.11 KT-400 Door Controller Installation Manual Table of contents Pre-Installation Information... 1 Copyright Information... 1 Safety
More informationWiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:
Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact
More informationEP1501 Intelligent Controller
J6 BT K K2 TB5 TB 2.35 [59.69] 2.75 [69.85] EP50 Intelligent Controller with Paired Reader Interface for One Physical Barrier Installation and Specifications: www.mercury-security.com 2355 MIRA MAR AVE.
More informationDisplay Panel BAT 100 LSN. en Operation Guide
Display Panel BAT 100 LSN en Operation Guide Display Panel Table of Contents en 3 Table of contents 1 Safety 4 2 Short information 4 3 System overview 5 4 Installation 6 5 Connection 11 6 Maintenance
More informationCP150B Vandal & Weather Resistant Keypad Security Systems
Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected
More informationRMB Peripheral Units Installation Guide
RMB Peripheral Units Installation Guide Part Number 65-000101 2011 by Kentrox, Inc. All rights reserved. Copyright 2011 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication
More informationT775S Series 2000 Expansion Module
T775S Series 000 Expansion Module INSTALLATION INSTRUTIONS PRODUT DESRIPTION The T775S008 Relay Expansion Module is a four relay device for use with the T775L007 and T775P00 Series 000 Electronic Stand-Alone
More informationIPassan Installation guide
IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...
More informationSigma Si. Extinguishant Status Unit (K , K , K , K , K , K , K , K )
Sigma Si Extinguishant Status Unit (K91100055, K91100056, K91110055, K91110056, K91111055, K91111056, K91111355, K91111356) Operation and Maintenance Manual Man1089 Issue 07 June 2013 Index Section Page
More informationC5S120 Installation and Connection Guide
C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before
More informationATS125x 4-Door DGP Installation Manual
GE Security ATS125x 4-Door DGP Installation Manual P/N 1065711 REV 1.0 ISS 27APR09 Copyright 2009 GE Security, Inc. This document may not be copied in whole or in part or otherwise reproduced without prior
More informationSmartLock Controller INSTALLATION MANUAL
SmartLock Controller INSTALLATI MANUAL November 2015 Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting...
More informationBeacon Power Supply Operating and Installation Instruction Manual
Beacon Power Supply Operating and Installation Instruction Manual Model: BNx000 Page 1 of 27 I. Warnings and Notices I. WARNING - To reduce the risk of fire or electric shock, do not expose this product
More informationLTEC Heat Pump DDC Controller
Document No. 09 Rev., May, 00 LTEC Heat Pump DDC Controller Product Description These instructions explain how to install or replace a LTEC (LonMark Terminal Equipment Controller) HP (Heat Pump) DDC Controller
More informationInstallation and Operation Guide
Installation and Operation Guide Network -Isolator Contents Introduction...3 Installation...3 Mounting...3 Wiring and Terminal locks...4 Network Connections...4 Configuration/...7 Power Connection...7
More informationThis Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.
This Datasheet for the IC660BBD110 Block 115Vac Input 16 Circuits http://www.cimtecautomation.com/parts/p-14435-ic660bbd110.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More informationQUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch Finger Vein Terminal Time Attendance & Access Control Version: 1.0 Date: Apr., 2017 1 2.4-Inch TFT LCD USB Storage Device Port Keypad& Card Reader Doorbell & LED Indicator Fingerprint
More informationQuick Start Installation Guide
RM-iCLASS Series Quick Start Installation Guide Version C0 Document Part Number UM-208 June 2009 OVERVIEW The RM-iClass Quick Start Installation Guide provides a summary of installation and connection
More informationNETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel.
Revised! see Protective Earthing Addendum cback NOTE: This equipment must only be installed and serviced by professional qualified personnel. The Network Concentrator Link is a fully self contained unit
More informationGallagher GBUS Devices
Gallagher GBUS Devices Gallagher GBUS I/O Devices provide flexible, cost effective input and output expansion options with an option to connect readers. Gallagher GBUS I/O Devices include the: Gallagher
More informationCardax FT Controller 3000
Installation Note Cardax FT Controller 000 CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any
More informationSigma-XT-ECU-LCS Extinguishant Control Unit Local Control Station Operation and Maintenance Manual
SigmaXTECULCS Extinguishant Control Unit Local Control Station Operation and Maintenance Manual SigmaXTECULCS Issue 1 October 2011 Index Section Page 1 Introduction... 3 2 Safety and mounting... 3 2.1
More informationInstallation Manual. Contents
CONCEPT IQ. Combined Installation Manual Rev 1.0 05/03 p1 Installation Manual Contents Section One: Concept IQ Hardware Overview 1.1 Typical Installation 1.2 Concept IQ Lockable Cabinet 1.3 Connecting
More informationOperating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage
Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling
More informationSecurity Management System by Diebold, Inc. LINX System Hardware Installation Guide
Security Management System by Diebold, Inc. LINX System Hardware Installation Guide INSTALLATION GUIDE LINX Integrated Security System WSD 2000 Weatherized Status Display Table of Contents Introduction
More informationAccess Control System - Installation Guide
ACS Access Control System - Installation Guide The Remotelock ACS is a cloud based access management system that integrates external door controllers with internal stand-alone Wi-Fi locks for a complete
More informationOBSOLETE. CanWorks itrax Two-Channel Control Unit Installation. Instruction Sheet P/N A
Instruction Sheet P/N 1047805A CanWorks itrax Two-Channel Installation WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other
More informationRMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A
RMB-3 Peripheral Unit Installation Guide INSTALLATION GUIDE Westell Technologies Part # 030-300812 Rev. A Copyright 2017 by Westell Technologies. All Rights Reserved. The material discussed in this publication
More informationSuprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502
Suprex Fiber Optic Reader-Extender SPX-7400 SPX-7410 Product Manual Reader-Extender Manual SPX-7400 Series EXP-2000 Suprex_FiberOptic_MAN_170502 Cypress Integration Solutions 30+ Years of Access Control
More informationINSTALLATION INSTRUCTIONS 921P EntryCheck TM
80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount
More informationFeatures: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras
S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras Edition: 3 from 15.11.2017 Supercedes the edition: 2 from 09.01.2017 EN** Features: Uninterruptible power supply of 8 IP cameras
More information