Remote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4)

Size: px
Start display at page:

Download "Remote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4)"

Transcription

1 File no. LR90200 Description mats and edges MC3, MC4 and Safety Mat Controllers Both metal enclosure and DINrail mount models available Control reliable Remote access to status, test and reset functions Built-in diagnostic indicators The Safety Mat controllers, MC3 and MC4 are used in conjunction with fourwire, normally open, mats where perimeter guarding is required. Their control reliable, surface-mount design sends a stop signal to the guarded machine whenever an object with sufficient weight is detected on the active mat surface. Also when the controller detects any of the mat wires are missing, broken, or mis-connected a stop signal is generated. When combined with a fourwire mat these controllers improve productivity while providing access guarding. Full visibility of and accessibility to the work area is always maintained. STI mat controllers meet the requirements of ANSI B for mats controllers and OSHA for general machine guarding. Universal power input (MC4) Selectable Automatic Start or Start/Reset Interlock Mode Circuitry monitors mat wiring integrity Options Lid-mounted reset key switch (MC4) Quick-disconnect mat fittings (MC4) E Go to the Engineering Guide in this catalog for in-depth information on standards and use of this product. D10

2 mats and edges Models Available This DIN-rail mount controller provides inputs and monitoring for six separate mat zones with a maximum combined area of 300 square feet. These six zones share a common output. Removable terminal blocks simplify installation when the controller is mounted on the DIN rail. Unit operates from 24 VDC only. MC3 This DIN-mount single zone mat controller has removable terminal blocks and operates from 24 VDC only. MC4 This single zone mat controller is housed in a NEMA 4, 12 (IP65) polyurethane-painted steel enclosure. Input power options include 100 to 240VAC - Auto Selecting, or 24 VDC. Additional Guarding Requirements A mat system is often only one part of a machine guarding solution. If the mat does not protect all access to the point of operation, additional guarding must be used. Safety mat systems should only be used to detect the presence, not the absence, of a force. Perimeter Guarding Requirements For perimeter guarding installations, the guarded machine or robot controller must be wired such that any stop signal generated by the mat system will cause an immediate stop of the hazardous motion. The machine or robot must only be restarted by the actuation of a manual reset switch. This reset switch must be located outside the area of hazardous motion and positioned such that the hazardous area can be observed by the switch operator. The purpose of this arrangement is to prevent a machine or robot from automatically restarting once the sensing weight is no longer detected by the mat sensing area. For the Latest Information Try Our Fax Back System at 1/916/ On the Internet: sales@sti.com D11

3 Specifications MC3 MC4 Performance Category 3 Safety Device: Yes Yes Yes Operating Area: Up to 300 sq. ft. (27.9 square meters) Up to 300 sq. ft. (27.9 square meters) Up to 300 sq. ft. (27.9 square meters) of mats for each controller of mats for each controller of mats for each controller Response Time: < 30 Ms (including mat response) < 30 Ms (including mat response) < 30 Ms (including mat response) Indications: 1 green = run, 1 red = stop 1 green = run, 1 red = stop, 1 green = run, 1 red = stop, 1 yellow = interlock, 1 orange = fault 1 green = mat clear 1 green = mat clear 6 orange = mat zone indicators Operational Mode Selectable: Automatic Start or Automatic Start or Automatic Start or Start/Restart Interlock Mode Start/Restart Interlock Mode Start/Restart Interlock Mode Electrical Power Input: 24 VDC ±15% < 2 VA 24 VDC ±15% < 3 VA 100 to 240 VAC, 50/60 Hz. Autoselecting ±15% or 24 VDC ±15% < 3 VA Safety Inputs: Connections for up to One 4-wire mat input Connections for up to six, 4-wire mats six, 4-wire mats Relay Outputs: Safety rated: 2 NO, 1 NC Safety rated: 2 NO, 2 NC Safety rated: 2 NO, 2 NC Non- rated: 1 NO, 1 NC Terminal Blocks: Removable with Removable with Cage clamp terminal strip pressure point screw pressure point screw Maximum Switched Current: 230 VAC, 6A, 1500 VA Max. 230 VAC, 6A, 1500 VA Max. Relay Life: Mechanical = 100M operations Mechanical = 10M operations Mechanical = 10M operations Options Reset Function: Remote (user supplied) Remote (user supplied) Lid mounted key-switch, Remote (user supplied) pushbutton or key-switch Mat Input Connectors: 6 mat inputs Up to six quick- disconnect connectors Power Input and Relay Output Connector: No No Yes Enclosure: Polycarbonate Polycarbonate Polyurethane-painted 14 ga. steel Mounting: 35mm DIN-rail 35mm DIN-rail Environmental Protection Rating: IP20 IP20 NEMA 4, 12, IP65 Operating Temp: 14 to 131 F (-10 to 55 C) 14 to 131 F (-10 to 55 C) 14 to 131 F (-10 to 55 C) Relative Humidity: 90% 90% 90% Vibration: 5-60 Hz at 5g max on three axis 5-60 Hz at 5g max on three axis 5-60 Hz at 5g max on three axis Shock: 10g for seconds 10g for seconds 10g for seconds 1000 shocks for each axis on 3 axis 1000 shocks for each axis on 3 axis 1000 shocks for each axis on 3 axis Shipping Weight: 1.5 lbs. (0.68 kg) 0.8 lbs. (0.22 kg) Approx. 9 pounds (4 kg.) Standards Conformity: CSA, NRTL/C TUV, CE, NRTL/C TUV, CE, NRTL/C Designed to meet or exceed: EN1760-1:1997 EN 954 ANSI/RIA ANSI/B : OSHA B Specifications are subject to change without notice. E Go to the Engineering Guide in this catalog for in-depth information on standards and use of this product. D12

4 R Dimensions in/mm STI 6-zone SafetyMat Controller WARNING SAFETY DEVICE TOP VIEW FRONT VIEW SLOT.18 X.23L 4.4 X 5.7L RT SIDE VIEW BOTTOM VIEW MC mm 61.2 mm 55 mm 75 mm 38 mm 98 mm 110 mm 1.5 mm Bottom View 35.5 mm Side View For the Latest Information Try Our Fax Back System at 1/916/ On the Internet: sales@sti.com D13

5 Dimensions in/mm MC (2 plcs) Ø Thru Hole (8 places) Ø0.875/ /28.70 Combo Knockout (3 places) Ø Combo Knockout (6 places) Typ Detail A Butterfly Latch Top Rivet Detail A (Clamp Wing E Go to the Engineering Guide in this catalog for in-depth information on standards and use of this product. D14

6 Safety Standards and Precautions An STI mat controller is a general purpose, mat control device and is not designed to guard any specific type, model or brand of machine. All related functions of the guarded machine controls including pneumatic, electric, logic or hydraulic controls must be control reliable. An STI mat controller, when combined with a four-wire mat meets ANSI/RIA R , ANSI B and the following applicable OSHA standards. When used with mechanical power presses, OSHA standard (c) applies. For other applications the requirements of section apply. Only use a mat controller and four-wire mat system on machinery that stops consistently and immediately anywhere in its cycle or stroke. Never use a mat controller and four-wire mat system on a fullrevolution clutched press or machine. Access to the point of operation or hazardous machine area not protected by the mat controller and four-wire mat system must be guarded by fencing, barriers or other appropriate methods. The purchaser, installer and employer are responsible for meeting all local state and federal government laws, rules, codes or regulations relating to the proper use, installation, operation and maintenance of this control and the guarded machine. See Installation and Operation Manual for additional information. All application examples described are for illustration purposes only. Actual installations will differ from those indicated. Ordering Information Use the chart below to specify a specific model. For example, a MC would be a MC4 controller with no input connector, a key-switch, VAC auto-selecting and 6 mat connectors. Configuration MC3 Six-zone Safety Mat Controller, IP20, DIN rail mount, 24VDC, removable terminal blocks 24VDC, 2 N0 & 2 NC outputs, 35mm DIN rail mount, removable terminal blocks, automatic start or start/restart, interlock operating mode Configuration MC4 MC4 controller with features outlined below Connectors (MC4 only) 0 No input connector 1 Connector for power input and output contacts Key Switch (MC4 only) 0 No key switch 1 Lid mounted key-switch Power Input (MC4 only) 0 24 VDC to 240 VAC auto-selecting Input Connectors (MC4 only) 0 No mat input connectors 1 to 6 mat connectors (specify a number) For the Latest Information Try Our Fax Back System at 1/916/ On the Internet: sales@sti.com D15

Safety Mats & Area Guarding

Safety Mats & Area Guarding Safety Mats & Area Guarding MC Controllers MC MC, MC and MC Series Safety Mat Controllers The MC Series safety mat controllers are used in conjunction with a four-wire, normally open, safety mat where

More information

Guard Mode. Machine Test Signal. MPCE Checking. Remote Function Access. Status and Diagnostic indicator lights visible on controller enclosure lid

Guard Mode. Machine Test Signal. MPCE Checking. Remote Function Access. Status and Diagnostic indicator lights visible on controller enclosure lid MicroSafe File No. LR90200 Description MicroSafe Ultra-compact transmitter and receiver 1 x 1.25 inches (25 x 32 mm) 0.8 inch (20 mm) resolution 29.5 foot (9 m) range Protected heights from 8 to 48 inches

More information

No cable required between transmitter and receiver. Exact Channel Select. Floating Blanking. Choice of operating modes.

No cable required between transmitter and receiver. Exact Channel Select. Floating Blanking. Choice of operating modes. MiniSafe File No. LR90200 Description MiniSafe 0.75 inch (19mm) resolution 65 foot (20 meter) range Protected heights from 10 to 55 inches (263 to 1394mm) Compact size 1.4 x 2 inches (35 x 50mm) Simple

More information

OptoFence. OptoFence OF OF safety light curtains. Description

OptoFence. OptoFence OF OF safety light curtains. Description File No. LR90200 Description OptoFence OF4600-50 2.0 inch (53mm) resolution 80 foot (24 meter) range Four protected heights available: 27, 41, 55 and 69 inches (700, 1046, 1394 and 1741mm) Compact size

More information

Magnetically Actuated Safety Interlock Switches

Magnetically Actuated Safety Interlock Switches Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,

More information

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Safety Light Curtains MP2100 MP2100 For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. MiniProtect Light Curtains Resolution:

More information

EM-F-7G Safety Extension Module

EM-F-7G Safety Extension Module EM-F-7G Safety Extension Module One-channel control with four safety output channels Features Safety Extension Module provides additional safety outputs for a Primary Safety Device (for example, an E-stop

More information

MiniSafe MS4600 MS4600. safety light curtains. Description

MiniSafe MS4600 MS4600. safety light curtains. Description Rev. 11.07 MS4600 C US File No. LR90200 C R US escription MiniSafe MS4600 Resolution: 14 mm (0.55 in.), 19 mm (0.75 in.) or 30 mm (1.18 in.) resolution Range: 7.5 m (25 ft.) range for the 14 mm resolution

More information

Versatile Safety Interlock Switch with Guard Door Locking

Versatile Safety Interlock Switch with Guard Door Locking R Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved Versatile Safety Interlock Switch with Guard Door Locking High locking force of 450 pounds locks guard door shut until

More information

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. R Safety Interlock Switches MA Series MA For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Magnetically Actuated Safety

More information

Compact Coded Magnetic Safety Interlock Switch and Control Units

Compact Coded Magnetic Safety Interlock Switch and Control Units C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch

More information

Magnetically Actuated Safety Interlock Switches

Magnetically Actuated Safety Interlock Switches Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic

More information

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C r Safety Interlock Switches MA Series MA Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic to satisfy most application

More information

Shown here with optional quick-disconnect cable kit.

Shown here with optional quick-disconnect cable kit. US File No. LR9000 Description BeamSafe 0 m (00 ft.) range Four possible transmit codes eliminate crosstalk from multiple units in the same area II Long-Range, Single-Beam Safety ontrol Signal strength

More information

Machine Safety. Products

Machine Safety. Products January 23 Vol. 2, Ref. No. [1263] -1 Machine Safety Products Contents Description Page............................................. -2 Key Interlock Switches DIN Models.............................. -9

More information

PRSU/5 Safety Interface Controller

PRSU/5 Safety Interface Controller PRSU/5 Safety Interface Controller Installation Instructions 1. INTRODUCTION Tapeswitch PRSU/5 control units are designed to be used with Tapeswitch pressure sensitive sensors to form a complete safety

More information

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches R Safety Interlock Switches CM Series CM For full product information, visit www.sti.com. Use the SpeedSPEC Code for quick access to the specific web page. Most Diverse and Flexible Line of Coded Magnetic

More information

Making Hazardous Operations Safe and Productive

Making Hazardous Operations Safe and Productive NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series

More information

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function Safety Guard Switching Unit CSM DS_E_6_1 A Safety Measure for Hazardous Operations That Does Not Lower Productivity Two functions support two types of application: Auto switching: For applications where

More information

Safety Monitoring Relays

Safety Monitoring Relays Safety Monitoring Relays Contents Selection Guide I-2 Safety Monitoring Relays G9SA I-6 SR101A I-12 SR103AM I-13 SR104P I-17 SR105E I-17 SR106ED I-21 SR108AD & SR109AD I-18 SR120MP I-21 SR125SMS45 I-22

More information

SafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay

SafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay EN 954 SafeC S Safety Relay SafeC S: Narrow construction of only 22.5 mm SafeC S is a sturdy and extremely inexpensive safety relay which impresses with its unusual efficiency and versatility, despite

More information

Datasheet - SLB 200-C04-1R

Datasheet - SLB 200-C04-1R 14.02.2013-17:06:30h Datasheet - SLB 200-C04-1R Safety light barriers / Safety monitoring modules to monitor safety light barriers / SLB 200-C Up to 2 light barrier pairs SLB 200 can be connected 1 safety

More information

RM-2 and RM-2AC. Resource Module Converts Solid-State Outputs to Force-Guided Relay Outputs

RM-2 and RM-2AC. Resource Module Converts Solid-State Outputs to Force-Guided Relay Outputs esource M- and Module M-ACM- C US C US File No. L9000- escription M- and M-AC esource Module Converts Solid-State s to Force-Guided elay s Converts the solid-state safety and auxiliary outputs of one STI

More information

Nokeval. FD100 series. User Manual

Nokeval. FD100 series. User Manual Nokeval FD100 series User Manual Contents Document information... 2 FD100A4 and FD100A6 field displays... 3 Power supply connection... 4 Configuring... 5 Specifications... 7 Document information Device

More information

Mat Controller ... MC6 Series. Installation and Operating Manual Original Instructions 1 / 888 /

Mat Controller ... MC6 Series. Installation and Operating Manual Original Instructions 1 / 888 / Mat Controller MC6 Series Installation and Operating Manual OMRON Scientific Technologies Inc. Manufacturing and Sales Office 6550 Dumbarton Circle Fremont CA 94555-3605 USA 1 / 888 / 510-4357 Tel: 510/608-3400

More information

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W Selection Guide Selection Guide PS5R Slim Line PS5R PS3L Operator Interfaces Communication & Networking PLCs NEW Models Appearance Automation Software Page 107 113 118 Housing Plastic Metal Mounting DIN

More information

Machine Safety Switches

Machine Safety Switches Machine Safety Switches Style SI-MAG Series ic Style Switch Features Non-contact safety switches are the best choice for washdown applications; the switch components are sealed and rated NEMA 4X, IEC IP67

More information

onlinecomponents.com

onlinecomponents.com FF-RE59292 Extension Module Instructions for use (pending) (pending) IMPROPER INTALLATION Consult with U and/or European safety agencies and their requirements when designing a machine control, interface

More information

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT A0-10 ANALOG OUTPUT Instruction Manual April 2001 NALOG OUTPUT Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the

More information

XPSMCMDO Digital output pairs expansion modules with screw term

XPSMCMDO Digital output pairs expansion modules with screw term Characteristics 2 Digital output pairs expansion modules with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs

More information

Mat Controller MC4 Series

Mat Controller MC4 Series Mat Controller MC4 Series Installation and Operating Manual Scientific Technologies Inc. Optical Sensor Division Manufacturing and Sales Office 6550 Dumbarton Circle, Fremont, CA 94555-3611 Phone 510/608-3400

More information

MC Controllers. MC3, MC4 and MC6 Series Safety Mat Controllers. Description. Safety Mats & Area Guarding. Options MC6 MC3

MC Controllers. MC3, MC4 and MC6 Series Safety Mat Controllers. Description. Safety Mats & Area Guarding. Options MC6 MC3 Safety Mats & Area Guarding MC Controllers MC or full product information, visit www.sti.com. Use the SpeedSPEC Code for quick access to the specific web page. MC, MC and MC Series Safety Mat Controllers

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

Dold BH5928 Series 2-Channel Emergency Stop and Safety Gates with Delay

Dold BH5928 Series 2-Channel Emergency Stop and Safety Gates with Delay Dold Series 2-Channel Emergency Stop and Safety Gates with Delay -92-61-24-1 Part umber Price Marking Type Voltage Outputs Time Delay -92-61-24-1 2-channel E-STOP / GATE 24 VDC 3.O. time delay positive

More information

ES-TN-1H.. E-Stop Safety Modules with Fixed Delay

ES-TN-1H.. E-Stop Safety Modules with Fixed Delay ES-TN-H.. E-Stop Safety Modules with Fixed Delay Models with fixed delay, ranging from.25 second to 2 seconds Model Models Delay ES-TN-H ES-TN-H2 ES-TN-H3 ES-TN-H4 ES-TN-H7 ES-TN-H8 ES-TN-H9 ES-TN-H ES-TN-H

More information

Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts.

Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts. Peak G 15min Handheld Electrostatic Meter Series IZH10 How to Order IZH10 Option Nil H None High-voltage measuring handle Accessories and Option / Part Number for Individual Parts The ground wire and soft

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and

More information

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v IES-0920 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail User Manual v1.00-1206 Preface This manual describes how to install and use the Industrial Ethernet Switch. This switch integrates full wire

More information

Expansion Unit G9SX-EX Safety 2 Instantaneous safety outputs

Expansion Unit G9SX-EX Safety 2 Instantaneous safety outputs Flexible Safety Unit / Safety Guard Switching Unit G9SX/G9SX-GS CSM_G9SX_G9SX-GS_DS_E_8_1 Logical Function Adds Flexibility to Various Safety Circuits Be sure to read the Safety Precautions on page 45.

More information

ZC Series Zone Monitoring Controllers

ZC Series Zone Monitoring Controllers ZC Series Zone Monitoring Controllers Installation Instructions MANUAL Reset Controllers Model Description Part Number ZC-1 1 Zone Controller 0421 ZC-2 2 Zone Controller 0422 ZC-3 3 Zone Controller 0423

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Safety Interlock Switches TL8012-S TL8012 For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Versatile Safety Interlock

More information

Models IM-T-9A and IM-T-11A Interface Modules

Models IM-T-9A and IM-T-11A Interface Modules Models and IM-T-11A Interface Modules Interface Modules for use with a Primary Device Interface Modules provide isolated safety output contacts for a primary safety device (e.g., a safety light screen

More information

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY REVISION 3-B-041318 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document

More information

E-Stop Safety Modules with Adjustable Delay

E-Stop Safety Modules with Adjustable Delay E-Stop Safety Modules with Adjustable Delay Models ES-TN-14H5 with -2 second delay, ES-TN-14H6 with -2 second delay Features Selectable Auto-Reset or monitored Manual Reset. Auto or manual power-up One-

More information

rcc.1081 Installation Instructions

rcc.1081 Installation Instructions rcc.1081 Installation Instructions Table of Contents Introduction...1 Specifications...2 Mounting...3 Wiring...5 Wiring Method...7 BACnet Network Wiring...8 Setting BACnet Address...9 Setting the BACnet

More information

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend. Door Interlock Switch Power Switch with Minimum Contact Gap of 3 mm Offers the minimum contact gap of 3 mm required for power switches as standard equipment. Highly reliable design conforms to European

More information

VI - Safety techniques

VI - Safety techniques VI - Safety techniques In this chapter we discuss some of the more significant and common safety techniques and introduce some of the vocabulary used by safety equipment manufacturers like Honeywell to

More information

PGR-3200 MANUAL INSULATION MONITOR

PGR-3200 MANUAL INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN

More information

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General

More information

OS3101. Operator Presence Detection in Work Areas with Complex Shapes. Safety Laser Scanner. Ordering Information. Safety/Area.

OS3101. Operator Presence Detection in Work Areas with Complex Shapes. Safety Laser Scanner. Ordering Information. Safety/Area. Laser Scanner / Operator Presence Detection in Work s with Complex Shapes A Type 3 Laser Scanner in compliance with IEC 61496-1/-3. Two patterns of protective and warning area combinations can be set to

More information

DC Outdoor Power Supply/Chargers

DC Outdoor Power Supply/Chargers DC Outdoor Power Supply/Chargers Installation Guide Models Include: WayPoint3 WayPoint7-2.5A @ 12VDC or 24VDC. - 6A @ 12VDC or 24VDC. - 115/230VAC input. - 115VAC input. WayPoint5 WayPoint7V - 4A @ 12VDC

More information

CompactBlock Guard I/O EtherNet/IP Safety Modules

CompactBlock Guard I/O EtherNet/IP Safety Modules Installation Instructions CompactBlock Guard I/O EtherNet/IP Safety Modules Catalog Numbers 1791ES-IB8XOBV4, 1791ES-IB16 Topic Page Important User Information 2 North American Hazardous Location Approval

More information

Safety Relay Unit (I/O Unit Type)

Safety Relay Unit (I/O Unit Type) Safety Relay Unit (I/O Unit Type) CQM1-SF200/ CS1W-SF200 Same Dimensions as I/O Unit Less Installation Space and Wiring Required Safety Relay Unit that can be used as an I/O Unit for OMRON s CQM1H and

More information

Level-Lance Model 5400A

Level-Lance Model 5400A Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing

More information

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001 SLATE Digital I/O Module R8001D4001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to

More information

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.

More information

Safety Interlock Switches

Safety Interlock Switches r Safety Interlock Switches Compact Universal Tongue- Operated Safety Interlock Switch Strong and versatile the compact size of the strong, glass-filled polyester housing can be used in many applications

More information

Six Input Emergency Stop Monitoring Safety Relay

Six Input Emergency Stop Monitoring Safety Relay Six Input Emergency Stop Monitoring Safety Relay Model ES-TA-3D1 with DeviceNet CONTENTS Section 1 Product Description 3 Section 2 Emergency Stop Switch 4 Requirements Section 3 Mounting the Control 5

More information

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.

More information

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX User Manual MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX CE MARKING This equipment complies with the requirements relating to electromagnetic compatibility, EN 55022 class A for ITE, the

More information

XPSMCMMX inputs 2 output pairs expansion module with screw term

XPSMCMMX inputs 2 output pairs expansion module with screw term Characteristics 8 inputs 2 output pairs expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs

More information

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector Gigabit Ethernet Switch with PoE+ for Industrial Use Page 2/11 Table of Contents General... 3 Benefits... 3 Front View...

More information

Solid-state Timer H3YN

Solid-state Timer H3YN Solid-state Timer H3YN Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

ASI Systems ML5740A Series

ASI Systems ML5740A Series ML5740A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5740A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions

More information

General-Purpose Photoelectric Sensor

General-Purpose Photoelectric Sensor General-Purpose Photoelectric Sensor Compact Limit Switch Style with Universal Supply FET output allows for solid state switching of AC or DC Universal AC/DC power supply Choose cable or connector types

More information

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters DESCRIPTION Pump-Down Controller Input Scalable Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters The Model 4052 Pump-Down Controller provides total control for duplex pumping

More information

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately) Solid-state Timer Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3 Overview Safety notes 1 SITOP power supply Manual Description, device design, dimension drawing 2 Mounting/removal 3 Mounting position, mounting clearances 4 Installation 5 Technical data 6 Safety, approvals,

More information

Safety Control Relay Product Catalog

Safety Control Relay Product Catalog Product Catalog Wall Mount for use with Safety Mats Safety Edges Safety Bumpers Safety Sensors 2 wire Safety Sensors 4 wire DIN Rail Mount Intrinsically Safe Explosion Proof Wall Mount Introduction The

More information

XPSMCMDI Input expansion module with screw term

XPSMCMDI Input expansion module with screw term Characteristics 16 Input expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs Number of outputs

More information

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1- KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

Crane Control Class 9004

Crane Control Class 9004 Catalog 17 CONTENTS Description.....................................................Page Pricing and Ordering Information...................................... 140 Dimensions and Weights............................................

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

TYPE 4 SAFETY LIGHT CURTAIN EOS4

TYPE 4 SAFETY LIGHT CURTAIN EOS4 TYPE 4 SAFETY LIGHT CURTAIN is a compact Type 4 light curtain with competitive performance and innovative features. Its features include: Cross section Minimal cross section - 28 x 30 mm. No blind area

More information

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS Safety Controller Suitable for use with Coded-Magnet Sensor Part Numbers below BNS250... BNS33... BNS303...

More information

Safety Monitoring Relays

Safety Monitoring Relays Safety Monitoring Relays G9SA G9SA Safety Relay Unit Four kinds of 45-mm wide units are available: A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a two-hand controller.

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 50729 Page of 9 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.com, www.smartscan.com

More information

NE1A/DST1. DeviceNet Safety System

NE1A/DST1. DeviceNet Safety System System Omron now offers a DeviceNet compatible Safety System, that can be used 3-ways: as a Standalone controller, as a Safety network expandable with remote I/O blocks, or combined with DeviceNet to form

More information

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide

More information

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX Entry Line Fast Ethernet Switch Fast Ethernet Switch for Industrial Use Page 2/11 Table of Contents General... 3 Benefits... 3 Front

More information

S66 Series Electronic Fan Speed Control

S66 Series Electronic Fan Speed Control FANs 121, 125, 1628.3 Product/Technical Bulletin S66 Issue Date 0918 S66 Series Electronic Fan Speed Control The S66 Series Electronic Fan Speed Control is designed to modulate the speed of single-phase,

More information

MobileView Junction Box

MobileView Junction Box Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard

More information

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number Standard Series Key features: Wide power range: 7.W-24W Universal input : 7.W-W: 8-264V AC/1-37V DC 1W: 8-2V AC/17-264V AC 24-37V DC (selectable) W, W, 24W: 8-264V AC/11-3V DC Overcurrent/overvoltage protection

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information

PCI 2 Axis Servo Card

PCI 2 Axis Servo Card Installation Instructions PCI 2 Axis Servo Card (Catalog Number 1784-PM02AE) This manual provides the instructions for installing the PCI 2 Axis Servo card (1784-PM02AE) in a PC computer using the NT operating

More information

Signamax Connectivity Systems

Signamax Connectivity Systems Signamax Connectivity Systems Hardened Ethernet Switch Model -065-7405TB 065-7408ATB 065-74091FXSTTB 065-74091FXSCTB U S E R S G U I D E 1 Quick Start Guide Hardened Ethernet Switch This quick start guide

More information

Series Panel Mounted Control Devices

Series Panel Mounted Control Devices E_Master2012.qxd:NEW_E_Master_temp.qxd 1/27/12 4:28 PM Page 1 Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2"

More information

MSR178DP. Description. Features. Specifications

MSR178DP. Description. Features. Specifications MSR178DP Description The MSR178DP is a multi-function time-delay relay for use in safety circuits. It can be configured by the user to perform on-delay, offdelay or single-pulse modes. It is used for applications

More information

7511 / / / 711 / / 731 / Preset 27

7511 / / / 711 / / 731 / Preset 27 22 Timers Timers Electronic 23 7511 / 3410 23 6320 / 720-6300 24 ElectRo-MeCH 25 710 / 711 / 720 25 722 / 731 / 732 26 Preset 27 7932 27 Electronic 23 7511 Series 8 digit self powered LCD electronic timer

More information

Safety Light Curtains GuardShield Remote Teach

Safety Light Curtains GuardShield Remote Teach Specifications Presence Sensing Safety Devices Description The system provides a remote means of changing a fixed blanking configuration within the GuardShield safety light curtain. This keyswitch box

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

Tecnología en Electrónica y Control SRL Ficha Técnica

Tecnología en Electrónica y Control SRL Ficha Técnica Tecnología en Electrónica y Control SRL Ficha Técnica Relé de seguridad Tecnología en Electrónica y Control SRL Oficina Central Wüthrich 949 San Carlos Centro (S3013DES) / Santa Fe / Argentina Tel./Fax/Líneas

More information

ETD-BL-1T-OFF-CC- 10S

ETD-BL-1T-OFF-CC- 10S Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA SUPRESOR PRINCIPAL DE 300 KA. ST-SMLA 3N4 TRANSIENT VOLTAGE SURGE SUPPRESSORS. PROTECTION AGAINST

More information

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index

More information