Remote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4)
|
|
- Morgan Newton
- 6 years ago
- Views:
Transcription
1 File no. LR90200 Description mats and edges MC3, MC4 and Safety Mat Controllers Both metal enclosure and DINrail mount models available Control reliable Remote access to status, test and reset functions Built-in diagnostic indicators The Safety Mat controllers, MC3 and MC4 are used in conjunction with fourwire, normally open, mats where perimeter guarding is required. Their control reliable, surface-mount design sends a stop signal to the guarded machine whenever an object with sufficient weight is detected on the active mat surface. Also when the controller detects any of the mat wires are missing, broken, or mis-connected a stop signal is generated. When combined with a fourwire mat these controllers improve productivity while providing access guarding. Full visibility of and accessibility to the work area is always maintained. STI mat controllers meet the requirements of ANSI B for mats controllers and OSHA for general machine guarding. Universal power input (MC4) Selectable Automatic Start or Start/Reset Interlock Mode Circuitry monitors mat wiring integrity Options Lid-mounted reset key switch (MC4) Quick-disconnect mat fittings (MC4) E Go to the Engineering Guide in this catalog for in-depth information on standards and use of this product. D10
2 mats and edges Models Available This DIN-rail mount controller provides inputs and monitoring for six separate mat zones with a maximum combined area of 300 square feet. These six zones share a common output. Removable terminal blocks simplify installation when the controller is mounted on the DIN rail. Unit operates from 24 VDC only. MC3 This DIN-mount single zone mat controller has removable terminal blocks and operates from 24 VDC only. MC4 This single zone mat controller is housed in a NEMA 4, 12 (IP65) polyurethane-painted steel enclosure. Input power options include 100 to 240VAC - Auto Selecting, or 24 VDC. Additional Guarding Requirements A mat system is often only one part of a machine guarding solution. If the mat does not protect all access to the point of operation, additional guarding must be used. Safety mat systems should only be used to detect the presence, not the absence, of a force. Perimeter Guarding Requirements For perimeter guarding installations, the guarded machine or robot controller must be wired such that any stop signal generated by the mat system will cause an immediate stop of the hazardous motion. The machine or robot must only be restarted by the actuation of a manual reset switch. This reset switch must be located outside the area of hazardous motion and positioned such that the hazardous area can be observed by the switch operator. The purpose of this arrangement is to prevent a machine or robot from automatically restarting once the sensing weight is no longer detected by the mat sensing area. For the Latest Information Try Our Fax Back System at 1/916/ On the Internet: sales@sti.com D11
3 Specifications MC3 MC4 Performance Category 3 Safety Device: Yes Yes Yes Operating Area: Up to 300 sq. ft. (27.9 square meters) Up to 300 sq. ft. (27.9 square meters) Up to 300 sq. ft. (27.9 square meters) of mats for each controller of mats for each controller of mats for each controller Response Time: < 30 Ms (including mat response) < 30 Ms (including mat response) < 30 Ms (including mat response) Indications: 1 green = run, 1 red = stop 1 green = run, 1 red = stop, 1 green = run, 1 red = stop, 1 yellow = interlock, 1 orange = fault 1 green = mat clear 1 green = mat clear 6 orange = mat zone indicators Operational Mode Selectable: Automatic Start or Automatic Start or Automatic Start or Start/Restart Interlock Mode Start/Restart Interlock Mode Start/Restart Interlock Mode Electrical Power Input: 24 VDC ±15% < 2 VA 24 VDC ±15% < 3 VA 100 to 240 VAC, 50/60 Hz. Autoselecting ±15% or 24 VDC ±15% < 3 VA Safety Inputs: Connections for up to One 4-wire mat input Connections for up to six, 4-wire mats six, 4-wire mats Relay Outputs: Safety rated: 2 NO, 1 NC Safety rated: 2 NO, 2 NC Safety rated: 2 NO, 2 NC Non- rated: 1 NO, 1 NC Terminal Blocks: Removable with Removable with Cage clamp terminal strip pressure point screw pressure point screw Maximum Switched Current: 230 VAC, 6A, 1500 VA Max. 230 VAC, 6A, 1500 VA Max. Relay Life: Mechanical = 100M operations Mechanical = 10M operations Mechanical = 10M operations Options Reset Function: Remote (user supplied) Remote (user supplied) Lid mounted key-switch, Remote (user supplied) pushbutton or key-switch Mat Input Connectors: 6 mat inputs Up to six quick- disconnect connectors Power Input and Relay Output Connector: No No Yes Enclosure: Polycarbonate Polycarbonate Polyurethane-painted 14 ga. steel Mounting: 35mm DIN-rail 35mm DIN-rail Environmental Protection Rating: IP20 IP20 NEMA 4, 12, IP65 Operating Temp: 14 to 131 F (-10 to 55 C) 14 to 131 F (-10 to 55 C) 14 to 131 F (-10 to 55 C) Relative Humidity: 90% 90% 90% Vibration: 5-60 Hz at 5g max on three axis 5-60 Hz at 5g max on three axis 5-60 Hz at 5g max on three axis Shock: 10g for seconds 10g for seconds 10g for seconds 1000 shocks for each axis on 3 axis 1000 shocks for each axis on 3 axis 1000 shocks for each axis on 3 axis Shipping Weight: 1.5 lbs. (0.68 kg) 0.8 lbs. (0.22 kg) Approx. 9 pounds (4 kg.) Standards Conformity: CSA, NRTL/C TUV, CE, NRTL/C TUV, CE, NRTL/C Designed to meet or exceed: EN1760-1:1997 EN 954 ANSI/RIA ANSI/B : OSHA B Specifications are subject to change without notice. E Go to the Engineering Guide in this catalog for in-depth information on standards and use of this product. D12
4 R Dimensions in/mm STI 6-zone SafetyMat Controller WARNING SAFETY DEVICE TOP VIEW FRONT VIEW SLOT.18 X.23L 4.4 X 5.7L RT SIDE VIEW BOTTOM VIEW MC mm 61.2 mm 55 mm 75 mm 38 mm 98 mm 110 mm 1.5 mm Bottom View 35.5 mm Side View For the Latest Information Try Our Fax Back System at 1/916/ On the Internet: sales@sti.com D13
5 Dimensions in/mm MC (2 plcs) Ø Thru Hole (8 places) Ø0.875/ /28.70 Combo Knockout (3 places) Ø Combo Knockout (6 places) Typ Detail A Butterfly Latch Top Rivet Detail A (Clamp Wing E Go to the Engineering Guide in this catalog for in-depth information on standards and use of this product. D14
6 Safety Standards and Precautions An STI mat controller is a general purpose, mat control device and is not designed to guard any specific type, model or brand of machine. All related functions of the guarded machine controls including pneumatic, electric, logic or hydraulic controls must be control reliable. An STI mat controller, when combined with a four-wire mat meets ANSI/RIA R , ANSI B and the following applicable OSHA standards. When used with mechanical power presses, OSHA standard (c) applies. For other applications the requirements of section apply. Only use a mat controller and four-wire mat system on machinery that stops consistently and immediately anywhere in its cycle or stroke. Never use a mat controller and four-wire mat system on a fullrevolution clutched press or machine. Access to the point of operation or hazardous machine area not protected by the mat controller and four-wire mat system must be guarded by fencing, barriers or other appropriate methods. The purchaser, installer and employer are responsible for meeting all local state and federal government laws, rules, codes or regulations relating to the proper use, installation, operation and maintenance of this control and the guarded machine. See Installation and Operation Manual for additional information. All application examples described are for illustration purposes only. Actual installations will differ from those indicated. Ordering Information Use the chart below to specify a specific model. For example, a MC would be a MC4 controller with no input connector, a key-switch, VAC auto-selecting and 6 mat connectors. Configuration MC3 Six-zone Safety Mat Controller, IP20, DIN rail mount, 24VDC, removable terminal blocks 24VDC, 2 N0 & 2 NC outputs, 35mm DIN rail mount, removable terminal blocks, automatic start or start/restart, interlock operating mode Configuration MC4 MC4 controller with features outlined below Connectors (MC4 only) 0 No input connector 1 Connector for power input and output contacts Key Switch (MC4 only) 0 No key switch 1 Lid mounted key-switch Power Input (MC4 only) 0 24 VDC to 240 VAC auto-selecting Input Connectors (MC4 only) 0 No mat input connectors 1 to 6 mat connectors (specify a number) For the Latest Information Try Our Fax Back System at 1/916/ On the Internet: sales@sti.com D15
Safety Mats & Area Guarding
Safety Mats & Area Guarding MC Controllers MC MC, MC and MC Series Safety Mat Controllers The MC Series safety mat controllers are used in conjunction with a four-wire, normally open, safety mat where
More informationGuard Mode. Machine Test Signal. MPCE Checking. Remote Function Access. Status and Diagnostic indicator lights visible on controller enclosure lid
MicroSafe File No. LR90200 Description MicroSafe Ultra-compact transmitter and receiver 1 x 1.25 inches (25 x 32 mm) 0.8 inch (20 mm) resolution 29.5 foot (9 m) range Protected heights from 8 to 48 inches
More informationNo cable required between transmitter and receiver. Exact Channel Select. Floating Blanking. Choice of operating modes.
MiniSafe File No. LR90200 Description MiniSafe 0.75 inch (19mm) resolution 65 foot (20 meter) range Protected heights from 10 to 55 inches (263 to 1394mm) Compact size 1.4 x 2 inches (35 x 50mm) Simple
More informationOptoFence. OptoFence OF OF safety light curtains. Description
File No. LR90200 Description OptoFence OF4600-50 2.0 inch (53mm) resolution 80 foot (24 meter) range Four protected heights available: 27, 41, 55 and 69 inches (700, 1046, 1394 and 1741mm) Compact size
More informationMagnetically Actuated Safety Interlock Switches
Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Safety Light Curtains MP2100 MP2100 For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. MiniProtect Light Curtains Resolution:
More informationEM-F-7G Safety Extension Module
EM-F-7G Safety Extension Module One-channel control with four safety output channels Features Safety Extension Module provides additional safety outputs for a Primary Safety Device (for example, an E-stop
More informationMiniSafe MS4600 MS4600. safety light curtains. Description
Rev. 11.07 MS4600 C US File No. LR90200 C R US escription MiniSafe MS4600 Resolution: 14 mm (0.55 in.), 19 mm (0.75 in.) or 30 mm (1.18 in.) resolution Range: 7.5 m (25 ft.) range for the 14 mm resolution
More informationVersatile Safety Interlock Switch with Guard Door Locking
R Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved Versatile Safety Interlock Switch with Guard Door Locking High locking force of 450 pounds locks guard door shut until
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches MA Series MA For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Magnetically Actuated Safety
More informationCompact Coded Magnetic Safety Interlock Switch and Control Units
C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch
More informationMagnetically Actuated Safety Interlock Switches
Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic
More informationSafety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C
r Safety Interlock Switches MA Series MA Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic to satisfy most application
More informationShown here with optional quick-disconnect cable kit.
US File No. LR9000 Description BeamSafe 0 m (00 ft.) range Four possible transmit codes eliminate crosstalk from multiple units in the same area II Long-Range, Single-Beam Safety ontrol Signal strength
More informationMachine Safety. Products
January 23 Vol. 2, Ref. No. [1263] -1 Machine Safety Products Contents Description Page............................................. -2 Key Interlock Switches DIN Models.............................. -9
More informationPRSU/5 Safety Interface Controller
PRSU/5 Safety Interface Controller Installation Instructions 1. INTRODUCTION Tapeswitch PRSU/5 control units are designed to be used with Tapeswitch pressure sensitive sensors to form a complete safety
More informationCM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches
R Safety Interlock Switches CM Series CM For full product information, visit www.sti.com. Use the SpeedSPEC Code for quick access to the specific web page. Most Diverse and Flexible Line of Coded Magnetic
More informationMaking Hazardous Operations Safe and Productive
NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series
More informationG9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function
Safety Guard Switching Unit CSM DS_E_6_1 A Safety Measure for Hazardous Operations That Does Not Lower Productivity Two functions support two types of application: Auto switching: For applications where
More informationSafety Monitoring Relays
Safety Monitoring Relays Contents Selection Guide I-2 Safety Monitoring Relays G9SA I-6 SR101A I-12 SR103AM I-13 SR104P I-17 SR105E I-17 SR106ED I-21 SR108AD & SR109AD I-18 SR120MP I-21 SR125SMS45 I-22
More informationSafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay
EN 954 SafeC S Safety Relay SafeC S: Narrow construction of only 22.5 mm SafeC S is a sturdy and extremely inexpensive safety relay which impresses with its unusual efficiency and versatility, despite
More informationDatasheet - SLB 200-C04-1R
14.02.2013-17:06:30h Datasheet - SLB 200-C04-1R Safety light barriers / Safety monitoring modules to monitor safety light barriers / SLB 200-C Up to 2 light barrier pairs SLB 200 can be connected 1 safety
More informationRM-2 and RM-2AC. Resource Module Converts Solid-State Outputs to Force-Guided Relay Outputs
esource M- and Module M-ACM- C US C US File No. L9000- escription M- and M-AC esource Module Converts Solid-State s to Force-Guided elay s Converts the solid-state safety and auxiliary outputs of one STI
More informationNokeval. FD100 series. User Manual
Nokeval FD100 series User Manual Contents Document information... 2 FD100A4 and FD100A6 field displays... 3 Power supply connection... 4 Configuring... 5 Specifications... 7 Document information Device
More informationMat Controller ... MC6 Series. Installation and Operating Manual Original Instructions 1 / 888 /
Mat Controller MC6 Series Installation and Operating Manual OMRON Scientific Technologies Inc. Manufacturing and Sales Office 6550 Dumbarton Circle Fremont CA 94555-3605 USA 1 / 888 / 510-4357 Tel: 510/608-3400
More informationPage Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W
Selection Guide Selection Guide PS5R Slim Line PS5R PS3L Operator Interfaces Communication & Networking PLCs NEW Models Appearance Automation Software Page 107 113 118 Housing Plastic Metal Mounting DIN
More informationMachine Safety Switches
Machine Safety Switches Style SI-MAG Series ic Style Switch Features Non-contact safety switches are the best choice for washdown applications; the switch components are sealed and rated NEMA 4X, IEC IP67
More informationonlinecomponents.com
FF-RE59292 Extension Module Instructions for use (pending) (pending) IMPROPER INTALLATION Consult with U and/or European safety agencies and their requirements when designing a machine control, interface
More informationA0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT
A0-10 ANALOG OUTPUT Instruction Manual April 2001 NALOG OUTPUT Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the
More informationXPSMCMDO Digital output pairs expansion modules with screw term
Characteristics 2 Digital output pairs expansion modules with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs
More informationMat Controller MC4 Series
Mat Controller MC4 Series Installation and Operating Manual Scientific Technologies Inc. Optical Sensor Division Manufacturing and Sales Office 6550 Dumbarton Circle, Fremont, CA 94555-3611 Phone 510/608-3400
More informationMC Controllers. MC3, MC4 and MC6 Series Safety Mat Controllers. Description. Safety Mats & Area Guarding. Options MC6 MC3
Safety Mats & Area Guarding MC Controllers MC or full product information, visit www.sti.com. Use the SpeedSPEC Code for quick access to the specific web page. MC, MC and MC Series Safety Mat Controllers
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationDold BH5928 Series 2-Channel Emergency Stop and Safety Gates with Delay
Dold Series 2-Channel Emergency Stop and Safety Gates with Delay -92-61-24-1 Part umber Price Marking Type Voltage Outputs Time Delay -92-61-24-1 2-channel E-STOP / GATE 24 VDC 3.O. time delay positive
More informationES-TN-1H.. E-Stop Safety Modules with Fixed Delay
ES-TN-H.. E-Stop Safety Modules with Fixed Delay Models with fixed delay, ranging from.25 second to 2 seconds Model Models Delay ES-TN-H ES-TN-H2 ES-TN-H3 ES-TN-H4 ES-TN-H7 ES-TN-H8 ES-TN-H9 ES-TN-H ES-TN-H
More informationSeries IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts.
Peak G 15min Handheld Electrostatic Meter Series IZH10 How to Order IZH10 Option Nil H None High-voltage measuring handle Accessories and Option / Part Number for Individual Parts The ground wire and soft
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and
More informationIES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v
IES-0920 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail User Manual v1.00-1206 Preface This manual describes how to install and use the Industrial Ethernet Switch. This switch integrates full wire
More informationExpansion Unit G9SX-EX Safety 2 Instantaneous safety outputs
Flexible Safety Unit / Safety Guard Switching Unit G9SX/G9SX-GS CSM_G9SX_G9SX-GS_DS_E_8_1 Logical Function Adds Flexibility to Various Safety Circuits Be sure to read the Safety Precautions on page 45.
More informationZC Series Zone Monitoring Controllers
ZC Series Zone Monitoring Controllers Installation Instructions MANUAL Reset Controllers Model Description Part Number ZC-1 1 Zone Controller 0421 ZC-2 2 Zone Controller 0422 ZC-3 3 Zone Controller 0423
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches TL8012-S TL8012 For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Versatile Safety Interlock
More informationModels IM-T-9A and IM-T-11A Interface Modules
Models and IM-T-11A Interface Modules Interface Modules for use with a Primary Device Interface Modules provide isolated safety output contacts for a primary safety device (e.g., a safety light screen
More informationPGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY REVISION 3-B-041318 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document
More informationE-Stop Safety Modules with Adjustable Delay
E-Stop Safety Modules with Adjustable Delay Models ES-TN-14H5 with -2 second delay, ES-TN-14H6 with -2 second delay Features Selectable Auto-Reset or monitored Manual Reset. Auto or manual power-up One-
More informationrcc.1081 Installation Instructions
rcc.1081 Installation Instructions Table of Contents Introduction...1 Specifications...2 Mounting...3 Wiring...5 Wiring Method...7 BACnet Network Wiring...8 Setting BACnet Address...9 Setting the BACnet
More informationD2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.
Door Interlock Switch Power Switch with Minimum Contact Gap of 3 mm Offers the minimum contact gap of 3 mm required for power switches as standard equipment. Highly reliable design conforms to European
More informationVI - Safety techniques
VI - Safety techniques In this chapter we discuss some of the more significant and common safety techniques and introduce some of the vocabulary used by safety equipment manufacturers like Honeywell to
More informationPGR-3200 MANUAL INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN
More informationD6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D
D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General
More informationOS3101. Operator Presence Detection in Work Areas with Complex Shapes. Safety Laser Scanner. Ordering Information. Safety/Area.
Laser Scanner / Operator Presence Detection in Work s with Complex Shapes A Type 3 Laser Scanner in compliance with IEC 61496-1/-3. Two patterns of protective and warning area combinations can be set to
More informationDC Outdoor Power Supply/Chargers
DC Outdoor Power Supply/Chargers Installation Guide Models Include: WayPoint3 WayPoint7-2.5A @ 12VDC or 24VDC. - 6A @ 12VDC or 24VDC. - 115/230VAC input. - 115VAC input. WayPoint5 WayPoint7V - 4A @ 12VDC
More informationCompactBlock Guard I/O EtherNet/IP Safety Modules
Installation Instructions CompactBlock Guard I/O EtherNet/IP Safety Modules Catalog Numbers 1791ES-IB8XOBV4, 1791ES-IB16 Topic Page Important User Information 2 North American Hazardous Location Approval
More informationSafety Relay Unit (I/O Unit Type)
Safety Relay Unit (I/O Unit Type) CQM1-SF200/ CS1W-SF200 Same Dimensions as I/O Unit Less Installation Space and Wiring Required Safety Relay Unit that can be used as an I/O Unit for OMRON s CQM1H and
More informationLevel-Lance Model 5400A
Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing
More informationSLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001
SLATE Digital I/O Module R8001D4001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More informationPGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.
More informationSafety Interlock Switches
r Safety Interlock Switches Compact Universal Tongue- Operated Safety Interlock Switch Strong and versatile the compact size of the strong, glass-filled polyester housing can be used in many applications
More informationSix Input Emergency Stop Monitoring Safety Relay
Six Input Emergency Stop Monitoring Safety Relay Model ES-TA-3D1 with DeviceNet CONTENTS Section 1 Product Description 3 Section 2 Emergency Stop Switch 4 Requirements Section 3 Mounting the Control 5
More informationMODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE
INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.
More informationUser Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX
User Manual MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX CE MARKING This equipment complies with the requirements relating to electromagnetic compatibility, EN 55022 class A for ITE, the
More informationXPSMCMMX inputs 2 output pairs expansion module with screw term
Characteristics 8 inputs 2 output pairs expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs
More informationUser Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector
User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector Gigabit Ethernet Switch with PoE+ for Industrial Use Page 2/11 Table of Contents General... 3 Benefits... 3 Front View...
More informationSolid-state Timer H3YN
Solid-state Timer H3YN Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple
More informationASI Systems ML5740A Series
ML5740A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5740A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.
More informationTraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE
TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions
More informationGeneral-Purpose Photoelectric Sensor
General-Purpose Photoelectric Sensor Compact Limit Switch Style with Universal Supply FET output allows for solid state switching of AC or DC Universal AC/DC power supply Choose cable or connector types
More informationPump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters
DESCRIPTION Pump-Down Controller Input Scalable Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters The Model 4052 Pump-Down Controller provides total control for duplex pumping
More informationSolid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)
Solid-state Timer Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple
More informationSITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3
Overview Safety notes 1 SITOP power supply Manual Description, device design, dimension drawing 2 Mounting/removal 3 Mounting position, mounting clearances 4 Installation 5 Technical data 6 Safety, approvals,
More informationSafety Control Relay Product Catalog
Product Catalog Wall Mount for use with Safety Mats Safety Edges Safety Bumpers Safety Sensors 2 wire Safety Sensors 4 wire DIN Rail Mount Intrinsically Safe Explosion Proof Wall Mount Introduction The
More informationXPSMCMDI Input expansion module with screw term
Characteristics 16 Input expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs Number of outputs
More informationKSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-
KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced
More informationCrane Control Class 9004
Catalog 17 CONTENTS Description.....................................................Page Pricing and Ordering Information...................................... 140 Dimensions and Weights............................................
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control
More informationTYPE 4 SAFETY LIGHT CURTAIN EOS4
TYPE 4 SAFETY LIGHT CURTAIN is a compact Type 4 light curtain with competitive performance and innovative features. Its features include: Cross section Minimal cross section - 28 x 30 mm. No blind area
More informationBNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS
BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS Safety Controller Suitable for use with Coded-Magnet Sensor Part Numbers below BNS250... BNS33... BNS303...
More informationSafety Monitoring Relays
Safety Monitoring Relays G9SA G9SA Safety Relay Unit Four kinds of 45-mm wide units are available: A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a two-hand controller.
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 50729 Page of 9 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control
More informationSMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK
SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.com, www.smartscan.com
More informationNE1A/DST1. DeviceNet Safety System
System Omron now offers a DeviceNet compatible Safety System, that can be used 3-ways: as a Standalone controller, as a Safety network expandable with remote I/O blocks, or combined with DeviceNet to form
More informationMain contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible
Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide
More informationUser Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX
User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX Entry Line Fast Ethernet Switch Fast Ethernet Switch for Industrial Use Page 2/11 Table of Contents General... 3 Benefits... 3 Front
More informationS66 Series Electronic Fan Speed Control
FANs 121, 125, 1628.3 Product/Technical Bulletin S66 Issue Date 0918 S66 Series Electronic Fan Speed Control The S66 Series Electronic Fan Speed Control is designed to modulate the speed of single-phase,
More informationMobileView Junction Box
Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard
More informationPower Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number
Standard Series Key features: Wide power range: 7.W-24W Universal input : 7.W-W: 8-264V AC/1-37V DC 1W: 8-2V AC/17-264V AC 24-37V DC (selectable) W, W, 24W: 8-264V AC/11-3V DC Overcurrent/overvoltage protection
More informationSMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
More informationPCI 2 Axis Servo Card
Installation Instructions PCI 2 Axis Servo Card (Catalog Number 1784-PM02AE) This manual provides the instructions for installing the PCI 2 Axis Servo card (1784-PM02AE) in a PC computer using the NT operating
More informationSignamax Connectivity Systems
Signamax Connectivity Systems Hardened Ethernet Switch Model -065-7405TB 065-7408ATB 065-74091FXSTTB 065-74091FXSCTB U S E R S G U I D E 1 Quick Start Guide Hardened Ethernet Switch This quick start guide
More informationSeries Panel Mounted Control Devices
E_Master2012.qxd:NEW_E_Master_temp.qxd 1/27/12 4:28 PM Page 1 Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2"
More informationMSR178DP. Description. Features. Specifications
MSR178DP Description The MSR178DP is a multi-function time-delay relay for use in safety circuits. It can be configured by the user to perform on-delay, offdelay or single-pulse modes. It is used for applications
More information7511 / / / 711 / / 731 / Preset 27
22 Timers Timers Electronic 23 7511 / 3410 23 6320 / 720-6300 24 ElectRo-MeCH 25 710 / 711 / 720 25 722 / 731 / 732 26 Preset 27 7932 27 Electronic 23 7511 Series 8 digit self powered LCD electronic timer
More informationSafety Light Curtains GuardShield Remote Teach
Specifications Presence Sensing Safety Devices Description The system provides a remote means of changing a fixed blanking configuration within the GuardShield safety light curtain. This keyswitch box
More informationThread length (overall length) material
Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive
More informationTecnología en Electrónica y Control SRL Ficha Técnica
Tecnología en Electrónica y Control SRL Ficha Técnica Relé de seguridad Tecnología en Electrónica y Control SRL Oficina Central Wüthrich 949 San Carlos Centro (S3013DES) / Santa Fe / Argentina Tel./Fax/Líneas
More informationETD-BL-1T-OFF-CC- 10S
Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time
More informationThread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm
Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information
More informationSINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA
SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA SUPRESOR PRINCIPAL DE 300 KA. ST-SMLA 3N4 TRANSIENT VOLTAGE SURGE SUPPRESSORS. PROTECTION AGAINST
More informationVC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide
Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index
More information