1 US File No. LR9000 Description BeamSafe 0 m (00 ft.) range Four possible transmit codes eliminate crosstalk from multiple units in the same area II Long-Range, Single-Beam Safety ontrol Signal strength indicator and integral Gun Sight allow easy installation No interconnecting cables required, which speeds long-range installations Three models available: Relay output with 4 VD power input Relay output with 8 to 0 V power input Solid-state output with 4 VD power input Switch-selected utomatic Start or Start/Restart Interlock operation Lens heater Shown here with optional quick-disconnect cable kit. The BeamSafe II is a long-range single-beam safety control designed for perimeter and access guarding. Diverse redundant microprocessor design provides safe, control reliable operation. BeamSafe II system consists of one transmitter and one receiver. No interconnecting cables or separate control enclosure are required. Mounted on the receiver, four separate visible indicators provide instant information on system clear, blocked or interlocked status as well as signal strength. dditional diagnostic indicators on the receiver provide codes to assist with troubleshooting. Output options include redundant solid-state or force-guided relays located in the receiver. Immunity to weld flash and ambient light are enhanced by coding the infrared beam. This feature also eliminates interference from other BeamSafe II units installed in close proximity. tight beam angle reduces problems associated with reflective surfaces. The Beamsafe II s built-in lens heater is effective in environments where condensation may form on the transmitter or receiver lens. djustable mounting brackets allow easy alignment Designed in accordance with IE49, EN94- and NSI B.9-00 Go to the Engineering Guide For in-depth information on safety standards and use. 4 US Tel. /888/0-47 anada Tel. /8/98-7

2 pplications Perimeter Guarding Shown here with one transmitter and receiver. Mirrors are used to form two beams and also turn corners. transmitter receiver floor to 9 ft 0. to 8 m in 400 mm in 900 mm Long-Range Perimeter Guarding Two transmitter/receiver pairs using two mirrors and Omron STI mounting stands to direct the beam around a corner. transmitter transmitter floor to 7 ft 0. to m in 400 mm in 900 mm receiver receiver Double Bounce This configuration guards access to hazardous work cells. One transmitter and receiver combined with two Omron STI 4 in. mirrors and mounting brackets. transmitter receiver floor to 7 ft 0. to in 400 mm in 900 mm 4 mirror 4 mirror Specifications Performance Protected Height: Single Beam Operating Range: 0. to 0 m ( to 00 ft.) Beam Diameter: mm (. in.) Maximum Response Time: <0.0 seconds for all models D Models Input Power: 4 V ±0% (negative ground) Receiver/Relay Output: 0.4 Max Receiver/SS Output: 0.80 Max Transmitter: 0.7 Max Models Input Power: 00 to 0 V ±0%, 0/0 Hz; Receiver V: V Receiver 0 V: V Transmitter V: 0. V Transmitter 0 V: 0 V Effective perture ngle:. maximum half angle Frequency Selection: 4 non-interfering codes, all models Diagnostics: Built-in diagnostic indicators Output: Relay Output Version: Two relays with force-guided contacts, NO rated 4 at V, 00 W switched power (.0 kv). D Loads are limited to 00 V maximum. Estimated mechanical life is 0,000,000 operations. Electrical life is typically,000,000 operations at 00 V. uxiliary Monitoring Relay: 400 V /D maximum, 0. ; total power 80 mw maximum. Solid-State Output Version: Two safety solid-state relay outputs. Each output sources (PNP) up to 0. at 4 VD. onstruction: Polyester powder-painted aluminum body. nodized aluminum end-caps. Operating Temperature: 0 to ( to F) Protection ategory: IP; NEM 4 gencies: Designed in accordance with IE 49, type 4 and UL/S requirements. Specifications are subject to change without notice. US Tel. /888/0-47 anada Tel. /8/98-7

3 R R R BeamSafe II Dimensions mm/in. BeamSafe II, Relay Output Version 0. c B ref. mounting holes (4) for lternte rer mounting front VieW mounting BrcKet SUrfce mtg "footprint" DimenSiOnS.9.0 r (X) BeamSafeII ref. SiDe VieW BeamSafe ii, relay Output Version Unit length Dims c receiver c transmitter Dc receiver B c lternte rer cble entry BeamSafeII Receiver f f BcK/rer VieW SlOtS for t-nuts (X) c.9.4 l 0.7 Di. Dc transmitter top VieW BOttOm VieW Dimensions: mm in ± 0. ± 0.0 DJUStBle mounting BrcKet BeamSafe II, Solid-State Output Version, Tranmitter and Receiver This drawing is available in D format at ref mounting holes (4) for lternte rer mounting BeamSafeII 8. ref. BeamSafeII Receiver lternte rer cble entry.4.00 front VieW SiDe VieW BcK/rer VieW mounting BrcKet SUrfce mtg "footprint" DimenSiOnS r (X) c l.0 0. (X) Ø top VieW SlOtS for t-nuts BOttOm VieW DJUStBle mounting BrcKet mm ± Dimensions: 0. Go into the ± 0.0 Engineering Guide For in-depth information on safety standards and use. US Tel. /888/0-47 anada Tel. /8/98-7

4 Wiring two normally Open contacts c Voltage connections BSrc J J7 earth/ground Output Output B uxiliary monitor relay (non Safety Output) (n.c.) Start to 0 Vc mpce mpce no external voltage is to be applied to terminals &. Damage to unit will occur. mpce mpce to machine control Stop circuit Wrning: rc suppression devices should only be installed across the coils of the machine control relays. never install rc Suppression devices directly across the control output contacts of the BeamSafe. n arc suppression device installed across the contacts may fail with a short circuit and will result in an unsafe condition. these relay contacts must be forceguided contacts. User supplied over current protection, 4 max. normally Open/normally closed connection Diagram BSrc 00 to 0 Vc mpce mpce earth/ground 7 8 to machine control Stop circuit J J7 Output Output B uxiliary monitor relay (non Safety Output) (n.c.) Start mpce mpce no external voltage is to be applied to terminals &, Damage to unit will occur. Wrning: rc suppression devices should only be installed across the coils of the machine control relays. never install rc Suppression devices directly across the control output contacts of the BeamSafe. n arc suppression device installed across the contacts may fail with a short circuit and will result in an unsafe condition. these relay contacts must be forceguided contacts. User supplied over current protection, 4 max. US Tel. /888/0-47 anada Tel. /8/98-7 7

5 Wiring (continued) two normally Open contacts Dc Voltage connections (Solid-State Output model) BSrc4 J Sourcing earth/ground Output Output B Start (n.c.) Signal return VDc two normally Open contacts 4 VDc Voltage connections mpce mpce no external voltage is to be applied to terminals 4 & ; Damage to unit will occur. mpce mpce to machine control Stop circuit Wrning: rc suppression devices should only be installed across the coils of the machine control relays. never install rc Suppression devices directly across the control output contacts of the BeamSafe. n arc suppression device installed accros the contacts may fail with a short circuit and will result in an unsafe condition. these relay contacts must be force guided contacts. if load is less than 0 m a resistor must be installed across the load. BSr4 4 VDc mpce mpce J earth/ground to machine control Stop circuit J J Output Output B uxiliary monitor relay (non Safety Output) (n.c.) Start 4 4 mpce mpce no external voltage is to be applied to terminals 4 &. Damage to unit will occur. Wrning: rc suppression devices should only be installed across the coils of the machine control relays. never install rc Suppression devices directly across the control output contacts of the BeamSafe. n arc suppression device installed accros the contacts may fail with a short circuit and will result in an unsafe condition. these relay contacts must be forceguided contacts. User supplied over current protection, 4 max. Go to the Engineering Guide For in-depth information on safety standards and use. 8 US Tel. /888/0-47 anada Tel. /8/98-7

6 ccessories mm/in. Front Surface Glass or Stainless Steel Mirror mir4-fg and mir4-ss Brackets mir4bkt mirror StinleSS Steel Or glss mirror SUPPOrt BlOcK mirror StnD PiPe 8..0 mounting tbs (4 PlceS) BSmK Or US Tel. /888/0-47 anada Tel. /8/98-7 9

7 ccessories mm/in. (continued) dapter Kit esbkt (includes DPterS OnlY) DPter lcmk-4 mirror min DPter Laser lignment Tool BSL Laser Level Unit Target lip BEMHEK BeamSafe II BeamSafe II Laser Mounting daptor Go to the Engineering Guide For in-depth information on safety standards and use. 0 US Tel. /888/0-47 anada Tel. /8/98-7

8 Ordering Model No. Description BSX4 Transmitter, 4 VD BSX Transmitter, 8 to 0 V, 0/0 Hz BSX4 Transmitter, 4 VD, ompact Size (This is not compatible with QDX and QDR series connectors) BSR4 Receiver, 4 VD, Relay Output BSR Receiver, 8 to 0 V, 0/0 Hz, Relay Output BSR4 Receiver, 4 VD, ompact Size, Solid-state Output (This is not compatible with QDX and QDR series connectors) ccessories Description MIR4-FG 4 in. mirror for use with MIR4BKT-Front Surface Glass MIR4-SS 4 in. mirror for use with MIR4BKT-Stainless Steel MIR4BKT Bracket for mounting above mirrors at 4 angles for use in double bounce applications (kit mounts one mirror) BSMK Bracket kit. llows mounting of one BeamSafe II transmitter and one BeamSafe II receiver to Omron STI mounting stands ESBKT dapter kit. llows mounting of BSMK and MIR4BKT components to extruded aluminum framing systems and other flat surfaces. MIRS-04 4 ft. stand for mounting mirrors and BeamSafe II units MIRS-0 ft. stand for mounting mirrors and BeamSafe II units QDR- ft., -conductor receiver cable, with quick-disconnect socket QDR-0 0 ft., -conductor receiver cable, with quick-disconnect socket QDR- ft., -conductor receiver cable, with quick-disconnect socket QDX- ft., -conductor transmitter cable, with quick-disconnect socket QDX-0 0 ft., -conductor transmitter cable, with quick-disconnect socket QDX ft., -conductor transmitter cable, with quick-disconnect socket BSL Laser lignment Tool Safety Standards and Precautions The BeamSafe II meets applicable OSH, NSI and RI standards and was designed in accordance with IE49, DIN EN 000 and EN 94-. Only use the BeamSafe II on machinery that stops consistently and immediately anywhere in its cycle or stroke. Never use a BeamSafe II on a full-revolution clutched press or machine. The BeamSafe II is a single optical beam, not a curtain of light. Therefore it is not designed for use as a point-of-operation device. If one or more BeamSafe II systems do not protect all access to the hazardous machine area, the unprotected access must be guarded by fencing, barriers or other appropriate methods. The purchaser, installer and employer are responsible for meeting all appropriate laws, rules and regulations relating to the proper use, installation, operation and maintenance of this control and the guarded machine. For information on safety light curtain accessories, see page D84 US Tel. /888/0-47 anada Tel. /8/98-7

Guard Mode. Machine Test Signal. MPCE Checking. Remote Function Access. Status and Diagnostic indicator lights visible on controller enclosure lid

Guard Mode. Machine Test Signal. MPCE Checking. Remote Function Access. Status and Diagnostic indicator lights visible on controller enclosure lid MicroSafe File No. LR90200 Description MicroSafe Ultra-compact transmitter and receiver 1 x 1.25 inches (25 x 32 mm) 0.8 inch (20 mm) resolution 29.5 foot (9 m) range Protected heights from 8 to 48 inches

More information

No cable required between transmitter and receiver. Exact Channel Select. Floating Blanking. Choice of operating modes.

No cable required between transmitter and receiver. Exact Channel Select. Floating Blanking. Choice of operating modes. MiniSafe File No. LR90200 Description MiniSafe 0.75 inch (19mm) resolution 65 foot (20 meter) range Protected heights from 10 to 55 inches (263 to 1394mm) Compact size 1.4 x 2 inches (35 x 50mm) Simple

More information

OptoFence. OptoFence OF OF safety light curtains. Description

OptoFence. OptoFence OF OF safety light curtains. Description File No. LR90200 Description OptoFence OF4600-50 2.0 inch (53mm) resolution 80 foot (24 meter) range Four protected heights available: 27, 41, 55 and 69 inches (700, 1046, 1394 and 1741mm) Compact size

More information

Remote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4)

Remote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4) File no. LR90200 Description mats and edges MC3, MC4 and Safety Mat Controllers Both metal enclosure and DINrail mount models available Control reliable Remote access to status, test and reset functions

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Safety Light Curtains MP2100 MP2100 For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. MiniProtect Light Curtains Resolution:

More information

Safety Mats & Area Guarding

Safety Mats & Area Guarding Safety Mats & Area Guarding MC Controllers MC MC, MC and MC Series Safety Mat Controllers The MC Series safety mat controllers are used in conjunction with a four-wire, normally open, safety mat where

More information

MiniSafe MS4600 MS4600. safety light curtains. Description

MiniSafe MS4600 MS4600. safety light curtains. Description Rev. 11.07 MS4600 C US File No. LR90200 C R US escription MiniSafe MS4600 Resolution: 14 mm (0.55 in.), 19 mm (0.75 in.) or 30 mm (1.18 in.) resolution Range: 7.5 m (25 ft.) range for the 14 mm resolution

More information

LIGHT SCREENS Catalog Safety Supply Maximum Type Model Page Category Resolution Voltage Range. Page Point Systems. Page 42 4.

LIGHT SCREENS Catalog Safety Supply Maximum Type Model Page Category Resolution Voltage Range. Page Point Systems. Page 42 4. Catalog Safety Supply Maximum Type Model Page Category Resolution Voltage Range Standard Systems 14 & 30 mm Cascade Systems Page 20 4 14 & 30 mm 24V dc 18 m Grid & Point Systems 300 to 584 mm (beam spacing)

More information

Optional integrated laser alignment facilitates simple, fast alignment for long distances or when using mirrors. Stone production Automotive industry

Optional integrated laser alignment facilitates simple, fast alignment for long distances or when using mirrors. Stone production Automotive industry Technical data overview Operating range 0.5 20 m 15 70 m Number of beams, type dependent 2 8 Beam distance, type dependent 300 mm, 400 mm, 450 mm, 500 mm, 600 mm Type according to EN 61 496 Type 4 Enclosure

More information

Safety Light Curtains GuardShield Remote Teach

Safety Light Curtains GuardShield Remote Teach Specifications Presence Sensing Safety Devices Description The system provides a remote means of changing a fixed blanking configuration within the GuardShield safety light curtain. This keyswitch box

More information

8000 Series: Installation Supplement R2-1-12

8000 Series: Installation Supplement R2-1-12 8000 Series: Installation Supplement R2-1-12 Smartscan Incorporated, 33083 Eight Mile Road, Livonia MI 48152 Tel: (248) 477-2900 Fax: (248) 477-7453 Web: www.smartscaninc.com SMARTSCAN INCORPORATED Livonia,

More information

F3SJ-A F3SJ-A. Safety Light Curtain. safety light curtain that. Options. software. The F3SJ-A system is a fullfeatured

F3SJ-A F3SJ-A. Safety Light Curtain. safety light curtain that. Options. software. The F3SJ-A system is a fullfeatured C R US Options n Handheld setting console n S manager programming software n F3SP/F3SX Safety Controller n Weld shields n IP67 enclosures n Multiple mounting options n escription F3SJ- Safety Light Curtain

More information

T4HD: Installation Supplement R8.1.13

T4HD: Installation Supplement R8.1.13 THD: Installation Supplement R8.. Smartscan Incorporated 08 Eight Mile Road Livonia MI 8 Tel: (8)77-900 Fax: (8) 77-7 Web: www.smartscaninc.com Smartscan Incorporated Livonia, Michigan THD The use of this

More information

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power

More information

C5 Series Stainless Steel Photoelectric

C5 Series Stainless Steel Photoelectric C5 Series Stainless Steel Photoelectric Part Number Sensing Range M5 (5 mm) stainless steel - DC 14 models available Diffuse and through-beam styles Long operating distances Compact stainless steel housing

More information

F3SL. Safety Light Curtain for Long Distance Detection

F3SL. Safety Light Curtain for Long Distance Detection Safety Light Curtain for Long Distance Detection CSM DS_E_3_1 20-m long-distance detection. Safety light curtain (Type 4) is ideal for detection of intrusion of human bodies in large machines and conveyor

More information

Compact Coded Magnetic Safety Interlock Switch and Control Units

Compact Coded Magnetic Safety Interlock Switch and Control Units C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch

More information

SAFETY & MESUREMENT SERIE SG-BODY BIG

SAFETY & MESUREMENT SERIE SG-BODY BIG safety BODY PROTECTION LIGHT CURTAINS SERIE SG-BODY BIG reflector The new SG BODY BIG safety light curtain series thanks to its new housing together with the innovative design optical-electronic platform

More information

EZ-SCREEN. Full View L AUTOCAD, STEP, IGES & PDF. Yellow Painted Aluminum. Trip 2 PNP OSSD. Trip

EZ-SCREEN. Full View L AUTOCAD, STEP, IGES & PDF. Yellow Painted Aluminum. Trip 2 PNP OSSD. Trip Type 2 Point-of-Operation A low-cost solution is suited to lower-risk applications where the result of an accident is only a slight injury such as a bump, bruise, knockdown or trapping (but not crushing),

More information

Series 28 Universal Sensors

Series 28 Universal Sensors Series 8 Universal Sensors Diffuse Mode with Background Suppression See pages 548-553 Features: Sharp sensing range cut-off Choice of infrared, visible red and laser light sources Sensing Range: 400 mm,

More information

Photoelectric Sensors E3F2

Photoelectric Sensors E3F2 Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel

More information

ML17 Series Tru-Vue TM Sensors

ML17 Series Tru-Vue TM Sensors ML7 Series Tru-Vue TM Sensors Diffuse Mode with Background Suppression See page 44 Features: Ver low color sensitivit Tamper-proof housing with no eternal adjustments Sensing Range: 5 mm Output: 4-in-

More information

MLV41 Series Miniature Sensors

MLV41 Series Miniature Sensors MLV41 Series Miniature Sensors Diffuse Mode with Background Suppression See pages 5-53 Features: Etended sensing range compared to similar housings High insensitivity to target color Sensing Range: 35

More information

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.com, www.smartscan.com

More information

Universal Tongue-Operated Safety Interlock Switch

Universal Tongue-Operated Safety Interlock Switch Rev. 12.07 C R US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1 UL and C-UL listed, B approved T12 Universal Tongue-Operated Safety Interlock Switch Strong and versatile the compact size of the strong,

More information

Table of Contents LED Machine Lighting - Pg. 1 Automation & Sensing - Pg. 27 Safety - Pg. 255 Switching & Controls - Pg. 449 Index - Pg.

Table of Contents LED Machine Lighting - Pg. 1 Automation & Sensing - Pg. 27 Safety - Pg. 255 Switching & Controls - Pg. 449 Index - Pg. Safety Selection Guide... 430 Type 2 SG2 Series (Basic & Extended Models)... 431 Type 4 SG4 Series... 435 Mounting Brackets and Accessories... 439 www.idec.com/safety Light Curtains Overview XW Series

More information

XUSL4E14F046N XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm

XUSL4E14F046N XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm Characteristics XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm Main Range of product Nov 18, 2017 Preventa Safety detection Product or component type Safety light curtain type

More information

SMARTSCAN INFORMATION

SMARTSCAN INFORMATION SMARTSCAN INFORMATION SL4 (014) SERIES SAFETY LIGHT CURTAINS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.co.uk,

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

Miniature Inductive Prox TL-W

Miniature Inductive Prox TL-W Miniature Inductive Prox Subminiature, Flat-Pack DC Sensor Fits Tight Spaces Watertight construction conforms to IP67 Space-saving mounting area, as small as 10 x 27 mm ( 0.39 x 1.06 in), is ideal for

More information

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes. 1123 PHOTO PHOTO PARTICUR Type Edge Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.1593~ guide... P.1021~ General precautions... P.1595 Conforming to FDA regulations

More information

Universal Safety Photo Eye UL MONITORED DEVICE

Universal Safety Photo Eye UL MONITORED DEVICE IRB-MON Universal Safety Photo Eye UL325-2016 MONITORED DEVICE Operating Instructions CAUTIONS AND WARNINGS This product is an accessory or part of a system. Always read and follow the manufacturer s instructions

More information

IEC Power Control Contactors and Contactor Assemblies

IEC Power Control Contactors and Contactor Assemblies IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,

More information

Cat No PJV-KA-C. Expandable Safety Light Curtain PJ-V Series ANSI OSHA CATEGORY 4

Cat No PJV-KA-C. Expandable Safety Light Curtain PJ-V Series ANSI OSHA CATEGORY 4 Cat No PJV-KA-C Expandable Safety Light Curtain PJ-V Series OSHA C US ANSI CATEGORY In-house System Configuration Keyence's revolutionary modular system permits in-house custom configurations.this unique

More information

F3ET Lightcurtain in robust aluminium housing

F3ET Lightcurtain in robust aluminium housing Lightcurtain in robust aluminium housing FET Lightcurtain in robust aluminium housing The FET lightcurtains provide a reliable area monitoring in a robust housing. The M2 -pin connectors and optical synchronisation

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500

More information

XUSL4E14F121N XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm

XUSL4E14F121N XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm Characteristics XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm Complementary Detection system Response time Kit composition [EAA] effective aperture angle Emission Main Range

More information

E3FS. Connect up to 4 sets of E3ZS/E3FS per B1 Module for F3SX Safety Controller

E3FS. Connect up to 4 sets of E3ZS/E3FS per B1 Module for F3SX Safety Controller Single-beam Safety Sensor Type 2 Safety Photoelectric Sensor for Hazardous Gaps in Machines Note: Be sure to read the Safety Precautions International standards: IEC6496- (type 2 ESPE) IEC6496-2 (type

More information

Capacitive Proximity Sensor E2K-C

Capacitive Proximity Sensor E2K-C 3 to 5 mm, adjustable Sensing Supply voltage Output 9 to 5AC, 5/6 Hz 1 to 4DC ma ma, NPN or PNP Capacitive Proximity Sensor Cylindrical Sensor Offers Adjustable Detecting Distance Permits non-contact detection

More information

IDEC SE4D Safety Light Curtains

IDEC SE4D Safety Light Curtains I S4 Safety Light urtains Safety - when & where you need it most Switches Unlimited, Technical ept. Phone: 800-1-0487 * ax: 7-67-6370 S4 Safety Light urtains Light curtains are used to keep production

More information

TYPE 4 SAFETY LIGHT CURTAIN JANUS.

TYPE 4 SAFETY LIGHT CURTAIN JANUS. TYPE 4 SAFETY LIGHT CURTAIN JANUS http://muting.reer.it JANUS The Janus type 4 family of safety light curtains is the ideal solution for the protection of a vast number of high-risk industrial applications,

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

MACHINE-GUARD & PERIMETER-GUARD Systems

MACHINE-GUARD & PERIMETER-GUARD Systems MACHINE-GUAD and PEIMETE-GUAD Systems MACHINE-GUAD & PEIMETE-GUAD Systems System Overview............................ 122 Selection of Components...................... 123 Emitters & eceivers.........................

More information

SMARTSCAN INFORMATION

SMARTSCAN INFORMATION SMARTSCAN INFORMATION SS-1K+ AUG05 LIGHT CURTAINS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.com, www.smartscan.com

More information

Presence Sensing Safety Devices

Presence Sensing Safety Devices Presence Sensing Devices GuardShield POC Type 4 440L Point of Operation Control (POC) for finger or hand protection Heavy-duty IP65 housing Large operating range 0.3 6 m (0.98 52.49 ft) Dip switch selectable

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

Energetic diffuse reflection light scanner. Dimensioned drawing

Energetic diffuse reflection light scanner. Dimensioned drawing Energetic diffuse reflection light scanner Dimensioned drawing We reserve the right to make changes 93_c3gb.fm Part No. 51 1168 1-3 V DC 5 17mm 1mm Infrared light Background suppression through appropriate

More information

Capacitive Proximity Sensor E2K-X

Capacitive Proximity Sensor E2K-X Sensing Supply voltage Output 90 to 0 VAC, 0/60 z to 30 VDC 00 ma, 8, 1 mm 00 ma NPN or PNP Capacitive Proximity Sensor Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact

More information

General-Purpose Photoelectric Sensor

General-Purpose Photoelectric Sensor General-Purpose Photoelectric Sensor Compact Limit Switch Style with Universal Supply FET output allows for solid state switching of AC or DC Universal AC/DC power supply Choose cable or connector types

More information

Contents. Part no.: MLC500T Safety light curtain transmitter

Contents. Part no.: MLC500T Safety light curtain transmitter Part no.: 68000307 MLC500T30-750 Safety light curtain transmitter Figure can vary Contents Technical data Suitable receivers Dimensioned drawings Electrical connection Circuit diagrams Operation and display

More information

Photoelectric Sensor

Photoelectric Sensor Sensing Supply Voltage Output 3m 1.cm,2m 10cm 2 to 20 VAC, 0/60 Hz to200ma, 20 VAC 100 ma, 2 VDC Photoelectric Sensor Threaded Cylindrical M1 Size Sensors with Built-in Amplifier Chemical resistant, ABS

More information

Basic Series 18 mm Diameter Cylindrical Sensors

Basic Series 18 mm Diameter Cylindrical Sensors Diffuse Mode See pages 384-385 Features: Light on/dark on mode determined by wiring Adjustable sensitivity Sensing Ranges: 2 mm, 5 mm Outputs: NPN, PNP Thru-Beam Mode See pages 387-388 Features: Laser

More information

GuardShield TM Safe 2

GuardShield TM Safe 2 Operation Manual GuardShield TM Safe 2 Safety Light Curtain help protect personnel working on or near machinery. provide 2 3 Content 1. Approvals and Conformity 4 2. Introduction 5 2.1. System design 5

More information

RM-2 and RM-2AC. Resource Module Converts Solid-State Outputs to Force-Guided Relay Outputs

RM-2 and RM-2AC. Resource Module Converts Solid-State Outputs to Force-Guided Relay Outputs esource M- and Module M-ACM- C US C US File No. L9000- escription M- and M-AC esource Module Converts Solid-State s to Force-Guided elay s Converts the solid-state safety and auxiliary outputs of one STI

More information

EM-F-7G Safety Extension Module

EM-F-7G Safety Extension Module EM-F-7G Safety Extension Module One-channel control with four safety output channels Features Safety Extension Module provides additional safety outputs for a Primary Safety Device (for example, an E-stop

More information

ML20 Series Long-Range Miniature Sensors

ML20 Series Long-Range Miniature Sensors Diffuse Mode See pages 486-487 Features: Cross-talk immune for 2 units Divergent beam versions available Sensing Ranges: mm, 1 m Output: NPN, PNP Thru-Beam Mode See page 489 Features: Alignment in lens

More information

Safety light beam Spot

Safety light beam Spot Safety light beam is a light beam mainly used for body detection. It consists of a transmitter and a receiver. Infrared light is sent from the transmitter to the receiver and when the light beam is interrupted

More information

Retro-reflective photoelectric sensors. Dimensioned drawing. Receiver Transmitter Optical axis LED yellow 90 turning connector. Electrical connection

Retro-reflective photoelectric sensors. Dimensioned drawing. Receiver Transmitter Optical axis LED yellow 90 turning connector. Electrical connection IPRK 8 Retro-reflective photoelectric sensors Dimensioned drawing 0.05 8m A 2 LS A²LS - active suppression of extraneous light Integrated AS-i slave M12 turning connector or cable connection Visible red

More information

OS3101. Operator Presence Detection in Work Areas with Complex Shapes. Safety Laser Scanner. Ordering Information. Safety/Area.

OS3101. Operator Presence Detection in Work Areas with Complex Shapes. Safety Laser Scanner. Ordering Information. Safety/Area. Laser Scanner / Operator Presence Detection in Work s with Complex Shapes A Type 3 Laser Scanner in compliance with IEC 61496-1/-3. Two patterns of protective and warning area combinations can be set to

More information

Adjustable Capacitive Prox E2K-C

Adjustable Capacitive Prox E2K-C Adjustable Capacitive Prox Cylindrical Sensor Offers Adjustable Detecting Distance Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

F3S-B. Safety Design for Category 2. Suitable for Detecting Human Bodies in a Dangerous Area. Safety Light Curtain. Features

F3S-B. Safety Design for Category 2. Suitable for Detecting Human Bodies in a Dangerous Area. Safety Light Curtain. Features Safety Light Curtain Suitable for Detecting Human Bodies in a Dangerous Area Safety Design for Category 2. Features The is a type 2 Safety Light curtain intended to be used as or with the safety related

More information

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C r Safety Interlock Switches MA Series MA Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic to satisfy most application

More information

PRODUCT SPECIFICATION. PC Board Relays. Series.

PRODUCT SPECIFICATION. PC Board Relays. Series. PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

SMARTSCAN INFORMATION

SMARTSCAN INFORMATION SMARTSCAN INFORMATION SS 1K+ August 07 LIGHT CURTAINS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.com, www.smartscan.com

More information

ML17 Series Tru-Vue TM Sensors

ML17 Series Tru-Vue TM Sensors ML7 Series Tru-Vue TM Sensors Diffuse Mode with Background Suppression See page 44 Features: Ver low color sensitivit Tamper-proof housing with no eternal adjustments Sensing Range: 5 mm Output: 4-in-

More information

Safety Light Grid Orion2 Extended

Safety Light Grid Orion2 Extended Safety Light Grid Orion Extended Orion Extended is a compact light grid for access protection in muting applications. The light grid has -4 beams and is intended for body detection. Cost effective solution

More information

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-MON UNIVERSAL SAFETY PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales

More information

Optimum sensing capability for LCD manufacturing

Optimum sensing capability for LCD manufacturing SENSORS FOR Glass Substrate Detection Sensor Amplifier-separated FX-301-F FT-F9 FD-F7 EX-F70/F60 HD-T1 M FD-L3 Reliable detection of glass substrates Its unique optical system enables detection of transparent

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

Magnetically Actuated Safety Interlock Switches

Magnetically Actuated Safety Interlock Switches Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,

More information

Making Hazardous Operations Safe and Productive

Making Hazardous Operations Safe and Productive NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series

More information

Datalogic - SG4-Body BIG muting

Datalogic - SG4-Body BIG muting products Machine/Safety Safety light barriers Body Datalogic - SG4-Body BIG muting Body protection (2, 3 and 4 beam), Type 4, PL e Advanced Muting functions integrated Range 0.5-60 m WWW.OEM.CO.UK, INFORMATION@UK.OEM.SE,

More information

XUSL4E2BB051L XUSL type 4 - Body protection - Long sensing range 510 mm

XUSL4E2BB051L XUSL type 4 - Body protection - Long sensing range 510 mm Characteristics XUSL type 4 - Body protection - Long sensing range 510 mm Complementary Detection system Response time Kit composition [EAA] effective aperture angle Emission Main Range of product Product

More information

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30 Sensing distance Supply voltage Output 4 mm 8 mm 12 to 24 VDC 100 to 220 VAC 200 ma max. 100 ma max. Proximity Sensor Detects Objects without Being Influenced by Aluminum and Cast Iron Cut Chips Sense

More information

XUSL2E30H166N XUSL type 2 Hand protection - Std sensing range - Hp = 1660mm, R=30mm

XUSL2E30H166N XUSL type 2 Hand protection - Std sensing range - Hp = 1660mm, R=30mm Characteristics XUSL type 2 Hand protection - Std sensing range - Hp = 1660mm, R=30mm Main Range of product Mar 09, 2017 Preventa Safety detection Product or component type Safety light curtain type 2

More information

42JS & 42JT VisiSight

42JS & 42JT VisiSight JS & JT VisiSight mm Rectangular General Specifications Certifications culus Listed and CE Marked for all applicable directives 7-Encoders PHOTOSWITCH Photoelectric Shock g with ms pulse duration, meets

More information

F3EM Measuring lightcurtain in robust aluminium housing

F3EM Measuring lightcurtain in robust aluminium housing Measuring lightcurtain in robust aluminium housing F3EM Measuring lightcurtain in robust aluminium housing The F3EM provides easy to install and set up height and profile measurement. The analog output

More information

Wide-beam Divergent Mode Remote Sensor. Wiring rules

Wide-beam Divergent Mode Remote Sensor. Wiring rules LP400WB Wide-beam Divergent Mode Remote Sensor The LP400WB is a wide-beam divergent proximity-mode remote sensor which is very useful for sensing small or irregularly shaped or transparent/translucent

More information

B-Series Photo-Electric Light Curtain Systems

B-Series Photo-Electric Light Curtain Systems Release 6/2011 Ver. 3.2 B-Series Photo-Electric Light Curtain Systems Technical Manual WARNING Tapeswitch photo-electric safety systems are intended to protect operators working at or near dangerous machinery.

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

Light Curtains. Type 4 SG4. Type 4 SG4 Series. 468

Light Curtains. Type 4 SG4. Type 4 SG4 Series. 468 Type 4 SG4 Type 4 SG4 Series Overview Finger Protection Hand Protection XW Series E-Stops Interlock Switches Type 4 SG4 features: Integrated light curtain for Finger Protection or Hand Protection Operating

More information

Versatile Safety Interlock Switch with Guard Door Locking

Versatile Safety Interlock Switch with Guard Door Locking R Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved Versatile Safety Interlock Switch with Guard Door Locking High locking force of 450 pounds locks guard door shut until

More information

TYPE 4 SAFETY LIGHT CURTAIN EOS4

TYPE 4 SAFETY LIGHT CURTAIN EOS4 TYPE 4 SAFETY LIGHT CURTAIN is a compact Type 4 light curtain with competitive performance and innovative features. Its features include: Cross section Minimal cross section - 28 x 30 mm. No blind area

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL325-2016 MONITORED DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com Technical Support:

More information

Product description. At a glance. performance in a metal housing coating available Precise autocollimation optics. sensors

Product description. At a glance. performance in a metal housing coating available Precise autocollimation optics. sensors -2 Laser Small photoelectric sensors High-performance photoelectric sensor family with laser optics Product description At a glance performance in a metal housing coating available Precise autocollimation

More information

GuardShield TM Micro400

GuardShield TM Micro400 Operation Manual GuardShield TM Micro400 Safety Light Curtain GuardShield Micro400 Operation Manual 2 Operation Manual GuardShield Micro400 Conditions required for proper use of the GuardShield Safety

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A CSM_ES-A_DS_E Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection

More information

Slot Style Photoelectric Sensors

Slot Style Photoelectric Sensors HPV Series GL Series Slot Style Photoelectric Sensors FE5V Series FE8V Series GL Series See pages 622-623 Useful for edge detection and end of travel applications Simplified thru-beam mounting and beam

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. R Safety Interlock Switches TL8012-S TL8012 For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Versatile Safety Interlock

More information

Miniature Inductive Prox TL-W

Miniature Inductive Prox TL-W Miniature Inductive Prox Subminiature, Flat-Pack DC Sensor Fits Tight Spaces Watertight construction conforms to IP67 Space-saving mounting area, as small as 10 x 27 mm ( 0.39 x 1.06 in), is ideal for

More information

Number of optical axis

Number of optical axis Ultra-flat multi-beam sensor for elevators F3E Ultra-flat 9 mm shape for easy design-in in elevator constructions Highest ambient light immunity (200,000 lux) for installations with direct sunlight exposition

More information

SAFETY LIGHT CURTAINS & BEAMS SELECTION GUIDE

SAFETY LIGHT CURTAINS & BEAMS SELECTION GUIDE SAFETY LIGHT CURTAINS & BEAMS SELECTION GUIDE Series Description Range Page SLB 200 Safety Category 2 Light Beam 4m 282 SLB 400 Safety Category 4 Light Beam 15m 283 SLC 220/SLG 220 Type 2 Safety Light

More information

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

XUSL4E30H151N XUSL type 4 - For hand protection - Std sensing range - Hp = 1510 mm, R=30mm

XUSL4E30H151N XUSL type 4 - For hand protection - Std sensing range - Hp = 1510 mm, R=30mm Characteristics XUSL type 4 - For hand protection - Std sensing range - Hp = 1510 mm, R=30mm Complementary Detection system Response time Kit composition [EAA] effective aperture angle Emission Main Range

More information

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m) All voltage photoelectric sensors Built-in amplifier accepts wide supply voltage range. Slim, space-saving construction measures only x x 7.4 mm. s with long life expectancy and high switching capacity

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing

More information

onlinecomponents.com

onlinecomponents.com Universal Voltage Terminal Photoelectric Universal AC/DC Photoelectric Sensor with Built-in Timer Easy-to-wire terminal block Built-in timer offers selectable ON-delay, OFF-delay and one-shot Relay or

More information