Operator s Manual. masibus

Size: px
Start display at page:

Download "Operator s Manual. masibus"

Transcription

1 Operator s Manual BARGRAPH INDICATOR DUAL CHANNEL Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar , Gujarat, India. Ph: /76/77/78/79 Fax: /2 support@.com Web: OPERATION MANUAL DUAL CHANNEL 1 of 20

2 CONTENTS 1. TECHNICAL DETAILS 2. SPECIFICATIONS 3. FRONT FASCIA 4. CONNECTIONS DETAIL 5. USER GUIDE 6. MODE OF OPERATION 7. TROUBLE SHOOTING 8. MODBUS DETAIL (OPTIONAL) 9. COMMUNICATION PROTOCOL IN BARGRAPH 10. SPACIAL NOTE APPENDIX A OPERATION MANUAL DUAL CHANNEL 2 of 20

3 1. TECHNICAL DETAILS This 101 segment dual channel Bargraph indicator is versatile micro-controller based instrument designed for all industry standard inputs. For different type of I/P s only user have to select the type and range of input. It indicates the process variable on a 101- segment bar with 1-% resolution and a four digit seven segment display. The instrument is made in a 72 x 144-mm bezel size. By just unscrewing the two screws from backside the whole chassis can be opened out. Front is sealed membrane type to withstand dusty environment. Internally, the instrument is built around an 8-bit microcontroller to control the overall activity. Micro-controller is featured with ISP (In System Programming) facility so, can be directly programmed through Computer with out removing it from its place. For better noise immunity and operation at lower voltage, precision switch mode power supply is used. setting is more useful for linear inputs for setting the range between to 9999 counts. Isolated Retransmission output 4-20 ma and 0-5 VDC. Retransmission o/p is jumper selectable. Serial Communication with RS 485 is also provided for using the bargraph as backend for Supervisory Control or for P.C. connectivity. Standard protocol for communication used is MODBUS-RTU. The instrument is designed in such a fashion in order to avoid the number of hard wire connections. All PCB are self-detachable, means any card can be isolated by other card by just plugging out the connector. Apart from this there is a precaution for the costly bar display in case of failure of CPU hardware. To be more precise, if the CPU fails to refresh the data to Bar display at it's specified rate, there is an additional circuit, which will reset the bar making all segment of bar switched off. The programming, calibration and operation of the instrument is by four simple keys with two independent displays for channel 1 & 2. The product is made to accept all 7 standard thermocouple, PT100 RTD, Linear voltage and current inputs. The type of input can be changed in field also. The calibration of the unit is done without trim-pots. The unit can be calibrated in installed condition itself by front panel keys at any given point. The instrument software is written to provide all possible features with minimum hardware requirements. It is having a powerful watch dog circuit with a close monitoring of the software loop. This ensures the instrument operation in case of power spikes or mains noise. This may not protect the instrument from these but can bring the instrument out of disturbances caused to the micro-controller software due to such spikes. Provision for zero and span setting is made to restrict range of usage and programming. This restricts accidental wrong setting of set point beyond the range of interest. Outside this range the unit will indicate data as OVER towards span side up to 5% more than programmed span and UNDR towards zero side up to 5% less then programmed zero. Outside the full scale the unit will indicate data as OPEN. This zero and span OPERATION MANUAL DUAL CHANNEL 3 of 20

4 2. SPECIFICATIONS PV Input Signals: Number of Inputs: 2 Input Type: 1. Thermocouple types B, E, J, K, R, S & T (ANSI standard) 2. RTD - Pt100 3-wire ma/1-5 V DC linear mA/0-5 V DC linear Note: Other types on request Input field select ability Cold junction compensation automatic for thermocouples Accuracy: ± (0.1% of full scale + 1 Count) Resolution: 14 1/2 bits Sampling Period: 500 ms Burn out detection: Input shows OPEN in display. Burn out Current: 1.2 ua Measuring Current in RTD : 0.166mA Input Resistance: TC / V : >1 MΩ Allowable signal source resistance: 1.TC input: 100Ω or less Effect from allowable signal source.. resistance: 2.4 uv / Ω or less 2. DC input voltage: 1KΩ or less Effect from allowable signal source.... resistance: 0.01 % / 100Ω or less Allowable lead wire resistance: 15Ω / wire or less Effect from allowable lead wire..... resistance: 0.66 C / 10Ω or less Allowable Input Voltage: TC / RTD: ±10V DC DC voltage: ±20V DC Noise Rejection Ratio: Common Mode: > 100 db (50 Hz) Normal Mode: > 50 db (50 Hz) Reference-junction compensation error: ± 2 C (10 to 55 C) Applicable standard: ITS-90 Response time: 1. Input to relay o/p: < 5 Sec. 2. Input to Analog o/p: 1 second or.... less, 63%(10-90%) Range : B 450 to 1820 º C E -200 to 1000 º C J -200 to 1200 º C K -200 to 1372 º C R 0 to 1768 º C S 0 to 1768 º C T -200 to 400 º C PT to º C 4-20 ma DC to 9999 Field. Scalable 0-5 V DC to 9999 Field.. Scalable Calibration : Zero and span adjusted by front panel keyboard only. No trimpots. Operation : Four operating mode, software selectable, selected by pressing front panel keys in pre defined sequence. INC, DEC (for increase & decrease of various parameters and set points) SET & ENT (set parameters and set points) Contact Output: Usage Alarm O/P No. of relay contact outputs 4 Relay contact rating 230 VAC / 2Amp. Relay Contact terminal 3 ( NO, NC, Common) Alarm Types PV High limit, PV low limit Setting Ranges for Process Value Alarms PV Alarms Min = Zero of individual I/P type Max. = Span of individual I/P type Alarm hystersis width 0 to 100 Display Specifications: CH-1 4 digit, 0.3" Red LEDs for Process Variable 101 Segment Red Bar for indicating process variable in percentage. CH-2 4 digit, 0.3" Red LEDs for Process Variable 101 Segment Red Bar for indicating process variable in percentage. Display Update Rate : Continuous Individual Discrete Leds For Set And Relay Status Indication. OPERATION MANUAL DUAL CHANNEL 4 of 20

5 Construction, Installation, and Wiring: Case M.S. powder coated with ABS molded bezel Case color Dark Grey Protection IP54 (Front Fascia) complied (Not verified) Weight Approximately 1.7 Kg or less Bezel size 72mm(W) X 144 mm(h) X 245 mm(d) Depth behind panel 245 mm maximum including terminals Mounting Panel mounting Panel cutout 68.0mm(W) X mm(h) Chassis Fixed Standard Accessories 2 mounting clamp Terminals PCB Termination Block can accept up to 2.5 Sq.mm wire. Power Supply Specifications: Power supply 90V to 270 V AC, 50 Hz OR 24VDC + 10% Power consumption Less than 15 VA Memory backup EEPROM Primary terminal Power supply, relay output Secondary terminal Analog input/output signal terminals Withstanding voltage Between primary terminal and secondary terminal 500V AC for 1min. Between primary terminal and ground terminal 500V AC for 1min Between ground terminal and Secondary terminal 500V AC for 1min. Between two Secondary terminal 500V AC for 1min. Isolation resistance Between power supply terminal and ground terminal, 500V DC 50 MΩ Environmental Conditions: Ambient 0 to 55 deg C Humidity up to 95% RH non-condensing Warm up time > 30 min Storage Temperature 0 to 70 deg C Effect of operating conditions 1. Effect of Ambient temperature For T/C input, ± 0.01% of F.S./ C or less For Voltage input, ± 0.01% of F.S./ C or. less For RTD input, ± 0.02% of F.S./ C or less For analog output, ± 0.02% of F.S./ C or. less 2. Effect on power supply fluctuation (within rated voltage range) For analog input, within ± % of... F.S./ 10V For analog output, ± 0.01% of F.S./ 10V Isolated Retransmission Output: No of Output 2. Output Type 4-20 ma Isolated O/P. Load Impedance 600 ohms maximum. Accuracy % of Full scale. Isolation 500 VDC Output Regulation 0.01% for full load change Resolution 12 bits Isolated Transmitted Power Supply: No of Supply 1. Voltage Rating ma Isolated O/P. Isolation 500 VDC Isolated Serial Communication: Communication standard RS-485 Communication Protocol Modbus RTU. Communication method 2 wire half duplex (RS-485) Data frame N,8,1 Communication rate 9600,19200 bps Address range 001 to 247 Distance of Communication1200 meter (Twisted pair cable as per EIA 485 standard). Maximum Slaves 32 without repeaters. Isolation 500 VDC OPERATION MANUAL DUAL CHANNEL 5 of 20

6 Special function: Square root extraction 4. CONNECTION DETAIL Back panel connections are as shown in diagram given below. 3. FRONT FACIA The instrument front is a transparent Acrylic over which overlay is pasted. Left upper row of four digits represents numerical value of process variable of channel-1 and right upper row of four digits represents numerical value of process variable of channel-2. Bar is calibrated with 1-% resolution and graduated at every 5%, for ease of reading from distance. RL1 RL1 RL2 RL2 SET RL1 RL1 RL2 RL2 SET SEL OPERATION MANUAL DUAL CHANNEL 6 of 20

7 FOR CHANNEL 1: FOR CHANNEL 2: +24V TPS OUTPUT 1-24V TPS OUTPUT 2 +THERMOCOUPLE 4 INPUT -THERMOCOUPLE 5 INPUT + CURRENT INPUT 4 - CURRENT INPUT 5 * PUT 250R,0.1% RESISTOR EXTERNALY + VOLT INPUT 4 - VOLT INPUT 5 COMMON 3 IN+ 4 IN- 5 RE1+ + Re-transmission 6 output RE1- - Re-transmission 7 output D+ RS D- COMMUNICATION 9 RELAY1 COMMON-RELAY1 10 NORMALLY OPEN- RELAY1 11 NORMALLY CLOSE RELAY1 12 RE1+ RE1- RELAY1 RELAY2 +THERMOCOUPLE 20 INPUT -THERMOCOUPLE 21 INPUT + CURRENT INPUT 20 - CURRENT INPUT 21 * PUT 250R,0.1% RESISTOR EXTERNALY + VOLT INPUT 20 - VOLT INPUT 21 COMMON 19 IN+ 20 IN Re-transmission 22 output - Re-transmission 23 output COMMON-RELAY1 24 NORMALLY 25 OPEN-RELAY1 NORMALLY 26 CLOSE -RELAY1 COMMON-RELAY2 27 NORMALLY 28 OPEN-RELAY2 NORMALLY 29 CLOSE -RELAY2 RELAY2 POWER SUPPLY COMMON-RELAY2 13 NORMALLY OPEN- 14 RELAY2 NORMALLY CLOSE- 15 RELAY2 LINE/+24V 16 NEATURAL /-24V 17 EARTH USER GUIDE INTRODUCTION This is a single chip micro-controller based bargraph designed for universal input type. Instrument is operated by four user friendly keys. These keys are used for operation, programming and calibration. On applying power, the instrument will display I/P type for first five seconds. If the I/P is not connected 4 digit seven segment display will indicate OPEN and 1 to 100 LED of 101 segment bar will fully ON with 101 LED OFF for open sensor up where as for open sensor down 1 to 100 LED of 101 segment bar will fully OFF with 101 LED ON (Refer Appendix A). Now, if the I/P is connected with proper polarity, the instrument will display the process variable reading on seven segment display and bar will show process value in terms of percentage input with 1% resolution. In order to understand the operation of the instrument more precisely one whole description for Zero OPERATION MANUAL DUAL CHANNEL 7 of 20

8 value considered as 0 and span value considered as 100 is given below: In case for Linear I/P (or any Type of I/P) at 4mA(minimum value of I/P range), 4-digit seven segment should display "0" and the Bar display should indicate 0%, with 1 to 100 LED of 101 segment bar in OFF condition and 101 LED of it in "ON" condition(refer Appendix A). If the I/P value reaches to 12mA (half of the I/P range), then 4-digit seven segment display should display "50" as process variable and Bar display should indicate 50%, by turning off 101 LED of 101 segment bar and by turning on it's 50 LED's out of 1 to 100(Refer Appendix A). If the I/P reaches 20mA(maximum value of I/P range) in other terms to the span value, seven segment 4-digit display will indicate 100 as a process variable and Bar display will show 100% by turning on all 100 LED's ON with 101 LED OFF (Refer Appendix A). If the I/P ma exceeds 20mA, the process variable window will display "OPEN" message. If the I/P ma goes below 4mA, the process variable window will display "OPEN" message. For I/P TC, if the input temp. exceeds then programmed span, the process variable window will display "OVer" message up to 5% of programmed span and simultaneously the bar will flash at 100%, with 101 LED OFF, at the rate of 0.5sec. For I/P TC, if the input temp. goes below programmed zero, the process variable window will display "under" message up to 5% of programmed zero and 1 to 100 LED of 101 segment bar will OFF with 101 LED ON. This differentiates the I/P condition given to the instrument at Upper and lower limits of I/P. After 5% of programmed zero and programmed span unit will indicate OPEN and 1 to 100 LED of 101 segment bar will fully ON with 101 LED OFF for open sensor up where as for open sensor down 1 to 100 LED of 101 segment bar will fully OFF with 101 LED ON (Refer Appendix A). One additional feature to this instrument is added to protect the costly bar from the circumstances when the CPU fails to refresh the bar, by data at the specified rate according to the software. Under this condition one special watch dog hardware incorporated, will turn off the Bar and prevent it from being damaged due to long time continuous flow of current through the bar. The manual covers all aspects of operation of the instrument. Please read instructions carefully before altering any programming or configuration information. OPERATION POWER SUPPLY Always be sure that you are connecting right input supply voltage to right power terminal of the instrument. The instrument is having 3/2 terminals 230VAC/24VDC for mains Supply. On application of proper power, the instrument will display I/P type for 5 seconds and then come to RUN Mode. Now, if the input signal is connected, unit will display value of input in PV (process value) window. KEY BOARD There are four keys for operation of the instrument. For understanding the operation first let us see the operation of keys. SELECT This key is used to select the desired operating mode and parameter in various operating modes. On first press of this key, it will display Password. pass By pressing INCR/DECR Key user can change the password and using ENTER key user can give the password.if the password matches with the password set in configuration than user can view operating modes (CALb, ConF or ProG) and by pressing Enter key unit will enter into that particular operating mode. Calb Conf Prog After Entering into operating mode (CALb, ConF or ProG) first parameter will be displayed and by Pressing select key subsequent parameter will be displayed. After OPERATION MANUAL DUAL CHANNEL 8 of 20

9 the last parameter displayed, pressing of SEL key will bring the instrument in Run mode. ENTER This key is used for entering into mode (CALb, ConF or ProG) and for entering the value of the selected parameter. After setting the data to proper value, if enter key is pressed, the data will be permanently stored in nonvolatile memory. On pressing of enter key, display shows the parameter which you have entered. Now data change is not possible until INCR/DECR key pressed once again. On pressing of Enter key decimal point on last digit will glow and allow to change data. INC ( ) This key will increment the selected parameter value by one count in all operating mode. If the key is pressed continuously for more than 10 counts change, the rate of increment will be made five times faster. This facility is called dual speed increment facility to allow faster data change for higher values. This key is also used to move onto different mode (calibration, configuration and program). DEC ( ) This key will decrement the selected parameter value by one count in all operation modes.. If the key is pressed continuously for more than 10 counts change, the rate of decrement will be made five times faster. This facility is called dual speed decrement facility to allow faster data change for higher values. This key is also used to move onto different mode (calibration, configuration and program). 6. MODES OF OPERATIONS There are four modes of operations. 6.1 Run mode. 6.2 Program mode. 6.3 Configuration mode. 6.4 Calibration mode. Each are described in detail in individual chapter. 6.1 RUN MODE This is normal mode of display. From other mode of operations, display fall back to this mode if no key is pressed for 20 Seconds. In this mode PV display will show the value of input signal of each channel and bar shows the % process variable corresponding to the input. 6.2 PROGRAM MODE This mode is used for programming setpoints. In this mode setpoints data can be checked and reprogrammed. For entering this mode press Select key and then INCR/DECR to choose Program mode and then press Enter key. It will display first setpoint parameter. By pressing INCR/DECR keys value of the setpoints and hystersis can be changed as desired. If either of the key is kept pressed continuously for more than 10 counts change in setting, it will start incrementing or decrementing the data at a five time faster rate. Bring the setpoint at a desired value and press enter key for storing the value permanently. On pressing of enter key the display shows the parameter prompt. On pressing of set key other parameter in sequence are selected and changed by the same procedure. The parameters in sequence are: Sp1 Hys1 Sp2 Hys2 Sp3 Hys3 Sp4 Hys4 Setpoint1 of CH-1 Hystersis for first setpoint Setpoint2 of CH-1 Hystersis for second setpoint Setpoint1 of CH-2 Hystersis for first setpoint Setpoint2 of CH-2 Hystersis for second setpoint After the last parameter display will go back to normal run mode. If no key is pressed for 20 seconds, the display will fall back to normal run mode. 6.3 CONFIGURATION MODE This mode is useful for changing the basic configuration of the unit. No hardware changes are necessary for changing input type. It can be changed by just using front keys. OPERATION MANUAL DUAL CHANNEL 9 of 20

10 For entering this mode press select key, MODE will be displayed, now press INCR ( ) and DECR ( ) for selecting Configuration mode Conf. Now if Enter key is pressed the unit will enter in the configuration mode and will display input Inpt as first in the PV display of CH-1. Now by pressing the INCR/DECR key display will show the input type (eg. k-tc, E-tC or 4-20 ) of that channel, which can be selected by pressing Enter key. User can select the parameter to be programmed by SEL key. The parameters for both channels that can be changed by this mode are described below in sequence in which they are displayed except serial no and baud rate, which is common for both channel and will be displayed as last two parameter in channel-2 PV display. First we will see the parameter displayed. These parameters are for Channel-1 and will be displayed in Channel-1 PV display Window. Inpt zero SpaN Tsp1 Tsp2 Sqrt dp --- Input type. --- Zero setting. --- Span setting. --- Type of first set-point. --- Type of second set-point. ---Square root enable/disable. --- Decimal point position. These parameters are for Channel-2and will be displayed in Channel-2 PV display Window. Inpt zero SpaN Tsp1 Tsp2 Sqrt dp --- Input type. --- Zero setting. --- Span setting. --- Type of first set-point. --- Type of second set-point. --- Square root enable/disable. --- Decimal point position. These parameters are common for Channel-1 & 2 and will be displayed in Channel-2 PV display Window. srno baud pass --- Serial No. --- Baud Rate --- Pass word INPUT TYPE Type of input is displayed as code for input type. The type of inputs available is E, J, K, T, B, R, S, SPL, RTD, 4-20 ma DC and 0-5 Volt DC with display prompt shown below. Input type can be selected by INC key or DEC key. Input type and each type of input is displayed by prompt as follows. Inpt E-tc J-tc K-tc T-tc B-tc R-tc S-tc Spl E - type thermocouple -200 to 1000 J - type thermocouple -200 to 1200 K - type thermocouple -200 to 1372 T - type thermocouple -200 to 400 B - type thermocouple 450 to 1820 R - type thermocouple 0 to 1768 S - type thermocouple 0 to 1768 Special - type for any new input type 0 to 1768 Rtd RTD PT-100, 0.1 deg. Resolution to ma or 1-5 V input to V input or 0-20 ma to 9990 For changing of input type, no internal hardware changes are required. If input type is 4-20mA then you are required to connect the 250ohm Resistors supplied between the INHI and INLOW terminals of the terminal plate. When an input type is selected its corresponding zero and span range is automatically adjusted as per its table. However if user wants to change zero and span as required he can move to the zero or span prompt and can change. With this facility if the same input is selected (ie. ENTER key is pressed on the same input), its zero and span range is kept as it is. For setting the range as per the table one has to OPERATION MANUAL DUAL CHANNEL 10 of 20

11 change the input first and then change back to same input as required. Refer corresponding range as per the inputs. ZERO & SPAN These settings are for specifying minimum and maximum range of operation. Zero and Span for both Channels is displayed by Prompt as follows. zero span This allows to select any value between Range of particular Input. This value can be changed any time to make instrument enable to use for any type output transmitter or such other instrument. The setpoint can not be set below the zero setting and above the span setting. The reading will display undr when input is below zero setting by 5% and will display over when input is above span setting buy 5%. This 5% is calculated for the difference of zero and span settings. Outside the full scale the unit will indicate data as OPEN. TYPE OF SET-POINT There is two set point for each Channel and it can be defined as Low-ON or High-ON. Low and High ON means that Relay will operate when PV is higher or lower then Set-Point. The Set-Point parameter for both Channels is displayed by Prompt as follows. tsp1 tsp2 Type of Set Point can be selected by INC key or DEC key and is displayed by prompt, for both Channel as follows. l-on - ON If PV (Process Variable). is lesser then Set-Point. H-ON - ON If PV (Process Variable). is Higher then Set-Point. SQUARE ROOT By making this prompt yes user can use 4-20 ma as square root input type. The 4-20 ma input type will be very much useful in flow measurement application. For example if input type is 4-20 ma with square root yes and zero and span scaling is 0 to 1000 with dp at position one, then at different input process variable will be as under ma input Square root calculated inside Process Variable ( 0%) (25%) (50%) (75%) (100%) This parameter can be displayed by prompt shown below. Sqrt Above example is just for explanation purpose only, user can set any value at zero and span parameter. Basic equation to calculate process variable for 4-20mA square root input type is Square root ( (input - 4mA )/16) * 100 %. DECIMAL POINT This parameter can be displayed by prompt shown below. dp This decides the decimal point position. Decimal point position can be programmed from 0 to 3. Position of zero means no decimal point. Any non zero number puts decimal point after that digit. For example if decimal point position is set to two and reading is 1000, it will be displayed as Make sure to put correct decimal point. SERIAL NUMBER This parameter is basically used for modbus communication, to identify the unit. modbus communication is master and slave communication, in which master will send query and slave will give response. If there are multiple slave connected, so to synchronies communication, slave has its identification no (serial no) and it responds to only those query, which have its serial no. Range of serial no is from 001 to 247. OPERATION MANUAL DUAL CHANNEL 11 of 20

12 Srno 001 to 247 This parameter is required while using the Serial Communication facility. It represents the serial number or the ID number of the Unit. It can be configured between 001 and 247 by using INC/DEC keys. BAUD RATE bd k This parameter is used to set the BAUD RATE for serial communication. Different baud rates can be selected by using INC/DEC keys. In Asynchronous communication, master and slave has its separate clock source, for synchronizing, they must have same baud rate. Baud rate can be set from 9600 and 19.2KB. PASS WORD pass Pass word for entering in program mode,configureation mode and calibration mode. Factory set password is 10. CALIBRATION MODE The instrument is factory calibrated for the specified range, but due to long term drift of components, recalibration may be necessary in some cases. For calibrating the instrument a reliable source is required. This source should be at least ten times accurate compared to the range of the instrument. You can calibrate instrument after entering in Calibration mode. Here there are 4 groups of calibration. Group 1: E-t/c, Jt/c, Kt/c, Tt/c. Group2 : Bt/c, Rt/c, St/c. Group3 : RTD, Group4 : 0-5V, 4-20mA. The unit can be calibrated with opening it and without trimpots. For entering this mode press Select key and then INCR/DECR to choose Calibration mode and then press Enter key. It will display first set point parameter. Now the calibration parameter is selected by pressing the select key. The parameters in sequence are as below: Calz Cals rtrz - Zero Calibration prompt for CH-1 -Span Calibration prompt for CH-1 - Retransmission zero Calibration prompt for CH-1 rtrs -Retransmission span Calibration prompt for CH-1 Cala -Ambient Calibration. Calz -Zero Calibration prompt for CH-2 Cals rtrz -Span Calibration prompt for CH-2 - Retransmission O/P zero Calibration prompt for CH-2 rtrs -Retransmission O/P span Calibration prompt for CH-2 Calibration procedure for CH-1 is described below and CH-2 calibration procedure is same as CH-1. [1] Calibration procedure for ANALOG INPUT. [A] For T/C type 1. Short the input terminals. 2. Press the SET Key and then press INC/DEC Key to select CALb (Calibration mode) and press ENTER key. Now press SET key four times, SV window will indicate CALA. Now set the current ambient temperature with the help of INC or DEC keys and press ENTER key to calibrate Ambient. 3. Feed the mv (Amb. subtracted except for B type) according to the T/C chart (For TC type) for ZERO value. 4. Again go to Calibration mode by Pressing the SET Key and then press INC/DEC Key to select CALb (Calibration mode) and press ENTER key. SV window will indicate CALZ. Now set the ZERO (lower limit of range) with the help of INC or DEC keys and press ENTER key to calibrate ZERO value. 5. Feed the mv (Amb. subtracted except for B type) according to the T/C chart (For TC type) for SPAN value. 6. Press the SET Key once. More, SV window will indicate CALS. Now set the SPAN (higher limit of range) by INC or DEC keys and press ENTER key to calibrate OPERATION MANUAL DUAL CHANNEL 12 of 20

13 SPAN (value is according to requirement & TC type). Now check the linearity for the whole range. [B] For RTD type 1. Set the input resistance at ohm, get CALZ on the display and set it to 00.0 C by INC or DEC keys and press ENTER key to calibrate ZERO. 2. Now set the input resistance at ohm. Get CALS on the display and set by INC or DEC keys and press ENTER key to calibrate SPAN. Now check the linearity for the whole range. [C] For Linear type 1. Set the input at ma, get CALZ on the display and set it to by INC or DEC keys and press ENTER key to calibrate ZERO. 2. Now set the input at ma. Get CALS on the display and set 9990 by INC or DEC keys and press ENTER key to calibrate SPAN. Now check the linearity for the whole range. [2] Calibration procedure. for ANALOG OUTPUT. 1. Enter into calibration mode as explained in the above paragraph. 2. Now PV window will display rtrz and Press INC/DEC Key it will display (4 ma). With help of INC or DEC keys set the ma value exactly same as at Amperemeter reading connected at output. Now Press ENTER key to calibrate O/P for 4 ma. 3. Now on pressing SET key PV window will display rtrs (calibrate span) and by pressing INC/DEC Key window will display and 2.. (20 ma). With help of INC or DEC keys set the ma value exactly same as on Ampere-meter reading connected at output. Press ENT key to calibrate O/P for 20 ma. Now check the linearity for the whole range. (Refer Appendix A) 7. Trouble shooting Bargraph does not Switch ON. Check the Mains Cord. I/P power may not be present. Check power supply voltage is it proper as per order. Check fuse, if blown off replace it in SMPS. Check the Power ON Indication LED in SMPS. Calibration of the unit is doubted to have drifted. Check the O/P of sensor is as per the chart supplied to you by sensor manufacturer. Measure it with instrument with better then 0.1% accuracy. Standard multi-meter with 3½ digit display may have poor accuracy then bargraph. For temperature measurements check position of the sensor and check for the problem related to sensor first. Calibrate the unit as explained in the manual. Select the proper method according to your bargraph input type. In linear type input the unit shows false reading or OVER or UNDER. Check for the polarity of the I/P connections. Check that the 250Ω resistor is connected across the I/P terminals, if the I/P type is 4 20 ma. 250Ω resistor is mandatory for linear I/P type 4 to 20mA. Check the current I/P coming from the field, it may be below 4 or over 20 ma. Check for the proper range programmed in that channel. In thermocouple type input the reading indicated has got some error. OPERATION MANUAL DUAL CHANNEL 13 of 20

14 Check for the proper I/p type selected. Ensure that the compensating cables used are of proper type and connected in proper direction Positive and negative. Check the calibration of the unit. Check that proper zero-span range is programmed or not. Reading indicated by Bargraph is unstable, wrong or open. Check the process input and also check their connections are as per the back-plate supplied. Ensure the perfect EARTHING to the unit & also check that neutral should not be floating. Shielded cables should used for input. Shield should be EARTHED near the unit only. Check any of the sensor is not getting EARTHED or having weak insulation with respect to earth. If so, remove that sensor and check the cabling. Check the lead resistance of all the three arms of RTD s. All the three leads should have same lead resistance. If no, change the cables. Check that Input cables are properly tighten Take separate earth wires for separate instruments, avoid looping of earth wires. Check for AC voltage pick up at the signal at Bargraph side All low-level input and output such as T/C, RTD, Linear I/P and control signal wires must be kept separate from supply and relay output cabling. Communication Problem between the Unit and Host PC/Operator Terminal Check the cabling. Check the serial No. and baud rate settings at PC side and Bargraph side. Check the RS-485 to RS232 converter for 485 communications. Check RS 232 RS 485 connection at PC and Bargraph side. Relay O/P Action problem Check power to the contactor operated by relay from Bargraph. If relay burnt out frequently check for the rating of the relay or rating of contactor driven by relay. General In Configuration, Program, Verify Configuration, Verify Program and Calibration modes, 20 Sec time out is provided i.e. if no key is pressed for 20 second, it will fall back into Run/Man mode. While programming value, if the INC or DEC key is kept pressed for more than 10 counts, the Speed of change will be increased by 5 times. It is the dual speed concept for changing value at faster rate. On power on Bargraph will first display input type, and then it will come to actual Run mode display. If there is any error in EEPROM data, it will display error message and halt. -Err SUPPLY VOLTAGE Supply voltage should be given through a good isolation transformer. This being a microprocessor based instrument, a massive voltage spike can damage it. A good isolation transformer shields the instrument from such voltage spikes and surges. All supply connections to final control devices such as contactors, solenoids etc. must be taken directly from the supply and not from the supply terminals of the instrument. An effective earth is mandatory for the instrument. In absence of proper earthing instrument body will float at half some part of the supply voltage and this may give shock to user. This is an electronics instrument it may have problem not listed above, in case of such fault while reporting to factory (Masibus area office or head office), mention exact nature of fault with sequence of events. OPERATION MANUAL DUAL CHANNEL 14 of 20

15 8. MODBUS DETAIL (OPTIONAL) MESSAGE QUERY: INTRODUCTION The bargraph can be connected in RS-485 communication data link either in multi drop or repeat mode. Each bargraph must have unique Serial Number. No two bargraph have the same address. Entire range of addresses (001 to 247) may be used. Before starting any communication, choose a baud rate and protocol compatible to the host computer. Only two-pass protocol is available on bargraph and hence when using the bargraph, only two-pass protocol is assumed. This speeds up the total throughput. COMMUNICATION PROTOCOL The communication protocol is a Modbus protocol. The host computer issues the commands to the bargraph that in turn respond to each command. The entire protocol is based on the command/answer protocol. How Characters are transmitted serially When messages are transmitted on standard Modbus serial networks, each character or byte is sent in this order (left to right): Least Significant Bit (LSB)... Most Significant Bit (MSB) With RTU character framing, the bit sequence is: RTU Framing i.e. 1 start bit, 2 stop bit and No parity. START DELAY and ADDRESS: Always contains the start of message with 3.5 null char delay followed by the address of the bargraph to be addressed. The address is represented by a HEX character ranges from 001 to 247. OPERATION MANUAL DUAL CHANNEL 15 of 20

16 FUNCTION: When a message is sent from a master to a slave device the function code field tells the slave what kind of action to perform. In bargraph the functions implemented are 01 READ COIL STATUS (REFERENCE - 0x). 03 READ HOLDING REGISTERS.. (REFERENCE- 4x). 06 PRESET SINGLE REGISTER... (REFERENCE - 4x). Here Same Reference Functions are used for Reading and Writing a parameter, so only one Variable Tag is required for reading and writing a parameter. DATA FIELD: Read: The query message specifies the starting register and quantity of registers to be read. Registers are addressed starting at zero- registers are addressed as Write: The query message specifies the register address and the data to be written in that register. Registers are addressed starting at zero- register 1 is addressed as 0. message to the current contents of the register. Only the eight bits of data in each character are used for generating the CRC. Start and stop bits, and the parity bit, do not apply to the CRC. During generation of the CRC, each eight-bit character is exclusive ORed with the register contents. Then the result is shifted in the direction of the least significant bit (LSB), with a zero filled into the most significant bit (MSB) position. The LSB is extracted and examined. If the LSB was a 1, the register is then exclusive ORed with a preset, fixed value. If the LSB was a 0, no exclusive OR takes place. This process is repeated until eight shifts have been performed. After the last (eighth) shift, the next eight-bit byte is exclusive ORed with the register's current value, and the process repeats for eight more shifts as described above. The final content of the register, after all the bytes of the message have been applied, is the CRC value. When the CRC is appended to the message, the low-order byte is appended first, followed by the high-order byte. MESSAGE RESPONSE : CHECKSUM COMPUTATION: The error checking field contains a 16-bit value implemented as two eight-bit bytes. The error check value is the result of a Cyclical Redundancy Check (CRC) calculation performed on the message contents. CRC calculation: The CRC field checks the contents of the entire message. It is applied regardless of any parity check method used for the individual characters of the message. The CRC value is calculated by the transmitting device, which appends the CRC to the message. The receiving device recalculates a CRC during receipt of the message, and compares the calculated value to the actual value it received in the CRC field. If the two values are not equal, an error results. The CRC is started by first pre loading a 16- bit register to all 1's. Then a process begins of applying successive eight-bit bytes of the OPERATION MANUAL DUAL CHANNEL 16 of 20

17 9. COMMUNICATION PROTOCOL IN BARGRAPH 1.START DELAY AND ADDRESS: When the bargraph Indicator sends its response, it places its own address in this address field of the response to let the master know which bargraph Indicator is responding. 2.FUNCTION: When the bargraph Indicator responds to the master, it uses the function code field to indicate either a normal (error-free) response or that some kind of error occurred (called an exception response). For a normal response, the bargraph Indicator simply echoes the original function code. For an exception response, the bargraph Indicator returns a code that is equivalent to the original function code with its most significant bit set to logic 1. 3.DATA FIELD: If no error occurs, the data field of a response from a bargraph Indicator to a master contains the data requested. The char will be the byte count of data requested. For the write command the response will be an echo of the query. If an error occurs, the field contains an exception code that the master application can use to determine the next action to be taken. 4.CHECKSUM COMPUTATION: CRC of the message is calculated same way as explained earlier and appended to message. EXCEPTION RESPONCE : The table explains the meaning of error codes, if bargraph Indicator transmits error message. CODE MEANING 01 Function code Invalid. It must be 01,03 or Illegal data starting address. The range is specified for different functions in the table below. 03 Illegal data value. The range is specified for different functions in the table below. 08 Check sum ( CRC ) error. Garbled message. The table show Digital data to be transmitted and its sequence. Sr. No. Digital Parameters Type of Access Parameter Type Absolute Address 1. RELAY -1 Read Bit RELAY 2 Read Bit RELAY 3 Read Bit RELAY 4 Read Bit The table show Analog data to be transmitted and its sequence. OPERATION MANUAL DUAL CHANNEL 17 of 20

18 Sr. No. Analog Parameters Type of Access Parameter Type Absolute Address 1. PROCESS VALUE-1 Read Int PROCESS VALUE-2 Read Int SET POINT-1 Read/write Int SET POINT-2 Read/write Int SET POINT-3 Read/write Int SET POINT-4 Read/write Int SET POINT-1 HYSTERESIS Read/write Int SET POINT-2 HYSTERESIS Read/write Int SET POINT-3 HYSTERESIS Read/write Int SET POINT-4 HYSTERESIS Read/write Int INPUT-1 Read/write Int ACT _ZERO-1 Read/write Int ACT_SPAN-1 Read/write Int TYPE OF SETPOINT-1 Read/write Int TYPE OF SETPOINT-2 Read/write Int SQUARE ROOT-1 Read/write Int DECIMAL POINT-1 Read/write Int OPEN SENSOR-1 Read/write Int INPUT-2 Read/write Int ACT _ZERO-2 Read/write Int ACT_SPAN-2 Read/write Int TYPE OF SETPOINT-3 Read/write Int TYPE OF SETPOINT-4 Read/write Int SQUARE ROOT-2 Read/write Int DECIMAL POINT-2 Read/write Int OPEN SENSOR-2 Read/write Int BAUD RATE Read/write Int SERIAL NO. Read/write Int AMBIENT Read Int PASSWORD Read Int Note : a) Display on BARGRAPH will show over when process value is higher then 5 % of individual span, at that time BARGRAPH will send to PC. b) Same way when process value is lower then 5 % of individual zero BARGRAPH will show under on its display but it will send to PC. c) If BARGRAPH process value is out of limit for particular I/P type then BARGRAPH will show Open on display but it will send to PC d) The serial no of bargraph Indicators must be within 001 to 247. e) Before starting the communication, match the Baud rate and Sr. no. of Master and Slave devices. OPERATION MANUAL DUAL CHANNEL 18 of 20

19 10. SPECIAL NOTE This controller is storing all data programmed at factory. There are lot of software and hardware protections added for safeguarding against data corruptions. There can be a very rare possibility of data getting disturbed. The controller is having unique algorithm to store data at multiple places. So, even if the data in one place gets disturbed, it is automatically overridden by other correct data values. It is also having software protections against accidental writing to EEPROM also. Even after all this, if the data gets corrupted by heavy transients on power line or noise on power line ( for which protections are already given in hardware ), the unit will display ' Err' message on the display. If such symptoms are seen the system should be needed to be reprogrammed. APPENDIX A Table for BAR: OPEN SENSOR BAR PV ON DISPLAY UP DOWN UNDER -5% 0% 1% 100% 5% OVER OPEN 1 to 100 OFF OFF OFF ON ON ON FLASH FLASH 101 ON ON ON OFF OFF OFF OFF OFF 1 to 100 OFF OFF OFF ON ON ON FLASH OFF 101 ON ON ON OFF OFF OFF OFF ON Table for Retransmission O/P: Input: RTD Range : -200 deg C to 850 deg C Retransmission o/p: 4 to 20mA. Retransmission o/p will follow as the below indication: Set zero= 0, Set span = 500 Process value on display Open sensor UNDER -25 (5%) 0 0<PV< (5%) OVER OPEN ma O/P Retrasmission UP 3.2 ma 3.2 ma DOWN 3.2 ma 3.2 ma 4 ma 4 ma 4mA<O/P <20mA 4mA<O/P <20mA 20 ma 20 ma 20.8 ma 20.8 ma 20.8 ma 20.8 ma 20.8 ma 3.2m A Note: 1. For above table default I/P type is RTD. 2. For TC I/P above table is also applicable. OPERATION MANUAL DUAL CHANNEL 19 of 20

20 Below Table shown display values only according to PV for Linear Input Type. For Retransmission output please follow above table Table for Retransmission O/P according to below display values. Input: Linear Range: 0 to 500 OPEN (I/P Type of SQRT BELOW TOTAL -25 PV >0, input RANGE) UNDER (5%) 0 PV < mA NO UNDER UNDER mA YES UNDER UNDER UNDER mA NO mA YES (5%) OVER OPEN(I/P OVER TOTAL RANGE) PV >0, PV < OVER OPEN PV >0, PV < OPEN OPEN OPEN PV >0, PV < OVER OPEN PV >0, PV < OPEN OPEN OPEN Table for Relay Logic: CONDITION NORMAL ABNORMAL UP (O/S) DOWN(O/S) HH HL Relay 1 OFF ON ON OFF Relay 2 OFF ON ON OFF Relay 1 OFF ON ON OFF Relay 2 OFF ON OFF ON LL Relay 1 OFF ON OFF ON Relay 2 OFF ON OFF ON Note: 1. This Table is made with assumption of being normal relay status of relay is off and abnormal relay status will be relay on. 2. Hysteresis is assumed to be Zero. OPERATION MANUAL DUAL CHANNEL 20 of 20

masibus DIGITAL CONTROLLER 5002U Ref No: m55a/om/101 Issue No: 08 Operator s Manual Operator s Manual Page 1 of 20

masibus DIGITAL CONTROLLER 5002U Ref No: m55a/om/101 Issue No: 08 Operator s Manual Operator s Manual Page 1 of 20 Operator s Manual DIGITAL CONTROLLER 5002U Operator s Manual Page 1 of 20 CONTENTS 1. TECHNICAL DETAILS 2. SPECIFICATIONS 3. DIMENSIONS & PANEL CUTOUT 4. FRONT FASCIA 5. CONNECTIONS DETAIL 6. USER GUIDE

More information

Masibus Automation And Instrumentation Pvt. Ltd.

Masibus Automation And Instrumentation Pvt. Ltd. Operator s Manual DIGITAL CONTROLLER 5006H Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Ph: 91 79 23287275-79 Fax: 91 79

More information

OPERATIONAL MANUAL FOR 85XX

OPERATIONAL MANUAL FOR 85XX TECHNICAL DETAILS OPERATIONAL MANUAL FOR 85XX Ref. No. : m83/om/402 This is a versatile microcontroller based Scanner with a very high performance to price ratio. The features offered in this product are

More information

masibus : UT-94 Page 1 of 6 INTRODUCTION SPECIFICATIONS Dimensions Document Ref No. m98a/om/101 Issue No: 08

masibus : UT-94 Page 1 of 6 INTRODUCTION SPECIFICATIONS Dimensions Document Ref No. m98a/om/101 Issue No: 08 INTRODUCTION This is a micro-controller based Universal Transmitter which retransmits the Universal Inputs given, into the required Voltage or current. This instrument provides isolation at 4 levels: (a)

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

OPERATOR S MANUAL 9000U ISOLATOR

OPERATOR S MANUAL 9000U ISOLATOR OPERATOR S MANUAL 9000U ISOLATOR Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Ph: 91 79 23287275-79 Fax: 91 79 23287281,

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4

9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4 Doc.Ref.No.:m92E/om/101 INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4 ISOLATED CONVERTER 9000C SERIES 9000C Series

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56" (14.2 mm) or 1.20" (30.5 mm) Linear or Square Root with Low-Flow Cutoff

More information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points) Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE

More information

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000 FEATURES Complete sensor to RS-232/RS-485 interface. 500V rms analog input isolation. 15 bit measurement resolution. Continuous self-calibration;

More information

SINGLE-CHANNEL PROCESS INDICATOR series 8001

SINGLE-CHANNEL PROCESS INDICATOR series 8001 SINGLE-CHANNEL PROCESS INDICATOR series 8001 Analog Inputs - all inputs available in one unit - Pt100 RTD type DIN 43 760 or GOST 6651-78 (range from 0 to +600 C) - TC type: J - range from 0 to +600 C

More information

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE

More information

SX90 Process Controller

SX90 Process Controller Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Tempco Instruction Manual

Tempco Instruction Manual Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed

More information

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES 11/17 D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES D7000 FEATURES Complete data acquisition systems. Analog and Digital I/O models available. RJ-45 Ethernet 10/100MB interface. Modbus TCP/IP Ethernet

More information

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL v 1.0 Thanks for choosing the Intelligent temperature and humidity controller

More information

/8 DIN Universal Process Indicator

/8 DIN Universal Process Indicator Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission

More information

DIGITAL PROCESS CONTROLLER

DIGITAL PROCESS CONTROLLER 1 DPC 965 M R1 R2 R3 R4 TX RX PROG [OPERATOR S MANUAL] 2 Contents Section 1 specification.page 4 Section 2 system Programming Page 4 to 11 Section 3 Precautions..Page 11 Section 4 Connection Diagram.Page

More information

RTD Temperature acquisition converter WJ25

RTD Temperature acquisition converter WJ25 8-CH Thermocouple Signal to RS485/232 Acquisition Converter (WJ27 series 24Bits A/D Converter, data acquisition) Features: >> Eight channels thermocouple signal acquisition, isolated converter RS-485/232

More information

LD-RTD / LD-TC Temperature Controller

LD-RTD / LD-TC Temperature Controller 1 LD-RTD / LD-TC Temperature Controller Available in either an RTD model or a thermocouple model, these units accept all common temperature probe types, and offer a technically advanced, but cost effective

More information

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160 Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2 Level Indicator L150 and L160 Electrical Safety This equipment complies with the requirements of CEI/IEC 61010-1:2001-2 "Safety requirements

More information

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector. PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION

More information

CHAPTER 1. Introduction Introduction 3

CHAPTER 1. Introduction Introduction 3 Technical & User Manual Weight Indicator: SMIT-3015 Manufactured By: Samyak Instrumentation Pvt.Ltd. F-4, Memnagar Complex, Opp.Petrol Pump, Memnagar Village, Ahmedabad, India-380052. Phone: +91-79-27495500/5600,

More information

High Voltage DC Meter

High Voltage DC Meter High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES Digital Panel Indicators A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input Analogue Output

More information

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement Acquisition Measurement Control The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input

More information

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

DKM-407 DIN RAIL TYPE NETWORK ANALYZER DKM-407 User Manual DKM-407 DIN RAIL TYPE NETWORK ANALYZER DESCRIPTION The DKM-407 is a DIN rail mounted precision and low cost unit allowing measurement and remote monitoring of AC parameters of a distribution

More information

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog

More information

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review... TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...

More information

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2. Section 1.0 Introduction 1.1 Important user information... 2 1.2 General... 2 1.3 Manual description...2 Contents Section 2.0 Specification 2.1 General technical data...3 2.2 Dimensions...3 Section 3.0

More information

dual-line 6-dIGIt process MeteR

dual-line 6-dIGIt process MeteR dual-line 6-dIGIt process MeteR ProVu Se r i e S provu Model pd6000 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs NEMA 4X, IP65 Front Universal 85-265 VAC or 12/24 VDC Input Power Large Dual-Line 6-Digit

More information

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator

More information

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Two cards providing 8 channels of temperature and process monitoring for VM 600 systems 8 channels of software selectable

More information

Wall-/Pipe Mounted Universal Process Indicator

Wall-/Pipe Mounted Universal Process Indicator Data Sheet SS/_8 Wall-/Pipe Mounted Universal Process Indicator High visibility LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

OPERATING MANUAL FOR SMIT-301MH STREAM SELECTOR

OPERATING MANUAL FOR SMIT-301MH STREAM SELECTOR OPERATING MANUAL FOR SMIT-301MH STREAM SELECTOR Manufactured By: INSTRUMENTATION PVT. LTD. F-4 Memnagar complex, Opp. Petrol Pump Memnagar, Ahmedabad, India-380 052 Phone: +91-79_ 2749 5500/5600 FAX: +91-79-2741

More information

Temperature Measurement

Temperature Measurement Copyright 1999-2002. All rights reserved. Web design by Sullivan Creative -1000 to +3500 and -10000 to +35000 Count Thermocouple, RTD, and Thermistor Temperature Measurement in C or F without Recalibration

More information

HIGH-VOLTAGE DC METER

HIGH-VOLTAGE DC METER HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

IFC 100 Supplementary instructions

IFC 100 Supplementary instructions IFC 100 Supplementary instructions Signal converter for electromagnetic flowmeters Description of Modbus interface Electronic Revision: ER 3.0.xx Modbus version: 1.0.xx KROHNE CONTENTS IFC 100 1 Important

More information

C160 Wall-/Pipe Mounted Universal Process Indicator

C160 Wall-/Pipe Mounted Universal Process Indicator Data sheet DS/ EN Rev. I Wall-/Pipe Mounted Universal Process Indicator reliable process indicator, wherever it s needed High visibility LED display the clearest view of your process status 0.1% measurement

More information

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM FEATURES Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal

More information

MODCELL 2050R Single Loop Controllers

MODCELL 2050R Single Loop Controllers Isolated universal process and remote set-point input Four internal set-points No jumpers required to define instrument parameters Ratio/bias on process and remote set-point Totalizer Ramp/soak profile

More information

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Voltage Input 3B30 / 3B31 FEATURES Interfaces, amplifies, & filtersanalog input voltages. Narrow-bandwidth (3Hz) single-channel single conditioning. Module provides simultaneous precision voltage

More information

Instruction Manual. Instrument Amplifier HE 017

Instruction Manual. Instrument Amplifier HE 017 Instruction Manual Instrument Amplifier HE 017 List of contents INSTRUCTION MANUAL: HE 017 Date: 20.4.99 Art.-No.: 320999 S General Safety Instructions.......................................... S 1 General

More information

ProfiPro Distributed PROFIBUS I/O Modules User Manual

ProfiPro Distributed PROFIBUS I/O Modules User Manual ProfiPro Distributed PROFIBUS I/O Modules User Manual 15/03/2012 V1.0 22/195 Prospect Highway Seven Hills 2147 NSW Australia Tel: +61 (02) 96248376 Fax: +61 (02) 96208709 Email: proconel@proconel.com Web:

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

TRANSDUCER T4311, T4411

TRANSDUCER T4311, T4411 TRANSDUCER T4311, T4411 Programmable temperature transducer for RTD Pt1000 sensor with serial output RS232 and RS485 Instruction manual Instruction Manual for use of transducer: T4311 (RS232), T4411 (RS485)

More information

Signal Isolators & Conditioners

Signal Isolators & Conditioners WJ21 series Analog Signal to RS485/232 Converter (A/D Converter) Features: >> Analog signal acquisition, isolated RS-485/232 output >> 12-bit AD converter, testing accuracy>0.1% >> Can Program and calibrate

More information

JSD81 series products are based on SCM's intelligent monitoring and control system, users set the calibration value,

JSD81 series products are based on SCM's intelligent monitoring and control system, users set the calibration value, 8-Channel Analog Signals to RS485/232 Converter(A/D Converter JSD81 series) Features: 8-CH analog signal acquisition/isolation,rs-485/232 output 24-bit AD converter, testing accuracy>0.05% Can Program

More information

NOW A PRODUCT! 1/4 DIN Auto/Manual Station. The Interface Solution Experts. The Interface Solution Experts. PS532 V6 March 2017

NOW A PRODUCT! 1/4 DIN Auto/Manual Station. The Interface Solution Experts. The Interface Solution Experts. PS532 V6 March 2017 NOW A 5 3 2 The Interface Solution Experts PRODUCT! 5 3 2 1/4 DIN Auto/Manual Station The Interface Solution Experts PS532 V6 March 2017 GENERAL DESCRIPTION The 532 Auto/Manual Station ensures the integrity

More information

User s manual. Programmable panel meter IPD

User s manual. Programmable panel meter IPD User s manual Programmable panel meter IPD Assembly Wall assembly: +0,5 +0,2 Window of 46 x 91 mm (2.5" x 3.5" ) Made with ABS (UL94-HB) -0-0 General cares in the installation The equipments must not be

More information

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES Interfaces, amplifies, protects& filters wide-bandwidth (h0 khz) single-channel analog voltage inputs. Module provides simultaneous precision voltage

More information

Measurement Systems Datascan Installation and User Guide

Measurement Systems Datascan Installation and User Guide Measurement Systems Datascan Installation and User Guide Supplied By Contents Contents 1. INTRODUCTION... 1 1.1 GENERAL... 1 1.2 DATASCAN MODULE RANGE... 1 1.2.1 Measurement Processors... 1 1.2.2 Analog

More information

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT

More information

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter. H3 Series Dual-Line 6-Digit Temperature Meter Temperature J, K, T, E, R, S, B, N, C Thermocouples 100 or 1000 Ω Platinum, 10 Ω Copper, 120 Ω Nickel RTDs 1 or 0.1 Resolution Averages up to 10 RTD Sensors

More information

DUAL-LINE TEMPERATURE METER

DUAL-LINE TEMPERATURE METER DUAL-LINE TEMPERATURE METER PROPLUS YPP7000 J, K, T, E, R, S, B, N, C Thermocouples 100 or 1000 Ω Platinum, 10 Ω Copper, 120 Ω Nickel RTDs 1 or 0.1 Resolution Averages up to 10 RTD Sensors Automatic Cold

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0. LAUREL ELECTRONICS, INC. Laureate Thermocouple Panel Meter / Controller Features Factory calibrated for thermocouple types J, K, T, E, N, R, S Entire range of each thermocouple in one scale Highly accurate

More information

Process & Temperature Digital Panel Meter

Process & Temperature Digital Panel Meter Process & Temperature Digital Panel Meter TRIDENT PD765 4-20 ma, ± 10 V, TC & RTD Inputs NEMA 4X, IP65 Front Shallow Depth Case 3.6" Behind Panel Universal Power Supply 85-265 VAC Two Relays Option with

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various

More information

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,

More information

/8 DIN Motorized Valve Controller

/8 DIN Motorized Valve Controller Data Sheet SS/_5 Boundless motorized valve controller no need for slidewire feedback; improves reliability Two sealed 5A control relays suitable for direct connection to the valve, reducing installation

More information

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250 User Guide IM/C250 MOD_3 Modbus (RTU) Communications Option C250 and V250 Electrical Safety This instrument complies with the requirements of CEI/IEC 61010-1:2001-2 "Safety requirements for electrical

More information

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities COMMANDER Universal Process Controller Specification DataFile PID controller with one shot autotune single loop, heat/cool and ramp/soak as standard Quick code, front face or PC configuration easy commissioning

More information

1.Eastron SDM230Modbus Smart Meter Modbus Protocol Implementation V1.2

1.Eastron SDM230Modbus Smart Meter Modbus Protocol Implementation V1.2 1.Eastron SDM230Modbus Smart Meter Modbus Protocol Implementation V1.2 1.1 Modbus Protocol Overview This section provides basic information for interfacing the Eastron Smart meter to a Modbus Protocol

More information

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series The Digitec Series D3800 Panel Meters offer many features and performance capabilities to suit a wide range of industrial applications. The D3820 and D3830 are available in the ranges of 4-20mA, 0-10 VDC,

More information

T2314, T2414. Instruction Manual

T2314, T2414. Instruction Manual Atmospheric pressure transmitter T2314, T2414 with RS232 / RS485 serial output Instruction Manual Instruction Manual Device type Pressure Output Galvanic isolated output T2314 RS232 - T2414 RS485 Device

More information

LBVR1718. Description. Features channel paperless recorder

LBVR1718. Description. Features channel paperless recorder LBVR1718 18 - channel paperless recorder Description It is the world first paperless recorder of the same size in highest resolution 640x480 pixels VGA TFT display, infrared detector, maximum 18 channels,

More information

Signal Isolators & Conditioners

Signal Isolators & Conditioners Analog Signal to RS485/232 Converter Signal Isolators & Conditioners (WJ21 series A/D Converter) Features: >> Analog signal acquisition, isolated RS-485/232 output >> 12-bit AD converter, testing accuracy>0.1%

More information

Masibus Automation And Instrumentation Pvt. Ltd.

Masibus Automation And Instrumentation Pvt. Ltd. User Manual 16 CHANNEL DIGITAL INPUT MODULE MASDI DI16 16D Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector25, Gandhinagar382044, Gujarat, India Phone No : 91 79 23287275

More information

OPERATING MANUAL FOR STREAM SELECTOR

OPERATING MANUAL FOR STREAM SELECTOR OPERATING MANUAL FOR STREAM SELECTOR Manufactured By: INSTRUMENTATION PVT. LTD. F-4 Memnagar complex, Opp. Petrol Pump Memnagar, Ahmedabad, India-380 052 Phone: +91-79-2749 5500/5600 FAX: +91-79-27417997

More information

Temperature/Process Controllers Manual

Temperature/Process Controllers Manual 3200 SERIES Temperature/Process Controllers Manual The innovative range of 3200 controllers offer precision control of temperature and other process variables together with a host of advanced features

More information

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

MRC 7000 Proven Recording Reliability that Became the Industry Standard! Data Sheet Recorder//Profiler DESCRIPTION The MRC7000 Recorder/ is a microprocessor based circular chart instrument capable of measuring, displaying, recording and controlling up to two process variables

More information

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

XT-9100 Technical Bulletin

XT-9100 Technical Bulletin System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX

More information

WLS-TC Specifications

WLS-TC Specifications Specifications Document Revision 1.0, February, 2010 Copyright 2010, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design.

More information

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4116MCM101(1445) For 4511 devices from ser. no:

4511 MODBUS RTU. Configuration Manual. Universal transmitter. No. 4116MCM101(1445) For 4511 devices from ser. no: 4511 MODBUS RTU Configuration Manual 4116 Universal transmitter 4116MCM101(1445) For 4511 devices from ser. no: 141590001 4116 CONTENTS Introduction... 1 Modbus basics... 1 Modbus RTU... 1 4511 Supported

More information

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS The MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS Mighty-5 DPM MODELS Micro-P & Mighty-1 Mighty-1 Micro-P ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters and

More information

20.4VDC to 28.8VDC with less than 10% ripple. Input impedance 10mSec typical, when used as normal digital inputs

20.4VDC to 28.8VDC with less than 10% ripple. Input impedance 10mSec typical, when used as normal digital inputs Vision OPLC V130-33-RA22 Technical Specifications This guide provides specifications for Unitronics model V130-33-RA22. General features include: 12 pnp/npn Digital, including 2 Analog, 2 PT100/TC, 1 HSC/Shaft-encoder

More information

User Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6. /8 DIN Process Indicators and Controllers C100, C150, C160 and V100

User Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6. /8 DIN Process Indicators and Controllers C100, C150, C160 and V100 User Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6 1 /8 DIN Process Indicators and Controllers C100, C150, C160 and V100 Electrical Safety This equipment complies with the

More information

DINALOG A 144 x 36 A1400 Light-Strip Indicator

DINALOG A 144 x 36 A1400 Light-Strip Indicator DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

DPR 100 A/B Analog Scales

DPR 100 A/B Analog Scales DPR 100 A/B Analog Scales 0I-6030 8/95 Pen and Multipoint 100 mm Digital Recorders Specification and Technical Data Introduction The DPR 100 is a microprocessor based 100 mm (4 inch) strip chart recorder

More information

User friendly and easy to program

User friendly and easy to program New Product Digital Panel Meter WPMZ User friendly and easy to program μm m/min mm rpm m/min ton Universal design! New Digital Panel Meter Specification is subject to change without notice Watanabe Electric

More information

Specifications

Specifications Specifications 18200-40 Cole-Parmer Instrument Company 625 East Bunker Court Vernon Hills, Illinois 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com e-mail: techinfo@coleparmer.com

More information

100mm Process Indicator Recorder

100mm Process Indicator Recorder Data Sheet SS/_3 100mm Process Indicator Recorder One or two pen continuous line 100mm recorder universal input for thermocouple, RTD, mv, ma and V Clear, 5-digit LED display high visibility, wide viewing

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

4511 MODBUS RTU. Configuration Manual. Universal trip amplifier. No. 4131MCM100(1402)

4511 MODBUS RTU. Configuration Manual. Universal trip amplifier. No. 4131MCM100(1402) 4511 MODBUS RTU Configuration Manual 4131 Universal trip amplifier 4131MCM100(1402) 4131 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 Supported Function Codes... 3 Modbus Parameters and

More information

SMARTRAIL X100 Protocol

SMARTRAIL X100 Protocol Smart Process & Control Ltd 11 Totman Close Brook Road Industrial Estate Rayleigh, Essex SS6 7UZ Customer Service: 01268 773422 www.smartprocess.co.uk SMARTRAIL X100 Protocol 1. SMARTRAIL X100 Protocol

More information

LE ELECTRONICS Pvt. Ltd.

LE ELECTRONICS Pvt. Ltd. LE ELECTRONICS Pvt. Ltd. Monitoring Relays: LVM Line Voltage Monitors LCM - Line Current Monitors VMR Voltage Monitoring Relays CMR Current Monitoring Relays VCMR Voltage Current Monitoring Relays LFM

More information

Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual TRANSMITTER T3413, T3417 Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual Instruction Manual for use of temperature

More information

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere!   Toll Free Digital Indicating Controllers JC Series High performance controllers...at the lowest prices anywhere! www.mod-tronic.com Toll Free 1-800 794-5883 Standard Features Structure Units available in standard

More information

Simplified information where and how you want it.

Simplified information where and how you want it. ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator

More information

Zenex-ultra Ultra Precision (0.01 C) Self-Tune PID Temperature Controller with Programmable Timer

Zenex-ultra Ultra Precision (0.01 C) Self-Tune PID Temperature Controller with Programmable Timer Ultra Precision (0.01 C) Self-Tune PID Temperature Controller with Programmable Timer CONTENTS 1. FRONT PANEL LAYOUT 1. BASIC OPERATION 3. PAGES & PARAMETERS 3 4. INSTALLATION PARAMETERS 5 5. CONFIGURATION

More information

Analog signal to RS485 or RS232 Converter, A/D Converter

Analog signal to RS485 or RS232 Converter, A/D Converter Analog signal to RS485 or RS232 Converter, A/D Converter Features: Analog signal acquisition, isolated RS-485/232 output 12-bit AD converter, testing accuracy>0.1% Can be remotely reconfigured for modules

More information