IVS 230 CD SEM. Product Catalog For the IVS 230 CD SEM

Size: px
Start display at page:

Download "IVS 230 CD SEM. Product Catalog For the IVS 230 CD SEM"

Transcription

1 IVS 230 CD SEM Product Catalog For the IVS 230 CD SEM

2 IVS 230 Product Catalog Rev 2 March 2000 Copyright 2000 Schlumberger ATE 45 Winthrop Street Concord, Massachusetts (978) Fax: (978) All rights reserved. No part of this publication may be reproduced in any form or by any electronic means, including information storage and retrieval systems, without permission in writing from Schlumberger ATE. Changes are made periodically to the information contained herein. These changes will be incorporated in new editions of this publication. NOTICE: The information contained in this catalog is believed to be accurate and reliable. However, Schlumberger ATE assumes no responsibility for any errors, omissions, or inaccuracies whatsoever. ii IVS 230 Confidential

3 The IVS 230 scanning electron microscope Offering the latest in metrology measurements and automation The IVS 230 SEM provides outstanding measurement precision for CD's and thin film head features and offers a fast, automated wafer loading system and fast pumpdown times. It allows operation at very low voltages for excellent measurements without image "bloom" or electron beam artifacts. Full digital beam control provides superior measurement accuracy and magnification stability. And the IVS 230 is truly "hands-free." No operator assistance is required during job plan execution. With its advanced measurement algorithms, it can measure CD's, contact holes, and thin film head features. It has a pattern recognition success of greater than 90 percent. And it has the smallest footprint of any metrology SEM. The new IVS 230 has been designed with these wide-ranging features to meet the needs of varied customers around the world. TYPES Confidential IVS 230 iii

4 About this catalog The IVS 230 catalog lists the hardware and software features available for the IVS 230 SEM. The purpose of this catalog is to inform you of just what is available on the IVS 230 SEM so you know what you can or cannot offer customers in the way of features and options. Other resources include the User's Guide and Maintenance Manual. Software Release Notes also provide important information on new software features. As release notes are received, they should be placed in this Product Catalog in the appropriate product section. iv IVS 230 Confidential

5 Table of Contents Measurement types... 1 Electron column and detection system... 2 Tool-to-tool matching... 4 Handler configurations... 5 Throughput... 6 Measurement options... 7 Measurement setup features... 8 Pattern recognition Configurations Focusing methods Data/image storage and output System protections, security and controls Vacuum systems System computer controls Options Weights, dimensions and facility requirements...19 Footprint Confidential IVS 230 v

6

7 Measurement types The IVS 230 SEM has many built-in algorithms to measure a wide variety of semiconductor and thin film head features. It measures line-space-pitch CD's and contact holes on semiconductor wafers. Special algorithms are also built-in for the thin film head industry to measure top pole and magneto-resistive (MR) features. Semiconductor measurements Measurable CD features are 0.1 to 20 microns with repeatability of <3 nm 3 sigma (or <1%, whichever is greater). Lines, spaces, and line/space pairs can be measured in X and Y direction in a single jobplan. The CD algorithm acquires the image within the measurement gate and does a grey scale profile analysis within the gate to find edges. Gate position and size are freely adjustable. Contact holes (CH) The Contact Hole algorithm provides X- width and Y-width measurements for round features. An ellipse approximation is drawn on the SEM image, connecting the four points found in determining the hole edges. This algorithm works well when holes are vertical. When contact holes do not have sharp vertical edges, the Adaptive Contact algorithm allows you to choose the top or bottom of the hole or a location in between to account for sidewall slope or irregularity. Thin film head measurements Top pole resist frame, MR stripe, MR leads-defining resist, MR leads final, coil resist and finals can be measured in the X direction and the Y direction within a single jobplan. CD measurement repeatability is <10 nm 3 sigma (or <1%, whichever is greater). As with semiconductor measurements, the CD algorithm acquires the image within the measurement gate and does a grey scale profile analysis within the gate to find edges. Gate position and size are freely adjustable during job setup. Runtime image filtering Measurement images can be filtered by 3 x 3, 5 x 5, or 7 x 7 kernels which allow you to manipulate grey scales to make bottoms more visible to the eye. Electronic ruler Manual measurements can be made quickly with on-screen images. Measurement results are output as X and Y distances. Measurement types Confidential IVS 230 1

8 Electron column and detection system The Schottky field emission electron gun allows for precise measurement of semiconductor and thin film head features at low voltages. Electron gun The electron gun is a thermally assisted field emission gun which allows good resolution at low voltages. Beam setpoint selection There are 10 user selectable beam setpoints. A beam setpoint is comprised of accelerating voltage, decelerating voltage, and condenser voltage. The landing energy (accelerating decelerating voltage) can range from 300eV to 2000eV although the most commonly used landing energies are between 500eV and 1000eV. Probe current Probe current range is 5 pa to 100 pa, continuous. Condenser voltage is used to adjust probe current. The Faraday cup is mounted in the stage. Image resolution <3.5 nm at 1 kv 6 nm at 500V Magnification The digital scan control system provides 25 magnification settings ranging from 1500x to 500,000x based on a 150 mm wide viewing image. Magnification is calibrated to a Schlumberger Standards wafer or to a customer preferred reference at the factory. Recalibration is usually not required. Also annual recalibrations are not required. Beam alignment Beam alignment is semi-automated with a wobble function built-in. Alignment is suggested once per shift for each beam setting, but it is possible to go for up to a week between alignments. Beam alignment is carried out using simple menu selections and digital encoder knobs located above the keyboard. Beam alignment knobs are activated only when selected in software. 2 IVS 230 Confidential

9 Stigmation An octapole stigmator is used for beam shape correction. Stigmation adjustments are suggested once per shift for each beam energy setting though it is possible to go up to a week between alignments. Like beam alignment, stigmation adjustments are made using simple menus and digital encoder knobs located above the keyboard. The stigmator knobs are operable only when activated by software. Detector system The Multichannel Plate (MCP) electron detector collects the electrons that form the image. Automatic MCP adjustment on each wafer matches wafer image brightness to images stored in the jobplan. SE (secondary electron) detection is used. The IVS 230 tracks illumination by jobplan and updates illumination based on user-defined limits. Focus system Focus coils in the column shape the beam to provide focus on measurement features. In addition to automatic focus, a manual focus knob controlled by software is provided at the keyboard. For more about focusing, see "Focusing methods" later in this catalog. Electron column and detection system Confidential IVS 230 3

10 Tool-to-tool matching IVS 230 systems can be matched to ensure that jobplans created on one system will run properly on another with the same results. Emergency stop button ON pushbutton (green) lit when on OFF pushbutton (red) lit when off lit when off (red) OFF pushbutton lit when on (green) ON pushbutton stop button Emergency Jobplans Matching systems Systems can be matched to 7.5 nm through a three-step process using the standard error of the Y-estimate. This process can be summarized as follows: Calibrate each system using the same standard wafer or measurement artifact at each of the measurement magnifications. Verify each system's magnification linearity by measuring a single feature across several magnifications (measurement vs. magnification: slope=0). Verify matching of multiple systems (tool A measurement vs. tool B measurement: slope=1.) 4 IVS 230 Confidential

11 Handler Configurations A fast robot wafer handler quickly loads and unloads wafers from the microscope stage. The robot with prealigner removes the wafer from a cassette, aligns it using its notch or flat, and places it on the stage in the orientation you specify. The next wafer is readied for placement on the stage during measurement. Different stage chuck configurations are available. Three cassette platforms Three cassette platforms are standard two for production wafers and one for wafer standards. Each platform can accommodate 100, 125, 150 and 200 mm cassettes without operator adjustment. Robot and prealigner The robot is an R, Z, theta pick-and-place robot with back side only vacuum contact. The prealigner is self-adjusting for mm wafers. Load angle error is ±0.25. Loading failure is <1:10,000 Special wafer protections If a cassette is removed from a platform while one of its wafers is being measured, the system gives a warning and asks you for information on how to return the wafer. It will also prompt you when an unusual event occurs, such as a power failure with wafers on the stage or robot, as to how you wish to proceed in returning the wafers to their proper slots. Stage chuck configurations There are three stage chuck configurations available. Standard configuration Stage accommodates mm SEMI standard wafers without operator adjustment. No hardware change required to mix SEMI standard wafers of any sizes (thin wafers only). Thick round substrates (optional) Stage can be configured for 6-inch round, thick substrates. No hardware change required to mix SEMI standard wafers of any size (thick or thin). Tool-to-tool matching Handler configurations Confidential IVS 230 5

12 Throughput The IVS 230 offers fast wafer throughput for semiconductor wafers and thin film head measurements. Semiconductor throughput Pipelined throughput is >35 wafers/hour (one site per die, five die per wafer). Linked measurement templates provide additional value by allowing more data to be collected per hour than a raw throughput number would indicate. Throughputs as high as 740 measurements per wafer at 4.5 wph have been obtained. With linked templates, multiple measurements can be made from a single acquired image with insignificant impact on wafer throughput. Linked templates also enhance data acquisition rates for thin film head customers. For more about linked templates, see "Measurement setup features." Thin Film Head Throughput Single wafer throughput is > 15 wafers/ hour (one site per die, 16 die per wafer). Pipelined throughput is >15 wafers/hour (one site per die, five die per wafer). 6 IVS 230 Confidential

13 Measurement options The IVS 230 measurement program is called a jobplan. When you set up a jobplan, you make all settings for the sites to be measured. The jobplan is set up on a typical wafer. Then, after checking results and modifying settings (if necessary), you can run the job plan for all of the wafers you want to measure. Jobplans Run your jobplan singly by executing the job in the Execute Jobplan menu. When the jobplan is finished, the system waits until you choose to run another job. The IVS 230 will automatically load a wafer, find and measure the sites you selected, then display and print the results. It then unloads the wafer and continues with another until all wafers in the jobplan are measured. Dynamic queues You can queue up to two job plans while a job plan is running. This way you don't even have to wait until a job is done before getting others ready to run. Use the Queue Dynamic Jobplan menu to queue the jobs without interrupting your jobplan. The jobplan stops running briefly while you queue up the new job or jobs. Queues Put up to 15 jobplans in a queue, then the IVS 230 will run all these jobplans one after the other uninterrupted. Throughput Measurement options Confidential IVS 230 7

14 Measurement setup features The IVS 230 allows wide flexibility in setting up jobplans. One reason for this is the use of templates in setting up jobplans. They make jobplan setup fast and easy. And they also allow you to easily incorporate the same measurement information in other jobplans so you don't always have to start jobplans from scratch. Measurement Gate : X PROFILE Scan MEAS Direction : X 100 I n t e n s i t y 0 X position Templates Jobplan templates allow you to set parameters for a typical site, then you can assign this template to all the sites you want to measure. Jobplan templates speed up job plan setup. They allow a great deal of flexibility since they can be assigned to any site in a jobplan and copied to other jobplans. IVS 230 jobplans give you maximum control over measurements. You can set up easily but you still have many setup options available so your jobplans can be as simple or as complicated as you want. You can measure different types of sites using many templates or you can just measure all the same sites using one template. You can have up to 200 sites in a jobplan. Ten templates per jobplan You can set up to ten unique measurements in a jobplan. You set the measurement parameters for the site in a template, then simply assign that template to as many of the sites you want to measure. For instance, you can have critical dimension (CD) measurements and contact hole or pole measurements in a single jobplan. Just assign the appropriate template to the site you wish to measure. 8 IVS 230 Confidential

15 Linked templates Going one step beyond the concept of templates described on the previous page, linked templates allow you to make different measurements at the same site faster. With linked templates, the system uses a single acquired image to make multiple measurements. Linked templates can greatly increase the amount of essential data collected with an insignificant impact on throughput. Second and subsequent measurements at a site require only 0.2 seconds per measurement. Matrix site setup If your sites are symmetrically located on the die, you can create a site matrix to measure the entire set with a simple setup operation. You can create a matrix of any number of rows and columns, then select only those rows and column you want to measure. For instance, choose sites in every third row and every third column to measure. With proportionally spaced sites, site selection is fast and easy using matrix site setup. Brick Laying By offsetting rows or columns of die, more die can be packed onto a wafer. Using the brick laying function, you can rearrange the wafer map for the offset rows or columns so that it can move to the offset die as easily as to die in the standard matrix pattern. Using brick laying, you can plug in an offset value for any row or column or drive to the offset row or column using the joystick and let the tool calculate the offset for you. A single wafer map may have offset rows or columns but not both. IVS 230 wafer map before brick laying Measurement setup features After brick laying Confidential IVS 230 9

16 Pattern recognition The IVS 230 uses light optical images for global wafer alignment. SEM images are used to more accurately align to the die pattern (die pattern recognition). And pattern recognition near the measurement site (intermediate pattern recognition) ensures that the intended feature is measured. There is also an optional site pattern recognition choice for high mag positioning (75,000X) and contact holes. Filtered grey algorithm The filtered grey algorithm is used on the CD SEM for pattern recognition. It is especially good for low contrast images and thin edges or features where you need to filter out grain or noise. It is also useful if conditions change from site to site. It is designed to detect vertical and horizontal lines only. 2 C Optical global alignment An optical microscope in the wafer chamber allows fast global alignment since it can finish global alignment before pumpdown is complete. The wafer can already be positioned for measurements when pressure is low enough for electron beam operation. There are two selectable optical magnifications, the 150x and 500x. Scan shift Scan shift is a fast, precise way of aligning to the measurement site. First the system moves to the die pattern and finds it. Then the system moves to the site location, but it scan shifts (beam electronically deflected) to find the site pattern. It aligns to the pattern, then scan shifts back so the measurement gate will be aligned to within one pixel of the designated measurement location. With scan shift, stage movements are eliminated and site pattern recognition is fast and precise. The scan shift site pattern recognition feature may be up to 100 microns away from the site in X and Y. 10 IVS 230 Confidential

17 Focusing methods The IVS 230 has both automatic and manual focusing. For automatic focusing, the IVS 230 identifies the focal plane where contrast of the selected feature edge is at a maximum. The manual focus knob is located to the right of the keyboard and can be used for manual tasks. Focus gate Focusing methods To set up for automatic focus during job plan execution, you place a focus gate around a feature edge. The system applies the focus algorithm to this edge, adjusting the focus coils to find maximum edge contrast. The focal length that provides the maximum contrast value is the focus setting. Focusing features Automatic and manual focus. Automatic focus gate is freely adjustable for size and position. Automatic focus uses maximum edge contrast. Manual focus control using digital encoder knob. Focus knob does not function unless activated through software selection. Pat recognition types Focusing methods Confidential IVS

18 Data/image storage and output Measurement data can be output to a printer, to the hard drive, floppy, or to your network. Statistics (mean, max, min, range, sigma, success) can be reported by site, wafer, and lot. Statistics can be shown by type (CD) or by template. Other special data collection and storage features are described below. D# S# Type Mean Max Min Range S(n-1) n 1 1 "CD" "CD" "CD" "CD" "CD" "CD" "CD" "CD" Image storage Images can be stored in a variety of useful formats including TIF, JPG, BMP, and proprietary 16-bit format for off-line measurements. Run Time Image Storage If a measurement error occurs at a site for any reason, you can store the image of this site for later analysis. The system will store the image and an associated data file giving you details about what happened including the error reported and date and time of the measurement error. This allows a closer look at the features in question to determine why the error may have occurred a problem at the site, a problem with job setup, etc. The image can be saved in TIFF or 16-bit format. Printer The printer is a cleanroom compatible Mitsubishi P68U thermal printer for printing images and data. 12 Viewing screen The IVS 230 has a color monitor for viewing images and displaying control and status functions. Pattern recognition and measurement site images are displayed during job execution. Data is displayed during job execution and may be viewed when the job is done. A graphical vacuum status window displays the status of pumps, valves and gauges, shows cassettes being used, and shows wafer location in the wafer chamber. Network connection The IVS 230 is Ethernet compatible through Novel Netware for network storage of data, images and jobplans (network card not provided). Data caching If measurement data is sent to a network instead of storing it on the system, the IVS 230 will automatically create a cache on the system hard drive to store the data if the network is down or the system can't connect for some other reason. This ensures that no data is ever lost. IVS 230 Confidential Throughout Data collection, storage

19 System protections, security and controls The IVS 230 has built-in protections to prevent unauthorized access and to prevent improper operation. System protections Dedicated system controller circuitry protects wafers and the system in the event of a power interruption. System logic rigorously ensures that valves and electronics are not operated in an unsafe manner. Certain actions are not allowed by the system except when carried out in the proper sequence, protecting wafers, pumps, and valves. Security The IVS 230 has the following built-in security systems: User passwords User passwords prevent unauthorized access. Six password levels can be assigned from operator up to service and supervisor. Only the person with supervisor privileges has access to the Password program to make changes. Locked circuit box The main system circuit box is protected by lock and key. Wafer chamber lid The wafer chamber opening mechanism is protected by lock and key. Logic driver board Firmware constantly checks system electronics and vacuum to monitor system functions. It prevents anyone from operating valves in an improper sequence and prevents mishandling of wafers. Software algorithms provide additional protection. Data/image storage System protections Confidential IVS

20 Vacuum systems The vacuum system provides fast, automated pumpdown of the wafer chamber without using a loadlock. Wafer chamber pumping The automated pumping system uses two turbomolecular pumps and two roughing pumps to evacuate the wafer chamber. Wafers are loaded directly into the wafer chamber without the need for a prepumping loadlock. Pumps Pumps used are: Roughing pumps Two dry pumps standard Turbomolecular pumps Two high throughput turbomolecular pumps standard. No maintenance required. Ion pumps There is one ion pump for the electron gun and one for the intermediate section of the electron column. No maintenance required. Cleanliness Class l compatible 0.01 particles added per square centimeter, per wafer pass, measuring particles< 0.3 microns System exterior consists of hinged and removable stainless steel panels 14 IVS 230 Confidential

21 System computer controls The system controller in the IVS 230 provides dependable control with a tape backup and network connections (optional). Colorado Backup-DOS File View Options Utilities Help! Backup Restore Compare Exit Software Main Menu Quick Start Reference BACKUP Click on the Backup button or key <Alt- B> to copy files. RESTORE Click on the Restore button or key <ALT-R) to copy files from tape to any drive destination. COMPARE Click on Compare button or key <Alt-P> to compare files on tape to files on disk. <Alt-Letter> selects menu pulldown <Tab> moves around dialog box Tape drive The IVS 230 is supplied with a tape drive for backup of the system hard drive. It allows fast, dependable backups for the large amounts of files that customers build up on their systems. A Jumbo tape drive supplied with the IVS 230 allows backup of 5 GB per cartridge (compressed). Tape drive software allows you to back up all files or only those files that have not been backed up before (incremental backups) Cartridges can be linked if a backup is ever larger than a single tape's capacity. System controls Industrial computer with Intel Pentium processor. DOS-based user interface and control system. 101-key keyboard for keyboard control and command entry. Joystick for manual stage motion control. Digital encoder knobs for beam alignment and stigmator functions. Vacuum systems System computer controls Confidential IVS

22

23 Options This section details the special applications or features available with the IVS 230. These features are optional. They offer additional capabilities for our customers with special needs or requirements. Remote Job Generator Remote Job Generator (RJG) allows you to easily create job plans for new devices of an existing process on a PC, freeing up valuable machine time for production measurements. You just need to create job plans on the tool for one device in the process. Then you can download all these job plans to the Remote Job Generator on your PC. Create new job plans for your next device right on the PC and send them back to the tool. The job plans will be ready to run for the new device. You've created the new job plans without taking the system out of production and with the convenience of creating job plans outside the fab right on your own PC. This allows the job plan to be created before the wafer is available for measurement, significantly reducing work in process hold times. System requirements The Remote Job Generator tools can be run on any desktop computer running Windows NT 4.0 and Internet Explorer 4.0. The tool can be running any version of the system software. Remote Job Generator is capable of reading and writing only job plans that have the center of the die as the die origin. They cannot use a pattern recognition site for the die origin. In order to quickly upload and download job plans from the system, the PC and tool should be connected Remote Job Generator Confidential IVS

24 Options to a network. This is not necessary, however. Job plans can be transferred using floppy disks. RJG CD cells The CD cell is a unique feature of RJG and is not part of the software on the tool. The cell is an array of CD features that are placed around the die. See illustration below. In order to set up a cell, you must know the location of each of the features relative to a cell origin. Then the cell origin can be located anywhere within the die. Based on the cell origin and the offset from the cell origin to each of the features, the system calculates the locations of the features. You assign measurement templates from the existing job plans for each process layer to cell features in RJG. When an RJG-created job plan is run on the system, the selected feature in the cell is measured using the gate placement and focusing method set up in the template. CD cells do not have to be used, but they do provide powerful features. For instance, if you change the location of the cell, the locations of each of the features within the cell are automatically updated. Upper left corner Die CD cell Cell left; shown in street on wafer (right) 18 Confidential IVS 230

25 Specifications Weights, dimensions, and facility requirements Dimensions Measurement module 70 in. (height) x 65 in. (width) x 38 in. (depth) cm (height) x cm (width) x 96.5 cm (depth) Control console 60 in. (height) x 25 in. (width) x 33 in. (depth) cm (height) x 63.5 cm (width) x 83.8 cm Depth with keyboard open: 43 in. (109.2 cm) System footprint Weight With control console wall mounted: 19 sq. ft. (1.7 sq. m.) With control console not wall mounted: 23 sq. ft. 2.1 sq. m.) 2500 lbs (1035 kg); shipping weight approx lbs (1215 kg) Power Ground Air Nitrogen 208V, 50/60 Hz, 40 amp, three phase, computer grade power (NEMA #L21-30 plug) Roughing pumps: two 208V, 50/60 Hz, 20 amp, single-phase circuits (NEMA #L21-20P plug) Meets VDE and BS specifications >90 psi, 3 cfm, hose fitting 1/4 in. o.d., oil free dry filtered down to 3 micron particle size 40 psi, 10 cfm, hose fitting 3/8 in. o.d. Chilled Turbo pumps: 0.6 gpm, 60 F ± 5 F (stable to ±2 F at nominal water value); hose fitting 0.25 in. O.D. x 0.17 in. I. D. Roughing pumps: 0.8 gpm, hose fitting 0.63 in. O.D. x 0.38 in. I.D. 60 PSI nominal value (non DI) water Weights, dimensions Remote Job Generator Vacuum for wafer handler Exhaust -24 to -27 in. HG, 0.8 cfm, hose fitting 1/4 in. o.d. Clean dry air: Atmosphere to -10 in. Hg, 2 cfm, 0.375" O.D. Roughing pumps: Atmosphere, 59 cfm/pump, KF40 fitting Confidential IVS

26 Specifications Temperature 65 to 75 F, ±1 F Range (18 to 24 C, ±0.5 C) Humidity Vibration EMI Acoustic 35 to 80 percent (non-condensing, stable to ±5 percent) Should not exceed 2.0 microns peak-to-peak; 0.7 microns rms Should not exceed 5 mg peak; 1 mg rms Should not exceed 75 dbc Weights and measures 20 IVS 230 Confidential

27 Footprint 2" (5.08 cm) dia. leveling pad 4 places 2" (5.08 cm) dia. caster swivel radius 1" (2.54 cm) 4 places Operator console (71.88) (55.62) (83.82) XX.XX = inches (XX.XX) = centimeters FRONT (48.31) (50.85) (62.53) 1.12 HEX levelling pads 3" (7.62 cm) dia. caster swivel radius.69" (1.75) 4 places Footprint Specifications (78.74) (96.52) (49.86) Measurement module FRONT 3.50 (8.89) (131.45) (165.10) Confidential IVS

28

200 mm Semi-automated Probe System with BlueRay Technology

200 mm Semi-automated Probe System with BlueRay Technology PA200BlueRay 200 mm Semi-automated Probe System with BlueRay Technology DATA SHEET The sets a new standard for high-speed accuracy. Its precision ensures smooth probe landing with safe, repeatable electrical

More information

2.2. Facilities Requirements

2.2. Facilities Requirements 2.2. Facilities Requirements Facilities requirements for the alpha-se system are listed in Table 2-1 and the system dimensions are given in Figure 2-1. As shown in Figure 2-2, the preferred clear work

More information

Raith e_line Electron Beam Lithography

Raith e_line Electron Beam Lithography Raith e_line Electron Beam Lithography Standard Operating Procedure 1 (For an un-patterned sample) Revision: 7.0 Last Updated: Feb.18/2015, Revised by Mohamad Rezaei Overview This document will provide

More information

Probe station system

Probe station system Probe station system Manufacturer: Micromanipulator Mode: 450PM-HR Descriptions: The Model 450PM 8 probe station offers stable and reliable probing performance. It is based on a design of Micromanipulator

More information

SmartSoft AES Operator s Guide

SmartSoft AES Operator s Guide SmartSoft AES Operator s Guide Part No. 702064 Rev. A Physical Electronics USA, PHI, SMART-Tool, SmartSoft, MultiPak and Watcher are trademarks of ULVAC-PHI, Inc. All other trademarks are the property

More information

Scanned by CamScanner

Scanned by CamScanner Scanned by CamScanner Scanned by CamScanner Annexure I Name of the equipment: Field Emission Scanning Electron Microscope (FE-SEM) along with Energy Dispersive Spectroscope (EDS) and accessories. Technical

More information

Beam Position Monitor For High Energy Particle Beams

Beam Position Monitor For High Energy Particle Beams Beam Position Monitor For High Energy Particle Beams Features 16 by 16 strip ionization chamber sensor High vacuum compatible Small insertion length (152.4 mm) Robust thin steel foil vacuum windows Very

More information

Introduction of Hitachi SU1510

Introduction of Hitachi SU1510 Introduction of Hitachi SU1510 1 1. Main Features of the SU1510 SU1510 Same high-performance optics as S-3400N Variable Pressure mode as standard Large samples up to 153mm in diameter (observation range

More information

TRIBOMETERS MICRO-MACRO TRIBOLOGY TESTING

TRIBOMETERS MICRO-MACRO TRIBOLOGY TESTING TRIBOMETERS MICRO-MACRO TRIBOLOGY TESTING The Tribometer provides highly accurate and repeatable wear friction testing in rotative and linear modes compliant to ISO and ASTM standards. Designed, at the

More information

NXQ8000 Series Mask Aligner

NXQ8000 Series Mask Aligner NXQ8000 Series Mask Aligner The NXQ8000 Production Mask Aligner and Front to Back Overlay Inspection System integrates the latest in Robotic Automation with state of the art next generation alignment stage

More information

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE OV1000 Part No. 23624 OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE PRODUCT OVERVIEW User Guide: OV1000 OV1000 HEIGHT ADJUSTABLE TABLE A healthier work environment starts with the option to sit or stand throughout

More information

in-built Vacuum Pick-up for large SMD ICs RS232 to USB interface for direct connection to PC

in-built Vacuum Pick-up for large SMD ICs RS232 to USB interface for direct connection to PC Hi-End Hi-features rich 3-in-1 SMT/PTH Rework System Model MFRS-500SUSB reliable & caring since 1976 in-built Vacuum Pick-up for large SMD ICs RS232 to USB interface for direct connection to PC LEAD RoHS

More information

TA Instruments Installation Requirements for Microcalorimeter Systems

TA Instruments Installation Requirements for Microcalorimeter Systems TA Instruments Installation Requirements for Microcalorimeter Systems Thank you for ordering a Microcalorimeter system from TA Instruments. To ensure that installation of that system goes as smoothly as

More information

Advances in Disk Metrology

Advances in Disk Metrology Advances in Disk Metrology Robert Kertayasa Zeta Instruments March 2011 www.zeta-inst.com 1909 Concourse Drive San Jose CA 95131 PHONE (408) 577-1888 FAX (408) 577-0588 Agenda Introduction Technology Sample

More information

VERTICAL CONTROL LASER OWNERS MANUAL

VERTICAL CONTROL LASER OWNERS MANUAL Rev: 4.5.18 VERTICAL CONTROL LASER OWNERS MANUAL P/N 3003-1041 1810 SE First Street, Suite H, Redmond, OR 97756 Phone: 541-548-0882 Fax: 541-548-0892 Email: laserline@laserline.net Website: www.laserlinemfg.com

More information

APS/SPS200TESLA. 200 mm Fully-automated On-Wafer Probing Solution for High-power Devices

APS/SPS200TESLA. 200 mm Fully-automated On-Wafer Probing Solution for High-power Devices 00 mm Fully-automated On-Wafer Probing Solution for High-power Devices DATA SHEET The is the industry s first fully-automated on-wafer probing solution focused on production performance for high-power

More information

Title: Heidelberg DWL66+ Semiconductor & Microsystems Fabrication Laboratory Revision: B Rev Date: 05/03/2017

Title: Heidelberg DWL66+ Semiconductor & Microsystems Fabrication Laboratory Revision: B Rev Date: 05/03/2017 Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the Heidelberg DWL66+. All users are expected to have read and understood this document.

More information

Denton Vacuum Phoenix 400 Continuous In-Line Sputtering Deposition System General Specifications

Denton Vacuum Phoenix 400 Continuous In-Line Sputtering Deposition System General Specifications Phoenix 400 Continuous In-Line Sputtering Deposition System s Phoenix 400X System Overview Denton Vacuum s Phoenix 400X Continuous In-Line Sputtering system provides users optimal uniform coating thicknesses

More information

TA Instruments Installation Requirements for Microcalorimeter Systems

TA Instruments Installation Requirements for Microcalorimeter Systems TA Instruments Installation Requirements for Microcalorimeter Systems Thank you for ordering a Microcalorimeter system from TA Instruments. To ensure that installation of that system goes as smoothly as

More information

Customer Responsibilities

Customer Responsibilities For Research Use Only. Not for use in diagnostic procedures. Thank you for purchasing the Agilent G5590A BenchCel Workstation. To get you started and to assure a successful and timely installation, please

More information

SGT-600 SAFETY GROUND TESTER

SGT-600 SAFETY GROUND TESTER SGT-600 SAFETY GROUND TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 April 2015 Revision 1.0 SAFETY

More information

University of Minnesota NanoFabrication Center Standard Operating Procedure

University of Minnesota NanoFabrication Center Standard Operating Procedure Equipment Name: JEOL SEM Coral Name: jeol-sem Revision Number: 4 Model: JSM-6610LV Revisionist: K. Roberts Location: Area 3 Date: 9/17/2013 1 Description The JSM-6610LV is a scanning electron microscope

More information

TA Instruments Installation Requirements for Microcalorimeter Systems

TA Instruments Installation Requirements for Microcalorimeter Systems TA Instruments Installation Requirements for Microcalorimeter Systems Thank you for ordering a Microcalorimeter system from TA Instruments. To ensure that installation of that system goes as smoothly as

More information

Chapter 31 Using the Optical Character Reader

Chapter 31 Using the Optical Character Reader Chapter 31 An Optical Character Reader can be used with the IVS 155 to scan wafer ID s. The OCR Reader scans the ID on a wafer, and the AccuVision software reports the wafer ID character string to GEM.

More information

MPI TS150-AIT 150 mm Manual Probe System

MPI TS150-AIT 150 mm Manual Probe System MPI TS150-AIT 150 mm Manual Probe System Industry s first explicitly designed 150 mm probe system providing accurate tests for mm-wave, THz, and automated impedance tuner applications FEATURES / BENEFITS

More information

Immersion Scanning Systems

Immersion Scanning Systems Immersion Scanning Systems L S - 2 0 0 X S E R I E S Probe manipulator The affordable full-featured immersion-scanning system PRODUCT FEATURES Features Applications Product Description Performance Envelope

More information

501, , 1052, , 1602, 1604 EXCEL EXCEL 1602UC EXCEL 1052UC EXCEL 501HC. Micro-Vu Corporation. Precision Measurement Systems

501, , 1052, , 1602, 1604 EXCEL EXCEL 1602UC EXCEL 1052UC EXCEL 501HC. Micro-Vu Corporation. Precision Measurement Systems 501, 502 1051, 1052, 1054 1601, 1602, 1604 1602UC 1052UC 501HC Precision Measurement Systems 501, 502 1051, 1052, 1054 1601, 1602, 1604 Excel 501 HM/HC Excel 502 HM/HC Excel 501 Excel 502 Scale Resolution

More information

Linear Positioning Stage Reference Manual

Linear Positioning Stage Reference Manual PP-30 Series Linear Positioning Stage PP-30 Piezo Positioner Stage Rev 3.00 MICRONIX USA, LLC 15375 Barranca Parkway, E-106 Irvine, CA 92618 Tel: 949-480-0538 Fax: 949-480-0538 Email: info@micronixusa.com

More information

Standard Operating Procedure FEI Quanta 200 Scanning Electron Microscope

Standard Operating Procedure FEI Quanta 200 Scanning Electron Microscope Standard Operating Procedure FEI Quanta 200 Scanning Electron Microscope This document is intended as a guide to the operation of the FEI Quanta 200ESEM by certified users. It provides details on sample

More information

MPI TS150-THZ 150 mm Manual Probe System

MPI TS150-THZ 150 mm Manual Probe System MPI TS150-THZ 150 mm Manual Probe System Industry s first explicitly designed probe system for accurate measurements at mm-wave and sub-mm wave (THz) frequency range FEATURES / BENEFITS Variety of Applications

More information

Length, Germany, PTB (Physikalisch-Technische Bundesanstalt)

Length, Germany, PTB (Physikalisch-Technische Bundesanstalt) Laser radiations Laser radiations Laser radiations Laser radiations Length Length Frequency stabilized laser (He- Ne): vacuum wavelength Frequency stabilized laser (He- Ne): absolute frequency Frequency

More information

Ultralow temperature freezers -86 C. Platilab & Irilab Series

Ultralow temperature freezers -86 C. Platilab & Irilab Series Ultralow temperature freezers Platilab & Irilab Series ANGELANTONI LIFE SCIENCE propose a wide range of ultralow temperature freezers, from 110 to 800 liters, chests and uprights kind. This brochure includes

More information

evue Digital Imaging System DATA SHEET FEATURES / BENEFITS

evue Digital Imaging System DATA SHEET FEATURES / BENEFITS evue Digital Imaging System DATA SHEET The evue digital imaging system is optimized for on-wafer test with Cascade Microtech s probe stations. The revolutionary multi-optical path, multi-camera design

More information

JSM-7900F. Scientific / Metrology Instruments. Schottky Field Emission Scanning Electron Microscope. Ultimate Analytical tool

JSM-7900F. Scientific / Metrology Instruments. Schottky Field Emission Scanning Electron Microscope. Ultimate Analytical tool Scientific / Metrology Instruments Schottky Field Emission Scanning Electron Microscope Ultimate Analytical tool JSM-7900F High-Performance FE-SEM successfully combining ultrahigh resolution and unprecedented

More information

Mini Photoelectric Sensor

Mini Photoelectric Sensor Mini Photoelectric Sensor High cost-performance Mini Photoelectric Sensor Saves Installation Space and Wiring Effort and Detects Minute Sensing Objects Pin-point beam (1 to 2-mm dia.) makes it possible

More information

Relative humidity Noise level 4-7" reels: 8-72 mm tapes 11-15" reels: 8-72 mm tapes Max. 3.5 kg

Relative humidity Noise level 4-7 reels: 8-72 mm tapes 11-15 reels: 8-72 mm tapes Max. 3.5 kg Cubus Version 3.2 / May 2017 Configuration Standard Configuration Cubus Machine type Standalone Stacks Flexible stacks for reel storing, adjustable by customer Reel detection Automatic diameter, width

More information

DRILLING SERIES MULTISTATION EVOLUTION LZ NEW HIGH SPEED MODULAR MICRODRILLING STATION

DRILLING SERIES MULTISTATION EVOLUTION LZ NEW HIGH SPEED MODULAR MICRODRILLING STATION DRILLING SERIES MULTISTATION NEW HIGH SPEED MODULAR MICRODRILLING STATION ALL AXES WITH LINEAR MOTORS MULTISTATION IS THE MOST SUITABLE UNIT FOR ANY POSSIBLE DRILLING/ROUTING APPLICATION MULTISTATIONO

More information

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems Features General Universal Application Data Processing Telecommunications Medical/Health Care Manufacturing/ Process Control Quality Design

More information

Product Specifications

Product Specifications Product Specifications The ksa RateRat Pro is a turnkey, real-time, in-situ optical reflectance probe designed for deposition monitoring of semi-absorbent thin films. The RateRat Pro measures deposition

More information

DEFLECTION AND TWIST MEASUREMENT SYSTEM (DTMS) Model 47

DEFLECTION AND TWIST MEASUREMENT SYSTEM (DTMS) Model 47 Features DEFLECTION AND TWIST MEASUREMENT SYSTEM (DTMS) Model 47 Results are not affected by the motion or acceleration of the structure being tested Three or five degrees of freedom are measured between

More information

LEXT 3D Measuring LASER Microscope

LEXT 3D Measuring LASER Microscope LEXT 3D Measuring LASER Microscope Warning: This instrument may only be operated by those who have been trained by AAF staff and have read and signed the AAF laboratory policies. A) STARTUP 1. Computer

More information

ACCURACY, SPEED, RELIABILITY. Turnkey Production for: MEMS. Multi-Chip Modules. Semiconductor Packaging. Microwave Modules.

ACCURACY, SPEED, RELIABILITY. Turnkey Production for: MEMS. Multi-Chip Modules. Semiconductor Packaging. Microwave Modules. >> Turnkey Production for: MEMS Multi-Chip Modules Semiconductor Packaging Microwave Modules Flip Chip Photonics Packaging ACCURACY, SPEED, RELIABILITY ULTRA-PRECISION ASSEMBLY WORK CELL Turnkey production

More information

ABM's High Resolution Mask Aligner Features:

ABM's High Resolution Mask Aligner Features: ABM's High Resolution Mask Aligner is a very versatile instrument with interchangeable light sources which allow Near-UV (405-365 nm) as well as Mid- and Deep-UV (254 nm, 220 nm) exposures in proximity

More information

Industrial pressure controller Model CPC4000

Industrial pressure controller Model CPC4000 Calibration technology Industrial pressure controller Model CPC4000 WIKA data sheet CT 27.40 Applications Oil and gas industry Industry (laboratory, workshop and production) Transmitter and pressure gauge

More information

NSCRIPTOR DPN System Product Data Sheet

NSCRIPTOR DPN System Product Data Sheet NSCRIPTOR DPN System Product Data Sheet NSCRIPTOR DPN System Reference: DS006 Dip Pen Nanolithography (DPN) is the process of writing stable nanoscale patterns of molecular "ink" onto a sample substrate

More information

12X Zoom. Incredible 12X (0.58-7X) magnification for inspection of a wider range of parts.

12X Zoom. Incredible 12X (0.58-7X) magnification for inspection of a wider range of parts. Incredible 12X (0.58-7X) magnification for inspection of a wider range of parts. Telecentric attachment gives you the world s first parfocal telecentric zoom lens with field coverage up to 50 mm. Increased

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A CSM_ES-A_DS_E Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection

More information

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual FG-7000T Digital Torque Gauge Operation Manual SHIMPO INSTRUMENTS Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the

More information

SEM topography. Live quantitative surface topography in SEM

SEM topography. Live quantitative surface topography in SEM SEM topography Live quantitative surface topography in SEM 2 Measure surface topography with SEM. n Use conventional segmented BSE signals. n Get immediate feedback with automated topographic reconstruction.

More information

MPI TS2500-RF 200 mm Fully Automated Probe System For RF Production Test Measurements

MPI TS2500-RF 200 mm Fully Automated Probe System For RF Production Test Measurements MPI TS2500-RF 200 mm Fully Automated Probe System For RF Production Test Measurements FEATURES / BENEFITS Designed for Wide Variety of RF On-Wafer Production Applications RF applications up to 67 GHz &

More information

Operating Procedure for Horiba Raman Microscope

Operating Procedure for Horiba Raman Microscope Operating Procedure for Horiba Raman Microscope SAFETY Be aware of Laser radiation at all times! Do not remove the covers of the instrument. Components are supplied with 110V electric source. Do not touch

More information

Inspiron Series. Views. Specifications

Inspiron Series. Views. Specifications Inspiron 17 5000 Series Views Copyright 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell and the Dell logo are trademarks

More information

Made in Italy INSPECTA COMBO X-RAY DRILLER - ROUTER ASSISTED BY X-RAY OPTIMIZATION

Made in Italy INSPECTA COMBO X-RAY DRILLER - ROUTER ASSISTED BY X-RAY OPTIMIZATION Made in Italy DRILLER - ROUTER ASSISTED BY OPTIMIZATION ALL LINEAR MOTORS The latest and most flexible x-ray unit for drilling / routing. INSPECTA COMBO High speed drill/rout air bearing spindles 20,000

More information

Discovery SDT650. Site Preparation Guide. Revision A Issued March Page 1

Discovery SDT650. Site Preparation Guide. Revision A Issued March Page 1 Discovery SDT650 Site Preparation Guide Revision A Issued March 2017 Page 1 Table of Contents Table of Contents... 2 Ideal Setup... 3 System Components... 4 Instrument Measurements... 5 Utility Requirements...

More information

ezimagex2 User s Guide Version 1.0

ezimagex2 User s Guide Version 1.0 ezimagex2 User s Guide Version 1.0 Copyright and Trademark Information The products described in this document are copyrighted works of AVEN, Inc. 2015 AVEN, Inc. 4595 Platt Rd Ann Arbor, MI 48108 All

More information

Tribometers. nanovea.com

Tribometers. nanovea.com Tribometers The Nanovea Tribometer offers precise and repeatable wear and friction testing using rotative and linear modes on a single system. Designed, at the core, with a high quality motor and a 20bit

More information

Printer specifications

Printer specifications STUDIO SYSTEM Printer specifications The printer was designed from the ground-up for simple installation and use. Its process is similar to the safest, most widely used 3D printing process Fused Filament

More information

Equipment Standard Operating Procedure Kimberly Appel

Equipment Standard Operating Procedure Kimberly Appel Date Created: June 26, 2004 Date Modified: The Flexus 2320 Equipment Standard Operating Procedure Kimberly Appel 1. Purpose 1.1. The Flexus Thin Film Stress Measuring Apparatus (TFSMA) measures the changes

More information

Spectrum S-920N-C Cleanroom Series

Spectrum S-920N-C Cleanroom Series Spectrum S-920N-C Cleanroom Series Scalable solutions for high-volume manufacturing and assembly Features and Benefits Third-party certified for Class 100 compliance Stainless steel enclosure has a passivated

More information

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering

More information

Automated High Pressure Calibrator Model CPC 8000

Automated High Pressure Calibrator Model CPC 8000 Calibration Technology Automated High Pressure Calibrator Model CPC 8000 Mensor Data Sheet CPC 8000 02/2012 Applications Calibration of industrial pressure instruments Pressure transmitter manufacturers

More information

CI-150 Series. Airborne Particle Counters

CI-150 Series. Airborne Particle Counters CI-150 Series The CLiMET CI-150 series of full-featured airborne particle counters are the smallest, lightest and fastest counters with unsurpassed ease of use. It is the smallest and lightest 1.0 CFM

More information

Accumeasure TM Capacitance Probes

Accumeasure TM Capacitance Probes MTI Instruments Flat Capacitance Probes Accumeasure TM Capacitance Probes for Accumeasure TM D series MTI Instruments Flat Capacitance Probes for Grounded Targets MTI s flat capacitance probe series. The

More information

AVR Series 120V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port

AVR Series 120V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port AVR Series 120V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port MODEL NUMBER: AVR550U Highlights 550VA ultra-compact 120V line interactive UPS Corrects brownouts and overvoltages from 83V to

More information

A New Generation of Reliability FOM2 NT. FO3015M2NT Laser Cutting System

A New Generation of Reliability FOM2 NT. FO3015M2NT Laser Cutting System A New Generation of Reliability FOM2 NT FO3015M2NT Laser Cutting System Development Concept FO3015NT Proven Machine. Leading-Edge Technology. The FOM2NT laser represents the third generation of Amada s

More information

Residual Gas Analyzers XT Series

Residual Gas Analyzers XT Series Residual Gas Analyzers XT Series Extorr XT Series Residual Gas Analyzers The Extorr XT systems are ideal for gas analysis, leak detection and vacuum processing applications. These reliable, easy to use

More information

LifeSize ClearSea Installation Guide August 2012

LifeSize ClearSea Installation Guide August 2012 LifeSize ClearSea Installation Guide August 2012 LifeSize ClearSea LifeSize ClearSea Virtual Machine LifeSize ClearSea Installation Guide 2 LifeSize ClearSea This guide describes how to install and configure

More information

GENERAL SPECIFICATIONS FOR SINGLE-SPINDLE SEMI AUTOMATIC DICING MACHINE MODEL: SS20PLUS

GENERAL SPECIFICATIONS FOR SINGLE-SPINDLE SEMI AUTOMATIC DICING MACHINE MODEL: SS20PLUS 20-May.2015 GENERAL SPECIFICATIONS FOR SINGLE-SPINDLE SEMI AUTOMATIC DICING MACHINE MODEL: SS20PLUS Make Approval 新井 '15/06/04 ( 裕 ) TOKYO SEIMITSU CO., LTD. TOKYO, JAPAN - The contents of this manual

More information

OV1001 Part No OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE

OV1001 Part No OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE OV1001 Part No. 23620 OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE PRODUCT OVERVIEW User Guide: OV1001 OV1001 HEIGHT ADJUSTABLE TABLE A healthier work environment starts with the option to sit or stand throughout

More information

The Nureva Span ideation system. Installation guide. Single panoramic system

The Nureva Span ideation system. Installation guide. Single panoramic system The Nureva Span ideation system Installation guide Single panoramic system Important SAFETY WARNINGS Prior to the installation of this product, the installation instructions should be completely read and

More information

Horizon ix DL RTC. Page 1 Part No Issue 01 April 12. Description

Horizon ix DL RTC. Page 1 Part No Issue 01 April 12. Description Description This dual lane solution comprises of two dual lane printers configured in series. Each printer has a core cycle time of 4 seconds, with the ability to print boards on one lane, whilst in parallel

More information

1. PRECAUTIONS. Thank you for choosing RUIDE theodolite Disteo 23. Please read this manual carefully before use.

1. PRECAUTIONS. Thank you for choosing RUIDE theodolite Disteo 23. Please read this manual carefully before use. Thank you for choosing RUIDE theodolite Disteo 23. Please read this manual carefully before use. 1. PRECAUTIONS a. Do not collimate the objective lens directly to the sunlight without a filter. b. Do not

More information

Varian, Inc. Vacuum Technologies. The New Unique Varian Dry Turbo Pumping System: TPS-compact

Varian, Inc. Vacuum Technologies. The New Unique Varian Dry Turbo Pumping System: TPS-compact Varian, Inc. Vacuum Technologies The New Unique Varian Dry Turbo Pumping System: TPS-compact NEW DRY TPS-compact The new dry TPS-compact is a portable, fully integrated turbo pumping system powered by

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

Atomic Force Microscope

Atomic Force Microscope Atomic Force Microscope Preparation Before our first appointment to use the microscope, please watch the video tutorials at https://www.afmworkshop.com/atomic-force-microscope-animated-tutorials/. The

More information

JEOL CarryScope SEM Revision /07/17 Page 1 of 7. JEOL CarryScope SEM

JEOL CarryScope SEM Revision /07/17 Page 1 of 7. JEOL CarryScope SEM Page 1 of 7 JEOL CarryScope SEM The JEOL CarryScope is a compact and portable SEM that utilizes a standard tungsten filament. It is to be used for inspecting and measuring samples processed in the NRF

More information

Spectroscopic Ellipsometer --- J. A. Woollam alpha-se

Spectroscopic Ellipsometer --- J. A. Woollam alpha-se Spectroscopic Ellipsometer --- J. A. Woollam alpha-se Introduction Figure 1: J. A. Woollam alpha-se spectroscopic ellipsometer An ellipsometer measures the change in polarization as light reflects or transmits

More information

Exam Microscopic Measurement Techniques 4T th of April, 2008

Exam Microscopic Measurement Techniques 4T th of April, 2008 Exam Microscopic Measurement Techniques 4T300 29 th of April, 2008 Name / Initials: Ident. #: Education: This exam consists of 5 questions. Questions and sub questions will be rewarded with the amount

More information

3000 SERIES LOW PROFILE FLOOR SCALE.

3000 SERIES LOW PROFILE FLOOR SCALE. 3000 SERIES LOW PROFILE FLOOR SCALE www.nascoop.com 3000 SERIES LOW PROFILE FLOOR SCALE An Economical Choice Offering Exceptional Performance The Summit 3000 Series provides exceptional performance in

More information

VBT-75 S2 VACUUM BOTTLE TESTER

VBT-75 S2 VACUUM BOTTLE TESTER VBT-75 S2 VACUUM BOTTLE TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 July 7, 2017 Revision 1 SAFETY

More information

IC Inspection Wafer Loaders NWL860/641. Series

IC Inspection Wafer Loaders NWL860/641. Series NWL860/641 Series The perfect answer to macro insp ection tasks NWL-860 Series The NWL-860 series provides a full range of macro inspection capabilities one of the features considered most essential for

More information

ZLS Corporation. ZLS Dynamic Meter for Marine Applications EXCELLENCE IN GRAVITY METERS. ZLS Dynamic Meter. Applications

ZLS Corporation. ZLS Dynamic Meter for Marine Applications EXCELLENCE IN GRAVITY METERS. ZLS Dynamic Meter. Applications ZLS Corporation EXCELLENCE IN GRAVITY METERS Highest Quality Most Precise Most Rugged Most Reliable Applications Eliminates damper adjustments Eliminates cross-coupling errors Smaller residual imperfection

More information

Beams You Up to a New Era in 3D Water Scanning.

Beams You Up to a New Era in 3D Water Scanning. Beams You Up to a New Era in 3D Water Scanning. On a mission to boldly save time as it was never saved before. BEAMSCAN. The New Water Phantom. Designed to make your work smarter, faster and much easier

More information

Strada Lens Guide. Page 1

Strada Lens Guide. Page 1 Page 1 Contents STRADA lens types... 3 Symmetric... 3 Asymmetric... 4 STRADA-T... 4 STRADA-SQ... 4 STRADA-F... 5 STRADA modules... 6 STRADA 2x2... 6 STRADA 6x1... 7 Mixing STRADA lenses... 8 IESNA type

More information

Agilent 10706B High Stability Plane Mirror Interferometer

Agilent 10706B High Stability Plane Mirror Interferometer 7D Agilent 10706B High Stability Plane Mirror Interferometer Description Description The Agilent 10706B High Stability Plane Mirror Interferometer (see Figure 7D-1) is an improved version of the Agilent

More information

FOX-50 Heat Flow Meter

FOX-50 Heat Flow Meter FOX-50 Heat Flow Meter Site Preparation Guide Revision A Issued June 2016 Page 1 Table of Contents Table of Contents... 1 Ideal Setup... 2 System Components... 3 Instrument Measurements... 4 Utility Requirements...

More information

FC 1800 #1 Operation Manual University of Notre Dame

FC 1800 #1 Operation Manual University of Notre Dame \ FC 1800 #1 Operation Manual University of Notre Dame For Training Please contact: Dave Heemstra 8 June 2015 Page 1 of 12 General Precautions Contacts For problems, clarification of procedures, or general

More information

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 January 2015 Revision

More information

SPECIFICATION FOR BLACK BODY CALIBRATION SOURCE

SPECIFICATION FOR BLACK BODY CALIBRATION SOURCE SPECIFICATION FOR BLACK BODY CALIBRATION SOURCE Source to calibrate Infrared thermometer in the range of 50 C to 1000 C with suitable internal sensor. PID controller and digital display for displaying

More information

AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port

AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port MODEL NUMBER: AVR750U Highlights 750VA ultra-compact 120V line interactive UPS Corrects brownouts and overvoltages from 83V to

More information

QUAD 1000 OWNERS MANUAL OPERATION GUIDE

QUAD 1000 OWNERS MANUAL OPERATION GUIDE QUAD 1000 OWNERS MANUAL OPERATION GUIDE Built in Redmond Oregon USA COMPONENTS 4001-0000 Quad 1000 5 arc second zenith laser featuring electronic servo self-leveling with variable temperature compensation

More information

Three-Dimensional Laser Scanner. Field Evaluation Specifications

Three-Dimensional Laser Scanner. Field Evaluation Specifications Stanford University June 27, 2004 Stanford Linear Accelerator Center P.O. Box 20450 Stanford, California 94309, USA Three-Dimensional Laser Scanner Field Evaluation Specifications Metrology Department

More information

MI-3 Melt Flow Indexer

MI-3 Melt Flow Indexer Göttfert Werkstoff-Prüfmaschinen GmbH Siemensstraße 2 74722 Buchen E-Mail: info@goettfert.de Internet: http://www.goettfert.com W E R K S T O F F - P R Ü F M A S C H I N E N G M B H MI-3 Melt Flow Indexer

More information

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION Document 476092 User and Service Manual Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

6 x 6 Peltier-Thermostatted Multicell Holder Series II Accessory

6 x 6 Peltier-Thermostatted Multicell Holder Series II Accessory 6 x 6 Peltier-Thermostatted Multicell Holder Series II Accessory Overvoltage Category II Pollution Degree 2 Equipment Class III Safety information Introduction Before using this accessory, you must read

More information

Inspiron Series. Views. Specifications

Inspiron Series. Views. Specifications Inspiron 17 5000 Series Views Copyright 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell and the Dell logo are trademarks

More information

ORDERING INFORMATION # of Ports Pressure Type Device Name

ORDERING INFORMATION # of Ports Pressure Type Device Name Freescale Semiconductor Data Sheet: Technical Data High Temperature Accuracy Integrated Silicon Pressure Sensor for Measuring Absolute Pressure, On-Chip Signal Conditioned, Temperature Compensated and

More information

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT Contains Operating and Programming Information Model ATV 4/6 Battery Powered Digital Vacuum Instrument ã 1996, Teledyne Electronic Technologies,

More information