1 Load s Interpact Switch-disconnectors INS/INV0 to 2500 A The Interpact INS/INV switch-disconnectors perform control and disconnection of electrical distribution circuits in the tertiary and industrial sectors: Source coupling Local disconnection box Final distribution box Automation box Emergency stop switch INS/INV Standard version with black handle - Fixed /FC Type Nominal Current (A) INS INS INS INS INS INS INV INV INV INV INV INV60b INV INV INV INV INV Type Nominal Current (A) INS INS INS INS INS INS INS INS Switch-disconnectors with positive contact indication Switch-disconnectors with visible break INS Complete assembly source-changeover systems I II manual sourcechangeover switch with direct front rotary handle

2 28959 Interpact INS0 to INS160 connection accessories Bare cable connectors Snap-on S>95mm² Distribution connector for rigid cables 25mm2 or flexible cables 16mm Terminal shrouds N of poles INS0 to INS80 / / Terminal shields N of poles INS0 to INS80 / / Phase barriers N of poles / 6 Interpact INS0-INS160 electrical auxiliaries Auxiliary contacts 1 OF/CAF/CAO 1 OF/CAF/CAO (low level) Interpact INS0 to INS160 locks,interlocks & coupling accessories Handle locking built-in By 1 to padlocks (OFF position), hasp dia. 5 to 8 mm or by lead seals Interlock for extended rotary handles Mechanical for INS0 to

3 LV2928 LV29252 LV2925 LV2925 Interpact INS0 to INS160 rotary handles Accessories for conversion to extended rotary handles Front control with black handle Lateral control with black handle INS0 to Interpact INS0 to INS160 spare parts Handle for rotary control Front or lateral rotary control black handle INS0 to Interpact INV60 connection accessories (Cu or Al) Rear connections Short (1 pair) Long (1 pair) Short (1 pair) Long (1 pair) LV LV LV275 INV20 to INV LV276 Bare cable connectors LV2922 Steel,snap-on, for cables to 95mm² 160 A LV292 LV Aluminium,snap-on, for cables to 95mm² 250 A LV LV29259 Aluminium,snap-on, for cables to 185mm² 250 A LV29260 Distribution connector for six 1.5 to mm² cables with phase barriers cable, 5mm² to 00mm² INV20 to LV279 LV280 2 cables, 5mm² to 20mm² INV60 LV LV282 Crimp lugs for copper cables (supplied with 2 or phase barriers) cable 120mm² cable 150mm² cable 185mm² (continue to next page)

4 LV2500 LV2502 LV2950 LV250 LV29262 LV285 Interpact INV60 connection accessories (Cu or Al) Crimp lugs for copper cables (supplied with 2 or phase barriers) (continue from previous page) cable 20mm² cable 00mm² INV20 to INV60 Crimp lugs for aluminium cables (supplied with 2 or phase barriers) INV20 to INV60 Terminal extensions (supplied with 2 or phase barriers) cable 150mm² cable 20mm² Right-angle terminal extensions LV2926 Straight terminal extensions LV Right-angle terminal extensions INV20 to Edgewise terminal extensions INV60 LV286 LV287 Spreaders (for upstream or downstream connection) N of poles LV156 Separate for each pole,5mm distance between poles LV Separate for each pole,52.5mm LV distance between poles INV20 to LV Separate for each pole,70mm INV60 LV distance between poles LV29

5 Interpact INV60 connection accessories (Cu or Al) Terminal shields N of poles Short (1 pair) / Long (1 pair) / Short (1 pair) INV20 / Long (1 pair) / 2565 Interpact INV60 electrical auxiliaries Auxiliary contacts (changeover type) OF or CAM (early make or break) 2950 Low-level OF or CAM (early make or INV break) Interpact INV60 rotary handles Extended front handles 1111 for INS250 with standard handle for INS / INV for INS20/00/60 with standard handle 1052 Interpact INV60 Locks,interlocks & coupling accessories Locks built-in By 1 to padlocks (OFF position) INV Locking device for Ronis/Profalux keylocks (without keylocks) Keylock Ronis 151B Keylock Profalux KS5 B2 DZ 2888 Locking device for Ronis/Profalux keylocks (without keylocks) INV20 to Keylock Ronis 151B.500 INV Keylock Profalux KS5 B2 DZ 2888 (continue to next page)

6 115 Interpact INV60 Locks,interlocks & coupling accessories Interlocks (continue from previous page) Mechanical Mechanical INV20 to INV Locking device for Ronis/Profalux keylocks 1115 (without keylocks) INV20 to INV Keylock type (2 keylocks / 1 key) Ronis INV Keylock type (2 keylocks / 1 key) Profalux INV Interpact INV60b to INV1600 connection accessories Vertical connection adapters Vertical connection adaptors - for INV60b Cable lug adapters Cable lug adapters - for INV60b Spreaders Spreaders - for INV60b Base for terminal shield (not compatible with interphase barriers) Base for terminal shield - for 1115 INV60b Terminal shields Terminal shields - for INV60b Interphase barriers (not compatible with terminal shield and base) Interphase barriers - for INV60b..1600

7 Interpact INV60 electrical auxiliaries Auxiliary contacts (changeover type) OF or CAM (early make or break) OF or CAM low level (early make or break) INV60b Interpact INV60 extended front control extended front control INV60b Interpact INV60b to INV1600 locking and interlocking Locking built-in Handle locking by 1 to padlocks (in OFF position) Keylocking device - by keylock (2 pieces) Ronis 151B.500 keylock Profalux KS5 B2 DZ keylock 2888 Interlocking Keylocking device - by keylock (2 pieces) Ronis 151B.500 keylock (1 keylocks / 1 key) Profalux KS5 B2 DZ keylock (1 keylocks / 1 key) Interpact INV60b to INV1600 installation accessories Escutcheon Escutcheon for INV60b /

References. References. Rating (A) Référence

References. References. Rating (A) Référence DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle

More information

Manual source-changeover systems Possible combinations

Manual source-changeover systems Possible combinations Manual source-changeoer systems Possile cominations A manual source-changeoer system can e installed on two or three manually-operated and mechanically interlocked circuit reakers or switch-disconnectors.

More information

NW08 to NW63 fixed circuit breakers Circuit breakers

NW08 to NW63 fixed circuit breakers Circuit breakers fixed circuit breakers Circuit breakers DB404362.eps DB404363.eps A Masterpact fixed circuit breaker is described by 4 catalogue numbers corresponding to: b the basic circuit breaker b a control unit b

More information

Powerpact 4 panelboards Panelboards and incoming devices Panelboards

Powerpact 4 panelboards Panelboards and incoming devices Panelboards Panelboards and incoming devices Panelboards Panelboards MG25C2 250A 13 way powerboard 506.76 MG25C4 250A 17 way powerboard 534.00 MG2C5 250A 5 way panelboard 620.33 MG2C7 250A 7 way panelboard 650.83

More information

the Santon FCS-type switch Disconnect Superior Switch Solutions

the Santon FCS-type switch Disconnect Superior Switch Solutions the Santon FCS-type switch Disconnect Superior Switch Solutions The technical information given in this table applies to 3 and 4 pole fuse combination switches. FRAME SIZE 1 1 2 3 3 4 4a 4b 5 6 6 nominal

More information

References. For SIRCO MV. References

References. For SIRCO MV. References 16 to 160 A Functions Dimensions sircm_071_b_1_x_cat Direct handle M00 handle sircm_041_a_1_x_cat M01 handle Handle colour Handle 16 80 100 125 Blue Blue M00-type M01-type 2299 5012 2299 5032 Handle colour

More information

Communication COM option in Masterpact

Communication COM option in Masterpact CT CCM modbus CD CE Functions and characteristics Communication COM option in 056431 056401 The COM option is required for integration of the circuit breaker or switch-disconnector in a supervision system.

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time

Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time Catalogue G System Pack, wall mount and floor standing enclosures Prisma Plus LV Switchboards Devised to save time General contents Index 2 General presentation 8 Pack 10 17 General presentation Installation

More information

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA for ic60, iid, idpn Vigi, isw-na, RCA and ARA b The electrical auxiliaries are combined with ic60 circuit breakers, iid residual current circuit breakers, remote tripping switch disconnector isw-na, RCA

More information

SIRCO Load break switches for power distribution from 125 to 5000 A

SIRCO Load break switches for power distribution from 125 to 5000 A The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb_cat Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle Direct handle acces_147_a_2_cat

More information

IP68 Sealed - Mini USB Buccaneer

IP68 Sealed - Mini USB Buccaneer IP68 Sealed - IP68 Over moulded assembly provides IP68 cable seal Coupling ring, screw thread provides secure cable coupling Mini USB connector O ring maintains IP68 seal at connector interface Mini USB

More information

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation. Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation

More information

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:

More information

Prisma Plus System P Cubicles up to 4000 A

Prisma Plus System P Cubicles up to 4000 A Low Voltage electric distribution Prisma Plus System P Cubicles up to 4000 A Catalogue 2012 Presentation PD390180_SE.eps IP30/31/55 cubicles b Applications: v indoor cubicles for main or subdistribution

More information

USB Buccaneer BUCCANEER

USB Buccaneer BUCCANEER Over moulded assembly provides IP68 cable seal Coupling ring, screw thread provides secure cable coupling USB adaptor Sealing Cap Clip Standard USB O ring maintains IP68 seal at interface Panel gasket

More information

400 Series - Mini USB Buccaneer

400 Series - Mini USB Buccaneer IP68 Sealed IP68 rated IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof

More information

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu) DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables

More information

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB Motors Automation Energy Transmission & Distribution Coatings DWB Molded Case Circuit Breakers DWB Molded Case Circuit Breakers Molded Case Circuit Breakers DWB Summary Presentation 0 General Characteristics

More information

General Informations 2 Technical data 3 Basic designs 4-8

General Informations 2 Technical data 3 Basic designs 4-8 Contents Page General Informations 2 Technical data 3 Basic designs 4-8 Cam Switches On-Off switches, Changeover switches 9-12 Star-Delta switches 13-15 Multi speed switches 16-20 Control switches 21-23

More information

Source-changeover systems Presentation

Source-changeover systems Presentation Functions and characteristics Source-changeover systems Presentation PB100843 Manual source-changeover system This is the most simple type. t is controlled manually y an operator and consequently the time

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.

More information

Performance. Standards. Technical data

Performance. Standards. Technical data ilos Loadbreak disconnectors for wall mounting ilos H up to ilos up to 5 ilos 4 0 up to Order codes pplications pprovals / Marking ilos H4 ilos H ddon devices Performance Wall mounting Main disconnector,

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

09. DIN CONNECTORS

09. DIN CONNECTORS . 41 612 CONNECTORS Connectors that comply with 41 612 have been in use for years for both board-to-board applications and cable-to-board applications. Their robustness and universality are legendary.

More information

Merlin Gerin LV switch-disconnectors Interpact 40 to 2500A

Merlin Gerin LV switch-disconnectors Interpact 40 to 2500A erlin Gerin LV switch-disconnectors Interpact 40 to 2500A 2 LV switch-disconnectors Interpact from 40 to 2500 A 4 Typical low-voltage applications 6 Compact from 80 to 1250 A 7 asterpact from 800 to 6300

More information

LV power circuit breaker and switch-disconnectors. Masterpact NW Direct current 1000 to 4000 A. Catalogue

LV power circuit breaker and switch-disconnectors. Masterpact NW Direct current 1000 to 4000 A. Catalogue LV power circuit breaker and switch-disconnectors Masterpact NW Direct current 1000 to 4000 A Catalogue 2002 Get more with the world s Power & Control specialist Masterpact NW General contents Presentation

More information

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A. www.moeller.co.uk MCCB Panel Boards 400A / 630A / 800A Product Catalogue and Selection Guide MCCB Panel Boards Moulded Case Circuit Breakers and Accessories XBoard Consumer Units XPole Miniature Circuit

More information

onlinecomponents.com

onlinecomponents.com IP68 Over moulded assembly provides IP68 cable seal IP68 rated USB version 2.0 performance Plug and play capability Visual mating indication Shielded system Single and double ended cables Screw coupling

More information

Standard Buccaneer - USB

Standard Buccaneer - USB IP68 rated IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k USB version 2.0 performance Plug and play capability Visual mating indication Shielded system Single and double ended cables Screw coupling

More information

Application Coding Cable diameter Color Part No. Std. Pack Part No. Std. Pack. Female connector. gray black gray black gray black. turquoise.

Application Coding Cable diameter Color Part No. Std. Pack Part No. Std. Pack. Female connector. gray black gray black gray black. turquoise. .( Connectors Connector for cables of Ø 6 10 and 10 14 mm With screw connection 2) for rigid, of 0.75 m 2. Unassembled with cable gland 1) and locking device. With crimp contacts for of 0.75 m 2. Unassembled

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k or compliant PUR / PVC jacket on cable Shielded system or shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-...

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-... Circuit Breakers, Disconnect Switches, Molded Case Switches 09/064 Moeller Electric Corporation Auxiliary Contacts for. Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

3RT, 3TB, 3TF Contactors for Switching Motors

3RT, 3TB, 3TF Contactors for Switching Motors RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically

More information

GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES. March 2012 PRICE LIST

GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES. March 2012 PRICE LIST GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES March 2012 PRICE LIST Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 380 415 440 460 480 550 600 NEMA-ABI 240 (HIC) 480

More information

Complete UL/CSA Disconnect Switch Kits

Complete UL/CSA Disconnect Switch Kits Product Selection Complete UL/CSA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA handle, auxiliary contacts, and padlock attachment.

More information

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-... Circuit Breakers, 09/054 Moeller Electric Corporation Auxiliary Contacts for Type Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic N.O. N.C. Standard auxiliary

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k or compliant PUR / PVC jacket on cable Shielded system or shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB

More information

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),

More information

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment) 25 Accessories for control enclosures BERNSTEIN attachment Single coupling head (suspended console version) Double coupling head (console version with suspension system attachment) 322.5 231 232 140 The

More information

K1D012ULH cam changeover switch - 2-pole A - screw mounting

K1D012ULH cam changeover switch - 2-pole A - screw mounting Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing

More information

Compact NS 100/400 in the duct Interpact INS 250/400 in the duct Interpact INV 250/400 in the duct

Compact NS 100/400 in the duct Interpact INS 250/400 in the duct Interpact INV 250/400 in the duct push to trip Io Ir.8.9.9.93.7 1.88.95.63.85.98.5.8 1 Ir Im xin xio Ir Im a a.7.63.5.8.9 1 xin Io push to trip Ir.9.93.88.95.85.98.8 1 xio alarm 90 105 alarm 90 105 Im 5 6 4 7 3 8 2 10 xir Im 5 6 4 7 3

More information

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities. KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA

More information

Assembly instructions

Assembly instructions Assembly instructions MKG_ENG_Instructions_H-line_V16_20170731 But also... for choosing Thank you Table of Contents GREY YELLOW PINK GREEN PURPLE DARK GREEN LIGHT BLUE ORANGE BROWN BLUE Identification

More information

ArmorConnect Power and Control Media

ArmorConnect Power and Control Media Selection Guide ArmorConnect Power and Control Media Bulletins 280, 888, 889, 898 2 Bulletin 280, 888, 889, 898 Power Media Product Overview Media Description Features Trunk Cable Cordset - Cable with

More information

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices Siemens AG 201 SENTRON 3LD Main Control and EMERGENCY-STOP Switches Catalog Extract LV 10 Edition 10/201 siemens.com/switching-devices Siemens AG 201 Related catalogs Low-Voltage Power Distribution and

More information

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)9-...

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)9-... Circuit Breakers, 09/074 Moeller Electric Corporation Auxiliary Contacts for Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic device N.O. N.C. Standard auxiliary

More information

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3 Wiring diagrams Content Information for reading and graphic symbols... 5/2 Wiring diagrams of the circuit-breakers... 5/3 Electrical accessories... 5/4 5/1 Information for reading and graphic symbols State

More information

Price List. Low Voltage Distribution Products. With effect from January 18 th, schneider-electric.co.in

Price List. Low Voltage Distribution Products. With effect from January 18 th, schneider-electric.co.in Price List Low Voltage Distribution Products With effect from January 18 th, 2019 schneider-electric.co.in Price List Contents Smart Panels Introduction to Smart Panels...............................

More information

FK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK FK Protection. Trip Unit. Rated Current (A) FK800 FK1250 FK1600

FK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK FK Protection. Trip Unit. Rated Current (A) FK800 FK1250 FK1600 K rame reaking capacities Icu 400/45V in k eff. Type V K K2 K600 N H 80 80 80 L 00 00 Protection Trip Unit K K2 K600 Rated urrent () 60 000 2 600 LTM Mag reak TM SMRe () SMRs () SMRg () LTM Line thermal

More information

Motor protection circuit breakers

Motor protection circuit breakers Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability

More information

Plexo IP 55/IP 66. Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE. For reference only.

Plexo IP 55/IP 66. Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE. For reference only. Plexo IP 55/IP 66 Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE www.legrand.com.sg Plexo IP 55 Ingenious features for easy installation >> Time saving guaranteed: no cut-out Uncut pierceable

More information

IZMX Series Air Circuit Breakers. Small, flexible, efficient

IZMX Series Air Circuit Breakers. Small, flexible, efficient IZMX Series Air Circuit Breakers Small, flexible, efficient Versatile circuit breakers up to 4000 A for cost-effective, optimized solutions. The IZMX16 of the NRX series is the smallest air circuitbreaker

More information

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct

More information

General Specifications

General Specifications Series CW Miniature Power Rockers Touch Tilt Rockers Toggles Slides Rotaries Programmable Illuminated P Pushbuttons Supplement ccessories Indicators Tactiles Keylocks General Specifications CWS CWS CWT

More information

Lady. Stilo. Pendant Station

Lady. Stilo. Pendant Station Direct Lady Stilo MPA Metal Compact Joystick Station Main Power Circuit 1 row 1-3 buttons dust-proof buttons cable entry top side 1 row 2-12 buttons dust-proof buttons cable entry top or bottom side 1

More information

Go to:

Go to: System PKZ 0 ectors 08/019 Clip plate Standard version Short version C-PKZ0 072900 C-PKZ0-K 206740 One of the clip plates is always necessary when combining a PKZM0 manual motor prr and a S(E)00 magnetic

More information

TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters

TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using identical contactors 810373 Contactors with screw clamp

More information

Disconnect Switches. Safe Switching and Disconnecting

Disconnect Switches. Safe Switching and Disconnecting IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as

More information

Assembly Instructions

Assembly Instructions Assembly Instructions MKG_NA-ENG_Instructions_H-line_V16_20170731 But also... for choosing Thank you, Table of Contents GREY YELLOW PINK GREEN PURPLE DARK GREEN LIGHT BLUE ORANGE BLUE Identification of

More information

Air Circuit Breakers. 1/2 Introduction

Air Circuit Breakers. 1/2 Introduction /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers /5 Introduction Up to 6300 A (AC), IEC /6 Introduction /9 General data /6 3-pole, fixed-mounted versions /23 3-pole, withdrawable

More information

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters Type 1 and 2 LV surge s The Type 1 range of surge s meets the normative withstand capability of wave type 10/350 μs (8/20 μs for Type 2 surge s). It is suitable for use with, TN-C and 230 V IT earthing

More information

DETAIL SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET INCH-POUND MIL-DTL-83723/68B 29 June 2009 SUPERSEDING MIL-C-83723/68A (USAF) 17 December 1991 DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, (CIRCULAR, ENVIRONMENT RESISTING), PLUG, THREADED COUPLING,

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

Low voltage distribution products

Low voltage distribution products Price List Low voltage distribution products With effect from December 19, 2014 Price List Contents Smart Panel : Smart Panel concept.... 1 EasyPact EZC: Range Overview.... 3 MCCBs for Distribution Network....

More information

09. DIN Connectors

09. DIN Connectors . Connectors Connectors that comply with have been in use for years for both board-to-board applications and cable-to-board applications. Their robustness and universality are legendary. The classic signal

More information

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) 030 23 030 28 039 21 039 33 039 34 Type 1 voltage surge protectors (V.S.P.) for main

More information

Section Switchgear. > COMMAND Switches > ISOLATORS Series > TOP22 Series

Section Switchgear. > COMMAND Switches > ISOLATORS Series > TOP22 Series Section Switchgear > COMMAND Switches > ISOLATORS Series > 162 16 -disconnectors units > SWITCHING-DISCONNECTORS UNITS > SINGLE JUNCTION BOX Thermal current Ith Power dissipation per pole/contact Type

More information

Siemens AG Air Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Siemens AG Air Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens. Siemens AG Air Circuit Breakers Totally Integrated Power SENTRON Configuration Manual Edition / siemens.com/lowvoltage Siemens AG Siemens AG WL Air Circuit Breakers Introduction WL air circuit breakers/

More information

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A

More information

Section 4. Weatherproof

Section 4. Weatherproof Excel switches 3 XLW770H1 3 XLW770H2 3 XLW770V1 3 XLW770V2 Cat No Excel weatherproof switches, IP56 Plate size 73 x 117mm. Mounting centres: 84mm. to IP56, 10A 1 gang standard size switch for horizontal

More information

07. har-link INTERFACE CONNECTORS

07. har-link INTERFACE CONNECTORS . INTERFACE CONNECTORS The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

Low Voltage. EasyPact MVS. LV power circuit breakers and switch-disconnectors 800 to 4000A. Catalogue 2016

Low Voltage. EasyPact MVS. LV power circuit breakers and switch-disconnectors 800 to 4000A. Catalogue 2016 Low Voltage EasyPact MVS LV power circuit breakers and switch-disconnectors 800 to 4000A Catalogue 2016 EasyPact MVS range The easy choice for reliable performance > Performance without compromise > Assured

More information

Section 20 Distribution (Underground)

Section 20 Distribution (Underground) PREVIOUS SEARCH NEXT Section Distribution (Underground) Table of Contents Page Underground Connectors...-2 Padmount Transformer Connectors...-3 Pedestal Connectors...-4 Pedestal Block Connector...-6 Street

More information

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A

FUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A Fuse protection The solution for > Motor load break. > Protection of industrial cabinet. > Electrical distribution. ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches

More information

Large Frame IEC Contactors

Large Frame IEC Contactors Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1 Changing Applications for Contactors There are fewer and fewer traditional large motor starting

More information

General Specifications

General Specifications Series M00 Tipped Rockers & Paddles Touch Tilt Rockers Toggles Slides Rotaries Programmable Illuminated P Pushbuttons Supplement Accessories Indicators Tactiles Keylocks General Specifications Electrical

More information

ODU DOCK and ODU ROB. Connectors for Docking and Robot Systems.

ODU DOCK and ODU ROB. Connectors for Docking and Robot Systems. and ODU ROB Connectors for Docking and Robot Systems Robust Circular Connectors and ROB Applications Industrial robots Tool change and depot systems Cable connections for robot systems Test equipment Features

More information

Contents Rockers. A Series... B4 Process Sealed 0.4VA Logic Level Straight, Right Angle, & Vertical PC

Contents Rockers. A Series... B4 Process Sealed 0.4VA Logic Level Straight, Right Angle, & Vertical PC Contents Rockers Toggles Rockers Supplement Accessories Indicators Touch Tilt Tactiles Slides Rotaries Keylocks Programmable Illuminated P Pushbuttons A Series... 4 Process Sealed 0.4VA Logic Level Straight,

More information

Pan assemblies and installation accessories

Pan assemblies and installation accessories Contents Section 10 Pan assemblies and installation accessories SP&N pan assemblies 124 SP&N door and cover 124 TP&N pan assemblies 125 TP&N door and cover 125 Multiclip busbar and Polybloc 126 Comb busbars

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: This is to certify that representative samples of SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY MOTOR CONTROLLERS, MANUAL (See following page for additional information.)

More information

Modular switch disconnectors and modular change-over switches

Modular switch disconnectors and modular change-over switches Modular switch disconnectors and modular change-over switches Modular switch disconnectors and modular change-over switches The new generation of modular switch disconnectors is guarantee of reliability

More information

IT power distribution Power distribution units (PDU) Basic. Versions available:

IT power distribution Power distribution units (PDU) Basic. Versions available: IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,

More information

ENERGY SAFELY SWITCHED SWITCHGEAR. BUSBAR SYSTEM 60 mm

ENERGY SAFELY SWITCHED SWITCHGEAR. BUSBAR SYSTEM 60 mm ENERGY SAFELY SWITCHED SWITCHGEAR BUSBAR SYSTEM 60 mm SWITCHGEAR ENERGY safely switched About Grupa Apator Who we are? Grupa Apator is a dynamic Polish capital group, it currently includes 14 companies

More information

SENTRON 3VL Molded Case Circuit Breakers

SENTRON 3VL Molded Case Circuit Breakers Siemens AG SENTRON VL Molded Case Circuit Breakers Switching, Protection, Measuring and Monitoring Devices For the operating range from A to 00 A, the molded case circuit breaker ensures the optimum overload

More information

Dorman Smith Loadbank 125 MCCB Panel Boards

Dorman Smith Loadbank 125 MCCB Panel Boards Dorman Smith Loadbank 125 MCCB Panel Boards Section 3 MCCB Panel Boards Loadbank 125 Range (250A and 400A Ratings) Overview Key Features ASTA certified busbars with a short circuit rating of 25kA for 1

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics Full face, bright LED illumination in choice of red, green, and amber for visible status indication. 9-amp or 6-amp electrical capacity in compact body. Interior shield prevents

More information

Description. Installation. Power supply

Description. Installation. Power supply Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of

More information

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

POWERTEC 305S, 365S, 425S & 505S

POWERTEC 305S, 365S, 425S & 505S POWERTEC 305S, 365S, 425S & 505S IM3023 11/2009 Rev. 0 Spare Parts... 1 POWERTEC 305S, 365S, 425S & 505S... 1 Figure A: Machine Assembly 1-305S... 2 Figure B: Machine Assembly 2-305S... 3 Figure C: Machine

More information

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka) MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and

More information

Specifications. S&C Line-Rupters. For Line and Cable Switching. Outdoor Transmission (115 kv through 230 kv) Conditions of Sale

Specifications. S&C Line-Rupters. For Line and Cable Switching. Outdoor Transmission (115 kv through 230 kv) Conditions of Sale Outdoor Transmission ( kv through 230 kv) For Line and Cable Switching Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified

More information

3RV1 Circuit-Breakers

3RV1 Circuit-Breakers SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a

More information