9U MTCA.4 Shelf JTAG/White Rabbit Support
|
|
- Adelia Eleanor Quinn
- 6 years ago
- Views:
Transcription
1 9U MTCA.4 Shelf JTAG/White Rabbit Support Description Schroff Product Number: U MicroTCA.4 Shelf 12 Slots with White Rabbit Support U MicroTCA.4 Shelf 12 Slots without White Rabbit Support R. Waldt/FAE/ Blatt 1 / 7
2 Product Definition The both versions of the Schroff 9 U MicroTCA.4 Shelf with rear μrtm area are prepared for AMC double mid-size modules and RTMs double mid-size. Each shelf provides the option to assemble a JTAG-module on the lower rear side. Shelf pn : - Prepared to support the White Rabbit protocol. - No update-channel between the MCHs. Shelf pn : - No support the White Rabbit protocol. - Update-channel between the MCHs. Hardware Platform Shielded galvanized steel subrack with 19 rack mounting brackets MicroTCA Backplane with radial IPMI-L from both MCH slots to all AMC slots and bused IPMB-0 among MCHs, PMs and CUs. The backplane supports the White Rabbit protocol. The Shelf provides: 12 AMC double mid-size slots 2 redundant MicroTCA Carrier Hub (MCH) slots (double full-size) 4 Power Module (PM) slots (double full-size) 12 RTM double mid-size slots 1 JSM slot single full size in a separate card cage on the lower area of the rear side. Active cooling through two hot-swappable Cooling Units (CUs) in push-pull configuration, providing each: 6 speed controlled 12 VDC fans. Cooling Unit Enhanced Module Management Controller (CU EMMC) Display Module Front accessible air filter Backplane The slot MicroTCA Backplane provides: 12 AMC double Mid-size slots (4 HP) 2 double Full-size MicroTCA Hub (MCH) slots (6 HP) 4 Power Module (PM) slots for Double Full-size Power Modules or for 2 x 12 HP Power Modules 1 AMC connector for JTAG-module S-FS 2 Connectors for Cooling Units Depending of the shelf version the backplane supports the White Rabbit trigger distribution or the MCH update channel by the assembly positions of 0 Ω resistors. The mapping of MCH-ports to AMC-ports is not critical since all ports on MCH timing modules are fully programmable. But this needs to be defined. R. Waldt/FAE/ Blatt 2 / 7
3 Backplane Topology R. Waldt/FAE/ Blatt 3 / 7
4 Backplane for shelf pn with support of the White Rabbit trigger distribution. The Update-Channels between the MCHs are disconnected and the White Rabbit-Clock-connections to the AM1/AMC12 are realized with 0 Ω resistors. Backplane for shelf pn with update-channel between the MCHs. The Update-Channels between the MCHs are connected via 0 Ω resistors and the resistors for the White Rabbit-Clock-connections to the AM1/AMC12 are not assembled. Backplane rear side Detailed view Assembly option for Update-Channel Assembly 0 Ω-resistors for WR-Support Assembly option for Update-Channel R. Waldt/FAE/ Blatt 4 / 7
5 JTAG-module The chassis provides an assembly room for a JTAG-module single full-size in the lower area of the rear side. This position avoids any occupation of an AMC slot and due to the low heat dissipation the air flow is sufficient. The module itself is not part of the delivery volume. R. Waldt/FAE/ Blatt 5 / 7
6 JSM Slot Pinout Air Filter The MicroTCA Shelf provides a front replaceable air filter. The filter meets the following standards and classifications: UL 900 Class 2, UL94 HF-1 Telcordia NEBS GR-78-CORE Telcordia NEBS GR-63-CORE R. Waldt/FAE/ Blatt 6 / 7
7 Cooling Units The MicroTCA Shelf provides two front-pluggable Cooling Units. Each Cooling Unit contains three 12 VDC fans (290m³/h (171 cfm) each) for the AMC section, three 12 VDC fans (190 m³/h (111 cfm) each) for the μrtm section and a Schroff Cooling Unit Enhanced Module Management Controller (CU EMMC). The speed level of the AMC and the μrtm fans can be controlled independently. The CU EMMC has an Enhanced Module Management Controller (EMMC) onboard that communicate with the Carrier Manager over IPMB-0. The CU EMMC controls the fan speed, monitors the air filter sensor and provides hot-swap functionality. 1-6 Fan 7 Hot swap bush button 8 CU 1 9 CU 2 Technical Data R. Waldt/FAE/ Blatt 7 / 7
MTCA.4 TUTORIAL BASICS INTRODUCTION IN XTCA
MTCA.4 TUTORIAL BASICS INTRODUCTION IN XTCA TWEPP 2016 SEPTEMBER 26, 2016 KIT, KARLSRUHE Rüdiger Cölln Pentair Technical Solutions GmbH ruediger.coelln@pentair.com AGENDA What is xtca? Specifications Overview
More information1U MTCA Shelf. User s Manual. Product Number: /025
1U MTCA Shelf User s Manual Product Number: 11850-024/025 Doc-No: 63972-325_D1.0 November 12, 2013 D1.0 November 12, 2013 Draft Release Impressum: Schroff GmbH Langenalber Str. 96-100 75334 Straubenhardt,
More informationfor Special Applications
Lower Cost MicroTCA for Special Applications MICROTCA IS AN EXTREMELY VERSATILE TECHNOLOGY WITH MANY APPLICATIONS DRIVING MANY DIFFERENT REQUIREMENTS. SYSTEM DESIGNERS CAN REDUCE COSTS BY CONSIDERING WHAT
More informationWhite Paper. About MicroTCA.4: An High-Performance Architecture with I/O and Signal Conditioning Provisions
White Paper About MicroTCA.4: An High-Performance Architecture with I/O and Signal Conditioning Provisions MicroTCA is a powerful, compact open-standard COTS architecture used in Military, Aerospace, Communications/
More information2U µtca Chassis with 12 AMC slots VT881
VT TM THE POWER OF VISION KEY FEATURES µtca System Platform x U x deep Full redundancy with dual MicroTCA Carrier Hub (MCH), dual Cooling Units and dual Power Modules Up to twelve s: four full-size and
More informationVT816 1U µtca.4 Chassis with 2 AMC Slots, PCIe Gen 3
1U µtca.4 Chassis, 2 AMCs KEY FEATURES MicroTCA.4 low-profile chassis platform, 19 x 1U x 14.2 deep Integrated Intel Xeon E3-1125 v2 processor @2.5 GHz Compliant to µtca.4 specifications with rear IO Supports
More informationYour Solution Partner
Your Solution Partner 1 Short Presentation Elma & Elincom Elma Electronic is a global manufacturer of products for housing electronic systems. The company provides everything from components such as modular
More informationµtca Conduction Cooled Chassis with 8 AMC slots
VT0 TM THE POWER OF VISION KEY FEATURES µtca System Platform / Air Transport Rack (ATR) Short Tall, with NO internal fan (with handle deep) Customized Front Panel Input and Output Connectors per MIL-M999
More information1U µtca Chassis, 10 AMCs, 10GbE, 1100W VT848
1U µtca Chassis, 10 s, 10GbE, 1100W VT848 1U µtca Chassis, 10 s KEY FEATURES 1U chassis platform Ten mid-size slots Integrated MCH.2 and.3 compliant 10GbE/1GbE Fabric 10GbE on ports 4-7 and 8-11 GbE on
More informationVT992 1U External Power Supply for MTCA Systems, Quad 1200 W
KEY FEATURES 1U External Power Up to four hot-swappable Power Units per PSU Four 48V DC Output via front panel MicroTCA 1U 19 rack mount chassis platform RoHS compliant Benefits of Choosing VadaTech 1U
More informationvme, vme64x, vxs, vpx
vme, vme4x, vxs, vpx VME, VME4x, VXS, VPXMain Catalogue Systems VME, VME4x, VXS, VPX OVERVIEW MAIN KATALOG Cabinets....... 1 Wall mounted cases.......... 2 for cabinets and wall mounted cases.. 3 Climate
More informationNATIVE-STARTER (Plus) Users Manual. NATIVE-STARTER NATIVE-STARTER-PLUS Users Manual Version 0.4
NATIVE-STARTER NATIVE-STARTER-PLUS Users Manual Version 0.4 NATIVE-STARTER and NATIVE-STARTER-PLUS have been designed by: N.A.T. GmbH Kamillenweg 22 D-53757 Sankt Augustin Phone: ++49/2241/3989-0 Fax:
More information5U µtca Chassis, 12 AMC, 40GbE VT866
5U µtca Chassis, 12 AMCs KEY FEATURES μtca System Platform 19 x 5U x 10.5 deep (with handles 12 deep) Full redundancy with dual MicroTCA Carrier Hub (MCH), dual Cooling Units and dual Power Modules Up
More information1 VT814 2U µtca.4 Chassis with 6 AMC Slots
VT814 U µtca.4 Chassis with 6 Slots Key Features MicroTCA rack mount or deskp chassis platform, 19 x U x 14. deep VT814 Compliant µtca.4 specifications with rear IO for High-Energy Physics and other applications
More information3+1 U CPCI Serial System
3+ U CPCI Serial System User s Manual Product Number: 4579-46/47/48/49/40/4/4/43/44 Doc-No: 6397-349_R.0 January 06 R.0 January 06 Initial Release Impressum: Schroff GmbH Langenalber Str. 96-00 75334 Straubenhardt,
More informationNew standards for high speed networks
Packaging Solutions New standards for high speed networks AdvancedTCA System assembled with AdvancedMC Carrier and Modules AdvancedMC Modules inside a Carrier µtca System assembled with AdvancedTCA Modules
More informationVT857 1U µtca Chassis, 12 AMC, 10 GbE
1U µtca Chassis, 12 s KEY FEATURES Twelve mid-size single module slots or six midsize double module slots Cascade any number of 1U Carriers for expansion and management Management can run as Shelf/MCMC
More informationIntroduction to MicroTCA
Introduction to MicroTCA Ray Larsen SLAC MicroTCA Review 1 Outline I. MicroTCA for Physics Basics II. Physics System Requirements III. COTS & Lab Developments IV. xtca Market Growth Projections V. Summary
More informationCooling System. Cooling System Overview. 16-Slot Line Card Chassis Airflow
This chapter describes the components that make up the cooling system of the Cisco CRS Series Carrier Routing System 16-Slot Line Card Chassis. It contains the following sections: 16-Slot Line Card Chassis
More information19 Rackmount Cases A3211. Enrich Your Product Line and Build Your Brand Awareness
19 Rackmount Cases A3211 Enrich Your Product Line and Build Your Brand Awareness 0303-00283 USER S MANUAL Table of Contents 1. Introduction. 1 2. Standard parts. 2 2-1 Disassembly of the Top Cover...2
More informationUTC040C MicroTCA Carrier Hub (MCH) Conduction Cooled, PCIe Gen3
KEY FEATURES µtca.3 MCH, PCIe Gen 3 Double module, mid-size per AMC.0 Conduction cooled for rugged applications Unified 1GHz quad-core CPU for MCMC (MicroTCA Carrier Management Controller), Shelf Manager,
More informationMicroTCA Power Module
MicroTCA Power Module 92-000025-000 Preliminary Release Rev.52 Copyright 2003-2006, CorEdge Networks. All rights reserved. CorEdge Networks, 50 Commonwealth Ave. Suite 504, Boston, MA 02116 USA THIS DOCUMENT
More informationWhenever your system needs to communicate COMMUNICATE WITH N.A.T. FMC. backplane-viewer. SRIO Gen 2 SFP+ test. redundancy ADSP-8/16.
www.nateurope.com - innovation in communication Whenever your system needs to communicate COMMUNICATE WITH N.A.T. MicroTCA research JTAG FPGA deep packet inspection ARRIA10 MPC8569 extender NATIVE-Starter
More informationPS-1142 MicroTCA 1000W Power Module
PS-1142 MicroTCA 1000W Power Module PICMG MTCA.4 Standard Wide range AC/DC 16X12Vdc/7.6A 16x3.3Vdc/0.2A Power Module (PM) Description The PS 1142 power module designed for use in µtca system compliant
More informationPixus Technologies Catalog
The Power of Embedded Ingenuity Pixus Technologies Catalog Kaparel, Ripac, & Vario Brand Products www.pixustechnologies.com sales@pixustechnologies.com US: 916.524.8242 CAN: 519.885.5775 Order Information
More information2 Slot AdvancedTCA Chassis User Manual
2 Slot AdvancedTCA Chassis User Manual TABLE of CONTENTS DESCRIPTION PAGE TITLE PAGE 1 TABLE of CONTENTS 2 1.0 General Information 5 1.1 Introduction 5 1.2 References 5 1.3 Company Overview 5 1.4 Features
More informationLow cost 1U µtca Chassis with 2 AMC slots and integrated option for Dual 2.5 SATA/SAS Disk
VT855 TM THE POWER OF VISION KEY FEATURES Two mid-height slots or two double width mid-height in 1U Chassis Management can run as Shelf/MCMC (MicroTCA Carrier Management Controller) or MCMC.1,.2,.3,.4
More informationMicroTCA / AMC Solutions for Real-Time Data Acquisition
THE MAGAZINE OF RECORD FOR THE EMBEDDED COMPUTING INDUSTRY May 2013 TECHNOLOGY IN SYSTEMS MicroTCA / AMC Solutions for Real-Time Data Acquisition MicroTCA has evolved out of the world of ATCA to become
More informationelectronics Protection
advancedtca electronics PROTECTION 07/2017 PRODUcT catalog WWW.SCHroFF.PENTAIR.co.uk AdvancedTCAMain Catalogue Content Systems AdvancedTCA Cabinets...... 1 Wall mounted cases......... 2 Accessories for
More information1 Airflow via normal convection or forced-air cooling devices in the enclosure or housing outside of the subrack.
T Accessories n Subrack Cooling n Vertical Cooling From Bottom To Top D 1 Airflow via normal convection or forced-air cooling devices in the enclosure or housing outside of the subrack. 2 Vertical forced
More informationComponents of a MicroTCA System
Micro TCA Overview0 Platform, chassis, backplane, and shelf manager specification, being developed through PICMG Allows AMC modules to plug directly into a backplane Fills the performance/cost gap between
More informationVPX6VR180. OpenVPX 6U Chassis Platform, RiCool Blowers VPX6VR180 KEY FEATURES
VPX6VR180 VPX6VR180 KEY FEATURES 6U vertical-mount chassis platform for 3U Open- VPX cards Supports RTMs for rear I/O Up to 18 slots OpenVPX slots (3U) at 0.8 pitch, 16 slots at 1.0 pitch, 1.0 pitch is
More informationVPX9VR180. OpenVPX 9U Chassis Platform, RiCool Blowers VPX9VR180 KEY FEATURES. 6U version shown (for 3U cards) illustrating removable fans
VPX9VR180 6U version shown (for 3U cards) illustrating removable fans VPX9VR180 KEY FEATURES 9U vertical-mount chassis platform for 6U OpenVPX cards or dual segments of 3U Open- VPX cards Supports RTMs
More informationCPCI PSB System Subrack 10 U
CPCI PSB System Subrack 10 U User Manual Product Number: Doc-No: 63972-163 Revision: R1.0, November 21, 2007 Rev. Date updated Change R1.0 November 21, 2007 Initial release Impressum: Schroff GmbH D-75334
More information6U µtca Desktop Chassis, 6 AMC Full Size, 40GbE VT898
6U µtca Chassis, 6 AMCs KEY FEATURES μtca Desktop (rackmount optional) System Platform 10 x 6U x 10.5 deep Redundant cooling in push/pull front-to-rear airflow configuration Spring-loaded carry handle
More informationPromentum MPCBL0050 PRODUCT BENEFITS. Dual-Core Intel Xeon Processor LV Dual Core Xeon processor module FEATURE SUMMARY. [Print This Datasheet]
[Print This Datasheet] Promentum MPCBL0050 Dual Core Xeon processor module FEATURE SUMMARY High performance AdvancedTCA blade based on the Dual-Core Intel Xeon LV5138 processor that provides 4 processor
More informationAMC759. Key Features. Benefits. Intel Xeon E3 Processor AMC, SRIO Gen2 AMC759. Processor AMC Intel Xeon Processor E3-1505M v6 (Kaby Lake)
Key Features Intel Xeon E3 Processor AMC, SRIO Gen2 Processor AMC Intel Xeon Processor E3-1505M v6 (Kaby Lake) SRIO Gen2 on ports 4-7 and 8-11 (AMC.4) Serial Over LAN (SOL) 16 GB of DDR4 memory with ECC
More informationOPTIONS FOR NEXT GENERATION DIGITAL ACQUISITION SYSTEMS
OPTIONS FOR NEXT GENERATION DIGITAL ACQUISITION SYSTEMS A. Boccardi, CERN, Geneva, Switzerland Abstract Digital acquisition system designers have an always increasing number of options in terms of bus
More informationVT873 µtca Conduction Cooled Chassis ½ ATR with 6 AMCs
VT87 µtca Conduction Cooled Chassis ½ ATR with 6 s KEY FEATURES µtca ½ ATR, 6 s μtca. Conduction Cooled System Platform 1/ Short Air Transport Rack (ATR) Per ARNIC404A, with NO internal fan (1.6 deep without
More informationCOMPUTING AXP G AdvancedTCA Shelf. This six-slot, 40G ATCA shelf is ideal for both traditional telecom and enterprise environments.
COMPUTING Data Sheet This six-slot, 40G ATCA shelf is ideal for both traditional telecom and enterprise environments 6-slot, 7U, 19 form factor AC & DC power input options All redundant field replaceable
More informationACQ400-MTCA-RTM-2 Functional Specification. High Performance Simultaneous Data Acquisition
ACQ400-MTCA-RTM-2 Functional Specification High Performance Simultaneous Data Acquisition Rev 6 Page 1 of 24 Date: 14 January 2016 Document Revisions Rev Date Notes Author 1 11 Mar, 2015 Initial Release
More information3U ATCA Hybrid Chassis with 8 AMCs (Mid-size) VT835
3U ATCA Hybrid Chassis (Representative model only exact configuration will change) KEY FEATURES 19 rack mount 3U ATCA Hybrid AMC Chassis Holds 1 ATCA slot and 8 mid-size AMC slots 40G or 10G fabric across
More informationVol. S Cost Effective Customization Capabilities Wide Breadth of Products.
Vol. S4-3-4 Cost Effective Customization Capabilities Wide Breadth of Products All products and company names listed are trademarks or trade names of their respective companies. All specifications are
More informationVME64x System Subrack 8 U
User s Manual Product No.: Doc-No: 63972-158 Revision: R1.1, November 14, 2008 Rev. Date updated Change R1.0 November 19, 2007 Initial release R1.1 November 14, 2008 Part no. FCM added Impressum: Schroff
More informationPower Supply Installation
Power Supply Module Overview, on page Installation Guidelines, on page 4 Installing or Replacing an AC Power Supply, on page 6 Installing a DC Power Supply, on page 7 Finding the Power Supply Module Serial
More informationAXIe-1: Base Architecture Specification. Revision 2.0
AXIe-1: Base Architecture Specification Revision 2.0 September 5. 2013 Important Information AXIe-1 Base Architecture Specification is authored by the AXIe Consortium companies. For a vendor membership
More informationCPCI System Subrack 3 U
User s Manual Product No.: Doc-No: 63972-224_R1.1 April 18, 2011 Rev. Date updated Change R1.0 January 14, 2008 Initial Release R1.1 April 18, 2011 Fan Tray with mini compression latch Impressum: Schroff
More informationAXIe-1: Base Architecture Specification. Revision 3.1
AXIe-1: Base Architecture Specification Revision 3.1 January 11, 2018 Important Information AXIe-1 Base Architecture Specification is authored by the AXIe Consortium companies. For a vendor membership
More informationVT951 1U Rugged Chassis Platform, 6 AMC Slots, PCIe Gen 3, Dual PSU
1U Rugged Chassis, 6 s KEY FEATURES MicroTCA rugged 1U 19 rackmount chassis platform Designed to meet MIL-STD-810F, MIL-STD-901D for shock/vibration Designed to meet MIL-STD-461E for EMI Supports up to
More informationCPCI System Subrack 1 U
User s Manual Product No.: Doc-No: 63972-165_R1.0 January 14, 2008 Rev. Date updated Change R1.0 January 14, 2008 Initial Release Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in this
More informationOracle <Insert Picture Here>
Slide 1 Oracle Slide 2 WZT-6509 version B Sun Fire Nehalem and Westmere Rack-Mount Server Installation and Replacement Welcome to the installation and replacement
More informationCPCI System Subrack 3 U
User s Manual Product No.: Doc-No: 63972-227_R1.1 April 18, 2011 Rev. Date updated Change R1.0 January 14, 2008 Initial Release R1.1 April 18, 2011 Fan Tray with mini compression latch Impressum: Schroff
More informationRMC HS. User Manual. Version 1.0
RMC2108-670-HS User Manual Version 1.0 Content Manual Structure Foreword Chapter 1 Chassis Overview Chapter 2 Easy Installation Instruction Chapter 3 Chassis Parameters Foreword This manual is about the
More informationCisco ONS CL Shelf Assembly Hardware
CHAPTER 1 This chapter provides a description of Cisco ONS 15310-CL shelf hardware. Instructions for installing equipment are provided in the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.
More informationSerial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E
Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:
More informationVME Subrack System 7 U
User Manual Product Numbers: 20836-715 20836-718 Doc-No: 63972-148 Revision: R1.1, November 14, 2008 Rev. Date updated Change R1.0 August 22, 2006 Initial Release R1.1 November 14, 2008 Part no. FCM added
More informationGeneral Purpose Chassis for PXI and CompactPCI
General Purpose PXI-1000B, PXI-1002, PXI-1006 Accepts both 3U PXI and 3U CompactPCI modules Filtered, forced-air cooling Integrated, internal power supplies Complies with PXI and CompactPCI specifications
More informationChassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components.
This chapter provides an overview of the Cisco NCS 4016 chassis and components. About the Cisco NCS 4016 Chassis, page 1 Chassis Components, page 6 Chassis Cable Management, page 11 Safety Guidelines,
More informationVME System Subracks 7 U / 8 U
User Manual Product Numbers: 20836-716 20836-719 20836-815 Doc-No: 63972-147 Revision: R1.0, September 22, 2006 Rev. Date updated Change R1.0 September 22, 2006 Initial Release Impressum: Schroff GmbH
More information2: Front Panels for Plug-In Units
C 2: Front Panels for Plug-In Units 2.1 Plug-In Units acc. to IEC C 2_3 2.1.1 Extruded Front Panel C 2_3 2.1.2 Front Panel with Cutout for IEC Ejector Handle C 2_5 2.2 EMC Plug-In Units acc. to IEC C 2_6
More informationUser's Manual CPCI Basic 3U, 30HP CPCI Basic 3,5U, 42HP
User's Manual CPCI Basic 3U, 30HP CPCI Basic 3,5U, 42HP www.hartmann-elektronik.de Rev. 1.2 Rev: R 1.0 26.05.2010 Borutta R 1.1 12.08.2010 Friedrich R 1.2 09.08.2011 F. Minich Impressum: Hartmann Elektronik
More informationCPCI/CPCI Serial Hybrid System 3+1 U
(PICMG 2.30, CPCIS.0) User s Manual Product No.: Doc-No: 63972-262_R1.0 January 04, 2010 Rev. Date updated Change D1.0 February 16, 2009 Draft Release R1.0 January 04, 2010 Initial Release Impressum: Schroff
More information1U Chassis with 6 AMCs, Quad SPF+, Redundant Power VT840
1U Chassis, Redundant Power KEY FEATURES Six mid-height AMC slots per 1U carrier or two doublewidth, mid-height plus two mid-height AMC slots Management can run as Shelf Manager or MCMC (MicroTCA Management
More informationAn Integrator s Guide to MicroTCA Part II How a FRU starts up
An Integrator s Guide to MicroTCA Part II How a FRU starts up By Thomas Kastner, Advantech In the previous article of this series we covered the basic system management aspects and architecture of MicroTCA.
More informationTELCO. Tomi Männikkö/HW Architect, Datacenter R&D/ Nokia
TELCO EDGE SERVER AND CHASSIS Tomi Männikkö/HW Architect, Datacenter R&D/ Nokia Open edge chassis overview Key specifications 3U, 19 mountable (EIA-310 compatible) 130.6 x 440 x 430 mm (H x W x D) 1U and
More informationThe Advantages of AdvancedTCA * The Telecom Industry s Open Standard for Equipment Manufacturers
The Advantages of AdvancedTCA * The Telecom Industry s Open Standard for Equipment Manufacturers Intel in Communications The Advantages of AdvancedTCA* Contents Executive Summary 2 Trends Driving AdvancedTCA*
More informationATCA-7301 AdvancedTCA Processor Blade
ATCA-7301 AdvancedTCA Processor Blade The ATCA-7301 is a high performance ATCA processor blade for data and control plane applications n 2.16 GHz Intel Core 2 Duo 64-bit processor n On-board Gigabit Ethernet
More informationVME64x System Subrack 1 U
User s Manual Product No.: Doc-No: 63972-157_R1.0 November 09, 2007 Rev. Date updated Change R1.0 November 09, 2007 Initial Release Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in
More informationComplete ATCA IPMI Test Suite and Validation or VT027/VT028 Development. FIGURE 1: ATC001 option load for IPMI Test Suite and Validation
ATC001 TM THE POWER OF VISION FIGURE 1: ATC001 option load for IPMI Test Suite and Validation KEY FEATURES Capture and store I 2 C bus data Analyzer mode Exerciser mode Compliance test mode Graphical User
More informationDMC-1000 Chassis-Based Media Converter
DMC-1000 Chassis-Based Media Converter User s Guide Rev. 01 (Jan. 2002) 6012-9600131 (1907MCR11616000) Printed In Taiwan RECYCLABLE i TABLE OF CONTENTS TABLE OF CONTENTS... II PREFACE... 3 19 MEDIA CONVERTER
More informationAMC524 / AMC524C Quad ADC, 125 MSPS, Dual DAC, Artix-7
KEY FEATURES KEY FEATURES Quad ADC, Dual DAC, Artix-7 Photo Coming Soon Quad ADC 16-bit @ 125 MSPS (AD9653) Dual DAC 12-bit @ 2.5 GSPS () Artix-7 FPGA with dual banks of DDR-3, 2 GB total Conduction cooled
More informationMicroTCA for Medical Applications
1 / 7 MicroTCA for Medical Applications By Claudia Bestler, Dr. Stephan Rupp, Kontron W ithin the shortest period of time, a huge choice of Advanced Mezzanine Cards has become available on the market.
More informationFront-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs.
, on page 1 External Features, on page 2 Serviceable Component Locations, on page 6 Summary of Server Features, on page 9 The server is orderable in different versions, each with a different front panel/drive-backplane
More informationCisco CRS-1 Carrier Routing System
CHAPTER This site planning guide describes how to plan and prepare your site facilities for the installation of a 8-Slot Line Card Chassis (also referred to in this document as the Cisco CRS- 8-slot line
More informationUser's Manual CPCI Basic 3U and 6U, 84HP VPX Basic 4U, 84HP Fan Tray 1U, 84HP
User's Manual CPCI Basic 3U and 6U, 84HP VPX Basic 4U, 84HP Fan Tray 1U, 84HP www.hartmann-elektronik.de Rev. 1.0 Rev: R 1.0 26.05.2010 Borutta Impressum: Hartmann Elektronik GmbH Motorstraße 43, D-70499
More informationContinuon Beyond High Availability NEBS Blade Server. White Paper. On the Innovations in the Continuon Product Family by I-Bus
Continuon Beyond High Availability NEBS Blade Server White Paper On the Innovations in the Continuon Product Family by I-Bus February 28, 2003 Johni Chan I-Bus Corporation 2391 Zanker Road, #380 San Jose,
More informationMicroTCA Carrier Hub (MCH), Double Module, PCIe Gen 3 Expansion UTC006
MCH, PCIe Gen 3 Expansion Photo Coming Soon KEY FEATURES Double module, full size per AMC.0 and MTCA.4 Quad ports for PCIe Gen 3 expansion (x4, x8, or x16) Unified 1GHz quad-core CPU for MCMC (MicroTCA
More informationVTX660. Key Features. Benefits. 8U VPX Chassis, Six 3U Slots with RTM Support VTX660
v VTX660 Key Features 8U Chassis, Six 3U Slots with RTM Support 8U Open rackmount system platform Dedicated Switch/management slot Up to five 3U payload slots Compatible with 0.8-inch, 0.85-inch and.0-inch
More informationelectronics Protection
accessories electronics PROTECTION 07/2017 PRODUcT catalog WWW.SCHROFF.PENTAIR.co.uk Fan control module (FCM2) AccessoriesMAIN CATALOGPart number in bold face type: ready for shipping within 2 working
More informationPrisma II Platform. Optoelectronics
Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the
More informationType 12. VITA-Based System Platforms. VME, VME64x, VPX, VXS, VXI, and more. Backplanes. Elma Electronic
Type 12 Backplanes ACcessories SYSTEM COMPONENTS INTEGRATION SERVICES VITA-Based System Platforms VME, VME64x, VPX, VXS, VXI, and more TEST & VALIDATION SERVICES Elma Electronic www.elma.com Elma Electronic
More informationStatus of MTCA Infrastructure
Status of MTCA Infrastructure June 4-5, 2012 Chengcheng Xu for infrastructure team: Sonya Hoobler, Kukhee Kim, Till Straumann, Ernest Williams, Jingchen Zhou Outline Infrastructure Hardware Evaluation
More informationSignal Conversion in a Modular Open Standard Form Factor. CASPER Workshop August 2017 Saeed Karamooz, VadaTech
Signal Conversion in a Modular Open Standard Form Factor CASPER Workshop August 2017 Saeed Karamooz, VadaTech At VadaTech we are technology leaders First-to-market silicon Continuous innovation Open systems
More informationFVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL
2-CHANNEL 10-BIT DIGITALLY ENCODED VIDEO + 2 BI-DIRECTIONAL DATA + AIPHONE INTERCOM + 4 CONTACT CLOSURE + 100MB ETHERNET + REDUNDANT POINT-TO-POINT DUAL SFP OPTICAL PORTS The series utilize 10-bit digital
More information3/4 U CPCI Serial Case System
3/4 U CPCI Serial Case System User s Manual Product Number: 4579-634 Doc-No: 6397-345_R.0 October 05 R.0 October 05 Initial Release Impressum: Schroff GmbH Langenalber Str. 96-00 75334 Straubenhardt, Germany
More informationOracle <Insert Picture Here>
Slide 1 Oracle Slide 2 WZT-5160 SPARC T3 Based Servers Architecture and Features Welcome to the SPARC T3 Based Servers Architecture and Features module. This
More informationUser manual. Gaming 978BG - Tank-Buster
User manual Gaming 978BG - Tank-Buster Content Chapter 1 Product introduction 1.1 Specification...03 1.2 Accessory...04 Chapter 2 Installation guide 2.1 Side panel assembly...05 2.2 Motherboard installation...06
More informationInstallation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules
Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules
More informationPixus Technologies Catalog
The Power of Embedded Ingenuity Pixus Technologies Catalog Kaparel, Ripac, & Vario Brand Products www.pixustechnologies.com sales@pixustechnologies.com US: 916.524.8242 CN: 519.885.5775 Contents Kaparel/Rittal
More informationDYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, Calif Fax Est.
DYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, Calif. 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual PCI2PMC PCI Single Slot PMC Compatible Carrier
More informationEMC1600 Series Media Converter and Ethernet Extender Chassis
EMC1600 Series Media Converter and Ethernet Extender Chassis User s Manual Preface This manual describes how to install and use the 16-Bay Media Converter and Ethernet Extender Chassis. This chassis is
More informationCPCI Basic 1U, 2U and 4U User's Manual
CPCI Basic 1U, 2U and 4U User's Manual www.hartmann-elektronik.de Rev. 1.2 Rev: Date: R 1.0 19.04.2010 R 1.1 09.08.2011 R 1.2 25.06.2012 Impressum: Hartmann Elektronik GmbH Motorstraße 43, D-70499 Stuttgart
More informationMediaKind G7 Series. High Performance Intel-based Video Processing
MediaKind G7 Series High Performance Intel-based Video Processing The MediaKind G7 platform provides outstanding performance and density for and delivery applications and is available in 1RU (1000 series)
More informationCMX18 FEATURES A 18-SLOT 3U PXI EXPRESS CHASSIS
83-0062-000 15A D A T A S H E E T CMX18 18-SLOT 3U PXI EXPRESS CHASSIS FEATURES 18-slot PXI Express chassis with 1 system controller slot, 6 peripheral slots, 10 hybrid slots, and 1 timing slot High bandwidth
More informationFVT Slot Media Converter Chassis w/ Redundant Power User Manual
FVT-4000 10-Slot Media Converter Chassis w/ Redundant Power User Manual Ver. 1.00-0609 Table of Contents 1. INTRODUCTION... 1 1.1. FEATURES... 1 1.2. PACKAGE CONTENTS... 2 2. HARDWARE DESCRIPTION... 3
More informationReplacing an Advanced Power and Cooling (APC) Unit
Replacing an Advanced Power and Cooling (APC) Unit You must replace a failed APC unit as quickly as possible (within minutes) to maintain correct airflow and cooling. Failed APC units can be hot-swapped.
More informationCOMPUTING ATCA G ATCA Server Blade
COMPUTING Data Sheet The ATCA-7367 processor blade is an ideal solution for communications equipment requiring powerful processing performance, flexible I/O functionality plus mass storage and network
More informationVEROTEC Electronics Packaging
VEROTEC Electronics Packaging Integrated Integrated Introduction S Y S T E M S Introduction Verotec designs and manufactures a number of standard electronics packaging components and piece parts. These
More informationMicroTCA.4 /4.1 Hardware Standards & Software Guidelines Progress Overview
MicroTCA.4 /4.1 Hardware Standards & Software Guidelines Progress Overview Ray Larsen SLAC National Accelerator Laboratory for the xtca for Physics Collaboration TIPP 17Beijing PRC May 26, 2017 1 Standard
More informationChassis (FRU) Replacement Guide
SIEM9750 Release 1.0 Chassis (FRU) Replacement Guide Issue: 02 Date: 2011-11-07 Page 1 of 26 This document is intended for Symantec support personnel, IBM, or other authorized Symantec Service Partners.
More information