1 s Our technology knows no boundaries. Electrical Installations from A to Z Maximum etail Price w.e.f. st December,

2 Siemens Ltd. Electrical Installation MP Eff. 0--

3 Index Sr. No. Items Pg. No. Betagard 5SL Miniature Circuit Breakers -7 5SL, 7.5kA with C Characteristics 5SL, 7.5kA with B characteristics Sr. No. Items Pg. No. 0 Betagard Modular Devices - Changeover switches Insta Contactors 5SL, 0kA with C characteristics Betagard Miniature Circuit Breakers 8-9 5SX/5SJ, 0kA with D characteristics Insta contactors with manual switching Time Switches Voltage relays 3 5 5SP, 0kA with C and D characteristics Betagard DC Circuit Breakers 0 5SX5/5SJ5, 0kA DC Circuit Breakers Betagard Isolators 0 5TL Isolators Betagard esidual Current Circuit Breakers - 5SM3 CCB - Type AC 5SM3 CCB - Type A 5SM3 CCB - Type B Betagard esidual Current Breaker Operators 7 8 5SU CBO, 0kA, Type AC with C and D characteristics 5SU CBO, 0kA, Type A with C and D characteristics 5- Betagard Accessories 7 Betagard Distribution Boards 8-8GB - SPN and TPN DBs 8GB0 - SPN and TPN DBs Digital Ammeters & Voltmeters Indicators Fuse Monitors Surge Protection Devices Sentron MCCBs - 3VT,,3 ordering info 3 AJA Starters ordering info 3 Switch Disconnector Fuses - 3KT ordering info Fuses - 3NA/3NW ordering info Betagard 5SX C Curve MCBs and 5TE Isolators Energy meters for Distribution Boards 3 Customer Care Betagard MB DB in Appliance Protector and Industrial Plug and Socket DBs 8GB3 - Flexi, Bus, Bus Plus, Multi, CO DBs Simbox WP DBs Accessories for Betagard DBs Siemens Ltd. Electrical Installation MP Eff

4 Betagard 5SL MCBs Inspiring Safety Siemens has always endeavoured to introduce innovative products worldwide. Betagard 5SL MCBs offer numerous features - MCB with patented unique SL feature ISI and CE marking Unique square terminal design Terminal covers for extra production ohs complaint Accessories for special applications Very low watt loss,000 operations on rated load With SL IS/IEC MCB with patented unique SL (Slide Latch-elease) feature for tool free removal from DIN rail. It also allows individual MCB to be removed from bus bar mounted assembly without disturbing other devices BIS approval for ISI marking as per latest IS/ IEC 0898 :0 for assured quality and protection Unique design of square terminals to accommodate wire up to 35 Sq. mm Highly effective terminal covers for protection against accidental electrical contact Unique termination mechanism enables firm mounting of Bus bar together with wire; and provides front access to wires for safe installation Side mounting accessories like auxiliary switches, fault signaling contacts and lever locking device available for special applications Siemens Ltd. Electrical Installation MP Eff. 0--

5 Betagard 5SL Miniature Circuit Breakers C Characteristics IS/IEC Standards: IS/IEC 0898-:0 Voltage: Un /5V, 0Hz can be used in systems upto 0V DC for P and 0V DC for P With ISI marking: CM/L No ated Current I n (A) MW # eference No Unit MP* Pole SL057C 5SL07C 5SL07C 5SL037C 5SL07C 5SL07C 5SL087C 5SL07C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C / / / / / / / / / / / / / / / / Pole SL57C 5SL7C 5SL7C 5SL37C 5SL7C 5SL7C 5SL87C 5SL7C 5SL37C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL07C 5SL7C / / / / / / / / / / / / / / / / 3 Pole SL057C 5SL07C 5SL07C 5SL07C 5SL07C 5SL07C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C / / / / / / / / / / / / / Pole SL57C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C /3 /3 /3 /3 /3 /3 /3 /3 /3 /3 /3 /3 /3 Note: * MP - Maximum etail Price # MW (Module Width) = 8mm ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Siemens Ltd. Electrical Installation MP Eff

6 Betagard 5SL Miniature Circuit Breakers B Characteristics IS/IEC Standards: IS/IEC 0898-:0 Voltage: Un /5V, 0Hz can be used in systems upto 0V DC for P and 0V DC for P With ISI marking: CM/L No ated Current I n (A) MW # eference No Unit MP* Pole 0 5SL0C 5SL0C 5SLC 5SLC 5SLC 5SLC 5SLC 5SLC 5SLC / / / / / / / / / Pole 0 5SLC 5SLC 5SLC 5SLC 5SLC 5SLC 5SLC 5SL0C 5SLC / / / / / / / / / 3 Pole 0 3 5SL0C 5SL0C 5SLC 5SLC 5SLC 5SLC 5SLC 5SLC 5SLC / / / / / / / / / Pole 0 5SLC 5SLC 5SLC 5SLC 5SLC 5SLC 5SLC 5SLC 5SLC /3 /3 /3 /3 /3 /3 /3 /3 /3 Note: * MP - Maximum etail Price # MW (Module Width) = 8mm ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Siemens Ltd. Electrical Installation MP Eff. 0--

7 Betagard Miniature Circuit Breakers 5SL, 0kA with C characteristics New IS/IEC Standards: IS/IEC 0898-:0 Voltage: Un /5V, 0Hz can be used in systems upto 0V DC for P and 0V DC for P Breaking capacity: 0kA as per IS/IEC 0898-:0 With ISI marking: CM/L No ated Current I n (A) MW # eference No Unit MP* -pole SL57C 5SL7C 5SL37C 5SL7C 5SL7C 5SL87C 5SL7C 5SL37C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C / / / / / / / / / / / / / / / -pole SL57C 5SL7C 5SL37C 5SL7C 5SL7C 5SL87C 5SL7C 5SL37C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL07C 5SL7C / / / / / / / / / / / / / / / 3-pole SL57C 5SL7C 5SL37C 5SL7C 5SL7C 5SL87C 5SL7C 5SL337C 5SL37C 5SL07C 5SL37C 5SL37C 5SL37C 5SL37C 5SL37C / / / / / / / / / / / / / / / -pole SL57C 5SL7C 5SL37C 5SL7C 5SL7C 5SL87C 5SL7C 5SL37C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C 5SL7C /3 /3 /3 /3 /3 /3 /3 /3 /3 /3 /3 /3 /3 /3 /3 Note: * MP - Maximum etail Price # MW (Module Width) = 8mm ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Siemens Ltd. Electrical Installation MP Eff

8 Betagard Miniature Circuit Breakers 5SX/5SJ, 0kA with D characteristics IS/IEC Standards: IS/IEC 0898-:0 Voltage: Un /5V, 0Hz can be used in systems upto 0V DC for P and 0V DC for P Breaking capacity: 0kA as per IS/IEC 0898-:0 With ISI marking: CM/L No ated Current I n (A) MW # eference No Unit MP* -pole SX58C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SJ8C 5SJ8C 5SJ8C / / / / / / / / / / / / / -pole SX58C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SJ8C 5SJ08C 5SJ8C pole SX58C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SX38C 5SX08C 5SX38C 5SX38C 5SJ38C 5SJ38C 5SJ38C pole SX58C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SX8C 5SJ8C 5SJ8C 5SJ8C Note: * MP - Maximum etail Price # MW (Module Width) = 8mm ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details 8 Siemens Ltd. Electrical Installation MP Eff. 0--

9 Betagard Miniature Circuit Breakers 5SP, 0kA MCBs with C/D characteristics IS/IEC Standards: IS/IEC 0898-:0 Voltage: Un /5V, 0Hz can be used in systems upto 0V DC for P and 0V DC for P Breaking capacity: 0kA as per IS/IEC 0898-:0 With ISI marking: CM/L No. 558 C characteristic 0000 ated Current I n (A) MW # eference No Unit MP* -pole SP7C 5SP97C 5SP97C pole SP7C 5SP97C 5SP97C /5 /5 /5 3-pole SP37C 5SP397C 5SP397C D characteristic -pole 00 5SP7C 5SP97C 5SP97C pole SP8C 5SP98C pole SP8C 5SP98C /5 /5 3-pole SP38C 5SP398C pole 00 5SP8C 5SP98C Note: * MP - Maximum etail Price # MW (Module Width) = 8mm ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Siemens Ltd. Electrical Installation MP Eff

10 Betagard DC Circuit Breakers 5SX5/5SJ5, 0kA DC Circuit Breakers Standards: IS/IEC 097- Voltage: Vdc/P & Vdc/P Breaking capacity: 0kA as per IS/IEC ated Current I n (A) MW # eference No Unit MP* -pole SX57C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX57C 5SX57C 5SX57C 5SX57C 5SJ57C 5SJ57C 5SJ57C / / / / / / / / / / / / / -pole SX557C 5SX57C 5SX57C 5SX57C 5SX57C 5SX57C 5SX57C 5SX57C 5SX57C 5SX57C 5SJ57C 5SJ7C 5SJ57C Betagard Isolators New Standard: IS/IEC Voltage: V AC ated Current I n (A) -pole 00 MW # eference No Unit MP* 5TL 5TL 5TL 5TL0 5TL90 5TL / / / / / / 3-pole TL30 5TL 5TL 5TL30 5TL390 5TL / / / / / / -pole TL0 5TL0 5TL 5TL0 5TL90 5TL / / / / / / Note: * MP - Maximum etail Price # MW (Module Width) = 8mm ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details 0 Siemens Ltd. Electrical Installation MP Eff. 0--

11 Siemens Ltd. Electrical Installation MP Eff. 0--

12 Betagard esidual Current Circuit Breakers 5SM3 Standards: IS, Part :08/IEC 008-:99 Voltage: /5Vac, 0Hz With ISI marking: CM/L No Type AC, applicable in networks for AC residual currents ated residual current I n (ma) ated Current I n (A) MW # eference No Unit MP* Pole SM30C 5SM3C 5SM3C 5SM33C 5SM3C 5SM3C SM330C 5SM30C 5SM30C 5SM3370C 5SM370C 5SM370C SM33KK 5SM3KK 5SM3KK 5SM33KK 5SM3KK 5SM3KK Pole SM33C 5SM3C 5SM3C 5SM33C 5SM3C 5SM3C 5SM330C 5SM30C 5SM30C 5SM3370C 5SM370C 5SM370C 5SM33C 5SM3C 5SM3C 5SM33C 5SM3C 5SM3C 5SM37C Type A, applicable in networks with AC and/or pulsating DC residual currents Pole SM3C 5SM3C 5SM3C 5SM33C 5SM3C 5SM3C SM33C 5SM3C 5SM3C 5SM337C 5SM37C 5SM37C SM338KK 5SM38KK 5SM38KK 5SM335KK 5SM35KK 5SM35KK Note: * MP - Maximum etail Price # MW (Module Width) = 8mm ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Contd... Siemens Ltd. Electrical Installation MP Eff. 0--

13 Betagard esidual Current Circuit Breakers 5SM3 Standards: IS, Part :08/IEC 008-:99 Voltage: /5Vac, 0Hz With ISI marking: CM/L No Type A, applicable in networks with AC and/or pulsating DC residual currents ated residual current I n (ma) ated Current I n (A) MW # eference No Unit MP* Pole SM33C 5SM3C 5SM3C 5SM33C 5SM3C 5SM3C 5SM33C 5SM3C 5SM3C 5SM337C 5SM37C 5SM37C 5SM338C 5SM38C 5SM38C 5SM335C 5SM35C 5SM35C 5SM375C Super esistant K Pole 5SM3C0 5SM33C SM33C0 5SM3C Pole 5SM33C0 5SM33C0 5SM3C0 5SM33C0 5SM3C0 5SM37C Selective S Pole 5SM38C SM38C 5SM38C 5SM378C Pole SM38C 5SM38C 5SM38C 5SM38C 5SM358C 5SM3758C Note: * MP - Maximum etail Price # MW (Module Width) = 8mm ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Contd... Siemens Ltd. Electrical Installation MP Eff

14 Betagard esidual Current Circuit Breakers 5SM3 Standards: IS, Part :08/IEC 008-:99 Voltage: /5Vac, 0Hz With ISI marking: CM/L No Type B, applicable in networks with AC, pulsating DC and pure DC residual currents ated residual current I n (ma) ated Current I n (A) MW # eference No Unit MP* Super esistant K Pole 0 0 5SM33C 5SM3C 5SM33C 5SM3C 5SM33C 5SM3C 5SM37C 5SM337C 5SM37C 5SM377C Selective S Pole 0 0 5SM35C 5SM375C 5SM375C 5SM3775C Types of esidual Current Circuit Breakers (CCBs) Type AC: esidual current protective devices of type AC are suitable only for detecting sinusoidal AC residual current. Type A: In addition to sinusoidal AC residual currents, residual current protective devices of type A also measure pulsating DC residual currents. This device type is the most commonly used pulse currentsensitive residual current operated circuit-breaker. It also covers the residual current waveforms which can occur in power supply units (e.g. ECG, washing machines) in the case of single-phase loads with electronic components. Type B: In addition to detecting residual current waveforms of type A, residual current protective devices of type B are used to measure smooth DC residual currents. Possible residual current wave shapes and suitable residual current protective devices Note: * MP - Maximum etail Price # MW (Module Width) = 8mm ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Siemens Ltd. Electrical Installation MP Eff. 0--

15 Betagard esidual Current Breaker Operators 5SU, 0kA Standards: IS, Part :08/IEC 009-:99 Voltage: /5Vac, 0Hz With ISI marking: CM/L No Type AC with C characteristic Type AC with D characteristic ated residual current I n (ma) Vac; 0Hz; pole 00 5Vac; 0Hz; pole 00 ated Current I n (A) MW # eference No Unit MP* 5SUC 5SUC 5SUC 5SUC 5SUC 5SUC 5SUC 5SUC 5SUC 7 5SU3C 5SU3C 5SU3C 5SUC 5SUC 5SUC 5SUC 5SUC 5SUC /5 /5 /5 /5 /5 /5 /5 /5 /5 Vac; 0Hz; pole 00 5Vac; 0Hz; pole 00 5SUC 5SUC 5SUC 5SUC 5SUC 5SUC 5SUC 5SUC 5SUC 7 5SU3C 5SU3C 5SU3C 5SUC 5SUC 5SUC 5SUC 5SUC 5SUC /5 /5 /5 /5 /5 /5 /5 /5 /5 Type AC, with C Characteristics (in module size) pole + N 0 0 5SU35C0 5SU35C0 5SU35C 5SU35C 5SU35C 5SU35C 5SU35C 5SU5C0 5SU5C0 5SU5C 5SU5C 5SU5C 5SU5C 5SU5C Note: * MP - Maximum etail Price # MW (Module Width) = 8mm ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Contd... Siemens Ltd. Electrical Installation MP Eff

16 Betagard esidual Current Breaker Operators 5SU, 0kA Standards: IS, Part :08/IEC 009-:99 Voltage: /5Vac, 0Hz With ISI marking: CM/L No Type A with C characteristic Type A with D characteristic ated residual current I n (ma) Vac; 0Hz; pole 00 5Vac; 0Hz; pole 00 Vac; 0Hz; pole 00 5Vac; 0Hz; pole 00 Type A, with C Characteristics (in module size) pole + N ated Current I n (A) 0 0 MW # eference No Unit MP* 5SU7C 5SU7C 5SU7C 5SU7C 5SU7C 5SU7C 5SU7C 5SU7C 5SU7C 7 5SU37C 5SU37C 5SU37C 5SU7C 5SU7C 5SU7C 5SU7C 5SU7C 5SU7C 5SU8C 5SU8C 5SU8C 5SU8C 5SU8C 5SU8C 5SU8C 5SU8C 5SU8C 7 5SU38C 5SU38C 5SU38C 5SU8C 5SU8C 5SU8C 5SU8C 5SU8C 5SU8C 5SU357C0 5SU357C0 5SU357C 5SU357C 5SU357C 5SU357C 5SU357C 5SU57C0 5SU57C0 5SU57C 5SU57C 5SU57C 5SU57C 5SU57C /5 /5 /5 /5 /5 /5 /5 /5 /5 /5 /5 /5 /5 /5 /5 /5 /5 /5 Note: * MP - Maximum etail Price # MW (Module Width) = 8mm ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Siemens Ltd. Electrical Installation MP Eff. 0--

17 Betagard Accessories Common accessories for 5SL / 5SJ / 5SJ5 / 5SP MCBs and 5SU Not suitable for Betagard 5SL MCB s $ Suitable for 5SU CBO only Item Description eference No Unit MP* Aux contact block, NO+NC 5ST 75.- Fault signal contact, NO+NC 5ST Shunt release, 0 5ST 5.- /5 Shunt release, 5ST /5 Undervoltage release, 5ST3 5.- /5 Undervoltage release, 5ST5 5.- /5 Motorized drive, Vac, 5ST 35.- Lever locking device for padlock with max. mm shackle 5ST Coupler for accessory mounting (set of 5) $ 5ST Common accessories for 5SX / 5SX5 MCBs Item Description eference No. Unit MP* Aux contact block, NO+NC 5SX Aux contact block, NO 5SX Fault signal contact, NO+NC 5SX Shunt release, 0 5Vac 5SX /5 Accessories for 55 mm devices (5SX MCBs/5TE Isolators) Item Description eference No. Unit MP* Vertical Spacer 5ST.- 0 Accessories for Betagard esidual Current Circuit Breakers, Type 5SM3 Item Description eference No. Unit MP* Aux contact block NO+NC, A to A 5SW Aux contact block NO+NC, 00A to A 5SW Betagard otary Handle Assembly Item Description eference No. Unit MP* otary Handle Assembly for 5SJ, 5SY, 5SL, 5SP and 5TE8 series of MCBs/ Isolators 5ST38C.- Note: * MP - Maximum etail Price Siemens Ltd. Electrical Installation MP Eff

18 8 Siemens Ltd. Electrical Installation MP Eff. 0--

19 Betagard Distribution Boards 8GB SPN and TPN DBs Type Tested as per IEC 39 / Standards at neutral third party and internal test laboratories. Available in IP and IP 3 Versions. Single Door, Metal Double Door and Acrylic Double Door options available. Standard Wire Way Boxes available for all single Door and Double Door DBs. Additional safety to users and Installers by Insulated Shorting Links, Shrouded Neutral Links and Door Earthing. TPN DBs can be easily made suitable for PPI configuration using TPN to PPI Conversion Kits. Detachable Din rail assembly and intermittent door facilitates ease in Wiring during installation and maintenance. DBs are manufactured by latest technology with 8 SWG and SWG CCA Steel. DBs are subjected to seven tanks Process and treated with Premier quality powder coating. Cement Masking Sheet protects the DBs against extreme site conditions. DBs are supplied in Dual Packing for safety during transit and storage. Item Description Incoming Outgoing Total eference No Unit MP* Std. Pkg.** Metal Enclosures, IP: Module 8GB00C / Module 8GB00C0 0.- / 3 Module 3 8GB00C / Module 8GB00C0 0.- / Module 8GB00C0 5.- / 8 Module 8 8GB00C SPN Single Door DBs, IP: Module 8GB0C Module 8 8GB0C Module 8 0 8GB0C Module 0 8GB0C 3.- Module 8GB0C 95.- Module 8GB0C 05.- SPN Metal Double Door DBs, IP 3: Module 8GB0C0.- 8 Module 8 8GB0C Module 8 0 8GB0C Module 0 8GB0C.- Module 8GB0C Module 8GB0C.- SPN Acrylic Double Door DBs, IP 3: Module 8GB03C Module 8 8GB03C Module 8 0 8GB03C Module 0 8GB03C 5.- Module 8GB03C.- Module 8GB03C Wire Way Box For SPN Single Door IP DBs: For MOD SPN Single door DB 8GB0C /5 For 8 MOD SPN Single door DB 8GB0C /5 For 0 MOD SPN Single door DB 8GB0C /5 For MOD SPN Single door DB 8GB0C 75.- /5 For MOD SPN Single door DB 8GB0C 80.- /5 For MOD SPN Single door DB 8GB0C 80.- /5 Wire Way Box For SPN Double Door IP 3 DBs: For MOD SPN Double door DB 8GB07C /5 For 8 MOD SPN Double door DB 8GB07C /5 For 0 MOD SPN Double door DB 8GB07C0 5.- /5 For MOD SPN Double door DB 8GB07C 5.- /5 For MOD SPN Double door DB 8GB07C 0.- /5 For MOD SPN Double door DB 8GB07C 0.- /5 Note: * MP - Maximum etail Price For Customized Solutions in Distribution Boards please Contact our sales Office ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Contd... Siemens Ltd. Electrical Installation MP Eff

20 Betagard Distribution Boards 8GB SPN and TPN DBs Item Description Incoming Outgoing Total eference No Unit MP* TPN Single Door DBs, IP: way 8 8GBC way 8 8 8GBC way 8 8GBC way GBC way 8 3 8GBC.- way 8 8GBC 95.- way GBC.- TPN Metal Double Door DBs, IP 3 way 8 8GBC0 5.- way 8 8 8GBC way 8 8GBC way GBC way 8 3 8GBC way 8 8GBC way GBC 85.- TPN Acrylic Double Door DBs, IP 3 way 8 8GB3C way 8 8 8GB3C way 8 8GB3C way GB3C way 8 3 8GB3C 85.- way 8 8GB3C 9.- way GB3C TPN to PPI Conversion To convert way TPN DB to way TPN PPI DB 8GB5C0.- /5 To convert 8 way TPN DB to way TPN PPI DB 8GB5C /5 To convert 0 way TPN DB to 8 way TPN PPI DB 8GB5C08.- /5 To convert way TPN DB to 0 way TPN PPI DB 8GB5C0 5.- /5 To convert way TPN DB to way TPN PPI DB 8GB5C /5 To convert way TPN DB to way TPN PPI DB 8GB5C 90.- /5 Wire Way Box For TPN Single Door IP DBs For Way TPN Single door DB 8GBC /5 For Way TPN Single door DB 8GBC /5 For 8 Way TPN Single door DB 8GBC /5 For 0 Way TPN Single door DB 8GBC0 9.- /5 For Way TPN Single door DB 8GBC /5 For Way TPN Single door DB 8GBC.- /5 For Way TPN Single door DB 8GBC 5.- /5 Wire Way Box For TPN Double Door IP 3 DBs For Way TPN Double door DB 8GB7C /5 For Way TPN Double door DB 8GB7C0 0.- /5 For 8 Way TPN Double door DB 8GB7C08.- /5 For 0 Way TPN Double door DB 8GB7C /5 For Way TPN Double door DB 8GB7C 5.- /5 For Way TPN Double door DB 8GB7C 75.- /5 For Way TPN Double door DB 8GB7C 3.- /5 Std. Pkg.** Note: * MP - Maximum etail Contains required accessories to Make the DB suitable for PPI Configuration For Customized Solutions in Distribution Boards please Contact our sales Office ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Siemens Ltd. Electrical Installation MP Eff. 0--

21 Betagard Distribution Boards 8GB0 SPN and TPN DBs Plastic Enclosure, IP: Item Description Incoming Outgoing Total eference No Unit MP* / Way 8GB / Way 8GB / Way 8GB / Double Door SPN DBs, IP : Way 8GB0C Way 8 8GB0C.- 8 Way 8 0 8GB08C 9.- Way 8GB0C 95.- Way 8GB0C Double Door TPN DBs (Horizontal), IP : Way 8 8GB0HC 0.- Way 8 8 8GB0HC Way 8 8GB08HC.- Way 8 3 8GB0HC 75.- Double Door TPN DBs (Vertical), IP : Way 8 8GB0VC.- Way 8 8 8GB0VC Way 8 8GB08VC 5.- Way 8 3 8GB0VC 7.- Double Door, Per Phase Isolation TPN DBs (Horizontal), IP : Way 8 8 8GB05HC 50.- Way 8 8GB07HC Way GB09HC 83.- Way 8 8GB03HC Double Door, Per Phase Isolation TPN DBs (Vertical), IP : Way 8 8 8GB05VC 75.- Way 8 8GB07VC Way GB09VC 90.- Way 8 8GB03VC 5.- Double Door, Phase Segregated TPN DBs (7 segment), IP: Way + 3 8GB Way +8 8GB Way + 8 8GB Way GB Siemens Ltd. Electrical Installation MP Eff. 0--

22 Betagard Distribution Boards MB DBs Item Description Incoming Outgoing Total eference No Unit MP* Betagard MB (Ivory White) : ow, Mod 8GB3C0 3.- ow, 8Mod 8 8GB38C ow, 0Mod 8 0 8GB38C ow, Mod 0 8GB383C0 8.- ow, Mod 8GB38C ow, Mod 8GB385C0.- Betagard MB (Metallic Grey) : ow, Mod 8GB3C ow, 8Mod 8 8GB38C ow, 0Mod 8 0 8GB38C0 8.- ow, Mod 0 8GB383C ow, Mod 8GB38C0 5.- ow, Mod 8GB385C0.- Betagard MB (Metallic Carbon) : ow, Mod 8GB3C ow, 8Mod 8 8GB38C ow, 0Mod 8 0 8GB38C ow, Mod 0 8GB383C ow, Mod 8GB38C ow, Mod 8GB385C03.- Betagard Distribution Boards in Appliance Protector & Industrial plug & sockets Item Description Total eference No Unit MP* Plug & Socket, IP with provision for MCB mounting : Phase A, P MCB 8GB0C 5.- / Phase A, P MCB 8GB0SC 5.- / 3 Phase A, 3P MCB 3 8GB /5 3 Phase A, 3P+N MCB 8GB0S 85.- /5 5 Pin (3P+N+PE) 3Phase A MCB 3P+N MCB 8 8GB /5 5 Pin (3P+N+PE) 3Phase A MCB 3P+N MCB 8 8GB /5 in Appliance Protector Pre Wired, IP with factory fitted Betagard 5SL MCB : Flush Mounting in, FM with A,P MCB and 0/A socket 8GBC / in, FM with A,P MCB and 0/A socket 8GBC 5.- / in, FM with A,P MCB and A socket 8GBC 05.- / in, FM with A,P MCB and A socket 8GBC 95.- / Surface Mounting in, SM with A, P MCB and /A Socket 8GB30C 5.- / in, SM with A, P MCB and /A Socket 8GB30C 9.- / in, SM with A,P MCB and 0/A socket 8GB3C 7.- / in, SM with A, P MCB and 0/A socket 8GB3C / in, SM with A,P MCB and A socket 8GB3C / in, SM with A, P MCB and A socket 8GB3C / Note: * MP - Maximum etail Price For Customized Solutions in Distribution Boards please Contact our sales Office ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Siemens Ltd. Electrical Installation MP Eff. 0--

23 Betagard Distribution Boards 8GB3 Item Description Incoming Outgoing Total eference No Unit MP* Betaflex (Flexi DBs), IP : ow x Mod 8GB3C ow x Mod 8GB3C 39.- ow x 8Mod 8GB3C.- ow x Mod 8 8GB3C 95.- ow x Mod 8GB3C Betabus (Vertical Busbar DBs with MCB as an incomer), IP : (Suitable for 5SL/5SX/5SJ/5SP MCBs, upto A as an incomer) way 8GB37C way 8 8GB373C way 3 8GB37C way 3 8 8GB377C Betabusplus (Vertical Busbar DBs with MCCB as an incomer), IP : (Suitable for 3VT MCCBs, upto 0A as an incomer) way 8GB357C way 8 8GB357C way 3 8GB3573C 0.- way 3 8 8GB357C BetaMulti (DBs for power & communication), IP : way SPN, provision 8GB3C.- Way TPN, Provision 8 8GBC 75.- way TPN, provision 8 8 8GBC Way TPN Provision 8 8GBC way SPN, built-in 8GB335C 50.- Way TPN, Built-in 8 8GB30C 95.- way TPN, built-in 8 8 8GB3C Way TPN, Built-in 8 8GB3C 7.- Beta CO (DBs with provision for phase changeover switches), IP : way, with provision 8 8GB38C 75.- way, with provision 8 8 8GB38C way, with provision 8 8GB38C way, with provision 8 3 8GB38C Beta CO (DBs with built-in pre-wired phase changeover switches), IP : A, Way TPN, built-in 8 8GB38C 05.- A, Way TPN, built-in 8 8 8GB385C A, 8 Way TPN, built-in 8 8GB385C 0.- A, Way TPN, built-in 8 3 8GB385C.- A, Way TPN, built-in 8 8GB380C A, Way TPN, built-in 8 8 8GB38C A, 8 Way TPN, built-in 8 8GB38C 90.- A, Way TPN, built-in 8 3 8GB38C Note: * MP - Maximum etail Price For Customized Solutions in Distribution Boards please Contact our sales Office ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Contd... Siemens Ltd. Electrical Installation MP Eff

24 Betagard Distribution Boards 8GB3 Item Description Incoming Outgoing Total eference No Unit MP* Wire Way Boxes (WWB) WWB for Flexi DB,8Mod 8GB9908FWWNT /5 WWB for Flexi DB,Mod 8GB99FWWNT 05.- /5 WWB for Flexi DB,Mod 8GB99FWWNT 3.- /5 WWB for Bus DB 8GB99BUSWWNT 95.- /5 WWB for Bus Plus DB 8GB99BPLUSWWNT 05.- /5 Modular Device Boxes (MDB) MDB for Flexi DB, 8Mod/ow 8 8GB9908FMDTC.- /5 MDB for Flexi DB,Mod/ow 8GB99FMDTC /5 MDB for Flexi DB,Mod/ow 8GB99FMDTC 55.- /5 MDB for Bus DB 8GB99BUSMBTC 75.- /5 MDB for Bus Plus DB 8GB99BPLUSMBTC /5 Betagard Distribution Boards Simbox WP Simbox WP (IP5 DBs) Item Description Total eference No Unit MP* ow, Mod 8GB ow 8Mod 8 8GB ow Mod 8GB ow 8Mod 8 8GB ow x Mod 8GB ow, x 8Mod 3 8GB ow, 3 x 8Mod 5 8GB ow x 8Mod 7 8GB Accessories for Simbox WP Coupling covers,m 8GB Coupling covers,8m 8GB Insulated N/PE terminals, 8MW 8GB Insulated N/PE terminals, MW 8GB Insulated N/PE terminals, 8MW 8GB5 3.- Cylindrical security lock 8GB Note: * MP - Maximum etail Price For Customized Solutions in Distribution Boards please Contact our sales Office ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Siemens Ltd. Electrical Installation MP Eff. 0--

25 Betagard Distribution Boards Accessories Blanking Plate Item Description eference No Unit MP* MW 8GB MW 8GB Insulated Shorting Links Suitable For SPN and TPN PPI DBs Single Phase (For shorting P MCBs in TPN DBs) Two Phase (For shorting P MCBs) Three Phase (For shorting 3P MCBs) Three Phase Neutral (For Shorting P MCBs) 5 Leg SP Shorting Link (For Way SPN DB and Way PPI DB) 8GB9905LSP Leg SP Shorting Link (For Way SPN DB and Way PPI DB) 8GB9907LSP Leg SP Shorting Link (For 8 Way SPN DB and 8 Way PPI DB) 8GB9909LSP Leg SP Shorting Link (For 0 Way SPN DB and 0 Way PPI DB) 8GB99LSP Leg SP Shorting Link (For Way SPN DB and Way PPI DB) 8GB993LSP Leg SP Shorting Link (For Way SPN DB and Way PPI DB) 8GB995LSP Leg SP Shorting Link (For Way SPN DB and Way PPI DB) 8GB997LSP Leg SP Shorting Link (For Way TPN DB) 8GB990LSP Leg SP Shorting Link (For Way TPN DB) 8GB990LSP Leg SP Shorting Link (For 8 Way TPN DB) 8GB9908LSP Leg SP Shorting Link (For 0 Way TPN DB) 8GB990LSP Leg SP Shorting Link (For Way TPN DB) 8GB99LSP.- 0 Leg SP Shorting Link (For Way TPN DB) 8GB99LSP.- 0 Leg SP Shorting Link (For Way TPN DB) 8GB99LSP Way DP Shorting Link (For Shorting Nos of P MCBs) 8GB990LDP Way DP Shorting Link (For Shorting Nos of P MCBs) 8GB990LDP Way DP Shorting Link (For Shorting 8 Nos of P MCBs) 8GB9908LDP Way TP Shorting Link (For Shorting Nos of 3P MCBs) 8GB990LTP Way TP Shorting Link (For Shorting Nos of 3P MCBs) 8GB990LTP Way TP Shorting Link (For Shorting 8 Nos of 3P MCBs) 8GB9908LTP Way TPN Shorting Link (For Shorting Nos of P MCBs) 8GB990LTPN Way TPN Shorting Link (For Shorting Nos of P MCBs) 8GB990LTPN Way TPN Shorting Link (For Shorting 8 Nos of P MCBs) 8GB9908LTPN Neutral Terminals Neutral Terminals For 8GB3 DBs Neutral Terminals for Way Circuits 8GB990NSPE Neutral Terminals for Way Circuits 8GB990NSPE Neutral Terminals for 8 Way Circuits 8GB9908NSPE.- 0 Neutral Terminals for Way Circuits 8GB99NSPE Neutral Terminals for Way Circuits 8GB99NSPE Neutral Terminals For 8GB DBs (With Terminal Shroud and Cover) Neutral Terminal 5 Holes 8GB9905NPE.- 0 Neutral Terminal Holes 8GB99NPE Neutral Terminal 3 Holes 8GB993NPE.- 0 Neutral Terminal 5 Holes 8GB995NPE Note: * MP - Maximum etail Price # Way - Denotes No of MCBs at the Outgoing ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Siemens Ltd. Electrical Installation MP Eff. 0--

26 Modular Devices Item Description Changeover switches Standards: IEC 097-3/DIN EN ated Current I n (A) MW # eference No Unit MP* C/O, V 5TE C/O, 0V 5TE Group switch, center position, C/O, 0V 5TE Insta Contactors Standards: EN 097--, EN NO contacts, Vac 5TT /5 3NO+NC contacts, Vac/Vdc (NC contact rated for A) 3NO+NC contacts, Vac/Vdc (NC contact rated for A) 3 5TT /5 3 5TT /5 NO contacts, Vac/Vdc 3 5TT /5 NO contacts, Vac/Vdc 3 5TT /5 3NO+NC contacts, Vac/Vdc (NC contact rated for A) 3NO+NC contacts, Vac/Vdc, (NC contact rated for A) 3 5TT /5 3 5TT /5 NO contacts, Vac/Vdc 3 5TT580.- /5 NO contacts, Vac/Vdc 3 5TT /5 Insta Contactors with Manual Switch O/I/Automatic and switching position indication Standards: IEC097--, IEC NO contacts, Vac 5TT.- /5 NO+NC contacts, Vac 5TT5 8.- /5 NO contacts, Vac 5TT /5 NO contacts, 0Vac 3 5TT /5 NO contacts, 0Vac 3 5TT /5 Accessories Control Switch with Make and Break Contact For AC V/0V For 5TT58 and 5TT 5TT Note: * MP - Maximum etail Price # MW (Module Width) = 8mm ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Contd... Siemens Ltd. Electrical Installation MP Eff. 0--

27 Modular Devices Time Switches (Digital) Time Switches (Mechanical) Standards: EN 07- Item Description Mini digital, daily/weekly program, 00 hours reserve, Vac Yearly time switch top digital V, channel Yearly time switch top digital V, channel Weekly time switch profi digital V, channel Weekly time switch profi digital V, channel Weekly time switch astro digital V, channel Weekly time switch astro digital V, channel Expert digital, daily/weekly/yearly program, 5 years reserve, /Vac, channels system Quartz-clock time switches with power reserve for wall mounting, day disk, CO, 0Vac Synchronous time switches without power reserve, for wall mounting, day disk, CO, 0Vac ated Current I n (A) MW # eference No Unit MP* 7LF LF 8.- 7LF LF LF LF LF.- 7LF LF5 5.- /5 7LF5 3.- /5 Accessories for Digital Time Switches Data key for storing & transferring data (Expert) 7LF USB adapter and software 7LF Data key profi, astro 7LF9.- Note: * MP - Maximum etail Price # MW (Module Width) = 8mm ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Contd... Siemens Ltd. Electrical Installation MP Eff

28 Modular Devices Item Description Voltage elays Standards : IEC 05, DIN VDE Ammeters & Voltmeters Voltage relay for undervoltage monitoring of,,3 phases against N with phase failure detection, Switching thresholds xV, not adjustable; C/O contacts, A, /0Vac Voltage relay for undervoltage monitoring of,,3 phases against N, short time failure detection with phase failure detection and N conductor monitoring, Switching thresholds xV, not adjustable; C/O contacts, /0Vac Voltage relay for over and undervoltage monitoring of 3 phases against N with asymmetry, reverse voltage and phase failure detection with N conductor monitoring and adj. Time delay of 0. to s, Switching thresholds: U/voltage 0.7-.xV, % hysteresis, adjustable, O/voltage 0.9-.xV, % hysteresis, adjustable; C/O contacts, /0Vac Neutral conductor monitor with asymmetry detection and N conductor monitoring, C/O contacts, /0Vac ated Current I n (A) MW # eference No Unit MP* 5TT TT TT TT Digital Voltmeter, 00Vac 7KT /5 Digital Ammeter, direct connection 0. A (With CTs /5) 7KT 37.- /5 Measuring Selector Switches Measuring Selector switches are used as CO contacts of the phase for voltages and currents in 3-phase systems for Voltmeters and Ammeters. The design of these switches is adapted to match the modular installation devices. They support use in compliance with EN The device has a rated insulation voltage of 0V. This permits use in many systems. Measuring Selector Switches Item Description Voltmeter Selector Switches Ammeter Selector Switches for Transformer operation Voltage V AC Voltage V DC Current A AC MW # eference No Unit MP* 0 3 7KT KT Note: * MP - Maximum etail Price # MW (Module Width) = 8mm Contd... 8 Siemens Ltd. Electrical Installation MP Eff. 0--

29 Modular Devices YG 3 phase indicator in MW Item Description ated Current I n (A) MW # eference No Unit MP* 3 phase indicator (all with green color cap) 5TE phase indicator (red/yellow/green) 5TE Transparent cap ( set = 3 items,, Y, G lens) 5TG70.- Power ON Indicator (Economy Version ) Vac, Phase Light indicators for max. cable length up to 5 m with red lamp Light indicators for max. cable length up to 0 m with red lamp 5TE 8.- / 5TE / Transparent cap (ed) 5TG Transparent cap (Yellow) 5TG Transparent cap (Blue) 5TG Transparent cap (Green) 5TG Fuse Monitor Fuse monitors with transparent caps for all low voltage fuse systems, Vac 5TT Note: * MP - Maximum etail Price # MW (Module Width) = 8mm Siemens Ltd. Electrical Installation MP Eff

30 Modular Devices Type Lightning Arrestors Type Lightning Arresters include the system cables in the equipotential bonding, which protect the low-voltage systems against the over voltages and high surge currents that can be triggered by direct or indirect lighting strikes. The protection level of is lowered to.5kv by the lightning arrester, which reduces the load on the plant if a lightning strike is discharged. The lightning arrester are enclosed and are suitable for installation in the precounter area. All spark gaps are tripped, so that decoupling reactors are no longer required for the installation of overvoltage protection devices. The lightning arresters are tested by wave-shaped lighting impulse,...00ka with Wave form 0/3µs. Type Surge Arrester Surge Arresters type are used downstream of Lightning Arresters Type in main distribution boards or sub-distribution boards. They protect Low Voltage systems against transient over voltages. The type surge arresters lowers the level of protection to. to.5kv. Type 3 Surge Arrester Type 3 Surge Arresters are installed downstream of the type surge arresters in Sub-Distribution Boards close to the loads in Single or multiphase systems and further limit the over voltage in order to protect the connected loads. Surge protection Devices Item Description Type Discharge Capacity ka MW # eference No Unit MP* Lightning Arrestor Type, equi. Class B, UC 3V, Protection Blocks Plug In 3 pole, 3+0 Circuit. For TN-C Systems with emote Display Lightning Arrestor Type, equi., Class B, UC 3V, Protection Blocks Plug -In Pole, 3+ Circuit for TN-S and TT Systems Surge Arrestor Type, equi., Class C, UC 3V, Protection Blocks Plug -In 3 Pole, 3+0 Circuit for TNC Systems Surge Arrestor Type, equi Cat.C, UC 3VAC, Protection Blocks Plug In pole, 3+ Circuit for TN-S and TT systems Surge Arrestor type, equirement Class C, UC3V Protection Blocks Plug In Pole, L-N Circuit Surge Arrestor type, equirement Class C, UC0V Protection Blocks Plug In Pole, N-PE Circuit Surge Arrestor type 3, equirement Class D, ated Voltage UNV, UC75V DC / 3 V AC, Pole, for -Phase Power Supply Type 75 5SD Type SD Type 3 5SD Type 5SD Type 5SD Type 5SD Type 3 0 5SD7 9.- Plug part Type N-PE, equirement Class B, UC 3V -Pole For Lighting Conductor 5SD7 Type - 5SD Plug part Type L-N, equirement Class C,UC 3V -Pole For Surge Arrestor 5SD7... Plug part Type N-PE, equirement Class C, UC 0V -Pole For Surge Arrestor 5SD7, 5SD77, 5SD7 Plug Part Type 3 equirement Class D ated Voltage UN V pole, - Phase For Surge Arrestor 5SD7 Type - 5SD Type - 5SD Type 3-5SD Note: * MP - Maximum etail Price # MW (Module Width) = 8mm ** Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details Siemens Ltd. Electrical Installation MP Eff. 0--

31 Moulded Case Circuit 3VT,, 3 MCCBs 3VT #, 5 V AC, Hz MCCB, Thermal Magnetic elease for line protection (Fixed Overload & Fixed Short Circuit Settings) ated Current, A 3VT eference No. 3 pole Unit MP* 3VT eference No pole Unit MP* 3VT70-DA3-0AA0 3VT70-EA-0AA0 3VT70-DA3-0AA0 3VT70-EA-0AA0 3VT708-DA3-0AA0 3VT708-EA-0AA0 00 3VT70-DA3-0AA0 3VT70-EA-0AA0 3VT7-DA3-0AA0 3VT7-EA-0AA0 0 3VT7-DA3-0AA0 3VT7-EA-0AA0 Std. Pkg. (Adjustable Overload & Adjustable Short Circuit Settings) ated Current, A 3VT eference No. 3 pole Unit MP* 3VT eference No pole Unit MP* 3VT70-DC3-0AA0 3VT70-EC-0AA0 3VT79-DC3-0AA0 3VT79-EC-0AA0 3VT703-DC3-0AA0 3VT703-EC-0AA0 3VT70-DC3-0AA0 3VT70-EC-0AA0 3VT70-DC3-0AA0 3VT70-EC-0AA0 3VT708-DC3-0AA0 3VT708-EC-0AA0 00 3VT70-DC3-0AA0 3VT70-EC-0AA0 3VT7-DC3-0AA0 3VT7-EC-0AA0 0 3VT7-DC3-0AA0 3VT7-EC-0AA0 Std. Pkg. 3VT/3, 5 V AC, Hz MCCB, Microprocessor based elease for line protection (Adjustable Overload & Adjustable Short Circuit Settings) ated Current, A 3VT/3 (Base Unit) eference No. 3 pole Unit MP* 3VT/3 (Base Unit) eference No pole Unit MP* ETU eference No. 3VT & 3, 3kA 0A 3VT7-AA3-0AA0 3VT7-AA-0AA0 3VT9-AC00 0A 3VT7-AA3-0AA0 3VT7-AA-0AA0 3VT9-AC00 0A 3VT37-AA3-0AA0 3VT37-AA-0AA0 3VT93-AC00 0A 3VT37-AA3-0AA0 3VT37-AA-0AA0 3VT93-AC00 Accessories 3VT eference No. Unit MP* 3VT eference No Unit MP* 3VT3 eference No. Auxiliary Switch $ 3VT900-AB0 3VT9-AC0 3VT9-AC0 Alarm Switch ^ 3VT900-AH0 3VT9-AD0 3VT9-AD0 Door mounted otary handle 3VT900-3HQ00 3VT90-3HQ00 3VT9-3HQ00 Unit MP* Unit MP* Note : The ordering of Microprocessor based MCCB s above 0A includes ordering of Base Unit + Electronic Trip Unit (ETU) separately $ Auxiliary switch for 3VT is C/O & for 3VT,3 is NO; ^ Alarm switch for 3VT is C/O & for 3VT,3 is NC; # 3VT MCCBs are suitable for mounting in Beta Bus Plus Distribution Kindly refer latest Power Distribution Products Price List for prices aja DOL 3TW Direct On Line Starters Ue: 5V, 3ph, Hz DOL Starter in sheet steel housing, including bimetal relay with single phasing protection Motor rating HP kw elay ange A eference No ) Unit MP* Std. Pkg TW 90-A. 3TW 90-A. 3TW 90-A.8 3TW 90-A.9 3TW 90-A.7 3TW 90-A.7 3TW 90-A.7 3TW 90-A.75 3TW 90-A.77 3TW 90-A.78 ) Enter code for coil voltage, Hz (B for 0-0V, W for 5V) * MP - Maximum etail Kindly refer latest Motor Control Products Price List for prices Siemens Ltd. Electrical Installation MP Eff

32 Switch disconnector Superswitch 3KT8 in open execution TPN Ue: V, Hz; Standards: IS / IEC ated current, Ie, A HC fuse type eference No Unit MP* DIN BS 3KT8-3HA00 3KT8-3HA00 3KT8-3HA00 3KT8-3HA00 3KT8-3HA00 3KT83-3HA00 3KT83-3UA00 3KT8-3UA00 3KT833-3UA00 3KT83-3UA00 3KT8-3UA00 3KT8-3UA00 3KT83-3UA00 3KT8-3HJ00 3KT8-3HJ00 3KT8-3HJ00 Std. Pkg. Selection table for SS Housing for 3KT8 ated current Ie (A) eference No Unit MP* Std. Pkg. 3KT8 (-A) 3KT8 (00-0A) 3KT83 (0-0A) 3KT8 (0-0A) 3KX855-AC 3KX835-AC 3KX835-AC 3KX835-5AC LV HC DIN Type Fuse ated voltage: 0 V AC Size ated current A eference No 3NA7-0C 3NA7-0C 3NA7-0C 3NA7 3-0C 3NA7 5-0C 3NA7 7-0C 3NA7-0C 3NA7 8-0C 3NA7 87-0C 3NA7 8-0C 3NA7 8-0C 3NA7 8-0C 3NA7 8-0C 3NA7 8-0C 3NA7 83-0C 3NA7-0C 3NA7-0C 3NA7-0C 3NA7-0C 3NA7-0C 3NA7 3-0C 3NA7-0C 3NA7-0C 3NA7-0C # 0 & 0A fuses - ated voltage at 5 V AC Unit MP* Std. Pkg. Note: * MP - Maximum etail Kindly refer latest Power Distribution Products Price List for prices 5/0 BS Fuses Type Offset Tag Size ated current A # # ated current A 0 eference No 3NA7-0C 3NA7-0C 3NA7-0C 3NA7 0-0C 3NA3 35-0C 3NA3 30-0C 3NA3 35-0C 3NA3 37-0C 3NA3 375-C eference No 3NW TIA 3NW TIA 3NW TIA 3NW TIA0 3NW TIA 3NW TIA 3NW TIA 3NW TIA 3NW TIS 3NW TIS 3NW TIS Unit MP* Unit MP* Std. Pkg. /5 Std. Pkg. Siemens Ltd. Electrical Installation MP Eff. 0--

33 Available till stocks last (Check with our Authorised Dealers for Stock Availability before Order Placement) IS/IEC Betagard Miniature Circuit Breakers : 5SX, 0kA with C characteristics ated Current I n (A) MW # eference No Unit MP* Std. Pkg. -pole SX57C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C / / / / / / / / / / / / / -pole SX57C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX07C 5SX7C pole SX57C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX37C 5SX07C 5SX37C 5SX37C 5SX37C 5SX37C 5SX37C pole SX57C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C 5SX7C Betagard Isolators -pole 00 3-pole -pole 00 Note: * MP - Maximum etail Price # MW (Module Width) = 8mm 5TE39037Y 5TE3907Y 5TE3937Y 5TE3957Y 5TEDA 3 5TE39057Y 5TE3907Y 5TE39077Y 5TE397Y 5TE39087Y 5TE3907Y 5TE397Y 5TE3977Y 5TE0DA Siemens Ltd. Electrical Installation MP Eff

34 7KT Meters on LAN Networks for DB level Energy Management Highlights DIN rail mounting meters with communication LAN Coupler with Integrated WEB Browser LAN Internal memory of LAN Coupler -GB LAN Coupler eadymade eports in csv format(ms EXCEL) for easy analysis 7KT PAC 0 with S 85 Communication Module Easy integration in existing Building Management System No permanent connection to PC required. S-85 Energy Meters for Distribution Boards Features 7KT PAC0 (Single-Phase) 7KT PAC0 (Three-Phase) Optional KNX /S 85 MODBUS communication modules available for BMS integration Direct measurement upto A & upto 7 V UL-N, CAT IV (for single phase) & V UL-L (for 3 phase) Variant! Dual tariff counter available for Trafo & DG Accuracy ± % for kwh Modular width MW (for Single phase) and MW (for 3 phase) Sealable terminal covers Terms and conditions MPs are subject to revision without prior notice. The company reserves the right to supply goods at its works or godown at its discretion. Export control regulation - retention clause: The fulfillment of the agreement on Siemens part is subject to the provision that this shall not be prevented by implements on the grounds of national and international legal requirements, in particular export control provision. This supercedes all previous Price Lists MPs mentioned in this publication are max. recommended selling prices. Ask your nearest Siemens partners to include you in our mailing list. Note: * MP - Maximum etail Price # MW (Module Width) = 8mm Purchase MOQ for our authorised dealers is in multiples of standard packing, contact Siemens Sales Office for further details 3 Siemens Ltd. Electrical Installation MP Eff. 0--

35 One point contact for your service needs The comprehensive range of services from Siemens is sure to cover the needs of the most varied users. We offer structured services, designed to give you valuable support in every phase during the lifecycle of your Final Distribution Products. Please get in touch with us for details CUSTOME CAE Toll Free No: 0987 / ics.india@siemens.com Customer care One stop support for all service needs: Breakdown service Annual maintenance contracts etrofit solutions Spares For more details please contact: Customer care desk Siemens Ltd. &D Technology Centre Kalwa Works, Thane Belapur oad, Thane Toll free No.: (MTNL/BSNL/Major Mobile operator lines), (BSNL/MTNL) Tel.: Fax: Siemens Ltd. Electrical Installation MP Eff

36 Your partners Sales offices: Ahmedabad 3rd Floor, Prerna Arbour Girish Coldrinks Cross oads Navrangpura Ahmedabad ( : Fax: Baroda Ground Floor, Urja Bhavan Opp.Makarpura ailway Station Maneja Vadodara ( : Fax: Bengaluru st Floor, Jyoti Mahal No. 9, St. Marks oad Bengaluru ( : Fax: Chandigarh SCO 88/9, 3rd Floor, Sector-7 C Chandigarh ( : Fax: Chennai Sathak Centre, No., Mahatma Gandhi oad Chennai ( : Fax: Coimbatore st Floor, Senthil Towers 078, Avinashi oad Coimbatore - 8 ( : Fax: Gurgaon Plot No -78, Tower B Jagatjit Industries Building (JIL) Opposite SBI Academy, Sector-8 Gurgaon - 5 ( : , 30 Hyderabad 5-9-9, th & 5th Floor Laxmi Narasinh Estate Opp. Secretariat oad Saifabad Hyderabad ( : Fax: Jaipur, Park Street Opp. Pink City Petrol Pump M.I.oad Jaipur - 00, ajasthan ( : Fax: Jamshedpur oshan Tower Main oad, Bistupur (nd Floor) Jamshedpur - 8 Kolkata 5th Floor, Infinium Digispace CP - 5, Sector V, Salt Lake Kolkata ( : Fax: Lucknow 8/5, Ashok Marg Opp. Indira Bhawan Lucknow - 00 ( : +9 5, 0 Fax: Mumbai Business Centre- Thane Belapur oad Thane ( : Fax: Nagpur 5th Floor, Land Mark Building Wardha oad, amdas Peth Nagpur - 00 ( : Fax: Pune Tower B/70-705, ICC Trade Tower 3A, Senapati Bapat oad Pune - ( : Fax: Vishakhapatnam nd Floor, -8-7 Lakshmi Narasimha Towers Banu Street, Daba Gardens Visakhapatnam Andhra Pradesh ( : Fax: Territory managers: Agra 3/ PratapPura, Agra - UP Mobile: singh.gurvinder@siemens.com Aurangabad Flat No-03, Building A Disha Sanskruti Silkcity, Paithan oad Aurangabad - (MH) Mobile: Prashant.Joshi@siemens.com Belgaum H.No.73, Narvekar Lane, Shahpur Belgaum , Karnataka Mobile: , anand.gawade@siemens.com Belgaum Flat No 7, nd Floor, Jyotirling Plaza Congress oad, Thilakwadi Belgaum , Karnataka Mobile: prathish.t_m@siemens.com Bharuch Gold B,, Samruddhi esidency Opp. Zadeshwar Bus Stop, Zadeshwar oad Bharuch - 39 Mobile: kalpeshkumar.darji@siemens.com Bhilai Flat No. M-3, ishabh City Prime Potia Kala, Durg (CG) Mobile: pravin.deshbhratar@siemens.com Bhopal Flat No. 0, Sagar Home Phase- Sarvadharma Society, Sector A Nayapura oad Bhopal -, Madhya Pradesh Mobile: prajwal.khapekar@siemens.com Bhubaneswar Plot No. 597, Infront of Fishery Lane Chintamaniswar, Bhubaneswar - 70 Odisha Mobile: sumit.sengupta@siemens.com Bhubaneswar Baramunda Housing Colony L-, Near Saraswati Sishu Mandir Bhubaneswar - 703, Odisha Mobile: samuel.prasad@siemens.com Bhubaneswar House No. 05, Kananvihar, Phase - P. O. Patia, Near Patia Idea Office Bhubaneswar - 73, Odisha Mobile: probir.mukherjee@siemens.com Bhubaneswar Archid oyal Apartment, Flat No. Nageswar Tangi, Bhubaneswar - 70 Odisha Mobile: pm.barik@siemens.com Boisar Flat No. 0, A Wing Mahavir Shrishti Apartments Near Madhur Hotel, Navapur oad Boisar, Thane (W) - Mobile: deashis.biswas@siemens.com Cochin K.G. Oxford Business Centre 3A, Shreekandath d., avipuram Cochin - 8 Mobile: +9 8/, girish.v_nair@siemens.com Cochin K.G. Oxford Business Centre 3A, Shreekandath d., avipuram Cochin - 8 Mobile: nikhil.varghese@siemens.com Dehradun, Dhronpuri, Main lane, G.M.S. oad Deharadun - 0, Uttarakhand Mobile: shashibhushan.prasad@siemens.com Durg Anandvihar Phase-, Plot No. 8 Borsi South, Durg - 900, (CG) Mobile: jitendra.potdar@siemens.com Durgapur C/o Anjan Sadhu 3/3, A.K. Bithi, City Center P.O. - Durgapur - 7 Nearest Landmark - Bidisha esidential Comp. Mobile: saurav.bhowmik@siemens.com Durgapur CD - 9/, M.A.M.C., V.K. Nagar Durgapur - 70 Mobile: partha.mukherjee@siemens.com Goa House No. S-, Classque Appartment Porvorim, Goa - 3 Mobile: jithin.jacob@siemens.com Guwahati Siemens Ltd., House No. Ushanagar, Dispur Supermarket Guwahati, Assam - 70 Mobile: biplab.datta@siemens.com Guwahati Siemens Ltd., House No. Ushanagar, Dispur Supermarket Guwahati, Assam - 70 Mobile: sudipta.garnayak@siemens.com Haridwar P/39, Deep Ganga Complex, Sector 5A Sidcul, Haridwar - 93, Uttrakhand Mobile: kumar.pradeep@siemens.com Hospet amanand esidency, Flat No., st Main Nehru Co-Op Colony, Hospet - 53 Karnataka Mobile: roy.sanjib@siemens.com Hospet #77, Lakshmi Narasimha Nilaya Near Surbhi Kalyana Mantapa Amaravathi, Hospet - 53 Mobile: naveen.sn@siemens.com Hosur No. 78, th Cross, Thirupathi Majestic Vishwanathapuram, Bagalur oad Hosur - 3, Tamil Nadu Mobile: dhayanithi.m@siemens.com Hubli #, Sri Mallikarjuna Nilaya, st Floor Somanagowdara Layout, Bengeri Extension Hubli - 3, Karnataka Mobile: , kr.purushottam@siemens.com Indore Govind Dham, 3 Ahilyapuri Near esidency Club, Indore - (MP) Mobile: aghvendra.bhadhouria@siemens.com Indore Flat No., A Block, Shubh Labh Heights Near Malvi Nagar Chouraha (Nr. Velocity Multiplex), M-9, ing oad Indore -, Madhya Pradesh Mobile: rohit.seth@siemens.com Jalandhar House No. 7, st Floor, Urban Estate Phase I, Jalandar -, Punjab Mobile: sunil.singla@siemens.com Jammu H.No. #A, Sector # Extension Friends Colony, Near Marble Market Trikuta Nagar Extension, Jammu Mobile: chander.parkash@siemens.com Jodhpur D-, Near Sai Baba Mandir, Shankar Nagar Pal oad, Jodhpur Mobile: jain.nitin@siemens.com Kanpur Flat No. 07, Gulmohar Garden Phase I Shastri Nagar, Kanpur - 05, UP Mobile: shagun.gupta@siemens.com Khopoli Flat A, Dutta Krupa Housing Society Upper Khopoli, Near Datta Mandir Khopoli - 3 Mobile: vilas.bhosale@siemens.com Kolhapur S No. 8-, Pinac Prasad, FL No. A-35 New Palace oad, Kolhapur - 00 Mobile: vinay.todkar@siemens.com Kota, Manglayatan Appartments Near Jain Mandir, Bhimganj Mandi Kota - 0 Mobile: avinash.mathur@siemens.com Ludhiana H.No. 9, Lajpat Nagar, Near Bus Stand Ludhiana - 0, Punjab Mobile: rohit.jagga@siemens.com Ludhiana H.No. D-9, New Kitchlu Nagar, Ludhiana Mobile: amitoj.singh@siemens.com Ludhiana -5 Near DAV School Sarabha Nagar Extension, Phase - Pakhowal oad, Ludhiana, Punjab Mobile: padam.sharma@siemens.com Madurai Anirudh Block F-Top 3 Vasudhara Apartment 8, TPK Main oad, Andalpuram Madurai - 003, Tamil Nadu Mobile: sivaprakasam.r@siemens.com Mangalore No. 3, Shreyas Apartment Chandrika Extension, NS Bose oad Bejai, Mangalore Mobile: joseph.arun@siemens.com Meerut A-SF-, Ansal Courtyard, oorkee Bypass Modipuram, Meerut - 00, UP Mobile: singh.vineet@siemens.com Mysore #3, Ground Floor, 8th Cross 3rd Main, st Stage, C Block, J.P. Nagar Mysore Mobile: niranjan.kv@siemens.com Nashik, Nirman Classic Appartment Thatthe Nagar, Behind HDFC Bank Nashik - 05 Mobile: shailesh.bakshi@siemens.com Nashik Flat No. A-3, Brindavan Gardens Kedar Nagar, Shramik Nagar Near Satpur MIDC, Nashik - Mobile: jugal.shah@siemens.com Panipat H.No. 5, First Floor, Near Police Chownki HUDA Housing Board, Sector, Panipat Mobile: Patna Anubhuti Apartment, Flat No. North Anandpuri, West Boring Canal oad Patna Mobile: vikash.prasad@siemens.com Pondicherry No. 3, th Cross Street, Anna Nagar Pondicherry Mobile: lakshmanan.s@siemens.com aipur 03 isabh egency Near Shri Medishine Hospital New ajendra Nagar aipur (CG) - 90 Mobile: raghuraj.bisen@siemens.com ajahmundry Plot No., SV esidency Door No: 77--9/3, Gandhipuram-3 ajahmundry, Dist. East Godavari - 53 Andhra Pradesh Mobile: naga.ganesna@siemens.com ajkot Vrujraj, Chandanpark Society Opp. Gyanganga Vidhyapith Nr. aiya Circle, ajkot , Gujarat Mobile: hiren.raythatha@siemens.com anchi Flat No. A-0, st Floor Sundaram Apartment, Kilburn Colony Hinoo, anchi, Jharkhand - 8 Mobile: shyamal.bhattacharyya@siemens.com enukoot Mobile: umesh.pandey@siemens.com ourkela D/, Gafoor Colony, nd Floor Near LIC office, Udit Nagar ourkela - 790, Odisha Mobile: prakhar.chaturvedi@siemens.com udrapur Flat No., Tower Victoria B Omaxe eviera Ltd. udrapur - 3, Uttarakhand Mobile: ashish.bhatt@siemens.com udrapur Flat No. 0, Tower hone C Omaxe eviera Ltd. udrapur - 3, Uttarakhand Mobile: abhinav.rastogi@siemens.com Salem 3/, Santosh Nagar, PACB Backside Chinnathirupathi, Salem - 8 Mobile: , rubengerald.s@siemens.com Sriperumbudur 3/, Sathyanarayanapuram, Moulivakkam Porur, Chennai - 00 Mobile: venkatesh.janakiraman@siemens.com Surat 3/A, Navrachana Society, Opp. D.K.Park Bhatar oad, Surat Mobile: mitul.kapadia@siemens.com Surat A 0, Stuti Universal, Green City oad Pal-Adajan, Surat , Gujarat Mobile: harshwardhan.mishra@siemens.com Trichy /9-B, th Cross Street, West Extension Vasan Nagar, ettai Vaikkal, Vayalur oad Tirchy - 0 Mobile: Muthu.kumar@siemens.com Udaipur A-, Udai Tower, Hitawala Complex New Flora, Pula Udaipur (ajasthan) - 3, India Mobile: anurag.shah@siemens.com Ujjain Mobile: Bhadauria.amit@siemens.com Vapi Flat No., A Wing, Madhav Gems Nutannagar, Valsad oad, Vapi (East) Valsad Dist Vapi Mobile: pandey.abhishek@siemens.com Vapi Shubham Tower No. 3, C Wing Flat No.008, Chala, Vapi Daman oad Vapi Mobile: s.anand@siemens.com Vijayawada Laxmi Nivas, st Floor Flat No. FF, /3 & / Plot No. 08, Sundarayya Nagar Payakapuram, Vijayawada - 5 Andhra Pradesh Mobile: venkateswar.d@siemens.com Siemens Ltd. Digital Factory Control Products &D Technology Centre Kalwa Works, Thane Belapur oad Thane Fax: lvsgr-mktg.india@siemens.com Order No.: 053 DF-CP-00 (This replaces DI dated 0 Oct 3) Customer Care Toll free no adscs.india@siemens.com Product upgradation is a continuous process. Hence, data in this pricelist is subject to change without prior notice. For the latest information, please get in touch with our Sales Offices.

GST ready. Our commitment is your safe future. Electrical Installations from A to Z (Provisional)

GST ready. Our commitment is your safe future. Electrical Installations from A to Z (Provisional) GST ready Our commitment is your safe future Electrical Installations from A to Z (Provisional) Price List w.e.f. st July, 7 Experience active communication Our Switchgear can now speak and obey your commands

More information

Smart. Easy. Reliable. 7RQ Plug-in Relays.

Smart. Easy. Reliable. 7RQ Plug-in Relays. s Smart. Easy. Reliable. 7RQ Plug-in Relays www.siemens.co.in Smart. Easy. Reliable. Siemens offers a wide range of Plug-in relays to meet your industrial needs. The entire Plug-in Relays range is manufactured

More information

Reliable installations for a safer tomorrow. Electrical Installation A to Z. Answers for infrastructure and cities.

Reliable installations for a safer tomorrow. Electrical Installation A to Z. Answers for infrastructure and cities. s eliable installations for a safer tomorrow. Electrical Installation A to Z Maximum etail Price w.e.f. st November, 2 Answers for infrastructure and cities. 2 Siemens Ltd. Electrical Installation MP Eff.

More information

Smart. Easy. Reliable.

Smart. Easy. Reliable. 3TS Converter duty contactor Smart. Easy. Reliable. www.siemens.co.in Overview: For more than 125 years, Siemens has been developing and manufacturing industrial control products. We offer a wide product

More information

Smart. Easy. Reliable.

Smart. Easy. Reliable. s Smart. Easy. Reliable. Monitoring Relay 7UG0 and Timers 7PV0 Smart. Easy. Reliable. The continuity of electrical power supply is very important especially for the industrial sector where a stoppage of

More information

Betagard Miniature Circuit Breakers and Isolators

Betagard Miniature Circuit Breakers and Isolators s and Isolators www.siemens.co.in and Isolators All round protection guaranteed Betagard 5SL Miniature Circuit Breakers Betagard 5SY Circuit Breakers Betagard 5SP Miniature Circuit Breakers Betagard 5TL

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

Modular design for all applications

Modular design for all applications SIRIUS 3SE5 Position Switches Modular design for all applications www.siemens.co.in Introduction: Accurate and dependable: SIRIUS detecting devices stand guard There is a lot of information in the field.

More information

Lightning and Surge Arresters

Lightning and Surge Arresters Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement

More information

Smart. Easy. Reliable. Automatic Power Factor Controller Relay 7UG05 for optimized power need.

Smart. Easy. Reliable. Automatic Power Factor Controller Relay 7UG05 for optimized power need. Smart. Easy. Reliable. Automatic Power Factor Controller Relay 7UG05 for optimized power need. www.siemens.co.in 7UG05 Automatic power factor correction relay Controls the required Power factor Manage

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

Appendix 08: Details of Location under Each Category

Appendix 08: Details of Location under Each Category Appendix 08: Details of Location under Each Category Dated: Sr. No. A Bank Location CATEGORY - A Type of 1 Hyderabad - DR DR Site Telangana 2 Mumbai - DC DC Site 3 Mumbai- DC 4 Bangalore-

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

Soft starter- ASAB 1

Soft starter- ASAB 1 Soft starter- ASAB 1 ASAB-Series Soft starter Soft start/stop static starters for three-phase asynchronous motors. The ASAB is an advanced digital soft start solution for motors from 7 kw to 800 kw. ASAB

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

TP&N DISTRIBUTION BOARD TYPE B RANGE

TP&N DISTRIBUTION BOARD TYPE B RANGE GROUP Now included in the range: Extension Boxes Metering Kits Surge Suppression and more! TP&N DISTRIBUTION BOARD TYPE B RANGE A comprehensive distribution board range for modern commercial & industrial

More information

DESIGN YOUR WORLD WITH YOUNG ENERGY

DESIGN YOUR WORLD WITH YOUNG ENERGY DESIGN YOUR WORLD WITH YOUNG ENERGY S w i tc h es & Plat e s List Price w.e.f. 23rd Oct. 2017 STANDARD SWITCHES 2 STANDARD SWITCHES 3 Switches & Plates SWITCH MODULE 10AX One way switch ASZSXXW101 8536

More information

NEW Titan II A & B Distribution Boards

NEW Titan II A & B Distribution Boards A Type Board Specification: Powder Coated Epoxy Resin Finish RAL 7035 Designed and built in the UK to BS EN 60439 Maximum busbar rating 125A Degree of protection IP3X to BS EN 60529 Blank gland plates

More information

Miniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :

Miniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data : Miniature Circuit Breakers reliable solutions for protection of installations against over-current phenomenon Advantages for you : Bi-connect terminals for simultaneous termination of bus bar & wires Unique

More information

Dorman Smith Loadbank 125 MCCB Panel Boards

Dorman Smith Loadbank 125 MCCB Panel Boards Dorman Smith Loadbank 125 MCCB Panel Boards Section 3 MCCB Panel Boards Loadbank 125 Range (250A and 400A Ratings) Overview Key Features ASTA certified busbars with a short circuit rating of 25kA for 1

More information

5SL Miniature Circuit Breakers

5SL Miniature Circuit Breakers 5SL Miniature Circuit Breakers BETA Low-Voltage Circuit Protection The new 5SL miniature circuit breaker is intended for use up to ka. The devices have the system features characteristic of all Siemens

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2013 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2014 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 combination surge arresters, type 1 / type

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches NEW P. 4 RX3 MCBs 63 A 4500 & 6000 prong type busbar MCBs, RCDs, add-on modules & accessories P. 9 DX3 RCBOs 63 A 6000 / 10 ka AC, A & Hpi type prong & fork type busbar P. 16 DX3 MCBs 63 A 50 ka mcbs,

More information

US Catalog July 2016 SMISSLINE TP

US Catalog July 2016 SMISSLINE TP US Catalog July 2016 SMISSLINE TP SMISSLINE TP modular bus system Table of contents Description 2 Building a SMISSLINE TP assembly for UL 489 and UL 508 based solutions Overview and ordering information

More information

3RV1 Circuit-Breakers

3RV1 Circuit-Breakers SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge arresters, type

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 201 /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 + type 2 /7 5SD7 combination surge arresters, type 1 / type 2 /9 5SD7 surge arresters, type

More information

125A SPN, type A distribution boards Incoming devices Meterpack assemblies Surge protection devices... 34

125A SPN, type A distribution boards Incoming devices Meterpack assemblies Surge protection devices... 34 Memshield 3 MCB distribution boards and enclosures 2 Eaton s Memshield 3 MCB distribution boards have evolved through an intimate knowledge and feedback from electrical contractors, consulting engineers

More information

ALPHA SIMBOX Small Distribution Boards

ALPHA SIMBOX Small Distribution Boards ALPHA SIMBOX Small Distribution Boards /2 Introduction /3 Introduction /4 Flush-mounting and hollow-wall distribution boards /5 Surface-mounting and hood-type distribution boards /6 Accessories /7 Dimensional

More information

Miniature circuit breakers for all applications

Miniature circuit breakers for all applications Miniature circuit breakers for all applications BETA Low-Voltage Circuit Protection Answers for infrastructure. BETA Low-Voltage Circuit Protection: Circuits under Control, Wherever, Whenever. Whether

More information

The right solution for every home

The right solution for every home Domae Household switchboards The right solution for every home Household guide 2002 Building a New Electric World. Household switchboards Domae The right solution for every home Household guide 2002 Building

More information

3SB5 Datasheet 3SB5. Indicating lamps and push buttons.

3SB5 Datasheet 3SB5. Indicating lamps and push buttons. 3SB5 Datasheet 3SB5 Indicating lamps and push buttons www.siemens.co.in Control at your finger tips Index Device Types Pg 03 Benefits Pg 04 Overview Pg 05 Selection and ordering data Pg 06 Technical Data

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP SIMBOX 63 /4 Introduction /5 Flush mounting distribution boards /6 Hollow-wall distribution boards /7 Surface mounting distribution boards /7 Hood-type

More information

Video Door Phone Collection 2017

Video Door Phone Collection 2017 Door Phone Collection 2017 Safe Home with Crabtree Door Phone Add Security to your lifestyle Crabtree VDP products are designed and developed to the highest quality standards for individual residential

More information

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) 030 23 030 28 039 21 039 33 039 34 Type 1 voltage surge protectors (V.S.P.) for main

More information

Inspired By Nature List Price w.e.f. 1st July 2017

Inspired By Nature List Price w.e.f. 1st July 2017 Inspired By Nature Inspired by genuine elements of nature, Amare has been aesthetically designed to complement the latest interior trends. These masterfully crafted wooden, glass and metal switch plates

More information

Energy Saving HRC Fuse-Links

Energy Saving HRC Fuse-Links Energy Saving HRC Fuse-Links Blade Type HN 3 A - 800 A Cylindrical Type HF A - 3 A L&T, India's largest manufacturer of low tension switchgear, offers the new generation of low watt loss HRC fuse-links

More information

Surge Protective Device

Surge Protective Device SURGE PROTECTIVE DEVICE Surge Protective Device 20 R 320 Type Max. discharge current Imax/Iimp (ka) Number of poles (P) R: with alarm auxiliary contact Blank: without alarm auxiliary contact Max. continuous

More information

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional

More information

US CATALOG SMISSLINE TP

US CATALOG SMISSLINE TP US CATALOG SMISSLINE TP 2 SMISSLINE TP US CATALOG SMISSLINE TP US CATALOG 3 Table of contents 004 Description 005 012 for UL 508 and UL 489 based solutions Overview and ordering information 013 014 for

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

QUICK REFERENCE PRICE GUIDE JUNE 2016

QUICK REFERENCE PRICE GUIDE JUNE 2016 QUICK REFERENCE PRICE GUIDE JUNE 2016 OUR CUSTOMER CARE COMMITMENTS Quality is Guaranteed All products supplied from this Quick Price Guide carry a guarantee against defects in materials and workmanship

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

CALL LOGGING PROCESS

CALL LOGGING PROCESS CALL LOGGING PROCESS 1. TO REGISTER A COMPLAINT, FIRST YOU NEED TO REGISTER YOUR PRODUCT ON VIVITEK WEB SITE. BELOW ARE THE STEPS TO REGISTER YOUR PRODUCT ON VIVTEK WEB SITE. 2. LOG ON TO WWW.VIVITEK.IN

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

Ahmedabad Amritsar Bangalore Bathinda

Ahmedabad Amritsar Bangalore Bathinda Ahmedabad 3rd Floor, Navneet Plaza, Near Municipal Market, CG RoadAhmedabad 380001 Guj arat Tel: +91 079 400 491 00-104 Email:ahmedabad@canamgroup.com Amritsar SCO-37, 3rd Floor, District Shopping Complex,

More information

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE

More information

Surge Protection Devices Ex9UE2

Surge Protection Devices Ex9UE2 Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,

More information

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka) MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016 Low voltage Acti 9 the efficiency you deserve Catalogue 03/2016 schneider-electric.com 1 and 2 LV surge s 1 and 2 LV surge s (cont.) The 1 range of surge s meets the normative withstand capability of wave

More information

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...

More information

3VA molded case circuit breaker up to 1600A. Frei verwendbar Siemens AG 2018

3VA molded case circuit breaker up to 1600A. Frei verwendbar Siemens AG 2018 3VA molded case circuit breaker up to 1600A Unrestricted Siemens AG 2018 siemens.com/3va 3VA molded case circuit breaker New 3VA13/14 with TMTU (Thermal Magnetic Trip Unit) New 3VA27 with ETU (ElectronicTrip

More information

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009 Siemens AG 9 BETA Protecting SR Busbar Systems /2 Product overview /3 Distribution board components /9 Built-in components /17 Mounting components Siemens ET B1 10/9 BETA Protecting SR Busbar Systems Siemens

More information

Surge Protection Devices and Surge Protection Kit

Surge Protection Devices and Surge Protection Kit Surge and Surge Kit SPD s protect electrical and electronic equipment against transients, originating from lightning, switching of transformers, lighting and motors 3. Main protection - class 3 To cut-down

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide

More information

SENTRON 3VL Molded Case Circuit Breakers

SENTRON 3VL Molded Case Circuit Breakers Siemens AG SENTRON VL Molded Case Circuit Breakers Switching, Protection, Measuring and Monitoring Devices For the operating range from A to 00 A, the molded case circuit breaker ensures the optimum overload

More information

Products and solutions for generating sets

Products and solutions for generating sets Products and solutions for generating sets www.lovatoelectric.com Tra dition and Innovation Since 1922 The first LOVATO Electric headquarters founded in Bergamo (Italy) in 1922: the starting point of the

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories / SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in

More information

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

Technical features OVR Surge Protective Devices Type 1 & Type 1+2 Type 1 & Type 1+2 TECHNICAL FEATURES Technology Type 1 OVR T1 2 TS Triggered spark-gap Electrical features Standard IEC 61643-1 / EN 61643-11 Type / test class 1 / I Poles 1P - 1P -, 2P 2L 3P 3L 4P 4L

More information

GLOBAL Compliance with worldwide standards

GLOBAL Compliance with worldwide standards GLOBAL Compliance with worldwide standards ASTA EN CSA TUV GB CCC JIS UL TPC IEC SABS CCS LR GL DNV ABS BV NK CONTENTS AIR CIRCUIT BREAKER MOULDED CASE CIRCUIT BREAKER FINAL DISTRIBUTION PRODUCTS CONTROLGEAR

More information

RB60 RANGE. Miniature circuit breakers

RB60 RANGE. Miniature circuit breakers RB60 RANGE Miniature circuit breakers POWER 2015 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection

More information

194E FA 32 E P11 P11 6

194E FA 32 E P11 P11 6 Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure

More information

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip Product Managers and dedicated Business Development Managers are available to assist with all your enquiries. Technical presentations (Forms of Separation, Discrimination etc) available Site response capability

More information

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities. KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA

More information

Overvoltage Protection for low-voltage supplies

Overvoltage Protection for low-voltage supplies Class I Overvoltage Protection.2 -.3 with sparkover gaps.4 -.9 with high-power varistors.10 -.11 Overvoltage Protection, combination arrester.12 -.15 Class II Overvoltage Protection with varistors.16 -.25

More information

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany Lightning and Surge Protection of Photovoltaic Installations 1 Lightning and Surge Protection for PV Installations 2 Safeguard from Risks Ups, that was the insurance policy of my house!! 3 Why Lightning

More information

L.V. Systems & Solutions

L.V. Systems & Solutions GE Energy Industrial Solutions L.V. Systems & Solutions Residential Components & Distribution Boards Home & Building Automation Industrial Breakers General Purpose Enclosures System Enclosures Control

More information

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS. 3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA

More information

Technical Data Sheet Medium Current Power Surge Filters

Technical Data Sheet Medium Current Power Surge Filters Technologies Technical Data Sheet Medium Current Power Surge Filters Features High performance surge protector for an operating voltage of 0-220Vac Designed to withstand fault and over-voltage conditions

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

LPI SG + SS480 Spark Gap Surge Filters

LPI SG + SS480 Spark Gap Surge Filters LPI SG + Spark Gap Surge Filters Features High performance surge protector for an operating voltage of 220-277Vac Encapsulated spark gap and technology capable of operation under fault /overvoltage conditions

More information

The art of simplicity. sentron

The art of simplicity. sentron The art of simplicity Data Sheet sentron 3WT s Sentron 3WT The Art of Simplicity. During the last decade, with the introduction of 3WN and 3WL Circuit Breakers, Siemens introduced a new perspective in

More information

Lightning and Surge Arresters

Lightning and Surge Arresters / Lightning and Surge Arresters Product overview /3 Introduction /6 Lightning arresters, requirement category I (B) /8 Combination arresters, requirement category I (B) and II (C) /0 Single-pole surge

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

LOADSTAR MCBs AND DISTRIBUTION BOARDS

LOADSTAR MCBs AND DISTRIBUTION BOARDS MCBS AND DISTRIBUTION BOARDS Devices 6kA and 10kA Ranges 6A to 63A Single, Double and Triple Pole Type B, C & D Single and Double module RCBOs 35mm 2 Cable Terminals BS EN 60898 System 125A and 250A TP

More information

SENTRON SIVACON ALPHA

SENTRON SIVACON ALPHA SENTRON SIVACON ALPHA Low-Voltage Power Distribution and Electrical Installation Technology Catalog Extract LV 10 Edition 10/2018 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution

More information

ASCO SERIES 230 Automatic Transfer Switch

ASCO SERIES 230 Automatic Transfer Switch ASCO SERIES 230 Automatic Transfer Switch The Recognized Leader in Power Transfer Switch Technology Offers the Most Advanced Transfer Switches in the World. Application Product Overview The Series 230

More information

ELECTRONIC MOTOR PROTECTION RELAYS

ELECTRONIC MOTOR PROTECTION RELAYS ELECTRONIC MOTOR PROTECTION RELAYS ELECTRONIC MOTOR PROTECTION RELAYS Electronic Multifuctional Motor Protection Relays are designed to monitor two/three phase motor currents by integral/external current

More information

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester These modular distribution panel protectors for three phase power systems are designed to prevent damage to electrical distribution systems from mainsborne transient voltages which can occur as the result

More information

CANARA BANK NRI CELL, CIRCLE OFFICE 1ST FLOOR, RED CROSS BHAVAN SACHIVALAYA MARG BHUBANESWAR : ODISHA, INDIA E MAIL ID:

CANARA BANK NRI CELL, CIRCLE OFFICE 1ST FLOOR, RED CROSS BHAVAN SACHIVALAYA MARG BHUBANESWAR : ODISHA, INDIA E MAIL ID: CONTACT DETAILS For any information/clarification/grievance on matters connected with NRIs, please contact our BRANCHES spread across the country: NRIs may also contact the following NRI Cells/Offices.

More information

Supplemental Protectors

Supplemental Protectors compact S200 Series Miniature circuit breakers S200, S200P, S200U, S200UP Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The S2 devices are

More information

ßCompliant with Amendment 3 ßBSEN for easy cabling. accommodate RCBOs. meeting current standards

ßCompliant with Amendment 3 ßBSEN for easy cabling. accommodate RCBOs. meeting current standards CHINT EUROPE (UK) LTD Chint Metal Consumer Units ßCompliant with Amendment 3 of BS 7671 : 2008 Regulation 421.1.201 ßBSEN 61439-3 3 to 36 Ways are Standard Specials to Customer Requirements ß 1mm steel

More information

workstations from Featherlite

workstations from Featherlite workstations from Featherlite Featherlite : Featherlite group, founded in 1965, is one of the leading furniture manufacturing & marketing organizations in India, providing complete office furniture solutions

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

Isobar 4c distribution boards and devices Selection guide

Isobar 4c distribution boards and devices Selection guide Isobar 4c distribution boards and devices Selection guide Isobar 4c Type A distribution boards Standard 125A distribution boards excluding incomer SP outgoing 6 MGAN6 9 MGAN9 12 MGAN12 15 MGAN15 23 MGAN23

More information

sirius Switching. Protecting. Starting. SIRIUS Product Overview

sirius Switching. Protecting. Starting. SIRIUS Product Overview sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

Safety. Detection. Control. MAGNUS RFID ENG - REV

Safety. Detection. Control. MAGNUS RFID ENG - REV 03 2017 1 Next generation RFID safety sensor 03 2017 2 03 2017 3 Next generation sensors for machine safety RFID safety sensors PL e, SIL 3 The application of Magnus RFID sensors can be extremely wide

More information

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................

More information

Thermal-Magnetic Circuit Breaker 4220-T...

Thermal-Magnetic Circuit Breaker 4220-T... Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With

More information