1 s and Isolators

2 and Isolators All round protection guaranteed Betagard 5SL Miniature Circuit Breakers Betagard 5SY Circuit Breakers Betagard 5SP Miniature Circuit Breakers Betagard 5TL Isolators 0 Accessories

3 and Isolators Type 5SL Type 5SL Overview As a culture Siemens has always endeavoured to introduce innovative products worldwide. The Electrical Installation R&D team has now raised the bar with the introduction of Betagard 5SL Miniature Circuit Breaker. Manufactured and designed at the Siemens Aurangabad facility, Betagard 5SL Inspiring Safety, sets a new benchmark for protection. Loaded with numerous features, Betagard 5SL is the only patented MCB with a unique SLR (Slide Latch-Release) feature for tool free removal of MCB from DIN rail. It also allows single MCB removal from a bus mounted assembly of MCBs. Betagard 5SL MCB is ergonomically designed and allows user-friendly switching. ON-OFF Status is easily recognizable thanks to the color coded switching position indicator on its attractive grey lever. With highly effective touch protection against accidental contact, Betagard 5SL range is available in current rating upto A in B and C characteristics. Features and Benefits IS/IEC 09 - BIS approval for ISI marking as per latest IS/IEC 09:00 for assured quality and protection Green product Recyclable, low watt loss, free from hazardous material like CFC and silicon (ROHS) With SLR MCB with patented unique SLR (Slide Latch-Release) feature for tool free removal from DIN rail. It also allows individual MCBs to be removed from bus mounted assembly

4 and Isolators Type 5SL Type 5SL Ergonomically designed, with a user friendly lever for effortless switching To highlight exact switching position, easily recognizable color coded ON-OFF is embedded on the attractive grey lever Uniquely designed square terminal to accommodate wire up to 5 Sqmm Highly effective touch protection against accidental contact Enables firm mounting of Bus bar together with wire and front access of wires for safer installation Terminals can accommodate wires of same cross section (Solid up to X 0 mm and finely stranded with end sleeve up to X mm ) without twisting wire strands facilitates easier and safe wiring Side mounting accessories like auxiliary switches and fault signaling contacts available for special applications Lever locking device with maximum mm shackle

5 and Isolators Type 5SL Type 5SL Application B Characterstics B Characteristic MCBs react quickly to short circuit, and are set to trip when the current passing through them is between to 5 times the normal full load current. They are suitable for protecting incandescent lighting and socketoutlet circuits in domestic and commercial environments, where there is little risk of surges that could cause the MCB to trip. C Characteristics C characteristics MCBs are used for protection of electrical circuits in general and are most widely used because of its suitability for practically all electrical circuits, cable and line protection. They are capable of protecting the majority of inductive and capacitive loads including most motor and fluorescent lighting loads. This characteristic allows applying loads having high peak currents without requiring the MCB to be oversized. In fact, thanks to this characteristic, it is possible to apply loads with peak currents up to 5 times In, (rated current) and can hence be used to best advantage for handling higher inrush currents e.g. lamps, motors, etc. Under C characteristics, the magnetic operating limits (for short-circuit operations) are between 5 and 0 times the rated current (In) of MCB. For example the instantaneous mechanism of a 0A MCB will operate between A and 00A in an overcurrent situation. The thermal operating limits (for overload operation) are between. and.5 of the rated current (In) of the MCB. Effect of temperature on tripping characteristics: Betagard MCBs are designed to meet the requirements of IS / IEC 09 for tripping performance at ambient temperature 0 C. At other operating temperature the overload tripping band is modified by approximately 5% per 0 Celcius temperature difference, which increases for lower and decreases for higher temperatures than 0 C. Characteristic curves Tripping Characteristics as per IS/IEC 09-:00 Tripping time Minutes Seconds I_5 Tripping time Minutes Seconds I_ Multiple of rated current Multiple of rated current 0 Tripping characteristic B MCBs with this tripping characteristic are designed for universal use in socket outlet and lighting circuits. Tripping characteristic C In lamp and motor circuits with higher starting currents, MCBs with tripping characteristic C are generally used. 5

6 and Isolators Type 5SL Effect of Higher Operating Voltages Betagard MCB is designed to operate at 0/5V, Hz. However the device can operate at 0V, /0 Hz with a reduction in breaking capacity of %. DC Operation Single pole MCBs can be used up to 0V DC and double pole up to 0V DC. However, they should not be used below V DC. Though the thermal operation is delayed but this is negligible. The instantaneous tripping characteristic must be increased by 0% (e.g. a Type C MCB has a magnetic tripping characteristic between 5 and 0 times the rated current. This magnetic tripping characteristic would therefore become between 7 and times the rated current. Temperature correction factor for 5SL MCBs Correction factor Rating [A] B Pole,0,0,0,00 0,90 0, Ambient temperatur [ C] Curve Curve Curve 0, valid curve for correction factor / / C / / Temperature correction factor for 5SL MCBs Frequency Variation Type 5SL MCBs may be used up to their normal voltage rating on 00Hz supplies; however the magnetic tripping characteristic must be increased by 0% (e.g. Type C MCB with magnetic characteristics between 5 and 0 times the rated current would become between.5 and times rated current. Selectivity of miniature circuit-breakers/fuses Generally, distribution networks are configured as radial networks. An overcurrent device must be provided at each reduction of the conductor cross section. This results in a cascade graded according to the rated current, which should, where possible, provide selectivity. Selectivity means, that in the event of a fault, only the protective device in the vicinity of the fault trips. Thus, parallel current paths can continue to provide the necessary power. For MCBs with upstream fuses, the selectivity limit essentially depends on the current limits and tripping characteristics of the MCB as well as on the pre-arcing I²t value of the fuse. Therefore, MCBs with different characteristics and rated breaking capacities also have different selectivity limits. The subsequent tables show the currents up to which selectivity is provided between MCBs and upstream fuses according to DIN VDE 0 Part. The values specified in ka are limit values which have been determined under unfavourable test conditions. In practice, better values can be obtained, depending on the type of the upstream fuse. In the event of a short circuit, when using the 5SL, MCBs and fuses according to DIN VDE 0 Part, Selectivity is provided up to the indicated values in ka. Internal power loss P v of the miniature circuit breaker 5SL (Data per pole with I n ) Ratings Watt loss as per Watt loss as per testing (W) IEC 09- (W) 5SL - B 5SL - C 5SL - C Correction factor Ambient Temperature( C) st curve nd curve rd curve Rating [A] 0, Pole valid curve for correction factor / C /

7 and Isolators Type 5SL Type 5SL Tripping characteristics Tripping characteristics at an ambient temperature of 0 C Tripping characteristic Standards Thermal trips Test currents: Electromagnetic trips Test currents: Limiting test current I Minimum test current I Tripping time I n A t Hold I Latest tripping instant I 5 Tripping time t.5 I n B IS/IEC 09-,. I n > h < h I n 0. s 5 I n < 0. s C IS/IEC 09-,. I n.5 I n > h < h 5 I n 0. s 0 I n < 0. s Technical Specifications Betagard 5SL Standards IS/IEC 09- :00 Tripping characteristic Number of poles B, C P, P, P, P Rated voltage V AC 0/5 Operational voltage min. max. max. V AC/DC V DC/pole V AC 0 ) 0 Rated breaking capacity acc. to IS/IEC 09- ka AC 7.5 Current Rating Ampere B Curve: - C Curve: Insulation coordination Rated insulation voltage V AC V DC/pole /0 0 Degree of Pollution for overvoltage category III Touch Protection Acc to EN 7 Yes Line load reversibility Degree of protection CFC and silicone-free Yes IP0 Yes Terminal tightening torque, recommended Nm.5... Conductor cross-sections Solid and stranded Finely stranded with end sleeve, max. Mounting position Average Service life (with rated load) mm mm Any 0000 actuations Ambient temperature C , occasionally +55, max. 95% humidity, storage temperature: ) The operational voltage 0 V DC/pole takes into account a battery charging voltage with peak value of 7 V Dimensional drawings 5SL/5SL P P P 5 P

8 and Isolators Type 5SL Type 5SL Selection and ordering data 70A I n A Mounting width MW ) Characteristic B Order No. Characteristic C Order No. Std. Pkg. (Nos.) P, 0/5 V AC SL0RC 5SL0RC 5SLRC 5SL0RC 5SL5RC 5SLRC 5SL0RC 5SLRC 5SLRC 5SL057RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL7RC 5SL7RC 5SL07RC 5SL57RC 5SL7RC 5SL07RC 5SL7RC 5SL7RC / / / / / / / / / / / / / / / / P, 5 V AC SL0RC 5SL0RC 5SLRC 5SL0RC 5SL5RC 5SLRC 5SL0RC 5SLRC 5SLRC 5SL057RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL7RC 5SL7RC 5SL07RC 5SL57RC 5SL7RC 5SL07RC 5SL7RC 5SL7RC / / / / / / / / / / / / / / / / P, 5 V AC SL0RC 5SL0RC 5SLRC 5SL0RC 5SL5RC 5SLRC 5SL0RC 5SLRC 5SLRC 5SL057RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL7RC 5SL07RC 5SL57RC 5SL7RC 5SL07RC 5SL7RC 5SL7RC / / / / / / / / / / / / / P, 5 V AC SL0RC 5SL0RC 5SLRC 5SL0RC 5SL5RC 5SLRC 5SL0RC 5SLRC 5SLRC 5SL057RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL7RC 5SL07RC 5SL57RC 5SL7RC 5SL07RC 5SL7RC 5SL7RC / / / / / / / / / / / / / ) MW (modular width) = mm.

9 and Isolators Type 5SL Type 5SL Overview General Betagard 5SL range of MCBs have rated breaking capacity of 0kA. They comply to the latest national and international standards, with current ratings from 0.5A to A. Short circuit operation At high values of overcurrent (i.e. short circuit current) a plunger in the solenoid is moved with sufficient force to physically separate the contacts. The greater the short circuit current, the greater the force with which the plunger is moved and faster the circuit is disconnected. A secondary action will ensure that the circuit breaker mechanism is tripped and prevents the contacts from reclosing. It is the rapid speed with which the contacts are forced apart coupled with other features of MCBs, which provides the Current limiting capability and safe interruption up to 0,000A. The rapid speed at which the contacts are parted prevents the fault current from reaching its prospective value. The arc drawn between the contacts is moved by magnetic forces into the multiple plate arc chamber where the arc is split, rapidly cooled and extinguished. The total operating time of the MCB is between to 5 milliseconds. The energy let through (I²t) of the device is kept to a minimum thus offering a very high degree of protection. Current limiting class 5SL type MCBs significantly limit the let-through current (when a fault occurs) due to the ultra fast contact separation and the quick quenching of the emergency arc in the chamber. Thus, generally, they fall below the permissible limiting I²t values of the energy limiting class, specified in DIN VDE 0 Part II by %. This guarantees excellent discrimination with the upstream protective devices and reduces the thermal stress on the downstream connected equipments. Chart indicates the let through energy values of 0kA, A MCB according to EN 09. This MCB (Amps) will allow only % of,000 (A²S) let-through energy thereby reducing thermal stress to bare minimum value on the downstream equipment. As these MCBs meet the requirements of current limiting class, according to EN 09 without difficulty, they are therefore marked with symbol 0000 Rated Current Current Limiting Class according to EN 09 A Permissible let-through I²t (A²S) No limit,90,000,000 Technical Specifications Betagard 5SL Standards IS/IEC 09- :00 Tripping characteristic C Number of poles P, P, P, P Rated voltage V AC 0/5 Operational voltage min. max. max. V AC/DC V DC/pole V AC 0 ) 0 Rated breaking capacity acc. to IS/IEC 09- ka AC 0 Current Rating Ampheres Insulation coordination Rated insulation voltage V AC V DC/pole /5 0 Degree of Pollution for overvoltage category III Touch Protection Acc to EN 7 Yes Line load reversibility Yes Degree of protection IP0 CFC and silicone-free Yes Terminal tightening torque, recommended Nm.5... Conductor cross-sections Solid and stranded Finely stranded with end sleeve, max. Mounting position Average Service life (with rated load) mm mm Any 0000 actuations Ambient temperature C , occasionally +55, max. 95% humidity, storage temperature: ) The operational voltage 0 V DC/pole takes into account a battery charging voltage with peak value of 7 V 9

10 and Isolators Type 5SL Type 5SL Selection and ordering data 0000A Rated current I n (A) MW ( MW= mm) Reference No. Characteristics C Std. Pkg. (Nos) -Pole, 0/5 V AC Pole, 5 V AC Pole, 5 V AC Pole, 5 V AC SL057RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL7RC 5SL7RC 5SL07RC 5SL57RC 5SL7RC 5SL07RC 5SL7RC 5SL7RC 5SL057RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL7RC 5SL7RC 5SL07RC 5SL57RC 5SL7RC 5SL07RC 5SL7RC 5SL7RC 5SL057RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL7RC 5SL7RC 5SL07RC 5SL57RC 5SL7RC 5SL07RC 5SL7RC 5SL7RC 5SL057RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL07RC 5SL7RC 5SL7RC 5SL07RC 5SL57RC 5SL7RC 5SL07RC 5SL7RC 5SL7RC / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 0

11 and Isolators Betagard Circuit Breakers Type 5SY Betagard Circuit Breakers Type 5SY Overview MCB are widely used in infrastructure, industry application, provide protection for circuit and device. Products are mainly used for trip and isolation. For industry and some engineering projects, the 5SY CBs can be combined with additional accessories. Products highlight. Optional top or bottom infeed as the terminals are identical. Duplicate terminal clamps allow conductors with different cross-sections (cross-section combinations upon request) to be fitted.. Bigger space for terminal connection. Easier and faster removement from busbar.. Fast operation will save time for installation. Clear and visible conductor connection in front of the rear busbar facilitates controls The 5SY circuit breakers are ideal for the quick and easy mounting of auxiliary switches and fault signal contacts without the need for tools. The infeed can be implemented either from the top or the bottom. Additional terminals with lateral cable entry facilitate mounting when using large conductor cross-sections.

12 and Isolators Betagard Circuit Breakers Type 5SY7 Betagard Circuit Breakers Type 5SY7 Technical Specifications Betagard 5SY7 Standards IEC/EN 097- Rated voltage Un V AC 0/00 Tripping characteristics Rated current In A 0.5 to Operational voltage According to IEC09-/ IEC097- Breaking capacity Icn according to IEC09- Icu according to IEC097- Min Max Max VAC/DC/pole VDC/pole VAC ka AC ka AC D 7 / * Insulation coordination VAC /0 Overvoltage category Pollution degree Touch protection According to IEC7 Yes Main switch characteristics According to EN00 Yes III Handle end position, sealable Degree of protection According to EN059 Directly installed Put into distribution box Conductor cross section Solid and stranded Finely stranded, with end sleeve mm mm Yes IP0 IP Installation Mains connection AC DC Mounting position Any Any Any Mechnical service life 0000 Electrical service life 0000 Storage temperature C Ambient temperature C , max 95% humidity Shock IEC007 m/s at 0ms half-sine Resistance to vibration IEC00 m/s, when 5...Hz, at 5Hz Dimensional drawings P P P 5 P 7 70 * 5SY7 s breaking capacity according to different current D0.~A ka D~A 0kA D~5A 5kA DA 0kA D0~A 5kA

13 and Isolators Betagard Circuit Breakers Type 5SY7 Betagard Circuit Breakers Type 5SY7 Selection and ordering data Rated current 00A I n (A) P, 0/00V AC P, 00V AC P, 00V AC P, 00V AC MW Reference No ( MW= mm) 5SY705CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY7CC 5SY7CC 5SY70CC 5SY75CC 5SY7CC 5SY70CC 5SY7CC 5SY7CC 5SY705CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY7CC 5SY7CC 5SY70CC 5SY75CC 5SY7CC 5SY70CC 5SY7CC 5SY7CC 5SY705CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY7CC 5SY7CC 5SY70CC 5SY75CC 5SY7CC 5SY70CC 5SY7CC 5SY7CC 5SY705CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY70CC 5SY7CC 5SY7CC 5SY70CC 5SY75CC 5SY7CC 5SY70CC 5SY7CC 5SY7CC Std. Pkg. (Nos) / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /

14 and Isolators Betagard DC Circuit Breakers Type 5SY5 Betagard DC Circuit Breakers Type 5SY5 Overview In alternating current circuits, arc quenching is assisted by the fact that current passes through zero, and that the current can only continue to flow if the arc is re-stuck across the open contacts during the following half wave. Direct current does not provide such assistance. In this case, a high arc voltage must be developed in order to stop the flow of the DC current. Therefore, the DC switching capacity depends on the arc quenching method employed by the switching device, on the network voltage & on the inductive reactance of the circuit. In order to address DC network protection, Siemens offers 5SY5 series DC circuit breakers from 0.5A to A in Single pole & Double pole version. When using DC CBs in DC networks, care must be taken to ensure the contact polarity of the connections. CBs for DC and AC/DC Applications In DC networks up to 0 V, existing 5SL MCBs are suitable for single-pole and double-pole application. For higher voltages, the versions 5SY5 are required. Contrary to the other product range, the arcing chamber area of 5SY5 is equipped with an additional permanent magnet to support the positive quenching of the arc. For this reason, the polarity of the DC circuit breaker is clearly marked and must be observed when connecting the cables and conductors. Technical Specifications Betagard 5SY5 Standards IEC/EN 097- Rated voltage Un V DC 0/0 Rated current In A 0.5 to Operational voltage According to IEC09-/ IEC097- Min Max Max VAC/DC/pole VDC/pole VAC Breaking capacity Icn according to IEC09- Icu according to IEC097- ka AC ka AC ka DC Insulation coordination VAC VDC/pole /0 Overvoltage category III Pollution degree Touch protection According to IEC7 Yes Main switch characteristics According to EN00 Yes Handle end position, sealable Degree of protection According to EN059 Directly installed Put into distribution box Conductor cross section Solid and stranded Finely stranded, with end sleeve mm mm Yes IP0 IP Installation Mains connection AC DC Mounting position Specified Connections (refer connection diagram) Any Mechnical service life 0000 Electrical service life 0000 Storage temperature C Ambient temperature C , max 95% humidity Shock IEC007 m/s at 0ms half-sine Resistance to vibration IEC00 m/s, when 5...Hz, at 5Hz

15 and Isolators Betagard DC Circuit Breakers Type 5SY5 Betagard DC Circuit Breakers Type 5SY5 Selection and ordering data 0000A P, 0V DC P, 0V DC Rated current I n (A) MW ( MW= mm) Reference No 5SY57CC 5SY7CC 5SY7CC 5SY7CC 5SY7CC 5SY7CC 5SY7CC 5SY7CC 5SY57CC 5SY57CC 5SY7CC 5SY557CC 5SY57CC 5SY7CC 5SY57CC 5SY57CC 5SY57CC 5SY7CC 5SY7CC 5SY7CC 5SY7CC 5SY7CC 5SY7CC 5SY7CC 5SY57CC 5SY57CC 5SY7CC 5SY557CC 5SY57CC 5SY7CC 5SY57CC 5SY57CC Std. Pkg. (Nos) / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / Connection Diagram P P P P Up line Up line Down line Up line Down line Up line Down line load Remark: ) L+ positive of power; L- negative of power Dimensions Symbols 5 90 P P 70 P P 5

16 and Isolators Type 5SP Type 5SP Overview General Siemens Betagard range of MCBs type 5SP offer high short circuit breaking capacity equal to 0kA as per IS/IEC 09 - : 00. These MCBs have excellent current limiting and selectivity characteristics. MCBs are available with C as well D tripping characteristics with current range of 0A - 5A and 0A - 00A respectively. Features at a glance Current limiting class MCBs Finger touch proof terminals (FTPT) Trip free mechanism Suitable for AC/DC circuits DIN rail and screw mounting possible Accessories like auxiliary contact, shunt trip, undervoltage release, fault signal contact Applications Mainly as an incomer MCB in residential, industrial and commercial applications C characteristics MCBs suitable for general line protection especially with higher starting current lamps, motors etc. D characteristics MCBs suitable for high inrush current applications line transformers generating significant pulses, solenoid valves etc. Technical data Standards IS/IEC 09 - : 00 Series 5SP Tripping characteristics C D Current range 0A, 00A and 5A 0A and 00A Rated voltage Operational voltage (max) Poles 0/5V AC and 0V DC/pole /0V AC and 0V DC/pole SP, DP, TP, FP Rated breaking capacity AC 0kA (as per IS / IEC 09) Depth Terminal tightening torque Conductor cross sections Solid and stranded Fine stranded with end sleeves Supply connection Ambient temperature Service life 70mm to.5nm 0.75 mm mm As required, top or bottom Polarity to be observed for DC applications -5 C to +5 C occasionally +55 C, max. 95% humidity, storage temp. -0 C to +75 C Average 0,000 operation at rated load Dimensions Betagard MCBs 5SP P P P P

17 and Isolators Type 5SP Type 5SP Selection and ordering data, LS5 5SP, 0kA MCBs with C/D characteristics IS/IEC 09 - Un: 0/5V, 0Hz can be used in systems upto 0Vdc,P and 0Vdc,P Standards: IS/IEC 09 - : 00 Breaking capacity: 0kA as per IS 09; With ISI marking: CM/L No. 555 C characteristic -pole Rated Current I n (A) MW # Reference No Std. Pkg. (Nos.).5 5SP07RC 5SP97RC 5SP97RC /0 /0 /0 -pole SP07RC 5SP97RC 5SP97RC /5 /5 /5 -pole SP07RC 5SP97RC 5SP97RC D characteristic -pole SP07RC 5SP97RC 5SP97RC -pole SP0RC 5SP9RC /0 /0 -pole SP0RC 5SP9RC /5 /5 -pole pole SP0RC 5SP9RC 5SP0RC 5SP9RC Also available wide range of Modular Devices for various applications * Insta Contactors Changeover switches Analog & Digital time switches Voltage Relays Digital Voltmeter & Ammeter Phase indicators Surge Protection Devices * For more details, kindly contact our sales office. 7

18 and Isolators Betagard Isolators Type 5TL all low res images Betagard Isolators Type 5TL Overview Isolators are used to switch lighting, motors and other electrical devices. They can be used as switch disconnectors according to IEC/EN Siemens 5TL Isolators can be retrofitted with auxiliary switches without tools in order to relay the switching state to a higher level. Features and Benefits Attractive design Easy-to-read, colored switch position indicator integrated in the handle Actuators in gray Ergonomically shaped handle and housing contours for user-friendly switching Streamlined introduction of terminals thanks to the rectangular terminal version for connecting busbars together with conductors from 0.75 to 5 mm² Effective reach-round touch protection Manual operation of the latching slide with locking option The ON/OFF switches are suitable for the easy and quick mounting of auxiliary switches Replacement of a device from a busbar assembly requires no tools

19 and Isolators Betagard Isolators Type 5TL Betagard Isolators Type 5TL Selection and ordering data Rated current I n (A) Reference No MW ( MW= mm) Std. Pkg. (Nos) Pole 5TL0 5TL00 5TL0 5TL00 5TL90 5TL90 / / / / / / Pole 5TL0 5TL00 5TL0 5TL00 5TL90 5TL90 / / / / / / Pole 5TL0 5TL00 5TL0 5TL00 5TL90 5TL90 / / / / / / Technical Specifications Betagard 5TL Standards IEC Mounting depth 70 mm Operating voltage / rated value 0 V AC Operating current / rated value A, 0A, A, 0A, 00A, 5A Number of poles Pole, Pole, Pole Short Circuit Withstand Capacity.5kA for.5 Seconds Utilization category AC A Rated Insulation Voltage 0 V Rated Impulse Withstand Voltage Kv Degree of Pollution Rated Duty Uninterrupted Duty Ambient Temperature -5 Celsius to +0ºCelsius Degree of protection IP 0 Terminals Size Solid and stranded Sq mm Finely stranded with end sleeve Sq mm Design of the switching function Switch Disconnector Dimensional drawings 5TL P P 5 P

20 and Isolators Accesories Overview The Siemens mounting concept supports the combination of all 5ST additional components with Siemens 5SY and 5SP miniature circuit breakers and with 5SU RCBOs. 5SL miniature circuit breakers are suitable for mounting auxiliary switches and fault signal contacts. Auxiliary switches can also be mounted on 5TL Isolators. Auxiliary switches (AS) The auxiliary switch (AS) always signals the contact position of the miniature circuit breaker, regardless of whether the miniature circuit breaker was tripped manually or as the result of a fault. An additional version is also available for the switching of small currents and voltages for the control of programmable control systems (PLCs) acc. to EN. The auxiliary switch with test button enables the testing of control circuits without the need to switch the miniature circuit breaker. Fault signal contacts (FC) The fault signal contact (FC) signals the automatic tripping of the miniature circuit breaker in the event of a fault, such as an overload or a short circuit. If the fault signal contact is activated, the contact position does not change if the miniature circuit breaker is tripped manually. Fault signal contacts with TEST and RESET buttons enable the testing of control circuits without the need to trip the miniature circuit breaker. The red RESET button integrated in the handle also indicates the automatic tripping of the MCB. The signal can be acknowledged manually using the RESET button. Shunt trips (units) Shunt trips are used for the remote tripping of miniature circuit breakers. Undervoltage releases (UR) Undervoltage releases are integrated (e.g. in EMERGENCY- OFF loops), thus ensuring that the MCB trips in the event of an emergency, which, in turn, ensures disconnection of the control circuit according to EN 00. In the event that the voltage is interrupted or too low, it also trips, i.e. prevents activation of the MCB. Remote controlled mechanisms (RC) Remote controlled mechanisms are used for the remote ON/OFF switching of miniature circuit breakers and the remote ON switching of RC units, as well as the local manual switching of these devices. A blocking function permits maintenance work. In the event that a miniature circuit breaker or RC unit is tripped, an acknowledgment must be carried out prior to switching back on. The remote controlled mechanism has an operating mode selector switch with the functions: Locked, Manual and Remote Switching. Position of selector switch: OFF: The remote controlled mechanism is switched off, blocked mechanically and can be sealed and/or locked. RC OFF: Only manual operation is possible. RC ON: Both manual and remote operation are possible. In the event that a device is tripped by a fault (RC units, miniature circuit breakers), the handle of the basic device and remote controlled mechanism switches to the OFF position. The operator must then acknowledge the tripping by resetting the remote controlled mechanism (OFF command) Benefits Accesories before it can be reactivated. This serves the safety of the installation or to protect personnel during maintenance work. In an RC unit/miniature circuit breaker combination, the RC unit is switched on asynchronously, i.e. prior to the miniature circuit breaker. The RC units for 5SY and 5SP can be switched ON via the MCB handle jumper using the supplied actuator attachment. There is no need to switch off the RC unit via the remote controlled mechanism as the MCB contacts ensure disconnection of the electrical circuit. The switching frequency is max. actuations per minute. If this actuation frequency is exceeded it may cause internal tripping of the remote controlled mechanism as a protection against possible overload. In this case, the remote controlled mechanism must be switched OFF at the function selector switch and not switched back on again for at least 5 minutes. More additional 5ST... components, such as AS, FC, units and UR, can be added to the right-hand side of the remote controlled mechanism in line with the Siemens mounting concept. Can be universally retrofitted with all additional components The 5SL, 5SY and 5SP miniature circuit breakers are ideal for the quick and easy mounting of auxiliary switches and fault signal contacts. Captive metal brackets on the additional components ensure the quick and easy mounting of devices on the miniature circuit breakers without the need for tools. low res image Fault signal contacts with TEST and RESET button enable the simple testing of auxiliary circuits and, in the event of a fault, acknowledgement of the fault over the RESET button, without the need to switch the miniature circuit breakers. low res image The auxiliary switches with TEST button enable the simple manual testing of control circuits during operation of the entire installation without the need to switch the miniature circuit breakers. 0

21 and Isolators Accesories Accesories Technical Specifications Auxiliary switches (AS) Fault signal contacts (FC) 5ST 00, 5ST 00-5ST 0, 5ST 0-5ST 0, 5ST 0-5ST 0, 5ST 0-5ST 0, 5ST 0-5ST 05, 5ST 05-5ST 00, 5ST 00-5ST 0, 5ST 0-5ST 0, 5ST 0- Standards EN 09; IEC/EN ; UL 077; CSA C. No. 5 Short-circuit protection Miniature circuit breaker or gg A fuse Contact load Min. Max. 00 V AC, AC-, NO 0 V AC, AC-, NO 00 V AC, AC-, NC 0 V AC, AC-, NC 0 V DC, DC-, NO+NC 0 V DC, DC-, NO+NC 0 V DC, DC-, NO+NC V DC, DC-, NO+NC A A A A A A A A ma, V ma/5 V DC ma/0 V DC ma, V Service life, on average, with rated load 0000 actuations 0000 actuations 0000 actuations Conductor cross-sections mm Terminals Terminal tightening torque Nm Mounting position Any Any Any Ambient temperature Storage temperature Undervoltage releases (UR) Shunt trips (units) Remote controlled mechanisms (RC) 5ST 0. 5ST 00 5ST 0 5ST 0 Standards EN 097- Rated voltages U n V AC V DC 0, Operating range U n Rated frequency f n Response limits Hz x U n x U n x U n... 0 Tripping < Un Short-circuit protection Miniature circuit breakers B/C A or fuse gg A Minimum contact load ma, V ma, V Tripping operations max. 000 max. 000 Service life, on average, with rated load 0000 actuations 0000 actuations 0000 actuations 00 at RC unit Conductor cross-sections mm Terminals Terminal tightening torque Nm Mounting position Any Any Any Ambient temperature C Storage temperature C Switching frequency actuations per minute Switching duration s < Minimum command duration s 0. continuous command possible Rated power dissipation VA No power consumption, in switching operation Behavior in the event of control voltage failure No change

22 and Isolators Accesories Accesories Selection and ordering data Rated current U n V MW ( MW= mm) Reference No Std. Pkg. (Nos) Auxiliary switches (AS) For 5SL, 5SY, 5SP miniature circuit breakers, 5SU RCBOs and 5TL Isolators NO + NC For low power 0.5 5ST 00 5ST 0 NO For low power 5ST 0 5ST 0 NC For low power 5ST 0 5ST 05 Auxiliary switches (AS) with TEST button For 5SL, 5SY, 5SP miniature circuit breakers, 5SU RCBOs and 5TL Isolators NO + NC For low power 0.5 5ST 00-5ST 0- NO For low power 5ST 0-5ST 0- NC For low power 5ST 0-5ST 05- Fault signal contacts (FC) For 5SL, 5SY, 5SP miniature circuit breakers and 5SU RCBOs NO + NC NO NC 0.5 5ST 00 5ST 0 5ST 0 Fault signal contacts (FC) with TEST and ACKNOWLEDGE button For 5SY, 5SP miniature circuit breakers and 5SU RCBOs NO + NC NO NC 0.5 5ST 00-5ST 0-5ST 0- Undervoltage releases (UR) For 5SY, 5SP MCBs and 5SU RCBOs With integrated auxiliary switch low res images Without integrated auxiliary switch 0 AC 0 DC DC 0 AC 0 DC DC Shunt trips (units) For 5SY, 5SP MCBs and 5SU RCBOs V AC... 0 V AC/DC 5ST 00 5ST 0 5ST 0 5ST 0 5ST 0 5ST 05 5ST 00 5ST 0 Remote controlled mechanisms (RC) For 5SY and 5SP MCBs and 5SU RCBOs 0 AC.5 5ST 0

23 and Isolators Accesories Accesories Selection and ordering data Version Handle locking devices Sealable to prevent undesired mechanical ON/OFF switching For 5SP and 5SY miniature circuit breakers For padlock with max. mm shackle MW ( MW= mm) Reference No 5ST 0 Std. Pkg. (Nos) For 5SL miniature circuit breakers For padlock with... mm shackle 5ST 0 5 Padlocks For 5ST 0 and 5ST 0 handle locking devices 5ST 0 Rotary Handle Assembly Benefits 5SJ, 5SL, 5SP, 5SY and 5TL series of MCBs/ Isolators can be fitted with Betagard Rotary Handle Assembly (ROH) for installation in Switchgear Cubicles and Distribution Panels The ROH can be padlocked in OFF position with the help of suitable padlocks thereby ensuring complete safety to operating personal during maintenance. Door interlock and defeat facility is available as a standard feature. The ROH gives operating uniformity and improves the aesthetics of the panel. Technical Details: Product Order No Weight item Kg Rotary Handle Assembly 5ST0RC 0.5 Std. Pkg. (Nos) Accessory mounting guide Rotary handle ST 5TL AS AS OV 5SY/5SP/5SU RC ST/UR/OV/OU 5SL AS / FC C FC / AS Lock device Remote control(rc) AS / FC FC Busbar FC / AS UR

24 Your partners Sales offices: Ahmedabad rd Floor, Prerna Arbour Girish Coldrinks Cross Roads Navrangpura Ahmedabad ( : Fax: Baroda Ground Floor, Urja Bhavan Opp.Makarpura Railway Station Maneja Vadodara ( : Fax: Bengaluru st Floor, Jyoti Mahal No. 9, St. Marks Road Bengaluru - 00 ( : Fax: +9 0 Chandigarh SCO /9, rd Floor, Sector-7 C Chandigarh ( : Fax: Chennai th Floor, ETA Mount Central Seethakathi Business Centre, Mount Road Chennai ( : Fax: Coimbatore st Floor, Senthil Towers 07, Avinashi Road Coimbatore - 0 ( : Fax: Gurgaon Plot No -7, Tower B Jagatjit Industries Building (JIL) Opposite SBI Academy, Sector- Gurgaon - 05 ( : , 000 Hyderabad 5-9-9, th & 5th Floor Laxmi Narasinh Estate Opp. Secretariat Road Saifabad Hyderabad ( : Fax: Jaipur, Park Street Opp. Pink City Petrol Pump M.I.Road Jaipur , Rajasthan ( : +9 5 Fax: Jamshedpur Roshan Tower Main Road, Bistupur (nd Floor) Jamshedpur - 00 ( : Kolkata 5th Floor, Infinium Digispace CP - 5, Sector V, Salt Lake Kolkata ( : Fax: Lucknow /5, Ashok Marg Opp. Indira Bhawan Lucknow - 00 ( : , 0000 Fax: Mumbai Business Centre- Thane Belapur Road Thane ( : Fax: Nagpur 5th Floor, Land Mark Building Wardha Road, Ramdas Peth Nagpur ( : Fax: Pune Tower B/70-705, ICC Trade Tower 0A, Senapati Bapat Road Pune - 0 ( : Fax: Vishakhapatnam nd Floor, 0--7 Lakshmi Narasimha Towers Banu Street, Daba Gardens Visakhapatnam - 00 Andhra Pradesh ( : Fax: Territory managers: Agra, Maitri Bagh, Dayal Bagh Agra-005, UP Mobile: achint.mathur@siemens.com Angul Plot No. 097, st Floor At-Bhandubar (Near RMC Gate) Via - Hakimpada. P.O.- Kumanda Dist. - Angul, Odhisa Mobile: sudipta.garnayak@siemens.com Aurangabad Flat No. 0, Building A Disha Sanskruti Silkcity, Paithan Road Aurangabad - 00 (MH) Mobile: Prashant.Joshi@siemens.com Belgaum H.No. 7, Narvekar Lane, Shahpur Belgaum , Karnataka Tel.: Mobile: anand.gawade@siemens.com Belgaum Flat No. 7, nd Floor, Jyotirling Plaza Congress Road, Thilakwadi Belgaum , Karnataka Mobile: prathish.t_m@siemens.com Bharuch Gold B, 0, Samruddhi Residency Opp. Zadeshwar Bus Stop, Zadeshwar Road Bharuch - 90 Mobile: kalpeshkumar.darji@siemens.com Bhilai Flat No. M-0, Rishabh City Prime Potia kala, Durg (CG) Mobile: pravin.deshbhratar@siemens.com Bhopal Flat No. 0, Sagar Home Phase- Sarvadharma Society, Sector A Nayapura Road, Bhopal - 0 Madhya Pradesh Mobile: prajwal.khapekar@siemens.com Bhubaneswar Plot No. 597, Infront of Fishery Lane Chintamaniswar, Bhubaneswar - 70 Odisha Mobile: sumit.sengupta@siemens.com Bhubaneswar Archid Royal Apartment, Flat No. 0 Nageswar Tangi, Bhubaneswar - 70 Odisha Mobile: pm.barik@siemens.com Boisar Flat No. 0, A Wing Mahavir Shrishti Apartments Near Madhur Hotel, Navapur Road Boisar, Thane (W) - 0 Mobile: deashis.biswas@siemens.com Cochin K.G.Oxford Business Centre A, Shreekandath Rd, Ravipuram Cochin - 0 Tel.: +9 0/ Mobile: girish.v_nair@siemens.com Cochin K.G.Oxford Business Centre A, Shreekandath Rd, Ravipuram Cochin - 0 Mobile: abhishek.tyagi@siemens.com Cochin K.G.Oxford Business Centre A, Shreekandath Rd, Ravipuram Cochin - 0 Mobile: vinu.pillai@siemens.com Dehradun, Dhronpuri, Main Lane G.M.S.Road, Deharadun - 00 Uttarakhand Mobile: shashibhushan.prasad@siemens.com Durg Anandvihar Phase-, Plot No. Borsi South, Durg - 900, (CG) Mobile: jitendra.potdar@siemens.com Durgapur C/o Anjan Sadhu /, A.K. Bithi City Center, P.O. Durgapur - 7 Nearest Landmark - Bidisha Residential Complex Mobile: saurav.bhowmik@siemens.com Goa House No S-, Classque Appartment Porvorim, Goa - 0 Mobile: jithin.jacob@siemens.com Gulbarga Flat No., rd Floor, Shubha Residence Deshmukh Layout, Drajmapur, Kalaburagi Gulbarga District - 5 Karnataka Mobile: anirudh.ganta@siemens.com Guwahati House No. 0, Ushanagar Dispur Supermarket, Guwahati Assam Mobile: biplab.datta@siemens.com Hospet Ramanand Residency, Flat No. 0 st Main, Nehru Co-op Colony Hospet -, Karnataka Mobile: roy.sanjib@siemens.com Hospet # 77, Lakshmi Narasimha Nilaya Near Surbhi Kalyana Mantapa, Amaravathi Hospet - Mobile: naveen.sn@siemens.com Hosur # B, Sunshine st Floor Sipcot Housing Colony, Dharga Hosur - 5, Tamilnadu Mobile: kamalanaban.tv@siemens.com Hubli #, Sri Mallikarjuna Nilaya, st Floor Somanagowdara Layout, Bengeri Extension Hubli - 0, Karnataka Mobile: kr.purushottam@siemens.com Indore Govind Dham, Ahilyapuri Near Residency Club Indore - 0 (MP) Mobile: raghvendra.bhadouria@siemens.com Indore C/o Dr. Mahesh Malviya, House No. Scheme No., Part Indore - 0, M.P. Mobile: rohit.seth@siemens.com Jajpur Kirtan Enclave, Flat No., C Block Chhordha Chaak, Jajpur Keonjhar Road Jajpur (Nearest Land Mark - SBI ATM counter) Mobile: probir.mukherjee@siemens.com Jalandhar H.No. 0, Second Floor, Defence Colony Jalandhar, Punjab - 00 Mobile: himanshu.kaushik@siemens.com Jammu H.No. # A, Sector # Extension Friends Colony, Near Marble Market Trikuta Nagar Extension, Jammu Mobile: chander.parkash@siemens.com Jodhpur D-, Near Sai Baba Mandir, Shankar Nagar Pal Road, Jodhpur Mobile: jain.nitin@siemens.com Kanpur Flat No. 07, Gulmohar Garden Phase I Shastri Nagar, Kanpur , UP Mobile: shagun.gupta@siemens.com Khopoli Flat A, Dutta Krupa Housing Society Upper Khopoli, Near Datta Mandir Khopoli - 00 Mobile: vilas.bhosale@siemens.com Kolhapur RS No. -, Pinac Prasad, Flat No. A-5 New Palace Road, Kolhapur - 00 Mobile: vinay.todkar@siemens.com Kota 0, Manglayatan Appartments Near Jain Mandir, Bhimganj Mandi Kota - 00 Mobile: avinash.mathur@siemens.com Ludhiana H.No. 90, Street No., Jaswant Nagar Near Samrala Chowk, Ludhiana - 00 Mobile: sunil.singla@siemens.com Ludhiana 9/, J Block B.R.S.Nagar, Ludhiana (PB) Mobile: bhatia.sandeep@siemens.com Ludhiana R-5 Near DAV School Sarabha Nagar Extension Phase - Pakhowal Road Ludhiana, Punjab Mobile: padam.sharma@siemens.com Madurai Anirudh Block F-Top, Vasudhara Apt., TPK Main Road, Andalpuram Madurai - 0, Tamil Nadu Mobile: sivaprakasam.r@siemens.com Meerut E-05, Ansal Courtyard, Roorkee Bypass Modipuram, Meerut - 0, UP Mobile: singh.vineet@siemens.com Meerut C-90, Ansal Courtyard, Roorkee Bypass Modipuram, Meerut - 0, U P Mobile: shailendra.kumar@siemens.com Mysore #, Ground Floor, th Cross rd Main, st Stage, C Block, J.P. Nagar Mysore Mobile: niranjan.kv@siemens.com Nashik, Nirman Classic Appartment Thatthe Nagar, Behind HDFC Bank Nashik Mobile: shailesh.bakshi@siemens.com Nashik Flat No. A-0, Brindavan Gardens Kedar Nagar, Shramik Nagar Near Satpur MIDC, Nashik 0 Mobile: jugal.shah@siemens.com Neemrana Flat No. F, Anantraj Apartments Neemrana Distt. Alwar Mobile: deepak.beniwal@siemens.com Panipat H.No. 5, First Floor Near Police Chownki, HUDA Housing Board Sector, Panipat Mobile: Patna Anubhuti Apartment, Flat No. 0 North Anandpuri, West Boring Canal Road Patna Mobile: vikash.prasad@siemens.com Pondicherry No., th Cross Street, Anna Nagar Pondicherry Mobile: lakshmanan.s@siemens.com Raipur 0 Risabh Regency Near Shri Medishine Hospital New Rajendra Nagar Raipur (C G) Mobile: raghuraj.bisen@siemens.com Rajahmundry Plot No. 0, SVR Residency Door No. 779/, Gandhipuram - Rajahmundry Dist. East Godavari - Andhra Pradesh Mobile: naga.ganesna@siemens.com Rajkot Vrujraj, Chandanpark Society Opp. Gyanganga Vidhyapith, Nr.Raiya Circle Rajkot , Gujarat Mobile: hiren.raithatha@siemens.com Ranchi Flat No. A-0, st Floor Sundaram Apartment, Kilburn Colony Hinoo, Ranchi, Jharkhand - 00 Mobile: shyamal.bhattacharyya@siemens.com Renukoot Raj Bhawan (Near Khatu Shyam Mandir) Awadh Colony, Murdhwa, Renukoot Sonebhadra - 7 Mobile: umesh.pandey@siemens.com Rourkela D/, Gafoor Colony, nd Floor Near LIC Office, Udit Nagar Rourkela - 790, Odisha Mobile: prakhar.chaturvedi@siemens.com Rourkela N/, Flat No. A, Civil Township Opposite Hi-tech Medical College & Hospital Rourkela, Odisha Mobile: shouvik.mitra@siemens.com Rudrapur Flat No. 0, Tower Ganges C Omaxe Reviera Rudrapur - 5, Uttarakhand Mobile: ashish.bhatt@siemens.com Rudrapur Flat No. 0, Tower Rhone C Omaxe Reviera Ltd. Rudrapur - 5, Uttarakhand Mobile: abhinav.rastogi@siemens.com Salem Rajagiragham, Lumbini Illam No. 0, Palaniappa Nagar Hasthampatti Salem Mobile: g.suresh@siemens.com Sonepat H.No. 0, st Floor, Sector- Sonepat - 00, Haryana, India Mobile: kumar.manish@siemens.com Sriperumbudur /, Sathyanarayanapuram, Moulivakkam Porur, Chennai - 00 Mobile: venkatesh.janakiraman@siemens.com Surat /A, Navrachana Society, Opp. D.K.Park Bhatar Road, Surat - 90 Mobile: mitul.kapadia@siemens.com Surat A 0, Stuti Universal, Green City Road Pal-Adajan, Surat - 909, Gujarat Mobile: harshwardhan.mishra@siemens.com Trichy /09-B, th Cross Street, West Extension Vasan Nagar, Rettai Vaikkal, Vayalur Road Tirchy - 00 Mobile: Muthu.kumar@siemens.com Trivandrum No.7-A, Vishnu Bhawan, Swathy Nagar (SNRA-), Kazhakuttom, Trivandrum Mobile: nobin.babu@siemens.com Udaipur A-9, New Ahinsapuri, Fatehpura Udaipur (Rajasthan) - 00, India Mobile: anurag.shah@siemens.com Ujjain Amit Singh Bhadauria, Tirupati Hights B-block, Flat No. 0, Nana Kheda Dipti Parisar, Ujjain-Indore Road Ujjain - 0 (MP) Mobile: Bhadauria.amit@siemens.com Vapi Flat No. 0, A Wing, Madhav Gems Nutannagar, Valsad Road, Vapi (East) Valsad Dist, Vapi - 99 Mobile: pandey.abhishek@siemens.com Vapi Shubham Tower No., C Wing Flat No.00, Chala, Vapi Daman Road, Vapi Mobile: s.anand@siemens.com Vijayawada Laxmi Nivas, st Floor, Flat No. FF / & /, Plot No. 0 Sundarayya Nagar, Payakapuram Vijayawada - 05, Andhra Pradesh Mobile: venkateswar.d@siemens.com Siemens Ltd. Digital Factory Control Products R&D Technology Centre Kalwa Works, Thane Belapur Road Thane Fax: lvsgr-mktg.india@siemens.com Order No. 07 DF-CP-LPCC0705 (This replaces GP ) Customer Care Toll free no ics.india@siemens.com Product upgradation is a continuous process. Hence, data in this catalog is subject to change without prior notice. For the latest information, please get in touch with our Sales Offices.

Smart. Easy. Reliable.

Smart. Easy. Reliable. s Smart. Easy. Reliable. Monitoring Relay 7UG0 and Timers 7PV0 Smart. Easy. Reliable. The continuity of electrical power supply is very important especially for the industrial sector where a stoppage of

More information

Smart. Easy. Reliable.

Smart. Easy. Reliable. 3TS Converter duty contactor Smart. Easy. Reliable. www.siemens.co.in Overview: For more than 125 years, Siemens has been developing and manufacturing industrial control products. We offer a wide product

More information

Smart. Easy. Reliable. 7RQ Plug-in Relays.

Smart. Easy. Reliable. 7RQ Plug-in Relays. s Smart. Easy. Reliable. 7RQ Plug-in Relays www.siemens.co.in Smart. Easy. Reliable. Siemens offers a wide range of Plug-in relays to meet your industrial needs. The entire Plug-in Relays range is manufactured

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

Modular design for all applications

Modular design for all applications SIRIUS 3SE5 Position Switches Modular design for all applications www.siemens.co.in Introduction: Accurate and dependable: SIRIUS detecting devices stand guard There is a lot of information in the field.

More information

Miniature Circuit Breakers for Railway Applications

Miniature Circuit Breakers for Railway Applications Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent

More information

Smart. Easy. Reliable. Automatic Power Factor Controller Relay 7UG05 for optimized power need.

Smart. Easy. Reliable. Automatic Power Factor Controller Relay 7UG05 for optimized power need. Smart. Easy. Reliable. Automatic Power Factor Controller Relay 7UG05 for optimized power need. www.siemens.co.in 7UG05 Automatic power factor correction relay Controls the required Power factor Manage

More information

5SL Miniature Circuit Breakers

5SL Miniature Circuit Breakers 5SL Miniature Circuit Breakers BETA Low-Voltage Circuit Protection The new 5SL miniature circuit breaker is intended for use up to ka. The devices have the system features characteristic of all Siemens

More information

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical

More information

Appendix 08: Details of Location under Each Category

Appendix 08: Details of Location under Each Category Appendix 08: Details of Location under Each Category Dated: Sr. No. A Bank Location CATEGORY - A Type of 1 Hyderabad - DR DR Site Telangana 2 Mumbai - DC DC Site 3 Mumbai- DC 4 Bangalore-

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................

More information

3SB5 Datasheet 3SB5. Indicating lamps and push buttons.

3SB5 Datasheet 3SB5. Indicating lamps and push buttons. 3SB5 Datasheet 3SB5 Indicating lamps and push buttons www.siemens.co.in Control at your finger tips Index Device Types Pg 03 Benefits Pg 04 Overview Pg 05 Selection and ordering data Pg 06 Technical Data

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................

More information

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Soft starter- ASAB 1

Soft starter- ASAB 1 Soft starter- ASAB 1 ASAB-Series Soft starter Soft start/stop static starters for three-phase asynchronous motors. The ASAB is an advanced digital soft start solution for motors from 7 kw to 800 kw. ASAB

More information

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...

More information

Product Guide. UL 1077 DIN Rail Supplementary Protectors

Product Guide. UL 1077 DIN Rail Supplementary Protectors Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

Miniature circuit breakers for all applications

Miniature circuit breakers for all applications Miniature circuit breakers for all applications BETA Low-Voltage Circuit Protection Answers for infrastructure. BETA Low-Voltage Circuit Protection: Circuits under Control, Wherever, Whenever. Whether

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide

More information

Residual Current Protective Devices / Arc Fault Detection Devices

Residual Current Protective Devices / Arc Fault Detection Devices Residual Current Protective Devices / Arc Fault Detection Devices SENTRON Configuration Manual Edition 10/015 siemens.com/lowvoltage Introduction 5SV / 5SM3 RCCBs 13 SIQUENCE 5SM3/5SU1 universal current

More information

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

UL 489 Cable-In / Cable-Out Branch Circuit Breaker Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

TeSys contactors From 115 to 2750 A

TeSys contactors From 115 to 2750 A Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,

More information

CALL LOGGING PROCESS

CALL LOGGING PROCESS CALL LOGGING PROCESS 1. TO REGISTER A COMPLAINT, FIRST YOU NEED TO REGISTER YOUR PRODUCT ON VIVITEK WEB SITE. BELOW ARE THE STEPS TO REGISTER YOUR PRODUCT ON VIVTEK WEB SITE. 2. LOG ON TO WWW.VIVITEK.IN

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

Video Door Phone Collection 2017

Video Door Phone Collection 2017 Door Phone Collection 2017 Safe Home with Crabtree Door Phone Add Security to your lifestyle Crabtree VDP products are designed and developed to the highest quality standards for individual residential

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

Energy Saving HRC Fuse-Links

Energy Saving HRC Fuse-Links Energy Saving HRC Fuse-Links Blade Type HN 3 A - 800 A Cylindrical Type HF A - 3 A L&T, India's largest manufacturer of low tension switchgear, offers the new generation of low watt loss HRC fuse-links

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers .2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................

More information

RTU500 series Data Sheet Power Supply CP-E 24/2.5

RTU500 series Data Sheet Power Supply CP-E 24/2.5 Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped

More information

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths DATASHEET - ESR5-NO-41-24VAC-DC Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths Part no. ESR5-NO-41-24VAC-DC Catalog No. 118701 EL-Nummer (Norway) 0004133317 Delivery program Product

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

CANARA BANK NRI CELL, CIRCLE OFFICE 1ST FLOOR, RED CROSS BHAVAN SACHIVALAYA MARG BHUBANESWAR : ODISHA, INDIA E MAIL ID:

CANARA BANK NRI CELL, CIRCLE OFFICE 1ST FLOOR, RED CROSS BHAVAN SACHIVALAYA MARG BHUBANESWAR : ODISHA, INDIA E MAIL ID: CONTACT DETAILS For any information/clarification/grievance on matters connected with NRIs, please contact our BRANCHES spread across the country: NRIs may also contact the following NRI Cells/Offices.

More information

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities. KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA

More information

CS8 Industrial Control Relays

CS8 Industrial Control Relays CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum

More information

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC Characteristics adjustable off-delay timing relay - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay

More information

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB Motors Automation Energy Transmission & Distribution Coatings DWB Molded Case Circuit Breakers DWB Molded Case Circuit Breakers Molded Case Circuit Breakers DWB Summary Presentation 0 General Characteristics

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60 DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

Thermal-Magnetic Circuit Breaker 4220-T...

Thermal-Magnetic Circuit Breaker 4220-T... Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With

More information

SENTRON SIVACON ALPHA

SENTRON SIVACON ALPHA SENTRON SIVACON ALPHA Low-Voltage Power Distribution and Electrical Installation Technology Catalog Extract LV 10 Edition 10/2018 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

RB60 RANGE. Miniature circuit breakers

RB60 RANGE. Miniature circuit breakers RB60 RANGE Miniature circuit breakers POWER 2015 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor

More information

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0

More information

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation ARC FAULT DETECTION DEVICE (AFDD) The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation The S-ARC1 is the new Arc Fault Detection Device (AFDD) with an integrated Miniature Circuit

More information

Product Guide. UL 489 DIN rail miniature circuit breakers

Product Guide. UL 489 DIN rail miniature circuit breakers Product Guide UL 489 DIN rail miniature circuit breakers UL 489 DIN rail miniature circuit breakers Product Overview................................................ 2 Product Selection WMZT 10 kaic at

More information

DESIGN YOUR WORLD WITH YOUNG ENERGY

DESIGN YOUR WORLD WITH YOUNG ENERGY DESIGN YOUR WORLD WITH YOUNG ENERGY S w i tc h es & Plat e s List Price w.e.f. 23rd Oct. 2017 STANDARD SWITCHES 2 STANDARD SWITCHES 3 Switches & Plates SWITCH MODULE 10AX One way switch ASZSXXW101 8536

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

Disconnect Switches. Safe Switching and Disconnecting

Disconnect Switches. Safe Switching and Disconnecting IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as

More information

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

Solid State Remote Power Controller E /627

Solid State Remote Power Controller E /627 Solid State Remote Power Controller E--623/62 Description The E-T-A Solid State Remote Power Controllers E--623/62 are electronic control modules suitable for inductive loads such as electromagnetic valves

More information

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit

More information

Electronic timer CT-ERS.21

Electronic timer CT-ERS.21 2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width

More information

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka) MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and

More information

Electronic timer CT-ARS.11

Electronic timer CT-ARS.11 2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact

More information

Ahmedabad Amritsar Bangalore Bathinda

Ahmedabad Amritsar Bangalore Bathinda Ahmedabad 3rd Floor, Navneet Plaza, Near Municipal Market, CG RoadAhmedabad 380001 Guj arat Tel: +91 079 400 491 00-104 Email:ahmedabad@canamgroup.com Amritsar SCO-37, 3rd Floor, District Shopping Complex,

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field

More information

Voltage Dip-Proofing Inverter

Voltage Dip-Proofing Inverter Voltage Dip-Proofing Inverter DPI54S / 54L Series Models 120V & 208/230 50/60Hz Contents: Introduction...3 Theory of operation...3 Specifications...5 Up-time considerations...6 Installation Guide...7 Test

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

SMART WIREFREE. Home Automation Solutions

SMART WIREFREE. Home Automation Solutions Home Automation Solutions Collection 2017 What is Home Automation? Home automation systems are designed to make a home owners life more comfortable, convenient and secure. With a range of solutions available

More information

Betagard Inspiring Safety. Answers for infrastructure.

Betagard Inspiring Safety. Answers for infrastructure. s etagard Inspiring Safety Answers for infrastructure. www.siemens.co.in Low-Voltage Electrical Installation Technology etagard iniature ircuit reakers & etagard D ircuit reakers etagard Residual urrent

More information

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards) ////// SUBSTATIONS DC Switchgear Range Type MBS (IEEE/ANSI standards) GENERAL INFORMATION With a complete range of equipment and a leading expertise in DC traction power substations, Sécheron SA is a world

More information

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range) Data sheet Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range) The CP-B 24/20.0 serves to ensure a shortterm uninterrupted power supply

More information

SIRCO Load break switches for power distribution from 125 to 5000 A

SIRCO Load break switches for power distribution from 125 to 5000 A The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct

More information

DSE201, DSE201 M Compact design with enhanced protection

DSE201, DSE201 M Compact design with enhanced protection DSE20, DSE20 M Compact design with enhanced protection Ultimate safety DSE20 and DSE20 M: the highest level of reliability The P+N electronic residual current circuit-breakers with overcurrent protection

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton K-Line Ordering Informaiton K-Line Ordering Information Control Relays - Mounting on 35 mm DIN3 track or 4 screw direct mounting. - Screws in open ready-to-tighten position. Control Circuit Contact Configuration

More information

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts Data sheet Electronic timer CT-SDS. Star-delta change-over with n/o contacts The CT-SDS. is an electronic timer from the CT-S range with Star-delta change-over and 7 time ranges. All electronic timers

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information