Excel 10 Q7750A ZONE MANAGER BEFORE INSTALLATION. Parts Checklist INSTALLATION INSTRUCTIONS

Size: px
Start display at page:

Download "Excel 10 Q7750A ZONE MANAGER BEFORE INSTALLATION. Parts Checklist INSTALLATION INSTRUCTIONS"

Transcription

1 Excel 10 Q7750A ZONE MANAGER BEFORE INSTALLATION These Installation Instructions are applicable for the Q7750A Excel 10 Zone Manager. There are two versions of the Q7750A: series Twisted Pair Topology E-Bus transceiver series Free Topology E-Bus transceiver, including revision 2 software. Only trained technicians are allowed to work on the installation of the Q7750A hardware and to change the EPROMs or the Submodule within the hardware. The Q7750A Excel 10 Zone Manager is fully assembled and tested at the Honeywell Factory and is shipped with the appropriate literature. Parts Checklist Q7750A Excel 10 Zone Manager with mounting base. Installed internally are the operating system EPROMs. Ferrite ring (supplied with 2000-series devices). Excel 10 Q7750A Installation Instructions, form number Excel 10 Q7750A Checkout and Test, form number (1000-series devices only). E-Vision User Guide, form number (2000-series devices only). Options: XD505A (standard) or XD508 (1 megabit/s baud rate) C-Bus communications submodule or XDM506 modem submodule. Not included with the Excel 10 Q7750A order, but needed for every Excel 10 Q7750A application are: INSTALLATION INSTRUCTIONS 24 Vac power source for the Q7750A Excel 10 Zone Manager. PC with Microsoft Windows, CARE software and/or E-Vision software and Protection Block. Communications cable for the PC to Q7750A Excel 10 Zone Manager; the XW ft 6 in. (5m); the XW ft 6 in. (15m); or the XW567 8 ft 3 in. (2.5m). NOTES: Each Q7750A Excel 10 Zone Manager requires 24 Vac power. The following information is given for US applications: For a standalone interface device, use the 24 Vac power from a 115/24 Vac (230/24 Vac) 2A, 50 VA, UL listed, Class II Transformer ( ). When conditioned power is required, use a 24 Vac or -004 Power Module (115 Vac, and 230 Vac, respectively). For multiple interface devices, use the 24 Vac power from a 115/24 Vac (230/24 Vac) 6A, 150 VA, UL listed, Transformer (see NOTES in Wiring Section when using a transformer greater than 100VA). When conditioned power is required, use a 24 Vac , or -005, -006 Power Module (115 Vac and 230 Vac, respectively). (When using any of the Power Modules, use Cable Assembly to connect the 24 Vac power to the mounting base of the interface device.) Power can be provided optionally by installing a fuse and an On/Off switch on the primary side of the 24 Vac transformer. Fig. 1. Excel 10 Zone Manager dimensions. U.S. Registered Trademark Copyright 2000 Honeywell Inc All Rights Reserved

2 INSTALLATION 1. Unpack the Q7750A Excel 10 Zone Manager. Report any damage to a Honeywell Representative. Installing the Mounting Base To install the mounting base, remove it from the Q7750A Excel 10 Zone Manager housing. 1. Remove the front cover of the Q7750A Excel 10 Zone Manager by pressing in and down on the plastic ridges located on the front and center of the device. See Fig Separate the housing from the mounting base. See Fig. 4. NOTES: Be aware of the rubber grommet under the device housing that holds the brass screw in place. Where Electro-Magnetic Interference (noise) emissions must be considered, install the Q7750A Excel 10 Zone Manager in a ring cabinet that is earth grounded. There are two ways to install the mounting base: 1. On standard EN DIN rail, 1-3/8 by 9/32 in. (35 by 7.5 mm), which is fastened with screws to a vertical surface. (Type of screws used such as sheet metal, selftapping or thread forming and the screw lengths are determined by the type of mounting material at the job site.) 2. By fastening the mounting base, with screws, directly to a vertical surface. Fig. 2. Open cover. 2. Remove the special metal tool located near the bottom of the housing. See Fig. 3. Fig. 3. Take out tool. Fig. 4. Remove brass screw, and loosen and remove Q7750A Excel 10 Zone Manager housing from mounting base

3 To mount the base to standard DIN Rail: 1. Attach two DIN rails, which are a minimum of 6 in. (155 mm) in length, with appropriate screws for the mounting surface. Space the two DIN rails 4-7/8 in. (124 mm) apart, measured from the top of each DIN Rail, while keeping them both horizontal and parallel. See Fig. 5. Fig. 7. Position and secure mounting base. Fig. 5. Attach DIN rails. 2. Loosen the metal screw on the bottom of the mounting base and hang the mounting base on the DIN rails using the plastic flanges located on the back of the mounting base. See Fig. 6. To mount the base using screws: 1. Orient the mounting base vertically on the mounting surface. Using the three screw holes (two located at the bottom corners of the base and one at the top center), mark the positions for the three no. 8 (4.0 mm) mounting screws. After the positions are marked, attach the base to the surface with the appropriate mounting screws. See Fig. 8. Fig. 6. Hang mounting base into place. 3. Slide the metal screw up against the lower flange of the bottom DIN rail and tighten the screw. See Fig. 7. Fig. 8. Attach mounting base with screws. NOTE: Wiring must enter the mounting base from the bottom; to prepare wire access holes:

4 1. Break off one or two of the plastic tabs just left of the metal screw on the mounting base for wiring access and routing to the lower left terminal block. See Fig. 9. Power Wiring Input Power: 24 Vac, 50/60 Hz. Wire 24 Vac power using the heaviest gauge UL level IV or plenum rated UL level IV wire available, up to 14 AWG (2.0 mm 2 ) with a minimum of 18 AWG (1.0 mm 2 ) wire. For nonplenum, open areas, run cables exposed (or in conduit if required; see the following NOTES). NOTES: The Q7750A Excel 10 Zone Manager must have a dedicated transformer/power source. Do not power any accessories with the Q7750A Excel 10 Zone Manager transformer/power source. Keep the transformer/power source as close as possible to the Q7750A Excel 10 Zone Manager so the power wiring will be as short as possible; the maximum length is 6 ft. 6 in. (2m). (US only) When using a 24 Vac transformer larger than 100 VA, Class II power requirements will be exceeded and the power wiring must be enclosed in conduit. Fig. 9. Break off plastic tabs for wiring access to lower left terminal block. Wiring NOTES: All wiring must comply with applicable electrical codes and ordinances. Refer to job drawings or manufacturer s drawings for details. All wiring terminals are located on the inside of the front cover. Pass all wires through the appropriate holes from the broken plastic tabs (see Fig. 9). Route wires and tie-wrap according to Fig. 12. CAUTION Make certain no line power is applied to the transformer/power source to prevent device from being attached with power on. Mounting base power must remain off until installation and wiring is checked by a control system representative. 1. Connect 24 Vac secondary side of the transformer/power source to terminals 1 and 2 on the mounting base according to job drawings. See Fig. 10. C-Bus Wiring Wire the C-Bus using cable according to Table Connect the C-Bus cable by attaching the shield to terminal 18, the positive lead to terminal 16 and the negative lead to terminal 17 according to job drawings. See Fig. 10. E-Bus Wiring Wire the E-Bus using Level IV 22 AWG (Belden part number 9D220150) or plenum-rated level IV 22 AWG (Belden part number 9H ) nonshielded, twisted pair, solid conductor wire, as the recommended wire. When possible, use Honeywell AK3781, AK3782, AK3791, or AK3792 cable (US part numbers). For additional information regarding E-Bus wiring see E-Bus Wiring Guidelines, form number Table 1. C-Bus cable types. Maximum baud rate Cable type Description Remarks 76.8K JY (St) Y 2x2x0.8 shielded, twisted pair AK3702 unshielded, twisted pair US only AK3740a shielded US only 921.6K Belden 9842 twisted pair Belden 9841 shielded US only AK3702 unshielded, twisted pair US only AK3740A shielded US only

5 1. Connect the E-Bus wire by attaching one lead to terminal 5 and the other lead to terminal 6 according to job drawings. See Fig. 9. IMPORTANT For 2000-series devices the E-Bus must be wound one turn through a ferrite cylinder (supplied with the device) a maximum of 7/8 in. (20 mm) from the housing. See Fig. 10. NOTES: The E-Bus is insensitive to polarity, eliminating installation errors due to miswiring. To minimize EMI noise, do not run Triac output wires in the same conduit as the input wires or the E-Bus communications loop. Unswitched 24 Vac power wiring can be run in the same conduit as the E-Bus cable. 2. If a Q7750A 1000-series device is located at one end of the E-Bus network, activate a termination network by placing two wires (optional jumpers) between terminals 4 and 5 and between terminals 6 and 7 (see Fig. 10). For a 2000-series device there are internal termination circuits for both a singly-terminated network topology (jumper between terminals 4 and 5 and between termninals 6 and 7) and for a doubly-terminated bus topology (jumper between terminals 3 and 5 and between terminals 6 and 8). See Fig. 11. Fig. 10. Wiring connections (1000-series E-Bus details). Fig Series E-Bus details. 3. If an XDM506 modem submodule is being used, attach the modem wiring to the appropriate terminals (9 through 18) on the mounting base. See Fig. 10. After wiring is routed, insert the tie-wraps into the holes located near the center of the mounting base. See Fig

6 Completing the Installation 1. Before mounting the Q7750A Zone Manager, turn over the device housing and remove the Philips screw located at the bottom (remove brass screw/grommet, battery and shipping tab). Separate the two parts of the device housing. See Fig. 13. NOTE: Be aware of the brass standoff located on the bottom between the circuit board and the top of the device housing. (This connects the shielding between the two parts of the device housing.) Fig. 12. Route wire and tie-wrap Fig. 13. Separate two parts of device housing (DIP switch for future use)

7 2. Attach the XD505A or the XD508 C-Bus communications submodule or the XDM506 modem submodule, which was ordered with the Q7750A, to the male and female connectors on the device circuit board. CAUTION C-Bus submodule connectors are not keyed; make sure that the male and female connections are not misaligned to prevent damage to the C-Bus submodule. 3. Press firmly down on the submodule. See Fig. 14. Reassemble the device housing by connecting the two parts of the device housing and replacing the brass screw/grommet, battery and shipping tab. 4. Verify the integrity of all the mounting base wiring. Fig. 14. Attach submodule and reassemble device housing. Secure the housing assembly to the Mounting Base 1. After all mounting base wiring is checked, carefully align the device housing over the mounting base, and push firmly on the housing device to secure it to the mounting base. Tighten the brass screw. See Fig. 15. Fig. 15. Attach device housing to mounting base

8 Install the Battery Included with the device is a 3V Lithium battery, CR 1/2 AA, VARTA number 6127 or equivalent. This battery, when new, provides one month backup of RAM and the Real Time Clock. 1. When shipped from the factory, the battery has a shipping tab between the battery positive (+) terminal and the device terminal. Remove the shipping tab during commissioning of the device. (Check and observe the polarity marked on the housing and the battery; reverse if necessary.) See Fig. 16. NOTES: When the battery is removed during a loss of input power, RAM data is lost and the device must be redownloaded. Q7750A device is located at one end of the E-Bus network, check to determine if the termination network was activated by placing two wires (optional jumpers) between the following terminal pairs. See Fig. 11: 4,5 and 6,7 (singly-terminated network) 3,5 and 6,8 (doubly-terminated network) C-Bus shield. Be sure that the C-Bus shield is attached to terminal 18, the positive lead to terminal 16, and the negative lead to terminal 17 according to job drawings. See Fig. 10. Check to see that the ferrite ring is in place on the E-Bus (see Fig. 11). NOTE: All wiring must comply with applicable electrical codes and ordinances. Refer to job or manufacturer drawings for details. Fig. 16. Remove battery shipping tab during device commissioning. CHECKOUT Step 1. Wiring Connections Inspect all wiring connections at the Q7750A terminals, and verify compliance with job drawings. If any wiring changes are required, first be sure to remove power from the controller before starting work. Pay particular attention to: 24 Vac power connections. Verify that when there are multiple Q7750A Excel 10 Zone Managers, each one has a dedicated transformer/power source, with the transformer secondary connected to terminals 1 and 2 on the mounting base, according to job drawings. See Fig. 10. E-Bus wires. Be sure that the E-Bus wires are attached to terminals 5 and 6 according to job drawings. If the Fig. 17. Q7750A Excel 10 Zone Manager LED locations

9 Table 2. Q7750A Excel 10 Zone Manager LED status information. LED No. Explanation Color LED function if On LED function if Off 1 5V (POWER) Green Power on Power off 2 Contr. (RUN) Green Software is running, watchdog is triggered Watchdog locked, software not working 3 B-PORT (send) Yellow Q7750A sends data on RS232 port* No communication 4 B-PORT (receive) Yellow Data is sent to Q7750A on the RS232 port* No communication 5 C-Bus (send) Yellow Q7750A sends data on the C-Bus * No data sent on the C-Bus 6 C-Bus (receive) Yellow Q7750A receives data from the C-Bus * No data received from the C-Bus 7 E-Bus Yellow E-Bus network activity * (see NOTE) No E-Bus network activity 8 Error Red Blinking: not configured, application loaded On: not configured, no application Valid configuration * LEDs 3 through 7 flicker with the frequency of data being transmitted or received (see NOTE). Step 2. Initial Power Up Apply power to the Q7750A. When the Q7750A receives power, the LEDs should appear in normal (uncommissioned and not downloaded) condition according to Table 2. NOTE: LED 7 is used to display E-Bus network activity. In 1000-series devices it flickers with data being transmitted or received, but in 2000-series devices it flickers only with data being received. If the status is not correct, push the reset button. Verify that the LED status is correct before proceeding. IMPORTANT The CPU reset button deletes the application program in the CPU (stored in RAM). If the reset button is pushed when the CPU contains an application, the device must be redownloaded. Step 3. Commissioning The Zone Manager CPU can be commissioned (given a C- Bus address) using an operator terminal such as the XI581 (on the PC that has the XI584 software and/or CARE installed). This operation is performed the same as for other C-Bus controllers. The following steps describe the most common procedure using the PC to commission the CPU just before downloading from the XI584. As for other C-Bus controllers, commissioning is required only after an initial power-up or if the CPU reset button was pushed. The following steps assume the Zone Manager Plant and Controller are configured in CARE (see Data File Setup section): 1. Connect the PC COM port to the Zone Manager B-port using the XW565 (or XW566) prefabricated cable. 2. Start XI584. Sign on and run XI581. Assign the controller number using the procedure for C-Bus devices (see the XI584 User's Guide, form number ). 3. Select Continue again, and select Request Download. The operator terminal should then display. Please Execute Download. 4. Select Utilities and drop down to the item File Transfer/Download. Click on All and initiate the Download. Commissioning is complete. The B-port Transmit and B-port Receive LEDs on the Zone Manager should start blinking rapidly, indicating communication between the PC and the Zone Manager. Any Download errors or connecting problems appear in the Download Results list box. A loss of communication with the B-port during downloading generates an alarm after three minutes. Press Enter and try again to download. If there is trouble establishing communication between the PC and the Zone Manager, check the following items: XW565 cable connections. That the XW565 cable is connected to the same PC COM port as selected in the CARE Download System Settings menu. IMPORTANT Carefully watch all C-Bus alarm activity following a download. Follow up as necessary on all problem alarms. Fig. 18. Connect operating device

10 Close Cover 1. Put the device cover back on. See Fig. 19. PANEL RESET When in Smoke Control Mode, panel reset is accomplished by resetting the initiating panel contact circuit or by the separate initiating/reset switch on the FSCS panel. FIELD PARAMETERS-MIN/MAX RATING W7751 B,D,F,H,RIO TRIAC Outputs: Device: Digital Inputs: E-Bus: 20 to 30 VAC at 25 ma to 1 A.24 amp max. at 25 volts 4.8 ± 0.8 VDC, 9 ma ± 1 ma not readable DATA FILE SETUP Fig. 19. Close cover. Generate the CARE data file for the Zone Manager/RIO/Excel 10 VAV2 controllers. This data file has a mix of hardware points for the necessary inputs and outputs to control fans, dampers, and other equipment. In addition to the inputs and outputs, a custom control program is written to control the outputs per the sequence. It also resets the program once the data from the operator interface indicates a normal condition for the new dedicated smoke control equipment. Wire conditions must be programmed to provide annunciation of trouble conditions. Also required for a dedicated application is a weekly time program to test control points, fans, and dampers by exercising the equipment and verifying feedback automatically during low building activity periods

11 SMOKE CONTROL CONFIGURATION Locate and configure per NFPA 92A, section UL listed annunciator/fscs panel switches have min rating of 24 V, 1/10 AMP and lamps/leds have a rating of 24 V, limited to 50 ma. Locate within same room and within 20 FT in conduit of RIO. Locate to minizmize control wiring and piping. Avoid running wires or piping through areas that have a high fire risk. Locate per UL 555S. Locate separate from and below all building exhaust fans and upstream of any prevailing winds. Exhaust to outside of building. Freeze control sensing limit must be set less than 32º F (0º C) when in Smoke Control Mode. The smoke configuration is only valid with the Excel 10 VAV and Excel 10 Remote I/O that have UUKL listing. The UUKL listed Excel 10 Controllers are W7751B2010, W7751D2016, W7751F2011, W7751H2025 and W7761A2010. Locate UL listed damper pressure/position indicator per damper installation instructions. Smoke control must be initiated by a listed fire alarm control unit or in zone automatic alarm devices and not devices located outside of the smoke control zone. Interconnecting wiring must be within 20 FT (6 m) and in conduit. Refer to smoke control fundamentals Verify AC voltage source connected to inside of main line voltage terminal block is from a UL 1481 listed uninterruptible power supply. The main line voltage terminal block maximum current draw is 0.5 AMPS. Use AC transient protection. All external field wiring leaving the room must limited to 3277 FT (999 M) and be terminated to transient protector (35 V, 290 ma max.) except C-bus field wiring communicating at 1 MHz which uses transient protector (19V, 500 ma) when field wiring leaves the zone

12 Refer to literature for device installation W7761A (RIO) W7751H (Smart VAV) W7751B,D,F (VAV) Use and-007 class II power supplies, max. loading 100VA. Install in signal system enclosure cabinet per literature. Refer to Zone Manager Installation section for LON Bus (E-Bus) connections and device installation. Per NFPA92A this equipment is to utilized as non-dedicated smoke control equipment. Status of airflow control must be provided via the airflow sensor input. POWER LIMITED POWER LIMITED THROUGH -006 POWER MODULE ACCESSORY 24V AC OUTPUT (RATED 2A) MUST BE WIRED IN ACCORDANCE WITH NFPA 70, ARTICLE 725 WHEN ROUTED WITHIN THE CABINET OR ADJACENT CABINETS AND ALSO FOR EXTERNAL FIELD WIRING. 4 ZM, R10 OR EXCEL , -004 OR -007 CONTROL POWER MODULE 24VAC OUTPUT IS INHERENTLY POWER LIMITED. THUS, ALL SOURCED POWER FROM THE EXCEL ZONE MANAGER, RI0, EXCEL 10 PANEL MOUNTED DEVICES ARE POWER LIMITED. ALL FIELD WIRING FROM THESE CONTROLLERS MEET NFPA 70, ARTICLE 725 POWER LIMITED CLASS II REQUIREMENTS VAC ZM, R10 OR EXCEL CONTROL 24VAC , -004 OR -007 DIGITAL OUTPUT RELAY POWER LIMITED ACCESSORY 24VAC NON POWER LIMITED NON POWER LIMITED 3 4 IF A SEPARATE AUXILIARY "POWER LIMITED" 24V AC POWER SOURCE IS REQUIRED, USE A CONTROL POWER MODULE ( , -004 OR -007). DEVICES MUST BE INSTALLED IN AREAS AS SHOWN. ALL CABLE MUST BE ROUTED AS SHOWN. ALL INTERNAL POWER LIMITED WIRING MUST BE SEPARATED BY 1/4 IN. (6MM) OR BARRIER FROM NON-POWER LIMITED WIRE. EXCESS WIRING MUST BE CUT, TRIMMED AND DRESSED PROPERLY TO ENSURE PROPER CLEARENCES ARE MAINTAINED. NON POWER LIMITED M14538 Fig. 20. Typical Power Limited Circuit for Excel ZM, RIO, or Excel 10 Panel Mounted Devices

13 Step 4. Troubleshooting Table 3 Troubleshooting. Problem Description Solution 5V (Power) LED not on. No power to the Zone Manager. Apply power or verify the power wiring (voltage must be 20-30V), check fuses and output from power module or transform numberer. Run LED is on. Zone Manager not operating. Software failure, do the following: Power the Zone Manager down then up. Push the CPU reset button. If the motherboard EPROM has been removed, it may have been incorrectly re-installed. Commission the Zone Manager. C-Bus Transmit LED not flashing, C-Bus Receive LED not flashing. C-Bus Transmit LED flashing, C-Bus Receive LED not flashing. C-Bus Transmit LED not flashing, C-Bus Receive LED flashing. B-port Transmit LED not flashing, B-port Receive LED not flashing. E-Bus LED not flashing. E-Bus LED flashing No C-Bus connection or no other C-Bus devices active on the bus. Zone Manager transmitting on the C-Bus but not receiving. Zone Manager receiving on the C-Bus but not transmitting. These only flash when an operator interface is communicating with the B-port. No E-Bus connection or no devices active on the E-Bus. Zone Manager transmitting or receiving on the E-Bus but other devices on the E-Bus not receiving. Disassemble the Zone Manager and check the C-Bus communication daughterboard (XD 505, XD 508) mounted on the Zone Manager motherboard and reseat it. Verify the C-Bus wiring terminations, polarity. Disassemble the Zone Manager and check the C-Bus communication daughterboard (XD 505, XD 508) mounted on the Zone Manager motherboard and reseat it. Verify the C-Bus wiring terminations, polarity. Commission the Zone Manager. Verify C-Bus wiring terminations, polarity. Cycle power. Reconnect the operator interface. Try the operator interface on another controller. Disassemble the Zone Manager and verify the E-Bus wiring. Verify E-Bus wiring. Commission the Zone Manager. Error LED on. CPU hardware/firmware failure. Do the following: Power the Zone Manager down then up. Push the CPU reset button. If the motherboard EPROM has been removed, it may have been incorrectly re-installed. Commission the Zone Manager. Battery Low message on an XBS, XI581, or XI584 Operator Terminal. Internal test of 3V lithium battery shows low power, possible failure. Remove and test the battery by putting a 5K ohm (0.25 watt, 5%) resistor across the positive and negative poles. If the voltage is less than 2.5V, replace the battery. Replace with a lithium 3V 100 ma hour, CR 1/2 AA, VARTA 6127 or equivalent

14 Home and Building Control Home and Building Control Home and Building Control Products Honeywell Inc. Honeywell Limited-Honeywell Limitee Honeywell AG Honeywell Plaza 155 Gordon Baker Road Böblinger Straβe 17 P.O. Box 524 North York, Ontario D Schönaich Minneapolis, MN M2H 3N7 Germany USA Canada Rev Printed in Germany Subject to change without notice

Excel Smart I/O Compact

Excel Smart I/O Compact HONEYWELL ECEL 5000 OPEN SYSTEM GENERAL INFORMATION LonWorks service LED LonWorks service button terminal assignment label BEFORE INSTALLATION IMPORTANT INSTALLATION INSTRUCTIONS It is recommended that

More information

4100/4120-Series and 4010ES Relay Modules Installation Instructions

4100/4120-Series and 4010ES Relay Modules Installation Instructions 4100/4120-Series and 4010ES Relay Modules Installation Instructions Introduction This publication describes the installation procedure for the relay cards listed in the following table. Model Number Description

More information

Excel 500 XCL5010 CONTROL SYSTEM

Excel 500 XCL5010 CONTROL SYSTEM Excel 500 XCL5010 CONTROL SYSTEM SPECIFICATION DATA FEATURES GENERAL The Excel 500 is a freely programmable control and monitoring system designed specifically for building management. Using the latest

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II i2920 System Controllers The Andover Continuum Infinet II i2920 System Controller is designed to meet the needs of your most demanding control and monitoring applications

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide Direct Digital VAV Controllers KMD-7001/7051 - VAV Terminal Units KMD-7002/7052 - Dual Duct VAV Units KMD-7003/7053 - Fan Induction Units 907-019-01C 1 Introduction This

More information

IQ21x Series Controllers

IQ21x Series Controllers IQ1x Series Controllers IQ1x SERIES CONTROLLERS Description Features The IQ1x series of intelligent controllers are designed for use as unitary controllers in building control systems. Full compatibility

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

M6410A, M7410F Small Individual Room Controller (IRC) Electric Linear Valve Actuators

M6410A, M7410F Small Individual Room Controller (IRC) Electric Linear Valve Actuators M60A, M70F Small Individual Room Controller (IRC) Electric Linear Valve Actuators FEATURES PRODUCT DATA M60A and M70F Underwriters Laboratories Inc. rated for plenum use (UL9-5V). Especially suitable for

More information

XL 800 Series FOR SMOKE CONTROL

XL 800 Series FOR SMOKE CONTROL XL 800 Series FOR SMOKE CONTROL HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION AND MISSIONING INSTRUCTIONS CONTENTS General... 3 Before Installation... 3 Installation... 3 Wiring... 4 XL800 Series Power

More information

Installation Instructions for UL Rev A

Installation Instructions for UL Rev A NetController II Installation Instructions for UL 864 30-3001-1008 Rev A Mounting Screw Andover Continuum Power Supply Connector Third-Party Power Supply Connector I/O Bus Connector Cover Mounting Screw

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

Separate mounting base for easy installation. Tamper resistant locking cover.

Separate mounting base for easy installation. Tamper resistant locking cover. < 3=9;>?;8736@!#" $&%(' )*' % +#, ' -/.10 +,&+ Fully compatible to all current Excel 10 and Excel 20 to 600 controllers. Low power consumption. LCD display continuously shows current space temperature,

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

4100/4120-Series Class A / Class B Zone Modules Installation Instructions

4100/4120-Series Class A / Class B Zone Modules Installation Instructions 4100/4120-Series Class A / Class B Zone Modules Installation Instructions Introduction This publication describes the installation procedure for the following modules. Model Description Required Back Box

More information

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator The i2865 and i2866 are unique, low-cost VAV box controllers that come equipped with a built-in actuator to streamline hardware

More information

FEATURES DESCRIPTION MODEL 110B. Power Supply

FEATURES DESCRIPTION MODEL 110B. Power Supply FEATURES Extends wiring distance of FT-10 LonWorks Networks. (2) channels using a single Model 110B. Up to 10 channels using (5) Model 110B. Low cost alternative to routers configured as repeaters. Wring

More information

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new Controller.

More information

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator Andover ContinuumTM b3865/866 VAV Controllers The Andover Continuum TM b3865 and b3866 are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol.

More information

BACnet. b3867 Terminal Controllers

BACnet. b3867 Terminal Controllers BACnet b3867 Terminal Controllers The Andover Continuum TM b3867 is a native BACnet controller that communicates on an RS-485 field bus as a Master device using the MS/TP BACnet protocol. 02 Features Product

More information

Installation Instructions Model PSC-17C

Installation Instructions Model PSC-17C Installation Instructions Model PSC-17C 17 Amp Power Supply INTRODUCTION The Model PSC-17C from Siemens Industry, Inc. is a high current power supply that provides the Fire Alarm system (Sprachalarmsystem

More information

SYSNet QS7700A Network Interface ControlBus Module for BCS7700

SYSNet QS7700A Network Interface ControlBus Module for BCS7700 SYSNet QS7700A Network Interface ControlBus Module for BCS7700 FEATURES PRODUCT DATA Up to six ControlBus Modules per Network Interface Unit. Remote programming of nonsafety BCS 7700 values via the ControlBus

More information

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box Infinity TCX 865,866 VAV Controller with Built-in Actuator The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box controller that comes equipped with a built-in damper

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module INSTALLATION INSTRUCTIONS CAUTION: This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Installation

More information

SLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L)

SLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L) SLX Series Document No. 997-1000 Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L) Free Programmable Controllers (SLX-PC-203, SLX-PC-300, SLX-PC-400, SLX-PC-500

More information

T7560A1036 Digital Wall Module

T7560A1036 Digital Wall Module T7560A1036 Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. T7560A1036

More information

Excel 10 W7751B,D,F VAV II Controllers

Excel 10 W7751B,D,F VAV II Controllers Excel 10 W7751B,D,F VAV II Controllers FEATURES W7751D GENERAL W7751B W7751F The W7751B,D,F are Variable Air Volume (VAV) Controllers in the Excel 10 family product line. These VAV systems provide pressure

More information

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules APPLICATION PRODUCT DATA The QS7800A Network Interface ControlBus Module allows remote monitoring and diagnostics of the 7800 SERIES

More information

7800 SERIES S7810B Multi-Drop Switch Module

7800 SERIES S7810B Multi-Drop Switch Module 7800 SERIES S7810B Multi-Drop Switch Module PRODUCT DATA APPLICATION The Honeywell 7800 SERIES is a microprocessor-based integrated burner control for automatically fired gas, oil or combination fuel single-burner

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

XT-9100 Technical Bulletin

XT-9100 Technical Bulletin System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX

More information

Andover ContinuumTM. b3850 Series Terminal Controllers

Andover ContinuumTM. b3850 Series Terminal Controllers TM b3850 Series Terminal Controllers The TM b3850 series controllers are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol. 02 Features

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001 SLATE Digital I/O Module R8001D4001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

KWIC (Kysor-Warren Interface Control) Installation and Operations Manual

KWIC (Kysor-Warren Interface Control) Installation and Operations Manual .U4 #2 C36 R38 R39 S/N U3 D37 RN33 U39 Q3 Y3 RN3. D36 R32 R3 C39 U39 Form No. 44644 Release: Rev. E Date: May 28, 999 Supersedes: Rev. D KWIC (Kysor-Warren Interface Control) Installation and Operations

More information

Redundant Master Controller Installation Instructions

Redundant Master Controller Installation Instructions Redundant Master Controller Installation Instructions Introduction This publication describes the installation procedure for the 4100-9121, 4100-9122, and 4100-9222 redundant master controller panels.

More information

P522 Signal Processor

P522 Signal Processor P522 Signal Processor INSTALLATI INSTRUCTIS Self-Check Contact Ratings: Max switching power - 60 W 125Vac Max switching voltage - 220VDC, 250Vac Max switching current - 2A DC, AC Analog Flame Signal: User

More information

SEC-H-201 Security Controller

SEC-H-201 Security Controller SEC-H-201 Security Controller INSTALLATION INSTRUCTIONS This document covers the mounting and wiring of the WEBs-AX Security Controller. It assumes that you are an engineer, technician, or service person

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II The i80 Series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. Features 0 Choose the i80 model with the

More information

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN

More information

Specification Sheet For electronically commutated motors

Specification Sheet For electronically commutated motors SC-VAV-N Specification Sheet For electronically commutated motors Used in constant pressure applications The SC-EFC is designed to control exhaust air in various building applications. The system includes

More information

Q9200A1017 OpenLink Controller

Q9200A1017 OpenLink Controller Q9200A1017 OpenLink Controller FOR LUTRON GRAFIK 6000 LIGHTING CONTROL SYSTEM SYSTEM ENGINEERING WARNING This equipment generates, uses, and can radiate radio frequency energy, and if not installed and

More information

Sylk I/O Devices APPLICATION FEATURES PRODUCT DATA

Sylk I/O Devices APPLICATION FEATURES PRODUCT DATA Sylk I/O Devices APPLICATION PRODUCT DATA The Sylk IO devices are part of the Spyder family. The three IO devices are designed to seamlessly integrate with Spyder with relay controllers using only Sylk

More information

Instruction Sheet Board Style Low Water Cutoff

Instruction Sheet Board Style Low Water Cutoff Instruction Sheet Board Style Low Water Cutoff 102-305 SUPERSEDES: REVISION E DATED December 12, 2007 #5401173-REV F PLANT ID 001-3902 US Patents 6,904,800, 7,243,540, and 7,317,993 Other Patents Pending

More information

Installation & Operation Guide

Installation & Operation Guide & Operation Guide KMD-7301/7301C Direct Digital Controller For Air Handling Applications 880-019-02C KMD 7301 and KMD 7301C Direct Digital Controller & Operation Guide Introduction This section provides

More information

H7625A, H7635A Humidity/Temperature Sensors

H7625A, H7635A Humidity/Temperature Sensors H765A, H7635A Humidity/Temperature Sensors WALL-MOUNT MODELS APPLICATION The H765A, H7635A Wall-Mount Humidity/Temperature Sensors are universal Relative Humidity transmitters that can be powered with

More information

APP 700 Technical Specification

APP 700 Technical Specification Issued: 12/12 Supersedes: 4/12 Description The APP 700 hardware series are especially designed for waste and clean water systems, both in construction and functionality. The RTUs¹ are developed to meet

More information

Expandable Power Systems

Expandable Power Systems Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.

More information

BACnet. b3810 Series Local Controllers

BACnet. b3810 Series Local Controllers BACnet b380 Series Local Controllers The Andover Continuum TM b380 series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. 0 Features Choose

More information

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7 User's Manual: Series 330I Model 330I DC-Powered Three-Way Isolator Table of Contents Page Introduction... 2 Description....2 Specifications....3 Installation.. 5 Calibration.. 6 General Maintenance...7

More information

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors H765B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors APPLICATION The H765B, H7635B, H7655B Duct-Mount and H7635C Outdoor-Mount Humidity/Temperature Sensors are universal Relative

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II i2850 Series The i2850, i2851, and i2853 controllers provide cost-effective DDC control of individual terminal units (e.g. VAV boxes, fan-powered induction units, unit ventilators,

More information

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

SuperBus 2000 Phone Interface/Voice Module Installation Instructions SuperBus 2000 Module Installation Instructions Product summary The SuperBus 2000 (PIV) Module provides phone and voice functions for the Concord, Concord 4, and Concord Express (v4) panels. The PIV module

More information

T775S Series 2000 Expansion Module

T775S Series 2000 Expansion Module T775S Series 000 Expansion Module INSTALLATION INSTRUTIONS PRODUT DESRIPTION The T775S008 Relay Expansion Module is a four relay device for use with the T775L007 and T775P00 Series 000 Electronic Stand-Alone

More information

LTEC Heat Pump DDC Controller

LTEC Heat Pump DDC Controller Document No. 09 Rev., May, 00 LTEC Heat Pump DDC Controller Product Description These instructions explain how to install or replace a LTEC (LonMark Terminal Equipment Controller) HP (Heat Pump) DDC Controller

More information

Data Sheet IQ21x Series Controllers

Data Sheet IQ21x Series Controllers Series Controllers Series Controllers Description The series of intelligent controllers are designed for use as unitary controllers in building control systems. Full compatibility with other Trend IQ controllers

More information

Excel Web XL1000B/C TABLE OF CONTENTS HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION INSTRUCTIONS

Excel Web XL1000B/C TABLE OF CONTENTS HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION INSTRUCTIONS HONEYWELL EXCEL 5000 OPEN SYSTEM Excel Web XL1000B/C INSTALLATION INSTRUCTIONS TABLE OF CONTENTS Overview of Hardware... 2 Terminal Blocks... LonWorks Interface... Ethernet Interface... RS22C Serial Interface

More information

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note *44487080* 44487080 DANGER To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board. 900- Option Board Installation Instructions 900- Specifications Inputs

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

and Network Interface Modules Installation Instructions

and Network Interface Modules Installation Instructions 4010-9817 and 4010-9821 Network Interface Modules Installation Instructions Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the

More information

rcc.1081 Installation Instructions

rcc.1081 Installation Instructions rcc.1081 Installation Instructions Table of Contents Introduction...1 Specifications...2 Mounting...3 Wiring...5 Wiring Method...7 BACnet Network Wiring...8 Setting BACnet Address...9 Setting the BACnet

More information

Excel 10 W7754K,P,Q FAN COIL UNIT CONTROLLERS

Excel 10 W7754K,P,Q FAN COIL UNIT CONTROLLERS HONEYWELL EXCEL 5000 OPEN SYSTEM GENERAL INFORMATION LonWorks service LED LonWorks service button left DIP switch (USED = wall module connected) right DIP switch (USED = terminal 11 enabled) terminal assignment

More information

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication

More information

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide Industrial Serial RS-232 to Fiber Converter KSC-200 Series Installation Guide DOC.100803-KSC-200-1- (C) 2006 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any

More information

AirTest Model CN9000 Series Sensor Controller

AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

ASI Systems ML5720A Series

ASI Systems ML5720A Series ML5720A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5720A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

Q7055B Building Network Adapters BNA-1C/2CS/2DN

Q7055B Building Network Adapters BNA-1C/2CS/2DN Q0B Building Network Adapters BNA-C/CS/DN INSTALLATION INSTRUCTIONS WARNING This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the Instructions

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

IQ-SBS LCU Series Installation Instructions

IQ-SBS LCU Series Installation Instructions Installation Instructions LCU-1 The IQ-SBS LCU-1 is a self-contained device for integrating control of facility lighting with IQ-SBS. The LCU-1 controls lighting zones, accepts input from override switches

More information

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs. This Datasheet for the IC0BBA00 Block /8Vdc Analog Inputs / Outputs. http://www.cimtecautomation.com/parts/p--ic0bba00.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-0

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs. This Datasheet for the IC660BBA026 Block 24/48Vdc Analog Current Source 6 Inputs http://www.cimtecautomation.com/parts/p-14421-ic660bba026.aspx Provides the wiring diagrams and installation guidelines

More information

PIX 535. PIX 535 Product Overview CHAPTER

PIX 535. PIX 535 Product Overview CHAPTER CHAPTER 7 PIX 535 This chapter describes the installation of the PIX 535, and includes the following sections: PIX 535 Product Overview Installing a PIX 535 PIX 535 Feature Licenses Installing Failover

More information

EP/2 Installation Instructions

EP/2 Installation Instructions 1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

EP-ELVCTL Elevator Control (NION-16C48M)

EP-ELVCTL Elevator Control (NION-16C48M) EP-ELVCTL Elevator Control (NION-16C48M) Product Installation Document This document covers the procedures and specifications for installing the above listed unit and when appropriate, information regarding

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

Installation and Hardware Guide

Installation and Hardware Guide Helios W.E.S. 1000 & 2000 (Wireless Emergency Stop) Installation and Hardware Guide E5, Version 1.3 Helios Global Tech Ltd. Contact Information Helios Global Technologies 1920 Windsor Rd Kelowna BC V1Y

More information

Security Solutions. Installation Manual Revision - April, 2004

Security Solutions. Installation Manual Revision - April, 2004 Security Solutions S321-DIN Controller Installation Manual 24-10046-18 Revision - April, 2004 1757 Tapo Canyon Road, Simi Valley, CA 93063 Tel (805) 522-5555 Fax (805) 582-7888 www.johnsoncontrols.com

More information

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS Installation Manual 1180 METRIX Experience Value 8824 Fallbrook Dr. Houston, TX 77064, USA Tel: 1-281-940-1802 After Hours Technical Assistance: 1-713-702-8805

More information

System Galaxy Hardware Manual

System Galaxy Hardware Manual System Galaxy Hardware Manual Version 2.4 June 19, 2004 System Galaxy Hardware Manual 1 Information in this document is subject to change without notice. No part of this document may be reproduced, copied,

More information

Installation Instructions Model PSX-12

Installation Instructions Model PSX-12 Installation Instructions Model PSX- Amp Power Supply Extender INTRODUCTI The SIEMENS Model PSX- is a high current power supply extender. The power supply extender works in conjunction with the PSC- power

More information

ASI Systems ML5740A Series

ASI Systems ML5740A Series ML5740A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5740A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

Installing Sentor. Hardware Installation

Installing Sentor. Hardware Installation Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs. This Datasheet for the IC0BBA00 Block /8Vdc Analog Inputs / Outputs. http://www.qualitrol.com/shop/p--ic0bba00.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-0 module.

More information

TAC I/NETTM 1284, 1280, Security Control Unit

TAC I/NETTM 1284, 1280, Security Control Unit TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring

More information

PP-8516 & PP Electronic Static Pressure Controllers and Transmitters for Cental Air Supply Systems General Instructions

PP-8516 & PP Electronic Static Pressure Controllers and Transmitters for Cental Air Supply Systems General Instructions PP-8516 & PP-8616 Electronic Static Pressure Controllers and Transmitters for Cental Air Supply Systems General Instructions Part Number PP-8516 Static Pressure Controller/Transmitter PP-8616 Static Pressure

More information

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

PIX 515/515E. PIX 515/515E Product Overview CHAPTER CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses

More information

Installation Instructions for the AUTOcard-SA System

Installation Instructions for the AUTOcard-SA System Installation Instructions for the AUTOcard-SA System IMPORTANT NOTICE The AUTOcard-SA system is a very reliable and easy to use system. However, damage could occur if it is installed incorrectly. In particular,

More information

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B OPERATIONS MANUAL n.form I/O Expander (RACK MOUNT) Document Number: 200-0009 Rev B table of contents INTRODUCTION FEATURES & CAPABILITIES 1 WIRING General I/O Configuring The System Using The System 4

More information

AI130 AIswitch Series 130 Chassis Installation Guide

AI130 AIswitch Series 130 Chassis Installation Guide AI130 AIswitch Series 130 Chassis Installation Guide Part Number QR-130 Rev 3 2007 by Kentrox, Inc. All rights reserved. Copyright 2007 by Kentrox, Inc. All Rights Reserved. The material discussed in this

More information

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS (WITH CAPACITOR CHARGER BOARD A3517-02) The process depends on Generator and System configuration. This document applies to installation of Capacitors

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE

Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE WARNINGS 1. All servicing should be performed by qualified service personnel. 2. WARNING, Battery may explode if mistreated. Do not recharge, disassemble

More information

Excel Web XL1000B/C TABLE OF CONTENTS HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION INSTRUCTIONS

Excel Web XL1000B/C TABLE OF CONTENTS HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION INSTRUCTIONS HONEYWELL EXCEL 5000 OPEN SYSTEM Excel Web XL1000B/C INSTALLATION INSTRUCTIONS TABLE OF CONTENTS Overview of Hardware... 2 Terminal Blocks... LonWorks Interface... Ethernet Interface... RS22C Serial Interface

More information