TeSys contactors. Pre-assembled. Pre-wired power connections. For connection by spring terminals. Instantaneous auxiliary contacts per contactor

Size: px
Start display at page:

Download "TeSys contactors. Pre-assembled. Pre-wired power connections. For connection by spring terminals. Instantaneous auxiliary contacts per contactor"

Transcription

1 s TeSys D, -pole changeover contactor pairs for control in category AC-, 0 A Pre-assembled. Pre-wired power connections. For connection by spring terminals. Utilisation category AC- Non-inductive loads Maximum rated operational current (θ y 0 C) Instantaneous auxiliary contacts per contactor Contactors supplied with coil Basic reference, to be completed by adding the control voltage code () Fixing () A 0 LC DT0pp 0.0 For customer assembly. Power connection by EverLink, BTR screw connectors () and control by spring terminals 0 LC DT0App () 0 LC DT0App () Separate components Auxiliary contact blocks and add-on modules: see pages / to /. () Standard control circuit voltages (for other voltages, please consult your Regional Sales Office): a.c. supply Volts LC DT0 DT0, LC DT0 DT0 0/0 Hz B D E F FE M P U Q V N R LC D000 D0 0 Hz B D E F FE M P U Q V N R S 0 Hz B E F M U Q R d.c. supply Volts LC DT0 DT0, LC DT0 DT0 (coils with integral suppression device fitted as standard) U 0.. Uc JD BD CD ED ND SD FD GD MD UD RD Low consumption Volts c LC DT0...DT0 (coils with integral suppression device fitted as standard) U 0.. Uc AL JL ZL BL EL FL ML UL For other voltages between and 0 V, see pages / to / () Clip-on mounting on mm rail AM DP or screw fixing. () BTR screws: hexagon socket head. In accordance with local electrical wiring regulations, a size insulated Allen key must be used (reference LAD ALLEN, see page /). () For these operational currents, order identical contactors and a mechanical interlock LAD CM (see page /). /

2 s Component parts for assembling reversing contactors for motor control, low-speed/high-speed starters and star-delta starters 0 LAD R For -pole reversing contactors for motor control Contactors with screw clamp terminals or connectors. Horizontally mounted, assembled by customer Description For contactors () ( identical contactors) Kits for assembly of reversing contactors b a mechanical interlock LAD V with electrical interlocking LAD V. b a set of power connections LAD V (parallel) and LAD V (reversing) b a mechanical interlock LAD V without electrical interlocking b a set of power connections LAD V (parallel) and LAD V (reversing) b a mechanical interlock LAD CM, b a set of power connections LA DA. LC D0 to D LAD RV 0.0 LC D0 to D LAD R 0.0 LC D0A to DA LAD R 0.0 LAD R LA D0 Mechanical interlocks Mechanical interlock with integral electrical interlocking Mechanical interlock without integral electrical interlocking Sets of power connections Comprising: b a set of parallel bars, b a set of reverser bars. For low-speed/high-speed starter Description Connection kit enabling reversing of low and high speed directions using a reversing contactor and a N/O + N/C main pole contactor LC D0 and D (a) LA D LC D0 and D (c) LA D LC D and D LA D 0.0 LC D0 to D LAD V 0.00 LC D0A to DA LAD CM 0.00 LC D0 and D (a) LA D0 0.0 LC D0 and D (c) LA D0 0.0 LC D0 to D with screw clamp terminals or connectors LC D0 D with spring terminal connections LAD V + LAD V LAD V + LAD V () LC D0A to DA LA DA 0. LC D0 and D (a) LA D0 0.0 LC D0 and D (c) LA D0 0.0 LC D and D LA D.0 For contactors with connection type Screw clamps or connectors LAD PVGV 0.0 Power connection module with spring terminal connections Outgoing terminal block with spring terminal connections LAD PVGV 0.0 LAD PVGV 0.0 For star-delta starter Description For contactors Mounting kit comprising: b time delay contact block LAD S (LC D0 D0), b power circuit connections (LC D0 D0), b hardware required for fixing the contactors onto the mounting plate (LC D0). LC D0 and D LAD 0.0 LC D to D LAD 0. LC D0A and D0A LAD SD 0.0 LC D0 LA D0 0.0 Equipment mounting plates LC D0, D and D LA D 0. LC D LA D 0.0 LC D0A and D0A LC D0 LA D () To order the contactors: see pages / and /. () To assemble a reversing contactor with spring terminal connections, the following components must be ordered: - mechanical interlock LAD V, - upstream power connection kit and downstream power connection kit.. Upstream power connection kit LAD V: installed in the Quickfit system with power connection module LAD. (If module LAD is not used, replace LAD V with LAD V). Downstream power connection kit LAD V: installed in the Quickfit system with outgoing terminal block LAD. (If LAD is not used, replace LAD V with LAD V). Selection : pages / to / / Characteristics : pages /0 to / Dimensions, Schemes : pages / and /

3 s Component parts for assembling changeover contactor pairs For -pole changeover contactor pairs (-phase distribution + neutral) Contactors with screw clamp terminals or connectors. Horizontally mounted, assembled by customer. Description For contactors () ( identical contactors) Kits for assembly of changeover contactor pairs b a mechanical interlock LAD V with electrical interlocking LAD V, b a set of power connections (changeover) LAD V. b a mechanical interlock LAD V without electrical interlocking, b a set of power connections (changeover) LAD V. Mechanical interlocks With integral electrical interlocking LC DT0 to DT0 with screw clamps or connectors LC DT0 to DT0 with screw clamps or connectors LAD TRV 0.0 LAD TR 0.0 LC D000 LA D LP D000 LA D LC D0 LA D 0.0 LA D0 Without integral electrical interlocking LC DT0 to DT0 with screw clamps or connectors LC DT0 to DT0 with spring terminals LAD V () 0.00 LAD V () 0.00 LC DT0A and DT0A LAD CM 0.00 LC D000 LA D0 0. LP D000 LA D0 0.0 LA D0 Sets of power connections Comprising a set of parallel bars LC DT0A and DT0A LA DA0 r 0. LC D000 LA D LP D000 LA D LC D0 LA D0.0 LC DT0 to DT0 with spring terminals LAD V 0.0 LC D000 LA D00 () LP D000 LA D00 () For -pole changeover contactor pairs Contactors with screw clamp terminals or connectors. Horizontally mounted, assembled by customer. LA D00 Description For contactors () ( identical contactors) Mechanical interlocks Without integral electrical interlocking LC D0A DA LAD RS 0. With integral electrical interlocking Sets of power connections LC D and D LA D 0.0 Comprising a set of parallel bars, LC D and D LA D 0.0 () To order the contactors: see pages / and /. () Order contact blocks LAD Np to build the electrical interlock, see page /. r Available st quarter 0. /

4 0 or See page opposite for mounting possibilities according to the contactor type /

5 s Instantaneous auxiliary contact blocks Instantaneous auxiliary contact blocks for connection by screw clamp terminals For use in normal operating environments In order to mount an LAD N on an LC D0 to D, a set of shims must be ordered separately, see page / Clip-on mounting () Number of contacts per block Composition Front LAD N 0.00 LAD N LAD N 0.00 LAD N LAD N LAD N 0.00 LAD N 0.00 LAD N LAD N LAD N 0.00 incl. N/O & N/C make before break LAD C 0.00 Side LAD N 0.00 LAD N LAD N For terminal referencing conforming to EN 00 Front on P contactors and P contactors 0 to 0 A LAD NG 0.00 LAD NG 0.00 Front on P contactors LAD NP 0.00 to 00 A LAD NP 0.00 With dust and damp protected contacts, for use in particularly harsh industrial environments Front LA DX LA DX 0.00 LA DX LA DY0 () 0.00 LA DZ LA DZ 0.00 Instantaneous auxiliary contact blocks for connection by lugs This type of connection is not possible for blocks with contact or blocks with dust and damp protected contacts. For all other instantaneous auxiliary contact blocks, add the figure to the end of the references selected above. Example: LAD N becomes LAD N. Instantaneous auxiliary contact blocks for connection by spring terminals This type of connection is not possible for LAD, LAD N with contact or blocks with dust and damp protected contacts. For all other contact blocks, add the figure to the end of the references selected above. Example: LAD N becomes LAD N. Instantaneous auxiliary contact blocks for connection by Faston connectors This type of connection is not possible for LAD, LAD N with contact or blocks with dust and damp protected contacts. For all other contact blocks, add the figure to the end of the references selected above. Example: LAD N becomes LAD N. () Maximum number of auxiliary contacts that can be fitted: Contactors Instantaneous auxiliary contacts Time delay Type Number of poles and size Side mounted Front mounted Front contact contacts contacts mounted a P LC D0 D on LH side and or or LC D0A DA on LH or on RH side and or or LC D0 and D (0/0 Hz) on each side or and or or LC D0 and D (0 or 0 Hz) on each side and and or or LC D and D on LH side and or or P LC DT0 DT0 on LH side and or or LC DT0A and DT0A on LH or on RH side and or or LC D000, D00 and D0 on each side or or or or LC D on each side and or or or c P LC D0 D or or LC D0A DA or or LC D0 and D or or or LC D and D on LH side and or or P LC DT0 DT0 or or LC DT0A and DT0A or or LC D000, D00 and D0 and or or LC D on each side and or or BC () P LC D0 D P LC DT0 DT0 () Device fitted with earth screen continuity terminals. () LC: low consumption. /

6 s Time delay auxiliary contact blocks Mechanical latch blocks LAD Tp Time delay auxiliary contact blocks for connection by screw clamp terminals Maximum number of auxiliary contact blocks that can be fitted per contactor, see page /. Sealing cover to be ordered separately, see page /. LAD T0 and LAD R0: with extended scale from 0. to 0. s. LAD S: with switching time of 0 ms ± ms between opening of the N/C contact and closing of the N/O contact. Clip-on mounting Number of contacts Time delay Type Setting range Front N/O + N/C On-delay 0. s LAD T s LAD T s LAD T s LAD S 0.00 Off-delay 0. s LAD R s LAD R 0.00 LAD Tp 0 s LAD R 0.00 Time delay auxiliary contact blocks for connection by lugs Add the figure to the end of the references selected above. Example: LAD T0 becomes LAD T0. Time delay auxiliary contact blocks for connection by spring terminals Add the figure to the end of the references selected above. Example: LAD T0 becomes LAD T0 Time delay auxiliary contact blocks for connection by Faston connectors Add the figure to the end of the references selected above. Example: LAD T0 becomes LAD T0. Mechanical latch blocks () Clip-on mounting Front Unlatching control Manual or electric For use on contactor LC D0 D (a or c) LC DT0 DT0 (a or c) Basic reference, to be completed by adding the control voltage code () LAD Kp 0.00 LC D0A DA ( P a or c) LC DT0A and DT0A ( P a or c) LAD Kp 0.00 LAD Kp LC D0 D ( P a) LC D0 and D ( P c) LC D0 ( P a) LC D0 and D ( P a) LP D0 and LC D ( P c) LA DK0p 0.00 () The mechanical latch block must not be powered up at the same time as the contactor. The duration of the control signal for the mechanical latch block and the contactor should be: u 0 ms for a contactor operating on an a.c. supply, u 0 ms for a contactor operating on a d.c. supply. Maximum impulse duration for the LAD Kp mechanical latch block: seconds. () Standard control circuit voltages (for other voltages, please consult your Regional Sales Office). Volts 0/0 Hz, c / / 0/ 0 / 0/0 / 0/ Code B C E EN K F M U Q Characteristics: pages / to / /0 Dimensions: pages / to / Schemes: pages / and /

7 s Suppressor modules LAD pp LAD RCp, LAD Vp, LAD DU, LAD Tp LA Dpp LAD DDL or LAD TpDL RC circuits (Resistor-Capacitor) Effective protection for circuits highly sensitive to "high frequency" interference. For use only in cases where the voltage is virtually sinusoidal. i.e. less than % total harmonic distortion. Voltage limited to Uc max. and oscillating frequency limited to 00 Hz max. Slight increase in drop-out time (. to times the normal time). Mounting For use with contactor () Clip-on side mounting () Clip-on front mounting () Screw fixing () Rating D0 D (P) DT0 DT0 D0A DA (P) DT0A DT0A (P) D0 D (P) D0 D (P) Type V a V c LAD RCE LAD RCG LAD RCU 0.0 LAD RCE LAD RCG LAD RCU LAD RCN 0.00 LA DAE LA DAG LA DAU LA DAN 0.0 Varistors (peak limiting) Protection provided by limiting the transient voltage to Uc max. Maximum reduction of transient voltage peaks. Slight increase in drop-out time (. to. times the normal time). Clip-on side mounting () Clip-on front mounting () Screw fixing () D0 D (P) DT0 DT0 D0A DA (P) DT0A DT0A (P) D0 D (P) D0 D (P) D0 D (P) D0 (P) LAD VE LAD VG LAD VU 0.0 LAD VE LAD VG LAD VU 0.00 LA DEE LA DEG LA DEU 0.0 LA DEE LA DEG LA DEU 0.0 Flywheel diodes No overvoltage or oscillating frequency. Increase in drop-out time ( to times the normal time). Polarised component. Clip-on side mounting () D0 D (P), DT0 DT0 0 LAD DDL 0.0 Clip-on front mounting () D0A DA (P), DT0A DT0A (P) 0 LAD DU 0.00 Screw fixing () D0 and D (P), D0 D0 (P) 0 LA DCU 0.0 Bidirectional peak limiting diodes Protection provided by limiting the transient voltage to Uc max. Maximum reduction of transient voltage peaks. Clip-on side mounting () () Clip-on front mounting () Screw fixing () D0 D (P) DT0 DT0 (P) () D0A DA (P) DT0A DT0A (P) () D0 D (P) D0 D0 (P) LAD TB 0.0 LAD TBDL 0.0 LAD TS 0.0 LAD TSDL 0.0 LAD TGDL LAD TUDL LAD TXDL 0.0 LAD TB 0.00 LAD TS 0.00 LAD TG LAD TU LAD TR 0.00 LA DBB 0.0 LA DBS 0.0 LA DBB 0.0 LA DBS 0.0 () For satisfactory protection, a suppressor module must be fitted across the coil of each contactor. () From D0 to DA and from LC DT0 to DT0A, d.c. and low consumption -pole contactors are fitted with a built-in bidirectional peak limiting diode suppressor as standard. This bidirectional peak limiting diode is removable and can therefore be replaced by the user. (See reference above). If a d.c. or low consumption contactor is used without suppression, the standard suppressor should be replaced with a blanking plug (reference LAD DL for LC D0 to D and LC DT0 to DT0; reference LAD DL for LC D0A to DA and LC DT0A to DT0A). () Clipping-on makes the electrical connection. The overall size of the contactor remains unchanged. () Mounting at the top of the contactor on coil terminals A and A. () In order to install these accessories, the existing suppression device must first be removed. /

8 See page opposite for mounting possibilities according to the contactor type /

9 s Accessories Electronic serial timer modules () b -pole contactors LC D0 to D: mounted using adapter LAD BB, to be ordered separately, see below. b -pole contactors LC D0A to DA: mounted using adapter LAD BB, to be ordered separately, see below. b -pole contactors LC D0 to D and -pole contactors LC D0 to D: mounted directly across terminals A and A of the contactor. On-delay type Operational voltage a Time delay 0 V 0 0 V LC D0 DA (P) LC D0 D (P) 0. s LA DT0U s LA DTU s LA DTU 0.00 Interface modules b -pole contactors LC D0 to D: mounted using adapter LAD BB, to be ordered separately, see below. b -pole contactors LC D0A to DA: mounted using adapter LAD BB, to be ordered separately, see below. Relay interface Operational voltage a 0 V Supply voltage E-E (c) LC D0 D (P) V LA DFB 0.00 Relay interface with "AUTO-I" manual override switch (output forced ON ), solid state type Operational voltage a 0 V 0 0 V Supply voltage E-E (c) LC D0 DA (P) LC D0 D (P) V LA DWB 0.0 Low consumption kit For use on contactors Composition LC D0A DA (P) () b a retrofit coil LAD BB. b a relay interface module LA DFB. Retrofit: coil for -pole contactor For adapting existing wiring to a new product LA DBL 0.0 For use on contactors LC D0 D Without coil suppression LAD BB 0.0 With coil suppression a V LAD BBVE 0.0 a 0 V LAD BBVG 0.0 a 0 V LAD BBVU 0.0 LC D0A A Without coil suppression LAD BB 0.0 () For V operation, the contactor must be fitted with a V coil (code Z). See pages / to /. () The kit is compatible with a coil voltage of a V to a 0 V (B to U) and c V to c 0 V (BD to UD). Characteristics: pages / to / Dimensions: pages / to / Schemes: pages / and / /

10 s (continued) Accessories LA D0 Accessories for main pole and control connections Description For use with contactors LC Sold in Connectors for cable, size ( connector) a c lots of Unit reference -pole mm DT0, DT DT0, DT LAD pole mm D0 D D0 D LA D EverLink terminal block Connectors for cables ( connectors) -pole D0A DA D0A DA LAD pole mm D, D D, D LA D 0.0 -pole mm D D LA D 0.0 LA Dp Connectors for lug type terminals ( connectors) -pole D, D D, D LA D pole D D LA D 0.0 LAD 0 Protective covers for connectors for lug type terminals -pole D0A DA D0A DA LAD D, D D, D LA D0 () 0.0 -pole D0A D0A D0A D0A LAD D, D D, D LA D LA Dp IP 0 covers for lug type terminals (for mounting with circuit-breakers GV Ppp and GV Lpp) Links for parallel connection of poles D0A DA D0A DA LAD 0.0 poles D0 D D0 D LA D 0.00 DT0, DT (P) DT0, DT (P) LA D 0.0 DT, DT0 (P) DT, DT0 (P) LAD D0A DA D0A DA LAD P 0.0 D0, D D0 LA D LA D0p poles D0 D D0 D LAD P () 0.00 D0A DA D0A DA LAD P 0.0 D0, D D0, D LA D poles DT0, DT DT0, DT LA D 0.0 D0, D D0 LA D0 0.0 Staggered coil connection D0 LA D LA D0 Control circuit take-off from main pole D0, D D0, D LA D0 0.0 D, D D, D LA D 0.0 LA D Spreaders for increasing the pole pitch to mm () For -pole contactors: set of covers, for -pole contactors: set of covers. () Separate connecting bar for connecting poles in parallel. D, D D, D GV AC0 0.0 Dimensions: pages / to / / Schemes: pages / and /

11 s (continued) Accessories GV G GV G0 GV S LA D LAD ETp Sets of contacts and arc chambers Description For contactor Sets of contacts -pole LC D LA D0 0.0 LC D LA D pole LC D0 LA D0 0.0 Arc chambers -pole LC D LA D 0. LC D LA D0 0. -pole LC D0 LA D 0.0 Power connection accessories Terminal block For supply to one or more GV G busbar sets GV G Set of A busbars for parallelling of contactors Set of A busbars for parallelling of contactors Set of S-shape busbars contactors LC D0 D or D D GV G 0.0 contactors LC D0 D or D D GV G 0.0 contactors LC D0A DA GV G 0. contactors LC D0A DA GV G () 0.0 For circuit-breakers GV Ppp and GV Lpp and contactors LC D0A DA Protection accessories Description Use Sold in lots of Miniature control circuit fuse holder GV S 0. x 0 with A-0 V fuse LA D 0.0 Sealing cover For LAD T, LAD R LA D Safety cover preventing access to the moving contact carrier LC D0 DA and DT0 DT0A LAD ET 0.0 LC D0 and D LAD ET 0.00 LC D and D LAD ET 0.00 Marking accessories Description Use Sold in lots of Sheet of blank legends, self-adhesive, x mm () Sheet of blank legends, self-adhesive, x mm () Sheet of blank legends for marking using plotter or x mm engraver Sheet of 0 blank legends for marking using plotter or x mm engraver Marker holder snap-in, x mm Marker holder snap-in, x mm Bag of 00 blank legends self-adhesive, x mm SIS Label labelling software supplied on CD-Rom Contactors (except P) LC D0 D, LAD N ( contacts), LA DK LAD N ( contacts), LAD T, LAD R, LRD Contactors (except P) LC D0 D, LAD ( contacts), LA DK Unit reference LAD 0.00 LAD 0.00 LAD 0.00 All products LAD pole contactors, LC D0...D, LA DK LC D0...DA, LC DT0...DT0A, LAD N ( contacts), LAD T, LAD R 0 LA D LAD On holder LA D LA D 0.00 Multi-language version: English, French, German, Italian, Spanish XBY U 0.0 Mounting accessories Retrofit plate for screw fixing For replacement of LC D0 to D with LC D0A to DA LAD X 0. Mounting plate Set of shims For replacement of LC F or F with LC D or D For fitting side mounting blocks LAD N on LC D0 and D LA D0 0.0 LA D 0.00 LAD X Size Allen key, insulated, 00 V For use on contactors LC D0A to LC D LAD ALLEN 0.0 () With this set of busbars, any one contactor can be supplied directly by its EverLink double cage power terminal block. The other two contactors are supplied by the busbar set. The A limitation is therefore applied to these two contactors. Example: LC DA supplied directly + contactor LC DA and contactor LC D0 A supplied via the busbar set = A. This combination is compatible with busbar set GV G. () These legends are for sticking onto the safety cover of the contactors or add-on block, if fitted. /

DB eps. See page opposite for mounting possibilities according to the contactor type EN 5/78. Version : 20.0

DB eps. See page opposite for mounting possibilities according to the contactor type EN 5/78. Version : 20.0 DB127250.eps or See page opposite for mounting possibilities according to the contactor type 5/78 References TeSys Instantaneous auxiliary contact blocks Instantaneous auxiliary contact blocks for connection

More information

TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters

TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using identical contactors 810373 Contactors with screw clamp

More information

The technical guide TeSys D

The technical guide TeSys D The technical guide TeSys D for power control & protection helping you easily select the right product Catalogue 009 Table of contents TeSys D Contactors TeSys D Contactors Pages Selection guide to Technical

More information

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) 9 A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 90

More information

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1) K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. c LC-K060ii a.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference.

More information

IEC Type Industrial Control Relays Control Relays CA2D and CA3D AC and DC Relays

IEC Type Industrial Control Relays Control Relays CA2D and CA3D AC and DC Relays AC and DC Relays AC Control Relays Type Number Composition Catalog Number Weight of contacts Instantaneous 4 4 CDN40.71/0.320 3 1 CDN31.71/0.320 CDN31 2 2 CDN.71/0.320 2 2 CDC.71/0.320 inc. 1 N/O and 1

More information

TeSys contactors From 115 to 2750 A

TeSys contactors From 115 to 2750 A Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,

More information

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO Characteristics Environment Conforming to standards IEC/EN 0947-1, 0947-5-1, NF C 3-140, VDE 00 Approvals UL, CSA, DEMKO, NEMKO, SEMKO Vertical axis Horizontal axis Operating position 180 Without derating

More information

7 - Control relays. Control relays. b k control relays

7 - Control relays. Control relays. b k control relays /0 Contents 0 - Control relays Control relays b k control relays v For a.c or d.c control circuit................................. page /4 v For d.c control circuit (low consumption).......................

More information

IEC Contactors. Auxiliary Contact Blocks GENERAL

IEC Contactors. Auxiliary Contact Blocks GENERAL IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount

More information

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton K-Line Ordering Informaiton K-Line Ordering Information Control Relays - Mounting on 35 mm DIN3 track or 4 screw direct mounting. - Screws in open ready-to-tighten position. Control Circuit Contact Configuration

More information

IEC Power Control Contactors and Contactor Assemblies

IEC Power Control Contactors and Contactor Assemblies IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

K-Line Mini - Contactors, Overload Relays and Accessories

K-Line Mini - Contactors, Overload Relays and Accessories K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information...............................................

More information

Discover TeSys U motor starters open version Starter-controller Non-reversing power bases

Discover TeSys U motor starters open version Starter-controller Non-reversing power bases Discover TeSys U motor starters open version Starter-controller Non-reversing power bases DB0 DB0 LUB, LUB LUB 0, LUB 0 Two types of bases are available, each in two versions: b LUB, LUB Standard power

More information

3RT, 3TB, 3TF Contactors for Switching Motors

3RT, 3TB, 3TF Contactors for Switching Motors RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.

More information

sirius Switching. Protecting. Starting. SIRIUS Product Overview

sirius Switching. Protecting. Starting. SIRIUS Product Overview sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during

More information

Controls Contactors and Contactor Assemblies

Controls Contactors and Contactor Assemblies Dimensional drawings RT10 contactors, -pole RT10 1 contactors, size S00 with surge suppressor, auxiliary switch block and mounted overload relay 4, 8,6 67 99 106 9 ) Lateral distance to grounded components

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Rockwell Automation Inc. 101 South nd Street Milwaukee, WI 5304 U.S.A. EU Declaration of Conformity IEC Contactors, Reversing Contactors and Accessories Name

More information

TeSys contactors 5. Selection 5. For utilisation category AC-3. Operational current and power conforming to IEC (θ y 60 C) Contactor size

TeSys contactors 5. Selection 5. For utilisation category AC-3. Operational current and power conforming to IEC (θ y 60 C) Contactor size Selection TeSys contactors For utilisation category AC- Operational current and power conforming to IEC (θ y 0 C) Contactor size Maximum operational current in AC- Rated operational power P (standard motor

More information

ontrol and rotection omponents

ontrol and rotection omponents ontrol and rotection omponents Chapter B7 Relays TeSys SK, K - For control of TeSys K contactor coils and other devices Type of product Pages TeSys SK, SKE TeSys K Relays TeSys D - For control of TeSys

More information

TeSys protection components

TeSys protection components GV ME GV ME0 Motor circuit-breakers from 0.0 to kw / 00 V, with screw clamp terminals GV ME with pushbutton control 00/ V 00 V 0 V () () () () Id ± 0 % kw ka % kw ka % kw ka % A A k 0. 0.. GV ME0 0.0 0.0

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

Solid-State Contactors

Solid-State Contactors Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

Control relays and plug-in control relays

Control relays and plug-in control relays Selection guide and plug-in control relays Applications EEquipment based on control relays control relays Mini-control relays Control a 24 660 V 2 690 V voltages c 2 440 V 2 250 V Functions Instantaneous

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

ict contactors EN 61095, IEC 1095 Interference

ict contactors EN 61095, IEC 1095 Interference ict contactors DB23399 DB669 DB06604 Country approval pictograms EN 6095, IEC 095 ict contactors are available in two versions: b Contactors without manually-operated b Contactors with manually-operated.

More information

Click 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry.

Click 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry. Click 'n' Go: SIRIUS Modular System SIRIUS Highly flexible system-based switching, protecting and starting. Answers for industry. s Everything for the electrical cabinet: SIRIUS Modular System. Contents

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

Allen-Bradley Bulletin 100 Contactors

Allen-Bradley Bulletin 100 Contactors Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression

More information

Solid-State Switching Devices

Solid-State Switching Devices Overview 3RF21 3RF20 3RF22 3RF23 SIRIUS 3RF2 solid-state switching devices Solid-state switching devices for resistive loads Solid-state relays Solid-state contactors Function modules Solid-state switching

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5

More information

onlinecomponents.com

onlinecomponents.com ccessories Field Installable Top (Front) Mount uxiliary Contact Blocks ➊ Contact Block NO NC Top mount auxiliary contact blocks snap-on to the top (front) of any contactor 4-pole auxiliary 2-pole auxiliary

More information

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors

More information

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets.

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets. 40 Series - Miniature PCB/Plug-in relays 8-10 - 12-16 40 1 & 2 Pole relay range 40.31-1 Pole 10 (3.5 mm pin pitch) 40.51-1 Pole 10 (5 mm pin pitch) 40.52-2 Pole 8 (5 mm pin pitch) PCB mount - direct or

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

Large Frame IEC Contactors

Large Frame IEC Contactors Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1 Changing Applications for Contactors There are fewer and fewer traditional large motor starting

More information

Solid-State Switching Devices

Solid-State Switching Devices Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Switching Devices for Resistive Loads /5 General data Solid-State Relays /7 General data

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Allen-Bradley 700-K40E-DJ

Allen-Bradley 700-K40E-DJ Bulletin Overview/Product Selection Bulletin Miniature Control Relays IEC compact industrial relay IPX Finger Protection Bifurcated contacts for low-level signals Optional integrated coil protection diode

More information

Load Feeders and Motor Starters for Use in the Control Cabinet

Load Feeders and Motor Starters for Use in the Control Cabinet Load Feeders and Starters for Use in the Control Cabinet rice groups G W, 4O, 30, 4, 50, 60, 4B, 4D, 4E, 4L, 4C, 4D, 4F, 47, 4N, 5K, 5K, 5N, 764, 5, 6 / Introduction SIRIUS 3RA load feeders /4 General

More information

3RV1 Circuit-Breakers

3RV1 Circuit-Breakers SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

Load Feeders and Motor Starters for Use in the Control Cabinet

Load Feeders and Motor Starters for Use in the Control Cabinet Load Feeders and Motor Starters for Use in the Control Cabinet Price groups 12W, 14O, 230, 241, 250, 260, 41B, 41D, 41E, 41L, 42C, 42D, 42F, 471, 4N1, 5K1, 5K2, 5N2, 764, 15, 16 /2 Introduction SIRIUS

More information

Load Feeders, Motor Starters and Soft Starters

Load Feeders, Motor Starters and Soft Starters Load Feeders, Motor Starters and Soft Starters Catalog Technical Information 3RA Fuseless Compact Starters /2 General data /2 - Overview /3 - Benefits 3RA1, 3RA2 Compact Starters /4 3RA1 direct-on-line

More information

Zelio Relay - plug-in relays 6

Zelio Relay - plug-in relays 6 Presentation Zelio Relay - plug-in relays or Presentation of the range The RXM miniature relay range comprises: A relays with C/O contacts, 0 A relays with C/O contacts, A relays with C/O contacts and

More information

Series CA7 Contactors

Series CA7 Contactors Series Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor line.

More information

System-based switching, protecting, starting. SIRIUS Modular System. sirius

System-based switching, protecting, starting. SIRIUS Modular System. sirius System-based switching, protecting, starting. Modular System. sirius Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors,

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that representative samples of Motor Controllers, Magnetic (See following pages for additional

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Rockwell Automation Inc. 0 South nd Street Milwaukee, WI 504 U.S.A. EU Declaration of Conformity IEC Contactors, Safety Contactors, Reversing Contactors,

More information

Miniature PCB Relays A

Miniature PCB Relays A SЕRIES Miniature PCB Relays 8-10 - 12-16 Medical and dentistry Control panels Panels for electrical distribution Toys utomation for blinds, grilles and shutters Door and gate openers Electronic circuit

More information

TeSys protection components

TeSys protection components Description, characteristics -pole electronic thermal overload, TeSys LR9D0, 0, 08, and LR9D0S DB8880.eps 7 / & 8 Description LR9D0, 0, 08 and self-powered electronic thermal overload are designed for

More information

Zelio Relay - plug-in relays

Zelio Relay - plug-in relays Presentation Presentation offer the advantages of compact size and modular design: their slim width ( mm) saves space when mounting on a rail at the back of an enclosure. RSL relays are available in two

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS. 3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA

More information

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) 030 23 030 28 039 21 039 33 039 34 Type 1 voltage surge protectors (V.S.P.) for main

More information

0 1 CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA-20 27

0 1 CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA-20 27 ccessories Field Installable C7 Top (Front) Mount uxiliary Contact Blocks Contact Block NO NC 0 2 Contact rrangement 5161 5262 with... Standard Contacts Catalog Number Price Bifurcated Contacts Catalog

More information

Allen-Bradley Drives

Allen-Bradley Drives Overview/Product Selection Bulletin IEC Industrial Safety Relay Positively Guided/Mechanically Linked as Per IEC 947-5-1 Annex L Third Party Certification By SUVA Red Cover and Mechanically Linked Contact

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions RUC industrial relays of small dimensions 135 with adaptor (V) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching

More information

System-based switching, protecting, starting. SIRIUS Modular System. sirius

System-based switching, protecting, starting. SIRIUS Modular System. sirius System-based switching, protecting, starting. Modular System. sirius Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors,

More information

XT IEC Power Control Contactors, Starters and Overload Relays

XT IEC Power Control Contactors, Starters and Overload Relays May 00 Product Family Overview 9 Contents Features and Benefits Description Page Contactors and Starters Catalog Number Selection................. Non-reversing Contactors.... Reversing Contactors........

More information

SIRIUS 3RB2 Solid-State Overload Relays

SIRIUS 3RB2 Solid-State Overload Relays SIRIUS 3RB2 Solid-State 3RB20, 3RB21 for standard applications Overview 1 2 2 $ Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and

More information

Siemens AG Highly flexible system-based switching, protecting and starting. SIRIUS Modular System. Answers for industry.

Siemens AG Highly flexible system-based switching, protecting and starting. SIRIUS Modular System. Answers for industry. Siemens AG 00 Highly flexible system-based switching, protecting and starting. SIRIUS Modular System SIRIUS Answers for industry. Everything for the electrical cabinet: SIRIUS Modular System. Press Shop

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Rockwell utomation Inc. 101 South nd Street Milwaukee, WI 504 U.S.. EU Declaration of Conformity IEC Contactors, Safety Contactors, Reversing Contactors,

More information

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays... .1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....

More information

MODULES FOR SAFETY AND MONITORING

MODULES FOR SAFETY AND MONITORING MODULES FOR SAFETY AND MONITORING Woertz AG Hofackerstrasse 47, P.O. Box 948, CH-43 Muttenz, Switzerland Tel. ++4 6 / 466 33 33, Fax ++4 6 / 46 96 06 http://www.woertz.ch Woertz-USA 5 Discovery Drive,

More information

PRODUCT SPECIFICATION. PC Board Relays. Series.

PRODUCT SPECIFICATION. PC Board Relays. Series. PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7

More information

Plug-in relays RH control relays Instantaneous (RHN) and latching (RHK)

Plug-in relays RH control relays Instantaneous (RHN) and latching (RHK) Characteristics Instantaneous (RHN) and latching (RHK) Type RHN RHK Environment Classification Standard version EDF, BV, USSR Conforming to standards Standard version IEC 255, NF C 45-25, VDE 435, BS 4794

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

Simply on. Simply off. Day and Night. sirius SWITCHING

Simply on. Simply off. Day and Night. sirius SWITCHING Simply on. Simply off. Day and Night. sirius SWITCHING SIRIUS-Funktionen im Überblick Switching Protecting Starting Monitoring and controlling Detecting Commanding and signaling Supplying Engineering SIRIUS

More information

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC Characteristics time delay relay for star-delta starter - 0.05..1 s - 24 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

Industrial Control Relays Relays and terminal module RS type

Industrial Control Relays Relays and terminal module RS type Relaysandterminal module Relays-and-terminal module RS, N A very compact, space-saving terminal module containing four or six relays with one NO contact. Features The RS series relays-and-terminal module

More information

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O Characteristics industrial timing relay - 0.3..30 s - type Qc - 24 V AC/DC, 110..240 V AC - 1C/O Main Range of product Product or component type Component name Time delay type Time delay range Sep 23,

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts Data sheet Electronic timer CT-SDS. Star-delta change-over with n/o contacts The CT-SDS. is an electronic timer from the CT-S range with Star-delta change-over and 7 time ranges. All electronic timers

More information

Crane Control Contactors and Relays

Crane Control Contactors and Relays October 8 DC Relays Type KC Heavy-Duty Mill 75 Contact Conversion The fully visible contacts have NEMA ICS--5 heavy-duty interrupting ratings and are easily converted in the field using just a screwdriver

More information

Table of Specifications

Table of Specifications Table of Specifications Midi-Contactors 3-Pole Magnetic Contactors Terminal type CC9 CC12 CC18 CC22 CC32 CC40 Screw Only Screw Only GUA1, GUA2, GUA4 GUA-1 GUA-2, GUA-4 GUA-1 GUA-2, GUA-4 GT Type Thermal

More information

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V Characteristics soft starter for asynchronous motor - ATS01-6 A - 460..480 V Price* : 152.00 GBP Main Range of product Altistart 01 Product or component type Product destination Product specific application

More information

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Max. breaking capacity

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Sprecher + Schuh 15910 International Plaza Drive Houston, TX 770 U.S.A. EU Declaration of Conformity IEC Contactors, Safety Contactors, Reversing Contactors,

More information

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview Overload Relays Siemens AG 2009 Overview 1 2 2 (1)Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and soft starters, these connecting

More information

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output

More information

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB Motors Automation Energy Transmission & Distribution Coatings DWB Molded Case Circuit Breakers DWB Molded Case Circuit Breakers Molded Case Circuit Breakers DWB Summary Presentation 0 General Characteristics

More information

TeSys model U Motor starters - open version

TeSys model U Motor starters - open version TeSys model U Motor starters - open version Catalogue May 05 Elmatik AS, Türi 9, 3 Tallinn Estonia tel. +37 650 3875 tel. +37 650 3876 fax +37 655 809 e-mail: elmatik@elmatik.ee Elmatik AS, Türi 9, 3 Tallinn

More information

Sockets and accessories for auxiliary relays

Sockets and accessories for auxiliary relays ÍNDEX Sockets and accessories for auxiliary relays User manual Sockets and accessories for auxiliary relays User manual 1 651.601.437 Rev: 8 Date: 09/08/2016 ARTECHE Power Grid, S.L. This document, including

More information

C 2 5 D N A A A

C 2 5 D N A A A Product Family Overview May 007 pplication Description These Cutler-Hammer ampere and horsepower rated devices from Eaton s electrical business are designed for service in applications such as Refrigeration,

More information

US Catalog July 2016 SMISSLINE TP

US Catalog July 2016 SMISSLINE TP US Catalog July 2016 SMISSLINE TP SMISSLINE TP modular bus system Table of contents Description 2 Building a SMISSLINE TP assembly for UL 489 and UL 508 based solutions Overview and ordering information

More information