TeSys protection components

Size: px
Start display at page:

Download "TeSys protection components"

Transcription

1 GV ME GV ME0 Motor circuit-breakers from 0.0 to kw / 00 V, with screw clamp terminals GV ME with pushbutton control 00/ V 00 V 0 V () () () () Id ± 0 % kw ka % kw ka % kw ka % A A k GV ME GV ME GV ME GV ME GV ME GV ME GV ME GV ME GV ME GV ME GV ME GV ME GV ME GV ME () GV ME 0.0 Motor circuit-breakers from 0.0 to kw / 00 V, with lus To order thermal manetic circuit-breakers with connection by lus, add the diit to the end of reference selected above. Example: GV ME0 becomes GV ME0. Thermal manetic circuit-breakers GV ME with built-in auxiliary contact block With instantaneous auxiliary contact block (composition, see pae /): b GV AE, add suffix AETQ to the motor circuit-breaker reference selected above. Example: GV ME0AETQ. b GV AE, add suffi x AETQ to the motor circuit-breaker reference selected above. Example: GV ME0AETQ. b GV AN, add suffix ANTQ to the motor circuit-breaker reference selected above. Example: GV ME0ANTQ. These circuit-breakers with built-in contact block are sold in lots of 0 units in a sinle pack. 0 () As % of Icu. () The thermal trip settin must be within the marked on the raduated knob. () Maximum ratin which can be mounted in enclosures GV MC or MP, please consult your Reional Sales Offi ce. > 00 ka. paes 0/ to 0/ paes / to / pae / 0-EN_Ver.

2 (continued) GV ME GV MEpp Motor circuit-breakers from 0.0 to kw, with sprin terminal connections GV ME () with pushbutton control 00/ V 00 V () () () Id ± 0 % kw ka % kw ka % A A k GV ME GV ME GV ME GV ME GV ME GV ME GV ME GV ME GV ME GV ME GV ME GV ME GV ME GV ME 0.0 Contact blocks Description Mountin Maximum number Instantaneous auxiliary contacts Type of contacts Sold in lots of Unit reference k Front N/O + N/C 0 GV AE 0.00 N/O + N/O 0 GV AE LH side N/O + N/C GV AN 0.00 N/O + N/O GV AN LA D Accessory Description Application Sold in lots of Unit reference k Cable end reducer For connection of conductors from to. mm 0 LA D () For connection of conductors from to. mm, the use of an LA D cable end reducer is recommended. () Maximum ratin which can be mounted in enclosures GV MC or MP, please consult your Reional Sales Offi ce () The thermal trip settin must be within the marked on the raduated knob. > 00 ka. 0 paes 0/ to 0/ paes / to / pae / 0-EN_Ver.

3 GV P, GV P and GV ME0 0 GV P0 0 GV P GV P paes 0/ to 0/ Motor circuit-breakers from 0.0 to 0 kw / 00 V 00/ V 00 V 0 V () () () () Id ± 0 % kw ka % kw ka % kw ka % A A k GV P: control by rotary knob Screw clamp terminals GV P GV P GV P GV P GV P GV P GV P GV P GV P GV P GV P GV P GV P GV P GV P 0.0 GV P: control by rotary knob Connection by EverLink BTR screw connectors () GV P GV P GV P GV P GV P GV P GV P 0.0 Connection by EverLink BTR screw connectors, for assembly with a contactor To assemble a GV P to P circuit-breaker with an LC D0A to DA contactor, it is possible to use the circuit-breaker supplied without downstream EverLink power terminal block. To order this product, add the diit to the end of the references selected above. Example: GV P becomes GV P. Connection by lus To order thermal manetic circuit-breakers with connection by lus, add the diit to the end of reference selected above. Example: GV P becomes GV P. GV ME0: pushbutton control, screw clamp terminals GV ME0 () 0.00 Motor circuit-breakers up to 0 hp / 00 V, UL 0 type E GV () To obtain a GV P motor circuit-breaker, UL 0 type E, combine: b a circuit-breaker GV PppH (except A), b and a Lare Spacin adapter GV GH. GV () To obtain a motor-circuit-breaker GV P, UL 0 type E, use the followin with the circuit-breaker: b a Lare Spacin cover GV G, b a short-circuit sinallin contact GV AM. GV with connection by lus () To obtain a motor-circuit-breaker GV P, UL 0 type E, with connection by lus, add the diit to the end of reference selected above and use the followin with the circuit-breaker: b two IP 0 covers LAD 0, b a short-circuit sinallin contact GV AM. () As % of Icu. () The thermal trip settin must be within the marked on the raduated knob. () BTR screws: hexaon socket head. Require use of an insulated Allen key, in compliance with local wirin reulations. () Recommended for use in association with a contactor. () Accessory: see pae /. () Accessories: see pae /. > 00 ka. paes / to / 0-EN_Ver.

4 GV R GV RE0 Thermal-manetic circuit-breakers GV R with screw clamp terminals Control by rocker lever 00/ V 00 V 0/0 V () () () kw ka % kw ka % kw ka % A k GV RE GV RS GV RE GV RS GV RE GV RS GV RE0.0 GV RS GV RS GV RE GV RS GV RE GV RS GV RE () As % of lcu GV RS GV RE0.0 0 GV RS0.0 0 pae 0/ pae / pae / 0-EN_Ver.

5 Thermal-manetic circuit-breakers GV RT GV RT For motors with hih peak on startin Control by rocker lever 0/ 0 V 00/ V 0 V 00 V 0 V () Id ± 0 % kw kw kw kw kw A A k GV RT GV RT GV RT GV RT GV RT GV RT GV RT GV RT GV RT GV RT GV RT 0.0 () The thermal trip settin must be within the marked on the raduated knob. 0 paes 0/ to / pae / pae / 0-EN_Ver.

6 (continued) Thermal-manetic circuit-breakers GV RT For primaries of -phase transformers Control by rocker lever Standard power ratins of thermal () Id ± 0 % 0/0 V 00/ V 0 V 00 V 0 V kw kw kw kw kw A A k GV RT0 0.0 GV RT GV RT GV RT GV RT GV RT GV RT GV RT GV RT GV RT GV RT0 0.0 Accessory () Description k Padlockable external operator (IP ) black handle, blue leend plate GV AP0 0.0 () The thermal trip settin must be within the marked on the raduated knob. () Other accessories such as mountin, cablin and markin accessories are identical to those used for GV ME motor circuit-breakers, see pae /. 0 paes 0/ to / pae / pae / 0-EN_Ver.

Discover TeSys U motor starters open version Starter-controller Non-reversing power bases

Discover TeSys U motor starters open version Starter-controller Non-reversing power bases Discover TeSys U motor starters open version Starter-controller Non-reversing power bases DB0 DB0 LUB, LUB LUB 0, LUB 0 Two types of bases are available, each in two versions: b LUB, LUB Standard power

More information

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1) K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. c LC-K060ii a.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference.

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Enclosed Starters. Operation and Protection of Motors up to 75Hp at 460Vac (100A) Motors Automation Energy Coatings USAESW09

Enclosed Starters. Operation and Protection of Motors up to 75Hp at 460Vac (100A)   Motors Automation Energy Coatings USAESW09 Motors Automation Enery Coatins Enclosed Starters Operation and Protection of Motors up to 75Hp at 460Vac (100A) Compact starter Price competitve Hih KAIC ratins Products in stock USAESW09 Combination

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

TeSys contactors. Pre-assembled. Pre-wired power connections. For connection by spring terminals. Instantaneous auxiliary contacts per contactor

TeSys contactors. Pre-assembled. Pre-wired power connections. For connection by spring terminals. Instantaneous auxiliary contacts per contactor s TeSys D, -pole changeover contactor pairs for control in category AC-, 0 A Pre-assembled. Pre-wired power connections. For connection by spring terminals. Utilisation category AC- Non-inductive loads

More information

DB eps. See page opposite for mounting possibilities according to the contactor type EN 5/78. Version : 20.0

DB eps. See page opposite for mounting possibilities according to the contactor type EN 5/78. Version : 20.0 DB127250.eps or See page opposite for mounting possibilities according to the contactor type 5/78 References TeSys Instantaneous auxiliary contact blocks Instantaneous auxiliary contact blocks for connection

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

Motor protection circuit breakers

Motor protection circuit breakers Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) 9 A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 90

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: This is to certify that representative samples of SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY MOTOR CONTROLLERS, MANUAL (See following page for additional information.)

More information

Motor protection circuit breakers

Motor protection circuit breakers R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

The technical guide TeSys D

The technical guide TeSys D The technical guide TeSys D for power control & protection helping you easily select the right product Catalogue 009 Table of contents TeSys D Contactors TeSys D Contactors Pages Selection guide to Technical

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

3RV1 Circuit-Breakers

3RV1 Circuit-Breakers SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

TeSys contactors From 115 to 2750 A

TeSys contactors From 115 to 2750 A Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,

More information

TeSys model U Motor starters - open version

TeSys model U Motor starters - open version TeSys model U Motor starters - open version Catalogue May 05 Elmatik AS, Türi 9, 3 Tallinn Estonia tel. +37 650 3875 tel. +37 650 3876 fax +37 655 809 e-mail: elmatik@elmatik.ee Elmatik AS, Türi 9, 3 Tallinn

More information

TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters

TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using identical contactors 810373 Contactors with screw clamp

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

Overvoltage Protection

Overvoltage Protection Overvoltage Protection Weidmuller has a complete line of overvoltage protection devices to effectively stop the harmful effects of electrical overvoltage and electrical noise. There is strong potential

More information

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 MKING MODERN LIVING POSSIBLE Technical brochure CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit- and overload protection of motor applications

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that representative samples of Motor Controllers, Magnetic (See following pages for additional

More information

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure MKING MODERN LIVING POSSIBLE CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M - 100 Technical brochure 2 IC.PD.C00.5.02-520B3595 Danfoss /S (R-MC/mr) 08-2009 Contents Page Circuit Breakers/

More information

MOTOR & CIRCUIT PROTECTION

MOTOR & CIRCUIT PROTECTION 2 MOTOR & CIRCUIT PROTECTION Motor Protection Circuit Breakers p2-1 Motor Protection Relays p2-13 Thermistor Protection Relay p2-18 Fuse Holders p2-20 Miniature Circuit Breakers p2-23 Residual Current

More information

Go to:

Go to: System PKZ 0 ectors 08/019 Clip plate Standard version Short version C-PKZ0 072900 C-PKZ0-K 206740 One of the clip plates is always necessary when combining a PKZM0 manual motor prr and a S(E)00 magnetic

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

File E Project 00ME December 18, 2000 REPORT COMBINATION CONTROLLERS. Siemens AG Amberg, Germany

File E Project 00ME December 18, 2000 REPORT COMBINATION CONTROLLERS. Siemens AG Amberg, Germany File E156943 Project 00ME17885 December 18, 2000 REPORT on COMBINATION CONTROLLERS Siemens AG Amberg, Germany Copyright 2000 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the

More information

IEC Contactors. Auxiliary Contact Blocks GENERAL

IEC Contactors. Auxiliary Contact Blocks GENERAL IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

194E FA 32 E P11 P11 6

194E FA 32 E P11 P11 6 Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5

More information

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

NC2 Contactor, 115~630A. 1. General. 2. Type Designation. 3. Terminal Connection. Cabling(Cu) Cable 2. Tightening torque (N m) Screw size

NC2 Contactor, 115~630A. 1. General. 2. Type Designation. 3. Terminal Connection. Cabling(Cu) Cable 2. Tightening torque (N m) Screw size R C US LISTED EU Germany Czech Ukrain South Africa USA NC Contactor, 5~30A. General. Certificates: CE, VDE, ESC, UKRTEST, RCC, UL.. Electric ratings; AC50/0Hz, up to 000V, up to 30A;.3 Application: remote

More information

sirius Switching. Protecting. Starting. SIRIUS Product Overview

sirius Switching. Protecting. Starting. SIRIUS Product Overview sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar

More information

M C. Ex d M-0... control, monitoring and signalling devices

M C. Ex d M-0... control, monitoring and signalling devices Ex d M-0... control, monitoring and signalling devices M-0 M-0 series control, monitoring and signalling devices are installed as external accessories on Cortem 'Ex d' enclosures used in any industrial

More information

NW08 to NW63 fixed circuit breakers Circuit breakers

NW08 to NW63 fixed circuit breakers Circuit breakers fixed circuit breakers Circuit breakers DB404362.eps DB404363.eps A Masterpact fixed circuit breaker is described by 4 catalogue numbers corresponding to: b the basic circuit breaker b a control unit b

More information

Multifunction

Multifunction A = 0 047 40 0 047 41 0 047 42 0 047 00 0 047 43 0 047 45 0 047 44 Dimensions see e-catalogue For controlling the switching ON or OFF of a circuit (lighting, ventilation, automation, signalling) in operation

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

UL 489 DIN rail branch circuit breakers

UL 489 DIN rail branch circuit breakers UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product

More information

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB Motors Automation Energy Transmission & Distribution Coatings DWB Molded Case Circuit Breakers DWB Molded Case Circuit Breakers Molded Case Circuit Breakers DWB Summary Presentation 0 General Characteristics

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

RiLine Compact The smart power distribution system

RiLine Compact The smart power distribution system RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine

More information

pointofsale available at your local trade outlet

pointofsale available at your local trade outlet pointofsale available at your local trade outlet pointofsale products IP65 pushbuttons Ø22.5mm Contact rating @ 240V AC 10A Resistive (AC1), 6A (AC15) PB01C PB02C PB03C PB04C PB05C PB06C PB07C PB08C PB09C

More information

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3 Wiring diagrams Content Information for reading and graphic symbols... 5/2 Wiring diagrams of the circuit-breakers... 5/3 Electrical accessories... 5/4 5/1 Information for reading and graphic symbols State

More information

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1 KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG 551 Q4 ~

More information

Miniature Circuit Breakers and Supplementary Protectors. Contents

Miniature Circuit Breakers and Supplementary Protectors. Contents . Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.

More information

Automation Molded Case Circuit Breakers IEC Style. Motors Automation Energy Transmission & Distribution Coatings

Automation Molded Case Circuit Breakers IEC Style. Motors Automation Energy Transmission & Distribution Coatings Automation Molded Case Circuit Breakers IEC Style Motors Automation Enery Transmission & Distribution Coatins www.we.net Molded Case Circuit breakers Molded Case Circuit Breakers Summary Molded Case Circuit

More information

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals Technical Data Type: KS 4401 KS 4402 KS 4403 KS 4461 KS 4404 KS 440 KS 4406 Article number * ) : 00636 00637 0063987 00614

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO Characteristics Environment Conforming to standards IEC/EN 0947-1, 0947-5-1, NF C 3-140, VDE 00 Approvals UL, CSA, DEMKO, NEMKO, SEMKO Vertical axis Horizontal axis Operating position 180 Without derating

More information

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY Issued to: Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that Auxiliary Devices representative samples of 3UF70 followed by 0 or 1 followed by 0

More information

Controls Enclosed Non-Combination Starters - PESW Series

Controls Enclosed Non-Combination Starters - PESW Series NEMA 4/4X Non Metallic Enclosure Product Features WEG offers non-reversing and non-combination NEMA-4X magnetic starter up to 75HP at 460V. Featuring components that meet IEC design standards and UL horsepower

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R) KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ Catalog Number ➍➏➑➒ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG

More information

RATINGS AND SPECIFICATIONS

RATINGS AND SPECIFICATIONS RATINGS AND SPECIFICATIONS MCCB ELECTRICAL CHARACTERISTICS TO IEC 609472, EN 609472, JIS C 121 ANN.1, AS/NZS 39472, NEMA AB1 Frame Quantity Unit Condition 125 Model E125 S125 Number of Poles 1 Type NJ

More information

Solid-State Contactors

Solid-State Contactors Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing

More information

Telemecanique TeSys Model U the ultimate starter-controller. Catalogue

Telemecanique TeSys Model U the ultimate starter-controller. Catalogue Telemecanique TeSys Model U the ultimate starter-controller Catalogue 06 0 Contents b Selection guide............................................ pages 2 and 3 b Presentation................................................pages

More information

Large Frame IEC Contactors

Large Frame IEC Contactors Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1 Changing Applications for Contactors There are fewer and fewer traditional large motor starting

More information

Bulletin 700-HL 2-Pole Terminal Block Relay

Bulletin 700-HL 2-Pole Terminal Block Relay Bulletin 700-HL 2-Pole Terminal Block Relay Bulletin 700-HL 2-Pole "Terminal Block Relay" Relay and socket assembled interface modules for high density interposing or isolation applications Screw terminal

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

Multi 9 switchgear NSA, INS, NG125

Multi 9 switchgear NSA, INS, NG125 N interpact INS 125 5 8 I. ON Installation and connection in the switchboard Multi 9 switchgear NSA, INS, NG125 051279-70% Description of device number per row (modules = 9 mm) E37025(MGA+BT) Multi 9 switchgear

More information

SACE Emax 2 Specification guide

SACE Emax 2 Specification guide SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or

More information

Issue Abbreviated BSP-Numbering system AUMA MATIC BASIC types AMB and Basic Compact (AUMA Actuators Inc.) Uncontrolled copy!

Issue Abbreviated BSP-Numbering system AUMA MATIC BASIC types AMB and Basic Compact (AUMA Actuators Inc.) Uncontrolled copy! Issue 2004-06-16 Abbreviated BSP-Numbering system AUMA MATIC BASIC types AMB and Basic Compact (AUMA Actuators Inc.) Only for internal use EWH-34 SHORT GB-01 Distributor: Uncontrolled copy! Issue 1 dated

More information

Control different load types with one device

Control different load types with one device Multipurpose Controllers DMC2 Multipurpose Modular Controller Control different load types with one device The Philips Dynalite DMC2 provides multichannel control via two interchangeable output modules.

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60 DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery

More information

K-Line Mini - Contactors, Overload Relays and Accessories

K-Line Mini - Contactors, Overload Relays and Accessories K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information...............................................

More information

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS 2 ENERGY /// TE'S CROMPTON INSTRUMENTS 3 Table of contents I. Tape Wound Measuring and Protection Current MR Series Measuring

More information

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA for ic60, iid, idpn Vigi, isw-na, RCA and ARA b The electrical auxiliaries are combined with ic60 circuit breakers, iid residual current circuit breakers, remote tripping switch disconnector isw-na, RCA

More information

Description. Installation. Power supply

Description. Installation. Power supply Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of

More information

Juliet - PK. Joystick station. business partner. Features. Design. Materials. Industrial lifting. Construction lifting.

Juliet - PK. Joystick station. business partner. Features. Design. Materials. Industrial lifting. Construction lifting. Juliet - PK Joystick station Juliet-PK joystick stations are control devices for all industrial machinery. They operate as auxiliary controllers of electrical motors through a power interface, such as

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North

More information

K1B004TLH cam switch - 1 pole A - screw mounting

K1B004TLH cam switch - 1 pole A - screw mounting Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam

More information

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays... .1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....

More information

SIRIUS 3RB2 Solid-State Overload Relays

SIRIUS 3RB2 Solid-State Overload Relays SIRIUS 3RB2 Solid-State 3RB20, 3RB21 for standard applications Overview 1 2 2 $ Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 10 11 18 19 0 04 05 Ø 8 mm Ø 1,7 mm external rubber stainless steel stainless steel glass fibre rod gasket sphere sphere 31 51 5 57 35 56 41 4 adjustable

More information

Load Feeders, Motor Starters and Soft Starters

Load Feeders, Motor Starters and Soft Starters Load Feeders, Motor Starters and Soft Starters Catalog Technical Information 3RA Fuseless Compact Starters /2 General data /2 - Overview /3 - Benefits 3RA1, 3RA2 Compact Starters /4 3RA1 direct-on-line

More information

Allen-Bradley Bulletin 100 Contactors

Allen-Bradley Bulletin 100 Contactors Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression

More information

Product Information MOBILE PLUGS AND SOCKETS ACCORDING TO STANDARDS CEI V1

Product Information MOBILE PLUGS AND SOCKETS ACCORDING TO STANDARDS CEI V1 1740 01 MOBILE SAFETY PLUGS AND SOCKETS MOBILE PLUGS AND SOCKETS ACCORDING TO STANDARDS CEI 23-50 + V1 360 opening shell for confortable wiring in a one-body structure. Ergonomic grip for practical use

More information

K1D012ULH cam changeover switch - 2-pole A - screw mounting

K1D012ULH cam changeover switch - 2-pole A - screw mounting Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing

More information