1 Hospital Grade GFCI Receptacles 2 Pole, 3 Wire Grounding 15 & 20A, 125VAC 1595-HGW SafeLock TM Protection: if critical components are damaged and ground fault protection is lost, power to receptacle is disconnected. Prevents line-load reversal miswire: no power to the face or downstream receptacles if wired incorrectly. Exceeds UL943 voltage surge requirements; survives 100x the required UL 3kA/6kV voltage surge test cycles. FSUL Listed (Federal Specification WC596). Trip indicator light (red lamp). Side or internal screw-pressure-plate back wire with #10 #14 AWG solid or stranded copper wire. Two back wire holes per terminal. Ground screw has a back wire clamp for easy installation. 1/4" thinner than competitors ; leaves more room for wires in the box. Mounting screws are shipped captive in the device and wall plate for easier installation. High-impact-resistant thermoplastic construction. Extra-long strap. Button colors match the device face. Dual-direction test and reset buttons. Class A rated GFCI. Supplied with matching TP26 nylon wall plate. Tri-drive screws. Specifications Supply Voltage Range: VAC Trip Threshold: 5± 1mA Trip Time: sec., nominal per UL Standard 20 Amp feed-thru capacity 2095-HGW Catalog Rating Number A. VAC Color Config. No. UL943 UL498 FSUL C22.2 No. 144 C22.2 No. 42 WC596 Hospital Grade 15 Amp Duplex GFCI 1595-HGI Ivory 1595-HGW White 1595-HG Brown 1595-HGGRY Gray 1595-HGRED Red 1595-HGLA Light Almond Hospital Grade GFCI Receptacles E R Hospital Grade 20 Amp Duplex GFCI 2095-HGI Ivory 5-20R 2095-HGW White 5-20R 2095-HG Brown 5-20R 2095-HGGRY Gray 5-20R 2095-HGRED Red 5-20R 2095-HGLA Light Almond 5-20R Available Spring For Configurable Solutions, see Page U-1. All devices listed on this page conform to WD-1 and WD-6.

2 Illuminated GFCI Receptacles 2 Pole, 3 Wire Grounding 15 & 20A, 125VAC Green indicator light is ON when power is available. Helps identify emergency power branch circuits. SafeLock TM Protection: if critical components are damaged and ground fault protection is lost, power to receptacle is disconnected. Prevents line-load reversal miswire: no power to the face or downstream receptacles if wired incorrectly. Exceeds UL943 voltage surge requirements; survives 100x the required UL 3kA/6kV voltage surge test cycles. FSUL Listed (Federal Specification WC596). Side or internal screw-pressure-plate back wire with #10 #14 AWG solid or stranded copper wire. Two back wire holes per terminal. Ground screw has a back wire clamp for easy installation. 1/4" thinner than competitors ; leaves more room for wires in the box. Mounting screws are shipped captive in the device and wall plate for easier installation. High-impact-resistant thermoplastic construction. Extra-long strap. Button colors match the device face. Dual-direction test and reset buttons. Class A rated GFCI. Supplied with matching TP26 nylon wall plate. Tri-drive screws WL Specifications Supply Voltage Range: VAC Trip Threshold: 5± 1mA Trip Time: sec., nominal per UL Standard 20 Amp feed-thru capacity Catalog Rating Number A. VAC Color Config. No. UL943 UL498 FSUL C22.2 No. 144 C22.2 No. 42 WC596 TradeMaster /Spec Grade Illuminated 15 Amp Duplex GFCI 1595-IL Ivory 1595-WL White 1595-L Brown 1595-LAL Light Almond 2095-HGWL Specification Grade Illuminated 20 Amp Duplex GFCI 2095-IL Ivory 5-20R 2095-WL White 5-20R 2095-L Brown 5-20R 2095-GRYL Gray 5-20R 2095-LAL Light Almond 5-20R Hospital Grade Illuminated 15 Amp Duplex GFCI 1595-HGIL Ivory 1595-HGWL White 1595-HGL Brown 1595-HGGRYL Gray 1595-HGREDL Red 1595-HGLAL Light Almond Hospital Grade Illuminated 20 Amp Duplex GFCI 2095-HGIL Ivory 5-20R 2095-HGWL White 5-20R 2095-HGL Brown 5-20R 2095-HGGRYL Gray 5-20R 2095-HGREDL Red 5-20R 2095-HGLAL Light Almond 5-20R Available Spring For Configurable Solutions, see Page U-1. All devices listed on this page conform to WD-1 and WD R E-5 Illuminated GFCI Receptacles

3 Tamper-Resistant GFCI Receptacles 2 Pole, 3 Wire Grounding 15 & 20A, 125VAC Protects children: patented, UL-Listed shutter system helps prevent improper insertion of foreign objects. SafeLock TM Protection: if critical components are damaged and ground fault protection is lost, power to receptacle is disconnected. Prevents line-load reversal miswire: no power to the face or downstream receptacles if wired incorrectly. Exceeds UL943 voltage surge requirements; survives 100x the required UL 3kA/6kV voltage surge test cycles. FSUL Listed (Federal Specification WC596). Trip indicator light (red lamp). Side or internal screw-pressure-plate back wire with #10 #14 AWG solid or stranded copper wire. Specifications Supply Voltage Range: VAC Trip Threshold: 5± 1mA Two back wire holes per terminal. Ground screw has a back wire clamp for easy installation. 1/4" thinner than competitors ; leaves more room for wires in the box. Mounting screws are shipped captive in the device and wall plate for easier installation. High-impact-resistant thermoplastic construction. Extra-long strap. Button colors match the device face. Dual-direction test and reset buttons. Class A rated GFCI. Supplied with matching TP26 nylon wall plate. Tri-drive screws. Trip Time: sec., nominal per UL Standard 20 Amp feed-thru capacity 1595-TRWCC4 Catalog Rating Number A. VAC Color Config. No. UL943 UL498 FSUL C22.2 No. 144 C22.2 No. 42 WC596 TradeMaster /Spec Grade Tamper-Resistant 15 Amp Duplex GFCI 1595-TRICC Ivory 1595-TRWCC White 1595-TRBKCC Black 1595-TRLACC Light Almond Tamper-Resistant GFCI Receptacles E HGTRW 5-20R Specification Grade Tamper-Resistant 20 Amp Duplex GFCI 2095-TRI Ivory 5-20R 2095-TRW White 5-20R 2095-TR Brown 5-20R 2095-TRGRY Gray 5-20R 2095-TRBK Black 5-20R 2095-TRRED Red 5-20R 2095-TRLA Light Almond 5-20R Hospital Grade Tamper-Resistant 15 Amp Duplex GFCI 1595-HGTRI Ivory 1595-HGTRW White 1595-HGTR Brown 1595-HGTRGRY Gray 1595-HGTRRED Red 1595-HGTRLA Light Almond Hospital Grade Tamper-Resistant 20 Amp Duplex GFCI 2095-HGTRI Ivory 5-20R 2095-HGTRW White 5-20R 2095-HGTR Brown 5-20R 2095-HGTRGRY Gray 5-20R 2095-HGTRRED Red 5-20R 2095-HGTRLA Light Almond 5-20R Available Spring For Configurable Solutions, see Page U-1. All devices listed on this page conform to WD-1 and WD-6.

4 Decorator Combination Nightlight/GFCI Receptacles 15 & 20A, 125VAC SafeLock TM Protection: if critical components are damaged and ground fault protection is lost, power to receptacle is disconnected. Sealed nightlight with high impact-resistant Lexan lens prevents tampering. Nightlight uses cooler LED illumination. Energy-efficient LED has average 20-year life expectancy, eliminating bulb replacement. Photocell turns nightlight ON in dark, OFF in daylight. Prevents line-load reversal miswire: no power to the face or downstream receptacles if wired incorrectly. Exceeds UL943 voltage surge requirements; survives 100x the required UL 3kA/6kV voltage surge test cycles. FSUL Listed (Federal Specification WC596). Trip indicator light (red lamp). Side or internal screw-pressure-plate back wire with #10 #14 AWG solid or stranded copper wire. Two back wire holes per terminal. Ground screw has a back wire clamp for easy installation. 1/4" thinner than competitors ; leaves more room for wires in the box. Mounting screws are shipped captive in the device and wall plate for easier installation. High-impact-resistant thermoplastic construction. Extra-long strap. Button colors match the device face. Dual-direction test and reset buttons. Class A rated GFCI. Supplied with matching TP26 nylon wall plate. Tri-drive screws NTLWCC4 Specifications Supply Voltage Range: VAC Trip Threshold: 5± 1mA Trip Time: sec., nominal per UL Standard 20 Amp feed-thru capacity Light Catalog Rating Output in Config. Number A. VAC 1' FCD* Color No. Combination Nightlight/GFCI 1595-NTLICC Ivory 1595-NTLWCC White 1595-NTLBKCC Black 1595-NTLLACC Light Almond 2095-NTLI Ivory 5-20R 2095-NTLW White 5-20R 2095-NTLGRY Gray 5-20R 2095-NTLRED Red 5-20R 2095-NTLLA Light Almond 5-20R Hospital Grade Combination Nightlight/GFCI 1595-HGNTLI Ivory 1595-HGNTLW White 1595-HGNTL Brown 1595-HGNTLGRY Gray 1595-HGNTLRED Red 1595-HGNTLLA Light Almond 2095-HGNTLI Ivory 5-20R 2095-HGNTLW White 5-20R 2095-HGNTL Brown 5-20R 2095-HGNTLGRY Gray 5-20R 2095-HGNTLRED Red 5-20R 2095-HGNTLLA Light Almond 5-20R *FCD = Foot Candle Distance, 1 Lumen = 1 FCD. See Page U-42 for more information. Available Spring All devices listed on this page conform to WD-1 and WD-6. UL943 UL498 FSUL C22.2 No. 144 C22.2 No. 42 WC HGNTLW 5-20R E-9 Decorator Combination GFCI Receptacles

5 Portables Applications All Pass & Seymour/Legrand Portable meet OSHA and NEC requirements to provide ground fault protection for personnel utilizing temporary power during construction, remodeling, maintenance, repair and demolition. Can be used with power tools, high-pressure power washers, wet vacuums, and grounds keeping equipment. Also used on spas, hot tubs, vending machines, and portable signs to provide ground fault protection. Open Neutral Protection All Pass & Seymour/Legrand portable have an open neutral relay that automatically cuts off power to the line (hot) conductor of the device in the event that the neutral wire preceding the GFCI becomes severed. For example, if your portable GFCI were plugged into an extension cord that was supplying the power and the neutral conductor on that extension cord was accidentally cut (as can happen on a job site), the open neutral relay would shut off power to the hot conductor. This provides an additional level of safety from possible ground faults. Manual Reset GFCI Requires the GFCI to be manually set for use by pressing the reset button upon plug in and after loss of primary power (power failure or unplugging the device). Must be manually reset after a ground fault condition. Ideal for applications where operator injury might occur if equipment were to restart after a power failure. Typical equipment includes power drills, saws, lathes, and grinders. Automatic Reset GFCI Automatically energizes or sets the GFCI for use upon plug in and after the loss of primary power (power failure or unplugging the device). After a ground fault condition, must be reset by pushing the reset button. This feature eliminates the need for unit to be reset each time it is plugged in or powered up. Ideal for equipment intended for continuous use where a temporary power failure is likely and undesirable. Examples are pumps, pressure washers, portable signs, or lighting and engine heaters. 4.00" 2.00" & Specifications Durable polycarbonate case withstands hard use. Open neutral protection. Supply Voltage Range: VAC Operating Temperature: -35 C (-30 F) to +66 C (150 F) Trip Time:.025 sec., nominal per UL Standard Trip Threshold: 5 ±1mA Cord Grip Range:.30"-.46" 1594-CMM Catalog Rating Right Angle Number Reset A. VAC Config. No. GFCI Plug Right Angle Plug Portable GFCI UL943 UL498 C22.2 No CMM Manual P User attachable 1594-CMA Automatic P User attachable Portables E-10 All devices listed on this page conform to WD-1 and WD-6.

6 Portables & Specifications Durable polycarbonate case withstands hard use. In-line has power indicator light that is on when power is available. Open neutral protection. Optional Turnlok plugs and connectors prevent accidental disconnection. Optional tri-cord connector handles up to three loads. Supply Voltage Range: VAC Operating Temperature: -35 C (-30 F) to +66 C (150 F) Trip Time:.025 sec., nominal per UL Standard Trip Threshold: 5 ±1mA 27.75" 9.6" 11.75" Catalog Rating Config. Number Description Reset A. VAC No. Plug Conn. 15 Amp In-Line Portable GFCI UL943 UL498 C22.2 No PC6M 6' cord, Manual P/R 1594-PC2M 2' cord, Manual P/R 1594-PC2A 2' cord, Auto P/R 1594-TC2M 2' cord with Manual P/R tri-cord connector 1594-TC2A 2' cord with Auto P/R tri-cord connector 1594-TL2M 2' cord, Turnlok Manual L5-15P/R 1594-TL2A 2' cord, Turnlok Auto L5-15P/R 20 Amp In-Line Portable GFCI 2094-PC2A 2' cord, Auto P/R 2094-PC2M 2' cord, Manual P/R 2094-TL2A 2' cord, Turnlok Auto L5-20P/R 2094-TL2M 2' cord, Turnlok Manual L5-20P/R 26.75" 26.00" 1594-PC2A 10.25" 10.10" 1594-TC2A 7.6" 12.00" Catalog Rating Config. Number Description Reset A. VAC No. Plug Conn. UL943 UL498 C22.2 No. 144 Cord Set Portable GFCI 1594-CS1M 1' cord Manual P/R with connector 1594-CS1A 1' cord Automatic P/R with connector Note: Custom Portable available in various cord lengths, and special plugs and connectors. Contact Customer Support at " 1594-TL2M 8.75" 9.75" All devices listed on this page conform to WD-1 and WD CS1M 1594-CS1A 9.8" 13.60" 2094-PC2A E-11 Portables

7 Decorator Devices 3.31" 1.290" Decorator Devices TradeMaster Decorator Receptacles 15A, 125V n High impact-resistant thermoplastic construction. n Extra-long strap. n Quickloop wire looping aid. n Long-term blade retention. n Tri-drive screws. n Extra-large circuit break-off tabs. n Side-access push wire release. n Ultrasonic welding of face to back body. n Side wire accepts #12 #14 AWG solid. n Push wire accepts #14 AWG solid only. n Self-grounding models provide automatic ground clip. Rating Catalog Number A. V. Color Config. No. UL498 C " 885I Decorator Duplex Receptacles 885I Ivory 885W White Brown 885BK Black 885LA Light Almond Self-Grounding Decorator Duplex Receptacles 885SI Ivory 885SW White 885SLA Light Almond For Configurable Solutions, see Page U " 3.31" n Longer steel straps than competitive devices, still fits under a standard wall plate. n High-impact thermoplastic face and back body eliminate cracks, breaks and callbacks. n Ultrasonic welding of face to back body. n Patented design provides better plug retention. n External screw-pressure-plate back wire on all four terminal screws and ground screw eliminates wrapping. n Accepts #12 and #14 stranded and solid wire. n Break-off tabs that are big enough to grab hold of even if the contact screws are backed-out. Scored deeper, for fast, clean breaks every time. n All four contact screws and the ground screw are backed-out. n All screws are tri-drive. TradeMaster Receptacles E " TM885W 2 Pole, 3 Wire Rating Catalog Number A. V. Color Config. No. Decorator Duplex Receptacles with Pressure Plates TM885I Ivory TM885W White TM Brown TM885GRY Gray TM885BK Black TM885LA Light Almond Decorator Duplex Receptacles with Pressure Plates Self-Grounding TM885SI Ivory TM885SW White TM885SLA Light Almond Decorator Duplex Receptacles with Pressure Plates Bulk Pack of 150 TM885I Ivory TM885W White TM885LA Light Almond UL498 All devices listed on this page conform to WD-1 and WD-6.

8 Decorator Devices TradeMaster Decorator Hallway Lights & Combination Devices n Impact-resistant face and body. n GE Lexan high impact-resistant lens. n External screw-pressure-plate back and side wired. Accepts #12 and #14 AWG. n Ground screw position under the end of the strap minimizes the risk of contact. n Energy-efficient LED has average 20-year life expectancy: eliminates bulb replacement. n Sensor automatically turns light ON in the dark. n Increased light output for better illumination. n Light sensor for enhanced sensitivity. 1.59" 1.29" Decorator Devices Catalog Rating Light Output Number A. VAC In 1' FCD* Color UL1598 TradeMaster Decorator Full Hallway Light TMHWLCC Clear Enhanced Decorator Full Hallway Light with Light Sensor TMHWLECC Clear Enhanced Decorator Full Hallway Light without Light Sensor TMHWLENSCC Clear Full Hallway Decorator Light for use with P&S Metal Louver Plates** TMHWLLOUVCC Clear *FCD = Foot Candle Distance. 1 Lumen = 1 FCD. See Page U-55 for more information. **For Louver Plates, see Page S-20. TMHWLCC 3.281" 2.60" 1.59" 1.29" 3.281" 2.60" Catalog Rating Light Output Number A. VAC In 1 FCD* Color Config. No. UL498 TradeMaster Decorator Hallway Light & Single Receptacle TM8HWLICC / Ivory TM8HWLWCC / White TM8HWLBKCC / Black TM8HWLCC / Brown TM8HWLLACC / Light Almond Enhanced Decorator Hallway Light & Single Receptacle TM8HWLEICC / Ivory TM8HWLEWCC / White TM8HWLELACC / Light Almond *FCD = Foot Candle Distance. 1 Lumen = 1 FCD. See Page U-55 for more information. 2 Pole, 3 Wire For complete line of Decorator Combination Devices and Hallway Lights, see Pages E-7 E-11, E-17, E-18, E-21, E-30, E-36, and E-72. All devices listed on this page conform to WD-1 and WD-6. 3rd Party Compliance TMHWLECC 1.59" 1.29" 3.281" 2.60" TM8HWLWCC 1.59" 1.29" 3.281" 2.60" TM8HWLEWCC4 E-21 Hallway Lights & Combination Devices

GFCIs. Index. GFCIs. P&S innovations from the first GFCI receptacle to SafeLock Protection. E-1

GFCIs. Index. GFCIs. P&S innovations from the first GFCI receptacle to SafeLock Protection. E-1 P&S innovations from the first GFCI receptacle to SafeLock Protection. In 1971, we introduced the first GFCI receptacle. Soon, our invention was preventing injuries and saving lives throughout North America.

More information

Healthcare Solutions P&S. designed to be better. Dependable performance and safety.

Healthcare Solutions P&S. designed to be better. Dependable performance and safety. P&S Healthcare Solutions Dependable performance and safety. designed to be better. Quality Hospital grade devices you can count on. Auto-ground clip ensures ground connection. One-piece brass mounting

More information

Description GFCI HG ST DUPLEX 20A 125V BR Long Description GFCI HG ST Duplex 20A 125V BR

Description GFCI HG ST DUPLEX 20A 125V BR Long Description GFCI HG ST Duplex 20A 125V BR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 SGFH20B Gfci HG ST Duplex 20A 125V BR Eaton Wiring Devices Catalog Number SGFH20B Manufacturer Eaton Wiring Devices Description

More information

Hospital Grade devices Straight Blade Plugs & Connectors 2 Pole, 3 Wire Grounding 15 & 20A, 125 & 250V

Hospital Grade devices Straight Blade Plugs & Connectors 2 Pole, 3 Wire Grounding 15 & 20A, 125 & 250V Hospital Grade devices Straight Blade Plugs & Connectors 2 Pole, 3 Wire Grounding 15 & 20A, 125 & 250V 1.350".77" 2.130" 1.530" PS5266XHG PS5269XHG PS5266HGAN PS8115 PS8119 Features rugged two-piece cord

More information

SECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 26 27 26 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Combo 2 Port Usb Receptacle 15A 125V Iv 15A 125V 2P IV USB RECEPT COMBO 2 PORT USB RECEPTACLE 15A 125V IV

Combo 2 Port Usb Receptacle 15A 125V Iv 15A 125V 2P IV USB RECEPT COMBO 2 PORT USB RECEPTACLE 15A 125V IV 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com TR7740VB0X 15A 125V 2P Iv Usb Recept Cooper Wiring Devices Catalog Number Manufacturer

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

SECTION WIRING DEVICES

SECTION WIRING DEVICES SECTION 16141 WIRING DEVICES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION SECTION. EATON 2016 Arrow Hart Buyers Guide

SECTION SECTION.     EATON 2016 Arrow Hart Buyers Guide 1 EATON 2016 Arrow Hart Buyers Guide www.arrowhart.com /arrowhart Hospital Grade Devices Table of contents Hospital grade families -7 ArrowLink modular connectors -8, -9 Tamper resistant device options

More information

New ways to increase profit margins.

New ways to increase profit margins. P&S PlugTail Wiring Devices New devices. New upgrade opportunities. New ways to increase profit margins. P&S PlugTail Wiring Devices the most complete line to keep you profitable on any commercial job.

More information

New ways to increase profit margins.

New ways to increase profit margins. P&S PlugTail Wiring Devices New devices. New upgrade opportunities. New ways to increase profit margins. complete line ble on any commercial job. Introducing P&S PlugTail Sensors and Surge Protection Devices.

More information

SECTION WIRING DEVICES

SECTION WIRING DEVICES PART 1 - GENERAL... 1 1.1 RELATED DOCUMENTS... 1 1.2 SUMMARY... 1 1.3 DEFINITIONS... 1 1.4 REFERENCES... 2 1.5 SUBMITTALS... 2 1.6 QUALITY ASSURANCE... 2 1.7 COORDINATION... 2 PART 2 - PRODUCTS... 2 2.1

More information

Emery County Senior Center Green River 06/07

Emery County Senior Center Green River 06/07 SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

For (2) Single Receptacles: dia. Hole Standard Depth

For (2) Single Receptacles: dia. Hole Standard Depth 6000 Series - Portable Outlet Boxes 6002 NOTICE: The NEC restricts the use of metal job boxes as temporary power cords 6000 6000 Series Portable Outlet Boxes Rugged and durable, these outlet boxes are

More information

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE 1. Circuit Breaker Tripping 2. Circuit Overload 3. Short Circuit 4. Ground Fault 5. Ground Fault Circuit Interrupter (GFCI) Tripping SAFETY PRECAUTIONS Basic

More information

ArrowLink Modular Wiring Devices. Devices which make installation faster, easier, more consistent and more cost effective.

ArrowLink Modular Wiring Devices. Devices which make installation faster, easier, more consistent and more cost effective. Modular iring Devices Devices which make installation faster, easier, more consistent and more cost effective. Modular iring Devices The most complete device installation solution. Modular iring Devices

More information

FDS / FDS-R / FDS-PS

FDS / FDS-R / FDS-PS FDS / FDS-R / FDS-PS USER MANUAL For use with 120V 60Hz input. Output is 120V 60Hz at 5amps 600W MAX. switched. ETL LISTED Conforms to UL STD 1241 3091594 79-15167-00 REV. A www.fiberstars.com Page 1 of

More information

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section. SECTION 16140 WIRING DEVICES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and Division 1 Specification Sections, apply to this Section. 1.02 SUMMARY A. This Section includes receptacles, connectors,

More information

CATALOG. more style. more function. more radiant. Legrand, North America

CATALOG. more style. more function. more radiant. Legrand, North America CATALOG Legrand, North America 60 Woodlawn Street West Hartford, CT 06110 1.877.BY.LEGRAND (295.3472) www.legrand.us/radiant 570 Applewood Crescent Vaughan, Ontario L4K 4B4 905.738.9195 www.legrand.ca/radiant

More information

Surge Protection (TVSS)

Surge Protection (TVSS) Surge Protection K Hospital rade SurgeBloc TVSS K-1 Hospital rade Receptacles with LED Indicators K-2 Hospital rade Receptacles with LED Indicators and Switched Alarms K-3 Commercial Specification rade

More information

Steel Plugmold Multioutlet Systems

Steel Plugmold Multioutlet Systems Steel Plugmold Multioutlet Systems Steel Plugmold Multioutlet Systems are available in a wide range of lengths and finishes to provide a versatile solution for many applications. Options include versions

More information

Recp HG Ig SGL 20A 125V 2P3W STR B&S or

Recp HG Ig SGL 20A 125V 2P3W STR B&S or 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 IG8310RN Recp HG Ig SGL 20A 125V 2P3W STR B&S or Catalog Number Manufacturer Weight per unit Product Category IG8310RN

More information

SureTest Model ST 1D Instructions

SureTest Model ST 1D Instructions #61-152 #61-153 SureTest Model ST 1D Instructions Introduction The SureTest family of circuit analyzers identify problems common to electrical circuits quickly, easily and accurately. They have a patented

More information

Duplex Convenience Receptacles

Duplex Convenience Receptacles PDHonline Course E292 (2 PDH) Duplex Convenience Receptacles Instructor: David A. Snyder, PE 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088 www.pdhonline.org

More information

Posi-Lok Plugs and Panels

Posi-Lok Plugs and Panels THE SAFEST ELECTRICAL SYSTEM FOR HIGH AMPERAGE CONNECTIONS, POSI-LOK IS PART OF THE CAM-LOK FAMILY OF CONNECTORS. THE GROUND ALWAYS MAKES FIRST AND BREAKS LAST ALL POSI-LOK SYSTEMS ARE UL LISTED AND CSA

More information

Instruction / Installation Sheet DataComm Electronics WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet

Instruction / Installation Sheet DataComm Electronics WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet Instruction / Installation Sheet DataComm Electronics 45-0024-WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet DataComm Electronics, Inc. 6349 Peachtree Street Norcross, GA 30071-1725

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions.

More information

ORIGINAL CABLE PLATES

ORIGINAL CABLE PLATES Since 1998, DataComm Electronics has been pioneering innovative solutions for structured wiring. Industry-wide, we are known as the manufacturer who listens to customers, delivering the reliable and affordable

More information

SNAPConnect Devices. Savings and Productivity Are Just a SNAP Away. Hospital Grade. Specification Grade Receptacles. Split Circuit

SNAPConnect Devices. Savings and Productivity Are Just a SNAP Away. Hospital Grade. Specification Grade Receptacles. Split Circuit SNAPConnect Devices Savings and Productivity Are Just a SNAP Away Hospital Grade Specification Grade Receptacles Split Circuit Style Line Decorator Single Receptacles GFCIs USB Charging Receptacles Permanently

More information

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data: Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

Convenience Outlets and Receptacles. Quick Guide to Snap-In Outlets and Plugs

Convenience Outlets and Receptacles. Quick Guide to Snap-In Outlets and Plugs SETION K table of contents onvenience Outlets and Receptacles Snap-In onvenience Outlets 2-Pole, 3-ire rounding.................................. K2-K7 rounding Outlet with rounding Lead...............

More information

Switch rated plugs and receptacles with NEMA 4X protection

Switch rated plugs and receptacles with NEMA 4X protection DSN Features and Ratings p. 22 DSN20 p. 23 DSN30 p. 25 DSN60 p. 27 Spare parts p. 29 Dimensions p. 31 21 Switch rated plugs and receptacles with NEMA 4X protection DSN Series products are switch and hp

More information

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters Yellow Section Capacitor Sockets and Monitors, Temporary Service Adapters, Quick Set/Gen Set, Temporary Load Center, TSA, Transformer Load Management CAPACITOR CONTROLLER SOCKET Four - Six Jaws Wire Lugs

More information

Dimmers & Fan Speed Controls

Dimmers & Fan Speed Controls Dimmers & Fan Speed Controls Today s home and business owners want optimum control of their electrical systems. P&S Dimmers & Fan Speed Controls provide that control along with aesthetics, durability,

More information

Safety Control Relay Product Catalog

Safety Control Relay Product Catalog Product Catalog Wall Mount for use with Safety Mats Safety Edges Safety Bumpers Safety Sensors 2 wire Safety Sensors 4 wire DIN Rail Mount Intrinsically Safe Explosion Proof Wall Mount Introduction The

More information

Principal LED Street Stik Fluorescent Bulb Replacements

Principal LED Street Stik Fluorescent Bulb Replacements Principal LED Street Stik Fluorescent Bulb Replacements LED Retrofit Guide (PL-RT1-001) WARNING Installation must only be performed by a licensed electrician. To prevent death, injury or damage to property

More information

SECTION WIRING DEVICES

SECTION WIRING DEVICES SECTION 26 27 26 WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Receptacles, receptacles with integral GFCI, and associated device plates. 2. Twist-locking receptacles.

More information

Ground Fault Products Straight Blade Automatic and Manual Set Portable GFCI Line Cords Features and Benefits

Ground Fault Products Straight Blade Automatic and Manual Set Portable GFCI Line Cords Features and Benefits Ground Fault Products Straight Blade Automatic and Manual Set Portable GFCI Line Cords Features and Benefits Circuit Guard Set GFCI Line Cord Portable GFCI Line Cords provide ground fault protection both

More information

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE www.osram-americas.com S90655 OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE OSRAM ReliaSys TM Outdoor LED Retrofit Kit is an alternative to high-intensity discharge (HID) lamps up to 400W (MH)

More information

Convenience Outlets and Receptacles. Quick Guide to Snap-In Outlets and Plugs

Convenience Outlets and Receptacles. Quick Guide to Snap-In Outlets and Plugs SETION K table of contents KS ETION *UL Recognized omponent onvenience Outlets and Receptacles Snap-In onvenience Outlets 2-Pole, 3-ire rounding.................................. K2-K7 rounding Outlet

More information

Self-Adjusting Ultrasonic Wall Switch Sensor

Self-Adjusting Ultrasonic Wall Switch Sensor -1 06.09.05 Self-Adjusting Ultrasonic Switch Sensor The ultrasonic offers a direct and quick replacement of wall switches for stand-alone line voltage switching of small spaces. The intelligent, continuously

More information

ASCO SERIES 300 Manual Transfer Switch Solutions

ASCO SERIES 300 Manual Transfer Switch Solutions ASCO SERIES 300 Manual Transfer Switch Solutions When power fails, businesses suffer. For some organizations, a permanent generator is too costly. Instead, permanent means for quickly connecting a portable

More information

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017 APPLICATION CONTROL GUIDELINES IntelliROL Power Supply PN 1176718 Revision Date: March 15, 2017 Table of Contents List of Tables...3 TGW Safety Recommendation...4 Warnings and Safety Instructions...5 Introduction...6

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

Connecting Power and Ground

Connecting Power and Ground This chapter explains how to connect the power and ground for NCS 2006 shelf. The sections are: Power and Ground Description, page 1 NTP-L12 Installing Power and Ground to the NCS 2006 Shelf, page 2 Power

More information

MBE Mounts and Adapters

MBE Mounts and Adapters MBE Mounts and Adapters MBE Series en Installation Guide MBE Mounts and Adapters Table of Contents en 3 Table of Contents 1 Important safety instructions 4 2 MBE Series Mounts and Adapters 6 2.1 Unpacking

More information

Technical data: Pin Spacing

Technical data: Pin Spacing 282 Female Connectors, Double-Row Pin Spacing: 3.5 mm Universal connection for all conductor types Unique, compact, double-row connector system for conductor cross sections up to 1.5 mm 2 High-density,

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

Compact plugs and receptacles standard or high temperature rated

Compact plugs and receptacles standard or high temperature rated PN Features and Ratings p. 118 PN20 p. 119 PN20 High Temp p. 121 Spare parts p. 123 Dimensions p. 125 Compact plugs and receptacles standard or high temperature rated PN Series plugs and receptacles offer

More information

R-LB R-LX Series Installation, Operation & Maintenance Manual

R-LB R-LX Series Installation, Operation & Maintenance Manual Installation, Operation & Maintenance Manual WARNINGS Safety First Hazardous Voltage & Shock Hazard Only qualified licensed electricians should install or service SPDs Hazardous voltages exist within SPDs

More information

Modular Wiring Devices. A revolutionary line of wiring devices engineered for fast and easy installation. lev-lok

Modular Wiring Devices. A revolutionary line of wiring devices engineered for fast and easy installation. lev-lok Modular Wiring Devices A revolutionary line of wiring devices engineered for fast and easy installation lev-lok Simple, Secure Installation Install Wiring Module All modules have a Circuit ID Label for

More information

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing MODEL NUMBER: ISOBAR6 Highlights 6 NEMA 5-15R outlets in exclusive isolated filter banks Network-grade

More information

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors Connector System for Fluorescent Lighting Fixtures Connectors for In-Line Mounting of Fluorescent Lighting Fixtures Fully Polarized Connectors Luminaire Disconnect Connectors Pluggable Lighting Connectors

More information

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all

More information

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...

More information

Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing

Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing MODEL NUMBER: ISOBAR8ULTRA Highlights 8 NEMA 5-15R outlets in exclusive isolated filter banks

More information

Advantage Series Switch-Rated IEC Pin & Sleeve. Highest Performing IEC Pin & Sleeve Connections for the Most Demanding Environments

Advantage Series Switch-Rated IEC Pin & Sleeve. Highest Performing IEC Pin & Sleeve Connections for the Most Demanding Environments Advantage Series Switch-Rated IEC Pin & Sleeve Highest Performing IEC Pin & Sleeve Connections for the Most Demanding Environments The Evolution of Pin & Sleeve Hubbell is the Only IEC 60309 Pin & Sleeve

More information

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com 91001W 1000W Rotary Dimmer Pass & Seymour/Legrand Catalog Number Manufacturer Description

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

* Optional TLPC shown. Mounting for Square Pole ORDERING INFORMATION 72W 108W 141W 188W 108LED 141LED 188LED. DM 0-10V Dimming. (Std.

* Optional TLPC shown. Mounting for Square Pole ORDERING INFORMATION 72W 108W 141W 188W 108LED 141LED 188LED. DM 0-10V Dimming. (Std. Revised: 11.1.16 LED AREA / PARKING / STREET LIGHT LAP-G APPLICATION For all applications in site, area, and general lighting requiring high uniformity, excellent vertical light distribution, reduced offsite

More information

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

BuildingName The Description of the Project P DOCUMENTS

BuildingName The Description of the Project P DOCUMENTS P00000000 0000 DOCUMENTS ARCHITECTURE, ENGINEERING AND CONSTRUCTION ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

The Leviton Load Center THE FUTURE MADE CURRENT

The Leviton Load Center THE FUTURE MADE CURRENT The Leviton Load Center THE FUTURE MADE CURRENT Raising the Bar Again For over 110 years, Leviton has cultivated a rich tradition of safety and innovation, developing electrical products that set the

More information

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing MODEL NUMBER: ISOBAR4ULTRA Highlights 4 NEMA 5-15R outlets in exclusive isolated filter banks

More information

THE ARIA. LED AREA LIGHT. eran industrial. ARL SERIES

THE ARIA. LED AREA LIGHT. eran industrial. ARL SERIES AREA LIGHT eran industrial. ARL SERIES AREA LIGHTS THE SUPERIOR ARL SERIES ARL 460 120W 100W 65W ARL 480 250W 200W 150W ARL 460 380W 300W WE CONTINUE TO BRING ADVANCED TECHNOLOGY TO THE LIGHTING INDUSTRY.

More information

The Leviton Load Center THE FUTURE MADE CURRENT

The Leviton Load Center THE FUTURE MADE CURRENT The Leviton Load Center THE FUTURE MADE CURRENT Raising the Bar Again For over 110 years, Leviton has cultivated a rich tradition of safety and innovation, developing electrical products that set the

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be

More information

for a perfect electrical installation. The range of rail-mounted terminal blocks

for a perfect electrical installation. The range of rail-mounted terminal blocks The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal

More information

SNAPConnect. Savings and Productivity Are Just a SNAP Away

SNAPConnect. Savings and Productivity Are Just a SNAP Away SNAPConnect Savings and Productivity Are Just a SNAP Away Receptacles Switches GFCI LED Power Tamper-Resistant Style Line Decorator Isolated Ground Surge Suppression Table of Contents Labor Savings Feature

More information

RSTI-EP Slice I/O. Digital Output Module

RSTI-EP Slice I/O. Digital Output Module GFK-2959B December 2015 RSTI-EP Slice I/O Digital Output Modules EP-2214, EP-2614, EP-2634, EP-2218, EP-225F Relay Output Module Solid-state Relay Output Module EP-2814 Module Status LED Channel Status

More information

Push Buttons and Operator Interface New Product Catalog XAL Control Stations

Push Buttons and Operator Interface New Product Catalog XAL Control Stations Push Buttons and Operator Interface New Product Catalog XAL Control Stations CONTENTS Description.................................................... Page General Information................................................104

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

ArrowLink Modular Wiring Devices. Devices that make installation faster, easier, more consistent and more cost effective

ArrowLink Modular Wiring Devices. Devices that make installation faster, easier, more consistent and more cost effective ArrowLink Modular Wiring Devices TM Devices that make installation faster, easier, more consistent and more cost effective ArrowLinkTM Modular Wiring Devices The Most Complete Device Installation Solution

More information

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS - For use with CONTROLTrack System Only When installing or using this track system, basic safety precautions should always be

More information

NOTICE. Operating Instructions 150W Power Pack. How to Calculate Wattage Load for 150W Power Pack EXAMPLE

NOTICE. Operating Instructions 150W Power Pack. How to Calculate Wattage Load for 150W Power Pack EXAMPLE NOTICE Warning: Risk of Fire or Electrical Shock Install the power unit 5 feet (1.5 m) or more from a pool, spa, or fountain. Where the power unit is installed (a) indoors within 10 feet (3.0m) of a pool,

More information

Installation Instructions

Installation Instructions Specifications PW-301/PW-301-347 PW-302/PW-302-347 Passive Infrared Multi-Way Wall Switch Occupancy Sensor PW-301 PW-301-347 PW-302 PW-302-347 Voltages: PW-301 & PW-302................ 120/277VAC, 50/60Hz

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

Expandable Power Systems

Expandable Power Systems Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.

More information

INTRODUCING A VISIONARY NEW COLLECTION

INTRODUCING A VISIONARY NEW COLLECTION INTRODUCING A VISIONARY NEW COLLECTION DOWN TO THE LAST DETAIL Acenti Collection Key Features: Efficient construction with consistent form factor, excellent ergonomic traits and precision feel Innovative

More information

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide *619751* P/N 619751 - Rev B IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225 A, 8 to 42

More information

PV Rapid Shutdown device

PV Rapid Shutdown device PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection MODEL NUMBER: AV88SATG Highlights 8 outlets / 8-ft. cord 2880 joule rating Auto/Manual switch offers GREEN

More information

PENDANT PUSHBUTTON STATIONS

PENDANT PUSHBUTTON STATIONS SBP2 PENDANT PUSH STATIONS SBP2 PENDANT PUSH STATIONS THE LIGHTWEIGHT PENDANT STATION FOR HEAVYWEIGHT APPLICATIONS COMPLETE PENDANT STATIONS 2, 4, 6, 8, 10, or 12 button configurations 1, 2, or 3 speed

More information

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition). PowerCore Model MPC-20 Installation Manual *Approved by CSA for non-hazardous locations (Group Safety Publication IEC 61010-1 Third Edition). Products covered in this document comply with European Council

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

Installation Instructions

Installation Instructions Specifications DW-100/DW-100-347/DW-200 v3 Dual Technology Wall Switch Occupancy Sensors DW-100 & DW-100-347 DW-200 Voltages: DW-100 & DW-200...120/277VAC, 50/60Hz DW-100-347...347VAC, 50/60Hz Limits for

More information

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays... .1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....

More information

Commodore SS Model CD General Specifications

Commodore SS Model CD General Specifications Commodore SS Model CD50200 General Specifications 0 0 0 0 0 3 0 0 0 0 0 3 Rev.4 02-02-17 Marina Electrical Equipment, Inc. 100 Warwick Court Williamsburg, VA 23185 Toll Free: 1-855-258-3939 Fax: 1-757-258-3988

More information

Installation Instructions

Installation Instructions Please read all instructions before installing RS-350 PIR Dual Relay Universal Application Wall Switch Vacancy Sensor with Manual ON/OFF Lens Lighted Switch ON/OFF button for Relay 1 ON/OFF button for

More information

Principal LED Qwik Stik Fluorescent Bulb Replacements

Principal LED Qwik Stik Fluorescent Bulb Replacements Principal LED Qwik Stik Fluorescent Bulb Replacements LED Retrofit Guide (PL-RT1-001) WARNING Installation must only be performed by a licensed electrician. To prevent death, injury or damage to property

More information

Control Box Setup - PRSalpha

Control Box Setup - PRSalpha 888-680-4466 ShopBotTools.com Control Box Setup - PRSalpha Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Parts List: Hooking Up a PRSalpha Gantry Tool Powering the

More information

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding AU1-10R AU1-10P FR1-R EU1-P Cat. No. Drawing Configuration Australian GFCI (RCD) angle plug. trip. 10 ampere 230 volt, 50 Hz. 20 watt maximum. Test

More information

Control Your World. Lighting Control System

Control Your World. Lighting Control System Lighting Control System Control Your World Today s homes have a wide variety of lights, dimmers and switches, indoors and out. Lighting control provides convenience, cost savings and an extra measure of

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 2726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Specifica. Dual USB Charger with 15/20A Duplex Tamper Resistant Receptacle Model No.: TR2USB TR2USB. Description: Features:

Specifica. Dual USB Charger with 15/20A Duplex Tamper Resistant Receptacle Model No.: TR2USB TR2USB. Description: Features: Dual USB Charger with 15/20A Duplex Tamper Resistant Receptacle Model No.: 61501-TR2USB 62001-TR2USB The 61501/62001-TR2USB USB Charger/Tamper-Resistant Receptacle offers two Smart USB charging ports and

More information

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH) Surge-Trap STZ-R series Surge Protective Device (SPD) Danger Hazard of Electrical Shock, Explosion or Arc Flash Only qualified licensed electricians should install or service SPDs Verify that all power

More information