GidasToSynop User Manual Update 09/29/2016

Size: px
Start display at page:

Download "GidasToSynop User Manual Update 09/29/2016"

Transcription

1 GidasToSynop User Manual Update 09/29/2016 Cod. SWUM_00434_en

2 Index 1. Introduction System requirements SYNOP bulletin implementation Detail of implemented data groups Management of data loaded by database automatically Groups that use last available datum Groups that use total amount data Groups that use average data Evaluation of radiation data Groups that use data variations Calculated Groups Formula for calculation of pressure at sea level and of geo-potential height Formula for calculation of dew temperature Notes about E-Log configuration Connection to Gidas database Database Updating Using the program Menu Add and change one distribution centre Add and Change one station Configuration of channels included into database Configuration of wind channels Use licences Generation of manual bulletin Save of bulletins on text file Manual bulletin for single station Manual bulletin for distribution centre Automatic bulletins generation Configuration options Program configuration file

3 1. Introduction GidasToSynop program allows to configure and set up SYNOP bulletins using the data measured by E-Log data loggers and stored into database SQL Server 2005 ( Microsoft) Gidas. The bulletins generated by the program (both from single station and combined) are saved into text file. 2. System requirements Personal computer Processor at 600 MHz operating frequency or higher. 1 GHz recommended; Display: SVGA res. 1024x768 or higher; Operating system (*): o Microsoft Windows XP SP3 (only 32 bit)/vista/7/2003/2008/8/10 Microsoft.NET Framework V.3.5 (**); LSI LASTEM Gidas Database for data recording (***). (*) Operating systems must be updated with the latest update released by Microsoft and available through Windows Update; for operating systems not listed is not guaranteed correct and complete operation of programs. (**)The Microsoft. NET Framework 3.5 setup is included in the LSI Lastem product USB issued after March 2011 and, if necessary, is automatically installed during the installation process. If you do not have the updated version of the USB you can download the installer for the Microsoft. NET Framework 3.5 directly from the Microsoft Download Center at inserting in the search field. the term ".NET". On Windows 8 and 10 you can enable. NET Framework 3.5 manually from the Control Panel. In the Control Panel you can use Add Programs and Features, then Enable or disable Windows features and then select the check box Microsoft. NET Framework This option requires an Internet connection. (*) Gidas database is installed with GidasViewer program and required SQL Server 2005 Express or higher. GidasToSynop can also be connected to Gidas database installed on SQL Server remote instance. For the system requirements of SQL Server 2005 Express, see the documentation of the GidasViewer program or the official Microsoft site 3

4 3. SYNOP bulletin implementation Implementation of SYNOP bulletins according to following details: Manual on Codes - International Codes VOLUME I.1 (Annex II to WMO Technical Regulations) 1995 edition WMO No. 306 Secretariat of the World Meteorological Organization Geneva Switzerland 1995 Part A Alphanumeric Codes According to above details the implementation includes some hypothesis and assumptions to adjust oneself to data measured by LSI LASTEM data loggers. The implementation of SYNOP details is made according to following subdivision: groups of data that are manually defined by operator and groups of data which values are automatically loaded by Gidas database where the data of LSI LASTEM data loggers have been downloaded. The program allows to prepare both manual bulletins (through operator) and automatic bulletins (without operator) Detail of implemented data groups Following table describes the implementation s detail about each section of the bulletin; the column Source shows the source (origin) of the datum: M: manual, inputted by operator; A: automatically inputted by program; C: automatically calculated by program; D: loaded from database. Section 1 IIiii i R i X hvv Nddff 1s n TTT 2s n T d T d T d 3P 0 P 0 P 0 P 0 4PPPP(4a 3 hhh) 5appp 6RRRt R 7wwW 1 W 2 8N h C L C M C H Group Description Source Notes IIiii International Index Number M i R i X hvv i R =Precipitation Inclusion-Exclusion i X =Type operation h=cloud Height VV=VisibilityGroup A A M M Parameter i R is automatically assigned according to table (Code Table 1819). Parameter i X has value 6 if bulletin is generated in automatic mode. 4

5 Group Description Source Notes Nddff N=Total Cloud Cover M Unit of measurement of Wind intensity in m/s ddff=wind Group D 1s n TTT Air Temperature Group D 2s n T d T d T d Dew Point Temperature Group or Relative Humidity C D If bulletin includes Dew Point Temperature the calculation is according to EN ISO P 0 P 0 P 0 P 0 Station Pressure Group D 4PPPP Sea Level Pressure Group C If value of Sea Level Pressure is calculated using the formula written in WMO Instruments and Observing Methods Report No.19 par. 6.5 Sea level Pressure. If group has form 4a 3 hhh the geo-potential height of selected isobaric surface is calculated using the inverse formula. 5appp 3-Hour Pressure Tendency D Parameter a has value 2 in case of positive variation and value 7 in case of negative variation 6RRRt R Amount of Precipitation Group D Time t R is evaluated during configuration of the station: the program allows to define two values that can be used for different issue times 7wwW 1 W 2 Present and Past Weather Group M 8N h C L C M C H Cloud Type Group M Section 2 Section 2 isn t supported. Section 3 0C S D L D M D H 1s n T X T X T X 2s n T n T n T n 3Ejjj 4E sss 5j 1 j 2 j 3 j 4 6RRRt R 7R 24 R 24 R 24 R 24 8N s Ch s h s 9S p S p s p s p Group Description Source Notes 0C S D L D M D H State of the Sky in the Tropics M Group 1s n T X T X T X Maximum Temperature Group D This group is evaluated during past 24 hours 2s n T n T n T n Minimum Temperature Group D This group is evaluated during past 24 hours 3Ejjj State of the Ground without Snow M 4E sss State of the Ground with Snow M 5j 1 j 2 j 3 j 4 Regional supplementary Group - View the following table 6RRRt R Amount of Precipitation Group D Time t R is evaluated during configuration of the station: the program allows to define two values that can be used for different issue times 7R 24 R 24 R 24 R Hour Precipitation Group D 8N s Ch s h s Individual Cloud Layer Group M 9S p S p s p s p Special Phenomena Group M Regional Supplementary Group 5EEEi E 54g 0 s n d T 55SSS(j 5 F 24 F 24 F 24 F 24 ) 56D L D M D H 58P 24 P 24 P 24 or 59P 24 P 24 P 24 Group Description Source Notes 5EEEi E Amount of Evaporation D Parameter i E has value 4 54g 0s nd T Temperature Change Group M 55SSS Duration of Sunshine D This group is always evaluated during past 24 hours j 5F 24F 24F 24F 24 Radiation During Preceding 24 hours D If there is group 55SSS it s possible input groups 2FFFF and 3FFFF too (global and diffused solar 5

6 56D L D M D H Cloud Direction Movement Group M 58P 24P 24P Hour Pressure Change Group D 59P 24P 24P 24 radiation during preceding 24 hours) 3.2. Management of data loaded by database automatically The data loaded by database automatically make reference to following quantities: Wind intensity and direction, and standard deviation (optional) Temperature Pressure Relative humidity Rainfall Evaporation Insolation Radiation All groups marked with D in previous tables make reference to these quantities. They are groups used for carrying out of manual bulletins (without operator intervention). For this reason during configuration of one station the user must specify: the references needed to identify the datum inside Gidas database, and also the times in which the groups, connected to these quantities, must be included in the bulletin (ref ). As the time of bulletin generation isn t usually the same time of real output, during configuration it s possible specify one time parameter (minutes) that specify the slot in which consider the data of automatic station (Tr). For example, if we evaluate the slot of 20 minutes, when it generates the bulletin referred to 12 o clock the program considers the data of station included into the slot WARNING: The program considers that data included into database are quantified in hour UTC Groups that use last available datum Following groups use the latest datum included into slot [bulletin time] ; [ bulletin time] - [datum search time (Tr)]: Section 1 - Nddff Section 1-1snTTT Section 1-2snTdTdTd Section 1-3P0P0P0P0 6

7 Groups that use total amount data Following groups use the addition of data, included into slot required by bulletin, like specified in the above mentioned tables: Section 1-6RRRtR Section 3-7R24R24R24R24 Section 3-5EEEiE Section 3-55SSS Groups that use average data Following groups use the average of data included into slot required by bulletin like specified in the above mentioned tables: Section 3 - j5f24f24f24f Evaluation of radiation data The radiation data are reported inside bulletins using J/cm 2 unit and are referred to last 24 hours. As the instruments measures the data using W/m 2 unit, the average datum is correct through conversion coefficient and then multiplied by seconds Groups that use data variations Following groups evaluate the difference among data included inside one slot: the data are considered like valid if included inside search time of datum Tr. Section 3 (3 hours) - 5appp Section 3 (24 hours) - 58P24P24P24 Section 3 (24 hours) - 59P24P24P Calculated Groups Groups 2snTdTdTd (Dew Point Temperature), 4PPPP (Sea Level Pressure) and 4a3hhh (Geopotential Height) are calculated by program directly Formula for calculation of pressure at sea level and of geo-potential height The calculation of pressure at sea level is made according to section of following WMO publication: ( INSTRUMENTS AND OBSERVING METHODS REPORT No. 19 SOME GENERAL CONSIDERATIONS AND SPECIFIC EXAMPLES IN THE DESIGN OF ALGORITHMS 7

8 FOR SYNOPTIC AUTOMATIC WEATHER STATIONS The formula needs the data about temperature, pressure and relative humidity and the station s height too. If required the calculation of geo-potential height is obtained using the inverse formula Formula for calculation of dew temperature The calculation of dew temperature is made using formula included into rule EN ISO 7726 Ergonomics of the thermal environment Instruments for measuring physical quantities. 4. Notes about E-Log configuration In order to use SYNOP, take into consideration following instructions during configuration of E- Log data loggers: elaboration rate: 10 minutes; synchronize the clocks of instruments on UTC hour; keep the default units of measurement; as radiometer doesn t measure the diffused radiation, set up one channel so that the instrument can supply this datum directly. The default units of measurement are the following: wind direction and standard deviation: degrees; wind intensity: m/s; temperature: C; evaporation: mm; radiation: W/m 2 ; pressure: hpa; rainfall: mm; insolation: minutes. The calculation of Sea Level Pressure (or of Geopotential Height) needs the channels of temperature, pressure and relative humidity; the calculation of Dew Point Temperature needs the data of relative humidity and temperature. The program allows the input of one multiplicative factor in order to modify the units of measurement used by measured data as regards the units of measurement used in different bulletin s groups. In the following list you can find the pre-set factors that are different from one and that correspond to the above mentioned units of measurement; in brackets there is the unit of measurement used in the bulletin: air direction (tens of degree): 0,1; temperature (tenths of C): 10; pressure (tenths of hpa): 10; evaporation (tenths of mm): 10; radiation (J/cm 2 ): 0,0001. WARNING: Do not modify the units of measurement of insolation and wind intensity. 8

9 5. Connection to Gidas database When you start program first time, you need to specify Gidas database from which load data to generate SYNOP bulletin. In order to connect to Gidas database (or modify current instance) select menu File Change Data Source. This menu opens the window for selection of data source: Specify the instance of SQL Server to connect to and check connection through key (for further information about identification of SQL Server instances make reference to Errore. L'origine riferimento non è stata trovata.). WARNING If you use Windows authentication, actual user needs the privileges required for connection to instance of SQL Server and use Gidas database. The list of SQL Server instances shows the instances of SQL Server which have been identified in local computer; depending on the setup of net administration the instances of SQL Server inside the network can be displayed. It s possible select one value from the list or set up a new one. The name of an SQLServer instance has the following format: [servername]\[instancename] [servername] is the network name of the computer where SQL Server has been installed (in case of local instances it s possible use whether name of the computer or word (local) or only the point). If Gidas database was installed in the default LSI instance set the instancename parameter to LSIDB:.\LSIDB or [computername]\lsidb 9

10 5.1. Database Updating GidasToSynop program uses last realease of Gidas database and needs to add some tables and Stored Procedures. The program makes this operation automatically when it connects to one data source which doesn t have them. In order to update Gidas database you have to connect to the instance of SQL Server using administrator s privileges; if connection doesn t have these privileges, it will ask to arrange login using administrator s privileges (ask the help of database administrator to use a network database): Alternatively it s possible arrange the manual update of database using script SynopCreate.sql situated in: C:\Documents and Settings\All Users\Dati applicazioni\lsi- Lastem\GidasToSynop\Library 10

11 6. Using the program GidasToSynop program allows the configuration of weather stations grouping them in distribution centers, in order to send SYNOP bulletins. The bulletins can be generated in automatic mode (using only data on Gidas database) or in manual mode (adding other data supplied by operator). The left side of program s main window shows the distribution centres configured with the included stations that are identified by them international code consisting of 5 numbers. The right side shows the main characteristics of selected item. The different functions of the program can be selected from main menu, from keys bar and from contextual menu on Browser nodes. The status bar shows the current data source, the possible need to setup the data (if modified), and current UTC time. 11

12 6.1. Menu The program has following menus: File Change Data Source: it displays the window to modify the instance of Gidas database used by program. The program can use local database and remote database too; Save: it saves the configuration s changes inside; Exit: it closes the program. Edit Add Center: it adds one distribution centre (ref. 6.2); Add Station: it adds one new station to one distribution centre (ref. 6.3); Remove Station: it removes the selected station; Edit Station: it modifies the selected station (ref. 6.3). Tools Create Bulletin -> Create Station Bulletin: it sets up the bulletin for selected station; Create Bulletin -> Create Center Bulletin: it sets up the bulletin for selected distribution centre; Run Automatic Bulletin: it starts the mode for automatic setup of bulletins; Stop Automatic Bulletin: it stops the mode for automatic setup of bulletins; Test Calculation and Synop Coding: it opens the window for test of: calculations of calculated quantities and coding of Synop supported data belonging to different bulletin s groups; Options: it imports the configuration s general options.? Contents: it shows program s user manual; Check for Updates: it starts the request of program s updates; About: it shows the window about program s information. You can find some of these menus like keys bar, under menu of main window Add and change one distribution centre Distribution centre is the container of single configured stations. To add one new distribution centre select menu Edit Add Center or select node Synop of Browser and contextual menu Add New Center. To modify an existing distribution centre select the distribution centre that you want modify and contextual menu Edit. These functions start the guided procedure for input of one new distribution centre: 12

13 In the above figure you can see the data required for configuration of distribution centre; they make reference to data included into bulletin s header: T1T2A1A2ii CCCC YYGGgg (BBB) MiMIMjMj Please consider that: If T1= S, the value of T2 can be set up by program automatically ticking the respective box; BBB indicator isn t supported. After the input of general parameters, the guided procedure will ask you the input of several stations that belong to this group (ref. 6.3). If guided procedure has been started in change mode, it ISN T possible change the CCCC centre s code Add and Change one station 13

14 To add new station to one distribution centre select distribution centre in Browser and menu Edit Add Station or contextual menu Add New Station. To modify an existing station select the station you want modify and contextual menu Edit. Following functions start the guided procedure for input of new station: First screen needs the input of general information referred to one station. Particularly: Time interval to get data: they are the minutes to deduct from bulletin s issue time in order to consider the valid data reached to the station. Dew point temperature group: it shows if group 2 of section 1 include the dew temperature or relative humidity. Bear in mind that for calculation of dew temperature it s needed the relative humidity channel. Sea level pressure mode: it shows the representation modes of group 4 of section 1; it s possible to calculate the pressure at sea level, calculate the geo-potential height of one selected reference surface, or leave out the group. The next screen allows the configuration of timing and the access to database for measures of section 1. Bear in mind that (when you have set a bulletin s issue time) the quantities acquired from database can be automatically calculated ONLY if they have been configured to be inputted into bulletin at specified time. 14

15 Particularly: Icon near each item shows if the item has been configured or not; if it hasn t been configured (Unavailable) it won t never be inputted into any bulletin; The configuration of one item needs the specification of group attendance time inside bulletins (Schedule) and the configuration of parameters for access to Gidas database (Gidas Source); To modify the configuration of one item: double-click on the item included in the list (ref ). The following screens are the same like the above and are referred to groups of section 3 and groups of section radiation, if group 55SSS (Sunshine) has been configured. In the last screen you have to specify the parameter t R that states the rainfall s valuation period, if group 6 in section 1 and/or 3 (rainfall) has been required. 15

16 The program allows to specify one main slot (time interval) and one second slot to use at specified times; in this way it s possible differentiate the extraction recurrence of data according to bulletin s issue. WARNING: Consider that all groups correlated to stated quantity (for example the different groups that include the Pressure) always use same data access channel. For example it isn t possible to specify one Gidas channel for group 3 and one different channel for group 5 as both channels are referred to pressure data. If guided procedure has been started like modification mode it ISN T possible to change the station s code Configuration of channels included into database Double click on one item included in previous screen s list to start the channels configuration window. 16

17 In this window you can: Select bulletins times for input of selected group; it s also possible select single hours; Configure the passwords for access to Gidas database pressing key ; they identify the considered quantity (in the example it s the temperature channel); Set possible conversion factor between the unit of measurement of datum in database and the unit of measurement of datum inputted into the bulletin; in the example the temperature is measured C and the multiplication factor is 10, because the groups of bulletin use tenths of degree; Press key Remove to cancel the channel programming. WARNING: Also for manual bulletins the groups that load data from database are inputted ONLY is they have been timed for bulletin s time. The window for set Gidas field to represent selected measure will start pressing key : 17

18 This window shows all instruments included into database: to configure one measure (in this case the temperature) select the corresponding instrument, its configuration, the channel and the corresponding elaboration. We recommend to use elaboration Average item. Press <Ok> to confirm the selection. WARNING: If channel hasn t been configured for access to database it won t be inputted into any bulletin Configuration of wind channels The window for configuration of wind channels (intensity, direction and standard deviation) doesn t allow the setup of scheduling because the group is always present. It s also possible specify the channel of standard deviation and one threshold value; above this value the direction datum has value 99, that is variable and not-determinable direction Use licences The program allows to display the data of instruments included into Gidas database for which one licence file valid for program GidasToSynop is available; the user can ask the LSI LASTEM for licence file. In case the licence file isn t available, the instrument is displayed in Navigator with icon the access to its data isn t allowed. and 18

19 6.4. Generation of manual bulletin The program allows the generation of manual bulletins (through operator intervention) for single station and for distribution centre too Save of bulletins on text file The manual and automatic bulletins are saved on text file with following name: [path]\yyyy_mm_dd.hh_[code].txt where: [path]: it shows the save path of bulletins and it s set up in general options window (ref. 6.6); yyyy_mm_dd.hh: it shows the date the bulletin is referred to; [Code]: it s the code of station for single station bulletin, the code of centre for distribution centre bulletin Manual bulletin for single station In order to open the window for generation of single station bulletin, select the station from navigator and use contextual menu Create Bulletin: 19

20 Particularly: select date and bulletin creation UTC hour (it s considered the data stored into database are always referred to UTC hour); at opening of window these values are initialized on current date and higher intermediate synoptic hour; enable the groups that have to be manually inserted into bulletin and input their values: the input fields accept numerical characters and character / that s the missing datum; if one group is enabled but any value isn t inputted, the group WON T be inputted into bulletin; select tick box If checked insert bulletin header to input the header of distribution centre (the station belongs to) into bulletin; select tick box If checked insert debug information to queue in bulletin the original data got from database for groups connected to automatic data; this function can be useful during check of program operation; 20

21 Select card Station Configuration to check the configuration setups for automatic data. Press key Create Bulletin to show bulletin preview window. Select tick box Enable bulletin editing to enable the bulletin s editing WARNING: If bulletin has been modified, the program doesn t carry out ANY compatibility check. Press key Save to save bulletin on file. It ll save all displayed contents, including possible information about bulletin source data Manual bulletin for distribution centre In order to open the window for generation of bulletin for one distribution centre, select the distribution centre from browser and use contextual menu Create Bulletin: 21

22 Particularly: Select date and bulletin creation UTC hour (it s considered that data stored into database are always referred to UTC hour); at the opening of the window these values are initialized on current date and higher intermediate synoptic hour; Select tick box If checked insert the bulletin header to input, under emission centre s string (always inputted), the string MMMM YYGGiw; The list shows the stations included in the group. Press key Create Bulletin to start bulletin creation. During bulletin creation it s successively displayed the manual creation s window of each single station included in the group. The bulletin s creation follows the instruction in (ref ), but the preview window isn t displayed: If you press key Create Bulletin in window for creation of single source s bulletin, the program creates the bulletin of that station and queues it in bulletin of distribution centre; If you press key Close in window for creation of single source s bulletin, the program DOESN T create the bulletin of that station. When the cycle on all sources included in the distribution centre has been finished, the program shows the above mentioned bulletin s preview window (ref ) Automatic bulletins generation Selecting menu Tools Run Automatic Bulletin the mode for automatic generation of bulletins starts. 22

23 This window displays the execution information in Log paragraph, and last created bulletin in Last Created Bulletins card. The execution information is stored on text file in the folder: C:\ProgramData\LSI-Lastem\GidasToSynop\Log Every day the program creates one file including execution information (if mode for automatic creation of bulletins has been started). Key Open Logs Folder places program Windows Explorer on folder in which the files with execution information are stored. Key Clear Logs removes the execution information from window (but not from files). Press key Stop to stop the automatic execution ; press key Start to re-start it. WARNING: The configuration and the general options cannot be modified during operation of mode for automatic generation of bulletins. If necessary, stop the mode pressing Stop, make the modifications, save them into database and re-start the mode pressing Start Configuration options Selecting menu Tools Options the window for configuration of program s general options starts: 23

24 You have to input the path (local or network) for saving of generate bulletins and configure the options for mode for automatic creation of bulletins. Particularly: Set up the minutes of slot (time interval) referred to bulletin s creation time; if you set up 5 minutes, the bulletin of 12 o clock will be created at 5 past 12. This slot can be useful to allow the instruments the sending of updated data; Set up the hours for generation of bulletins: every station will input the scheduled groups referred to stated time Program configuration file The name of program configuration file is GidasToSynop.exe.config and it s located in the folder of program installation. The format of file is xml and it includes come default setups: where: <LSI_Lastem.Lib2.Gidas.Synop.UI.Properties.Settings> <setting name="userdefinedculture" serializeas="string"> <value /> </setting> <setting name="maxlogmessages" serializeas="string"> <value>500</value> </setting> <setting name="debugnumberformat" serializeas="string"> <value>f2</value> </setting> </LSI_Lastem.Lib2.Gidas.Synop.UI.Properties.Settings> 24

25 UserDefinedCulture: language used by program. If computer s language is Italian the program starts using Italian like default language (not stated value), otherwise it starts using English. To force the use of English in Italian computer input value <value>enus</value>; to use Italian in other language computer input value <value>it-it</value>. MaxLogMessages: maximum number of log messages shown in the automatic bulletin engine window. DebugNumberFormat: numeric format of variable values show in the bulletin in the debug mode; insert Fn where n is the number of decimal value to show. 25

GidasToSynop User Manual Update 11/11/2008

GidasToSynop User Manual Update 11/11/2008 GidasToSynop User Manual Update 11/11/2008 Cod. SWUM_00434_en Index 1. Introduction... 3 2. System requirements... 3 3. SYNOP bulletin implementation... 4 3.1. Detail of implemented data groups... 4 3.2.

More information

GidasPenman (FAO Penman Monteith evapotranspiration index) User s Manual

GidasPenman (FAO Penman Monteith evapotranspiration index) User s Manual GidasPenman (FAO Penman Monteith evapotranspiration index) User s Manual Updated on 31/03/2011 Cod. SWUM_00675_en Sommario 1. Introduction... 3 1.1. Applicability limits... 4 2. System requirements...

More information

3DOM Free Data logger Oriented Manager User Manual Revision 2014/11/03

3DOM Free Data logger Oriented Manager User Manual Revision 2014/11/03 3DOM Free Data logger Oriented Manager User Manual Revision 2014/11/03 Cod. SWUM_00339_en LSI LASTEM 3DOM User s manual Index 1. Introduction... 4 2. System Requirements... 4 3. Installation... 5 3.1.

More information

3DOM Free Data logger Oriented Manager User Manual Revision 2018/02/08

3DOM Free Data logger Oriented Manager User Manual Revision 2018/02/08 3DOM Free Data logger Oriented Manager User Manual Revision 2018/02/08 Cod. SWUM_00339_en LSI LASTEM 3DOM User s manual Index 1. Introduction... 4 2. System Requirements... 4 3. Installation... 5 3.1.

More information

CommNet. User s Manual Update 02/02/2009. Cod. SWUM_00049_en

CommNet. User s Manual Update 02/02/2009. Cod. SWUM_00049_en CommNet User s Manual Update 02/02/2009 Cod. SWUM_00049_en Index 1. Introduction...3 2. System Requirements...3 3. Installation...4 3.1. Organization of the installed files...4 4. Foreword...5 5. CommNet

More information

Cod. MW6165. R-Log. Quick Start

Cod. MW6165. R-Log. Quick Start od. MW6165 R-Log Quick Start Update 12/19/2013 Summary 1. Introduction... 3 2. To start... 3 3. First installation... 3 3.1. Installing the software on your P... 6 3.1.1. Installation procedure... 6 3.1.2.

More information

GidasTEA (Gidas Thermal Environment Application) User s manual

GidasTEA (Gidas Thermal Environment Application) User s manual GidasTEA (Gidas Thermal Environment Application) User s manual Update 11/05/2014 Cod. SWUM_00662_en Summary 1. Introduction... 4 2. System requirements... 4 3. New version update... 5 4. Reference standards

More information

41126 Cognento (MODENA) Italy Via Bottego 33/A Tel: +39-(0) Internet: Fax: +39-(0)

41126 Cognento (MODENA) Italy Via Bottego 33/A Tel: +39-(0) Internet:     Fax: +39-(0) QUICK ANALYZER User Guide Version 5.3 Index 1.0 Generality... 2 LICENSE AGREEMENT... 3 2.0 Channels Configuration... 4 2.1 IdroScan Data Log Management... 6 3.0 Test Results... 9 4.0 Excel Export... 10

More information

Format specification for the SMET Weather Station Meteorological Data Format version 1.1

Format specification for the SMET Weather Station Meteorological Data Format version 1.1 Format specification for the SMET Weather Station Meteorological Data Format version 1.1 Mathias Bavay November 28, 2017 Abstract The goal of this data format is to ease the exchange of meteorological

More information

Script.byu.edu SharePoint Instructions

Script.byu.edu SharePoint Instructions Script.byu.edu SharePoint Instructions Site Actions Menu Go to script.byu.edu, click on Authenticate at the bottom of page, you will be prompted to enter a username and password, use your netid and password

More information

Summary I Minimum system requirements...2

Summary I Minimum system requirements...2 Logiciel 1 Summary I Minimum system requirements...2 I 1 Minimum configuration required...2 I 2 uninstallation...2 I 3 Launching application...2 II installation...2 III presentation...3 III 1 Home page...3

More information

User Manual. Recorder of environmental conditions THBR. Version: 2.0.2

User Manual. Recorder of environmental conditions THBR. Version: 2.0.2 User Manual Recorder of environmental conditions THBR Version: 2.0.2 2 TABLE OF CONTENTS 1. INTENDED USE... 4 2. INSTALLATION... 5 2.1. System requirements... 5 2.2. Installation process... 5 2.3. Program

More information

PC APPLICATION SOFTWARE WEATHER OS (MODEL: WMR100 / WMR200 / WMRS200 / I300 / I600 / EMS100 / RMS300 / RMS600) USER GUIDE IMPORTANT: LAUNCH SOFTWARE

PC APPLICATION SOFTWARE WEATHER OS (MODEL: WMR100 / WMR200 / WMRS200 / I300 / I600 / EMS100 / RMS300 / RMS600) USER GUIDE IMPORTANT: LAUNCH SOFTWARE PC APPLICATION SOFTWARE WEATHER OS (MODEL: WMR100 / WMR200 / WMRS200 / I300 / I600 / EMS100 / RMS300 / RMS600) USER GUIDE CONTENTS Launch Software...1 Installation...1 Select language...1 Select cities

More information

CARPATCLIM Date Version Page Report Final version (1)14. Deliverable D1.15

CARPATCLIM Date Version Page Report Final version (1)14. Deliverable D1.15 CARPATCLIM Date Version Page Report 28-11-2011 Final version (1)14 Deliverable D1.15 Implemented drafts version of metadata per country of meteorological stations selected for this project, including the

More information

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

UNIVERSAL SOFTWARE. Universal Software. Data Sheet Universal Software Data Sheet System Requirements: The minimum requirements for using the Software are: 1). Windows XP/Vista/7 2). A minimum of 512 MB RAM 3). 1 GB of hard disk space 4). Microsoft Office

More information

QRM Installation Guide Windows

QRM Installation Guide Windows 1 The Compatible with LabVIEW logo is a trademark of National Instruments Corporation and is used under a license from National Instruments Corporation. 1 2 Contents 1 Document Change History... 3 2 Documents

More information

RF-Monitor B User's Guide

RF-Monitor B User's Guide www.loggerteknik.se Newsteo RF-Monitor B User's Guide for Monitoring Logger Version 1.2 TEL 031-760 60 16 Phone int. +46 31 760 60 16 Purpose User guide for Newsteo RF-Monitor B v3.0.7 Technical support

More information

Digital thermo-hygro-barometer with external probe Manual for use

Digital thermo-hygro-barometer with external probe Manual for use COMMETER D4141 Digital thermo-hygro-barometer with external probe Manual for use Instruction manual for use of thermo-hygro-barometer COMMETER D4141 Instrument is designed for measurement and data logging

More information

SOFTWARE PECO-GRAPH. User Manual COUNTING DATA GRAPHICAL REPRESENTATION AND MANAGEMENT SOFTWARE. User Manual version - 4.

SOFTWARE PECO-GRAPH. User Manual COUNTING DATA GRAPHICAL REPRESENTATION AND MANAGEMENT SOFTWARE. User Manual version - 4. SOFTWARE PECO-GRAPH User Manual COUNTING DATA GRAPHICAL REPRESENTATION AND MANAGEMENT SOFTWARE User Manual version - 4.10 ENGLISH Copyright 2018 AX Solutions, S.L. All rights reserved. Visual Tools products

More information

Software Description Application Software OTT Hydras 3 net

Software Description Application Software OTT Hydras 3 net English Software Description Application Software OTT Hydras 3 net We reserve the right to make technical changes and improvements without notice! Table of contents 1 Overview of OTT Hydras 3 net 5 2 Data

More information

VDG Supervisor. User s manual. A 07/2009 Original publication J.D. GUICHARD C. BERTRAND Ind Date Designation Author Approved

VDG Supervisor. User s manual. A 07/2009 Original publication J.D. GUICHARD C. BERTRAND Ind Date Designation Author Approved ALGADE INSTRUMENTATION DOCUMENT NU-XFAB545-208 ind A VDG Supervisor User s manual A 07/2009 Original publication J.D. GUICHARD C. BERTRAND Ind Date Designation Author Approved 07/2009 ALGADE. All rights

More information

The framework of next generation automatic weather station in China

The framework of next generation automatic weather station in China The framework of next generation automatic weather station in China Xiaozhong CAO 1, Ming ZHANG 1, Bo WEN 2, Bailin WANG 3, Yong LEI 1 (1. Meteorological observation center of CMA, 2. China meteorological

More information

S u n V i s i o n U s e r a n d I n s t a l l a t i o n M a n u a l 0MNU118NPC-GB

S u n V i s i o n U s e r a n d I n s t a l l a t i o n M a n u a l 0MNU118NPC-GB S u n V i s i o n U s e r a n d I n s t a l l a t i o n M a n u a l 0MNU118NPC-GB Contents 1 What is SunVision?... 1 1.1 Support and declaration of liability... 1 1.2 Copyright... 1 2 SunVision installation

More information

Network Management Card. User Manual

Network Management Card. User Manual User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1

More information

HD PLAYER SOFTWARE USER GUIDE Chapter 1- Install and Uninstall... Error! Bookmark not defined.

HD PLAYER SOFTWARE USER GUIDE Chapter 1- Install and Uninstall... Error! Bookmark not defined. HD PLAYER SOFTWARE USER GUIDE Chapter 1- Install and Uninstall... Error! Bookmark not defined. 1. Software instal...... 1 2. Software uninstall...... 4 Chapter 2- Network setting...... 4 Chapter 3- Edit

More information

IMS4 AMS 111 II M. Automatic Mobile Weather Station for military usage AMS 111 II M

IMS4 AMS 111 II M. Automatic Mobile Weather Station for military usage AMS 111 II M IMS4 Automatic Mobile Weather Station for military usage FEATURES: Military class equipment Military design optional Aviation weather observation Climatological observation Synoptic observation Radiation

More information

1. Software instal Software uninstall... 4

1. Software instal Software uninstall... 4 Catalog Chapter 1- Install and Uninstall... 1. Software instal... 1 2. Software uninstall... 4 Chapter 2- Network setting... 4 Chapter 3- Edit the Program... 5 1. Software Interface... 5 2. Program Stucture...

More information

PROFESSIONAL WIRELESS WEATHER STATION. Operation Manual - 1 -

PROFESSIONAL WIRELESS WEATHER STATION. Operation Manual - 1 - PROFESSIONAL WIRELESS WEATHER STATION Operation Manual - 1 - OVERVIEW Outdoor sensor: 1. Wind Vane 2. Wind Speed Sensor 3. Solar panel 4. Battery compartment 5. LED Indicator: light on for 4 seconds during

More information

TagTemp-NFC 3 TECHNICAL DATA 1 INTRODUCTION 2 MECHANICAL INSTALATION. TEMPERATURE LOGGER INSTRUCTIONS MANUAL V 1.0x D

TagTemp-NFC 3 TECHNICAL DATA 1 INTRODUCTION 2 MECHANICAL INSTALATION. TEMPERATURE LOGGER INSTRUCTIONS MANUAL V 1.0x D TagTemp-NFC TEMPERATURE LOGGER INSTRUCTIONS MANUAL V 1.0x D 1 INTRODUCTION The TagTemp-NFC is an electronic temperature logger. The sensor measures this physical quantity and the values are stored in memory.

More information

HDPlayer Operating Manual

HDPlayer Operating Manual Catalog Chapter 1- Install and Uninstall...2 1. Software Install...2 2. Software Uninstall...4 Chapter 2- Network setting...4 The controller can connect to the computer directly. It can also connect to

More information

INDIAN INSTITUTE OF TECHNOLOGY DEPARTMENT OF CIVIL ENGINEERING

INDIAN INSTITUTE OF TECHNOLOGY DEPARTMENT OF CIVIL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY DEPARTMENT OF CIVIL ENGINEERING Sub: Quotation for supply of Weather Station Enquiry letter for Weather Station Reference: IITK/SERB/2017-3-1 Dated 31.03.2017 Sir / Madam,

More information

SecureClient Central: Installation Guide

SecureClient Central: Installation Guide e-volve SecureClient Central: Installation Guide September 2011 Table of contents 1. About this guide...3 2. System requirements...4 3. Installation...5 Appendix 1 Notes for the IT Department...10 1. Having

More information

ANNEX AGRI/20 AGRO-METEOROLOGICAL EQUIPMENT & SPARE PARTS ANNEX AGRI / 20 - A. Equipment & spare parts

ANNEX AGRI/20 AGRO-METEOROLOGICAL EQUIPMENT & SPARE PARTS ANNEX AGRI / 20 - A. Equipment & spare parts ANNEX AGRI/20 AGRO-METEOROLOGICAL EQUIPMENT & SPARE PARTS ANNEX AGRI / 20 - A. Equipment & spare parts Total Qty. Proposed Allocation DHK ERB SUL Intend. use Compliment. Application Delivery 05-20-00001

More information

National and Regional FDR Data Management in Southeast Asia

National and Regional FDR Data Management in Southeast Asia National and Regional FDR Data Management in Southeast Asia GUSWANTO Research and Development Center Indonesian Meteorological and Geophysical Agency () International Workshop On Advances In Operational

More information

How to Install and Setup VoIPOffice Communicator for Mac

How to Install and Setup VoIPOffice Communicator for Mac Page 1 of 10 How to Install and Setup VoIPOffice Communicator for Mac (Software Release 3.8.10) This guide will show you how to install and setup VoIPOffice Communicator for Mac. Click the button below

More information

PC-Cluster Operation Manual

PC-Cluster Operation Manual PC-Cluster Operation Manual 1. Start PC-Cluster 1.1. Power ON (1) Confirm power cables Connected OUTLET AVR UPS PC-Cluster (2) Switch ON AVR Switch ON (3) Switch ON UPS Switch ON PC-Cluster Operation Manual

More information

A EX I. Automatic Weather Station:

A EX I. Automatic Weather Station: A EX I Automatic Weather Station: AWS System Overview: Manufacturer should provide the following items along with all AWS spare parts for at least five years and should notify if and whenever any one of

More information

Deployment Guide Installing WhatsUp Gold Distributed Edition to Central and Remote Sites

Deployment Guide Installing WhatsUp Gold Distributed Edition to Central and Remote Sites Deployment Guide Installing WhatsUp Gold Distributed Edition to Central and Remote Sites This guide provides information about installing and configuring WhatsUp Gold Central and Remote Sites. Contents

More information

Datalogger Gealog SG. Datalogger Gealog SG. Gealog SG with graphic display

Datalogger Gealog SG. Datalogger Gealog SG. Gealog SG with graphic display Gealog SG with graphic display Page 1 of 13 Innovation leader in environmental monitoring stations The Gealog SG datalogger was especially designed for application in hydrometeorological measuring stations.

More information

Network Management Card. User Manual

Network Management Card. User Manual User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1

More information

Movicon NExT Pro.Lean Ver.3.2. Print Doc Movicon

Movicon NExT Pro.Lean Ver.3.2. Print Doc Movicon Movicon NExT Pro.Lean Ver.3.2 Print Doc Movicon Table of Contents 1. PRO.LEAN... 1 1.1. WHAT IS PRO.LEAN?... 1 1.2. THE ADVANTAGES OF MEASURING PRODUCTION PERFORMANCES... 3 1.3. GETTING STARTED: CONFIGURING

More information

ALMS Desktop Application User Manual

ALMS Desktop Application User Manual ALMS Desktop Application User Manual ALMS Desktop Application 1 Contents 1. INTRODUCTION... 2 1.1) Overview... 2 2. PRODUCT FEATURES... 2 3. BASIC REQUIREMENTS... 2 3.1) Software and hardware requirements...

More information

A Primer on Writing BUFR templates

A Primer on Writing BUFR templates A Primer on Writing BUFR templates Yves Pelletier National Prediction Operations Division, Meteorological Service of Canada Version 1.4, July 18, 2008 Table of Contents A Primer on Writing BUFR templates...1

More information

Data Automator Installation and Getting Started Guide

Data Automator Installation and Getting Started Guide Data Automator Installation and Getting Started Guide Contents Introduction... 3 Minimum Requirements... 4 Supported Operating Systems... 4 Other requirements... 4 Installation... 5 Configuration Folder

More information

Immotec Systems, Inc. SQL Server 2008 Installation Document

Immotec Systems, Inc. SQL Server 2008 Installation Document SQL Server Installation Guide 1. From the Visor 360 installation CD\USB Key, open the Access folder and install the Access Database Engine. 2. Open Visor 360 V2.0 folder and double click on Setup. Visor

More information

INSTRUCTIONS MANUAL V2.9x B

INSTRUCTIONS MANUAL V2.9x B www.superview.com.br INSTRUCTIONS MANUAL V2.9x B INDEX INDEX... 1 INTRODUCTION... 3 INSTALLATION... 4 SYSTEM REQUIREMENTS... 4 INSTALLATION PROCEDURES... 4 SOFTWARE LANGUAGE SELECTION... 4 FIRST STEPS...

More information

2009 Davis Instruments Corp. All rights reserved. Information in this document is subject to change without notice.

2009 Davis Instruments Corp. All rights reserved. Information in this document is subject to change without notice. FCC Part 15 Class B Registration Warning This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed

More information

Software installation

Software installation Table of contents 1 Introduction...4 2 Software installation...4 2.1 Protection...4 2.2 Minimum recommended configuration...4 2.3 Installation...4 3 Uninstall the application...4 4 Software presentation...5

More information

Power Vision 1.5 (Cod )

Power Vision 1.5 (Cod ) ELECTRICAL NETWORK ANALYSIS SOFTWARE Power Vision 1.5 (Cod. 775 353) USER S MANUAL (Cod. M 981 358 / 02 D) 2002 - CIRCUTOR, S.A. INDEX 1.- POWER VISION SOFTWARE INSTALLATION...4 2.- INTRODUCTION TO POWER

More information

Therefore, before you can use the Microlog Inspector application for the first time, you must perform the following steps:

Therefore, before you can use the Microlog Inspector application for the first time, you must perform the following steps: SKF Microlog Inspector Setup Guide Microlog Inspector setup overview The new Microlog Inspector application uses a different, much easier communication method than previous MARLIN versions. With the new

More information

Manual Lindab Analysis. PC-Software Lindab PC 410 and LT 600 for data management and online measurement with logger function. Art. n.

Manual Lindab Analysis. PC-Software Lindab PC 410 and LT 600 for data management and online measurement with logger function. Art. n. Art. n. 23110 2016-05-17 Manual Lindab Analysis PC-Software Lindab PC 410 and LT 600 for data management and online measurement with logger function Application Contents 1 Application... 3 2 System requirements...

More information

User manual BS1000 LAN base station

User manual BS1000 LAN base station 1/18 Contents 1.Introduction 2.Package of the LAN Base Station 3.Software installation 4.Installation of the Receiver 5.Sensor operation 6.Software operation Introduction The BS1000 is a receiver station

More information

Device for the Remote Measurement of Meteorological Data Based on Arduino Platform

Device for the Remote Measurement of Meteorological Data Based on Arduino Platform SERBIAN JOURNAL OF ELECTRICAL ENGINEERING Vol. 13, No. 1, February 2016, 133-144 UDC: 551.501:621.31]:519.6 DOI: 10.2298/SJEE1601133T Device for the Remote Measurement of Meteorological Data Based on Arduino

More information

User s Guide for Climatronics HazView

User s Guide for Climatronics HazView User s Guide for Climatronics HazView 140 Wilbur Place Bohemia, NY 11716 Phone (631) 567-7300 Fax (631) 567-7585 Email: sales@climatronics.com Record of Changes Date Revision Description of Change February

More information

MiTV User Manual Revision 2 July 8, 2015 Prepared by Walter B. Schoustal MicroVideo Learning Systems, Inc.

MiTV User Manual Revision 2 July 8, 2015 Prepared by Walter B. Schoustal MicroVideo Learning Systems, Inc. MiTV User Manual Revision 2 July 8, 2015 Prepared by Walter B. Schoustal MicroVideo Learning Systems, Inc. http://www.microvideo.com 1 The MiTV Video Scheduling System allows you to schedule and stream

More information

Data Manager Installation and Update Instructions

Data Manager Installation and Update Instructions Data Manager Installation and Update Instructions These instructions describe how to update or install Data Manager desktop software from YSI s website. Failure to follow these instructions may cause you

More information

Installation and Configuration Guide

Installation and Configuration Guide Installation and Configuration Guide 2013 DataNet Quality Systems. All rights reserved. Printed in U.S.A. WinSPC and QualTrend are registered trademarks of DataNet Quality Systems. All other trademarks

More information

IMS AMS 111 II. Automatic Weather Station. Easy and reliable weather monitoring anywhere

IMS AMS 111 II. Automatic Weather Station. Easy and reliable weather monitoring anywhere IMS II Automatic Weather Station Easy and reliable weather monitoring anywhere IMS Automatic Weather Station FEATURES: Synoptic Observation Climatological Observation Environmental Monitoring Radiation

More information

Multifunction instrument AMI 310

Multifunction instrument AMI 310 Multifunction instrument AMI 310 Table of contents 1 Presentation...6 1.1 Instrument description...6 1.2 Remove battery...7 1.3 Insert SD card...7 2 Connections of the AMI310...8 2.1 Main features...8

More information

User Interface: Simple Model of Atmospheric Radiative Transfer of Sunshine

User Interface: Simple Model of Atmospheric Radiative Transfer of Sunshine User Interface: Simple Model of Atmospheric Radiative Transfer of Sunshine April 2003 WINDOWS Version Introduction This document provides instructions for installing and running the User Interface for

More information

NRG INSTRUCTIONS Using the SPN1 Pyranometer on Symphonie Loggers

NRG INSTRUCTIONS Using the SPN1 Pyranometer on Symphonie Loggers INTRODUCTION This application note provides information for using the Delta T SPN1 pyranometer with NRG Symphonie loggers. The Delta-T SPN1 Thermopile based pyranometer provides signals for Global Horizontal

More information

POWERSOFT THE CONFIGURATOR Instructions for the system configuration and synoptic setup

POWERSOFT THE CONFIGURATOR Instructions for the system configuration and synoptic setup POWERSOFT THE CONFIGURATOR Instructions for the system configuration and synoptic setup Version 09/09 Rel. 2.1.0.4 INDEX 1 THE CONFIGURATOR... 3 1.1 What the configurator is... 4 1.2 The configurator functions...

More information

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement TP32MTT.03 [ GB ] Probes for soil thermal profile measurement [ GB ] [ GB ] Description Temperature measurement at 7 levels (TP32MTT.03) or 6 levels () In accordance with the requirements of the World

More information

The SolarTrak Prospector. CR-1000 Datalogger

The SolarTrak Prospector. CR-1000 Datalogger May 26, 2011 The SolarTrak Prospector Instructions for Wiring and Data Collection Using the CR-1000 Datalogger by Campbell Scientific, Inc. Complete information on the use and options for the CSI CR-1000

More information

ibidi PumpControl Instruction Manual Version 1.5.0

ibidi PumpControl Instruction Manual Version 1.5.0 ibidi PumpControl Instruction Manual Version 1.5.0 II ibidi GmbH 2011, version 1.5.0, revision 2, 2011-10-26, Andreas Rainer Table of contents 1 General Information... 1 1.1 System Requirements... 1 1.2

More information

irc Pro (Not for diagnostic use)

irc Pro (Not for diagnostic use) irc Pro (Not for diagnostic use) User guide 2016 2 Table of Contents ircpro... 3 Overview... 3 Release notes... 4 Requirements... 5 Setup... 6 Setup by DVD... 7 Setup by Internet... 8 step 1 - Install

More information

IMPLEMENTATON OF SOUTHASIA CLIMATE ASSESSMET AND DASET (SACA&D) AT BMKG

IMPLEMENTATON OF SOUTHASIA CLIMATE ASSESSMET AND DASET (SACA&D) AT BMKG IMPLEMENTATON OF SOUTHASIA CLIMATE ASSESSMET AND DASET (SACA&D) AT BMKG OUTLINE Introduction of SACAD System Preparation of Implementation Data collecting and reformatting Preparing HW,SW and BW Current

More information

Superview INSTRUCTIONS. Version 2.0x

Superview INSTRUCTIONS. Version 2.0x INSTRUCTIONS Version 2.0x INDEX INDEX... 1 INTRODUCTION... 2 INSTALLING SUPERVIEW... 3 SYSTEM REQUIREMENTS... 3 INSTALLATION PROCEDURES... 3 FIRST STEPS... 4 CREATING A SIMPLE APPLICATION... 4 Start...

More information

Tutorial. 1CLIMSOFT vers 3.2

Tutorial. 1CLIMSOFT vers 3.2 1CLIMSOFT vers 3.2 Tutorial Written by Myles Kirk-Gushowaty, Incisive Services Group Samuel M. Machua, Kenya Meteorological Service & Cathy Garlick, Statistical Services Centre June 2014 1 CLIMSOFT is

More information

BIOMA USER MANUAL VERSION

BIOMA USER MANUAL VERSION BIOMA USER MANUAL VERSION 2.2.1304 VIENNA UNIVERSITY OF TECHNOLOGY, JULY 2013 Vienna University of Technology Institute for Water Quality, Resources and Waste Management A-1040 Wien, Karlsplatz 13/226

More information

IMS CLDB and EnviDB. Universal & Reliable Climate Database Management System. IMS CLDB and EnviDB Climatological and Integrated Environmental Database

IMS CLDB and EnviDB. Universal & Reliable Climate Database Management System. IMS CLDB and EnviDB Climatological and Integrated Environmental Database Scalable solution: cost effective LITE version full-featured CDMS* with variety of optional modules available cloud solution High Availability Option Manual or Automatic Data Sources Highly Configurable

More information

User Manual JofraCal for JOFRA Temperature, Pressure and Signal Calibrators. Copyright 2004 AMETEK DENMARK A/S

User Manual JofraCal for JOFRA Temperature, Pressure and Signal Calibrators. Copyright 2004 AMETEK DENMARK A/S User Manual JofraCal for JOFRA Temperature, Pressure and Signal Calibrators Copyright 2004 AMETEK DENMARK A/S 2 124918 01 LIST OF CONTENTS Page 1. INTRODUCTION... 11 1.1 General information... 12 1.2 Hardware

More information

PTU300 Combined Pressure, Humidity and Temperature Transmitter

PTU300 Combined Pressure, Humidity and Temperature Transmitter PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface

More information

Installation and Configuration Guide

Installation and Configuration Guide Installation and Configuration Guide Copyright 2009 DataNet Quality Systems. All rights reserved. Printed in U.S.A. WinSPC and QualTrend are registered trademarks of DataNet Quality Systems. All other

More information

Installing TAM Air Assistant Software TM

Installing TAM Air Assistant Software TM Installing TAM Air Assistant Software TM Installation Instructions This document describes how to make a new installation of TAM Air Assistant. TAM Air Assistant is intended to be installed on a PC running

More information

Summary of Server Installation

Summary of Server Installation Summary of Server Installation In the following exercises, these are the steps that you will perform to install Offline V2 on a server: Exercise 1 Step 1. Step 2. Step 3. Verify Hardware Requirements Before

More information

SUMMARY. Minimum required configuration... Software installation... User logo customisation... Software Un-installation... Launching application...

SUMMARY. Minimum required configuration... Software installation... User logo customisation... Software Un-installation... Launching application... 1 SUMMARY I. Installation procedure...3 A B C D E Minimum required configuration... Software installation... User logo customisation... Software Un-installation... Launching application... 3 3 3 3 3 II.

More information

9936A LogWare III. User s Guide. Revision

9936A LogWare III. User s Guide. Revision 9936A LogWare III User s Guide Revision 680301 Table of Contents 1 Introduction... 1 1.1 Symbols Used...1 1.2 Conventions...1 1.3 What is LogWare?...1 1.4 License Agreement...2 1.5 Requirements...2 1.6

More information

X-Log Expert Data Logger

X-Log Expert Data Logger > data loggers X-Log Expert Data Logger Highlights Built-in internet stack with web server Setup and data display by any web browser Data-Push to up to three different FTP sites Internal FTP site for easy

More information

SYNERGY. Supervision and energy management software INSTRUCTION MANUAL

SYNERGY. Supervision and energy management software INSTRUCTION MANUAL SYNERGY Supervision and energy management software INSTRUCTION MANUAL INDEX 1 INTRODUCTION... 4 2 HARDWARE AND SOFTWARE REQUIREMENTS... 4 3 SETUP... 4 4 SYNERGY LOGIN AND USERS... 5 4.1 Users... 5 4.2

More information

The WMO table driven codes: The 21 st century universal observation codes

The WMO table driven codes: The 21 st century universal observation codes The WMO table driven codes: The 21 st century universal observation codes Luis Kornblueh Max-Planck-Institut für Meteorologie p.1/11 Introduction Unified meteorological observation data handling: BUFR

More information

QUALITY CONTROL FOR UNMANNED METEOROLOGICAL STATIONS IN MALAYSIAN METEOROLOGICAL DEPARTMENT

QUALITY CONTROL FOR UNMANNED METEOROLOGICAL STATIONS IN MALAYSIAN METEOROLOGICAL DEPARTMENT QUALITY CONTROL FOR UNMANNED METEOROLOGICAL STATIONS IN MALAYSIAN METEOROLOGICAL DEPARTMENT By Wan Mohd. Nazri Wan Daud Malaysian Meteorological Department, Jalan Sultan, 46667 Petaling Jaya, Selangor,

More information

Personal Radiation Detectors Data Collection and Processing Software User Guide

Personal Radiation Detectors Data Collection and Processing Software User Guide Personal Radiation Detectors Data Collection and Processing Software User Guide Introduction... 2 Getting Started... 3 Software Setup... 4 Program Settings... 5 Instrument Setup... 7 Instrument Settings...

More information

PerTrac Analytical Platform. SQL Version Setup Guide

PerTrac Analytical Platform. SQL Version Setup Guide SQL Version Setup Guide PerTrac Analytical Platform SQL Version Setup Guide Version 7.3.x March 21, 2013 TABLE OF CONTENTS SECTION 1: INSTALLATION OVERVIEW 3 SECTION 2: SINGLE USER INSTALLATION LAYOUTS

More information

CONTROL Installation and Basic-configuration Guide Contents

CONTROL Installation and Basic-configuration Guide Contents CONTROL Installation and Basic-configuration Guide Contents Installation and Basic-configuration Guide... 1 1. Overview... 2 2. Intro... 3 3. CONTROL installation steps:... 3 3.1 CONTROL installation requirements...

More information

BQS User Guide For Online (Hosted) Approved Centres

BQS User Guide For Online (Hosted) Approved Centres BQS User Guide For Online (Hosted) Approved Centres April 2013 v3.0 Contents 1. Getting Started... 3 1.1 Administration... 3 1.2 Automated Testing Software... 3 2. BQS Web Administration... 4 2.1 The Login

More information

Implementation of a PC-based data-logger software for air pollution monitoring networks

Implementation of a PC-based data-logger software for air pollution monitoring networks Air Pollution XIII 455 Implementation of a PC-based data-logger software for air pollution monitoring networks G. Latini 1, L. Magnaterra 1, S. Tascini 1 & G. Cencioni 2 1 Dipartimento di Energetica Università

More information

HD32.1. Thermal Microclimate ENGLISH

HD32.1. Thermal Microclimate ENGLISH REV. 1.3 Nov. 03 th 2009 HD32.1 Thermal Microclimate ENGLISH The Basic Kit for microclimate analysis is composed of: HD32.1 with the Operating Program A: Microclimate Analysis software DeltaLog10 - Moderate

More information

HD32MTLogger Software Manual for the instrument HD32MT.1 Introduction

HD32MTLogger Software Manual for the instrument HD32MT.1 Introduction HD32MTLogger Software Manual for the instrument HD32MT.1 Introduction WARNING: The software must always be run as administrator! The HD32MTLogger program allows management of the HD32MT.1 datalogger from

More information

Network Management Utility

Network Management Utility 4343-7705-02 Network Management Utility Foreword Welcome Network Management Utility is utility software that provides central control over printers, copiers, and other devices on a network. With Network

More information

Oracle SQL. murach s. and PL/SQL TRAINING & REFERENCE. (Chapter 2)

Oracle SQL. murach s. and PL/SQL TRAINING & REFERENCE. (Chapter 2) TRAINING & REFERENCE murach s Oracle SQL and PL/SQL (Chapter 2) works with all versions through 11g Thanks for reviewing this chapter from Murach s Oracle SQL and PL/SQL. To see the expanded table of contents

More information

CipherLab Workstation Setup (Windows 7/8/10)

CipherLab Workstation Setup (Windows 7/8/10) CipherLab Workstation Setup (Windows 7/8/10) These installation instructions will step you through setting up the CipherLab docking cradle and device, as well as installing the drivers and software used

More information

PRODUCT DATA. PULSE Indoor Pass-by Noise Testing Type 7793 with Optional Exterior Noise Contribution Analysis. Uses and Features

PRODUCT DATA. PULSE Indoor Pass-by Noise Testing Type 7793 with Optional Exterior Noise Contribution Analysis. Uses and Features PRODUCT DATA PULSE Indoor Pass-by Noise Testing Type 7793 with Optional Exterior Noise Contribution Analysis Pass-by measurements are mandatory for automotive manufacturers for product certification and

More information

SeeG3 Users Manual V2.00 Micro-g Solutions Inc. Erie, Colorado, USA

SeeG3 Users Manual V2.00 Micro-g Solutions Inc. Erie, Colorado, USA SeeG3 Users Manual V2.00 Micro-g Solutions Inc. Erie, Colorado, USA September, 2003 Table of Contents Table of Contents 0 Table of Contents 1 Introduction 2 System Requirements 2 Installing SeeG3 3 SeeG3

More information

Smart Garden Hub. User Guide. Revision 2.7, April

Smart Garden Hub. User Guide. Revision 2.7, April Smart Garden Hub User Guide Revision 2.7, April 2015 www.greeniq.co 1. Your GreenIQ Smart Garden Hub 1.1. Welcome Thank you for purchasing the GreenIQ Smart Garden Hub. The GreenIQ Smart Garden Hub allows

More information

GSN-KEY ACCESS CONTROL KIT FOR REPROGRAMMABLE ELECTRONIC LOCK E-PRL. User manual

GSN-KEY ACCESS CONTROL KIT FOR REPROGRAMMABLE ELECTRONIC LOCK E-PRL. User manual GSN-KEY FOR REPROGRAMMABLE ELECTRONIC LOCK E-PRL ACCESS CONTROL KIT User manual 1 INDEX General description and ACCESS CONTROL KIT contents p. 2 How to use the software p. 2 Installing Software on a local

More information

HW4 Instruction Manual

HW4 Instruction Manual HW4 Instruction Manual in-hw4-rev3.doc / 20040806 - 2 - Overview... 4 HW4 requirements... 5 Connecting a single instrument to the PC... 5 Connecting multiple instruments to the PC... 9 RS232 or USB port...

More information

GEOMATICS SYNTHESIS PROJECT SYMPOSIUM

GEOMATICS SYNTHESIS PROJECT SYMPOSIUM GEOMATICS SYNTHESIS PROJECT SYMPOSIUM Thursday 8 November, 2012 Oostserre, BKCity in association with GEOMATICS SYNTHESIS PROJECT SYMPOSIUM OVERVIEW 1. Introduction 2. Background 3. Site Description 4.

More information

St art. rp m. Km /h 1: : : : : : : : : : : : :5 2.5.

St art. rp m. Km /h 1: : : : : : : : : : : : :5 2.5. modified 02/12/15 t 3:5 2.5 3:5 5.0 3:5 7.5 4:0 0.0 4:0 2.5 4:0 5.0 4:0 7.5 4:1 0.0 4:1 2.5 4:1 5.0 4:1 7.5 4:2 0.0 Km /h 0 25 50 75 100 125 150 175 200 225 rp m 0 250 0 500 0 750 0 100 00 125 00 1 2 3

More information

Power Vision 1.7 (Cod )

Power Vision 1.7 (Cod ) ELECTRICAL NETWORK ANALYSIS SOFTWARE Power Vision 1.7 (Cod. 775 353) USER S MANUAL (Cod. M 981 358 / 05B) 2005 - CIRCUTOR, S.A. INDEX 1.- POWER VISION SOFTWARE INSTALLATION...4 2.- INTRODUCTION TO POWER

More information