1 INSTLLTI ND OPERTING INSTRUCTIS Lightgate MixedWhite TP-MW-01/W/WM/NFC

2 General short description In conjunction with the LGC-MW-01/L/plus MixedWhite controller, the touchpanel is used to control the colour temperature and brightness of lighting systems. It has an RFID transponder on the back and a light-sensitive diode for programming the system via a smartphone. status LED is also integrated. There are two DIP switch rows on the back of the touchpanel as well as a 4-pole connection terminal for the voltage supply and data connection. The standard parameter set which is stored in the device can be viewed in the smartphone app and adapted to individual requirements. Parameterisation of the system The operating parameters are set using a smartphone app. The data is transmitted via near field communication (NFC) or light pulses (LIP). NFC The data is transferred via an NFC-enabled smartphone. For transmission, the RFID transponder integrated in the smartphone must be held at a distance of approx. 0.5 cm above the RFID transponder on the back of the touchpanel (Pos. 13). Most smartphones have their transponders integrated on the back. fter successful transmission, the Settings have been successfully transferred message appears on the smartphone. In addition, the LED in the touchpanel (Pos. 1) flashes 20 times and the lighting system flashes 3 times for confirmation. LIP The transmission of the data takes place via light pulses, which are generated using the flash light LED of the smartphone. For transmission, the flash light LED of the smartphone must be held at a distance of approx. 3 cm above the receiving diode (Pos. 4) on the front of the touchpanel. fter successful transmission, the automatic/ manual LED flashes 20 times in the touchpanel (Pos. 1) and the lighting system flashes 3 times for confirmation. utomatic mode In automatic mode the system is controlled via parameters that are settable in the app, in accordance with time/ calculated position of the sun and/or sensors. The setting of the parameters and their functions are described in detail in the app and in their operating instructions. Manual mode In manual mode, the unit is operated via 1 or 2 connected wall buttons, which can be set via the smartphone app. Switching between automatic and manual mode can be performed automatically by switching times or by connected wall buttons. 2

3 Front touchpanel Control panel of the touchpanel on the front Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pos. 5 Pos. 6 Pos. 7 Pos. 8 Pos. 9 LED indicator: utomatic LED indicator: On LED indicator: Off Receiving diode for data transmission Touchpad: utomatic / Manual Touchpad: On Touchpad: Off Slider: rightness Slider: Colour temperature Please note: fter switching the power off and on again, please do not touch the touchpanel for 15 seconds. calibration takes place. Controls and indicators Pos. 1 LED indicator: utomatic LED lights up when the system works in the automatic mode. The LED is off in manual mode. It flashes 20 times if the transfer of the parameters from the smartphone was successful. Pos. 2 LED indicator: On LED lights up when the luminaires are switched on. Pos. 3 LED indicator: Off LED lights up if the luminaires are switched off. Pos. 4 Receiving diode for data transmission Receiver for programming via the flash light LED of a smartphone. Pos. 5 Touchpad: utomatic/manual Switches between automatic and manual mode. The selected mode is shown by the utomatic indicator (Pos. 1). In automatic mode, the LED lights up, in manual mode it is off. Pos. 6 Touchpad: On Switches the luminaires on in automatic mode. The operating status is displayed via the LED indicator On (Pos. 2) and the LED indicator utomatic (Pos. 1). Pos. 7 Touchpad: Off Switches the luminaires off. The operating status is displayed via the LED indicator Off (Pos. 3). Pos. 8 Slider: rightness The brightness of the luminaires is set via the slider. The further up the slider is moved, the brighter the luminaires become. Moving the slider in the lower range reduces the brightness of the luminaires. Via the slider, the brightness can be changed similar to a slide control. The automatic mode stays activated. Pos. 9 Slider: Colour temperature The colour temperature of the luminaires is adjusted by moving the slider. The further upward the slider is moved, the warmer the colour tone of the light. Moving the slider in the lower range changes the colour tone towards a cold white. Via the slider, the colour tone can be changed similar to a slide control. The automatic mode is also terminated. 3

4 Reverse side of the touchpanel Rear view of the touchpanel 13 Pos. 10 Connection socket (RS-485 US) version: Phoenix PTSM 4-pin Pos. 11 DIP switch rows 1 Pos. 12 DIP switch rows 2 Pos. 13 NFC reception range for data transmission Connection of the touchpanel In order to connect the controller with the touchpanel, please proceed as follows. 1. Fit the Phoenix connector by inserting the stripped wires. 2. Plug the corresponding side of the Phoenix connector into the connector socket (Pos. 10) on the reverse side of the touchpanel. 3. Likewise, wire the connection adapter with the individual wires of the cable (please observe the polarity). 4. The adapter is finally connected to the controller via the RJ10 cable (included). max. 100 m (2 x 2 x 0,8 mm 2, rigid) Connecting adapter RJ10-Kabel Phoenix connector Controller Top view of Phoenix connector Openings for cables Openings for release bolt 4

5 Connection Function of the DIP switch row 1 (Pos. 11) Up to 3 touchpanels can be connected to a controller. For this, the following settings are necessary on the individual touchpanels: Use of one touchpanel Touch 1 Use of two touchpanels Default setting (state as delivered) Touch 1 (Master) Touch 2 (Slave) Wiring diagram (Master) TP-MW-01/W/WM (Slave 1) TP-MW-01/W/WM (Slave 2) TP-MW-01/W/WM Controller LGC-MW-01/ L/plus Use of three touchpanels Please note: It is not possible to connect a touchpanel to several controllers. Touch 1 (master) Touch 2 (slave 1) Touch 3 (slave 2) Function of the DIP switch row 2 (Pos. 12) The positions of the DIP switches have the following meanings: Demo mode is activated. The 24 hour cycle will run within 5 min. Locking the respective parameters prevents unauthorised changes to the basic setting of the controller. The switch positions can be combined as desired. In the delivery state, all switches are set to OFF. Locking the settings parameter Locking of the switching times and circadian curves parameter Locking the set time parameter Locking the brightness of the status LED

6 Installation Installation Similar to a standard flush-mounted switching element, the enclosed mounting frame is fixed to the flush-mounted socket using two screws. Together with the frame with the snap-in lugs, the touchpanel is inserted into the designated holes (marked in red) of the mounting frame. Technical specifications Designation Order number TP-MW-01/W/WM/NFC Specifications Type of installation Surface mounting with an attached fixing ring on standard flush-mounted sockets 9-24 VDC SELV max. 30 m Supply voltage Power input mbient temperature ta C Max. cable length of the controller touchpanel 100 m (recommendation 2 x 2 x 0.8 mm 2 ) Connection type Plug-in terminal block max. 0.8 mm 2 rigid, 6 mm stripped Dimensions (L x W x H) with a frame 160 mm x 90 mm x 23 mm depending on the switch frame type Dimensions (L x W x H) component without a frame, with a connector 127 mm x 55.6 mm x 22 mm Weight 65 g Operating modes utomatic and manual mode Humidity % relative humidity, non-condensing Protection class IP 20 ccessories Packing contents Optional GIR frame, 4-pin connector (Phoenix PTSM), mounting frame for flush mounting socket RJ10 cables in different lengths, RJ10-Y distributors, RJ10 connectors 6

7 OEM Systems Group G electronics GmbH Kleinbahnstraße 27 D rnsberg Tel.: Fax: operating instructions We reserve the right to make technical changes.

Access Terminal IF-800

Access Terminal IF-800 95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller

More information

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information RM Series Modbus Digital Remote I/O Modbus Connector Type Digital Remote I/O Features Modbus RTU standard protocol Connects with sensor connector, e-con: saves wiring work (sensor connector, CNE Series,

More information

Light Source User Guide

Light Source User Guide Light Source User Guide Vega Slimline Plastic Light Source Range Models covered by this manual: UFO VEGA SLP-2700M UFO VEGA SLP-3000M UFO VEGA SLP-4000M UFO VEGA SLP-2700DMX UFO VEGA SLP-3000DMX UFO VEGA

More information

Blu2Light Light Management Installation in Luminaires

Blu2Light Light Management Installation in Luminaires BLUETOOTH WIRELESS TECHNOLOGY DEVICES FOR INSTALLATION IN LUMINAIRES BLUETOOTH WIRELESS TECHNOLOGY DEVICES FOR INSTALLATION IN LUMINAIRES Blu2Light The intelligent wireless lighting control solution Blu2Light

More information

K107A / K107B Half-duplex RS485 serial bus with 3-point insulation

K107A / K107B Half-duplex RS485 serial bus with 3-point insulation 0 0 K0 R THE INTERNATIONAL CERTIFICATION NETWORK EN K0A / K0B Half-duplex RS serial bus with -point insulation General Description The K0A and K0B modules are half duplex serial buses with -point insulation.

More information

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions Smart Control IP Art. No. SC 1000 IP Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property

More information

Light Source User Guide

Light Source User Guide Light Source User Guide MicroLED Light Source Range Models covered by this manual: UFO MIC4000P Please read this manual fully before installing, operating or performing maintenance on the light source

More information

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX User Manual MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX CE MARKING This equipment complies with the requirements relating to electromagnetic compatibility, EN 55022 class A for ITE, the

More information

LinkRay LED Drivers EasyLine With Selectable Current , Typical Applications

LinkRay LED Drivers EasyLine With Selectable Current , Typical Applications MUSIUM RESTAURANT SOUVENIR SHOP EXIT LinkRay-LED Drivers EasyLine With Selectable Current LINK RAY LED DRIVERS EasyLine MultiCurrent LinkRay LED DRIVERS EasyLine WITH SELECTABLE CURRENT LinkRay LED Drivers

More information

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! TUC2 / TUCH2 Model Series Installation Instructions PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! APPLICATION The TUC2 provides temperature space monitoring with a backlit LCD. The TUCH2 provides

More information

Light Source User Guide

Light Source User Guide Light Source User Guide MicroLED Light Source Range Models covered by this manual: UFO MIC3000 Please read this manual fully before installing, operating or performing maintenance on the light source unit.

More information

B.IQ push button comfort 1-4gang, Flush-mounted (Up) x, x, x, x

B.IQ push button comfort 1-4gang, Flush-mounted (Up) x, x, x, x The B.IQ push-button comfort is plugged onto a flushmounted bus coupling unit (flush-mounted BCU). The push-buttons of the device can be programmed for the following functions: switching, dimming, blind/shutter

More information

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type designation Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100

More information

IF-80x Outdoor Terminal

IF-80x Outdoor Terminal 95-10330_IF-800 V2016-10-20 Outdoor Terminal IF-80x Outdoor Terminal 1 IF-800 Outdoor / IF-801 We are pleased that you have decided to use a terminal of the IF-80x series for recording access data. Scope

More information

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T User Manual MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T CE MARKING This equipment complies with the requirements relating to electromagnetic compatibility, EN 55022 class A for ITE,

More information

4 Channel DMX Driver Instruction Manual

4 Channel DMX Driver Instruction Manual LEDstuff.co.nz 4 Channel DMX Driver Instruction Manual Quality LED Lighting Products The LEDstuff 4 Channel DMX Driver is a flexible module that is an ideal addition to an existing home automation or lighting

More information

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815 95-10324_V2016-11-23 IF-812/IF-815 1 IF-812 or IF-815 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-812 or IF-815 terminal (slave), you have purchased a reliable device for capturing

More information

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3 THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Digi-modems Issue 3 Contents Com300 & Com2400 Installation Manual Contents 1. Regulatory Requirements... 3 General...3 Approval... 3 REN Rating... 3 2.

More information

Ethernet Adapter Installation Instructions

Ethernet Adapter Installation Instructions Ethernet Adapter Installation Instructions DOC. #569040000 A 7/30/04 PRINTED IN U.S.A. Disclaimer Logic One is a registered trademark of Novar Controls Corporation. The material in this manual is for information

More information

User Manual. PCKeypad Wireless Keypad

User Manual. PCKeypad Wireless Keypad User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option

More information

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions Mounting and operating instructions Table of contents SFETY ND PRECUTIONS 3 PRODUCT DESCRIPTION 4 RTICLE CODES 4 INTENDED RE OF USE 4 TECHNICL DT 4 STNDRDS 4 WIRING ND CONNECTIONS 5 MOUNTING INSTRUCTIONS

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439 MODEL DSU-56 56 Kbps Rack Mount CSU/DSU OPERATOR S MANUAL 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439 TEL: 775-345-8000 FAX: 775-345-8010 E-MAIL: SUPPORT @S.NET DSU-56 Rack Mount TABLE OF CONTENTS

More information

Mounting DIGITAL DISPLAY

Mounting DIGITAL DISPLAY Mounting The Class digital display mounts in a. by. cutout. Overall area necessary for installation is. by.. Two 0.0 diameter holes are provided for mounting screws..0".0..0.900 Ø 0.0" () HOLES."." DIGITAL

More information

Bus coupler 3 Bus coupler 3 external sensor Order No

Bus coupler 3 Bus coupler 3 external sensor Order No KNX Product documentation Issue: 28.07.2017 20083200 Bus coupler 3 Bus coupler 3 external sensor Table of Contents KNX Product documentation 1 Product definition... 3 1.1 Product catalogue... 3 1.2 Function...

More information

CPT-COM-U Card. TTL Serial USB Isolated Interface Board. Technical Brief

CPT-COM-U Card. TTL Serial USB Isolated Interface Board. Technical Brief CPT-COM-U Card TTL Serial USB Isolated Interface Board Technical Brief June 2014 Manual Release 1.0 Card Version 1.1 Copyright 2014 Creative Power Technologies P/L P.O. Box 714 MULGRAVE Victoria, 3170

More information

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL 200 VA bis 3.120 VA 10 V bis 80 V 2 A bis 320 A NL AC, NL Series Interface overview RS-232 X USB X GPIB O LAN O System bus O Analog X Analog isolated O X Standard O Option / not available NL1V20C40 2-quadrant

More information

LCC1653/01, LRI1653/01 ActiLume DALI System

LCC1653/01, LRI1653/01 ActiLume DALI System 1/8 Product description The Philips ActiLume lighting control system consists of a small, lightweight sensor and controller, designed for easy integration into luminaires. ActiLume is a true Plug and Play

More information

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2 Type designation Ident no. 1545069 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100

More information

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811 95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing

More information

DPM-3221 Digital DC Power Meter with data logging capability.

DPM-3221 Digital DC Power Meter with data logging capability. Introduction DPM-3221 Digital DC Power Meter with data logging capability. User Manual As a digital DC power meter, it measures the real time DC Voltage (5-60V), DC Current (0-200 A with the correct shunt),

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information

CTT. Standard equipment. ATP color NP. ø5 (red, blue, white, black, green, and yellow) 1 2 (6P, 8P) Applicable plugs ATP-A,ATQ-A PTT

CTT. Standard equipment. ATP color NP. ø5 (red, blue, white, black, green, and yellow) 1 2 (6P, 8P) Applicable plugs ATP-A,ATQ-A PTT INSERTION TYPE TEST TERMINS STNDRD MODES (TERMIN) TT- -TYPE (For current) Circuit opening prevention type CTT 19 44 20 0 11.5 7 6 (7.) 12 10 8 6 4 2 11 9 7 5 1 M.5 7 9 48 57 75 9 Standard equipment Min.

More information

LED Dimmer LED-08T

LED Dimmer LED-08T Dimmer -08T General The dimmer was especially developed to control s in ground plan touch pads. For the fi rst time this device enables you to control the brightness of s between 0 and 100% so that it

More information

Programmable Set for Simple I/O Communication via PROFIBUS-DP in IP67 TI-BL67-PG-DP-S-8

Programmable Set for Simple I/O Communication via PROFIBUS-DP in IP67 TI-BL67-PG-DP-S-8 Type designation Ident no. 1545097 Number of channels 8 Dimensions (W x L x H) 204 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 12 Mbps

More information

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) Product Information DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Phone +49.2355.806-0 Fax +49.2355.806-189 E-Mail:

More information

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual Zartek CDP-808 Two Button Wireless Intercom Installers Manual ZA-614 Two Button Gate station including power supply, relay board and external antenna ZA-613 Handsets with charger ZA-613-E Handsets with

More information

Nova Light Source Range

Nova Light Source Range Light Source User Guide Nova Light Source Range Models covered by this manual: UFO NOVA DMX UFO NOVA DMX-R UFO NOVA DMX-T UFO NOVA DMX-TR Please read this manual fully before installing, operating or performing

More information

System Components Surge Arrester HAW 261 and HAW 262

System Components Surge Arrester HAW 261 and HAW 262 Technical Information TI 108F/00/en System Components Surge Arrester and Operating Instructions Part. No. 017166-1000 for power supply side for signal input side (2-wire) (2 and 3-wire) Application The

More information

Technical Description

Technical Description B Content 1. Allgemeines...1 2. Blockdiagramm...2 3. Inbetriebnahme...2 4. Technische Daten...3 4.1 AS-Interface...3 4.2 Anschlussbelegung...3 4.3 LED Anzeige...4 4.4 Mechanische und Umgebungsdaten...4

More information

Printheads HP TIJ 2.5

Printheads HP TIJ 2.5 Printheads HP TIJ 2.5 Premium New Premium printheads for use with a series of new printer controllers utilizing the HP TIJ 2.5 technology HSAJET and HP TIJ 2.5 technology HSAJET printers use HP thermal

More information

Orbis MU 41. Digital Flush Mount Delegate Microphone Unit Order #

Orbis MU 41. Digital Flush Mount Delegate Microphone Unit Order # Digital Flush Mount Delegate Microphone Unit Order # 725.722 Optional CA OL loudspeaker module, not included Table installation supplied without gooseneck microphone FEATURES High-quality flush mounting

More information

Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM)

Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM) Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM) FIBER-OPTIC OXYGEN METER OEM-MODULE WITH UART-INTERFACE MANUAL Document Version 1.04 The Piccolo2-OEM is manufactured by PyroScience GmbH Hubertusstr.

More information

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data: Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

AbstractAVR. Ledbuddy controller. Ledbuddy Panel User Manual 2009 Abstract AVR and Sabre Technology Tel:

AbstractAVR. Ledbuddy controller. Ledbuddy Panel User Manual 2009 Abstract AVR and Sabre Technology Tel: Ledbuddy Panel User Manual 2009 Abstract AVR and Sabre Technology Tel: 0116 278 8078 http://www.abstractavr.com AbstractAVR Ledbuddy controller Page 12 Introduction The LedBuddy is a simple yet powerful

More information

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376 Supplementary instructions Plug connector Harting HAN 8D for continuously measuring sensors Document ID: 30376 Contents Contents 1 For your safety 1.1 Appropriate use... 3 1.2 Impermissible use... 3 1.3

More information

STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK

STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK The Studio 1800 is a combined Programmer and Temperature Controller which has been specifically designed for use with pottery kilns. Control of

More information

Light Source User Guide

Light Source User Guide Light Source User Guide Mercury Slimline Light Source Range Models covered by this manual: UFO MERSL3000M UFO MERSL 3000DMX UFO MERSL 3000 0-10V Please read this manual fully before installing, operating

More information

MOXA Industrial Media Converter

MOXA Industrial Media Converter MOX Industrial Media Converter IMC-1 Hardware Installation Guide First Edition, September 005 Moxa Networking Co., Ltd. Tel: +886--910-130 Fax: +886--910-131 www.moxa.com support@moxanet.com (Worldwide)

More information

Product documentation

Product documentation Product documentation Universal push-button module with integrated BCU, 1-gang Universal push-button module with integrated BCU, 2-gang Universal push-button module with integrated BCU, 3-gang Universal

More information

Light Source User Guide

Light Source User Guide Light Source User Guide Micro LED4000X2 Light Source Range Models covered by this manual UFO MicroLED 4000X2 Please read this manual fully before installing, operating or performing maintenance on the

More information

Fiber optic converter audio and CAN TA OPERATION MANUAL

Fiber optic converter audio and CAN TA OPERATION MANUAL Fiber optic converter audio and CAN TA-110.1 IOA110-1 March 2009 LANEX S.A., Technical support: tel. ul.ceramiczna 8, 20-150 Lublin tel. +48 81 443 96 36 Contents 1. General Characteristics.... 5 1.1.

More information

Retrofit kit for fixed scanner/handheld scanner SVP-2D / SVP-2D/H / SVP-3 / SVP-4

Retrofit kit for fixed scanner/handheld scanner SVP-2D / SVP-2D/H / SVP-3 / SVP-4 Translation of the original manual Retrofit kit for fixed scanner/handheld scanner SVP-2D / SVP-2D/H / SVP-3 / SVP-4 Assembly and Operating Manual Superior Clamping and Gripping Imprint Imprint Copyright:

More information

Structure of the device. Push-button sensor module. Ref.-no.: 4008 TSM Safety instructions

Structure of the device. Push-button sensor module. Ref.-no.: 4008 TSM Safety instructions Push-button sensor module Ref.-no.: 4008 TSM Safety instructions Caution! Electrical devices may only be installed and fitted by electrically skilled persons. Non-compliance with the installation information

More information

62G from 1.0 from surface. K&J D x.50, N42. 69G from 1.75 from surface. 236G from 1.25 from surface.

62G from 1.0 from surface. K&J D x.50, N42. 69G from 1.75 from surface. 236G from 1.25 from surface. FX50 Datasheet Electrical Specifications Input voltage 6 26V Outputs 1 Solid State Relay, 40V (max), 2A Hall Sensor Linear Hall Sensor, AH8500 Processor NXP/Freescale ARM Cortex M0+ Magnetic Specifications

More information

Vega Decorative Light Source Range

Vega Decorative Light Source Range Light Source User Guide Vega Decorative Light Source Range Models covered by this manual: UFO VEGA - CM UFO VEGA - TM UFO VEGA - MCM UFO VEGA - MTM UFO VEGA - CDMX UFO VEGA - TDMX UFO VEGA - C 0-10V UFO

More information

OT EASY 60 II. LED control unit Operating instructions

OT EASY 60 II. LED control unit Operating instructions II LED control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Intended use 4 Description... 5 Function and application 5 Function 5 Important definitions

More information

660/960 Installation Guide

660/960 Installation Guide 660/960 Installation Guide Compatible Equipment 660: Any Scantronic control panel. 960: All control panels with the Scantronic plug-on footprint pins. 496354 Issue 1 1 of 16 660/960 Introduction The 660/960

More information

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T with PoE+, 1x 10/100/1000Base-T or 100/1000Base-X Combo Port, 1x 100/1000Base X SFP Slot General The IP protocol has already left the

More information

u::lux Switch RJ45 Manual u::lux Switch RJ45 Manual Tel: +43/662/ Fax: +43/662/

u::lux Switch RJ45 Manual u::lux Switch RJ45 Manual  Tel: +43/662/ Fax: +43/662/ u::lux Switch RJ45 Manual www.u-lux.com office@u-lux.com Tel: +43/662/450 351-13 Fax: +43/662/450 351-16 u::lux GmbH Rechtes Salzachufer 42 5020 Salzburg Austria Page: 1/11 Contents Installation... 3 Installation

More information

LIFEBUOY RELEASE SYSTEM - TECHNICAL PRODUCT SPECIFICATION AND INSTALLATION MANUAL

LIFEBUOY RELEASE SYSTEM - TECHNICAL PRODUCT SPECIFICATION AND INSTALLATION MANUAL LIFEBUOY RELEASE SYSTEM - TECHNICAL PRODUCT SPECIFICATION AND INSTALLATION MANUAL The LifeBuoy Remote Release System standard HM-0600 consists of the following parts: One GRP holder with pre-installed

More information

Supplementary instructions. Plug connector ISO for continuously measuring sensors. Document ID: 30375

Supplementary instructions. Plug connector ISO for continuously measuring sensors. Document ID: 30375 Supplementary instructions Plug connector ISO 4400 for continuously measuring sensors Document ID: 30375 Contents Contents For your safety. Appropriate use... 3.2 Impermissible use... 3.3 General safety

More information

Electronic Multi-channel Load PMLA. 150 W / 600 W 40 V up to 240 V 1 A up to 120 A. Preliminary Edition

Electronic Multi-channel Load PMLA. 150 W / 600 W 40 V up to 240 V 1 A up to 120 A. Preliminary Edition Electronic Multi-channel Load PMLA 150 W / 600 W 40 V up to 240 V 1 A up to 120 A Preliminary Edition Functionality Interface Overview Master RS-232 X CAN O USB X Analog O LAN X Analog isoliert / GPIB

More information

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380 Supplementary instructions Plug connector ISO 4400 for level sensors Document ID: 30380 Contents Contents For your safety. Appropriate use... 3.2 General safety instructions... 3.3 Safety instructions

More information

IQ3/XNC M-Bus Master

IQ3/XNC M-Bus Master IQ3/XNC M-Bus Master Installation, configuration and error handling Version 2.8b 15. mar. 2011 Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel : +45 8880 7580 www.electrocom.dk p. 2 1. XNC M-Bus

More information

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10 4070.83/4--10 PumpDrive DPM Installation and Operating Instructions Dual Pump Module (DPM) These installation and operating instructions are not valid on their own. They must always be applied in conjunction

More information

BA/BS4S Temperature Sensor Installation & Operating Instructions

BA/BS4S Temperature Sensor Installation & Operating Instructions Product Overview and Identification The BAPI-Stat 4 room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication jack.

More information

Product documentation

Product documentation Product documentation Standard push-button module with BCU, 2-gang ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 D-58579 Schalksmühle Telefon: +49.23 55.8 06-0 Telefax: +49.23 55.8 06-1 89 E-mail: mail.info@jung.de

More information

Product documentation

Product documentation Product documentation Standard push-button module with BCU, 4-gang ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 D-58579 Schalksmühle Telefon: +49.23 55.8 06-0 Telefax: +49.23 55.8 06-1 89 E-mail: mail.info@jung.de

More information

SUNCLIX Connection technology for photovoltaics

SUNCLIX Connection technology for photovoltaics SUNCLIX Connection technology for photovoltaics Connection technology for photovoltaics Are you looking for innovative and reliable connection technology for your PV modules, inverters or the complete

More information

B.IQ push button 3gang, Flush-mounted (Up) x

B.IQ push button 3gang, Flush-mounted (Up) x The application module for pushing onto the flush-mounting bus coupling unit. Depending on the user software can trigger switch actuators, or dim actuators or shutter actuators, and can also be used as

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation d e v e l o p i n g s o l u t i o n s DE43 Data sheet Digital 2-channel transmitter for direct connection to bus-capable automation devices The bus-capable 2-channel transmitter is suitable for measuring

More information

HZS 351 Room Touch Control Panel

HZS 351 Room Touch Control Panel HZS 351 Room Touch Control Panel Date of creation: 13.03.2014 Version date: 25.03.2016 Article number: 06-895-351-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18

More information

UR51 Industrial Cellular Router

UR51 Industrial Cellular Router UR51 Industrial Cellular Router Quick Start Guide 1 Ursalink Technology Co., Ltd. Welcome Thank you for choosing Ursalink UR51 industrial cellular router. This guide describes how to install the UR51 and

More information

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC ERP no.: 5206415 GCM MOD GMM EC.1 www.guentner.de Page 2 / 15 Contents 1 GCM MOD GMM EC.1...3 1.1 Functional description...3 1.2 Connections...

More information

HUMLOG 10. Manual. Status V4 (02/2010)

HUMLOG 10. Manual. Status V4 (02/2010) HUMLOG 10 Manual Status V4 (02/2010) Contents 1 GENERAL 3 2 DISPLAY MODULE 4 3 HUMLOG 10 WITH INTERNAL SENSORS 6 4 HUMLOG 10 TSE FOR EXTERNAL SENSORS 7 5 HUMLOG 10 THC WITH INTERNAL SENSORS/WITHOUT DISPLAY

More information

Product and Function Description

Product and Function Description Product and Function Description and the LED display. The touchscreen can be used to select from up to 6 languages for the display of texts and messages. The room temperature controller integrated in Contouch

More information

Supplementary manual UVR16x2E-DE/NP Relay versions

Supplementary manual UVR16x2E-DE/NP Relay versions Technische Alternative RT GmbH A-3872 Amaliendorf, Langestr. 124 Tel +43 (0)2862 53635 mail@ta.co.at UVR16x2E-DE UVR16x2E-NP Manual vers. 1.4 EN Supplementary manual UVR16x2E-DE/NP Relay versions Table

More information

GS202 Encoder Switch

GS202 Encoder Switch GS202 Encoder Switch 20:2 encoder switch 20 encoder inputs (TTL / RS422 standard) Input signals A, /A, B, /B, Z, /Z on each encoder input 2 x 6 control inputs (HTL / PNP) 2 encoder outputs (TTL / RS422

More information

Operating and mounting instructions

Operating and mounting instructions General Usage IPAS DALI Gateways bring together the crossfunctional KNX installation bus and the lighting control specific DALI-Bus (IEC 60929). Lights with cost-effective, digital DALI ECGs can therefore

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

Accsense Wireless System. Temperature Monitor

Accsense Wireless System. Temperature Monitor Accsense Wireless System Temperature Monitor Contents 1. Installing the B1-06 Gateway...2 2. Installing the Pods...3 3. Wiring the Pods...5 Version 1 - August 2010 29975 Page 1 1. Installing the B1-06

More information

Bus Connection Unit 560BCU04

Bus Connection Unit 560BCU04 Bus Connection Unit 560BCU04 Application The Bus Connection Unit 560BCU04 R0001 is designed to make the RTU560s TSI, TSO, Alarm and Warning signals accessible to the outside. By using the bus connection

More information

INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation

INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation SOCKET OUTLET (RJ5) Surge Arrester LAN fine protection for fixed installation Protection for all lines Shielded socket outlet, Category 5 Data socket outlet (Category 5) with integrated surge protection.

More information

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed. Assembly Instructions scancontrol 2600/2650/2900/2950 1. Warnings Connect the power supply and the display-/output device in accordance with the safety regulations for electrical equipment. The power supply

More information

Luna Decorative Light Source Range

Luna Decorative Light Source Range Light Source User Guide Luna Decorative Light Source Range Models covered by this manual: UFO LUNA - CM UFO LUNA - TM UFO LUNA - MCM UFO LUNA - MTM UFO LUNA - CDMX UFO LUNA - TDMX UFO LUNA - C 0-10V UFO

More information

EP/2 Installation Instructions

EP/2 Installation Instructions 1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in

More information

UR72 & UR75 Industrial Cellular Router

UR72 & UR75 Industrial Cellular Router UR72 & UR75 Industrial Cellular Router Quick Start Guide 1 Ursalink Technology Co., Ltd. Welcome Thank you for choosing Ursalink UR72/UR75 industrial cellular router. This guide describes how to install

More information

Room unit with PPS2 interface

Room unit with PPS2 interface 1 642 Desigo RX Room unit with PPS2 interface for use with: QAX33.1 devices of the ranges Desigo RXC, RXB, RXL, and RXA (PPS2) Desigo PX Automation stations 1) devices with a PPS2 interface Room temperature

More information

HZS 352 Touch Room Unit

HZS 352 Touch Room Unit HZS 352 Touch Room Unit Date of creation: 25.04.2014 Version date: 25.03.2016 Article number: 06-895-352-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18 Email:

More information

PowerView Model PV1000. Hardware Installation Manual Section 78

PowerView Model PV1000. Hardware Installation Manual Section 78 PowerView Model PV1000 Hardware Installation Manual 00-02-0599 07-19-07 Section 78 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications

More information

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable Features DMX512 Controllable and RDM Configurable Designed for driving LED strips through 6 high power 12 and 24 Volts output units available Easy addressing interface (physical switches and RDM) Isolated

More information

Controlesta RCO-Compact

Controlesta RCO-Compact Commissioning NOTICE The details contained in these documents and data can be changed without prior advance notice No part of these documents may be reproduced or passed on without the specific written

More information

mipick Pick-by-Light System

mipick Pick-by-Light System mipick Pick-by-Light System User Manual microsyst Systemelectronic GmbH Exclusive UK and Ireland Agent: Metrix Electronics Ltd tel: 0845 034 3234 www.metrix-electronics.com Index 1 SYSTEM OVERVIEW 4 2

More information

IntesisBox Modbus Server Panasonic

IntesisBox Modbus Server Panasonic IntesisBox Modbus Server - Panasonic Gateway for Panasonic ECO-i VRF and PAC-i system integration into Modbus Systems Master Up to 30 Outdoor units Up to 64 Indoor units Modbus TCP Master /EIA232 PA-AC-MBS-64/128

More information

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC KPW-T2P25 Industrial IEEE 802.3at High Power PoE Splitter User s Manual DOC.121011-1- (C) 2012 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any

More information

VENTILATION BUTTONS 24 V DC

VENTILATION BUTTONS 24 V DC VENTILATION BUTTONS 24 V DC Ventilation button (with foil push buttons and displys) Application: Ventilation button for connection to the ventilation inputs of SHEV or natural ventilation control units.

More information