1 Release Notes WireXpert / export Version 7.3 Build 854 June 1, 2017 Version: 1.0 Page 1 of 6
2 1 New or enhanced features: WireXpert / Certifier Copper cable database updated Link / Berk-Tek / Leviton /Giga Media / LEONI Kerpen / Schrack Technik / Siemon Systimax Copper connector database updated Leviton/ Giga Media / LEONI Kerpen / Schrack Technik. CCT Fiber cable / connector database updated Multimedia Connect MMC. Siemon Komos Probe names updated Class FA EC7 Channel to "MMC Pro Channel". Class FA EC7 Permanent Link to MMC Pro Permanent Link". Graphic for Wiremap updated. Retain settings on software upgrade. Cross Over Cable testing (10BASE-T / 100BASE-TX). Copper / fiber limits updated as per latest standards except Korean standards. New / Updated copper limits Cat 8 i. TIA - Cat 8 Channel 22-23AWG ii. TIA - Cat 8 Channel 24AWG iii. TIA - Cat 8 Channel 26AWG End to End Limits i. ISO - Five Connection Class D E2E Link ii. ISO - Five Connection Class E E2E Link iii. ISO - Four Connection Class D E2E Link iv. ISO - Four Connection Class E E2E Link v. ISO - Three Connection Class D E2E Link vi. ISO - Three Connection Class E E2E Link vii. ISO - Two Connection Class D E2E Link viii. ISO - Two Connection Class E E2E Link Application Standards i. 10BASE T ii. 100BASE-TX Cenelec EN Class FA Channel Page 2 of 6
3 Taiwan Standards i. EL Cat 5e Channel ii. EL Cat 5e Link iii. EL Cat 6 Channel iv. EL Cat 6 Link v. EL Cat 6A Channel vi. EL Cat 6A Link GB China Limits i. GB_T Class D Channel ii. GB_T Class D Link CP iii. GB_T Class E Channel iv. GB_T Class E Link CP v. GB_T Class EA Channel vi. GB_T Class EA Link CP vii. GB_T Class F Channel viii. GB_T Class F Link CP ix. GB_T Class FA Channel x. GB_T Class FA Link CP New / updated fiber limits TIA i. TIA ii. TIA ISP iii. TIA OSP ISO i. ISO/IEC OF-300 CH ii. ISO/IEC OF-500 CH iii. ISO/IEC OF-2000 CH GB i. GB_T OF-300 CH ii. GB_T OF-500 CH iii. GB_T OF-2000 CH Fiber network limits updated. Option to test Network Limits only on fiber. Network limits selection based on selected cable type / adapter. Modal bandwidth displayed based on fiber type. Improved copper custom limit template. Wiremap information localized. Set reference Image and instruction set updated for M12. Set reference image and instruction set updated for Coax Local >< Remote switch in copper. Resistance limit in Autotest detailed results. Page 3 of 6
4 Popup message if resistance delta is more than 1.5Ohms during copper set reference. Added End User License Agreement (EULA). Improved Talkset audio quality. New audio files. Improved accuracy on length measurement. Ability to use up and down arrow keys to scroll through LBT list. Labelling Improvements Improved battery performance Option to delete all test results without deleting site(s) Device now displays available storage instead of used storage Improved user interface for fiber limit setup Page 4 of 6
5 2 New or enhanced features: PC Software Improved firmware copying time to USB (around 40 seconds). Grey out conversion for fibre results. Alert user if USB drive is NTFS formatted. Import FLW files. Softing Logo in summary PDF. Margin values for network limits in detailed PDF report. Editable fields for site properties in PC software. New installation directory for export. Updated skins in install shield. Handling INFO only results If overall result for any of the measurement parameters (IL, RL, ACRF...) is "INFO" then the Worst Margin is displayed / values are always displayed in black even if they are negative. End User License Agreement (export / J Reporter). New sample project file. Improved text layout in PDF reports Improved PDF reports for OTDR tests Page 5 of 6
6 3 Known Issues First Autotest may fail when switching from Crossover to Twisted Pair or vice versa. For Fiber, if the user chooses a wrong cable type (different from the Adapter), no warning message will be displayed to the user. The network limits list will be empty, since network limits are displayed based on adapter and cable type. Tier 1 testing will also ignore the wrongly selected cable and will use the default value during AutoTest. a. Ex : MMEF adapter plugged in, OS1 Cable selected. If after upgrading your software to Version 7.3, you see an error message ERROR_NO_LIMIT_DATA_FILE, please go to Test Settings > Limits and select a new limit. This error is displayed because the TIA - Cat 8 Draft Channel and TIA - Cat 8 Draft Permanent Link have been renamed. Un-installation of export version 7.2 is required before installing version 7.3 export because of change in default installation directory. Re-Certification for application standards is not allowed. From Version 7.3 on, the PC software will not be supported for Windows XP OS. This is in line with the Microsoft Product Life Cycle. Please click on the link below for details Page 6 of 6
North America & Canada Softing Inc. Knoxville, Tennessee Tel.: Europe/Middle East/Africa
English North America & Canada Softing Inc. Knoxville, Tennessee Tel.: +1.865.251.5252 E-Mail: sales@softing.us Singapore Softing Singapore Pte. Ltd. Singapur Tel.: +65-6569-6019 E-Mail: asia-sales.itnetworks@softing.com
More informationSeries. WireXpert Key Features. Easy to use and Ruggedized design. Fast and simple for highest productivity
500 is an affordable and upgradable cable certification tester that can grow with your cable certification needs. Invest today only in options that are really needed and upgrade the device later when necessary.
More informationexport PC Software for WireXpert User Manual
export PC Software for WireXpert User Manual User Manual export PC Software, v7.2 WireXpert4500_eXport_IT_EN_U_201607_203 Copyrights 2016 Softing Singapore Pte Ltd http://itnetworks.softing.com Disclaimer
More informationComplimentary Reference Material
Complimentary Reference Material This PDF has been made available as a complimentary service for you to assist in evaluating this model for your testing requirements. TMG offers a wide range of test equipment
More informationWire pert. 1st CAT8 Cable Certifier. Ethernet CABLE CERTIFIER
Wire pert 1st CAT8 Cable Certifier The WireXpert is the first Ethernet cable certifier with capability to certify the highest performance cabling systems in enterprise networks and data centers. Cable
More informationPsiber Data WireXpert P R O F E S S I O N A L N E T W O R K T E S T I N G & P R O T O C O L A N A L Y S I S
Psiber Data WireXpert Agenda Psiber Data WireXpert Introduction Company Presentation Why Cable Certification? Universal Structured Cabling or The Network Standards The WireXpert Page 2 Psiber Data Company
More informationUser Manual Fiber Certification Testing
User Manual Fiber Certification Testing User Manual Fiber Certification, WireXpert v7.1.0, build #276 WireXpert4500_Fiber_IT_EN_U_201511_102S Copyrights 2015 Softing Inc. http://itnetworks.softing.com/
More informationPsiber ReportXpert. User s Manual
Psiber ReportXpert User s Manual CONTENTS Table of Contents CONTENTS 2 Chapter 1 4 Installation 4 Installation and Setup 4 Installing PDF Writer 4 Upgrade 4 Chapter 2 6 Project Management 6 Creating a
More informationLanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance
LanTEK III FiberTEK III Certifier for Copper and Fibre Cabling Proof of Performance LanTEK III FiberTEK III The LanTEK III is an easy to use cable certifier that meets existing TIA and ISO/IEC performance
More informationWire pert. Cable Certifier. 1st CAT. e C. Cable Tester of Choice
4500 Cable Certifier r tifie r e C e l b a C 8 1st CAT ation z i m i t p o w o fl k Now with wor The WireXpert is the first cable certifier with capability to certify the highest performance cabling systems
More informationLanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance
LanTEK III FiberTEK III Certifier for Copper and Fibre Cabling Proof of Performance LanTEK III FiberTEK III The LanTEK III is an easy to use cable certifier that meets existing TIA and ISO/IEC performance
More informationPRODUCT CATALOG. Certification, qualification, verification & troubleshooting of network infrastructure from copper up to 2,500MHz to fiber.
PRODUCT CATALOG Certification, qualification, verification & troubleshooting of network infrastructure from copper up to 2,500MHz to fiber. CONTENT FOREWORD Softing IT Networks is a manufacturer of measurement
More informationAdvanced Test Equipment Rentals ATEC (2832) OMNIScanner TM. featuring OMNIFiber TM
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMNIScanner TM featuring OMNIFiber TM the future of network testing OMNIScanner2 TM OMNIScanner LT TM OMNIFiber TM User
More informationDeviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved.
TC500 Ethernet Cabling Certifier Operation Manual Version 1.13 Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved. Warranty This instrument is guaranteed for a period of 2 years
More informationDATWYLER SYSTEM WARRANTY
DATWYLER SYSTEM WARRANTY Copper Cabling System Appendix A1 Systems Covered by the Warranty Juli 2014 Appendix A1_Systems Covered by Warranty Cu_July_2014_V01_EN.docx Page 1/9 Contents 1. Systems covered
More informationThe module for the highest standards, guarantees the best performance in the 10 Gigabit Ethernet cabling.
This is my title your first subtitle saecond subtitle Product information Connection Module Cat. 6A, 1x/s, 10x R509504 966733885 10 Stk. The module for the highest standards, guarantees the best performance
More informationUser Manual Copper Certification Testing
User Manual Copper Certification Testing User Manual Copper Certification, WireXpert v7.2, build #459 WireXpert4500_Copper_IT_EN_U_201607_104 Copyrights 2016 Softing Singapore Pte Ltd http://itnetworks.softing.com
More informationCopper USER MANUAL.
Copper USER MANUAL http://itnetworks.softing.com ENGLISH TABLE OF CONTENTS 1 Introduction... 4 1.1 About product... 4 1.2 Safety precautions... 4 1.3 Intended use... 5 1.4 About this document... 5 1.5
More informationDatasheet: DSX CableAnalyzer Series
Datasheet: DSX CableAnalyzer Series Datasheet: DSX CableAnalyzer Series The DSX CableAnalyzer Series is the copper certification solution of the Versiv cabling certification product family. The DSX Series
More informationPsiber Data. WireXpert. User Manual
Psiber Data WireXpert User Manual User Guide WireXpert v6.2.6 Rev.0 Last updated on 01-Dec-2014 Copyrights 2014 Psiber Data Pte Ltd www.psiberdata.com WX Series, (WX4500, WX500) www.psiberdata.com 2 Notices
More informationEthernet Cable Testing, Certifying & Diagnostics Jim Ralston Director of Sales
Softing Industrial Automation Data Exchange & Network Diagnostic Solutions Ethernet Cable Testing, Certifying & Diagnostics Jim Ralston Director of Sales Topics Softing Introduction Industrial Network
More informationFiber USER MANUAL.
Fiber USER MANUAL http://itnetworks.softing.com ENGLISH TABLE OF CONTENTS 1 Introduction... 4 1.1 About product... 4 1.2 Safety precautions... 4 1.3 Intended use... 5 1.4 About this document... 5 1.5 Before
More informationDatasheet: CableIQ Qualification Tester - The network tech s vision into cabling bandwidth.
Datasheet: CableIQ Qualification Tester - The network tech s vision into cabling bandwidth. CableIQ, the first cabling bandwidth tester for network technicians As an IT professional, you have a tough balancing
More informationOpen System Architecture Selecting the Right Cable and Connectivity for Your Application
Open System Architecture Selecting the Right Cable and Connectivity for Your Application Kenneth Cornelison Industry Consultant Wire and Cable Technology Engineering Resources Key Discussion Points TIA
More informationThe Impact of Internet of Things on Cable Certification
The Impact of Internet of Things on Cable Certification Softing IT Networks ---Philippe PATINOTE --- Agenda Short introduction Softing IT Networks Brief review on traditional office cabling configurations
More informationStructured Cabling Technology and Market Assessment
The Structured Cabling Market Bishop & Associates Inc. has released the new report Structured Cabling Technology and Market Assessment. This report contains in depth analysis of the market for structured
More informationNew standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks
New standards that have led to higher speeds and new cable categories Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks Three Realities of Networking #1 - Networks Never Go Slower Plan for higher
More informationField-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.
FM45 Connector Cat. 6 A IP20, 4P, TIA 568-A/B, 10x R815651 966704105 10 Stk. 090.7437 / ähnliche Abbildung Instruction manual Field-terminated connector with housing. Color housing: gray (RAL 7042). Color
More informationSCT2000 and SCT1500 Structured Cable Testers
SCT2000 and SCT1500 Structured Cable Testers USER MANUAL ENGLISH 1 SAFETY WARNINGS Read First: Safety and Operational Information The international symbols used on the instrument or in this manual are
More informationLinkRunner AT Network Auto-Tester Evaluation Guide
LinkRunner AT Network Auto-Tester Evaluation Guide Outline 1. Getting Started 2. Nearest Switch 3. Enable TruePower PoE Loading 4. Flash Switch Port 5. Enable IPv6 6. AutoTest 7. Add AutoTest Targets 8.
More informationField-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4
Field-testing procedure of LANmark-6 10G Cabling System Technical Paper Nexans Cabling Solutions June 2007 - Revision 1.4 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent
More informationLANmark-6 10G LANmark-6 A
Field-testing procedure of LANmark-6 10G LANmark-6 A Cabling System Technical Paper Nexans Cabling Solutions March 2006 - Revision 1.1 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction
More informationHOW DO I KNOW IF THE CABLING FIRM I AM TALKING WITH IS REALLY QUALIFIED? Wire is Wire Q & A. Cabling is an Investment. Ask the Right Questions
Wire is Wire Anybody can install it, right? Just about anyone can run wire but a proper installation by a trained installer allows your technology investment to work at its full potential! Cabling is an
More informationQualified Partner Programme QPP. Warranty Felice Guarna
Qualified Partner Programme QPP Warranty Felice Guarna Overview Why a warranty? R&M warranties at a glance Prerequisites Product warranty System warranty Application warranty Procedure Summary Warranty
More informationAppendix 1 to the R&Mfreenet Warranty Program
Appendix 1 to the R&Mfreenet Warranty Program 1 R&M Certification Process The R&Mfreenet certification process is three pillars: a) Adherence to applicable standards, both for products and installations;
More informationThe Impact of Internet of Things (IoT) on Cable Certification
The Impact of Internet of Things (IoT) on Cable Certification Simon Harrison General Manager Softing Singapore Pte Ltd November 2017 Agenda Review of traditional structured cabling configurations Special
More informationCable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment F Cable Certification
General Testing Criteria (Applies to all cable certification testing) 1. RCIT reserves the right to be present during any or all cable testing procedures. The Contractor shall obtain authorization from
More information"IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI TRASMISSIVI FINO A 250 MHZ"
"IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI TRASMISSIVI FINO A 250 MHZ" Gli standard per la categoria 6 e i nuovi strumenti di misura maurizio.malinconi@flukenetworks.com
More informationCertification for 10G copper cabling
Certification for 10G copper cabling Presented by Eric Lie, Sales Manager 1 Introduction This presentation is intended to provide an overview of the 10GBASE-T requirements for cabling The applicable standards
More informationEnterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India
Enterprise Network Test Strategies for Network Availability and Performance A Sitaramaiah Director Fluke Networks India 1 Why is Enterprise Network Testing becoming increasingly important? IT is increasingly
More informationOptical Certifier I. Tier-1 Fibre Certifier for Multimode and Single-mode Fibre Cabling. Proof of Performance
Optical Certifier I Tier-1 Fibre Certifier for Multimode and Single-mode Fibre Cabling Proof of Performance Optical Certifier I Tier-1 Fibre Certifier for Multimode and Single-mode fibre cabling The Optical
More informationAdvanced Test Equipment Rentals ATEC (2832) OMNIScanner 2 OMNIFiber
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMNIScanner 2 OMNIFiber OMNISCANNER2 TM OMNIFIBER TM User Guide ENGLISH A Guide to using the OMNISCANNER to install,
More informationTesting Considerations for Beyond 10Gigabit Ethernet. Erin Hallett
Testing Considerations for Beyond 10Gigabit Ethernet Erin Hallett JDSU Agenda Intro Need for Speed Growth of IP traffic Fiber vs. Copper Fiber Tightening requirements Testing considerations and practices
More informationLanTEK II Series Manual
LanTEK II Series Manual 0 LanTEK II Cable Certifier Instruction Manual This instruction manual contains information proprietary to IDEAL INDUSTRIES, INC. The information in this document is not to be used
More informationWIREXPERT FIBER LOSS TEST KIT TECHNICAL REFERENCE MANUAL. WireXpert Fiber Loss Test Kit Technical Reference Manual
WireXpert Fiber Loss Test Kit Technical Reference Manual i Table of Contents Introduction... 1 Package Contents... 1 Single-mode Certification Kit... 1 Multi-mode Certification Kit... 1 Features and Benefits...
More informationScopeData Pro User s Guide
ScopeData Pro User s Guide Part Number N2605A-071 Version 3.0 Print Date: July 2002 Copyright 1999, 2000, 2001, 2002 Agilent Technologies. All rights reserved. Trademarks FrameScope and WireScope are registered
More informationProvided by
Provided by www.aaatesters.com Datasheet: DSX-5000 CableAnalyzer The DSX-5000 CableAnalyzer is the copper certification solution and is part of the Versiv cabling certification product family. The Versiv
More informationIndustry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"
Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print" Gautier Humbert, RCDD Standards Coordinator Legrand Digital Infrastructures Gautier Humbert, RCDD BICSI District Chair Mainland
More informationHistory of Standards
History of Standards From 10Mbps to 100Gbps Ethernet 12 th May 2014 Gautier Humbert, RCDD Business Development Manager Legrand East and Central Europe Agenda 1- Current standards and their structures
More informationOptoFidelity VR Multimeter User Manual Version 2017Q1.0
OptoFidelity VR Multimeter User Manual Version 2017Q1.0 OptoFidelity Oy sales@optofidelity.com www.optofidelity.com Contents OptoFidelity VR Multimeter... 1 User Manual... 1 1 General information on OptoFidelity
More informationCommon Mistakes Made in Certification Specifications and Testing. Jim Davis Regional Marketing Engineer Fluke Networks
Common Mistakes Made in Certification Specifications and Testing Jim Davis Regional Marketing Engineer Fluke Networks Common Mistake #1 Failing to specify a Permanent Link test #1 Permanent Link or Channel?
More informationCabling for Data Centres. Andrew Sedman RCDD/NTS Technical Director MEA Reichle & DeMassari
Cabling for Data Centres Andrew Sedman RCDD/NTS Technical Director MEA Reichle & DeMassari Data Center Definition is a facility used to house computer systems and associated components, such as telecommunications
More informationCeres M7000 Time & Attendance System Installation & Operation Instructions:
Page1 Ceres M7000 Time & Attendance System Installation & Operation Instructions: Table of Contents I. Minimum requirements:... 2 II. Ceres M7000e Installation (Steps):... 2 III. M7000 ibutton Time Recorder
More informationAgilent Technologies N2600A WireScope 350. User s Manual. Agilent Technologies. Version 3.0
Agilent Technologies N2600A WireScope 350 User s Manual Version 3.0 Agilent Technologies 1RWLFHV Notices No part of this manual may be reproduced in any form or by any means (including electronic storage
More informationDatasheet: DSX-5000 CableAnalyzer
Datasheet: DSX-5000 CableAnalyzer The DSX-5000 CableAnalyzer is the copper certification solution and is part of the Versiv cabling certification product family. The Versiv line also includes fiber OLTS
More informationPhysical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks
Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks Agenda New ISO/IEC 11801 Standard New Fibre standards and encoding methods Higher speeds,
More informationTesting and Measurement Technology. Handbook of Cable Testing. Fault Analysis Documentation and Reporting. h ps://itnetworks.softing.
Testing and Measurement Technology Handbook of Cable Testing h ps://itnetworks.softing.com Fault Analysis Documentation and Reporting Editorial On the way to new frontiers High-quality copper wiring in
More informationDatasheet: DSX CableAnalyzer Series
Datasheet: DSX CableAnalyzer Series The DSX CableAnalyzer Series is the copper certification solution of the Versiv cabling certification product family. The DSX Series includes the DSX-8000, which can
More informationGet ready to overachieve.
Datasheet: DSX-5000 CableAnalyzer The DSX-5000 CableAnalyzer is the copper certification solution and is part of the Versiv cabling certification product family. The Versiv line also includes fiber OLTS
More informationCOPYRIGHT NOTICE IDEAL INDUSTRIES LTD All rights reserved Publication ref: Issue 1-11/2015 (Applies to software revision 3.
LanTEK III COPYRIGHT NOTICE The information contained in this document is the property of IDEAL INDUSTRIES Ltd. and is supplied without liability for errors and omissions. No part of this document may
More informationCIFER Standards Converter
CIFER Standards Converter Update Instructions Pro-Bel Ltd Issue: 1.0 Date: April 07 Pro-Bel Ltd Hartman House Danehill Lower Earley Reading Berks, RG6 4PB ENGLAND Web: www.pro-bel.com HU-CIFER-UPDATE 1
More informationHANDBOOK OF CABLE TESTING
Testing and Measurement Technology Fault Analysis Documentation and Reporting HANDBOOK OF CABLE TESTING Wire pert Cable Certifier WX4500 Best-in-Class Certifier for today and tomorrow. CAT 8 Ready! CAT8
More informationWire pert. 1st CAT8 Cable Ceriier CABLE CERTIFIER
Wire pert 1st CAT8 Cable Ceriier The WireXpert is the irst cable ceriier with capability to cerify the highest performance cabling systems in enterprise networks and data centers. Cable installers make
More informationYour complete guide to building an NMEA 2000 network. Issue 1.1
Your complete guide to building an NMEA 2000 network Issue 1.1 Contents Who are the NMEA and What is NMEA 2000? 3 3 Who are the NMEA? 3 What is NMEA 2000? 3 The Network That CAN 3 DeviceNet 3 Certification
More informationDatasheet: DSX CableAnalyzer Series
Datasheet: DSX CableAnalyzer Series The DSX CableAnalyzer Series is the copper certification solution of the Versiv cabling certification product family. The DSX Series includes the DSX-8000, which can
More informationDatasheet: DSX CableAnalyzer Series
Datasheet: DSX CableAnalyzer Series Datasheet: DSX CableAnalyzer Series The DSX CableAnalyzer Series is the copper certification solution of the Versiv cabling certification product family. The DSX Series
More informationStandards Update. by Paul Kish NORDX/CDT
Standards Update by Paul Kish NORDX/CDT Standards overview Category 5e cabling new transmission parameters patch cord return loss Category 6 cabling cable choices backwards compatibility Summary Outline
More informationValidator TM NETWORK/CABLING CERTIFIER OPERATING INSTRUCTIONS. Validator NT950
Validator TM NETWORK/CABLING CERTIFIER OPERATING INSTRUCTIONS Validator NT950 CONTEXT SENSITIVE KEYPAD VALIDATOR TM Test Results 50% Cable001 2004 Oct11 Test Time: 10/11/2004 10:53 A.M Test Results Expected
More informationHands-On Fiber Optics & Fiber Management Systems
Hands-On Course Description As a transport medium, copper has significant bandwidth and distance limitations. Fortunately, an alternative exists mankind has yet to determine the bandwidth or distance limitations
More informationQuick Installation Guide
LPH1004A Hardened Ethernet PoE Switch, (4) 10/100/1000 Mbps, (1) GE SFP Quick Installation Guide LPH1000 Series Switches operate in harsh environments. Two power inputs connect simultaneously to live DC
More informationAn Introduction to Transmission Testing in the LAN Environment Copyright 2014, IDEAL Networks
An Introduction to Transmission Testing in the LAN Environment Copyright 2014, IDEAL Networks Testing the performance of network cabling has evolved, providing installers with better tools to prove an
More informationData sheet C6 A modul 90 jack
Illustrations Dimensional drawing Cut-out Page 1/7 See enlarged drawings at the end of document Product specification modular Cat.6 A termination unit RJ45 mounting version: module, 90 cable feed solid,
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationAgilent N2640A WireScope Pro
Agilent N2640A WireScope Pro User s Guide Agilent Technologies Notices Agilent Technologies, Inc. 2002, 2008 No part of this manual may be reproduced in any form or by any means (including electronic storage
More informationDTX CableAnalyzerTM Accessories Guide
NETWORKSUPERVISION DTX CableAnalyzerTM Accessories Guide See how Fluke Networks options and accessories can easily enhance your investment. Smart Remotes Contents Smart Remotes................. 2 DTX 10
More informationIMPORTANT NOTE for. Choose the zip file v and unzip it in USB. Do not rename the UPG folder. Follow
IMPORTANT NOTE for (HTB3280G/12 HTB3520/40/55/94/98 HTB3520G/12/51 HTB3550/40/98 HTB3550G/12 HTB3580/40/79/98 HTB3580G/12/51 HTB4520G/51 HTB4580G/51 HTB5260G/12 HTB5520/55/94/98 HTB5520G/12 HTB5550/98
More informationPANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY
PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents
More informationSignalTEK II. idealindustries.com
Save money by using a single multifunction device in place of separate copper, fiber and Power over Ethernet (PoE) testers Increase efficiency through simplifying and accelerating cable installation including
More informationTest Report Number: G CRT-039g
3933 US Route 11 Cortland, New York 145 Telephone: +1 () 345-3851 Facsimile: +1 (7) 758-6637 www.intertek.com Project Number: G28364 Certificate of Conformance Number: 324722CRT-1f Date Issued: 5/29/15
More informationNetwork Connectivity. Copper LAN cables. Product catalogue 2010
Product catalogue 2010 . Part of a total solution. The Schneider Electric copper LAN cables are an important part of our total Network Connectivity solution that also includes panels, cabinets, connectors
More informationGXLink MultiChannel Wave Inserter Model SP-631
800173-0A Digital High Speed GXLink MultiChannel Wave Inserter Model SP-631 User Manual Copyright 2009 It is prohibited to copy, reproduce or distribute this information in whole or in part without the
More informationPATCH CABLE 132 WIR SORGEN FÜR VERBINDUNG
opper Connection T PATCH CABLE In the patch cable section we offer you a broad product spectrum of assembled cable variants. The availability of our products warrants you a fast supply of our cable. Besides
More informationProduct information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m
Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m R509858 101376015 10 pcs Cable identification: S/FTP Outer jacket: LSFRZH Conductor diameter copper strand: AWG 26/7
More informationEMIT SIM Software Installation and User Manual
TECHNICAL BULLETIN TB-6579 EMIT SIM Software Installation and User Manual Made in the United States of America Description EMIT SIM (Smart Ionization and Monitoring) is designed to monitor and record the
More informationMigratable cabling in computer centres for all data rates from Mbit/s to 100Gbit/s (DClink)
Introduction Computer centres must be reliable and available around the clock even during conversion work. Data rates are increasing constantly, and the FO cabling which only recently supported all applications
More information1157 Phoenixville Pike, Suite 201 West Chester, PA Voice: Fax:
Firmware Updates Firmware is the software code embedded in your Aviom device s permanent memory that makes it work. The A360 Personal Mixer s firmware can be updated in the field to add new features and
More informationCERTIFICATION PLUS SM
CERTIFICATION PLUS SM SYSTEM WARRANTY PROGRAM Panduit Warranty Guide PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction & Installation
More information40 Gigabit over copper - Thorsten Punke Marketing Manager ANZ TE Connectivity
40 Gigabit over copper - 40GBase-T Thorsten Punke Marketing Manager ANZ TE Connectivity IEEE 802.3 Ethernet Update 40GBase-T The history The technical truth The technical history More speed equals to more
More informationOBSOLETE. CanWorks itrax Two-Channel Control Unit Installation. Instruction Sheet P/N A
Instruction Sheet P/N 1047805A CanWorks itrax Two-Channel Installation WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other
More informationNMCnet User Manual. Table of Contents
NMCnet Table of Contents NMCnet Basic Requirements... 3 nstallation NMC Net Communication Program... 4 Network Setup... 5 Local Network... 5 Modem Network... 7 Modem Communication Setting... 7 Demo Network...
More information9/27/04 cci Cablecom Inc. 1
cci Cablecom Inc. 1 CCI Cablecom Inc. is a privately held, women owned corporation headquartered in Aurora, CO. We manufacture a variety of voice and datacom products. Cable applications Include: Local
More informationLAN Standards, News & Trends Update 2017 June 15, 2017
LAN Standards, News & Trends Update 2017 June 15, 2017 Greg Olson Jtech Systems, Inc Infrastructure Specialist Greg@jtechreps.com 425-437-1962 Our Objectives Review new & ongoing applications work in IEEE
More informationProgrammable LED Driver Configuration Tool User Manual
Programmable LED Driver Configuration Tool User Manual Please send feedback or ask support questions by emailing software@erp-power.com ERP Power, LLC 893 Patriot Drive #E Moorpark, CA 93021 +1-805-517-1300
More informationCopper Cabling Standards
Copper Cabling Standards White paper White Paper Copper Cabling Standards v2.0 EN 1 Introduction Standard specifications are the foundation upon which most cabling and networking projects are built. Professionals
More informationWireScope 155 SCOPE. Agilent Wirescope 155 Specs Provided by The Performance Leader in Hand-Held Network Tools
Agilent Wirescope 155 Specs Provided by www.aaatesters.com WireScope 155 Tests installed cabling for compliance with TIA 568A Category 5 and ISO 11801 Class D specifications. Fully implements TIA TSB-67
More informationConnecting and Routing the Cables and Wires
This chapter explains how to install the NCS 2002 shelf. The sections are: NTP-L36 Attaching Wires to Timing, LAN, and Craft Pin Connections in NCS 2002, on page 1 NTP-L36 Attaching Wires to Timing, LAN,
More informationChapter 3 Certifying Twisted Pair Cabling
Chapter 3 Certifying Twisted Pair Cabling Setting the Reference The reference procedure sets a baseline for insertion loss, ELFEXT, and dc resistance measurements. Run the tester s reference procedure
More informationSpectrometer Visible Light Spectrometer V4.4
Visible Light Spectrometer V4.4 Table of Contents Package Contents...3 Trademarks...4 Manual Driver and Application installation...5 Manual Application Installation...6 First Start of the Application...8
More informationNGBASE-T Cabling Requirements
NGBASE-T Cabling Requirements Dr. T. C. Tan, DMTS, CommScope Labs B.Sc (Eng), DIC, PhD, CEng, FIET White paper www.commscope.com Contents Contents Contents 2 1.0 Introduction 3 2.0 IEEE 802.3 NGBASE-T
More informationFOCIS Flex Inspection
Test & Inspection FOCIS Flex Inspection Fiber Optic Connector Inspection Solution User s Guide www.flglobal.com, +1 (800) 321-5298 or +1 (603) 528-7780 Table of Contents Safety Information.... 3 FOCIS
More information