1 ENA Multiport Solution Setup Procedure of MWA Software for SP9T (10-port) Switch Step 1. Define a test plan Step 2. Create a setup file Step 3. Perform measurement Rev

2 Step 1. Define a Test Plan DUT (SP9T Switch) 10-port DUT. SP9T (Single-pole, 9-throw, one-input and 9-outputs) switch. S-parameter measurement on all paths out of the 10-port DUT. The connected output port is determined by 4-bit logic control signals to Vc1 to Vc4 input. Vdd 2 3 UMTS1 (850 MHz) UMTS2 (1900 MHz) Truth Table of Control Bits (Vc1 to Vc4) 1 ANT UMTS3 (2100 MHz) GSM Rx1 (850 MHz) GSM Rx2 (900 MHz) GSM Rx3 (1800 MHz) GSM Rx4 (1900 MHz) GSM Tx1 (850/900 MHz) GSM Tx2 (1800/1900 MHz) Vc1 to Vc4

3 Step 1. Define a Test Plan Measurement Parameters - Example

4 Step 1. Define a Test Plan Measurement with ENA Multiport Solution Single connection with the 4-port ENA & E5092A Configurable Multiport Test Set. DC control voltage can be applied from the E5092A, enabling synchronous S-parameter measurement. Power supply of the DUT (Vdd) can be applied from internal DC source in E5092A. Measurement Wizard Assistant (MWA) software offers simplified measurement procedure. Control line connectors For DC control functions 4-port ENA E5092A Vdd UMTS1 UMTS2 ANT Switch Control Vc1 Vc2Vc3 Vc4 UMTS3 GSM Rx1 GSM Rx2 GSM Rx3 GSM Rx4 GSM Tx1 GSM Tx2

5 Step 1. Define a Test Plan DC Control Function of E5092A Internal DC source of Group A is used for control voltage (Vc1 to Vc4) of DUT. Internal DC source of Group B is used for bias voltage (Vdd) of DUT. 0 ~ +5 V 10 mv (res.) DC Source (Group A) 150 ma (max) Max Current Output Voltage DC Source Output Output Impedance 5 ohm (max) GND 0 to +5 V Positive Input (High) -5 to 0 V Negative Input (Low) Control Line 1 (Group A) 50 ma (max) Max Current : Impedance 10 ohm (max) : Control Line 1 (Group A) Control Line 2 (Group A) Control Line 3 (Group A) Control Line 4 (Group A) : Control Line 8 (Group A) 4-bits used for control voltage (Vc1 to Vc4) DC Source (Group B) DC Source Output Same as Group A GND Positive Input (High) Control Line 2 (Group B) Same as Group A (Output bit: 4-bits) Negative Input (Low) Control Line 1 (Group B) Control Line 2 (Group B) Control Line 3 (Group B) Control Line 4 (Group B) 1-bit used for bias voltage (Vdd) Block diagram of Control line of the E5092A Note: For more details on DC control function of the E5092A, see FAQ Is it possible to supply a DC control voltage to a multiport DUT with the E5092A.

6 Step 2. Create a Setup File 2-1. Launch MWA Front-End Application Run the MWA Front-end application ( mwa_xxxx.xls ). 1. Copy the MWA Front-End application Copy mwa_xxxx.xls in your PC. Launch by double-clicking. 2. Enable Excel Macro Click Options.. on Security Warning tab. Select either Enable this contents or Trust all documents from this publisher. Note: The latest revision of the MWA can be downloaded at: Note: Microsoft Excel 2007 is required to operate the Front-end application of the MWA with rev.1.11.

7 Step 2. Create a Setup File 2-2. Multiport Test Set setup Select the appropriate instrument and measurement configuration of the multiport test set based on the test plan. 1. Select [E5092A X10-Port] of 10-port full crossbar configuration with E5092A. 2. Measurement connectivity matrix is automatically updated. 3. Rename test set port (optional) Multiport Test Set Sheet of the MWA Front-end Application Port number and cable connection of the 10-port full crossbar configuration with the E5092A

8 Step 2. Create a Setup File 2-3. DUT setup Enter information of the DUT, port connection, and parameters of Fixture Simulator functions on the ENA. 1. Assign port name of DUT 2. Select [Single] for the DUT ports 3. Assign port of test set connected to DUT Vdd Switch Control UMTS1 UMTS2 UMTS3 GSM Rx1 GSM Rx2 GSM Rx3 GSM Rx4 GSM Tx1 GSM Tx2 DUT sheet of the MWA Front-end Application Vc1 Vc2Vc3 Vc4

9 Step 2. Create a Setup File 2-4. Mode setup Define the operation mode of DUT. Select control bit (High or Low) and corresponding DC voltage of internal DC sources in the E5092A for operation mode of DUT. 1. Enter name of DUT s operation mode 3. Setup High/Low bits for control line 2. Turn on this mode by double-clicking the cell Mode sheet of the MWA Front-end Application 4. Setup DC voltage of internal DC sources in the E5092A Note: For more details on DC control function of the E5092A, see FAQ Is it possible to supply a DC control voltage to a multiport DUT with the E5092A.

10 Step 2. Create a Setup File 2-5. GPIB setup (optional) Set GPIB commands for controlling other instruments connected to the ENA via USB/GPIB interface. Note: No need to setup in this sheet, if no peripherals are used for measurement with the MWA. GPIB sheet of the MWA Front-end Application

11 Step 2. Create a Setup File 2-6. Spec Sheet setup Input all the measurement parameters and specified values for the limit test by the Back-end application. 1. Set measurement path 2. Select format type 3. Set stimulus parameters 4. Define limit values (=specification of DUT) : Spec Sheet spreadsheet of the MWA Front-end Application

12 Step 2. Create a Setup File 2-6. Spec Sheet setup Input all the measurement parameters and specified values for the limit test by the Back-end application. To increase measurement paths in the mode: A) double-click in mode cell, or B) right-click in cells of stimulus parameters to show dialog box. A. Double-click in mode cell B1. Right-click in cells of stimulus parameters B2. Select [Insert Record] in a dialog box Spec Sheet spreadsheet of the MWA Front-end Application

13 Step 2. Create a Setup File 2-7. Output setup Generate a spec sheet (*.mwa) including all setup parameters for measurement. 1. Identify required number of channels and traces on the ENA. (Max 45 channels and 7 traces) Note: The MWA automatically allocates in channels or traces of the ENA, and the list of allocation is updated in this sheet. 2. Set the max number of channels and traces available on the ENA. (ex. 72 Ch, 9 Tr, 401 Points ) 3. Generate and save a spec sheet (*.mwa) : 1 1 Output sheet of the MWA Front-end Application

14 Step 3. Perform Measurement 3-1. Instrument setup Setup the ENA & E5092A Configurable Multiport Test Set. 1. Connect ENA & E5092A Connect adaptors on the ENA Connect the ENA & E5092A with semi-rigid cables 2. Setup 10-port full crossbar configuration with the E5092A Connect semi-rigid cables on the E5092A 10-port full crossbar configuration of the ENA & E5092A Note: For more details on connection between the E5071C & E5092A, see FAQ How can I get the accessories (cables and adaptors) for measurement setup of the ENA & the E5092A?.

15 Step 3. Perform Measurement 3-2. Launch the Back-End Application Run the MWA Back-end application after the channel/trace setup of the ENA 1. Setup Channel/Trace on the ENA [System] > Service Menu > Channel/Trace Setup > 72 Ch / 9 Tr 401 Points Select the appropriate channel/trace setup based on the maximum required channels or traces (See Output sheet of the Front-end application.) 2. Copy the MWA Back-End application Copy mwa_xxxx.vba to the directory of ENA. (*1) Copy a spec sheet (*.mwa) generated by Front-end application. 3. Select and launch the MWA Back-End application [Macro Setup] > Load Project > Select mwa_xxxx.vba [Macro Run] *1: When saved under D VBA of the ENA, the Back-end application can be directly launched by [Macro Setup] > Load & Run > mwa_xxxx

16 Step 3. Perform Measurement 3-3. Import a setup file Import a setup file (spec sheet, *.mwa) generated by the Front-end application. 1. Select [Add Spec Sheet Group] 2. Create new group file ( *.ssg ) 3. Add spec sheet ( *.mwa ) 4. Setup parameters of recalled spec sheets Main window of the MWA Back-end Application 5. List of recalled spec sheet is updated. Spec sheet dialog box of the MWA Back-end Application

17 Step 3. Perform Measurement 3-4. Perform calibration Perform necessary calibration with the calibration wizard of the MWA. 1. Select [Cal Wizard] 2. Select [4 Port ECal] Main window of the MWA Back-end Application 3. Select [NEXT] to continue 4. Repeat measurement until all necessary calibrations are performed. Calibration wizard dialog box of the MWA Back-end Application

18 Step 3. Perform Measurement 3-5. Confirm connection Confirm correct connection between the DUT and the test set ports. 1. Select [Connection Information] 2. Connect test set ports and DUT Vdd Switch Control UMTS1 UMTS2 UMTS3 GSM Rx1 GSM Rx2 GSM Rx3 GSM Rx4 GSM Tx1 GSM Tx2 3. Select [Close] to go back to Main window Main window of the MWA Back-end Application Vc1 Vc2Vc3 Vc4 Connection Information dialog box of the MWA Back-end Application

19 Step 3. Perform Measurement 3-6. Start measurements Start measurement sequence. 1. Select [Measurement] Main window of the MWA Back-end Application Measurement window of the MWA Back-end Application

Keysight Technologies Measurement Wizard Assistant (MWA) Software for the ENA. Application Note

Keysight Technologies Measurement Wizard Assistant (MWA) Software for the ENA. Application Note Keysight Technologies Measurement Wizard Assistant (MWA) Software for the ENA Application Note Introduction In today s fast-paced testing environments, with increasing functionality supported in devices

More information

Keysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA

Keysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA Revision 1.01 Feb-24, 2017 Universal Serial Bus Type-C TM Specification Revision 1.1 Keysight Method of Implementation (MOI) for USB Type-C TM Cables Assemblies Compliance Tests Using Keysight For Type-C

More information

Agilent ENA RF Network Analyzer

Agilent ENA RF Network Analyzer Agilent ENA RF Network Analyzer Configuration Guide E5071C E5091A 9 khz to 4.5 GHz 100 khz to 4.5 GHz (with bias tees) 9 khz to 8.5 GHz 100 khz to 8.5 GHz (with bias tees) Multiport test set This configuration

More information

Keysight MOI for USB 2.0 Connectors & Cable Assemblies Compliance Tests

Keysight MOI for USB 2.0 Connectors & Cable Assemblies Compliance Tests Revision 1.10 October 18, 2016 Universal Serial Bus Specification Revision 2.0 Keysight Method of Implementation (MOI) for USB 2.0 Connectors and Cables Assemblies Compliance Tests Using Keysight E5071C

More information

Agilent. E5092A Configurable Multiport Test Set. Configuration Guide

Agilent. E5092A Configurable Multiport Test Set. Configuration Guide Agilent E5071C Network Analyzer 9 khz to 4.5 GHz 100 khz to 4.5 GHz (with bias tees) 9 khz to 8.5 GHz 100 khz to 8.5 GHz (with bias tees) 300 khz to 20 GHz (with bias tees) E5092A Configurable Multiport

More information

Keysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA

Keysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA Revision 1.00 Apr-14, 2016 Universal Serial Bus Type-C TM Specification Revision 1.1 Keysight Method of Implementation (MOI) for USB Type-C TM Cables Assemblies Compliance Tests Using Keysight For Type-C

More information

Agilent ENA-L RF Network Analyzers

Agilent ENA-L RF Network Analyzers Agilent ENA-L RF Network Analyzers Configuration Guide E5061A E5062A 300 khz to 1.5 GHz 300 khz to 3 GHz This configuration guide describes standard configurations, options, accessories and peripherals

More information

E5092A Configurable Multiport Test Set

E5092A Configurable Multiport Test Set Keysight Technologies E5080A Network Analyzer 9 khz to 4.5/6.5/9 GHz E5092A Configurable Multiport Test Set Configuration Guide 02 Keysight 5080A Network Analyzer & E5092A Configurable Multiport Test Set

More information

Agilent. E5071C Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Agilent. E5071C Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees) Agilent E5071C Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees) E5092A Configurable Multiport Test Set Configuration Guide This

More information

Keysight Technologies E5080A ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

Keysight Technologies E5080A ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set Keysight Technologies E5080A ENA Vector Network Analyzer 9 khz to 4.5/6.5/9 GHz E5092A Configurable Multiport Test Set Configuration Guide 02 Keysight E5080A ENA Vector Network Analyzer & E5092A Configurable

More information

Keysight Technologies E5071C Network Analyzer

Keysight Technologies E5071C Network Analyzer Keysight Technologies E5071C Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees) E5092A Configurable Multiport Test Set Configuration

More information

Keysight Technologies E5080A ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

Keysight Technologies E5080A ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set Keysight Technologies E5080A ENA Vector Network Analyzer 9 khz to 4.5/6.5/9 GHz E5092A Configurable Multiport Test Set Configuration Guide 02 Keysight E5080A ENA Vector Network Analyzer & E5092A Configurable

More information

How to use EquationEditor_Examples.txt with the Equation Editor function on the ENA Network Analyzer

How to use EquationEditor_Examples.txt with the Equation Editor function on the ENA Network Analyzer How to use EquationEditor_Examples.txt with the Equation Editor function on the ENA Network Analyzer Document revision: 01.00 Document history: 2008/11/25 First release This document explains how to use

More information

TTR500 Series Vector Network Analyzers Demonstration Guide

TTR500 Series Vector Network Analyzers Demonstration Guide xx ZZZ TTR500 Series Vector Network Analyzers Demonstration Guide *P071349301* 071-3493-01 xx ZZZ TTR500 Series Vector Network Analyzers Demonstration Guide Register now! Click the following link to protect

More information

Evaluation Board Quick Start

Evaluation Board Quick Start Publication: QS/PE0302-865A/1 CML Microcircuits COMMUNICATION SEMICONDUCTORS Evaluation Board Quick Start PE0302-865A 1 Introduction Thank you for your interest in the PE0302-865A Evaluation Board. This

More information

Quick-Start Guide To get ready to use Fixture offset Calculator: For each job (all done on Sheet1):

Quick-Start Guide To get ready to use Fixture offset Calculator: For each job (all done on Sheet1): Quick-Start Guide To get ready to use Fixture offset Calculator: 1) Set the security of Microsoft Excel to enable macros a. From the Tools Menu, select options. Then click the tab for Security and click

More information

Automotive Ethernet BroadR-Reach

Automotive Ethernet BroadR-Reach Automotive Ethernet BroadR-Reach Agilent PHY Compliance Solutions 1 Last update 2013/07/25 (YS) Agenda BroadR-Reach Overview Transmitter Testing Link Segment Testing 2 BroadR-Reach Applications 3 Connectivity

More information

MIPI D-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET

MIPI D-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET The InterOperability Laboratory MIPI D-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET Abstract: This document serves as the primary documentation for the MIPI D-PHY Reference Termination

More information

Keysight Technologies On-Wafer Testing of Opto-Electronic Components Using the Lightwave Component Analyzers. Application Note

Keysight Technologies On-Wafer Testing of Opto-Electronic Components Using the Lightwave Component Analyzers. Application Note Keysight Technologies On-Wafer Testing of Opto-Electronic Components Using the Lightwave Component Analyzers Application Note Introduction When measurements of optoelectronic components are performed on

More information

Advanced Test Equipment Rentals ATEC (2832) Manual Supplement. Agilent E5070B/E5071B ENA Series RF Network Analyzers

Advanced Test Equipment Rentals ATEC (2832) Manual Supplement. Agilent E5070B/E5071B ENA Series RF Network Analyzers Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Agilent E5070B/E5071B ENA Series RF Network Analyzers Manual Supplement Second Edition Agilent Part No. E5070-90045

More information

ENA Control Tool software

ENA Control Tool software ENA Control Tool software Notices The information contained in this document is subject to change without notice. This document contains proprietary information that is protected by copyright. All rights

More information

PCI Express Signal Quality Test Methodology

PCI Express Signal Quality Test Methodology PCI Express Signal Quality Test Methodology Users Guide LeCroy SDA 6000 October 2003 Revision 0.7 Document Number: XXXX DISCLAIMER OF WARRANTIES THIS SPECIFICATION IS PROVIDED AS IS AND WITH NO WARRANTIES

More information

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes N5395B Ethernet Electrical Conformance Test Fixture N5396A Gigabit Ethernet Jitter

More information

MAXSANTAFEEVSYS User Manual

MAXSANTAFEEVSYS User Manual MAXSANTAFEEVSYS User Manual Rev 0; 5/14 For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim Integrated s website at www.maximintegrated.com. Maxim

More information

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes N5395B Ethernet Electrical Conformance Test Fixture N5396A Gigabit Ethernet Jitter

More information

PXI Vector Network Analyzer

PXI Vector Network Analyzer CONFIGURATION GUIDE PXI Vector Network Analyzer M9370A 300 khz to 4 GHz M9371A 300 khz to 6.5 GHz M9372A 300 khz to 9 GHz M9373A 300 khz to 14 GHz M9374A 300 khz to 20 GHz M9375A 300 khz to 26.5 GHz Drive

More information

SP336E Evaluation Board Manual Rev 2.1

SP336E Evaluation Board Manual Rev 2.1 SP336E Evaluation Board Manual 11-23-10 Rev 2.1 Features Easy Evaluation of the SP336E Transceiver RS-232 and RS-485 Protocols Local or Remote Loop Back testing 10Mbps Differential Transmission Rates Test

More information

IntuiLink for Basic (Agilent E3600 series) DC Power Supplies

IntuiLink for Basic (Agilent E3600 series) DC Power Supplies IntuiLink for Basic (Agilent E3600 series) DC Power Supplies Agilent IntuiLink for Agilent E3600-Series DC power supplies offers the following capabilities: - Make a variety of measurements and insert

More information

Programmable DC Power Supplies XLN Series

Programmable DC Power Supplies XLN Series Data Sheet New Family of High Density System Power Supplies The B&K Precision XLN series are programmable, single-output DC power supplies, that provide clean power up to 1560 watts in a compact 1U rackmountable

More information

Termination Options for Any-Frequency Si51x XOs, VCXOs

Termination Options for Any-Frequency Si51x XOs, VCXOs Termination Options for Any-Frequency XOs, VCXOs 1. Introduction This application note provides termination recommendations for connecting output clock signals to the family of XO and VCXO ICs and is not

More information

Agilent E5072A ENA Series Network Analyzer

Agilent E5072A ENA Series Network Analyzer Agilent E5072A ENA Series Network Analyzer 30 khz to 4.5 /8.5 GHz Configuration Guide Ordering Guide The following steps will guide you through configuring your E5072A. 1-year return to Agilent service

More information

Keysight N5990A Type-C Extension. User Guide

Keysight N5990A Type-C Extension. User Guide Keysight N5990A Type-C Extension User Guide Notices Keysight Technologies 2017 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation

More information

High Speed Characterization Report. DVI-29-x-x-x-xx Mated With DVI Cable

High Speed Characterization Report. DVI-29-x-x-x-xx Mated With DVI Cable High Speed Characterization Report DVI-29-x-x-x-xx Mated With DVI Cable REVISION DATE: 07-18-2004 TABLE OF CONTENTS Introduction... 1 Product Description... 1 Overview... 2 Results Summary... 3 Time Domain

More information

Agilent PNA Series Microwave Network Analyzers

Agilent PNA Series Microwave Network Analyzers Agilent PNA Series Microwave Network Analyzers Configuration Guide PNA-L N5230A PNA-L N5230A PNA E8362B PNA E8363B PNA E8364B PNA E8361A PNA N5250A 300 khz to 6, 13.5, or 20 GHz 10 MHz to 20, 40, or 50

More information

Provides information for this release. Describes added functions for this release. Describes bug fixes in the released software version.

Provides information for this release. Describes added functions for this release. Describes bug fixes in the released software version. ANRITSU CORPORATION 5-1-1 Onna, Atsugi-shi, Kanagawa 243-8555 Japan Anritsu - GRL PCIe 3.0 CEM Rx Test Application Release Note First Edition This software is released for PCIe CEM Rx Test. Table of Contents

More information

Keysight E6964A Automotive Ethernet MDI S-parameter Compliance Solution

Keysight E6964A Automotive Ethernet MDI S-parameter Compliance Solution Keysight E6964A Automotive Ethernet MDI S-parameter Compliance Solution Medium Dependent Interface (MDI) S-parameter testing made more accurate for components being tested for 100BASE-T1 or BroadR-Reach

More information

Keysight Technologies On-Wafer Testing of Opto-Electronic Components Using the Lightwave Component Analyzers. Application Note

Keysight Technologies On-Wafer Testing of Opto-Electronic Components Using the Lightwave Component Analyzers. Application Note Keysight Technologies On-Wafer Testing of Opto-Electronic Components Using the Lightwave Component Analyzers Application Note Introduction When measurements of optoelectronic components are performed on

More information

icex-cmtm General specs and Installation guide

icex-cmtm General specs and Installation guide icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB

More information

N1014A SFF-8431 (SFP+)

N1014A SFF-8431 (SFP+) DATA SHEET N1014A SFF-8431 (SFP+) Compliance and Debug Application for 86100D DCA-X and N109X DCA-M Oscilloscopes Be Confident With Compliant Measurements Easy-to-use oscilloscope application that lets

More information

Keysight Technologies E4982A LCR Meter. 1 MHz to 300 MHz/500 MHz/1 GHz/3 GHz

Keysight Technologies E4982A LCR Meter. 1 MHz to 300 MHz/500 MHz/1 GHz/3 GHz Keysight Technologies LCR Meter 1 MHz to 300 MHz/500 MHz/1 GHz/3 GHz 02 Keysight LCR Meter 1 MHz to 300 MHz/500 MHz/1 GHz/3 GHz - Brochure New Standard for High-Speed Component Tests The Keysight LCR meter

More information

MIPI C-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET

MIPI C-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET The InterOperability Laboratory MIPI C-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET Abstract: This document serves as the primary documentation for the MIPI C-PHY Reference Termination

More information

OnCell G3100 Series Quick Installation Guide

OnCell G3100 Series Quick Installation Guide OnCell G3100 Series Quick Installation Guide Edition 4.1, August 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Keysight E5063A ENA Series Network Analyzer

Keysight E5063A ENA Series Network Analyzer Keysight E5063A ENA Series Network Analyzer 100 khz to 500 M/1.5 G/3 G/4.5 G/6.5 G/8.5 G/14 G/18 GHz Configuration Guide 02 Keysight E5063A ENA Series Network Analyzer - Configuration Guide Ordering Guide

More information

AKELA Vector Network Analyzer (VNA) Quick Start Guide

AKELA Vector Network Analyzer (VNA) Quick Start Guide AKELA Vector Network Analyzer (VNA) Quick Start Guide Copyright AKELA, Inc. 2012, all rights reserved http:\\akelainc.com LabVIEW and LabWindows are registered trademarks of National Instruments Incorporated

More information

Provides information for this release. Describes added functions for this release. Describes bug fixes in the released software version.

Provides information for this release. Describes added functions for this release. Describes bug fixes in the released software version. ANRITSU CORPORATION 5-1-1 Onna, Atsugi-shi, Kanagawa 243-8555 Japan Anritsu - GRL PCIe 4.0 CEM Rx Test Application Release Note First Edition This software is released for PCIe CEM Rx Test. Table of Contents

More information

USB Debug Adapter. Power USB DEBUG ADAPTER. Silicon Laboratories. Stop. Run. Figure 1. Hardware Setup using a USB Debug Adapter

USB Debug Adapter. Power USB DEBUG ADAPTER. Silicon Laboratories. Stop. Run. Figure 1. Hardware Setup using a USB Debug Adapter C8051F38X DEVELOPMENT KIT USER S GUIDE 1. Kit Contents The C8051F38x Development Kit contains the following items: C8051F380 Target Board C8051Fxxx Development Kit Quick-start Guide Silicon Laboratories

More information

What We Do. Fixturing and Fixture Removal for Multiport Devices with Non-Standard RF Interfaces. Fully automate for: Speed, Accuracy, Ease of Use

What We Do. Fixturing and Fixture Removal for Multiport Devices with Non-Standard RF Interfaces. Fully automate for: Speed, Accuracy, Ease of Use Fixturing and Fixture Removal for Multiport Devices with Non-Standard RF Interfaces What We Do Fully automate for: Speed, Accuracy, Ease of Use Calibration Validation To give confidence in test results

More information

Tech Note 16 XDS220 I/O Interface

Tech Note 16 XDS220 I/O Interface Tech Note 16 XDS220 I/O Interface Document Revision 0.01 November 26, 2012 Page 1 of 10 1 INTRODUCTION This technical note is a guide to operate the XDS220 I/O interface. The I/O interface supports the

More information

SWC1090 configuration software for G.M. International Isolators series D1000 and E1000. Installation and use manual

SWC1090 configuration software for G.M. International Isolators series D1000 and E1000. Installation and use manual SWC1090 configuration software for G.M. International Isolators series D1000 and E1000 Installation and use manual ISM0084-2 Installation and use of the SWC1090 calibration software Page 1 of 12 Index

More information

New Features in Firmware V2.02 (Compared to V2.01) New Features in Firmware V2.01 (Compared to V2.00)

New Features in Firmware V2.02 (Compared to V2.01) New Features in Firmware V2.01 (Compared to V2.00) What's New in this Revision This help describes version V2.10 of the R&S ZVA firmware. Compared to the previous version V2.02, the following True differential mode (option R&S ZVA-K6) Automatic calibration

More information

6220 Ethernet-Based Voltage Measurement Module

6220 Ethernet-Based Voltage Measurement Module 6220 Ethernet-Based Voltage Measurement Module Features 12 voltage inputs 16-bit, 100-kHz per channel sample rate ±10V input range Eight digital I/O Simultaneous sampling BNC connectors Multiple trigger

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

E36300 Series Triple Output Bench Power Supply DATA SHEET

E36300 Series Triple Output Bench Power Supply DATA SHEET E36300 Series Triple Output Bench Power Supply DATA SHEET Power Your Next Insight For more than 50 years, Keysight Technologies, Inc. DC power supplies have been changing the way engineers prove their

More information

USER MANUAL FOR FIOA-0402-U-16

USER MANUAL FOR FIOA-0402-U-16 USER MANUAL FOR FIOA-0402-U-16 COPYRIGHT NOTICE This manual is a publication of Renu Electronics Pvt. Ltd. and is provided for use by its customers only. The contents of the manual are copyrighted by Renu

More information

Agilent N5410A Fibre Channel Automated Test Application

Agilent N5410A Fibre Channel Automated Test Application Agilent N5410A Fibre Channel Automated Test Application Compliance Testing Methods of Implementation Agilent Technologies Notices Agilent Technologies, Inc. 2005 No part of this manual may be reproduced

More information

Keysight Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes

Keysight Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes Keysight Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes N5395C Ethernet Electrical Conformance Test Fixture N5396A Gigabit Ethernet

More information

C50- PARALLEL PORT INTERFACE CARD Rev. 1

C50- PARALLEL PORT INTERFACE CARD Rev. 1 C50- PARALLEL PORT INTERFACE CARD Rev. 1 User manual 1. Overview This card provides an easy way of interfacing your inputs and outputs from you parallel port. It provides terminals for the connections

More information

Triple Band Twin TMA (AWS/PCS/WCS) with AWS-3 and 700/850 Bypass

Triple Band Twin TMA (AWS/PCS/WCS) with AWS-3 and 700/850 Bypass DATA SHEET which includes AWS-3 and 700/850 Bypass Each TMA has independent gain control of 6 to 12dB Fail-safe bypass mode and multi-strike lightning protection Small lightweight unit offers high reliability

More information

AC/DC. Adapter. Ribbon. Cable Serial. Serial. Adapter. Figure 1. Hardware Setup using an EC2 Serial Adapter

AC/DC. Adapter. Ribbon. Cable Serial. Serial. Adapter. Figure 1. Hardware Setup using an EC2 Serial Adapter C8051F32X DEVELOPMENT KIT USER S GUIDE 1. Kit Contents The C8051F32x Development Kit contains the following items: C8051F320 Target Board C8051Fxxx Development Kit Quick-Start Guide C8051F32x Development

More information

Provides information for this release. Describes added functions for this release. Describes bug fixes in the released software version.

Provides information for this release. Describes added functions for this release. Describes bug fixes in the released software version. ANRITSU CORPORATION 5-1-1 Onna, Atsugi-shi, Kanagawa 243-8555 Japan Anritsu - GRL PCIe 4.0 BASE Rx Test Application Release Note First Edition This software is released for PCIe BASE Rx Test. Table of

More information

Agilent NFA Series Noise Figure Analyzers including the Agilent N8972A, N8973A, N8974A and N8975A NFA analyzers.

Agilent NFA Series Noise Figure Analyzers including the Agilent N8972A, N8973A, N8974A and N8975A NFA analyzers. Disclaimer: The Agilent NFA Microsoft Excel Data Acquisition Programming Example is provided "AS IS" for illustrative purposes only. Agilent Technologies makes no warranty with regard to programming examples.

More information

UsbScope.eu Manual. UsbScope.eu Manual. Version channel version

UsbScope.eu Manual. UsbScope.eu Manual. Version channel version Version 3.1 4 channel version Version 3.1 1 Sept-2011 Table of contents 1 Introduction...3 2 Hardware description...3 2.1 Specifications...3 2.2 PCB layout...4 2.3 Status LED s on 4 channel board...4 3

More information

Agilent PNA Series Microwave Network Analyzers

Agilent PNA Series Microwave Network Analyzers Agilent PNA Series Microwave Network Analyzers Configuration Guide PNA-L N5230A PNA-L N5230A PNA-X N5242A PNA E8362B PNA E8363B PNA E8364B PNA E8361A PNA N5250A 300 khz to 6, 13.5, or 20 GHz 10 MHz to

More information

Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines. Easily customizable to meet various test needs

Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines. Easily customizable to meet various test needs TC-5915A Shield Box Features High RF Shielding Easy Opening/Closing of lid EMI s on all Data and DC lines Easily customizable to meet various test needs Shock absorber on lid Specifications Mechanical

More information

UG352: Si5391A-A Evaluation Board User's Guide

UG352: Si5391A-A Evaluation Board User's Guide UG352: Si5391A-A Evaluation Board User's Guide The Si5391A-A-EVB is used for evaluating the Si5391A Any-Frequency, Any-Output, Jitter-Attenuating Clock Multiplier revision D. The device revision is distinguished

More information

Keysight Technologies PNA Series Microwave Network Analyzers

Keysight Technologies PNA Series Microwave Network Analyzers Keysight Technologies PNA Series Microwave Network Analyzers Configuration Guide PNA-L N5230A PNA-L N5230A PNA-X N5242A PNA E8362B PNA E8363B PNA E8364B PNA E8361A PNA N5250A 300 khz to 6, 13.5, or 20

More information

EDGES Receiver Calibration Steps Tom Mozdzen

EDGES Receiver Calibration Steps Tom Mozdzen EDGES Receiver Calibration Steps Tom Mozdzen January 23, 2018 This document provides a description of the steps required to calibrate an EDGES receiver. Detailed pictures and instrument settings as well

More information

Enabling MIPI Physical Layer Test

Enabling MIPI Physical Layer Test Enabling MIPI Physical Layer Test High Speed Test and Characterization High Speed Digital Test The Explosion of Functions within Mobile Devices Multiple RF functions GPS Bluetooth WCDMA GSM WLAN FM Multiple

More information

R&S IMS Software Configuration and System Calibration according to IEC / EN (conducted Immunity)

R&S IMS Software Configuration and System Calibration according to IEC / EN (conducted Immunity) Products: R&S IMS, R&S NRP-Z91 R&S IMS Software Configuration and System Calibration according to IEC / EN 61000-4-6 (conducted Immunity) Application Note This application note describes the software configuration,

More information

USB2.0 - Device. Universal Serial Bus Measurement

USB2.0 - Device. Universal Serial Bus Measurement USB2.0 - Device Universal Serial Bus Measurement www.tektronix.com 2015-05-05 REVISION RECORD SHEET Version Completion Initiator Page Date s 0.8 7-7-2014 S. Harrison 56 First Draft Nature of Change i ii

More information

Programmable Dual-Range DC Power Supplies 9170 & 9180 series

Programmable Dual-Range DC Power Supplies 9170 & 9180 series Data Sheet Programmable Dual-Range DC Power Supplies Outstanding performance combined with unique features The 9170/9180 series programmable DC power supplies offer industry leading performance, designed

More information

Field Calibration Software

Field Calibration Software SIGNAL HOUND Field Calibration Software User s Manual Version 1.0 9/25/2014 Requirements, Installation, Instructions, Usage Table of Contents 1 Introduction... 2 2 System Requirements... 2 3 Before Installing

More information

Programmable Dual-Range DC Power Supplies 9170B & 9180B Series

Programmable Dual-Range DC Power Supplies 9170B & 9180B Series Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com Data sheet Programmable Dual-Range DC Power Supplies 9170B & 9180B Series Outstanding performance combined

More information

LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY Tel: (845) , Fax: (845) Internet:

LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY Tel: (845) , Fax: (845) Internet: SDA-SAS Software Option Rev 1.1 Featuring LeCroy s Based on Clause 5 PHY Layer Tests from UNH-IOL Operator s Manual April 2006 LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY 10977 6499 Tel:

More information

GT Micro D High Speed Characterization Report For Differential Data Applications. Micro-D High Speed Characterization Report

GT Micro D High Speed Characterization Report For Differential Data Applications. Micro-D High Speed Characterization Report GT-14-19 Micro D For Differential Data Applications GMR7580-9S1BXX PCB Mount MWDM2L-9P-XXX-XX Cable Mount Revision History Rev Date Approved Description A 4/10/2014 C. Parsons/D. Armani Initial Release

More information

Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines. Easily customizable to meet various test needs

Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines. Easily customizable to meet various test needs TC-5915A Shield Box Features High RF Shielding Easy Opening/Closing of lid EMI filters on all Data and DC lines Easily customizable to meet various test needs Shock absorber on lid Specifications Mechanical

More information

AC/DC Adapter. Figure 1. Hardware Setup

AC/DC Adapter. Figure 1. Hardware Setup C8051F12X DEVELOPMENT KIT USER S GUIDE 1. Kit Contents The C8051F12x Development Kit contains the following items: C8051F120 Target Board Serial Adapter (RS232 to Target Board Debug Interface Protocol

More information

E5071C Adjustment Program. <Agilent Service Center Use Only> Operation Manual. Second Edition. Agilent Part No. N/A

E5071C Adjustment Program. <Agilent Service Center Use Only> Operation Manual. Second Edition. Agilent Part No. N/A E5071C Adjustment Program Operation Manual Second Edition Agilent Part No. N/A November 2006 Notices The information contained in this document is subject to change without notice. This document contains

More information

Direct Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements

Direct Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements Direct Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements Introduction For full two-port S-parameter measurements to extend PNA-C vector network

More information

Dimensions 49.5mm x 35mm PCB (56.5mm x 27mm including overhaning components) Stackable on 10mm pitch.

Dimensions 49.5mm x 35mm PCB (56.5mm x 27mm including overhaning components) Stackable on 10mm pitch. Specification DSL32M RevB1 Key Features Stackable bidirectional high voltage multiplexer 32 independent channel switches Handles up to +/-100V signals Low on resistance (15ohm large signals, 25ohm small

More information

keyestudio Keyestudio MEGA 2560 R3 Board

keyestudio Keyestudio MEGA 2560 R3 Board Keyestudio MEGA 2560 R3 Board Introduction: Keyestudio Mega 2560 R3 is a microcontroller board based on the ATMEGA2560-16AU, fully compatible with ARDUINO MEGA 2560 REV3. It has 54 digital input/output

More information

Keysight Technologies N6468A SFP+ Electrical Performance Validation and Conformance Software

Keysight Technologies N6468A SFP+ Electrical Performance Validation and Conformance Software Keysight Technologies N6468A SFP+ Electrical Performance Validation and Conformance Software For Infiniium Oscilloscopes Data Sheet 02 Keysight N6468A SFP+ Electrical Performance Validation and Conformance

More information

MASW Dual / Tri / Quaand GSM Applications Electrical Specifications: T A = 25 C, V C = 0V/2.5V, Z 0 = 50 Ω 4 Parameter Test Conditions Units Min

MASW Dual / Tri / Quaand GSM Applications Electrical Specifications: T A = 25 C, V C = 0V/2.5V, Z 0 = 50 Ω 4 Parameter Test Conditions Units Min MASW000105 Dual / Tri / Quaand GSM Applications Features Dual / tri / quadband GSM / GPRS / EDGE 2.5V Operation Harmonics: 70 c @ +34.5 m & 1 GHz Insertion Loss: 0.5 @ 1 GHz T X R X Isolation: 41 @ 2 GHz

More information

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure TRANSCOM INSTRUMENTS Product Brochure Transcom Instruments Product Brochure T5845A Matrix Vector Network Analyzer Overview T5845A is a new generation of multiport matrix vector network analyzer developed

More information

CheckSum. FUNC-2B Functional Test Module. The FUNC-2B features:

CheckSum. FUNC-2B Functional Test Module. The FUNC-2B features: CheckSum FUNC-2B Functional Test Module FUNC-2B Functional Test Module Made in U.S.A. The CheckSum Model FUNC-2B Functional Test System is designed to be used as an extension to a CheckSum ICT System.

More information

Keysight Technologies RF/Microwave Switching Solutions

Keysight Technologies RF/Microwave Switching Solutions Keysight Technologies RF/Microwave Switching Solutions Solution Brochure The core of test systems RF/Microwave signal routing without compromise Keysight RF/Microwave switching benefits Highly reliable

More information

Keysight E6963A Automotive Ethernet Link Segment Compliance Solution

Keysight E6963A Automotive Ethernet Link Segment Compliance Solution Keysight E6963A Automotive Ethernet Link Segment Compliance Solution Harness and Connector testing made easy for your 100BASE-T1 components Data Sheet 02 Keysight E6963A Automotive Ethernet Link Segment

More information

8 Channel Video Receive Unit with 2 Bi-directional Data and Audio Channels plus Ethernet for a Dual Redundant multimode fibre ring.

8 Channel Video Receive Unit with 2 Bi-directional Data and Audio Channels plus Ethernet for a Dual Redundant multimode fibre ring. AMG3684BxEDRSF Instruction Manual 8 Channel Video Receive Unit with 2 Bidirectional Data and Audio Channels plus Ethernet for a Dual undant multimode fibre ring. The AMG3684BxEDRSF is a standalone eight

More information

The UFC-6000 can measure the frequency of a signal from 1 to 6000 MHz. Mini-Circuits

The UFC-6000 can measure the frequency of a signal from 1 to 6000 MHz. Mini-Circuits Wide Frequency Range RF Frequency Counter 1-6000 MHz The Big Deal USB HID device compatible with 32/64 bit operating systems Wide Frequency Range Uses internal or External reference Supplied with proprietary

More information

USB Debug Adapter. Power USB DEBUG ADAPTER. Silicon Laboratories. Stop. Run. Figure 1. Hardware Setup Using a USB Debug Adapter

USB Debug Adapter. Power USB DEBUG ADAPTER. Silicon Laboratories. Stop. Run. Figure 1. Hardware Setup Using a USB Debug Adapter C8051F32X DEVELOPMENT KIT USER S GUIDE 1. Kit Contents The C8051F32x Development Kit contains the following items: C8051F320 Target Board C8051Fxxx Development Kit Quick-Start Guide AC to DC Power Adapter

More information

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. Monitoring of inverters and string combiner boxes (up to 64 devices); Complete configuration of the monitoring system

More information

DisplayPort 1.4 Webinar

DisplayPort 1.4 Webinar DisplayPort 1.4 Webinar Test Challenges and Solution Yogesh Pai Product Manager - Tektronix 1 Agenda DisplayPort Basics Transmitter Testing Challenges DisplayPort Type-C Updates Receiver Testing Q and

More information

User Guide User Guide DOC. NO REV. F ECN

User Guide User Guide DOC. NO REV. F ECN QuickSyn MICROWAVE FREQUENCY SYNTHESIZER User Guide User Guide DOC. NO. 5580513-01 REV. F ECN 001779 National Instruments 4600 Patrick Henry Drive, Santa Clara CA 95054 408-610-6810 ni-microwavecomponents.com

More information

AWG2300. USB Multifunction Arbitrary Waveform Generator SCICORE INSTRUMENTS, INC.

AWG2300. USB Multifunction Arbitrary Waveform Generator SCICORE INSTRUMENTS, INC. AWG2300 USB Multifunction Arbitrary Waveform Generator Simultaneous dual channel waveform generation DC - 50 MHz output frequency range Waveform sampling rate: 300MS/s Waveform vertical resolution: 14-bit

More information

USER S MANUAL. C35S- QUICK SETUP BREAKOUT BOARD Rev. 1.3

USER S MANUAL. C35S- QUICK SETUP BREAKOUT BOARD Rev. 1.3 USER S MANUAL C35S- QUICK SETUP BREAKOUT BOARD Rev. 1.3 FEBRUARY, 2015 USER'S MANUAL TABLE OF CONTENTS Page # Contents 1.0 OVERVIEW... 1 2.0 FEATURES... 1 3.0 SPECIFICATIONS.... 2 4.0 BOARD DESCRIPTION...

More information

1. SG-WRITER Components

1. SG-WRITER Components Index 1 SG-WRITER Components 1 2 USB Driver Installation 2 3 Software Installation 3 4 Operation Procedures 5 5 Operation Buttons 7 6 Calculate Button 7 7 Write and Test 8 8 Monitor 8 9 Help 8 10 Configuration

More information

Data Logger / Network Gateway

Data Logger / Network Gateway TX CONTROL INSTRUMENTATION EDGE-DL/NG-TP002 Data Logger / Network Gateway Product Description The Entek EDGE series Data Logger and Network Gateway (DL/NG) provides reliable logging of process or sensor

More information

Connection Procedure of WAGO CANopen Bus Coupler and Pro-face AGP-3****-CA1M/LT. Instruction Manual. Version1.1 (

Connection Procedure of WAGO CANopen Bus Coupler and Pro-face AGP-3****-CA1M/LT. Instruction Manual. Version1.1 ( Connection Procedure of WAGO CANopen 750-337 Bus Coupler and Pro-face AGP-3****-CA1M/LT Instruction Manual Version1.1 (2013.11.01) Copyright 2008 by WAGO Kontakttechnik GmbH All rights reserved. WAGO Kontakttechnik

More information

Agilent Custom Switch Matrices. Product Note

Agilent Custom Switch Matrices. Product Note Agilent Custom Switch Matrices Product Note Table of Contents 9 0 5 5 6 6 8 8 Introduction The function of the switch matrix Electrical specifications Switch drivers Switch matrix designs Mechanical specifications

More information

User Guide USB Frequency Counter

User Guide USB Frequency Counter User Guide USB Frequency Counter UFC-6000 1 to 6000 MHz Input Impedance: 50 Ω Dynamic Range: -28 to +13dBm Important Notice This guide is owned by Mini-Circuits and is protected by copyright, trademark

More information