IC-1600 INTELLIGENT CONTROLLER. Installation & User's Guide. Page 1 Copyright 2009, Access Specialties International, LLC All Rights Reserved

Size: px
Start display at page:

Download "IC-1600 INTELLIGENT CONTROLLER. Installation & User's Guide. Page 1 Copyright 2009, Access Specialties International, LLC All Rights Reserved"

Transcription

1 IC-1600 INTELLIGENT CONTROLLER Page 1 Copyright 2009, Access Specialties International, LLC All Rights Reserved

2 Table of Contents Introduction pg 3 Specifications pg 3 Host and Power Connections pg 4 System Device Connections pg 4 System Device Connections pg 5 IC-1600 Installation Diagram pg 6 Connecting the IC-1600 with RS-232 Communicaitons pg 7 Hardware Steps Pin Settings pg 7 Software Steps How to add a panel pg 7 Panel Info pg 7 Settings/Channel Leds pg 8 Memory Configuration Button/Memex pg 8 Updating pg 8 Notes pg 8 Turning PCW Off pg 8 Connecting with RS-485 Communications pg 9 Hardware Steps Pin Settings/Cable Connnection pg 9 RS-485 Comm Board pg 9 RS-485 Converter pg 9 RS-485 Software Steps pg 9 Connecting with RS-232 Dial-up modem pg 10 Hardware Steps IC-1600 Pin Settings pg 10 Modem Recommendations pg 10 Cable settings pg 10 Software Steps Panel Info pg 10 The Updating Tab pg 10 The Panelcom.ini File pg 11 Downloading the Database pg 12 Modem pin Settings and Command Key pg 13 US Robotics Control Strings pg 13 Clearing NV Ram for Modems pg 13 Modem Command Key pg 14 Table 1.1(Panel Addresses) pg 14 Table 1.2 (Memory Allocation Table) pg 15 Current Version Page 2 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

3 INTRODUCTION The IC-1600 Intelligent Controller works in conjunction with the Windows -based Access Gold or ASI 2000 Access Security Integrator software application. It is a stand-alone interface that could potentially control up to 256 devices (using Channel Expanders). The IC-1600 can be connected by RS-232 direct or dial-up, RS-485, and TCP/IP via a serial hub. Up to 4 IC-1600 s may be connected to one computer using RS- 232 direct connections. RS-485 connection allows up to 16 panels to be connected to the computer. Connections for battery back up are also provided. The IC-1600 can also be referred to as a Panel. SPECIFICATIONS Size: 12 1/4" x 14 1/4" x 4 1/4" Power Requirements: 60 Hz, 1A UL Listed or Hz,.5A Operating Temperature: -40 C to +75 C The IC-1600 is UL listed as a stand-alone system. The Access Gold, ASI2000 software programs and related computer equipment are supplementary and are not UL Listed. The IC Vac version is not UL listed. This product has not been investigated by UL for the use of standby operating power. Terminals designated as Battery + and Battery shall not be connected to a standby battery. The use of this equipment in the fail safe or fail secure mode or with Listed panic hardware is installation dependent. The Acceptability of these configurations is subject to approval by the local authority having jurisdiction. UL Listed equipment includes the IC-1600, CE-1600, RI-110/120/130, CC-165 and the PR-100. Unlisted devices include the ECM- 10, TC-100. Please refer to the CE-1600, RI-110/120/130 and CC-165 for additional installation instructions. Page 3 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

4 CONFIGURATION HOST & POWER CONNECTIONS (J5 & J18) J5 on the smaller daughter board provides the following connections for host communication. J18 on the larger motherboard provides the following connections for power hook up. Battery back-up connections are also provided. Host J5 Transmit Pin #1 Receive Pin #2 Clear To Send Pin #3 Unused Pin #4 Ground Pin #5 Power J18 120VAC Pin #1 120VAC Pin #2 Ground Pin #3 Battery- Pin #4 (24VDC) Battery+ Pin #5 SYSTEM DEVICE CONNECTIONS (J1 - J16) The IC-1600 has 16 Channels available for connecting readers and other system devices. The IC-1600 requires a 4-wire connection to each system device. The cable should be 22 gauge-shielded cable, consisting of 2 twisted pair. J1 through J16 on the motherboard provide the following connections for system device hook up. Each Channel has the same wiring configuration as shown below: Channel Connector - Pin# Function 0 J1 - Pin #1 Data + Pin #2 Data - Pin #3 Enable + Pin #4 Enable - 1 J2 - Pin #1 Data + Pin #2 Data - Pin #3 Enable + Pin #4 Enable - Page 4 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

5 SYSTEM DEVICE CONNECTIONS (CONTINUED) Channel Connector - Pin# Function 2 J3 - Pin #1 Data + Pin #2 Data - Pin #3 Enable + Pin #4 Enable - 3 J4 - Pin #1 Data + Pin #2 Data - Pin #3 Enable + Pin #4 Enable - (NOTE: This wiring pattern continues through J16.) 15 J16 - Pin #1 Data + Pin #2 Data - Pin #3 Enable + Pin #4 Enable - WIRING LEGEND Channel 0 Channel 8 Channel 1 Channel 9 Channel 2 Channel 10 Channel 3 Channel 11 Channel 4 Channel 12 Channel 5 Channel 13 Channel 6 Channel 14 Channel 7 Channel 15 Page 5 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

6 IC-1600 INSTALLATION DIAGRAM J TX RX Ground Daughter Board Data+ Data J1 J Enable+ Enable- Data+ Data- Enable+ Enable- J2 J10 J3 J11 J4 J12 J5 J13 J6 J14 J7 Power Supply J15 J8 J18 J VAC 120VAC Ground Battery- Battery+ (24VDC) Mother Board Page 6 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

7 CONNECTING THE IC-1600 WITH RS-232 COMMUNICATIONS Hardware Steps: PIN Settings/Cable Conections All switches should be OFF for S2 when connecting in RS-232 communications. If using Access Gold software on the host, also turn pin 6 on S1 to the ON position. Access Specialties provides a 15 RS-232 cable with each IC The blue wire is the transmit, the white wire is the receive, and the orange wire is the ground. The blue wire goes to pin 1 on J5 of the IC-1600, the white wire goes to pin 2 on J5 of the IC-1600, and the orange wire goes to pin 5 on J5 of the IC The maximum distance, in normal RS-232 communications, is 50. This length can be extended up to 10,000 with the use of short-haul modems. Software Steps (How to add a Panel): In Access Gold, click on the System Device button on the far left side of the screen. Select Device Defintitions. This screen brings up all of the devices in the security system. Press F5 on the keyboard to add a device. Highlight the IC and click on OK. There are several different tabs that organizes the information for the panel. In ASI 2000, open the Device Center module where you will see a Default Zone. Highlight the Zone for which you are defining the panel and right click. This will display the option to Add a Panel. Select this option to call up the Panel Definition window. You will see several tabs that are used to define the panel. These tabs are described in the following paragraphs. Panel Info Tab In Access Gold, each panel requires a Panel # which is a user-definable number between 1-32,765. For ASI2000, this number is optional. The Location field is the panel label or full description of where it is located. The field that states, The ID # of this Panel s PC, is linked with the panelcom.ini file. The number in the, The ID # of this Panel s PC, must match with the PCID line in the panelom.ini file local to that computer. When there are multiple panelcom computers, then each PCID number of each panelcom.ini file will be a different number. For ASI 2000, this field is called Panel Manager ID. Com Port identifies the serial port to which the IC-1600 is connected. When entering a Com Port number in the range between 1-4, Access Gold will automatically enter the commercial standard IRQ and Address Range. These settings may be entered by the user, if they do not match the actual values for the computer s com port. With Access Gold version 3.01b and later or ASI 2000, a Com port number may be defined up to 32. Page 7 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

8 Settings Tab/Channel Led s This is the location where the Channel of a specific IC-1600 can be turned ON or OFF. A checkmark indicates that a channel is ON. When a channel is ON, and communicating properly to a device, then the LED for that channel will flash continuously. Channels should be turned OFF, when there is not a device connected to it. This will allow efficient polling to the connected devices. If a channel is ON, while the the device connected to the channel is not comunicating properly, then there may be a delay for that IC-1600 s overall functions. This delay can also be caused by unused Ports on a CE-1600 that are turned ON. Unused Ports on the CE-1600 can be turned OFF with dip-switches. See the CE manual for more information on this. Memory Configuration Button/Memex Under the Settings Tab is the Memory Configuration button. This button takes the user to the screen that sets up the memory for the IC Setting up memory is done with ALL IC-1600 s. This must be done as the IC-1600 is first defined (preferably while PCW or Panel Manager is not running for that IC- 1600). The memory settings depend on the the size of the database fields and the memory capabilities of the IC Table 1.2, on page 16 illustrates the appropriate settings for a panel with a memex and for a panel without a memex. Memex stands for Memory Expansion Module. A memex is required on all IC s allocated for 1000 cardholders or more. Updating Tab In the RS-232 direct connection configuration, always define the panel to be updated continuously. This is also the same for RS-485 panels and panels using short-haul modems to communicate to the computer. RS-232 Dial-up modem communications is the only connection type that may allow a panel to be updated on a schedule. Notes Tab The Notes Tab is available for you to enter any comments, installation notes, etc. that you may have on that specific device. The system also lists when the panel was defined and each time the device defintion is changed. Every log entry will note the Date, Time and which operator made the changes. Access Gold - Turning off a Panel from PCW Turning off a panel from PCW means that the panel will not be polled when PCW is running. Turning off a panel from PCW is rather simple. First stop PCW and determine what the PCID numbers are for all of the Panelcom computers. The PCID number can be found in the panelcom.ini file. If there is only one panelcom machine then the default PCID is 1. You need to change one field for each panel that you want to turn off from PCW. Change the field that is under the Panel Info tab that states The ID # of this panel s PC to a PCID number that has not been used. There are several situations that would benefit from turning off a panel from Page 8 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

9 Access Gold - Turning off a Panel from PCW (Continued) PCW. For example, if there is a problem with communications for a specific panel communicating to PCW and PCW talks to multiple panels, then it is easier to troubleshoot the problem with all panels turned OFF from panelcom except for the panel that is experiencing commuication problems. Another scenario is if the user suspects that a panel that was recently downloaded to is not consistent with the database on the computer. If there are multiple panels communicating to PCW, then turning PCW OFF from all other panels ensures a quicker and cleaner download to the panel that has a suspect database. ASI Turning off a Panel from Panel Manager Under the Options menu in Panel Manager, you can select Turn Transactions On/Off so that it will not poll the panel. When you select this option, you will see that you can turn the Transactions on or off by clicking on the check box next to the panel and then on Save. CONNECTING THE IC-1600 WITH RS-485 COMMUNICATIONS Hardware Steps: Pin Settings To select RS-485 communications for the IC-1600, turn pin 2 on S2 to the ON position. If using Access Gold software on the host, also turn pin 6 on S1 to the ON position. If multiple IC-1600 s are connected to one RS-485 converter, then a unique address must be assigned to each IC This is done on pins 4-8 on S2. See Table 1.1 on page 14 for the address key. This address must be the same as the address specified in the IC-1600 device definition. One Com port may communicate up to a maximum of 16 IC-1600 panels. RS-485 COM Board Install the RS-485 COM board onto the IC-1600 s CPU11 board. To attach the COM board to the CPU11 board, connect the low number on the RS-485 COM board to the low number on the CPU11 board. Normally, it is J1 to J7. If you noted that the panel would be used with RS-485 communications, then this COM board will already be installed. RS-485 Converter Next,install the RS-485 converter. Access Specialties recommends the B&B Electronics Converter. The model number is 485ptbr and their phone number is (815) On the converter jumper the T+ to R+ and jumper T- to R-. Connect T+ to pin 2 and T- to pin 1on J5 of the IC Page 9 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

10 Computer s COM Port 3 Daisy-chained IC-1600 s RS-485 Software Steps: Follow the same steps noted above for adding a new panel, but specify RS-485 communications in the Panel Information tab of the IC You will also note the address of the IC The address must match the address configured on S2 of the IC-1600 panel. The rest of the tabs in the IC-1600 definition (Settings, Memory Configuration, Updating, and Notes) can be entered the same way as a regular RS-232 direct connect panel. CONNECTING THE IC-1600 TO AN RS-232 DIAL-UP MODEM Hardware Steps: PIN Settings To select RS-232 dial-up communications for the IC-1600, turn pin 1 on S2 to the ON position. If using Access Gold software on the host, also turn pin 6 on S1 to the ON position. If multiple IC-1600 s are dialing to one modem at the computer, a unique address must be assigned to each IC This is done on pins 4-8 on S2. See Table 1.1 (page 15) for the address key. This address must be the same as the address specified in the IC-1600 definition. One com port may communicate with up to a maximum of 32 IC-1600 panels with Access Gold Version 3.01b or above or ASI On many popular modems, including the US Robotics brand, the CTS (Clear To Send) line will always reflect the power-on/power-off status of the modem. The IC-1600 can monitor this line and reset the modem configuration in the event the modem is powered on after the panel (which can happen if you need to powercycle the modem to reset it). This will disable modem operation if you don t have the CTS line wired correctly, so this monitor mode is optional. Turn ON pin 8 on S1 to enable modem monitoring if you know you have a compliant cable, otherwise leave pin 8 on S1 in the OFF position. Modem Recommendations Access Specialties recommends and supports the US Robotics, external, Sportster modems. Control Strings are provided for the 14.4, 28.8, 33.3 and 56k speed modems. Page 10 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

11 Cable Customization There are 2 ways to ensure that the cable from the IC-1600 to the modem is configured properly. First, we recommend that you use the cable that comes with the IC-1600, in conjunction with a 25-to-9 pin converter. The cable that comes with the IC-1600 has jumpers in the cable already made by Access Specialties. You must also make sure that pin 2 on the RS-232 connector goes to pin 2 on J5 of the IC-1600 and pin 3 on the RS-232 pin 1 on J5 of the IC If you are planning on using the modem monitoring feature, then pin 8 on the RS-232 connector goes to pin 3 on J5. If a 25-to-9 pin converter can not used be with the ASI cable, then a cable may be made from scratch. Here are the steps: 1. Get a 25 pin serial cable 2. Jumper pin 4 to pin 5 3. Jumper pin 6 to pin Take pin 7 on the cable to pin 5 on J5 of the IC Take pin 3 on the cable to pin 2 on J5 of the IC Take pin 2 on the cable to pin 1 on J5 of the IC Take pin 5 on the cable to pin 3 on J5 of the IC-1600 Com Ports A dial-up panel may connect to a com port of 5 or higher (only up to 24) if using PCW1_6_5.exe. Prior versions may loose the carrier due to alarms and other activity on PCW. Software Steps: Panel Info Tab The IC-1600 needs to be configured as a dial-up panel. In the Panel Info tab, change the Connection Type to RS-232 dial-up modem. Enter the address for the IC-1600 that is configured on pins 4-8 on S2. Also enter the phone number for the IC-1600 s modem. Only numbers and commas can be entered in this field. Commas are used when an initial number is required to be pressed to dial an outside line. (For example: 9,, would be a valid entry for the phone number in area code of 612, with the main number ) The default Initialization String and the Dial prefix that automatically come up should work for all US Robotics modems. The Updating Tab When PCW or Panel Manager are calling only one panel, then the panel can communicate to PCW continuously. The continuous communications is set in the Updating tab. You would also set the communications to continuous whenever you want initiate a database download to a dial-up panel. If there is more than one panel calling the PCW or Panale Manager machine, then these panels will have to communicate on different schedules. This is also accomplished by changing the Page 11 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

12 The Updating Tab (Continued) Updating tab of the IC-1600 device definition. Each panel should have their own schedule. Each panel must be contacted at a different beginning Times and/or Dates. This does not affect alarms. Panels will immediately call the computer to report an encountered alarm. Alarms are reported by each panel as the alarm is generated. Alarms with Alarm Response Commands only function with panels that communicate continuously with PCW or Panel Manager. Access Gold - The Panelcom.ini File When installing a dial-up panel, you must make changes in the panelcom.ini file. The following lines must be added to this file to allow the panel to call PCW back. The only time a panel calls back PCW is when the panel has encountered an alarm to report back to the PCW modem. The number 1 signifies which com port the IC-1600 is connected to. Modem1=9600,N,8,1 ModemInit1=AT&FE0Q0V1X4S0=0&C1&B1&A0&W0&U6&N6 RetryInterval=3 TransactionThreshold=75 DialBack=FALSE When all Panels in the Database use the same phone numbers when calling to report each IC-1600 s alarms, you would add the following lines below. Phone1 would be the primary number and Phone2 is the secondary number. The commas for Phone2 signify one second pauses, which helps when a number is required to dial on an outside line. Phone1= Phone2=9,, When Panels need individual phone numbers because of different area codes, you would add the following line items to the.ini file. Each panel can be downloaded two Phone numbers a & b. PhoneList=true PhonePanel1a= PhonePanel1b= PhonePanel2a= PhonePanel2b= Downloading the Database to a Dial-up Modem Panel Each dial-up panel should be downloaded the database individually. When reallocating to a dial-up panel, the panel must be defined as continuously under the Updating tab. (Reallocating is downloading the database to the IC-1600). Once the database has been completely downloaded to the panel, that panel may be put back on a schedule for updating by Access Gold. Page 12 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

13 Note that all changes made to a panel s definition will not be seen by PCW until PCW is re-started. That includes all tabs except for the Settings tab. Default settings for the US Robotics Sportster Modems Switch settings for the modem attached to the IC-1600: 1,3,4, and 8 On (Down) Switch settings for the modem attached to the PCW Computer: 3,4,5 and 8 On (Down) Default US Robotics modem settings for the IC-1600 definition ATE0Q0V1X4&D0L0S0=2 Initialization strings for the Panelcom.ini file String for US Robotics Sportster 14.4 Faxmodem AT&FE0Q0V1X4L1S0=0&C1M1&B1&A0&W0 String for US Robotics Sportster 28.8 Faxmodem AT&FE0Q0V1X4L1S0=0&C1M1&B1&A0&W0&U6 String for US Robotics Sportster 33.3 and 56k Faxmodem AT&FE0Q0V1X4S0=0&C1&B1&A0&W0&U6&N6 String for US Robotics V.92 Faxmodem ATE0Q0V1X4&D0M0S0=0&N6&U6S15=191S32=248 Note: If the modems are not connecting properly to each other, clearing the NVRAM may resolve this. a) Power down the modem b) Completely disconnect the modem from the system and power it down c) Set dip switch 7 to ON (down) d) Reconnect power and power up modem e) Wait 5 seconds, then power down the modem f) Set dip switch 7 to OFF (up) g) Reconnect modem from the system and power up modem Page 13 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

14 Here are explanations of each command that make up the strings for the US Robotics Modems: E0 -Echo off Q0 -Display result codes V1 -Verbal codes (not numeric) X4 -Result code set &D0 -DTR Override L0 - Low speaker volume S0=2 -Auto-answer in 2 rings (for Panel) &A0 -ARQ reult codes disabled &N6 -Sets connection speed at hangs up if not at this speed *US-Robotics only &B1 -Sets modem s serial port rate to a fixed rate *US-Robotics only &K0 -Data compression disabled *US-Robotics only &F -back to factory defaults L1 - Low/medium speaker volume S0=0 -Disables auto-answer mode for (For panelcom) &C1 -Carrier Detect mode normal M1 -Speaker on until connected &W0 -Writes current configuration to NVRAM template &U6 -Sets floor connect speed at 9600 *US-Robotics only S15=191 - Forces modem to disable MNP compression S32=248 - Forces modem to use only 9600 baud modulation types Descriptions for each dipswitch setting for US Robotics Sportster: 1 -On (down) Ignores DTR 3 -Enables result codes 4 -Suppress Echo 5 -On (down) disables auto-answer 8 -Smart mode Enables recognition of AT Command set Page 14 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

15 Panel Switch Settings for Address: Table 1.1 SW Address OFF OFF OFF OFF OFF 0 OFF OFF OFF OFF ON 1 OFF OFF OFF ON OFF 2 OFF OFF OFF ON ON 3 OFF OFF ON OFF OFF 4 OFF OFF ON OFF ON 5 OFF OFF ON ON OFF 6 OFF OFF ON ON ON 7 OFF ON OFF OFF OFF 8 OFF ON OFF OFF ON 9 OFF ON OFF ON OFF 10 OFF ON OFF ON ON 11 OFF ON ON OFF OFF 12 OFF ON ON OFF ON 13 OFF ON ON ON OFF 14 OFF ON ON ON ON 15 ON OFF OFF OFF OFF 16 ON OFF OFF OFF ON 17 ON OFF OFF ON OFF 18 ON OFF OFF ON ON 19 ON OFF ON OFF OFF 20 ON OFF ON OFF ON 21 ON OFF ON ON OFF 22 ON OFF ON ON ON 23 ON ON OFF OFF OFF 24 ON ON OFF OFF ON 25 ON ON OFF ON OFF 26 ON ON OFF ON ON 27 ON ON ON OFF OFF 28 ON ON ON OFF ON 29 ON ON ON ON OFF 30 ON ON ON ON ON 31 Page 15 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

16 Table 1.2 Memory Allocation Table Table Description IC-1600 With Memex IC With Memex Recommendations Maximums Total # of Devices Elevator Floor Selector Max # of Floor Lists Max # Floors per List Time Zones Time Zone Intervals Alarm Definitions 30% above actual # 1000 Card Holders 30% above actual # Access Groups Total Holidays (all lists) 30% above actual # 255 Scheduled Commands 30% above actual # 1000 Future Commands 30% above actual # 1000 Conditional Response 30% above actual # 1000 Table Description IC Without Memex IC Without Memex Recommendations Maximums Total # of Devices actual + future needs Elevator Floor Selector 30% above actual # 5 Max # of Floor Lists 30% above actual # 5 Max # Floors per List 30% above actual # 5 Time Zones Time Zone Intervals Alarm Definitions 30% above actual # 1000 Card Holders 30% above actual # 1000 Access Groups double 2 actual # 255 Total Holidays (all lists) 30% above actual # 255 Scheduled Commands 30% above actual # 1000 Future Commands 30% above actual # 1000 Conditional Response 30% above actual # This is the number of devices you anticipate adding in the future. Making this number larger than necessary wastes memory in the panel, but if it s too small you may have to increase it in the future which will require that the panel be reallocated. 2 Most installations eventually use more access groups than they originally anticipated. Making this number larger than necessary wastes memory in the panel, but if it s too small you may have to increase it in the future which will require that the panel be reallocated. Total memory used is number of devices multiplied by number of access groups. Page 16 Copyright 2009, Access Specialties International, LLC All Rights Reserved.

UP-2000 Universal Panel Installation & User's Guide

UP-2000 Universal Panel Installation & User's Guide Copyright 2009, Access Specialties International, LLC All Rights Reserved. UP-2000 Universal Controller Table of Contents Introduction--------------------------------------------------------------- pg

More information

Designer Modem Communication US Robotics Sportster Modems

Designer Modem Communication US Robotics Sportster Modems Designer Modem Communication US Robotics Sportster Modems This Technical Note contains the information required to setup up the Designer to UniOP modem communication using US Robotics Sportster modems.

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

Configuring a Sunny Boy Control With an External Modem. Technical Note

Configuring a Sunny Boy Control With an External Modem. Technical Note With an External Modem Technical Note Revision 1.3 August 27, 2002 Kent Sheldon Revision History 1.0 July 1, 2002 Kent Sheldon Original Release 1.1 July 10, 2002 Kent Sheldon Add USR Modem 1.2 August 16,

More information

Installation and Operation Guide. KMD 5559 CommTalk

Installation and Operation Guide. KMD 5559 CommTalk Installation and Operation Guide Contents KMD 5559 CommTalk Description...3 Models...3 Specifications...3 Accessories...4 Mounting...5 Connecting the KMD 5559...5 Connecting power...9 Operation...9 Using

More information

x2 COMMANDS & TECHNICAL REFERENCE

x2 COMMANDS & TECHNICAL REFERENCE x2 COMMANDS & TECHNICAL REFERENCE NOTE: Until now, 33.6 Kbps was thought to be the practical limit for speed over standard phone lines. Now x2 technology shatters that barrier to bring you download speeds

More information

RS K Ext Modem. User Manual

RS K Ext Modem. User Manual RS-232 56K Ext Modem User Manual Content 1. Introduction... 2 2. Features... 3 3. Installation... 4 3.2.1 Installation Procedures for Windows 64 bits (XP/Win7/Vista)... 6 3.2.2 Installation Procedures

More information

TALKBACK INTERCOM SYSTEM V-2926 OPTION BOARD

TALKBACK INTERCOM SYSTEM V-2926 OPTION BOARD Issue 8 TALKBACK INTERCOM SYSTEM V-2926 OPTION BOARD The V-2926 Option Board is an add-on feature for the V-2924A Expandable Zone Talkback Intercom System. The addition of this board provides the following

More information

Starzone 4000 Master Control Panel Figure 2.1 Master Control Panel

Starzone 4000 Master Control Panel Figure 2.1 Master Control Panel Starzone 4000 Master Control Panel Figure 2.1 Master Control Panel The heart of the Starzone 4000 system is the Starzone Master controller (SZM-4000). Each AHU that is to be zoned will have its own SZM-4000

More information

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50 MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287 Installation and Operations Manual 00-02-0651 09-01-09 Section 50 In order to consistently bring you the highest quality, full featured products,

More information

Low Speed Modems for Dial and Leased Circuits 2400E (Standalone) 2400R (Rackmount)

Low Speed Modems for Dial and Leased Circuits 2400E (Standalone) 2400R (Rackmount) Low Speed Modems for Dial and Leased Circuits 2400E-030-4 (Standalone) 2400R-030-4 (Rackmount) QUALITY COMMUNICATIONS PRODUCTS Made in the U.S.A. 11-1010-002 INTRODUCTION The Data Connect ST2400E-2 and

More information

IML 560 USER GUIDE. Low Power 56Kbps Industrial modem. Version 1.2. December 6, AYANTRA Inc.

IML 560 USER GUIDE. Low Power 56Kbps Industrial modem. Version 1.2. December 6, AYANTRA Inc. IML 560 USER GUIDE Low Power 56Kbps Industrial modem Version 1.2 December 6, 2002 AYANTRA Inc. Revision History Date Version Description By November 18, 2002 1.1 Initial Release - December 6, 2002 1.2

More information

Instruction Manual Communications Software for iseries and C Series Instruments Part number Apr2014

Instruction Manual Communications Software for iseries and C Series Instruments Part number Apr2014 iport Instruction Manual Communications Software for iseries and C Series Instruments Part number 102606-00 22Apr2014 2007 Thermo Fisher Scientific Inc. All rights reserved. Specifications, terms and pricing

More information

NMCnet User Manual. Table of Contents

NMCnet User Manual. Table of Contents NMCnet Table of Contents NMCnet Basic Requirements... 3 nstallation NMC Net Communication Program... 4 Network Setup... 5 Local Network... 5 Modem Network... 7 Modem Communication Setting... 7 Demo Network...

More information

TechMemo # B. AlphaEclipse and Alpha signs. See Alpha and AlphaEclipse sign data formats on page 13 for a list of signs.

TechMemo # B. AlphaEclipse and Alpha signs. See Alpha and AlphaEclipse sign data formats on page 13 for a list of signs. TechMemo #01-0011B PRIORITY: Normal DATE: August 26, 2004 TITLE: ECO REFERENCE: PRODUCT(S) AFFECTED: SUMMARY: US Robotics 56k modem setup for AlphaEclipse and Alpha signs n/a AlphaEclipse and Alpha signs.

More information

ELK-M1XSP Serial Port Expander

ELK-M1XSP Serial Port Expander ELK-M1XSP Serial Port Expander Supplementary Instructions & Release Notes for Firmware Version 70.X.X This version provides M1 Integration to: HAI OmniStat Series 2 and Series 1 Thermostats Table of Contents

More information

GE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001. Quick Start Guide GFK-2912 October 2014

GE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001. Quick Start Guide GFK-2912 October 2014 GE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001 Quick Start Guide GFK-2912 October 2014 g Contents 1. User Features...1 1.1. Overview... 1 1.2. Restart

More information

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,

More information

Installation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter

Installation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter Installation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter Introduction The USB to Octal Serial Adapter is designed to make serial port expansion quick and simple. Connecting to a USB port on your

More information

VCMDM MODEM INSTALLATION INSTRUCTIONS

VCMDM MODEM INSTALLATION INSTRUCTIONS Issue 1 www.class-connection.com VCMDM MODEM INSTALLATION INSTRUCTIONS The VCMDM Modem Package allows the user to program the Class Connection TM or VC-24 System from an off-site location. This document

More information

STAR Comm Modem Kit for the Micro/PX-2000: Setup Instructions

STAR Comm Modem Kit for the Micro/PX-2000: Setup Instructions STAR Comm Modem Kit for the Micro/PX-2000: Setup Instructions This STAR Comm Modem Kit was designed specifically for use with the Micro/PX-2000 micro. The STAR Comm Modem is an external modem that can

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

ZM24x Quick-Connect Industrial Modem. User s Manual

ZM24x Quick-Connect Industrial Modem. User s Manual ZM24x Quick-Connect Industrial Modem User s Manual Version 1.1 2004 ZYPEX, Inc. All Rights Reserved 1 ZM24x Quick-Connect Industrial Modem Since the equipment explained in this manual has a variety of

More information

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new Controller.

More information

EA500. Installation Instructions Transponder

EA500. Installation Instructions Transponder EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the

More information

PV3500. Fuel Site Controller. Service Manual OPW Fuel Management Systems Manual M Rev. 1

PV3500. Fuel Site Controller. Service Manual OPW Fuel Management Systems Manual M Rev. 1 PV3500 Fuel Site Controller Service Manual 2002 OPW Fuel Management Systems Manual M11-00.03 Rev. 1 OPW Fuel Management Systems - System and Replacement Parts Warranty Statement Effective September 1,

More information

3.1 I-7560 Pin Assignment and Specifications: Introduction

3.1 I-7560 Pin Assignment and Specifications: Introduction 3.1 I-7560 Pin Assignment and Specifications: Introduction The I-7560 adds a Windows serial Com port via its USB connection and is compatible with new & legacy RS-232 devices. USB Plug and Play allows

More information

TALKBACK INTERCOM SYSTEM V-2928 OPTION BOARD

TALKBACK INTERCOM SYSTEM V-2928 OPTION BOARD TALKBACK INTERCOM SYSTEM V-2928 OPTION BOARD The V-2928 Option Board is an add-on feature for the V-2924A Expandable Zone Talkback Intercom System. The addition of this board provides the following supplemental

More information

ATL20 ATL30 Automatic transfer switch controller

ATL20 ATL30 Automatic transfer switch controller I 194 GB 07 07 ATL20 ATL30 Automatic transfer switch controller REMOTE CONTROL SOFTWARE MANUAL Summary Introduction... 2 Minimum resources of the PC... 2 Installation... 2 Activation of the PC-ATL connection...

More information

GTWIN 1.1 CONTROL TECHNOLOGY CORPORATION. GTWIN 2.8 Quick Start. MGT Panel & GTWIN Quick Start Guide

GTWIN 1.1 CONTROL TECHNOLOGY CORPORATION. GTWIN 2.8 Quick Start. MGT Panel & GTWIN Quick Start Guide GTWIN 1.1 CONTROL TECHNOLOGY CORPORATION GTWIN 2.8 Quick Start MGT Panel & GTWIN Quick Start Guide CONTROL TECHNOLOGY CORPORATION MGT Panel & GTWIN Quick Start Guide Copyright 2004-2007 Control Technology

More information

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer)

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer) Version: 2016-08-18 Multi-IQ Firmware: (Serial Number / Seriennummer) RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable User manual MANUAL ENGLISH... 2 GENERAL PROPERTIES:... 2

More information

Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000

Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000 Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000 1.0 Introduction A Technical Application Note from Doppler Systems April 11, 1999 Version 3.x of the DDF6000, running

More information

Frontline Test System

Frontline Test System Frontline Test System Serialtest Async Serialtest Spy for Windows 9x/NT Manual Technical Support Frontline Test Equipment, Inc. PO Box 7507 Charlottesville, VA 22906-7507 USA Voice: (804) 984-4500 Fax:

More information

FSA-CU Configuration Utility Programming Guide

FSA-CU Configuration Utility Programming Guide FSA-CU Configuration Utility Programming Guide Revision 3 October 2013 Introduction The following guide will show you the basics of the FSA-CU configuration utility program. The CU can be used with the

More information

USB-Link 2 Technical Guide. USB-Link 2 Code: SS0073 Version 4.11 and up

USB-Link 2 Technical Guide. USB-Link 2 Code: SS0073 Version 4.11 and up USB-Link 2 Technical Guide USB-Link 2 Code: SS0073 Version 4.11 and up TABLE OF CONTENTS GENERAL INFORMATION... 3 USB-Link 2 Overview... 3 System Requirements... 3 QUICK GUIDE...4 USB-LINK 2 DRIVER INSTALLATION

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology 485DRCI RS-232 RS-485 2-Wrie RS-422/485 4-Wire RS-232 CON. RS-422/485 CON. Data Rate Isolation Surge Protection Industrial Bus Source Input Voltage Power Consumption Connector p/n 7207r3 485DRCI-4108ds

More information

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM. 8 Port USB to RS- 232/422/485 Octal Adapter Product Manual Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM 2 USB-8COMi-RM Product Manual Revision History Revision Date Author Comments

More information

Sutron Voice Modem Operation Manual

Sutron Voice Modem Operation Manual Sutron Voice Modem Operation Manual Models: 8080-0005-1 and -2 TABLE OF CONTENTS Overview...1 Jumpers and Connections...2 Recommended Jumper Settings...2 Operation with the Xpert/Xlite...3 Operation with

More information

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual The USB to industrial 16-Port RS-422/485 Adapter is designed to make serial port expansion quick and simple. Connecting to a USB port on your

More information

Application Note CTAN #131

Application Note CTAN #131 Application Note CTAN #131 The application note is pertinent to all CT drives with RS232 communications. Remote Modem Communication with Drives This document will detail the use of a modem to allow use

More information

Introduction & Specifications of Hi-Speed USB to Serial Adapters

Introduction & Specifications of Hi-Speed USB to Serial Adapters Introduction & Specifications of Hi-Speed USB to Serial Adapters The USB Serial Adapters consist of the following models: USB Single Serial Adapter (ES-U-1001, ES-U-1001-A) USB Single Serial Adapter (ES-U-1001-M,

More information

Getting Started Guide for the Remote Access Dial-in Ethernet Modem 9300-RADES

Getting Started Guide for the Remote Access Dial-in Ethernet Modem 9300-RADES Getting Started Guide for the Remote Access Dial-in Ethernet Modem 9300-RADES - Unpacking your 9300-RADES - Setting up 9300-RADES for an Ethernet Connection - Setting up 9300-RADES for a Modem Connection

More information

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany LAN-Modem Operation Manual E121711217066 Bär Industrie-Elektronik GmbH Siemensstr. 3 D-90766 Fürth Germany Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com COPYRIGHT Copyright

More information

USB-Link 2 Technical Guide

USB-Link 2 Technical Guide www.wattmaster.com USB-Link 2 Technical Guide USB-Link 2 Code: SS0073 Version 4.11 and up TABLE OF CONTENTS GENERAL INFORMATION... 3 USB-Link 2 Overview... 3 System Requirements... 3 QUICK GUIDE...4 USB-LINK

More information

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter ICD105A 1008 page 1/5 7319 r001 ICD105A Industrial RS-232 to RS-422/485 Converter Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

ELK-M1XSP Serial Port Expander

ELK-M1XSP Serial Port Expander -M1XSP Serial Port Expander Supplementary Instructions & Release Notes for Firmware Version 30.X.X This version provides M1 Integration to: JetStream ing Table of Contents M1XSP Installation and Setup...

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

CTI CALL INFORMATION INTERFACE

CTI CALL INFORMATION INTERFACE CTI CALL INFORMATION INTERFACE MODEL CN-4750 SERIAL/ITEM 533/nnn OPERATOR MANUAL Issue 3, FEB, 2002 AUTHOR: PETER ZEUG PATENTS PENDING DESIGNED AND MANUFACTURED IN AUSTRALIA DESIGN TWO THOUSAND PTY LTD

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules Modular Access Control System The next generation of the PW-Series family improves on the existing PW technology to offer superior features and benefits. The PW-Series Modular Control System is an advanced

More information

This 4-port RS-422/485 Adapter is provided with an external switching power adapter in the package.

This 4-port RS-422/485 Adapter is provided with an external switching power adapter in the package. USB-4COMi-M USB to Quad RS-422/485 to Serial Adapter Manual The USB to Industrial Quad RS-422/485 Adapter is designed to make industrial communication port expansion quick and simple. Connecting to a USB

More information

Quick Start Installation Guide

Quick Start Installation Guide istar Pro Quick Start Installation Guide Version B0 Part Number UM-069 January 2005 OVERVIEW This guide defines all of the commonly used connection methods to the istar Pro. It outlines how to wire readers

More information

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual The USB-COMi-TB USB-to-Industrial Single RS-422/485 Adapter is designed to make industrial communication port expansion quick and simple.

More information

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem ZM56 High-Speed Industrial Modem Command Summary 1 ZM56 High-Speed Industrial Modem AT Command Summary Command AT ATA ATDT ATE0 ATE1 ATH ATH1 ATI ATO ATS Description Attention Prefix Precedes all commands

More information

Rev Cutler-Hammer Smart Breaker Panel Control Manual

Rev Cutler-Hammer Smart Breaker Panel Control Manual 026-70 Rev 0 6-0-03 Cutler-Hammer Smart Breaker Panel Control Manual 640 Airport Road, Suite 04 Kennesaw, GA 3044 Phone: (770) 425-2724 Fax: (770) 425-939 ALL RIGHTS RESERVED. The information contained

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

Installation Instructions for UL Rev A

Installation Instructions for UL Rev A NetController II Installation Instructions for UL 864 30-3001-1008 Rev A Mounting Screw Andover Continuum Power Supply Connector Third-Party Power Supply Connector I/O Bus Connector Cover Mounting Screw

More information

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09 CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.

More information

Intelligent Devices IDI 1100 Series Technical Manual

Intelligent Devices IDI 1100 Series Technical Manual Intelligent Devices IDI 1100 Series 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights Reserved

More information

CommLink IV Technical Guide

CommLink IV Technical Guide www.wattmaster.com CommLink IV Technical Guide Table of Contents General Information... 3 CommLink IV Overview...3 Optional IP Module Kit...3 Optional Remote Link II...3 Installing CommLink IV ONLY...3

More information

Diagram 1. Copper wire connections. Preferred method on connecting several units.

Diagram 1. Copper wire connections. Preferred method on connecting several units. TroubleShooting Communicating with Telephone Access Equipment Whether managing one or multiple telephone access units, communications is the most sensitive part of managing a system. Everyone in the communication

More information

VISY-X. Technical Documentation. Cinterion MC 55 i. Edition: Version: 1 Article no.:

VISY-X. Technical Documentation. Cinterion MC 55 i. Edition: Version: 1 Article no.: Technical Documentation VISY-X Edition: 2016-10 Version: 1 Article no.: 350033 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Tel.: +49 / 40 / 39 82 07 0 Fax: +49 / 40 / 39 06 339 Table of contents

More information

EV Evaluation System User Guide. Contents. Kit Contents. Introduction

EV Evaluation System User Guide. Contents. Kit Contents. Introduction Contents EV2200 40 Evaluation System User Guide Section Page No. Introduction 1 Kit Contents 1 Hardware and Software Setup 2 Software Installation 2 Hardware Connection 2 Operation 2 Starting the Program

More information

DGH A3000 Configuration Guide For use with DGH Modules

DGH A3000 Configuration Guide For use with DGH Modules DGH A3000 Configuration Guide For use with DGH Modules Revision Date: 12/07/05 Version: 1.00 Contact Information: http://www.dghcorp.com Ph: (603) 622-0452 Fax: (603) 622-0487 Mailing Address: DGH Corporation

More information

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...

More information

Canlan INSTALLATION MANUAL

Canlan INSTALLATION MANUAL Canlan INSTALLATION MANUAL August 2014 Table of Contents Introduction... 4 Overview... 5 RJ45 Connector and Status LEDs... 5 Power Input... 6 RS232 / RS485 Connectors... 7 Installing the Canlan Software...

More information

4.7 Expansion Module MAC00-FS1/FS4

4.7 Expansion Module MAC00-FS1/FS4 MAC00-FS4 With M12 connectors MAC00-FS1 With D sub connectors TT1068GB 4.7.1 High speed serial RS485 module MAC00-FS1 and FS4 Introduction The MAC00-FS1 and FS4 are used for high speed RS485 communication

More information

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud

More information

Using Yaskawa CM049 BACnet Option with Delta Controls DSM-RTR

Using Yaskawa CM049 BACnet Option with Delta Controls DSM-RTR Using Yaskawa CM049 BACnet Option with Delta Controls DSM-RTR 1. INTRODUCTION: The following information describes utilizing the Yaskawa E7U and P7U Variable Frequency Drives with Yaskawa s CM049 BACnet

More information

IP Module Technical Guide

IP Module Technical Guide www.wattmaster.com IP Module Technical Guide Table of Contents General Information... 3 IP Module Overview...3 System Overview...3 System Requirements...3 Quick Start Guide... 4 CommLink IV IP Module Installation...

More information

RS-422/485 PCIe Card

RS-422/485 PCIe Card RS-422/485 PCIe Card User Manual Ver. 3.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2 Features...

More information

NDM Configurator. Introduction Page *3. Configuration Files 5. Downloading 17 APPLICATION NOTE

NDM Configurator. Introduction Page *3. Configuration Files 5. Downloading 17 APPLICATION NOTE System 9100 Technical Manual 636.4 Network Communications Section Application Note Issue Date 0896 APPLICATION NOTE NDM Configurator Introduction Page *3 Configuration Files 5 Hardware Requirements *5

More information

User Manual Revision: A04 June 23, QuEST Rail LLC.

User Manual Revision: A04 June 23, QuEST Rail LLC. User Manual 095-110006- 0003 Revision: A04 June 23, 2015 2015 QuEST Rail LLC. QLCP User Manual Page 2 Contents About This Manual... 4 Customer Support... 4 1 Get to Know Your QLCP... 5 2 DIP Switch and

More information

RS-422/485 PCI Card User Manual Ver All brand names and trademarks are properties of their respective owners.

RS-422/485 PCI Card User Manual Ver All brand names and trademarks are properties of their respective owners. RS-422/485 PCI Card User Manual Ver. 2.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2 Features...

More information

ARC Modem Low Power Modem LP9624

ARC Modem Low Power Modem LP9624 Over a decade of service to the Data Commination Industry 800-926-0226 / 281-392-6333 ARC Modem Low Power Modem LP9624 After 5 seconds of inactivity, the unit automatically goes into power down mode The

More information

Installation Guide of Hi-Speed USB to Industrial I/O Adapter

Installation Guide of Hi-Speed USB to Industrial I/O Adapter Installation Guide of Hi-Speed USB to Industrial I/O Adapter Introduction of USB-COMi-SI-M The USB Industrial I/O Adapter is designed to make industrial communication port expansion quick and simple. Connecting

More information

FieldServer X-25 Start-Up Guide

FieldServer X-25 Start-Up Guide Sierra Monitor Company FieldServer X-25 Start-Up Guide APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after April 2013 Kernel Version: 6.10 Document Revision: 0 FieldServer FS-X25 Start-Up

More information

TC1900 "QUICK TALK" RS-232 or Fiber Telephone Extender User's Manual

TC1900 QUICK TALK RS-232 or Fiber Telephone Extender User's Manual "QUICK TALK" RS- or Fiber Telephone Extender MODEL: S/N: DATE: Notice! Although every effort has been made to insure that this manual is current and accurate as of date of publication, no guarantee is

More information

CAMit I Camera with built in Modem

CAMit I Camera with built in Modem CAMit I Camera with built in Modem User s Manual CAMit I AP revision: 3.3 CAMit I Setup revision: 2.0.1 Manual revision: 2.0 Date: February 27, 2002 Congratulations You just acquired a fine product from

More information

EasySYNC Ltd. USB to Serial Converters Manual

EasySYNC Ltd. USB to Serial Converters Manual EasySYNC Ltd Document Reference No.: ES_000061 Issue Date: 2011-01-26 The ES-U-xxxx-x adapters are a series of USB Serial Converters from EasySYNC Ltd. They provide a simple method of adapting legacy RS-232

More information

CONTROLS.COM. Bacnet and Modbus Modules. T3-22i. T3000 Building Automation System Overview. T3-8o. Ethernet MAIN NET1 RS485 SUBNET2 RS485.

CONTROLS.COM. Bacnet and Modbus Modules. T3-22i. T3000 Building Automation System Overview. T3-8o. Ethernet MAIN NET1 RS485 SUBNET2 RS485. TEMCO CONTROLS.COM Bacnet and Modbus Modules T3-22i T3000 Building Automation System Overview Building Operator T3-8o Ethernet Internet T3-BB T3-LB T3-TB T3-8o T3-22i Remote User MAIN NET1 RS485 TSTAT8

More information

ACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL

ACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL ACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL 01/2004 Centaur is a registered trademark of Position Technology INC. Pro-Report, Tracker, FrontGuard and FrontView are trademarks of Position Technology Inc.

More information

HOUSING DEVICES, INC. HDI ADA - ARCU. Installation & Operations Manual. Made in the USA

HOUSING DEVICES, INC. HDI ADA - ARCU. Installation & Operations Manual. Made in the USA HOUSING DEVICES, INC. ADA - ARCU Installation & Operations Manual Made in the USA ADA - ARCU 5 & 10 Pre-Installation Requirements: For each ADA-1000 in the elevator you must run a twisted, shielded, 22

More information

RTU8 Compact Telemetry Outstation IOTOOL32 PRO Software. Getting Started Guide

RTU8 Compact Telemetry Outstation IOTOOL32 PRO Software. Getting Started Guide 1 RTU8 Compact Telemetry Outstation IOTOOL32 PRO Software Getting Started Guide V. 1.00 / Feb 2006 / Doc 40031 2 1. Introduction The RTU8 range of Compact Telemetry Outstations provide an efficient and

More information

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer This manual explains how to connect the HiDMUX2700 HART Multiplexer and configure Yokogawa s Plant Resource Manager (PRM) software.

More information

I-7570 Serial To HART Converter

I-7570 Serial To HART Converter I-7570 Serial To HART Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original

More information

Page 1 MRK-D-0011, V2.0 Aeroqual SM50 User Guide

Page 1 MRK-D-0011, V2.0 Aeroqual SM50 User Guide Page 1 Table of Contents User Guide Revision History... 3 Description... 4 1. Operating Instructions... 4 1.1. Power... 4 1.2. Warm Up... 4 1.3. Standard Inputs and Outputs... 4 1.4. Using the Relay Output...

More information

Compact utility outstation / EN/IEC slave RTU870 with additional mirrored 101 Slave driver INTRODUCTION VERSIONS/ORDERING CODES

Compact utility outstation / EN/IEC slave RTU870 with additional mirrored 101 Slave driver INTRODUCTION VERSIONS/ORDERING CODES INTRODUCTI VERSIS/ORDERING CODES This data sheet is an appendix to the general RTU870 data sheet. It covers RTU870 with a additional mirrored IEC870-5-101 Slave driver on the RS232 Meter port (COM3 which

More information

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China. FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection

More information

OVEN INDUSTRIES, INC.

OVEN INDUSTRIES, INC. OVEN INDUSTRIES, INC. OPERATING MANUAL MODEL 5C7-195 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Page Features...1 Description...2 Block Diagram...2 Mechanical Package Drawing...3 RS232

More information

180 Series Keypad. Handbook. Revision 2.1

180 Series Keypad. Handbook. Revision 2.1 180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique

More information

DFS/Cutter. Debugging Communication Problems

DFS/Cutter. Debugging Communication Problems DFS/Cutter Technical Support Bulletin Debugging Communication Problems Abstract: This TSB is written to help users debug communication problems where the cutter appears to ignore everything the computer

More information

Size of Mounting Plate /2 inches High x 7 inches Wide x 3 1/16 inches Deep (includes circuit boards)

Size of Mounting Plate /2 inches High x 7 inches Wide x 3 1/16 inches Deep (includes circuit boards) Remote Control Panel The Remote Control Panel (RCP), used in conjunction with PM4, PM5, Advantage, and VF Telephone Entry (TE) systems, serves as the control hardware for related access control functions,

More information

Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter

Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter Introduction of USB-COMi and USB-COMi-SI The USB-COMi and USB-COMi-SI Industrial Single RS-422/485 Adapters are designed to make

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology 485DRCI Industrial RS-232 to RS-422/485 Converter p/n 7207r5 485DRCI-2212ds page 1/5 Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

IP Module Technical Guide

IP Module Technical Guide www.wattmaster.com IP Module Technical Guide Table of Contents General Information... 3 IP Module Overview...3 System Overview...3 System Requirements...3 Quick Guide... 4 CommLink IV IP Module Installation...

More information

IP Module Technical Guide

IP Module Technical Guide www.wattmaster.com IP Module Technical Guide TABLE OF CONTENTS GENERAL INFORMATION... 3 IP Module Overview... 3 System Overview... 3 System Requirements... 3 QUICK START GUIDE... 4 COMMLINK IV IP MODULE

More information

SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with NOVA.16 (SK-MRCP) 16-Door Panel

SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with NOVA.16 (SK-MRCP) 16-Door Panel SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with (SK-MRCP) -Door Panel WITH RS- GATEWAY CONNECTED DIRECTLY TO A PC RS- GATEWAY POWER: EIGHT (8) SMART READERS EVENLY SPACED UP TO 000

More information

Operating Instructions

Operating Instructions 33CS Comfort System Software CONTENTS Page GENERAL...1 OPERATION...1-11 Start-Up...1 Main Menu...2 CURSOR MOVEMENT AND FUNCTION SELECTION Initial Setup and Configuration...3 BASIC MODE EXPERT MODE MODEM

More information

USB to RS-422/485 Serial Adapter

USB to RS-422/485 Serial Adapter USB to RS-422/485 Serial Adapter User Manual Ver. 4.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2

More information