250A, 600VAC Electronic and Thermal-Magnetic
|
|
- Benjamin Strickland
- 6 years ago
- Views:
Transcription
1 250A, Electronic and Thermal- Dimensions 3P Fixed Version 8.07H x 4.13W x 4.07D Weight 6.18 (Ibs) General The breaker is a 250 amp frame with either a microprocessor based over current protective trip system or a thermal magnetic trip unit. Standards The UL489/CSA C22.2 No. 5 version of also carries an IEC rating. Versions To meet all application requirements, the is available in the following versions: T = Thermal-magnetic B = Selectable & adjustable LI or LS C = Adjustable LSI E = Adjustable LSIG D = Molded Case Switch E5 = Electronic instantaneous only (MCP) Functions These trip functions are available: L = Long time S = Short time I = Instantaneous G = Ground fault Performance Levels Each version is also available in different maximum fault interrupting levels: N = Normal S = Standard H = High - L = Extra high V = Very high - UL489 / CSA C22.2 Interrupting Capacity (ka RMS) Voltage Continuous Rating N S H L V 240VAC A VAC A A VDC (1) A VDC (2) A IEC Interrupting Capacity (ka RMS) Voltage Continuous Rating N S H L V 230VAC A VAC A VAC A VAC A VAC A VDC A Number of Poles (3) The is available as a 2, 3 and 4 pole breaker. The 2 and 3 pole versions have the same dimensions. Reverse Feeding All versions of the family are suitable for reverse feed application. (1) 2 poles in series. (2) 3 poles in series. (3) 2 pole breakers available in N version only. 4 pole breakers available in N and H version only. ABB 17
2 250A, Electronic (AC Only) -100A Frame, Electronic (AC Only) A Adjustable Range 2-Pole, 3-Pole, 4-Pole, N100BW-2 N100BW N100BW-4 N N100CW-2 N100CW N100CW-4 N100EW-2 N100EW N100EW-4 S100BW S S100CW S100EW H H100BW H100BW-4 H100CW H100CW-4 H100EW H100EW-4 L100BW L L100CW L100EW V100BW V V100CW V100EW -150A Frame, Electronic (AC Only) A Adjustable Range 2-Pole, 3-Pole, 4-Pole, N150BW-2 N150BW N150BW-4 N N150CW-2 N150CW N150CW-4 N150EW-2 N150EW N150EW-4 S150BW S S150CW S150EW H H150BW H150BW-4 H150CW H150CW-4 H150EW H150EW-4 L150BW L L150CW L150EW V150BW V V150CW V150EW V UL current limiting V150BW 100 V150CW V150EW -250A Frame, Electronic (AC Only) A Adjustable Range 2-Pole, 3-Pole, 4-Pole, N250BW-2 N250BW N250BW-4 N N250CW-2 N250CW N250CW-4 N250EW-2 N250EW N250EW-4 S250BW S S250CW S250EW H H250BW H250BW-4 H250CW H250CW-4 H250EW H250EW-4 L250BW L L250CW L250EW V250BW V V250CW V250EW 18 Discount Schedule DS-ST ABB
3 250A, Electronic 100% Rated (AC Only) NQ SQ HQ LQ VQ 3-Pole, NQ100BW NQ100CW NQ100EW SQ100BW SQ100CW SQ100EW HQ100BW HQ100CW HQ100EW LQ100BW LQ100CW LQ100EW VQ100BW VQ100CW VQ100EW -150A Frame, 100% Rated Electronic (AC Only) A Adjustable Range NQ SQ HQ LQ VQ 3-Pole, 600V NQ150BW NQ150CW NQ150EW SQ150BW SQ150CW SQ150EW HQ150BW HQ150CW HQ150EW LQ150BW LQ150CW LQ150EW VQ150BW VQ150CW VQ150EW -250A Frame, 100% Rated Electronic (AC Only) A Adjustable Range NQ SQ HQ LQ VQ 3-Pole, 600V NQ250BW NQ250CW NQ250EW SQ250BW SQ250CW SQ250EW HQ250BW HQ250CW HQ250EW LQ250BW LQ250CW LQ250EW VQ250BW VQ250CW VQ250EW ABB Discount Schedule DS-ST 19
4 250A, Thermal- s -250A Frame, Thermal- N S H L V Rating 3-Pole, /600VDC 4-Pole, /600VDC 20A 500 N020TW N020TW-4 30A (21-30A) 500 N030TW N030TW-4 40A (28-40A) 500 N040TW N040TW-4 50A (35-50A) 500 N050TW N050TW-4 80A (56-80A) N080TW N080TW-4 100A (70-100A) N100TW N100TW-4 125A (88-125A) N125TW N125TW-4 150A ( A) N150TW N150TW-4 200A ( A) N200TW N200TW-4 250A ( A) N250TW N250TW-4 20A 500 S020TW 30A (21-30A) 500 S030TW 40A (28-40A) 500 S040TW 50A (35-50A) 500 S050TW 80A (56-80A) S080TW 100A (70-100A) S100TW 125A (88-125A) S125TW 150A ( A) S150TW 200A ( A) S200TW 250A ( A) S250TW 20A 500 H020TW H020TW-4 30A (21-30A) 500 H030TW H030TW-4 40A (28-40A) 500 H040TW H040TW-4 50A (35-50A) 500 H050TW H050TW-4 80A (56-80A) H080TW H080TW-4 100A (70-100A) H100TW H100TW-4 125A (88-125A) H125TW H125TW-4 150A ( A) H150TW H150TW-4 200A ( A) H200TW H200TW-4 250A ( A) H250TW H250TW-4 20A 500 L020TW 30A (21-30A) 500 L030TW 40A (28-40A) 500 L040TW 50A (35-50A) 500 L050TW 80A (56-80A) L080TW 100A (70-100A) L100TW 125A (88-125A) L125TW 150A ( A) L150TW 200A ( A) L200TW 250A ( A) L250TW 20A 500 V020TW 30A (21-30A) 500 V030TW 40A (28-40A) 500 V040TW 50A (35-50A) 500 V050TW 80A (56-80A) V080TW 100A (70-100A) V100TW 125A (88-125A) V125TW 150A ( A) V150TW 200A ( A) V200TW 250A ( A) V250TW N Rating 2-Pole, /500VDC 30A (21-30A) 500 N030TW-2 40A (28-40A) 500 N040TW-2 50A (35-50A) 500 N050TW-2 80A (56-80A) N080TW-2 100A (70-100A) N100TW-2 125A (88-125A) N125TW-2 150A ( A) N150TW-2 200A ( A) N200TW-2 250A ( A) N250TW-2 20 Discount Schedule DS-ST ABB
5 250A, 100% Rated Thermal- s -250A Frame, 100% Rated Thermal- NQ SQ HQ LQ VQ Rating 3-Pole, /600VDC 20A 500 NQ020TW 30A (21-30A) 500 NQ030TW 40A (28-40A) 500 NQ040TW 50A (35-50A) 500 NQ050TW 80A (56-80A) NQ080TW 100A (70-100A) NQ100TW 125A (88-125A) NQ125TW 150A ( A) NQ150TW 200A ( A) NQ200TW 250A ( A) NQ250TW 20A 500 SQ020TW 30A (21-30A) 500 SQ030TW 40A (28-40A) 500 SQ040TW 50A (35-50A) 500 SQ050TW 80A (56-80A) SQ080TW 100A (70-100A) SQ100TW 125A (88-125A) SQ125TW 150A ( A) SQ150TW 200A ( A) SQ200TW 250A ( A) SQ250TW 20A 500 HQ020TW 30A (21-30A) 500 HQ030TW 40A (28-40A) 500 HQ040TW 50A (35-50A) 500 HQ050TW 80A (56-80A) HQ080TW 100A (70-100A) HQ100TW 125A (88-125A) HQ125TW 150A ( A) HQ150TW 200A ( A) HQ200TW 250A ( A) HQ250TW 20A 500 LQ020TW 30A (21-30A) 500 LQ030TW 40A (28-40A) 500 LQ040TW 50A (35-50A) 500 LQ050TW 80A (56-80A) LQ080TW 100A (70-100A) LQ100TW 125A (88-125A) LQ125TW 150A ( A) LQ150TW 200A ( A) LQ200TW 250A ( A) LQ250TW 20A 500 VQ020TW 30A (21-30A) 500 VQ030TW 40A (28-40A) 500 VQ040TW 50A (35-50A) 500 VQ050TW 80A (56-80A) VQ080TW 100A (70-100A) VQ100TW 125A (88-125A) VQ125TW 150A ( A) VQ150TW 200A ( A) VQ200TW 250A ( A) VQ250TW ABB Discount Schedule DS-ST 21
6 250A, MCP (Instantaneous Only), Molded Case Switch -250A Frame, Motor Control Protection (MCP) Electronic (AC Only) N PR221 DS-I S PR221 DS-I H PR221 DS-I L PR221 DS-I Type Rating Adjustment Range 3-Pole, 100A N100E5W 150A N150E5W 250A N250E5W 100A S100E5W 150A S150E5W 250A S250E5W 100A H100E5W 150A H150E5W 250A H250E5W 100A L100E5W 150A L150E5W 250A L250E5W -250A Frame, Molded Case Switch Type Amps 3-Pole, /600VDC 4-Pole, /600VDC N-D N250DW S-D S250DW H-D H250DW H250DW-4 L-D L250DW V-D V250DW 22 Discount Schedule DS-ST ABB
T4 250A, 600V Electronic and thermal magnetic trip units
Electronic and thermal magnetic trip units T3 H x W x D 8.07" x 4.13" x 4.07" General The T4 breaker is a 250 amp frame with either a microprocessor based over current protective trip system or a thermal
More information1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD
Molded Case Circuit Section Tri-Break Line Integrally Fused Thermal Magnetic Circuit Integrally Fused Magnetic Circuit Integrally Fused Molded Case Switches These breakers are available in three types.
More informationC E R T I F I C A T E O F C O M P L I A N C E
LG Frame, Types NLGB, HLGB and LLGB. These are two and three pole circuit breakers with non-interchangeable thermal magnetic and electronic trip units. They are uncompensated 40 o C construction rated
More information1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD
Molded Case Circuit Section Tri-Break Line Integrally Fused Thermal Magnetic Circuit Integrally Fused Magnetic Circuit Integrally Fused Molded Case Switches These breakers are available in three types.
More informationMiniature Circuit Breakers and Supplementary Protectors. Contents
. Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.
More information1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD
Molded Case Circuit Section Tri-Break Line Integrally Fused Thermal Magnetic Circuit Integrally Fused Magnetic Circuit Integrally Fused Molded Case Switches These breakers are available in three types.
More informationCERTIFICATE OF COMPLIANCE
Issued to: SIEMENS AG LOW VOLTAGE SIEMENSSTRASSE 10 93055 REGENSBURG GERMANY This is to certify that representative samples of CIRCUIT BREAKERS, MOLDED CASE AND CIRCUIT- BREAKER ENCLOSURES See Addendum
More informationUL 489 DIN rail branch circuit breakers
UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationTaxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V Molded case circuit breaker
4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96--468 GHB00 P 0A 77/4V Breaker Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More information9926 Series Branch Rated Circuit Breakers AC Version
Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering
More informationApplying branch circuit breakers and supplementary protectors in North America
Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North
More informationApplying branch circuit breakers and supplementary protectors in North America
Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More information4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...
.3 Product Description Drawout molded case circuit breaker switchboard Front accessible Front connected Through-the-door design drawout mechanism through 600A Insulated case UL 89 breakers up to 200A Visual
More informationSACE Emax 2 Specification guide
SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationThe City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2
The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results
More informationTaxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V
4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96--468 Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating circuit breaker type dimensions interrupt
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationModel: KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.
Model: KEP Automatic Transfer Switches Service Entrance Rated Controller D Decision-Makerr MPAC 1500 Ratings Power Switching Device Molded case (MCCB) Insulated Case (ICCB) Current Voltage, Frequency 200
More informationSupplemental Protectors
compact S200 Series Miniature circuit breakers S200, S200P, S200U, S200UP Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The S2 devices are
More informationWMS SUPPLEMENTARY PROTECTORS
WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationMULTI 9 System Catalog
MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault
More informationUL 489 Cable-In / Cable-Out Branch Circuit Breaker
Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationSelection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationGE Energy Industrial Solutions. GE Overcurrent Device Instantaneous Selectivity Tables
GE Energy Industrial Solutions GE Overcurrent Device Instantaneous Selectivity Tables Contents Introduction...3 Selectivity with EntelliGuard TU and microentelliguard EntelliGuard TU Trip Units in ANSI
More informationCERTIFICATE OF COMPLIANCE
Issued to: SIEMENS AG LOW VOLTAGE SIEMENSSTRASSE 10 93055 REGENSBURG GERMANY This is to certify that representative samples of CIRCUIT BREAKERS, MOLDED CASE AND CIRCUIT- BREAKER ENCLOSURES See Addendum
More informationEnabling a Solid State Circuit Breaker
Enabling a Solid State Circuit Breaker USING SOLID-STATE CIRCUIT BREAKERS TO REVOLUTIONIZE POWER DISTRIBUTION Mike Harris Atom Power, Inc. Copyright 2019 Atom Power, Inc. All rights reserved. Enabling
More informationMOUNTING BASE AQB-A402 PLAN VIEW OF MOUNTING BLOCK & CIRCUIT BREAKER AQB-A802 CIRCUIT BREAKER MOUNTING BLOCK 2.50 MOTOR OPERATOR 25.
Weights & Dimensions 4 1/8 4 5/16 4 1/8 4 5/16 Weights & Dimensions 5 1/16 6 1/2 15 1/2 17 15/16 A C A C 6 3/16 MOUNTING ASE MOUNTING ASE 5 1/16 6 3/16 MOUNTING ASE DIMENSIONS DESCRIPTION A C SINGLE ASE,
More informationClose Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors
Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationMicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers
MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers Easily replace electro-mechanical trip units with the latest electronic, digital trip unit technology Ensure
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options
More informationQuicklag Industrial Ground Fault Thermal-Magnetic Circuit Breaker, Single-Pole, 30 Ma Trip Sensitivity, 30A, 10 Kaic, 120V, Bolt-On Mounting
4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96--468 Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating interrupt rating Poles Trip Voltage
More informationIntroduction Circuit Protection
Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short
More informationIELR Rail-Mount Series Magnetic Circuit Protectors
IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series
More informationProduct Guide. UL 1077 DIN Rail Supplementary Protectors
Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................
More informationMicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers
MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers Easily replace electro-mechanical trip units with the latest electronic, digital trip unit technology Ensure
More informationTaxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V
4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96--468 Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating circuit breaker type dimensions interrupt
More informationPowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)
PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 0CT00R/0 0 CONTENTS Description..............................................Page Description.............................................
More informationReinforced discrimination
Reinforced discrimination Compact NSX Additional characteristics Contents Presentation Functions and characteristics A- Installation recommendations B- Dimensions and connection C- Wiring diagrams D- Compact
More information1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers
.2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................
More informationCert.Record No _0_000, Class No , DQD No 557 Rev SUPPLEMENTARY PROTECTORS COMPONENT ACCEPTANCE PROGRAM
Seite 1 von 6 ACCEPTANCE RECORD File No: Class No: 016186_0_000 321530 SUPPLEMENTARY PROTECTORS COMPONENT ACCEPTANCE PROGRAM SUBMITTOR 4544043 E-T-A Circuit Breakers Limited 100 Leek Cr, Unit 11 Richmond
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More informationAir & Moulded Case Circuit Breaker Service & Maintenance
Charnchanok T., Low Voltage Products Division Air & Moulded Case Circuit Breaker Service & Maintenance November 12, 2013 Slide 1 Air Circuit Breaker : New Emax Series Reliability and sturdiness - Materials
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationTmax molded case circuit breakers Specification guide
Tmax molded case circuit breakers Specification guide Tmax Specification Guide 1 Specification Number: 26 28 16.14 Product Name: MOLDED CASE CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings
More informationProduct Guide. UL 489 DIN rail miniature circuit breakers
Product Guide UL 489 DIN rail miniature circuit breakers UL 489 DIN rail miniature circuit breakers Product Overview................................................ 2 Product Selection WMZT 10 kaic at
More informationSECTION SWITCHBOARDS
SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS
More informationJtec 10kA Miniature Circuit Breaker
Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationAcquiSuite Ally 48 Advanced Branch Circuit Monitor
AcquiSuite Ally 48 Advanced Branch Circuit Monitor AMC48-MD AMC48-ED Split Core CT Split Core CT Ally Rogowski Rope CT DESCRIPTION The AcquiSuite Ally 48 is the perfect companion to the data acquisition
More informationSECTION DISCONNECT SWITCHES
SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationIELR Series
IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic
More informationI-Line Panelboards. Innovative design, smart bus technology, and simple installation
I-Line Panelboards Innovative design, smart bus technology, and simple installation TM Smart: designed for efficient installation Simple: Efficient Installation Process I-Line Breakers Main Lugs: Fixed-mounted
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationMiniature Circuit-Breaker IEC Series 8562
> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors
More informationPowerPact D-Frame Circuit Breakers and Switches 150 to 600 A
PowerPact D-Frame Circuit Breakers and Switches 150 to 600 A Catalog 0616CT0801 2010 Class 0616 CONTENTS Description............................................. Page General Information...........................................7
More informationECNR/ECSR Class RK5 Dual-Element Time-Delay Fuses. Catalog Number ECNR (1-600A) 250Vac or Less Catalog Number ECSR (1-600A) 600Vac or Less
Catalog Number ECNR ( - 600A) 250Vac or Less Catalog Number ( - 600A) 600Vac or Less Amp Ratings ECNR 8 25 70 50 400 2 9 30 75 75 450 3 35 80 200 500 4 2 40 90 225 600 5 5 45 250 6 7.5 50 300 7 20 60 25
More informationApplication Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400
Overcurrentswitch,10A,3p,C-Char,AC Partno. FAZ-C10/3 Articleno. 278869 CatalogNo. FAZ-C10/3 Similar to illustration Deliveryprogramme Product range FAZ Application Instantaneous release response current
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)
DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery
More informationMulti 9 System Catalog
Multi 9 System Catalog Catalog 0860CT00 R07/4 04 Class 860 CONTENTS CONTENTS Description............................................. Page Description Page Introduction..................................................7
More informationRFD-200 TM. Test a Wide Variety of Relays in their Outdo FEATURES AT A GLANCE. Auxiliary AC/DC Power Supply. RFD-200 S2 Ampere Meters
Ergonomic Design a Make Performance RFD-200 TM Vanguard s Model RFD-200 S2 is a portable relay test set that delivers performance verification testing of electromechanical, electronic, and microprocessorbased
More informationUL 508 A standard-compliant design of industrial control panel
UL 508 A standard-compliant design of industrial control panel Axel Jöhnke System Architecture Expert 14-15 SEPTEMBER 2011, MUNICH Agenda www.infoplc.net Origin and Comprehension Organizations Certificates
More informationEntelliGuard* G Circuit Breakers Don t compromise arc flash protection for system reliability.
GE Energy Management EntelliGuard* G Circuit Breakers Don t compromise arc flash protection for system reliability. The next chapter in the history of low-voltage circuit breakers EntelliGuard* G circuit
More information.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical
Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationProducts :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers
Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Hydraulic/Magnetic Circuit Breaker B-Series B-Series PDF elibrary The B-Series hydraulic/magnetic circuit breakers are compact and
More informationBulletin 1492-MC 1492-MCGA, -MCEA 1492-SP
Bulletin Control Circuit and Load Protection Product Overview Bulletin -MC -MCGA, -MCEA -SP Type Branch Ground Fault Detection Features /V, V & Y/V rating A interrupt / in. per pole wide... A @ UL Circuit
More informationDIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More informationIhr autorisierter Distributor: Neumüller Elektronik GmbH
IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 Neumüller Elektronik GmbH Gewerbegebiet
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT
More informationUL 489 or UL 1077 in control panels and equipment a quick guide
UL 489 or UL 1077 in control panels and equipment a quick guide A common question that comes up with OEM machine builders and control panel builders is How do I know when to use UL 1077 or UL 489 breakers
More informationMagnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158
Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70
More informationSupplementary Circuit Protectors Type GSB63
Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationMOLDED CASE CIRCUIT BREAKERS. SACE Tmax XT Break new ground UL and CSA Standards
MOLDED CASE CIRCUIT BREAKERS SACE Tmax XT Break new ground UL and CSA Standards S A C E T M A X X T M O L D E D C A S E C I R C U I T B R E A K E R S ( M C C B S U L & C S A S TA N D A R D S ) A molded
More informationModel Pole Rated Current (A)
1.) Molded Case Circuit Breaker (Fuji Electric) Molded Case Circuit Breaker Global Twin (NEW series) 2 Poles MCCB Model Pole Rated Current (A) Interrupting Capacity (ka) IEC 947-2 230 VAC 380 VAC (Bath)
More informationModel KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.
Model KEP Automatic Transfer Switches Service Entrance Rated Controller D Decision-Makerr MPAC 1500 Ratings Power Switching Device Molded case (MCCB) Insulated Case (ICCB) Current Voltage, Frequency 200
More informationModel KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.
Model KEP Automatic Transfer Switches Service Entrance Rated Controller D Decision-Makerr MPAC 1500 Ratings Power Switching Device Current Voltage, Frequency Molded case (MCCB) Insulated Case (ICCB) 200
More informationSpectra RMS Circuit Breakers with microentelliguard Trip Units
GE Energy Industrial Solutions Spectra RMS Circuit Breakers with microentelliguard Trip Units Greater system coordination, arc flash protection and reliability for new equipment and retrofit applications
More informationMaximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches
Series 300 Power Transfer Switches Maximum Reliability & Excellent Value With a Series 300 Transfer Switch, you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually
More informationCutler-Hammer. January 2001
Cutler-Hammer January 0 Vol.,Ref. 2-2 Product Line Overview January 0 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case Circuit s are designed to provide circuit protection for
More informationFor Sales and Support call KMParts.com (866)
Overcurrentswitch,5A,1p,B-Char,AC Partno. FAZ-B5/1 Articleno. 278528 CatalogNo. FAZ-B5/1 Similar to illustration Deliveryprogram Basic function Miniature circuit breakers Number of poles 1 pole Tripping
More informationD64RP18 INSTRUCTION MANUAL N.O. N.C V AC/DC TEST/ RESET
D64RP18 INSTRUCTION MANUAL N.O. N.O. CONTROL CIRCUIT N.C. N.C. CONTROL CIRCUIT 24-240V AC/DC L POWER SUPPLY N TEST/ RESET TEST/RESET PUSHBUTTON CT Wires EXTERNAL CORE BALANCE CT RATINGS PER IEC 60755 CT
More informationFunction permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%
Operating range: 0.10 to 30 xin (step 0.01) 50P(2) Activation level 100% Deactivation level 95% Timer accuracy: 30 ms Operating range: 0.10 to 30 xin (step 0.01) 50N/G(2) Activation level 100% Deactivation
More informationBulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications
Power Circuit Control Circuit (External Source) Control Circuit (Internal Source) Short Circuit Current Rating (SCCR) Application Electrical Ratings Three-phase Number of Poles 3 Input Power Terminals
More informationUS BROCHURE. Circuit protection according to UL 489 and UL 1077
US BROCHURE Circuit protection according to UL 489 and UL 1077 2 CIRCUIT PROTECTION UL 489 AND UL 1077 CIRCUIT PROTECTION UL 489 AND UL 1077 3 Table of contents 004 006 Introduction 007 008 Product selction
More informationGo to:
System PKZ 0 ectors 08/019 Clip plate Standard version Short version C-PKZ0 072900 C-PKZ0-K 206740 One of the clip plates is always necessary when combining a PKZM0 manual motor prr and a S(E)00 magnetic
More informationProtistor size 22x58 ar 690VAC (IEC) / 700VAC (UL)
690VAC (IEC) / VAC (UL) Protistor size 22x58 ar 690VAC (IEC) / VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS Low l²t for improved semiconductor
More informationCert.Record No _C_000, Class No , DQD No 548 Rev
Page 1 of 7 CERTIFICATION RECORD The company named below has been authorized by CSA International to represent the products listed in this record as CSA Certified and to affix the CSA Mark to these products
More information