Cert.Record No _C_000, Class No , DQD No 548 Rev
|
|
- Abigayle May
- 6 years ago
- Views:
Transcription
1 Page 1 of 7 CERTIFICATION RECORD The company named below has been authorized by CSA International to represent the products listed in this record as CSA Certified and to affix the CSA Mark to these products according to the terms and conditions of the CSA Service Agreement and applicable CSA program requirements (including additional Markings). File No: Class No: _C_ INDUSTRIAL CONTROL EQUIPMENT Motor Controllers-Magnetic SUBMITTOR Eaton Industries GmbH Hein-Moeller-Strasse 7-11 Bonn, Germany FACTORIES Eaton Electro Productie S.r.l. SC Moeller Electroproductie s.r.l. 8 Independenti Sarbi, Romania Eaton Electrical Ltd. 2# Lou Yang Road Weiting SIP Suzhou, Jiangsu China July 31, 2014 (Replaces: June 26, 2014) Contactors; Type DILM185A, DILM225A, XTCE 185H, XTCE 225H; DIL M185A-SOND730, DIL M225A- SOND730, XTCE 185H-S730 and XTCE 225H-S730, 3 poles; Open type; Operating coil 24 to 500Vac, 24 to 240Vdc; 200HP max., FLA: 192A max. at 600Vac max.; General use: 250A, 600Vac. Definite Purpose rating for Type DILM185A, XTCE 185H, DILM225A, XTCE 225H (-SOND730) 336A, (2016 LRA), 480 Vac, 50/60Hz 280A, (1680 LRA), 600 Vac, 50/60Hz Accessories: Cable terminal block for DILM185A/225A, Model No. DILM225A-XKU-S and XTCEXTLA225A. Note: Optional high fault rating: 50kA, 600 Vac; 65 ka, 480Vac (350 A Breaker) 100kA, 600 Vac (350 A Class J fuse) 100kA, 600 Vac (600 A Class J fuse)
2 Page 2 of 7 Contactors, Type DILM(C) followed by 300, 400, 500 or 570, may be followed by -S; 3 poles; open type; operating coil 24 to 500V ac/dc; 600V ac max; 500A max; 500hp max; FLA: 520A max. at 600V ac; FLA: 650A max. at 480V ac; version DILMC provided with spring force connectors. Starpoint Bridge Cat.Nos. DILM500-XSI. 1. These devices are open type, 3-pole contactors intended to connect motors directly across-the-line. 2. The devices are identical in construction only the ratings are different. 3. The DILMC version is provided with an alternate clamping terminal for the integrated coil terminal. 4. Standard short-circuit rating: 30kA, 600V (when protected by 800A Class L fuse or 600A circuit breaker) 5. Optional high fault rating: 42kA, 480V (when protected by 600A circuit breaker) 100kA, 600V (when protected by 600A class J Fuse) Contactors; Types DILM(C)17-, DILM(C)25-, DILM(C)32-, DILM(C )38-, XTC E(C) 017, XTC E(C) 025, XTC E(C) 032, DILMF(C)8-, DILMF(C)11-, DILMF(C)14-, DILMF(C)17-, DILMF(C)25-, DILMF(C)32-, DILMF(C)38- ; Reversing contactor prefixes DIULM(C)17-, DIULM(C)25-, DIULM(C)32- ; Followed by -10 or -01; Operating coil 12 to 240Vdc and 24 to 240Vac, 50-60Hz; Max. rating 3ph.: 25hp at 600Vac; Max. rating 1ph.: 5hp at 240Vac; Max. rating DC: 5hp at 240Vdc; General use: 40A at 600Vac, 40A at 250Vdc; Version DILMC provided with spring force connectors. Contactor with 4 poles catalogue number DILMP32 and DILMP45 followed by -10 or -01 Special rating: 40A, 600V ac Resistance Air Heating: 40A, 600V ac Refrigerator Control: 480V 600V FLA 40A 30A LRA 240A 180A DIL L-12: 24A, 600V ac Tungsten load 24A, 600V ac General use DIL L-18: 35A, 600V ac Tungsten load 35A, 600V ac General use DIL L-20 40A, 600V ac Tungsten load 40A, 600V ac General use Mechanical Interlock catalogue number DILM32-XMV 1. These devices are open type, 3 poles contactors intended to connect motors directly across the line. They are provided with an auxiliary contact normally opened (NO) or normally closed (NC) rated A600, P DILM(C) 17, DILM(C) 25, DILM(C) 32, XTC E(C) 017, XTC E(C) 025, XTC E(C) 032, series controllers have a short-circuit rating of 22KA at 600 Vac max, when protected by a thermo magnetic circuit breaker having an interrupting rating not less than 22kA rms symmetrical amperes at 600V sized not greater than 32 Amps. 3. DILM(C) 17, DILM(C) 25, DILM(C) 32, XTC E(C) 017, XTC E(C) 025, XTC E(C) 032, series controllers have a short-circuit rating of 100KA at 600 Vac max, when used in conjunction with type C396 overload relay, when protected by Class J fuses having an interrupting rating not less than 100kA rms symmetrical amperes at 600V sized not greater than the current values of the table below: DILM(C) 17, XTC E(C) 017 DILM(C) 25, XTC E(C) 025 Max Class J Non-Time Delay Fuse 70A 100A
3 Page 3 of 7 DILM(C) 32, XTC E(C) A Contactors; Type DILM(C) 7 -, DILM(C) 9 -, DILM(C) 12 -, DILM(C) 15 -, XTC E(C) , XTC E(C) , XTC E(C) , XTC E(C) 015 ; Reversing contactors prefix DIULM(C)7-, DIULM(C)9-, DIULM(C) 12- ; Followed by 10 or 01, may be followed by - SOND 516; Operating coil 12 to 220Vdc and 24 to 240Vac; Max. rating 3ph: 10hp at 600Vac, Max. rating 1ph.: 3hp at 240Vac; Max. rating DC: 2hp at 240Vdc; General use: 20A at 600Vac, 20A at 250Vdc; Version DILMC provided with spring force connectors; Version DILMP20 provided with 4 poles. Special rating: 10A, 600Vac Resistance Air Heating 20A, 600Vac Refrigeration Control FLA 10A, 600Vac LRA 60A, 600Vac Tungsten 24A, 600Vac Special Rating for DILM(C) 7, XTC E(C) Elevator control: 3hp at 600Vac Special Rating for DILM(C) 9, XTC E(C) and DILMP20 Elevator control: 5hp at 600Vac Special Rating for DILM(C) 12, XTC E(C) and DILM(C) 15, XTC E(C) 015 Elevator control: 7.5hp at 600Vac Mechanical Interlock catalogue number DIULM12-XMV. 1. These devices are open type, 3 poles contactors intended to connect motors directly across the line. They are provided with an auxiliary contact normally opened (NO) or normally closed (NC) rated A600, P DILM(C) 7, DILM(C) 9, DILM(C) 12, DILM(C) 15, XTC E(C) , XTC E(C) , XTC E(C) , XTC E (C) 015 series controllers have a short-circuit rating of 100KA at 600 Vac max, when used in conjunction with type C396 overload relay, when protected by Class J fuses having an interrupting rating not less than 100kA rms symmetrical amperes at 600V sized not greater than the current values of the table below: DILM(C) 7, XTC E(C) DILM(C) 9, XTC E(C) DILM(C) 12, XTC E(C) DILM(C) 15, XTC E(C) 015 Max Class J Non- Time Delay Fuse 20A 20A 45A 60A Contactors; Type DILM(F)(C) 40, XTCE(C)040, DILM(F)(C) 50, XTCE(C)050, DILM(F)(C) 65, XTCE(C) 065, DILM(F)(C) 72; Reversing contactor prefix DIULM(C)40, DIULM(C)50, DIULM(C)65, DIULM(C)72; Operating coil 12 to 240Vdc and 24 to 240Vac, 50-60Hz; Max. rating 3ph.: 60hp at 600Vac; Max. rating 1ph.: 15hp at 240Vac; Max. rating DC: 20hp at 240Vdc General use: 88A max. at 600Vac, 80A at 600Vdc, ; Version DILMC provided with spring force connectors. Contactor with 4 poles catalogue number: DILMP63, DILMP80 and DILMP100. Special rating for DILM(F)(C) 40, XTCE(C)040, DILMP63, DILM(F)(C) 50, XTCE(C)050, DILMP80: Tungsten 74A, 600Vac 79A, 600V ac Resistance Air Heating: 79A, 600V ac Refrigeration Control: FLA 54A, 600V ac LRA 290A, 600V ac Special rating for DILM(F)(C) 65, XTCE(C)065, DILM(F)(C) 72, DILMP100:
4 Page 4 of 7 Tungsten 88A, 600Vac 88A, 600V ac Resistance Air Heating: 88A, 600V ac Refrigeration Control: FLA 45A, 600V ac LRA 270A, 600V ac Mechanical Interlock catalogue number DILM65-XMV. 1. These devices are open type, 3 poles contactors intended to connect motors directly across the line. 2. DILM(F)(C) 40, XTCE(C)040, DILM(F)(C) 50, XTCE(C)050, DILM(F)(C) 65, XTCE(C)065 series controllers have a short-circuit rating of 75KA at 480 V max, when protected by a thermo magnetic circuit breaker having an interrupting rating not less than 75kA rms symmetrical amperes at 480V sized not greater than 100 Amps. 3. DILM(F)(C) 40, XTCE(C)040, DILM(F)(C) 50, XTCE(C)050, DILM(F)(C) 65, XTCE(C)065 series controllers have a short-circuit rating of 100KA at 600 V max, when used in conjunction with type C396 overload relay, when protected by Class J fuses having an interrupting rating not less than 100kA rms symmetrical amperes at 600V sized not greater than the current values of the table below: Max Class J Non-Time Delay Fuse DILM(F)(C) 40, XTCE(C)040 DILM(F)(C) 50, XTCE(C)050 DILM(F)(C) 65, XTCE(C) A 200A 250A Magnetic Motor Controllers Cat. Nos. DILM(F)(C)80-, XTCE(C)080, DILM(F) (C)95-, XTCE(C)095, DILM(F) (C)115-, XTCE(C)115, DILM(F) (C)150, XTCE(C)150 and DILM(F) (C)170-; Reversing contactors prefix DIULM(C)80-, DIULM(C)95-, DIULM(C)115-, DIULM(C)150- ; followed by 10 or -01; Operating coil 24 to 240Vdc and 24 to 600Vac, 50-60Hz; Max hp ratings 3ph, 600v-125hp; 1ph, 240v-30hp; Max. DC rating: 30hp at 240Vdc. Version DILMC provided with spring force connectors. Contactor with 4 poles catalogue number DILMP125, DILMP160 and DILMP200 followed by -10 or -01 Mechanical Interlock catalogue number DILM150-XMV Terminal assembly catalogue number: ZK-DILM or DILM150-XZK Special Rating for DILM(C) 80, XTCE(C)080, DILMP 125 General use: 125A at 600Vac, 125A at 600Vdc Definite purpose: FLA=141A, 480Vac, 50/60Hz; LRA=846A, 480Vac FLA=95A, 600Vac, 50/60Hz; LRA=570A, 600Vac Resistance Air Heating: 110A, 600Vac Refrigeration Control: FLA: 90A, 480Vac; 70A, 600Vac; LRA: 540A, 480Vac; 420A, 600Vac Tungsten: Elevator control: 60hp at 600Vac Special Rating for DILM(C)95, XTCE(C)095, DILMP160 General use 125A at 600Vac, 125A at 600Vdc Definite purpose: FLA=141A, 480Vac, 50/60Hz; LRA=846A, 480Vac FLA=95A, 600Vac, 50/60Hz; LRA=570A, 600Vac Resistance Air Heating: 110A, 600Vac Refrigeration Control: FLA: 90A, 480Vac; 70A, 600Vac; LRA: 540A, 480Vac; 420A, 600Vac Tungsten: Elevator control: 75hp at 600Vac Special Rating for DILM(C)115, XTCE(C)115, DILM(C)150, XTCE(C)150, DILM(C)170, DILMP200 General use for DILM(C )115 XTCE(C)115 : 180A, 600Vac; 180A, 250Vdc General use for DILM(C)150, DILM(C)170, DILMP200: 225A, 600Vac; 180A, 250Vdc Definite purpose: FLA=200A, 480Vac, 50/60Hz; LRA=1200A, 480Vac FLA=130A, 600Vac, 50/60Hz; LRA=780A, 600Vac 160A, 600Vac
5 Page 5 of 7 Resistance Air Heating: Refrigeration Control: Tungsten: Elevator control: 160A, 600Vac FLA: 90A, 600Vac; LRA: 540A, 600Vac 160A, 600Vac 100hp at 600Vac 1. These devices are open type, 3 poles contactors intended to connect motors directly across the line. They are provided with an auxiliary contact normally opened (NO) or normally closed (NC) rated A600, P DILM(F)(C)80-, XTCE(C)080, DILM(F) (C)95-, XTCE(C)095, DILM(F) (C)115-, XTCE(C)115, DILM(F) (C)150, XTCE(C)150 series controllers have a short-circuit rating of 65KA at 480 Vac max, when protected by a thermo magnetic circuit breaker having an interrupting rating not less than 65kA rms symmetrical amperes at 480V sized not greater than 250 Amps. 3. DILM(F)(C)80-, XTCE(C)080, DILM(F) (C)95-, XTCE(C)095, DILM(F) (C)115-, XTCE(C)115, DILM(F) (C)150, XTCE(C)150 series controllers have a short-circuit rating of 100KA at 600 Vac max, when used in conjunction with type C396 overload relay, when protected by Class J fuses having an interrupting rating not less than 100kA rms symmetrical amperes at 600V sized not greater than the current values of the table below: DILM(C) 80, XTC E(C) 080 DILM(C) 95, XTC E(C) 095 DILM(C) 115, XTC E(C) 115 DILM(C) 150, XTC E(C) 150 Max Class J Non-Time Delay Fuse 300A 350A 450A 600A Contactors; Type DILM, may be followed by C, followed by 185, 225, 250, 300A, may be followed by S; 3 poles; Open type; Operating coil 24 to 500Vac/dc; 600Vac max.; 350A max.; 300HP max.; FLA: 300A max. at 600Vac; FLA: 360A max. at 480Vac; Version DILMC provided with spring force connectors. 1. These devices are open type, 3-pole contactors intended to connect motors directly across-the-line. 2. The devices are identical in construction only the ratings are different. 3. Standard short-circuit rating: 18kA, 600V (when protected with 700A Class L fuse or 600A circuit breaker) 65kA 480V (when protected with 250A circuit breaker) AC Across-the-Line magnetic Motor Starters, reversing and non-reversing, incorporating manual motor controller PKZM0, designated Cat. No. MSC-, followed by D or R-,followed by 0.25, -0.4, -0.63, -1.0, -1.6, -2.5, -4.0, -6.3, -10, -12, -16, 25, 32 followed by M7, M9, M12, M15, M17, M25 and M32, may be followed by SOND 516. Direct Starter Set PKZM4-XD M65. PKZM0-XD M32, PKZM0-XR M12, PKZM0-XS M32. AC Across the line Motor Controllers, Cat. No. MSC-, followed by D or R-, followed by 0.25, 0.4, -0.63, -1.0, -1.6, -2.5, -4.0, 6.3, -10, -12, -16, -25, -32 followed by M7, M9, M12, M15, M17, M25 and M32, followed by (230V 50Hz) or (24VDC), followed by /BBA. Combination Motor Controllers, type F, Model nos. PKE65 may followed by /AK, followed by /XTU (W) followed by 32 or 65, followed by SP and magnetic contactors DILM (17, 25, 40, 50, 72). Cat. No. XTPE followed by 032D or 065D followed by CSSP and magnetic contactors XTCE(C) 017, 025, 040, 050, 072. PKE65-32-SP + DILM (17, 25): Rated: 32A at 600Vac; 25HP max. At 600Vac max, 3 phases; 3HP max at 240Vac, 1 phase; 25kA, 600V (wyes)/347vac; 65kA, 480V (wyes)/277vac
6 Page 6 of 7 PKE65-32-SP + DILM (17, 25): Rated: 32A at 600Vac; 25HP max. At 600Vac max, 3 phases; 3HP max at 240Vac, 1 phase; 25kA, 600V (wyes)/347vac; 65kA, 480V (wyes)/277vac. PKE65-65-SP + DILM (40, 50, and 72): Rated: 58A at 600Vac; 40HP max. At 600vac max, 3 phases; 10HP max at 240Vac, 1 phase; 65kA, 480V (wyes)/277vac. Note: 1. The combination motor controller can be provided with already certified auxiliary switches. 2. Type designation XTPE is an alternate type designation for PKE65- Magnetic Contactors vacuum contact chamber, Types DILM 580, DILM 650, DILM 750, DILM 820, DILM 1000, DILM Suppressor protective units DILM(H) - - XSM Coil V ac/dc, V ac/dc, 24-48V dc and V ac/dc. Ratings: DILM General Use 630A, 600V ac; Short Circuit Withstand Rating 85kA, R.M.S. Symmetrical, 600V DILM General Use 700A, 600V ac; Short Circuit Withstand Rating 85kA, R.M.S. Symmetrical, 600V DILM General Use 800A, 600V ac; Short Circuit Withstand Rating 85kA, R.M.S. Symmetrical 600V DILM
7 Page 7 of 7 General Use 850A, 600V ac; Short Circuit Withstand Rating 85kA, R.M.S. Symmetrical 600V (Standard fault). DILM General Use 1000A, 600V ac, Max FLC 1000A, Max LRA 6000A Short Circuit Withstand Rating 85kA, R.M.S. Symmetrical 600V (Standard fault) DILM General Use 1600A, 600V ac, Max. FLA 1600A Short Circuit Withstand Rating 85kA, R.M.S. Symmetrical 600V (Standard fault) Note: These devices are open type, 3-pole contactors intended to connect motors directly across-the-line. These contactors are vacuum contactors. Contactors, Type DILH 1400, DILH 2000, DILH 2200, DILH2600, 3 pole, open type, for Air Heating and general purpose applications DILH1400: 1400A, 600V ac, DILH2000: 2000A, 600V ac and DILMH2200: 2200A, 600V ac; DILH2600, 2600A, 600Vac. Coil rated V AC/DC, V, AC/DC, V ac/dc, 24-48V dc, Vacuum contactor construction. With the following options: Suppressor protective units DILH - - XSM and Voltage peak limitation unit Sond715 for DILH The DILH 1400 has been tested for operations in endurance for 600V ac, 1400A, resistive. 2. The DILH 2000 has been tested for operations in endurance for 600V ac, 2000A, resistive. 3. The DILH2200 has been tested for operations in endurance for 600V ac, 2200A resistive. 4. The DILH 2600 has been tested for operations in endurance for 600vac, 2600A, resistive. 5. The DILH 1400, DILH 2000, DILH2200, DILH2600 may be marked "INDUSTRIAL HEATING CONTROL".
Cert.Record No _0_000, Class No , DQD No 557 Rev SUPPLEMENTARY PROTECTORS COMPONENT ACCEPTANCE PROGRAM
Seite 1 von 6 ACCEPTANCE RECORD File No: Class No: 016186_0_000 321530 SUPPLEMENTARY PROTECTORS COMPONENT ACCEPTANCE PROGRAM SUBMITTOR 4544043 E-T-A Circuit Breakers Limited 100 Leek Cr, Unit 11 Richmond
More informationLarge Frame IEC Contactors
Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1 Changing Applications for Contactors There are fewer and fewer traditional large motor starting
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationAllen-Bradley Bulletin 100 Contactors
Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression
More informationTable 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors.
IEC Power Control Devices Training Manual XT Training Module New Information March 08 Contents Description Page Overview..................... Contactors................... Overload Relays (Bimetal).......
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationXT IEC Power Control Contactors, Starters and Overload Relays
May 00 Product Family Overview 9 Contents Features and Benefits Description Page Contactors and Starters Catalog Number Selection................. Non-reversing Contactors.... Reversing Contactors........
More informationSiemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY
Issued to: Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that Auxiliary Devices representative samples of 3UF70 followed by 0 or 1 followed by 0
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: This is to certify that representative samples of SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY MOTOR CONTROLLERS, MANUAL (See following page for additional information.)
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More information.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical
Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor
More informationWMS SUPPLEMENTARY PROTECTORS
WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077
More information3RA13, 3RA14 Contactor Assemblies
RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that representative samples of Motor Controllers, Magnetic (See following pages for additional
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationMiniature Circuit Breakers and Supplementary Protectors. Contents
. Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationUL 489 DIN rail branch circuit breakers
UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product
More informationGo to:
System PKZ 0 ectors 08/019 Clip plate Standard version Short version C-PKZ0 072900 C-PKZ0-K 206740 One of the clip plates is always necessary when combining a PKZM0 manual motor prr and a S(E)00 magnetic
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More informationFile E Project 00ME December 18, 2000 REPORT COMBINATION CONTROLLERS. Siemens AG Amberg, Germany
File E156943 Project 00ME17885 December 18, 2000 REPORT on COMBINATION CONTROLLERS Siemens AG Amberg, Germany Copyright 2000 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationUL 489 Cable-In / Cable-Out Branch Circuit Breaker
Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More information1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers
.2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationThe simplicity of it! Tool-less plug connection without tools!
The simplicity of it! Tool-less plug connection without tools! Using the new xstart motor-starter combinations it is possible to create the best solutions from standard products even more easily and efficiently.
More information10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category Features Characteristics
More information3 Pole Contactors with AC operating coils
1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to
More informationK-Line Mini - Contactors, Overload Relays and Accessories
K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information...............................................
More informationMini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors
More information1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD
Molded Case Circuit Section Tri-Break Line Integrally Fused Thermal Magnetic Circuit Integrally Fused Magnetic Circuit Integrally Fused Molded Case Switches These breakers are available in three types.
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More informationECNR/ECSR Class RK5 Dual-Element Time-Delay Fuses. Catalog Number ECNR (1-600A) 250Vac or Less Catalog Number ECSR (1-600A) 600Vac or Less
Catalog Number ECNR ( - 600A) 250Vac or Less Catalog Number ( - 600A) 600Vac or Less Amp Ratings ECNR 8 25 70 50 400 2 9 30 75 75 450 3 35 80 200 500 4 2 40 90 225 600 5 5 45 250 6 7.5 50 300 7 20 60 25
More informationIEC Contactors. Auxiliary Contact Blocks GENERAL
IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount
More informationAllen-Bradley Drives
Overview/Product Selection Bulletin IEC Industrial Safety Relay Positively Guided/Mechanically Linked as Per IEC 947-5-1 Annex L Third Party Certification By SUVA Red Cover and Mechanically Linked Contact
More informationCS7 Industrial Control Relays
CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries
More informationContactors and Contactor Assemblies
RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.
More informationJK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A
POWER DISTRIBUTION JK Series Solid State Starters Medium Voltage 200-400-600-720A SOLID STATE STARTER JKSSS4+ Series The JKSSS Series of motor starter is the result of extensive research and development.
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationSelection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationAPL/UPL, 205/295 Series Magnetic Circuit Protectors
APL/UPL, 205/295 APL/UPL, 205/295 Series Magnetic Circuit Protectors Introduction 68 Single & Multi-Pole 69 Barriers 7 Configurations 72 Operating Characteristics 74 Delay Curves 75 Specifications 80 Decision
More informationEasyConnect SmartWire
EasyConnect SmartWire Seite - 1 Darwin Evolution in panel building Seite - 2 Darwin Control Drives easyconnect Motor starter MCCB Command and indication Seite - 3 Less wiring by moving the I/O to the contactor
More informationBNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS
BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS Safety Controller Suitable for use with Coded-Magnet Sensor Part Numbers below BNS250... BNS33... BNS303...
More informationMonitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview
Siemens AG 2010 Overview Benefits Can be used without auxiliary voltage in any network from 160 to 600 V AC worldwide thanks to wide voltage range Variably adjustable to overvoltage, undervoltage or range
More informationMotor Controllers AC Semiconductor Motor Controller Type RSHR MIDI
otor Controllers AC Semiconductor otor Controller Type RSHR IDI Soft starting and stopping of 3-phase induction squirrel cage motors 2-phase control with integral bypassing of semiconductors Low inrush
More informationProduct Guide. UL 489 DIN rail miniature circuit breakers
Product Guide UL 489 DIN rail miniature circuit breakers UL 489 DIN rail miniature circuit breakers Product Overview................................................ 2 Product Selection WMZT 10 kaic at
More information9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc.
Chapter 2 MOTOR SYMBOLS 1 Symbols are used to represent the different components of a motor control system. Symbols sometimes look nothing like the real thing, so we have to learn what the symbols mean.
More informationFUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC
Fuse protection The solution for > Live maintenance of speed drives supplied by a common DC bus > Live maintenance of PV inverters connected in parallel on a same circuit fuser-lm_2_a Strong points > Compact
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT
More information9926 Series Branch Rated Circuit Breakers AC Version
Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More informationTechnical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n
Safety module CS AT 0 Module for emergency stops, end position monitoring for movable guards with delayed contacts at the opening of the input channels, semiconductor outputs (e.g. light barriers and magnetic
More informationApplying branch circuit breakers and supplementary protectors in North America
Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationMagnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158
Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70
More informationTechnical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):
Safety module CS AR-91, according to EN 81 Safety modules for the lift automatic floor levelling operation according to EN 81 Main functions For safety applications up to SIL 3 / PL e Choice between automatic
More informationCrane Control Contactors and Relays
October 8 DC Relays Type KC Heavy-Duty Mill 75 Contact Conversion The fully visible contacts have NEMA ICS--5 heavy-duty interrupting ratings and are easily converted in the field using just a screwdriver
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationSafe monitoring relays
monitor for safe standstill monitoring Approvals Block diagram Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous LED indicator
More informationIPS INTELLIGENT PUMP STARTER
IPS INTELLIGENT PUMP STARTER The IPS Intelligent Pump Starter features SMARTSTART motor protection, integrated electronic pump protection overload, and power metering and data logging options. Ø & Ø, 0/60
More informationTechnical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit
Safety module CS DM-01 Technical data Housing PA 6.6 polyamide housing, self-extinguishing, V0 acc. to UL 94 Protection degree IP40 (housing), IP20 (terminal strip) Dimensions see page 283, design A Two-hand
More informationAllen-Bradley 700-K40E-DJ
Bulletin Overview/Product Selection Bulletin Miniature Control Relays IEC compact industrial relay IPX Finger Protection Bifurcated contacts for low-level signals Optional integrated coil protection diode
More informationTable of Specifications
Table of Specifications Midi-Contactors 3-Pole Magnetic Contactors Terminal type CC9 CC12 CC18 CC22 CC32 CC40 Screw Only Screw Only GUA1, GUA2, GUA4 GUA-1 GUA-2, GUA-4 GUA-1 GUA-2, GUA-4 GT Type Thermal
More informationSMARTSTART MOTOR STARTERS
SMARTSTART MOTOR STARTERS MCG WWW.MCG-USA.COM 1 AT A GLANCE Covers all line voltages from 200-600V AC, single or three phase Transformer supplies a 24V AC coil voltage, no matter the line voltage 12V AC/DC
More informationCERTIFICATE OF COMPLIANCE
Issued to: SIEMENS AG LOW VOLTAGE SIEMENSSTRASSE 10 93055 REGENSBURG GERMANY This is to certify that representative samples of CIRCUIT BREAKERS, MOLDED CASE AND CIRCUIT- BREAKER ENCLOSURES See Addendum
More informationNon-Fusible Disconnect Switches
UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of
More informationControls Enclosed Non-Combination Starters - PESW Series
NEMA 4/4X Non Metallic Enclosure Product Features WEG offers non-reversing and non-combination NEMA-4X magnetic starter up to 75HP at 460V. Featuring components that meet IEC design standards and UL horsepower
More informationCFW-09HD LINE DC LINK POWER SUPPLY
CFW-09HD LINE DC LINK POWER SUPPLY CFW-09HD Line Addendum to the CFW-09 Manual Addendum to the CFW-09 Manual CFW-09HD Line I. GENERAL INFORMATION This addendum has information about the CFW-09HD line
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationSeries CA7 Contactors
Series Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor line.
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationClick 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry.
Click 'n' Go: SIRIUS Modular System SIRIUS Highly flexible system-based switching, protecting and starting. Answers for industry. s Everything for the electrical cabinet: SIRIUS Modular System. Contents
More informationJockey Pump Controllers
BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single
More informationApplying branch circuit breakers and supplementary protectors in North America
Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North
More informationCERTIFICATE OF COMPLIANCE
Issued to: SIEMENS AG I IA CE CP R&D-VI 4, WERNER-VON-SIEMENS- STRASSE 48, 92220 AMBERG GERMANY This is to certify that representative samples of SWITCHES, INDUSTRIAL CONTROL See next page for models Have
More informationMotor Controllers AC Semiconductor Motor Controller Type RSHR MIDI
otor Controllers AC Semiconductor otor Controller Type RSHR IDI Soft starting and stopping of 3-phase induction squirrel cage motors 2-phase control with integral bypassing of semiconductors Low inrush
More informationMagnetically Actuated Safety Interlock Switches
Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,
More informationATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink
Characteristics variable speed drive ATV12-2.2kW - 3hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationProducts :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers
Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Miniature Hydraulic/Magnetic Circuit Breaker M-Series M-Series PDF elibrary The M-Series miniature hydraulic/magnetic circuit breakers
More information1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD
Molded Case Circuit Section Tri-Break Line Integrally Fused Thermal Magnetic Circuit Integrally Fused Magnetic Circuit Integrally Fused Molded Case Switches These breakers are available in three types.
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options
More informationIEC Power Control Contactors and Contactor Assemblies
IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,
More informationCS8 Industrial Control Relays
CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum
More informationProduct Guide. UL 1077 DIN Rail Supplementary Protectors
Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................
More informationSicherheit, auf die Sie sich verlassen können
Explosion protected distributions CROUSE-HINDS SERIES Sicherheit, auf die Sie sich verlassen können GHG 6277 E-Series MCCB 63-160 A Ex-d built-in components for Zone 1 and 2 (IEC) www.crouse-hinds.de EATON
More informationNC2 Contactor, 115~630A. 1. General. 2. Type Designation. 3. Terminal Connection. Cabling(Cu) Cable 2. Tightening torque (N m) Screw size
R C US LISTED EU Germany Czech Ukrain South Africa USA NC Contactor, 5~30A. General. Certificates: CE, VDE, ESC, UKRTEST, RCC, UL.. Electric ratings; AC50/0Hz, up to 000V, up to 30A;.3 Application: remote
More information209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards
The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker
More informationMOTOR & CIRCUIT PROTECTION
2 MOTOR & CIRCUIT PROTECTION Motor Protection Circuit Breakers p2-1 Motor Protection Relays p2-13 Thermistor Protection Relay p2-18 Fuse Holders p2-20 Miniature Circuit Breakers p2-23 Residual Current
More informationContactors and Contactor Assemblies
Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.4 Contents Description Page Product Description............................. 677 Standards and Certifications...................... 677 Product Selection..............................
More informationTeSys contactors From 115 to 2750 A
Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,
More informationQuantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III
Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North
More informationonlinecomponents.com
ccessories Field Installable Top (Front) Mount uxiliary Contact Blocks ➊ Contact Block NO NC Top mount auxiliary contact blocks snap-on to the top (front) of any contactor 4-pole auxiliary 2-pole auxiliary
More informationRevolutionizing control wiring
SmartWire-DT Panel Wiring Solutions Revolutionizing control wiring 797-6925 Fax: (215) 221-1201 www.royalelectric.com SmartWire-DT Changing the way panels are wired. Reduce cost throughout the value chain.
More information