1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

Size: px
Start display at page:

Download "1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD"

Transcription

1 Molded Case Circuit Section Tri-Break Line Integrally Fused Thermal Magnetic Circuit Integrally Fused Magnetic Circuit Integrally Fused Molded Case Switches These breakers are available in three types. Type TB1 (15- amperes) product numbers include frame, trip, line and load lugs, and current limiters all factory assembled. TB6 (00 to amperes) and TB8 ( to 800 amperes) include frame, trip and limiters, factory assembled, but do not include line or load lugs. If line and load lugs are required, order separately. Unless otherwise noted, TB1, TB6, and TB8 breaker components are UL listed in File E 46. Fused molded case switches are UL listed in File E Mag-Break Line Magnetic only circuit breakers (motor circuit protectors) These breakers are available only with noninterchangeable adjustable magnetic trip, in frame Types E, F, J, K, and Tri-Break. All breakers are shipped factory assembled, complete with Cu/Al line and load lugs. All magnetic only circuit breakers and limiters are UL Component Recognized in Files E 1159 and E 6690, respectively, unless otherwise noted. Spectra RMS Circuit Determine the required breaker frame, IC rating, and load requirements. Select frame, trip unit (rating plug), and lug, if required, product numbers from the tables on pages -46 to -54. For Spectra breakers with MicroVersaTrip Plus or MicroVersaTrip PM Trip Units refer to pages -57 through -. Select field-mounted internal accessory product numbers, if required, on pages -70 and -71. Select fieldmounted external accessory product numbers, if required, on pages -97 through -107 and pages -66 to -69 for Spectra breakers with MicroVersaTrip Plus or MicroVersaTrip PM Trip Units. Order as separate items. Mag-Break Motor Circuit Protectors Determine the required frame and ampere requirements. Select frame, trip unit (rating plug), and lug, if required, product numbers from the table on pages -7 through -75. Select accessories as noted above for circuit breakers. The same accessories are used with both circuit breakers and motor circuit protectors. Order as separate items. Molded Case Switches Determine the required frame and ampere requirements. Select frame and lug, if required, product numbers from the table on page -7. Rating plugs are not used. Select accessories as noted above for circuit breakers. Internal accessories do not require dummy trips. The same accessories are used with both circuit breakers and molded case switches. Order as separate items. Unless otherwise noted, all circuit breakers are UL listed in File E Molded case switches are UL listed in File E Field-Installable Internal Accessories are UL listed in File E 575. Distribution Cable Accessories for MicroVersaTrip Plus Trip Units and MicroVersaTrip PM Trip Units are UL listed in File E 575. Accessories Order accessories from the appropriate table: Thermal Magnetic Circuit, Magnetic Circuit, and Molded Case Switches 1 pages -9 to -45 and -97 to Spectra RMS pages -70 to -71 and -97 to Spectra RMS with MicroVersaTrip Plus Trip Units or MicroVersaTrip PM Trip Unitspages -66 to -71, and -96 to Installation of accessories in molded case switches requires dummy trip; see page -45 for information. Dummy trip not required for Tri-Break or Q-Line molded case switches. Molded Case Circuit Breaker and Switch Terminal Configuration Code Order standard Cu/Al lugs by using suffix codes presented. Order lugs separately if special lugs are required. For optional lugs, see pages -101 and -10. Breaker/Switch Type TQD/TJD Molded Case, Thermal Magnetic Molded Case Switch Spectra RMS Mine Duty Mag-Break Blank WL XL X LL Suffix Line Lugs Line Lugs Order Lugs Separately Order Lugs Separately Publications and Reference: See Section for a -

2 Molded Case Circuit Section Quick Reference Guide 15-A Circuit Electric Trip Spectra RMS Ratings do not apply to molded case switches. The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker of the type given in the left-hand column may be applied at the given circuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values of circuit voltage provided the available fault current at the load terminals of the breaker does not exceed the value in the table for the higher value of voltage. SE 1 Spectra RMS Circuit UL/CSA Ratings Solid-State with Interchangeable Trip Unit (Rating Plug) Circuit UL Listed Interrupting RatingkA Dimensions Inches (mm) Approx. Ship Breaker Ampere No. Maximum Wt./Std. Type Rating Poles Vac 40 Vac 480 Vac Vac H W D A B C E Pack SE1 Current Limiting (UL File No. E-1159; CSA LR 40) SED 480 SEH SEP 00 5 SF- Current Limiting (UL File No. E-1159; CSA LR 40) SFH SFL SFP 00 5 SG Current Limiting (UL File No. E-1159; CSA LR 40) 1, SGH1, SGD SGH4 5 5 SGH6-5 5 SGL SGP (56) (0) (97) (11) (84) () (0) 5 5 SGL SGP4 00 SGL6 - SGP6 00 SK (UL File No. E-1159; CSA LR 40) 1, SKH8 SKL8 SKP8 SKH1 SKL1 SKP (94) 8.5 (10) 5. (0) 8.56 (17) 5.69 (5) 1.8 (5).6 () UL listed as HACR (heating, air conditioning and refrigeration). Not current-limiting circuit breaker. Includes MicroVersaTrip Plus Trip Units and MicroVersaTrip PM Trip Units. Publications and Reference: See Section for a 6.1 (0) 10.1 (57) 4.1 (105) 4.1 (105).8 (86).81 (97).41 (61).87 (98).47 (6).87 (98).69 ().69 ().7 () 1.19 (0) 4 MicroVersaTrip Plus Trip Units and MicroVersaTrip PM Trip Units only. 5 Add 1.76 inches (45 mm) to each end with lugs and lug cover installed. 6 Add 4.00 inches (101 mm) to upper end for SKP ( kaic-480v) lug cover. 5. lb/ lb/1 15. lb/ lb/1-7

3 Molded Case Circuit Section Quick Reference Guide 15-A Circuit Electric Trip Spectra RMS Ratings do not apply to molded case switches IEC/JIS Ratings Solid-State with Interchangeable Trip Unit (Rating Plug) Japanese Industry Standard IEC 947- Interruption Capacity ka Interruption Capacity ka Circuit 0-40 Vac Vac 0 Vac 690 Vac Vac Breaker Ampere No. Type Rating Poles I cu I cs I cu I cs I cu I cs I cu I cs SE1 Current Limiting, 15-A SED SEH SEP SE1 Current Limiting, 40-0A SED SEH SEP SF Current Limiting SFH SFL SFP SG Current Limiting SK SGH SGL SGP SGH SGL SGP SGH SGL SGP SKH8 SKL8 SKP8 SKH1 SKL1 SKP MicroVersaTrip Plus trip system only SE SF SG SK -8

4 Molded Case Circuit Section Page Updated 11 / A Circuit Electronic Trip Spectra RMS SE1 Line Circuit Product Number Structure S E D A 4 A T 000 Frame Rating Interruption Continuous Voltage Trip Trip Sensor Family (Amperes) Rating (480V) Load Rating Poles Rating Unit Function (Max Amps) S = Spectra E = 1 D = ka A = Standard = poles 4 = 480V A = RMS1 T = LSI H = 5 ka = poles 6 = V 0060 L = ka 0 P = ka 01 1 Adjustable Instantaneous with Tracking Short Time (Long Time established via Interchangeable Rating Plugs). Note: This information is provided for interpreting product numbers (it should not be used to build product numbers). SE1 Line, Suitable for Reverse Feed, UL File E-1159, CSA LR 40 SED, SEH; -Pole, UL/CSA: 1A, 480 Vac Max., IEC 947-: 0A, 415 Vac Max. Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) Adj. Inst. ka 5kA Ampere Trip Range Amps Product List Price Current Product List Price Product List Price Product List Price Wire Rating Low High Number GO-15S Sensor Number GO-15S Number GO-15S Number GO-15S Range 15 4 SRPE0A15 $ SRPE0A0 $ SRPE0A5 $ SEDA4AT000 $.00 SEHA4AT000 $ SRPE0A0 $ SRPE60A40 $ SRPE60A $ SEDA4AT0060 $.00 SEHA4AT0060 $ SRPE60A60 $ SRPEA70 $ SRPEA80 $ SRPEA90 $ SEDA4AT0 $1.00 SEHA4AT0 $ SRPEA $ SRPE1A110 $ SRPE1A15 $ SEDA4AT01 $87.00 SEHA4AT01 $ SRPE1A1 $ /0 Cu TCAL $.00 1-/0 Al SE1 Line, Suitable for Reverse Feed, UL File E-1159, CSA LR 40, SEP ; -Pole, UL/CSA: 1A, 480 Vac Max., IEC 947-: 0A, 415 Vac Max. Rating Plug Frame Terminal Lugs for Front Connection (Cu/Al) Adj. Inst. ka ka Ampere Trip Range Amps Product List Price Current Product List Price Product List Price Product List Price Wire Rating Low High Number GO-15S Sensor Number GO-15S Number GO-15S Number GO-15S Range 15 4 SRPE0A15 $ SRPE0A0 $ SRPE0A5 $ A4AT000 $ SEPA4AT000 $ SRPE0A0 $ SRPE60A40 $ SRPE60A $ A4AT0060 $ SEPA4AT0060 $ SRPE60A60 $ TCAL $.00 1-/0 Cu SRPEA70 $ /0 Al SRPEA80 $ SRPEA90 $ A4AT0 $ SEPA4AT0 $ SRPEA $ SRPE1A110 $ SRPE1A15 $ A4AT01 $08.00 SEPA4AT01 $ SRPE1A1 $106.00, SEP UL current limiting. Note: All Spectra breakers UL listed as HACR type. All Spectra breakers marked CE. -46

5 Molded Case Circuit Motor Circuit Protectors -1A Mag-Break Motor Circuit Protectors Current Limiting, UL Component Recognized 1 Section Features Suitable for Reverse Feed UL Recognized File E-1159 CSA Certified LR 40 IEC Vac Max. SE 1 0 Ampere Max. SF Ampere Max. SG 60 Ampere Max. SK 1 Ampere Max. UL Current Limiting High Interrupting Capacity Spectra RMS Motor Circuit ProtectorsSE1 Line -Pole Terminal Lugs for Rating Plug Frame Front Connection (Cu/Al) Adjustable Instantaneous Vac Vac Ampere Trip Ampere Range Product List Price Current Product List Price Product List Price Product List Price Wire Rating Low High Number GO-15S Sensor Number GO-1S Number GO-1S Number GO-15S Range 11 9 SRPE7A $ SRPE7A7 $ A6AI0007 $.00 SEPA6AI0007 $66.00 TCAL $ SRPE0A15 $ SRPE0A0 $ SRPE0A5 $ A6AI000 $.00 SEPA6AI000 $66.00 TCAL $ SRPE0A0 $ /0 Cu SRPE60A40 $ SRPE60A $ A6AI0060 $ SEPA6AI0060 $8.00 TCAL $ SRPE60A60 $ /0 Al SRPEA70 $ SRPEA80 $ SRPEA90 $ A6AI0 $ SEPA6AI0 $94.00 TCAL $ SRPEA $ SRPE1A110 $ SRPE1A15 $ A6AI01 $ SEPA6AI01 $ TCAL $ SRPE1A1 $ Standard Capacity Mag-Break Motor Circuit ProtectorsAdjustable Magnetic Trip, Noninterchangeable Types TEC, TECL Complete Breaker (includes line and load lugs) Vac Vac Adjustable Trip Two-Pole, 480 Vac Three-Pole, Vac Add-on Three-Pole Limiter, Vac Ampere Ampere Range Product List Price Product List Price Product List Price Rating Low High Number GO-1 Number GO-1 Number GO TEC400 $.00 TEC $88.00 TECL $ TEC4007 $.00 TEC7 $88.00 TECL7 $ TEC4015 $.00 TEC6015 $88.00 TECL6015 $ TEC400 $.00 TEC $88.00 TECL $ TEC40 $77.00 TEC60 $ TECL60 $ TEC4 $41.00 TEC6 $ TECL6 $ TEC41 $ TEC61 $ TECL61 $ Per UL 489, interruption ratings are not printed on the product label (interruption ratings are established based on a tested combination of the motor circuit protector and a properly sized overload relay and contactor). AC only Two-pole furnished in three-pole case. Publications and Reference: See Section for a -7

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Section Tri-Break Line Integrally Fused Thermal Magnetic Circuit Integrally Fused Magnetic Circuit Integrally Fused Molded Case Switches These breakers are available in three types.

More information

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD Molded Case Circuit Section Tri-Break Line Integrally Fused Thermal Magnetic Circuit Integrally Fused Magnetic Circuit Integrally Fused Molded Case Switches These breakers are available in three types.

More information

Taxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V THERMAL MAGNETIC, COMMON TRIP

Taxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V THERMAL MAGNETIC, COMMON TRIP 3804 South Street 759647263, TX Nacogdoches Phone: 9365697941 Fax: 9365604685 Catalog Number Manufacturer Description Weight per unit Product Category Features Current Rating Interrupting Rating Poles

More information

Miniature Circuit Breakers and Supplementary Protectors. Contents

Miniature Circuit Breakers and Supplementary Protectors. Contents . Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.

More information

UL 489 DIN rail branch circuit breakers

UL 489 DIN rail branch circuit breakers UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................

More information

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

UL 489 Cable-In / Cable-Out Branch Circuit Breaker Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North

More information

WMS SUPPLEMENTARY PROTECTORS

WMS SUPPLEMENTARY PROTECTORS WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077

More information

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers .2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E LG Frame, Types NLGB, HLGB and LLGB. These are two and three pole circuit breakers with non-interchangeable thermal magnetic and electronic trip units. They are uncompensated 40 o C construction rated

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

MULTI 9 System Catalog

MULTI 9 System Catalog MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: This is to certify that representative samples of SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY MOTOR CONTROLLERS, MANUAL (See following page for additional information.)

More information

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer January 0 Vol.,Ref. 2-2 Product Line Overview January 0 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case Circuit s are designed to provide circuit protection for

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

Taxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V Molded case circuit breaker

Taxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V Molded case circuit breaker 4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96--468 GHB00 P 0A 77/4V Breaker Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating

More information

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Crane Control Contactors and Relays

Crane Control Contactors and Relays October 8 DC Relays Type KC Heavy-Duty Mill 75 Contact Conversion The fully visible contacts have NEMA ICS--5 heavy-duty interrupting ratings and are easily converted in the field using just a screwdriver

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

GE Energy Industrial Solutions. GE Overcurrent Device Instantaneous Selectivity Tables

GE Energy Industrial Solutions. GE Overcurrent Device Instantaneous Selectivity Tables GE Energy Industrial Solutions GE Overcurrent Device Instantaneous Selectivity Tables Contents Introduction...3 Selectivity with EntelliGuard TU and microentelliguard EntelliGuard TU Trip Units in ANSI

More information

Taxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V

Taxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V 4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96--468 Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating circuit breaker type dimensions interrupt

More information

Table 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors.

Table 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors. IEC Power Control Devices Training Manual XT Training Module New Information March 08 Contents Description Page Overview..................... Contactors................... Overload Relays (Bimetal).......

More information

Multi 9 System Catalog

Multi 9 System Catalog Multi 9 System Catalog Catalog 0860CT00 R07/4 04 Class 860 CONTENTS CONTENTS Description............................................. Page Description Page Introduction..................................................7

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery

More information

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP Bulletin Control Circuit and Load Protection Product Overview Bulletin -MC -MCGA, -MCEA -SP Type Branch Ground Fault Detection Features /V, V & Y/V rating A interrupt / in. per pole wide... A @ UL Circuit

More information

C 2 5 D N A A A

C 2 5 D N A A A Product Family Overview May 007 pplication Description These Cutler-Hammer ampere and horsepower rated devices from Eaton s electrical business are designed for service in applications such as Refrigeration,

More information

Cert.Record No _0_000, Class No , DQD No 557 Rev SUPPLEMENTARY PROTECTORS COMPONENT ACCEPTANCE PROGRAM

Cert.Record No _0_000, Class No , DQD No 557 Rev SUPPLEMENTARY PROTECTORS COMPONENT ACCEPTANCE PROGRAM Seite 1 von 6 ACCEPTANCE RECORD File No: Class No: 016186_0_000 321530 SUPPLEMENTARY PROTECTORS COMPONENT ACCEPTANCE PROGRAM SUBMITTOR 4544043 E-T-A Circuit Breakers Limited 100 Leek Cr, Unit 11 Richmond

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

Product Guide. UL 489 DIN rail miniature circuit breakers

Product Guide. UL 489 DIN rail miniature circuit breakers Product Guide UL 489 DIN rail miniature circuit breakers UL 489 DIN rail miniature circuit breakers Product Overview................................................ 2 Product Selection WMZT 10 kaic at

More information

Supplemental Protectors

Supplemental Protectors compact S200 Series Miniature circuit breakers S200, S200P, S200U, S200UP Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The S2 devices are

More information

IELR Rail-Mount Series Magnetic Circuit Protectors

IELR Rail-Mount Series Magnetic Circuit Protectors IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 0CT00R/0 0 CONTENTS Description..............................................Page Description.............................................

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers Easily replace electro-mechanical trip units with the latest electronic, digital trip unit technology Ensure

More information

Spectra RMS Circuit Breakers with microentelliguard Trip Units

Spectra RMS Circuit Breakers with microentelliguard Trip Units GE Energy Industrial Solutions Spectra RMS Circuit Breakers with microentelliguard Trip Units Greater system coordination, arc flash protection and reliability for new equipment and retrofit applications

More information

Control Circuit and Load Protection Products

Control Circuit and Load Protection Products Selection Guide Control Circuit and Load Protection Products Bulletin Numbers 188, 1489, 1492, 1692 Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

SACE Emax 2 Specification guide

SACE Emax 2 Specification guide SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

I-Line Panelboards. Innovative design, smart bus technology, and simple installation I-Line Panelboards Innovative design, smart bus technology, and simple installation TM Smart: designed for efficient installation Simple: Efficient Installation Process I-Line Breakers Main Lugs: Fixed-mounted

More information

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5

More information

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...

More information

ALLEN BRADLEY RELAY Bulletin 700-HF

ALLEN BRADLEY RELAY Bulletin 700-HF ALLEN BRADLEY RELAY Bulletin 700-HF Contact Rating DPDT, 3PDT, 4PDT Plug-in Quick Connect Solder Terminals Options: LED, Push-to-Test Operator DEMENSIONS: Bulletin 700-HF Relay (DPDT) Bulletin 700-HF (3PDT)

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

APL/UPL, 205/295 Series Magnetic Circuit Protectors

APL/UPL, 205/295 Series Magnetic Circuit Protectors APL/UPL, 205/295 APL/UPL, 205/295 Series Magnetic Circuit Protectors Introduction 68 Single & Multi-Pole 69 Barriers 7 Configurations 72 Operating Characteristics 74 Delay Curves 75 Specifications 80 Decision

More information

9926 Series Branch Rated Circuit Breakers AC Version

9926 Series Branch Rated Circuit Breakers AC Version Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering

More information

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers Easily replace electro-mechanical trip units with the latest electronic, digital trip unit technology Ensure

More information

Time Delay Values (E-Series)

Time Delay Values (E-Series) Time Delay Values (ESeries) AC Instantaneous 00 0 INSTANTANEOUS CURVE NO. 20 00 0 DC D.C. INSTANTANEOUS CURVE NO. 0 0. 0..0.0.00 200 300 400 500 700 800 900 0 200.00 200 300 400 500 700 800 900 0 200 Short

More information

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker

More information

CANADIAN CATALOG JANUARY SENTRICITY Loadcentres and Circuit Breakers Raising the standard in residential.

CANADIAN CATALOG JANUARY SENTRICITY Loadcentres and Circuit Breakers Raising the standard in residential. CANADIAN CATALOG JANUARY 208 Loadcentres and Circuit Breakers Raising the standard in residential. 2 S E N T R I C I T Y T M L O A D C E N T R E S A N D C I R C U I T B R E A K E R S - C A N A D I A N

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Application Techniques CENTERLINE 2100 Motor Control Centers

Application Techniques CENTERLINE 2100 Motor Control Centers POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2 The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results

More information

General Purpose Control Components Welcome to the Control Catalog!

General Purpose Control Components Welcome to the Control Catalog! Welcome to the Control Catalog! This new edition is your comprehensive guide to product selection and pricing for GE electrical control products. Our new format in this latest edition allows for maximum

More information

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158 Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70

More information

E-Series General Specifications

E-Series General Specifications -Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire

More information

IELR Series

IELR Series IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

MULTI 9 System Catalog

MULTI 9 System Catalog MULTI 9 System Catalog Class 80 CONTENTS Schneider Electric Brands Description Page SectionIntroduction... Section UL 89 Listed Circuit Breakers and UL 77 Recognized SupplementaryProtectors... SectionIEC097-RatedProtectionDevices...

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE Issued to: SIEMENS AG LOW VOLTAGE SIEMENSSTRASSE 10 93055 REGENSBURG GERMANY This is to certify that representative samples of CIRCUIT BREAKERS, MOLDED CASE AND CIRCUIT- BREAKER ENCLOSURES See Addendum

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225 A, 8 to 42

More information

Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series

Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Miniature Circuit Breakers

More information

Go to:

Go to: System PKZ 0 ectors 08/019 Clip plate Standard version Short version C-PKZ0 072900 C-PKZ0-K 206740 One of the clip plates is always necessary when combining a PKZM0 manual motor prr and a S(E)00 magnetic

More information

Circuit Breakers NEED

Circuit Breakers NEED Type BR NEED Product Description The primary function of a circuit breaker is to protect the wire from overheating (referred to as an overload) and fault currents (referred to as short circuits). Circuit

More information

Cert.Record No _C_000, Class No , DQD No 548 Rev

Cert.Record No _C_000, Class No , DQD No 548 Rev Page 1 of 7 CERTIFICATION RECORD The company named below has been authorized by CSA International to represent the products listed in this record as CSA Certified and to affix the CSA Mark to these products

More information

UL 489 or UL 1077 in control panels and equipment a quick guide

UL 489 or UL 1077 in control panels and equipment a quick guide UL 489 or UL 1077 in control panels and equipment a quick guide A common question that comes up with OEM machine builders and control panel builders is How do I know when to use UL 1077 or UL 489 breakers

More information

Product Guide. UL 1077 DIN Rail Supplementary Protectors

Product Guide. UL 1077 DIN Rail Supplementary Protectors Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................

More information

Allen-Bradley Bulletin 100 Contactors

Allen-Bradley Bulletin 100 Contactors Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression

More information

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400 Overcurrentswitch,10A,3p,C-Char,AC Partno. FAZ-C10/3 Articleno. 278869 CatalogNo. FAZ-C10/3 Similar to illustration Deliveryprogramme Product range FAZ Application Instantaneous release response current

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery

More information

3.7. Control Relays and Timers.

3.7. Control Relays and Timers. Control Relays and Timers.7 BF/BFD Series Fixed Contact Industrial Control Contents D15 Series Freedom 600V Multipole.......... BF/BFD Series Fixed Contact Industrial Control Product Selection.......................

More information

UL 508 A standard-compliant design of industrial control panel

UL 508 A standard-compliant design of industrial control panel UL 508 A standard-compliant design of industrial control panel Axel Jöhnke System Architecture Expert 14-15 SEPTEMBER 2011, MUNICH Agenda www.infoplc.net Origin and Comprehension Organizations Certificates

More information

3.7. Control Relays and Timers. Contents. BF/BFD Series Fixed Contact Industrial Control. Machine Tool Relays. Product Description

3.7. Control Relays and Timers. Contents. BF/BFD Series Fixed Contact Industrial Control. Machine Tool Relays. Product Description Control Relays and Timers.7 BF/BFD Series Fixed Contact Industrial Control Contents D15 Series Freedom 600V Multipole.......... BF/BFD Series Fixed Contact Industrial Control Product Selection.......................

More information

Controls Enclosed Non-Combination Starters - PESW Series

Controls Enclosed Non-Combination Starters - PESW Series NEMA 4/4X Non Metallic Enclosure Product Features WEG offers non-reversing and non-combination NEMA-4X magnetic starter up to 75HP at 460V. Featuring components that meet IEC design standards and UL horsepower

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.4 Contents Description Page Product Description............................. 677 Standards and Certifications...................... 677 Product Selection..............................

More information

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY Issued to: Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that Auxiliary Devices representative samples of 3UF70 followed by 0 or 1 followed by 0

More information

140M C 2 N A63 KN CC GJ

140M C 2 N A63 KN CC GJ Motor Circuit Protectors Product Overview/Catalog Number Explanation Product Line Overview C-Frame D-Frame F-Frame H-Frame J-Frame L-Frame N-Frame Max. Current I e A A A 00 A 0 A 00 A 00 A Current Rating

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

T4 250A, 600V Electronic and thermal magnetic trip units

T4 250A, 600V Electronic and thermal magnetic trip units Electronic and thermal magnetic trip units T3 H x W x D 8.07" x 4.13" x 4.07" General The T4 breaker is a 250 amp frame with either a microprocessor based over current protective trip system or a thermal

More information

C-Series. Circuit Breaker

C-Series. Circuit Breaker C-Series Circuit Breaker The C-Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available

More information