BNI IOL Z036 BNI IOL Z036

Size: px
Start display at page:

Download "BNI IOL Z036 BNI IOL Z036"

Transcription

1 BNI IOL801000Z036 BNI IOL802000Z036 Smart Light User s Guide

2 Content 1 Notes to the user About this guide Structure of the guide Typographical conventions 3 Enumerations 3 Actions 3 Syntax 3 Crossreferences Symbols Abbreviations 3 2 Safety Intended use General safety notes Meaning of the warnings 4 3 Getting Started Overview BNI IOL801000Z Overview BNI IOL802000Z Mechanical connection Electrical connection Function ground IOLink connection 7 Sensor Hub connection 7 Module versions Short description of the functionality Segment mode Level mode Runlight mode 11 4 IOLink Interface IOLink Data Process data / Output data 12 Bit definitions in segment mode Parameter data/ Request data 16 Mode 40hex 18 Number of segments 41hex 18 Level type 42hex 18 Level resolution 43hex 18 Level mode segment x color 44hex, 45hex, 46hex, 47hex, 48hex 18 Bit definition Segment x 18 Level mode limit xy, 49hex, 4Ahex, 4Bhex, 4Chex 19 Runlight mode, background color 4Dhex 20 Runlight mode, running color 4Ehex 20 Runlight mode, number of running segments 4Fhex 20 Supply monitoring 50hex 21 Brightness 51hex 21 Blinking frequency 52hex 22 Blinking mode 53hex Errors Events 22 5 Technical Data Dimensions Mechanical data Electrical data Operating conditions LED indicator 24 Status LED

3 Balluff / IOLink BNI IOL802000Z036 6 Appendix Product ordering code Order information 25 Included material

4 1 Notes to the user 1.1 About this guide This guide describes the Balluff BNI IOL80x000Z03x for the application as status light module. Hereby it is about an IOLink device which communicates by means of IOLink protocol with the superordinate IOLink master assembly. 1.2 Structure of the guide 1.3 Typographical conventions Enumerations Actions Syntax Crossreferences The guide is organized so that the sections build on one another. Section 2: Basic safety information. Section 3: The main steps for installing the device. Section 4: IOLink, parameter and process data for the device. Section 5: Technical data for the device. The following typographical conventions are used in this Guide. Enumerations are shown in list form with bullet points. Entry 1, Entry 2. Action instructions are indicated by a preceding triangle. The result of an action is indicated by an arrow. Action instruction 1. Ä Action result. Action instruction 2. Numbers: Decimal numbers are shown without additional indicators (e.g. 123), Hexadecimal numbers are shown with the additional indicator hex (e.g. 00 hex). Crossreferences indicate where additional information on the topic can be found (see Section 5 "Technical Data ). 1.4 Symbols Note! This symbol indicates a security notice which most be observed. 1.5 Abbreviations BNI DPP EMC FE IOL SPDU Note, tip This symbol indicates general notes. Balluff Networking Interface Direct Parameter Page Electromagnetic Compatibility Function Earth IOLink Service Protocol Data Unit 3

5 Balluff / IOLink BNI IOL80x000Z03x 2 Safety 2.1 Intended use This guide describes the Balluff BNI IOL80x000Z03x for the application as status light module. Hereby it is about an IOLink device which communicates by means of IOLink protocol with the superordinate IOLink master assembly. 2.2 General safety notes 2.3 Meaning of the warnings Installation and startup Installation and startup are to be performed only by trained specialists. Any damage resulting from unauthorized manipulation or improper use voids the manufacturer's guarantee and warranty. The device complies with EMC Class A. Such equipment may generate RF noise. The operator must take precautionary measures accordingly. The device must be powered only using an approved power supply (see section 5 Technical data ). Only approved cable may be used. Operation and testing The operator is responsible for observing local prevailing safety regulations. When defects and nonclearable faults in the device occur, take it out of service and secure against unauthorized use. Approved use is ensured only when the housing is fully installed. Note! The pictogram used with the word "Caution" warns of a possible hazardous situation affecting the health of persons or equipment damage. Ignoring these warnings can result in injury or equipment damage. Always observe the described measures for preventing this danger. 4

6 3 Getting Started 3.1 Overview BNI IOL Z Fig. 31: BNI IOL801000Z036 1 Cap 2 Segment 1 3 Segment 2 4 Segment 3 5 Socket 6 M12 connector 7 M18 thread for mounting 8 Status LED

7 Balluff / IOLink BNI IOL80x000Z03x 3 Getting Started 3.2 Overview BNI IOL Z Fig. 32: BNI IOL802000Z036 1 Cap 2 Segment 1 3 Segment 2 4 Segment 3 5 Segment 4 6 Segment 5 7 Socket 8 M12 connector 9 M18 thread for mounting 10 Status LED

8 3 Getting Started 3.3 Mechanical connection 3.4 Electrical connection 3.5 Function ground 3.6 IOLink connection Sensor Hub connection The BNI IOL80x000Z03x modules are attached by using an M18 nut. The BNI IOL80x000Z03x modules require no separate supply voltage connection. Power is provided through the IOLink interface by the host IOLink Master. Note! The FE connection from the housing to the machine must be lowimpedance and as short as possible. IOLink (M12, Acoded, male) Pin Function 1 Power supply controller, +24V 2 3 GND, reference potential 4 C/Q, IOLink Data transmission channel Connection protection ground to FE terminal, if present. Connect the incoming IOLink line to the Sensor Hub. Note, tip! A standard 3 wire sensor cable is used for connecting to the host IOLink master. FE terminal with a screw to connect protection ground Module versions Version BNI IOL801000Z036 Maximum 3 segment configurable signal light with level meter and runlight mode. BNI IOL802000Z036 Maximum 5 segment configurable signal light with level meter and runlight mode. 7

9 Balluff / IOLink BNI IOL80x000Z03x 3 Getting Started 3.7 Short description of the functionality The functionality of the Balluff status light module can be controlled through process data and SPDU registers. It has three main mode of functionality: Segment mode Level mode Runlight mode With the help of these three modus various warning and indication signals can be indicated. 3.8 Segment mode In the segment mode the module can be used as a standard status light, with configurable number of segments. Maximum five or three segments can be set, depending on the type of the Smartlight. The color of each segment can be selected form a color table, which has five predefined colors. To use the module as a standard status light, the Mode SPDU register must be set to segment mode. The number of the active segments must be set too. This can be done through number of segments SPDU register. Irrespectively of the selected number of segments, always all of the LEDs are used as a display element. The number of the segments can be set any number between 1 and the maximal number of the segments. The module has 20 or 12 LED (depending on the type of the Smartligth), which are equally distributed between the segments. (By BNI IOL802000Z03x, when three segments are set, oneone LEDs between the segments will be always switched off). The process data controls the color of each segment. The combinations of the predefined colors are not limited. In the segment mode, the segments can be set to blink too. Each segment has a control bit in process data, which determines the blinking of the corresponding segment. The blinking has two modus. Either normal blinking or flash mode can be selected. In normal blinking the LEDs are switched on and off periodically with a 50% duty cycle. In the flash mode, the LEDs are switched on and off quickly three times. The flash is repeated in every second. The type of the blinking can be set in SPDU register. The frequency of the normal blinking can be changed through an SPDU register. 3.9 Level mode In level mode the complete module works as one indicator element. In this case a level value can be displayed. The higher value the module becomes, the more LEDs will be switched on. This mode can be used as a level indicator, for example to indicate a fluid level in a tank. To use the signal light as a level meter, the Mode SPDU register must be set to Level mode. In this case all of the LEDs are working as one display element. The number of the LEDs switched on depends on the input level. In the level mode the input process data does not give the colors of the segment, but the level. The resolution of the input level can be selected from 8 bit up to 16 bit. In the level mode various parameters can be controlled through SPDU registers. These parameters should be set before the level mode is used. The level display can be selected to be bottomup or topdown. In the bottomup mode the level indicator increases from the bottom of the module. In the topdown mode the indicator increases from the top of the module. Although there are no real segments in the level mode, because the LEDs are controlled by the input level, the LEDs are divided into five virtual segments. BNI IOL801000Z03x module can be divided into 3 virtual segments, while the BNI IOL802000Z03x can be divided into 5 virtual segments. These virtual segments can have their own color. The color of these segments can be set through SPDU register (Level mode segment x color SPDU register). So it can be realized, that the level meter can have more colors (up to the maximum number of the segments). Some or all colors can be set as dominant color. This means, when the input level is high enough to switch on the next LED and this LED is in another virtual segment, the LEDs, which are under the actual LED, take over the color of the actual LED. In this case, as the input level increases, the color of the full LED bar can be changed. The following examples are valid for BNI IOL802000Z03x (Smartlight with 5 segments), the BNI IOL801000Z03x (Smartlight with 3 segments) is working similar, only the number of the virtual segments are different. The lower two segments are green, the middle two segments are yellow color and the upper segment is red in the examples. 8

10 3 Getting Started The LED bar at increasing input data and no color dominance. (The virtual segments can be seen on the left side.) Of course the segment 2 or 4 does not have to be the same color as segment 3 or 5. Seg. 1 Seg. 2 Seg. 3 Seg. 4 Seg

11 Balluff / IOLink BNI IOL80x000Z03x 3 Getting Started The LED bar at increasing input data, all the colors are dominant. Seg. 1 Seg. 2 Seg. 3 Seg. 4 Seg

12 3 Getting Started By default the 20 LED are divided into equal virtual segments. The height of the virtual segments can be modified too. There are four SPDU register (Level mode limit xy SPDU register), in which the limits of the virtual segments can be modified. For example: If the input level value is higher than the limit value of the 2. and 3. segment (level mode limit 23), the current LED will become the color of the Level mode segment 2 color. The LED bar at increasing input data, there is no color dominance. The Limits of the segments are modified, so they are not equally distributed. Of course segment 3, 4 and 5 could have different colors too. Seg. 1 Seg. 2 Seg. 3 Seg. 4 Seg Runlight mode In the runlight mode, the complete module displays a running light effect. To use the module as a runlight display, the Mode SPDU register must be set to runlight mode. In this case all of the LEDs are working as one runlight effect. The process data has no meaning because the runlight mode is controlled only by SPDU registers. Four registers set the functionality of the runlight. The color of the running LEDs and the background color can be selected in two SPDU register. The colors are the same as the colors in the segment mode. The number of the running segments can be set too. In runlight mode 1, 2 or 3 running segments can be selected, but only by the 5 segment version. Smartlight with 3 segment can have only one running segment. One segment contains 4 LED. The speed of the running segment can be selected too. The blinking frequency register controls the speed of the running segment in runlight mode. 11

13 Balluff / IOLink BNI IOL80x000Z03x 4 IOLink Interface 4.1 IOLink Data BNI IOL801000Z036 Data transmission rate COM2 (38,4 kbaud) Minimal cycle time 5 ms Process data lenght 2 Byte input IOLink Revision Frame typ 2.V 1 Process data cycle time* 5 ms 30 ms * by min. cycle time 4.2 Process data / Output data BNI IOL802000Z036 Data transmission rate COM2 (38,4 kbaud) Minimal cycle time 5 ms Process data lenght 3 Byte input IOLink Revision Frame typ 2.V 1 Process data cycle time* 5 ms 30 ms * by min. cycle time BNI IOL801000Z036, Segment Mode Byte 0 1 Bit Segment 2 blink Segment 2 color Segment 2 color Segment 2 color Segment 1 blink Segment 1 color 12 Segment 1 color Segment 1 color Segment 3 blink Segment 3 color Segment 3 color Segment 3 color

14 4 IOLink Interface Bit definitions in segment mode BNI IOL802000Z036, Segment Mode Byte 0 1 Bit Segment 2 blink Segment 2 color Segment 2 color Segment 2 color Byte 2 Segment 1 blink Segment 1 color 13 Segment 1 color Bit Bit 02 / = off 001 = green 010 = red 011 = yellow 100 = blue 101 = reserved 110 = reserved 111 = white Segment 5 blink Segment 5 color Segment 5 color Segment 1 color Segment 5 color Segment 4 blink Bit 3 / 7 Segment 4 color Segment 4 color Segment 4 color Segment 3 blink Segment 3 color Segment 3 color 0 segment does not blink 1 segment blinks according to the blink modus settings Segment 3 color

15 Balluff / IOLink BNI IOL80x000Z03x 4 IOLink Interface BNI IOL801000Z036, Level Mode Byte 0 1 Bit bit level value 10 bit level value bit level value 14 bit level value 16 bit level value Level value: 8, 10, 12, 14 or 16 bit value for level indicator. The resolution can be set in Level resolution SPDU register. The Level value is always left justified. BNI IOL802000Z036, Level Mode Byte 0 1 Bit Byte 2 8 bit level value 10 bit level value 12 bit level value 14 bit level value Bit bit level value Level value: 8, 10, 12, 14 or 16 bit value for level indicator. The resolution can be set in Level resolution SPDU register. The Level value is always left justified.

16 4 IOLink Interface BNI IOL801000Z036, Runlight Mode Byte 0 1 Bit BNI IOL802000Z036, Runlight Mode Byte Bit Byte 2 Bit In runlight mode the process data has no meanings, only SPDU registers are controlling the functionality.

17 Balluff / IOLink BNI IOL80x000Z03x 4 IOLink Interface 4.3 Parameter data/ Request data Identification Data DPP SPDU Object name Length Range Default Value Index Index Subindex 07hex 08hex 09hex 0Ahex 0Bhex Vendor ID Device ID Byte 3 Byte Read only 0378hex 050A02 hex 050A01hex 10hex 0 Vendor name 7 Byte BALLUFF 11hex 0 Vendor text 15 Byte 12hex 0 Product name 20 Byte 13hex 0 Product ID 7 Byte 14hex 0 Product text 21 Byte 16hex 0 17hex 0 Hardware Revision Firmware Revision 1 Byte 47 Byte 18hex 0 Application tag* 32 Byte * 32 Byte string adjustable by the user Read / Write BNI IOL801000Z036 BNI IOL802000Z036 BNI007F BNI0072 Smart Light 3 segment Smart Light 5 segment

18 4 IOLink Interface Parameter Data DPP SPDU Object name Length Range Default Index Index Subindex Value 40hex 0 Mode 1 Byte 0 hex 2 hex 0hex 41hex 0 Number of segments 1 Byte 1 hex 3 hex 1 hex 5 hex* 42hex 0 Level type 1 Byte 0 hex 1 hex 0hex 43hex 0 Level resolution 1 Byte 0 hex 4 hex 0hex 44hex 0 45hex 0 46hex 0 47hex 0 48hex 0 49hex 0 4Ahex 0 4Bhex 0 4Chex 0 4Dhex 0 4Ehex 0 4Fhex 0 50hex 51hex Level mode segment 1 color Level mode segment 2 color Level mode segment 3 color Level mode segment 4 color* Level mode segment 5 color* Level mode limit 12 Level mode limit 23 Level mode limit 34* Level mode limit 45* Runlight mode background color Runlight mode running color Runlight mode number of running segments* hex 5hex* 1 Byte 0 hex F hex 2hex 1 Byte 0 hex F hex 3hex 1 Byte 0 hex F hex 1hex 3hex* 1 Byte 0 hex F hex 1hex 1 Byte 0 hex F hex 1hex 2 Byte 0 hex FFFF hex 2 Byte 0 hex FFFF hex AAhex CChex* 55hex 99hex* 2 Byte 0 hex FFFF hex 66hex 2 Byte 0 hex FFFF hex 33hex 1 Byte 0 hex 7 hex 0hex 1 Byte 0 hex 7 hex 1hex 1 Byte 1 hex 3 hex 1hex Supply monitoring 1 Byte 0 hex 3 hex Brightness 3 Byte 0 hex 7F7F7F hex 7F7F7F hex 52hex 0 Blinking frequency 1 Byte 1 hex 5 hex 2hex 53hex 0 Blinking mode 1 Byte *only in case of BNI IOL802000Z036 0 hex 07 hex 0 hex 1F hex* 0hex

19 Balluff / IOLink BNI IOL80x000Z03x 4 IOLink Interface Mode 40hex Number of segments 41hex Level type 42hex Level resolution 43hex Level mode segment x color 44hex, 45hex, 46hex, 47hex, 48hex Bit definition Segment x The operating mode of the module. 0 = Segment mode 1 = Level mode 2 = Runlight mode Number of the segments. Module Minimum value Maximum value BNI IOL801000Z BNI IOL802000Z Note, tip! When BNI IOL802000Z036 is configured to have 3 segments, 11 LED is always switched of between the segments. The type of the level indicator. 0 = bottom up 1 = top down The resolution of the input data in level mode. 0 = 8 bit 1 = 10 bit 2 = 12 bit 3 = 14 bit 4 = 16 bit Byte 0 Bit Bit 02, color of the x segment 000 = off 001 = green 010 = red 011 = yellow 100 = blue 101 = reserved 110 = reserved 111 = white Dominance 18 Segment x color Segment x color Segment x color Bit 3, color dominance 0 color is not dominant 1 color is dominant

20 4 IOLink Interface Level mode limit xy, 49hex, 4Ahex, 4Bhex, 4Chex An 8, 10, 12, 14, 16 bit number (depends on the resolution) determines the limits between two segments in level mode. The limit values are always right justified. Byte 0 1 Bit bit limit value 10 bit limit value 12 bit limit value 14 bit limit value 16 bit limit value

21 Balluff / IOLink BNI IOL80x000Z03x 4 IOLink Interface Runlight mode, background color 4Dhex Runlight mode, running color 4Ehex Runlight mode, number of running segments 4Fhex Byte 0 Bit Background color 20 Background color The color of the background in runlight mode Bit 02, background color 000 = off 001 = green 010 = red 011 = yellow 100 = blue 101 = reserved 110 = reserved 111 = white Byte 0 Background color Bit Running color Running color Running color The color of the running segment in runlight mode Bit 02, running color 000 = off 001 = green 010 = red 011 = yellow 100 = blue 101 = reserved 110 = reserved 111 = white Number of the running segments. Each segment contains 4 LED. Values between 1 and 3 can be set

22 4 IOLink Interface Supply monitoring 50hex Brightness 51hex Bit Sub Index 2 1 Under voltage Us 0: Us voltage is Ok 1: Low voltage on IOLink pin 1 LED Voltage failure 0: LED Voltage is Ok 1: LED Voltage failure 21 LED Voltage failure At three byte SPDU register sets the brightness for each channel (red, green, blue). Values from 0x00 to 0x7F are accepted. Byte 0 1 Under voltage Us Bit Sub Index Red brightness Red brightness Red brightness Byte Red brightness Red brightness Red brightness Bit Sub Index Blue brightness Blue brightness Blue brightness 3 Blue brightness Blue brightness Blue brightness Red brightness Blue brightness Green brightness Green brightness Green brightness Green brightness Green brightness Green brightness Green brightness

23 Balluff / IOLink BNI IOL80x000Z03x 4 IOLink Interface Blinking frequency 52hex Blinking mode 53hex The frequency of the blinking can be selected. It is only valid for 50% duty cycle blinking. The frequency of the flashing cannot be changed. Values between 1 and 5 are accepted. One means the slowest and five means the fastest blinking. Note, tip! The blinking frequency register affects not only blinking frequency, but the speed of the running light. Byte 1 Bit Segment 5 flashing* Segment 4 flashing* Segment 3 flashing 22 Segment 2 flashing * only in case of BNI IOL802000Z036 Segment x flashing bit sets the mode of the blinking. 0 blinking with 50% duty cycle 1 flashing Segment 1 flashing Note! Through this register only the mode of the blinking can be set (either 50% duty cycle or flash). The blinking of the desired segment must be activated in process data to enable blinking. 4.4 Errors Error Code 0x8011 Index not available 0x8012 Subindex not available 0x8023 Access Denied 0x8030 Parameter Value out of Range 0x8033 Paremeter length overrun 0x8034 Parameter length underrun 4.5 Events IOLink Revision 1.0 Event Code 0x5112 IOLink Revision 1.1 Event Code 0x5111 Low sensor voltage (US) Low sensor voltage (US)

24 5 Technical Data 5.1 Dimensions BNI IOL802000Z036 BNI IOL801000Z Mechanical data Housing Material Polycarbonate transparent diecast zinc housing IOLinkPort Enclosure rating Weight Dimensions (L W H, excluding connector) M12, Acoded, male IP67 (only when pluggedin and threadedin) BNI IOL801000Z036 ca. 400 g BNI IOL802000Z036 ca. 500 g BNI IOL801000Z036: mm BNI IOL802000Z036: mm 5.3 Electrical data Operating voltage ,2 V DC, per EN Ripple < 1 % 5.4 Operating conditions Current draw all segments off Current draw all segments white 40 ma BNI IOL801000Z036: 250 ma BNI IOL802000Z036: 400 ma Operating temperature 5 C +50 C Storage temperature 15 C +50 C EMC Immunity tests Emission tests EMCdirective 2004/108/EC EN :2005 EN :2007 Vibration/shock EN

25 Balluff / IOLink BNI IOL80x000Z03x 5 Technical Data 5.5 LED indicator Status LED Status LED LED Indicator Function Status LED Green, green flashing Status for supply and communication The status LED indicates the current status of the power supply and the communication. It can be switched on, switched of and flashing. Supply modul undervoltage Supply module ok Communication error LED is static off LED is static on Communication ok LED is flashing LED is flashing 24

26 6 Appendix 6.1 Product ordering code 6.2 Order information Type Order Code BNI IOL801000Z036 BNI007F BNI IOL802000Z036 BNI0072 Included material Balluff Networking Interface IOLink Interface 801: Smart Light 3 Segment 802: Smart Light 5 Segment Standard version Mechanical design Z036 = Diecast zinc housing, matte nickel plated Polycarbonate transparent housing Bus connection M12 external thread, Module fastening M18 external thread BNI IOL80x000Z036 consists of the following components: signal light M18x1 nut rubber foot screw M4 spring washer user s guide BNI IOL80x000Z

27 Balluff / IOLink BNI IOL80x000Z03x Notes 26

28 Balluff GmbH Schurwaldstrasse Neuhausen a.d.f. Germany Tel Fax balluff@balluff.de Nr E Edition 1306 Revised Edition 1304 Subject to modification

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide BNI IOL802102Z036 BNI IOL802102Z037 Smart Light User s Guide Content 1 Notes to the user 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical conventions 3 Enumerations 3 Actions 3 Syntax

More information

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide BNI IOL800000Z036 BNI IOL800000Z037 Smart Light User s Guide Content 1 Notes to the user 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical conventions 3 Enumerations 3 Actions 3 Syntax

More information

BNI IOL Z036 BNI IOL Z BNI IOL Z037 BNI IOL Z Smart Light User s Guide

BNI IOL Z036 BNI IOL Z BNI IOL Z037 BNI IOL Z Smart Light User s Guide BNI IOL802000Z036 BNI IOL802000Z036006 BNI IOL802000Z037 BNI IOL802000Z037006 Smart Light User s Guide Content 1 Notes to the user 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical

More information

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide BNI IOL801102Z036 BNI IOL801102Z037 Smart Light User s Guide Content 1 Notes to the user 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical conventions 3 Enumerations 3 Actions 3 Syntax

More information

BNI IOL Z012. User s Guide

BNI IOL Z012. User s Guide BNI IOL205000Z012 User s Guide Balluff Network Interface / BNI IOL205000Z012 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations

More information

BNI IOL K006 BNI IOL-106-S01-K006 BNI IOL-106-S01-K006-C01. User s Guide

BNI IOL K006 BNI IOL-106-S01-K006 BNI IOL-106-S01-K006-C01. User s Guide BNI IOL106000K006 BNI IOL106S01K006 BNI IOL106S01K006C01 User s Guide Content 1 Notes to the user 2 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 Enumerations 2 Actions

More information

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ026 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3 Syntax

More information

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide BNI IOL302000Z013 BNI IOL302S01Z013 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ013 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

BNI IOL-104-S01-Z012-C02

BNI IOL-104-S01-Z012-C02 BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302S01Z013C01 User s Guide Balluff Network Interface / IOLink 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical

More information

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide BNI IOL800000Z036 BNI IOL800000Z037 Smart Light User s Guide Content 1 Notes to the user 3 1.1 Structure of the guide 3 1.2 Typographical conventions 3 Enumerations 3 Actions 3 Syntax 3 Crossreferences

More information

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3

More information

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide BNI IOL302000K006 BNI IOL302000K006C01 BNI IOL302S01K006 BNI IOL302S01K006C01 IOLink 1.1 SensorHub / ActuatorHub User s Guide Content 1 Notes to the user 2 1.1 About this guide 2 1.2 Structure of the guide

More information

BNI IOL K006. IO Link Sensorhub digital User s Guide

BNI IOL K006. IO Link Sensorhub digital User s Guide BNI IOL-104-000-K006 BNI IOL-102-000-K006 IO Link Sensorhub digital User s Guide Content 1 Notes to the User 2 1.1. About this guide 2 1.2. Structure 2 1.3. Typographical conventions 2 Enumerations 2 Actions

More information

BNI IOL Z012 BNI IOL-302-S01-Z012 BNI IOL Z042

BNI IOL Z012 BNI IOL-302-S01-Z012 BNI IOL Z042 BNI IOL102000Z012 BNI IOL104000Z012 BNI IOL104S01Z012 BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302000Z012 BNI IOL302S01Z012 BNI IOL302000Z042 User s Guide Inhalt 1 Notes for the user 2 1.1. About

More information

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide BNI IOL102002Z019 IOLink 1.1 sensor hub With extension port User s Guide Balluff Network Interface / IOLink BNI IOL102002Z019 Inhalt 1 Notes for the user 4 1.1. About this manual 4 1.2. Structure of the

More information

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide BNI IOL104002Z046 IOLink 1.1 Sensor hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL104002Z046 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions

More information

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide BNI IOL302000K006 BNI IOL302000K006C01 BNI IOL302S01K006 BNI IOL302S01K006C01 IOLink 1.1 SensorHub / ActuatorHub User s Guide Content 1 Notes to the user 3 1.1 About this guide 3 1.2 Structure of the guide

More information

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide BNI IOL302002Z046 IOLink 1.1 sensor/actuator hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL302002Z046 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical

More information

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide Content 1 Notes 2 1.1. Struture of the guide 2 1.2. Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross references 2 1.3. Symbols

More information

BNI IOL A027 BNI IOL A027

BNI IOL A027 BNI IOL A027 BNI IOL-771-000-A027 BNI IOL-772-000-A027 IO-Link Version 1.1 Universel IO-Link Interface With undervoltage / broken coil detection User s Guide Inhalt 1 Notes to the user 2 1.1. About this guide 2 1.2.

More information

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide Content 1 s 2 1.1. About this guide 2 1.2. Struture of the guide 2 1.3. Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross references

More information

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide BNI IOL322E12 IOLink 1.1 sensor/actuator hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL322E12 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions

More information

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide BNI PBS-104-000-Z001 BNI PBS-302-000-Z001 BNI PBS-501-000-Z001 BNI PBS-502-000-Z001 Short Guide English 1 2 3 4 Notes to the User 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical

More information

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide BNI PBS-104-000-Z001 BNI PBS-102-000-Z001 BNI PBS-302-000-Z001 Quick start guide Content 1 Notes for the User 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typografical conventions 2 1.3.1 Enumerations

More information

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide BNI PNT-104-105-Z015 BNI PNT-202-105-Z015 BNI PNT-302-105-Z015 BNI PNT-305-105-Z015 IP67 Modules User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical

More information

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide BNI EIP-202-000-Z016 BNI EIP-202-100-Z016 IP67 Modules, 8 Outputs BNI EIP-206-000-Z016 BNI EIP-206-100-Z016 IP67 Modules, 16 Outputs User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure

More information

BNI PNT Z015. IP67 Modules 16 Input User s Guide

BNI PNT Z015. IP67 Modules 16 Input User s Guide BNI PNT-104-105-Z015 IP67 Modules 16 Input User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical Conventions 3 Enumerations 3 Actions 3 Syntax 3 Cross-references

More information

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide BNI PBS-502-001-Z001 IP67 module, Profibus IO-Link Master Short Guide 1 Notes for the User 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typografical conventions 2 1.3.1 Enumerations 2 1.3.2

More information

BNI USB A501. USB IO-Link Master User's Guide. english

BNI USB A501. USB IO-Link Master User's Guide. english User's Guide english 1 2 4 Notes to the user 1.1 About this guide 1.2 Structure of the guide 1. Typographical conventions 1.4 Symbols 1.5 Abbreviations Safety 4 2.1 Intended use 4 2.2 General safety notes

More information

BNI IOL Z012. User s Guide

BNI IOL Z012. User s Guide BNI IOL-719-002-Z012 User s Guide Content 1 Notes for the user 3 1.1. Structure of the guide 3 1.2. Typographical Conventions 3 Enumerations 3 Actions 3 Syntax 3 Cross references 3 1.3. Symbols 3 1.4.

More information

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide BNI PNT-502-105-Z015 IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical Conventions 3 Enumerations

More information

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide BNI DNT-104-000-Z004 BNI DNT-202-000-Z005 BNI DNT-302-000-Z005 BNI DNT-305-000-Z005 Short Guide English 1 2 3 4 Notes to the User 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical

More information

BNI IOL-75x-Vxx-K007 Valve Plug Short Guide

BNI IOL-75x-Vxx-K007 Valve Plug Short Guide BNI IOL-75x-Vxx-K007 Valve Plug Short Guide Content 1 Notes to the User 2 1.1. About this guide 2 1.2. Structure 2 1.3. Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross references 2

More information

BNI USB A501. User s Guide

BNI USB A501. User s Guide BNI USB-901-013-A501 User s Guide Content 1 Notes for the user 2 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross-references 2

More information

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide BNI PNT-104-105-Z015 BNI PNT-202-105-Z015 BNI PNT-206-105-Z015 BNI PNT-302-105-Z015 BNI PNT-305-105-Z015 IP67 Modules User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide

More information

BNI EIP Z016 IP67 Modules, 16 In-/Outputs User s Guide

BNI EIP Z016 IP67 Modules, 16 In-/Outputs User s Guide BNI EIP-302-100-Z016 IP67 Modules, 16 In-/Outputs User s Guide Balluff Network Interface EtherNet/IP, BNI EIP-302-100-Z016 1 Notes 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical

More information

BIS L x-07-S4

BIS L x-07-S4 BIS L-409-045-00x-07-S4 Quick Guide 41 English www.balluff.com 1 2 3 4 5 Notes to the user 5 1.1 bout this manual 5 1.2 Structure of the manual 5 1.3 Typographical conventions 5 1.4 Symbols 5 1.5 bbreviations

More information

BNI DNT Z001 DeviceNet IO-Link Master User s Guide

BNI DNT Z001 DeviceNet IO-Link Master User s Guide BNI DNT-52-1-Z1 DeviceNet IO-Link Master User s Guide Contents 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical conventions 3 Enumerations 3 Actions 3 Syntax 3 Cross-references

More information

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A User s Guide Table of contents 1 Safety 2 1.1. Installation and startup 2 1.2. General safety instructions 2 Hazardous

More information

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

BNI DNT Z001. DeviceNet IO-Link Master User s Guide BNI DNT-52-1-Z1 DeviceNet IO-Link Master User s Guide Contents 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical conventions 3 Enumerations 3 Actions 3 Syntax 3 Cross-references

More information

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide BNI PNT-502-105-Z015 BNI PNT-508-105-Z015 IP67 Module User s Guide Table of contents 1 General 3 1.1. About this manual 3 1.2. Structure of the manual 3 1.3. Typographical conventions 3 Enumerations 3

More information

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

BNI DNT Z001. DeviceNet IO-Link Master User s Guide BNI DNT-52-1-Z1 DeviceNet IO-Link Master User s Guide Contents 1 General 3 1.1. Structure of the Manual 3 1.2. Typographical conventions 3 Enumerations 3 Actions 3 Syntax 3 Cross-references 3 1.3. Symbols

More information

BNI EIP E002. EtherNet/IP IP69 modules User's Guide

BNI EIP E002. EtherNet/IP IP69 modules User's Guide BNI EIP-508-005-E002 EtherNet/IP IP69 modules User's Guide Table of Contents 1 General 3 1.1. Structure of the guide 3 1.2. Typographical Conventions 3 Enumerations 3 Actions 3 Syntax 3 Cross-references

More information

BNI EIP Z015 IP67 Modules 16 Inputs User s Guide

BNI EIP Z015 IP67 Modules 16 Inputs User s Guide BNI EIP-104-105-Z015 IP67 Modules 16 Inputs User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. tructure of the guide 3 1.3. Typographical Conventions 3 Enumerations 3 Actions 3 yntax 3 Cross-references

More information

BNI EIP Z015-C06. IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide

BNI EIP Z015-C06. IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide BNI EIP-508-105-Z015-C06 IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. tructure of the guide 3 1.3. Typographical Conventions 3 Enumerations

More information

Balluff Network Interface / CC-Link BNI-CCL Z001 BNI CCL Z001. Extended User Manual. 1

Balluff Network Interface / CC-Link BNI-CCL Z001 BNI CCL Z001. Extended User Manual.  1 BNI CCL-502-100-Z001 Extended User Manual www.balluff.com 1 1 Notes the User 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical Conventions 3 1.4 Symbols 3 1.5 Abbreviations 3 2 Safety

More information

BNI CCL Z001. CC-Link IO-Link Master User s Guide

BNI CCL Z001. CC-Link IO-Link Master User s Guide BNI CCL-502-100-Z001 CC-Link IO-Link Master User s Guide Table of Contents 1 Notes for the user 3 1.1. Conformity and user safety 3 1.2. About this guide 3 1.3. Structure of the guide 3 1.4. Typographical

More information

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005. User s Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005. User s Guide BNI DNT-104-000-Z004 BNI DNT-202-000-Z005 BNI DNT-302-000-Z005 BNI DNT-305-000-Z005 BNI DNT-305-007-Z005 User s Guide Contents 1 User instructions 3 1.1. Structure of the guide 3 1.2. Typographical conventions

More information

BNI EIP Z040. IP67 Module 4 IO-Link Class A and 8 in- and outputs 4 IO-Link Class B and 4 inputs User's Guide

BNI EIP Z040. IP67 Module 4 IO-Link Class A and 8 in- and outputs 4 IO-Link Class B and 4 inputs User's Guide BNI EIP-507-005-Z040 BNI EIP-527-005-Z040 IP67 Module 4 IO-Link Class A and 8 in- and outputs 4 IO-Link Class B and 4 inputs User's Guide Table of Contents 1 General 3 1.1. Structure of the manual 3 1.2.

More information

BNI EIP Z015. IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide

BNI EIP Z015. IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide BNI EIP-508-105-Z015 IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. tructure of the guide 3 1.3. Typographical Conventions 3 Enumerations

More information

BNI PNT Z015 BNI006C. IP67 Module User s Guide

BNI PNT Z015 BNI006C. IP67 Module User s Guide BNI PNT-502-102-Z015 BNI006C IP67 Module User s Guide Table of contents 1 General 4 1.1. About this manual 4 1.2. Structure of the manual 4 1.3. Typographical conventions 4 Enumerations 4 Actions 4 Syntax

More information

BIS L x-07-S4

BIS L x-07-S4 BIS L-409-045-00x-07-S4 Technical Description, User's Guide 41 English www.balluff.com 1 2 3 4 5 6 7 8 Notes to the user 5 1.1 bout this manual 5 1.2 Structure of the manual 5 1.3 Typographical conventions

More information

BNI PNT Z031 BNI PNT Z IP67 Module User s Guide

BNI PNT Z031 BNI PNT Z IP67 Module User s Guide BNI PNT-508-105-Z031 BNI PNT-508-105-Z031-002 BNI PNT-508-105-Z031-004 IP67 Module User s Guide Table of contents 1 General 4 1.1. About this manual 4 1.2. Structure of the manual 4 1.3. Typographical

More information

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Profibus IO Modules User's Guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Profibus IO Modules User's Guide BNI PBS-104-101-Z001 BNI PBS-202-101-Z001 BNI PBS-206-101-Z001 BNI PBS-302-101-Z001 Profibus IO Modules User's Guide Contents 1 Notes for the user 3 1.1 About this manual 3 1.2 Structure of the manual

More information

Profibus I/O Modules BNI PBS Z001 BNI PBS Z001

Profibus I/O Modules BNI PBS Z001 BNI PBS Z001 Profibus I/O Modules BNI PBS-104-000-Z001 BNI PBS-302-000-Z001 User's Guide 36.9 68.0 english www.balluff.com Balluff Network Interface / I/O Profibus Modules 1 2 3 4 5 6 7 8 Notes to the user 4 1.1 About

More information

BNI CIE Z015 BNI CIE Z015 BNI CIE Z015 BNI CIE Z015. CC-Link IE Field Standard I/O Modules User's Guide

BNI CIE Z015 BNI CIE Z015 BNI CIE Z015 BNI CIE Z015. CC-Link IE Field Standard I/O Modules User's Guide BNI CIE-104-105-Z015 BNI CIE-106-105-Z015 BNI CIE-302-105-Z015 BNI CIE-311-105-Z015 CC-Link IE Field Standard I/O Modules User's Guide Contents 1 Notes to the user 3 1.1. About this guide 3 1.2. Structure

More information

BNI EIP Z015 BNI EIP Z015. EtherNet/IP IP67 modules User's Guide

BNI EIP Z015 BNI EIP Z015. EtherNet/IP IP67 modules User's Guide BNI EIP-502-105-Z015 BNI EIP-508-105-Z015 EtherNet/IP IP67 modules User's Guide Table of Contents 1 Notes 3 1.1. Structure of the guide 3 1.2. Typographical Conventions 3 Enumerations 3 Actions 3 Syntax

More information

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide BNI PNT-502-105-Z015 BNI PNT-508-105-Z015 IP67 Module User s Guide Table of contents 1 General 4 1.1. Structure of the manual 4 1.2. Typographical conventions 4 Enumerations 4 Actions 4 Syntax 4 Cross-references

More information

BNI CCL Z001. CC-Link IO-Link Master User s Guide

BNI CCL Z001. CC-Link IO-Link Master User s Guide BNI CCL-502-100-Z001 CC-Link IO-Link Master User s Guide Table of Contents 1 Notes 3 1.1. Conformity and user safety 3 1.2. Structure of the guide 3 1.3. Typographical conventions 3 Enumerations 3 Actions

More information

BTL6-A_10-M -A1-S115. Data Sheet. english

BTL6-A_10-M -A1-S115. Data Sheet. english BT6-A_10-M -A1-S11 english Data Sheet Balluff GmbH Schurwaldstrasse 9 76 Neuhausen a.d.f. Germany Phone +49 (0) 71 8/1-0 Fax +49 (0) 71 8/0 10 Servicehotline +49 (0) 71 8/1-70 E-Mail: balluff@balluff.de

More information

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx EU Directive 2004/108/EC (EMC Directive) and EMC Law Generic Standards: EN 61000-6-4 (Emissions), EN 61000-6-2 (Interference Immunity) Emissions testing: Radio interference emissions EN 55011 Group 1,

More information

BNI EIP R015 BNI EIP R015. EtherNet/IP IP67 modules User's Guide

BNI EIP R015 BNI EIP R015. EtherNet/IP IP67 modules User's Guide BNI EIP-502-105-R015 BNI EIP-508-105-R015 EtherNet/IP IP67 modules User's Guide Table of Contents 1 Notes 3 1.1. About this guide 3 1.2. tructure of the guide 3 1.3. Typographical Conventions 3 Enumerations

More information

BIS M _ -07-S4 BIS M _ -07-S4

BIS M _ -07-S4 BIS M _ -07-S4 BIS M-4-045-00 _ -07-S4 BIS M-4-072-00 _ -07-S4 Technical Description, Operating Manual English www.balluff.com 1 2 3 4 5 6 7 8 User instructions 5 1.1 Conformity and user safety 5 1.2 Scope of delivery

More information

BNI CIE Z015 BNI CIE Z015. CC-Link IE Field IO-Link Master User's Guide

BNI CIE Z015 BNI CIE Z015. CC-Link IE Field IO-Link Master User's Guide BNI CIE-508-105-Z015 BNI CIE-518-105-Z015 CC-Link IE Field IO-Link Master User's Guide Contents 1 General 3 1.1. Structure of the guide 3 1.2. Typographical Conventions 3 Enumerations 3 Actions 3 Syntax

More information

BIS L , BIS Z-EL-...

BIS L , BIS Z-EL-... BIS L-400-..., BIS Z-EL-... Technical Description, User's Guide English www.balluff.com 1 2 3 4 5 6 7 8 9 Notes to the user 4 1.1 About this manual 4 1.2 Structure of the manual 4 1.3 Typographical conventions

More information

BTL6-V1 _ E-M -A1-S115 User's Guide

BTL6-V1 _ E-M -A1-S115 User's Guide User's Guide BTL1035 BTL6 V11E M0500 A1 S115 english www.balluff.com 1 Notes to the user 4 1.1 Validity 4 1.2 Symbols and conventions 4 1.3 Scope of delivery 4 1.4 Approvals and markings 4 1.5 Abbreviations

More information

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide BNI PNT-104-105-Z015 BNI PNT-202-105-Z015 BNI PNT-206-105-Z015 BNI PNT-302-105-Z015 BNI PNT-305-105-Z015 IP67 Modules User s Guide Content 1 Notes 3 1.1. Structure of the guide 3 1.2. Typographical Conventions

More information

GFK-2415A March Type of sensor connection

GFK-2415A March Type of sensor connection VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by

More information

BTL6-V11V-M -A1-S115 User's Guide

BTL6-V11V-M -A1-S115 User's Guide User's Guide english www.balluff.com 1 Notes to the user 4 1.1 Validity 4 1.2 Symbols and conventions 4 1.3 Scope of delivery 4 1.4 Approvals and markings 4 1.5 Abbreviations 4 2 Safety 5 2.1 Intended

More information

BIS M _ 0 _ -07-S4 BIS M _ 0 _ -07-S4

BIS M _ 0 _ -07-S4 BIS M _ 0 _ -07-S4 BIS M-4-045- _ 0 _ -07-S4 BIS M-4-072- _ 0 _ -07-S4 Technical Description, Operating Manual english www.balluff.com 1 User Instructions 5 1.1 Conformity and User Safety 5 1.2 Scope of Delivery 5 1.3 About

More information

AXL E IOL AO1 U M12 R

AXL E IOL AO1 U M12 R Axioline E IO-Link/analog converter for connecting an analog actuator, 0 V... 10 V, rectangular version Data sheet 8588_en_03 PHOENIX CONTACT 2014-09-22 1 Description The IO-Link/analog converter is an

More information

Manual Electronic Identification Systems BIS Processor BIS C-6_1 C6_1-023_9912-e.p65 Deutsch bitte wenden!

Manual Electronic Identification Systems BIS Processor BIS C-6_1 C6_1-023_9912-e.p65 Deutsch bitte wenden! 1 Manual lectronic Identification Systems BIS Processor BIS C-6_1 Deutsch bitte wenden! 2 No. 814 309 D/ dition 9912 Subject to modification. Replaces edition 9904. http://www.balluff.de Gebhard Balluff

More information

BIS M x-ST4 EtherNet/IP

BIS M x-ST4 EtherNet/IP Technical Description, Operating Manual English www.balluff.com 1 User Instructions 4 1.1 About this Manual 4 1.2 Typographical Conventions 4 1.3 Symbols 4 1.4 Meaning of Warning Notes 4 1.5 Abbreviations

More information

BIS M xx-ST4 PROFINET

BIS M xx-ST4 PROFINET Technical Description, Operating Manual english www.balluff.com 1 User Instructions 4 1.1 About this Manual 4 1.2 Typographical Conventions 4 1.3 Symbols 4 1.4 Abbreviations 5 2 Safety 6 2.1 Intended use

More information

BTL5-A/C/E1_-M- -SF-F User's Guide

BTL5-A/C/E1_-M- -SF-F User's Guide BTL5-A/C/E1_-M- -SF-F User's Guide english www.balluff.com 1 Notes to the user 1.1 Validity 1.2 Symbols and conventions 1.3 Scope of delivery 1. Approvals and markings 1.5 Abbreviations 2 Safety 5 2.1

More information

BIS V-6102 PROFIBUS. Technical Description, User s Guide. english 42,7 61,9 5,3 168,3 +6,0 157,6 +6,0 36,4 2,5 48,2

BIS V-6102 PROFIBUS. Technical Description, User s Guide. english 42,7 61,9 5,3 168,3 +6,0 157,6 +6,0 36,4 2,5 48,2 Technical Description, User s Guide 42,7 61,9 5,3 36,4 168,3 +6,0 157,6 +6,0 4 2,5 48,2 31 english www.balluff.com 1 User Instructions 4 1.1 About this Manual 4 1.2 Typographical Conventions 4 1.3 Symbols

More information

User's Manual. english

User's Manual. english BES M12EN-PFC40F-S04G-D11 BES M18EN-PFC80F-S04G-D11 BES M18MN-PFC50B-S04G-D11 BES M30EN-PFC15F-S04G-D11 BES M30MN-PFC10B-S04G-D11 Inductive Safety Sensors User's Manual english www.balluff.com Original

More information

BIS V-6102 Profibus. Technical Description, User's Guide. English 42,7 61,9 5,3 168,3 +6,0 157,6 +6,0 36,4 2,5 48,2

BIS V-6102 Profibus. Technical Description, User's Guide. English 42,7 61,9 5,3 168,3 +6,0 157,6 +6,0 36,4 2,5 48,2 Technical Description, User's Guide 42,7 61,9 5,3 36,4 168,3 +6,0 157,6 +6,0 4 2,5 48,2 31 English www.balluff.com 1 2 3 4 5 6 7 8 User instructions 4 1.1 About this manual 4 1.2 Typographical conventions

More information

BIS S-6027 Ethernet with TCP/IP-Protocol

BIS S-6027 Ethernet with TCP/IP-Protocol BIS S-6027 Ethernet with TCP/IP-Protocol Technical Description, User s Manual english www.balluff.com 1 2 3 4 5 6 7 8 9 User Notes 4 1.1 About this Manual 4 1.2 Manual layout 4 1.3 Conventions 4 1.4 Symbols

More information

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN Type 6150 AS-Interface Module Type 3372 Electropneumatic Actuator with AS-interface module Mounting and Operating Instructions EB 6150 EN Edition July 2013 Definition of the signal words used in these

More information

Manual LioN-P - IO-Link Device - I/O Hub

Manual LioN-P - IO-Link Device - I/O Hub Manual LioN-P - IO-Link Device - I/O Hub 0960 IOL 381-001 0960 IOL 385-001 0960 IOL 380-021 Technical Support support-automation@belden.com Contents Contents 1 About this Manual 6 1.1 General Information

More information

BNI EIP Z015 BNI EIP Z015 BNI EIP Z015. EtherNet/IP IP67 Modules User s Guide

BNI EIP Z015 BNI EIP Z015 BNI EIP Z015. EtherNet/IP IP67 Modules User s Guide BNI EIP-104-105-Z015 BNI EIP-202-105-Z015 BNI EIP-302-105-Z015 EtherNet/IP IP67 Modules User s Guide Content 1 Notes 3 1.1. tructure of the guide 3 1.2. Typographical Conventions 3 Enumerations 3 Actions

More information

Balluff smart safety BE ON THE SAFE SIDE. SAFETY OVER IO-LINK

Balluff smart safety BE ON THE SAFE SIDE. SAFETY OVER IO-LINK Balluff smart safety BE ON THE SAFE SIDE. SAFETY OVER IO-LINK 2 Balluff smart safety Simply safe SMART SAFETY. SAFETY WITH BALLUFF QUALITY. Balluff smart safety 3 Safety over IO-Link bridges the gap between

More information

BNI EIP Z015-C06. EtherNet/IP IP67 modules User's Guide

BNI EIP Z015-C06. EtherNet/IP IP67 modules User's Guide BNI EIP-508-105-Z015-C06 EtherNet/IP IP67 modules User's Guide Table of Contents 1 Notes 3 1.1. tructure of the guide 3 1.2. Typographical Conventions 3 Enumerations 3 Actions 3 yntax 3 Cross-references

More information

SCHMIDT Sensor interface PROFIBUS Instructions for use

SCHMIDT Sensor interface PROFIBUS Instructions for use SCHMIDT Sensor interface PROFIBUS Instructions for use Table of contents 1 Important information... 3 2 Intended use... 4 3 Electrical connection... 4 4 Signalizations... 7 5 Startup... 9 6 Technical data...

More information

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system

More information

2-Axis Counter BDD 622

2-Axis Counter BDD 622 2-Axis Counter BDD 622 Technical Description, User's Guide english No. 622-221 D/E. Edition 0701; Subject to modification. www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany

More information

VersaMax IP Input Module

VersaMax IP Input Module Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm

More information

CMC III Universal Sensor

CMC III Universal Sensor CMC III Universal Sensor DK 7030.190 Assembly and operating instructions Foreword Foreword Dear Customer, Thank you for choosing our CMC III universal sensor (referred to hereafter as "universal sensor")!

More information

BIS L-6026 EtherNet/IP

BIS L-6026 EtherNet/IP Technical Description, User s Manual english www.balluff.com 1 2 3 4 5 6 7 8 9 User Notes 4 1.1 About this Manual 4 1.2 Manual layout 4 1.3 Conventions Enumerations 4 1.4 Symbols 4 1.5 Abbreviations 5

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI711S / / 2010 Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding

More information

VersaMax IP I/O Module

VersaMax IP I/O Module Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)

More information

READ/WRITE MODULES (RWM) RLS

READ/WRITE MODULES (RWM) RLS HOUSING M READ/WRITE DISTANCE mm* HF RFID SYSTEM READ/WRITE MODULES (RWM) RLS-- ü M Metal threaded housing ü Sensing face of PBTP ü Insensible to dirt ü IO-Link V. Mx ü x PNP output in SIO mode configurable

More information

Powertrain Assembly Transparency and efficiency in manufacturing and installation

Powertrain Assembly Transparency and efficiency in manufacturing and installation Your complete provider for Systems and Service From the design and planning of your projects To testing and setup on-site To training and support Vision sensors BVS For automated quality assurance The

More information

Manual Electronic Identification Systems BIS Processor BIS L-60_0 RS232 L-60_0-RS232_829572_0311_e.p65 Deutsch bitte wenden!

Manual Electronic Identification Systems BIS Processor BIS L-60_0 RS232 L-60_0-RS232_829572_0311_e.p65 Deutsch bitte wenden! 1 Manual lectronic Identification Systems BIS Processor BIS L-60_0 RS232 Deutsch bitte wenden! 2 No. 829 572 D/ dition 0311 Subject to modification. http://www.balluff.de Balluff GmbH Schurwaldstrasse

More information

BIS V-6111 CC-Link. Technical Description, User's Guide. English

BIS V-6111 CC-Link. Technical Description, User's Guide. English Technical Description, User's Guide English www.balluff.com 1 Contents 2 3 4 5 6 8 User Instructions 4 1.1 About This Manual 4 1.2 Typographical Conventions 4 1.3 Symbols 4 1.4 Abbreviations 4 Safety 5

More information

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10 4070.83/4--10 PumpDrive DPM Installation and Operating Instructions Dual Pump Module (DPM) These installation and operating instructions are not valid on their own. They must always be applied in conjunction

More information

BIS V-6106 Ethernet/IP Technical Reference, Operating Manual

BIS V-6106 Ethernet/IP Technical Reference, Operating Manual BIS V-6106 Ethernet/IP Technical Reference, Operating Manual english www.balluff.com 1 User Instructions 4 1.1 About This Manual 4 1.2 Typographical Conventions 4 1.3 Symbols 4 1.4 Meaning of Warnings

More information