READ/WRITE MODULES (RWM) RLS

Size: px
Start display at page:

Download "READ/WRITE MODULES (RWM) RLS"

Transcription

1 HOUSING M READ/WRITE DISTANCE mm* HF RFID SYSTEM READ/WRITE MODULES (RWM) RLS-- ü M Metal threaded housing ü Sensing face of PBTP ü Insensible to dirt ü IO-Link V. Mx ü x PNP output in SIO mode configurable ü RWM reconfigurable via a Master Tag SW Ø LED (x) Mx * Please refer to table page GENERAL DATA INTERFACE Carrier frequency. MHz Data transfer rate baud Compatible standard ISO 9 LED green on RWM live Maximum transmission speed. kbit/s LED green blinking IO-Link communication Read-write distance max. mm with RTP-- LED yellow on Transponder detected LED yellow blinking Transponder + IO-Link communication IO-Link ü ELECTRICAL DATA MECHANICAL DATA Supply voltage range (Ub)... VDC Protection degree IP No-load supply current (field off) ma Ambient temperature range TA* C Max. current consumption (no load) ma Storage temperature range TS** C Polling current ma Sensing face material PBTP Short-circuit protection ü Housing material Chrome-plated brass Voltage reversal protection ü Connector type M -pin Max. output current ma Weight (incl. nuts) g * Read/write operations possible ** Data retention and mechanical stability limit route du Pâqui - P.O. Box - CH Corminboeuf - Switzerland - Tel: + - Fax: + - Internet: info@contrinex.com

2 MOUNTING RECOMMENDATIONS CLEARANCE Read/write modules must not mutually influence each other. For this reason a minimum distance of x D between the devices must be observed. D D D sensing face mm metal free zone support WIRING DIAGRAM PIN ASSIGNMENT bk wh bu L+ C/Q Q L- Pin Signal Function L+ + V Q DO (tag presence or data comparison) L- OV C/Q SDCI/SIO (tag presence or data comparison) M IO-Link characteristics Value for RLS-- IO-Link Protocol. COM-Mode COM (. kbaud) Min. cycle time. ms Process data width in bytes Process data width out 9 bytes Profile Smart Sensor Profile SIO-Mode support Yes Port type A Memory request for data management bytes Device ID xab Vendor ID x route du Pâqui - P.O. Box - CH Corminboeuf - Switzerland - Tel: + - Fax: + - Internet: info@contrinex.com

3 CONFIGURATION PARAMETER (IO-LINK / SIO MODE) Index Sub Hex Name Access Data Type Value Default IDENTIFICATION Vendor Name R char [] Contrinex h Vendor Text R char [] h Product Name R char [] RLS-- Product ID R char [] h Product Text R char [] IO-Link RFID reader h Serial Number R char [] h Firmware Revision R char [].9. h Application Specific Tag R/W char [] <user string byte (variable length)> READER PARAMETER PROCESS DATA <vendor specific> Operating Mode R/W h Data Hold Time R/W : Scan UID : Scan User Data : Read / Write Command : No Hold Time : Hold Time ms : Hold Time ms h : Hold Time ms : Hold Time ms h : Hold Time ms Scan Address R/W Address to scan READER PARAMETER SIO h C/Q PIN SIO Operating Mode R/W : Presence Transponder : Compare Data : No SIO h C/Q SIO Data to compare H R/W uint Comparison value Byte to C/Q SIO Data to compare L R/W uint Comparison value Byte to h SIO Compare Data Address (C/Q & Q) R/W Comparison address for C/Q and Q (A valid address must be chosen) h Data Hold Time Output (C/Q & Q) R/W : No Hold Time : Hold Time ms : Hold Time ms h : Hold Time ms : Hold Time ms h : Hold Time ms h C/Q PIN SIO Polarity R/W h Q PIN SIO Operating Mode R/W : Output close if condition = true : Output open if condition = true : Presence Transponder : Compare data (C/Q must be also in compare data) : No SIO h Q SIO Data to compare H R/W uint Comparison value Byte to 9 h Q SIO Data to compare L R/W uint Comparison value Byte to A h Q PIN SIO Polarity R/W : Output close if condition = true : Output open if condition = true route du Pâqui - P.O. Box - CH Corminboeuf - Switzerland - Tel: + - Fax: + - Internet: info@contrinex.com

4 PROCESS DATA REPRESENTATION PROCESS DATA MODE SCAN UID MODE PROCESS DATA INPUT TAG ANT NB TAG UID UID UID UID UID UID UID UID TAG : ANT : NB TAG : UID : UID : = No tag present in front of the RWM = tag or more present in front of the RWM = RF field off = RF field on Number of tag in front of the RWM UID LSB UID MSB PROCESS DATA OUTPUT N_ANT TAG NB N_ANT : TAG NB : = Switch on RF field = Switch off RF field Index of tag to be printed in UID area (index from ) PROCESS DATA MODE SCAN USER DATA PROCESS DATA INPUT RDY ERR TAG ANT EXT Data / Error Code Data Data Data Extended Data Extended Data Extended Data Extended Data PROCESS DATA OUTPUT RDY : ERR : TAG : ANT : EXT : Data : Data / : = No data available yet = Memory scanned and data available = Memory scanned and no error = Memory scanned but error; = No tag present in front of the RWM = Tag present in front of the RWM = RF field off = RF field on = bytes data = bytes data User data LSB / Error Code User data MSB N_ANT N_ANT : = Switch on RF field = Switch off RF field route du Pâqui - P.O. Box - CH Corminboeuf - Switzerland - Tel: + - Fax: + - Internet: info@contrinex.com

5 PROCESS DATA MODE READ/WRITE PROCESS DATA INPUT RDY ERR TAG ANT EXT Data / Error Code Data Data Data Extended Data Extended Data Extended Data Extended Data RDY : ERR : TAG : ANT : EXT : Data : Data / : = No data available yet = Command executed and data ready for user = Command executed and no error = Command executed but error = No tag present in front of the RWM = Tag present in front of the RWM = RF field off = RF field on = bytes data = bytes data Read data LSB / Error Code Read data MSB Error Code Definition CommandNotSupported = FormatError = OptionNotSupported = CommandProblem = CommTagError = TagError = NoMomoryBloc = BlocProtected = PROCESS DATA OUTPUT 9 START N_ANT CMD EXT ADD Data Data Data Data Extended Data Extended Data Extended Data Extended Data START : N_ANT : CMD : EXT : ADD : Data : Data / : = Do not execute the command = Execute the command = Switch on RF field = Switch off RF field = No command = Read = Write = bytes data = bytes data Block address Write data LSB Write data MSB SYSTEM COMMAND (idx h ) Value hex Value dec Function h ParamDownloadStore Device Reset h Restore factory settings* *always do a reset after the restore of factory settings route du Pâqui - P.O. Box - CH Corminboeuf - Switzerland - Tel: + - Fax: + - Internet: info@contrinex.com

6 MASTER TAG CONFIGURATION For the RLS-- the IO-Link mode or the SIO (standard I/O mode) can be configured via IO-Link or via a Master Tag. For the configuration via a Master Tag a transponder (called Master Tag) will contain all the data used for the configuration. The structure of the data are explained in the table on page. There is a simple procedure to configure the RWM. Once all the data are written in the Master Tag you need to put it in front of the RWM sensing face to switch off the RWM power supply and to switch on again. The RWM will detect that it s a Master Tag and read all the data and configure the outputs accordingly. On the Contrinex webpage ( it is possible to download a software to setup the Master Tag via a Contrinex USB RWM. This program is called IO-Link Master Tag programmer. SIO MODE POSSIBILITIES If you use the RLS-- in a SIO mode you will have two main possibilities:. Presence Transponder: In this mode the output will switch if a transponder is in the field of the RWM.. Compare Data: In this mode the output will switch if the data red in the defined block memory of the transponder matches with the data stocked in the RWM. MASTER TAG To build a Master Tag it s possible to use any ISO9 chip with at least eight memory blocks with bits each. route du Pâqui - P.O. Box - CH Corminboeuf - Switzerland - Tel: + - Fax: + - Internet: info@contrinex.com

7 CONFIGURATION PARAMETER (IO-LINK / SIO MODE) Bloc + A:H Byte Offset Name Data Type Value Default Comment READER PARAMETER PROCESS DATA (IO-LINK MODE) Operating Mode : Scan UID : Scan User Data : Read / Write Command See process data organisation h h Data Hold Time : No Hold Time : Hold Time ms : Hold Time ms h : Hold Time ms : Hold Time ms h : Hold Time ms h h Scan Address Address to scan Addres to scan in user data READER PARAMETER SIO (SIO MODE) C/Q PIN SIO Operating Mode : Presence Transponder : Compare Data : No SIO h... h C/Q SIO Data to compare H uint Comparison value Byte to Ext. Data Ext. Data Ext. Data Ext. Data h... h C/Q SIO Data to compare L uint Comparison value Byte to Data Data Data Data C h Address (C/Q & SIO Compare Data Q) Comparison address for C/Q and Q (A valid address must be chosen) h D h Output (C/Q & I/ Data Hold Time Q) : No Hold Time : Hold Time ms : Hold Time ms h : Hold Time ms : Hold Time ms h : Hold Time ms h E h C/Q PIN SIO Polarity : Output close if condition = true : Output open if condition = true h F h Q PIN SIO Operating Mode : Presence Transpondere : Compare Data : No SIO h... Q SIO Data to compare H uint Comparison value Byte to Ext. Data Ext. Data Ext. Data Ext. Data h... h Q SIO Data to compare L uint Comparison value Byte to Data Data Data Data h h Q PIN SIO Polarity : Output close if condition = true : Output open if condition = true CRC h... C h CRC CHECK uint CRC on all config field with polynom: X +X +X +X +X +X +X + X +X +X +X +X +X +X +X route du Pâqui - P.O. Box - CH Corminboeuf - Switzerland - Tel: + - Fax: + - Internet: info@contrinex.com

8 POSSIBLE COMBINATION AND TYPICAL DISTANCE - RLS-- Transponder type S max S D Ø 9 RTP-9-9. Ø RTP--. 9 Ø RTP-- 9 Ø RTP-- 9 Ø RTP-- Ø RTP-- Read/Write Module Working area Transponder D RLS- - y x S S max AVAILABLE TYPES Part number Part reference Ø Mounting Connection RLS-- M Non-embeddable M -pin Operators of the products we supply are responsible for compliance with measures for the protection of persons. The use of our equipment in applications where the safety of persons might be at risk is only authorized if the operator observes and implements separate appropriate and necessary measures for the protection of persons and machines. Terms of delivery and rights to change design reserved. route du Pâqui - P.O. Box - CH Corminboeuf - Switzerland - Tel: + - Fax: + - Internet: info@contrinex.com RLS-- YAG

READ/WRITE MODULES (RWM) RLS

READ/WRITE MODULES (RWM) RLS HF RFID SYSTEM READ/WRITE MODULES (RWM) RLS-- HOUSING M READ/WRITE DISTANCE. mm* ü M Metal threaded housing ü Sensing face of PBTP ü Insensible to dirt ü IO-Link V. ü x PNP output in SIO mode configurable

More information

Low frequency High frequency

Low frequency High frequency Low-frequency Technology Highlights: ü All-metal components for aggressive operating environments ü Embeddable transponders ü Transponders can be written to and read through metal ü Memory of transponders:

More information

High and Low-frequency Radio Frequency Identification Systems (RFID)

High and Low-frequency Radio Frequency Identification Systems (RFID) High and Low-frequency Radio Frequency Identification Systems (RFID) Highlights Reading & writing through metal Mechanically & chemically resistant all-metal components (V2A & V4A) High-temperature resistant

More information

Inductive proximity switches with long operating distance, series 500

Inductive proximity switches with long operating distance, series 500 Inductive proximity switches with long operating distance, series 500 Highlights World's longest operating distances on steel Sizes Ø 4... M30 embeddable (Ø 4 and M5), (... M30) and non-embeddable (M...

More information

HM Detailed data sheets for these products can be found on the Contrinex website:

HM Detailed data sheets for these products can be found on the Contrinex website: HM- Detailed data sheets for these products can be found on the Contrinex website: the contrinex network low frequency high frequency KEY ADVANTAGES ü Powerful RS network for LF and HF systems ü Threaded

More information

Radio Frequency Identification System (RFID)

Radio Frequency Identification System (RFID) Radio Frequency Identification System (RFID) Highlights: 125 khz technology Transponders with 2 kbit of read/write memory Impervious transponders in all-metal housings Compact read/write modules Read/write

More information

Operating instructions Memory plug E /02 11/2011

Operating instructions Memory plug E /02 11/2011 Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5

More information

BACKGROUND SUPPRESSION LHR-C12PA-NM

BACKGROUND SUPPRESSION LHR-C12PA-NM PHOTOELECTRIC SENSOR BACKGROUND SUPPRESSION LHR-C2PA-NM 30 mm ü Subminiature housing ü Small visible light spot OPTICAL DATA INTERFACE Sensing range max....36 mm Sensitivity adjustment No Operating range...30

More information

Dimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31

Dimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31 OBEM-R00-SEP-IO-V Dimensions. 8.7. 7..9. M (x).. ø... 0 9.9 7. 7. Release date: 08-06-08 :0 Date of issue: 08-06-08 80998_eng.xml Model Number OBEM-R00-SEP-IO-V Thru-beam sensor with -pin, M8 x connector

More information

UNAM 12I9912/S14. Ultrasonic distance measuring sensors. Ultrasonic sensors. Analog. dimension drawing. general data. photo

UNAM 12I9912/S14. Ultrasonic distance measuring sensors. Ultrasonic sensors. Analog. dimension drawing. general data. photo UNAM 12I9912/S14 dimension drawing SW 17 55 70 LED general data photo scanning range Sd scanning range close limit Sdc scanning range far limit Sde repeat accuracy < 0,5 mm resolution < 0,3 mm response

More information

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide BNI IOL322E12 IOLink 1.1 sensor/actuator hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL322E12 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions

More information

Capacitive proximity switches

Capacitive proximity switches Capacitive proximity switches Capacitive proximity switches Introduction Capacitive proximity switches are used in machines, installations and vehicles for monitoring the levels of liquids, pastes and

More information

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide BNI IOL104002Z046 IOLink 1.1 Sensor hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL104002Z046 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions

More information

Type 2 light curtains for hand protection

Type 2 light curtains for hand protection General Catalog new INDUCTIVE SENSORS Full Inox Basic with IO-Link Full Inox Weld-Immune, M8 Full Inox C3, cubic with IO-Link High Temperature, 30 C (440 F) photoelectric SENSORS Contrast sensor with IO-Link

More information

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing Dimensioned drawing en 2-214/2 5124879 25 4mm 15 13mm 15-3 V DC We reserve the right to make changes DS_HTU418BX3LT4_en_5124879.fm Largely surface-independent function, ideal for the detection of liquids,

More information

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide BNI IOL302002Z046 IOLink 1.1 sensor/actuator hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL302002Z046 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical

More information

BIS L x-07-S4

BIS L x-07-S4 BIS L-409-045-00x-07-S4 Quick Guide 41 English www.balluff.com 1 2 3 4 5 Notes to the user 5 1.1 bout this manual 5 1.2 Structure of the manual 5 1.3 Typographical conventions 5 1.4 Symbols 5 1.5 bbreviations

More information

mobile data carrier TW-R16-B128 Phone: Fax: Web: -

mobile data carrier TW-R16-B128 Phone: Fax: Web:  - Mobile data carrier TW-R6-B28 mobile data carrier read/write compatible with a series of BL ident read-write heads (see data sheet or compatibility table) EEPROM, memory size 28 bytes Type TW-R6-B28 Ident-No.

More information

4 Ultrasonic proximity switches

4 Ultrasonic proximity switches Highlights: - Ready-to-connect compact devices - Short housing lengths - Adjustment by means of teach-in, potentiometer and / or interface with PC software - Devices with digital and / or analog outputs

More information

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing ADVANCED ultrasonic sensors with 2 switching outputs Dimensioned drawing en 4-214/12 5124879 25 4mm 15 13mm 15-3 V DC We reserve the right to make changes DS_HTU418BX3LT4_en_5124879.fm Function largely

More information

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide BNI IOL102002Z019 IOLink 1.1 sensor hub With extension port User s Guide Balluff Network Interface / IOLink BNI IOL102002Z019 Inhalt 1 Notes for the user 4 1.1. About this manual 4 1.2. Structure of the

More information

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Online data sheet VL18-4P3140 V18 CYLINDRICAL PHOTOELECTRIC SENSORS

Online data sheet VL18-4P3140 V18 CYLINDRICAL PHOTOELECTRIC SENSORS Online data sheet VL8-P0 V8 VL8-P0 V8 A B C D E F Illustration may differ Ordering information Type Part no. VL8-P0 605 Other models and accessories www.sick.com/v8 H I J K L M N O P Q R S T Detailed technical

More information

Online data sheet VS/VE18-4P3140 V18 CYLINDRICAL PHOTOELECTRIC SENSORS

Online data sheet VS/VE18-4P3140 V18 CYLINDRICAL PHOTOELECTRIC SENSORS Online data sheet VS/VE8-P0 V8 VS/VE8-P0 V8 A B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Sensor/ detection principle Housing design (light emission) Housing

More information

Online data sheet VTE18-4P4240 V18 CYLINDRICAL PHOTOELECTRIC SENSORS

Online data sheet VTE18-4P4240 V18 CYLINDRICAL PHOTOELECTRIC SENSORS Online data sheet VTE8-P0 V8 VTE8-P0 V8 A B C D E F Illustration may differ Ordering information Type Part no. VTE8-P0 606 Other models and accessories www.sick.com/v8 H I J K L M N O P Q R S T Detailed

More information

RS485 MODBUS Module 8I8O

RS485 MODBUS Module 8I8O Expansion Module 8 digital inputs, 8 digital outputs Version 2.2 12/01/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the

More information

Identification System CIS3A-Mini

Identification System CIS3A-Mini Inductive Identification System CISA-Mini One of the smallest plug-in read heads Interface adapter for fitting on the DIN rail in the control cabinet Miniature data carrier, diameter 10 x 4 mm Read distance

More information

Technical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means

Technical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE Switch output and analog output Selectable sound lobe width Synchronization options

More information

hipecs-cio100 CANopen I/O module with 16/16 digital I/O

hipecs-cio100 CANopen I/O module with 16/16 digital I/O General The hipecs-cio100 is a low cost CANopen unit with 16 digital inputs and 16 digital outputs suitable for 24 V DC applications. The I/O s are positive switching and opto-isolated from the bus and

More information

BNI IOL K006. IO Link Sensorhub digital User s Guide

BNI IOL K006. IO Link Sensorhub digital User s Guide BNI IOL-104-000-K006 BNI IOL-102-000-K006 IO Link Sensorhub digital User s Guide Content 1 Notes to the User 2 1.1. About this guide 2 1.2. Structure 2 1.3. Typographical conventions 2 Enumerations 2 Actions

More information

OEM Proximity Reader with Keypad Manual REV1

OEM Proximity Reader with Keypad Manual REV1 484-52 OEM Proximity Reader with Keypad Manual REV1 Overview The 484-52 proximity keypad reader provides pin code identification to be used together with a proximity identification card. The 484-52 consists

More information

RS485 MODBUS Module 16I-M

RS485 MODBUS Module 16I-M Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide BNI IOL302000Z013 BNI IOL302S01Z013 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ013 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3 Syntax

More information

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ026 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

RS485 MODBUS Module 6RO

RS485 MODBUS Module 6RO Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

FRW 13.56MHz - ISO15693 READER/WRITER

FRW 13.56MHz - ISO15693 READER/WRITER Ek20 RFID TRANSPONDER TECHNOLOGY DOC. 147-R4 FRW 13.56MHz - ISO15693 READER/WRITER FRW-PCB FRW-ONDA FRW-SHELL FRW-BOX FRW-USBN FRW-POCKET USBN 1.0 FEATURES AND SPECIFICATIONS The FRW is a Front Side Serial

More information

BNI IOL Z036 BNI IOL Z036

BNI IOL Z036 BNI IOL Z036 BNI IOL801000Z036 BNI IOL802000Z036 Smart Light User s Guide Content 1 Notes to the user 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical conventions 3 Enumerations 3 Actions 3 Syntax

More information

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for Version 1.2 20.01.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

BNI IOL K006 BNI IOL-106-S01-K006 BNI IOL-106-S01-K006-C01. User s Guide

BNI IOL K006 BNI IOL-106-S01-K006 BNI IOL-106-S01-K006-C01. User s Guide BNI IOL106000K006 BNI IOL106S01K006 BNI IOL106S01K006C01 User s Guide Content 1 Notes to the user 2 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 Enumerations 2 Actions

More information

BIS M _ 0 _ -07-S4 BIS M _ 0 _ -07-S4

BIS M _ 0 _ -07-S4 BIS M _ 0 _ -07-S4 BIS M-4-045- _ 0 _ -07-S4 BIS M-4-072- _ 0 _ -07-S4 Technical Description, Operating Manual english www.balluff.com 1 User Instructions 5 1.1 Conformity and User Safety 5 1.2 Scope of Delivery 5 1.3 About

More information

BNI IOL Z012. User s Guide

BNI IOL Z012. User s Guide BNI IOL205000Z012 User s Guide Balluff Network Interface / BNI IOL205000Z012 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations

More information

Technical Data. Dimensions

Technical Data. Dimensions Model Number Features 50 mm flush -wire DC S Technical Data specifications Switching function Normally open (NO) Output type PNP Rated operating distance s n 50 mm Installation flush Output polarity DC

More information

MRUC-20 Modul-R CAN Bus Network

MRUC-20 Modul-R CAN Bus Network MRUC-20 Modul-R CAN Bus Network BALOGH This manual is based on information available at the time if its publication. Every effort has been made to provide accurate and up-to-date information. This document

More information

BNI IOL A027 BNI IOL A027

BNI IOL A027 BNI IOL A027 BNI IOL-771-000-A027 BNI IOL-772-000-A027 IO-Link Version 1.1 Universel IO-Link Interface With undervoltage / broken coil detection User s Guide Inhalt 1 Notes to the user 2 1.1. About this guide 2 1.2.

More information

BNI IOL-104-S01-Z012-C02

BNI IOL-104-S01-Z012-C02 BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302S01Z013C01 User s Guide Balluff Network Interface / IOLink 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical

More information

hipecs-cio52 CANopen I/O module with 4 analog outputs

hipecs-cio52 CANopen I/O module with 4 analog outputs General The hipecs-cio52 is a low-cost CANopen module with 4 analog output lines. The I/O are isolated from power supply and the CAN bus sub system. Furthermore, the module has an output resolution of

More information

RFID TRANSPONDER TECHNOLOGY

RFID TRANSPONDER TECHNOLOGY RFID TRANSPONDER TECHNOLOGY DOC. 113-R8 TRW SERIAL TYPE QT - Q5/T5567/T5557 TRW-PCB TRW-ONDA TRW-SHELL TRW-BOX TRW-USB TRW-POCKET USB 1.0 FEATURES AND SPECIFICATIONS The TRW is a Serial Tag Reader/Writer

More information

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide BNI IOL302000K006 BNI IOL302000K006C01 BNI IOL302S01K006 BNI IOL302S01K006C01 IOLink 1.1 SensorHub / ActuatorHub User s Guide Content 1 Notes to the user 3 1.1 About this guide 3 1.2 Structure of the guide

More information

USB-B1 v2 User Manual V1.3 23/01/2018

USB-B1 v2 User Manual V1.3 23/01/2018 USB-B1 v2 User Manual V1.3 23/01/2018 Table of Contents 1. Introduction...2 1.1 Device Overview... 2 1.2 System Overview... 3 1.3 Features... 3 1.4 Connectors... 4 1.4.1 USB Connector (J1)... 4 1.4.2 External

More information

AXL E IOL AO1 U M12 R

AXL E IOL AO1 U M12 R Axioline E IO-Link/analog converter for connecting an analog actuator, 0 V... 10 V, rectangular version Data sheet 8588_en_03 PHOENIX CONTACT 2014-09-22 1 Description The IO-Link/analog converter is an

More information

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1 TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT NOTICE... 2 PRODUCT CONFORMITY... 3 WARRANTY AND SAFETY INSTRUCTIONS... 4 1 GENERAL... 5 1.1 SATEL I-LINK 100 MODBUS I/O- CONVERTER... 5 2 SPECIFICATIONS...

More information

optical sensors through-beam, retro-reflective, dif. reflection sensors 3000 transmitter with test input robust metal housing

optical sensors through-beam, retro-reflective, dif. reflection sensors 3000 transmitter with test input robust metal housing design 12 x 12 x 64mm 12 x 12 x 69mm 12 x 12 x 74mm operating distance retro-reflective sensor operating distance diffuse reflection sensor sensing range up to 6.0m up to 4.0m up to 1.2m metal housing

More information

Dimensions. Model Number. Electrical connection. Features. Pinout. Indicators/operating means. Product information OQT150-R100-2EP-IO-V31

Dimensions. Model Number. Electrical connection. Features. Pinout. Indicators/operating means. Product information OQT150-R100-2EP-IO-V31 Dimensions.5 8.7 5.5.5. M (x)..5 7. 5.. 0 5.9 7. 9.95 Reveiver Emitter ø. Model Number Triangulation sensor (SbR) with -pin, M8 x connector Features Miniature design with versatile mounting options Multi

More information

RS485 MODBUS Module 8AO

RS485 MODBUS Module 8AO Version 1.3 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

4. Sensing Distance. 2: 2 mm. 4: 4 mm 8: 8 mm 15: 15 mm 16: 16 mm 20: 20 mm

4. Sensing Distance. 2: 2 mm. 4: 4 mm 8: 8 mm 15: 15 mm 16: 16 mm 20: 20 mm Inductive Sensor Double Sensing Distance Model Number Legend SALIENT FEATURES IP - 7, Brass Housing Short - Circuit protection Reverse Polarity Protection Shielded and Non - Shielded Prewired and Connector

More information

Encoders Absolute Singleturn Encoder Types A58CS8

Encoders Absolute Singleturn Encoder Types A58CS8 Types A58CS8 Sturdy design with hardened bearings High rotation speed -40...+80 C/-40...+76 F operating temperature range High shock and vibration resistance Magnetic field proof also available as explosion

More information

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to

More information

TW-R7.5-B PCS. EEPROM, memory 128 byte. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission

TW-R7.5-B PCS. EEPROM, memory 128 byte. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission EEPROM, memory 12 byte Functional principle The HF read/write heads operating at a frequency of.56 MHz, form a transmission zone the size of which (0 500 mm) varies, depending on the combination of read/write

More information

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide BNI IOL800000Z036 BNI IOL800000Z037 Smart Light User s Guide Content 1 Notes to the user 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical conventions 3 Enumerations 3 Actions 3 Syntax

More information

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A User s Guide Table of contents 1 Safety 2 1.1. Installation and startup 2 1.2. General safety instructions 2 Hazardous

More information

MU-Thermocouple1 CAN. Temperature Measurement Unit with CAN Connection. User Manual

MU-Thermocouple1 CAN. Temperature Measurement Unit with CAN Connection. User Manual MU-Thermocouple1 CAN Temperature Measurement Unit with CAN Connection User Manual Products taken into account Product Name Model Item Number MU-Thermocouple1 CAN Metal-cased measuring unit IPEH-002205

More information

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3

More information

Inductive displacement measurement system model series IE25P with programmable analogue interface

Inductive displacement measurement system model series IE25P with programmable analogue interface Inductive displacement measurement system Document No.: IE 12781 BE Date: 05.01.16 Contactless, wear-free sensor system Analogue interface Measuring range programmable Measuring range up to 0 mm Stainless

More information

standard, short, preferential, top

standard, short, preferential, top ipf electronic gmbh Kalver Straße 27 standard design short design preferential series top series standard, short, preferential, top norm sensing ranges, increased sensing ranges 1100 1 2 1100 norm sensing

More information

GEMÜ 1235 Electrical position indicator

GEMÜ 1235 Electrical position indicator Electrical position indicator Features Communication and programming interface IO-Link Adjustable switch point tolerances Speed-AP function for fast mounting and initialisation High visibility position

More information

Dimensions. Model Number. Electrical connection. Features. Pinout. Product information. Indicators/operating means OMT300-R201-IEP-IO-V1

Dimensions. Model Number. Electrical connection. Features. Pinout. Product information. Indicators/operating means OMT300-R201-IEP-IO-V1 Dimensions. 9.9 6 Model Number 6.7 Ref. 6. 5. 5.8 7 7.7.6 ø. 9 50 78.5 Receiver Emitter M x..7 sensor with -pin, M x connector Electrical connection Features Medium design with versatile mounting options

More information

POSITILT CAN SAE J1939 Output Specification

POSITILT CAN SAE J1939 Output Specification CAN SAE J1939 Output Specification Description Inclination sensor according to standard SAE J1939. Configuration of operating parameters by proprietary-a- Message (peer-to-peer connection). Process data

More information

CANopen IO X4 Fact sheet

CANopen IO X4 Fact sheet CANopen IO X4 Fact sheet Overview The CANopen IO X4 is a very compact and cost effective CANopen IO module featuring a high-density of industrial proven IO's. The module includes a CPU-core including the

More information

High and Low Frequency Radio Frequency Identification Systems (RFID)

High and Low Frequency Radio Frequency Identification Systems (RFID) High and Low Frequency Radio Frequency Identification Systems (RFID) Highlights High and low frequency systems networkable on ContriNet Low-frequency system All-metal housings, IP 68 and IP 69K Food safe

More information

Siemens Automation. SIMATIC RF200 IO-Link. SIMATIC Ident. RFID systems SIMATIC RF200 IO-Link. Introduction 1. Description 2.

Siemens Automation. SIMATIC RF200 IO-Link. SIMATIC Ident. RFID systems SIMATIC RF200 IO-Link. Introduction 1. Description 2. Introduction 1 Description 2 SIMATIC Ident RFID systems Operating Instructions System overview 3 Planning an RF200 IO-Link system 4 Commissioning and parameter assignment 5 Readers 6 Diagnostics 7 Technical

More information

Operating instructions Control monitor for temperature sensors TR /00 04/2011

Operating instructions Control monitor for temperature sensors TR /00 04/2011 Operating instructions Control monitor for temperature sensors TR7432 704773/00 04/20 Contents Preliminary note3. ymbols used 3 2 afety instructions 3 3 Functions and features 4 4 Function 4 4. Communication,

More information

RS485 MODBUS Module 8I8RO

RS485 MODBUS Module 8I8RO Expansion Module 8 digital inputs, 8 relay outputs Version 1.0 3.12.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device.

More information

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide BNI IOL302000K006 BNI IOL302000K006C01 BNI IOL302S01K006 BNI IOL302S01K006C01 IOLink 1.1 SensorHub / ActuatorHub User s Guide Content 1 Notes to the user 2 1.1 About this guide 2 1.2 Structure of the guide

More information

Safetinex Safety light curtains and access control barriers

Safetinex Safety light curtains and access control barriers Safetinex Safety light curtains and access control barriers HIGHLIGHTS Safety light curtains for hand and finger protection Access control barriers Safety relays Device and mirror columns Safetinex safety

More information

BNI IOL Z012. User s Guide

BNI IOL Z012. User s Guide BNI IOL-719-002-Z012 User s Guide Content 1 Notes for the user 3 1.1. Structure of the guide 3 1.2. Typographical Conventions 3 Enumerations 3 Actions 3 Syntax 3 Cross references 3 1.3. Symbols 3 1.4.

More information

Inclination sensors 2-dimensional, measuring range up to ±90

Inclination sensors 2-dimensional, measuring range up to ±90 Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R

More information

Type 2 light curtains for hand protection

Type 2 light curtains for hand protection General Catalog new INDUCTIVE SENSORS Full Inox Basic with IO-Link Full Inox Weld-Immune, M8 Full Inox C23, cubic with IO-Link High Temperature, 230 C (440 F) photoelectric SENSORS Contrast sensor with

More information

Electronic Level Switch ENS 3000

Electronic Level Switch ENS 3000 Electronic Level Switch ENS 3000 Description: The ENS 3000 is an electronic level switch with integrated display. The instrument has 1, 2 or 4 switching outputs and an analogue output signal is available

More information

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL 1 TABLE OF CONTENTS 1. MOUNTING INSTRUCTIONS 1.1 Standard DIN Rail mounting 1.2 Screw Mounting 2. FUSE REPLACEMENT 3. ASSEMBLING THE UNIT

More information

Optical distance sensors. Dimensioned drawing

Optical distance sensors. Dimensioned drawing Optical distance sensors Dimensioned drawing We reserve the right to make changes DS_ODS10L1_25M8L_en_50129321.fm en 04-2016/08 50129321 100 25000mm Measurement range up to 25000mm on HighGain foil Analog

More information

Fieldbus Appendix AnyBus-S FIPIO

Fieldbus Appendix AnyBus-S FIPIO Fieldbus Appendix AnyBus-S FIPIO DOC.ID: ABS-FIP-1 Rev. 1.00 HMS Industrial Networks Germany Japan Sweden U.S.A + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-2271 sales-ge@hms-networks.com

More information

SM9000. Magnetic-inductive flow meter. Made in Germany

SM9000. Magnetic-inductive flow meter. Made in Germany Made in Germany Application Application totaliser function; empty pipe detection; for industrial applications Installation connection to pipe by means of an adapter Media conductive liquids; water; hydrous

More information

Inclination sensors 1-dimensional, measuring range

Inclination sensors 1-dimensional, measuring range Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R

More information

Communication of passive RFID Reader and. FOX3-2G/3G/4G series via RS-232 serial link. and its use to identify RFID tags in

Communication of passive RFID Reader and. FOX3-2G/3G/4G series via RS-232 serial link. and its use to identify RFID tags in THIS DOCUMENT IS AVAILABLE AT HTTP://WWW.FALCOM.DE/ Communication of passive RFID Reader and FOX3-2G/3G/4G series via RS-232 serial link and its use to identify RFID tags in transportation and access management

More information

FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90

FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90 FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90 . 1 System overview............................................. 5 2 Sensor versions..............................................

More information

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide BNI IOL802102Z036 BNI IOL802102Z037 Smart Light User s Guide Content 1 Notes to the user 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical conventions 3 Enumerations 3 Actions 3 Syntax

More information

RFID A1 Module User Manual V1.183

RFID A1 Module User Manual V1.183 RFID A1 Module User Manual V1.183 Table of Contents 1 Introduction... 4 1.1 Device Overview... 4 1.2 Pinout... 5 1.3 Application... 6 2 Electrical Characteristics... 7 2.1 Test Conditions... 7 2.2 Absolute

More information

Powered Roller Controller for DeviceNet

Powered Roller Controller for DeviceNet PRC-620-090 TECHNICAL DATA Description The Holjeron Powered Roller Controller for use with DeviceNet has the features needed to handle up to four zones in a material handling system. A Brushless DC Powered

More information

Mounting and installation instructions Positioning of the ID tags with regard to the read/write head Installation of the ID tags in/on metal

Mounting and installation instructions Positioning of the ID tags with regard to the read/write head Installation of the ID tags in/on metal Mounting and installation instructions Positioning of the ID tags with regard to the read/write head Installation of the ID tags in/on metal UK ANT513 and E8037x 706120 / 00 07 / 2014 Contents 1 Preliminary

More information

Your Global Automation Partner. RU High End Ultrasonic Sensors. Operating instructions

Your Global Automation Partner. RU High End Ultrasonic Sensors. Operating instructions Your Global Automation Partner RU High End Ultrasonic Sensors Operating instructions Table of contents 2 Hans Turck GmbH & Co. KG T +49 (0)208 4952-0 F +49 (0)208 4952-264 more@turck.com www.turck.com

More information

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide Content 1 Notes 2 1.1. Struture of the guide 2 1.2. Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross references 2 1.3. Symbols

More information

Type 2 light curtains for hand protection

Type 2 light curtains for hand protection General Catalog new INDUCTIVE SENSORS Full Inox Basic with IO-Link Full Inox Weld-Immune, M8 Full Inox C23, cubic with IO-Link High Temperature, 230 C (440 F) photoelectric SENSORS Contrast sensor with

More information

RS 485 Mini Modbus 1AO

RS 485 Mini Modbus 1AO RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained

More information

hipecs-cio56 CANopen I/O module with PT100/1000 inputs

hipecs-cio56 CANopen I/O module with PT100/1000 inputs General The hipecs-cio56 is a powerful, low-cost CANopen module for temperature measuring via PT100/1000. According to demands 2-, 3- or 4-wire-connection is usable. Up to 4 channels using 2-wire-connection

More information

RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD

RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

Mounting and installation instructions Positioning of the ID tags with regard to the read/write head Installation of the ID tags in/on metal

Mounting and installation instructions Positioning of the ID tags with regard to the read/write head Installation of the ID tags in/on metal Mounting and installation instructions Positioning of the ID tags with regard to the read/write head Installation of the ID tags in/on metal UK ANT5 and E8036x 7069 / 00 0 / 03 Contents Preliminary note....

More information

TRW SERIAL TYPE Q RFID TRANSPONDER TECHNOLOGY DOC. 115-R6 PCB - BOX

TRW SERIAL TYPE Q RFID TRANSPONDER TECHNOLOGY DOC. 115-R6 PCB - BOX RFID TRANSPONDER TECHNOLOGY DOC. 115-R6 TRW SERIAL TYPE Q PCB BOX 1.0 FEATURES AND SPECIFICATIONS The TRW is a Front Side Serial Tag Reader/Writer with built-in Antenna. INTERFACE OPTIONS: TTL - RS232

More information

XXA18P1AM12 Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12

XXA18P1AM12 Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12 Characteristics Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12 Complementary Enclosure material Front material Supply voltage limits Function available [Sa] assured operating

More information