windream Client Installation windream GmbH, Bochum

Size: px
Start display at page:

Download "windream Client Installation windream GmbH, Bochum"

Transcription

1 windream Client Installation windream GmbH, Bochum

2 Copyright by windream GmbH / winrechte GmbH Wasserstr Bochum Issue: 06/ All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form (print, photocopy, or any other form) or by any means without the express written permission of windream GmbH / winrechte GmbH. Important Note All information and technical specifications in this book have been collected by the authors with great care. They cannot, however, either guarantee, take legal responsibility for or make any other warranty resulting from the use of this information. We would also like to point out that all software and hardware logos and names are the exclusive property of the Trademark, Brandname or Patent right holders. These are naturally protected by the appropriate laws and trade agreements.

3 Table of Contents i Table of Contents windream Client Installation 1 Introduction 1 windream client requirements 3 System requirements 3 System settings under Windows 9x 5 System settings under Windows NT 4.0, Windows 2000 and Windows XP 7 Executing the windream client installation 11 Client installation Standard 11 Client installation on Server - local Server share drive 11 Client installation on a terminal Server 11 Client setup installation modes 12 Client setup Starting the installation 14 Reboot 14 Installing the windream client (standard installation) 16 Launching the setup program 16 Welcome 16 Licence agreement 16 windream Info 17 windream system check 17 Select destination path 17 Settings database Server 17 Select program folder 17 Installation summary 17 windream setup complete 17 windream drive mapping 18 Starting windream 19 Update installation windream client 20 Client installation - local Server share drive 21 System requirements 21 Installing the Server drive 22 Welcome 22 Licence agreements 22 windream Info 22 windream components 22 windream system check 23 Select destination path 23 windream drive 23 VFS-Service logon account 24 Configuration database Server 25 Select program folder 26 Summary of the installation 26 windream setup complete 26 After the installation 27 Restrictions for the windream Clients 28

4 ii Table of Contents Installing the windream Client 30 windream components 30 Finishing the setup program and mapping the network drive 32 Client installation on a terminal server 35 System requirements 35 Installing the terminal Server network driver 36 Welcome 36 Licence agreements 36 windream Info 37 windream components 37 windream system check 37 Select destination path 38 VFS-service logon account 38 Settings database Server 39 Select program folder 40 Timestamp 40 Installation summary 41 windream setup complete 41 Connecting the windream drive 43 After the installation 43 Restrictions of the windream terminal Clients 44 Index 45

5 windream Client Installation 1 windream Client Installation Introduction The present documentation serves as a guideline for the installation of the windream client. Since windream version 3.6 has been released, the following installation types can be executed via the windream client setup: Client installation standard: The windream client is installed locally with the driver for the windream drive (VFS-driver) on every workstation computer (simulating a network drive). Client installation on server local server share drive : The driver for the windream drive (VFS-driver) is installed once and locally on a server which can be accessed by the clients (shared server drive). The windream client is installed with a filter driver (Windows 2000 or higher required) and without VFS-driver on the workstations. Client installation on a terminal server: In this case, the windream client and the driver for the windream drive (VFS-driver) are installed as terminal server network drivers on a terminal server. This way, the windream client application is available in the Windows terminal server environments as provided by Microsoft and in Citrix MetaFrame as well. Depending on the question which type of driver is installed for getting access to the windream drive respectively which of the mentioned installation types are to be executed, the windream client setup can be run in the standard mode or in an extended mode. Installation requirements and procedure The installation description first explains the steps to be executed before the installation of the windream client at the workstations. Depending on the operating system used (Windows 95/98, Windows NT 4.0, Windows 2000 or Windows XP), different system requirements are to be fulfilled, and additional components as well as specific system settings are required. The requirements to be fulfilled for the installation on a shared server or on a terminal server are explained with the description of the respective installation procedure. The respective installations are described in separate chapters. Client installation - standard p. 16 f. Client installation local server share drive p. 21 f.

6 2 windream Client Installation Client installation on a terminal server - p. 35 f. Update installation If you have already installed an earlier windream version, you can also execute an update installation via the setup routine. Note: A switch from a standard client with local server drive to a client with access to the server share incl. filter driver (or the other way round) is not possible via the setup program or via an update installation. In this case, the client application must be uninstalled and the computer must be rebooted. Then, you will have to select the components mentioned in the extended mode and within a new installation process. More documentations This documentation can also be found on the installation CD. The directory for the client installation also contains an HTML readme file named Readme.htm. This file allows to access all windream documentations provided with the installation CD.

7 windream Client Installation 3 windream client requirements We will now describe the requirements for the installation of the windream client. These requirements are valid for the installation of the windream workstations. The system requirements to be fulfilled for the installation of the server drive on a server share respectively the installation of a windream terminal server network driver are described separately. System requirements Consider the following minimum system requirements (recommended requirements in brackets) to ensure that the system will work properly. Computer RAM Free hard disk capacity Display Drive letter Hardware Pentium processor 133 MHZ (266 MHZ or higher) 64 MB At least 20 MB (50 MB) SVGA with 1024x768 resolution At least one free drive letter for the windream drive. Windows 9x / ME Windows 95 OS with Service Release 2, Windows 98 or Windows ME. Microsoft DCOM 1.3 and Microsoft DCOMConfig (for the DCOM-configuration under Windows 9x) must be installed. A reboot of the computer is required after the installation of DCOM. Microsoft WinSock 2 Update must be installed (Windows 95 only). Note: The Microsoft programs DCOM and DCOMConfig are not available on the windream installation CD. The entries MS DCOM 1.3 and DCOMConfig on the windream installation CD are linked to the download area of the supplier's homepage from which the Software can be downloaded. Windows NT 4.0 / 2000 / XP Windows NT 4.0 with Service Pack 6, Windows 2000 with Service Pack 4 or Windows XP Professional with Service Pack 1.

8 4 windream Client Installation Further requirements additional components Before installing the windream client application, it is required to install specific additional components. The windream installation CD contains the required components, which can be installed from the CD directly. Microsoft Internet Explorer version 5.01 or higher with Active Desktop must be installed. Microsoft Scripting Host 5.0 with Java/VB-support and Microsoft Script Control 5.0 must be installed (for executing scripts in windream). Optional components: Microsoft Management Console 1.2 must be installed, if administrative tasks with the windream Management Console shall be executed on this computer. Microsoft XML 3 (msxml3.dll version ) must be installed. This file can be found on the installation CD. On setup execution, the system will check whether MSXML has already been installed on the target system. If not, MSXML will have to be installed manually by executing the EXE-file. Adobe Acrobat Reader 4.0 or higher must be installed for displaying and printing the documentation. Note: If the installation of Microsoft Scripting Host should be required, this has to be executed before installing the windream client. If you install this component during the windream setup, answer the question displayed whether the computer shall be rebooted with No, reboot later. Otherwise, setup will be cancelled at this point. If the installation of Microsoft Script Control is required, this has to be executed before installing the windream client. Due to an error in the Script Control setup, the predefined path (for example C:\Program Files\Script Control) in the dialog box displayed cannot be changed via the Browse button, but only via a manual entry. Otherwise, the installation of the Script Control will be cancelled with an error. Thus, change the predefined path manually (for example C:\Program Files to D:\Programs). How to install the additional components 1. Insert the windream CD into your CD-ROM drive of your computer. If the autorun function is enabled, file Autorun.inf will be launched automatically.

9 windream Client Installation 5 2. Select menu item Installation on the start page. 3. Click menu item Additional components. 4. Select the menu item of the first additional component you want to install. 5. Repeat step 4 until all missing components have been installed. During the following setup process, the system will check whether the required components are available. If important components are missing, a respective message will be displayed in the System check dialog box. The setup process will be cancelled at this point and must be continued after having installed the missing components. System settings under Windows 9x After having installed the additional components, it is required to adjust the following system settings on Windows 9x workstations. Control panel network configuration TCP/IP must be configured. Adjust network access control on user level Before starting the setup, it is required to adjust the network access control on the user and group level. Depending on the current system configuration, meaning whether a domain controller is available or not, different procedures are necessary. Note: If the system should request the Windows installation CD when adjusting the access control, this question must be confirmed by clicking OK. As source directory, determine <drive letter>:\windows or <drive letter>:\windows\system, where Windows is your program directory (for example: C:\Windows). Usually, the requested files are available there.

10 6 windream Client Installation Figure 1: Adjusting the access control on user level Obtain list of users and groups from domain How to adjust the network access control on user level with an available domain controller 1. Start the Windows control panel (command Start>Settings>Control panel). 2. Double click the Network entry in the Windows control panel. 3. Select the Access Control tab page in the Network dialog box. 4. Enable the user level access control button. 5. In field Obtain list of users and groups from, enter the domain name under which the windream server operates. 6. Confirm your entry with OK. 7. Reboot your computer to make the changes become effective. or Logon to an NTdomain 1. In the Windows Explorer, select folder Network neighborhood or the respective desktop link. 2. Enable the Properties command from the context menu. 3. In dialog box Network, switch to tab page Configuration. 4. Click entry client for Microsoft networks. 5. Click the Properties button. 6. In dialog box Properties of client for Microsoft networks on tab page Common, enter the Windows NT domain of the windream server.

11 windream Client Installation 7 7. Confirm the entry with OK. 8. Reboot your computer to make the changes become effective. Note: The user and group list must be obtained from the same domain in which the selected windream server operates, or, if the windream server itself is the domain controller, from its domain. If you do not know the domain name, ask your responsible system administrator. The Windows NT domain must be the domain of the windream server. If the domain from which the user and group lists are obtained (domain 1) is different from that at which a logon is executed (domain 2), the user accounts of domain 1 must also be configured on domain 2. Configuration without domain controller How to adjust the network access control on user level without domain controller 1. Start the Windows control panel (command Start>Settings>Control panel). 2. Double click the Network entry in the control panel. 3. Click entry Network. 4. Select the Access control tab page in dialog box Network. 5. Switch the access control to user level. 6. Enter the name of the NT server on which the windream server operates. 7. Reboot your computer to make the settings become effective. Note: In order to be able to obtain DCOM-events from the windream server (only then will the windream indexing service be able to execute synchronous indexing for received jobs), the user account must be configured as a windream user on the windream server. System settings under Windows NT 4.0, Windows 2000 and Windows XP After the installation of the additional components, it is required to make the following system settings on Windows NT 4.0, 2000, or XP workstations. Note: The installing user must be a member of the administrators group to be able to install services and drivers. We recommend an installation under the "Administrator" ID.

12 8 windream Client Installation Identification of the connected NT workstation Before starting the windream setup, it is required to identify the connected NT workstations in the network. Depending on the current system configuration (meaning whether a domain controller is available or not), different procedures are necessary. Note: If a domain controller is available, the current client PC must possess an account in the NT domain from which the windream DMS Service obtains the windream authorization information. If no domain controller is used, the user account under which the installation is executed must be configured with the same name and password on the workstation computer and the Windows NT server and must be assigned to the administrators group. A windream user account must be configured on the workstation computer and on the windream NT server with the same name and password and must at least be assigned to one windream group. We will now describe how to switch the network identification of a client under Windows NT 4.0. This is executed under Windows 2000 or XP in the same way via the respective commands of the operating system.

13 windream Client Installation 9 How to identify the connected NT workstations with an available domain controller 1. Start the Windows control panel with command Start>Settings>Control panel. 2. Double click the network entry in the Windows control panel. 3. Select tab page Identification in the Network dialog box. 4. Enable the Change button to change the domain. 5. Enter the name of the domain which administers the rights for the windream server in field Domain.. 6. Confirm the entry with OK. 7. Reboot your computer to make the changes become effective. Figure 2: Identification of an NT workstation with domain How to identify the connected NT workstation without domain controller 1. Start the Windows control panel using command Start>Settings>Control panel. 2. Double click the Network entry in the Windows control panel. 3. Select tab page Identification in dialog box Network.

14 10 windream Client Installation 4. If necessary, enable button Change to change the workgroup. 5. In the dialog box for identification changes, enter the name of your workgroup in the respective field. 6. Confirm the entry with OK. 7. Reboot your computer to make the changes become effective.

15 windream Client Installation 11 Executing the windream client installation The following installations can be executed with windream client setup version 3.6 or higher: client installation standard, client installation on server local, shared server drive, client installation on a terminal server. In any case, the installation of the windream server must be executed separately via the respective setup program. Client installation Standard The windream server has been installed and is ready to operate. The windream client will be installed on the connected workstations with local client VFS-driver. For this installation type, you execute a standard client installation on the respective workstations (see also chapter "windream client installation - standard", p. 16 f.). Client installation on Server - local Server share drive The windream server has been installed and is ready to operate. The VFS-driver shall be installed as a local server share drive. These shares connect the workstations with a drive letter. Depending on the system configuration, the driver can be installed on the windream server itself or on one or several separate servers (server shares). For this installation type, you execute the client setup on these servers in the extended mode (see also chapter "Client installation - local server share drive ", p. 21 f.). Then, you execute the client setup in the extended mode on the connected workstations and install the windream client there without VFS-driver (see also chapter "Client installation - local server share drive ", p. 21 f.). Client installation on a terminal Server The windream server has been installed and is ready to operate. The windream client will be installed on a terminal server including the terminal server network driver (VFS-driver for terminal server). Depending on the system configuration, the windream client can be installed on one or several terminal servers. In this installation procedure, you execute the client setup on these servers in the extended mode (see also chapter "Client installation on a terminal server", p. 35).

16 12 windream Client Installation Client setup installation modes The client setup routine can be executed in two different modes: Standard, Extended. The selected mode depends on the question which driver type for access to the windream drive shall be installed and which of the client installations mentioned shall be executed. Driver type for VFS-driver The driver for the windream drive (VFS-driver) will either be installed locally on each workstation (emulation of a network drive), locally and once on a server which can be accessed by the clients (server share drive) or as terminal server network driver. Standard In this mode, the following components will be installed without the option of manual selections: DMS Connectivity, Shell and search extensions, Local network driver (standard). The VFS-driver will be installed locally as a network driver on the client. The network drive will be connected to the windream drive by configuring a manual network mapping via the Windows Explorer. Extended In this mode, a dialog for selecting the following components will be displayed: DMS Connectivity, Shell and search extensions, Local network driver (standard), Local server share drive, Access to server share (not for Windows 9x), terminal server network driver. windream components (extended mode) The components named DMS Connectivity and Shell and search extensions must always be installed on a windream client. Additionally, you must also select the desired component for the driver type to be installed.

17 windream Client Installation 13 Local network driver (standard) This component installs the local network driver on a client and corresponds to the standard client installation. Local server share drive This component installs the VFS-driver locally on a server. The drive will be shared. The associated workstations connect the share (e.g. \\Myserver\windream) with a free drive letter. A local VFSdriver installation is not required any more on these clients. The windream client will be installed via the client setup in the extended mode without selecting one of the driver components. Access to the server share (not Windows 9x) On Windows 2000 or XP workstations, the filter driver required for access to the server share (not Windows 9x) has to be installed in addition to the DMS and Shell / search extension components. Further information can be found in chapter "Access to the server share ", p. 31 and "Filter driver for access to the server share ", p. 31. Terminal server network driver This component installs the VFS network driver on a terminal server. Additionally, the client components for DMS connectivity and shell / search extensions will be installed on the terminal server. The drive will be shared. The share (e.g \\Windream\Objects) will be connected with a free drive letter by the Teminal client users. Note: If during the client setup a driver component is installed or updated, the computer must be rebooted after the installation. In other cases and as far as possible, a reboot will be avoided after a new installation. During update installations of clients without windream driver installations, a reboot will become necessary, if windream modules are still active. This reboot might be avoided under Windows NT, Windows 2000 and Windows XP, if all windream programs (Control Center, Search, DocView, etc.) and all Explorer functions incl. Desktop Explorers have been terminated (via the taskmanager). In this case, the setup program must be started from the taskmanager. A switch from a standard client with local server driver to a client installation with access to the server share including the driver is not possible via the setup program. For this, the client has to be uninstalled first and the computer has to be rebooted. Then, the components have to be selected in the extended mode, if a new installation is executed.

18 14 windream Client Installation Client setup Starting the installation If the Autostart of the CD-ROM drive has been enabled, the setup program will be started automatically. If it is disabled, start the setup program manually. setup with automatic CD-ROM start Starting the setup program manually How to start the setup program with automatic CD-ROM start 1. Insert the windream CD into the CD-ROM drive of your computer. 2. Click menu item Installation on the windream start page. 3. Select menu item windream installation and then Installation windream client. 4. Depending on the desired installation mode, select option windream client (standard) or windream client (extended). 5. Follow the instructions of the setup assistant. How to start the setup program manually 1. Insert the windream-cd into the CD-ROM drive of your computer. 2. In the Windows task bar, click Start. 3. Select menu item Programs>Windows-Explorer. 4. In the folder view, switch to the entry of the CD-ROM drive. 5. Double click file Start.exe in the Start folder. 6. Select menu item windream installation and the Installation windream client. 7. Depending on the desired installation mode, select either option windream client (standard) or windream client (extended). 6. Follow the instructions of the setup assistant. Note: You can also execute the setup program in the extended mode from the command line of an MS DOS window. Thus, open an MS DOS window and start the setup program with command line parameter /WM_EXT. For example E:\setup\windream\client\setup.exe /WM_EXT Reboot If the setup program asks for a reboot at the end of the installation procedure, a new login must be executed after the reboot under the user ID with which the installation has been executed (e.g. administrator).

19 windream Client Installation 15 Then, the setup program will start automatically again to execute the required registrations and configurations and to connect the windream network drive with a drive letter. If the setup program does not start automatically after the reboot, a reason may be that you have started the setup program from a network drive to which there has not been a connection so far. In this case, please start the windream client setup manually again. You will then receive a respective message. If no driver component is selected in the client setup, a reboot will be avoided as far as possible.

20 16 windream Client Installation Installing the windream client (standard installation) Before starting the windream setup, close all active applications to be able to install windream correctly. Note: The windream client and the windream server installation may not be executed on the same computer. Launching the setup program Start the setup program from the installation CD. See also chapter "Client setup starting the installation", p. 14. setup with automatical CD- ROM start Starting setup manually How to start the setup with automatical CD-ROM start 8. Insert the windream-cd into the CD-ROM drive of your computer. 9. Click menu item Installation on the windream start page. 10. Select menu item windream client. 11. Follow the instructions of the setup assistant. How to start the setup manually 7. Insert the windream-cd into the CD-ROM drive of your computer. 8. In the Windows taskbar, click Start. 9. Select menu item Programs>Windows-Explorer. 10. In the folder view, switch to the CD-ROM drive. 11. Start the windream setup with a double click on the program file named Start.exe in folder Start. 12. Click menu item Installation on the windream start page. 13. Select menu item windream client. 14. Follow the instructions of the setup assistant. Welcome After having started the windream setup, a setup assistant will guide you through the required installation steps. Licence agreement With the installation of windream, you confirm the licence agreements.

21 windream Client Installation 17 windream Info This dialog displays information on the system requirements of the windream installation. Before continuing the installation, please check whether the requirements are fulfilled. If not, cancel the installation at this point and install the missing components. windream system check The windream system check will check the system configuration and the installation requirements. If required additional components are missing or if the system settings are incorrect, a respective message will be displayed in the dialog box. In this case, the setup cannot be continued. Cancel the installation. If necessary, install the required components and adjust the required settings. Then, start the setup again. Select destination path In this dialog box, you enter the destination path for the installation of windream. Apply the preselected target folder or determine a different one via the Browse button. Settings database Server Enter the name and the port of the server on which the windream DMS-Service is installed. The fields are preset, and usually you can apply the preselection. If you are not sure, ask your administrator. Select program folder In this dialog box, enter a name for the folder under which the windream icon will be displayed in the start menu. Installation summary In the installation summary, all settings will be displayed which you have made during the installation process. Before starting, you will be able to change the settings by clicking the Back button. Confirm the current settings with Next. The program files will be copied into the destination directory. windream setup complete Setup will inform you that the installation has been completed successfully with this message.

22 18 windream Client Installation Computer reboot A reboot might become necessary after the installation to enable registrations and configuration updates. Thus, the setup program will once again be started after the reboot to update the Registry and to connect the network. If the setup cannot be started automatically after reboot, a respective message will be displayed. In this case, start the setup manually once again (see chapter "How to start the setup program manually", page 16). Note: When rebooting the computer, you will have to log on to the system with the same user account which you used for installing the windream client. After having registered the windream Services, you can log on as windream user (not administrator). This user must also connect (map) the windream drive with a drive letter. windream drive mapping After having installed the windream client successfully, it is required to map the windream drive with a free drive letter on the client. The folder to be mapped can be found at \\windream\objects under Network neighborhood>complete network>windream. You can automatically map the drive after having completed the setup and after having rebooted the computer, or you can map the drive manually later. How to map the windream drive automatically 1. Confirm the question on mapping the windream drive with Yes. 2. In dialog box Map network drive, select the drive letter with which you want to map the share (\\windream\objects). 3. Enable the checkbox for restoring the mapping on logon. 4. Confirm the entry with OK. How to map the windream drive manually 1. Open the Windows Explorer. 2. Open command Map network drive of the respective tab page from the Specials menu.

23 windream Client Installation In dialog box Map network drive, select the drive letter with which you want to connect the share (\\windream\objects). 3. Enter the folder with which the mapping shall be connected in the Folder field. The release can be found under Network neighborhood>complete network>windream. 4. Enable the checkmark for restoring the mapping on logon. 5. Confirm the entries with OK. Starting windream After having executed the windream installation successfully, you will now be able to start windream for the first time. Now, the drivers will be activated, and the client computer will be connected to the windream server. How to start windream 1. Open the windream Control Center with a right mouse click on the windream icon in the system tray. 2. Start the VFS-Service using command VFS Service>Start of the windream Control Center.

24 20 windream Client Installation Update installation windream client windream offers to execute an update installation from a previous to the current version. Note: If a previous windream version has already been installed on the target system, only an update installation can be executed. A complete new installation will only be possible after a complete uninstallation of the previous version. How to execute an update installation 1. Close all windream services. 2. Launch the windream client setup from the installation CD (call setup.exe). 3. Confirm the question whether an update shall be executed with Yes. 4. Reboot your computer after the update installation (see also chapter "Computer reboot", page 18). Note: After an update, it is required to map the windream drive with a free drive letter (see chapter "windream drive mapping", page 18).

25 windream Client Installation 21 Client installation - local Server share drive In order to install the server share drive, you first install the VFS-driver on the windream server (not recommended) or on another server. Then, you install the windream client on the connected workstations. The share (e.g.. \\Myserver\windream) must then be connected with a free drive letter on the windream client computers (see also chapter "Installing the windream client", p. 30). Both installations are executed via the client setup program in the extended mode. See also chapter "Client setup installation modes ", p. 12. The installation of the windream server is executed via the windream server setup either on a separate computer or on the shared server. System requirements The requirements which must be fulfilled for the installation of the windream client on the workstation computers can be found in chapter "windream client requirements", p. 3. The following requirements are valid for the shared server. System requirements for the shared server Windows NT 4.0 with Service Pack 6 or Windows 2000 server with Service Pack 3. Note: We do not recommend to install the driver on the windream server, but on one or several separate (shared) servers. Possible problems of the VFS-driver may then lead to problems with the shared servers, but would not affect the windream server itself. Thus, we recommend to choose a configuration similar to that explained in the following example:

26 22 windream Client Installation Figure 3: Configuration of a windream installation for a server share drive In the following description, the shared server will be named as SHARESRV_1 and the windream server as WMDMSSRV. Installing the Server drive Start the setup program from the installation CD on the shared server in the extended mode. See also chapter "Client setup starting the installation", p. 14. Welcome After you have started the setup program, the installation assistant will guide you through the required installation steps. Licence agreements With the installation, you confirm the licence agreements. windream Info Before you continue the installation, check whether the system requirements are fulfilled. windream components Select the following components in this dialog box:

27 windream Client Installation 23 DMS connectivity Local server drive with share. Figure 4: windream components for the installation of the server drive with share Further information can be found in chapter "windream components (extended mode)", p. 12. windream system check The windream system check will check the system configuration and the installation requirements. If required components are missing or if the system settings are incorrect, a respective message will be displayed in the dialog box. In this case, the setup program cannot be continued. Cancel the installation. If necessary, install the missing components and correct the system settings. Then, start the setup again. Select destination path In this dialog box, you determine the target folder for the installation of windream. Use the folder which the system suggests or determine another folder via the Browse button. windream drive Here, you determine a drive letter under which the windream share will be created.

28 24 windream Client Installation Figure 5: windream drive for the installation of the server drive with share VFS-Service logon account Here, you enter the user-id under which the windream VFS-service will operate on the shared server. This user account must already exist before executing the setup program. We recommend to use the ID of the windream mainuser. Figure 6: VFS-Service logon account for the installation of the server drive with share If the windream DMS-server has been configured with a mainuser whose account has been created on a domain (e.g.

29 windream Client Installation 25 MYDOMAIN\windream), this domain user must also be determined on the server share. If the windream DMS-server is configured with a mainuser account which has been created locally on the windream server (e.g. WMDMSSRV\windream), this user account must also be created locally on the server share (e.g. SHARESRV_1\windream). In this case, you enter the ID of the local user during the setup on the server share. The user determined (windream mainuser) will be added to the group of local administrators by the setup program, and the following system rights will be assigned: System right SeBatchLogonRight SeCreatePermanentPrivilege SeCreateTokenPrivilege SeLoadDriverPrivilege SeServiceLogonRight SeTcbPrivilege Logon as batch processing job Creating permanently shared objects Creating a token object Loading and removing device drivers Logon as service Table 1: System rights of the windream mainuser on the server share Acting as a part of the operating system Configuration database Server Here, you enter the name and the port of the server on which the windream server is installed. The fields are preset, and generally - you can apply the presettings.

30 26 windream Client Installation Figure 7: Settings database server for the installation of the server drive with share Select program folder In this field, you enter a name for the program folder under which the windream icon will be displayed in the Start menu. Summary of the installation Here, all settings you have made during the installation processs will be displayed as a summary. You can still change the settings by clicking the Back button. Confirm the current settings with Next. The program files will be copied into the destination directory. windream setup complete The setup program indicates that the installation is complete with this dialog box. Computer reboot After having completed the setup procedure, a reboot is required for refreshing and updating the configuration. Thus, the setup program will once again be started after the reboot to update the Registry and the configuration. A respective message will be displayed, if the setup program cannot be started after the reboot automatically. This may for example happen, if

31 windream Client Installation 27 you have launched the setup program from a network drive to which there was no connection at the time of the reboot. In this case, start the windream setup manually again (see also chapter "Client setup starting the installation", p. 14). You can start the setup in the standard mode (see chapter "Client setup installation modes", p. 12). Note: During the computer reboot, you will have to log on with the same user account at the system under which you have also executed the installation (e.g. under the administrator-id). Starting the VFS-service After the installation, the VFS-service can be started after having confirmed a respective message, and the start type can be set to Automatical. Figure 8: Starting the VFS-Service and setting the start type After the installation After the installation, you can change the preset name on the server share or adjust the number of threads to be started to the number of users who will access the drive (see chapter "The local server drive on the server share ", p. 27 and "Determining the number of threads for access to the drive ", p. 28). Then, the windream client installation has to be executed on the connected client workstations (see chapter "Installing the windream client", p. 30). The local server drive on the server share After the second start of the setup program, a local drive named "windream" occurs under the drive letter determined in the setup program. This drive cannot be accessed locally on the server. The windream users known on the DMS-server can now map the share SHARESRV_1\windream on the workstations (map network drive). By default, the share will be installed under the name "windream" and with a comment "windream server Share" on the shared server. These designators are determined via respective entries in the Registry and

32 28 windream Client Installation can be changed there. Before, you must close the windream VFSservice. Changing the share designators in the Registry Under key HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\ Services\vfsdrv\Parameters\ you can change the name and the comment of the share. Registry entry Share name: Comment: ShareName of type STRING ShareComment of type STRING Value windream windream server Share After having changed the Registry entries, the server must be rebooted. Determining the number of threads for access to the drive By default, a number of threads is preset via an entry in the Registry which can be started as a maximum. Generally, one thread per loggedin user is used. If more users log on to the drive than have been determined in entry MaxThreads, several users will share one thread which may lead to a performance loss. To avoid this, you can adjust the number of threads to be started. A value up to 256 is allowed. HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\ Services\vfsdrv\Devices\VfsccomDevice\1 MaxThreads=Dword: The preset number of threads will be created directly on the driver side and on the service side as well, when the VFS-service is started. We recommend to calculate not more than two users per thread. If more users shall work with the drive, we recommend to configure a further server share. After having made the changes in the Registry, the windream VFSservice must be closed and started again. Restrictions for the windream Clients The following restrictions are valid for the connected clients: 1. Indices of deleted, renamed or moved files can "land" (meaning they can be transferred) on new files during Explorer operations. 2. No index events will be created for the files mentioned under 1., meaning that the client service will display no index dialog.

33 windream Client Installation 29 Explanation windream clients which address the share without local driver can browse in the windream drive and create and change files. Changes which have been made via the Windows Explorer underlie the following restrictions: On a standard client, so called "floating indices" will be created on deleting, renaming or moving operations of applications (except Explorer), which will "land" again when a document is created with the same name. In the same way, indices can also land on a second document, if the first one is renamed or deleted. This will not happen after respective Explorer operations on a standard client. In contrast to standard client installations, an installation with server share cannot detect which client process executes an action. Due to this fact, Explorer and other applications (e.g Microsoft Word) cannot be differentiated from each other. A consequence is that these indices will also land again on Explorer operations. Further on, no index events will be created by the windream server for documents which have received floating indices, and no indexing dialog will be displayed. A "landing" will only happen, if the same client session executes this action. The "landing" of floating indices can be limited on the windream DMS-server by setting a timeout value in the Registry. Under key HKEY_LOCAL_MACHINE\SOFTWARE\A.I.S. GmbH\windream\3.6\Database there is an entry named TTSTimeout of type DWORD, via which you can set the timeout value: TTSTimeout value = 0: no timeout (default) TTSTimeout value > 0: timeout in seconds. Warning: The setting of a timeout >0 may result in a loss of index information when editing documents e.g. with MS Office applications. The applications save new files partly in temporary files, delete the original file (with index data) and rename the temporary file into the original name, and the indices "land" again. If the timeoout value has been set lower than the time the office applications need between deleting the original file and the renaming process of the temporary file, the original indices will be lost.

34 30 windream Client Installation Note: The restrictions mentioned can be avoided under Windows 2000 and XP. Thus, the filter driver named "Access to server share" will be installed on the windream clients (see chapter "Installing the windream client", p. 30). Installing the windream Client Now, you execute the windream client setup program on the workstations. The setup program has been described in chapter "Installing the windream client" (standard installation)", p. 16. We will now describe those dialogs and settings which diverge from the standard installation. Start the setup program in the extended mode to install the client without local VFS-driver (see also chapter "Client setup Starting the installation ", p. 14). In the windream components dialog box, you select the components to be installed. Further information concerning the respective components can be found in chapter "windream components (extended mode)", p. 12. windream components Select the following components: DMS connectivity, Shell- and find extensions and (if required) server share access (not Windows 9x).

35 windream Client Installation 31 Figure 9: windream components client with access to server share server share access With the option named server share access (not Windows 9x) a filter driver can be installed (depending on the operating system) with which the restrictions described under "Restrictions for the windream clients", p. 28 can be avoided. System requirements for the filter driver Windows 2000 Professional with Service Pack 3 or Windows XP Professional with Service Pack 1. The operating systems Windows NT 4, 95, 98, and ME are not supported. Filter driver for server share access The filter driver transfers the required process information to the server share so that a differentiation between Explorer and the other applications is possible again. Note: A switch from a standard client with local serverdrive drivers to a client with access to the server share incl. the filter driver is not possible via the setup program. For this, the client must be uninstalled and the computer must be rebooted. Then, the components mentioned must be selected for a new installation in the extended mode.

36 32 windream Client Installation Restrictions After the installation of the filter driver "Access to server share", a device which can be started manually named windream VFS Filter driver is displayed in the device manager. (The viewing type must include hidden devices. The driver can be found under entry Non-PnP-driver and is named "windream VFS Filter driver"). After having executed the windream client setup, the driver is set to being started on demand (tab page Driver from the driver Properties), because on the one hand, performance limitations (5-10 %) in file system operations are to be expected, as for transferring the process information additional system calls are executed and network traffic is created. On the other hand, enabling the automatic start type may lead to problems like a system crash. Due to this reason, we do not recommend to change the settings. Instead, a manual start of the driver can be entered in the local Registry. Under key [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows \CurrentVersion\Run] the following entry can be created: WindreamLMFilter=net start LMFilter In order to enable the driver to be started, the logged-on user must be a member of the Windows NT group named Mainusers. Otherwise, access will be denied. If the driver shall also be started for users who are not members of the group of mainusers, a respective process can be defined in the task manager. Thus, log in under the local administrator ID first. Then, create a scheduled task in the task manager, which executes the "net start LMFilter" command under the local administrator account during the logon process (tab page Schedule of the task properties, execute task on logon). Finishing the setup program and mapping the network drive After having completed the setup program, a reboot might become necessary for refreshing and completing the configuration. Thus, the setup program will be launched once again after the reboot (in standard mode) to update the Registry and to connect the share (see chapter "Client setup installation modes", p. 12).

37 windream Client Installation 33 Start windream Control Center now Enable this option, if the Control Center shall be started automatically after having completed the setup procedure. You can also start the windream Control Center manually from the Start menu any time you want (e.g. via command Start>Programs>windream>windream Control Center). Figure 10: Starting the windream Control Center Reboot A respective message will be displayed, if the setup program cannot be started automatically again. In this case, start the windream setup program once again manually (see also chapter "Client setup Starting the installation", p. 14). Note: When rebooting your computer, you will have to log on to the system under the same user account under which you have also executed the installation of the windream client. After having registered the windream services, a logon can be executed under the ID of a windream user (not administrator). This user must also connect the share with a drive letter. Connecting the windream drive After having installed windream successfully, you will still have to map the share (the server drive, e.g. \\Myserver\windream) with a free drive letter on the client.

38 34 windream Client Installation Figure 11: Mapping the windream drive You will be able to map the drive automatically after having completed the setup and after the reboot or to map the drive manually later (see also chapter "Mapping the windream drive ", p. 18).

39 windream Client Installation 35 Client installation on a terminal server In order to install windream on a terminal server, you install the windream client including the terminal server network drivers on a terminal server. The installation is executed via the client setup in the extended mode (see also chapter "Client setup installation modes", p. 12. The share (e.g. \\Windream\Objects) will then be mapped by the terminal server users on the terminal clients with a free drive letter (Map network drive). The installation of the windream server is executed via the windream server setup on a separate computer (windream server). System requirements The requirements which are valid for the installation of the windream client on the workstations have been described in chapter "windream client requirements ", p. 3. System requirements for terminal server network driver Windows 2000 server Service Pack 3 and Microsoft Windows terminal server or Citrix MetaFrame in installation mode. Note: We urgently recommend not to install the windream server on the terminal server, but on a separate computer. Additionally, a separate server should exist as a Domain Controller which administers the user and group profiles. Thus, you should select a system configuration like that presented in the following example:

40 36 windream Client Installation Figure 12: Configuration of a windream installation in terminal server environments In the following description, the terminal server will be named as TERMSRV_1 and the windream server as WMDMSSRV. Installing the terminal Server network driver Launch the setup program on the terminal server from the installation CD in the extended mode. See also chapter "Client setup Starting the installation", p. 14. Attention: Ensure that the terminal server operates in the installation mode. If required, change the mode before the installation via command change user /install from a command line of a DOS prompt. Via command change user /query you can request the current mode in advance. Welcome After having started the setup program, the setup assistent will guide you through the installation steps. Licence agreements with the installation, you confirm the licence agreements.

41 windream Client Installation 37 windream Info Before continuing the installation, please check whether the system requirements are fulfilled. windream components In this dialog box, you select the following components: DMS Connectivity, Shell- and find extensions, terminal server network drive. Figure 13: windream components for the installation of the terminal server Further information on the respective components can be found in chapter "windream components (extended mode)", p. 12. windream system check The windream system check checks the system configurations and the installation requirements. If required additional components are missing or if the system settings are incorrect, a respective message will be displayed in the dialog box. In this case, the setup program cannot be continued. Cancel the installation. If necessary, install the missing components and correct the systerm settings. The, start the setup program again.

42 38 windream Client Installation Select destination path In this dialog box, you enter the destination folder for the installation of windream. Apply the suggested folder or choose another one via the Browse button. Attention: If several terminal servers are used on which windream is installed, please urgently ensure that the same installation path is set on all servers. VFS-service logon account Here, you enter the user-id under which the windream VFS-service will operate on the terminal server. This user account must exist before executing the setup program. We recommend to use the ID of the windream mainuser. Figure 14: Entering the ID of the windream mainuser during the installation of the terminal server While executing the setup program, the windream mainuser must be determined, under whose ID the windream VFS-service will operate on the terminal server. This user account must already exist before executing the setup program. If the windream DMS-server has been configured with a mainuser whose account has been created on a domain (e.g. MYDOMAIN\windream), this domain user must also be determined on the terminal server.

43 windream Client Installation 39 If the windream DMS-server is configured with a mainuser account which has been created locally on the windream server (e.g. WMDMSSRV_1\windream), this user account must also be created locally on the terminal server (e.g. TERMSRV_1\windream). In this case, you enter the ID of this local user on the terminal server when executing the setup program. The user determined (windream mainuser) will be added to the group of local administrators by the setup program, and the following system rights will be assigned: System right SeBatchLogonRight SeCreatePermanentPrivilege SeCreateTokenPrivilege SeLoadDriverPrivilege SeServiceLogonRight SeTcbPrivilege Logon as batch processing job Creating permanently shared objects Creating a token object Loading and removing device drivers Logon as service Acting as part of the operating system Table 2: System rights of the windream mainuser on the terminal server Note: After having completed the installation, please check in the local security rules of the system settings (e.g. via command Programs>Administration) whether the rights have been set respectively. If this is not true, you will have to assign the rights manually there. Settings database Server Here, you enter the name and the port of the server on which the windream DMS-service is installed. The fields are preset and generally you can apply the presettings.

44 40 windream Client Installation Figure 15: server name of the windream server and port of the TCP-service in a terminal server installation Select program folder In the Program folder field, you enter a name for the folder under which the windream icon will be displayed in the Start menu. Timestamp A timestamp will be displayed in this dialog box. This timestamp is required for synchronisation in different terminal server installations. If several terminal servers are used on which windream shall be installed the same timestamp must be entered in the Registry on all servers. Otherwise, user-defined settings will always be overwritten by default settings. If the setup program is executed for the first time on the first terminal server, please copy the timestamp displayed so that you can use it for the following setups on further terminal servers.

45 windream Client Installation 41 Figure 16: Timestamp during the terminal server installation If this is already an installation on a further terminal server, please type the timestamp of the first installation into the input field. You can check the timestamp in the Registry on the different terminal servers: HKEY_LOCAL_MACHINE\SOFTWARE\A.I.S. GmbH\windream\3.6\setup Under this key, the timestamp is entered as a character string with the following format: Installed = YYYYMMDDHHMMSS Note: This timestamp entry must be identical on all terminal servers before a user logs in there. Installation summary In a summary, all settings will be displayed which you have made during the setup routine. You can change settings by clicking Back. Confirm the current settings with Next. The program files will be copied to the destination directory. windream setup complete The setup program informs you that the installation process has been completed with this dialog box.

46 42 windream Client Installation Reboot By default, the setup program requires a reboot. After the reboot, you will have to log on with the same user account with which you have also executed the installation procedure of the windream terminal server driver. Then, you start the setup program once again manually to execute the required registrations and configurations (see also chapter "Client setup Starting the installation", p. 14). you can start the setup program in standard mode (see also chapter "Client setup Installation modes", p. 12). Note: When rebooting the computer, you will have to log on with the same user account which you also used for installing the windream client. terminal server must run in installation mode Please ensure that the terminal server runs in the installation mode. If this is not true, respective messages will be displayed. The setup program will be cancelled at this point. Change the mode via command change user /install from a command line of the MS DOS prompt. Then, start the setup again to execute the required registrations and configurations. Starting the VFS-service After the installation, the VFS-service can be started after having confirmed a respective message, and the start type can be set to Automatic. Figure 17: Starting the VFS-service and setting the start type The setup procedure is complete now. The terminal server users will now connect to the share drive (windream drive) with a free drive letter at the associated terminal clients. After the network drive has been mapped, the terminal client users who are entered as windream users can work with windream.

47 windream Client Installation 43 Connecting the windream drive After the second start of the setup program, you can find the share \\Windream\\Objects in the network neighborhood under Network neighborhood>complete network >windream. Log on as terminal client user on a connected client and map the windream drive (command Specials>Map network). Figure 18: Mapping the windream drive terminal client You can now work with windream. Further information on the application can be found in the windream documentations. Note: The share must not be mapped with a drive letter by an administrator who is logged in at the console locally. The mapping may exclusively be executed by real terminal client users, if required by a logon script. After the installation After the installation, the number of threads to be started can be adjusted to the number of users who will access the drive (see also chapter "Determining the number of threads for access to the drive", p. 43). Determining the number of threads for access to the drive By default, a number of threads which can be started as a maximum has been preset via a Registry entry. Generally, one thread for each logged in user is used. If more users log on to the drive than have been

windream Solo Installation Guide windream GmbH, Bochum

windream Solo Installation Guide windream GmbH, Bochum windream Solo Installation Guide windream GmbH, Bochum Copyright 2003-2005 by windream GmbH / winrechte GmbH Wasserstr. 219 44799 Bochum Issue: 05/05-1.0.0.5 All rights reserved. No part of the contents

More information

windream web portal pro Server Installation windream GmbH, Bochum

windream web portal pro Server Installation windream GmbH, Bochum windream web portal pro Server Installation windream GmbH, Bochum Copyright 2001 2005 by windream GmbH / winrechte GmbH Wasserstr. 219 44799 Bochum Issue: 04/2005 3.6.0.0 All rights reserved. No part of

More information

windream Exchange 3.0 Manual windream GmbH, Bochum

windream Exchange 3.0 Manual windream GmbH, Bochum windream Exchange 3.0 Manual windream GmbH, Bochum Copyright 2004 by windream GmbH / winrechte GmbH Wasserstr. 219 44799 Bochum Issue: 09/2004 3.0.0.2 All rights reserved. No part of the contents of this

More information

windream 4.5 User Guide windream GmbH, Bochum

windream 4.5 User Guide windream GmbH, Bochum windream 4.5 User Guide windream GmbH, Bochum Copyright 2001 2009 by windream GmbH Wasserstr.219 44799 Bochum Issue: 01/09-4.5.0.1 All rights reserved. No part of the contents of this book may be reproduced

More information

windream 3.6 User Manual windream GmbH, Bochum

windream 3.6 User Manual windream GmbH, Bochum windream 3.6 User Manual windream GmbH, Bochum Copyright 2001 2005 by windream GmbH / winrechte GmbH Wasserstr.219 44799 Bochum Issue: 01/05 3.6.1.4 All rights reserved. No part of the contents of this

More information

windream 4.0 Administration Guide windream GmbH, Bochum

windream 4.0 Administration Guide windream GmbH, Bochum windream 4.0 Administration Guide windream GmbH, Bochum Copyright 2001 2007 by windream GmbH Wasserstr.219 44799 Bochum Issue: 08/07-4.0.0.2 All rights reserved. No part of the contents of this book may

More information

Release Notes and Known Issues

Release Notes and Known Issues windream 6.0 Release Notes and Known Issues windream GmbH, Bochum Copyright 2015 by windream GmbH Wasserstr.219 44799 Bochum Issue: 07/15-6.0.0.8 (4) All rights reserved. No part of the contents of this

More information

windream 5.5 What's New? windream GmbH, Bochum

windream 5.5 What's New? windream GmbH, Bochum windream 5.5 What's New? windream GmbH, Bochum Copyright 2013 by windream GmbH Wasserstr.219 44799 Bochum Issue: 08/13 5.5.0.2 All rights reserved. No part of the contents of this book may be reproduced

More information

Trace Debug Tools Version 1.2 Installation Guide

Trace Debug Tools Version 1.2 Installation Guide Trace Debug Tools Version 1.2 Installation Guide Copyright 2000-2002 ARM Limited. All rights reserved. Proprietary Notice Words and logos marked with or are registered trademarks or trademarks owned by

More information

Mercury WinRunner. Installation Guide Version 9.2. Document Release Date: February 26, 2007

Mercury WinRunner. Installation Guide Version 9.2. Document Release Date: February 26, 2007 Mercury WinRunner Installation Guide Version 9.2 Document Release Date: February 26, 2007 Mercury WinRunner Installation Guide, Version 9.2 This document, and the accompanying software and other documentation,

More information

Relativity Designer Installation Guide

Relativity Designer Installation Guide Liant Software Corporation Relativity Designer Installation Guide Version 5 Copyright 1994-2003 by Liant Software Corporation. All rights reserved. Printed in U.S.A. No part of this publication may be

More information

Galileo Desktop SM 2.1. Installation Guide

Galileo Desktop SM 2.1. Installation Guide Galileo Desktop SM 2.1 Installation Guide Galileo Desktop SM 2.0 Installation Guide, January 2007 i 2008 Galileo International, L.L.C. All rights reserved. Information in this document is subject to change

More information

ChromQuest 4.2 Chromatography Data System

ChromQuest 4.2 Chromatography Data System ChromQuest 4.2 Chromatography Data System Installation Guide CHROM-97200 Revision A April 2005 2006 Thermo Electron Corporation. All rights reserved. Surveyor is a registered trademark and ChromQuest is

More information

TIE1.80InstallationGuideUK

TIE1.80InstallationGuideUK Installation Guide 112206 2006 Blackbaud, Inc. This publication, or any part thereof, may not be reproduced or transmitted in any form or by any means, electronic, or mechanical, including photocopying,

More information

Mercury QuickTest Professional. Installation Guide Version 9.0

Mercury QuickTest Professional. Installation Guide Version 9.0 Mercury QuickTest Professional Installation Guide Version 9.0 Mercury QuickTest Professional Installation Guide, Version 9.0 This manual, and the accompanying software and other documentation, is protected

More information

System Management Guide Version 7.4a

System Management Guide Version 7.4a Epicor Active Planner Open Integration System Management Guide Version 7.4a Copyright Trademarks Program copyright 1995-2011 Sage Software, Inc. This work and the computer programs to which it relates

More information

windream 6.5 What s New? windream GmbH, Bochum

windream 6.5 What s New? windream GmbH, Bochum windream 6.5 What s New? windream GmbH, Bochum windream GmbH Wasserstr.219 44799 Bochum Issue: 11/2016 6.5.0.0 All rights reserved. No part of the contents of this book may be reproduced or transmitted

More information

FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory Installation & Administration Guide Version

FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory Installation & Administration Guide Version FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory Installation & Administration Guide Version 2011.1 2011 Sage Software, Inc. All rights reserved. Portions Copyrighted 1991-2001 by ianywhere

More information

DesignPro Tools for Xerox Elixir Technologies Corporation. All rights reserved.

DesignPro Tools for Xerox Elixir Technologies Corporation. All rights reserved. Follow the Crop Marks DesignPro Tools for Xerox Getting Started Guide C 1998-2008 Elixir Technologies Corporation. All rights reserved. Elixir Technologies Corporation 721 East Main Street Ventura, CA

More information

Océ Account Center. User manual

Océ Account Center. User manual Océ Account Center User manual Océ-Technologies B.V. Copyright 2004, Océ-Technologies B.V. Venlo, The Netherlands All rights reserved. No part of this work may be reproduced, copied, adapted, or transmitted

More information

Installing TimeMap User Guide

Installing TimeMap User Guide Installing TimeMap User Guide TimeMap, Version 5.1 System Requirements Installing TimeMap Converting Timelines Updating TimeMap Versions TimeMap Installation Guide No part of this work may be reproduced

More information

Read Naturally SE Software Guide. Version 2.0

Read Naturally SE Software Guide. Version 2.0 Read Naturally SE Software Guide Version 2.0 Under the terms of the Read Naturally Software Edition License Agreement, you have permission to use only the levels you purchased with the number of users

More information

Copyright Jetro Platforms, Ltd. All rights reserved.

Copyright Jetro Platforms, Ltd. All rights reserved. Important Notice Copyright 2001 2009 Jetro Platforms, Ltd. All rights reserved. This document is furnished by Jetro Platforms for information purposes only to licensed users of the Jetro COCKPIT product.

More information

System Management Guide Version 7.52

System Management Guide Version 7.52 Sage 500 Budgeting and Planning 2013 System Management Guide Version 7.52 Copyright Trademarks Program copyright 1995-2013 Sage Software, Inc. This work and the computer programs to which it relates are

More information

HP QuickTest Professional

HP QuickTest Professional HP QuickTest Professional Software Version: 10.00 Installation Guide Manufacturing Part Number: T6513-90038 Document Release Date: January 2009 Software Release Date: January 2009 Legal Notices Warranty

More information

NCD ThinPATH PC Installation Guide and Release Notes

NCD ThinPATH PC Installation Guide and Release Notes NCD ThinPATH PC Installation Guide and Release s Copyright Copyright 2001 by Network Computing Devices, Inc. (NCD).The information contained in this document is subject to change without notice. Network

More information

Galileo Print Manager Installation Guide

Galileo Print Manager Installation Guide Galileo Print Manager Installation Guide 24 November 2003 Copyright 2003 Galileo International. All rights reserved. Information in this document is subject to change without notice. The software described

More information

Administrator for Enterprise Clients: User s Guide. Second Edition

Administrator for Enterprise Clients: User s Guide. Second Edition Administrator for Enterprise Clients: User s Guide Second Edition The correct bibliographic citation for this manual is as follows: SAS Institute Inc. 2002. Administrator for Enterprise Clients: User s

More information

Quick KVM 1.1. User s Guide. ClearCube Technology, Inc.

Quick KVM 1.1. User s Guide. ClearCube Technology, Inc. Quick KVM 1.1 User s Guide ClearCube Technology, Inc. Copyright 2005, ClearCube Technology, Inc. All rights reserved. Under copyright laws, this publication may not be reproduced or transmitted in any

More information

FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version

FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version 2009.1 2009 Sage Software, Inc. All rights reserved. Published by Sage 2325 Dulles Corner

More information

Installation Guide for Windows

Installation Guide for Windows Installation Guide for Windows IDL Version 5.4 September, 2000 Edition Copyright Research Systems, Inc. All Rights Reserved Restricted Rights Notice The IDL software program and the accompanying procedures,

More information

Print It Right, Right Away

Print It Right, Right Away - Océ Windows Printer Driver 2 Print It Right, Right Away o User guide Océ WPD2 Application Copyright 2012, Océ All rights reserved. No part of this work may be reproduced, copied, adapted, or transmitted

More information

Network Management Utility

Network Management Utility 4343-7705-02 Network Management Utility Foreword Welcome Network Management Utility is utility software that provides central control over printers, copiers, and other devices on a network. With Network

More information

Galileo Print Manager Installation Guide

Galileo Print Manager Installation Guide Galileo Print Manager Installation Guide 24 November 2003 Copyright 2003 Galileo International. All rights reserved. Information in this document is subject to change without notice. The software described

More information

LPR for Windows 95/98/Me/2000 TCP/IP Printing User s Guide

LPR for Windows 95/98/Me/2000 TCP/IP Printing User s Guide LPR for Windows 95/98/Me/2000 TCP/IP Printing User s Guide Rev. 02 (August, 2001) Copyright Statement Trademarks Copyright 1997 No part of this publication may be reproduced in any form or by any means

More information

BAAN IVc. BAAN Windows Client Installation Guide

BAAN IVc. BAAN Windows Client Installation Guide BAAN IVc A publication of: Baan Development B.V. P.O.Box 143 3770 AC Barneveld The Netherlands Printed in the Netherlands Baan Development B.V. 1998. All rights reserved. The information in this document

More information

Galileo - Socrates - SNCF. Installation Guide for Windows Xp

Galileo - Socrates - SNCF. Installation Guide for Windows Xp Galileo - Socrates - SNCF Installation Guide for Windows Xp Copyright 1999 Galileo International. All rights reserved. Information in this document is subject to change without notice. The software described

More information

Symantec pcanywhere 12.5 SP4 Release Notes

Symantec pcanywhere 12.5 SP4 Release Notes Symantec pcanywhere 12.5 SP4 Release Notes Symantec pcanywhere 12.5 SP4 Release Notes The software described in this book is furnished under a license agreement and may be used only in accordance with

More information

Installing AppleWorks 6 FOR WINDOWS

Installing AppleWorks 6 FOR WINDOWS apple Installing AppleWorks 6 FOR WINDOWS 1 Installing AppleWorks 6 This booklet provides instructions for m installing and uninstalling AppleWorks m setting up an AppleWorks Installer on a server, so

More information

Installation Instructions

Installation Instructions New System Installation Instructions Last updated January 2014 Table of Contents SYSTEM REQUIREMENTS... 3 1. OVERVIEW... 4 1.1 CD ROM CONTENTS... 4 1.2 PRODUCT REGISTRATION NUMBERS... 4 Manual Product

More information

Kinetica 5.1 Kinetica Installation Guide

Kinetica 5.1 Kinetica Installation Guide Kinetica 5.1 Kinetica Installation Guide 2012 Thermo Fisher Scientific Inc. All rights reserved. The information in this document is subject to change without notice and should not be construed as a commitment

More information

RWT Network System Installation Guide

RWT Network System Installation Guide RWT Network System Installation Guide Copyright 2003, Talking Fingers, Inc. Page 1 of 48 This document is Copyright 2003 by Talking Fingers, Inc. All rights are reserved. This document may not be copied

More information

InventoryControl Quick Start Guide

InventoryControl Quick Start Guide InventoryControl Quick Start Guide Copyright 2013 Wasp Barcode Technologies 1400 10 th St. Plano, TX 75074 All Rights Reserved STATEMENTS IN THIS DOCUMENT REGARDING THIRD PARTY PRODUCTS OR SERVICES ARE

More information

FAS Asset Accounting FAS Asset Inventory FAS CIP Accounting Network Installation & Administration Guide Version

FAS Asset Accounting FAS Asset Inventory FAS CIP Accounting Network Installation & Administration Guide Version FAS Asset Accounting FAS Asset Inventory FAS CIP Accounting Network Installation & Administration Guide Version 2009.1 2009 Sage Software, Inc. All rights reserved. Portions Copyrighted 1991-2001 by ianywhere

More information

E-FORM GETTING STARTED GUIDE THE COMPLETE ELECTRONIC TAX FORM DVD

E-FORM GETTING STARTED GUIDE THE COMPLETE ELECTRONIC TAX FORM DVD E-FORM GETTING STARTED GUIDE THE COMPLETE ELECTRONIC TAX FORM DVD Updated November 2014 Copyright 2014-2015 Thomson Reuters. All Rights Reserved. Thomson Reuters disclaims any and all liability arising

More information

MF9300. Software setup guide

MF9300. Software setup guide MF900 Software setup guide 0000 79-0 S INTRODUCTION This manual explains how to install and configure the software that is required for the printer function of the machine. The procedure for viewing the

More information

Fleet Manager 2002 Professional Network Configuration Guide

Fleet Manager 2002 Professional Network Configuration Guide Handling a complex world. Fleet Manager 2002 Professional Network Configuration Guide Overview The VDO Fleet Manager Professional utilises an advanced three-tier client-server model and is designed to

More information

Laser Beam Printer. Network Guide. IMPORTANT: Read this manual carefully before using your printer. Save this manual for future reference.

Laser Beam Printer. Network Guide. IMPORTANT: Read this manual carefully before using your printer. Save this manual for future reference. Laser Beam Printer Network Guide IMPORTANT: Read this manual carefully before using your printer. Save this manual for future reference. ENG Network Guide How This Manual Is Organized Chapter 1 Before

More information

Document Centre 286/236 Series PostScript User Guide

Document Centre 286/236 Series PostScript User Guide Document Centre 286/236 Series PostScript User Guide The AppleTalk protocols and computer programs are licenced from Apple Computer, Inc. AppleTalk, EtherTalk, Apple and Macintosh are trademarks of Apple

More information

ATX Document Manager. User Guide

ATX Document Manager. User Guide ATX Document Manager User Guide ATX DOCUMENT MANAGER User Guide 2008 CCH Small Firm Services. All rights reserved. 6 Mathis Drive NW Rome, GA 30165 No part of this manuscript may be copied, photocopied,

More information

PAL Installation Instructions

PAL Installation Instructions PAL Installation Instructions ADMINISTRATOR (NETWORK) INSTALLS These instructions are for PCs that are connected by a network, for the purpose of sharing PAL data and notes. PAL can be installed using

More information

Print Audit 6. Print Audit 6 Documentation Apr :07. Version: Date:

Print Audit 6. Print Audit 6 Documentation Apr :07. Version: Date: Print Audit 6 Version: Date: 37 21-Apr-2015 23:07 Table of Contents Browse Documents:..................................................... 3 Database Documentation.................................................

More information

Single User Installation Guide

Single User Installation Guide Single User Installation Guide Copyright 1998-2005, E-Z Data, Inc. All Rights Reserved. No part of this documentation may be copied, reproduced, or translated in any form without the prior written consent

More information

SAS Installation Instructions Windows 2003, XP, 2000, NT. Workstation Installation Guidelines

SAS Installation Instructions Windows 2003, XP, 2000, NT. Workstation Installation Guidelines UCit Instructional and Research Computing, Software Distribution Office, 303B Zimmer Hall, Cincinnati, OH 45221-0088. Phone: (513) 556 9068 Email: Software@uc.edu SAS 9.1.3 Installation Instructions Windows

More information

Novell BorderManager 3.7

Novell BorderManager 3.7 Novell Novell BorderManager 3.7 3.7 QUICK START www.novell.com Installing Novell BorderManager This section provides instructions for installing the Novell BorderManager 3.7 (NBM 3.7) software. SYSTEM

More information

KG-TOWER Software Download and Installation Instructions

KG-TOWER Software Download and Installation Instructions KG-TOWER Software Download and Installation Instructions Procedures are provided for three options to download and install KG-TOWER software version 5.1. Download to a temporary folder and install immediately.

More information

Installation & Activation Guide. Lepide Exchange Recovery Manager

Installation & Activation Guide. Lepide Exchange Recovery Manager Lepide Exchange Recovery Manager Lepide Software Private Limited, All Rights Reserved This User Guide and documentation is copyright of Lepide Software Private Limited, with all rights reserved under the

More information

KODAK Dental Imaging Software Installation Guide for the KODAK1500 Intraoral Camera

KODAK Dental Imaging Software Installation Guide for the KODAK1500 Intraoral Camera 8H7854-01 KODAK Dental Imaging Software Installation Guide for the KODAK1500 Intraoral Camera Notice Carestream Health, Inc., 2009. No part of this publication may be reproduced, stored in a retrieval

More information

Network Scanner Tool V3.3. User s Guide Version

Network Scanner Tool V3.3. User s Guide Version Network Scanner Tool V3.3 User s Guide Version 3.3.09 Copyright 2000-2012 by SHARP CORPORATION. All rights reserved. Reproduction, adaptation or translation without prior written permission is prohibited,

More information

AIS Server Installation Guide

AIS Server Installation Guide AIS Server Installation Guide Table of Contents Overview of AIS Server... 1 System Requirements... 3 Installation Sequence... 4 Installing SQL Server 2005 Express Edition... 5 Configuring SQL Server 2005

More information

Media Archive Server for Small Teams

Media Archive Server for Small Teams Media Archive Server for Small Teams Installation Guide Daminion Server 0.9.X beta This 5-minute guide will help you set up and configure your Daminion Server Software correctly. Please take the time to

More information

PlexService 2.5 Installation Guide

PlexService 2.5 Installation Guide PlexService 2.5 Installation Guide Copyright 2000-2003 K-Plex Inc. All rights reserved Page 1 Table of Contents 1 Introduction... 3 2 System Requirements... 4 2.1 Hardware... 4 2.2 Software... 4 3 Installation...

More information

EventMaster PLUS! Version 4 Installation and Upgrade Guide. Workgroup Deployment Microsoft MSDE 2000

EventMaster PLUS! Version 4 Installation and Upgrade Guide. Workgroup Deployment Microsoft MSDE 2000 EventMaster PLUS! Version 4 Installation and Upgrade Guide Deployment Microsoft MSDE 2000 EventMaster4 PLUS! EventMaster4 PLUS! EventMaster4 PLUS! EventMaster4 PLUS! Please send any comments regarding

More information

MapMarker Plus Desktop Installation Guide

MapMarker Plus Desktop Installation Guide MapMarker Plus 11.0 Desktop Installation Guide Information in this document is subject to change without notice and does not represent a commitment on the part of the vendor or its representatives. No

More information

Silk Performance Manager Installation and Setup Help

Silk Performance Manager Installation and Setup Help Silk Performance Manager 18.5 Installation and Setup Help Micro Focus The Lawn 22-30 Old Bath Road Newbury, Berkshire RG14 1QN UK http://www.microfocus.com Copyright 2004-2017 Micro Focus. All rights reserved.

More information

Install Manual. P2 Software ENGLISH M0509AT5091 -FJ VQT2G26-4

Install Manual. P2 Software ENGLISH M0509AT5091 -FJ VQT2G26-4 Install Manual P2 Software M0509AT5091 -FJ ENGLISH VQT2G26-4 Contents Operating Precautions When Using Windows 1. Before Installing................................................... 3 2. Precautions in

More information

DCN Software Installation Instructions. en Software Installation Instructions

DCN Software Installation Instructions. en Software Installation Instructions DCN Software Installation Instructions en Software Installation Instructions DCN Software Installation Instructions en 3 Table of contents 1 Introduction... 4 2 Installing the DCN software... 5 3 Installation

More information

Virtual Recovery Assistant user s guide

Virtual Recovery Assistant user s guide Virtual Recovery Assistant user s guide Part number: T2558-96323 Second edition: March 2009 Copyright 2009 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company makes no warranty of any kind

More information

IPNexus Server Secure Instant Messaging & Integrated Collaboration

IPNexus Server Secure Instant Messaging & Integrated Collaboration IPNexus Server Secure Instant Messaging & Integrated Collaboration Version 1.5 Installation & Setup Guide DOC00023 Rev. 1.0 01.03 VCON IPNexus Server Installation & Setup Guide 1 2003 VCON Ltd. All Rights

More information

Password Changer User Guide

Password Changer User Guide Active@ Password Changer User Guide Copyright 1999-2017, LSOFT TECHNOLOGIES INC. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative

More information

Software Package Installation Instructions

Software Package Installation Instructions Introduction Novar provides an automatic installation package that involves reading simple, easy-to-follow instructions on each screen and clicking on the appropriate options. This document provides detailed

More information

Installing TimeMap User Guide

Installing TimeMap User Guide Installing TimeMap User Guide TimeMap, Version 6.0 System Requirements Installing TimeMap Updating TimeMap Versions TimeMap Installation Guide No part of this work may be reproduced or transmitted in any

More information

Inmagic DB/TextWorks Installation and Upgrade Notes

Inmagic DB/TextWorks Installation and Upgrade Notes Inmagic DB/TextWorks 12.00 Installation and Upgrade Notes This document is intended for new DB/TextWorks installations and sites that are upgrading to version 12.00. DB/TextWorks is a content management

More information

LifeSize Gatekeeper Installation Guide

LifeSize Gatekeeper Installation Guide LifeSize Gatekeeper Installation Guide July 2008 Copyright Notice 2008 LifeSize Communications Inc, and its licensors. All rights reserved. LifeSize Communications has made every effort to ensure that

More information

NEC PowerMate VT 300 Series Release Notes

NEC PowerMate VT 300 Series Release Notes NEC PowerMate VT 300 Series Release Notes The PowerMate VT 300 Series Release Notes provide up-to-date information on installing the applications that come with your computer. These notes also provide

More information

Quick Start Guide. Takes only a few minutes to read S. De Anza Blvd., Suite #106 San Jose, CA Phone: (408) Fax: (408)

Quick Start Guide. Takes only a few minutes to read S. De Anza Blvd., Suite #106 San Jose, CA Phone: (408) Fax: (408) Quick Start Guide Takes only a few minutes to read 1340 S. De Anza Blvd., Suite #106 San Jose, CA 95129 Phone: (408) 872-3103 Fax: (408) 861-9601 Welcome to AddressGrabber Suite! Thank you for choosing

More information

Installing TextMap. User Guide. Preliminary Planning Installing TextMap Installing TextMap Binder Import Utility. TextMap, Version 9.

Installing TextMap. User Guide. Preliminary Planning Installing TextMap Installing TextMap Binder Import Utility. TextMap, Version 9. Installing TextMap User Guide TextMap, Version 9.1 Preliminary Planning Installing TextMap Installing TextMap Binder Import Utility TextMap Installation Guide No part of this work may be reproduced or

More information

Management Server Recommendation for Entercept 4.0 looks like this:

Management Server Recommendation for Entercept 4.0 looks like this: created by: Rainer Bemsel Version 1.0 Dated: May/10/2003 The purpose of this document is to provide you with all necessary steps to install Entercept Server and Entercept Console. I ve used a 45 days evaluation

More information

License Server

License Server License Server 11.13.0.2 Installation Guide Isograph Copyright 2015 Isograph Limited. All rights reserved. This document and the associated software contains proprietary information which is protected

More information

Series 40 6th Edition SDK, Feature Pack 1 Installation Guide

Series 40 6th Edition SDK, Feature Pack 1 Installation Guide F O R U M N O K I A Series 40 6th Edition SDK, Feature Pack 1 Installation Guide Version Final; December 2nd, 2010 Contents 1 Legal Notice...3 2 Series 40 6th Edition SDK, Feature Pack 1...4 3 About Series

More information

Installing MachineShop... 2

Installing MachineShop... 2 Table of Contents Installing MachineShop.................. 2 System Requirements.................... 2 Installing the MachineShop Suite........... 4 Installing Network Communication Software.. 5 Installing

More information

VMware Workstation 4 What s New Requirements Installation Guest OS Installation Documentation Troubleshooting Prev Contents Last Next Installing VMware Tools The following sections describe how to install

More information

Magic Card Professional

Magic Card Professional Magic Card Professional User Manual Table of Contents System Requirements... 2 1. Installation... 3 2. Magic Card Settings... 5 2.1 Set Protection... 6 2.2 Set Parameters... 8 2.3 Password... 10 2.4 CMOS

More information

Manual - TeamViewer 3.5

Manual - TeamViewer 3.5 Manual - TeamViewer 3.5 Revision TV3.5-3895-g Table of Contents Table of Contents 1 Introduction... 1 1.1.1 About TeamViewer... 1 1.1.2 New in version 3.5... 1 1.1.3 About this manual... 1 2 Installation...

More information

Avid Technology, Inc. Avid LeaderPlus Version Release Notes

Avid Technology, Inc. Avid LeaderPlus Version Release Notes Avid Technology, Inc. Avid LeaderPlus Version 5.2.26 Release Notes This document supplements the Avid LeaderPlus Operations Manual available in PDF and is included on the installation CD as well as the

More information

Installation and Administration Guide

Installation and Administration Guide SWIFTNet Interfaces SWIFTAlliance Workstation 6.0 Installation and Administration Guide This guide is intended for the person responsible for installing and administering SWIFTAlliance Workstation. Prior

More information

Topcat. Installation Guide. Version 1.03

Topcat. Installation Guide. Version 1.03 Microlynx Software Engineering Topcat Installation Guide Version 1.03 1998 Microlynx Software Engineering ii Copyright 1998 Microlynx Software Engineering Neither the whole nor any part of the information

More information

Admin Guide. LabelShop 8

Admin Guide. LabelShop 8 Admin Guide LabelShop 8 Administrator s guide DOC-OEMCS80-AG-US-02/03/06 The information in this manual is not binding and may be modified without prior notice. Supply of the software described in this

More information

SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM

SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM SOFTWARE SETUP GUIDE DIGITAL MULTIFUNCTIONAL SYSTEM BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING AND USEFUL INFORMATION Page 2 8 29 36

More information

MapMarker for Windows Installation Guide

MapMarker for Windows Installation Guide MapMarker for Windows 10.0 Installation Guide Information in this document is subject to change without notice and does not represent a commitment on the part of the vendor or its representatives. No part

More information

Roland CutChoice. Ver. 1 USER S MANUAL

Roland CutChoice. Ver. 1 USER S MANUAL Roland CutChoice Ver. 1 USER S MANUAL Thank you very much for purchasing the Roland cutter. To ensure correct and safe usage with a full understanding of this product s performance, please be sure to read

More information

Virtual CD TS 1 Introduction... 3

Virtual CD TS 1 Introduction... 3 Table of Contents Table of Contents Virtual CD TS 1 Introduction... 3 Document Conventions...... 4 What Virtual CD TS Can Do for You...... 5 New Features in Version 10...... 6 Virtual CD TS Licensing......

More information

User Guide Communication 2000: Communication and Ethics CD Study Guide

User Guide Communication 2000: Communication and Ethics CD Study Guide User Guide CD Study Guide focuses on the skills you need for communicating and acting ethically in the workplace. Explore how to understand the consequences of your decisions, be accountable for your actions,

More information

Inmagic DB/TextWorks 9.00 Installation and Upgrade Notes

Inmagic DB/TextWorks 9.00 Installation and Upgrade Notes Inmagic DB/TextWorks 9.00 Installation and Upgrade Notes Thank you for purchasing Inmagic DB/TextWorks. This document is for new DB/TextWorks installations and sites that are upgrading to version 9.00.

More information

Inmagic DB/TextWorks Installation and Upgrade Notes

Inmagic DB/TextWorks Installation and Upgrade Notes Inmagic DB/TextWorks 10.00 Installation and Upgrade Notes This document is intended for new DB/TextWorks installations and sites that are upgrading to version 10.00. DB/TextWorks is a content management

More information

pcaframe Quick Start Guide

pcaframe Quick Start Guide System Requirements pcaframe Quick Start Guide Operating systems Microsoft Windows 95 Windows 98 Second Edition Windows ME Windows NT4 Windows 2000 Windows XP Minimum Requirements 100 MHz processor 32

More information

EventMaster PLUS! Version 4 Installation and Upgrade Guide. Enterprise Deployment Microsoft SQL Server

EventMaster PLUS! Version 4 Installation and Upgrade Guide. Enterprise Deployment Microsoft SQL Server EventMaster PLUS! Version 4 Installation and Upgrade Guide Deployment Microsoft SQL Server EventMaster4 PLUS! EventMaster4 PLUS! EventMaster4 PLUS! EventMaster4 PLUS! Please send any comments regarding

More information

LASER PRINTER. Software Setup Guide BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING

LASER PRINTER. Software Setup Guide BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING MODEL: MX-B400P LASER PRINTER Software Setup Guide BEFORE INSTALLING THE SOFTWARE SETUP IN A WINDOWS ENVIRONMENT SETUP IN A MACINTOSH ENVIRONMENT TROUBLESHOOTING Keep this manual close at hand for reference

More information

Novell ZENworks Asset Management 7.5

Novell ZENworks Asset Management 7.5 Novell ZENworks Asset Management 7.5 w w w. n o v e l l. c o m October 2006 MIGRATING & UPGRADING Table Of Contents 1. Migrating and Upgrading... 3 Upgrading from Earlier Versions...3 Upgrading Client

More information

Isograph Software Products

Isograph Software Products Isograph Software Products Installation and Licensing Guide Isograph Copyright 2018 Isograph Limited. All rights reserved. This document and the associated software contains proprietary information which

More information