1. Before you can use your addresser you will need to install the ULinx RS485 USB Adapter.
|
|
- Berniece Wilkerson
- 5 years ago
- Views:
Transcription
1 1. Before you can use your addresser you will need to install the ULinx RS485 USB Adapter. A. B. 2. Addresser Software Instructions and Screenshots PRO-PRM Website Addresser 3_14 Pg 1 of 22
2 A. If you have not yet installed the VI TERMINAL that was on your CD, please stop here and install the VI TERMINAL FIRST. It contains a National Instruments Run Time Engine that is required to properly install the Addresser program. B. Install the Addresser Software onto your computer. 1) Right click on the ADDRESSER INSTALLER 3.14, and select Extract all. 2) 3) 4) You might select your Desktop as a destination for the extracted files. 5) PRO-PRM Website Addresser 3_14 Pg 2 of 22
3 6) Click Finish 7) When extraction is complete, locate the folder on your Desktop labeled Addresser Installer 3_14, and open it. 8) 9) Open the setup Application. 10) 11) Double click or Open the setup application PRO-PRM Website Addresser 3_14 Pg 3 of 22
4 12) 13) 1. Note where the Addresser program will be installed, C:\Program Files\Addresser\, and then click Next 2., click Next PRO-PRM Website Addresser 3_14 Pg 4 of 22
5 3., then finally, 4., click Finish. 3. Once the Addresser application and the ULinx USB to Serial Converter have been installed you will need to determine which port on your computer is the RS485 port. A. Right click on the My Computer Icon on your desktop and select Manage. B. C. Select Device Manager, then ports (COM & LPT) PRO-PRM Website Addresser 3_14 Pg 5 of 22
6 D. There should be a port that is labeled RS-485 Isolated Port (Com _). This is the port that you will select when you start up the Addresser application. E. F. Open the Addresser G. 1) Now click on the arrow at the top left of the Addresser 2) If this is the first time you are using the addresser and the Com Port has not been assigned, you will see the following when you start Addresser. PRO-PRM Website Addresser 3_14 Pg 6 of 22
7 3) 4) Select the port as determined in step 2D and press select 5) When you select the proper port you will see a screen like this: 6) 7) If you are connecting to the meter properly, the green bar will continue across. If you are not connecting properly, the bar stays short and an error message appears. 8) If you are not connecting properly the green bar does not continue and the Addresser Error message shows up. PRO-PRM Website Addresser 3_14 Pg 7 of 22
8 9) 10) If you click on the New Port symbol, you can verify what port the Addresser is trying to talk. 11) 12) Once the appropriate com port has been selected, the Addresser will come up with another screen to Find Address or Stop. 13) PRO-PRM Website Addresser 3_14 Pg 8 of 22
9 14) If you aren t sure what the Slave or Mod Bus ID of the meter under test is, selecting the Find Address button will instruct Addresser to scan through all possible addresses/ids until it finds the right one. 15) 16) When the correct address is scanned, the Addresser green bar will indicate it is initializing communication. 17) 18) If you decided to select Stop instead of Find Address in step 2G12, the Addresser will deactivate. The arrow in the upper left corner of the Addresser will be white. 19) Just click on the white arrow to restart the Addresser PRO-PRM Website Addresser 3_14 Pg 9 of 22
10 20) 4. The first step that should be taken with a meter that is going to have some changes made is to save the existing settings to a file so that you can get back to this starting point if necessary. On the Addresser display are 4 tabs, Meter, System, Outputs, and File. 1) Select the File tab. 2) 3) Now click on Save2File. 4) 5) You will be asked to enter a file name and location to save a.dat file. PRO-PRM Website Addresser 3_14 Pg 10 of 22
11 6) 7) Enter an appropriate file name (meter SN SMB.dat). If needed at a later time, you will be able to reload this data into the flow meter. 8) You might also want to print a copy of the settings in the meter. Click on Print Report and then select where to print the file. 9) 10) This is a sample printout PRO-PRM Website Addresser 3_14 Pg 11 of 22
12 11) B. The first time that you click on Write Reg to change a setting you will get a screen that says User Passcode Required. 1) 2) This is a Passcode for Factory Only changes. Pressing Accept or Bypass will allow you to make changes to the unrestricted registers. Restricted registers will be read only. PRO-PRM Website Addresser 3_14 Pg 12 of 22
13 C. Go back to the Meter Tab, and then click on the window beneath Register Select to get a scroll listing of available registers. D. E. The K-Factor register is a useful register when changing pipe size for the flow application. Default K-Factor is ) If the factory calibration was set up for a 4 Sch 40 but you now want the meter to be placed in a 6 Sch 40, you need to set the K-Factor to the ratio of the pipe areas. Since you are placing the meter in a larger pipe, the mass flow for the same sensor mw reading will be greater. 2) Divide the 6 area by the 4 area, / = Assuming the K-Factor is now , will be the new K- Factor value. 3) Select the K-Factor register by clicking the window below Register Select, then selecting K-Factor 4) Then note the value in the window below IEEE Data this is the existing K-Factor PRO-PRM Website Addresser 3_14 Pg 13 of 22
14 5) 6) To change the K-Factor the box beneath IEEE must be checked as seen in Para ) Highlight the number in the IEEE Data box to enter a new K-Factor. 8) F. Cal Val, Lead Gain, Load Res, Temp Disp Null, Temp Disp Gain, Amp Null, and Amp Gain should generally be left alone as they were set by the factory. G. Temp[A], [B], [C], & [D] are curve coefficients for the temperature calibration. These may be checked to verify they are at the factory settings, but should not be changed in the field. H. Register flow [A] flow [F] are flow coefficients. These may be checked to verify they are at the factory settings, but should not be changed in the field. I. Register Filtering deals with the meter s response time and varies between (slowest) & (fastest). 0.5 is the typical factory setting PRO-PRM Website Addresser 3_14 Pg 14 of 22
15 J. Min Flow/LFC default is This is the minimum flow setting, i.e. 0 SCFM. If a low flow cutoff is desired, it may be entered here. Note that the 4-20 ma output will remain at 4.00 ma until the actual flow has exceeded this cutoff setting. The current output will then jump to the value determined by ((flow reading/full scale)*16) +4. K. Full Scale is the value of full scale in the Engineering Units of the meter, i.e SCFM. This corresponds to 20 ma output. This value may be changed, but the accuracy specification will still be based upon the original full scale. The coefficients flow [A] [F] remain the same. L. Min Temp is default 40. M. Units per Pulse refers to the Pulse Count, i.e. 1 pulse for every 100 SCF. N. The remainder of the registers in the scroll menu of Register Select should be left alone. O. Select the System tab in the lower section of the Addresser Plus display. 1) To change engineering units, enter the desired units in the Units Text box, 4 digits for rate and 3 for total. Caution, changing these engineering units will require a change to the K-Factor and full scale. 2) PRO-PRM Website Addresser 3_14 Pg 15 of 22
16 3) 4) When changing engineering units, changes to hours, minutes, or seconds will not take affect with the totalizer function until the meter power is cycled off then on, or the meter is reset. 5) The K-factor changes are: 1. SCFM to SCFH -> K-Factor = SCFM to SCFS -> K-Factor = 1/60 = ) The full scale may need to be changed as well. You may increase it by 60 times if going from SCFM to SCFH, or decrease it to 1/60 if from SCFM to SCFS. 7) Prime will only measure in terms of seconds, minutes, or hours. It will not operate in engineering terms of Days. The 4 th character of the rate must be S, M, or H. Do not use lower case. 8) PRO-PRM Website Addresser 3_14 Pg 16 of 22
17 9) You can also change from Deg F to Deg C. Click in the appropriate circle. 10) Optional Baud rate of 9600, and parity ODD or NONE may also be selected. Caution, changing from the default settings will affect how you can communicate through the SMB Server to the meter under test. If these settings are changed, and the communication link is broken, you cannot just restart the SMB Server as in the beginning. 11) If baud rate or parity has been changed, the meter must be powered down, then back on again. During this power up sequence, you must activate communication with the meter by clicking on the arrow symbol at the upper left portion of the Addresser display 12) 13) You can also change the Slave ID, click on SetSlaveID 14) 15) Enter the new address in Hex, and then click OK. PRO-PRM Website Addresser 3_14 Pg 17 of 22
18 16) Note that the Device Address in the upper left corner of the Addresser is in Decimal in the default mode. This can be changed to hex. Click the dark gray box to the left of the address block, and then select how you want the Device Address shown. 17) 18) You may also set the number of decimals to be displayed on the meter display, from 0 to 3 decimals. In the System tab, Click Set Disp Decimal. 19) 20) Move the slider to the left until the desired decimal is shown, then click OK. 21) Note that this same Set Disp Decimal box also has a Screen Saver listed. 1. A check in the ScreenSaver box turns screensaver mode on 2. No check signifies ScreenSaver is off PRO-PRM Website Addresser 3_14 Pg 18 of 22
19 3. 22) The Factory Serial# cannot be changed. P. Select the Outputs tab in the lower section of the Addresser display. This controls the output settings 1. No DAC gives you no 4-20 or pulsed output. 2. Flow Out gives only 4-20 output for flow 3. Temp Out gives only 4-20 output for temp 4. Pulse Out gives both flow 4-20 and Pulsed output. 5. Pulse width can be adjusted from 10 msec to 1,000 msec a. 6. The 4-20 output, whether for flow or temp, is set by adjusting the sliders or the numbers in the boxes next to Min and Max PRO-PRM Website Addresser 3_14 Pg 19 of 22
20 a. b. c. Click the Command Bit SET OUT LOW, and then adjust the ma output to 4.00 ma as measured between pins C5 & C6 of the user accessible terminals. d. e. Click the SET OUT LOW Command Bit again to turn it off, then click on SET OUT HIGH, and then adjust the ma output to ma as measured at pins C5 & C6 7. If Pulse Out is selected, the flow 4-20 and pulsed output are both activated. The number of mass flow units per pulse is set with the Units per Pulse Register previously described. PRO-PRM Website Addresser 3_14 Pg 20 of 22
21 8. Q. If your meter is equipped with Screen Saver code, 1.88 and newer, you may optionally turn off the screen saver though this is not recommended. The Screen Saver is standard on the Prime to extend the life of the OLED display. Turning it off will likely cause premature failure of the display. R. To restore a saved.dat file such as in step 3 go to the file tab of the Addresser. 1) PRO-PRM Website Addresser 3_14 Pg 21 of 22
22 2) 3) Click on LoadFile, and select the.dat file you wish to restore: 4) When you click OK the Addresser will be loaded with the registers stored in the.dat file selected. 5) A reminder to Save2Meter will come up on the display 6) Click OK, and then click on Save2Meter 7) This will transfer the data from the Addresser to the meter. PRO-PRM Website Addresser 3_14 Pg 22 of 22
FT2 View Instruction Manual
399 Reservation Road, Marina, California U.S.A. Ph: (831) 384-4300 Fax: (831) 337-5786 www.foxthermalinstruments.com 2006 Fox Thermal Instruments, Inc. 07/19/13 Introduction: The FT2 View application software
More informationSage Service Manual-Rev Remote Wiring Issues Page Common Diagnostics Page Installing / using Addresser Page 8
1.0 Remote Wiring Issues Page 2 2.0 Common Diagnostics Page 4 3.0 Installing / using Addresser Page 8 3.1 SAGE ADDRESSER TECHNICAL ASSISTANCE Page 8 3.2 Sage Addresser Common Installation Difficulties
More informationCyberComm Pro Data Acquisition Software Installation & User Guide
CyberComm Pro 2.2.3 Data Acquisition Software Installation & User Guide ph 1100 and ph 2100 Bench ph and Bench ph/ion Meter Technology Made Easy... 68X090822 rev 1 Aug 2002 2 PREFACE Thank you for selecting
More informationInstructions for Installing FlashUpdate and Downloading Updates for NPRT 2200 Noise Power Ratio Test Set
Instructions for Installing FlashUpdate and Downloading Updates for NPRT 2200 Noise Power Ratio Test Set Updates to the instrument firmware are available from the Applied Instruments website. Requirements
More informationSeries Instruments System10
UtiliPac410 4500 4000 Series Instruments System10 UtiliPac410 Introduction The software package UtiliPac410 is a utility package that is sent out with every system it also can be downloaded from the web
More informationInstructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter
Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter Updates to the Field Guide and to the instrument firmware are available from the Applied Instruments website.
More informationGSC400 Series. GSC400 Programmer and PC Interface User Manual
GSC400 Series GSC400 Programmer and PC Interface User Manual GSC400 Programmer and PC Interface User Manual Full Version File: GSC400 PC Interface Rev1.2.doc, August 2009 2 of 33 Amendments Issue Section
More informationFox Thermal Instruments, Inc.
Fox Thermal Instruments, Inc. THERMAL MASS FLOW METER & TEMPERATURE TRANSMITTER FT2A View www.foxthermalinstruments.com 399 Reservation Road Marina, CA. 93933 105406 Rev. A Notice FOX THERMAL INSTRUMENTS
More informationTech Memo # Software Engineering. Normal PRIORITY: DATE: April 17 th, 2015
Software Engineering Tech Memo #15-0001 PRIORITY: Normal DATE: April 17 th, 2015 TITLE: PRODUCTS AFFECTED: TOOLS REQUIRED: NOTE: INTRODUCTION: How to install and configure Adaptive Sign Server on a Windows
More informationFT2 View Instruction Manual
399 Reservation Road, Marina, California U.S.A Ph: (831) 384-4300 Fax: (831) 384-4312 www.foxthermalinstruments.com 2006 Fox Themal Instruments, Inc. Introduction: The FT2 View application software is
More information1 How do I download my PrimeTest 350 to PATGuard 2?... 2 How do I upload my PrimeTest 350 from. 4 How do I upload a logo to my tester for printing?...
Table of Contents Page 1 How do I download my PrimeTest 350 to PATGuard 2?... 2 How do I upload my PrimeTest 350 from PATGuard 2?... 3 How to update the PrimeTest 350 Firmware.... 4 How do I upload a logo
More informationRST INSTRUMENTS LTD.
RST INSTRUMENTS LTD. VW0420 Analog VW Interface Instruction Manual Ltd. 11545 Kingston St Maple Ridge, BC Canada V2X 0Z5 Tel: (604) 540-1100 Fax: (604) 540-1005 Email: Info@rstinstruments.com i VW0420
More informationCyberComm Pro 2.4 Data Acquisition Software Installation & User Guide. CyberScan DO 1500
CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide CyberScan DO 1500 Bench Dissolved Oxygen Meter Technology Made Easy... 68X292341 Rev.0 01/04 PREFACE Thank you for selecting the CyberScan
More informationDot Matrix Indicator Programming
Dot Matrix Indicator Programming Preparation: USB Dongle and USB cable. Part No. 100-159 (see page 3 Dongle Installation Instruction ). Display Programmer V2.0 (see page 10 Display Programmer V2 Installation
More informationFlex Series User Guide
User Programmable Current 4..20mA Digital RS485 Dual & Single Axis Up to 360º 2016 Flex Series User Guide Sensor Installation, Wiring, Flexware App Instructions Page 1 of 33 Page 2 of 33 Table of Contents
More informationMotionView Configuration and Programming Software USER S MANUAL
MotionView Configuration and Programming Software USER S MANUAL IM94MV01C Table of Contents 1 MotionView Software Overview......................................... 3 1.1 Installation and Package Revision.................................................
More informationOptimizer Collect User Manual. for MFC/MFM calibration with Integrator 110 and Drycal
Optimizer Collect User Manual for MFC/MFM calibration with Integrator 110 and Drycal Table of Contents Overview of Optimizer Collect...2 PC Requirements...2 Equipment Required...2 Installing Collect on
More informationAdvanced Electronic Signs
Owner s Manual SunNet Pro SunRise LED Inc. Advanced Electronic Signs www.sunriseled.us SunRiseLED Inc. Table of Contents Software Setup... 3 ConnectionusingUSBSerial Cable... 5 ConnectionusingBluetooth...
More informationActon Research Corporation SpectraPro Monochromator Control Software for Windows
530 Main Street, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Acton Research Corporation SpectraPro Monochromator Control Software for Windows Ver 2.0 2 Contents
More informationALDL Bluetooth Adapter with USB (MK2)
1320 Electronics LLC for: ALDL Bluetooth Adapter with USB (MK2) Contents Warnings 3 Specifications 4 Quick Start Instructions 5 Installing the 'ALDL Bluetooth adapter' 6 Operating the ALDL Bluetooth Adapter
More informationFox Thermal Instruments, Inc.
Fox Thermal Instruments, Inc. THERMAL MASS FLOW METER & TEMPERATURE TRANSMITTER FT3 View www.foxthermalinstruments.com 399 Reservation Road Marina, CA. 93933 104845 Rev. D Notice FOX THERMAL INSTRUMENTS
More informationScanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A
NUFLO Part No. 30165024, Rev. A Scanner 2000 microefm QuickStart Installing the Scanner 2000 H L H L Flow Direct Mount To install the Scanner 2000 microefm using a direct mount to an orifice or cone meter
More informationD-ILA Home Theater Projector "Projector Calibration Software"
D-ILA Home Theater Projector "Projector Calibration Software" INSTRUCTIONS About "Projector Calibration Software" "Projector Calibration Software" is a tool that enables the projector to be used in an
More informationQuick Start Guide MC-III TM Flow Analyzer
Quick Start Guide MC-III TM Flow Analyzer A Quick Reference on Mounting, Wiring, & Configuring the MC-III EXP or WP Flow Analyzer For complete instructions, see MC-III EXP User Manual, Part No. 9A-50165003
More informationKTA-250 Anemometer Alarm Card
Connects to Davis Instruments DS7911 Anemometer Monitor both the wind speed and direction Interface to PLCs using the Modbus protocol Communicate via RS232 or 2-wire RS485 Interface to PLCs/Instruments
More informationTemperature-Humidity Sensor Configuration Tool Rev. A 1/25/
Rev. A 1/25/213 172 Contents Contents Temperature-Humidity Sensor Configuration Tool... 3 Read Sensor Screen... 3 Manual Calibration Screen... 4 Register View Screen... 5 Modbus Registers... 6 Reprogram
More informationCal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester. Users Guide. Rev 3.1
Cal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester Users Guide Rev 3.1 Contents... 1 Quick Start Guide... 2 Selecting a Test Specification... 3 Clearing Traces... 4 Saving Traces...4 Loading
More informationIntegral Electronics with Local Menu System
Integral Electronics with Local Menu System THERMAL INSTRUMENT COMPANY Trevose, PA 215-355-8400 New Menu Features & Benefits Available with either Hart Communication or Modbus output Visibility to current
More informationRoastLogger Arduino/TC4 driver installation for Windows 9/10/13 By John Hannon (JackH) at Homeroasters.org
This procedure was written for the Arduino Uno board with the TC4 shield. Please check the Arduino site for software if you are using a different model. I have not tested it, but this procedure should
More informationTempLog & RH/TempLog User Guide. Sixth Edition First print Printed in July
TempLog & RH/TempLog User Guide Sixth Edition First print Printed in July 2003 www.4oakton.com Contents Using the Guide... 15 Chapter 1 OaktonLog... 17 1.1. Overview... 18 1.2. Getting Started... 19 1.3.
More informationUSB SERIAL ADAPTOR COM PORT INSTRUCTIONS
USB SERIAL ADAPTOR COM PORT INSTRUCTIONS No part of this work covered by the copyright hereon may be reproduced, copied, transferred or distributed in any form or by any means -- graphic, electronic, or
More informationSetting up the PC ready for BESA 11
Setting up the PC ready for BESA 11 1 - Installing Driver. Important Note: Before you start to install the driver, please do not plug BESA 11 into the computer s USB port or else the installation will
More informationSerial Adaptor Isolated USB to TTL Device Driver - Installation Guide 1 Introduction. 2 Installing the Device Driver Software (Windows XP )
Serial Adaptor Isolated USB to TTL Device Driver - Installation Guide 1 Introduction This installation guide describes a simple, step-by-step procedure to enable the supplied Serial Adapter to work using
More informationSeries 8L Alarm Aux Setpoint Configuration
Series 8L Alarm Aux Setpoint Configuration Procedure 1. Connect the Series 8L communication terminals to the Slave 1 RS485 terminals on the 9XXX controller. a. The Series 8L controller terminals for communication
More informationOperating the meter 13. j h g. 4.1 Backside layout Pin assignments RS232 connection
4 Operating the meter 4.1 Backside layout c d e f a b j h g a b c d e f g h i BNC socket for mv/ph signal input RCA (Cinch) socket for temperature signal input Reference socket for reference electrodes
More informationVSM Manager. The VSM Manager is a Windows GUI that can be installed to serially control Genesis Matrixes with a firmware of version 2.5 or later.
VSM Manager Table of Contents Overview...1 Getting Started...1 Toolbar... 2 Serial Connection... 2 Refresh... 3 Help... 3 Tab Pages... 4 General... 4 Control...5 Schedule... 6 Command... 6 Communications...
More informationOPERATING MANUAL AND TECHNICAL REFERENCE
MODEL WFG-D-130 HIGH SPEED DIGITAL 3 AXIS FLUXGATE MAGNETOMETER OPERATING MANUAL AND TECHNICAL REFERENCE December, 2012 Table of Contents I. Description of the System 1 II. System Specifications.. 2 III.
More informationGSC400 Series. GSC400 Programmer and PC Interface User Manual
GSC400 Series GSC400 Programmer and PC Interface User Manual GSC400 Programmer and PC Interface User Manual Full Version File: GSC400 PC Interface Rev1.5.doc, December 2010 2 of 42 Thank You For Purchasing
More informationSCA8X0-21X Demo Kit User Manual. Doc.Nr C
SCA8X0-21X0-3100 Demo Kit TABLE OF CONTENTS SCA8X0-21X0-31X0 DEMO KIT 1 Introduction...3 2 Quick start for using the SCA8X0-21X0-31X0 DEMO KIT...3 3 Hardware...4 4 GUI software...4 4.1 Resetting GUI and
More informationSHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions
SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions http://www.kep.com KESSLER-ELLIS PRODUCTS 10 Industrial Way East Eatontown, NJ 07724 800-631-2165 732-935-1320
More informationD8000 SERIES QUICK START GUIDE
D8000 SERIES QUICK START GUIDE Version 1.0 Overview The D8000 series modules require a DC Voltage power supply, a USB cable and an unused computer USB port for proper operation. Connecting the D8000 series
More informationPen Drive USB Datalogger!
SINGLE PHASE POWER METER Isolated V/I converter -RS485 Modbus - Datalogger Single-phase power meter RMS, and Voltage/Current Isolated. Signal Converter 1000 VDC / 600 VAC, 10 A AC/DC, Variable frequency
More informationD-ILA Projector JVC Projector Calibration Software 10 INSTRUCTIONS
D-ILA Projector JVC Projector Calibration Software 10 About the marks being used in this manual INSTRUCTIONS X990R refers to as explanations/instructions for DLA-X990R series. X590R refers to as explanations/instructions
More informationMicrosystems. UVK-200/UCW-100 Programmer s Manual. Rev April 29, Overview
UM Unified Microsystems UVK-200/UCW-100 Programmer s Manual Rev. 1.01 April 29, 2005 Overview Newer PCs, especially lap tops often do not have COM or LPT ports which are frequently used to interface PCs
More informationFAC-R Frequency to Analog Converter Installation, Operating & Maintenance Manual
COMPANY FAC-R Frequency to Analog Converter Installation, Operating & Maintenance Manual 2017 AW-Lake Company. All rights reserved. Doc ID:FACMAN12082017 V4 Table of Contents Product Overview...3 Operation...3
More informationNPRT 2200 Operation Manual
NPRT 2200 Operation Manual Module Version NPRT 2200 4.05 NprGraph 2.11 SwpEditor 2.00 12/02/2016 Table of Contents 1. Introduction...1 1.1. NPR Measurement...1 1.2. NPRT Block Diagram...1 1.3. Power Sweep
More informationSmartLink Configuration Manual
SmartLink Configuration Manual October 2012 Part No. 4417554 Revision 2 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com Website
More informationNavigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17
User Manual Navigator Software Monarch Instrument Rev 0.98 May 2006 Page 1 of 17 Contents 1. NAVIGATOR SOFTWARE 2. INSTALLATION 3. USING NAVIGATOR SOFTWARE 3.1 STARTING THE PROGRAM 3.2 SYSTEM SET UP 3.3
More informationSCI Testers and Remote Communication: Using HyperTerminal
Testers and Remote Communication: Using HyperTerminal Introduction Programmable industrial equipment has long been a staple for automation in manufacturing environments. The capability to remotely program
More informationUSB SERIAL ADAPTOR COM PORT INSTRUCTIONS
USB SERIAL ADAPTOR COM PORT INSTRUCTIONS No part of this work covered by the copyright hereon may be reproduced, copied, transferred or distributed in any form or by any means -- graphic, electronic, or
More informationEV Evaluation System User Guide. Contents. Kit Contents. Introduction
Contents EV2200 40 Evaluation System User Guide Section Page No. Introduction 1 Kit Contents 1 Hardware and Software Setup 2 Software Installation 2 Hardware Connection 2 Operation 2 Starting the Program
More informationThe Art of Measuring. User Manual English. Paraly SW 112. Latest Product Information:
The Art of Measuring. User Manual English Paraly SW 112 Latest Product Information: www.knick.de Basics 3 Registered trademarks The following names are registered trademarks. For practical reasons they
More informationGraphical User Interface V1.0.3
Graphical User Interface V1.0.3 Application User Guide 2015 MCI Solutions. All rights reserved. 240815-01 www.mcisolutions.ca Page ii Getting Started Table Of Contents Introduction.................................................
More informationDSTCAL Software User Manual 09/16/09 WD1037 Rev E Revised 09/09/14
DSTCAL Software User Manual 09/16/09 WD1037 Rev E Revised 09/09/14 Wahl Instruments, Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free 800-421-2853 Phone 828-658-3131 Fax 828-658-0728 www.palmerwahl.com
More informationInstalling the Tibbo Device Server Toolkit
Ethernet Time Clock Tibbo Software Installation and Configuration V5.7 for Windows Vista and Windows 7 When using the Icon Time Systems PROX or PIN Entry Employee Time Clocks with Ethernet capabilities,
More informationFutek Advanced Sensor Technology- Futek IPM500/IBT500 Software Documentation Rev April 27, 2006
DISPLAY TAB FUNCTIONS Tracking Mode (Blue)- Continuous readings from the display are shown on the screen. Peak Mode (Yellow)- This function allows a peak (high) reading to be displayed on the screen. The
More informationUVK-200/UCW-100 Programmer s Manual
UVK-200/UCW-100 Programmer s Manual Rev. 1.02 June, 2005 Overview Newer PCs, especially lap tops often do not have COM or LPT ports which are frequently used to interface PCs to Ham Radio equipment. This
More informationUSB-Link Technical Guide
www.wattmaster.com USB-Link Technical Guide USB-Link Code: SS0070 Table of Contents General Information... 3 USB-Link Overview...3 System Requirements...3 Quick Guide... 4 Connection and Wiring... 5 USB-Link
More informationData Acquisition Software and Hardware Demonstration Guide
Data Acquisition Software and Hardware Demonstration Guide For: NetDAQ Logger for Windows Hydra Logger for Windows Trend Link for Fluke Introduction This demonstration guide contains exercises designed
More informationMercury itc and ips Application and Firmware updates via USB
Mercury itc and ips Application and Firmware updates via USB This document presents guidelines to application (software) and device (card) firmware updates for Mercury systems. To distinguish between these
More informationFTI 3000 Manual Lookout Road, Boulder, CO Phone: Fax:
FTI 3000 Manual 6655 Lookout Road, Boulder, CO 80301 Phone: 303-442-1650 Fax: 303-530-1147 www.focusedtest.com Specifications... 3 Configuration Parameters and Test Conditions... 4 Diode String Configuration
More informationPV101-C Configuration Software V3.2. Installation and Operations Manual Section 78
PV101-C Configuration Software V3.2 Installation and Operations Manual 00-02-0797 08-18-11 Section 78 In order to consistently bring you the highest quality, full featured products, we reserve the right
More informationGosHawk II COMMUNICATIONS
Version 4..10 GosHawk II COMMUNICATIONS Operating Instructions Introduction This program is a set-up and diagnostic utility for the Hawk SULTAN range of ultrasonic units. Hawk SULTAN units are designed
More informationUser Manual. Thermo Scientific Orion
User Manual Thermo Scientific Orion Orion Star Com Software Program 68X637901 Revision A April 2013 Contents Chapter 1... 4 Introduction... 4 Star Com Functions... 5 Chapter 2... 6 Software Installation
More information9120 Redundant Probe System (RPSC)
9120 Redundant Probe System (RPSC) USER S MANUAL Super Systems Inc. 7205 Edington Drive Cincinnati, OH 45249 Ph : 513-772-0060, 800-666-4330 Fax: 513-772-9466 www.supersystems.com Super Systems Inc. help
More informationPROGRAMMING INSTRUCTIONS
HOERBIGER Engine Solutions PROGRAMMING INSTRUCTIONS CPU-XL VARISPARK TERMINAL PROGRAM WARNING: WARNING: DEVIATION DEVIATION FROM THESE FROM INSTRUCTIONS THESE INSTRUCTIONS MAY LEAD MAY LEAD TO IMPROPER
More informationMaster-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 3.1)
Master-Touch and ValuMass Modbus Communications Master-Touch and ValuMass flowmeters are shipped with the RS232 communications protocol as the factory default. Prior to connecting a flowmeter to a RS485
More informationInstruction Manual July sitrans RD SOFTWARE
Instruction Manual July 2007 sitrans RD SOFTWARE Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment.
More informationMODBUS Message Protocol MODEL FT3
MODBUS Message Protocol FOR MODEL FT3 THERMAL MASS FLOWMETER & TEMPERATURE TRANSMITTER Fox Thermal Instruments, Inc. 399 Reservation Road Marina, CA 93933 (831) 384-4300 Fax: (831) 337-5786 104985, Revision
More informationMISUMI SUPPORT SOFTWARE. RS-Manager. User s Manual C1 / C21 / C22 / P1 EXWM KE114. Ver. 2.00
MISUMI SUPPORT SOFTWARE RS-Manager User s Manual C1 / C21 / C22 / P1 Ver. 2.00 EXWM14200 KE114 CONTENTS RS-Manager User s Manual Before getting started 1 1. About RS-Manager 2 2. Installing and uninstalling
More informationTalk Light Time Manager User Instructions
Talk Light Time Manager User Instructions Talk Light Time Manager Installation and User Instructions Technical Requirements: Windows 95, Windows 98, NT, ME, Windows 2000 or XP. Hard drive space for the
More informationExpert Software Manual for Tritex II AC & DC Actuators and EXP-24 Controllers
Expert Software Manual for Tritex II AC & DC Actuators and EXP-24 Controllers Information furnished by Exlar Corporation is believed to be accurate and reliable. However, no responsibility is assumed by
More informationField PC 2 Windows OS Update Guide
Field PC 2 Windows OS Update Guide All efforts have been made to ensure the accuracy and completeness of the information contained in this document. RST Instruments Ltd reserves the right to change the
More information1 System Requirements
START User s Guide (Use with START version 2.9.1 or higher) Click to: Review the START Main Menu Download Software View Operator History Logs Enter Operator Menu Settings Perform Operator Diagnostics 1
More informationAKELA Vector Network Analyzer (VNA) Quick Start Guide
AKELA Vector Network Analyzer (VNA) Quick Start Guide Copyright AKELA, Inc. 2012, all rights reserved http:\\akelainc.com LabVIEW and LabWindows are registered trademarks of National Instruments Incorporated
More informationM2500 Engine Controller Configuration Manual
M2500 Engine Controller Configuration Manual Revision: 08-04-2011 Page 1 Contents 1 Preface... 4 2 Configuration from front panel... 5 2.1 Engine Controller Configuration... 6 2.1.1 RPM settings... 6 2.1.2
More informationGC-10 Wireless Control Box. User Guide
Wireless Control Box User Guide 1. Introduction This Installation and User Guide will assist you in installing and configuring the Brodersen SMS Alarm Unit. The guide covers the installation of the configuration
More informationBIOC3 V1 USER S MANUAL. Biometric Reader v. b1
BIOC3 V1 EN Biometric Reader USER S MANUAL v. b1 www.xprgroup.com 1 Contents 1. DESCRIPTION 2. SPECIFICATIONS 3. MOUNTING 4. WIRING 5. CONNECTING BIOMETRIC READERS TO EWS CONTROLLER 5.1 CONNECTING BIOMETRIC
More informationThermal Transient Test Installation and Operating Manual
Thermal Transient Test Installation and Operating Manual 2705A De La Vina Street Santa Barbara, California 93105 Telephone (805) 682-0900 descon@silcom.com www. santabarbaraautomation.com Installation
More information7561-PSD Manual Portable Battery Powered Indicator
7561-PSD Manual Portable Battery Powered Indicator Lebow Products Inc. 1728 Maplelawn Drive P.O. Box 1089 Troy, Michigan 48084-1089 (800) 803-1164 Phone: (248) 643-0220 FAX: (248) 643-0259 Visit our web
More informationADVANCED OPERATOR PANEL (AOP)
ADVANCED OPERATOR PANEL (AOP) Operating Instructions Issue 04/02 English Contents 1 Warnings and Notes 3 1.1 Special Key Functions 4 2 Applications Examples 4 2.1 Single drive control using the AOP 4 2.2
More informationGETTING STARTED 5 WORKING WITH CUTTING DEVICE SETUPS 11 TABLE OF CONTENTS. Basic elements of your software 5. Setup area 6 Job area 6
TABLE OF CONTENTS 1 TABLE OF CONTENTS GETTING STARTED 5 Basic elements of your software 5 Toolbars 5 Setup area 6 Job area 6 Entering numerical values 6 Using spinner controls 6 Using built-in mathematical
More informationUPDATING THE SERVICE TOOL Updating the Service Tool with Prism 2
Updating the Service Tool with Prism 2 Updating the Modular Service Tool SD with Prism 2 Version 4.5.0 and higher The Modular Service Tool SD is equipped with the ability to update its software with the
More informationWebinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation
Webinar Organizers Joe Ryan Product Manager Precision Digital Corporation Ryan Shea Applications Specialist Precision Digital Corporation Bruce McDuffee Webinar Moderator Precision Digital Corporation
More informationRC-SV Configuration Guide Revision 3
Kramer Electronics, Ltd. RC-SV Configuration Guide Revision 3 Software Version 2.1.2.32 Intended for Kramer Technical Personnel or external System Integrators. To check that you have the latest version,
More informationOn occasion, due to a failure or water damage it may become necessary to replace an APEX, APEX LITE, or APEX JR with another controller.
Table of Contents INTRODUCTION... 3 REQUIREMENTS... 4 ACCESSING THE CLASSIC DASHBOARD... 7 CLONING YOUR APEX... 10 Create a configuration backup of the OLD APEX... 10 Prepare the NEW APEX... 11 Restore
More information1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically.
1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically. If setup does not launch, use Windows Explorer to navigate to the appropriate CD- ROM
More informationU90 Ladder Software Manual. Version 3.50, 6/03
U90 Ladder Software Manual Version 3.50, 6/03 Table Of Contents Welcome to U90 Ladder... 1 Program Editors... 1 Project Navigation Tree...1 Browse Sequences...1 Printing Documentation...2 Interface Language...
More information3700 SERIES USER MANUAL
SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with
More informationPRO-RTD Temperature Controller
PRO-RTD Temperature Controller 1 This quad channel RTD controller is ideal for numerous industrial temperature applications. It accepts direct sensor input from RTD 385, 392 and CU10 temperature probes.
More informationR7X CONFIGURATOR. (model: R7CON) Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax:
R7X CONFIGURATOR (model: R7CON) Users Manual 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 http://www.m-system.co.jp/ E-mail: info@m-system.co.jp R7CON
More informationINSTALLATION AND OPERATION MANUAL FOR ACC 070 COMM LINK RS485 TO PC INTERFACE AND PRISM SOFTWARE
SenTech Corporation 5745 Progress Road Indianapolis, Indiana 46241 888/248-1988 FAX 317/248-2014 INSTALLATION AND OPERATION MANUAL FOR ACC 070 COMM LINK RS485 TO PC INTERFACE AND PRISM SOFTWARE ii APPLICABILITY
More informationInstallation and operation manual ReciFlow Gas
Installation and operation manual ReciFlow Gas 1 1. Measurement principle... 3 2. Installation... 5 3. Operation... 7 4. Electrical interfaces... 11 5. Communication protocol... 14 6. Software update and
More informationThorViewer User Manual Version 3.6
ThorViewer User Manual Version 3.6 Requirements The PC must be running WindowsXP or newer with.net Framework 3.5 SP1. The.Net Framework 3.5 SP1 is available on the ThorPCX CD or on the Thor Guard Software
More informationThank you for choosing Loadstar Sensors. Need additional help? Call us at or us at
LoadVUE User Guide LoadVUE LoadVUE Lite Thank you for choosing Loadstar Sensors. Need additional help? Call us at 510-623-9600 or email us at support@loadstarsensors.com LoadVUE is compatible with Windows
More informationModbus. Interface. Description ISO 9001:2008
Certified Company 0110100010001010111000 Modbus 1010010101110101010100 Interface 1010101010101010101010 Description 1000110010101010001010 1010100101010010101000 0010101000110100101000 0010101111000101001000
More informationFlo-Ware. Discovering. Model 260/268 Flo-Tote System Manual. Version 3.1. Instrument & Data Management System for Windows 95,98 & NT
Discovering Flo-Ware TM Instrument & Data Management System for Windows 95,98 & NT Year 2000 Compliance Open System Instrument Communications Data Management Data Editing Presentation Quality Charts Text
More informationWaveWare Technologies, Inc. We Deliver Information at the Speed of Light. Enterprise Setup Manual and User Guide
WaveWare Technologies, Inc. We Deliver Information at the Speed of Light Enterprise Messaging Software Enterprise Setup Manual and User Guide WaveWare Website: www.wirelessmessaging.com Table of Contents
More informationMicrosoft Word - Templates
Microsoft Word - Templates Templates & Styles. Microsoft Word come will a large amount of predefined templates designed for you to use, it is also possible to download additional templates from web sites
More informationCenturion PLUS CPC4 Download Guide using C4 File Transfer Utility
1010537 2010-03-01 Section 50 Centurion PLUS CPC4 Download Guide using C4 File Transfer Utility 1.0 Background 1.1 The Centurion PLUS Control system consists of a Centurion PLUS Core (CPC4-1) and color
More information