1 CNI Inauguration Workshop Stanford, March 22 nd, 2012 High Fidelity Brain Connectivity Imaging -Recent Progress on Diffusion Weighted MRI for High Resolution and Low Distortion Allen W. Song, PhD Brain Imaging and Analysis Center Duke University
2 The Need for High Resolution and Low Distortion to Image Connectivity Brain as an Example: >100 Billion Neurons >1 Trillion Connections >7 Billions Brains
3 What Resolution Should We Reach with Diffusion Weighted MRI? High Angular Resolution Solves Crossing Fibers without Demand on Spatial Resolution High Spatial Resolution Is Needed for U-fibersU
4 What Resolution Should We Reach with Diffusion Weighted MRI? High-Resolution Susceptibility Imaging Guidon,, Liu, et al., Duke diamagnetic 0 paramagnetic WM/GM mm into Interface GM WM
5 Benefit of High-Resolution Diffusion MRI High-Res FA 1 mm 3 ROIs 1x1x1 mm 3 2x2x2 mm 3 3x3x3 mm 3 2x2x2 mm 3 1x1x1 mm 3 High-Resolution DTI Liu et al., Duke
6 Benefit of High-Resolution Diffusion MRI Region FA 234 3x3x3mm 3 2x2x2mm 3 1x1x1mm 3 0 High-Resolution DTI Guidon et al., Duke
7 High Resolution DWI Is Not So Easy. At the present time, the only viable solution to achieve high-resolution DWI is through multi-shot acquisition Two-shot DW EPI Two-shot DW Spiral
8 Self-Navigated Interleaved Spiral (SNAILS) To Remove Aliasing Artifacts bo b1 b2 Baseline Image Diffusion Weighting Images But it requires specialized pulse sequence, as well as additional scan and reconstruction time Liu et al., BIAC, Duke University
9 Goal: To develop efficient, effective, and practical acquisition/reconstruction methods for high- fidelity DWI. Criteria: Ideally, the methodology should require minimal pulse sequence changes, remove the need for additional reference scans, and still result in high-quality DW images.
10 Cycling-Phase Reconstruction (CPR) A general post-processing processing framework designed to correct for hardware- and subject-induced aliasing artifacts in accelerated MRI scans (EPI, Spiral, Propeller, FSE, GRASE among others), without reference scans Also applicable to diffusion weighted single-shot shot / multi-shot / parallel EPI, Spiral, and Propeller acquisitions, without reference scans
11 CPR for 2D EPI Intensity Profile Sorted Profile Cost Function Chen et al.,magn Reson Med Oct;66(4):
12 CPR for 2D EPI Chen et al.,magn Reson Med Oct;66(4):
13 No Correction 1-D D Reference CPR 1-Shot 2-Shot 3-Shot 4-Shot EPI Chen et al.,magn Reson Med Oct;66(4):
14 Can CPR Work in Spiral Imaging? a: b=0 image b: image (a) with simulated phase error d: background energy in images (c) as a function of φ 0 and g x c: image (b) reconstructed by cycling phases with different φ 0 and g x values the image with the minimum background energy is the one with the least aliasing Truong et al. (in press) Magn. Reson. Med.
15 CPR for Two-Shot DW Spiral Imaging shot 1 aliased images k-space trajectory point spread function (N x 0 +1:2N x 0, N y 0 +1:2N y 0 ) motioninduced phase error known unaliased image unknown shot 2 a 1 a 2 P 11 = Eq. [1] e iφ P 2N 2 e iφ P 21 P 1N 2 u 1 u n u N 2 The 2 nd row of E contains the motion-induced phase term exp[ iφ(x 0, y 0 )]
16 CPR for Two-Shot DW Spiral Imaging φ is assumed to be spatially linear: φ(x, y) = φ 0 + xg x + yg y which is sufficient to correct for rigid-body motion* A series of images are reconstructed by solving Eq. [1] with different φ 0, g x, and g y values S background φ 0 / g x / g y min The final image is chosen as the one with the lowest signal intensity in the background, i.e., with the least amount of aliasing *Anderson & Gore (1994) MRM 32:
17 CPR Improves Diffusion Weighted Multi-Shot High-Resolution Spiral Imaging uncorrected DWI images corrected DWI images uncorrected ADC maps corrected ADC maps Truong et al. (in press) Magn. Reson. Med.
18 CPR Improves Diffusion Weighted Multi-Shot EPI After Correction Improvement in two-shot DW-EPI
19 CPR Improves Four-Shot DW EPI Original Images with Reference Echoes Original Image with Reference Echoes Improved Image after CPR
20 Geometric Distortion is Another Major Challenge for High-Resolution DWI Distortion usually proportional to the readout window length 160ms 128 echoes 2.5 mm 3 320mm 100ms 64 echoes SENSE Acceleration Factor mm 3 320mm
21 EPI Distortions from Static Bo Inhomogeneity
22 DW EPI Distortions from Dynamic Eddy Current DW EPI DW Spiral
23 Mapping Eddy Current Induced Field Changes Truong et al., NeuroImage Aug 15;57(4):1343-7
24 Field Map Based Distortion Correction Truong et al., NeuroImage Aug 15;57(4):1343-7
25 Field Map Based Deblurring in Spiral Imaging [0.00, 0.00, 0.00] [0.79, 0.32, 0.51] [ 0.66, 0.16, 0.72] bo Diffusion Direction #1 Diffusion Direction #2 Avram et al., ISMRM 2011
26 Can We Make Field Map Generation Inherent? Echo-shifting effect in EPI Chen et al., Neuroimage. 2006; 31(2): Truong et al., Magn. Reson. Med. 2010; 64:1121-7
27 Inherent Field Mapping based on K-space Energy Spectrum Analysis (KESA) Chen et al., Neuroimage. 2006; 31(2): Truong et al., Magn. Reson. Med. 2010; 64:1121-7
28 Echo-Shifting Effect in DTI
29 Magnetic Field Maps in DTI
30 Summary A practical yet powerful technical foundation for improved DWI / DTI acquisition and reconstruction strategies Inherent correction for ghosting artifacts using cycling phase reconstruction (CPR) without the need for potentially time-consuming reference echoes in high-resolution DWI Dynamic distortion correction based on inherently generated field maps to restore spatial fidelity Generally applicable to all fast imaging techniques including EPI, Spiral, Propeller, and other k-space k trajectories
31 Acknowledgement Nan-Kuei Chen Alex Avram Chunlei Liu Arnaud Guidon Todd Harshbarger Ana Batrachenko Trong-Kha Truong NS , EB , NS Faculty and Staff at the Duke UNC Brain Imaging and Analysis Center at Duke University
Head motion in diffusion MRI
Head motion in diffusion MRI Anastasia Yendiki HMS/MGH/MIT Athinoula A. Martinos Center for Biomedical Imaging 11/06/13 Head motion in diffusion MRI 0/33 Diffusion contrast Basic principle of diffusion
More informationRole of Parallel Imaging in High Field Functional MRI
Role of Parallel Imaging in High Field Functional MRI Douglas C. Noll & Bradley P. Sutton Department of Biomedical Engineering, University of Michigan Supported by NIH Grant DA15410 & The Whitaker Foundation
More informationDiffusion MRI Acquisition. Karla Miller FMRIB Centre, University of Oxford
Diffusion MRI Acquisition Karla Miller FMRIB Centre, University of Oxford karla@fmrib.ox.ac.uk Diffusion Imaging How is diffusion weighting achieved? How is the image acquired? What are the limitations,
More informationRemoval of EPI Nyquist Ghost Artifacts With Two- Dimensional Phase Correction
Removal of EPI Nyquist Ghost Artifacts With Two- Dimensional Phase Correction Nan-kuei Chen 1,5 and Alice M. Wyrwicz 4 * Magnetic Resonance in Medicine 51:147 153 (004) Odd even echo inconsistencies result
More informationBDP: BrainSuite Diffusion Pipeline. Chitresh Bhushan
BDP: BrainSuite Diffusion Pipeline Chitresh Bhushan Why diffusion MRI? T 2 weighted MPRAGE FA map Fiber track Quantify microstructural tissue characteristics Structural connectivity Connectome Clinical
More informationCorrection for EPI Distortions Using Multi-Echo Gradient-Echo Imaging
Correction for EPI Distortions Using Multi-Echo Gradient-Echo Imaging Nan-kuei Chen and Alice M. Wyrwicz* Magnetic Resonance in Medicine 41:1206 1213 (1999) A novel and effective technique is described
More informationHST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008
MIT OpenCourseWare http://ocw.mit.edu HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms.
More informationSuper-Resolution Reconstruction of Diffusion-Weighted Images from Distortion Compensated Orthogonal Anisotropic Acquisitions.
Super-Resolution Reconstruction of Diffusion-Weighted Images from Distortion Compensated Orthogonal Anisotropic Acquisitions. Benoit Scherrer Ali Gholipour Simon K. Warfield Children s Hospital Boston,
More informationARTICLE IN PRESS YNIMG-03684; No. of pages: 14; 4C:
YNIMG-03684; No. of pages: 14; 4C: DTD 5 Technical note Application of k-space energy spectrum analysis to susceptibility field mapping and distortion correction in gradient-echo EPI Nan-kuei Chen, a,
More informationSteen Moeller Center for Magnetic Resonance research University of Minnesota
Steen Moeller Center for Magnetic Resonance research University of Minnesota moeller@cmrr.umn.edu Lot of material is from a talk by Douglas C. Noll Department of Biomedical Engineering Functional MRI Laboratory
More informationField Maps. 1 Field Map Acquisition. John Pauly. October 5, 2005
Field Maps John Pauly October 5, 25 The acquisition and reconstruction of frequency, or field, maps is important for both the acquisition of MRI data, and for its reconstruction. Many of the imaging methods
More informationAutomatic Gradient Preemphasis Adjustment: A 15-Minute Journey to Improved Diffusion-Weighted Echo-Planar Imaging
Automatic Gradient Preemphasis Adjustment: A 15-Minute Journey to Improved Diffusion-Weighted Echo-Planar Imaging Vincent J. Schmithorst* and Bernard J. Dardzinski Magnetic Resonance in Medicine 47:208
More informationParallel Magnetic Resonance Imaging (pmri): How Does it Work, and What is it Good For?
Parallel Magnetic Resonance Imaging (pmri): How Does it Work, and What is it Good For? Nathan Yanasak, Ph.D. Chair, AAPM TG118 Department of Radiology Georgia Regents University Overview Phased-array coils
More informationHST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008
MIT OpenCourseWare http://ocw.mit.edu HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms.
More informationMRI Physics II: Gradients, Imaging
MRI Physics II: Gradients, Imaging Douglas C., Ph.D. Dept. of Biomedical Engineering University of Michigan, Ann Arbor Magnetic Fields in MRI B 0 The main magnetic field. Always on (0.5-7 T) Magnetizes
More informationK-Space Trajectories and Spiral Scan
K-Space and Spiral Scan Presented by: Novena Rangwala nrangw2@uic.edu 1 Outline K-space Gridding Reconstruction Features of Spiral Sampling Pulse Sequences Mathematical Basis of Spiral Scanning Variations
More informationBasic fmri Design and Analysis. Preprocessing
Basic fmri Design and Analysis Preprocessing fmri Preprocessing Slice timing correction Geometric distortion correction Head motion correction Temporal filtering Intensity normalization Spatial filtering
More informationEPI Data Are Acquired Serially. EPI Data Are Acquired Serially 10/23/2011. Functional Connectivity Preprocessing. fmri Preprocessing
Functional Connectivity Preprocessing Geometric distortion Head motion Geometric distortion Head motion EPI Data Are Acquired Serially EPI Data Are Acquired Serially descending 1 EPI Data Are Acquired
More informationFunctional MRI in Clinical Research and Practice Preprocessing
Functional MRI in Clinical Research and Practice Preprocessing fmri Preprocessing Slice timing correction Geometric distortion correction Head motion correction Temporal filtering Intensity normalization
More informationSPM8 for Basic and Clinical Investigators. Preprocessing
SPM8 for Basic and Clinical Investigators Preprocessing fmri Preprocessing Slice timing correction Geometric distortion correction Head motion correction Temporal filtering Intensity normalization Spatial
More informationSPM8 for Basic and Clinical Investigators. Preprocessing. fmri Preprocessing
SPM8 for Basic and Clinical Investigators Preprocessing fmri Preprocessing Slice timing correction Geometric distortion correction Head motion correction Temporal filtering Intensity normalization Spatial
More informationSources of Distortion in Functional MRI Data
Human Brain Mapping 8:80 85(1999) Sources of Distortion in Functional MRI Data Peter Jezzard* and Stuart Clare FMRIB Centre, Department of Clinical Neurology, University of Oxford, Oxford, UK Abstract:
More informationBDP: BrainSuite Diffusion Pipeline. Chitresh Bhushan
BDP: BrainSuite Diffusion Pipeline Chitresh Bhushan Why diffusion MRI? T 2 weighted MPRAGE FA map Fiber track Quantify microstructural tissue characteristics Structural connectivity Connectome Clinical
More informationSlide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.
Slide 1 Technical Aspects of Quality Control in Magnetic Resonance Imaging Slide 2 Compliance Testing of MRI Systems, Ph.D. Department of Radiology Henry Ford Hospital, Detroit, MI Slide 3 Compliance Testing
More informationWhat is pmri? Overview. The Need for Speed: A Technical and Clinical Primer for Parallel MR Imaging 8/1/2011
The Need for Speed: A Technical and Clinical Primer for Parallel MR Imaging Nathan Yanasak, Ph.D. Chair, AAPM TG118 Assistant Professor Department of Radiology Director, Core Imaging Facility for Small
More information3D Steady-State Diffusion-Weighted Imaging with Trajectory Using Radially Batched Internal Navigator Echoes (TURBINE)
3D Steady-State Diffusion-Weighted Imaging with Trajectory Using Radially Batched Internal Navigator Echoes (TURBINE) Jennifer A. McNab, Daniel Gallichan, Karla L. Miller Oxford Centre for Functional Magnetic
More informationM R I Physics Course
M R I Physics Course Multichannel Technology & Parallel Imaging Nathan Yanasak, Ph.D. Jerry Allison Ph.D. Tom Lavin, B.S. Department of Radiology Medical College of Georgia References: 1) The Physics of
More informationComprehensive Approach for Correction of Motion and Distortion in Diffusion-Weighted MRI
Magnetic Resonance in Medicine 51:103 114 (2004) Comprehensive Approach for Correction of Motion and Distortion in Diffusion-Weighted MRI G.K. Rohde, 1,3 * A.S. Barnett, 2 P.J. Basser, 1 S. Marenco, 2
More information(a Scrhon5 R2iwd b. P)jc%z 5. ivcr3. 1. I. ZOms Xn,s. 1E IDrAS boms. EE225E/BIOE265 Spring 2013 Principles of MRI. Assignment 8 Solutions
EE225E/BIOE265 Spring 2013 Principles of MRI Miki Lustig Assignment 8 Solutions 1. Nishimura 7.1 P)jc%z 5 ivcr3. 1. I Due Wednesday April 10th, 2013 (a Scrhon5 R2iwd b 0 ZOms Xn,s r cx > qs 4-4 8ni6 4
More informationSampling, Ordering, Interleaving
Sampling, Ordering, Interleaving Sampling patterns and PSFs View ordering Modulation due to transients Temporal modulations Slice interleaving Sequential, Odd/even, bit-reversed Arbitrary Other considerations:
More informationHST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008
MIT OpenCourseWare http://ocw.mit.edu HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms.
More informationParallel Imaging. Marcin.
Parallel Imaging Marcin m.jankiewicz@gmail.com Parallel Imaging initial thoughts Over the last 15 years, great progress in the development of pmri methods has taken place, thereby producing a multitude
More informationMotion Artifacts and Suppression in MRI At a Glance
Motion Artifacts and Suppression in MRI At a Glance Xiaodong Zhong, PhD MR R&D Collaborations Siemens Healthcare MRI Motion Artifacts and Suppression At a Glance Outline Background Physics Common Motion
More information2. Creating Field Maps Using the Field Map GUI (Version 2.0) in SPM5
1. Introduction This manual describes how to use the Field Map Toolbox Version 2.0 for creating unwrapped field maps that can be used to do geometric distortion correction of EPI images in SPM5. 1. 1.
More informationFmri Spatial Processing
Educational Course: Fmri Spatial Processing Ray Razlighi Jun. 8, 2014 Spatial Processing Spatial Re-alignment Geometric distortion correction Spatial Normalization Smoothing Why, When, How, Which Why is
More informationHigh Spatial Resolution EPI Using an Odd Number of Interleaves
Magnetic Resonance in Medicine 41:1199 1205 (1999) High Spatial Resolution EPI Using an Odd Number of Interleaves Michael H. Buonocore* and David C. Zhu Ghost artifacts in echoplanar imaging (EPI) arise
More informationMotion Robust Magnetic Susceptibility and Field Inhomogeneity Estimation Using Regularized Image Restoration Techniques for fmri
Motion Robust Magnetic Susceptibility and Field Inhomogeneity Estimation Using Regularized Image Restoration Techniques for fmri Desmond Tec Beng Yeo 1,, Jeffrey A. Fessler 1,, and Bolye Kim 1 1 Department
More informationC. Leon Partain JOURNAL OF MAGNETIC RESONANCE IMAGING EDITOR-IN-CHIEF
JOURNAL OF MAGNETIC RESONANCE IMAGING ri m j / m o c. E ning M C ear l lth a he li ey w w. w w VOLUME 37 NUMBER 6 JUNE 2013 VOLUME 37 NUMBER 6 JUNE 2013 PAGES 1257 1504 CORRECTION OF EDDY CURRENT DISTORTIONS
More informationNIH Public Access Author Manuscript Med Image Comput Comput Assist Interv. Author manuscript; available in PMC 2009 December 4.
NIH Public Access Author Manuscript Med Image Comput Comput Assist Interv. Author manuscript; available in PMC 2009 December 4. Published in final edited form as: Med Image Comput Comput Assist Interv.
More informationCompressed Sensing for Rapid MR Imaging
Compressed Sensing for Rapid Imaging Michael Lustig1, Juan Santos1, David Donoho2 and John Pauly1 1 Electrical Engineering Department, Stanford University 2 Statistics Department, Stanford University rapid
More informationModule 4. K-Space Symmetry. Review. K-Space Review. K-Space Symmetry. Partial or Fractional Echo. Half or Partial Fourier HASTE
MRES 7005 - Fast Imaging Techniques Module 4 K-Space Symmetry Review K-Space Review K-Space Symmetry Partial or Fractional Echo Half or Partial Fourier HASTE Conditions for successful reconstruction Interpolation
More informationADVANCED RECONSTRUCTION TECHNIQUES IN MRI - 2
ADVANCED RECONSTRUCTION TECHNIQUES IN MRI - 2 Presented by Rahil Kothari PARTIAL FOURIER RECONSTRUCTION WHAT IS PARTIAL FOURIER RECONSTRUCTION? In Partial Fourier Reconstruction data is not collected symmetrically
More informationWhite Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space
White Pixel Artifact Caused by a noise spike during acquisition Spike in K-space sinusoid in image space Susceptibility Artifacts Off-resonance artifacts caused by adjacent regions with different
More informationFunctional MRI. Jerry Allison, Ph. D. Medical College of Georgia
Functional MRI Jerry Allison, Ph. D. Medical College of Georgia BOLD Imaging Technique Blood Oxygen Level Dependent contrast can be used to map brain function Right Hand Motor Task Outline fmri BOLD Contrast
More informationAutomatic Correction of Echo-Planar Imaging (EPI) Ghosting Artifacts in Real-Time Interactive Cardiac MRI Using Sensitivity Encoding
JOURNAL OF MAGNETIC RESONANCE IMAGING 27:239 245 (2008) Technical Note Automatic Correction of Echo-Planar Imaging (EPI) Ghosting Artifacts in Real-Time Interactive Cardiac MRI Using Sensitivity Encoding
More informationRobust EPI Nyquist Ghost Removal by Incorporating Phase Error Correction With Sensitivity Encoding (PEC-SENSE)
NOTE Magnetic Resonance in Medicine 00:00 00 (017) Robust EPI Nyquist Ghost Removal by Incorporating Phase Error Correction With Sensitivity Encoding (PEC-SENSE) Victor B. Xie, 1,y Mengye Lyu, 1,y Yilong
More informationFiber Selection from Diffusion Tensor Data based on Boolean Operators
Fiber Selection from Diffusion Tensor Data based on Boolean Operators D. Merhof 1, G. Greiner 2, M. Buchfelder 3, C. Nimsky 4 1 Visual Computing, University of Konstanz, Konstanz, Germany 2 Computer Graphics
More informationPartial k-space Reconstruction
Chapter 2 Partial k-space Reconstruction 2.1 Motivation for Partial k- Space Reconstruction a) Magnitude b) Phase In theory, most MRI images depict the spin density as a function of position, and hence
More informationMotion Correction in fmri by Mapping Slice-to-Volume with Concurrent Field-Inhomogeneity Correction
Motion Correction in fmri by Mapping Slice-to-Volume with Concurrent Field-Inhomogeneity Correction Desmond T.B. Yeo 1,2, Jeffery A. Fessler 2, and Boklye Kim 1 1 Department of Radiology, University of
More informationPartial k-space Recconstruction
Partial k-space Recconstruction John Pauly September 29, 2005 1 Motivation for Partial k-space Reconstruction a) Magnitude b) Phase In theory, most MRI images depict the spin density as a function of position,
More informationFast Imaging UCLA. Class Business. Class Business. Daniel B. Ennis, Ph.D. Magnetic Resonance Research Labs. Tuesday (3/7) from 6-9pm HW #1 HW #2
Fast Imaging Daniel B. Ennis, Ph.D. Magnetic Resonance Research Labs Class Business Tuesday (3/7) from 6-9pm 6:00-7:30pm Groups Avanto Sara Said, Yara Azar, April Pan Skyra Timothy Marcum, Diana Lopez,
More informationHST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008
MIT OpenCourseWare http://ocw.mit.edu HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms.
More informationMRI Hot Topics Motion Correction for MR Imaging. medical
MRI Hot Topics Motion Correction for MR Imaging s medical Motion Correction for MR Imaging Kyle A. Salem, PhD Motion Artifacts in a Clinical Setting Patient motion is probably the most common cause of
More informationOrigin and Minimization of Residual Motion-Related Artifacts in Navigator-Corrected Segmented Diffusion-Weighted EPI of the Human Brain
Magnetic Resonance in Medicine 47:818 822 (2002) DOI 10.1002/mrm.10102 Origin and Minimization of Residual Motion-Related Artifacts in Navigator-Corrected Segmented Diffusion-Weighted EPI of the Human
More informationNoise and Artifacts in FMRI
Noise and Artifacts in FMRI Instructor: Luis Hernandez-Garcia, Ph.D. Associate Research Professor FMRI Laboratory, Biomedical Engineering FMRI analysis - synopsis of what you ll do next week 1. Formulate
More informationConstrained Reconstruction of Sparse Cardiac MR DTI Data
Constrained Reconstruction of Sparse Cardiac MR DTI Data Ganesh Adluru 1,3, Edward Hsu, and Edward V.R. DiBella,3 1 Electrical and Computer Engineering department, 50 S. Central Campus Dr., MEB, University
More informationarxiv: v1 [physics.med-ph] 7 Jan 2019
SMS MUSSELS: A NAVIGATOR-FREE RECONSTRUCTION FOR SIMULTANEOUS MULTISLICE ACCELERATED MULTISHOT DIFFUSION WEIGHTED IMAGING arxiv:1901.01893v1 [physics.med-ph] 7 Jan 2019 Merry Mani 1, Mathews Jacob 2, Graeme
More informationThe SIMRI project A versatile and interactive MRI simulator *
COST B21 Meeting, Lodz, 6-9 Oct. 2005 The SIMRI project A versatile and interactive MRI simulator * H. Benoit-Cattin 1, G. Collewet 2, B. Belaroussi 1, H. Saint-Jalmes 3, C. Odet 1 1 CREATIS, UMR CNRS
More informationMultishot Diffusion-Weighted FSE Using PROPELLER MRI
Multishot Diffusion-Weighted FSE Using PROPELLER MRI James G. Pipe, 1 * Victoria G. Farthing, 1 and Kirsten P. Forbes 2 Magnetic Resonance in Medicine 47:42 52 (2002) A method for obtaining diffusion-weighted
More informationFast Imaging Trajectories: Non-Cartesian Sampling (1)
Fast Imaging Trajectories: Non-Cartesian Sampling (1) M229 Advanced Topics in MRI Holden H. Wu, Ph.D. 2018.05.03 Department of Radiological Sciences David Geffen School of Medicine at UCLA Class Business
More informationDiffusion model fitting and tractography: A primer
Diffusion model fitting and tractography: A primer Anastasia Yendiki HMS/MGH/MIT Athinoula A. Martinos Center for Biomedical Imaging 03/18/10 Why n how Diffusion model fitting and tractography 0/18 Why
More informationDynamic Image and Fieldmap Joint Estimation Methods for MRI Using Single-Shot Trajectories
Dynamic Image and Fieldmap Joint Estimation Methods for MRI Using Single-Shot Trajectories by Antonis Matakos A dissertation submitted in partial fulfillment of the requirements for the degree of Doctor
More informationCorrection of Partial Volume Effects in Arterial Spin Labeling MRI
Correction of Partial Volume Effects in Arterial Spin Labeling MRI By: Tracy Ssali Supervisors: Dr. Keith St. Lawrence and Udunna Anazodo Medical Biophysics 3970Z Six Week Project April 13 th 2012 Introduction
More informationLilla Zöllei A.A. Martinos Center, MGH; Boston, MA
Lilla Zöllei lzollei@nmr.mgh.harvard.edu A.A. Martinos Center, MGH; Boston, MA Bruce Fischl Gheorghe Postelnicu Jean Augustinack Anastasia Yendiki Allison Stevens Kristen Huber Sita Kakonoori + the FreeSurfer
More informationCOBRE Scan Information
COBRE Scan Information Below is more information on the directory structure for the COBRE imaging data. Also below are the imaging parameters for each series. Directory structure: var/www/html/dropbox/1139_anonymized/human:
More informationFast iterative algorithm for the reconstruction of multi-shot non-cartesian diffusion data
Fast iterative algorithm for the reconstruction of multi-shot non-cartesian diffusion data Merry Mani 1, Mathews Jacob 2, Vincent Magnotta 3, Jianhui Zhong 4 1 Department of Electrical and Computer Engineering,
More informationReferenceless Interleaved Echo-Planar Imaging
Referenceless Interleaved Echo-Planar Imaging Magnetic Resonance in Medicine 41:87 94 (1999) Scott B. Reeder, 1 Ergin Atalar, * Anthony Z. Faranesh, 1 and Elliot R. McVeigh 1, Interleaved echo-planar imaging
More informationModule 5: Dynamic Imaging and Phase Sharing. (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review. Improving Temporal Resolution.
MRES 7005 - Fast Imaging Techniques Module 5: Dynamic Imaging and Phase Sharing (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review Improving Temporal Resolution True-FISP (I) True-FISP (II) Keyhole
More informationSingle Breath-hold Abdominal T 1 Mapping using 3-D Cartesian Sampling and Spatiotemporally Constrained Reconstruction
Single Breath-hold Abdominal T 1 Mapping using 3-D Cartesian Sampling and Spatiotemporally Constrained Reconstruction Felix Lugauer 1,3, Jens Wetzl 1, Christoph Forman 2, Manuel Schneider 1, Berthold Kiefer
More informationClassification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging
1 CS 9 Final Project Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging Feiyu Chen Department of Electrical Engineering ABSTRACT Subject motion is a significant
More informationMRI Reconstruction using Real-Time Motion Tracking: A Simulation Study
MRI Reconstruction using Real-Time Motion Tracking: A Simulation Study Jeff Orchard David R. Cheriton School of Computer Science University of Waterloo Waterloo, ON Canada, N2L 3G1 e-mail: jorchard@uwaterloo.ca
More informationPre-processing of ASL data T CT
Wed October 2, 2013 Image Processing Pre-processing: motion correction, denoising, outlier detection Alessandra Bertoldo Pre-processing of ASL data T CT C T C Single TI ASL T T T T C CCC average Pre-processing
More informationHST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2006
MIT OpenCourseWare http://ocw.mit.edu HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2006 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms.
More informationMRI image formation 8/3/2016. Disclosure. Outlines. Chen Lin, PhD DABR 3. Indiana University School of Medicine and Indiana University Health
MRI image formation Indiana University School of Medicine and Indiana University Health Disclosure No conflict of interest for this presentation 2 Outlines Data acquisition Spatial (Slice/Slab) selection
More informationNIH Public Access Author Manuscript Magn Reson Med. Author manuscript; available in PMC 2012 June 04.
NIH Public Access Author Manuscript Published in final edited form as: Magn Reson Med. 2011 June ; 65(6): 1532 1556. doi:10.1002/mrm.22924. Diffusion Tensor Imaging and Beyond Jacques-Donald Tournier 1,
More informationA Ray-based Approach for Boundary Estimation of Fiber Bundles Derived from Diffusion Tensor Imaging
A Ray-based Approach for Boundary Estimation of Fiber Bundles Derived from Diffusion Tensor Imaging M. H. A. Bauer 1,3, S. Barbieri 2, J. Klein 2, J. Egger 1,3, D. Kuhnt 1, B. Freisleben 3, H.-K. Hahn
More informationAdvanced MRI Techniques (and Applications)
Advanced MRI Techniques (and Applications) Jeffry R. Alger, PhD Department of Neurology Ahmanson-Lovelace Brain Mapping Center Brain Research Institute Jonsson Comprehensive Cancer Center University of
More informationAn Iterative Approach for Reconstruction of Arbitrary Sparsely Sampled Magnetic Resonance Images
An Iterative Approach for Reconstruction of Arbitrary Sparsely Sampled Magnetic Resonance Images Hamed Pirsiavash¹, Mohammad Soleymani², Gholam-Ali Hossein-Zadeh³ ¹Department of electrical engineering,
More informationImproved Spatial Localization in 3D MRSI with a Sequence Combining PSF-Choice, EPSI and a Resolution Enhancement Algorithm
Improved Spatial Localization in 3D MRSI with a Sequence Combining PSF-Choice, EPSI and a Resolution Enhancement Algorithm L.P. Panych 1,3, B. Madore 1,3, W.S. Hoge 1,3, R.V. Mulkern 2,3 1 Brigham and
More informationAbbie M. Diak, PhD Loyola University Medical Center Dept. of Radiation Oncology
Abbie M. Diak, PhD Loyola University Medical Center Dept. of Radiation Oncology Outline High Spectral and Spatial Resolution MR Imaging (HiSS) What it is How to do it Ways to use it HiSS for Radiation
More informationJoint estimation and correction of geometric distortions for EPI functional MRI using harmonic retrieval
Joint estimation and correction of geometric distortions for EPI functional MRI using harmonic retrieval The MIT Faculty has made this article openly available. Please share how this access benefits you.
More informationGE Healthcare CLINICAL GALLERY. Discovery * MR750w 3.0T. This brochure is intended for European healthcare professionals.
GE Healthcare CLINICAL GALLERY Discovery * MR750w 3.0T This brochure is intended for European healthcare professionals. NEURO PROPELLER delivers high resolution, motion insensitive imaging in all planes.
More informationIMAGE reconstruction in conventional magnetic resonance
IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 24, NO. 3, MARCH 2005 325 Conjugate Phase MRI Reconstruction With Spatially Variant Sample Density Correction Douglas C. Noll*, Member, IEEE, Jeffrey A. Fessler,
More informationSampling, Ordering, Interleaving
Sampling, Ordering, Interleaving Sampling patterns and PSFs View ordering Modulation due to transients Temporal modulations Timing: cine, gating, triggering Slice interleaving Sequential, Odd/even, bit-reversed
More informationUCLA UCLA Previously Published Works
UCLA UCLA Previously Published Works Title Eddy current-nulled convex optimized diffusion encoding (EN-CODE) for distortion-free diffusion tensor imaging with short echo times. Permalink https://escholarship.org/uc/item/0dn450j1
More informationQuantitative MRI of the Brain: Investigation of Cerebral Gray and White Matter Diseases
Quantities Measured by MR - Quantitative MRI of the Brain: Investigation of Cerebral Gray and White Matter Diseases Static parameters (influenced by molecular environment): T, T* (transverse relaxation)
More informationClinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis
Clinical Importance Rapid cardiovascular flow quantitation using sliceselective Fourier velocity encoding with spiral readouts Valve disease affects 10% of patients with heart disease in the U.S. Most
More informationThis Time. fmri Data analysis
This Time Reslice example Spatial Normalization Noise in fmri Methods for estimating and correcting for physiologic noise SPM Example Spatial Normalization: Remind ourselves what a typical functional image
More informationIntroduction to fmri. Pre-processing
Introduction to fmri Pre-processing Tibor Auer Department of Psychology Research Fellow in MRI Data Types Anatomical data: T 1 -weighted, 3D, 1/subject or session - (ME)MPRAGE/FLASH sequence, undistorted
More informationUse of MRI in Radiotherapy: Technical Consideration
Use of MRI in Radiotherapy: Technical Consideration Yanle Hu, PhD Department of Radiation Oncology, Mayo Clinic Arizona 04/07/2018 2015 MFMER slide-1 Conflict of Interest: None 2015 MFMER slide-2 Objectives
More informationInformation about presenter
Information about presenter 2013-now Engineer R&D ithera Medical GmbH 2011-2013 M.Sc. in Biomedical Computing (TU München) Thesis title: A General Reconstruction Framework for Constrained Optimisation
More informationRelease Notes. Multi-Band EPI C2P. Release HCP_v1 10 February 2014
Release Notes Multi-Band EPI C2P Release HCP_v1 10 February 2014 Installation 1. Restart the system (reboot host and MRIR) 2. Extract the.zip file to a temporary directory 3. Run the installer.bat file
More informationSpread Spectrum Using Chirp Modulated RF Pulses for Incoherent Sampling Compressive Sensing MRI
Spread Spectrum Using Chirp Modulated RF Pulses for Incoherent Sampling Compressive Sensing MRI Sulaiman A. AL Hasani Department of ECSE, Monash University, Melbourne, Australia Email: sulaiman.alhasani@monash.edu
More informationDynamic Contrast enhanced MRA
Dynamic Contrast enhanced MRA Speaker: Yung-Chieh Chang Date : 106.07.22 Department of Radiology, Taichung Veterans General Hospital, Taichung, Taiwan 1 Outline Basic and advanced principles of Diffusion
More informationBody Diffusion MRI: Basics and Beyond
What is Diffusion? The process of Brownian motion Body Diffusion MRI: Basics and Beyond Xiaodong Zhong, PhD Senior R&D Expert, MR R&D Collaborations, Siemens Healthcare Adjunct Assistant Professor, Radiologyand
More informationdesign as a constrained maximization problem. In principle, CODE seeks to maximize the b-value, defined as, where
Optimal design of motion-compensated diffusion gradient waveforms Óscar Peña-Nogales 1, Rodrigo de Luis-Garcia 1, Santiago Aja-Fernández 1,Yuxin Zhang 2,3, James H. Holmes 2,Diego Hernando 2,3 1 Laboratorio
More informationJoint Reconstruction of Multi-contrast MR Images for Multiple Sclerosis Lesion Segmentation
Joint Reconstruction of Multi-contrast MR Images for Multiple Sclerosis Lesion Segmentation Pedro A Gómez 1,2,3, Jonathan I Sperl 3, Tim Sprenger 2,3, Claudia Metzler-Baddeley 4, Derek K Jones 4, Philipp
More informationProspective Motion Correction in Brain Imaging: A Review
IMAGING METHODOLOGY - Review Magnetic Resonance in Medicine 69:621 636 (2013) Prospective Motion Correction in Brain Imaging: A Review Julian Maclaren, 1,2 * Michael Herbst, 1 Oliver Speck, 3 and Maxim
More informationFunctional analysis with DTI and diffusion-neurography of cranial nerves
Functional analysis with DTI and diffusion-neurography of cranial nerves Poster No.: C-1942 Congress: ECR 2013 Type: Educational Exhibit Authors: J. P. Martínez Barbero, T. Martín Noguerol, A. Luna Alcalá;
More information8/11/2009. Common Areas of Motion Problem. Motion Compensation Techniques and Applications. Type of Motion. What s your problem
Common Areas of Motion Problem Motion Compensation Techniques and Applications Abdominal and cardiac imaging. Uncooperative patient, such as pediatric. Dynamic imaging and time series. Chen Lin, PhD Indiana
More information