1.6 WT 60 BASE 2004/108/EC (EMC) - EN

Size: px
Start display at page:

Download "1.6 WT 60 BASE 2004/108/EC (EMC) - EN"

Transcription

1 Microlectra bv. Hermanus Boerhaavestraat ME Oud-Beijerland. Netherlands. Tel 31(0) Fax 31(0) Installation user s manual version 1.6 WT 60 BASE 2004/108/EC (EMC) - EN :2001 INSTRUMENT IDENTIFICATION

2 SYMBOLS The following symbols are used in the manual to draw the reader s attention to important points: Caution! Risk of electric shock! Caution! This operation must be performed by specialist personnel. Pay particular attention to the following points. Further information. GUARANTEE 24 months from the delivery document date. The guarantee covers only defected parts and includes the replacement parts and labour. All shipping and packing costs are paid by the customer. It is possible to have the repair in guarantee on condition that the returned product has not been transformed, damaged or repaired without authorization. No guarantee is applicable on returned products without the original label and/or serial number. No guarantee against misuse. Batteries: Laumas provides 1 year guarantee from the date of delivery note, against material defects or battery manufacturing faults. Disposal of Waste Equipment by Users in Private Household in the European Union This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at this time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the reseller.

3 TABLE OF CONTENTS RECOMMENDATIONS FOR CORRECT INSTALLATION... 1 INSTRUMENT OPERATION... 1 TECHNICAL FEATURES... 2 ELECTRICAL CONNECTIONS CHANGING VOLTAGE 230 / 115 VAC... 4 STARTING PROCESS... 5 TARE ZERO-SETTING... 5 INSTRUMENT ALREADY CALIBRATED IN LABORATORY... 6 INSTRUMENT NOT CALIBRATED... 7 THEORICAL CALIBRATION... 8 CALIBRATION WITH CALIBRATING WEIGHT... 9 SET POINT AND HYSTERESIS PROGRAMMING WEIGHT ZERO-SETTING FOR LITTLE CHANGES PASSWORD KEY FUNCTIONS OVERVIEW OF SET-UP MENU SET-UP MENU (PROGRAMMING) ALARMS PRINT COMMUNICATION PROTOCOL MODBUS RTU PROTOCOL RS 232 CONNECTION CABLE BETWEEN WT60 AND PC RS 485 CONNECTION AMONG INSTRUMENTS WT

4 RECOMMENDATIONS FOR CORRECT INSTALLATION OF WEIGHT INDICATORS - The entry into the cable board of cells must be independent ( on one side or the other of the board ) and directly connected to the terminal board of the device without breaking by bearing terminal boards or passing through troughs containing other cables. - Use the " RC " filters on the instrument-driven coils of the remote control switches. - Avoid inverter, if inevitable, use filters and separate with sheets. - In case of 230Vac supply, use a 380/230Vac transformer avoiding to use the 380Vac phase and the neutral. - The installer of the board is responsible for securing the electrical safety of the indicators. - It is a good norm to let the indicators always switch on to prevent the formation of condensation. OPERATION Weight transmitter with 4 set-point free settable on full range, 4 output potential free relay contacts (115Vca/30Vdc, 0.5 A). For weights superiour or equal to the values of the set-points the related contacts will be closed. The opening of the contacts for decreasing weight will be executed by considering the histeresys values programmed in the constants. The WT60 is equipped with 3 inputs to perform the following functions: - Weight zero-setting - Print - Gross / Net weight visualization or Peak function CALIBRATION : Instrument calibration can be performed by setting some parameters during the constants programming (THEORETICAL CALIBRATION) or by means of a SAMPLE WEIGHT. SERIAL PORTS: The instrument is equipped with an RS232 serial output (COM 1) and an RS422/485 serial output (COM 2). According to serial ports setting, executable via keyboard, the following connections can be performed: - 24 column printer (net/gross weight, peak value, date, time and instrument identification number can be printed out via external contact). - remote display for weight transmission. - PC / PLC : Communication Protocol for PC, ModBus, ProfiBus (only with converter model Modprofi)

5 TECHNICAL CHARACTERISTICS Power Supply 230 / 115 Vac 50/60 Hz Power consumption 10 VA Insulation Class II Humidity (condensate free) 85 % Operating Temperature -10 C +50 C StorageTemperature -20 C +70 C Display Led Keyboard 5-digit semi-alphanumeric 7 segment led (h 20 mm) 8 Led ( 3 mm) 5 Keys Standard version : Dimensions 144 mm x 72 mm x 120 mm (depth) Drilling template 139 mm x 67 mm Depth 170 mm (terminals boards included) Monting Panel Material of housing Noryl (UL 94 V1) Front Panel Protection IP54 IP67 box version : Dimensions 180 x 180 x 100 mm. Four fixing holes Ø 4 mm (centre distance 163 x 163 mm). Monting Wall Front Panel Protection IP67 Load cells Supply 5 Vdc / 120mA (max 8 cells in parallel 350 ohm) Linearity < 0.01% Full Scale Temperature drift < % Full Scale / C A/D Converter 24 bit Internal divisions (display) +/ Measure range min: - 2 mv to + 2mV ; max 19.5 mv to mv Digital Filter / Conversion rate from 0.2 to 25 Hz ; readings/sec. Decimals / Display increments 0-4 decimals ; x 1 x 2 x 5 x 10 x 20 x 50 x 100 Logic Outputs Logic Inputs N 4 relays (NO contacts) max 115Vac/30Vdc, 0.5 A cad. N 3 optoisolated 12Vdc/24Vdc PNP Serial Ports (n 2) COM1: Rs232c half duplex ; COM2: Rs422/Rs485 half duplex. Max cable lenght 5 m (Rs232c) ; 500 m (Rs422 - Rs485) Serial Protocols ASCII; Modbus ; Profibus (only with converter model Modprofi) Baud rate 1200, 2400, 4800, 9600, 14400, 19200, 28000, 38400, selectable - 2 -

6 ELECTRICAL CONNECTIONS Warning: the following procedures must be executed by skilled workers. All the connections must be executed while the instrument is switched off. Connect the load cells by means a terminal board in a water-proof junction box, by connecting the leads having the same colour; perform the same operation for the shield. By means of a shielded cable with a section not lower than 0,2 mmq connect the terminal board to the WT60. The routing shall be far away from the power cables and possibly protected by a metal pipe. WT60 BASE CONNECT THE SHIELD TO THE GROUND LOAD CELLS: 4-WIRE CONNECTION L N EXCITAT.+ EXCITAT. - SENSE + SIGNAL + SIGNAL - SENSE - 6-WIRE CONNECTION LOAD CELLS COM (1 / 2) ZERO NET-GROSS / PEAK PRINT COMMUN INPUTS COMMON OUTPUTS SET 4 SET 3 SET 2 SET Vca COM CONNECTOR (1 / 2): 1.SHIELD 2.( RX ) RS232 - COM 1 3.( TX ) RS232 - COM 1 4.( TX + ) RS422 - COM 2 5.GND - COM 1 6.( TX - ) RS422 - COM 2 7.( RX - ) RS422 - COM 2 8.( CTS ) RS232 - COM 1 9.( RX + ) RS422 - COM 2 WARNING: The RX - of the RS422 output is connected at PIN 7, while in WT30000-series instruments it was connected at PIN SIGNAL + SIGNAL - EXCITAT. + EXCITAT

7 IP67 BOX VERSION CONNECTOR COM 1 / 2 1.SHIELD 2.( RX ) RS232 - COM 1 3.( TX ) RS232 - COM 1 4.( TX + ) RS422 - COM 2 5.GND - COM 1 6.( TX - ) RS422 - COM 2 7.( RX - ) RS422 - COM 2 8.( CTS ) RS232 - COM 1 9.( RX + ) RS422 - COM COM WARNING: The RX - of the RS422 output is connected at PIN 7, while in WT30000-series instruments it was connected at PIN 1. 4-WIRE CONNECTION LOAD CELLS 1 2 EXCITAT. + EXCITAT SIGNAL+ SIGNAL - CONNECT THE SHIELD TO THE GROUND L N EXCITAT.+ EXCITAT. - SENSE + SIGNAL + SIGNAL- SENSE - 6-WIRE CONNECTION LOAD CELLS ZERO NET- GROSS / PEAK PRINTER COMMUN INPUTS COMMON OUTPUTS SET 4 SET 3 SET 2 SET Vac CHANGING VOLTAGE Remove the board and connect together the welding points market in the diagram using a stiff wire (on welding side, located under the transformer ). 230 Vca 115 Vca JP V. JP V. JP V. JP V. JP V. JP V

8 STARTING UP THE INSTRUMENT Turn on the instrument. Supply the instrument, wait for about 5 minutes so that all components reach a steady temperature. Make sure that the displayed weight is positive and that increases if one subjects the container to a force weight. In case the instrument displays a negative value or no Conn, SEGn InF, no-segn messages, check the load cells connection and the correct load cells installation (loading direction). Check the correct mechanical installation of the container ( the position of tubes, mounting accessories, etc. ). TARE ZERO-SETTING ( ONLY FOR INSTRUMENT ALREADY CALIBRATED IN LABORATORY) Make sure that the container is empty, during the weight displaying phase press the CONST key and the ConSt message will appear for 2 seconds, while this message is displayed press, the message CAL.tE. will appear. Press, the CALIb message will appear, press ENTER and the display will show CAL alternating with the weight reading. Press ZERO to set the tare to zero. To exit, after setting the tare to zero, press ESC for two times to return to the weight displaying phase. After the tare zero-setting, the tare value will be memorized in the ZEro parameter (submenu CAL.tE. ), take note the value (see page 6). In case of tamperings or instrument replacement, if it is not possible to unload the product to repeat the operation, you can write the memorized ZEro value in the tara parameter (submenu CAL.tE. ). ALARM: In case the instrument shows the message, it indicates that the weight is higher than the value programmed in the CAPAC parameter

9 INSTRUMENT CALIBRATED IN LABORATORY In this case the instrument is supplied pre-calibrated; proceed with a calibration check. Set values : CAPAC ( ); SEnSI. ( ); divis ( ) INSTRUMENT CALIBRATION CHECK: Ensure that the container is empty and that the instrument displays zero. Place a significant amount of products in the container (equal to at least 50% of the maximum quantity to be weighed) and ensure that the instrument indicates the correct value. - If there is a significant difference between the displayed value and effective amount ( greater than 1-2% ) check that this is not caused by a mechanical fault and check the electrical connections of the cell and the cell loading position. If the difference is not significant but around 1-2 % proceed with paragraph WEIGHT DISPLAY CORRECTION VIA KEYBOARD. CORRECTING DISPLAYED WEIGHT FROM KEYBOARD If the instrument indicates a weight that is different from actual product weight inside the container, proceed in the following way: During the weight displaying phase press the CONST key, the " ConSt " message will appear, while this message is displayed press FORM, the following appears: CAL.tE., press, the following appears: CALIb, press ENTER and the display will show CAL alternating with the weight reading, press and program the value of weight that is into the container by using and to increase / decrease the value, to change position (next digit). After setting the value and verifying its correctness, confirm pressing the ENTER key, the display will show CALIb alternating with the weight reading, then press ESC for two times to exit and return to the weight displaying phase. After the WEIGHT DISPLAY CORRECTION, the PortA. parameter will change, take note this value (submenu CAL.tE. ). In case of tamperings or instrument replacement, if it is not possible to unload the product or using a sample weight to repeat the operation, you can write the memorized PortA. value in the CAPAC parameter (submenu CAL.tE. )

10 INSTRUMENT THAT HAS NOT YET BEEN CALIBRATED In this case the instrument has been supplied not calibrated; proceed with its CALIBRATION (THEORETICAL or SAMPLE WEIGHT), TARE ZERO-SETTING and CALIBRATION CHECK procedures. CALIBRATION PARAMETERS ( submenu CAL.tE. ) CAPAC ( kg, only whole numbers) : Full scale load cells, it is used for Theoretical Calibration togheter with SEnSI. and divis parameters. tara ( kg, only whole numbers) : Tare ; it is used for setting the tare value when it is not possible to unload the product to execute a TARE ZERO-SETTING. SEnSI. ( mv/v ) : Load cell sensitivity, it is used for Theoretical instrument Calibration togheter with CAPAC and divis parameters. divis (Divisions) : System s resolution. PortA.,( ) only reading parameter ; capacity : only reading parameter; after calibration (theoretical or with sample weight) this parameter shows the value memorized in the CAPAC parameter. It changes after a CORRECTING DISPLAYED WEIGHT VIA KEYBOARD. Take note this value. In case of tamperings or instrument replacement, if it is not possible to unload the product or using a sample weight to repeat the THEORETICAL CALIBRATION, you can write the memorized PortA. value in the CAPAC parameter. ZEro,( ) only reading parameter ; after the tare zero-setting, the tare value will be memorized in this parameter. Take note the value; in case of tamperings or instrument replacement, if it is not possible to unload the product to reset the tare, you can write the memorized ZEro value in the tara parameter

11 THEORETICAL INSTRUMENT CALIBRATION The entry of CAPAC, SEnSI. and divis parameters, enables instrument calibration without the need for a sample weight. Obviously the calibration settings should be tested with a known quantity of product. During the weight visualization, press CONST, the "ConSt" message will appear, while this message is displayed press the key, CAL.tE. message appears, then press ENTER the following appears: CAPAC, press ENTER then set the full scale for the load cells in integral values without decimals. Example: if there a three load cells with a rated capacity of 300 kg, and the required resolution is 0.1 kg, set this parameter to 900. Confirm with ENTER, then press, the following will appear: tara, press and the following will appear: SEnSI, press ENTER and set load cell sensitivity expressed in mv with 4 decimal points. For load cells with sensitivity 2mV/V, set (for example: for 3 load cell with sensitivity mV, mV, mV, set mV). Confirm with ENTER, then press, the following will appear: divis, (resolution: from to 100). Press and then set system resolution from the options available. Each time resolution is modified the zero-setting and full scale in the memory are calculated automatically. Resolutions that are incompatible with calibration parameters or settings in the memory are not accepted. Press ENTER to confirm, then press ESC for two times to return to the weight display. On completion of THEORETICAL CALIBRATION proceed as follows : - RESET THE TARE( see paragraph TARE ZERO-SETTING). - CHECK CALIBRATION (see paragraph INSTRUMENT CALIBRATION CHECK). - if necessary CORRECT WEIGHT VIA KEYBOARD (see paragraph WEIGHT DISPLAY CORRECTION VIA KEYBOARD)

12 CALIBRATION WITH SAMPLE WEIGHT PROCEED TO CALIBRATION WITH SAMPLE WEIGHT ONLY IF YOU DO NOT KNOW THE FULL SCALE AND SENSITIVITY OF LOAD CELLS, or WITH LEVER RATIO SYSTEMS. Press CONST, the " Const " message appears, while this message is displayed press the CAL.tE. message appears, press ENTER, the following appears: key, " CAPAC ", press ENTER and set the value , confirm with ENTER. Then press until the divis message appears, press ENTER and set the resolution. Confirm with ENTER and the divis message appears again. Press ESC and the CAL.tE. message appears, then press, the following appears : CALIb, press ENTER, the message CAL alternated with the weight returns on display. Press ZERO to zero-set the system tare, place a significant amount of products in the container (equal to at least 50% of the maximum quantity to be weighed) checking on display that increase is proportional to the loaded weights, in order to ensure that no mechanic friction is present. Press and enter the sample weight value by using keys and to increase or decrease the value and to move to the next digit. After setting the value and checking that no other factors affect the container, press ENTER to confirm and the CALIb message, alternated with the weight, returns on display. Press ESC for two times to return to the weight displaying

13 SET POINT and HYSTERESIS PROGRAMMING During weight display, press FORM, to display: SEt l (set-point value 1) press ENTER and program set point value 1 by using keys to increase or decrease the value and to move to the next digit.. Press ENTER to confirm, followed by to display: and SEt 2 (set-point value 2) press ENTER and program set point value 2. Press ENTER to confirm, followed by to display: SEt 3 (set-point value 3) press ENTER and program set point value 3. Press ENTER to confirm, followed by to display: SEt 4 (set-point value 4) press ENTER and program set point value 4. Confirm with ENTER, then press ESC to display : IStE. 1 (hysteresis for set-point 1) press ENTER and program the hysteresis for set-point 1, by using keys and to increase or decrease the value and to move to the next digit. The condition of the set-point relay will change for decreasing weight when the weight will be equal to the programmed set-point value minus the one programmed in this constant. Press ENTER to confirm, followed by to display: IStE. 2 (hysteresis for set-point 2) press ENTER and program the hysteresis for set-point 2. Press ENTER to confirm, followed by to display: IStE. 3 (hysteresis for set-point 3) press ENTER and program the hysteresis for set-point 3. Press ENTER to confirm, followed by to display: IStE. 4 (hysteresis for set-point 4) press ENTER and program the hysteresis for set-point 4. Press ENTER to confirm, followed by ESC to return to the weight display

14 WEIGHT ZERO-SETTING FOR LITTLE CHANGES The instrument enables the reset function only if the quantity displayed is lower than the value set in the constant 0 SEt. If an attempt to reset a higher value is made, the message t is displayed and reset is not performed. Zero-setting via keyboard: Press ZERO during the weight display and the instrument displays the message StorE for 3 seconds. To reset the weight, press ENTER to confirm while the message remains on display. Zero-setting via contact: Close the ZERO contact briefly (approx. 0.5 seconds) to reset the weight. NET / GROSS FUNCTION (MANUAL BATCHING) - Press DOSA key or close the NET/GROSS external button to set to zero the instrument and allow to the operator to load additional quantities of product (the letter n will appear on the left hand side of the display). This operation may be carried out several times by the operator according to need. - Hold down DOSA or close the NET/GROSS button for about 3 seconds to return to the gross weight. Microlectra bv. Hermanus Boerhaavestraat ME Oud-Beijerland. Netherlands. Tel 31(0) Fax 31(0) info@microlectra.nl

15 ACCESS PASSWORD ( 6935 ) It is possible to access to the programming and calibration functions by using a password. ENABLE THE PASSWORD: 6935 Press CONST, the "ConSt" message will appear, while this message is displayed press the key, 0000 will appear, enter 6935 (password), by using keys and to increase or decrease the value and to move to the next digit. Then confirm with ENTER, off will appear. Press and enter the numbers corresponding to the following functions (the operator will be able to access to the following functions only by means of the password): 1 = CAL.tE. ; CALlb parameters ( Theoretical Calibration, Tare zero setting, Weight correction, Calibration with sample weight). 2 = Set-up Menu ( test excluded). 3 = Set-Point and Istheresys programming. For example: In order to protect the access to instrument s calibration and programming of set-point, set "00013" or "10030" (it doesn t matter the order in which you set the numbers corresponding to the functions to be blocked). After setting the numbers of the parameters to be blocked, confirm with ENTER to exit and return to the weight display. DISABLE THE PASSWORD: Press CONST, the "ConSt" message will appear, while this message is displayed press the key, 0000 will appears. Enter 6935 by using keys and to increase or decrease the value and to move to the next digit; then confirm with ENTER. Enter 00000, then press ENTER again to disable the password and return to the weight display

16 KEY FUNCTIONS WITHIN MAIN MENU AND SUBMENUS To access the main menu press CONST, the " ConSt " message will appear, while this message is displayed press the key. - set to zero the displayed value during the parameter programming. - exit from submenu item and return to previous item; exit main menu - move to the next digit during the parameter programming - move to next menu item - increase the value of selected parameter - move to previous menu item - decrease value of selected parameter - enter selected menu item - confirm values entered in parameters LED FUNCTIONS: L1 : Status of ZERO input; illuminates when the ZERO input contact is closed. L2 : Status of PRINT input; illuminates when the PRINT input contact is closed. L3 : Status of NET/GROSS input; illuminates when the NET/GROSS input contact is closed. L4 : Status of PEAK input; illuminates when the PEAK input contact is closed. L5 : Status of set-point1 output; illuminates when the set-point1 output is closed. L6 : Status of set-point1 output; illuminates when the set-point2 output is closed. L7 : Status of set-point1 output; illuminates when the set-point3 output is closed. L8 : Status of set-point1 output; illuminates when the set-point4 output is closed

17 OVERVIEW OF SET-UP MENU To access the main menu press CONST, the " ConSt " message will appear, while this message is displayed press the key : Display Functions CAL.tE. THEORETICAL INSTRUMENT CALIBRATION (see page 7 ) CALIb PArAM TARE ZERO-SETTING (see page 4 ) WEIGHT DISPLAY CORRECTION VIA KEYBOARD (see page 5) CALIBRATION WITH SAMPLE WEIGHT (see page 8) Programming of weighing parameters: filter, autozero, threshold for zero-setting, auto zero-tracking (see pages 16) out Set-point and input operating mode (see pages 17, 18). test Input / Output Test. Cell response signal expressed in mv. Internal points (see pages 18, 19) SeriA. Serial output configuration (see pages 19, 20, 21) Submenu PArAM : Display FILtE. Functions Weight filter parameter (from 0 to 9). ( Standard 5 ) 0 = most rapid response, 9 = maximum filter. Md.FLt. Weight acquisition frequency ( selectable from A to F) ( Standard = A ) AUt. 0 Autozero threshold on activation, expressed as a weight value (0 = disabled) 0 SEt Threshold for zero-setting for small variations. t. InS. 0 Zero-tracking time ( 0,1 to 5.0 seconds ) r. InS. 0 Zero-tracking divisions ( 1 to 99 divisions )

18 Submenu out : Display Functions Operating mode for OUTPUTS 1, 2, 3, 4 : SEt l SEt 2 SEt 3 SEt 4 Condition in which set-point 1 is activated. ( Standard GroSS ) net ; GroSS ; PEAK Output 1 normally open or normally closed. ( Standard n.a. ) n.a. ( open ) n.c. ( closed ) Activation of output 1. PoSIt. (for positive weights) ; negat. (for positive or negative weights) PoS. 0 (for positive weights, 0 included) ( Standard NET-GROSS function ) Operating mode for NET-GROSS/PEAK INPUT (input n. 3) : InG. 3 net. By closing the logic input n. 3, the weight will be set to zero, when L3 Led will light up, this operation can be repeated several times.. By keeping closed the logic input n. 3, the gross weight will appear and the L3 Led will light off. PEAK. Permanent closure of logic input 1 enables the PEAK function and illuminates the relative L4 led. Input opening deactivates the function. Submenu test : Display Functions t - In Logic input test t - out Logic output test. M.VoLt Load cell response signal expressed in mv P div. Internal points for single division

19 Submenu SeriA. : Display bau. C1 PEr. C1 bau. C2 Functions COM1-RS232 Baud rate, options available: 1200, 2400, 4800, 9600, 14400, 19200, 28000, 38400, COM1 ( RS232 ) connections: 232 of (RS232 disabled ) 232 PC (PC or PLC Communication Protocol) 232 ri (remote display) 232 rc (HDRIP575C or HDRIP5125C remote displays) 232 Mo (serial communication by means ModBus protocol ) 232 St (printer) bcdca ( function disabled) bcdef ( function disabled) COM2-RS422/485 Baud rate, options available: 1200, 2400, 4800, 9600, 14400, 19200, 28000, 38400, COM2 ( RS422/485 ) connections: 422 of (RS422/485 disabled ) 422 PC (PC or PLC Communication Protocol) PEr. C2 422 ri (remote display) 422 rc (HDRIP575C or HDRIP5125C remote displays) 422 Mo (serial communication by means ModBus protocol ) 422 Pr (serial communication by means ProfiBus protocol only with ModProfi converter) Addr. Serial address or machine identification address (from 1 to 99) Un. - St. Unit of measure for PRINT ( Kg, Gr, t ) A - CAr. number of lines blank from a printout to another (from 0 to 9) Ind.Pr Serial address fro Profibus Protocol

20 SET-UP MENU To exit and return to the previous menu press ESC. To access the main menu press CONST, the " ConSt " message will appear, while this message is displayed press the key : CAL.tE. This section enables Theoretical instrument calibration (see page 6). CALIb This section enables system tare reset, new calibration with a sample weight, or correction of the display if the instrument displays a value other than the actual weight in the container (see page 4, 5 and 8). PArAM Use and to pass from a parameter to another. ENTER to enter parameter. During the parameters programming use: move to the next digit. and to increase/decrease a value. ENTER to confirm the value programmed. FILtE. (Filter to reduce weight oscillations). The higher the value is, the slower is the weight change. The change of the Filter parameter determines the display update frequency (see table below) and then the analog output, relays outputs and the serial communication. Md.FLt. (weight acquisition frequency). It is also possible to change the weight acquisition frequency of the AD7730 converter, the instrument has six different calculation methods ( A, B, C, D, E, F ). By selecting MODE A ( default ) the acquisition frequency is 57 Hz. By selecting from MODE B to F the acquisition frequency changes according to the Filter parameter (see table below)

21 FILTER DISPLAY UPDATE FREQUENCY ( Hz ) MODE FILTER FILTER WEIGHT ACQUISITION FREQUENCY (HZ) = MODO A 0 to ; 1 ; = MODO b to = MODO C 0 ; to ; = MODO d to = MODO E to = MODO F to Aut. 0 ( autozero threshold). On activation of the instrument, if the weight displayed is lower that the set value in this section, the value is reset. 0 - SEt (reset threshold for small variations). During weight display press ZERO or close the reset input to reset the display, only if the quantity displayed is lower than the value set in this constant. t. InS. 0 (zero-tracking time). To enable the zero-tracking time set from 0.1 to 5.0 seconds. When the balance is empty, the zero-tracking device maintains the zero indication within certain limits automatically; it compensates for slow variations of weight. To active the zero-tracking set t InS 0 and r InS 0 parameters. The zero-tracking runs when the weight is different from the zero for a value equal or lower than divisions set in the r InS 0 parameter, for a time higher than that set in the t InS 0 parameter. To deactive this function set at least one of two parameters to zero. r. InS. 0 (zero-tracking divisions). To enable the zero-tracking time set from 1 to 99. out This section enables setting of the input operating mode and condition for activation of the logic output in relation to the programmed set-point. Programming is independent for each of the 4 logic outputs. Use and to pass from a parameter to another. ENTER to enter parameter

22 SEt 1 (SET-POINT 1 operating mode) net GroSS PEAK SET-POINT 1 is activated according the net weight value. SET-POINT 1 is activated according to the gross weight value. SET-POINT 1 is activated according the peak value. Press ENTER to confirm, the following will appear: n.a. n.c. (normally open) output n 1 is activated when the weight is equal to or greater than the value set in SET-POINT 1. (normally closed) output n 1 is activated when the weight is lower than the value set in SET-POINT 1. Press ENTER to confirm, the following will appear: PoSIt. negat. PoS. 0 output 1 is activated for positive weights only. output 1 is activated for positive and negative weights. output 1 is activated for positive weights, 0 included (if SEt 1 = 0 is programmed). To program SEt 2, SEt 3 and SEt 4 proceed to the previous way. InG. 3 (Operating mode for input n. 3) net PEAK By closing the logic input n. 3, the weight will be set to zero, when L3 Led will light up, this operation can be repeated several times.. By keeping closed the logic input n. 3, the gross weight will appear and the L3 Led will light off. Permanent closure of logic input n.3 enables the PEAK function and illuminates the L4 led. Input opening deactivates the function. test Use and to pass from a parameter to another. ENTER to enter parameter and exit

23 t - In (Logic Inputs Test). The status of inputs can be checked by ensuring the changeover from 0 to 1 for the inpu1 when the relative input changes from open to closed; from 0 to 2 for the input 2; from 0 to 3 for the input 3 the relative input changes from open to closed. The zero on the left represents input 1, and the one on the right represents input 3. t - out (Logic Outputs Test). This enables a check on operation of the four outputs. The instrument shows 0000, the zero on the left represents input 1, and the one on the right represents output 4. Press to close the selected output, press to move to the following output; press again to re-open the output. M.VoLt (load cell response signal expressed in mv) Value with three decimal points. Note: At maximum load, this parameter must not exceed the following values: - cell sensitivity 1 mv/v ---> max set value 5 mv. - cell sensitivity 2 mv/v ---> max set value 10 mv. - cell sensitivity 3 mv/v ---> max set value 15 mv. P div. (Internal points for single division). Internal points used for each single division displayed. SeriA. The instrument is equipped with a RS232 serial port (COM 1) and a RS422/RS485 port (COM 2). For all protocols, communication parameters are fixed at 8 data bits,1 stop bit and no parity. Use and to pass from a parameter to another. ENTER to enter parameter. During the parameters programming use: move to the next digit. and to increase/decrease a value. ENTER to confirm the value programmed. bau. C1 ( baud rate COM 1- RS232 ). Select the desired baud rate: 1200, 2400, 4800, 9600, 14400, 19200, 28000, 38400, For PRINTER connection set Baud-rate for COM 1 =

24 PEr. C1 (COM 1 connections RS232) 232oF 232PC 232rI 232rC 232Mo 232St bcdca bcdef RS232 disabled. Bidirectional Protocol, the instrument responds to the request received from the serial line. Data exchange only occurs if the address set from PC corresponds to that of the instrument. continuous transmission. Protocol for connection to remote display. Protocol for connection to HDRIP575C / HDRIP5125C remote displays. Communication Protocol ModBus RTU. Protocol for connection to a 24-column printer. function disabled function disabled bau. C2 ( baud rate COM 2- RS422/485 ). Select the desired baud rate: 1200, 2400, 4800, 9600, 14400, 19200, 28000, 38400, PEr. C2 (COM 2 connections - RS422/485) 422oF 422PC 422rI 232rC 232Mo 422Pr RS disabled Bidirectional Protocol, the instrument responds to the request received from the serial line. Data exchange only occurs if the address set from PC corresponds to that of the instrument. This protocol supports the RS serial communication system designed for connection of several instruments to a master unit. continuous transmission. Protocol for connection to remote display. Protocol for connection to HDRIP575C/ HDRIP5125C remote displays. Communication Protocol ModBus RT. Profibus Protocol (only with converter model Modprofi). Addr. (instrument address). A value from 1 to 99 can be set

25 Un. - St. (unit of measure for print), selectable: Kg, Gr, t. A - CAr. (number of lines blank from a printout to another) A value from 0 to 9 can be set. Ind.Pr Serial address for Profibus protocol. Set a value from 1 to 126. Microlectra bv. Hermanus Boerhaavestraat ME Oud-Beijerland. Netherlands. Tel 31(0) Fax 31(0) info@microlectra.nl

26 ALARMS no.con : It appears when any load cells is connected, or when a excitation core is not connected. SEGn InF : The load cell signal is lower than -20 mv. no-segn : It appears when a signal core is not connected or the signal is higher than 20 mv. Corto : It appears when a short circuit happens on load cell excitation cores. AdC-Er : error on AD7730 converter. : it indicates that the weight is higher than the value programmed in the CAPAC parameter. _ : it indicates that the weight is lower than no.cal : It appears, alternated to the weight, if no calibration has been executed ( CAPAC = 0 ); the instrument disables the serial communication. no.val : it appears during the calibration when the values are incompatible

27 PRINT For PRINTER connection set Baud-rate for COM 1 = EXAMPLES OF PRINT: Weight printout: From the weight visualization close the PRINT contact. WT data stampa ora stampa 12:15 PESO LORDO = 1077 Kg If DOSA key has been pressed or NET input has been closed, the following will appear: WT data stampa ora stampa 12:15 PESO NETTO = 45 Kg PESO LORDO = 1077 Kg If the PEAK input is closed, the following will appear: WT data stampa ora stampa 12:15 PESO LORDO = 345 Kg PICCO = 3309 kg

28 SERIAL PROTOCOL Baud rate: 1200, 2400, 4800, 9600, 14400, 19200, 28000, 38400, ( selectable ) Data length: 8 ( do not modify ) Bit stop: 1 ( do not modify ) Parity: none ( do not modify ) It is possible to connect up to 32 instruments. TO SELECT THE WEIGHT MONODIRECTIONAL TRANSMISSION SET THE PC CONNECTION IN THE SeriA. MENU and ADDRESS ( Addr. ) = 0 TO SELECT THE WEIGHT BIDIRECTIONAL TRANSMISSION SET THE PC CONNECTION IN THE SeriA. MENU and ADDRESS ( Addr. ) = from 1 to 99 MONODIRECTIONAL TRANSMISSION OF THE WEIGHT Used lines = TX, GROUND Program the instrument number ( Addr ) = 0 Readings per second: Baud rate 9600 / 5700, 5 readings/sec. The WT will transmit the following ASCII string: & N x x x x x x L y y y y y y \ ck ck CR in which : & = 1 character of string beginning ( 38 ASCII ) N = 1 c. of net weight identification ( 78 ASCII ) x x x x x x = 6 c. of net weight or Peak value (if present)( ASCII ) L = 1 c. of gross weight identification ( 76 ASCII ) y y y y y y = 6 c. of gross weight ( ASCII ) \ = 1 c. of separation ( 92 ASCII ) ck ck = 2 ASCII checksum characters calculated considering the characters between & and \ excluded. The checksum value is obtained from the calculation of XOR (or exclusive) of the 8-bit ASCII codes of the characters considered. This obtains a character expressed in hexadecimals with two digits that can have the values from 0 to 9 and from A to F. CR = 1 c. of string end ( 13 ASCII ) The weight data can contain possible fixed zeroes. The first character of net / gross weight can get the value (ASCII 45) in case of negative weight

29 BIDIRECTIONAL TRANSMISSION BETWEEN WT60 AND PC It is possible to connect up to 32 instruments. The PC always starts the communication, the instrument WT is enabled to data interconnection only if the PC s address corresponds to the instrument address. Readings per second:: Baud rate 9600, 30 readings/sec. Baud rate 57600, 160 readings/sec. After reception, the WT waits from 0 to 15 ms before sending a reply. 1) SETTING SET-POINTS FROM PC: Warning: If in the divis parameter has been programmed a value different from 1 / 0,1 / 0,01 / 0,001 and the set-point value that you want to programme is not multiple of divis value, the instrument will round to the nearest whole number below. For example: if divis = 2 and you programme 101, the instrument will round to 100. The PC transmits the following ASCII string containing the set-point to be set on the WT: $ a a x x x x x x y ck ck CR in which : $ = 1 character of string beginning ( 36 ASCII ) a a = 2 c. of address ( instrument number ) x x x x x x = 6 c. of setpoints ( ) y = 1 c. of setpoint s number ( see * ) ck ck = 2 c. of check-sum CR = 1 c. of string end ( 13 ASCII ) * ) y = A ( setpoint 1 ) = B ( setpoint 2 ) = C ( setpoint 3 ) = D ( setpoint 4 ) In the case of correct reception the WT replies with the following string: & & a a! \ ck ck CR in which: & & = 2 characters of string beginning ( 38 ASCII ) a a = 2 c. of address ( instrument number )! = 1 c. of OK reception ( 33 ASCII ) \ = 1 c. of separation ( 92 ASCII )

30 ck ck = 2 c. of check-sum CR = 1 c. of string end ( 13 ASCII ) while in the case of incorrect reception it replies with the following string: & & a a? \ ck ck CR in which : & & = 2 characters of string beginning ( 38 ASCII ) a a = 2 c. of address ( instrument number )? = 1 c. of reception error ( 63 ASCII ) \ = 1 c. of separation ( 92 ASCII ) ck ck = 2 c. of check-sum CR = 1 c. of string end ( 13 ASCII ) 2) READING WEIGHT, SET-POINT AND PEAK (IF PRESENT) FROM PC: The PC transmits the following ASCII string containing the item of data to be read: $ a a j ck ck CR in which : $ = 1 character of string beginning ( 36 ASCII ) a a = 2 c. of address ( instrument number ) j = 1 c. of setpoint s number ( see * ) ck ck = 2 c. of check-sum CR = 1 c. of string end ( 13 ASCII ) * ) j = a ( setpoint 1 ) = b ( setpoint 2 ) = c ( setpoint 3 ) = d ( setpoint 4 ) = p ( peak ) = t ( gross weight ) = n ( net weight ) The first character of net / gross weight can get the value (ASCII 45) in case of negative weight. In the case of correct reception the WT replies with the following string: & a a x x x x x x j \ ck ck CR while in the case of incorrect reception it replies with the following string:

31 & & a a? \ ck ck CR while in the event of a peak request, with no peak configured, it responds with: & a a # CR Error messages: In case of weight present in the container is higher than maximum capacity CAPAC, the alarm message will be displayed. The instrument will transmit the following string: & a a s s O-L s t \ ck ck In case of wrong load cells connection, the o-f message will be displayed. The instrument will transmit the following string: & a a s s O-F s t \ ck ck in which : s = 1 c. of separation (32 ASCII space-). 3 ) WEIGHT ZERO-SETTING FROM PC: The PC transmits the following ASCII string containing the zero-set command: $ a a Z E R O ck ck CR In the case of correct reception the WT replies with the following string: & & a a! \ ck ck CR while in the case of incorrect reception it replies with the following string: & & a a? \ ck ck CR In the event of zero-setting higher than the maximum zero-settable value, it replies with the following string: & a a # CR 4 ) TOGGLING NET WEIGHT FROM PC: The PC transmits the following ASCII string containing the net toggle command: $ a a N E T ck ck CR

32 In the case of correct reception the WT replies with the following string: & & a a! \ ck ck CR while in case of a wrong reception it replies with the following string: & & a a? \ ck ck CR 5) TOGGLING GROSS WEIGHT FROM PC: The PC transmits the following ASCII string containing the gross toggle command: $ a a G R O S S ck ck CR In the case of correct reception the WT replies with the following string: & & a a! \ ck ck CR while in the case of incorrect reception it replies with the following string: & & a a? \ ck ck CR 6 ) READING INPUTS STATUS: The PC transmits the following string ASCII containing the command of reading : $ a a I ck ck CR in which : I = 1 c. of serial command identification ( 73 ASCII ) The WT in case of correct reception replies with the following string containing inputs status: & a a I k k k \ ck ck CR in which : I = 1 c. of serial command identification ( 73 ASCII ) k k k = 3 characters of inputs status ( 0 = OPEN ; 1 = CLOSED) the first character on the left refers to the input n. 1 (terminal 9), character n. 2 = input n. 2 (terminal 10), character n. 3 = input n. 3 (terminal 11) while in case of a wrong reception it replies with the following string: & & a a? \ ck ck CR

33 7 ) READING OUTPUT STATUS: The PC transmits the following string ASCII: $ a a W ck ck CR in which : W = 1 c. of serial command identification ( 83 ASCII ) The WT in case of correct reception replies with the following string containing the outputs status: & a a W z z z z \ ck ck CR in which : W = 1 c. of serial command identification ( ( 83 ASCII ) z z z z = 4 c. of outputs status ( 0 = OPEN ; 1 = CLOSED) the character on the left refers to status of output n. 1 (terminal 13) character n. 2 = input n. 2 (terminal 14) character n. 3 = input n. 3 (terminal 15) character n. 4 = input n. 4 (terminal 16) character n. 5 = input n. 5 (terminal 11) while in case of a wrong reception it replies with the following string: & & a a? \ ck ck CR 8 ) FORCING OUTPUTS: The PC transmits the following ASCII string containing the command for forcing the status of outputs. To undo this command use the UNDO FORCING OUTPUTS COMMAND (9) or swtich off the instrument. $ a a U o o o o ck ck CR in which : U = 1 c. of serial command identification o o o o = 4 c. of outputs status ( 0 = OPEN ; 1 = CLOSED) the character on the left refers to status of output n. 1 The WT in case of correct reception replies with the following string: & & a a! \ ck ck CR

34 while in case of a wrong reception it replies with the following string: & & a a? \ ck ck CR 9) UNDO FORCING OUTPUTS COMMAND: The PC transmits the following ASCII string containing the command for undo the outputs forcing: $ a a o u t d e f a u l t ck ck CR in which : o u t d e f a u l t = 10 c. of serial command identification ( 111, 117, 116, 100, 101, 102, 97, 117, 108,116 ASCII ) The WT in case of correct reception replies with the following string: & & a a! \ ck ck CR while in case of a wrong reception it replies with the following string: & & a a? \ ck ck CR 10) READING DECIMAL NUMBER AND UNIT OF MEASURE : The PC transmits the following ASCII string containing the request of decimal number: $ a a D ck ck CR in which : D = character of serial command identification ( 68 ASCII ) The WT in case of correct reception replies with the following string: & a a x y \ ck ck CR in which : x = character of decimal number, from 0 to 3 ( from 48 to 51 ASCII ) y = character of measure unit, from 0 to 2 ( from 48 to 50 ASCII ; 0 = kg,1 = g, 2 = t ) while in case of a wrong reception it replies with the following string: & & a a? \ ck ck CR

35 CHECK-SUM CALCULATION The check-sum is composed of 2 ASCII characters ( ck ck ) obtained using this procedure : - Consider just UNDERLINED characters. - Calculate the OR ESCLUSIVO ( XOR ) of the codes of the ASCII characters : the XOR operation will give as results: 1 when the number of one of the factors is odd, otherwise the result is 0. character cod. ASCII decimal cod. ASCII hexadecim. cod. ASCII binary t XOR = The result of XOR operation is composed of 2 hexadecimal characters ( number from 0 to 9 or letter from A to F ). - The check sum is composed of 2 characters representing the result of the XOR operation (hexadecimal notation - characters " 7 " and " 5 " ). Check sum calculated: $ 01 t 75 <CR> ( requested weight address 1) Microlectra bv. Hermanus Boerhaavestraat ME Oud-Beijerland. Netherlands. Tel 31(0) Fax 31(0) info@microlectra.nl

36 MODBUS PROTOCOL RTU The MODBUS-RTU protocol enables reading and writing of registers present in LAUMAS instruments, based on the standard addressing system provided in the reference guide of Modicon PI-MBUS-300. Pay special attention to the values sent to the instrument: these must remain within the ranges specified in the tables on the following pages (and must guarantee correct instrument operation). Some data will be written directly into a special memory named EEprom, which can be written a limited number of times only (100,000). Therefore avoid writing continuously in these locations. If not otherwise specified, numerical values are expressed as decimal values in the following pages (in case of 0x prefix values are expressed as hexadecimal). DATA FORMAT - 1 start bit; - 8 data bits, least significant bit; - no parity, odd or even parity. - 2 stop bit in case of no parity (n-8-2) - 1 stop bit in case of checking parity (O-8-1, E-8-1)

37 MODBUS SUPPORTED FUNCTIONS Among the commands available in the MODBUS-RTU protocol, only the following are used to manage communication with the instruments. Other commands may not be interpreted correctly and could generate errors or system shut-downs: FUNCTION DESCRIPTION 03 (0x03) READ HOLDING REGISTER 16 (0x10) PRESET MULTIPLE REGISTERS) INSTRUMENT RESPONSE TIMES The length of time that elapses between the end of the QUESTION string to the instrument and the start of the ANSWER string from the instrument varies between 5 msecs and 20 msecs (max). The length of time that must elapse between the end of the ANSWER string from the instrument and the start of the next QUESTION string to the instrument is 0.5 msec (min). In order to take into consideration the total time of a communication (QUESTION + ANSWER), the transmission times for the strings, which must be calculated according to the baud rate used, must be added to these. Example with 19200bit/sec BAUD RATE: a) 8 bytes QUERY (88 bits) = 4,6 msec b) max delay for response = 20 msec c) 8 bytes RESPONSE (88 bits) = 4,6 msec d) time before the next query = 0,5 msec total = 30 ms (33 communications / second) In general, a longer length of time must be considered to correctly handle the query loop. Some systems are very slow at correctly handling communication timing, resulting in a decrease in the number of queries possible in the unit of time. Where present, the DELAY parameter allows the instrument to respond to the system that is questioning it with a certain delay. This directly influences the number of queries possible in the unit of time. - The serial settings cannot be modified via the serial port itself. Operate manually using the instrument menus. - Modifications made will be active after switching off and on again. Modifications such as the delay time ( Delay ) and the instrument s address ( Address ), however, are active immediately

38 MODBUS RTU PROTOCOL for WT60000 BASE For more information see the reference guide of Modicon PI-MBUS-300. MODBUS RTU supported functions are only READ HOLDING REGISTER and PRESET MULTIPLE REGISTER. Maximum number of writing registers : 6. R = READING register W = WRITING register LIST OF HOLDING REGISTERS Address Description R/W Instrument Error R Gross weight H R Gross weight L R Decimal point R Status Register R Net weight H R Net weight L R Decimal Point R Peak H R Peak L R Decimal Point R SetPoint 1 H R/W SetPoint 1 L R/W Decimal Point R SetPoint 2 H R/W SetPoint 2 L R/W Decimal Point R SetPoint 3 H R/W SetPoint 3 L R/W Decimal Point R SetPoint 4 H R/W SetPoint 5 L R/W Decimal Point R INPUTs/OUTPUTs R/W Command Register W

39 ERRORS CODE OF ADDRESS Instrument Error address Conditions Meanings No Error The instrument is working Out of scale The signal of the load cell is higher the maximum value of 19 mv/v overload The weight value is nine divisions higher than capacity ( CAPAC parameter) underload The weight value is lower than The display will show LIST OF BIT OF ADDRESS Status Register When bit is equal to 1 means the following conditions: Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit fixed fixed fixed fixed fixed fixed Negative Gross Sign Negative Net Sign Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Out of Over Under Valid Tare Minimum 1 0 scale load load weight condition weighing fixed centre Minimum weighing = value set into 0 SEt parameter. Tare condition = Net Weight function activated. LIST OF BIT OF ADDRESS Input/Output In In Out Out Out Out In case of register writing, bit from 4 to 15 will be not considered. LIST OF FUNCTION OF ADDRESS Command Register Command Register allows the following commands: Function Command 0007 Net weight 0008 Semiautomatic zero 0009 Gross weight 0010 Restore Check Output as SetPoint 0021 Keyboard lock 0022 Keyboard unlock

40 RS 232 CONNECTION CABLE BETWEEN WT60 AND PC WT60 (COM) PC POLES MALE 9 POLES FEMALE Microlectra bv. Hermanus Boerhaavestraat ME Oud-Beijerland. Netherlands. Tel 31(0) Fax 31(0) info@microlectra.nl

41 RS 485 CONNECTION AMONG INSTRUMENTS WT60 LAST CONNECTION FIRST CONNECTION WT60 - WL60 - WR WT60 - WL60 - WR WT60 - WL60 - WR GND RX+ TX+ TX- RX- GND RX+ TX+ TX- RX- GND RX+ TX+ TX- RX PIN MALE SOLDER CONNECTOR 9-PIN MALE SOLDER CONNECTOR 9-PIN MALE SOLDER CONNECTOR 130 ohm MAX LENGHT 500 METERS 24 VDC + _ Connect the shield to the connector casing TX + TX - Vin RX + RX - CONVERTER CONVLAU 0 TX RX CONNECTOR DB9P female

Installation and User Manual. version 1.00 MODWF 2014/53/UE EN : /30/UE EN55022:2010 EN :2005 EN :2007

Installation and User Manual. version 1.00 MODWF 2014/53/UE EN : /30/UE EN55022:2010 EN :2005 EN :2007 Installation and User Manual version 1.00 MODWF 2014/53/UE EN300 328:2016 2014/30/UE EN55022:2010 EN61000-6-2:2005 EN61000-6-4:2007 SYSTEM IDENTIFICATION Load Cell Systems reserves the right to change

More information

User Manual version 1.04 TLM8 COMMUNICATION PROTOCOLS

User Manual version 1.04 TLM8 COMMUNICATION PROTOCOLS User Manual version 1.04 TLM8 COMMUNICATION PROTOCOLS Load Cell Systems reserves the right to change specifications without notice. 2018 Web: https://loadcellsys.com Email: sales@loadcellsys.com Phone:

More information

Installation and User Manual version 1.04 TLM8 2014/30/UE EN55022:2010 EN :2005 EN :2007 SYSTEM IDENTIFICATION

Installation and User Manual version 1.04 TLM8 2014/30/UE EN55022:2010 EN :2005 EN :2007 SYSTEM IDENTIFICATION Installation and User Manual version 1.04 TLM8 2014/30/UE EN55022:2010 EN61000-6-2:2005 EN61000-6-4:2007 SYSTEM IDENTIFICATION Load Cell Systems reserves the right to change specifications without notice.

More information

ENGLISH ENGLISH ENGLISH ENGLISH

ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH User Manual version 1.03 TLM8 COMMUNICATION PROTOCOLS KEY TO SYMBOLS Below are the symbols used in the manual to draw the reader's attention: Caution! High Voltage. Caution!

More information

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram ATEX/IECEx version (on request) PVC end-fittings for sheath (on request) PROGRAM BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram External 8-relay modules included. ON REQUEST -B -C -S -3-6

More information

ENGLISH ENGLISH ENGLISH ENGLISH

ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH User Manual version 1.04 TLM8 COMMUNICATION PROTOCOLS Protocols for instruments CE-M APPROVED EN45501:2015-2014/31/UE-OIML R76:2006 KEY TO SYMBOLS Below are the symbols

More information

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram PROGRAM BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram External 8-relay modules included W200 W200-C W200-S W200-3 W200-6 W200-14 ON REQUEST W200-MU CERTIFICATIONS OIML R76:2006, class

More information

ENGLISH ENGLISH ENGLISH ENGLISH

ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH User Manual version 1.03 TLB4 COMMUNICATION PROTOCOLS KEY TO SYMBOLS Below are the symbols used in the manual to draw the reader's attention: Caution! High Voltage. Caution!

More information

1.03 TLB ETHERNET TCP/IP 2004/108/EC EN55022 EN EN SYSTEM IDENTIFICATION

1.03 TLB ETHERNET TCP/IP 2004/108/EC EN55022 EN EN SYSTEM IDENTIFICATION Microlectra bv. Hermanus Boerhaavestraat 6. 3261 ME Oud-Beijerland. Netherlands. Tel 31(0)186-616290 Fax 31(0)186-610349 www.microlectra.nl info@microlectra.nl Installation and User Manual version 1.03

More information

T1 4-Channel Protocol Manual

T1 4-Channel Protocol Manual T1 4-Channel Protocol Manual Leerlooierstraat 8 Nr. 2018.12 Rev1 F: +31 76 50 39481 The Netherlands 1/84 http://www.top-sensors.com KEY TO SYMBOLS Below are the symbols used in the manual to draw the reader's

More information

ENGLISH ENGLISH ENGLISH ENGLISH

ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH User Manual version 1.07 OPTIONS for W SERIES weight indicators KEY TO SYMBOLS Below are the symbols used in the manual to draw the reader's attention: Caution! High Voltage.

More information

Protocol Manual. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.

Protocol Manual. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. T1 Protocol Manual The Netherlands 1/75 http://www.top-sensors.com KEY TO SYMBOLS Below are the symbols used in the manual to draw the reader's attention: Caution! High Voltage. Caution! This operation

More information

T1-transmitter. 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN :2005 EN :2007

T1-transmitter. 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN :2005 EN :2007 T1-transmitter 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN61000-6-2 :2005 EN61000-6-4 :2007 The Netherlands 1/57 http://www.top-sensors.com KEY TO SYMBOLS Below are the symbols used

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

Strain Gauge Converter

Strain Gauge Converter EN Z-SG General Description Module Z-SG is a strain gauge signal converter. Measurements taken using the 6-wires or 4-wires technique are available through Modbus-RTU serial protocol or the analog output.

More information

COMMUNICATION PROTOCOLS

COMMUNICATION PROTOCOLS ENGLISH ENGLISH ENGLISH ENGLISH User Manual version 1.07 COMMUNICATION PROTOCOLS for weight indicators SERIES W (programs: BASE LOAD UNLOAD 3/6/14 PRODUCTS) KEY TO SYMBOLS Below are the symbols used in

More information

TLS. Installation and User Manual version mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2004/108/EC EN55022 EN EN

TLS. Installation and User Manual version mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2004/108/EC EN55022 EN EN ENGLISH ENGLISH ENGLISH ENGLISH Installation and User Manual version 1.11 TLS 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2004/108/EC EN55022 EN61000-6-2 EN61000-6-4 SYSTEM IDENTIFICATION KEY TO SYMBOLS Below

More information

T1-transmitter. 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN :2005 EN :2007

T1-transmitter. 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN :2005 EN :2007 T1-transmitter 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN61000-6-2 :2005 EN61000-6-4 :2007 CE- APPROVED EN45501:2015-2014/31/EU-OIML R76:2006 The Netherlands 1/62 http://www.top-sensors.com

More information

IP67 VERSION BOX (on request) 8+3 PG9 cable glands-plugs. 8+3 PVC fittings for sheath

IP67 VERSION BOX (on request) 8+3 PG9 cable glands-plugs. 8+3 PVC fittings for sheath Digital/analog weight transmitter suitable for back panel mounting on Omega/DIN rail or junction box for field mounting (on request box versions). Weighing system with 8 independent reading channels with

More information

T1-CANopen 2014/30/EU EN55022:2010 EN :2005 EN :2007

T1-CANopen 2014/30/EU EN55022:2010 EN :2005 EN :2007 T1-CANopen 2014/30/EU EN55022:2010 EN61000-6-2:2005 EN61000-6-4:2007 The Netherlands 1/55 http://www.top-sensors.com KEY TO SYMBOLS Below are the symbols used in the manual to draw the reader's attention:

More information

T1-Profinet-IO. 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN :2005 EN :2007

T1-Profinet-IO. 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN :2005 EN :2007 T1-Profinet-IO 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN61000-6-2 :2005 EN61000-6-4 :2007 The Netherlands 1/59 http://www.top-sensors.com KEY TO SYMBOLS Below are the symbols used

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

T1 Weight transmitter PROFINET - IO

T1 Weight transmitter PROFINET - IO Installation and User Manual version 1.02 T1 Weight transmitter PROFINET - IO 2004/108/EC EN55022 EN61000-6-2 EN61000-6-4 SYSTEM IDENTIFICATION Top Sensors products are sold by: Zemic Europe B.V. Tel:

More information

TLB4 TLM8. ERDE-Elektronik AB - Spikgatan Vellinge TLM8den.

TLB4 TLM8. ERDE-Elektronik AB - Spikgatan Vellinge TLM8den. Digital/analog weight transmitter suitable for back panel mounting on Omega/DIN rail or junction box for eld mounting (on request box versions). Weighing system with 8 independent reading channels with

More information

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE

More information

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module -wire Bridge Connection Excitation for to 30 Ω Load Cells 00 Volt (3-way) Isolation Excellent Accuracy (0.0%) DIP Switch Configuration Digital Input Tare Calibration RS8 Modbus RTU Superior Flexible Power:

More information

UniPak UP448 Bridge Input Isolating Signal Conditioner

UniPak UP448 Bridge Input Isolating Signal Conditioner 6-wire Bridge Connection Excitation for to 350 Ω Load Cells 500 Volt (3-way) Isolation Excellent Accuracy (0.0%) DIP Switch Configuration Digital Input Tare Calibration RS85 Modbus RTU Superior Flexible

More information

Pen Drive USB Datalogger!

Pen Drive USB Datalogger! SINGLE PHASE POWER METER Isolated V/I converter -RS485 Modbus - Datalogger Single-phase power meter RMS, and Voltage/Current Isolated. Signal Converter 1000 VDC / 600 VAC, 10 A AC/DC, Variable frequency

More information

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

Warning. Warning. Warning. Pay Attention to Static Electricity. Ask professional personnel to debug, detect. and repair controller.

Warning. Warning. Warning. Pay Attention to Static Electricity. Ask professional personnel to debug, detect. and repair controller. Warning Ask professional personnel to debug, detect and repair controller. Warning Warning Please keep good grounding of controller. In electrical connection of controller, please cut off the power supply

More information

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL

More information

Presented By. NicolScales.com Contact Us

Presented By. NicolScales.com Contact Us Presented By Dallas Ft Worth Austin Houston NicolScales.com 800.225.8181 Contact Us Nicol Scales & Measurement is an ISO Accredited Calibration Company that has provided calibration, repair and sales of

More information

DAT 500 Series Digital / Analog Transmitters. Installation & Operating Manual (version 1.3) 9 Richmond St Picton, Ontario, Canada K0K 2T0

DAT 500 Series Digital / Analog Transmitters. Installation & Operating Manual (version 1.3) 9 Richmond St Picton, Ontario, Canada K0K 2T0 Precise Precise DAT 500 Series Digital / Analog Transmitters Installation & perating Manual version 1.3) Industrial Weighing Systems 9 Richmond St Picton, ntario, Canada K0K 2T0 Tel: 613-786-0016 Web:

More information

COMPLETE MANUAL. WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery.

COMPLETE MANUAL. WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery. COMPLETE MANUAL WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery. TI-1200-S without rechargeable battery and with a smaller cabinet. Note: When TI-1200 is shipped as a part of

More information

User Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6. /8 DIN Process Indicators and Controllers C100, C150, C160 and V100

User Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6. /8 DIN Process Indicators and Controllers C100, C150, C160 and V100 User Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6 1 /8 DIN Process Indicators and Controllers C100, C150, C160 and V100 Electrical Safety This equipment complies with the

More information

7561-PSD Manual Portable Battery Powered Indicator

7561-PSD Manual Portable Battery Powered Indicator 7561-PSD Manual Portable Battery Powered Indicator Lebow Products Inc. 1728 Maplelawn Drive P.O. Box 1089 Troy, Michigan 48084-1089 (800) 803-1164 Phone: (248) 643-0220 FAX: (248) 643-0259 Visit our web

More information

USER MANUAL V1.1. Setpoint unit 2022Setp

USER MANUAL V1.1. Setpoint unit 2022Setp USER MANUAL 0.4.005 V. Setpoint unit 0Setp INTRODUCTION 0Setp is a special edition of Nokeval 0 multi-input indicator. It is available in wall-mounted 800 enclosure or in a /8 DIN panel enclosure. Normally

More information

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Iso DIN. User Manual. 1 channel Earth Fault Monitoring Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee

More information

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160 Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2 Level Indicator L150 and L160 Electrical Safety This equipment complies with the requirements of CEI/IEC 61010-1:2001-2 "Safety requirements

More information

PS-IN202 Weighing Indicator User Manual

PS-IN202 Weighing Indicator User Manual PS-IN202 Weighing Indicator User Manual Version 2015.05 Contents FRONT AND REAR VIEW OF THE INDICATOR CHAPTER 1 CONNECTIONS 1.1 WHAT'S IN THE BOX 1.2 CONNECTING TO THE WEIGH PLATFORM 1.3 CONNECTION TO

More information

Gateway 1400 Reference Manual

Gateway 1400 Reference Manual Profibus-DP Gateway 1400 Reference Manual Copyright All Rights Reserved. No part of this document may be copied, reproduced, republished, uploaded, posted, transmitted, distributed, stored in or introduced

More information

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated

More information

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED D-500s Indicator D - 500 LED User Instructions English 8921-004210 Issue September 2010 1 2-2 0 1 0 D 6 0 0 4 6 7 5 Page 2 D-500s Indicator Page 2 Table of Content Section 1: Introduction. 1.1 Introduction

More information

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250 User Guide IM/C250 MOD_3 Modbus (RTU) Communications Option C250 and V250 Electrical Safety This instrument complies with the requirements of CEI/IEC 61010-1:2001-2 "Safety requirements for electrical

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

LVX Control Unit. Features:

LVX Control Unit. Features: Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count

More information

EXCELL PRECISION CO., LTD.

EXCELL PRECISION CO., LTD. Excell Precision Limited 24. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part

More information

APEX Junior Cased Weighing Indicator/Controller

APEX Junior Cased Weighing Indicator/Controller APEX Junior Cased Weighing Indicator/Controller Non-Trade User Manual www.pcm-uk.com APPROVED DISTRIBUTORS OF: Electronic Weighing Services 1 Index Section 1: Setting Up (Terminations and time/date routines)

More information

Characteristics and functioning

Characteristics and functioning Characteristics and functioning 1/1 enod4-t Characteristics and functioning 216702-C_NU-eNod4T-ETH-E-0314 2/2 enod4-t Characteristics and functioning 216702-C_NU-eNod4T-ETH-E-0314 1 ENOD4 PRODUCT RANGE...

More information

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. LT1300 Wall Mount Load Cell Indicator Datasheet English 1.00 Introduction The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

GS125. Contents. Features. Optional. Strain Gauge Input LED Large Display

GS125. Contents. Features. Optional. Strain Gauge Input LED Large Display 1 GS125 Strain Gauge Input LED Large Display This high intensity LED display offers a flexible solution for a variety of highspeed, high accuracy weighing, batching and level measurement operations. Features

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

GS100P. Weighing Controller. Contents. Order Codes

GS100P. Weighing Controller. Contents. Order Codes GS100P Weighing Controller 1 This intelligent weighing controller comes precalibrated to suit either a 4-wire or a 6-wire strain gauge input, and has a number of advanced functions designed specifically

More information

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION UWE-1707 SERIES CONTENTS ELECTRONIC WEIGHING INDICATOR OPERATION MANUAL 1. SPECIFICATIONS PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE SCALE 2. INSTALLATION 3. ROUTINE OPERATION

More information

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series Laboratory Balances Table of Contents Cautionary Notes and Precautions...3 1. Specification... 4 2. Keys and Display Indicators... 6 3. Commands and abbreviations...7 4. Parts Description...8 5. Unpacking

More information

Transmitter WST 3 From prog. name W001A100. Technical Manual

Transmitter WST 3 From prog. name W001A100. Technical Manual GB Transmitter WST 3 From prog. name W001A100 Technical Manual Transmitter WST 3 Contents 1. Introduction Functions... 1-2 Technical data... 1-4 2. Installation General... 2-1 Electrical installation...

More information

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

! User Manual Rev. 1

! User Manual Rev. 1 User Manual Rev. 1 Warnings For safety operation of the weighing indicator, please follow the following warning/ safety instructions: Calibration inspection and maintenance of the indicator are prohibited

More information

Model 815 User s Manual

Model 815 User s Manual Model 815 User s Manual CAUTION Risk of electrical shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. Weigh-Tronix reserves the right to change

More information

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Operating Manual. English. Digital-Analog Converter DACON8-UMB. English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before

More information

Characteristics and functioning

Characteristics and functioning Characteristics and functioning 1/27 enod4-c Characteristics and functioning NU-eNod4C-ETH-E-1014_216706-A 1 ENOD4 PRODUCT RANGE... 4 1.1 General presentation... 4 1.2 Versions and options... 4 1.2.1 Versions...

More information

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice.

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice. Digital Bench Scale Revision 1.2 September 14, 2000 Contents subject to change without notice. Salter Brecknell Weighing Products 1000 Armstrong Drive Fairmont, MN 56031 Tel (800) 637-0529 Tel (507) 238-8702

More information

Multi-Function Smart Indicator User Manual

Multi-Function Smart Indicator User Manual Multi-Function Smart Indicator User Manual EC30006 Content 1 Notice... 2 2 Specification... 2 3 Main parameter... 3 4 How to fix... 3 5 Port... 4 6 On/Off... 4 7 Charging... 4 8 Display... 5 9 Screen keypad...

More information

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website: 805HP Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com TABLE OF CONTENTS 1. Introduction and Product Features 3 2.

More information

SINGLE-CHANNEL PROCESS INDICATOR series 8001

SINGLE-CHANNEL PROCESS INDICATOR series 8001 SINGLE-CHANNEL PROCESS INDICATOR series 8001 Analog Inputs - all inputs available in one unit - Pt100 RTD type DIN 43 760 or GOST 6651-78 (range from 0 to +600 C) - TC type: J - range from 0 to +600 C

More information

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999

More information

SQ405 Controller CAUTION. The caution messages are displayed before procedures which, if not followed, could cause damage to the equipment.

SQ405 Controller CAUTION. The caution messages are displayed before procedures which, if not followed, could cause damage to the equipment. 87-900-112-01 (A) April 18th, 2011 INSTRUCTIONS SQ405 Controller GENERAL INFORMATION This equipment is destined for use by professionals. The user should read this instruction manual and any other additional

More information

I/O SIGNAL CONDITIONER

I/O SIGNAL CONDITIONER Technical Data Sheet No. TD9809M Rev. F Date of Issue: December 9, 2009 OPERATING MANUAL I/O SIGNAL CONDITIONER CAUTION: THIS PRODUCT DOES NOT PROVIDE GALVANIC ISOLATION. DO NOT ATTEMPT USE OF THIS PRODUCT

More information

Microlectra bv. 2-CHANNEL MODULE OF ANALOG INPUTS SM1 TYPE USERS MANUAL

Microlectra bv. 2-CHANNEL MODULE OF ANALOG INPUTS SM1 TYPE USERS MANUAL Microlectra bv. www.microlectra.nl info@microlectra.nl 2-CHANNEL MODULE OF ANALOG INPUTS SM1 TYPE USERS MANUAL 1 CONTENTS 1. APPLICATION...5 2. MODULE SET...6 3. BASIC REQUIREMENTS AND OPERATIONAL SAFETY...6

More information

PC 150. Digital Bench Scale. Operation Manual

PC 150. Digital Bench Scale. Operation Manual PC 150 Digital Bench Scale Operation Manual Revision 1.2 September 14, 2000 1996-2000 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 35 Waltz Drive Wheeling,

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information

UNIVERSAL CURRENT CONVERTER

UNIVERSAL CURRENT CONVERTER UNIVERSAL CURRENT / VOLTAGE CONVERTER AC/DC Current / Voltage Analyzer The is the first CURRENT / VOLTAGE CONVERTER & ANALYZER ALL IN ONE - of the market. It allow you to connect all isolated current sensors.

More information

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

DKM-407 DIN RAIL TYPE NETWORK ANALYZER DKM-407 User Manual DKM-407 DIN RAIL TYPE NETWORK ANALYZER DESCRIPTION The DKM-407 is a DIN rail mounted precision and low cost unit allowing measurement and remote monitoring of AC parameters of a distribution

More information

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website: 805HP Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com TABLE OF CONTENTS 1. Introduction and Product Features 3 2.

More information

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features. Description LAUREL ELECTRONICS, INC. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets Features Frequencies up to 1 MHz Totals stored in non-volatile

More information

TABLE OF CONTENTS. Communication Functions

TABLE OF CONTENTS. Communication Functions TABLE OF CONTENTS Chapter 1: Chapter 2: Chapter 3: Chapter 4: General Features....................................................... 1-1 Functions......................................................

More information

DCS Series. Digital Counting Scale. Setup Manual

DCS Series. Digital Counting Scale. Setup Manual DCS Series Digital Counting Scale Setup Manual Revision 1.1 February 12, 1997 1996-1997 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 975 Deerfield Parkway

More information

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6 Contents: 1. Introduction Page 2 Specifications Page 2 2. Installation Page 3 3. Key Functions Page 4 4. Operations Page 6 Check Weighing Page 6 Accumulation Page 7 Parts Counting Page 7 Print (RS232C)

More information

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

Thermoelectric Cooler Controller TED1000

Thermoelectric Cooler Controller TED1000 Thermoelectric Cooler Controller TED1000 Operating Instructions MANUAL-TED1000-1.0 Aug 2015 Rev.1 2 Contents 1 General... 4 1.1 Warranty and Assistance... 4 1.2 Maintenance... 4 1.3 General Safety Considerations...

More information

SW Version 1.06 A100E INSTRUCTION MANUAL

SW Version 1.06 A100E INSTRUCTION MANUAL INSTRUCTION MANUAL A100E SW Version 1.06 5 4 Changes to Rev 1.6 22/11/00 Golinelli G. Paulitti G. 3 Changes to Rev 1.5 10/04/99 Golinelli G. Paulitti G. 2 Changes to Rev 1.2 (password) 15/06/98 Golinelli

More information

DXp-10 and DXp-15 Weight Transmitter

DXp-10 and DXp-15 Weight Transmitter Precision Force and Weight Measurement Technologies DXp-10 and DXp-15 Weight Transmitter Applica pplications: Inventory Weighing Process Weighing Web Tension Measurement Product Description l Microprocessor

More information

LCM SYSTEMS. TR150 Portable Battery Powered Indicator. Instruction Manual. Software version V2.XX

LCM SYSTEMS. TR150 Portable Battery Powered Indicator. Instruction Manual. Software version V2.XX TR50 Portable Battery Powered Indicator Instruction Manual Software version V2.XX CONTENTS What is TEDS? Basic concept How it works Advantages Introduction User operation Electrical connection information

More information

INSTRUCTION MANUAL FOR GCS-300 COMMUNICATION [OPTION CODE: C5] GCSC3E

INSTRUCTION MANUAL FOR GCS-300 COMMUNICATION [OPTION CODE: C5] GCSC3E INSTRUCTION MANUAL FOR COMMUNICATION [OPTION CODE C5] GCSC3E1 2002.04 To prevent the accidents by mishandling of this controller, please arrange to give this manual into the hands of the operator who actually

More information

USER MANUAL Z-SG / Z-SG-L

USER MANUAL Z-SG / Z-SG-L USER MANUAL Z-SG / Z-SG-L Strain gauge converter with ModbusRTU protocol MI002633 Page 1 Non è stata trovata alcuna voce d'indice. Seneca Z-PC Line modules: Z-SG / Z-SG-L The Z-SG / Z-SG-L modules allows

More information

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit.

More information

MOD. KBC HEAD KONTAX BATCH CONTROLLER

MOD. KBC HEAD KONTAX BATCH CONTROLLER MOD. KBC HEAD KONTAX BATCH CONTROLLER THE INSTRUMENT DESCRIBED IN THIS MANUAL COMPLIES WITH STANDARDS EMC LIKE ESTABLISHED FROM DIRECTIVE THE EEC AND THE 89/336 DIRECTIVE LOW TENSION THE EEC 73/23 2/2/27

More information

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL v 1.0 Thanks for choosing the Intelligent temperature and humidity controller

More information

CHAPTER 1. Introduction Introduction 3

CHAPTER 1. Introduction Introduction 3 Technical & User Manual Weight Indicator: SMIT-3015 Manufactured By: Samyak Instrumentation Pvt.Ltd. F-4, Memnagar Complex, Opp.Petrol Pump, Memnagar Village, Ahmedabad, India-380052. Phone: +91-79-27495500/5600,

More information

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy Avery Weigh-Tronix Technical Specification Description General This specification describes the indicator, capable of stand-alone operation, or of integration into a larger system via serial interface.

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

Trade Approved Version NMI: S520

Trade Approved Version NMI: S520 @Weigh BW/BWS Series Trade Approved Version NMI: S520 Weighing Indicator User s guide UGBW-E1.09 Table of Contents SECTION 1 INTRODUCTION. 1 SECTION 2 SPECIFICATIONS... 2 SECTION 3 INSTALLATION.3 3. 1

More information

DIGITAL PROCESS CONTROLLER

DIGITAL PROCESS CONTROLLER 1 DPC 965 M R1 R2 R3 R4 TX RX PROG [OPERATOR S MANUAL] 2 Contents Section 1 specification.page 4 Section 2 system Programming Page 4 to 11 Section 3 Precautions..Page 11 Section 4 Connection Diagram.Page

More information

Cyfrowy przetwornik wzmacniający dedykowany dla czujników tensometrycznych

Cyfrowy przetwornik wzmacniający dedykowany dla czujników tensometrycznych Cyfrowy przetwornik wzmacniający dedykowany dla czujników tensometrycznych RQ INSTALLATION MANUAL Rev. 0.2 INDEX DEVICE PROPERTIES TECHNICAL PROPERTIES Pag. 2 TECHNICAL PROPERTIES (follow) Pag. 3 SYMBOLS

More information

RTU560 Connections and Settings DIN Rail RTU 560CIG10

RTU560 Connections and Settings DIN Rail RTU 560CIG10 Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail

More information

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement TP32MTT.03 [ GB ] Probes for soil thermal profile measurement [ GB ] [ GB ] Description Temperature measurement at 7 levels (TP32MTT.03) or 6 levels () In accordance with the requirements of the World

More information

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Vgraph Hardware manual ver Code 114VGRAHWE01. Vgraph CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY ENGLISH. HARDWARE MANUAL ver. 1.

Vgraph Hardware manual ver Code 114VGRAHWE01. Vgraph CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY ENGLISH. HARDWARE MANUAL ver. 1. Vgraph CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY ENGLISH HARDWARE MANUAL ver. 1.01 CODE 114VGRAHWE01 page 1 of 22 Important Important Read these instructions carefully before installing and using

More information