SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

Size: px
Start display at page:

Download "SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics"

Transcription

1 SI Overcurrent and Earth Fault Protection Relay for Secondary Distribution Dual & Self Powered Main characteristics The SI is a overcurrent protection relay with self powered and dual powered (self auxiliary) models. The relay is self powered using the operating current through three / (V) or / (.V) standard current transformers fitted on the lines. These transformers are also used to obtain current measurements. Optionally, SI relay can be used with auxiliary power supply (4 Vdc, Vac, 3 Vac, 48 Vdc or 86 Vdc/ac). The equipment can be occasionally supplied by an external battery portable kit (KITOM). The installation and subsequent maintenance of batteries is eliminated. The operating costs of the centre are reduced. In self powered modes, the startup of capacity to trip at low energy levels. the relay from. times of the nominal current in three phases ensures The line opening mechanism is activated either by means of a striker operated by the energy supplied by the relay itself, or by a coil using the TM trip adapter in case it is necessary. There are bistable magnetic indicators which indicate the trip cause, maintaining their position even though the relay loses the supply (flags). Different sizes installation easier. characteristics: Sampling rate (interval): configurable through communications: 6 min onvolatile M memory in order to store up to.4 events and fault report. Withdrawable Vertical ssembly orizontal ssembly Vertical ssembly 4

2 Technical specifications SI Functions diagram SI attery Vdc P* /P Events RT ( ms) Fault report Setting table * /G /G* LP* / /G 86 PL Demand* Leds config. Out config. * 49T* 68* Fast Start up Input config. * Test Hmi LD x 7 keys T sensitive neutral Striker onnections diagram SI LIE L L L STRIKER < 4 V t Measure Power Measure Power Measure Power Measure URRET IPUTS D6 D7 red black RS48 RS3 KITOM D R S D9 4 GD 8 D8 Tx 3 D Rx 7 RTS 9 SI Digital Protection Self Power UX. EXT. POWER /D D3 D4 D D WRIG Ground P to relay ground GD SFETY GROU OUTPUTS SIxxxxxxxxx eutro Phase SIxxxxxxxxx PIKUP Phase PIKUP eutro D D comun D O D3 D4 comun D O

3 onnections diagram SI Striker Withdrawable model E/F O/ T sensitive neutral Potential free TM LIE L L L3 a OIL t Measure Power Measure Power Measure Power Measure URRET IPUTS D6 D7 7 TM RS48 RS3 KITOM D R S D9 4 GD 8 D8 Tx 3 D Rx 7 RTS 9 SI Digital Protection Self Power IPUTS EXT. UX. POWER /D SIxxxxxxxxx PIKUP PIKUP eutro Phase V D3 D4 D D D D6 D7 8 WRIG Ground P to relay ground GD SFETY GROU OUTPUTS SIxxxxxxxxx eutro Phase SIxxxxxxxxx PIKUP eutro PIKUP Phase D D comun D O D3 D4 comun D O 6

4 Technical specifications SI Technical parameters SI Function P_ Function P_ (*) Function /G_ Function /G_ (*) Function /P Operating range:. to 3 x In (step. x In) Operating time:. to 3 s (step. s) ctivation level % Deactivation level 9% Timing accuracy:± 3 ms or ±.% (greater of Operating range:. to 3 x In (step. x In) Operating time:. to 3 s (step. s) ctivation level % Deactivation level 9% Timing accuracy:± 3 ms or :±.% (greater of Operating range:. to 7 x In (step. x In) urves: IE 6 SI curves Operating time: inverse curve, very inverse curve, extremely inverse curve. Defined time:. to 3 s (step. s) Dial:. to. (step.) urve, activation level % urve, deactivation level % Defined time, activation level % Defined time, deactivation level 9% Timing accuracy:± % or ±3 ms (greater of Operating range:. to 7 x In (step. x In) urves: IE 6 SI curves Operating time: inverse curve, very inverse curve, extremely inverse curve. Defined time:, to 3 s (step. s) Dial:. to. (step.) Function 68 (*) Function 49T (*) Programmable logic control (PL) Function 86 Fault reports Trip output vailable through configurable inputs and outputs thanks to programmable logic harging time s OR4, OR4, OR4_LTH, OR4_LTH, OR4_ PULSES, D4, D4, D4_PULSES, OR_ TIMER_UP, OR_TIMER_UP, D_TIMER_UP, D_TIMER_UP, OR_PULSE, OR_PULSE, D_PULSE, D_PULSE llows to latch (lock out) the contact configured like trip due to programmable logic (PL). fault reports, 6 events in each For Striker: 4 Vdc3 mj For coil (optionally with TM adapter): Vac 8 3 Vdc 8 Resistive charge (cos = ) Signalling outputs (*) Up to 3 configurable outputs Signalling inputs (*) configurable inputs /6Hz RMS Sampling: 6 samples/cycle urrent measure ccuracy of % on a band of ±% over the nominal current and 4% over the rest of the range. RS3 port: Modbus RTU ommunication RS48 port: Modbus RTU (*) uxiliary supply (*) 3 Vac, ± % / Vac, ± % / 4 Vdc ± % / 48Vdc± % / 86 Vdcac± % attery supply Selfpower from current With adapter (Kitcom) port D9 One phase selfpower level: I >, x In Operating temperature: 4 to 7º Environment Storage temperature: 4 to 8 º Humidity: 9% Transformers Power supply and measurement T / or / features Metallic box Panel Mounting /3 Rack 4 U (mechanics type, D, E, F and G).6 Rack 4 U (mechanics type and ) IP4 Demand of current with the following characteristics: Function //G urve, activation level % urve, deactivation level % Defined time, activation level % Defined time, deactivation level 9% Demand of current communications: 6 min Date/Time IMX (in interval) IMX (actual) I I I I Timing accuracy: ±% or± 3 ms (greater of (*) Optional depending on the model 7

5 Dimensions and cutout SI Vertical assembly, D 9. Withwadrable Vertical assembly ompact size F Vertical assembly ompact size E, G Horizontal assembly ,

6 Selection & Ordering data SI SI PROTETIO FUTIOS P /P /G //G 86 PL 6 PHSE MESUREMET In = ; (, 3, ) In = ; (,, ) EUTRL MESUREMET In = ; (, 3, ) In = ; (,, ) In =, ; (, 3, ) In =, ; (, 6, ) ET FREQUEY Hz 6 Hz 3 4 D E F D D E F G POWER SUPPLY Self powered Self powered 3 Vac (Dual) Self powered Vac (Dual) Self powered 4 Vdc (Dual) Self powered 48 Vdc (Dual) Self powered 86 Vacdc (Dual) Self powered report attery Self powered 3 Vac (Dual) report attery Self powered Vac (Dual) report attery Self powered 4 Vdc (Dual) report attery Self powered 48 Vdc (Dual) report attery Self powered 86 Vacdc (Dual) report attery DDITIOL FUTIOS Striker Striker and with external trip (49T) oil oil and with external trip (49T) Striker and 3 Vac adapted external trip OMMUITIOS Local Modus port (RS 3) Remote Modus port (RS48) IPUTSOUTPUTS Outputs to signalling Outputs inputs 3 Outputs to signalling MEMORY onvolatile RM memory onvolatile RM memory Fast startup LGUGE English, Spanish and German English, Spanish and Turkish English, Spanish and French English, Spanish and Russian MEHIS Vertical, withdrawable with 3 magnetic Flags Horizontal assembly with magnetic Flag Horizontal assembly with 3 magnetic Flag Vertical assembly with magnetic Flag Vertical, ompact Size with 3 magnetic Flag Vertical, ompact Size, 3 Flags, acklight LD, withdrawable Vertical, ompact Size, Flag, acklight LD DDITIOL FUTIOS P_ /G_ 3 Setting groups LP 4 Setting groups Example of ordering code: SI 6 D SI 6 D ote: ccessories, page 66. 9

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics SIA-C Overcurrent and Earth Fault Protection Relay for Secondary Distribution Dual & Self Powered Main characteristics The SIA-C is a overcurrent protection relay with self powered and dual powered (self

More information

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics SIA-B Overcurrent & Earth Fault Protection Relay for Secondary Distribution Dual & Self Powered / Standard CTs Main characteristics The SIA-B is an protection relay with self powered and dual powered (Self-powering

More information

SIL-A. Overcurrent and Earth Fault Relay for Primary and Secondary Distribution. Main characteristics

SIL-A. Overcurrent and Earth Fault Relay for Primary and Secondary Distribution. Main characteristics SIL-A Overcurrent and Earth Fault Relay for Primary and Secondary Distribution Main characteristics The SIL-A is an overcurrent and earth fault protection relay for primary and secondary distribution with

More information

Protection relay for secondary distribution

Protection relay for secondary distribution Protection relay for secondary distribution Dual and Self powered Signalling with flag indicators High electromagnetic compatibility Events recorder and specific test menu Protection relay for secondary

More information

SIA/SIL. Secondary and Primary Distribution Protection Relays. Specialized in self powered relays IEC 61850

SIA/SIL. Secondary and Primary Distribution Protection Relays. Specialized in self powered relays IEC 61850 Specialized in self powered relays SI/SIL Secondary and Primary Distribution Protection Relays Dual & Self Powered Relays Overcurrent & Earth Fault Protection Relays Feeder Protection Relays IEC 680 Introduction

More information

INSTALLATION & COMMISIONING GUIDE

INSTALLATION & COMMISIONING GUIDE SIA C Self Power O/C & E/F Protection Relay INSTALLATION & COMMISIONING GUIDE www.fanox.com SIAC11500032AG_Rev. 12 1 / 32 1. RECEPTION & INSTALLATION... 3 1.1. Relay unpacking... 3 1.2. Relay verification...

More information

SIA/SIL. Secondary and Primary Distribution Protection Relays. Specialized in self powered relays IEC 61850

SIA/SIL. Secondary and Primary Distribution Protection Relays. Specialized in self powered relays IEC 61850 Specialized in self powered relays SIA/SIL Secondary and Primary Distribution Protection Relays Dual & Self Powered Relays Overcurrent & Earth Fault Protection Relays Feeder Protection Relays IEC 68 Introduction

More information

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100% Operating range: 0.10 to 30 xin (step 0.01) 50P(2) Activation level 100% Deactivation level 95% Timer accuracy: 30 ms Operating range: 0.10 to 30 xin (step 0.01) 50N/G(2) Activation level 100% Deactivation

More information

SIA C. Self-powered overcurrent relay USER MANUAL

SIA C. Self-powered overcurrent relay USER MANUAL SIA C Self-powered overcurrent relay USER MANUAL 1. RECEPTION, HANDLING, INSTALLATION... 9 1.1. Unpacking... 9 1.2. Reception of relays... 9 1.3. Handling electronic equipment... 9 1.4. Installation, commissioning

More information

SIA B Self and Dual powered Overcurrent & Earth Fault Protection Relay USER S MANUAL L

SIA B Self and Dual powered Overcurrent & Earth Fault Protection Relay USER S MANUAL L SIA B Self and Dual powered Overcurrent & Earth Fault Protection Relay USER S MANUAL L 1. REEPTION, HANDLING & INSTALLATION... 5 1.1. Unpacking... 5 1.2. Reception of relays... 5 1.3. Handling electronic

More information

ISO 9001:2000 SIL A. Overcurrent and Earth fault relay INSTALLATION GUIDE. Guia_SIL-A_Rev / 48

ISO 9001:2000 SIL A. Overcurrent and Earth fault relay INSTALLATION GUIDE.   Guia_SIL-A_Rev / 48 ISO 9001:2000 SIL A Overcurrent and Earth fault relay INSTALLATION GUIDE www.fanox.com Guia_SIL-A_Rev. 01 1 / 48 1.USER INTERFAE... 4 1.1. onfigurable LEDs... 4 1.2. Local communication port. RS232...

More information

SIL. Protection relays for primary and secondary distribution

SIL. Protection relays for primary and secondary distribution SIL Protection relays for primary and secondary distribution Reduced size and light weight Two protocols simultaneously: MODUS & IEC 60870-5-103 With auto-reclosing, trip circuit supervision and cold load

More information

Index POWER T&D. SIA-B (Dual & Self powered) OC&EF Protection for Secondary Distribution with specific transformers... 20

Index POWER T&D. SIA-B (Dual & Self powered) OC&EF Protection for Secondary Distribution with specific transformers... 20 POWER T&D Index What is SELF-POWER?... 6 Why is Fanox the world s leading manufacturer of SELF-POWERED Relays?... 9 Evolution of RMU s Protection Relays.... 1 Protection functions, common features and

More information

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network SIL-G Feeder & Generator Protection Relay RC FLSH Main characteristics The SIL-G is a relay for primary distribution which can protect a feeder by means of current and voltage functions. It is also provided

More information

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays PROTECTION MiCOM P124 Self and Dual Powered Overcurrent Relays MiCOM P124 are numerical relays designed to offer complete overcurrent protection without requiring any external auxiliary supply. They can

More information

GENERAL CATALOGUE. Equipments. Devices. fanox.com

GENERAL CATALOGUE. Equipments. Devices. fanox.com GENERAL CATALOGUE SELF-POWERED s Equipments Devices fanox.com years of protection Fanox designs and manufactures electronic protection relays for Low and Medium Voltage. Since it was founded in 1992, the

More information

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays 01 Self and Dual Powered Overcurrent Relays are numerical relays designed to offer complete overcurrent protection without requiring any external auxiliary supply. They can be applied to a wide variety

More information

ISO 9001:2000 SIL A. Overcurrent and Earth-Fault relay USER S MANUAL SER S MANUAL

ISO 9001:2000 SIL A. Overcurrent and Earth-Fault relay USER S MANUAL SER S MANUAL SIL A Overcurrent and Earth-Fault relay USER S MANUAL SER S MANUAL 1. RECEPTION, HANDLING, INSTALLATION... 1 1.1. Unpacking... 1 1.2. Reception of relays... 1 1.3. Handling electronic equipment... 1 1.4.

More information

Protection Relays PHASE & RESIDUAL OVERCURRENT

Protection Relays PHASE & RESIDUAL OVERCURRENT Protection Relays PHASE & RESIDUAL OVERCURRENT Application The relay type NA016 can be used in radial networks as feeder or power transformer protection. In solidly grounded systems the residual overcurrent

More information

F650 Firmware Release Notes / History (Rev 10)

F650 Firmware Release Notes / History (Rev 10) 1.00 2.00 First version of the product (Basic Model F1G0) Full protection scheme F650BABF1G0HI August 30 th 2002 1.11 2.00 New model F2G0 (inputs and outputs board type 2) F650BABF2G0HI October 14 th 2002

More information

BE1-50/51M TIME OVERCURRENT RELAY ADVANTAGES

BE1-50/51M TIME OVERCURRENT RELAY ADVANTAGES BE1-50/51M TIME OVERCURRENT RELAY The BE1-50/51M Time Overcurrent Relay provides economical overload and fault protection for generators, transformers, lines and motors. ADVANTAGES Self powered from 50/60Hz

More information

CURRENT PROTECTION RELAY SMPR-1

CURRENT PROTECTION RELAY SMPR-1 CURRENT PROTECTION RELAY SMPR-1 1.- ORION ITALIA SERIES MODBUS PROTOCOL. The ORION ITALIA SERIES implement a subset of the AEG Modicon Modbus serial communication standard. Many devices support this protocol

More information

MiCOM P111. Three phase and earth fault overcurrent relays

MiCOM P111. Three phase and earth fault overcurrent relays Three phase and earth fault overcurrent relays The relays are suitable for all the application where overcurrent and/or earth-fault protection are required. Thanks to its favorable price vs technical features

More information

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

ENhanced TEChnology.  Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver. ENhanced TEChnology www.entecene.co.kr Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Ver. 081226 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser

More information

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data SYMAP R Plug in Variants FI, MI, 87M, TI Technical data 1 Product overview SYMAP R (Retrofit) is a digital protection relay for use in medium and high-voltage power systems. Because of its integrated protection

More information

VIP 40/45 VIP 400/410

VIP 40/45 VIP 400/410 40/45 400/410 Selection guide 01 PM100573 40/45 PM100576 400/410 self-powered integrated protection relay Optimised performance for transformer, incomer, feeder and bus riser protection Complete engineered

More information

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators. SR489 Generator Management Relay Economical protection, metering, and monitoring functions for small and medium sized generators. 1 Product Highlights Inputs / Outputs Generator Protection Power Metering

More information

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System Advanced Protection Relay Test Set and Measurement System Multi-tasking equipment designed for testing protection relays, energy meters, transducers Particularly designed to test RTU (remote terminal unit)

More information

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3 www.entecene.co.kr Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser encapsulated with

More information

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

ENhanced TEChnology.   Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1 ENhanced TEChnology www.entecene.co.kr Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser encapsulated

More information

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box INTRODUCTION The PL-50 MO units are available in the next mechanical version: The PL-50 MO and PM-250 families represent the different solutions that Team Arteche offers for motor protection. Both families

More information

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V Version: 1 Issued: March 2014 Owner: Electrical Networks Asset

More information

Record Plus. Trip Units. Intro. Thermal Magnetic Trip Units. FD frame B.2

Record Plus. Trip Units. Intro. Thermal Magnetic Trip Units. FD frame B.2 Thermal Magnetic frame Record Plus circuit breakers are designed to isolate and switch low voltage distribution circuits and to protect the conductors, equipment and devices included in these circuits.

More information

Temperature/Process Controllers Manual

Temperature/Process Controllers Manual 3200 SERIES Temperature/Process Controllers Manual The innovative range of 3200 controllers offer precision control of temperature and other process variables together with a host of advanced features

More information

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead solutions Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead switching products Brochure Your outdoor overhead distribution

More information

MP7. Uninterruptible Power Supply

MP7. Uninterruptible Power Supply Uninterruptible Power Supply PRODUCT SPECIFICATIONS Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

IEC Power Control Contactors and Contactor Assemblies

IEC Power Control Contactors and Contactor Assemblies IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,

More information

MiCOM P123R. Overcurrent Relays P123R/EN AD/A11. Upgrade Documentation

MiCOM P123R. Overcurrent Relays P123R/EN AD/A11. Upgrade Documentation MiCOM P123R Overcurrent Relays Upgrade Documentation MiCOM P123R Page 1/14 CONTENTS MiCOM P123R ADDENDUM: MiCOM P12X UPDATE DOCUMENTATION 3 P12X/EN IT/EB6: INTRODUCTION 4 P12x/EN TD/Eb6: TECHNICAL DATA

More information

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution UR An integrated feeder protection and metering solution Power to Manage your Facility Connectivity ModBus RTU MMS/UCA2 TM Protocols SI Compatibility Flexibility FlexCurves FlexLogic The first Relay designed

More information

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

Product Sheet ECO. Types ECG, AMF Technical data.  product sheet eco ecg-amf - technical data gb v1.0.docx ECO Types ECG, AMF Technical data Product overview ECO ECG and ECO AMF are microprocessor controlled devices for use in low voltage single genset applications for standby power generation. The front-side

More information

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test: Advanced Protection Relay Test Set and Measurement System Multi-tasking equipment designed for testing protection relays, energy meters, transducers Particularly designed to test RTU (remote terminal unit)

More information

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter. www.sordselectric.com MA7200 Sensorless Vector AC Inverter Features and Benefits Sensorless Vector The MA7200 has precise speed and torque control for the most demanding system performance and simple set-up

More information

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering.

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering. MIN II Key Benefits Reduce troubleshooting and maintenance cost - event recording, and analogy/digital oscillography Design flexibility - Easy to use programming logic Access to information - Modbus RTU

More information

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7 Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND OleumTechTM TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND MUST BE FAMILIAR WITH LEVEL 1 TRAINING MATERIALS BEFORE MOVING FORWARD Doc ID# 80-6010-001b TABLE OF CONTENTS 1. WHAT IS NEW WRITE IMPORT

More information

OVERCURRENT / GROUND FAULT PROTECTION RELAY MPRB GF. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

OVERCURRENT / GROUND FAULT PROTECTION RELAY MPRB GF. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A. OVERCURRENT / GROUND FAULT PROTECTION RELAY MPRB-99-1.0-GF (Code 512 191 ) INSTRUCTION MANUAL ( M 981 222 / 00 A ) (c) CIRCUTOR S.A. --- OVERCURRENT / GROUND FAULT PROTECTION RELAY MPRB-99-1.0-GF --- Page

More information

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL BE1-851E ENHANCED OVERCURRENT PROTECTION SYSTEM DEVICE FUNCTIONS 43 50 51 62 The BE1-851E is an enhanced overcurrent protection system based on the design of the BE1-851, a multifunction, numeric relay

More information

Chapter. Specifications - Terminal Bases and Power Supplies. In This Chapter:

Chapter. Specifications - Terminal Bases and Power Supplies. In This Chapter: Specifications - hapter Terminal ases and Power Supplies In This hapter: TK-0(-) I/O Terminal ase... TK-(-) I/O Terminal ase... TK-0, TK-0 Power Supply... alculating the Power udget... Managing the Power

More information

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik PT2060/ System Interface Module ProvibTech s PT2060/ module is a communication and system interface module. This module is used to: module. The two phase reference channels can be used to provide phase

More information

User Manual. cmt-iv5 Startup Guide

User Manual. cmt-iv5 Startup Guide User Manual cmt-iv5 Startup Guide v 2.2 JAN 8, 2016 Table of Contents Chapter1. Overview... 1 1.1. Specification... 1 1.2. Dimensions... 2 1.3. Ethernet port... 3 1.4. CR1225 battery... 3 1.5. Power connection...

More information

ATS Automatic transfer switches Advanced version

ATS Automatic transfer switches Advanced version 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 ATS CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 5. CONFORMITY 4 6. EQUIPMENTS

More information

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin Overcurrent and Arc Protection by Reyrolle Alexander Erokhin VAR Partner Day September 20-21, 21, 2017 I Berlin Reyrolle Product Range by SIEMENS Challenges We Meet for our Customers Easy-to-use protection

More information

MOUNTING BASE AQB-A402 PLAN VIEW OF MOUNTING BLOCK & CIRCUIT BREAKER AQB-A802 CIRCUIT BREAKER MOUNTING BLOCK 2.50 MOTOR OPERATOR 25.

MOUNTING BASE AQB-A402 PLAN VIEW OF MOUNTING BLOCK & CIRCUIT BREAKER AQB-A802 CIRCUIT BREAKER MOUNTING BLOCK 2.50 MOTOR OPERATOR 25. Weights & Dimensions 4 1/8 4 5/16 4 1/8 4 5/16 Weights & Dimensions 5 1/16 6 1/2 15 1/2 17 15/16 A C A C 6 3/16 MOUNTING ASE MOUNTING ASE 5 1/16 6 3/16 MOUNTING ASE DIMENSIONS DESCRIPTION A C SINGLE ASE,

More information

DTM Distributed Transmitter Monitor

DTM Distributed Transmitter Monitor Distributed Transmitter Monitor 96 Communication Module The 96 functions as an RS232 to RS485 convertor and / or enables (32) modules to be networked together via Modbus. Combined with the -CFG configuration

More information

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control Description Features Application The Powermite 599 MT Series SAS Electronic Valve Actuator requires a 24 Vac

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

Record Plus. Trip Units. Intro. Thermal Magnetic Trip Units. FE frame B.6

Record Plus. Trip Units. Intro. Thermal Magnetic Trip Units. FE frame B.6 Thermal Magnetic The breakers are availble as a complete entity or in kit form where a reaker rame and an interchangaeble trip unit are the basic components. The interchangeability feature covers the electromechanical

More information

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters Applications Telecom IT Industrial Safety in compliance with IEC60950:1999, 3 rd edition; EN60950:2000; UL60950, 3 rd edition; CSA Standard C22.2 No.60950-00, 3 rd edition Features New, compact design:

More information

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

METERING INSTRUMENTS AND CURRENT TRANSFORMERS Energy Meters p16-1 Data Concentrators p16-3 Digital Measuring Instruments p16-4 Expansion Modules and Accessories p16-15 Current Transformers p16-19 Software and Applications p16-22 Systems Management

More information

Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement

Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement 8 DN Multisignal Panel Meter Economical Panel Meter for Process, Temperature and Electrical Measurement DP20 TM DP20 meter shown smaller than actual size. OME s new multisignal panel meter delivers high-performance

More information

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications.

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications. PRODUCT DESCRIPTION INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications. DINAMAP MPS Select Portable Monitor General

More information

NPW800R RETROFITTING. Power and Volatge Protection Relay

NPW800R RETROFITTING. Power and Volatge Protection Relay RETROFITTING Power and Volatge Protection Relay NPW800R (R3 case) is dedicated to the refurbishment of CEE WTG 7000 relays (R3 case) providing the measurement of apparent (S), active (P) and reactive (Q)

More information

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION The digital galvanic longitudinal differential protection of type DGSZV-EP is part of device family named EuroProt. This short description

More information

Easy To Use OEMS Take Note

Easy To Use OEMS Take Note MA7200 Features Sensorless Vector Precise speed and torque control for the most demanding system performance. Simple set-up through autotuning function. The MA7200 can be operated in sensorless vector

More information

Request publication Request publication DNP 3.0 INSTRUCTION MANUAL. Request publication

Request publication Request publication DNP 3.0 INSTRUCTION MANUAL. Request publication BE1-851 OVERCURRENT PROTECTION SYSTEM The BE1-851 is a multifunction, numeric relay that provides three phase, ground, and negative sequence overcurrent protection with four shot recloser, breaker failure,

More information

PROTECT Electronics Co. Ltd

PROTECT Electronics Co. Ltd Independent static overcurrent relay Document ID: 24-13-15848-00 Budapest, 2006 User s manual version information Version Datum Modification Compiled by.00 May 1995 First Hungarian version Póka.01 June

More information

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North

More information

BE1-51 BE1-51/27C BE1-51/27R TIME OVERCURRENT RELAY

BE1-51 BE1-51/27C BE1-51/27R TIME OVERCURRENT RELAY BE1-51 BE1-51/27C BE1-51/27R TIME OVERCURRENT RELAY The BE1-51 Series of Time Overcurrent Relays is microprocessor-based to provide versatile overload and fault protection on 50Hz or 60Hz systems. ADVANTAGES

More information

tec P - CK010 Self-Powered

tec P - CK010 Self-Powered V 4.F tec P - CK010 Self-Powered Protection unit Product detail & Installation Instructions Outec Controls Pretoria South Africa 1 Attention In order to use the unit safely, correctly and effectively,

More information

SACE Emax 2 Specification guide

SACE Emax 2 Specification guide SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or

More information

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Iso DIN. User Manual. 1 channel Earth Fault Monitoring Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee

More information

ZENSOL CIRCUIT BREAKER PERFORMANCE ANALYZER

ZENSOL CIRCUIT BREAKER PERFORMANCE ANALYZER ZENSOL AUTOMATION INC. COMPUTERIZED TEST EQUIPMENT ZENSOL CIRCUIT BREAKER PERFORMANCE ANALYZER CBA-32P Micro CBA MANUAL 1W E OPERATOR S GUIDE Version 1.70 January 2001 www.zensol.com Man-1we.doc Rév 5

More information

ProVU 4 Advanced Temperature & Process Controller

ProVU 4 Advanced Temperature & Process Controller ProVU 4 Advanced Temperature & Process Controller 1/4 DIN Format Graphical / text LCD Display (red/green) Profiling option Datalogging option (data, alarms & events) 5 language (English, French, German,

More information

PowerCore Model TEC-10 Installation Manual

PowerCore Model TEC-10 Installation Manual PowerCore Model TEC-10 Installation Manual Products covered in this document comply with European Council electromagnetic compatibility directive 2014/30/EU and electrical safety directive 2014/35/EU.

More information

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description ProVU 4 Advanced Temperature Controller ¼ DIN Format Graphical / text LCD Display (red/green) Profiling option Datalogging option (data, alarms & events) 5 language (English, French, German, Italian, Spanish)

More information

SSW06. Soft Starters.

SSW06. Soft Starters. The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which provide visibility and make programming easier. Integral bypass contacts eliminate heat dissipation

More information

PQM4000 and PQM4000RGW

PQM4000 and PQM4000RGW PQM4000 and PQM4000RGW Class A DIN 192x144 power quality analyzer Class A certified for CTs or current clamps (PQM4000) with Rogowski coils (PQM4000RGW) PQM4000 Class A DIN 192x144 power quality analyzer

More information

iswitch imotor Compact QR

iswitch imotor Compact QR PRODUCT DATA SHEET iswitch imotor Compact QR Features: Compact design Fit for purpose Suitable for 2 feeder switches Quick Release for manual operation High operation torque Operation monitoring (max.

More information

Modbus Server SIEMENS Algorex (printer port)

Modbus Server SIEMENS Algorex (printer port) IntesisBox Server SIEMENS (printer port) Gateway for the integration of Siemens fire detection panels into enabled control systems. Monitor your fire panels remoy from your Control Center using any commercial

More information

PM800 series. Applications

PM800 series. Applications Functions and characteristics PE86134 The PowerLogic meters offers many high-performance capabilities needed to meter and monitor an electrical installation in a compact 96 x 96 mm unit. All models include

More information

FAULT INDICATOR Type EFI/P

FAULT INDICATOR Type EFI/P APPLICATIONS Detect earth faults in medium voltage net Highlights Earth fault passage indicator combined Automatic and manual reset Front push button for test and reset Selectable earth fault trip currents

More information

Remote communication options include IEC Ethernet communications or Modbus (RS485).

Remote communication options include IEC Ethernet communications or Modbus (RS485). 2019 The MELPRO D series relay is suitable for feeder protection, motor protection and transformer protection applications. The relay offers multiple step time grading for over-current protection co-ordination.

More information

Multifunctional time delay relay MFT U31S, MFT U41SE

Multifunctional time delay relay MFT U31S, MFT U41SE 8 Functions, 8 time ranges Multivoltage: 24 Vac / dc 110... 240 Vac 2 output contacts MFT U31S Functions E Delay on E Delay on - version with control contact as opening contact A Delay off without auxiliary

More information

EngyVolt RV12 and RV15

EngyVolt RV12 and RV15 Technical Information EngyVolt RV12 and RV15 Multifunctional electrical energy meters for top-hat rail installation or panel mounting Application For measuring voltage, frequency, current, power, as well

More information

AND COMMUNICATION MODULES

AND COMMUNICATION MODULES Page -4 Page -4 MICRO PCs 10 Inputs/Outputs (RD10...) 12 Inputs/Outputs (RD12...) Inputs/Outputs (RD...) 12VDC,, or 100-240VAC power supply Relay or transistor outputs. EXPANSION AND COMMUNICATION MODUES

More information

SLI 15 INVERTER SERIES, 1500 W

SLI 15 INVERTER SERIES, 1500 W SLI 15 INVERTER SERIES, 1500 W FEATURES DESCRIPTION New, compact design: 1U height x 19" width x 14.94" depth; 19" rack-mountable High efficiency: up to 93% True sine wave output Parallelable output with

More information

PowerView Model PV450. Installation and Operation Manual Section 78

PowerView Model PV450. Installation and Operation Manual Section 78 PowerView Model PV450 Installation and Operation Manual 00-02-0732 05-19-2011 Section 78 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our

More information

EP-ELVCTL Elevator Control (NION-16C48M)

EP-ELVCTL Elevator Control (NION-16C48M) EP-ELVCTL Elevator Control (NION-16C48M) Product Installation Document This document covers the procedures and specifications for installing the above listed unit and when appropriate, information regarding

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

CM6800E Matrix Switcher/Controller MICROPROCESSOR-BASED, CROSS-POINT VIDEO SWITCHER, 48 X 8, EXPANDABLE

CM6800E Matrix Switcher/Controller MICROPROCESSOR-BASED, CROSS-POINT VIDEO SWITCHER, 48 X 8, EXPANDABLE PRODUCT SPECIFICATION analog systems and controls CM6800E Matrix Switcher/Controller MICROPROCESSOR-BASED, CROSS-POINT VIDEO SWITCHER, 48 X 8, EXPANDABLE Product Features 48 Video Inputs, 8 Video Outputs;

More information

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter PM130 PLUS POWER METER The PM130 PLUS is a compact, multi-function, three-phase AC powermeter specially designed to meet the requirements of users ranging from electrical panel builders to substation operators.

More information

PHOENIX CONTACT Features

PHOENIX CONTACT Features 36 to 120 k for small installation protection Data Sheet 2789_en_F 1 Description PHOEIX OTT 2011-04-29 2 Features The (SPD) provides surge protection in a compact, affordable package. high-energy suppression

More information

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers. General Information CFW10 CFW100 CFW08 CFW500 CFW700 CFW701 CFW11 EDP11 CFW11M SSW05 SSW07 GPH2 TPH2 The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which

More information

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values CT/VT Interface 560CVT10 The fault current is measured up to 20 times nominal current. Therefore the current inputs withstand 50 times nominal current for 1 s. The CT/VT interface is equipped with one

More information

Spectra RMS Circuit Breakers with microentelliguard Trip Units

Spectra RMS Circuit Breakers with microentelliguard Trip Units GE Energy Industrial Solutions Spectra RMS Circuit Breakers with microentelliguard Trip Units Greater system coordination, arc flash protection and reliability for new equipment and retrofit applications

More information

LE ELECTRONICS Pvt. Ltd.

LE ELECTRONICS Pvt. Ltd. LE ELECTRONICS Pvt. Ltd. Monitoring Relays: LVM Line Voltage Monitors LCM - Line Current Monitors VMR Voltage Monitoring Relays CMR Current Monitoring Relays VCMR Voltage Current Monitoring Relays LFM

More information

MODEL: MAT3. [2] ALARM OUTPUT A: With Y: Without. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MAT3. [2] ALARM OUTPUT A: With Y: Without. Lightning Surge Protectors for Electronics Equipment M-RESTER MODEL: MAT Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTI SURE PROTETOR FOR THREE-PHASE POWER SUPPLY Functions & Features onnected in parallel between the power and earth lines regardless

More information

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology HGM9580 Bus Tie Bus Parallel Unit USER MANUAL Smartgen Technology This manual is suitable for HGM9580 bus tie bus parallel unit only. Clarification of notation used within this publication. SIGN INSTRUCTION

More information

DMT345 and DMT346 Dewpoint Transmitters

DMT345 and DMT346 Dewpoint Transmitters DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662

More information

Comprehensive Modular Genset Controller

Comprehensive Modular Genset Controller Inteligen Learn More Comprehensive Modular Genset Controller Brief Description The Inteligen is a comprehensive controller for single and multiple generating sets operating in standby or parallel to the

More information