1 PRODUCT DATA SHEET ACTUATOR LA25 Features and Options: 12 or 24 V DC permanent magnetic motor 900 N N load in push and pull Colour: Dark olive grey Protection class: IP66, furthermore the actuator can be washed down by a high pressure cleaner (IP69K static) Stroke length from mm Positioning options: Hall potentiometer, Hall PWM or Single Hall End of Stroke signal (EOS) Back fixture and piston rod eye material: Steel or stainless steel Heavy duty aluminium housing for harsh conditions Guided nut Safety nut in push or pull (2500N version only safety nut in push) Built-in electrical endstop Exchangeable cable Static safety factor: 2.0 Noise level: Max db(a) (At nominal voltage and with no load, according to EN ISO ) IC options including IC and Parallel Special anodised housing for extreme environments Usage: Duty cycle: 20%, 2 minutes continuous use followed by 8 minutes not in use Ambient temperature: -40 C to +85 C, full performance from +5 C to +40 C Storage temperature: -55 C to +105 C The LA25 is compatible with SMPS-T160 With its robust design, high IP degree and aluminium housing, the actuator LA25 is ideal for harsh environments where operation under extreme conditions is required. Furthermore, the compact dimensions of the LA25 make it applicable for confined spaces. This TECHLINE actuator comes with IC - Integrated controller. For more information on our IC options, please see: Page 1 of 24

2 Contents Technical specifications LA LA25 standard cable item numbers... 3 Speed, load and current curves LA25 Ordering example... 6 LA25 dimensions & Stroke tolerances... 7 Built-in dimensions... 8 LA25 Piston Rod Eyes... 9 LA25 Back fixture orientation...10 I/O Specifications: Actuator without feedback I/O Specifications: Actuator with endstop signal output I/O Specifications: Actuator with relative positioning - Single Hall...12 I/O Specifications: Actuator with endstop signals and relative positioning - Single Hall I/O Specifications: Actuator with absolute positioning - Analogue feedback...14 I/O Specifications: Actuator with endstop signals and absolute positioning - Analogue feedback...15 I/O Specifications: Actuator with absolute positioning - PWM...16 I/O Specifications: Actuator with endstop signals and absolute positioning - PWM I/O Specifications: Actuator with IC Basic I/O Specifications: Actuator with IC Advanced - with BusLink I/O Specifications: Actuator with Parallel...21 Environmental tests Climatic Environmental tests - Mechanical...23 Complying standards...24 Non-complying standards Page 2 of 24

3 Technical specifications LA25 12V: Push/Pull Max. (N) Self-lock min. (N) Push/Pull Without short circuit With short circuit Spindle pitch (mm) *Typical speed (mm/s) Standard stroke *Typical 12 V No load Full load length (mm) No load Full load V: Push/Pull Max. (N) Self-lock min. (N) Push/Pull Without short circuit With short circuit Spindle pitch (mm) *Typical speed (mm/s) Standard stroke *Typical 24 V No load Full load length (mm) No load Full load * The typical values can have a variation of ± 20% on the current values and ± 10% on the speed values. Measurements are made with an actuator in connection with a stable power supply and an ambient temperature at 20 C. LA25 standard cable item numbers LA25 cable item no. Length (mm) outside the actuator Page 3 of 24

4 Speed, load and current curves 12V motor, type A The values below are typical values made with a stable power supply and an ambient temperature at 20 C 14 LA25-12V Speed vs Thrust Speed [mm/s] mm pitch 6mm pitch 9mm pitch 12mm pitch Thrust [N] LA25-12V Current vs Thrust 4,5 4 3,5 3 Current [A] 2,5 2 1,5 3mm pitch 6mm pitch 9mm pitch 12mm pitch 1 0, Thrust [N] Page 4 of 24

5 Speed, load and current curves 24V motor, type B The values below are typical values made with a stable power supply and an ambient temperature at 20 C 14 LA25-24V Speed vs Thrust Speed [mm/s] mm pitch 6mm pitch 9mm pitch 12mm pitch Thrust [N] LA25-24V Current vs Thrust 2 1,8 1,6 1,4 Current [A] 1,2 1 0,8 0,6 3mm pitch 6mm pitch 9mm pitch 12mm pitch 0,4 0, Thrust [N] Page 5 of 24

6 LA25 Ordering example: 2 5 P P P X X X S S F F P M E E = B R E P C E F L 0 0 X X X XXX = BID (mm) 0 = Not specified 0 = Not specified Loadtype 0 = Push/Pull 1 = Push 2 = Pull * Feedback level by platform type None IC type Basic IC type Advanced IC type Parallel 0 = none 0 = none 0 = none Z = Parallel 1 = 0-10 V 1 = 0-10 V A = 0-10 V 2 = V B = V 3 = 4-20 ma C = 4-20 ma 4 = % D = % 5 = % E = % 9 = Special X = Special EOS (End Of Stroke) output 0 = No (only IC Basic) 1 = Yes (only IC Advanced) Cable: 0 = None S = Straight 0.75m T = Straight 1.5m (8-core, Note: If AMP is chosen = 6-core) R = Straight 5.0m (8-core, Note: If AMP is chosen = 6-core) X = Special Plug Type: 0 = None Is to be chosen, if cable and connectors are not wanted C = Flying leads Is to be chosen, if connector is not wanted J = Deutsch (DT4) K= AMP superseal X = Special Piston Rod Eye: 1 = Zink coated steel ø10,2 ( ) A = Stainless ø10.2 ( ) 2 = Zink coated steel + bushings ø10.2 B = Stainless + bushings ø = Zink coated ø 12.3 ( ) C = Stainless ø 12.3 ( ) 4 = Zinc coated steel + bushings ø 8.1 D = Stainless steel + bushings ø 8.1 X = special Backfixture rotation 1 = 0 degrees 2 = 90 degrees Back fixture type: 1 = Zink coated steel ø10.2 ( ) A = Stainless ø10.2 ( ) 2 = Zink coated steel + bushings ø10.2 B = Stainless + bushings ø = Zink coated ø 12.3 ( ) C = Stainless ø 12.3 ( ) 4 = Zinc coated steel + bushings ø 8.1 D = Stainless steel + bushings ø 8.1 X = special Colour : IP: Endstop : = = DarkGrey A= IP66 9 = Harsh environment housing (Special article number only) T = ATEX 0 = Power switch (Platform none) 1 = Signalswitch (Platform IC) Motor Type: Platform A = 12VDC normal B = 24VDC Normal 0 = None 3 = IC Integrated Controller Feedback Safety : 00 = None 0K = Single Hall 0A = Hall Potentiometer (Analogue feedback) 0F = PWM 00 = None 0A = Safety nut Stroke Length: Spindle Pitch: Actuator Type: XXX = mm 030 = 3 mm 060 = 6 mm 090 = 9 mm 120 = 12 mm 25 = LA25 Note: When the built-in dimensions (BID) are special, write xxx when ordering, write stroke + BID in system specification. Noise can occur if plastic bushings are not fitted in the Piston rod eye / Back fixture * IC options: IC LINbus Parallel LA25 actuator: Page 6 of 24

7 LA25 Dimensions Stroke tolerances: Platform options Descriptions Stroke tolerance Example for 200 mm stroke 25XXXXXXXXXX0 With built-in limit switches + 2 / - 2 mm 198 to 202 mm 25XXXXXXXXXX3 Integrated controller + 1 / - 3 mm 197 to 201 mm Built-in tolerances: Platform options Descriptions BID tolerance Example for 200 mm BID 25XXXXXXXXXXX All variants + 2 / - 2 mm 198 to 202 mm Page 7 of 24

8 Built-in dimensions: The built-in dimension depends upon the chosen safety option and stroke length. Please see the table below to decide upon the built-in dimension. Safety option Stroke length Spindle pitch Min. built-in Dimensions No safety option , 9 or No safety option Safety nut for push , 9 or Safety nut for push Safety nut for pull , 9 or No safety option , 9 or stroke No safety option stroke Safety nut for push , 9 or stroke Safety nut for push stroke Safety nut for pull , 9 or stroke No safety option , 9 or stroke No safety option stroke Safety nut for push , 9 or stroke Safety nut for push stroke Safety nut for pull , 9 or stroke Page 8 of 24

9 LA25 Piston Rod Eyes: Piston: , Zinc coated Piston: , Stainless steel AISI 304 Piston: , Zinc coated Piston: , Stainless steel AISI 304 Page 9 of 24

10 LA25 Back fixture orientation: Option 1 = 0 Option 2 = 90 Page 10 of 24

11 I/O specifications: Actuator without feedback: Input/Output Specification Comments Description Permanent magnetic DC motor. Brown V DC (+/-) Blue Red Recommended fuse for 12V is 8 Amp and for 24V it is 4 Amp Connect Brown to positive Connect Brown to negative Connect Blue to negative Connect Blue to positive Black Green Yellow Violet White I/O specifications: Actuator with endstop signal output Input/Output Specification Comments Description The actuator can be equipped with electronically controlled endstop signals out. IN OUT Brown V DC (+/-) Blue Recommended fuse for 12 V is 8 Amp and for 24 V it is 4 Amp Red Signal power supply (+) V DC Black Signal power supply GND (-) Connect Brown to positive Connect Brown to negative Connect Blue to negative Connect Blue to positive Current consumption: Max. 40 ma, also when the actuator is not running Green Endstop signal out Output voltage min. V IN - 2V Source current max. 100 ma Yellow Endstop signal in NOT potential free Violet White Page 11 of 24

12 I/O Specifications: Actuator with relative positioning - Single Hall Input/Output Specification Comments Description The actuator can be equipped with Single Hall that gives a relative positioning feedback signal when the actuator moves. Brown V DC (+/-) Blue Recommended fuse for 12 V is 8 Amp and for 24 V it is 4 Amp Red Signal power supply (+) V DC Black Signal power supply GND (-) Connect Brown to positive Connect Brown to negative Connect Blue to negative Connect Blue to positive Current consumption: Max. 40 ma, also when the actuator is not running Green Yellow Violet Single Hall output (PNP) Movement per single Hall pulse: LA25030 Actuator = 0.25 mm per pulse LA25060 Actuator = 0.5 mm per pulse LA25090 Actuator = 0.75 mm per pulse LA25120 Actuator = 1.0 mm per pulse Frequency: Frequency is Hz on Single Hall output depending on load. Pulse ON time is minimum 8ms.OFF time between two ON pulses is minimum 8ms. Overvoltage on the motor can result in shorter pulses. Diagram of Single Hall: Input Output voltage min. V IN - 2V Max. current output: 12 ma Max. 680 nf N.B. For more precise measurements, please contact LINAK A/S. Low frequency with a high load. Higher frequency with no load. Single Hall output Hall A Hall B Micro - Processor Fig.1 White Page 12 of 24

13 I/O Specifications: Actuator with endstop signals and relative positioning - Single Hall: Input/Output Specification Comments Description The actuator can be equipped with Single Hall that gives a relative positioning feedback signal when the actuator moves. Brown V DC (+/-) Blue Recommended fuse for 12 V is 8 Amp and for 24 V it is 4 Amp Red Signal power supply (+) V DC Black Signal power supply GND (-) Connect Brown to positive Connect Brown to negative Connect Blue to negative Connect Blue to positive Current consumption: Max. 40 ma, also when the actuator is not running Green Endstop signal out Output voltage min. V IN - 2V Source current max. 100 ma Yellow Endstop signal in NOT potential free Violet Single Hall output (PNP) Movement per single Hall pulse: LA25030 Actuator = 0.25 mm per pulse LA25060 Actuator = 0.5 mm per pulse LA25090 Actuator = 0.75 mm per pulse LA25120 Actuator = 1.0 mm per pulse Frequency: Frequency is Hz on Single Hall output depending on load. Pulse ON time is minimum 8ms. OFF time between two ON pulses is minimum 8ms. Overvoltage on the motor can result in shorter pulses. Diagram of Single Hall: Input Output voltage min. V IN - 2V Max. current output: 12 ma Max. 680 nf N.B. For more precise measurements, please contact LINAK A/S. Low frequency with a high load. Higher frequency with no load. Single Hall output Hall A Hall B Micro - Processor Fig.2 White Page 13 of 24

14 I/O Specifications: Actuator with absolute positioning - Analogue feedback: Input/Output Specification Comments Description The actuator can be equipped with electronic circuit that gives an analogue feedback signal when the actuator moves. Brown V DC (+/-) Blue Recommended fuse for 12 V is 8 Amp and for 24 V it is 4 Amp Red Signal power supply (+) VDC Black Signal power supply GND (-) Connect Brown to positive Connect Brown to negative Connect Blue to negative Connect Blue to positive Current consumption: Max. 60 ma, also when the actuator is not running Green Yellow Violet Analogue feedback 0-10 V (Feedback level 1) V (Feedback level 2) Tolerances +/- 0.2 V Max. current output: 1 ma Ripple max. 200 mv Transaction delay max. 20 ms Linear feedback 0.5% Source current max. 1 ma 4-20 ma (Feedback level 3) Special (Feedback level 9) Tolerances +/- 0.2 ma Transaction delay 20ms Linear feedback 0.5% Output: Source Serial resistance: 12V max 300 ohm 24V max. 900 ohm For all analogue feedbacks it is recommendable to have the actuator to activate its limit switches on a regular basis, to ensure more precise positioning White Page 14 of 24

15 I/O specifications: Actuator with endstop signals and absolute positioning - Analogue feedback: Input/Output Specification Comments Description The actuator can be equipped with electronic circuit that gives an analogue feedback signal when the actuator moves. Brown V DC (+/-) Blue Recommended fuse for 12 V is 8 Amp and for 24 V it is 4 Amp Connect Brown to positive Connect Brown to negative Connect Blue to negative Connect Blue to positive Red Signal power supply (+) V DC Current consumption: Black Signal power supply GND (-) Max. 60 ma, also when the actuator is not running Green Endstop signal out Output voltage min. V IN - 2V Source current max. 100 ma Yellow Endstop signal in NOT potential free Violet Analogue feedback 0-10 V (Feedback level 1) V (Feedback level 2) Tolerances +/- 0.2 V Max. current output: 1 ma Ripple max. 200 mv Transaction delay max. 20 ms Linear feedback 0.5% Source current max. 1 ma 4-20 ma (Feedback level 3) Special (Feedback level 9) Tolerances +/- 0.2 ma Transaction delay 20ms Linear feedback 0.5% Output: Source Serial resistance: 12V max 300 ohm 24V max. 900 ohm For all analogue feedbacks it is recommendable to have the actuator to activate its limit switches on a regular basis, to ensure more precise positioning White Page 15 of 24

16 I/O Specifications: Actuator with absolute positioning - PWM: Input/Output Specification Comments Description The actuator can be equipped with electronic circuit that gives an analogue feedback signal when the actuator moves. Brown V DC (+/-) Blue Recommended fuse for 12 V is 8 Amp and for 24 V it is 4 Amp Red Signal power supply (+) V DC Black Signal power supply GND (-) Connect Brown to positive Connect Brown to negative Connect Blue to negative Connect Blue to positive Current consumption: Max. 40 ma, also when the actuator is not running Green Yellow Violet White Digital output feedback % (Feedback level 4) % (Feedback level 5) Special (Feedback level 9) Output voltage min. V IN - 2V Tolerances +/- 2% Max. current output: 12 ma It is recommendable to have the actuator to activate its limit switches on a regular basis, to ensure more precise positioning Page 16 of 24

17 I/O specifications: Actuator with endstop signals and absolute positioning - PWM Input/Output Specification Comments Description The actuator can be equipped with electronic circuit that gives an analogue feedback signal when the actuator moves. Brown V DC (+/-) Blue Recommended fuse for 12 V is 8 Amp and for 24 V it is 4 Amp Red Signal power supply (+) V DC Black Signal power supply GND (-) Connect Brown to positive Connect Brown to negative Connect Blue to negative Connect Blue to positive Current consumption: Max. 40 ma, also when the actuator is not running Green Endstop signal out Output voltage min. V IN - 2V Source current max. 100 ma Yellow Endstop signal in NOT potential free Violet White Digital output feedback % (Feedback level 4) % (Feedback level 5) Special (Feedback level 9) Output voltage min. V IN - 2V Tolerances +/- 2% Max. current output: 12 ma It is recommendable to have the actuator to activate its limit switches on a regular basis, to ensure more precise positioning Page 17 of 24

18 I/O Specifications: Actuator with IC Basic Input/Output Specification Comments Description Brown Blue Easy to use interface with integrated power electronics (H-bridge). The actuator can also be equipped with electronic circuit that gives an asolute or relative feedback signal. The version with IC option cannot be operated with PWM (power supply) V DC + (VCC) Connect Brown to positive 12V, current limit 8A 24V, current limit 5A VDC - (GND) Connect Blue to negative 12V, current limit 8A 24V, current limit 5A Note: Do not change the power supply polarity on the brown and blue wires! Power supply GND (-) is electrically connected to the housing If the temperature drops below -10 C, all current limits will automatically increase to 9A for 12V, and 6A for 24V Red Black Extends the actuator Retracts the actuator On/off voltages: > 67% of V IN = ON < 33% of V IN = OFF Input current: 10 ma M H-Bridge Green Yellow Violet Analogue feedback 0-10 V (Feedback level 1) Standby power consumption: 12 V, 60 ma 24 V, 45 ma Ripple max. 200 mv Transaction delay 20 ms Linear feedback 0.5% Max. current output: 1 ma It is recommendable to have the actuator to activate its limit switches on a regular basis, to ensure more precise positioning. White Single Hall output (PNP) Signal GND Output voltage min. V IN - 2V Max. current output: 12 ma For more information see fig.2, page 13 Page 18 of 24

19 I/O Specifications: Actuator with IC Advanced - with BusLink Input/Output Specification Comments Description Brown Blue Easy to use interface with integrated power electronics (H-bridge). The actuator can also be equipped with electronic circuit that gives an absolute or relative feedback signal. IC Advanced also provides a wide range of possibilities for customisation. The version with IC option cannot be operated with PWM (power supply) V DC + (VCC) Connect Brown to positive 12V, current limit 8A 24V, current limit 5A V DC - (GND) Connect Blue to negative 12V, current limit 8A 24V, current limit 5A Note: Do not change the power supply polarity on the brown and blue wires! Power supply GND (-) is electrically connected to the housing Current limit levels can be adjusted through BusLink If the temperature drops below -10 C, all current limits will automatically increase to 9A for 12V, and 6A for 24V Red Black Extends the actuator Retracts the actuator On/off voltages: > 67% of V IN = ON < 33% of V IN = OFF Input current: 10 ma Green Yellow Endstop signal out Endstop signal in Output voltage min. V IN - 2V Source current max. 100 ma Endstop signals are NOT potential free. Endstop signals can be configured with BusLink software according to any position needed. Only use one virtual endstop - keep one end open for initialisation. (See I/O specifications for endstop on page 11) M H-Bridge Page 19 of 24

20 I/O Specifications: Actuator with IC Advanced - with BusLink Input/Output Specification Comment Violet White Analogue feedback (0-10V): Configure any high/low combination between 0-10 V Single Hall output (PNP) Digital output feedback PWM: Configure any high/low combination between 0-100% Analogue feedback (4-20 ma): Configure any high/low combination between 4-20 ma All absolute value feedbacks (0-10V, PWM and 4-20 ma) Signal GND Ripple max. 200 mv Transaction delay 20 ms Linear feedback 0.5% Max. current output. 1 ma Output voltage min. V IN - 2V Max. current output: 12 ma Please be aware that when choosing single hall, feedback position readout and virtual endstops are not available in BusLink. For more information, see fig. 2, page 13 Output voltage min. V IN -2V Frequency: 75 Hz ± 10 Hz as standard, but this can be customised. Duty cycle: Any low/high combination between 0 and 100 percent. Open Drain source current max. 12 ma Tolerances +/- 0.2 ma Transaction delay 20 ms Linear feedback 0.5% Output: Source Serial resistance: 12 V max. 300 ohm 24 V max. 900 ohm Standby power consumption: 12 V, 60 ma 24 V, 45 ma It is recommendable to have the actuator to activate its limit switches on a regular basis, to ensure more precise positioning BusLink is available for IC Advanced and can be used for: Diagnostics, manual run and configuration Please note that the BusLink cables must be purchased separately from the actuator! Item numbers for BusLink cables: USB2LIN: USB2LIN05, USB2LIN06 and onwards Adaptor cable: Page 20 of 24

21 I/O specifications: Actuator with Parallel Input/Output Specification Comments Description Brown Blue Parallel drive of up to 8 actuators. A master actuator with an integrated H-bridge controller controls up to 7 slaves. The version with IC option cannot be operated with PWM (power supply) V DC + (VCC) Connect Brown to positive 12V, current limit 8A 24V, current limit 5A V DC - (GND) Connect Blue to negative 12V, current limit 8A 24V, current limit 5A Note: Do not change the power supply polarity on the brown and blue wires! The parallel actuators can run on one OR separate power supplies Power supply GND (-) is electrically connected to the housing Current limit levels can be adjusted through BusLink (only one actuator at a time for parallel) If the temperature drops below -10 C, all current limits will automatically increase to 9A for 12V, and 6A for 24V Red Black Extends the actuator Retracts the actuator On/off voltages: > 67% of V IN = ON < 33% of V IN = OFF Input current: 10 ma It does not matter where the in/out signals are applied. You can either choose to connect the signal cable to one actuator OR you can choose to connect the signal cable to each actuator on the line. Either way this will ensure parallel drive Green Endstop signal out Output voltage min. V IN - 2V Source current max. 100 ma Yellow Endstop signal in NOT potential free M H-Bridge M H-Bridge M H-Bridge M H-Bridge Violet White Parallel communication: Violet cords must be connected together Signal GND: White cords must be connected together Standby power consumption: 12 V, 60 ma 24 V, 45 ma No feedback available during parallel drive BusLink is available for Parallel and can be used for: Diagnostics Service counter is available with Parallel Parallel actuator configurations can be changed through BusLink, but all actuators need the same configurations! Please note that the BusLink cables must be purchased separately from the actuator! Item numbers for BusLink cables: USB2LIN: USB2LIN05, USB2LIN06 and onwards Adaptor cable: Page 21 of 24

22 Environmental tests Climatic Test Specification Comment TRD number Cold test EN (Ab) Storage at low temperature: Temperature: - 40 C Duration: 72 h Actuator is not connected/operated Tested at room temperature EN (Ad) Storage at low temperature: Temperature: -55 C Duration: 24 h Actuator is not connected Tested at room temperature Operating at low temperature: Temperature: -40 C Duration: 4 h Tested at room temperature within 5 minutes overload Dry heat EN (Bb) Storage at high temperature: Temperature: +85 C Duration: 72 h Actuator is not connected/operated Tested at room temperature EN (Bb) Storage at low temperature: Temperature: +105 C Duration: 24 h Actuator operated at high temperature Damp heat EN (Db) Damp heat, Cyclic: Relative humidity: % High temperature: +55 C in 12 hours Low temperature: +25 C in 12 hours Duration: 21 cycles * 24 hours Actuator is operated during test Salt mist. EN ISO 9227 Dynamic salt spray test: Salt solution: 5% sodium chloride (NaCl) Temperature: 35 ± 2 C Duration: 500 h Actuator is operated Thermal shock Dunk test: Actuator is heated to +85 C for 4 h and submerged into a 0 C cold saltwater-detergent solution for 2 h Followed by 18 h dry time Duration: 5 cycles TRD5675 TRD5675 TRD5675 TRD5675 TRD5677 TRD5678 TRD5679 Page 22 of 24

23 Degrees of protection EN IP66 IP6X - Dust: Dust-tight, No ingress of dust Actuator is not activated TRD5680 Rain EN IP66 DIN IP69K IPX6 - Water: Ingress of water in quantities causing harmful effects is not allowed Duration: 100 litres pr. minute in 3 minutes Actuator is not activated IPX9K: High pressure cleaner Temperature: +80 C Water pressure: bar Water flow: l/min Duration: 30 sec. each at 4 different angles 0, 30, 60 and 90 Actuator is not activated Ingress of water in quantities causing harmful effects is not allowed Dynamic rain test: Actuators exposed to continous rain Actuators operated and side loaded with 5N Duration: cycles and 240 h TRD5682 TRD5680 TRD5681 Environmental tests - Mechanical Test Specification Comment TRD number Mechanical Shock (Handling) - Drop test Mechanical Shock Operational Vibration Random 3 drops on 6 faces onto a concrete floor. Drop height: 500 mm on all faces Peak Pulse Amplitude: 50 G Pulse Duration: 11 ms Number of pulses: 18 total - 3 in each direction for all three axis Peak Pulse Amplitude: 30 G Pulse Duration: 18 ms Number of pulses: 18 total - 3 in each direction for all three axis Peak Pulse Amplitude: 25 G Pulse Duration: 6 ms Number of pulses: 6000 total in each direction for all three axis Random vibration: From 18 Hz to 1000 Hz Duration: 2 h/axis TRD5683 TRD5684 TRD5684 TRD5684 TRD5684 Page 23 of 24

24 Complying standards: Standard Specification FOCUS ON 2004/104/EC EN/IEC : A1: 2009 EN/IEC : 2008 Automotive EMC Directive 2004/104/EC on electrical and electronic car components Safety of machinery - Electrical equipment of machines - Part 1: General requirements Safety of machinery - Electrical equipment of machines - Part 32: Requirements for hoisting machines VEHICLES AND MOBILITY INDUSTRIAL AUTOMATION INDUSTRIAL AUTOMATION PLATFORMS AND LIFTS EN/IEC : 2007 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for industrial environments INDUSTRIAL AUTOMATION EN/IEC : 2005 EN/IEC : A1:2011 EN/IEC : A1:2011 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments Electromagnetic compatibility (EMC) - Part 6: Generic standards - Section 4: Emission standard for industrial environments INDUSTRIAL AUTOMATION INDUSTRIAL AUTOMATION INDUSTRIAL AUTOMATION EN 13309: 2010 Construction machinery CONSTRUCTION EN/ISO 13766: 2006 Earth-moving machinery - Electromagnetic compatibility CONSTRUCTION EN/ISO 14982: 2009 EU recreational crafts directive 94/25/EC Non-complying standards: Standard 2004/104/EC Agricultural and forestry machines - Electromagnetic compatibility Explanation MOBILE AGRICULTURE OUTDOOR POWER EQUIPMENT Please note that this product cannot be approved according to the medical electrical equipment standard. Due to the combination of the aluminium cast housing and the embedded PCB, we do not fulfill the regulations according to leakage current. Copyright LINAK MA M E. Chapter 5.21 Terms of use The user is responsible for determining the suitability of LINAK products for specific application. LINAK takes great care in providing accurate and up-to-date information on its products. However, due to continuous development in order to improve its products, LINAK products are subject to frequent modifications and changes without prior notice. Therefore, LINAK cannot guarantee the correct and actual status of said information on its products. While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the same reasons as mentioned above, guarantee the availability of any particular product. Therefore, LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK. All sales are subject to the Standard Terms of Sale and Delivery for LINAK. For a copy hereof, please contact LINAK. Page 24 of 24 FOR MOUNTING INSTRUCTIONS AND GUIDANCE IN USAGE, PLEASE SEE THE RELEVANT USER S MANUALS

Actuator LA33. Data sheet LINAK.COM/TECHLINE

Actuator LA33. Data sheet LINAK.COM/TECHLINE Actuator LA33 Data sheet LINAK.COM/TECHLINE LA33 The actuator LA33 is a true mid-size actuator that combines compact design and high power in one solution, fit for use in the most extreme environments.

More information

ACTUATOR LA36 PRODUCT DATA SHEET. Page 1 of 32

ACTUATOR LA36 PRODUCT DATA SHEET. Page 1 of 32 PRODUCT DATA SHEET ACTUATOR LA36 Features: 12, 24 or 36 V DC Permanent magnetic motor (IC only 12/24 V DC) Thrust from 500 N - 10,000 N depending on gear ratio and spindle pitch 10,000 N actuator cannot

More information

TECHLINE SYSTEM SOLUTIONS

TECHLINE SYSTEM SOLUTIONS TECHLINE SYSTEM SOLUTIONS www.linak.com/techline Plug & Play with LINAK system solutions TECHLINE system solutions improve functionality and add value to your application. Our systems offer: Simple Plug

More information

Actuator LA37 Data sheet LINAK.COM/TECHLINE

Actuator LA37 Data sheet LINAK.COM/TECHLINE Actuator LA37 Data sheet LINAK.COM/TECHLINE LA37 Tough applications require equally tough actuator solutions. The actuator LA37 is specifically developed for heavyduty applications in harsh environments,

More information

Actuator LA31. Data sheet LINAK.COM/DESKLINE

Actuator LA31. Data sheet LINAK.COM/DESKLINE Actuator LA31 Data sheet LINAK.COM/DESKLINE LA31 The LA31 actuator is a very quiet and powerful linear actuator desigend for a variety of desk applications ranging from kitchen applications to industrial

More information

Actuator LA37 User manual LINAK.COM/TECHLINE. Page 1 of 80

Actuator LA37 User manual LINAK.COM/TECHLINE. Page 1 of 80 Actuator LA37 User manual LINAK.COM/TECHLINE Page 1 of 80 Contents Preface...4 LINAK application policy...5 Chapter 1 Safety instructions...6-7 Chapter 2 Mounting guidelines...8-11 Mounting of cables...12

More information

TECHLINE iflex integrated Flexibility

TECHLINE iflex integrated Flexibility TECHLINE iflex integrated Flexibility No control boxes. Fewer cables. Smarter options This is iflex TECHLINE actuators with iflex all feature an integrated H-bridge controller. This is why an iflex solution

More information

Focus on Pergolas LINAK.COM/TECHLINE

Focus on Pergolas LINAK.COM/TECHLINE Focus on Pergolas LINAK.COM/TECHLINE When partnering with LINAK you get more than just a product in your hands. It is our goal to create added value to our customers by offering innovative solutions, extensive

More information

Actuator LA25 User manual LINAK.COM/TECHLINE. Page 1 of 76

Actuator LA25 User manual LINAK.COM/TECHLINE. Page 1 of 76 Actuator LA25 User manual LINAK.COM/TECHLINE Page 1 of 76 Contents Preface... 4 LINAK application policy... 5 Chapter 1 Safety instructions... 6-7 IECEx/ATEX... 8-9 Chapter 2 Mounting guidelines... 10-11

More information

TECHLINE Product Overview

TECHLINE Product Overview TECHLINE Product Overview Actuators LA37 Tough applications require equally tough actuator solutions. The actuator LA37 is specifically developed for heavy-duty applications in harsh environments, where

More information

Focus on Wastewater treatment LINAK.COM/TECHLINE

Focus on Wastewater treatment LINAK.COM/TECHLINE Focus on Wastewater treatment LINAK.COM/TECHLINE Reliable and optimised solutions for wastewater treatment In the wastewater industry easy control and monitoring are key elements for ensuring optimal day-to-day

More information

TECHLINE Product overview LINAK.COM/TECHLINE

TECHLINE Product overview LINAK.COM/TECHLINE TECHLINE Product overview LINAK.COM/TECHLINE Actuators LA37 Tough applications require equally tough actuator solutions. The actuator LA37 is specifically developed for heavy-duty applications in harsh

More information

Actuator LA27. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA27. Data sheet LINAK.COM/MEDLINE-CARELINE Actuator LA7 Data sheet LINAK.COM/MEDLINECARELINE LA7 The LA7 actuator is a powerful actuator designed for applications such as furniture and home carebeds. The LA7 actuator is developed for both push

More information

Actuator LA36 User manual LINAK.COM/TECHLINE. Page 1 of 92

Actuator LA36 User manual LINAK.COM/TECHLINE. Page 1 of 92 Actuator LA36 User manual LINAK.COM/TECHLINE Page 1 of 92 Contents Preface...5 LINAK application policy...6 Chapter 1 Safety instructions... 7-8 IECEx/ATEX... 9-10 Chapter 2 Mounting guidelines... 11-12

More information

Built-in DB6. Data sheet LINAK.COM/DESKLINE

Built-in DB6. Data sheet LINAK.COM/DESKLINE Built-in DB6 Data sheet LINAK.COM/DESKLINE Built-in DB6 The DESKLIFT DB6 is a built-in actuator specially made for desks with a high adjustment range. The DB6 (DESKLINE Built-in) is a three part telescopic

More information

DL8. Data sheet LINAK.COM/DESKLINE

DL8. Data sheet LINAK.COM/DESKLINE DL8 Data sheet LINAK.COM/DESKLINE DL8 The DL8 is a 2-part DESKLINE column with round profiles. The upside down construction gives a very compact and clean design, which also arises from the fact that the

More information

Actuator MD56. Product Data Sheet Feature. Option

Actuator MD56. Product Data Sheet   Feature. Option Product Data Sheet www.moteck.com Actuator MD5 MD5 is a powerful but compact actuator up to 5000N max. thrust that is suitable for wide range of applications including medical, homecare, furniture and

More information

DL2. Data sheet LINAK.COM/DESKLINE

DL2. Data sheet LINAK.COM/DESKLINE DL2 Data sheet LINAK.COM/DESKLINE DL2 The DESKLINE DL2 column is designed for a wide range of workstation applications and it is the ideal choice for duties such as height adjustment of computer workstations,

More information

Desklift DL10. Data sheet LINAK.COM/DESKLINE

Desklift DL10. Data sheet LINAK.COM/DESKLINE Desklift DL1 Data sheet LINAK.COM/DESKLINE DL1 The DESKLIFT DL1 is a round 2-part column perfect for a wide range of different desk applications. The column is very compact and clean in design, which also

More information

DESKLIFT DL5 PRODUCT DATA SHEET

DESKLIFT DL5 PRODUCT DATA SHEET PRODUCT DATA SHEET DESKLIFT DL Features: Compact design where guide and actuator function are an integrated unit Short cable mounted on the DL for connection to CBD4/CBD/CBD6 with separate DESKLINE motor

More information

DESKLIFT TM DL5. Data sheet LINAK.COM/DESKLINE

DESKLIFT TM DL5. Data sheet LINAK.COM/DESKLINE DESKLIFT TM DL5 Data sheet LINAK.COM/DESKLINE DESKLIFT TM DL5 The DESKLIFT DL5 is a compact 2-part lifting column, which is a perfect choice for a wide range of different desk applications, especially

More information

LA Series In-line Linear Actuators

LA Series In-line Linear Actuators LA Series In-line Linear Actuators Innovative, patented design for better life High quality, CE marked 6 size in diameter available: 16mm, 26mm, 35mm, 38mm, 45mm, 52mm High load capacity with precision

More information

DC Connector. Data sheet LINAK.COM/HOMELINE

DC Connector. Data sheet LINAK.COM/HOMELINE DC Connector Data sheet LINAK.COM/HOMELINE DC Connector The DC CONNECTOR is a HOMELINE accessory making it possible to connect a variety of standard articles equipped with a DC plug to your TWINDRIVE TD3

More information

SENSORS INCLINOMETERS... SN4 LENGTH AND ANGLE SENSORS... SN6 SLIP-IN SPOOL POSITION TRANSDUCER... SN8 PROXIMITY SENSOR... SN10 MATERIAL SENSOR...

SENSORS INCLINOMETERS... SN4 LENGTH AND ANGLE SENSORS... SN6 SLIP-IN SPOOL POSITION TRANSDUCER... SN8 PROXIMITY SENSOR... SN10 MATERIAL SENSOR... Section / Description page INCLINOMETERS... SN4 LENGTH AND ANGLE SENSORS... SN6 SLIP-IN SPOOL POSITION TRANSDUCER... SN8 PROXIMITY SENSOR... SN10 MATERIAL SENSOR... SN11 ACCESSORIES... SN12 Page SN1 Page

More information

Control Box CO61. Data sheet LINAK.COM/MEDLINE-CARELINE

Control Box CO61. Data sheet LINAK.COM/MEDLINE-CARELINE Control Box CO61 Data sheet LINAK.COM/MEDLINE-CARELINE C061 The LINAK control box CO61 offers a consolidated range of unprecedented features all utilising standardised technology, interfaces and compatibility.

More information

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301 Instruction book IQAN-LSL Publ no HY17-8367/UK Edition 0301 Contents 1 Introduction......................................................2 2 Precautions.......................................................3

More information

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

Instruction book IQAN-LST. Publ no HY /UK Edition 0301 Instruction book IQAN-LST Publ no HY17-8364/UK Edition 0301 Contents 1 Introduction......................................................2 2 Precautions.......................................................3

More information

Actuator FD61. Product Data Sheet Feature. Option

Actuator FD61. Product Data Sheet   Feature. Option Product Data Sheet www.moteck.com FD61 FD61 is a quiet and powerful actuator designed for use in furniture application. Compared to FD6, the motor size of FD61 is more compact. There are several models

More information

Photoelectrics Retro-reflective, Polarized Type PA18C.P..., DC

Photoelectrics Retro-reflective, Polarized Type PA18C.P..., DC Photoelectrics Retro-reflective, Polarized Type PA18C.P..., DC Miniature sensor range Range: 5 m (axial), 4 m (radial) Sensitivity adjustment by potentiometer Modulated, red light 625 nm Supply voltage:

More information

iswitch imotor Compact QR

iswitch imotor Compact QR PRODUCT DATA SHEET iswitch imotor Compact QR Features: Compact design Fit for purpose Suitable for 2 feeder switches Quick Release for manual operation High operation torque Operation monitoring (max.

More information

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI711S / / 2010 Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding

More information

Photoelectrics Retro-reflective Type PA18C.R..., DC

Photoelectrics Retro-reflective Type PA18C.R..., DC Photoelectrics Retro-reflective Type PA18C.R..., DC Miniature sensor range Range: 6.5 m (Axial), 5 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to

More information

LA Series In-line Linear Actuators

LA Series In-line Linear Actuators LA Series In-line Linear Actuators High quality, CE marked High load capacity with precision and synchronous control 6000N load max., speed up to 55mm/s IP66 protection; water and dust proof Low energy

More information

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz Description Operation mode and max sensing range: Diffuse proximity: 0-5 m Background suppression: 0- m Compact rectangular housing (x mm) Cable or rotatable plug connection via potentiometer Switch selectable

More information

Photoelectrics Diffuse-reflective Type PA18C.D..., DC

Photoelectrics Diffuse-reflective Type PA18C.D..., DC Photoelectrics Diffuse-reflective Type PA18C.D..., DC Miniature sensor range Range: 1 m (Axial), 0.8 m (Radial) Sensitivity adjustment by potentiometer Modulated, red light 625 nm Supply voltage: to 30

More information

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous

More information

Linear Position Transducer HLT 1000-R2

Linear Position Transducer HLT 1000-R2 Linear Position Transducer HLT 1000-R2 Description: The sensor works on the principle of magnetostriction. This measuring principle determines with high accuracy the position, distance and/or speed and

More information

Control Box CB16 OpenBus TM. Data sheet LINAK.COM/MEDLINE-CARELINE

Control Box CB16 OpenBus TM. Data sheet LINAK.COM/MEDLINE-CARELINE Control Box CB16 OpenBus TM Data sheet LINAK.COM/MEDLINE-CARELINE CB16 OpenBus TM CB16 is part of the LINAK OpenBus product range. It is a powerful control box with either traditional transformer solution

More information

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900 NOVOHALL Rotary Sensor non-contacting Series RSX-7900 Special features very robust design to extreme environmental conditions high shaft load 300 N non-contacting, magnetic measuring angles up to 360 in

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Data Sheet for Joysticks

Data Sheet for Joysticks Finger Joystick Series 87 Dual redundant outputs IP67 sealed lever heights: 8mm and 60mm 5 lever colors Series 87 is offering paddle joysticks of high precision and quality - claims that are not only supported

More information

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

VER05 Series. xxx Series. 5 Watt.   AC-DC Power Supplies. Models & Ratings. Input. Output 5 Watt xxx Series Energy Efficiency Level VI Barrel Jack & USB Versions Interchangeable Mains Connectors Included Universal Input Output Voltages from 5.0 V to 12.0 V Class II Construction Low Cost B R

More information

DDR-120 series. 120W DIN Rail Type DC-DC Converter

DDR-120 series. 120W DIN Rail Type DC-DC Converter is a DIN Rail type DC-DC converter with main features including DIN rail-type easy installation, : SPECIFICATION MODEL OUTPUT INPUT PROTECTION OTHERS NOTE DDR-120A-12 DDR-120A-24 DC VOLTAGE RATED CURRENT

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

VEL05 Series. xxx Series. 5 Watt.  AC-DC Power Supplies. Models & Ratings. Input 5 Watt xxx Series Energy Efficiency Level VI Barrel Jack & USB Versions Fixed Mains Connectors Universal Input Output Voltages from 5.0 V to 12.0 V Class II Construction Low Cost B R A N D The VEL05 series

More information

Photoelectrics Diffuse-reflective, Background Suppression Type PH18CNB20...

Photoelectrics Diffuse-reflective, Background Suppression Type PH18CNB20... Photoelectrics Diffuse-reflective, Background Suppression Type PH8CNB... Miniature sensor range Range: mm Sensitivity adjustment by potentiometer Modulated, red light 65 nm Supply voltage: to VDC Output:

More information

Power supply CP-C 24/5.0

Power supply CP-C 24/5.0 2CDC 271 064 F0004 Features Supply voltage ranges: 85-264 V AC, 100-350 V DC Output voltage adjustable from 22-28 V DC, default setting 24 V DC 0,5 % 5 A output current Open-circuit, overload and continous

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GF711S / / 2013 Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding

More information

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10 Model Number Features Solid shaft Up to 31 bit overall resolution CANopen interface Free of wear magnetic sampling High resolution and accuracy Highly shock / vibration and soiling resistant Sturdy construction

More information

Temposonics. R-Series Profibus. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm

Temposonics. R-Series Profibus. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm R-Series Temposonics Absolute, Non-Contact Position Sensors R-Series Temposonics RP and RH Measuring length 5-7600 mm Advanced Communication... offers Multi-Position Measurement Rugged Industrial Sensor

More information

Temposonics. R-Series Profibus. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm

Temposonics. R-Series Profibus. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm Temposonics Absolute, Non-Contact Position Sensors R-Series Temposonics RP and RH Stroke length 25 7600 mm Advanced Communication offers Multi-Position Measurement Rugged industrial sensor Linear and absolute

More information

MultiViu Flex 4 Data Sheet

MultiViu Flex 4 Data Sheet Division Interior MultiViu Flex 4 Data Sheet Description CAN-capable multifunction Solution Features: Robust and versatile design CAN-capability (SAE J1939, CANopen) Video interface Analogue and digital

More information

Hall-Effect Paddle Joystick

Hall-Effect Paddle Joystick Hall-Effect Paddle Joystick Robust design for arduous applications Return-to-center or return-to-end options Under-panel depth minimized to 9mm Rated for 5 million cycles Hall-effect sensor technology

More information

DDR-120 series. 120W DIN Rail Type DC-DC Converter

DDR-120 series. 120W DIN Rail Type DC-DC Converter DIN Rail Type DC-DC Converter + is a DIN Rail type DC-DC converter with main features including DIN rail-type easy installation, : DIN Rail Type DC-DC Converter SPECIFICATION MODEL OUTPUT INPUT PROTECTION

More information

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution GI55, GI56 Features Encoder with solid shaft ø mm or ø6 mm Max. 6000 pulses per revolution Optical sensing method Clamping or synchro flange Industrial standard High rotation speed up to 000 rpm Optional

More information

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview Feature rich J+J multi-voltage smart electric actuator with LED status light and function conversion kits. J3C-S20 Overview The J3C-S20 multi-voltage smart electric valve actuator from the European electric

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

Inclinometer. 4-20mA and RS232

Inclinometer. 4-20mA and RS232 Inclinometer 4-20mA and RS232 Real size Main Features - Two axis digital inclinometer n - Angle measurement range of +/-5, +/-15 and +/-30, Resolution up to 0.001 - Active linearization and temperaturecompensation

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Distance and Position Sensors

Distance and Position Sensors Distance and Position Sensors SENSORS FOR DISTANCE AND POSITION Using various measuring techniques, HYDAC offers different distance and position sensors for a wide array of mobile and stationary applications.

More information

Operating Instruction

Operating Instruction Level and Pressure Operating Instruction VEGASWING 71 A Contents Contents Safety information... 2 1 Product description 1.1 Function and configuration... 3 1.2 Functional principle... 3 1.3 Technical data...

More information

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

VEL05 Series. xxx Series. 5 Watt.   AC-DC Power Supplies. Models & Ratings. Input 5 Watt xxx Series Energy Efficiency Level VI Barrel Jack & USB Versions Fixed Mains Connectors Universal Input Output Voltages from 5.0 V to 12.0 V Class II Construction Low Cost BRAND The VEL05 series

More information

CCD1100S. Technical Data Sheet

CCD1100S. Technical Data Sheet CCD00S Technical Data Sheet CCD00S Compact Controller with Display 4 Buttons 3.2 colour TFT 38 configurable I/O Programmable via Guitu Designed f operation at both 2V DC and 24V DC Real Time Clock CCD00S

More information

Desk Panel DPF. Data sheet LINAK.COM/DESKLINE

Desk Panel DPF. Data sheet LINAK.COM/DESKLINE \ Desk Panel DPF Data sheet LINAK.COM/DESKLINE DPF The DPF desk panel is a perfect choice for a wide range of desks and workstations with a demand for either just up and down drive or up, down and memory.

More information

BF series Paddle controllers

BF series Paddle controllers A BF series The BF Series Paddle is the very latest generation in high precision contactless controls. It combines the features of a contactless single axis joystick and a switch in one control. Long trouble-free

More information

Temposonics. Magnetostrictive Linear Position Sensors. EE Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EE Analog Data Sheet Temposonics Magnetostrictive Linear Position Sensors EE Analog Pressure-resistant sensor rod Compact sensor housing High operating temperature MEASURING TECHNOLOGY For position measurement, the absolute,

More information

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview 59in.lbs Smart Electric Valve Actuator Feature rich multi-voltage smart electric actuator with LED status light and function conversion kits. JC-S5 +DPS +BSR Overview The JC-S5 multi-voltage smart electric

More information

Absolute encoders - bus interfaces Solid shaft with clamping or synchro flange Magnetic single- or multiturn encoders 14 bit ST / 18 bit MT

Absolute encoders - bus interfaces Solid shaft with clamping or synchro flange Magnetic single- or multiturn encoders 14 bit ST / 18 bit MT Features Encoder single- or multiturn / CANopen Precise magnetic sensing Angular accuracy up to ±0.15 Additional incremental signals High protection up to IP 67 High resistance to shock and vibrations

More information

C5 Series Stainless Steel Photoelectric

C5 Series Stainless Steel Photoelectric C5 Series Stainless Steel Photoelectric Part Number Sensing Range M5 (5 mm) stainless steel - DC 14 models available Diffuse and through-beam styles Long operating distances Compact stainless steel housing

More information

Inclination sensors 1-dimensional, measuring range

Inclination sensors 1-dimensional, measuring range Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R

More information

IELR Series

IELR Series IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic

More information

Analog micro push button

Analog micro push button Analog micro push button for rugged applications 145MA... + 0.5...4.5 V DC analog output at 5 ± 0.5 V DC operating voltage + output signal can be adjusted within the voltage range + non-contact operation

More information

Absolute encoders - bus interfaces Encoder kit Magnetic single- or multiturn encoders 14 bit ST / 18 bit MT

Absolute encoders - bus interfaces Encoder kit Magnetic single- or multiturn encoders 14 bit ST / 18 bit MT Magnetic single- or multiturn encoders 1 bit ST / 18 bit MT Features single- or multiturn / CANopen Precise magnetic sensing Angular accuracy up to ±0.1 Additional incremental signals High protection up

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up

More information

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB,

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB, Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB, 03.09.2012 OPUS A3 Standard Basic Landscape OPUS A3 Standard Basic Landscape/Portrait 1 Order Numbers OPUS A3 STANDARD Basic Wachendorff Projektor

More information

RTU500 series Data Sheet Power Supply CP-E 24/2.5

RTU500 series Data Sheet Power Supply CP-E 24/2.5 Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped

More information

TECH system Water Valve Control Unit

TECH system Water Valve Control Unit TECH system Water Valve Control Unit WCU with 1 actuator Installation manual Voltage supply 230V AC IMPORTANT! Follow the guidelines in this instruction manual before commissioning the system. Important

More information

Draw wire sensors, draw wire sensors for displacement, position

Draw wire sensors, draw wire sensors for displacement, position Draw wire sensors, draw wire sensors for displacement, position Sensors based on potentiometer and encoder, for industrial and OEM applications for measurement of lengths, stroke, displacement, position,

More information

Incremental Encoder with Hollow Shaft

Incremental Encoder with Hollow Shaft Incremental Encoder Type RI 36-H n miniature industry encoder for high number of pulses n short mounting length n easy mounting procedure n Application e.g.: - Motors - Machine tools - Packaging Machines

More information

Technical Data Sheet OPUS A6 ECO Full TDS OPUS A6eF,

Technical Data Sheet OPUS A6 ECO Full TDS OPUS A6eF, Technical Data Sheet OPUS A6 ECO Full TDS OPUS A6eF, 02.10.2012 OPUS A6 ECO Full Landscape 1 Order Numbers OPUS A6 ECO Full Wachendorff Projektor Landscape CoDeSys Landscape ISO-VT Landscape 2 Mechanical

More information

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

ED-21 Analog Output Series Magnetic Encoder

ED-21 Analog Output Series Magnetic Encoder Analog voltage or current output Low profile IP52 sealing Ball bearing Custom housings, shafts, connectors available, in most cases with no additional tooling required DESCRIPTION The ED-21 series magnetic

More information

Technical Data Sheet OPUS A3 STANDARD Full

Technical Data Sheet OPUS A3 STANDARD Full Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF, 20.02.2015 OPUS A3 Standard Full 1 Order Numbers OPUS A3 STANDARD Full Wachendorff Elektronik Wachendorff Projektor Landscape Landscape/Portrait

More information

Inclination sensors 2-dimensional, measuring range up to ±90

Inclination sensors 2-dimensional, measuring range up to ±90 Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R

More information

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview Feature rich multi-voltage smart electric actuator with LED status light and function conversion kits. JC-S5 +DPS Overview The JC-S5 multi-voltage smart electric valve actuator offers an impressive list

More information

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner GB Product Data Sheet 99.70.06-B AVM321S/AVM322S: 1000N Actuator with analog SUT positioner Areas of use For actuation of 2- and 3-way valves. For controllers with constant output (0...10 V / 4...20 ma)

More information

ACS HEAVY DUTY INCLINOMETER SAE J1939 INTERFACE

ACS HEAVY DUTY INCLINOMETER SAE J1939 INTERFACE ACS HEAVY DUTY INCLINOMETER ACS Heavy Duty inclinometers from POSITAL are robust inclination sensors specially designed for applications involving rough handling and exposure to rigorous conditions. The

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB,

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB, Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB, 26.08.2013 OPUS A3 Standard Basic Landscape OPUS A3 Standard Basic Landscape/Portrait 1 Order Numbers OPUS A3 STANDARD Basic Wachendorff Projektor

More information

Datasheet - CSS 11-30S-D-M-ST

Datasheet - CSS 11-30S-D-M-ST 12.02.2013-18:42:30h Datasheet - CSS 11-30S-D-M-ST Safety sensors / CSS 30S Preferred typ Stainless steel enclosure Max. 31 sensors can be wired in series. Connector M12, 8-pole Ø M30 High repeat accuracy

More information

Datasheet - RSS 36-D-R-ST

Datasheet - RSS 36-D-R-ST 14.03.2018-19:30:37h Datasheet - RSS 36-D-R-ST Safety sensors / RSS 36 Thermoplastic enclosure RFID-technology for needs-based protection against tampering Misaligned actuation possible 27 mm x 108.2 mm

More information

NOVOHALL Rotary Sensor touchless transmissiv. Series RFC4800 SSI, SPI, Incremental

NOVOHALL Rotary Sensor touchless transmissiv. Series RFC4800 SSI, SPI, Incremental NOVOHALL Rotary Sensor touchless transmissiv Series RFC4800 SSI, SPI, Incremental The sensor utilizes the orientation of a magnetic field for the determination of the actual position. Therefore, a magnet

More information

RS485 (S85- -Y13) Display (S85- -Y13) Setting push-buttons (S85- -Y03) Power supply Vdc 24 V +/- 20% PNP NPN Output Push pull

RS485 (S85- -Y13) Display (S85- -Y13) Setting push-buttons (S85- -Y03) Power supply Vdc 24 V +/- 20% PNP NPN Output Push pull LASER distance sensor for precise measurement up to 20 m with a millimeter of resolution and repeatability through the Time of Flight technique Time of Flight technology Class 2 visible red LASER for an

More information

High Precision Quad Output DC Power Supply

High Precision Quad Output DC Power Supply User's Guide High Precision Quad Output DC Power Supply Model 382270 Introduction Thank you for selecting the Extech Model 382270. This device is shipped fully tested and calibrated and, with proper use,

More information

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Level sensor Stainless steel version Model RLT-1000, for industrial applications Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring

More information

IELR Rail-Mount Series Magnetic Circuit Protectors

IELR Rail-Mount Series Magnetic Circuit Protectors IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series

More information