Machine Layout Basics

Size: px
Start display at page:

Download "Machine Layout Basics"

Transcription

1 QUICK REFERENCE GUIDE KI7347C Series Optical Two Way Loss Test Set with ORL Machine Layout Basics Save Test Data Power Hard Key Functions Wavelength Tested Light Source ORL Meter Power Meter Auto Test Measurement Toggle Buttons Battery Compartment Latch

2 Layout Basics Continued Screen Cover Save Test Data Memory Recall Toggle Test Results Hard Key Functions Hidden Key Pad Power Exit Backlight Set Light Source ORL Meter Bi-Directional Test Port Power Meter 2

3 Layout Basics Continued Interchangeable Mating Sleeve Interchangeable Mating Sleeve Mating Sleeve Release Mating Sleeve Release Mating Sleeve in Closed Position Provides protection for sleeve and connector Mating Sleeve in Pivot Position Easy access for cleaning, inspecting and changing adapters 3

4 Reference Procedures Loopback Reference Procedure for Two Way Measurements NOTE: Light Source/Two Way/ ORL port must use a connector with APC polish NOTE: For two or one direction testing involving two instruments, referencing should be independently performed on both Loss Test Sets. The following will set reference at all wavelengths: Clean and inspect patch cables and testing ports before connecting any cables. Connect the Light Source /Two Way /ORL port to the Power Meter port of the same instrument using the proper patch cable. Select [POWER], Press [Autotest], then press [Abs/Rel] and then press [Set Ref] for 3 seconds. Meters will display BUSY and then 0.00 db R. Loopback Reference Side By Side Reference for Two Way Testing Referencing is performed on one of the instruments, which will set reference at all wavelengths on both Loss Test Sets: Connect the Light Source /Two Way /ORL ports of the instruments. Select [POWER], [Autotest] ], [Abs/Rel] and press [Set Ref] for 3 seconds. Meters will display BUSY and then 0.00 db R. Side by Side Reference for Two Way Testing 4

5 Reference Procedures Continued Side by Side Reference for Single Direction Testing Connect the Light Source/Two Way/ORL port to the power meter of the second instrument. Select [POWER] on both instruments On Light source, Press [Auto test] On Power meter, press [Abs/Rel] and [Set Ref] for 3 seconds. Meter will briefly display BUSY and then 0.00 db R. NOTE: Two patch cables can be used for the reference if required for current testing application. Side By Side Reference for Single Direction Testing Measurement Procedures TWO WAY LOSS AND ORL IN AUTOTEST This method requires a matched pair of Two Way Loss Test Sets, which will perform automated bidirectional testing and wavelength detection by data exchange between the instruments. After Two Way Loss Test Sets have been referenced: Exit Autotest on both instruments. Connect the Fiber Under Test (FUT) to the patch cables connected to the Two Way ports Press [Autotest] on one of the instruments Both instruments now show the same two way average loss in db R and display rotates through all available source wavelengths. 5

6 Two Way Test Measurements Continued Both units also display A B. A will be flashing on the unit where Autotest was initiated, and it has become the A unit. The other unit will flash B, and it has become the B unit. This only indicated which unit is A and B not the direction of test results being displayed. To step through all measurements on locked wavelength, press [ ] button on the hidden keypad. Results are displayed in this order: average bi-directional loss loss from A to B: A B loss from B to A: A B ORL at A end ORL at B end When displaying loss in one direction, the reference value will be shown on the left. Alternatively, selecting [Abs / Rel] displays the actual measured dbm value and source nominal output power. To determine what direction the test result is being displayed in look for the change between the A and B icons when you press the [ ] on the hidden key pad. ORL measurement from A to B ORL measurement from B to A IL measurement average A to B and B to A IL measurement one direction B to A Reference Shown - Indicates 1 direction measurement 6

7 One Way Test Measurements ONE WAY LOSS IN AUTOTEST This method is applicable for loss measurements where data communication is one way only. Testing on one fiber can be achieved with: Single Two Way Loss Test Set Two instruments used as a combination of Light source and Power meter Perform Side by Side Reference for single direction testing. Two patch cables may be used if required for testing application. Connect to the Fiber Under Test (FUT), loss will be automatically displayed. Use [-/+] to show one wavelength only. To exit Autotest, remove test lead for more than 8 seconds or turn off source Memory Functions Data can be stored in all modes, however, memory recall and cancel functions are not available in Autotest and only work in Light Source, Power Meter or Return Loss modes. Clear all memory: press both [MR] and [Exit] simultaneously for 3 seconds. clr will display. To save in next available location, press [M+]. To change next store location, press [ ] [-/+] [Set] or [Menu]. To recall, press [MR] and [-/+] to scroll memory. Use [Abs / Rel] to see db/dbm values. Hold down [Abs/ Rel] to see reference level. For data recorded in Autotest, press [-/+] to view measurements at all source wavelengths. For each wavelength, to step through all available Two Way Loss and ORL Autotest measurements, select [MR], [-/+] and then press [ ] repeatedly. Two way test only: press [ ] repeatedly to scroll details. To exit memory display, press [Menu]. 7

8 Transferring Saved Data Data transfer between the KI 7347 and Kits external software package must be completed using the USB to RS 232 cable. Install KITS software from CD provided with the Test Set or go to Once KITS program has been loaded on the computer open the program. KITS program will display the welcome screen with option for setting up the report. Note that several report options are available. For Bi- Directional Testing we will select Loss Testing and Meter Dump. Uncheck all other worksheets. Uncheck Data Logging and Meter Reading Select Setup to additional reporting criteria which must be determined. If unit is not connected to the computer this screen will appear. Connect the meter to the computer using the USB to RS 232 cable and press Connect. Once unit has been connected press Setup to continue with report setup. 8

9 This menu will allow you to select the parameters for testing as well as the report build. Be sure to confirm your Test Directions are set properly including ORL Tests at A and B locations. Otherwise this data will not be transferred. Reference End may be different depending on the reference style chosen. Confirm Wavelength for both Source and Test the press the Green Arrow. Complete the necessary data including connector type, cable length ( be sure to convert to feet or miles), splices and connectors. Confirm the number of fibers to test including what fiber to start at. This example is fiber 19. Pass/Fail standards can be compared against International or Custom. Example has established custom standards. 9

10 Now the computer should display the Live Data Worksheet without test results. To import results from the meter select Add-ins to access the KITS menu. Next Select Test Data and then Memory Download to start loading results from the machine. Once activating the memory download be sure to indicate where to start memory download from, how many results or fibers to be downloaded, wavelengths to be downloaded and what fiber ID to start at. This example has fiber 19 saved in the memory as 19. Which makes both circled values identical. 10

11 The Final Report Final report will populate with the values downloaded from the machine. This example shows failing results based on the Pass/Fail criteria the user established in previous menus. In this case Insertion Loss was excessive on all fibers at 1310 and one fiber/wavelength failed the ORL test. Certain items such as Statistical Analysis can be hidden to make the report smaller. Consult the KITS user manual for more functionality specifics Limberlost Rd Clinton NY

FX40/45 Series Manual D P RevA00 Page 1 of 25. FX40/45 Series Manual D P RevA00 Page 1 of 25

FX40/45 Series Manual D P RevA00 Page 1 of 25. FX40/45 Series Manual D P RevA00 Page 1 of 25 FX40/45 Series Manual D07-00-101P RevA00 Page 1 of 25 FX40/45 Series Manual D07-00-101P RevA00 Page 1 of 25 USER MANUAL FX40/45 Series Please direct all questions to your local VeEX Sales Office, Representative,

More information

OLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide OLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide Warranty All NOYES test equipment products are warranted for a period of (1) one year from the

More information

OFL250 OTDR. Quick Reference Guide. or +1 (800) , +1 (603)

OFL250 OTDR. Quick Reference Guide.  or +1 (800) , +1 (603) OFL250 OTDR Quick Reference Guide www.aflglobal.com or +1 (800) 321-5298, +1 (603) 528-7780 Functional Keys Functional Keys KEY NAME KEY FUNCTION Power Press and hold (approx. 2 sec.) to turn the OFL250

More information

OTR 500 OTDR USER S MANUAL

OTR 500 OTDR USER S MANUAL OTR 500 OTDR USER S MANUAL Avoid exposure. Laser radiation emitted from the aperture. This product conforms to CDRH standards for laser product Per 21 CFR 1040.10 & 1040.11 1 SECTION Table of Contents

More information

Training Training Manual: Manual: KI9800A Series Pocket Fibre Sources Level 1

Training Training Manual: Manual: KI9800A Series Pocket Fibre Sources Level 1 June 2011 Training Manual: KI9800A Series Pocket Fibre s Level 1 Course Contents 1. Typical Applications 2. General Features 3. Models 4. Keypad 5. Instrument care 6. Operation 7. Operating Modes 8. Additional

More information

MT9085 Series. ACCESS Master. Quick User s Guide

MT9085 Series. ACCESS Master. Quick User s Guide Quick User s Guide MT9085 Series ACCESS Master For safety and warning information, please read this manual before attempting to use the equipment. Keep this manual with the equipment. MT9085 Series ACCESS

More information

OTDR Testing Quick Reference Guide

OTDR Testing Quick Reference Guide Keys OTDR Testing Quick Reference Guide Key Name Key Function Power Press and hold (approx. 1 sec.) to turn the OTDR on or off or VFL Menu L and R Tab keys Arrow keys Enter Back Test Save ON 2 Hz - Press

More information

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Limited Warranty All NOYES test equipment products

More information

CS260 Contractor Series OTDR

CS260 Contractor Series OTDR CS260 Contractor Series OTDR Quick Reference Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Functional Keys KEY NAME KEY FUNCTION Power Press and hold (~1 second) to turn the CS260 on or off.

More information

OFT-CWDM SERIES. Operation Guide. Optical Time Domain Reflectometer (OTDR) with CWDM Wavelengths V

OFT-CWDM SERIES. Operation Guide. Optical Time Domain Reflectometer (OTDR) with CWDM Wavelengths V OFT-CWDM SERIES Optical Time Domain Reflectometer (OTDR) with CWDM Wavelengths V.9.12.17 Operation Guide 1.0 OTDR Quick Start Guide Press to turn on the OTDR. Connect the fiber to the appropriate port.

More information

Thunder Bolt Multi-Tester Operations Manual

Thunder Bolt Multi-Tester Operations Manual Thunder Bolt Multi-Tester Operations Manual TABLE OF CONTENTS Thunder Bolt Multi-Tester Universal Features and Settings... 1 Thunder Bolt Application Operation... 2 Trace View Pane... 2 Cursor Marker

More information

OFT-3 Optical Time Domain Reflectometer User's Guide

OFT-3 Optical Time Domain Reflectometer User's Guide OFT-3 Optical Time Domain Reflectometer User's Guide Revision A 02/2014 Information contained in this manual is believed to be accurate and reliable. However, no responsibility is assumed by Precision

More information

Optical CWDM Power Meter

Optical CWDM Power Meter User Manual Optical CWDM Power Meter TheFibers Inc. A-1109 Keumkang Penterium IT Tower, 282 Hagui-ro, Dongan-gu, Anyang-City, Korea Tel: +82-31-381-6108 Fax: +82-31-381-6109 Email: sales@thefibers.com

More information

KI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter

KI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter User Manual KI6503 series 48-Channel Optical DWDM Power Meter Warranty: Information in this manual is given in good faith for the benefit of the user. It cannot be used as the basis for claims against

More information

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter User Manual KI6501 series Optical CWDM Power Meter Warranty: Information in this manual is given in good faith for the benefit of the user. It cannot be used as the basis for claims against Kingfisher

More information

Model RP450. Optical Power Meter

Model RP450. Optical Power Meter Model RP450 Optical Power Meter 143 Lake St, Laconia, NH USA 03246 603-524-8350 Fax - 603-524-8332 www.odm-inc.com RP450 REV C 1-28-11 Specifications subject to change without notice Contents Introduction

More information

FTE-7500 OTDR USER S MANUAL

FTE-7500 OTDR USER S MANUAL FTE-7500 OTDR USER S MANUAL 8/29/2011 Avoid exposure Laser Radiation Emitted from the aperture. This product conforms to CDRH standards for laser product Per 21 CFR 1040.10 & 1040.11 Revision B SECTION

More information

FlexScan OTDR With SmartAuto and LinkMap

FlexScan OTDR With SmartAuto and LinkMap Test & Inspection FlexScan OTDR With SmartAuto and LinkMap Quick Reference Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Controls, Display, Interfaces 1 2 4 8 1. Power button 2. Power jack

More information

OVR Optical Time Domain Reflectometer User's Guide

OVR Optical Time Domain Reflectometer User's Guide OVR Optical Time Domain Reflectometer User's Guide This guide is written for use with the OVR series. This includes the standard OVR OTDRs, OVR-PON and OVR-CWDM Revision D 04/2016 Information contained

More information

OTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities

OTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities features and benefits Large LCD screen and soft key menus Source and meter in one unit Auto wavelength switching and detection USB data ports OTS-600 Series Light Source and Power Meter Photo LAN1193 Ease

More information

Certification Testing Quick Reference Guide

Certification Testing Quick Reference Guide Keys Certification Testing Quick Reference Guide Key Name Key Function Power Press and hold (approx. 1 sec.) to turn the OTDR on or off VFL Menu ON 2Hz - Press and hold (approx. 2 sec.) LED will flash

More information

PM-204A/B. Power Meter. Operation Guide

PM-204A/B. Power Meter. Operation Guide Power Meter Operation Guide Contents 1. Introduction...3 2. Warranty...3 3. Safety Information...3 4. Preparing for Operation...4 4.1. Unpacking the instrument...4 4.2. Discharged batteries...4 4.3. AC

More information

VIAVI SmartClass OLA-55M

VIAVI SmartClass OLA-55M Data Sheet VIAVI SmartClass OLA-55M Optical Level Attenuator VIAVI Solutions VIAVI SmartClass optical handhelds go beyond the basics With more than 100,000 optical handhelds already in use, VIAVI continues

More information

User Manual. Optical DWDM Power Meter ODPM-48

User Manual. Optical DWDM Power Meter ODPM-48 User Manual Optical DWDM Power Meter TheFibers Inc. A-1109 Keumkang Penterium IT Tower, 282 Hagui-ro, Dongan-gu, Anyang-City, Korea Tel: +82-31-381-6108 Fax: +82-31-381-6109 Email: sales@thefibers.com

More information

FTE-8000 Hand Held Optical Spectrum Analyzer

FTE-8000 Hand Held Optical Spectrum Analyzer FTE-8000 Hand Held Optical Spectrum Analyzer USER S MANUAL Table of Contents SECTION PAGE 1.0 Safety........... 1 2.0 FTE-8000 Quick Start...... 2 3.0 Introduction.....3 4.0 Preparation for Use... 4 Inspection

More information

VIAVI. OLA-54 and OLA-55. SmartClass. Data Sheet. Optical Level Attenuator. VIAVI SmartClass optical handhelds go beyond the basics.

VIAVI. OLA-54 and OLA-55. SmartClass. Data Sheet. Optical Level Attenuator. VIAVI SmartClass optical handhelds go beyond the basics. Data Sheet VIAVI TM SmartClass Optical Level Attenuator OLA-54 and OLA-55 VIAVI Solutions VIAVI SmartClass optical handhelds go beyond the basics With more than 100,000 optical handhelds already in use,

More information

FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide

FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide Test & Inspection FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Table of Contents Safety Information....3 How to View Device

More information

Advanced Test Equipment Rentals ATEC (2832) OMNIScanner TM. featuring OMNIFiber TM

Advanced Test Equipment Rentals ATEC (2832) OMNIScanner TM. featuring OMNIFiber TM Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMNIScanner TM featuring OMNIFiber TM the future of network testing OMNIScanner2 TM OMNIScanner LT TM OMNIFiber TM User

More information

FlexScan FS200 OTDR With SmartAuto, FleXpress and LinkMap Quick Reference Guide

FlexScan FS200 OTDR With SmartAuto, FleXpress and LinkMap Quick Reference Guide Test & Inspection FlexScan FS200 OTDR With SmartAuto, FleXpress and LinkMap Quick Reference Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Controls, Display, Interfaces 1 2 4 8 1. Power button

More information

C2000 POWER METER With Data Storage

C2000 POWER METER With Data Storage C2000 POWER METER With Data Storage Operation Instructions CONTENT 1. Features 2. Functions 3. Operation 4. Specification 2 1. Features The Appointech C2000 handheld power meter has calibrated readings

More information

KI 2600 Series Hand Held Fiber Meter KI 2400/KI 2800 Series Hand Held Fiber Source KI 2300/KI 2700 Series Hand Held Loss Test Meter

KI 2600 Series Hand Held Fiber Meter KI 2400/KI 2800 Series Hand Held Fiber Source KI 2300/KI 2700 Series Hand Held Loss Test Meter KI 2600 Series Hand Held Fiber Meter KI 2400/KI 2800 Series Hand Held Fiber Source KI 2300/KI 2700 Series Hand Held Loss Test Meter OPERATION AND MAINTENANCE GUIDE Manufacturer s Name: Manufacturer s Address:

More information

FlexScan OTDR With SmartAuto and LinkMap

FlexScan OTDR With SmartAuto and LinkMap FlexScan OTDR With SmartAuto and LinkMap User s Guide Test & Inspection Contents Safety Information...5 Hardware Overview...7 Controls, Display, Interfaces...7 Front Panel Buttons and Indicators...9 Battery

More information

Test & Inspection. FOCIS Duel. Fiber Optic Connector Inspection System Quick Reference Guide. or (800) , (603)

Test & Inspection. FOCIS Duel. Fiber Optic Connector Inspection System Quick Reference Guide.   or (800) , (603) Test & Inspection FOCIS Duel Fiber Optic Connector Inspection System Quick Reference Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Controls, Display, Interfaces 1 Power key - 2 Image Capture

More information

POL-001 Fiber-Optic In-Line Polarizer. Operation Manual

POL-001 Fiber-Optic In-Line Polarizer. Operation Manual POL-001 Fiber-Optic In-Line Polarizer Operation Manual Feb. 18, 2002 General Photonics Corp. Ph: (909) 590-5473 5228 Edison Ave. Fax: (909) 902-5536 Chino, CA 91710 USA www.generalphotonics.com Document

More information

KI 2400/2800 SERIES HAND HELD FIBER SOURCE FEATURES. kingfisher.com.au. OPTICAL COMMUNICATIONS TEST APPLICATIONS (in combination with a power meter)

KI 2400/2800 SERIES HAND HELD FIBER SOURCE FEATURES. kingfisher.com.au. OPTICAL COMMUNICATIONS TEST APPLICATIONS (in combination with a power meter) OPTICAL COMMUNICATIONS TEST APPLICATIONS (in combination with a power meter) Mixed single mode & multimode loss testing to 6 λ Multi-Fiber continuity & polarity testing Encircled Flux compliant testing

More information

OTS-400 Series Optical Meters, Sources and Testers A LANscape Solutions Product

OTS-400 Series Optical Meters, Sources and Testers A LANscape Solutions Product OTSK-4MDSD Specs Provided by www.aaatesters.com OTS-400 Series Applications Installation, testing and troubleshooting of LAN, telco, CATV and FTTx networks Description The OTS-400 Series of intelligent

More information

MAP Insertion Loss/Return Loss Meter (morl-a1 with PCT Automation Software)

MAP Insertion Loss/Return Loss Meter (morl-a1 with PCT Automation Software) COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS MAP Insertion Loss/Return Loss Meter (morl-a1 with PCT Automation Software) Key Features Mandrel-free optical return loss measurements on fiber-optic patch-cords

More information

920XC Training. 920XC Handheld OTDR. Training Presentation VER 1.0

920XC Training. 920XC Handheld OTDR. Training Presentation VER 1.0 920XC Training XC fibertools 920XC Handheld OTDR Training Presentation VER 1.0 OTDR Basic Operation Laser End of fiber Probe pulse Display Processor Coupler Detector Fiber under test Rayleigh backscatter

More information

SmartClass TM Fiber FBP-HD4i/HD4iP and OLP-82/82P

SmartClass TM Fiber FBP-HD4i/HD4iP and OLP-82/82P SmartClass TM Fiber FBP-HD4i/HD4iP and OLP-82/82P Inspect, test, certify, and save with one device QUICK START GUIDE 22002195 REV 0 REV 0 Notice Copyright Trademarks Every effort was made to ensure that

More information

PPM-30 PON Power Meter. User s Manual. Shineway Technologies, Inc. All rights reserved.

PPM-30 PON Power Meter. User s Manual. Shineway Technologies, Inc. All rights reserved. PPM-30 PON Power Meter User s Manual Shineway Technologies, Inc. All rights reserved. PPM-30 PON Power Meter Safety Instructions Safety Terms Used in This Manual WARNING identifies any procedure or practice

More information

Operation Manual for OPM-1315 Optical Power Meter

Operation Manual for OPM-1315 Optical Power Meter Operation Manual for OPM-1315 Optical Power Meter www.tonercable.com Table of Contents 1. Introduction... 1,2 1.1 Summary... 1 1.2 Product Features... 2 1.3 Technical Parameters... 2 1.4 Main Applications...

More information

Optical Power Meter MT-7603

Optical Power Meter MT-7603 Optical Power Meter English USER'S GUIDE Optical Power Meter English WARNING You are cautioned that changes or modifications not espressly approved in this document could void yout authority to operate

More information

PM-100 SERIES. Operation Guide. Power Meter V

PM-100 SERIES. Operation Guide. Power Meter V PM-100 SERIES Power Meter Operation Guide V5.27.16 Contents 1 Introduction...2 2 Warranty...2 3 Safety Information...3 4 Preparing for Operation...3 4.1 Unpacking the instrument...3 4.2 Discharged batteries...3

More information

FIBER. WP-TEST-FIBER-400 Optical Power Meter Owner s Manual

FIBER. WP-TEST-FIBER-400 Optical Power Meter Owner s Manual FIBER WP-TEST-FIBER-400 Optical Power Meter Owner s Manual Technical Support: p. 866.838.5052 2017 Wirepath Ver. 170419-1000 Contents Chapter 1. Standard Configuration... 2 Chapter 2. Overview... 2 Chapter

More information

FTE-8000-DWDM Optical Spectrum Analyzer and FTE-8000-CWDM Channel Analyzer Users Guide

FTE-8000-DWDM Optical Spectrum Analyzer and FTE-8000-CWDM Channel Analyzer Users Guide FTE-8000-DWDM Optical Spectrum Analyzer and FTE-8000-CWDM Channel Analyzer Users Guide Revision D 3/2012 TTI makes every effort to insure all statements and information for the products referred to in

More information

Electronic Indicator

Electronic Indicator TIR ABS CR /MM Electronic Indicator Operating Manual Analog Display Analog Visual Display Incremental Measuring Mode SPC Cables USB, MTI, RS232 Measuring System in English or Metric Travel Reverse Auto

More information

OTS-400 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities A LANscape Solutions Product

OTS-400 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities A LANscape Solutions Product Applications Testing and troubleshooting of various telecommunication networks Description The Corning Cable Systems OTS-400 Series of intelligent and versatile optical meters, sources and testers offers

More information

PM-212-SI3 Pocket Optical Power Meter INSTRUCTION MANUAL

PM-212-SI3 Pocket Optical Power Meter INSTRUCTION MANUAL PM-212-SI3 Pocket Optical Power Meter INSTRUCTION MANUAL Revision 2.4 is the registered trademark of OPTOKON, a.s. Other names and trademarks mentioned herein may be the trademarks of their respective

More information

Handheld Optical Power Meter. Model SSF-TKITP-400 OPTICAL POWER METER. Manual

Handheld Optical Power Meter. Model SSF-TKITP-400 OPTICAL POWER METER. Manual Model SSF-TKITP-400 OPTICAL POWER METER Manual August 2016 Contents Chapter 1. Standard Configuration.....2 Chapter 2. Overview...........2 Chapter 3. Data Sheet.....3 Chapter 4. Function.........4 4.1

More information

WIREXPERT FIBER LOSS TEST KIT TECHNICAL REFERENCE MANUAL. WireXpert Fiber Loss Test Kit Technical Reference Manual

WIREXPERT FIBER LOSS TEST KIT TECHNICAL REFERENCE MANUAL. WireXpert Fiber Loss Test Kit Technical Reference Manual WireXpert Fiber Loss Test Kit Technical Reference Manual i Table of Contents Introduction... 1 Package Contents... 1 Single-mode Certification Kit... 1 Multi-mode Certification Kit... 1 Features and Benefits...

More information

Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved.

Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved. TC500 Ethernet Cabling Certifier Operation Manual Version 1.13 Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved. Warranty This instrument is guaranteed for a period of 2 years

More information

T0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE

T0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE T0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE INDEX 1. Interfaces and Controls...1 2. Power On...2 3. Setup...2 3.1 To set the UNIT...3 3.2 To set the LAN Length Adjustment...3 3.3 To set the COAX Length

More information

GUPM100 USB Optical Power Meter Function and Specifications

GUPM100 USB Optical Power Meter Function and Specifications 1 GUPM100 USB Optical Power Meter Function and Specifications 52082469 2 Table of Contents I. Introduction... 3 II. Device Overview... 4 III. Data Manager for Windows... 5 IV. GVIS for Windows... 9 V.

More information

AF-OLK5A Series Fiber Optic Test kit

AF-OLK5A Series Fiber Optic Test kit AF-OLK5A Series Fiber Optic Test kit Description The AF-OLK5A series test kits are the complete solution necessary for the installer to test, terminate and trouble shoot fiber optic systems. These test

More information

TC41-Thermocouple Thermometers User Manual

TC41-Thermocouple Thermometers User Manual TC41-Thermocouple Thermometers User Manual Product Registration cs@perfect-prime.com Product Introduction This thermometer can be used to measure up to 4 different temperatures simultaneously, and with

More information

Datasheet: Fiber OneShot PRO Singlemode Fiber Distance and Fault Locator; Fiber QuickMap Multimode Fiber Distance and Fault Locator

Datasheet: Fiber OneShot PRO Singlemode Fiber Distance and Fault Locator; Fiber QuickMap Multimode Fiber Distance and Fault Locator Datasheet: Fiber OneShot PRO Singlemode Fiber Distance and Fault Locator; Fiber QuickMap Multimode Fiber Distance and Fault Locator Datasheet: Fiber OneShot PRO Singlemode Fiber Distance and Fault Locator;

More information

OLS-55/56 Sm a r t Optical Laser Source A Sm a r t, Future-Proof Optical Laser Source

OLS-55/56 Sm a r t Optical Laser Source A Sm a r t, Future-Proof Optical Laser Source COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS /56 Sm a r t Optical Laser Source A Sm a r t, Future-Proof Optical Laser Source Key features New Laser source with up to four wavelengths offers flexibility

More information

Data Manager Software User Manual

Data Manager Software User Manual Data Manager Software User Manual CONTENTS 1. Installation of USB Virtual COM Port driver software... 2 2. Installation of Data Manager Software... 2 3. Connecting instrument to a PC (Personal Computer)...

More information

Optical Power Meter. TrendCommunications. User Guide Testing the World s Networks

Optical Power Meter. TrendCommunications. User Guide Testing the World s Networks Optical Power Meter User Guide - 137800 Testing the World s Networks TrendCommunications Copyright Notice The information contained in this document is the property of Trend Communications Ltd. and is

More information

OLTS-85 SmartClass Fiber. User s Guide BN 2325/ English

OLTS-85 SmartClass Fiber. User s Guide BN 2325/ English OLTS-85 SmartClass Fiber User s Guide BN 2325/98.21 2016.01 English Please direct all inquiries to your local Viavi sales company. The addresses can be found at: www.viavisolutions.com/en-us/contact-sales-expert

More information

Installation and Operation Manual Model 9A02 Software Version 2.0

Installation and Operation Manual Model 9A02 Software Version 2.0 Installation and Operation Manual Model 9A02 Software Version 2.0 AccessPCHT Installation and Operation Welcome to the AccessPCHT installation and operation guide. This guide will help you install and

More information

M-Series OTDRs. User s Guide. (800) or (603)

M-Series OTDRs. User s Guide.  (800) or (603) M-Series OTDRs User s Guide www.aflglobal.com/go/noyes, (800) 321-5298 or (603) 528-7780 Limited Warranty All NOYES test equipment products are warranted for a period of (1) one year from the date of delivery

More information

Axxis Biometrics LLC. BioAxxis L113 Fingerprint Door Lock Programming Kit

Axxis Biometrics LLC. BioAxxis L113 Fingerprint Door Lock Programming Kit Axxis Biometrics LLC BioAxxis L113 Fingerprint Door Lock Programming Kit Revision 0.14 Dec 2005 Table of Contents 1. Introduction... 2 Product Overview... 2 Main Features... 2 Packing Lists... 3 2. Operation

More information

OLT-55. Intelligent Optical Loss Tester. User s Manual

OLT-55. Intelligent Optical Loss Tester. User s Manual OLT- Intelligent Optical Loss Tester User s Manual Shineway Technologies, Inc. All rights reserved. Safety Instructions Safety Terms Used in This Manual The WARNING sign denotes a hazard. It calls attention

More information

TFS-3200 Series Optical Spectrum Analyzers

TFS-3200 Series Optical Spectrum Analyzers TFS-3200 Series Optical Spectrum Analyzers TFS-3200C - C-Band (1530 to 1561 nm) TFS-3200S - S-Band (1574 to 1608 nm) TFS-3200L - L-Band (1460 to 1530 nm) Operation Manual Trilithic Company Profile Trilithic

More information

FTE-6000 Hand Held Tuneable Laser Source

FTE-6000 Hand Held Tuneable Laser Source FTE-6000 Hand Held Tuneable Laser Source USER S MANUAL Avoid Exposure Laser Radiation Emitted From The Aperture This product conforms to CDRH standards for laser product Per 21 CFR 1040.10 & 1040.11 Table

More information

SCT-MMA / SCT-SMA Fiber Optic Adapters

SCT-MMA / SCT-SMA Fiber Optic Adapters SCT-MMA / SCT-SMA Fiber Optic Adapters USER MANUAL ENGLISH i SAFETY WARNINGS Read First: Safety and Operational Information The international electrical symbols used on the instrument or in this manual

More information

North America & Canada Softing Inc. Knoxville, Tennessee Tel.: Europe/Middle East/Africa

North America & Canada Softing Inc. Knoxville, Tennessee Tel.: Europe/Middle East/Africa English North America & Canada Softing Inc. Knoxville, Tennessee Tel.: +1.865.251.5252 E-Mail: sales@softing.us Singapore Softing Singapore Pte. Ltd. Singapur Tel.: +65-6569-6019 E-Mail: asia-sales.itnetworks@softing.com

More information

User Manual Fiber Certification Testing

User Manual Fiber Certification Testing User Manual Fiber Certification Testing User Manual Fiber Certification, WireXpert v7.1.0, build #276 WireXpert4500_Fiber_IT_EN_U_201511_102S Copyrights 2015 Softing Inc. http://itnetworks.softing.com/

More information

PM-212-MPO Pocket Optical Power Meter INSTRUCTION MANUAL

PM-212-MPO Pocket Optical Power Meter INSTRUCTION MANUAL PM-212-MPO Pocket Optical Power Meter INSTRUCTION MANUAL Revision 1.2 is the registered trademark of OPTOKON, a.s. Other names and trademarks mentioned herein may be the trademarks of their respective

More information

Product Introduction. G0306A USB 400x Video Inspection Probe

Product Introduction. G0306A USB 400x Video Inspection Probe Product Introduction G0306A USB 400x Video Inspection Probe G0306A USB 400x Video Inspection Probe Product Introduction March 2014 Anritsu Corporation Slide 1 VIP Series Support Products Mainframe MU909014x/15x

More information

Excel 2013 Next Steps

Excel 2013 Next Steps Excel 2013 Next Steps ADULT SERVICES DEPARTMENT CRYSTAL LAKE PUBLIC LIBRARY 126 W. PADDOCK STREET CRYSTAL LAKE, IL 60014 815-459-1687, X7 WWW.CLPL.ORG Agenda 2 Home Toolbar Alignment Group Number Formats

More information

SCT2000 and SCT1500 Structured Cable Testers

SCT2000 and SCT1500 Structured Cable Testers SCT2000 and SCT1500 Structured Cable Testers USER MANUAL ENGLISH 1 SAFETY WARNINGS Read First: Safety and Operational Information The international symbols used on the instrument or in this manual are

More information

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model User Manual Dual-Input Data Logging Thermometers with NIST-Traceable Calibration Thermocouple Meter, Type J/K/T Input Model 20250-92 Thermistor Meter Model 20250-94 RTD Meter Model 20250-96 THE STANDARD

More information

Electronic Indicator

Electronic Indicator IN/MM 2ND TOL Electronic Indicator Operating Manual Non-Analog Digital Display 3 Programmable Presets and 3 Programmable Ratios Extra-Large Number Display Incremental Measuring Mode SPC Cables USB, MTI,

More information

WMC Remote Control and Receiver RRC-127 User Manual

WMC Remote Control and Receiver RRC-127 User Manual Welcome Congratulations on your purchase of the Remote Control and Receiver for Windows Media Center. The infrared (IR) remote control and receiver let you access and manage your Media Center PC and other

More information

Optical Power Meter With VFL. User Manual

Optical Power Meter With VFL. User Manual With VFL User Manual Contents 1. Summary...1 2. Functions...2 3. Specifications...3 4. Layout...4 5. Operation...5 6. Maintenance...9 7. Charge battery...9 8. Faults & Solutions...10 9. Software...10 1

More information

User Manual. Thermocouple Thermometer with Dual Type K/J Inputs and Data Logging. Model with NIST-Traceable Calibration

User Manual. Thermocouple Thermometer with Dual Type K/J Inputs and Data Logging. Model with NIST-Traceable Calibration User Manual Thermocouple Thermometer with Dual Type K/J Inputs and Data Logging with NIST-Traceable Calibration Model 20250-02 THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense Thermocouple

More information

Thermo Scientific Orion Star A223 and Star A323 Portable RDO/DO Meter. Instruction Sheet

Thermo Scientific Orion Star A223 and Star A323 Portable RDO/DO Meter. Instruction Sheet English RDO / DO Thermo Scientific Orion Star A223 and Star A323 Portable RDO/DO Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the appropriate wall socket

More information

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide 2004-2009, AFL Telecommunications, all rights reserved. COM4-00-1001 Revision E, 2009-06-16 Specifications

More information

Polymer Coated Fiber Cable (PCF)

Polymer Coated Fiber Cable (PCF) Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability

More information

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8 15,0,15,0,1,14,1,14,13,2,13,2,3,12,3,12,11,4,11,4,5,10,5,10,9,6,9,6,7,8,7,8 WalkLAB Professional Conductivity-TDS-Salinity Meter HC 9021 Operations Manual 0 INTRODUCTION

More information

GI-4000 User Manual. Kobetron, Inc. P.O. Box 5489 Navarre, FL 32566

GI-4000 User Manual. Kobetron, Inc. P.O. Box 5489 Navarre, FL 32566 GI-4000 User Manual Kobetron, Inc. P.O. Box 5489 Navarre, FL 32566 TEL: (850) 939-5222 FAX: (850) 939-0490 EMAIL: sales@kobetron.com WEB: www.kobetron.com "Testing Tomorrow's Technology Today" TABLE OF

More information

Ra Series Fiber Optic Test Instruments

Ra Series Fiber Optic Test Instruments Ra Series Fiber Optic Test Instruments Ra Series Fiber Optic Test Instruments The Datacom Textron Ra Series are innovative, easy to use instruments for the field-testing, certifying and maintenance of

More information

Professional Thermocouple Thermometer with Four Type K Inputs, Data Logging, and Optional Infrared Wand

Professional Thermocouple Thermometer with Four Type K Inputs, Data Logging, and Optional Infrared Wand User Manual Professional Thermocouple Thermometer with Four Type K Inputs, Data Logging, and Optional Infrared Wand with NIST-Traceable Calibration Model 20250-20 Enter REC DIF THE STANDARD IN PRECISION

More information

M200 Handheld OTDR User s Guide

M200 Handheld OTDR User s Guide WWW.EXFIBER.COM M200 Handheld OTDR User s Guide Test & Inspection Limited Warranty One Year Limited Warranty All Noyes products are warranted against defective material and workmanship for a period of

More information

ViewConn Pro VC-8200

ViewConn Pro VC-8200 ViewConn Pro VC-8200 1. Introducing ViewConn 2. Using ViewConn Pro 3. Optional Integrated Optical Power Meter 4. Specifications Safety Fiber optic lasers use light wavelengths not visible to the human

More information

Large Vane CFM/CMM Anemometer / Psychrometer

Large Vane CFM/CMM Anemometer / Psychrometer 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com USER GUIDE Large Vane CFM/CMM Anemometer / Psychrometer Model AN310 Introduction

More information

Surface Resistivity Meter. Model SRM 232 MODE SELECT STORE SURFACE RESISTIVITY METER SRM-232 POWER. Operator s Guide

Surface Resistivity Meter. Model SRM 232 MODE SELECT STORE SURFACE RESISTIVITY METER SRM-232 POWER. Operator s Guide Surface Resistivity Meter Model SRM 232 MODE SELECT STORE SURFACE RESISTIVITY METER SRM-232 POWER Operator s Guide 2971 Oxbow Circle Cocoa, FL 32926 1.0 System Overview The SRM-232 is a small hand-held

More information

USER'S GUIDE. Optical Time Domain Reflectometer

USER'S GUIDE. Optical Time Domain Reflectometer USER'S GUIDE Optical Time Domain Reflectometer Warning and note WARNING You are cautioned that changes or modifications not espressly VISIBLE LASER RADIATION approved in this document could void yout

More information

Mini OTDR MOT-700 USER MANUAL

Mini OTDR MOT-700 USER MANUAL Mini OTDR MOT-700 USER MANUAL is registered trademark of OPTOKON, a.s. Other names and trademarks mentioned herein may be the trademarks of their respective owners. OPTOKON, a.s., Červený Kříž 250, 586

More information

USER GUIDE. Differential Thermometer Datalogger. Model HD200

USER GUIDE. Differential Thermometer Datalogger. Model HD200 USER GUIDE Differential Thermometer Datalogger Model HD200 Introduction Congratulations on your purchase of the Extech HD200 Differential Thermometer Datalogger. The HD200 supports differential temperature

More information

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer User Manual Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer Model HD350 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase

More information

F-3000 connector family SFF reliable optic connections.

F-3000 connector family SFF reliable optic connections. F-3000 connector family SFF reliable optic connections. Outline Standard product and versions The F-3000 r and rs Available technologies and standards The F-3000 fusion 2 The connector 3 Features and benefits

More information

Portable equipment N130/N330 QUICK GUIDE BASIC OPERATIONS

Portable equipment N130/N330 QUICK GUIDE BASIC OPERATIONS Portable equipment N130/N330 QUICK GUIDE BASIC OPERATIONS Instruments overview N330 Ports for sensors, power supply and USB CONNECTION PORTS 5 4 3 2 1 Connector 1: sensor Channel A input Connector 2: sensor

More information

Test & Inspection. FOCIS Flex. Fiber Optic Connector Inspection System Quick Reference Guide. or (800) , (603)

Test & Inspection. FOCIS Flex. Fiber Optic Connector Inspection System Quick Reference Guide.  or (800) , (603) Test & Inspection FOCIS Flex Fiber Optic Connector Inspection System Quick Reference Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Controls, Display, Interfaces Controls 1 Power key - 2 Image

More information

2ENTRY Helios display

2ENTRY Helios display 2ENTRY Helios display Order no. 9135240E Description Built-in set 2ENTRY Helios display will allow you to expand any kind of the base module of 2ENTRY Helios door communicator with a graphical display,

More information

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model User Manual Heavy Duty Hot Wire CFM Thermo-Anemometer Model 407119 Introduction Congratulations on your purchase of the Extech 407119 Thermo-Anemometer. The 407119 measures air velocity, air volume, and

More information

FOCIS Duel Fiber Optic Connector Inspection System User Guide

FOCIS Duel Fiber Optic Connector Inspection System User Guide Test & Inspection FOCIS Duel Fiber Optic Connector Inspection System User Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Table of Contents Safety Information....4 General Information...5 FOCIS

More information

CFM/CMM Hot-Wire Thermoanemometer

CFM/CMM Hot-Wire Thermoanemometer User Manual CFM/CMM Hot-Wire Thermoanemometer with NIST-Traceable Calibration Model 20250-16 Max Min Flow Temp THE STANDARD IN PRECISION MEASUREMENT 2 Introduction The Digi-Sense CFM/CMM Hot-Wire Thermoanemometer

More information