1 QUICK REFERENCE GUIDE KI7347C Series Optical Two Way Loss Test Set with ORL Machine Layout Basics Save Test Data Power Hard Key Functions Wavelength Tested Light Source ORL Meter Power Meter Auto Test Measurement Toggle Buttons Battery Compartment Latch
2 Layout Basics Continued Screen Cover Save Test Data Memory Recall Toggle Test Results Hard Key Functions Hidden Key Pad Power Exit Backlight Set Light Source ORL Meter Bi-Directional Test Port Power Meter 2
3 Layout Basics Continued Interchangeable Mating Sleeve Interchangeable Mating Sleeve Mating Sleeve Release Mating Sleeve Release Mating Sleeve in Closed Position Provides protection for sleeve and connector Mating Sleeve in Pivot Position Easy access for cleaning, inspecting and changing adapters 3
4 Reference Procedures Loopback Reference Procedure for Two Way Measurements NOTE: Light Source/Two Way/ ORL port must use a connector with APC polish NOTE: For two or one direction testing involving two instruments, referencing should be independently performed on both Loss Test Sets. The following will set reference at all wavelengths: Clean and inspect patch cables and testing ports before connecting any cables. Connect the Light Source /Two Way /ORL port to the Power Meter port of the same instrument using the proper patch cable. Select [POWER], Press [Autotest], then press [Abs/Rel] and then press [Set Ref] for 3 seconds. Meters will display BUSY and then 0.00 db R. Loopback Reference Side By Side Reference for Two Way Testing Referencing is performed on one of the instruments, which will set reference at all wavelengths on both Loss Test Sets: Connect the Light Source /Two Way /ORL ports of the instruments. Select [POWER], [Autotest] ], [Abs/Rel] and press [Set Ref] for 3 seconds. Meters will display BUSY and then 0.00 db R. Side by Side Reference for Two Way Testing 4
5 Reference Procedures Continued Side by Side Reference for Single Direction Testing Connect the Light Source/Two Way/ORL port to the power meter of the second instrument. Select [POWER] on both instruments On Light source, Press [Auto test] On Power meter, press [Abs/Rel] and [Set Ref] for 3 seconds. Meter will briefly display BUSY and then 0.00 db R. NOTE: Two patch cables can be used for the reference if required for current testing application. Side By Side Reference for Single Direction Testing Measurement Procedures TWO WAY LOSS AND ORL IN AUTOTEST This method requires a matched pair of Two Way Loss Test Sets, which will perform automated bidirectional testing and wavelength detection by data exchange between the instruments. After Two Way Loss Test Sets have been referenced: Exit Autotest on both instruments. Connect the Fiber Under Test (FUT) to the patch cables connected to the Two Way ports Press [Autotest] on one of the instruments Both instruments now show the same two way average loss in db R and display rotates through all available source wavelengths. 5
6 Two Way Test Measurements Continued Both units also display A B. A will be flashing on the unit where Autotest was initiated, and it has become the A unit. The other unit will flash B, and it has become the B unit. This only indicated which unit is A and B not the direction of test results being displayed. To step through all measurements on locked wavelength, press [ ] button on the hidden keypad. Results are displayed in this order: average bi-directional loss loss from A to B: A B loss from B to A: A B ORL at A end ORL at B end When displaying loss in one direction, the reference value will be shown on the left. Alternatively, selecting [Abs / Rel] displays the actual measured dbm value and source nominal output power. To determine what direction the test result is being displayed in look for the change between the A and B icons when you press the [ ] on the hidden key pad. ORL measurement from A to B ORL measurement from B to A IL measurement average A to B and B to A IL measurement one direction B to A Reference Shown - Indicates 1 direction measurement 6
7 One Way Test Measurements ONE WAY LOSS IN AUTOTEST This method is applicable for loss measurements where data communication is one way only. Testing on one fiber can be achieved with: Single Two Way Loss Test Set Two instruments used as a combination of Light source and Power meter Perform Side by Side Reference for single direction testing. Two patch cables may be used if required for testing application. Connect to the Fiber Under Test (FUT), loss will be automatically displayed. Use [-/+] to show one wavelength only. To exit Autotest, remove test lead for more than 8 seconds or turn off source Memory Functions Data can be stored in all modes, however, memory recall and cancel functions are not available in Autotest and only work in Light Source, Power Meter or Return Loss modes. Clear all memory: press both [MR] and [Exit] simultaneously for 3 seconds. clr will display. To save in next available location, press [M+]. To change next store location, press [ ] [-/+] [Set] or [Menu]. To recall, press [MR] and [-/+] to scroll memory. Use [Abs / Rel] to see db/dbm values. Hold down [Abs/ Rel] to see reference level. For data recorded in Autotest, press [-/+] to view measurements at all source wavelengths. For each wavelength, to step through all available Two Way Loss and ORL Autotest measurements, select [MR], [-/+] and then press [ ] repeatedly. Two way test only: press [ ] repeatedly to scroll details. To exit memory display, press [Menu]. 7
8 Transferring Saved Data Data transfer between the KI 7347 and Kits external software package must be completed using the USB to RS 232 cable. Install KITS software from CD provided with the Test Set or go to Once KITS program has been loaded on the computer open the program. KITS program will display the welcome screen with option for setting up the report. Note that several report options are available. For Bi- Directional Testing we will select Loss Testing and Meter Dump. Uncheck all other worksheets. Uncheck Data Logging and Meter Reading Select Setup to additional reporting criteria which must be determined. If unit is not connected to the computer this screen will appear. Connect the meter to the computer using the USB to RS 232 cable and press Connect. Once unit has been connected press Setup to continue with report setup. 8
9 This menu will allow you to select the parameters for testing as well as the report build. Be sure to confirm your Test Directions are set properly including ORL Tests at A and B locations. Otherwise this data will not be transferred. Reference End may be different depending on the reference style chosen. Confirm Wavelength for both Source and Test the press the Green Arrow. Complete the necessary data including connector type, cable length ( be sure to convert to feet or miles), splices and connectors. Confirm the number of fibers to test including what fiber to start at. This example is fiber 19. Pass/Fail standards can be compared against International or Custom. Example has established custom standards. 9
10 Now the computer should display the Live Data Worksheet without test results. To import results from the meter select Add-ins to access the KITS menu. Next Select Test Data and then Memory Download to start loading results from the machine. Once activating the memory download be sure to indicate where to start memory download from, how many results or fibers to be downloaded, wavelengths to be downloaded and what fiber ID to start at. This example has fiber 19 saved in the memory as 19. Which makes both circled values identical. 10
11 The Final Report Final report will populate with the values downloaded from the machine. This example shows failing results based on the Pass/Fail criteria the user established in previous menus. In this case Insertion Loss was excessive on all fibers at 1310 and one fiber/wavelength failed the ORL test. Certain items such as Statistical Analysis can be hidden to make the report smaller. Consult the KITS user manual for more functionality specifics Limberlost Rd Clinton NY
FX40/45 Series Manual D P RevA00 Page 1 of 25. FX40/45 Series Manual D P RevA00 Page 1 of 25
FX40/45 Series Manual D07-00-101P RevA00 Page 1 of 25 FX40/45 Series Manual D07-00-101P RevA00 Page 1 of 25 USER MANUAL FX40/45 Series Please direct all questions to your local VeEX Sales Office, Representative,
More informationOLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide
OLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide Warranty All NOYES test equipment products are warranted for a period of (1) one year from the
More informationOFL250 OTDR. Quick Reference Guide. or +1 (800) , +1 (603)
OFL250 OTDR Quick Reference Guide www.aflglobal.com or +1 (800) 321-5298, +1 (603) 528-7780 Functional Keys Functional Keys KEY NAME KEY FUNCTION Power Press and hold (approx. 2 sec.) to turn the OFL250
More informationOTR 500 OTDR USER S MANUAL
OTR 500 OTDR USER S MANUAL Avoid exposure. Laser radiation emitted from the aperture. This product conforms to CDRH standards for laser product Per 21 CFR 1040.10 & 1040.11 1 SECTION Table of Contents
More informationTraining Training Manual: Manual: KI9800A Series Pocket Fibre Sources Level 1
June 2011 Training Manual: KI9800A Series Pocket Fibre s Level 1 Course Contents 1. Typical Applications 2. General Features 3. Models 4. Keypad 5. Instrument care 6. Operation 7. Operating Modes 8. Additional
More informationMT9085 Series. ACCESS Master. Quick User s Guide
Quick User s Guide MT9085 Series ACCESS Master For safety and warning information, please read this manual before attempting to use the equipment. Keep this manual with the equipment. MT9085 Series ACCESS
More informationOTDR Testing Quick Reference Guide
Keys OTDR Testing Quick Reference Guide Key Name Key Function Power Press and hold (approx. 1 sec.) to turn the OTDR on or off or VFL Menu L and R Tab keys Arrow keys Enter Back Test Save ON 2 Hz - Press
More informationCSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide
CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Limited Warranty All NOYES test equipment products
More informationCS260 Contractor Series OTDR
CS260 Contractor Series OTDR Quick Reference Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Functional Keys KEY NAME KEY FUNCTION Power Press and hold (~1 second) to turn the CS260 on or off.
More informationOFT-CWDM SERIES. Operation Guide. Optical Time Domain Reflectometer (OTDR) with CWDM Wavelengths V
OFT-CWDM SERIES Optical Time Domain Reflectometer (OTDR) with CWDM Wavelengths V.9.12.17 Operation Guide 1.0 OTDR Quick Start Guide Press to turn on the OTDR. Connect the fiber to the appropriate port.
More informationThunder Bolt Multi-Tester Operations Manual
Thunder Bolt Multi-Tester Operations Manual TABLE OF CONTENTS Thunder Bolt Multi-Tester Universal Features and Settings... 1 Thunder Bolt Application Operation... 2 Trace View Pane... 2 Cursor Marker
More informationOFT-3 Optical Time Domain Reflectometer User's Guide
OFT-3 Optical Time Domain Reflectometer User's Guide Revision A 02/2014 Information contained in this manual is believed to be accurate and reliable. However, no responsibility is assumed by Precision
More informationOptical CWDM Power Meter
User Manual Optical CWDM Power Meter TheFibers Inc. A-1109 Keumkang Penterium IT Tower, 282 Hagui-ro, Dongan-gu, Anyang-City, Korea Tel: +82-31-381-6108 Fax: +82-31-381-6109 Email: sales@thefibers.com
More informationKI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter
User Manual KI6503 series 48-Channel Optical DWDM Power Meter Warranty: Information in this manual is given in good faith for the benefit of the user. It cannot be used as the basis for claims against
More informationKI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter
User Manual KI6501 series Optical CWDM Power Meter Warranty: Information in this manual is given in good faith for the benefit of the user. It cannot be used as the basis for claims against Kingfisher
More informationModel RP450. Optical Power Meter
Model RP450 Optical Power Meter 143 Lake St, Laconia, NH USA 03246 603-524-8350 Fax - 603-524-8332 www.odm-inc.com RP450 REV C 1-28-11 Specifications subject to change without notice Contents Introduction
More informationFTE-7500 OTDR USER S MANUAL
FTE-7500 OTDR USER S MANUAL 8/29/2011 Avoid exposure Laser Radiation Emitted from the aperture. This product conforms to CDRH standards for laser product Per 21 CFR 1040.10 & 1040.11 Revision B SECTION
More informationFlexScan OTDR With SmartAuto and LinkMap
Test & Inspection FlexScan OTDR With SmartAuto and LinkMap Quick Reference Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Controls, Display, Interfaces 1 2 4 8 1. Power button 2. Power jack
More informationOVR Optical Time Domain Reflectometer User's Guide
OVR Optical Time Domain Reflectometer User's Guide This guide is written for use with the OVR series. This includes the standard OVR OTDRs, OVR-PON and OVR-CWDM Revision D 04/2016 Information contained
More informationOTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities
features and benefits Large LCD screen and soft key menus Source and meter in one unit Auto wavelength switching and detection USB data ports OTS-600 Series Light Source and Power Meter Photo LAN1193 Ease
More informationCertification Testing Quick Reference Guide
Keys Certification Testing Quick Reference Guide Key Name Key Function Power Press and hold (approx. 1 sec.) to turn the OTDR on or off VFL Menu ON 2Hz - Press and hold (approx. 2 sec.) LED will flash
More informationPM-204A/B. Power Meter. Operation Guide
Power Meter Operation Guide Contents 1. Introduction...3 2. Warranty...3 3. Safety Information...3 4. Preparing for Operation...4 4.1. Unpacking the instrument...4 4.2. Discharged batteries...4 4.3. AC
More informationVIAVI SmartClass OLA-55M
Data Sheet VIAVI SmartClass OLA-55M Optical Level Attenuator VIAVI Solutions VIAVI SmartClass optical handhelds go beyond the basics With more than 100,000 optical handhelds already in use, VIAVI continues
More informationUser Manual. Optical DWDM Power Meter ODPM-48
User Manual Optical DWDM Power Meter TheFibers Inc. A-1109 Keumkang Penterium IT Tower, 282 Hagui-ro, Dongan-gu, Anyang-City, Korea Tel: +82-31-381-6108 Fax: +82-31-381-6109 Email: sales@thefibers.com
More informationFTE-8000 Hand Held Optical Spectrum Analyzer
FTE-8000 Hand Held Optical Spectrum Analyzer USER S MANUAL Table of Contents SECTION PAGE 1.0 Safety........... 1 2.0 FTE-8000 Quick Start...... 2 3.0 Introduction.....3 4.0 Preparation for Use... 4 Inspection
More informationVIAVI. OLA-54 and OLA-55. SmartClass. Data Sheet. Optical Level Attenuator. VIAVI SmartClass optical handhelds go beyond the basics.
Data Sheet VIAVI TM SmartClass Optical Level Attenuator OLA-54 and OLA-55 VIAVI Solutions VIAVI SmartClass optical handhelds go beyond the basics With more than 100,000 optical handhelds already in use,
More informationFOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide
Test & Inspection FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Table of Contents Safety Information....3 How to View Device
More informationAdvanced Test Equipment Rentals ATEC (2832) OMNIScanner TM. featuring OMNIFiber TM
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMNIScanner TM featuring OMNIFiber TM the future of network testing OMNIScanner2 TM OMNIScanner LT TM OMNIFiber TM User
More informationFlexScan FS200 OTDR With SmartAuto, FleXpress and LinkMap Quick Reference Guide
Test & Inspection FlexScan FS200 OTDR With SmartAuto, FleXpress and LinkMap Quick Reference Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Controls, Display, Interfaces 1 2 4 8 1. Power button
More informationC2000 POWER METER With Data Storage
C2000 POWER METER With Data Storage Operation Instructions CONTENT 1. Features 2. Functions 3. Operation 4. Specification 2 1. Features The Appointech C2000 handheld power meter has calibrated readings
More informationKI 2600 Series Hand Held Fiber Meter KI 2400/KI 2800 Series Hand Held Fiber Source KI 2300/KI 2700 Series Hand Held Loss Test Meter
KI 2600 Series Hand Held Fiber Meter KI 2400/KI 2800 Series Hand Held Fiber Source KI 2300/KI 2700 Series Hand Held Loss Test Meter OPERATION AND MAINTENANCE GUIDE Manufacturer s Name: Manufacturer s Address:
More informationFlexScan OTDR With SmartAuto and LinkMap
FlexScan OTDR With SmartAuto and LinkMap User s Guide Test & Inspection Contents Safety Information...5 Hardware Overview...7 Controls, Display, Interfaces...7 Front Panel Buttons and Indicators...9 Battery
More informationTest & Inspection. FOCIS Duel. Fiber Optic Connector Inspection System Quick Reference Guide. or (800) , (603)
Test & Inspection FOCIS Duel Fiber Optic Connector Inspection System Quick Reference Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Controls, Display, Interfaces 1 Power key - 2 Image Capture
More informationPOL-001 Fiber-Optic In-Line Polarizer. Operation Manual
POL-001 Fiber-Optic In-Line Polarizer Operation Manual Feb. 18, 2002 General Photonics Corp. Ph: (909) 590-5473 5228 Edison Ave. Fax: (909) 902-5536 Chino, CA 91710 USA www.generalphotonics.com Document
More informationKI 2400/2800 SERIES HAND HELD FIBER SOURCE FEATURES. kingfisher.com.au. OPTICAL COMMUNICATIONS TEST APPLICATIONS (in combination with a power meter)
OPTICAL COMMUNICATIONS TEST APPLICATIONS (in combination with a power meter) Mixed single mode & multimode loss testing to 6 λ Multi-Fiber continuity & polarity testing Encircled Flux compliant testing
More informationOTS-400 Series Optical Meters, Sources and Testers A LANscape Solutions Product
OTSK-4MDSD Specs Provided by www.aaatesters.com OTS-400 Series Applications Installation, testing and troubleshooting of LAN, telco, CATV and FTTx networks Description The OTS-400 Series of intelligent
More informationMAP Insertion Loss/Return Loss Meter (morl-a1 with PCT Automation Software)
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS MAP Insertion Loss/Return Loss Meter (morl-a1 with PCT Automation Software) Key Features Mandrel-free optical return loss measurements on fiber-optic patch-cords
More information920XC Training. 920XC Handheld OTDR. Training Presentation VER 1.0
920XC Training XC fibertools 920XC Handheld OTDR Training Presentation VER 1.0 OTDR Basic Operation Laser End of fiber Probe pulse Display Processor Coupler Detector Fiber under test Rayleigh backscatter
More informationSmartClass TM Fiber FBP-HD4i/HD4iP and OLP-82/82P
SmartClass TM Fiber FBP-HD4i/HD4iP and OLP-82/82P Inspect, test, certify, and save with one device QUICK START GUIDE 22002195 REV 0 REV 0 Notice Copyright Trademarks Every effort was made to ensure that
More informationPPM-30 PON Power Meter. User s Manual. Shineway Technologies, Inc. All rights reserved.
PPM-30 PON Power Meter User s Manual Shineway Technologies, Inc. All rights reserved. PPM-30 PON Power Meter Safety Instructions Safety Terms Used in This Manual WARNING identifies any procedure or practice
More informationOperation Manual for OPM-1315 Optical Power Meter
Operation Manual for OPM-1315 Optical Power Meter www.tonercable.com Table of Contents 1. Introduction... 1,2 1.1 Summary... 1 1.2 Product Features... 2 1.3 Technical Parameters... 2 1.4 Main Applications...
More informationOptical Power Meter MT-7603
Optical Power Meter English USER'S GUIDE Optical Power Meter English WARNING You are cautioned that changes or modifications not espressly approved in this document could void yout authority to operate
More informationPM-100 SERIES. Operation Guide. Power Meter V
PM-100 SERIES Power Meter Operation Guide V5.27.16 Contents 1 Introduction...2 2 Warranty...2 3 Safety Information...3 4 Preparing for Operation...3 4.1 Unpacking the instrument...3 4.2 Discharged batteries...3
More informationFIBER. WP-TEST-FIBER-400 Optical Power Meter Owner s Manual
FIBER WP-TEST-FIBER-400 Optical Power Meter Owner s Manual Technical Support: p. 866.838.5052 2017 Wirepath Ver. 170419-1000 Contents Chapter 1. Standard Configuration... 2 Chapter 2. Overview... 2 Chapter
More informationFTE-8000-DWDM Optical Spectrum Analyzer and FTE-8000-CWDM Channel Analyzer Users Guide
FTE-8000-DWDM Optical Spectrum Analyzer and FTE-8000-CWDM Channel Analyzer Users Guide Revision D 3/2012 TTI makes every effort to insure all statements and information for the products referred to in
More informationElectronic Indicator
TIR ABS CR /MM Electronic Indicator Operating Manual Analog Display Analog Visual Display Incremental Measuring Mode SPC Cables USB, MTI, RS232 Measuring System in English or Metric Travel Reverse Auto
More informationOTS-400 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities A LANscape Solutions Product
Applications Testing and troubleshooting of various telecommunication networks Description The Corning Cable Systems OTS-400 Series of intelligent and versatile optical meters, sources and testers offers
More informationPM-212-SI3 Pocket Optical Power Meter INSTRUCTION MANUAL
PM-212-SI3 Pocket Optical Power Meter INSTRUCTION MANUAL Revision 2.4 is the registered trademark of OPTOKON, a.s. Other names and trademarks mentioned herein may be the trademarks of their respective
More informationHandheld Optical Power Meter. Model SSF-TKITP-400 OPTICAL POWER METER. Manual
Model SSF-TKITP-400 OPTICAL POWER METER Manual August 2016 Contents Chapter 1. Standard Configuration.....2 Chapter 2. Overview...........2 Chapter 3. Data Sheet.....3 Chapter 4. Function.........4 4.1
More informationWIREXPERT FIBER LOSS TEST KIT TECHNICAL REFERENCE MANUAL. WireXpert Fiber Loss Test Kit Technical Reference Manual
WireXpert Fiber Loss Test Kit Technical Reference Manual i Table of Contents Introduction... 1 Package Contents... 1 Single-mode Certification Kit... 1 Multi-mode Certification Kit... 1 Features and Benefits...
More informationDeviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved.
TC500 Ethernet Cabling Certifier Operation Manual Version 1.13 Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved. Warranty This instrument is guaranteed for a period of 2 years
More informationT0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE
T0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE INDEX 1. Interfaces and Controls...1 2. Power On...2 3. Setup...2 3.1 To set the UNIT...3 3.2 To set the LAN Length Adjustment...3 3.3 To set the COAX Length
More informationGUPM100 USB Optical Power Meter Function and Specifications
1 GUPM100 USB Optical Power Meter Function and Specifications 52082469 2 Table of Contents I. Introduction... 3 II. Device Overview... 4 III. Data Manager for Windows... 5 IV. GVIS for Windows... 9 V.
More informationAF-OLK5A Series Fiber Optic Test kit
AF-OLK5A Series Fiber Optic Test kit Description The AF-OLK5A series test kits are the complete solution necessary for the installer to test, terminate and trouble shoot fiber optic systems. These test
More informationTC41-Thermocouple Thermometers User Manual
TC41-Thermocouple Thermometers User Manual Product Registration cs@perfect-prime.com Product Introduction This thermometer can be used to measure up to 4 different temperatures simultaneously, and with
More informationDatasheet: Fiber OneShot PRO Singlemode Fiber Distance and Fault Locator; Fiber QuickMap Multimode Fiber Distance and Fault Locator
Datasheet: Fiber OneShot PRO Singlemode Fiber Distance and Fault Locator; Fiber QuickMap Multimode Fiber Distance and Fault Locator Datasheet: Fiber OneShot PRO Singlemode Fiber Distance and Fault Locator;
More informationOLS-55/56 Sm a r t Optical Laser Source A Sm a r t, Future-Proof Optical Laser Source
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS /56 Sm a r t Optical Laser Source A Sm a r t, Future-Proof Optical Laser Source Key features New Laser source with up to four wavelengths offers flexibility
More informationData Manager Software User Manual
Data Manager Software User Manual CONTENTS 1. Installation of USB Virtual COM Port driver software... 2 2. Installation of Data Manager Software... 2 3. Connecting instrument to a PC (Personal Computer)...
More informationOptical Power Meter. TrendCommunications. User Guide Testing the World s Networks
Optical Power Meter User Guide - 137800 Testing the World s Networks TrendCommunications Copyright Notice The information contained in this document is the property of Trend Communications Ltd. and is
More informationOLTS-85 SmartClass Fiber. User s Guide BN 2325/ English
OLTS-85 SmartClass Fiber User s Guide BN 2325/98.21 2016.01 English Please direct all inquiries to your local Viavi sales company. The addresses can be found at: www.viavisolutions.com/en-us/contact-sales-expert
More informationInstallation and Operation Manual Model 9A02 Software Version 2.0
Installation and Operation Manual Model 9A02 Software Version 2.0 AccessPCHT Installation and Operation Welcome to the AccessPCHT installation and operation guide. This guide will help you install and
More informationM-Series OTDRs. User s Guide. (800) or (603)
M-Series OTDRs User s Guide www.aflglobal.com/go/noyes, (800) 321-5298 or (603) 528-7780 Limited Warranty All NOYES test equipment products are warranted for a period of (1) one year from the date of delivery
More informationAxxis Biometrics LLC. BioAxxis L113 Fingerprint Door Lock Programming Kit
Axxis Biometrics LLC BioAxxis L113 Fingerprint Door Lock Programming Kit Revision 0.14 Dec 2005 Table of Contents 1. Introduction... 2 Product Overview... 2 Main Features... 2 Packing Lists... 3 2. Operation
More informationOLT-55. Intelligent Optical Loss Tester. User s Manual
OLT- Intelligent Optical Loss Tester User s Manual Shineway Technologies, Inc. All rights reserved. Safety Instructions Safety Terms Used in This Manual The WARNING sign denotes a hazard. It calls attention
More informationTFS-3200 Series Optical Spectrum Analyzers
TFS-3200 Series Optical Spectrum Analyzers TFS-3200C - C-Band (1530 to 1561 nm) TFS-3200S - S-Band (1574 to 1608 nm) TFS-3200L - L-Band (1460 to 1530 nm) Operation Manual Trilithic Company Profile Trilithic
More informationFTE-6000 Hand Held Tuneable Laser Source
FTE-6000 Hand Held Tuneable Laser Source USER S MANUAL Avoid Exposure Laser Radiation Emitted From The Aperture This product conforms to CDRH standards for laser product Per 21 CFR 1040.10 & 1040.11 Table
More informationSCT-MMA / SCT-SMA Fiber Optic Adapters
SCT-MMA / SCT-SMA Fiber Optic Adapters USER MANUAL ENGLISH i SAFETY WARNINGS Read First: Safety and Operational Information The international electrical symbols used on the instrument or in this manual
More informationNorth America & Canada Softing Inc. Knoxville, Tennessee Tel.: Europe/Middle East/Africa
English North America & Canada Softing Inc. Knoxville, Tennessee Tel.: +1.865.251.5252 E-Mail: sales@softing.us Singapore Softing Singapore Pte. Ltd. Singapur Tel.: +65-6569-6019 E-Mail: asia-sales.itnetworks@softing.com
More informationUser Manual Fiber Certification Testing
User Manual Fiber Certification Testing User Manual Fiber Certification, WireXpert v7.1.0, build #276 WireXpert4500_Fiber_IT_EN_U_201511_102S Copyrights 2015 Softing Inc. http://itnetworks.softing.com/
More informationPM-212-MPO Pocket Optical Power Meter INSTRUCTION MANUAL
PM-212-MPO Pocket Optical Power Meter INSTRUCTION MANUAL Revision 1.2 is the registered trademark of OPTOKON, a.s. Other names and trademarks mentioned herein may be the trademarks of their respective
More informationProduct Introduction. G0306A USB 400x Video Inspection Probe
Product Introduction G0306A USB 400x Video Inspection Probe G0306A USB 400x Video Inspection Probe Product Introduction March 2014 Anritsu Corporation Slide 1 VIP Series Support Products Mainframe MU909014x/15x
More informationExcel 2013 Next Steps
Excel 2013 Next Steps ADULT SERVICES DEPARTMENT CRYSTAL LAKE PUBLIC LIBRARY 126 W. PADDOCK STREET CRYSTAL LAKE, IL 60014 815-459-1687, X7 WWW.CLPL.ORG Agenda 2 Home Toolbar Alignment Group Number Formats
More informationSCT2000 and SCT1500 Structured Cable Testers
SCT2000 and SCT1500 Structured Cable Testers USER MANUAL ENGLISH 1 SAFETY WARNINGS Read First: Safety and Operational Information The international symbols used on the instrument or in this manual are
More informationUser Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model
User Manual Dual-Input Data Logging Thermometers with NIST-Traceable Calibration Thermocouple Meter, Type J/K/T Input Model 20250-92 Thermistor Meter Model 20250-94 RTD Meter Model 20250-96 THE STANDARD
More informationElectronic Indicator
IN/MM 2ND TOL Electronic Indicator Operating Manual Non-Analog Digital Display 3 Programmable Presets and 3 Programmable Ratios Extra-Large Number Display Incremental Measuring Mode SPC Cables USB, MTI,
More informationWMC Remote Control and Receiver RRC-127 User Manual
Welcome Congratulations on your purchase of the Remote Control and Receiver for Windows Media Center. The infrared (IR) remote control and receiver let you access and manage your Media Center PC and other
More informationOptical Power Meter With VFL. User Manual
With VFL User Manual Contents 1. Summary...1 2. Functions...2 3. Specifications...3 4. Layout...4 5. Operation...5 6. Maintenance...9 7. Charge battery...9 8. Faults & Solutions...10 9. Software...10 1
More informationUser Manual. Thermocouple Thermometer with Dual Type K/J Inputs and Data Logging. Model with NIST-Traceable Calibration
User Manual Thermocouple Thermometer with Dual Type K/J Inputs and Data Logging with NIST-Traceable Calibration Model 20250-02 THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense Thermocouple
More informationThermo Scientific Orion Star A223 and Star A323 Portable RDO/DO Meter. Instruction Sheet
English RDO / DO Thermo Scientific Orion Star A223 and Star A323 Portable RDO/DO Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the appropriate wall socket
More informationOLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide
OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide 2004-2009, AFL Telecommunications, all rights reserved. COM4-00-1001 Revision E, 2009-06-16 Specifications
More informationPolymer Coated Fiber Cable (PCF)
Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability
More informationWalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8
15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8 15,0,15,0,1,14,1,14,13,2,13,2,3,12,3,12,11,4,11,4,5,10,5,10,9,6,9,6,7,8,7,8 WalkLAB Professional Conductivity-TDS-Salinity Meter HC 9021 Operations Manual 0 INTRODUCTION
More informationGI-4000 User Manual. Kobetron, Inc. P.O. Box 5489 Navarre, FL 32566
GI-4000 User Manual Kobetron, Inc. P.O. Box 5489 Navarre, FL 32566 TEL: (850) 939-5222 FAX: (850) 939-0490 EMAIL: sales@kobetron.com WEB: www.kobetron.com "Testing Tomorrow's Technology Today" TABLE OF
More informationRa Series Fiber Optic Test Instruments
Ra Series Fiber Optic Test Instruments Ra Series Fiber Optic Test Instruments The Datacom Textron Ra Series are innovative, easy to use instruments for the field-testing, certifying and maintenance of
More informationProfessional Thermocouple Thermometer with Four Type K Inputs, Data Logging, and Optional Infrared Wand
User Manual Professional Thermocouple Thermometer with Four Type K Inputs, Data Logging, and Optional Infrared Wand with NIST-Traceable Calibration Model 20250-20 Enter REC DIF THE STANDARD IN PRECISION
More informationM200 Handheld OTDR User s Guide
WWW.EXFIBER.COM M200 Handheld OTDR User s Guide Test & Inspection Limited Warranty One Year Limited Warranty All Noyes products are warranted against defective material and workmanship for a period of
More informationViewConn Pro VC-8200
ViewConn Pro VC-8200 1. Introducing ViewConn 2. Using ViewConn Pro 3. Optional Integrated Optical Power Meter 4. Specifications Safety Fiber optic lasers use light wavelengths not visible to the human
More informationLarge Vane CFM/CMM Anemometer / Psychrometer
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com USER GUIDE Large Vane CFM/CMM Anemometer / Psychrometer Model AN310 Introduction
More informationSurface Resistivity Meter. Model SRM 232 MODE SELECT STORE SURFACE RESISTIVITY METER SRM-232 POWER. Operator s Guide
Surface Resistivity Meter Model SRM 232 MODE SELECT STORE SURFACE RESISTIVITY METER SRM-232 POWER Operator s Guide 2971 Oxbow Circle Cocoa, FL 32926 1.0 System Overview The SRM-232 is a small hand-held
More informationUSER'S GUIDE. Optical Time Domain Reflectometer
USER'S GUIDE Optical Time Domain Reflectometer Warning and note WARNING You are cautioned that changes or modifications not espressly VISIBLE LASER RADIATION approved in this document could void yout
More informationMini OTDR MOT-700 USER MANUAL
Mini OTDR MOT-700 USER MANUAL is registered trademark of OPTOKON, a.s. Other names and trademarks mentioned herein may be the trademarks of their respective owners. OPTOKON, a.s., Červený Kříž 250, 586
More informationUSER GUIDE. Differential Thermometer Datalogger. Model HD200
USER GUIDE Differential Thermometer Datalogger Model HD200 Introduction Congratulations on your purchase of the Extech HD200 Differential Thermometer Datalogger. The HD200 supports differential temperature
More informationHeavy Duty Pitot Tube Anemometer and Differential Pressure Manometer
User Manual Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer Model HD350 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase
More informationF-3000 connector family SFF reliable optic connections.
F-3000 connector family SFF reliable optic connections. Outline Standard product and versions The F-3000 r and rs Available technologies and standards The F-3000 fusion 2 The connector 3 Features and benefits
More informationPortable equipment N130/N330 QUICK GUIDE BASIC OPERATIONS
Portable equipment N130/N330 QUICK GUIDE BASIC OPERATIONS Instruments overview N330 Ports for sensors, power supply and USB CONNECTION PORTS 5 4 3 2 1 Connector 1: sensor Channel A input Connector 2: sensor
More informationTest & Inspection. FOCIS Flex. Fiber Optic Connector Inspection System Quick Reference Guide. or (800) , (603)
Test & Inspection FOCIS Flex Fiber Optic Connector Inspection System Quick Reference Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Controls, Display, Interfaces Controls 1 Power key - 2 Image
More information2ENTRY Helios display
2ENTRY Helios display Order no. 9135240E Description Built-in set 2ENTRY Helios display will allow you to expand any kind of the base module of 2ENTRY Helios door communicator with a graphical display,
More informationUser Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model
User Manual Heavy Duty Hot Wire CFM Thermo-Anemometer Model 407119 Introduction Congratulations on your purchase of the Extech 407119 Thermo-Anemometer. The 407119 measures air velocity, air volume, and
More informationFOCIS Duel Fiber Optic Connector Inspection System User Guide
Test & Inspection FOCIS Duel Fiber Optic Connector Inspection System User Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Table of Contents Safety Information....4 General Information...5 FOCIS
More informationCFM/CMM Hot-Wire Thermoanemometer
User Manual CFM/CMM Hot-Wire Thermoanemometer with NIST-Traceable Calibration Model 20250-16 Max Min Flow Temp THE STANDARD IN PRECISION MEASUREMENT 2 Introduction The Digi-Sense CFM/CMM Hot-Wire Thermoanemometer