1 RS- led Panels and Load Centers Motorized reakers Make Easy! ll relay based systems MUST be electrically protected by a circuit breaker. Motorized breakers eliminate the need for wall or rack mounted relay based systems Saves Space Saves redundant installation and hardware costs! UL listed circuit breaker with builtin internal switching capability manufactured by Time tested, in service over 0 years vailable in, 0 and 0 -, or poles for remote control of all electrical loads Robust - rated for 60k on, off, on cycles Energy efficient - O holding current or heat sinks required to maintain state - Runs cool, lasts long! utomatic load shedding and brownout protection in every panel. Emergency override funtion standard on every panel. Specifiying in easy steps. Choose the control method: SC=RS-. Choose the cabinet style: LC for load center and P for panelboard. Choose three phase () or single phase (). Choose the number of circuits: 6 or Panelboards are only available in circuits.. Choose the maximum number of controlled circuits: 0,0, 0, 0, or 0. EX: SCLC 6-0 = a phase load center with 6 circuits ( max controlled) SCP -0 = a phase panel board with circuits (0 max controlled) ll panels and load centers
2 SCLC 6-xx-Mxxx RS- led Load Center Ø, 08Y/0 Vac, wire. 00 mp Main reaker Standard RS- led Load Center MODEL UMERS SCLC 6-0-Mxxx (Up to 0 RS- controlled circuits) SCLC 6-0-Mxxx (Up to 0 RS- controlled circuits) SCLC 6-0-Mxxx (Up to 6 RS- controlled circuits) Square D QO7M00 Load Center with low-voltage sidecar. Standard back-fed Main reaker: Squared D# QO00VH. 00, (VH = k IR) [mps Interrupt Rating] ack-fed Main reaker options Part# suffix old face=mps -M00, -M00: (0kIR) Square D# QO0xx -M00, -M060, -M070 or -M090 Squared D# QOxxVH (all VH = k IR) Wire Sizes # - /0 Cu Outside dimensions 0.9" w., 9.8" h.,.9" d. RS- led Panelboard MODEL UMERS SCP -0-Mxxx (Up to 0 RS- controlled circuits) SCP -0-Mxxx (Up to 0 RS- controlled circuits) SCP -0-Mxxx (Up to 0 RS- controlled circuits) SCP -0-Mxxx (Up to 0 RS- controlled circuits) SCP -0-Mxxx (Up to RS- controlled circuits - limited by circuit code rule) Square D QOD-L M Panel with low-voltage sidecar. Standard SCP- Main reaker: mp. - 6k IR - MJG6 Main reaker options Part# suffix old face = mps -MHG, -MJG0, -MJG7 or -MJG00 Wire Sizes Main reaker: /0-0 kcmil l/cu 00% eutral has one feed lug that accepts - 0 kcmil Cu wires SCP -xx-mxxx RS- led Panelboard Ø, 08Y/0 Vac, wire. mp Main reaker Standard VILLE MODELS See for model specific design and submittal PDFs Cabinet Outline Surface mount only High voltage interior may be field inverted for top feed Copper us Enclosure ground bar. position - ga. Copper us S / MI C RS- COTROL POWER 0 supplied installed Main Lug Only -MLO option Remove ack fed main and top feed as a MLO to gain circuits. Feed from a protected disconnect. Provides access to branch breaker positions,, &. Model number becomes a SCLC 9-0-MLO (0 RS- controlled circuits) SCLC 9-0-MLO (0 RS- controlled circuits) SCLC 9-0-MLO (Up to 9 RS- controlled circuits) (Holds up to 9 one pole breakers) mp. Panel us Rating Wire size: #6 - /0 Cu Cabinet Outline Surface mount only MI X C QOD-L Panel 00% eutral Outside dimensions 8.06" w., 0" h., 6." d. RS- COTROL POWER 0 supplied installed Knockout panels supplied in both ends Optional isolated technical ground sidecar not shown LOD CETERS S / PELORDS eps SCLC -xx-mxxx RS- led Load Center Ø, 08Y/0 Vac, wire. mp Main reaker Standard RS- led Load Center MODEL UMERS SCLC -0-Mxxx (Up to 0 RS- controlled circuits) SCLC -0-Mxxx (Up to 0 RS- controlled circuits) SCLC -0-Mxxx (Up to 0 RS- controlled circuits) SCLC -0-Mxxx (Up to 0 RS- controlled circuits) Square D QOMQ Load Center with low-voltage sidecar. Standard Main reaker: Square D# QDL. mp Main reaker options Part# suffix old face=mps -M0 or -M00 Square D# QDLxxx series (all k IR) [mps Interrupt Rating] Wire Sizes Main reaker : 0 kcmil l or 0 kcmil Cu. 00% eutral has one feed lug - 0 kcmil l or - 0 kcmil Cu Outside dimensions 0.9" w., 9." h.,.9" d SCP -xx-m00 RS- led Panelboard Ø, 08Y/0 Vac, wire. 00 mp Main reaker Standard RS- led Panelboard MODEL UMERS SCP -0-M00 (Up to 0 RS- controlled circuits) SCP -0-M00 (Up to 0 RS- controlled circuits) SCP -0-M00 (Up to 0 RS- controlled circuits) SCP -0-M00 (Up to 0 RS- controlled circuits) SCP -0-M00 (Up to RS- controlled circuits - limited by circuit code rule) Square D QOD M Panel with low-voltage sidecar. Standard SCP 00 Main reaker: 00 mp. - 0k IR - L600 [mps Interrupt Rating] Wire Sizes Main reaker: #- 600 kcmil Cu or - #-0 kcmil Cu (per EC) 00% eutral has one feed lug that accepts one #-70 kcmil or two #-00 kcmil Cu wires. Outside dimensions: 8.06" w., 68." h., 6." d. Optional isolated technical ground Cabinet Outline Surface mount only Cabinet Outline Surface mount only S / High voltage interior may be field inverted for top feed Enclosure ground bar. position - ga. Copper us C MI ll Panels RS- COTROL POWER 0 supplied installed 00 Copper us MI S / C S / QOD Panel 00% eutral RS- COTROL POWER 0 supplied installed
3 RCHITECT'S and EGIEER'S SPECIFICTIOS SCP Series Serial led Panelboard ll.c. power for the /V system shall be supplied from a source capable of being remote controlled via RS- control protocol. Circuits shall be individually addressable providing on and off control via RS protocol. means of visual operator feedback shall provide an indication of circuit on/off status locally via LEDs. The system shall have brownout (undervoltage) protection; monitoring the line voltage and triggering an automatic shutdown if the line voltage drops below 9 volts for more than seconds. The system shall automatically return circuits to on state when power resumes and remains above 0 volts for more than seconds without operator intervention. The system shall have emergency shutdown capability triggered by external contacts or the system operator. Un-motorized circuits, as required, shall be supplied from the same.c. source so that a single lever main circuit breaker is dedicated to the system. Three phase panelboards shall have 00% neutrals. Single phase panelboards shall have a single neutral. Panelboards shall have a separate and attached isolated technical ground section. ll branch circuit breakers shall be bolt-on. The Serial led Panelboard system shall be the model SCP xxx series Panelboard. Manufacturer shall warrant specified equipment to be free from defects in materials and workmanship as follows: at least () months from date of purchase for line voltage equipment; at least () years from the date of purchase for control electronics Models: Single Phase, 6k IR: SCP -, SCP -, SCP -6, SCP -8, SCP -60 alanced Power, 60v-0-60v, 6k IR: SCP 9-, SCP 9- Three Phase, 6k IR: SCP -, SCP -, SCP -6, SCP -8, SCP -60 This document available in Word format: Most recent version pdf: _SCP_&E_Spec 0//
4 SC-0 RS PROTOCOL Commands set Command Decimal Hexadecimal Start byte 76 0x0 Stop byte 0 0xF0 address x0 0x6 Output address - 0 0x0 0x0 Output O 80 0x Output OFF 8 0x Output status 8 0x6 Status of all outputs 89 0xD ll O 86 0x ll OFF 87 0x Set/clear output verification status* 90 0xE *ot be implemented autoscan can distinguish between RR7 and RR9. Commands description. Outputs O command 0x0, board_address, 0x, output_address_,, output_address_m, 0xF0 m<=0 (0x0) Example: F0, turns on outputs at and 0, on st card. Outputs OFF command 0x0, board_address, 0x, output_address_,, output_address_n, 0xF0 n<=0 (0x0) Example: F0, turns off output at 9, on nd card. Outputs O/OFF command 0x0, board_address, 0x, output_address_,, output_address_m, 0x, output_address_,, output_ address_n, 0xF0 m and n<=0 (0x0) Example: F0, turns on output at and 0, and turns off output at 9, on st card. Outputs status 0x0, board_address, 0x6, output_address_,, output_address_m, 0xF0 m<=0 (0x0) Example: F0, status of outputs at and 0, on rd card. Status of all outputs 0x0, board_address, 0xD, 0xF0.6 ll O - turn on all available outputs 0x0, board_address, 0x, 0xF SC-0 Program Card
5 .7 ll OFF - turn off all available outputs 0x0, board_address, 0x, 0xF0.8 Set/clear output verification status (OT IMPLEMETED) 0x0, board_address, 0xE, output_address_i, output_ver_status_i, output_address_j, output_ver_status_j,, output_address_n, output_ver_status_n, 0xF0 output_address_i, output_ver_status_i, output_address_j, output_ver_status_j,, output_address_n, output_ ver_status_n addresses and status of outputs, n<=0 Output_ver_status coding Status Disable Enable Code 0x0 0x0 When verification status of the output is disabled, the board will always respond with no verification status for this output. Verification status shall be disabled for all outputs driving RR7 relays.. Responses. Output status codes Status Off On Fault o verification, expected off o verification, expected on Empty Code 0x0 0x0 0x0 0x0 0x0 0x06. Output status change response This response is transmitted when output(s) change(s) status for Y reason (RS command, button push, brown out, recover from brown out, emergency override, recover from emergency override). 0x0, board_address, 0x6, output_address_i, output_status_i,, output_address_n, output_status_n, 0xF0 n<=0 (0x0) Example: F0, output at is off, at is on, and at 0 is empty, on st card. Status of all ten outputs (transmitted only in reply to status of all outputs command) 0x0, board_address, 0xD, byte_,, byte_0, 0xF0 Example: 0 0 D F0, outputs thru are off, 6 thru 9 are on, and 0 is empty, on nd card. MX Device Discovery eacon request: MX\r eacon: "MX<-SDKClass=Utility><-Make=Lyntec><-Model=SC0><-Revision=.0.0>\r" SC-0 Program Card
6 Planning and Layout Worksheet s-built door label SCP 8-xx- RS- led Panelboard reaker types, sizes, positions and connections Transfer as-built information to the door label upon completion. Keep this sheet for as-built documentation vailable as PDF download SCP 8-xx (6k IR main) - bus xx = umber of controller circuits 0, 0, 0, 0 or 0. Cabinet outline - Surface mount only Outside dimensions: 8.06" w., 0" h., 6." d. Knockout panels supplied in both ends. High voltage interior may be field inverted for top feed. MI /0 max. MI C X RS- COTROL POWER QOD-L Panels 00% eutrals -0 kcmil max. Square D QOD-L Panel with sidecars. Standard back-fed Main reaker: QO00VH. 00, (VH = k IR). [mps Interrupt Rating] Main Options: -M00, -M0: 0kIR QO0xx -M00, -M060, -M070 or -M090 mps QOxxVH (all k IR) Wire: # - /0 kcmil Cu. Document # _SCP8 Planner 09/8/ Each motorized breaker is actuated by a command from a RS- control device. s-built door label example: The RS- # is the RS- address of this breaker. The board jumpers set the RS- address of the board. Each breaker has a sub-address of -0 old line around box = suggested control board: # (Top), #, # or #. Fill in box to indicate which control board this breaker is connected to Phase Phase Phase C C C C C C MI 8 mp. ^ Un-motorized. ^ Motorized-RS- # 9 mp. ^ Un-motorized. ^ Motorized-RS- # C RS- COTROL POWER 0 un-motorized breaker supplied installed. Job Panel Comments by Date 6 8 Which board? RS- Input SC-0 circuit boards in left-hand, low-voltage cabinet. RS- board address: RS- board address: RS- board address: RS- board address: RS- board address: VC input board model SCP 8-0 Lighting Panelboard 8-0 model holds up to poles. s up to 0,, or pole breakers. RS- Output board model SCP 8-0 Lighting Panelboard 8-0 model holds up to poles. s up to 0,, or pole breakers. board model SCP 8-0 Lighting Panelboard 8-0 model holds up to poles. s up to 0,, or pole breakers. board model SCP 8-0 Lighting Panelboard 8-0 model holds up to poles. s up to 0,, or pole breakers. board model SCP 8-0
7 Outline Drawing 8.06".00" 8.0".8" 6." ler High voltage interior may be field inverted for top feed SCP 8-xx Ø, 08Y/0 Vac, wire. 00 mp back-fed Main, (all k IR) Surface mount only Square D QOD-L Panel with sidecars. Standard back-fed Main reaker: QO00VH. 00, (VH = k IR). [mps Interrupt Rating] Main Options: -M00, -M0: 0kIR QO0xx -M00, -M060, -M070 or -M090 mps QOxxVH (all k IR) Wire: # - /0 kcmil Cu. ler ler ler ler C back-fed MI /0 max. C Enclosure ground bar. position, - ga. X ler POWER QOD-L Panel 00% eutrals. 0 kcmil max.." I.D. wiring access nipples between sidecars & Panelboard.00".00" 0.00" Outside Dimensions 6" w., 0" h., 6." d SCP8 Outline Drawing 09/8/
8 Outline Drawing with optional ITG sidecar.00".00" C/L 8.0".00" ler High voltage interior may be field inverted for top feed Isolated Technical Ground ar SCP 8-xx Ø, 08Y/0 Vac, wire. 00 mp back-fed Main, (all k IR) Surface mount only Square D QOD-L Panel with sidecars. Standard back-fed Main reaker: QO00VH. 00, (VH = k IR). [mps Interrupt Rating] Main Options: -M00, -M0: 0kIR QO0xx -M00, -M060, -M070 or -M090 mps QOxxVH (all k IR) Wire: # - /0 kcmil Cu. ler ler ler ler C back-fed MI /0 max. C Enclosure ground bar. position, - ga. X ler POWER QOD-L Panel 00% eutrals. 0 kcmil max. Feed /0 max. Feed /0 max. Iso-Tech Ground ranches: 6 position - ga.." I.D. wiring access nipples between sidecars & Panelboard.00".00" 0.00" Outside Dimensions 6" w., 0" h., 6." d. 6." 6.00" SCP8 ITG Outline Drawing 09/8/
9 For the most up-to-date information Selection Information H- and J- frame Thermal-magnetic Molded Case 0 and 0 mpere Frame Class 6 0 H-frame LCP-xx. MSP -xx, SCP, & RPC Main breaker suffix -MHG0 = 0 * -MHG = *Special Order Option CR on Cancellable on Returnable 0 J-frame LCP -xx. MSP -xx SCP -xx, & RPC The standard main breaker is a JGP6 and requires no suffix number. Main breaker suffix options -MJG0 = 0 -MJG7 = 7 -MJG00 = 00 -MJG = } Circuit reaker Type HD HG HJ HL JD JG JJ JL umber of Poles,,,,,,,, Current Range Interrupting Ratings 0 V UL/ 80Y/77 Vac CS/ OM 80 Vac /60 Hz 600Y/7 Vac Vac DC /0 Vdc Ratings 00 Vdc TD TD TD TD TD TD TD TD 0/0 Vac / 6/6 00/00 / / 6/6 00/00 / IEC 97- Icu/Ics 80/ Vac 8/8 / 6/6 00/00 8/8 / 6/6 00/00 00/ Vac / 8/8 / 0/0 / 8/8 / 0/0 Special Ratings Fed. Specs W-C-7/GE HCR (, -pole) Connections/Terminations Unit Mount I-Line Rear Connection Drawout Optional Lugs Unit Mount ccessories and Modifications Shunt Trip Undervoltage Trip uxiliary Switches larm Switch Motor Operator Handle Operators Handle Padlock ttachment Handle Mechanical Interlocks Optional GF Protection Trip System Type Thermal-magnetic Instantaneous-only (MCP) Molded Case Switch (utomatic) Electronic Dimensions Height I (mm) Dimensions (P Unit Width I (mm) Mount) Depth I (mm) ot available in HD and HG two-pole rating (-pole module) -pole in a -pole module. /0/0 6. (6). (0). (86) 7. (9). (0). (86) For ranch reaker Series Ratings see CIRCUIT REKERS 6 00 Schneider Electric ll Rights Reserved /0/0 overprint _H_J_Frame_Mains.pdf 09/8/ from Digest 7 page 6-
10 Series Ratings For QOD and F Panelboards Class 60, For the most up-to-date information 8 PELORDS This page contains UL Tested and Certified series combination ratings for panelboards. These ratings apply to either an integral main located in the same enclosure or a remote main located in a separate enclosure. QOD Series Ratings QOD Series Ratings (Continued) Maximum System Voltage C c 0 8- Maximum Short Circuit Current Rating (RMS Symmetrical) Integral or Remote Main Circuit reakers and Remote Main Fuses LC 600 Maximum ranch Circuit reaker Designations and llowable mpere Ranges ab Type -pole -pole -pole k MG QO () / k HD, JD QO () PL k HG, JG QO () PL Ø 00k HJ, JJ QO () PL k HL, JL QO () PL QO () DJ 00 QO () GFI / QO () VH QO () FI Ø 00k QO () Y/ QO () S QJ QO () GFI QO () PL QO () VH QO () FI models } L/LH (L) 00MC 08Y/ 0 8k L/LH (L) MC LCLC 6 L/LH (L) 0MC QO () MSLC 6 L/LH (L) 00MC SCLC 6 UM-xx QO () QO () S MSLC 8 k QO () VH QO () GFI SCLC 8 M-xx QO () PL QO () FI MSP 8 SCP 8 QO () k Q-Hf QO () GFI MSP9 QO () FI UM-xx QO () 70 0 QO () S models k QD QO () GFI LCLC M-xx QO () PL QO () VH MSLC QO () FI SCLC } QO () k ED, FDf QO () GFI QO () FI QO () k KDf QO () S QO () GFI QO () FI models QO () MSLC QO () VH MSLC 7 k HD, JD QO () GFI QO () FI MSLC 9 QO () H are series QO0VH rated k L, M QL-Hf IR. QDL k see MG QO () VH QO0Mxx HD, JD QO () PL on pg - QO () 70 d of Digest QO () VH 0 00 k (P 08 V Max.) QO () GFI 0 e QO () FI models MSP 9 MSP SCP LCP MSP SCP } { 6k 6k 6k 6k 6k 6k 6k DJ 00 EG, FGf, KGf QG M-xx QG, HG, JG UM-xx HG, JG QO () VH 0 00 (P 08 V Max.) QO () GFI 0 e QO () FI QO () QO () VH QO () H QO () QO () GFI QO () FI QO () 70 0 QO () S QO () VH QO () GFI QO () PL QO () FI QO () QO () VH QO () H QO0VH FCL QO () KCL QO () S FCL QO () GFI KCL QO () FI Max. Class J or T6 Fuses QO () VH 0 00 QO-VH QO () FI FCL QO () k KCL FCL QO () S QO () GFI KCL QO () FI k 00 Max. Class T Fuses QO () FI QO () k EJ, FJf QO () GFI QO () FI QOxxx () = UM series olt-on, UnMotorized reaker -xxx = poles. xxx = trip current. [ pole] UM-, UM-0, UM-0 [ pole] UM-, UM-0, UM-0 [ pole] UM-, UM-0, UM-0 QOxxx = UM series clip-on, UnMotorized reaker -xxx = poles. xxx = trip current. [ pole] UM-, UM-0, UM-0 [ pole] UM-, UM-0, UM-0 [ pole] UM-, UM-0, UM-0 ll & 0 breakers are HM (High Magnetic) Maximum System Voltage C c 0 00k HJ, JJ k HL. JL 00k FI, KI 00k Suffixes HID, SWD and SW may also be applied to the applicable branch circuit breakers shown above, except suffix SW may OT be applied in combination with LC main circuit breakers. Where QO () circuit breakers are shown above, QO () H, QO () VH, and QH () circuit breakers may also be used. For shown circuit breakers rated less than this maximum voltage, the indicated short circuit current rating also applies, but at the voltage rating of the circuit breaker. Only 0 circuit breakers may be used when the LC circuit breaker is rated 0, 00 or 600. Circuit breakers may not be used when the LC circuit breaker is rated 0, 00 or 600. Obsolescent. Contact your nearest Square D/Schneider Electric sales office for replacement circuit breaker. One-pole FJ circuit breakers are still available. Where QO() GFI circuit breakers are shown above, QO(), EPD circuit breakers may also be used. 00, Y/7 00,000 { 8//06 Maximum Fuses 00 Class J or T6 00 Class T F Series Ratings Maximum System Voltage C Maximum Short Circuit Current Rating (RMS Symmetrical) QO () QO () VH QO () GFI QO () PL QO () FI QO () H QO0VH QO () QO () S QO () GFI QO () FI QO () QO () S QO () GFI Main Type ranch Type Poles EG, FH, FGf, KH, LH, MH, MX, HG, JG ED, ED-EPD 6,000 EG EC-G 00,000 EJ, FC, FJf, KC, LC, LX, HJ, JJ EG 0 EJ, FC, KC, HJ, JJ EC-G,000 HL, JL EG, EC-G 00,000 FI, KI, LI, LXI EG, EJ FI, KI EC-G EG, FGf, KH, LH, HG, JG ED, ED-EPD,000 EG, HG, JG EC-G 6,000 EJ, FC, FJf, KC, LC, LX, HJ, JJ EG 80Y/77 EJ, FC, KC, HJ, JJ EC-G 00,000 HL,JL EG 00,000 FI, KI, LI, LXI EG, EJ FI, KI EC-G 600Y/7 Maximum Short Circuit Current Rating (RMS Symmetrical) 8,000 HG, JG, MG,000 LH,000 LC, LE 0,000 HL, JL ED, ED-EPD EJ, FI, KH, KL, LC,. LE, LX, LI, LXI, HJ, JJ EG ED( 70 ), EG EG, EJ EG, &, &,, 6,000 FI, KI EG, EJ LI, XI EJ Remote Main Fuse 0 00, mpere Maximum Class J or T (600V) EC-G, & 00,000 80Y/77 00,000 Integral or Remote Main Circuit reakers and Remote Main Fuses 00 mpere Maximum Class J or T (600V) 00 mpere Maximum Class J or T (600V) 00 mpere Maximum Class J or T (600V) 00 mpere Maximum Class J or T (600V) ranch Circuit reaker Designations and llowable mpere Ranges ab Type -pole -pole -pole EG, EJ EG, EJ EC-G EG, EJ, &, & QOPLxxx-9 = M series olt-on, Motorized. (REMOTELY OPERTED) -xxx = poles. xxx = trip current. -9 suffix denotes special 60" control wires. [ pole] M-, M-0, M-0 [ pole] M-, M-0, M-0, M-0, M-0, M-60 [ pole] M-, M-0, M-0 QOPLxxx-9 = M series clip-on, Motorized. (REMOTELY OPERTED) -xxx = poles. xxx = trip current. -9 suffix denotes special 60" control wires. [ pole] M-, M-0, M-0 [ pole] M-, M-0, M-0, M-0, M-0, M-60 [ pole] M-, M-0, M-0 overprint: Series Ratings 09/7/ For most current version see Schneider Electric ll Rights Reserved 8//06
11 Instruction ulletin REQUIREMETS overprint document # /00 Cedar Rapids, I, US EC QO-PL (Plug-on), QO-PL (olt-on) Powerlink Remotely Operated Circuit reakers (Use in Type QO Load Centers and Type QO, QO, and QOD Panelboards) Retain for future use. Remotely Operated Circuit Requirements DGER HZRD OF ELECTRIC SHOCK, UR, OR EXPLOSIO. When servicing a branch circuit fed by a remotely operated circuit breaker, move handle of remotely operated circuit breaker to OFF position. Do not rely on remote operation to open circuit breaker. POWERLIK QO()-PL Remotely Operated Circuit reakers require a power supply capable of delivering at least two amperes at Vdc for a minimum of 0 milliseconds. One-, two-, and three-pole circuit breakers all have one internal motor, and power requirements are the same regardless of the number of poles and ampere ratings. The required power supply ampacity and control device contact rating are determined by the number of circuit breakers to be switched simultaneously (i.e., four circuit breakers switched simultaneously require a power supply and a control device contact rated 8 amperes minimum). The control device may be either a normally-open (O)/ normally-closed (C) contact; a single-pole, double-throw switch (SPDT); or other three-wire control device. Failure to follow these instructions will result in personal injury or death. CIRCUIT REKER ISTLLTIO DGER HZRD OF ELECTRIC SHOCK, EXPLOSIO, OR RC FLSH pply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See FP 70E. This equipment must be installed and serviced only by qualified electrical personnel. Turn off all power supplying this equipment before working on or inside equipment. lways use a properly rated voltage sensing device to confirm power is off. Replace all devices, doors, and covers before turning on power to this equipment. Failure to follow these instructions will result in death, or serious injury. See page for part number explanation. Turn off all power supplying this equipment before working on or inside equipment... efore installing circuit breaker turn circuit breaker handle to OFF position. Remove panelboard cover and deadfront. Verify power is off with voltage meter before proceeding. Installation of circuit breaker into panelboard/load center (refer to figure below) PL Except for remotely operated connections, QO()-PL remotely operated circuit breakers are installed in a panelboard/load center the same as conventional QO() circuit breakers. Connection of remotely operated circuit (refer to the figure on next page). Plug-on or olt-on Connector 0 C us ar Connector(s) VISI-TRIP Indicator Wire inding Screw Mounting Clip Mounting Rail Load Wire lack White Red Wires ssure that power supply and control device meet requirements listed under "Remotely Operated Circuit Requirements." ll supplied breakers have special 60 control wires. (Square D standards are 8.)
12 QO-PL (Plug-on), QO-PL (olt-on) POWERLIK Remotely Operated Circuit reakers Instruction ulletin /00 CIRCUIT REKER ISTLLTIO CUTIO HZRD OF CIRCUIT REKER DMGE. Connect the Vdc remote control wiring as shown on this page. Failure to follow these instructions can permanently damage the remotely operated circuit breaker. part numbers M series motorized circuit breakers (Snap-On) May be used in LCLC, LCP, MSLC, MSP, SLC or SP series panels. M series motorized circuit breakers (olt-on) Use only in LCP, MSP or SP Panelboards ll M & M series breakers have Square D part number suffix of -9 indicating a special 60 inch lead length for remote control wires required to connect to control boards in low voltage cabinet. ** = Stocked items **M- = mp. Square D QO-PL-9 **M- = mp. Square D QO-PL-9 **M-0 = 0 mp. Square D QO-0PL-9 **M-0 = 0 mp. Square D QO-0PL-9 **M-0 = 0 mp. Square D QO-0PL-9 **M-0 = 0 mp. Square D QO-0PL-9 Two pole motorized - call for pricing & delivery M- = mp. Square D QO-PL-9 M- = mp. Square D QO-PL-9 **M-0 = 0 mp. Square D QO-0PL-9 **M-0 = 0 mp. Square D QO-0PL-9 M-0 = 0 mp. Square D QO-0PL-9 M-0 = 0 mp. Square D QO-0PL-9 0, 0 or 60, Two pole also available on Special Order Three pole motorized - call for pricing & delivery M- = mp. Square D QO-PL-9 M- = mp. Square D QO-PL-9 M-0 = 0 mp. Square D QO-0PL-9 M-0 = 0 mp. Square D QO-0PL-9 M-0 = 0 mp. Square D QO-0PL-9 M-0 = 0 mp. Square D QO-0PL-9 also stocks UM & UM (un-motorized) QO series circuit breakers including HM (High Magnetic). Recommended for eliminating nuisance trips in high inrush applications. [ ll M & M-x's and M & M-x0's are HM breakers.] Melrose Dr., Lenexa, KS 66, US Voice 9-9- Fax or overprint //06 6. ll wiring and splicing must comply with applicable code requirements for Class circuits. Refer to paragraph 7-8 and article 7 of the ational Electrical Code. 7. Three #8 WG control wires are attached to the remotely operated circuit breaker for connection to the power supply and remote control device and should be cut to the required length to reach the splice connections. Use #8 WG or larger conductors with 600 V insulation and approved wire connectors for splices. 8. Connect the black lead of the remotely operated circuit breaker to the negative (-) terminal of the Vdc power supply. Connect the red lead of the remotely operated circuit breaker to the positive (+) terminal of the Vdc power supply. Connect the white lead of the remote control device. The remote control device provides connections between either positive or negative potential of the power supply and the white wire of the remotely operated circuit breaker, as appropriate. 9. pplying the positive potential of the power supply to the white wire (contact closure between the red wire and white wire) will operate the remote mechanism of the circuit breaker to the OFF position. pplying the negative potential of the power supply to the white wire (contact closure between the black wire and the white wire) will operate the remote mechanism of the circuit breaker to the O position. control circuit utilizing a normally open (O)/normally closed (C) contact is illustrated below. OTE: The remote mechanism will not move the circuit breaker handle. lso, the remote mechanism cannot turn power O when the circuit breaker is tripped (VISI-TRIP flag indicator showing) or when the circuit breaker handle is in the OFF position. Installation of the trim and operational checks 0. Remove corresponding twist-out from panelboard trim and replace trim.. Turn power to panelboard on.. Turn remotely operated circuit breaker handle to the O position.. Turn power to the remotely operated circuit on and test this circuit, turning remotely operated circuit breaker off remotely, then on remotely. If power to remote controlled circuit breaker load does not switch off and on, turn off power to remotely operated circuit and panelboard and check wiring. PL00. OTE: power supply is available from Square D Company, Cat. o. QOPLPS (plug-on) or QOPLPS (bolt-on). Splice not normally required with supplied breakers with 60 leads. Remotely Operated Circuit reaker Panelboard/Load Center Splice Connection (Class Wiring) In Sequencer or DMX controller O lack O + Vdc Power Supply White Red C OFF Square D Company 700 Sixth Street SW Cedar Rapids I 0 US -888-SquareD ( ) Electrical equipment should be installed, operated, serviced and maintained only by qualified personnel. o responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material Schneider Electric ll Rights Reserved
Specifiying in 5 easy steps
R- led Panels and Load enters Motorized reakers Make Easy! ll relay based systems MUT be electrically protected by a circuit breaker. Motorized breakers eliminate the need for wall or rack mounted relay
More informationG-E RR7P3 Latching Relay
LynTec RS-232 Controlled Retrofit Relay Panels Tested, complete package low labor mount next to circuit breaker panel to control C power "hot" lines Time proven, reliable, G-E RR7P3 latching relays snap
More informationThermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction
Thermal-Magnetic / Magnetic Only Molded ase ircuit reakers Introduction Table 8: reakdown of Typical atalog Number L 3 6 050 V 2100 reaker amily Y - mpere rame - 100 mpere rame K - 250 mpere rame L - 400
More informationCATALOG 2/15/13 RPC SERIES PANELBOARDS...2 RPC BASE FEATURES...3 RPC PANEL PRICING...4 G3 SERIES BREAKER PRICES (RPC)...5
LynTec CATALOG 2/15/13 RPC SERIES PANELBOARDS...2 RPC BASE FEATURES...3 RPC PANEL PRICING...4 G3 SERIES BREAKER PRICES (RPC)...5 MOTORIZED BREAKERS... 5 UNMOTORIZED BREAKERS... 5 EXTERNAL DEVICE CONTROL...5
More informationMoulded Case Circuit Breakers Selection Information
Moulded ase ircuit reakers Selection Information Industrial Thermal-Magnetic ircuit reakers lectronic Trip ircuit reakers IRUIT RKRS 3 S/UL ertified Interrupting Rating - atalogue Number Prefix ont. RMS
More informationCATALOG 03/02/17 NPAC NETWORKABLE POWER AUTOMATION CONTROL...2 RPC CONTROL PLATFORM...3 RPC SERIES PANELBOARDS...4
LynTec CATALOG 03/02/17 NPAC NETWORKABLE POWER AUTOMATION CONTROL...2 RPC CONTROL PLATFORM...3 RPC SERIES PANELBOARDS...4 RPC BASE FEATURES... 5 RPC PANEL PRICING... 6 RPC SERIES BREAKER PRICES... 7 MOTORIZED
More informationLynTec CATALOG 01/02/19 RPC CONTROL PLATFORM...2 RPC SERIES PANELBOARDS...3
LynTec CATALOG 01/02/19 RPC CONTROL PLATFORM...2 RPC SERIES PANELBOARDS...3 RPC BASE FEATURES... 4 RPC PANEL PRICING... 5 RPC SERIES BREAKER PRICES... 6 MOTORIZED BREAKERS...6 UNMOTORIZED BREAKERS...6
More informationSECTION DISCONNECT SWITCHES
SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationPowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)
PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 0CT00R/0 0 CONTENTS Description..............................................Page Description.............................................
More informationI-Line Panelboards. Innovative design, smart bus technology, and simple installation
I-Line Panelboards Innovative design, smart bus technology, and simple installation TM Smart: designed for efficient installation Simple: Efficient Installation Process I-Line Breakers Main Lugs: Fixed-mounted
More informationUL 489 DIN rail branch circuit breakers
UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options
More informationPower-Style QED-2, Series 2 Low Voltage Switchboards
Power-Style QED-2, Series 2 Low Voltage Switchboards Catalog 2742CT1001 (Addendum to 2742CT9501R12/09) 2010 Class 2742 CONTENTS Description............................................. Page Features...................................................
More informationThe City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2
The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results
More information4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...
.3 Product Description Drawout molded case circuit breaker switchboard Front accessible Front connected Through-the-door design drawout mechanism through 600A Insulated case UL 89 breakers up to 200A Visual
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More information7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching
7000 SERIES Power Switching Solutions Fig. 2: Four pole, Closed Transition Switch rated 1000 Amperes in Type 1 enclosure. Closed Transition Switching Closed Transition Switches feature main contacts that
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationQuick Start Guide TS A
Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationPLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet
Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical
More informationSECTION SWITCHBOARDS
SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS
More informationPDI Modular Compact Remote Power Panel
Guide Specifications (Revision 000, 6/17/2016) 1 GENERAL 1.1 Summary These specifications describe requirements for a remote power panel (RPP) distributing power to sensitive loads. These specifications
More informationQO and QOB Miniature Circuit Breakers
QO and QOB Miniature Circuit Breakers Catalog 0CT1R1/0 0 Class CONTENTS Description............................................. Page General Information...................................... Page Special
More informationDigital Lighting Systems, Inc.
, Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual
More informationMULTI 9 System Catalog
MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault
More informationPV Rapid Shutdown device
PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.
More informationSECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Individually Mounted Switches and Circuit Breakers Used for the following: a. Service
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More informationSECTION ( ) LIGHTING CONTROL PANELBOARD
(26 24 16.02) LIGHTING CONTROL PANELBOARD PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install Lighting Control Panelboards as specified and as shown on the contract drawings. B. The Lighting
More informationApplication Techniques CENTERLINE 2100 Motor Control Centers
POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product
More informationCANADIAN CATALOG JANUARY SENTRICITY Loadcentres and Circuit Breakers Raising the standard in residential.
CANADIAN CATALOG JANUARY 208 Loadcentres and Circuit Breakers Raising the standard in residential. 2 S E N T R I C I T Y T M L O A D C E N T R E S A N D C I R C U I T B R E A K E R S - C A N A D I A N
More informationMiniature Circuit Breakers and Supplementary Protectors. Contents
. Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.
More informationMaximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches
Series 300 Power Transfer Switches Maximum Reliability & Excellent Value With a Series 300 Transfer Switch, you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationSECTION PANELBOARDS
SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.
More informationDigital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03
Digital Lighting Systems, Inc. PD26 Two Channel Dimmer and Switch Packs PROTOCOL PD26 S2 S USER'S MANUAL PD26-UM Rev. E - 02/03 Digital Lighting Systems PD26 User's Manual - Page GENERAL DESCRIPTION The
More information2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.
A21 DIMMER CABINET SPECIFICATION. GENERAL. A.) Overview. 1.) The dimmer cabinets shall be fully digital, designed specifically for architectural and entertainment lighting applications, and shall consist
More informationUser s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1
More informationModel KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.
Model KEP Automatic Transfer Switches Service Entrance Rated Controller D Decision-Makerr MPAC 1500 Ratings Power Switching Device Molded case (MCCB) Insulated Case (ICCB) Current Voltage, Frequency 200
More informationControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet
General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.
More informationInstruction Bulletin Trim and Rail Extension Kit (6-, 12-, and 18-inch) Installation onto an NF Panelboard Class 1670
Instruction Bulletin Trim and Rail Extension Kit (6-, 12-, and 18-inch) Installation onto an NF Panelboard Class 1670 80043-763-01 06/2008 Peru, IN, USA Retain for future use. Introduction This bulletin
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationInstallation, Operation and Maintenance Manual
Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase
More informationPHOENIX CONTACT Features
36 to 120 k for small installation protection Data Sheet 2789_en_F 1 Description PHOEIX OTT 2011-04-29 2 Features The (SPD) provides surge protection in a compact, affordable package. high-energy suppression
More informationSIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET
Product Data Sheet Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ZEE BIPLANE IECAX480V225A Main Disconnect Panel Bevco Engineering Company, Inc. CONFIDENTIAL
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More information3RV1 Circuit-Breakers
SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a
More informationKBMG MULTI-SPEED BOARD
TM INSTALLATION AND OPERATION MANUAL KBMG MULTI-SPEED BOARD KB Part No. 8833 Multi-Speed Board for KBMG Series Regenerative Drive Pending! See Safety Warning on Page 1 The information contained in this
More informationTaxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V THERMAL MAGNETIC, COMMON TRIP
3804 South Street 759647263, TX Nacogdoches Phone: 9365697941 Fax: 9365604685 Catalog Number Manufacturer Description Weight per unit Product Category Features Current Rating Interrupting Rating Poles
More informationOverview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.
LX Breaker Control Panels Installation and Setup Procedure Hubbell Building Automation, Inc. 9601 Dessau Road Building One Suite 100 Austin, Texas 78754 512-450-1100 512-450-1215 Fax www.hubbell-automation.com
More informationPowerFlex 400 AC Drive Guide Specification
PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5
More informationSection 5. Lighting Controls. Table of Contents. Powerlink Integrated Control Systems. Powerlink Energy Management 5-6
Table of Contents Section Lighting Controls Powerlink Integrated Control Systems Overview -2 Components -3 Factory Assembled Panels - Powerlink Energy Management -6 1760001.fm Powerlink Lighting Control
More informationSwitched Relay Controller - Relay Panel with Breakers
Installation Instructions Model # SC-RPB INS # Contents Contents Description Page Safety....................................................................... 3 Please Read This First... 3 Introduction...
More information1. Coordination of series-rated devices is permitted where indicated on Drawings.
SECTION 16055 - OVERCURRENT PROTECTIVE DEVICE COORDINATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationCatalog Number Identification with Elements Explained V V V V X 347 V Hz
Owner s Manual 917 & 918 Remote Control Switches TABLE OF CONTENTS page Ratings & Installation... 1 2 Optional Accessories... 3 4 Troubleshooting & Parts Kits... 5 Wiring & Outline Diagrams... back of
More informationIELR Series
IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic
More information209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards
The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker
More informationIELR Rail-Mount Series Magnetic Circuit Protectors
IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series
More informationCS XL XM. EcoSystem Bus Supply
EcoSystem An EcoSystem lighting network containing more than one ballast, module, or driver requires an EcoSystem. This supply powers one or two independent EcoSystem buses with up to 64 ballasts or ballast
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors
More informationE-Series General Specifications
-Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationAcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter
AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter Install Guide Revision C (12/18) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Revision C (12/18) Turn off all power supplying equipment
More informationMSR 2400R. Rugged Power System for Military and Heavy Duty Applications
MSR 2400R Rugged Power System for Military and Heavy Duty Applications 2400 W modular power system Power supply or battery charging systems Parallel n+1 connection, up to 90A Series connection, up to 360VDC
More informationThis Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.
This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225 A, 8 to 42
More information.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical
Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of
More informationPERCENT OF RATED CURRENT
A-D Series Time Delay Values PERCENT OF RATED CURRENT NOTES: UL489 C-Series Breakers available with Delay Curves 11, 12, 14, 16, 21, 22, 24, 26, 42, 44, 46. Delay Curves 11,12,14,16,21,22,24,26,42,44,46,52,54,56:
More information1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers. 4. Electronic-grade panelboards.
SECTION 26 24 16 - PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationEnerSure Installation Guide
EnerSure Installation Guide Danger!!! The electrical components of this system may contain voltage and /or amperage sufficient to injure or kill. Installation is only to be performed by a licensed, bonded
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More informationModel KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.
Model KEP Automatic Transfer Switches Service Entrance Rated Controller D Decision-Makerr MPAC 1500 Ratings Power Switching Device Current Voltage, Frequency Molded case (MCCB) Insulated Case (ICCB) 200
More informationQuick Start Guide TS 870 ATS
Quick Start Guide TS 870 ATS 100A - 800A (with TSC 900 Controller) DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating
More informationProduct Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11
Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.
More informationInstallation Job Aid for Ethernet Routing Switch 5900 Series
Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs
More informationThese specifications describe requirements for a power distribution unit (PDU) distributing power to sensitive loads.
1 General 1.1 Summary These specifications describe requirements for a power distribution unit (PDU) distributing power to sensitive loads. 1.2 Standards The PowerHub 2 PDU shall be listed to the applicable
More informationSAVE THESE INSTRUCTIONS
READ AD FOLLOW ALL SAFETY ISTRUCTIOS! SAVE THESE ISTRUCTIOS AD DELIVER TO OWER AFTER ISTALLATIO IMPORTAT SAFETY ISTRUCTIOS! WARIG To reduce the risk of death, injury or property damage from fire, electric
More informationInstallation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET
Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering
More informationSource-Transfer Application Guide
S&C Model 6802 Automatic Switch Control Source-Transfer Application Guide Table of Contents Section Page Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this
More informationIntroduction Circuit Protection
Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short
More informationEquipment Short-Circuit Current Rating and Available Fault Current
Equipment Short-Circuit Current Rating and Available Fault Current Dan Neeser Field Application Engineer Eaton s Bussmann Business Dan.Neeser@CooperIndustries.com Agenda Interrupting Rating & Series Rating
More informationSupplemental Protectors
compact S200 Series Miniature circuit breakers S200, S200P, S200U, S200UP Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The S2 devices are
More informationPLC Racks IC697CHS782/783
5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep
More informationFree Standing Emergency Department DGL Project No SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY PART 1 - GENERAL
SECTION 26 05 73 1.1 SUMMARY OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY PART 1 - GENERAL A. This Section includes the following: 1. Requirements for computer-based, fault-current and overcurrent
More informationPowerLogic High Density Metering System 1-Meter Enclosure
PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these
More informationClose Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors
Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...
More informationINSTALLATION INSTRUCTIONS
TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215