Product Overview Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems

Size: px
Start display at page:

Download "Product Overview Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems"

Transcription

1 Product Overview Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems smart solutions for combustion and environment

2 Devices for emissions and immissions Measurement Dust / Opacity Dust Soot Dust Dust Dust Total Mercury Measuring *with range switching up to approx. 00 mg/m Comparison of emission dust monitors according to application criteria Measuring range mg/m D-R D-R 20 D-RX 250 D-R 820 F D-R 800 D-R D-R 220 Duct diameter 0. m 1m 6m 10 m 18 m D-RX 250 D-R D-R 220 D-R 800 / 820 F D-R 20 D-R 290 Exhaust gas Relative humidity Option Transmission Backward Scattering Forward Scattering Tribo Beta UV Photometer DURAG Group D R 220 D R 290 D R 20 D R D R 00 D R 800 D R 820 F D RX 250 F HM 1400 F Device TRX TÜV DIN EN US EPA GOST / EAC MCERTS Korean in situ extractive Automatic zero and control point Automatic soiling correction N/A N/A N/A N/A Fail safe shutters N/A N/A N/A N/A Range switching opt. Remote control unit Calibratable in mg/m wet Measuring ranges Detection stack Ø 1 m Detection stack Ø 5 m Sample collection/ heavy metal analysis Ext mg/m wet Ext % mg/m wet mg/m dew point mg/m wet mg/m * smoke spot number mg/m wet RZ mg/m mg/m wet C 100 C 200 C 00 C 400 C 500 C 600 C D-R 820 F F D-R 20 D-R 220 D-R 290 D-R D-R 800 D-RX % 80% 0% extractive optical mg/m wet mg/m mg/m wet tribo Ambient Dust Beta mg/m mg/m mg/m mg/m µg/nm 20 mg/m 10 mg/m 0,07mg/m 0.01 mg/m 0.06 RZ 0.2mg/m 0.2mg/m 0.01 mg/m 0.5 µg/nm N/A mg/m 8mg/m 2 mg/m 0,07 mg/m 0.01 mg/m 0.06 RZ 0.2 mg/m 0.2mg/m 0.01 mg/m 0.5 µg/nm N/A 2

3 D - I S C S1:D-FL220 S 1. 1: D - F L S p e e d S t at u s: S 1. : N or m a lm e as ur em e nt m/s D-R 20 Dust monitor The new generation stray light dust monitor for low to medium dust concentrations Continuous measurement Easy installation on standard flange Easy start-up without adjustment Automatic background compensation without light absorber Automatic control functions Integrated purge air monitoring and purge air control Minimum maintenance Remote access possible Digital interface according to VDI Measuring The new DURAG dust monitor D-R 20 is based on the back-scattered light. The light of a red laser diode illuminates the dust particles in the volume of the duct. The light scattered backward by these particles is detected and evaluated. The D-R 20 does not require a light trap. The background light in the stack is detected by means of a special optical system with dual detector and automatically compensated. Measuring head Mounting flange Supply unit with integrated purge air supply Universal operation unit D-ISC 100 Service software D-ESI 100 incl. USB-stick and cable Weather protection covers Fully integrated failsafe shutter as protection for the device in case of a purge air failure Waste incineration plants Cement manufacturing plants Power plants with gas, oil, coal or co-firing Monitoring of ventilation systems Monitoring of filter systems mounting ange head universal operation unit D-ISC 100 supply unit with integrated purge air supply Suitability-tested by the TUV Cologne, test report 96/ /A Approved and certified acc. to EN MCERTS measurements dust concentration digital outputs 2 relay outputs, permissible load 60 VDC / 0 VAC / 0.5 A ranges min: 0 5 mg/m, max: mg/m backward scattering supply voltage dimensions (h x w x d) C weight 15 kg pressure hpa, optional higher supply unit 24 VDC, 0.5 A 200 x 190 x 260/410 mm duct diameter > 0.7 m purge air supply integrated blower C supply voltage 115/20 VAC, 50/60 Hz, 0.7/0.4 kw protection IP 65 dimensions 480 x 450 x 20 mm (h x w x d) outputs 0 / 4 20 ma / 400 Ohm, Modbus RTU bi-directional weight 12 kg protection IP 65

4 D-R 00 D-R Measuring device for smoke spot number / dust concentration D-R 00: Extremely sensitive device for smoke spot number. D-R 00-40: Especially sensitive device for the smallest concentration of dust, in particular in waste incineration plants. In-situ measurement directly in the flow Automatic system tests and correction of measured values Self-calibration in 4-h cycle Optics and electronics in a hermetically sealed unit - no smoke gas can enter device Maintenance-friendly, thanks to optimal purge air conduction in front of the heated optical end plates Direct access to all parameters via the operator display Automatic range selection in accordance with waste incineration directive in relation 1::9* Smoke spot number measurement in furnac- es designed for light fuel oil Fine dust measurements in processes Waste incineration Filter monitoring and emission-value in waste incineration and power plants* Measuring head Mounting flange Control and display unit light trap(s) Purge air unit Automatic range selection for dust measurement in accordance with waste incineration directive (D-R 00-40) Weather protection covers Quick-closing shutter to protect device in the event of failure of the purge air supply Halar flange coating Measuring The D-R 00 / D-R meters operate ac- cording to the scattered light method. The modulated light from a Halogen lamp illuminates the dust particles in the exhaust duct. The scattered light reflected from these particles is measured and assessed. Specifications D-R 00 Measuring range: smoke spot number 0-. Limit value II can be set as delayed disconnected contact Calibration: VDI 2066, part 8. D-R Minimum range 0-1 mg/m dust concentration. Other ranges up to 00 mg/m can be set (optional automatic switching of ranges 1::9) Calibration: EN light trap quick-closing shutter (optional) purge air unit head control and display unit Suitability-tested by the TÜV Cologne, test report 96/ Approved and certified acc. to EN Suitability-tested by the TÜV Cologne, test report 96/801004* MCERTS *D-R measurements smoke spot number (D-R 00) dust concentration (D-R 00-40) ranges D-R 00: smoke spot number 1 (5) D-R 00-40: dust concentration 1), 0 1 mg/m mg/m optional 0 00 mg/m with range switching detection limit reference point drift <1% range <0.2% of range/month back scattering zero point drift <0.2% of range/month above dew point up to 20 C, optionally higher supply voltage pressure -50 up to +20 hpa dimensions duct diameter 0. to 4 m weight 18 kg 115 / 20 VAC, 50 / 60 Hz, 50 VA head mm -20 up to +50 C remarks 1) after gravimetric calibration protection IP65 purge air supply outputs 2 0/4 20 ma/500 Ohm, optional range switching digital outputs relay outputs, permissible load 48 V / 0.5 A purge air quantity approx. 80 m /h supply voltage digital inputs 1 potential free input dimensions weight accuracy <1% of range protection IP / 20 VAC, 50 / 60 Hz, 0.7 / 0.4 kw mm 12 kg 4

5 D-R 290 Optical opacity / dust monitor Standard system for plants with small to medium dust concentrations In-situ procedure, continuous measurement Semi-conductor source with long service life Super-wide band diode (SWBD), which provides more stable results in comparison to devices with conventional LEDs Powerful microprocessor technology Measured value display on LC display in opacity, extinction or in mg/m Automatic function tests with correction of measured values in relation to soiling Optics and electronics in a hermetically sealed unit no smoke gas can enter device Easy adjustment without additional equipment Low-maintenance thanks to optimal purge air conduction Measuring The device operates using the double-pass method according to the auto-collimation. The light beam traverses the distance twice. The attenuation of the light beam by the dust content in the section is measured and evaluated Mounting flanges Measuring head Reflector Control and display unit Purge air unit optical unit re ector Bus interface, e.g. Modbus or similar Automatic quick-closing shutters to protect the head and the reflector in the event of failure of the purge air Weather protection covers, for outdoor installation Explosion proof design for EEx p, Zone 1 or Zone 2 With an additional display unit at the location, the control and display unit can be installed in up to 1000 m distance away Temperature compensation through additional analogue input Special model for distances up to 18 m with 2 purge air units Filter set for sensitivity and linearity control Plants in which the dust concentration quantity needs to be measured, e.g.: Furnace plants with semi-anthracite coal, brown coal, fuel oil and combined heating Converter plants, asphalt mixing plants Plants for cement manufacture. Suitability-tested by the TÜV Cologne, test report 96/ Approved and certified acc. to EN MCERTS purge air unit display unit measurements opacity, extinction detection limit extinction switchable ranges pressure opacity: 0 20% % reference point <0.4% of range/month extinction: drift dust: 0 80 mg/m mg/m 1) transmission zero point drift <0.4% of range/month above dew point up to 250 C, optional up to 1000 C, depending on application -50 up to +20 hpa, optional higher duct diameter 1 up to 12 m, optional up to 18 m -20 up to +50 C, optional higher supply voltage dimensions weight remarks protection IP65, Ex optional purge air supply outputs 2 0/4 20 ma / 500 Ohm, manual or automatic range switching, optional Modbus RTU, Profibus DP digital outputs digital inputs 6 programmable relay outputs, permissible load 48 V / 0.5 A 6 programmable potential free inputs VAC, 47 6 Hz, 0 VA head mm 7 kg 1) with reference to one meter of path length after gravimetric calibration purge air quantity approx. 80 m /h supply voltage dimensions weight 115/20 VAC, 50/60 Hz, 0.7 / 0.4 kw mm 12 kg accuracy <1% of range protection IP55 5

6 D-R 220 Optical dust and opacity meter Monitoring dust emissions on smaller plants and in process applications In-situ measurement directly in the flow Digital operation with microprocessor Adjustable limit value 2 contact switch outputs Measuring value integral 4/15/64 seconds Internal event memory PC-interface for easy maintenance Modbus RTU interface Measurement results shown as opacity or extinction No weather protection covers needed Non-compliant device for smaller plants Heating stations, power stations Boiler plants in industry, barracks, hospitals, schools Dust extraction and filter plants Process monitoring Filter monitoring Measuring The device operates using the double-pass method according to the auto-collimation. The light beam traverses the distance twice. The attenuation of the light beam by the dust content in the section is measured and evaluated. D-R 220 head 2 reflectors for distances 0.4 to.5 m and to 10 m Mounting flanges Supply box with purge air unit Zero point reflector Models System 1: for sections up to.25 m System 2: for sections from 2.75 m up to 10 m optical unit supply box Neutral density filters for linearity check Sighting scope Display and operating unit D-ISC 100 Service software D-ESI 100 incl. USB-stick and cable re ector measurements ranges pressure opacity, extinction accuracy <2% of range 0 25/50/100% OP detection limit <2% of range / Ext mg/m 1) mg/m³ dust transmission supply voltage 24 VDC, 0.4 A above dew point up to 200 C, optional up to 500 C, depending on application -50 up to +10 hpa, optional higher dimensions weight duct diameter ,000 mm supply box head mm -20 up to +50 C purge air supply integrated unit 2.7 kg, reflector 1.6 kg protection IP65 supply voltage VAC, 46 6 Hz, 50 VA output 0/4 20 ma / 400 Ohm dimensions digital outputs remarks 2 relay outputs 0 VA, max. 48 V / 0.5A weight protection mm 1 kg IP54 1) with reference to one meter of path length after gravimetric calibration 6

7 D-R 800 Dust monitor Innovative device with laser technology to monitor small to medium dust emission according to the new European regulations Integrated display: Measuring value, threshold value, parameter in probe In-situ procedure with continuous measurement High sensitivity Easy installation on one side of the duct Can also be deployed in thick-walled stone/ insulated channels Long lifetime, as there are no moving parts inside the duct Probe with corrosion resistant nano-tech coating Hermetically sealed electronic housing against exhaust gas Parameterisation and operation with keyboard plus easily readable display directly on device or via bus interface Automatic function test with soiling correction Two analogue outputs with adjustable ranges Automatic switching of ranges according to waste incineration directive Power stations Cement plants, the metallurgy and wood industries, chemical industry etc. Waste incineration plants Monitoring of dust filter plants Measuring The D-R 800 device works according to the prin- ciple of forward scattering. The concentrated and modulated light of a laser diode penetrates the volume. The forward-scattered light largely reflected from dust particles is measured and assessed. lance Measuring lance Supply unit with integrated purge air supply Mounting flange 10 / 240 / 500 mm Weather protection cover Temperature compensation through additional analogue input Hastelloy probe evaluation unit supply unit with integrated purge air supply RS 485 and analogue current output Suitability-tested by the TÜV Cologne, test report 96/ /A Approved and certified acc. to EN MCERTS measurements dust concentration digital outputs 4 relay outputs, programmable, 1) ranges permissible load 48 V / 0.5 A 0 10 mg/m mg/m forward scattering accuracy <1% of range limit above dew point up to 50 C detection limit <0.5% range pressure -50 up to +10 hpa reference point drift <0.7% of range/month duct diameter m zero point drift <0.15 % of range/ month probe length (from flange) 400 / 800 mm supply voltage VAC, 47 6 Hz, 50 VA -20 up to +50 C dimensions lance: / 1000 mm supply unit: mm protection IP65 weight lance: 7 kg supply unit: 1 kg outputs 2 0/4 20 ma / 500 Ohm, Modbus RTU (RS485) digital inputs 2 potential free inputs, programmable purge air supply remarks integrated into supply unit 1) after gravimetric calibration 7

8 D-R 820 F Dust concentration monitor for wet gases Sensitive system for continuous extractive dust concentration measurement in accordance with the scattered light Compact design Very low maintenance requirement In-situ method with continuous measurement High sensitivity No laborious device adjustment The D-R 820 F is used for dust con- centration in wet gases. Potential applications e.g.: Measurements in saturated gas downstream of desulfurization plants Downstream of wet cleaning plants Waste incineration plants Technological processes probe heating Measuring A defined partial current is withdrawn from the exhaust gas current. This partial current is continuously heated and diluted with clean, heated air directly in the sampling probe. This immediately lowers the relative moisture and aerosols get evaporated in the heated probe. The partial current is optically measured in the chamber. The signal is corrected by the measured dilution ratio and is thus a measure of the dust content of the exhaust gas. The system comprises a special sampling probe, the laser dust monitor, a gas conditioning unit (dilution, tempering), an injector, two fans and an electronic evaluation unit. The sampling probe and the chamber form an assembly. The electronic evaluation unit and one blower for operating the injector and one for generating the diluting air are mounted together on a rack frame. purge air for probe ( lter optional) injector probe electronics Suitability-tested by the TÜV Cologne, test report 96/ /A Approved and certified acc. to EN MCERTS control valve solenoid valve chamber chamber heating air exhaust diluting air heating diluting air fan injector air fan Measuring range dust in operation exhaust gas moisture limit value (max. 100) mg/m³ higher on request > 100 % relative humidity, max. 0g/m H 2 O as aerosol Rack frame with control unit dimensions space requirements mm (W H D) mm (W H D) Probe unit weight approx. 90 kg dimensions including probe length mm (W H D), 1000 mm protection class weight approx. 40 kg IP C probe material stainless steel, Hastelloy as option power supply 20/400 V, 50 Hz, x16 A, L, N, PE others optional protection class IP65 Connections on control unit gas air flow rate flange C current outputs 4x ma, galvanically isolated with common ground max. 280 C (higher on request) load max. 1 kohm 8 10 m³/h digital contacts 6x max. 5 V 0.4 A DN 80 PN 6 special version tube Ø100 mm digital input terminal contacts optional via switching contact to externally change between /purging max. 2.5 mm² 8

9 F Extractive beta gauge particulate monitor Dust monitor especially for wet flues - emission under dew point - and for the monitoring of blast furnace gas Automatic zero correction Pre-calibrated, unaffected by particle size, colour or moisture Sample gas flow regulated at 1 - m /h Isokinetic sampling Optional dilution sample probe for high dust concentrations or after wet scrubbers Dust collection support function for heavy metal analyses Special model with chamber purging and CO-TLV monitoring during dust monitoring of blast furnace gas Coal and oil-fired power stations Waste incineration plants (municipal waste, industrial waste and hazardous waste) Sewage sludge incineration plants Emission dust measurement after wet scrubbers or in very wet exhaust gases Heavy metal analysis Measurement of very low dust concentrations in emissions Emission dust measurement in inaccessible flues with small diameter Dust concentration measurements in process applications Measuring Determination of the dust concentration by the absorption of beta rays emitted by a radioactive emitter by particles collected from an exhaust gas flow. Heated sample probe (material or titanium), with or without dilution Heated sample line in Filter tape in gas-tight filter holder sample probe, nozzle cover foil (option) pressurized air tape-filter printer (option) counter tube C-14 source filter housing supply reel 14 C emitter and detector (Geiger-Müller counter) Sample gas cooler PLC control, also for calculating the concentration from the dust content Special design F /BFG for measure- ment of the dust concentration in toxic and explosive blast-furnace or converter gas with shut-off valves for the sample gas during filter transport and with purge gas (usually nitrogen) for line back purging. Additional gas sensors need to be installed in the deployment area of the device which close all connections to the process gas and trigger an alarm. Filter tape printer and protective sheet for supporting heavy metal analyses. PLC 4 20 ma STATI total flow vacuum pump with bypass total flow controller Venturi nozzle dilution gas Venturi nozzle Suitability-tested by the RW TÜV, test reports.5.2/209/ and 252/740/ filter advance stepping motor take-up reel sample cooler with automatic drain dilution gas control valve measurements dust concentration detection limit <0.1 mg/nm ranges mg/nm reference point <1% of range/month drift pressure duct diameter protection beta ray absorption zero point drift automatic zero point correction C, optional up to 500 C -100 up to +200 hpa >0.5 m 0 up to +50 C, cooler optional IP4 (with filter blower), upgradable to IP54 outputs 2 0/4 20 ma / 500 Ohm digital outputs 11 relay outputs, permissible load 24 V / 25 VA supply voltage dimensions weight 115 / 20 VAC, 50 / 60 Hz device: 100 VA sample probe: 1700 VA sample line: 120 VA/m separate cooling unit or cabinet heating (option): 100VA mm 250 kg digital inputs 2 potential free inputs purge air supply pressurized air 6 8 bar Error limit <5% of range option dust monitoring of blast furnace gas 9

10 D-FW /Ex Filter monitor Triboelectric filter monitor for efficiency monitoring after filter plants and for continuous dust in dry emissions Compact and rugged design Good price/performance ratio Ideal for monitoring bag filters Minimal maintenance required Early detection of filter malfunctions Savings in cost, as no preventative filter exchange is necessary. Power stations Bag filter plants of all types Dust extraction plants in the production industry Waste incineration plants Crematoriums Not suitable for use directly behind electrostatic precipitators. Measuring The filter monitor uses the triboelectric effect to determine dust loads in flowing gases. The electrical charge which the dust particles experience due to friction is picked up by a probe protruding into the dust channel and converted into a signal by electronics. The signal is proportional to the dust concentration and is calibratable at a constant gas speed. System versions D-FW 21 probe With complete electronics in the probe Probe rod length 1000 mm Fitted via 1 (G1) thread D-FW 20 filter monitor D-FW 21 probe Probe rod length 1000 mm D-FW 20-B control unit with digital display 115/20V 50/60 Hz. probe control unit Suitability-tested by the TÜV Hamburg, test report 98CU026 Measuring gas up to 500 C Ex version D-FW 240/Ex Weather protection cover Various mounting options (flange, connection piece) Probe rod lengths 80, 250, 700, 1000 mm measurements dust mass flow digital inputs* 2 potential free inputs ranges 0 100% ( velocity >5 m/s) accuracy <2% of range tribo electric detection limit <2% of range/month above dew point up to 200 C, optional up to 500 C, humidity <80% reference point drift <0.% of range/month pressure -500 up to +500 hpa zero point drift <0.% of range/month duct diameter 0. 4 m supply voltage 24 VDC, 5 VA 115 / 20 VAC, 50 / 60 Hz, 10 VA* -20 up to +50 C dimensions probe length probe: (270 + probe length) mm 80, 250, 400, 700 mm protection IP65 weight probe: max. 4.5 kg control unit: kg outputs digital outputs* 0/4 20 ma / 500 Ohm 1 relay output, permissible load 250 V / 100 VA remarks *D-FW 20 only 10

11 D-RX 250 Combined probe sensor Single rod measurement probe for simultaneous measurement of - Dust concentration [mg/nm³] - Volume flow [Nm³/h] - Temperature [ C] - Absolute pressure [hpa] Only one probe / installation opening in the exhaust gas channel Compact design, no moving parts, no consumable parts Continuous conversion to normalised dust concentration in mg/nm and to normalised volume flow in Nm /h LCD display in mg/nm, Nm /h, C and hpa, one analogue output for each measurement value Parameterization at the control unit without the need of a PC or other tools Remote connection of control and evaluation unit via two-wire bus interface up to 1000 m. For measurements in accordance with TI Air (Technical Instructions for Maintaining Air Purity), 1., 17. and 27. BImSchV Not suitable for use behind electrostatic precipitators. Please consult us Suitability-tested by the TÜV Cologne, test report 96/800006/A MCERTS Measuring The tribo probe measures the electric charge of the incident particles. The measurement of the volume flow is based on the mechanical action. The probe has two separate chambers, between which a differential pressure builds up under flow. The absolute pressure in the is measured by a pressure transmitter in one chamber of the probe Weather protection cover Switch-over cock for back purging / zero point control measurements ranges dust concentration, volume flow, absolute pressure, mg/nm³ 0 9,999,999 Nm³/h 1) C, optional 0 50 C 800 1,00 hpa dust: tribo electric volume flow: differential pressure above dew point up to 200 C, optional up to 50 C, humidity <80% The is measured directly in the centre of the flow in a separate chamber within the probe with a sensor. Dust concentration is calculated from the triboelectric signal and the volume flow. The raw data that are also measured for gas and absolute pressure are used to calculate the standard dust concentration and the standard volume flow (wet). probe transmitter di erential pressure transducer max m control and evaluation unit Automatic cyclic probe back purging for high dust concentrations Hastelloy probes for corrosive gases Purge air connection at flange detection limit reference point drift zero point drift supply voltage pressure -200 up to 200 hpa dimensions probe length <2% of range <1% of range/month <1% of range/month 115 / 20 VAC, 50 / 60 Hz, 50 VA probes: (40 + probe length) mm 250, 400, 700, 1000 mm duct diameter 0. 5 m weight probe 9.5 kg electronics 22 kg -20 up to +50 C probe back purging (option) protection IP65 insulator purging (option) outputs digital outputs 4x 0/4 20 ma / 500 Ohm, Modbus RTU (RS485) 7 relay outputs, permissible load 48 V / 0.5 A purge air supply bar continuous purge air supply approx. 2 m /h 1) digital inputs 6 potential free inputs remarks velocity >5 m/s concentration after gravimetric accuracy <2% of range calibration 11

12 D-RC 120 Automatic sampling device for gravimetric dust measurements filter head device combination probe with Pitot tube and thermocouple external sensor unit drying tower notebook pump control unit Portable system Easy handling Automatic isokinetic control Suitable for in- and out-stack sampling Highest accuracy Available in stainless steel and titanium Compliant to EN , VDI 2066, EN ISO 9096 and US-EPA Method 5 Calibration of dust monitors Control measurements Measurements at filter plants Description The D-RC 120 extracts isokinetically a partial gas stream from the gas duct whereas the extraction is controlled fully automatically. The device can be conveniently operated via Windows software. The partial gas stream is sucked through a filter in which the contained dust is deposited. The dust concentration is determined by weigh- ing the filter before and after the extraction. In parallel to the gas sampling, the measure- ments of the dust monitor under test can be recorded and averaged. D-RC 120 MD, consisting of control unit, pump, drying tower, external sensor unit, Windows software and accessories D-RC 120 FD filter head device, suitable for plane or tubular filters D-RC 120 P combination probe, heatable Technical data result sampling Option Filter head device heater for out-stack sampling gravimetric analysis dust concentration In-stack, out-stack range dust concentration: mg/m Sample Gas C - velocity m/s differential pressure: hpa absolute pressure: hpa : C - pressure hpa Sample volumetric flow rate: m /h - relative humidity % relative humidity, optional measurement Probe in saturated gas below the dew point - length mm, others on request - diameter 70 mm, quick release mounting for port - weight 1.5 kg kg / m - probe material stainless steel, optional titanium Control unit - power supply 20 VAC, 50/60 Hz, optional 115 VAC, 50/60 Hz C - protection IP - electrical interfaces 1x 12 V output for audible signal 1x ma input, e.g. for AMS 1x RS 485 with USB converter - operation operating software, requires netbook/notebook (not scope of delivery) with Windows 7 or Windows 8 - dimensions (h x w x d) approx. 50 x 280 x 250 mm - weight approx. 8.5 kg 12

13 HM TRX Total mercury analyser Measuring device for fully-automatic and continuous mercury analysis in smoke gas (without wet chemistry) Maintenance-free (6 months) dry reactor High operational safety Easy maintenance Low cross sensitivities Easily legible LC display Three month maintenance interval Waste incinerations (municipal waste, indus- trial waste, hospital waste) Sewage sludge incineration Hazardous waste incineration Steel plants with scrap metal preparation Contaminated soil burning plants Crematoriums Mercury mines and refineries Fluorescent light bulb recycling plants Measuring In the HM 1400 TRX total mercury analyser the sample gas is converted into mercury vapour by a combination of thermal and dry chemical treatment. This is then continuously measured in a photometer. The probe gas flow is measured after a gas cooler at 2 C. The concentration is calculated and displayed as dry. heated sample probe sampling probe sampling line device. Larger range with dilution device Side-mounted cooling device Integrated system to generate reference gas Heated sample pipe 0.6 m, 1.0 m, 1.5 m; 600 VA, 800 VA, 1200 VA. Suitability-tested by the TÜV Hamburg, test report GMT007/ from Approved and certified acc. to EN MCERTS zero gas lter thermocatalytic reactor calibration reactor gas/liquid separator Hg-photometer liquid watchdog pump option stack reference standard condensate measurements total mercury digital outputs 4 relay outputs, permissible load 250 V, 100 VA ranges 0 45, 0 75, µg/nm³ digital inputs 1 potential free outputs UV-absorption detection limit <0.1 µg/nm³ C reference point drift <2% ZRE pressure -50 up to +50 hpa zero point drift <0.5% ZRE automatic zero correction duct diameter >0.5 m supply voltage 20/400 VAC, 50 Hz, x L, N, PE +5 up to +0 C protection IP40 (IP54) dimensions outputs 2 0/4 20 ma/500 Ohm weight 220 kg relative expanded uncertainty instrument: 1200 VA, sample probe: 650 VA, sample line: 100 VA/m heated sample pipe: 600 VA, 800 VA, 1200 VA cabinet mm 5.5% CR purge air supply pressurized air 6 8 bar (for reference gas generator only) 1

14 F Beta gauge particulate monitor A device for the continuous monitoring of the smallest concentration of particles in the air (fine dust) C-14 method, no measurable decrease in activity Lowest radioactivity of all beta gauges, usable without licence, or disclosure Automatic zero correction Pre-calibrated device Mass-flow controlled sample flow 1m /h Extraction of a constant sample flow, irrespective of the and pressure Repeated collection on the same spot, collected particles available for compositional analysis (heavy metals) RS-22 interface and 2 analogue outputs, status signals Measuring The of the F ambi- ent dust monitor is based on the absorption of the beta rays (electrons) emitted by a radioactive emitter through particles collected from an air flow. In the F the count rate of the unloaded filter tape is measured before each collecting cycle, then dust is collected on this precise filter spot over a pre-defined period, and finally the count rate of the loaded filter tape is measured. The difference between the two count rates is evaluated in the device and displayed as dust concentration in µg/m. Sample inlets: PM-2.5 according to EN PM-10 according to EN 1241 Total dust according to VDI 246 PM-2.5 according to US-EPA PM-10 according to US-EPA Ambient air systems for monitor- ing fine dust Mobile air pollution monitoring Dust measurement in health and safety applications Interior dust measurements Measurement and collection of dust particles for compositional analysis (heavy metals) Long-term background studies in dust concentration Dust measurement and collection at problem sites and repositories Dust measurement for secondary emission of repositories (e.g. coal). Dust measurement in supply air and exhaust ducts measured value printer interface Read/ Write Data from/ to Instrument strip chart recorder Sample Probe Heater (optional) Sample Inlet Measurement of T and rel. Humidity (optional) Cover Foil (optional) Filter Tape Printer (optional) Stepping Motor for Filter Transport Take-up Reel Data processing, Control Flow-Meter Bypass-Valve GM Counter Tube C-14 Source Filter Adapter Supply Reel vacuum pump sample volume flow Filter Suitability-tested by the TÜV Munich, test report Suitability-tested by the TÜV Cologne, test report 96/ /A measurements dust concentration accuracy fulfills the quality requirements acc. to 2008/50/EU ranges µg/m³ mg/m detection limit <1 µg/m³ beta-ray absorption reference point <1% of range/month drift device: 0 up to +40 C sample inlet: -20 up to 50 C zero point drift automatic zero point correction protection IP0 supply voltage 20 VAC / 50 Hz, 110 V / 60 Hz, 400 VA outputs ma / 500 Ohm dimensions digital outputs 8 relay outputs, permissible load 24 V, 12 VA weight mm, 19 -rack mount / desk unit 1 kg digital inputs potential free inputs probe tube length standard 2 m 0.5 m possible digital interface RS 22 14

15 D-ISC 100 D-ESI 100 D-ISC 100 Universal operating and display unit in stainless steel field housing for the new generation sensors from DURAG, e.g. D-FL 100, D-FL 220, D-R 220 or D-R 20 Application Easy set-up and automatic detection of up to eight connected sensors Uniform operation of various sensors Large LC Display for measured value display Comfortable operation and handling via keypad USB interface for local device operation Remote support via intranet/ internet Modular design, expansion slots and slot for external converter available Easy update via SD memory card Power supply 24 VDC/2A for one directly connected sensor The universal operating and display unit D-ISC 100 allows the connection of up to eight devices as for instance dust and volume flow monitors. The D-ISC 100 offers access via the built-in panel, a connected PC or remote access via the intranet/internet and easy parameterization of the connected DURAG devices. The display allows direct view of the current values. 4 slots for expansion modules: - Modbus RTU interface acc. to VDI analogue outputs 0/4-20mA / 500 Ohm - 4 analogue inputs 0-20mA/100 Ohm - 4 digital inputs - 4 relay outputs 48 V/0.5A Interface converters, e.g. for - Profibus DP Software modules Analogue output 0/4-20mA / 500Ohm Housing Stainless steel 04, RAL 5017 Digital outputs relay outputs 48V/0.5A Dimensions mm Digital input Ambient 1 digital input, operation via potential-free contact -20 up to +50 C, -40 up to +60 C optional Weight Protection rating Service Interface USB, TCP/IP Supply voltage VAC, 48 62Hz 5 kg IP65 D-ESI 100 Service- and Parameterization Software Easy set-up and automatic detection of the connected sensors Uniform parameterisation of various sensors Remote support via Intranet/ Internet Communication via USB, DURAG-Modbus or Modbus TCP Application D-ESI 100 is a graphical interface for operation, parameterisation and management of the connected sensors. D-ESI 100 offers access to the parameters of the connected sensors via USB interface, the DURAG Modbus interface or via Modbus TCP. Requirements PC with Microsoft Windows operating system 7 or 8 USB interface Serial interface RS485 Ethernet interface 15

16 D-FL 100 Volume flow system Measuring system to measure flow rate in dry emissions with a probe using the differential pressure Measuring Measurement of gas velocity Calculation of volume flow at standard conditions Adjustable parameters Automatic back purging device (optional) Versions with or without counter-support and for point measurement. Three month maintenance interval Volume flow measurement at high temper- atures Plants with large or small flue cross-sections Volume flow measurement at high pressure Suitability-tested by the TÜV Cologne, test report 96/ /A Approved and certified acc. to EN MCERTS The D-FL 100 system operates ac- cording to the differential pressure. The probe has two separate chambers, between which the flow builds up a differential pressure. Taking account of the other flow parameters such as, e.g. absolute pressure and, the volume flow can be converted from operating to standard conditions with the evaluation unit. Models D-FL 100 probe assembly with assembly of transducer on the probe (not for probe ) D-FL 100 hose assembly with the transducer connection via hose line Probes Probe 1: m Probe 2: up to 4 m Probe : up to 8 m cross-over cock di erential pressure transducer ow ma Mounting flange Flow probe Counter-support Differential pressure transducer Cross-over cock Probe adapter Microprocessor evaluation unit D-FL Absolute pressure transducer Temperature transducer Display and control unit D-ISC 100 Service software D-ESI 100 Weather protection covers Automatically controlled back purging device Special designs in other materials for applications with particularly aggressive exhaust gases or high gas s dp-transducer in Ex-version ma ma evaluation unit absolute pressure transducer transducer ow probe ow direction measurements velocity, volume flow digital outputs 2 relay outputs, permissible load 48 V / 0.5 A ranges m /h / 2 50 m/s accuracy <2% of range differential pressure detection limit < m/s above dew point up to 450 C, optional up to 850 C reference point drift <0.5% of range/month pressure ±200 hpa, optional higher zero point drift <0.5% of range duct diameter m supply voltage 90 / 264 VAC, Hz, 100 VA optional 18 2 VDC -20 up to +50 C dimensions probe: (00 + probe length) mm protection IP65, Ex optional weight 2 kg + 6,8 kg/m probe length outputs 0/4 20 ma / 500 Ohm, Modbus RTU, RS485, acc. to VDI purge air supply 6 8 bar for back purging if necessary 16

17 D-FL 220 Volume flow system Measuring system for ultra-sonic of flow and volume flow, especially for wet and aggressive smoke emissions (waste incineration) In-situ method Measurement possible below dew point and for high dust concentrations Continuous measurement of normal volume flow and gas velocity Automatic zero point and reference point control New design, digital signal processing D-FL 200 compatible follow-up model Remote access possible, digital interface according to VDI Operation with or without control unit Very low maintenance Measuring The D-FL 220 system works accord- ing to the acoustic transit time differential method as well. The flow velocity resp. volume flow of the waste gas is precisely calculated from the transit time difference dependent on the direction. 2 Measuring heads 2 Purge flanges (material ) 2 Mounting flanges (Mat , FRP) Purge air unit for cleaning and cooling the sensors Terminal Box for power supply of the sensors Temperature transducer Absolute pressure transducer Universal display and control unit D-ISC 100 D-ESI 100 Service- and Parameterization Software Volume flow at low speeds Plants with damp and/or aggressive exhaust gas, e.g. in waste incineration plants. Volume flow measurement at high dust content duct head purge air Suitability-tested by the TÜV Cologne, test report 96/ /A Approved and certified acc. to EN MCERTS purge air 1) measurements velocity, volume flow, ranges 0,000,000 m /h / 0 40 m/s C detection limit reference point drift <0.% of range <0.% of range/month acoustic propagation delay zero point drift <0.2% of range/month 0 00 C, optional higher supply voltage 24 VDC, 0.5 A pressure -50 up to +20 hpa, optional higher dimensions duct diameter m, dependent weight 17 kg -20 up to +50 C head -40 up to 70 C remarks protection IP65 purge air supply outputs digital outputs 0/4 20 ma / 400 Ohm, Modbus RTU bi-directional 2 relay outputs, permissible load 48 V / 0.5 A standard head: 190 Ø 570 mm 1) optional pressure and correction purge air quantity approx. 80 m /h supply voltage digital inputs none dimensions weight accuracy <2% protection IP / 20 V, 50 / 60 Hz, 0.7 / 0.4 kw mm 12 kg 17

18 18 D-EMS 2000 Data acquisition and handling system family of modular DAHS systems for management of environmental and process data D-EMS 2000 QAL 1 certified according to EN MCERTS certified D-EMS 2000 CS QAL 1 certified according to EN MCERTS certified D-DAS 2010 Cost effective system MCERTS certified D-DAS 2000 Cost effective system Excellent cost/performance ratio Data acquisition, evaluation and reporting according to: German regulations for all plants requiring approval European Industrial Emissions Directive (IED) 2010/75/EC US EPA 40 CFR Part 60 & 75 GHG Emission Monitoring (European-, UN- FCCC-Guidelines, etc.) Country-specific requirements Suitability-tested by TÜV in accordance with German TA-Luft, 1., 2.,1., 17., and 1.BImSchV as well as the European Directives 2010/75/EC, 2000/76/EC and 2001/80/ EC considering EN Approved and certified acc. to EN MCERTS certified Management for: Emission data Water data Greenhouse gas (GHG) data Ambient Air data Meteorological data Process data etc. Main Windows based DAHS with modern designed software running on a standard pc User friendly, menu-driven software available in 19 languages Data communication unit with internal data storage system for up to 96 days for high data availability Handling of up to 20 analogue/ 640 binary in- and outputs, resolution 1 second Interfaces for hardwired 0(4) to 20 ma and/ or bus communications TCP/ IP, OPC UA, Modbus, PROFIBUS, Elan etc. Encrypted database on 2 Hard Disk Drive/ Solid State Drive as Raid-1-Array Menu leaded screens for representation of current, prognostic and historic measured data in bar graph/ chart form Free configurable screen masks, time diagrams and reports on customer request Automatic alarm and information system with comment functionality Communication with customer data network incl. interface to MS-Excel Automatic data transfer to authority via standard remote communication if required Providing of relevant data in the internet/ Intranet for person in charge, authority or public Remote Service Interface for cost effective service and support Me ing R 2 d o y > m r ays R Me ing > 2 m d o r y ays w w w Me i g Ind y Re n a y v idu >5 Pro a mor e al - iv toc s rs lu ols Syem stem ks0 W2 or0 0 on Sy st Ra em id 1 c u Ba / S. on k p HD ext S D

19 D-EMS 2000 CS Data acquisition and handling system Price effective compact system for small and middle sized plants Compact system, no additional evaluation PC required Modern flash memory technology instead of hard disks Independently operating module for acquisition, long-term storage, calculation and visualisation of environmental and process data Instrument for monitoring officially prescribed limit values with automatic logging Continuous monitoring of 1 to 12 components connected via bus communication or hard wired Main features Ba cku o p HD n /SSD D- EM S2 00 0C S Windows based and certified D-EMS 2000 software All modules from the D-EMS 2000 system are usable Excellent cost/performance ratio 6 R i Y n g M + ea r n e mo 0 P ot I s r, t D ry Da + yoco 1 s ay 1 m ls s in Three device types are available: 19 HU rack with monitor/ keyboard/ mouse 19 1HU unit with slide-in keyboard and retractable monitor Desktop version with monitor/keyboard/ mouse Emissions evaluation computer for small to medium-sized installations in all types of plants and industries Computer Intel based Dual core PC with Windows 7 & 8, 2 GB Ram and > 100 GB SSD inputs / outputs up to cards: combined card: 4 AI / 8 DI / 2 AO / 4 DO input card: 8 AI / 15 DI output card: 8 AO output card: 16 DO bus system connections Modbus RTU / TCP, PROFIBUS, Elan, OPC UA analogue-/digital inputs: 12/24 analogue-/digital outputs: 12/24 interfaces 1x VGA, 2x USB, 1x RJ 45, x serial (RS22 or RS485), BNC for DCF 77- radio clock protection IP 20 operating voltage 5 up to +40 C 115/20 VAC / 50/60 Hz / 100 VA 19

20 DURAGGROUP08/2014 Subjecttochangewithoutnotice DURAG Sales and Marketing GmbH & Co. KG Kollaustraße Hamburg, Germany Tel Fax DURAG Niederlassung Nord Kollaustraße Hamburg, Germany Tel Fax DURAG Niederlassung Ost Halsbrücker Straße Freiberg, Germany Tel Fax durag-ost@durag.de DURAG Niederlassung West An der Pönt 5a Ratingen, Germany Tel Fax durag-west@durag.de DURAG Niederlassung Süd Weidenweg Bad Boll, Germany Tel Fax durag-sued@durag.de DURAG GmbH Kollaustraße Hamburg, Germany Tel Fax info@durag.de DURAG data systems GmbH Kollaustraße 105, 2245 Hamburg, Germany Tel Fax info@durag-data.de DURAG process & systems technology gmbh Kollaustraße Hamburg, Germany Tel Fax info@durag-process.de DURAG Siena do Brasil Ltda Rua Vinte e Dois de Agosto, 66 Diadema - SP Brazil Tel r.28 Fax info@duragsiena.com.br Hegwein GmbH Am Boschwerk Stuttgart Germany Tel Fax info@hegwein.de SMITSVONK Holland B.V. P.O. Box 180, 2700 AD Zoetermeer Goudstraat 6, 2718 RC Zoetermeer Netherlands Tel Fax sales@smitsvonk.nl A Brand of DURAG GmbH Kollaustraße Hamburg, Germany Tel Fax verewa@durag.de DURAG Brazil DURAG Siena do Brasil Ltda Rua Vinte e Dois de Agosto, 66 Diadema - SP Brazil Tel r.28 Fax info@duragsiena.com.br DURAG France S.a.r.l. Parc GIP Charles de Gaulle 49, rue Léonard de Vinci, BP Goussainville CEDEX, France Tel Fax info@durag-france.fr DURAG, Inc., USA 155 Mendota Heights Road Suite 200 Mendota Heights MN 55120, USA Tel Fax durag@durag.com DURAG India Instrumentation Private Limited #27/0, 2nd Main Road Industrial Town, Rajajinagar Bengaluru , India Tel / Fax info@duragindia.com DURAG Instrumentation (Shanghai) Co., Ltd. Room 706, Dibao Plaza, No. 998 Hongxin Rd., Minhang District, Shanghai, PR China Tel Fax info@durag-cn.com DURAG Italia S.r.l. Via Carlo Panseri, 118 CIM uffici, P. secondo Novara Italy Tel Fax info@durag.it DURAG Japan Office c/o TMS Planning Inc Umena, Mishima-shi, Shizuoka-ken, Japan Tel Fax info@durag.jp DURAG Korea Office RM #111, Manhattan Building, 6-2, Yeouido-Dong, Yeongdeungpo-Gu, Seoul, Korea Tel Fax info@durag-group.co.kr DURAG RUSS OOO Andropova avenue 18/6, Office Moscow Russia Tel Fax info@durag-group.ru DURAG UK GmbH Lullington House, Ashby Road Burton-on-Trent, Staffordshire, E15 0YZ Great Britain Tel Fax durag.uk@durag.de smart solutions for combustion and environment

D-R300 / D-R320 / D-R 800 DATASHEET

D-R300 / D-R320 / D-R 800 DATASHEET D-R300 / D-R320 / D-R 800 DATASHEET JUNHO 2013 Measuring principle The D-R 300 / D-R 300-40 meters operate according to the scattered light method. The modulated light from a Halogen lamp illuminates the

More information

Product Overview. Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems

Product Overview. Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems Product Overview Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems Introduction Monitor selection 2 The DURAG GROUP develops and manufactures products in the field

More information

Product Overview. Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems

Product Overview. Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems Product Overview Emission Monitoring Ambient Monitoring Environmental and Process Data Management Systems smart solutions for combustion and environment 2 The DURAG GROUP develops and manufactures products

More information

Online data sheet DUSTHUNTER SB100 SCATTERED LIGHT DUST MEASURING DEVICES

Online data sheet DUSTHUNTER SB100 SCATTERED LIGHT DUST MEASURING DEVICES Online data sheet DUSTHUNTER SB100 DUSTHUNTER SB100 A B C D E F H I J K L M N O P Q R S T 15267 14181 certified certified Ordering information Type DUSTHUNTER SB100 Part no. On request The exact device

More information

Continuous Flow Monitoring

Continuous Flow Monitoring Product Data Sheet CODEL Continuous Flow Monitoring VCEM5000/5100 Flue Gas Flow Monitor In-situ, low maintenance devices for continuous measurement of hot gas flow Non-contact infra-red sensing Continuous

More information

MCS 100 E. Compact IR Photometer for Stack Gas Monitoring

MCS 100 E. Compact IR Photometer for Stack Gas Monitoring P R O D U C T I N F O R M A T I O N MCS 100 E Compact IR Photometer for Stack Gas Monitoring Modern Emission Measuring Technology: Compact Stack Gas Monitoring The MCS 100 E is an extremely compact multi-component

More information

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O Product Data Sheet CODEL Continuous Emission Monitoring GCEM4000 Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O In-situ, low maintenance devices for continuous process and emissions

More information

Online data sheet DUSTHUNTER SB30 SCATTERED LIGHT DUST MEASURING DEVICES

Online data sheet DUSTHUNTER SB30 SCATTERED LIGHT DUST MEASURING DEVICES Online data sheet DUSTHUNTER SB30 DUSTHUNTER SB30 A B C D E F H I J K L M N O P Q R S T Ordering information Type DUSTHUNTER SB30 Part no. On request The exact device specifications and performance data

More information

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture Residual oil content measurement OIL-Check 400 For permanent and highly precise measurement of the vaporous

More information

MID approval no. DE-08-MI004-PTB004 Date of release

MID approval no. DE-08-MI004-PTB004 Date of release 1. Identification Energy and Flow Computer Flow rate and energy calculator for liquids, gases and water steam E-DB-1000-700-01 MID approval no. DE-08-MI004-PTB004 Date of release 04.01.08 2. Area of Application

More information

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A HYGROPHIL-F, Moisture Analyzer, Type 5673-10, -11, -12, -13 series A Moisture Measurement in gases and liquids Combined moisture and temperature sensor Multiple channel analyzer, max. 3 sensors can be

More information

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. In-situ low cost, low maintenance devices for continuous process and emissions monitoring.

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. In-situ low cost, low maintenance devices for continuous process and emissions monitoring. Product Data Sheet Continuous Emission Monitoring GCEM 40 Series Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O In-situ low cost, low maintenance devices for continuous process and emissions

More information

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications HMT330 Series Humidity and Temperature Transmitters for Industrial Applications The HMT330 transmitter family has the solution for demanding industrial humidity measurements. Six models for demanding industrial

More information

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8200 Stationary gas detector (CatEx) Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result

More information

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_ Order number VA 550 housing High-pressure rig for VA 550 recoended for mounting from 10 to 100 bar Order no. 0695 0550 A_...M_ 0530 1155 Order no. VA 570 Order no. 0695 0570 0695 0571 0695 0572 0695 0573

More information

Endress Hauser CUM 740. Measuring Transmitter for Turbidity and Solids Content ISO The Power of Know How

Endress Hauser CUM 740. Measuring Transmitter for Turbidity and Solids Content ISO The Power of Know How Technical Information TI 232C/07/en 51504297 Measuring Transmitter for Turbidity and Solids Content The transmitter is used for optical solid matter content measurement in clear and turbid water and in

More information

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34) is dedicated for reliable monitoring of lubrication, hydraulic and insulation oils as well as diesel fuel. In addition to highly accurate measurement of water activity (a w ) and temperature (T), calculates

More information

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm P in mw v in m/s page 1 of 12 The SF-586b Insertion Thermal Mass Flow Meter,

More information

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing Vane wheel probe BFA25 for flow measurement of gases and liquids with egrated, configurable transducer UFA in Ex-d housing Drawing 5 Vane wheel flow probe BFA25 (Dimensions see Page 3) Measurable variables

More information

Online data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES

Online data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES Online data sheet A B C D E F H I J K L M N O P Q R S T Ordering information Type Part no. On request The exact device specifications and performance data of the product may deviate from the information

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland':` Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000054059 Evaluation system: D-EMS 2020 c/w remote emission data transmission module Manufacturer: Test Laboratory:

More information

DMT345 and DMT346 Dewpoint Transmitters

DMT345 and DMT346 Dewpoint Transmitters DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662

More information

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow

More information

Flow VA 500/

Flow VA 500/ VA 500/ 520 Verbrauch 79 What are the advantages of the flow measuring technology of CS Instruments? 1) 500 is mounted by means of a standard 1/2 ball valve. During mounting and dismounting the safety

More information

LiquiDens. SensoTech. Process density meter for liquids Product description

LiquiDens. SensoTech. Process density meter for liquids Product description SensoTech LiquiDens Process density meter for liquids Product description SensoTech GmbH, Steinfeldstraße 3, D-39179 Magdeburg-Barleben Tel +49 39203 961300, Fax +49 39203 961309, Internet www.sensotech.com

More information

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS SHORT FORM 2002 SERIES D1000 Intrinsically Safe Galvanic Isolators SERIES D1000, for DIN Rail Mounting, provide the most simple and cost effective

More information

Chart recorder. DS 500 mobile Intelligent mobile chart recorder

Chart recorder. DS 500 mobile Intelligent mobile chart recorder DS 500 mobile Intelligent mobile chart recorder The intelligent mobile chart recorder - energy analysis according to DIN EN ISO 50001 Energy analysis - ow measurement - leakage calculation at compressed

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

Laserline LDM The compact class for diode laser

Laserline LDM The compact class for diode laser Laserline LDM The compact class for diode laser Compact, Powerful and Reliable in any Application Compact The 19-inch rack mount technology offers a significant simplification of the laser integration

More information

IDS 500 mobile Intelligent mobile chart recorder

IDS 500 mobile Intelligent mobile chart recorder IDS 500 mobile Intelligent mobile chart recorder The intelligent mobile chart recorder - energy analysis according to DIN EN ISO 50001 Energy analysis - ow measurement - leakage calculation at compressed

More information

Hand-Held Thermometer Model CTH 6200

Hand-Held Thermometer Model CTH 6200 Testing and Calibration Technology Hand-Held Thermometer Model CTH 6200 WIKA Data Sheet CT 51.01 Applications Service industry Measurement and and control laboratories Industry (laboratory, workshop and

More information

Series DMHF Heat Meter

Series DMHF Heat Meter Series DMHF Heat Meter The Series DMHF adopt the MultiPulse TM Technology, Digital Signal Processing Technology and Error Correction Technology, which are the state-of-the-art non-invasive flow measurement

More information

Mercury Tracker-3000 XS

Mercury Tracker-3000 XS Member of the envea Group Mercury Tracker-3000 XS Portable Instrument for Measuring Mercury in Air and Other Gases The new Mercury Tracker-3000 XS lighter - smaller - more comfortable We updated the well-proven

More information

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions www.vaisala.com DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions The display shows measurement trends, real-time data, and measurement history. Features/Benefits Measures dew

More information

GESOTEC Advanced Industrial Temperature Monitoring & Control

GESOTEC Advanced Industrial Temperature Monitoring & Control PyroViper2 -MWIR state-of-the-art Imaging Pyrometers PyroViper TM furnace probe camera models PV2-MWIR not only provide state-of-the-art infrared imaging for industrial high temperature process scenarios

More information

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X R Calibration Technology High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X WIKA Data Sheet CT 28.01 Applications Industry (laboratory, workshop and production) Pressure transmitter manufacture

More information

Penetration - Bitumen Method - PNR 12 (automatic)

Penetration - Bitumen Method - PNR 12 (automatic) Penetration - Bitumen Method - PNR 12 (automatic) Standards depend on the selected accessories ASTM D 5, DIN 52010 (obs.), EN 1426, EN 13179-2, EN 13880-2, JIS K2207, AASHTO T49 Product group(s): Bitumen,

More information

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310 High-End Humidity and Temperature Transmitter for Demanding Process Control is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative

More information

Pneumatic Precision Pressure Controller Model CPC6000

Pneumatic Precision Pressure Controller Model CPC6000 Calibration Technology Pneumatic Precision Pressure Controller Model CPC6000 R WIKA Data Sheet CT 27.61 Applications Industry (laboratory, workshop and production) Pressure transmitter manufacture Calibration

More information

Portable low-pressure controller Model CPC2000

Portable low-pressure controller Model CPC2000 Calibration technology Portable low-pressure controller Model CPC2000 WIKA data sheet CT 27.51 Applications Mobile calibration of low-pressure measuring instruments Supply of very low positive or negative

More information

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W Duct Sensor CO₂ / Humidity / Temperature For combined measurement of CO₂, relative humidity and temperature in the duct. Dual channel CO₂ technology. The measured values are output via BACnet. NEMA 4X

More information

Portable pressure calibrator Model CPH7600

Portable pressure calibrator Model CPH7600 Calibration technology Portable pressure calibrator Model CPH7600 WIKA data sheet CT 17.01 Wally Box III Applications Calibration service companies and service industry Measurement and control laboratories

More information

DUSTTRAK II AEROSOL MONITORS MODELS 8530, 8530EP AND 8532

DUSTTRAK II AEROSOL MONITORS MODELS 8530, 8530EP AND 8532 DUSTTRAK II AEROSOL MONITORS MODELS 8530, 8530EP AND 8532 DESKTOP OR HANDHELD UNITS FOR ANY ENVIRONMENT, ANY APPLICATION DustTrak II Aerosol Monitors are battery-operated, data-logging, light-scattering

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211 Humidity and Temperature Transmitter for Continuous High Humidity The is dedicated for accurate and long term stable measurement under continuous high humidity (>85 % RH) and condensing conditions in demanding

More information

Model VDL 115 Vacuum drying chambers for flammable solvents

Model VDL 115 Vacuum drying chambers for flammable solvents Model VDL 115 Vacuum drying chambers for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber

More information

Continuous Ambient Air Quality Monitoring Systems Challenges & Recent Advances

Continuous Ambient Air Quality Monitoring Systems Challenges & Recent Advances Continuous Ambient Air Quality Monitoring Systems Challenges & Recent Advances Managing Industrial Air Emissions 21 st February 2018 1 Challenge to select the correct Continuous Ambient Air Quality Monitoring

More information

High-end pressure controller Model CPC8000

High-end pressure controller Model CPC8000 Calibration technology High-end pressure controller Model CPC8000 WIKA data sheet CT 28.01 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration

More information

Conductivity Transmitters

Conductivity Transmitters Conductivity Transmitters CDTX-90 Series Starts at $ 576 Electronics Only Display in µs, ms, kω, MΩ, ppm (TDS) Simulate Function Programmable Temperature Compensation Relay Options Dual Output Option Allows

More information

Threaded resistance thermometer Miniature design Model TR10-D

Threaded resistance thermometer Miniature design Model TR10-D Temperature Threaded resistance thermometer Miniature design Model TR10-D WIKA data sheet TE 60.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion

More information

Thermal Mass Flowmeter Sensyflow FMT200-D

Thermal Mass Flowmeter Sensyflow FMT200-D Data Sheet Thermal Mass Flowmeter Sensyflow FMT200-D Direct measurement of mass flow or standard volume flow of compressed air, nitrogen and biogas independent of media pressure and temperature Wide measuring

More information

Intrinsically Safe Barriers

Intrinsically Safe Barriers Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper

More information

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page Measuring Devices Pressure range Connection Device Page Digital display mounting, für niedrige Drücke 0 2. mbar / 2. bar 4 mm tube MPV, MPA.02 portable, hand-operated 0 1 mbar / 10 bar 4 mm tube MHA.03

More information

Pneumatic precision pressure controller Model CPC6000

Pneumatic precision pressure controller Model CPC6000 Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers

More information

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter A trademark of Spirax Sarco, Inc. Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter Description Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive,

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Advantages high measuring dynamics Nv (up to 1 : 1000) measuring range from 0.2 m/s. low measuring uncertainty, even at lowest flow velocities

Advantages high measuring dynamics Nv (up to 1 : 1000) measuring range from 0.2 m/s. low measuring uncertainty, even at lowest flow velocities M E E T I N S T R U M E N T A T I E Turfschipper 114 2292 JB Wateringen Tel. 0174 272330 Fax. 0174 272340 info@catec.nl www.catec.nl Drawing 2b Sensor TA10... ZG2b with integrated transducer U10a/U10M

More information

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310 is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative humidity (RH) and temperature (T), the transmitter also calculates parameters

More information

Performance and Efficiency

Performance and Efficiency 01 GB Performance and Efficiency Compressed air management system Superior control solutions SmartAir Master Efficiency. Performance. Monitoring. Great energy saving potential Energy management is crucial

More information

Gas-actuated thermometer Stainless steel version Model 73

Gas-actuated thermometer Stainless steel version Model 73 Temperature Gas-actuated thermometer Stainless steel version Model 73 WIKA data sheet TM 73.01 for further approvals see page 15 Applications General process instrumentation in the chemical and petrochemical

More information

Penetration: Penetrometer PNR 12 (Bitumen)

Penetration: Penetrometer PNR 12 (Bitumen) Penetration: Penetrometer PNR 12 (Bitumen) Standards depend on the selected accessories ASTM D5, EN 1426, JIS K 2207 Product group(s): User group(s): Scope: Consistency & Ductility Airports & Aviation,

More information

Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER. Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro / 26/02/ :34

Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER. Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro / 26/02/ :34 Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro 18-02-2013 / This document presents some preliminary ideas for the development of

More information

Online data sheet MEAC CEMS SOLUTIONS

Online data sheet MEAC CEMS SOLUTIONS Online data sheet MEAC A B C D E F H I J K L M N O P Q R S T Ordering information Type MEAC Part no. On request The exact device specifications and performance data of the product may deviate from the

More information

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits RHE16 Compact Multifunction Coriolis Flow Meter Transmitter Features Extremely compact footprint ideal for embedding into small systems and machines Mount remotely or in compact form Low installation cost

More information

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual Temperature and humidity regulator H3020 H3021 H3023 H3027 Instruction Manual Table of content 1. GENERAL SAFETY RULES... 3 2. GENERAL DESCRIPTION... 4 3. REGULATOR MOUNTING AND CONNECTION... 4 4. DESCRIPTION

More information

Pneumatic precision pressure controller Model CPC6000

Pneumatic precision pressure controller Model CPC6000 Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers

More information

IDS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

IDS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors IDS 400 mobile Affordable, mobile chart recorder Energy analysis - ow measurement - leakage calculation at compressed air systems Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party

More information

Portable Data LOGGING SYSTEMS. for Professionals

Portable Data LOGGING SYSTEMS. for Professionals Portable Data LOGGING SYSTEMS for Professionals Introduction SIMEX is a Polish manufacturer and supplier of industrial automation equipment. The company has been in the market for nearly 0 years and offers

More information

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow

More information

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52 Pressure Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52 WIKA data sheet PE 88.03 for further approvals see page 5 Applications For monitoring air, non-inflammable and

More information

Pneumatic High-Speed Pressure Controller Model CPC3000

Pneumatic High-Speed Pressure Controller Model CPC3000 Calibration Technology Pneumatic High-Speed Pressure Controller Model CPC3000 WIKA Data Sheet CT 27.55 Applications Industry (laboratory, workshop and production) Pressure transmitter manufacture Calibration

More information

NIR-Online Multipoint System Technical data sheet

NIR-Online Multipoint System Technical data sheet NIR-Online System Technical data sheet NIR-Online NIR-Online Sensors (MPS) are based on diode-array technology. Up to nine Heads (MPH) may be attached to one Sensor. The compact, robust instruments are

More information

Exposure Monitoring HEALTH AND SAFETY

Exposure Monitoring HEALTH AND SAFETY HEALTH AND SAFETY Exposure Monitoring SIDEPAK Personal Aerosol Monitor Model AM510 The SIDEPAK AM510 Personal Aerosol Monitor for industrial hygiene and safety professionals displays and data logs aerosol

More information

DMTFP Portable Ultrasonic Flow Meters

DMTFP Portable Ultrasonic Flow Meters DMTFP Portable Ultrasonic Flow Meters Series DMTFP Portable Transit Time Ultrasonic Flow Meter is a state-of-the-art universal transit-time flow meter using MultiPulse TM technology and low-voltage broadband

More information

Level gauges Series LS Level indicator, switch and transmitter for liquids

Level gauges Series LS Level indicator, switch and transmitter for liquids Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm

More information

Pneumatic precision pressure controller Model CPC6000

Pneumatic precision pressure controller Model CPC6000 Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers

More information

CALEC energy master The benchmark in energy measurement

CALEC energy master The benchmark in energy measurement CALEC energy master The benchmark in energy measurement District heating and cooling: New tariff structures for optimum plant management Secure investment with long-term stability Type approval to EU/2004/22

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity

More information

DS 500 Intelligent chart recorder for compressed air and gases

DS 500 Intelligent chart recorder for compressed air and gases DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation Advantages at a glance: Clear layout: 7 colour screen with touch panel...

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration

More information

Resistance thermometer With spring-loaded tip Model TR55

Resistance thermometer With spring-loaded tip Model TR55 Temperature Resistance thermometer With spring-loaded tip Model TR55 WIKA data sheet TE 60.55 for further approvals see page 2 Applications Bearing temperature measurement on: Pumps Gears Motors Special

More information

Technical Concept. Tunnel Air Shower. All Types Air Shower / Air Locks

Technical Concept. Tunnel Air Shower. All Types Air Shower / Air Locks Technical Concept Tunnel Air Shower All Types Air Shower / Air Locks Tunnel Air Shower Technical Concept Product Description Personnel air showers minimize the transfer of dust particles on cleanroom clothing

More information

Threaded thermocouple Miniature design Model TC10-D

Threaded thermocouple Miniature design Model TC10-D Temperature Threaded thermocouple Miniature design Model TC10-D WIKA data sheet TE 65.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion technology

More information

Online data sheet. FLOWSIC100 Flare MASS FLOW MEASURING DEVICES

Online data sheet. FLOWSIC100 Flare MASS FLOW MEASURING DEVICES Online data sheet FLOWSIC100 Flare MSS FLOW MESUING DEVICES MSS FLOW MESUING DEVICES B C D E F H I J K L M N O P Q S T C US Ordering information Type FLOWSIC100 Flare Part no. On request In accordance

More information

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter MST2000 Loop Powered Multivariable SMARTFLOW Transmitter MST2000 Loop Powered Multivariable SMARTFLOW Transmitter Brandt Instruments MST2000 Series Loop Powered Multivariable SMARTFLOW Transmitter sets

More information

Pulverised Fuel Flowmeter

Pulverised Fuel Flowmeter Data Sheet SS/PFMAS_ PfMaster! On-line measurement of pulverized-fuel (pf) distribution (pf split), velocity and mass flowrate improved burner and boiler stoichiometry! Measurement across total cross-section!

More information

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 ) The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integd mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up by automatic

More information

MMT330 Series Moisture and Temperature Transmitters for Oil

MMT330 Series Moisture and Temperature Transmitters for Oil MMT330 Series Moisture and Temperature Transmitters for Oil Features Continuous online measurement of moisture in oil Ball-valve installation no need to shut down the process or drain the oil Proven Vaisala

More information

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features Applications The DigitalFlow GC868 clamp-on gas flowmeter is a complete ultrasonic flow metering system for measurement of most gases, including: Natural gas Compressed air Fuel gases Erosive gases Corrosive

More information

Continuous Dew Measurement in Explosive Area for flammable and non-flammable gases. VASTHI ENGINEERS

Continuous Dew Measurement in Explosive Area for flammable and non-flammable gases. VASTHI ENGINEERS Sheet No. 1 of 5 Continuous Dew Measurement in Explosive Area for flammable and non-flammable gases. Sheet No. 2 of 5 Vasthi Engineers Moisture Analyzer Model VMA 888 is heavy duty, industrial hygrometer

More information

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) ATÜVRheinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000035007 01 Certified AMS: Manufacturer: Test lnstitute: D-EMS 2000 DURAG data systems GmbH Kollaustr.105 22453

More information

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

AIR or STACK MONITOR GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE

AIR or STACK MONITOR GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE FEATURES: AIR or STACK MONITOR THREE CHANNEL SIMULTANEOUS MEASUREMENT DETECTOR VERIFICATION CAPABILITY USING GAS & SOLID SOURCES EASY DETECTOR SYSTEM CALIBRATION WITH BUILT-IN CALIBRATION INTERFACE INTERNAL

More information

Room controller STRA-17

Room controller STRA-17 Room controller STRA-17 Application example Room 2 Room 3 Room 4 SCADA EXOline alt. RS485 Modbus Transformer STRZ-24 (Required component) STRA-17 is a preprogrammed room controller intended to control

More information

Umac Wallmaster. Ultrasonic Measurement & Control Systems for Wall Thickness & Eccentricity

Umac Wallmaster. Ultrasonic Measurement & Control Systems for Wall Thickness & Eccentricity Umac Wallmaster Ultrasonic Measurement & Control Systems for Wall Thickness & Eccentricity UMAC WALLMASTER Systems: increase the efficiency UMAC WALLMASTER systems from ZUMBACH allow in-line measurements,

More information

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B. Series The precise and reliable measurement of humidity in industrial processes is gaining more and more importance. The multifunctional transmitters series offer the ideal solution. The result of many

More information

Industrial Wet/Wet Differential Pressure Transducer

Industrial Wet/Wet Differential Pressure Transducer Industrial Wet/Wet Differential Pressure Transducer With High Over Pressure Capacity mv/v Output 0-5 Vdc Output 4-20 ma Output Model MD1-002DV Model MB1-100DV L 735 Basic Unit 1 bar = 14.5 psi 1 kg/cm

More information

Chart recorder. DS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

Chart recorder. DS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors DS 400 mobile Affordable, mobile chart recorder Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party s Internal rechargeable Li-Ion batteries, approx. 8 h continous operation Easy

More information

AIAS. Technical description

AIAS. Technical description Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains AIAS - and Efficient Heating Demand Products Controlled Tunnel Ventilation Fans 1 / 4 AIAS Technical description 2 / 9 AIAS -

More information