User s Guide. PC Tool for a Universal Bulk Ink System

Size: px
Start display at page:

Download "User s Guide. PC Tool for a Universal Bulk Ink System"

Transcription

1 User s Guide PC Tool for a Universal Bulk Ink System

2 This page is intentionally left blank 2 AP-75201, Rev. 3.0, 12/03/2013

3 TABLE OF CONTENTS 1 Introduction When to use the PC Tool Starting up the PC Tool Working with the PC Tool Explaining the messages and values on the PC Tool main screen Overview of the menus and buttons on the PC Tool main screen General overview Explaining the main menu Explaining the tabs Advanced settings Waste Bottle Connection Empty Bottle detection Ink level conditions Service mode AP-75201, Rev. 3.0, 12/03/2013

4 Error and warning tunes Pump Settings Automatic Refill Controlling the pumps Switching to the Pump control mode Controlling the working direction of the pumps Controlling the status of the pumps Switching to the normal functionality mode Example : empty procedure for cartridges Advanced system information Adjusting settings Changing the BIS configuration Calibrating the ink cartridges (only for Viper and Viper TX!!) Before calibration Select cartridge to calibrate Start calibration Set the minimum ink level Set the maximum ink level Set cartridge full ink level Changing the range Stop calibration AP-75201, Rev. 3.0, 12/03/2013

5 2.4 The Help menu Updating the Firmware of the BIS Error codes AP-75201, Rev. 3.0, 12/03/2013

6 This page is intentionally left blank 6 AP-75201, Rev. 3.0, 12/03/2013

7 1 INTRODUCTION 1.1 WHEN TO USE THE PC TOOL Purpose: Setting the BIS configuration Monitoring the BIS Updating the firmware of the BIS Controlling the pumps of the BIS 1.2 STARTING UP THE PC TOOL Procedure: Step 1 : Be sure that the BIS is connected with the PC. Step 2 : Start up the EXE file Step 3 : Go to Connection > COM Port in the main menu. Step 4 : Click the top down button and choose the correct COM port. 7 AP-75201, Rev. 3.0, 12/03/2013

8 Step 5 : Click on the button <Open COM>. Step 6 : Check if the Close COM button appears to verify if the Pc Tool is connected to the BIS. Step 7 : Click the X button in the upper right corner to close the Serial Settings window. Notes When the message Access Denied is displayed, try to connect to another (free) COM port on the PC. Make sure the BIS is connected to the corresponding COM port. 8 AP-75201, Rev. 3.0, 12/03/2013

9 2 WORKING WITH THE PC TOOL 2.1 EXPLAINING THE MESSAGES AND VALUES ON THE PC TOOL MAIN SCREEN Nr Function Value(s) 1 Maximum set ink level in cartridge Only adjustable in service mode lower than Minimum set ink level in cartridge Only adjustable in service mode higher than 60 3 Ink level in the cartridge (Digital view) Ink level in the cartridge (Analog view) Bottle number 1 4 or BIS Bottle Box Indicates the position of the bottles BIS Status 7 Communication status Active BIS mode Configuration - Connected - Disconnected - Normal Functionality - Pump control mode Cartridge Colour Head Bottles configuration - OK (no action) 8 Active cartridge state - Pumping - No sensor 9 Cartridge number 1-8 or Message window Displays the operational messages and warnings 11 Pump number 1-8 or AP-75201, Rev. 3.0, 12/03/2013

10 10 AP-75201, Rev. 1.17, 12/03/2013

11 2.2 OVERVIEW OF THE MENUS AND BUTTONS ON THE PC TOOL MAIN SCREEN General overview No Menu / button 1 Main menu 2 Tabs Explaining the main menu Menu Connection Configuration Update Help Function To connect the PC Tool with the BIS To set the BIS Configuration To update the firmware of the BIS Help screen 11 AP-75201, Rev. 1.17, 12/03/2013

12 2.2.3 Explaining the tabs Instructions: Click on the tab to make the content visible. Notes The tab Bulk Ink System [9-16] does NOT appear if the BIS is an 8 pump system. 12 AP-75201, Rev. 1.17, 12/03/2013

13 2.2.4 Advanced settings Instructions: Click on the Advanced settings tab to make the content visible. (See picture below) Frame no Item Function 13 AP-75201, Rev. 3.0, 12/03/2013

14 1 Waste bottle connection To switch the waste bottle notification to the printer on / off. 2 Empty bottle connection To switch the empty bottle sensors on / off. 3 Ink level conditions To set the error level value of the overflow sensor. 4 Service To switch to service mode 5 Error and warning tunes To switch off the error and warning tunes of the BIS. 6 Pump settings To set speed and time settings of the pumps. 7 Automatic refill To set automatic refill time. 8 Refresh Values To load the active settings form the BIS device. 14 AP-75201, Rev. 3.0, 12/03/2013

15 Waste Bottle Connection Function: To switch on, off, the waste bottle notification to the printer. This function is used to notify the printer equipped with a retro fit BIS sensor interface when an ink bottle in the BIS is empty. Only mark this option when not working with a DB25 connector. Please refer to the User s Guide for more details. Instructions: Mark the checkbox in the Waste Bottle Connection frame to enable the waste bottle notification to the printer. See image below. Unmark the button to disable the function. (See image below) 15 AP-75201, Rev. 3.0, 12/03/2013

16 Default: Empty Bottle Detection Parameter Value Default Use the waste Bottle connections On / Off On Result: When the waste bottle connection is disabled, there is No empty bottle notification to the printer and No warning tune when the waste bottle is not present. 16 AP-75201, Rev. 3.0, 12/03/2013

17 Empty Bottle detection RESERVED FOR FUTURE USE! When you change this property, the BIS system is restarted. Function: To switch the empty bottle sensors on / off. Instructions: Mark the button in the Empty Bottle Detection frame to enable the function. (See image below) Unmark the button in the Empty Bottle Detection frame to disable the function. (See image below) Values: 17 AP-75201, Rev. 3.0, 12/03/2013

18 Empty Bottle Detection Parameter Value Default Use Empty Bottle Sensors On / Off Off Default operation: = Empty bottle detection when no sensors are used The empty bottle is only detected when a pump time-out has occurred. After a time-out the system goes into an error state and a notification is send to the printer (waste bottle and DB 25 cable) 18 AP-75201, Rev. 3.0, 12/03/2013

19 Ink level conditions Function: To set the error level value of the overflow sensor. See image below for graphical interpretation. Ink level area Overflow Overflow sensor error level value 150 HIGH OK LOW EMPTY To know the actual value of the overflow sensor, see Advanced system information Instructions: To send the new value to the BIS, fill in the value in the Ink Level Conditions frame (See image below) and click the <Use> button. 19 AP-75201, Rev. 3.0, 12/03/2013

20 Values: Ink Level Conditions Parameter Value Default Overflow Detection Notes The default value is only applicable for BIS systems with Mutoh Mild Solvent ink loaded. For the Mutoh Textile Ink, the cartridges (sensors) have to be calibrated as explained further in this manual Service mode A password detected mode which is only accessible for Authorized Mutoh Technicians. 20 AP-75201, Rev. 3.0, 12/03/2013

21 Error and warning tunes Function: To switch on / off the error and warning tunes of the BIS. Instructions: Unmark the Use Error Tunes and / or Use Warning Tunes as indicated on the frame below to switch off the BIS s error tunes and / or warning tunes. Values: Error and Warning Tunes Parameter Value Default Use Error Tunes On / Off On Use Warning Tunes On / Off On Notes This property is not saved into the BIS. When the BIS is restarted the default settings (both on) are used. See the User s Guide of the BIS for an overview of the error tunes. 21 AP-75201, Rev. 3.0, 12/03/2013

22 Pump Settings Function: To set speed and time settings of the pumps. Instructions: In the Pump Settings frame, fill out the required values and pres the <Use> button to execute them. Values: Pump Settings Parameter Function Default value Max Pump LOAD time Max Pump ADD time The maximum load time to fill a cartridge starting from the moment the ink level is into the empty level area. The maximum load time to fill a cartridge starting from the moment the ink level has reached the low level area LOAD Pump speed The pump speed when the ink level is into the empty level area 80 (%) ADD Pump speed The pump speed when the ink level has reached the low level area 30 (%) 22 AP-75201, Rev. 3.0, 12/03/2013

23 Ink level sensor value Ink level area Overflow sensor value Overflow HIGH Max. 90 OK Min. 75 LOW 60 0 EMPTY Notes The time to fill an empty cartridge to its high level is +/- 225 sec. (with speed 80%) The default value is only applicable for BIS systems with Mutoh Mild Solvent ink loaded. For the Mutoh Textile Ink, the cartridges (sensors) have to be calibrated as explained further in this manual. 23 AP-75201, Rev. 3.0, 12/03/2013

24 Automatic Refill Function: To set refill check time. Instructions: Follow the instructions in the table below. IF THEN Mark the Automatic refill function and set the time value in the Automatic refill frame. you want to refill the ink cartridges on a fixed time base Verify the Automatic refill function is unmarked in the Automatic refill frame. you only want a refill of the cartridges when the ink level into the cartridge(s) is low Values: 24 AP-75201, Rev. 3.0, 12/03/2013

25 Automatic refill Parameter Value Default Automatic refill On / Off On Idle time 0 to Example: IF AND THEN the ink level is INTO the OK area Overflow HIGH You marked the Automatic refill function and set the time value in the Automatic refill frame. OK An ink refill will be performed every time the idle time has been expired. LOW EMPTY 25 AP-75201, Rev. 3.0, 12/03/2013

26 2.2.5 Controlling the pumps Caution The BIS system is in IDLE mode and no sensors are used when the pump control mode is activated. Purpose: You can use this function to: Remove all ink from the cartridges flush the ink system with cleaning liquid Use the BIS in the manual mode Switching to the Pump control mode Procedure: Step 1 : Make sure the content of the tab Manual Pump in the main screen is visible. See images below. 26 AP-75201, Rev. 3.0, 12/03/2013

27 Step 2 : Click on the button <Switch to pump control mode> to restart the system in the Pump control mode. See image below. Step 3 : Wait until the BIS has been restarted. Step 4 : Check in the BIS Status frame if the system is in the Pump control mode. See image below. 27 AP-75201, Rev. 3.0, 12/03/2013

28 Controlling the working direction of the pumps Checking working direction Check the working direction of the pumps, it is indicated on the manual pump tab. See image below. Changing working direction: Step 1 : Switch off all the pumps. Step 2 : Click on the <Change the pump direction> button. (See picture below) Step 3 : Switch on the pumps you want to activate. 28 AP-75201, Rev. 3.0, 12/03/2013

29 See further, Controlling the status of the pumps for more info on activating pumps. Notes Only new PCB s are equipped with a change pump direction relay. After start-up, the board version is checked. The change pump direction button will be hidden when an old board is detected. Old boards do not have the change pump direction button; this is detected automatically at start-up. 29 AP-75201, Rev. 3.0, 12/03/2013

30 Controlling the status of the pumps Caution Only 8 pumps are allowed to be running at the same time. Instructions: 1. Check which checkbox corresponds with which pump and 2. Mark the checkboxes of the pumps you want to start pumping. See item below : checkboxes 1. Check which checkbox corresponds with which pump and 2. Unmark the checkboxes of the pumps you want to stop pumping. See item below : checkboxes Notes Check the printer s ink configuration to see which cartridge correspond with which pump. See item below : checkboxes Checkboxes: Notation: Pump cartridge x Checkbox of the pump connected to cartridge x Example: Pump cartridge 1 Checkbox of the pump connected to cartridge 1 30 AP-75201, Rev. 3.0, 12/03/2013

31 Markings: Marking Symbol Status Pump Marked On Pump is working Not marked none Off Pump is not working Location: 31 AP-75201, Rev. 3.0, 12/03/2013

32 Burst options: It is possible to make different settings regarding the pump burst control: Which pumps should burst mark checkbox How long must the pump burst in seconds How long should it stop pumping in seconds Pump speed between 20 and 100 % Pump cartridge check box Burst ON (s) Burst OFF (s) Pump Speed (20%-100%) Result Marked % Continuous pumping at full speed Marked % Continuous pumping at half speed Marked % INVALID changes values to 0 0 Marked % INVALID changes values to 0 0 Continuous pumping at full speed for 10 s Stops pumping for 10 s Marked % Continuous pumping at full speed for 10 s AP-75201, Rev. 3.0, 12/03/2013

33 Switching to the normal functionality mode Caution When you want to switch the pump mode, all pumps need to be switched off! Procedure: Step 1 : Check if all pumps are switched off. (See picture below) Step 2 : Click on the <Switch to Normal mode> in the Manual pump tab. 33 AP-75201, Rev. 3.0, 12/03/2013

34 Step 3 : Wait until the BIS has restarted. Step 4 : Verify if the BIS is in Normal mode. 34 AP-75201, Rev. 3.0, 12/03/2013

35 Example : empty procedure for cartridges Procedure: Step 1 : Switch the BIS to Pump control mode. Refer to: Switching to the Pump control mode for more info. Step 2 : Verify that the BIS is in the reverse pump direction Refer to: Controlling the working direction of the pumps Step 3 : Check which checkbox correspond with the correct pump - cartridge combination. Refer to: Controlling the status of the pumps Checkboxes for more info. Step 4 : Mark the checkbox to start pumping. Step 5 : Unmark the checkbox when the cartridge is empty to stop pumping Step 6 : Switch the BIS to Normal mode Refer to: Switching to the normal functionality mode for more info. Result: After you switched the BIS to Normal functionality mode (step 6 above) the BIS will automatically fill the empty cartridge with ink. 35 AP-75201, Rev. 3.0, 12/03/2013

36 Advanced system information Instructions: Click on the Advanced System information tab to make the content visible. See picture below. This is additional information for the Mutoh Service Technician when encountering problems with the BIS Function: In the advanced system configuration box you can see internal system variables and sensor values. 36 AP-75201, Rev. 3.0, 12/03/2013

37 Parameters and values: Parameter Function Value Cartridge Nr Cartridge indication 1-16 Type sensor Ink type detection Actual value of the type sensor Overflow sensor Overflow level detection Actual value of the overflow sensor RICO value Ink type detection Calculated value for ink type detection Pump time Total working time sec. 37 AP-75201, Rev. 3.0, 12/03/2013

38 Ink type detection (only applicable for Mutoh Mild Solvent BIS systems) IF Type sensor value AND RICO value THEN the ink is detected as < 185 is any value SOLVENT (75 90) > 185 < 70 SOLVENT (75 90) > 185 > 70 WATER BASED ( ) If the ink type is detected wrongly, then a refill procedure has to be performed. Refer to example: Empty procedure for cartridges. Overflow level detection: To set the overflow detection more ore less sensitive, see Ink level conditions 38 AP-75201, Rev. 3.0, 12/03/2013

39 2.3 ADJUSTING SETTINGS Changing the BIS configuration Procedure: Go to Main menu > Configuration (See image below) and choose the correct configuration The configurations are available for following printers. 6 colour printing 6 bottles 8 pumps o o Rockhopper II / universal (spitfire 65/90 Rockhopper 3) with two cleaning cassettes. Viper en viper TX 65 /90 6 Colours 6/ 8 colour printing 8 bottles 8 pumps o o Rockhopper II / universal (Spitfire 65/90 Rockhopper 3) 2x cleaning. Viper en viper TX 65 /90 6 colours+ 2 bottles cleaning / 8 colours 6 colour printing 6 bottle 16 pumps o Spitfire colours + 2x cleaning cassettes 6/8 colour printing 8 bottles 16 pumps o spitfire colours + 2x cleaning bottles 4 colour printing ( 4 heads 8 slots) 4 bottles 8 pumps 39 AP-75201, Rev. 3.0, 12/03/2013

40 o Rockhopper II / universal 65/90 4 colour printing ( 4 heads 8 slots) 8 bottles 8 pumps o Rockhopper II / universal 65/90 4 colour printing ( 8 heads 8 slots) 4 bottles 8 pumps o Rockhopper II 87 / viper 65 /90 viper TX 65/90 4 colour printing ( 8 heads 8 slots) 8 bottles 8 pumps o Rockhopper II 97 / viper 65 /90 viper TX 65 /90 4 colour printing ( 8 heads 16 slots) 4 bottles 8 pumps o Spitfire 100 2x4 configuration 4 colour printing ( 8 heads 16 slots) 8 bottles 16 pumps o Spitfire 100 4x4 configuration. 8 colour printing (8 heads- 16 slots ) 8 bottles 16 pumps o Viper colours 1c => 1h (8heads / 8 slots)- 4 bottles 8 pumps o Blizzard 4 colour 1c -> 1 H(8 heads 16 slots ) 8 bottles 16 pumps o Spitfire 100 extreme. Restart the BIS after changing configuration settings. Notes The pump bottle configuration always remains the same! 40 AP-75201, Rev. 3.0, 12/03/2013

41 2.3.2 Calibrating the ink cartridges (only for Viper and Viper TX!!) Because the three Mutoh Textile inks have a different viscosity and behaviour, the ink cartridges have to be calibrated in order to function well. This calibration consists in setting the minimum, maximum and overflow level of each cartridge. Notes Find below more details on the calibration settings of the Mutoh Textile Inks. For RJ80DS-100 For RJ80DS1-100 For RJ80DS1-500 For RJ80DS-2500 MIN level = approx. 10 mm MAX level = approx. 12 mm MIN level = approx. 10 mm MAX level = approx. 12 mm MIN level = approx. 10 mm MAX level = approx. 12 mm MIN level = approx. 10 mm MAX level = approx. 12 mm Important Do NOT experiment with this setting when working with a BIS system for Rockhopper and Spitfire series printers. I could cause permanent damage for which we are not responsible Before calibration 41 AP-75201, Rev. 3.0, 12/03/2013

42 The PC tool should be in pump control mode and manual ink target level should be activated. Step 1 : Start up the PC tool and set the COM port. Step 2 : Go to the Manual Pump tab and press the following button to switch to pump control mode. Step 3 : Go to the Advanced Settings tab and fill in the password in the lower left corner. The password is the short date in the Regional and Language options menu from Windows. When the password is correct, an extra function will appear ( Use manual ink target levels ). Check this box and change the pump speed as explained in the next chapter. 42 AP-75201, Rev. 3.0, 12/03/2013

43 Select cartridge to calibrate With the up/down button, it is possible to select the cartridge which needs to be calibrated. The current level indicator indicates the current level of the cartridge. Be sure that it is below the minimum level! Notes Note that the value displayed is not the actual millimetres which have to be set. These are readable from the ruler on the ink cartridges Start calibration Step 1 : Insert the first BIS cassette into the cassette slot. Make sure the other cartridges are not yet inserted. This for an easy working flow. Step 2 : Connect the red cable of the cassette to the printer. Step 3 : Fill the cassettes on a high speed (100%) till the ink reaches approximately the 5 mm level. 43 AP-75201, Rev. 3.0, 12/03/2013

44 Step 4 : Lower the speed to % for an accurate calibration. Be sure that the pump speed is higher than 20%. Change the speed in the Manual Pump menu. Step 5 : Press the start button to calibrate the selected cartridge. Step 6 : Press the YES button when the software asks if you are sure. Step 7 : When the cartridge is not empty, a message will appear. It is allowed to press YES when the current ink level is below the minimum ink level (10 mm). If not, change the pump direction (arrows point to bottle) and empty the requested cartridge until its 44 AP-75201, Rev. 3.0, 12/03/2013

45 level is under the minimum level! Change the pump direction again afterwards and continue with the calibration Set the minimum ink level Step 1 : A message will appear after starting the calibration. Press OK to set the minimum ink level. Step 2 : Press the Set Min Target Level button when the ink has reached the minimum ink level which can be read from the ruler on the ink cartridge. 45 AP-75201, Rev. 3.0, 12/03/2013

46 Minimum ink level for Mutoh inks For RJ80DS-100 For RJ80DS-2500 For RJ80DS1-100 For RJ80DS1-500 = 10 mm = 10 mm = 10 mm = 10 mm Step 3 : Step 4 : After pressing the button, the pump will automatically stop. Read out the current level. The value should be lower than 170. If this is not the case, lower the range of the dipswitch. Please refer to the dipswitch table further on in this manual To change the range of the dipswitch, please refer to the chapter Changing the range further on in this manual. Step 5 : Confirm the minimum ink level by pressing yes when asked Set the maximum ink level Step 1 : A message will appear after the minimum level has been set. Press OK to set the maximum ink level. 46 AP-75201, Rev. 3.0, 12/03/2013

47 Step 2 : Press the Set Max Target Level button when the ink has reached the maximum ink level. The maximum ink level can be read from the ruler on the ink cartridge. Maximum ink level for Mutoh inks For RJ80DS-100 For RJ80DS-2500 For RJ80DS1-100 For RJ80DS1-500 = 12 mm = 12 mm = 12 mm = 12 mm Step 3 : After pressing the button, the pump will automatically stop. Step 4 : Read out the current level. The value should be lower than 230 and the difference between the max level and min level should be greater than 25. If this is not the case, change the range of the dipswitch. Notes Lower the range of the dipswitch to 0.0 if the max ink level is larger than 230. If the difference between max en min ink level is smaller than 25, higher the range to 1.0 or 1.1. When changing to a higher range, make sure that the max ink level is not higher than 230. Notes When you set the max ink level, and you have to change the range of the dipswitch in order to fulfil the above requirements, you have to restart the complete calibration for this new range. Notes 47 AP-75201, Rev. 3.0, 12/03/2013

48 To change the range of the dipswitch, please refer to the chapter Changing the range further on in this manual. Step 5 : Confirm the maximum ink level by pressing yes when asked Set cartridge full ink level Step 1 : A message will appear after the maximum level has been set. Press OK to set the cartridge full level. Step 2 : The cartridge full level is the level just before the cartridge will overflow. This level is necessary to know the saturation point of the level sensor. This level is important to limit the up/down boxes in the general monitor window of the BIS. Just before the ink reaches the mechanical overflow, press the Set Cartridge Full Level -button. Step 3 : Confirm the cartridge full level by pressing yes when asked. Step 4 : After pressing the button, the pump will first pump out the surplus of ink till it reaches the max limit. (12mm) then the pump will automatically stop. Step 5 : The calibration for cartridge 1 is done. Step 6 : Calibrate all the cartridges before printing. 48 AP-75201, Rev. 3.0, 12/03/2013

49 Changing the range In this chapter is explained how to change the range of the cassette. There are 4 ranges available. Lower Range 1 2 Range 0.0 both switches are down Range 0.1 The first switch is down, the second one is up. Range 1.0 The first switch is up, the second one is down. Range 1.1 Both switches are up. Higher Range Step 1 : To change the range of your cassette, remove the sticker covering the dipswitch. 49 AP-75201, Rev. 3.0, 12/03/2013

50 Dipswitch Step 2 : Use a pair of tweezers to move the switches up or down. Step 3 : When the range is changed, replace the sticker onto the dipswitch to avoid dust into the switch Stop calibration During the calibration it is possible to terminate the sequence by pressing on the stop button. This action will stop the pumps and the calibration sequence. 50 AP-75201, Rev. 3.0, 12/03/2013

51 2.4 THE HELP MENU Function: You can use this function to retrieve following information: Product Name Application Version Build date Firmware version Terms of use of the software (See image below) 51 AP-75201, Rev. 3.0, 12/03/2013

52

53 3 UPDATING THE FIRMWARE OF THE BIS Read these cautions before updating the BIS! Caution It is necessary to close all running programs before updating to prevent time-out on the serial bus. Caution Do not power down the device after pressing the GO button. Caution If a communication error occurs during programming it will be possible to retry the update sequence. To prevent communications errors during update : - Don t remove the serial cable between the PC and the BIS and - Eliminate interference from other machines (switch off the machines in the surrounding area of the BIS) Function: Use this feature to upgrade your BIS firmware. 53 AP-75201, Rev. 3.0, 12/03/2013

54 Procedure: Step 1 : Go to Main menu > Update (See image below) Step 2 : Close all other programs and click on the <OK> button. (<OK> button on image below) Step 3 : Click the <Load program file> button to browse to a firmware file. See image below. Notes After start-up, a serial speed test is done to check the quality of the serial link. When there is a good speed found, the update can be started and the load program file button is enabled. 54 AP-75201, Rev. 3.0, 12/03/2013

55 Step 4 : Choose the correct BIN file in the Open screen and click on <Open>. See image below. Step 5 : Click the <GO> button (see image below) to update. 55 AP-75201, Rev. 3.0, 12/03/2013

56 56 AP-75201, Rev. 3.0, 12/03/2013

57 Step 6 : Wait until the BIS has been updated completely. A progress bar is shown to see the update status. See image below. Step 7 : Click on the <OK> button (see image below) to restart the device and complete the updating process 57 AP-75201, Rev. 3.0, 12/03/2013

58 This page is intentionally left blank 58 AP-75201, Rev. 3.0, 12/03/2013

59 4 ERROR CODES In the main screen of the BIS PC tool, a window BIS Messages is foreseen. In this window, error messages will be displayed. Please refer to the table below for the different kind of error messages, their explanation and possible solutions. For example ERROR DETECT : 83 INKSYS : 8 PUMP TIMEOUT ERROR Error kind Error number Area Cartridge number Error message Error list Warning/Error message Explanation Solution Warning detect: 8 BIS: No Connector Array DB 15 connector is not connected or broken Check connection Replace connector 59 AP-75201, Rev. 3.0, 12/03/2013

60 Warning detect: 292 bottle: 9 bottle empty Waste bottle is full Empty waste bottle Error detect: 83 inksys: X pump timeout error Pump or pump tubing connected to cartridge X might be broken Ink bottle connected to cartridge X is empty Replace the pump or tubings Fill the bottle with ink Error detect: 41 --> inksys: 4 --> pump driver error Internal pump voltage problem Contact an Authorized Mutoh Technician Reduce the ink level in cartridge X Error detect: 76 inksys: X overflow error Overflow detected on cartridge X Change the general overflow setting when the ink is at a regular level 60 AP-75201, Rev. 3.0, 12/03/2013

61 This page is intentionally left blank 61 AP-75201, Rev. 3.0, 12/03/2013

TECHNICAL INFORMATION BULLETIN

TECHNICAL INFORMATION BULLETIN TECHNICAL INFORMATION BULLETIN Release date: 9 January 2009 Bulletin N : 2009 / 320 FROM: FOR: MUTOH service & support departement AUTHORIZED MUTOH RESELLERS ONLY Spitfire 65/90 Extreme and Rockhopper

More information

Machine Starters Kit

Machine Starters Kit Machine Starters Kit Spitfire 65/90 Extreme Dear Customer, Thank you for buying a Mutoh Spitfire 65/90 Extreme series Printer. This kit contains some tools to make your printer operative. Please refer

More information

Machine Starters Kit

Machine Starters Kit Machine Starters Kit Océ CS9000 Eco-Solvent printer series Dear Customer, Thank you for buying an Océ CS9000 Eco-Solvent printer series. This kit contains some tools to make your printer operative. Please

More information

Manual for MantraJet 1100 CD/DVD auto-printer

Manual for MantraJet 1100 CD/DVD auto-printer Manual for MantraJet 1100 CD/DVD auto-printer Rev 1.03 September 7, 2010 Table of contents Specifications...3 Unpacking MantraJet 1100...4 Quick installation reference MantraJet 1100...7 Installation of

More information

Pitstop Fuel Timer. Operating Manual

Pitstop Fuel Timer. Operating Manual Pitstop Fuel Timer Operating Manual Doug Shelby Engineering Revised: 8/25/2013 Table Of Contents 1. System Description:... 2 2. Software Installation:... 2 3. Hardware Installation:... 2 4. Driver Installation:...

More information

ProJet MJP 35X0 Release Notes

ProJet MJP 35X0 Release Notes ProJet MJP 35X0 Professional 3D Printers Release Notes ProJet 35X0 firmware version 5.13.9889 3D Modeling Accelerator 5.12.9890 305710-N01-33 Rev A Firmware: ProJet 35X0 firmware version 5.13.9889 Software:

More information

UNIVERSAL ENCODING KIT. Installation Guide & User Manual

UNIVERSAL ENCODING KIT. Installation Guide & User Manual UNIVERSAL ENCODING KIT Installation Guide & User Manual Version 6 Release date July 2013 Table Of Contents Chapter 1 Intruduction... 3 Chapter 2 Installation guide... 4 Chapter 3 User guide... 10 Chip

More information

SNC-HMX70. Version Upgrade Guide

SNC-HMX70. Version Upgrade Guide SNC-HMX70 Version Upgrade Guide Rev 1.0.0 Dec 18, 2018 Sony Corporation Revision History # Date Version Changes and comments 1 2018/12/18 1.0.0 initial release 2 3 4 5 6 7 8 2 CONTENTS Introduction...

More information

Temperature logger with display Instruction Manual

Temperature logger with display Instruction Manual LOGGER S0110 Temperature logger with display Instruction Manual Instruction manual for use of temperature logger S0110 Logger is designed for measurement and record of temperature from built-in internal

More information

owncloud Android App Manual

owncloud Android App Manual owncloud Android App Manual Release 2.0.0 The owncloud developers December 14, 2017 CONTENTS 1 Using the owncloud Android App 1 1.1 Getting the owncloud Android App...................................

More information

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins Service Bulletin SB685 Date: 8/18/2017 Subject: TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins Units: All TriPac EVOLUTION Summary: This bulletin updates and

More information

Interpretype Bluetooth Setup Procedure

Interpretype Bluetooth Setup Procedure This information is for configuring the Interpretype to communicate using the Bluetooth Connectivity Kit. To communicate using LAN or Wi-Fi in the full featured version of our software, please refer to

More information

Upgrading Software and Firmware

Upgrading Software and Firmware APPENDIXB This appendix describes how to upgrade or reinstall the Cisco PAM server software, desktop client software, and Gateway module firmware. Contents Upgrade Notes for Release 1.1.0, page B-2 Upgrading

More information

The following simple procedures should be performed prior to testing the 289H M relay card:

The following simple procedures should be performed prior to testing the 289H M relay card: 289H M LSS Installation & Operations Manual Start Up & Test Procedures Chapter 5 INTRODUCTION The information in this section of the manual provides the step by step procedures for conducting any testing

More information

DOT MATRIX PRINTER SP6000 SERIES

DOT MATRIX PRINTER SP6000 SERIES DOT MATRIX PRINTER SP6000 SERIES Hardware Manual < Approval: CEL > Trademark acknowledgments SP6000 : Star Micronics Co., Ltd. Notice All rights reserved. Reproduction of any part of this manual in any

More information

Instruction manual. Printer controller. CP_Manager

Instruction manual. Printer controller. CP_Manager Instruction manual Printer controller CP_Manager Copyright 2013 OKI Data Corporation. All rights reserved. The contents of this manual may be changed without prior notice. Introduction Thank you for purchasing

More information

DPP Micro Reader. The DPP Micro Reader is maintenance-free, not configurable by the user and is operated with a single, multi-function button.

DPP Micro Reader. The DPP Micro Reader is maintenance-free, not configurable by the user and is operated with a single, multi-function button. Read this User Guide completely before using the product. Storage conditions: Store between -20 to 80 C (-4 to 176 F) DPP Micro Reader For use under Emergency Use Authorization (EUA) only. For In Vitro

More information

Calibration Guide. Software Interface Introduction. In Control Pad Tab. Add: add print file. Setting: set parameters and calibrate

Calibration Guide. Software Interface Introduction. In Control Pad Tab. Add: add print file. Setting: set parameters and calibrate Calibration Guide Software Interface Introduction In Control Pad Tab Add: add print file Setting: set parameters and calibrate Online: online / offline switch Home: carriage goes to home position Down

More information

Temperature logger with internal sensor Instruction manual

Temperature logger with internal sensor Instruction manual LOGGER R0110 Temperature logger with internal sensor Instruction manual Manual for use of temperature logger R0110 Logger is designed for measurement and record of temperature from built-in internal temperature

More information

Must read this before installation Important instructions about your CISS system R260 R280 R380 1. If your printer is brand new you must first install the original cartridges that came with your printer.

More information

-Cruise II. Cruise E-Drive Instructions. Lindgaard Pedersen A/S. Rev. 1.0 Page 1 / 13

-Cruise II. Cruise E-Drive Instructions.  Lindgaard Pedersen A/S. Rev. 1.0 Page 1 / 13 -Cruise II ANDROID Cruise E-Drive Instructions LP www.lpdk.com Lindgaard Pedersen A/S Page 1 / 13 Contents This manual contains instructions on the use of the Cruise Android app, as downloaded and installed

More information

Display Manual for icube 2 and 3

Display Manual for icube 2 and 3 Display Manual for icube 2 and 3 Instructions for icube 2: - After switching on the mains switch appears this welcome-site. The print-engine is in the process of priming to get ready. - If switching off

More information

FAC-R Frequency to Analog Converter Installation, Operating & Maintenance Manual

FAC-R Frequency to Analog Converter Installation, Operating & Maintenance Manual COMPANY FAC-R Frequency to Analog Converter Installation, Operating & Maintenance Manual 2017 AW-Lake Company. All rights reserved. Doc ID:FACMAN12082017 V4 Table of Contents Product Overview...3 Operation...3

More information

SMART Coin System QUICK START AND CONFIGURATION GUIDE

SMART Coin System QUICK START AND CONFIGURATION GUIDE SMART Coin System QUICK START AND CONFIGURATION GUIDE SMART Coin System Quick Start and Configuration Guide 2 SMART Coin System Quick Start and Configuration Guide 1 INTRODUCTION 4 2 ASSEMBLY 5 2.1 Detaching

More information

Removal and Installation8

Removal and Installation8 8 Screw Types 8-4 Top Cover Assembly 8-5 Left Hand Cover 8-6 Right Hand Cover 8-10 Front Panel Assembly 8-14 Left Rear Cover 8-15 Right Rear Cover 8-16 Extension Cover (60" Model only) 8-17 Media Lever

More information

Contents Frame Settings Network Settings Display and Volume Time Zone Settings Software Update. 6.6 Advanced Settings

Contents Frame Settings Network Settings Display and Volume Time Zone Settings Software Update. 6.6 Advanced Settings Contents Getting Started Photos, Albums & Playlists 2.1 Create an Album.2 Adding Pictures to an Album 2.3 Mobile App & Email Album.4 Managing your Photos & Albums.5 Connect to Social Media.6 Create a Playlist.7

More information

API A065 series Interfacing Via Bowling/Switch pinsetters (Wins/Focus Scoring System)

API A065 series Interfacing Via Bowling/Switch pinsetters (Wins/Focus Scoring System) API A065 series Interfacing Via Bowling/Switch pinsetters (Wins/Focus Scoring System) Steltronic S.p.A. Via Artigianale 34, 25082 Botticino Sera Brescia - Italy Tel: +39 030 2190811 fax: +39 030 2190798

More information

Upgrading a 1000 Series Printer with MagicLoader

Upgrading a 1000 Series Printer with MagicLoader Upgrading a 1000 Series Printer with MagicLoader Header Videojet Technologies, Inc. Knowledge Article Article Number 000005892 Procedure Upgrading a Printer with MagicLoader Notice MagicLoader software

More information

WSDA User Guide

WSDA User Guide User Guide Version 8500-0029 rev. 006 WSDA -1000 User Guide www.microstrain.com Little Sensors, Big Ideas. 2012 by 459 Hurricane Lane, Suite 102 Williston, VT 05495 Phone 802-862-6629 Fax 802-863-4093

More information

ictp Gen 3 mainboard replacement Short guide to ensure successful replacement of the mainboard on PW 3000/8000 imaging engine

ictp Gen 3 mainboard replacement Short guide to ensure successful replacement of the mainboard on PW 3000/8000 imaging engine ictp Gen 3 mainboard replacement Short guide to ensure successful replacement of the mainboard on PW 3000/8000 imaging engine 1 List of actions Back-up the old settings Access the main board Remove and

More information

MS Word MS Outlook Mailbox Maintenance

MS Word MS Outlook Mailbox Maintenance MS Word 2007 MS Outlook 2013 Mailbox Maintenance INTRODUCTION... 1 Understanding the MS Outlook Mailbox... 1 BASIC MAILBOX MAINTENANCE... 1 Mailbox Cleanup... 1 Check Your Mailbox Size... 1 The Quota

More information

Manual. LC-16 system. LC-16 Inkjet Printer 1

Manual. LC-16 system. LC-16 Inkjet Printer 1 Manual LC-16 system LC-16 Inkjet Printer 1 Index ENVIRONMENT. 3 OPERATOR S SAFETY 3 OPERATION SAFETY 3 PART 1 INSTALLATION AND PARAMETER SETTING 4 1) Preparing 4 2) Installation 4 3) Priming 4 4) Parameter

More information

Aqueous GPC Instructions - Detailed

Aqueous GPC Instructions - Detailed Aqueous GPC Instructions - Detailed Waste Bottle Columns PL Datastream Injection Port GPC Computer UV Detector GPC Pump Eluent Bottle The Aqueous GPC Set Up RI Detector Important The points below must

More information

Continuous Ink Supply System for Canon ip4000 Printer. Installation Instruction

Continuous Ink Supply System for Canon ip4000 Printer. Installation Instruction Continuous Ink Supply System for Canon ip4000 Printer Installation Instruction For TL Ink Pre-filled Version The whole operation is very easy. It s really an effective tool to save your money. CIS for

More information

Pacific Sun Kore 5. Intelligent Doser

Pacific Sun Kore 5. Intelligent Doser Pacific Sun Kore 5 th Intelligent Doser Connection ports 1.a Connecting to your computer Kore 5th dosers are controlled using a Bluetooth connection between doser and your computer. It is highly recommended

More information

AIRNET 54Mb b/g High Power USB Adapter. User s Manual

AIRNET 54Mb b/g High Power USB Adapter. User s Manual AIRNET 54Mb 802.11b/g High Power USB Adapter User s Manual FCC Certifications Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits

More information

SCD Live SPEED TECH A/S

SCD Live SPEED TECH A/S SPEED TECH A/S Nybrovej 97. DK2820 Gentofte. Phone: +45 45938545 Fax: +45 45938544 www.doorcontrol.dk - info@speed-tech.dk Contents: SCD Live 1 INTRODUCTION... 3 1.1 DESCRIPTION... 3 1.2 DISCLAIMER...

More information

MailEnable Connector for Microsoft Outlook

MailEnable Connector for Microsoft Outlook MailEnable Connector for Microsoft Outlook Version 1.41 This guide describes the installation and functionality of the MailEnable Connector for Microsoft Outlook. Features The MailEnable Connector for

More information

Dual channel temperature logger with display Instruction Manual

Dual channel temperature logger with display Instruction Manual LOGGER S0122 Dual channel temperature logger with display Instruction Manual ie-log-s0122-05 Instruction manual for use of temperature logger S0122 Logger is designed for measurement and record of ambient

More information

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation. Embedded Modbus TCP Module GS11-MT User Manual REV 1.1 SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 About the Embedded Module... 4 1.1 General...4 1.2 Features... 4 1.3 Specifications...4

More information

EL731 PROFIBUS INTERFACE

EL731 PROFIBUS INTERFACE Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/el731 EL731 PROFIBUS INTERFACE Revision 0-A-032816 Copyright 2016 Littelfuse Startco All rights reserved. Document Number: PM-1011-EN

More information

User Guide. Gateway Driver for Control4 Composer Pro. Version 1.0.5

User Guide. Gateway Driver for Control4 Composer Pro. Version 1.0.5 User Guide Gateway Driver for Control4 Composer Pro Version 1.0.5 Contents User Guide Gateway Driver for Control4 Composer Pro Version 1.0.5 Introduction... 2 Driver Version and File Name... 2 Adding and

More information

ibidi PumpControl Instruction Manual Version 1.5.0

ibidi PumpControl Instruction Manual Version 1.5.0 ibidi PumpControl Instruction Manual Version 1.5.0 II ibidi GmbH 2011, version 1.5.0, revision 2, 2011-10-26, Andreas Rainer Table of contents 1 General Information... 1 1.1 System Requirements... 1 1.2

More information

P-Bus Gateway Firmware

P-Bus Gateway Firmware P-Bus Gateway Firmware PBGW2.128 Version 1.40 Easy configuration with web interface (HTML) P-busses configurable separately in master or slave mode Status display of each P-bus Fixed IP address or dynamic

More information

Operator Manual for Profibus

Operator Manual for Profibus PROCESS ANALYSERS SERVOPRO MultiExact Operator Manual for Profibus Part Number: Revision: Language: 05410007A 0 UK English This page intentionally blank LIST OF CONTENTS Section Page 1. DESCRIPTION AND

More information

PLC LCD BA. SPS LCD SL /10.07 /US I SN

PLC LCD BA. SPS LCD SL /10.07 /US I SN Computer Control CX PLC LCD BA. SPS LCD SL /10.07 /US I SN 712147 The contents are correct to the best of our knowledge and belief and correspond to the present level of technology. No legal claims can

More information

Wireless Advisor Advanced Pedestrian System (WiAAPS) Common Procedures

Wireless Advisor Advanced Pedestrian System (WiAAPS) Common Procedures Wireless Advisor Advanced Pedestrian System (WiAAPS) Common Procedures Table of Contents 1 Introduction... 2 2 Accessing the Webpage... 3 3 Swapping Out a WiAPB... 4 4 Swapping Out a WiAPC... 7 5 Adding

More information

Veho VPA-001-QUDO USER MANUAL. Exploring your Qudo

Veho VPA-001-QUDO USER MANUAL. Exploring your Qudo Veho VPA-001-QUDO USER MANUAL Exploring your Qudo 1 2 3 4 5 1 6 7 8 9 10 11 12 13 No Description 1 Holding the frame in Landscape: Move left button 2 On/Off Switch 3 SD Card Slot 4 USB Port 5 Charging

More information

INDEX. Network Power Monitor R10 SNMP

INDEX. Network Power Monitor R10 SNMP Innovative Electronics for a Changing World NPM-R10 Remote Network Power Monitor With optional relay board and GSM module INDEX Amended 21 March 2017: Add user defined Password see page 13 Add wire Connection

More information

MantraJet 1100 CD/DVD autoprinter Operator s manual

MantraJet 1100 CD/DVD autoprinter Operator s manual MantraJet 1100 CD/DVD autoprinter Operator s manual Rev 1.00 May 7, 2008 Table of contents 1. Specifications.. Page 2 2. Unpacking you MantraJet 1100 Page 3 3. Using your autoprinter for the first time.

More information

MailEnable Connector for Microsoft Outlook

MailEnable Connector for Microsoft Outlook MailEnable Connector for Microsoft Outlook Version 1.36 This guide describes the installation and functionality of the MailEnable Connector for Microsoft Outlook. Features The MailEnable Connector for

More information

Smart Sign System. Installation & Setup Instructions

Smart Sign System. Installation & Setup Instructions Smart Sign System Installation & Setup Instructions This page intentionally left blank. Smart Sign and Sign Control Software Installation and Setup Instructions Table of Contents Section 1 Section 2 Section

More information

Innovative Electronics for a Changing World INDEX

Innovative Electronics for a Changing World INDEX Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.

More information

APC-100. IEEE g Wireless USB Adapter. User s Guide v1.0

APC-100. IEEE g Wireless USB Adapter. User s Guide v1.0 APC-100 IEEE 802.11g Wireless USB Adapter User s Guide v1.0 FCC Certifications Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits

More information

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1 CLIQ Web Manager User Manual V 6.1 The global leader in door opening solutions Program version: 6.1 Document number: ST-003478 Date published: 2016-03-31 Language: en-gb Table of contents 1 Overview...9

More information

For Auto Locksmith Association only!!! Emergency Service Manual.

For Auto Locksmith Association only!!! Emergency Service Manual. For Auto Locksmith Association only!!! Emergency Service Manual = OBD Key Programmer + OBD Alarm Disarming tool = ====================================================================== Models: AUDI A4

More information

User s Manual. ASE-1019 ASE Light Source

User s Manual. ASE-1019 ASE Light Source ASE-1019 ASE Light Source ASE-1019 ASE Light Source User s Manual Triple Play Communications Document 3013800-701 250 East Drive, Suite F Rev 1.1 Melbourne, FL 32904 July 2015 1 Revision History Document

More information

Troubleshooting with the LCD Error Message Table

Troubleshooting with the LCD Error Message Table Troubleshooting with the LCD Error Message Table LCD Error Message Cause Solution Calibrate Failed No. 155 and 170) Calibrate Film No. 159) Calibrate Ribbon Nos. 128 and 170) Card Feed Stop No. 137) Card

More information

Scheduling Module Client Booking Quick Guide Online-Scheduling

Scheduling Module Client Booking Quick Guide Online-Scheduling Scheduling Module Last Updated: November 26, 2009 System Administration Contact: Colin Bryant Phone: 604-822-7374 E-mail: PsychIT@exchange.ubc.ca Logon to Book King Enter the following URL into your address

More information

Installing the Tibbo Device Server Toolkit

Installing the Tibbo Device Server Toolkit Ethernet Time Clock Tibbo Software Installation and Configuration V5.7 for Windows Vista and Windows 7 When using the Icon Time Systems PROX or PIN Entry Employee Time Clocks with Ethernet capabilities,

More information

Dual channel temperature logger with two binary inputs and LCD display Instruction Manual

Dual channel temperature logger with two binary inputs and LCD display Instruction Manual LOGGER S0841 Dual channel temperature logger with two binary inputs and LCD display Instruction Manual Instruction Manual for use of S0841 logger Instrument is designed for measurement and record of temperature

More information

SuperPremiumElectronics.com

SuperPremiumElectronics.com Must read this before installation Important instructions about your CISS system HP10/11 1. If your printer is brand new you must first install the original cartridges that came with your printer. The

More information

User Manual. Thermo Scientific Orion

User Manual. Thermo Scientific Orion User Manual Thermo Scientific Orion Orion Star Com Software Program 68X637901 Revision A April 2013 Contents Chapter 1... 4 Introduction... 4 Star Com Functions... 5 Chapter 2... 6 Software Installation

More information

Page 1 MRK-D-0011, V2.0 Aeroqual SM50 User Guide

Page 1 MRK-D-0011, V2.0 Aeroqual SM50 User Guide Page 1 Table of Contents User Guide Revision History... 3 Description... 4 1. Operating Instructions... 4 1.1. Power... 4 1.2. Warm Up... 4 1.3. Standard Inputs and Outputs... 4 1.4. Using the Relay Output...

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 E39.0.31.6C-02 Data logger for humidity temperature as of version V1.0 Operating Manual T-Logg 160 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0 +49 (0) 9402

More information

Tube Washing Upgrade Guide. for Epson SureColor F2000

Tube Washing Upgrade Guide. for Epson SureColor F2000 Tube Washing Upgrade Guide for Epson SureColor F2000 2016 guides.equipmentzone.com Page 1 of 14 Part 1 -How to Upgrade Epson F2000 Firmware Open your internet browser Select address bar located up top

More information

MobileFast SyncStudio. A Complete Mobile Database Synchronization Solution. Quick-Start Manual. Release 1.61, May 2014

MobileFast SyncStudio. A Complete Mobile Database Synchronization Solution. Quick-Start Manual. Release 1.61, May 2014 MobileFast SyncStudio A Complete Mobile Database Synchronization Solution Quick-Start Manual Release 1.61, May 2014 Copyright 2014 by MobileFast Corporation All rights reserved Page 1 of 25 Edition Notes

More information

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series INSTALLATION & OPERATING GUIDE Rev. B P/N 3321515 www.securakeystore.com (800) 878-7829 sales@securakeystore.com COPYRIGHT 2001

More information

USB 3.0 to 4K DP Adapter. User's Manual

USB 3.0 to 4K DP Adapter. User's Manual USB 3.0 to 4K DP Adapter User's Manual Table of Contents SAFETY INSTRUCTIONS... 1 COPYRIGHT... 1 TRADEMARKS... 1 REGULATORY COMPLIANCE... 2 FCC CONDITIONS... 2 CE... 2 WEEE INFORMATION... 2 INTRODUCTION...

More information

Configurator 2.0 Software

Configurator 2.0 Software Configurator 2.0 Software QUICK REFERENCE MANUAL Super Systems Inc. 7205 Edington Drive Cincinnati, OH 45249 513-772-0060 / 800-666-4330 Fax: 513-772-9466 www.supersystems.com Table of Contents SSi Configurator

More information

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin: Phase Loss Protection Upgrade In this bulletin: Introduction... 2 Purpose... 2 General... 2 Applicability... 2 HD3070 Phase Loss Protection Upgrade Kit Parts... 2 Preparation... 4 Install the Phase Loss

More information

Windows user guide for version 3.3

Windows user guide for version 3.3 1 Windows user guide for version 3.3 2 Contents 1. Installation...4 1.1. How to install BABEL on your Windows desktop...4 2. Getting started...5 2.1. First run...5 2.2. Password setup...5 2.3. Key import...5

More information

LE840/LE850. Printer Setting Tool Manual Technical Reference

LE840/LE850. Printer Setting Tool Manual Technical Reference LE840/LE850 Printer Setting Tool Manual Technical Reference Table of Contents 1. INTRODUCTION 1 SUPPORTED PRINTERS... 1 FEATURES... 1 OUTLINE OF THE FUNCTIONS... 2 NOTATION... 2 SCREENS USED IN THIS DOCUMENT...

More information

NOTIFY PLUS - MY SERVICES MANAGEMENT

NOTIFY PLUS - MY SERVICES MANAGEMENT Set Up Fee...$50 51-250 Phone Book Entries...$9.95/mo. 1-50 Phone Book Entries...$ 4.95/mo. 251-1000 Phone Book Entries...$19.95/mo. LOGIN TO MY SERVICES In your web browser type in myservices.gondtc.com.

More information

GOLANDER PUMP BQ80S Microflow Variable-Speed Peristaltic Pump Operation Manual

GOLANDER PUMP BQ80S Microflow Variable-Speed Peristaltic Pump Operation Manual GOLANDER PUMP BQ80S Microflow Variable-Speed Peristaltic Pump Operation Manual info@golanderpump.com http://golanderpump.com 1-678-587-8806 Contents 1 Safety Cautions... 1 2 Introduction... 1 3 Functions

More information

Z CAM K1 Pro. User Manual (Draft) v1.0

Z CAM K1 Pro. User Manual (Draft) v1.0 Z CAM K1 Pro User Manual (Draft) v1.0 1. INTRODUCTION Camera Introduction Display Information LED Indicator Status Green: When the camera is turned on with SD card in the slot. Red: When the camera is

More information

User Manual Australia

User Manual Australia User Manual Australia April 2009 EAZ0057B06A Rev. A Trademarks Acknowledgements Snap-on, ShopStream Connect, ETHOS, MODIS, SOLUS, SOLUS PRO, and Vantage PRO are trademarks of Snap-on Incorporated. All

More information

Safety Instructions 1-1 Avoid unintended Start General Description 2-2

Safety Instructions 1-1 Avoid unintended Start General Description 2-2 Contents Contents 1 Safety and precautions 1-1 Safety Instructions 1-1 Avoid unintended Start. 1-1 2 Introduction 2-1 General Description 2-2 3 Supported Configuration 3-1 Introduction 3-1 Fixed-speed

More information

HiTi P310W. user manual V_0.1.

HiTi P310W. user manual V_0.1. HiTi P310W user manual www.hiti.com V_0.1 TABLE OF CONTENTS Chapter 1. Important Safety Instruction Environments 1-1 Handling Instruction 1-2 Handling Instruction for Consumable and Printed Output 1-3

More information

SOFTWARE MANUAL PHOENIX AC DRIVE DX & EX DRIVEMASTER

SOFTWARE MANUAL PHOENIX AC DRIVE DX & EX DRIVEMASTER SOFTWARE MANUAL PHOENIX AC DRIVE DX & EX DRIVEMASTER TABLE OF CONTENTS i SECTION TITLE PAGE 1.0 Introduction 1-1 2.0 Initial Setup 2-1 3.0 Main Menu 3-1 4.0 Configuring the Communications 4-1 5.0 Upload/Download

More information

DS400 / DS404. Software Installation and Operations Manual. DS400 Docking Station. (800) (734)

DS400 / DS404. Software Installation and Operations Manual. DS400 Docking Station. (800) (734) DS400 / DS404 33 Docking Stations Software Installation and Operations Manual DS400 Docking Station DS404 Multi-inlet Docking Station 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734)

More information

ProJet 3600 ProJet 35X0

ProJet 3600 ProJet 35X0 ProJet 3600 ProJet 35X0 Professional 3D Printers Release Notes ProJet 3600 firmware version 6.3.7972 ProJet 35X0 firmware version 5.9.7889 3D Modeling Accelerator 5.9.7973 305710-N01-33 Rev A Firmware:

More information

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual LOGGER S0541 Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual Instruction Manual for use of S0541 logger Instrument is designed for measurement and record of temperature

More information

Installation of the PCMeasure Movement Sensor (30114)

Installation of the PCMeasure Movement Sensor (30114) 1. Hardware: Installation of the PCMeasure Movement Sensor (30114) Connect the sensor to a serial or parallel port of the PC using one of the PCMeasure adaptors, or directly to the PCMeasure Ethernet Box.

More information

EEG DE361 HD BAS Decoder Product Manual

EEG DE361 HD BAS Decoder Product Manual EEG DE361 HD BAS Decoder Product Manual All rights reserved. [This page left intentionally blank] eeg Table Of Contents Introduction 2 Product Description... 2 Installation 3 Front Panel... 3 Rear Panel...

More information

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO DeviceNet/PROFIBUS-DP Adapter - User Manual REV 4.0 SiboTech Automation Co., Ltd. Technical Support: +86-21-5102 8348 E-mail:gt@sibotech.net Table of Contents 1 ABOUT THIS DOCUMENT...2 1.1 GENERAL... 2

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E E39.0.0X.6C-03 Data logger for temperature as of version V1.3 Operating Manual T-Logg 100 T-Logg 100 T-Logg 100 E GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0

More information

GmbH, Stettiner Str. 38, D Paderborn

GmbH, Stettiner Str. 38, D Paderborn AnDi 1 to AnDi 4 A/D Converter for M-Bus (Valid from M-Bus generation: $31) Art. no. MB AnDi 1 Art. no. MB AnDi 2 Art. no. MB AnDi 3 Art. no. MB AnDi 4 1 channel A/D converter for M-Bus 2 channel A/D converter

More information

Sygonix Home Starter Kit

Sygonix Home Starter Kit App Instruction Manual Sygonix Home Starter Kit Item No. 1597114 www.conradconnect.de Contents Conrad Connect... 4 Symbols... 4 Core functions... 5 App to device communication... 6 App Installation...

More information

ARES. User s Guide. Aprilia Racing Engine Setup. English version

ARES. User s Guide. Aprilia Racing Engine Setup. English version ARES Aprilia Racing Engine Setup User s Guide English version ARES user s guide 2/59 I. WARNINGS... 6 II. SOFTWARE AND ENGINE CONFIGURATION COMPATIBILITY... 6 III. BEFORE UPDATING ARES TO A NEWER VERSION...

More information

ProCS Product Configuration Software

ProCS Product Configuration Software ProCS Product Configuration Software Rev. D Jupiter Avionics Corporation 1959 Kirschner Road Kelowna BC V1Y 4N7 Canada Tel: +1 778 478 2232 Toll-Free: 1 855 478 2232 www.jupiteravionics.com Copyright 2013

More information

Contents for How to Use the Simulator Program

Contents for How to Use the Simulator Program SPAU 341 C Contents for How to Use the Simulator Program This manual describes the various items you see in the simulation program. To choose a Help Topic, click on the underlined topic to view the text.

More information

Although Netafim takes the greatest possible care both with its products and the associated manuals, there may be discrepancies in them.

Although Netafim takes the greatest possible care both with its products and the associated manuals, there may be discrepancies in them. Document Update Revision Description of Change Change Date Approval Number Draft Original Version 0000 20090702 P.Bail Application PoleNet RadioNet Host RadioNet Base RadioNet Remote NMC Pro Version V1.61

More information

Microsoft Windows 10. Quick Reference. Watsonia Publishing 47 Greenaway Street Bulleen VIC 3105 Australia

Microsoft Windows 10. Quick Reference. Watsonia Publishing 47 Greenaway Street Bulleen VIC 3105 Australia Watsonia Publishing 47 Greenaway Street Bulleen VIC 3105 Australia www.watsoniapublishing.com info@watsoniapublishing.com Quick Reference Course Code: INF1440 Table of Contents Chapter 1: Starting With

More information

CLOUDING WIRELESS MANAGED CPE/AP OUTDOOR 2.4GHZ WL-CPE2G24-065

CLOUDING WIRELESS MANAGED CPE/AP OUTDOOR 2.4GHZ WL-CPE2G24-065 CLOUDING WIRELESS MANAGED CPE/AP OUTDOOR 2.4GHZ WL-CPE2G24-065 USER MANUAL REV.310517 Thanks for choosed our product INDEX General Warning CHAPTER 1 How to connect and charge the outdoor CPE 1.1 CPE s

More information

NV12 QUICK START AND CONFIGURATION GUIDE

NV12 QUICK START AND CONFIGURATION GUIDE NV12 QUICK START AND CONFIGURATION GUIDE NV12 Quick Start and Configuration Guide 2 NV12 Quick Start and Configuration Guide 1 INTRODUCTION 4 2 ASSEMBLY 5 2.1 Bezel Fitting and Removal 5 2.2 Removing the

More information

NORDSON CORPORATION AMHERST, OHIO USA

NORDSON CORPORATION AMHERST, OHIO USA CanWorks Operator Interface Tracking PLUS for CanWorks Systems with SM-2 Spray Monitors User Guide Part 1018132A NORDSON CORPORATION AMHERST, OHIO USA 2002 Nordson Corporation. All rights reserved. CanWorks,

More information

If you experience issues at any point in the process, try checking our Troublshooting guide.

If you experience issues at any point in the process, try checking our Troublshooting guide. Follow along with this guide to set up your Omega2 for the first time. We ll first learn how to properly connect your Omega to a Dock and power it up. Then we ll connect to it to use the Setup Wizard to

More information

USER S GUIDE CONTENTS

USER S GUIDE CONTENTS USER S GUIDE CONTENTS INTRODUCTION... 1 PACKAGE CONTENTS... 2 TECHNICAL FEATURES... 3 CENTRAL UNIT DESCRIPTION... 5 INSTALLATION... 8 CAUTION... 8 Mounting the central unit... 8 Hardware installation steps...

More information

NKL Edge Software User Manual

NKL Edge Software User Manual NKL Edge Software User Manual Version 2.0 Created 09/30/09 Table of Contents 1 Introduction... 1 2 PC Hardware and OS Requirements... 2 3 Software Installation and Activation... 3 4 Setting up a Lantronix

More information