System Board D2786 for RX200 S5. Technical Manual

Size: px
Start display at page:

Download "System Board D2786 for RX200 S5. Technical Manual"

Transcription

1 System Board D2786 for RX200 S5 Technical Manual Edition April 2009

2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by to Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2009 FujitsuTechnologySolutionsGmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.

3 Contents 1 Introduction Important notes Notes on safety CE certificate of conformity Environmental protection Features Overview Main memory PCI slots Screen resolution Temperature / system monitoring Connectors and indicators System board Connector panel Jumpers and switches Replacing the lithium battery Abbreviations D2786 (RX200 S5) Technical Manual

4

5 1 Introduction This technical manual describes the system board D2786, which is equipped with one or two Intel processors. Further information you will find in the "BIOS Setup. For additional driver information, refer to the Readme files located on the server hard disk and on the supplied CDs or DVDs. Notational conventions The meanings of the symbols and fonts used in this manual are as follows: Text in talics Text in fixed font Text in semi-bold fixed font [Key symbol] "Quotation marks" Ê V CAUTION! I indicates commands or menu items. indicates system output on the monitor. indicates values to be entered through the keyboard. indicates keys according to their representation on the keyboard. If capital letters are to be entered explicitly, then the Shift key is shown, e.g. [SHIFT] - [A] for A. If two keys need to be pressed at the same time, then this is shown by placing a hyphen between the two key symbols. indicate names of chapters and terms that are being emphasized. describes activities that must be performed in the order shown. describes activities that must be performed in the order shown. indicates additional information, notes and tips. Table 1: Notational conventions D2786 (RX200 S5) Technical Manual 5

6

7 2 Important notes In this chapter you will find essential information regarding safety when working with your server. V CAUTION! With the system board installed you must open the system to access the system board. How to access the system board of your system is described in the appropriate service supplement. When handling the system board, refer to the specific notes on safety in the operating manual and/or service supplement for the respective server. 2.1 Notes on safety V CAUTION! The actions described in these instructions should only be performed by authorized, qualified personnel. Equipment repairs should only be performed by qualified staff. Any failure to observe the guidelines in this manual, and any unauthorized openings and improper repairs could expose the user to risks (electric shock, fire hazards) and could also damage the equipment. Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability. Transport the device only in the antistatic original packaging or in packaging that protects it from knocks and jolts. Only install expansions that are allowed for the system board. If you install other expansions, you may damage the requirements and rules governing safety and electromagnetic compatibility or your system. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. D2786 (RX200 S5) Technical Manual 7

8 Notes on safety Important notes V CAUTION! Components can become very hot during operation. Ensure you do not touch components when making extensions to the system board. There is a danger of burns! Transmission lines to peripheral devices must be adequately shielded. To the LAN wiring the requirements apply in accordance with the standards EN and EN /2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 Mbit/s Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC are to be considered. Never connect or disconnect data transmission lines during a storm (risk of lightning hazard). Batteries V CAUTION! Incorrect replacement of lithium battery may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer. It is essential to observe the instructions in the chapter Replacing the lithium battery. 8 Technical Manual D2786 (RX200 S5)

9 Important notes Notes on safety Modules with electrostatic-sensitive components Boards with electrostatic sensitive devices (ESD) are marked with the following label: Figure 1: ESD label When you handle components fitted with ESDs, you must observe the following points under all circumstances: You must always discharge yourself of static charges (e.g. by touching a grounded object) before touching the components. The equipment and tools you use must be free of static charges. Shut-down the system and remove the power plug from the power socket before inserting or removing boards containing ESDs. Always hold boards with ESDs by their edges. Never touch pins or conductors on boards fitted with ESDs. Use a grounding cable designed for this purpose to connect yourself to the system unit as you install/deinstall the board. Place all components on a static-free surface. I You will find a detailed description for handling ESD components in the relevant European or international standards (EN , ANSI/ESD S20.20). D2786 (RX200 S5) Technical Manual 9

10 CE certificate of conformity Important notes Notes about boards During installation/deinstallation of the board, observe the specific instructions described in the service supplement for the respective server. before you make modifications on an installed board. To prevent damage to the board, the components and conductors on it, please take great care when you insert or remove boards. Take great care to ensure that extension boards are slotted in straight, without damaging components or conductors on the board, or any other components, for example EMI spring contacts. Be careful with the locking mechanisms (catches, centring pins etc.) when you replace the system board or components on it, for example memory modules or processors. Never use sharp objects (screw drivers) for leverage. 2.2 CE certificate of conformity The board complies with the requirements of the EC directives 2004/108/EC regarding Electromagnetic Compatibility and 2006/95/EC Low Voltage Directive. This is indicated by the CE marking (CE = Communauté Européenne). Compliance was tested in a typical PRIMERGY configuration. 10 Technical Manual D2786 (RX200 S5)

11 Important notes Environmental protection 2.3 Environmental protection Environmentally friendly product design and development This product has been designed in accordance with standards for environmentally friendly product design and development. This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account. This saves resources and thus reduces the harm done to the environment. Energy-saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work. Packaging information Do not throw away the packaging. You may need it later for transporting the system. If possible, the equipment should only be transported in its original packaging. Information on handling consumables Please dispose of batteries in accordance with local regulations. In accordance with EU directives, batteries must not be disposed of with unsorted domestic waste. They can be returned free of charge to the manufacturer, dealer or an authorized agent for recycling or disposal. All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants: Cd Cadmium Hg Mercury Pb Lead Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them. D2786 (RX200 S5) Technical Manual 11

12 Environmental protection Important notes Returns, recycling and disposal The device must not be disposed of with domestic waste. This device is labeled in compliance with European directive 2002/96/EG on waste electrical and electronic equipment (WEEE). This directive sets the framework for returning and recycling used equipment and is valid across the EU. When returning your used device, please use the return and collection systems available to you. Further information can be found at Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu Technology Solutions branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D Paderborn Tel Fax Technical Manual D2786 (RX200 S5)

13 3 Features 3.1 Overview Processors 2 processor sockets LGA or 2 x Intel Dual or Quad-Core or LV processors of the Nehalem-EP line with power consumption up to 95 W quick path interconnects (QPI) integrated memory controller Main memory 12 slots for main memory; each CPU supports 3 channels with 2 DIMM slots UDIMM (unbuffered DIMM) or DDIMM (registered DIMM) memory modules: capacity UDIMMs: 1 GB or 2 GB capacity RDIMMs: 2 GB, 4 GB or 8 GB minimum memory configuration: one DIMM with independent channel mode maximum 96 GB (with RDIMMs) or 24 GB (with UDIMMs) of memory ECC multiple bit error detection and single bit error correction memory scrubbing function Single Device Data Correction (SDDC) function (Chipkill ), only with RDIMMs memory mirroring function memory sparing function Chips on the system board Intel Tylersburg 24D chipset Intel IOH (north bridge) Intel ICH10R (south bridge) dual-port 1Gbit Ethernet LAN controllers Intel 82575EB D2786 (RX200 S5) Technical Manual 13

14 Overview Features onboard irmc S2 Server Management Controller with integrated graphics controller and associated service LAN connector Flash EPROM for: BIOS LAN Server Management (SM) Internal connectors 1x SATA connector with 4 ports (hard disk drives) 1x SATA connector (optical disk drive) 1x connector for UFM 1x main power connector 1x power supply monitoring and controlling connector 6x system fan monitoring and controlling connectors 1x connector for the front side video port 1x front panel connector 1x connector for TPM External connectors Rear side 1x serial interface (COM) 3x USB connectors 1x VGA connector 2x RJ45 LAN connectors 1x RJ45 service LAN connector Front side 3x USB connectors 1x VGA connector 14 Technical Manual D2786 (RX200 S5)

15 Features Overview PCI slots There are three PCI expansion slots on the system board: 2x PCI Express x8 expansion slots 1x PCI Express x4 expansion slot (mechanical x8) Power management ACPI (states S0, S1, S5) 3.3 V standby power on the PCI Express slots on/off/sleep/wake by power button on/off by software wake on by RTC, external serial port, LAN, PCI Express controller and irmc S2 power on by power button, external serial port, LAN, PCI Express controller and irmc S2 BIOS features Phoenix SecureCore TM Server BIOS, version 6.0 SMBIOS 2.50 (DMI) MultiProcessor Specification 1.4 Server Hardware Design Guide 3.0 WfM 2.0 IPMI V2.0 ACPI 2.0 support USB keyboard/mouse boot possible from: CD-ROM USB drive LAN (PXE and iscsi) console redirection support OEM logo CPU, memory disable memory mirroring and memory sparing support Environmental protection Battery in holder Form factor 431 x 717 mm D2786 (RX200 S5) Technical Manual 15

16 Overview Features CSS (Customer Self Service) This system board supports the CSS functionality. You will find a description of CSS functionality in the operating manual of your server. USB Flash Module (option) The system board can be equipped with an USB Flash Module (UFM) by the manufacturer or by an add-on kit. The module can be used as optional memory for software (e.g. VMware) or as a software dongle. TPM (option) The system board can be equipped with a TPM (Trusted Platform Module) by the manufacturer or by an add-on kit. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption). The TPM is activated via the BIOS system (for more information, refer to the BIOS manual). V CAUTION! When using the TPM, note the program descriptions provided by the third party manufacturers. You must also create a backup of the TPM content. To do this, follow the third party manufacturer's instructions. Without this backup, if the TPM or the system board is faulty you will not be able to access your data. If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content. 16 Technical Manual D2786 (RX200 S5)

17 Features Main memory 3.2 Main memory The 12 slots (6 for each CPU) for main memory are designed for RDIMM (registered DIMM, capacities: 2, 4 and 8 GB) as well as for UDIMM (unbuffered DIMM, capacities: 1 and 2 GB) memory modules. The maximum main memory is for installing UDIMM memory modules 24 GB, for installing RDIMM memory modules 96 GB. Mixing both types of memory modules is forbidden. ECC with memory scrubbing and with the Single Device Data Correction (SDDC) function (only with RDIMMs) is supported. I You will find the descriptions how to install memory modules in the Options Guide of your server. DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU 2 CPU 1 DIMM 2D DIMM 1D DIMM 2E DIMM 1E DIMM 2F DIMM 1F Figure 2: Slots of the main memory D2786 (RX200 S5) Technical Manual 17

18 Main memory Features Module population Minimum main memory configuration is 1 DIMM with Independent Channel Mode. It is possible to mix memory modules with different clock rates. The lowest clock rate will be applied to the system. Single and dual-rank memory modules can be mixed, quad-rank memory modules have to be used exclusively. Mix of modules with different capacity is possible bank-wise (2x2) with Mirror or Spare Mode. The assignment of the DIMM slots to the banks and channels is printed on the system board. Possible population in different modes: Independent Channel Mode Mirrored Channel Mode Performance Channel Mode Spare Channel Mode DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU 1 DIMM 1C DIMM 1C DIMM 1C CPU 2 DIMM 2C CPU 2 DIMM 2C CPU 2 DIMM 2C CPU 2 DIMM 1B DIMM 1B DIMM 1B DIMM 2D DIMM 2B DIMM 2D DIMM 2B DIMM 2D DIMM 2B DIMM 2D DIMM 1D DIMM 1A DIMM 1D DIMM 1A DIMM 1D DIMM 1A DIMM 1D DIMM 2E DIMM 2A DIMM 2E DIMM 2A DIMM 2E DIMM 2A DIMM 2E DIMM 1E DIMM 1E DIMM 1E DIMM 1E DIMM 2F CPU 1 DIMM 2F CPU 1 DIMM 2F CPU 1 DIMM 2F DIMM 1F DIMM 1F DIMM 1F DIMM 1F Legend: required optional, same type in bank per CPU not used required, if 2nd CPU is configured optional, any type Figure 3: Possible population in different modes Independent Channel Mode Allows population of all channels in any order. Related to the channels (A-F) DIMM1 must be populated first. Works with DIMMs of different clock rates and applies the lowest clock rate. Works with UDIMMs as well as RDIMMs. 18 Technical Manual D2786 (RX200 S5)

19 Features Main memory Mirrored Channel Mode Requires identical modules on the channels A & B (CPU 1) and on D & E (CPU 2). Half of the capacity is used for the mirroring only the half of the installed main memory is available for the applications. Channel C (CPU 1) respectively channel F (CPU 2) are not available in this mode. RDIMMs are supported. Performance Channel Mode Requires identical modules on all channels of each bank per CPU. RDIMMs are supported. Spare Channel Mode Requires identical modules on all channels of each bank per CPU. One third of the capacity is used as spare range this means the main memory for the applications is reduced to two third. RDIMMs are supported. D2786 (RX200 S5) Technical Manual 19

20 PCI slots Features 3.3 PCI slots JP2 Front VGA UFM PWR CTRL S1 irmc JP5 SATA1 Slot 2 Slot 1 2 Battery DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A Slot CPU 1 Figure 4: PCI slots PCI slot Description 1 PCI Express x8 (standard profile, half-length) 2 PCI Express x8 (low profile, half-length) 3 PCI Express x4 - mechanically x8 (low profile, half-length) 20 Technical Manual D2786 (RX200 S5)

21 Features Screen resolution Expansion cards are integrated on the system board using a riser card. The riser card provides one slot at an angle of 90 to the system board. The following riser cards are available: Riser card with one standard half length PCI Express expansion x8 slot Riser card with one low-profile half length PCI Express expansion x8 slot Riser card with one low-profile half length PCI Express expansion x4 slot (mechanically: x8), reserved for modular RAID option. 3.4 Screen resolution Depending on the operating system used the screen resolutions in the following table refer to the screen controller on the system board. If you are using an external screen controller, you will find details of supported screen resolutions in the operating manual or technical manual supplied with the controller. Screen resolution Refresh rate (Hz) Max. number of colours 640x bit 800x bit 1024x bit 1152x bit 1280x bit 1600x bit D2786 (RX200 S5) Technical Manual 21

22 Temperature / system monitoring Features 3.5 Temperature / system monitoring Temperature and system monitoring aim to reliably protect the computer hardware against damage caused by overheating. In addition, any unnecessary noise is also prevented by reducing the fan speed, and information is provided about the system status. The temperature and system monitoring are controlled by the irmc S2 controller (integrated Remote Management Controller). The following functions are supported: Temperature monitoring Measurement of the processor temperature, measurement of the ambient temperature by a temperature sensor. Measurement of the memory module temperature by a temperature sensor on the depending memory module. Fan monitoring Fans that are no longer available, blocked or sticky fans are detected. Fan control The fans are controlled according to the temperature. Sensor monitoring The removal of, or a fault in, a temperature sensor is detected. Should this happen all fans monitored by this sensor run at maximum speed, to achieve the greatest possible protection of the hardware. Voltage monitoring When voltage exceeds warning level high or falls below warning level low, an entry in the SEL will be generated. If the corresponding agents are installed, also an alert will be generated. System Event Log (SEL) All monitored events of the system board are signalised via the Global Error LED and recorded in the System Event Log. They could be retrieved in the BIOS Setup or via the ServerView Operations Manager. 22 Technical Manual D2786 (RX200 S5)

23 Features Connectors and indicators 3.6 Connectors and indicators System board Front Panel Fan 1/2 SATA ODD Indicate CSS button Fan 3/4 Fan 5/6 S1 Front VGA TPM Slot 2 Slot 1 SATA1 Slot3 Fan 7/8 Fan 9/10 Fan 11/12 5 PWR 4 3 PWR CTRL CPU 2 DIMM 2D DIMM 1D DIMM 2E DIMM 1E DIMM 2F DIMM 1F 2 UFM JP5 DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU JP2 irmc Figure 5: Internal connectors of the system board D2786 D2786 (RX200 S5) Technical Manual 23

24 Connectors and indicators Features No. Print Description 1 CN7 Connector for the front side video port 2 CN10 Connector for USB Flash Module 3 CN1 PSU I 2 C connector 4 CN11 SATA1 HDD connector (4 ports) 5 CN13 PSU main connector 6 SATA2 SATA ODD connector 7 CN2 Connector for front panel 8 JP4, JP6, JP7, JP10, JP11, JP12 System fan connectors 9 CN30 Connector for TPM 24 Technical Manual D2786 (RX200 S5)

25 Features Connectors and indicators Front Panel PWR Fan 1/2 SATA ODD Indicate CSS button 1 S1 JP2 irmc Slot 2 Slot 1 TPM Front VGA UFM JP5 Slot3 PWR CTRL SATA1 Fan 3/4 Fan 5/6 DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU 1 CPU 2 DIMM 2D DIMM 1D DIMM 2E DIMM 1E DIMM 2F DIMM 1F Fan 7/8 Fan 9/10 Fan 11/12 Figure 6: Indicators on the system board and indicate CSS button D2786 (RX200 S5) Technical Manual 25

26 Connectors and indicators Features No. Description 1 Indicate CSS button LEDs A, B and C are visible from outside on the rear of the server. All the other LEDs are only visible, if the cover of the server has been opened. Meaning of the LEDs LED Indicator Meaning A - GEL (Global Error LED) B - CSS yellow (Customer Self yellow flashing Service) C - Identification blue orange indicates a prefailure orange flashing indicates a failure. Reasons for a failure may be: - a sensor detects an error - sensor defect - fan defect - CPU error - Software detected an error indicates a prefailure indicates a failure server is identified via the ServerView Operations Manager D - Controller orange controller failure E - CPU orange CPU failure F - system/fans green fan okay orange fan failure G - memory orange memory module failure H - irmc S2 green flashing irmc S2 okay If the server has been powered off (power-plugs must be disconnected) it is possible to indicate the faulty component by pressing the indicate CSS button. It is required that the server has been without power no longer than 24 hours. 26 Technical Manual D2786 (RX200 S5)

27 Features Connectors and indicators Connector panel Figure 7: Connector panel No. Description 1 USB connectors 2 Global error indicator (orange), CSS indicator (yellow), ID indicator (blue); (description see preceding section) 3 Service LAN connector (for irmc S2 server management function) 4 Video connector 5 Serial interface COM 6 GbE LAN connector 2 7 GbE LAN connector 1 (also for irmc S2 server management function) LAN connectors The system board is equipped with a dual-port Gigabit Ethernet Controller of the type Intel 82575EB. Each LAN controller port supports transmission rates of 10 Mbit/s, 100 Mbit/s and 1 Gbit/s. The LAN controller ports also support WOL functionality by means of Magic Packet. It is also possible to start a system via a LAN without a separate boot hard disk drive. PXE is supported here. The separate service LAN connector is used as a management interface (irmc S2) and is prepared for operation with the Remote Management. Optionally LAN connector 1 can also be used for irmc S2 server management. Each LAN connector has two LEDs which display the speed of the connection and its status: D2786 (RX200 S5) Technical Manual 27

28 Connectors and indicators Features Figure 8: LAN indicators No Indicator Description 1 LAN activity (service LAN) 2 LAN transfer rate (service LAN) 3 LAN activity (standard LAN) 4 LAN transfer rate (standard LAN) Steady green signal when a LAN connection exists. Remains dark when no LAN connection exists. Flashes green when LAN transfer takes place. Steady green signal in the event of a LAN transfer rate of100 Mbps. Remains dark in the event of a LAN transfer rate of 10 Mbps. Steady green signal when a LAN connection exists. Remains dark when no LAN connection exists. Flashes green when LAN transfer takes place. Flashes yellow in the event of a LAN transfer rate of 1 Gbps Steady green signal in the event of a LAN transfer rate of 100 Mbps. Remains dark in the event of a LAN transfer rate of 10 Mbps. 28 Technical Manual D2786 (RX200 S5)

29 Features Connectors and indicators Jumpers and switches JP2 Front VGA UFM PWR CTRL S1 irmc JP5 SATA1 Slot 2 Slot 3 Battery Slot 1 DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU 1 Figure 9: Jumpers and switches I The default setting for all jumpers is position 1-2. D2786 (RX200 S5) Technical Manual 29

30 Connectors and indicators Features Clear CMOS - jumper JP2 Jumper Pos. Description 1-2 Normal, not clear CMOS settings (default setting). 2-3 Clear CMOS settings and restore default values (hardware). Proceed as follows to delete the CMOS settings: Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Create a backup of all the data. Shut down the server. Remove all power and connection cables. Remove the housing cover. If necessary, remove the expansion card which hinders access to jumper JP2 (Clear CMOS). Remove jumper JP2 from position 1-2 and insert it in position 2-3 for 20 to 30 seconds. Insert jumper JP2 in position 1-2 again. Reinsert the expansion card. Close the server s housing cover. Connect all the power and connection cables again. Switch the server on again. During the POST process press [F2] in order to enter the Setup Utility. Press [F9] to set the system defaults. Press [F10] to save your changes and to exit the Setup Utility. 30 Technical Manual D2786 (RX200 S5)

31 Features Connectors and indicators Protect RTC - jumper JP5 Jumper Pos. Description 1-2 Normal operation (default setting) 2-3 Clear ME_RTC REG System configuration switches S1 I The default setting for all switches is off. Switches Function Status Description S1-1 BIOS recovery On Boot block enabled Off Normal boot S1-2 Skip BIOS On Password disabled password query Off Password enabled S1-3 BIOS writeprotect S1-4 CMOS clear (software) On Off On Off BIOS can only be read BIOS can both be read and written to Clear CMOS settings and restore system defaults Normal CMOS settings D2786 (RX200 S5) Technical Manual 31

32

33 4 Replacing the lithium battery In order to save the system information over a long period, a lithium battery is installed to provide the CMOS-memory with a current. When the charge is too low or the battery is empty, a corresponding error message is provided. The lithium battery must then be replaced. V The lithium battery must be replaced with an identical battery or a battery type recommended by the manufacturer (CR2032). Do not throw lithium batteries into the trash can. It must be disposed of in accordance with local regulations concerning special waste. Make sure that you insert the battery the right way round. The plus pole must be on the top! Figure 10: Replacing the lithium battery Ê Press the locking spring into direction of the arrow (1), so that the lithiumbattery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). D2786 (RX200 S5) Technical Manual 33

34

35 Abbreviations The technical terms and abbreviations given below represent only a selection of the full list of common technical terms and abbreviations. Not all technical terms and abbreviations listed here are valid for the described system board. ACPI Advanced Configuration and Power Interface ASR&R Automatic Server Recovery and Restart ATA BBU BIOS BMC Advanced Technology Attachment Battery Backup Unit Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM CRU CSS CPU COMmunication port Customer Replaceable Unit Customer Self Service Central Processing Unit D2786 (RX200 S5) Technical Manual 35

36 Abbreviations DDR Double Data Rate DIMM Dual In-line Memory Module DIP DMI DMA Dual In-line Package Desktop Management Interface Direct Memory Access DRAM Dynamic Random Access Memory ECC Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic ESD Electrostatic Discharge EVRD Enterprise Voltage Regulator Down FBD HDD Fully Buffered DIMM Hard Disk Drive 36 Technical Manual D2786 (RX200 S5)

37 Abbreviations HPC ICE IDE IME IOOP IPMB IPMI irmc LAN LED MCH MPS NMI NOS Hot-plug Controller In Circuit Emulation Integrated (intelligent) Drive Electronics Integrated Mirror Enhanced Intelligent Organization Of PCI Intelligent Platform Management Bus Intelligent Platform Management Interface integrated Remote Management Controller Local Area Network Light Emitting Diode Memory Controller Hub Multi Processor Specification Non Maskable Interrupt Network Operating System D2786 (RX200 S5) Technical Manual 37

38 Abbreviations NVRAM Non Volatile RAM ODD OEM OHCI OS PCI PDA PIO PLD Optical Disc Drive Original Equipment Manufacturer Open Host Controller Interface Operating System Peripheral Components Interconnect Prefailure Detection and Analyzing Programmed Input Output Programmable Logic Device POST Power-On Self Test PS(U) Power Supply (Unit) PWM PXE Pulse Wide Modulation Preboot execution Environment RAID Redundant Array of Inexpensive Disks 38 Technical Manual D2786 (RX200 S5)

39 Abbreviations RAM RSB RST RTC SAS SATA SCSI Random Access Memory Remote Service Board ReSeT Real Time Clock Serial Attached SCSI Serial ATA Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide SHPC Standard Hot Plug Controller SMB SMM SMP System Management Bus Server Management Mode Symmetrically Multi Processing D2786 (RX200 S5) Technical Manual 39

40 Abbreviations TPM UFM UHCI USB VGA VRD VRM WfM WOL Trusted Platform Module USB Flash Module Unified Host Controller Interface Universal Serial Bus Video Graphics Adapter Voltage Regulator Down Voltage Regulator Module Wired for Management Wake up On LAN 40 Technical Manual D2786 (RX200 S5)

System Board D3031 for PRIMERGY RX200 S6

System Board D3031 for PRIMERGY RX200 S6 Technical Manual - English System Board D3031 for PRIMERGY RX200 S6 Technical Manual Edition August 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

System Board D3034 for PRIMERGY RX100 S7

System Board D3034 for PRIMERGY RX100 S7 Technical Manual - English System Board D3034 for PRIMERGY RX100 S7 Technical Manual Edition August 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

System Board D2799 for PRIMERGY TX200 S6

System Board D2799 for PRIMERGY TX200 S6 Technical Manual - English System Board D2799 for PRIMERGY TX200 S6 Technical Manual Edition July 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

System Board D2870 for PRIMERGY RX600 S5

System Board D2870 for PRIMERGY RX600 S5 Technical Manual - English System Board D2870 for PRIMERGY RX600 S5 Technical Manual April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY SX650 Storage Blade. Operating Manual

PRIMERGY SX650 Storage Blade. Operating Manual PRIMERGY SX650 Storage Blade Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

System Board D2785 for TX120 S2. Technical Manual

System Board D2785 for TX120 S2. Technical Manual System Board D2785 for TX120 S2 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC) User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Last Edition August 2017 Comments Suggestions Corrections The User Documentation Department would

More information

PRIMERGY BX920 S1 Server-Blade. Service Supplement

PRIMERGY BX920 S1 Server-Blade. Service Supplement PRIMERGY BX920 S1 Server-Blade Service Supplement Edition April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY TX120 S2 Server. Service Supplement

PRIMERGY TX120 S2 Server. Service Supplement PRIMERGY TX120 S2 Server Service Supplement Edition July 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

System Board D2619 for RX/TX300 S5. Technical Manual

System Board D2619 for RX/TX300 S5. Technical Manual System Board D2619 for RX/TX300 S5 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Standard server node for PRIMERGY CX400 M1 multi-node server system

More information

System Board D2559 for TX150 S6. Technical Manual

System Board D2559 for TX150 S6. Technical Manual System Board D2559 for TX150 S6 Technical Manual Edition November 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

Fujitsu PRIMERGY TX100 S2 Server

Fujitsu PRIMERGY TX100 S2 Server Datasheet Fujitsu PRIMERGY TX100 S2 Server Enter the world of servers - now with 0-Watt functionality PRIMERGY TX industry standard tower servers: efficient, rock solid, record-breaking performance. PRIMERGY

More information

System Board D2671 for RX200 S4. Technical Manual

System Board D2671 for RX200 S4. Technical Manual System Board D2671 for RX200 S4 Technical Manual Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY BX620 S3 2-way Server Blade

PRIMERGY BX620 S3 2-way Server Blade PRIMERGY PRIMERGY BX620 S3 2-way Server Blade Options Guide Walter Dick Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 52 51)14888-12 Fax:

More information

PRIMERGY TX120 S2 Server. Operating manual

PRIMERGY TX120 S2 Server. Operating manual PRIMERGY TX120 S2 Server Operating manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY RX300 S5. Operating manual

PRIMERGY RX300 S5. Operating manual PRIMERGY RX300 S5 Operating manual Edition september 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY RX300 S5. Service Supplement

PRIMERGY RX300 S5. Service Supplement PRIMERGY RX300 S5 Service Supplement Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY RX300 S2 Server System

PRIMERGY RX300 S2 Server System PRIMERGY PRIMERGY RX300 S2 Server System Monika Spanjaart Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001160 Fax: (++49) 700 / 372 00000

More information

Baseboard D3144, CPUMEMR D3145, PCIR D3146 for PRIMERGY RX900 S2

Baseboard D3144, CPUMEMR D3145, PCIR D3146 for PRIMERGY RX900 S2 Technical Manual - English Baseboard D44, MEMR D45, PCIR D46 for PRIMERGY RX9 S Technical Manual Edition May Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

Fujitsu PRIMERGY BX920 S1 Dual-Socket Server

Fujitsu PRIMERGY BX920 S1 Dual-Socket Server Datasheet Fujitsu PRIMERGY BX920 S1 Dual-Socket Server Blade All-around server blade packing lots of computing power in small form factor. The PRIMERGY BX Blade Servers are the ideal choice for data center

More information

PRIMERGY RX200 S5. Operating Manual

PRIMERGY RX200 S5. Operating Manual PRIMERGY RX200 S5 Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

NEC Express5800/R120e-1M System Configuration Guide

NEC Express5800/R120e-1M System Configuration Guide NEC Express5800/R120e-1M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server Expandable all-round server for

More information

PRIMERGY BX922 S2 Server Blade

PRIMERGY BX922 S2 Server Blade Options Guide - us PRIMERGY BX922 S2 Server Blade Options Guide Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

Data Sheet Fujitsu PRIMERGY TX1330 M2 Server

Data Sheet Fujitsu PRIMERGY TX1330 M2 Server Data Sheet Fujitsu PRIMERGY TX1330 M2 Server Expandable all-round server for SMEs PRIMERGY TX1330 M2 The FUJITSU Server PRIMERGY TX1330 M2 is the ideal robust, expandable, and cost-efficient server for

More information

Altos T310 F3 Specifications

Altos T310 F3 Specifications Product overview The Altos T310 F3 delivers proactive management tools matched by best priceperformance technology ideal for SMB and branch office operations. This singlesocket tower server features an

More information

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server Expandable all-round server for SMEs PRIMERGY TX1330 M1 The PRIMERGY TX1330 M1 is the

More information

PRIMERGY RX300 S4. Options Guide

PRIMERGY RX300 S4. Options Guide PRIMERGY RX300 S4 Options Guide Edition June 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

Modular RAID Controllers

Modular RAID Controllers User Guide - English Modular RAID Controllers "RAID 0/1 SAS based on LSI MegaRAID" "RAID 5/6 SAS based on LSI MegaRAID" "RAID Ctrl SAS 6G 0/1 (D2607)" "RAID Ctrl SAS 6G 5/6 512MB (D2616)" "PY SAS RAID

More information

PRIMERGY BX630 S2 Scalable Server Blade. Operating Manual

PRIMERGY BX630 S2 Scalable Server Blade. Operating Manual PRIMERGY BX630 S2 Scalable Server Blade Operating Manual Edition October 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

PRIMERGY TX120 Server. Operating Manual

PRIMERGY TX120 Server. Operating Manual PRIMERGY TX120 Server Operating Manual Edition July 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY CX122 S1 Server

PRIMERGY CX122 S1 Server Operating Manual - English PRIMERGY CX122 S1 Server Operating Manual Edition November 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Acer AR320 F2 Specifications

Acer AR320 F2 Specifications Acer AR320 F2 Specifications What Product overview The AR320 F2 single-socket server delivers great performance and enterprise-level scalability in a space-saving design. Proactive management utilities

More information

Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade

Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade Universal dual socket server blade with high computing and I/O performance in a small form factor The PRIMERGY BX Blade Servers are the ideal

More information

NEC Express5800/R120d-2M Configuration Guide

NEC Express5800/R120d-2M Configuration Guide NEC Express5800/R120d-2M Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper

More information

Data Sheet ESPRIMO P2550. Your immediately available Office PC ESPRIMO P2550

Data Sheet ESPRIMO P2550. Your immediately available Office PC ESPRIMO P2550 Data Sheet Your immediately available Office PC Issue: October 2009 The is designed for price-conscious customers and is equipped with state-of-the-art standard Intel technology. These systems meet every

More information

System board D2004 for RX100 S3

System board D2004 for RX100 S3 PRIMERGY System board D2004 for RX100 S3 Technical manual Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49) 700

More information

Fujitsu PRIMERGY BX960 S1 Quad socket server

Fujitsu PRIMERGY BX960 S1 Quad socket server Datasheet Fujitsu PRIMERGY BX960 S1 Quad socket server blade Datasheet for Red Hat certification Dynamics paired with high scaling The PRIMERGY BX Blade Servers are the ideal choice for data center solutions

More information

PRIMERGY Econel 200 S2 Server. Operating manual

PRIMERGY Econel 200 S2 Server. Operating manual PRIMERGY Econel 200 S2 Server Operating manual Edition March 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

Altos R320 F3 Specifications. Product overview. Product views. Internal view

Altos R320 F3 Specifications. Product overview. Product views. Internal view Product overview The Altos R320 F3 single-socket 1U rack server delivers great performance and enterprise-level scalability in a space-saving design. Proactive management utilities effectively handle SMB

More information

Acer AT310 F2 Specifications

Acer AT310 F2 Specifications Product overview The AT310 F2 delivers proactive manageability tools matched by best price-performance technology ideal for SMB and branch office business operations. This single-socket tower server also

More information

RS500-E6/PS4. Configuration Guide

RS500-E6/PS4. Configuration Guide RS500-E6/PS4 Configuration Guide E4332 First Edition V1 February 2009 Copyright 2009 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in

More information

MITAC Desktop Board PD10TI Product Guide

MITAC Desktop Board PD10TI Product Guide MITAC Desktop Board PD10TI Product Guide Desktop Board Features This chapter briefly describes the main features of MITAC Desktop Board PD10TI. Table 1 summarizes the features of the Desktop Board. TABLE

More information

MITAC Desktop Board PD12TI Product Guide

MITAC Desktop Board PD12TI Product Guide MITAC Desktop Board PD12TI Product Guide Desktop Board Features This chapter briefly describes the main features of MITAC Desktop Board PD12TI. Table 1 summarizes the features of the Desktop Board. Table

More information

Data Sheet Fujitsu PRIMERGY RX4770 M2 Server

Data Sheet Fujitsu PRIMERGY RX4770 M2 Server Data Sheet Fujitsu PRIMERGY RX4770 M2 Server Data Sheet Fujitsu PRIMERGY RX4770 M2 Server Platform of choice for business critical backend services with superior levels of performance and reliability enhanced

More information

CAF-1000 Series Communication Appliance. User s Manual Revision: 1.0

CAF-1000 Series Communication Appliance. User s Manual Revision: 1.0 CAF-1000 Series Communication Appliance User s Manual Revision: 1.0 CE This certificate of conformity of COS-0906 series with actual required safety standards in accordance with 89/366 ECC-EMC Directive

More information

Data Sheet Fujitsu PRIMERGY TX100 S3 Server

Data Sheet Fujitsu PRIMERGY TX100 S3 Server Data Sheet Fujitsu PRIMERGY TX100 S3 Server Enter the world of PRIMERGY TX servers PRIMERGY TX tower servers are ideal for use in SMEs or branch offices. They increase operational efficiency by providing

More information

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Strong Performance and Cluster

More information

PRIMERGY RX200 S4 Server. Operating manual

PRIMERGY RX200 S4 Server. Operating manual PRIMERGY RX200 S4 Server Operating manual Edition January 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

GW2000h w/gw175h/q F1 specifications

GW2000h w/gw175h/q F1 specifications Product overview The Gateway GW2000h w/ GW175h/q F1 maximizes computing power and thermal control with up to four hot-pluggable nodes in a space-saving 2U form factor. Offering first-class performance,

More information

D2709 BIOS Setup Utility for PRIMERGY TX200 S5. Reference Manual

D2709 BIOS Setup Utility for PRIMERGY TX200 S5. Reference Manual D2709 BIOS Setup Utility for PRIMERGY TX200 S5 Reference Manual Edition May 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

D2786 BIOS Setup Utility for PRIMERGY RX200 S5. Reference Manual

D2786 BIOS Setup Utility for PRIMERGY RX200 S5. Reference Manual D2786 BIOS Setup Utility for PRIMERGY RX200 S5 Reference Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

Data Sheet Fujitsu PRIMERGY RX300 S7 Dual socket 2 U rack server

Data Sheet Fujitsu PRIMERGY RX300 S7 Dual socket 2 U rack server Data Sheet Fujitsu PRIMERGY RX300 S7 Dual socket 2 U rack server Data Sheet Fujitsu PRIMERGY RX300 S7 Dual socket 2 U rack server Datasheet for Red Hat certification The versatile 2U powerhouse PRIMERGY

More information

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191V2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet: http://www.ipcomm.de

More information

PRIMERGY TX200 S4 Server. Operating manual

PRIMERGY TX200 S4 Server. Operating manual PRIMERGY TX200 S4 Server Operating manual Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

PRIMERGY BX924 S2 Server Blade

PRIMERGY BX924 S2 Server Blade Operating Manual - English PRIMERGY BX924 S2 Server Blade Operating Manual Edition May 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Acer AT110 F2 Specifications

Acer AT110 F2 Specifications Product overview The AT110 F2 delivers true server-class features and expandability along with best price-performance technology to assure the success of your small-sized business. This single-socket tower

More information

PRIMERGY BX620 S6 Server Blade

PRIMERGY BX620 S6 Server Blade Service Supplement - English PRIMERGY BX620 S6 Server Blade Service Supplement September 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY SX940 S1 Storage Blade

PRIMERGY SX940 S1 Storage Blade Operating manual - English PRIMERGY SX940 S1 Storage Blade Operating manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

Data Sheet FUJITSU Server PRIMERGY RX300 S8 Dual socket 2U rack server

Data Sheet FUJITSU Server PRIMERGY RX300 S8 Dual socket 2U rack server Data Sheet FUJITSU Server PRIMERGY RX300 S8 Dual socket 2U rack server Data Sheet FUJITSU Server PRIMERGY RX300 S8 Dual socket 2U rack server The versatile 2U powerhouse FUJITSU Server PRIMERGY systems

More information

Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node

Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node Datasheet for Red Hat certification Standard server node for PRIMERGY

More information

Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade

Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade Datasheet for Red Hat certification High-end server blade with

More information

Cisco MCS 7835-H2 Unified Communications Manager Appliance

Cisco MCS 7835-H2 Unified Communications Manager Appliance Cisco MCS 7835-H2 Unified Communications Manager Appliance Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks enabling easy collaboration

More information

PRIMERGY CX400 S1 Server Enclosure

PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual - English PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual Edition December 2012 Comments Suggestions Corrections The User Documentation Department would

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

NEC Express5800/B120e-h System Configuration Guide

NEC Express5800/B120e-h System Configuration Guide NEC Express5800/B120e-h System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191C2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de

More information

Installation ServerView ESXi CIM Provider V6.12

Installation ServerView ESXi CIM Provider V6.12 Installation Guide - English FUJITSU Software ServerView Suite Installation ServerView ESXi CIM Provider V6.12 VMware vsphere Hypervisor server (ESXi) as of version 4.0 Edition August 2017 Comments Suggestions

More information

FUJITSU Server PRIMERGY RX100 S8

FUJITSU Server PRIMERGY RX100 S8 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX100 S8 Upgrade and Maintenance Manual April 2015 Comments Suggestions Corrections The User Documentation Department would like to know

More information

System board D2020 for Econel 200

System board D2020 for Econel 200 Produktfamilie System board D2020 for Econel 200 Technical manual Redakteur Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-??? Fax: (++49)

More information

Data Sheet Fujitsu PRIMERGY TX100 S2 Server

Data Sheet Fujitsu PRIMERGY TX100 S2 Server Data Sheet Fujitsu PRIMERGY TX100 S2 Server Enter the world of TX servers - now with 0-Watt functionality PRIMERGY TX tower servers are ideal for use in SMEs or branch offices. They increase operational

More information

PRIMERGY Econel 230R S1 Server. Operating manual

PRIMERGY Econel 230R S1 Server. Operating manual PRIMERGY Econel 230R S1 Server Operating manual Edition May 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

HP ProLiant DL360 G7 Server - Overview

HP ProLiant DL360 G7 Server - Overview Menu Hewlett Packard Enterprise Support Center Search Notifications Help Settings HP ProLiant DL360 G7 Server - Overview Product description What's new Product features Software overview Important links

More information

NEC Express5800/R120h-2M System Configuration Guide

NEC Express5800/R120h-2M System Configuration Guide NEC Express5800/R120h-2M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Acer AR320 F1 specifications

Acer AR320 F1 specifications Product overview The AR320 F1 is a single-socket server that delivers great performance and enterprise-level scalability in a space-saving design. Driven by a robust processor, huge memory footprint, and

More information

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments.

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments. The IBM System x3500 M4 server provides outstanding performance for your business-critical applications. Its energy-efficient design supports more cores, memory, and data capacity in a scalable Tower or

More information

PRIMERGY RX600 S4 Server. Service Supplement

PRIMERGY RX600 S4 Server. Service Supplement PRIMERGY RX600 S4 Server Service Supplement Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY SX910 S1 Storage Blade

PRIMERGY SX910 S1 Storage Blade Operating Manual - English PRIMERGY SX910 S1 Storage Blade Operating Manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

FUJITSU Server PRIMERGY RX1330 M2

FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual December 2015 Comments Suggestions Corrections The User Documentation Department would like to

More information

PRIMERGY BX620 S2 2-way Server Blade

PRIMERGY BX620 S2 2-way Server Blade PRIMERGY PRIMERGY BX620 S2 2-way Server Blade Operating Manual Walter Dick Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (05251)8-14854 Fax:

More information

NEC Express5800/B120d-h System Configuration Guide

NEC Express5800/B120d-h System Configuration Guide NEC Express5800/B120d-h System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Data Sheet Fujitsu PRIMERGY BX924 S3 Dual Socket Server Blade

Data Sheet Fujitsu PRIMERGY BX924 S3 Dual Socket Server Blade Data Sheet Fujitsu PRIMERGY BX924 S3 Dual Socket Server Blade High-end server blade with maximum scalability for demanding applications Fujitsu PRIMERGY BX Blade Servers provide a faster, simpler and lower-cost

More information

PRIMERGY TX200 S3 Server. Operating Manual

PRIMERGY TX200 S3 Server. Operating Manual PRIMERGY TX200 S3 Server Operating Manual Edition June 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY BX920 S2 Server Blade

PRIMERGY BX920 S2 Server Blade Operating Manual - English PRIMERGY BX920 S2 Server Blade Operating Manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

Data Sheet Fujitsu PRIMERGY TX1310 M1 Server

Data Sheet Fujitsu PRIMERGY TX1310 M1 Server Data Sheet Fujitsu PRIMERGY TX1310 M1 Server Data Sheet Fujitsu PRIMERGY TX1310 M1 Server The ideal first server PRIMERGY TX1310 M1 The Fujitsu PRIMERGY TX1310 M1 is the ideal first server for small and

More information

PRIMERGY BX900 Server Blades

PRIMERGY BX900 Server Blades PRIMERGY BX900 Server Blades System configurator and order-information guide March 2010 Contents Instructions Configuration diagram Configurator 0 System software 10 X BX920 S1 Dual Socket 20 11 XI Processor

More information

PRIMERGY BX924 S2. System configurator and order-information guide September PRIMERGY Server. Contents

PRIMERGY BX924 S2. System configurator and order-information guide September PRIMERGY Server. Contents PRIMERGY BX924 S2 System configurator and order-information guide September 2012 Contents Instructions Configuration diagram Configurator # X BX924 S2 Dual Socket 20 # XI Processor 21 # XII Storage # XIII

More information

(Please refer "CPU Support List" for more information.)

(Please refer CPU Support List for more information.) CPU 1. Support for 7 th and 6 th generation Intel Core i7 processors/ Intel Core i5 processors/intel Core i3 processors/ Intel Pentium processors/intel Celeron processors in the LGA1151 package 2. L3 cache

More information

Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade

Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade High-end server blade with maximum scalability for demanding applications

More information

DIVAR IP 2000 DIP N, DIP HD, DIP HD. en Quick Installation Guide

DIVAR IP 2000 DIP N, DIP HD, DIP HD. en Quick Installation Guide DIVAR IP 2000 DIP-2040-00N, DIP-2042-2HD, DIP-2042-4HD en Quick Installation Guide DIVAR IP 2000 Table of Contents en 3 Table of contents 1 Safety precautions 4 1.1 General safety precautions 4 1.2 Electrical

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

NEC Express5800/B120f-h System Configuration Guide

NEC Express5800/B120f-h System Configuration Guide NEC Express5800/B120f-h System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Data Sheet FUJITSU Server PRIMERGY BX920 S4 Dual Socket Server Blade

Data Sheet FUJITSU Server PRIMERGY BX920 S4 Dual Socket Server Blade Data Sheet FUJITSU Server PRIMERGY BX920 S4 Dual Socket Server Blade Data Sheet FUJITSU Server PRIMERGY BX920 S4 Dual Socket Server Blade Mainstream dual-socket server blade for essential enterprise workloads

More information

Cisco MCS 7845-H1 Unified CallManager Appliance

Cisco MCS 7845-H1 Unified CallManager Appliance Data Sheet Cisco MCS 7845-H1 Unified CallManager Appliance THIS PRODUCT IS NO LONGER BEING SOLD AND MIGHT NOT BE SUPPORTED. READ THE END-OF-LIFE NOTICE TO LEARN ABOUT POTENTIAL REPLACEMENT PRODUCTS AND

More information

Data Sheet Fujitsu PRIMERGY RX100 S7p Mono socket 1 U rack server

Data Sheet Fujitsu PRIMERGY RX100 S7p Mono socket 1 U rack server Data Sheet Fujitsu PRIMERGY RX100 S7p Mono socket 1 U rack server Data Sheet Fujitsu PRIMERGY RX100 S7p Mono socket 1 U rack server Small in size and low in cost rich in optional features The PRIMERGY

More information

ServerView Archive Manager

ServerView Archive Manager User Guide - English ServerView Suite ServerView Archive Manager ServerView Operations Manager as of V5.0 Edition February 2018 Comments Suggestions Corrections The User Documentation Department would

More information

Cisco MCS 7816-H3. Supported Cisco Applications. Key Features and Benefits

Cisco MCS 7816-H3. Supported Cisco Applications. Key Features and Benefits Cisco MCS 7816-H3 Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables more effective, more secure, more personal

More information

PRIMERGY RX600 S5 Server

PRIMERGY RX600 S5 Server Service Supplement - English PRIMERGY RX600 S5 Server Service Supplement June 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

ZOTAC ZBOX. User s Manual

ZOTAC ZBOX. User s Manual User s Manual ZOTAC ZBOX No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language

More information