System Board D3031 for PRIMERGY RX200 S6

Size: px
Start display at page:

Download "System Board D3031 for PRIMERGY RX200 S6"

Transcription

1 Technical Manual - English System Board D3031 for PRIMERGY RX200 S6 Technical Manual Edition August 2010

2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by to Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2010 FujitsuTechnologySolutionsGmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers. The contents of this manual may be revised without prior notice. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. No part of this manual may be reproduced in any form without the prior written permission of Fujitsu. Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries. Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.

3 Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product. Radio interference This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A Aluminum electrolytic capacitors The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke. As a guideline, in a normal office environment (25 C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period. High safety use This product has been designed and manufactured for general uses such as general office use, personal use, domestic use and normal industrial use. It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured. D3031 (RX200 S6) Technical Manual

4 These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended. (This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.) Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law. Harmonic Current Standards This product conforms to harmonic current standard JIS C Only for the Japanese market: About SATA hard disk drives The SATA version of this server supports hard disk drives with SATA / BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of hard disk drive used. Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive: Technical Manual D3031 (RX200 S6)

5 Only for the Japanese market: I Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: CSS (Customer Self Service) Replacing the lithium battery D3031 (RX200 S6) Technical Manual

6 Technical Manual D3031 (RX200 S6)

7 Contents 1 Introduction Notational conventions Important information Notes on safety CE certificate of conformity Environmental protection Features Overview Main memory Module population Modes of operation LV-DIMM support PCI slots Screen resolution Temperature / system monitoring Connectors and indicators System board Connector panel Settings Jumpers Switches Replacing the lithium battery D3031 (RX200 S6) Technical Manual

8 Contents Technical Manual D3031 (RX200 S6)

9 1 Introduction This technical manual describes the system board D3031, which can be equipped with up to two processors. For additional driver information (if available), refer to the Readme files located on the server hard disk and on the supplied DVDs (see Installation DVD of ServerView Suite - ServerView Software Products). You will find further information about the BIOS setup in the "D3031 BIOS Setup Utility for PRIMERGY RX200 S6" manual. I PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2. The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server. PRIMERGY Abbreviations and Glossary can also be found on the ServerView Suite DVD Notational conventions The following notational conventions are used in this manual: Text in italics "Quotation marks" Ê V CAUTION! I indicates commands or menu items. indicate names of chapters and terms that are being emphasized. describes activities that must be performed in the order shown. pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. indicates additional information, notes and tips. D3031 (RX200 S6) Technical Manual 9

10 Introduction 10 Technical Manual D3031 (RX200 S6)

11 2 Important information In this chapter you will find essential information regarding safety when working with your server. V CAUTION! With the system board installed you must open the system to access the system board. How to access the system board of your system is described in the appropriate service supplement (except for the Japanese market). When handling the system board, refer to the specific notes on safety in the operating manual and/or service supplement for the respective server. 2.1 Notes on safety V CAUTION! The actions described in these instructions should only be performed by authorized, qualified personnel. Equipment repairs should only be performed by qualified staff. Any failure to observe the guidelines in this manual, and any unauthorized openings and improper repairs could expose the user to risks (electric shock, fire hazards) and could also damage the equipment. Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability. Transport the device only in the antistatic original packaging or in packaging that protects it from knocks and jolts. Only install expansions that are allowed for the system board. If you install other expansions, you may damage the requirementsand rules governing safety and electromagnetic compatibility or your system. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. D3031 (RX200 S6) Technical Manual 11

12 Notes on safety Important information V CAUTION! Components can become very hot during operation. Ensure you do not touch components when making extensions to the system board. There is a danger of burns! Transmission lines to peripheral devices must be adequately shielded. To the LAN wiring the requirements apply in accordance with the standards EN and EN /2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 Mbit/s Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC are to be considered. Never connect or disconnect data transmission lines during a storm (risk of lightning hazard). Batteries V CAUTION! Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (this information doesn t apply to the Japanese market). It is essential to observe the instructions in the chapter "Replacing the lithium battery". 12 Technical Manual D3031 (RX200 S6)

13 Important information Notes on safety Modules with Electrostatic-Sensitive Devices Modules with electrostatic-sensitive devices are identified by the following sticker: Figure 1: ESD label When you handle components fitted with ESDs, you must always observe the following points: Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs. You must always discharge static build-up (e.g. by touching a grounded object) before working with such components. Any devices or tools that are used must be free of electrostatic charge. Wear a suitable grounding cable that connects you to the external chassis of the system unit. Always hold components with ESDs at the edges or at the points marked green (touch points). Do not touch any connectors or conduction paths on an ESD. Place all the components on a pad which is free of electrostatic charge. I For a detailed description of how to handle ESD components, see the relevant European or international standards (EN , ANSI/ESD S20.20). D3031 (RX200 S6) Technical Manual 13

14 CE certificate of conformity Important information Notes about boards During installation/deinstallation of the board, observe the specific instructions described in the service supplement for the respective server. Shut down the server and disconnect the power plug, before you make modifications on an installed board. To prevent damage to the board, the components and conductors on it, please take great care when you insert or remove boards. Take great care to ensure that extension boards are slotted in straight, without damaging components or conductors on the board, or any other components, for example EMI spring contacts. Be careful with the locking mechanisms (catches, centring pins etc.) when you replace the system board or components on it, for example memory modules or processors. Never use sharp objects (screw drivers) for leverage. Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock. Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards. 2.2 CE certificate of conformity The board complies with the requirements of the EC directives 2004/108/EC regarding "Electromagnetic Compatibility" and 2006/95/EC "Low Voltage Directive". This is indicated by the CE marking (CE = Communauté Européenne). Compliance was tested in a typical PRIMERGY configuration. 14 Technical Manual D3031 (RX200 S6)

15 Important information Environmental protection 2.3 Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account. This saves resources and thus reduces the harm done to the environment. Further information can be found at: (for the EMEA market) (for the Japanese market) Energy-saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work. Packaging information This packaging information doesn t apply to the Japanese market. Do not throw away the packaging. You may need it later for transporting the system. If possible, the equipment should only be transported in its original packaging. Information on handling consumables Please dispose of printer consumables and batteries in accordance with the applicable national regulations. In accordance with EU directives, batteries must not be disposed of with unsorted domestic waste. They can be returned free of charge to the manufacturer, dealer or an authorized agent for recycling or disposal. D3031 (RX200 S6) Technical Manual 15

16 Environmental protection Important information All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants: Cd Cadmium Hg Mercury Pb Lead Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them. Returns, recycling and disposal Please handle returns, recycling and disposal in accordance with local regulations. The device must not be disposed of with domestic waste. This device is labeled in compliance with European directive 2002/96/EC on waste electrical and electronic equipment (WEEE). This directive sets the framework for returning and recycling used equipment and is valid across the EU. When returning your used device, please use the return and collection systems available to you. Further information can be found at Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D Paderborn Tel Fax Technical Manual D3031 (RX200 S6)

17 3 Features I Not all features of the system board might be used in your server system. 3.1 Overview Processors 2 processor sockets LGA or 2 Intel Dual or Quad-Core or LV processors of the Nehalem-EP line with power consumption up to 95 W quick path interconnects (QPI) integrated memory controller or 1 or 2 Intel Quad or Six-Core processors of the Westmere-EP line with power consumption up to 130 W quick path interconnects (QPI) integrated memory controller Main memory 12 slots for main memory; each CPU supports 3 channels with 2 DIMM slots UDIMM (unbuffered DIMM) or RDIMM (registered DIMM) memory modules: capacity UDIMMs: 2 GB capacities RDIMMs: 2 GB, 4 GB, 8 GB or 16 GB LV-DIMM (low voltage DIMM) memory modules, support with Westmere-EP processors only minimum memory configuration: one DIMM with independent channel mode maximum 192 GB (with RDIMMs) or 24 GB (with UDIMMs) of memory ECC multiple bit error detection and single bit error correction memory scrubbing function Single Device Data Correction (SDDC) function (Chipkill ), only with RDIMMs memory mirroring function memory sparing function D3031 (RX200 S6) Technical Manual 17

18 Overview Features Chips on the system board Intel Tylersburg 24D chipset Intel IOH (north bridge) Intel ICH10R (south bridge) Intel dual-port Gigabit Ethernet controller 82575EB onboard irmc S2 Server Management Controller with integrated graphics controller and associated management LAN connector Flash EPROM for: BIOS LAN Server Management (SM) Internal connectors 1x front panel connector 1x video connector (VGA) at the front side 1x SATA connector with 4 ports (hard disk drives) 1x SATA connector (optical disk drive) 1x main power connector 1x power supply monitoring and controlling connector 6x system fan monitoring and controlling connectors 1x connector for USB Flash Module (optional) 1x connector for Trusted Platform Module (optional) 1x connector (2 pin) for external generation of a system reset External connectors Rear side 1x serial connector (COM) 3x USB connectors 1x video connector (VGA) 2x RJ45 LAN connectors 1x RJ45 management LAN connector Front side 3x USB connectors 1x video connector (VGA) PCI slots 2x PCI Express x8 expansion slots 1x PCI Express x4 expansion slot (mechanical x8) 18 Technical Manual D3031 (RX200 S6)

19 Features Overview Power management ACPI (states S0, S1, S5) 3.3 V standby power on the PCI Express slots on/off/sleep/wake by power button on/off by software wake on by RTC, external serial connector, LAN, PCI Express controller and irmc S2 power on by power button, external serial connector, LAN, PCI Express controller and irmc S2 BIOS features Phoenix SecureCore TM Server BIOS, version 6.0 SMBIOS 2.50 (DMI) MultiProcessor Specification 1.4 Server Hardware Design Guide 3.0 WfM 2.0 IPMI V2.0 ACPI 3.0b support USB keyboard/mouse boot possible from: CD-ROM USB drive LAN (PXE and iscsi) console redirection support OEM logo CPU, memory disable memory mirroring and memory sparing support Environmental protection Battery in holder for recycling Form factor 290 x 485 mm CSS (Customer Self Service) This system board supports the CSS functionality. You will find a description of CSS functionality in the operating manual of your server. D3031 (RX200 S6) Technical Manual 19

20 Overview Features USB Flash Module (option) The system board can be equipped with an USB Flash Module (UFM) by the manufacturer or by an add-on kit. The module can be used as optional memory for software (e.g. VMware) or as a software dongle. TPM (option) The system board can be equipped with a TPM (Trusted Platform Module) by the manufacturer or by an add-on kit. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption). The TPM is activated via the BIOS system (for more information, refer to the BIOS manual). V CAUTION! When using the TPM, note the program descriptions provided by the third party manufacturers. You must also create a backup of the TPM content. To do this, follow the third party manufacturer's instructions. Without this backup, if the TPM or the system board is faulty you will not be able to access your data. If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content. 20 Technical Manual D3031 (RX200 S6)

21 Features Main memory 3.2 Main memory The 12 slots (6 for each CPU) for main memory are designed for RDIMM (registered DIMM, capacities: 2, 4, 8 and 16 GB) as well as for UDIMM (unbuffered DIMM, capacity 2 GB) memory modules. The maximum main memory is for installing UDIMM memory modules 24 GB (12x 2 GB), for installing RDIMM memory modules 192 GB (12x 16 GB). Mixing both types of memory modules is not supported and leads to an error message. When using Westmere-EP processors LV-DIMMs (low voltage DIMMs) can be used. ECC with memory scrubbing and with the Single Device Data Correction (SDDC) function (only with RDIMMs) is supported. I You will find the descriptions how to install memory modules in the Options Guide of your server Module population DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU 2 CPU 1 DIMM 2D DIMM 1D DIMM 2E DIMM 1E DIMM 2F DIMM 1F Figure 2: Slots of the main memory Minimum main memory configuration is 1 DIMM with Independent Channel Mode. It is possible to mix memory modules with different clock rates. The lowest clock rate will be applied to the system. D3031 (RX200 S6) Technical Manual 21

22 Main memory Features Single and dual and quad rank memory modules may be mixed. Install the memory module with the highest number of ranks into the slot with the lowest number (e.g. modul typ 4GB 2Rx4 into slot DIMM1A and modul typ 4GB 1Rx4 in slot DIMM2A). In the case of same number of ranks install the memory module with the highest capacity into the slot with lowest number (e.g. 8GB 2Rx4 modules (DIMM-1A) before 4GB 2Rx4 modules (DIMM-2A)). Mix of modules with different capacity is possible bank-wise (2x2) with Mirror or Spare Mode. The assignment of the DIMM slots to the banks and channels is printed on the system board Modes of operation Possible population in the different modes: Independent Channel Mode Mirrored Channel Mode Performance Channel Mode Spare Channel Mode DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU 1 DIMM 1C DIMM 1C DIMM 1C CPU 2 DIMM 2C CPU 2 DIMM 2C CPU 2 DIMM 2C CPU 2 DIMM 1B DIMM 1B DIMM 1B DIMM 2D DIMM 2B DIMM 2D DIMM 2B DIMM 2D DIMM 2B DIMM 2D DIMM 1D DIMM 1A DIMM 1D DIMM 1A DIMM 1D DIMM 1A DIMM 1D DIMM 2E DIMM 2A DIMM 2E DIMM 2A DIMM 2E DIMM 2A DIMM 2E DIMM 1E DIMM 1E DIMM 1E DIMM 1E DIMM 2F CPU 1 DIMM 2F CPU 1 DIMM 2F CPU 1 DIMM 2F DIMM 1F DIMM 1F DIMM 1F DIMM 1F Legend: required optional, same type in bank per CPU not used required, if 2nd CPU is configured optional, any type Figure 3: Possible population in different modes Independent Channel Mode Allows population of all channels in any order. Related to the channels (A-F) DIMM1 must be populated first. Works with DIMMs of different clock rates and applies the lowest clock rate. Works with UDIMMs as well as RDIMMs. 22 Technical Manual D3031 (RX200 S6)

23 Features Main memory Mirrored Channel Mode Requires identical modules on the channels A & B (CPU 1) and on D & E (CPU 2). Half of the capacity is used for the mirroring only the half of the installed main memory is available for the applications. Channel C (CPU 1) respectively channel F (CPU 2) are not available in this mode. RDIMMs are supported. Performance Channel Mode Requires identical modules on all channels of each bank per CPU. RDIMMs are supported. Spare Channel Mode Requires identical modules on all channels of each bank per CPU. One third of the capacity is used as spare range this means the main memory for the applications is reduced to two third. RDIMMs are supported. D3031 (RX200 S6) Technical Manual 23

24 Main memory Features LV-DIMM support LV-DIMMs will be supplied with 1.35 V instead of the 1.5 V of the NV-DIMMs (normal voltage DIMMs). Anyway LV-DIMMs can also be operated with 1.5V so that mixing of LV-DIMMs and NV-DIMMs is possible. In this case all DIMMs will be operated with 1.5 V. Using LV-DIMMs with Nehalem-EP processors is also possible but in this case the DIMMs will always be supplied with 1.5 V. When using two LV-DIMMs 1333 MHz per channel the operating voltage respective speed depends on the BIOS setup memory settings "Auto" / "Energy" / "Performance": "Auto" "Energy" "Performance" speed is set to 1066 MHz; operating voltage is set to 1.35 V speed is set to 800 MHz; operating voltage is set to 1.35 V speed is set to 1333 MHz; operating voltage is set to 1.5 V The speed and operating voltage settings apply to all six sockets of one CPU in common. 24 Technical Manual D3031 (RX200 S6)

25 Features PCI slots 3.3 PCI slots JP2 Front VGA UFM PWR CTRL S1 irmc JP5 SATA1 Slot 2 Battery Slot 3 Slot 1 DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU 1 Figure 4: PCI slots PCI slot Description 1 PCI Express x8 (standard profile, half-length) 2 PCI Express x8 (low profile, half-length) 3 PCI Express x4 - mechanically x8 (low profile, half-length) Expansion cards are integrated on the system board using a riser card. The riser card provides one slot at an angle of 90 to the system board. The following riser cards are available: Riser card with one standard half length PCI Express expansion x8 slot Riser card with one low-profile half length PCI Express expansion x8 slot Riser card with one low-profile half length PCI Express expansion x4 slot (mechanically: x8), reserved for modular RAID option. D3031 (RX200 S6) Technical Manual 25

26 Screen resolution Features 3.4 Screen resolution Depending on the operating system used the screen resolutions in the following table refer to the graphic controller on the system board. The graphic controller is integrated in the irmc S2 (integrated Remote Management Controller). Screen resolution (pixel) Maximum refresh rate (Hz) 640x bit 800x bit 1024x bit 1152x bit 1280x bit 1600x bit Max. number of colours If you are using an external graphic controller, you will find details of supported screen resolutions in the operating manual or technical manual supplied with the graphic controller. 26 Technical Manual D3031 (RX200 S6)

27 Features Temperature / system monitoring 3.5 Temperature / system monitoring Temperature and system monitoring aim to reliably protect the computer hardware against damage caused by overheating. In addition, any unnecessary noise is also prevented by reducing the fan speed, and information is provided about the system status. The temperature and system monitoring are controlled by the irmc S2 controller (integrated Remote Management Controller). The following functions are supported: Temperature monitoring Measurement of the processor temperature, measurement of the ambient temperature by a temperature sensor. Measurement of the memory module temperature by a temperature sensor on the depending memory module. Fan monitoring Fans that are no longer available, blocked or stuck fans are detected. Fan control The fans are controlled according to the temperature. Sensor monitoring The removal of, or a fault in, a temperature sensor is detected. Should this happen all fans monitored by this sensor run at maximum speed, to achieve the greatest possible protection of the hardware. Voltage monitoring When voltage exceeds warning level high or falls below warning level low, an entry in the SEL will be generated. If the corresponding agents are installed, also an alert will be generated. System Event Log (SEL) All monitored events of the system board are signalized via the Global Error LED and recorded in the System Event Log. The events can be retrieved in the BIOS Setup or via the ServerView Operations Manager. D3031 (RX200 S6) Technical Manual 27

28 Connectors and indicators Features 3.6 Connectors and indicators System board PWR Front Panel Reset (top), GND (bottom) PWR CTRL S1 Fan 1/2 Front VGA TPM Slot 2 Slot 1 SATA1 Slot3 SATA ODD Indicate CSS button Fan 3/4 Fan 5/6 CPU 2 Fan 7/8 Fan 9/10 DIMM 2D DIMM 1D DIMM 2E DIMM 1E DIMM 2F DIMM 1F Fan 11/12 UFM JP5 DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU 1 JP2 irmc Figure 5: Internal connectors of the system board D Technical Manual D3031 (RX200 S6)

29 Features Connectors and indicators No. Print Description 1 CN7 Front video connector (VGA) 2 CN10 Connector for USB Flash Module (UFM) 3 CN1 PSU I 2 C connector 4 CN11 SATA1 HDD connector (4 ports) 5 CN13 PSU main connector 6 SATA2 SATA ODD connector 7 JP16 Connector for external generation of a system reset 8 CN2 Front panel connector 9 JP4, P6, J System fan connectors JP7, JP10, JP11, JP12 10 CN30 Connector for TPM D3031 (RX200 S6) Technical Manual 29

30 Connectors and indicators Features PWR Front Panel Reset (top), GND (bottom) Fan 1/2 SATA ODD Indicate CSS button Fan 3/4 S1 JP2 Slot 2 Slot 1 TPM Front VGA UFM JP5 Slot3 PWR CTRL SATA1 Fan 5/6 CPU 2 Fan 7/8 DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU 1 Fan 9/10 DIMM 2D DIMM 1D DIMM 2E DIMM 1E DIMM 2F DIMM 1F Fan 11/12 irmc Figure 6: Indicators on the system board and CSS indicate button 30 Technical Manual D3031 (RX200 S6)

31 Features Connectors and indicators No. Description 1 CSS indicate button LEDs A, B and C are visible from outside on the rear of the server. All the other LEDs are only visible, if the cover of the server has been opened. If the server has been powered off (power-plugs must be disconnected) it is possible to indicate the faulty component by pressing the CSS indicate button. The LEDs have the following meaning: LED Indicator Meaning A - GEL orange on indicates a prefailure (Global Error orange flashing indicates a failure. Reasons for a failure LED) may be: a sensor detects an error sensor defect fan defect CPU rror e Software detected an error B - CSS yellow on indicates a prefailure (Customer Self Service) yellow flashing indicates a failure C - Identification blue on server is identified via the ServerView Operations Manager D - Controller orange on controller failure E - CPU orange on CPU failure F - system fans green on fan okay orange on fan failure G - memory orange on memory module failure H - irmc S2 green flashing irmc S2 okay D3031 (RX200 S6) Technical Manual 31

32 Connectors and indicators Features Connector panel Figure 7: Connector panel No. Description 1 USB connectors 2 Global error indicator (orange), CSS indicator (yellow), ID indicator (blue); (description see preceding section) 3 Management LAN connector (for irmc S2 server management function) 4 Video connector (VGA) 5 Serial connector COM 6 System LAN connector (LAN 2) 7 System LAN connector (LAN 1), also for irmc S2 server management function LAN connectors The system board is equipped with an Intel dual-port Gigabit Ethernet controller (Intel 82575EB). The LAN controller supports transmission rates of 10 Mbit/s, 100 Mbit/s and 1 Gbit/s. The LAN controller also supports WOL functionality by means of Magic Packet. It is also possible to start a system via a LAN without a separate boot hard disk drive. PXE is supported here. The separate management LAN connector is used as a management interface (irmc S2) and is prepared for operation with the Remote Management. Optionally LAN connector 1 can also be used for irmc S2 server management. Each LAN connector has two LEDs which display the speed of the connection and its status: 32 Technical Manual D3031 (RX200 S6)

33 Features Connectors and indicators Figure 8: LAN indicators No Indicator Description 1 LAN link/transfer (management LAN) Steady green signal when a LAN connection exists. Remains dark when no LAN connection exists. Flashes green when LAN transfer takes place. 2 LAN speed (management LAN) 3 LAN link/transfer (system LAN) 4 LAN speed (system LAN) Steady green signal in the event of a LAN transfer rate of 100 Mbit/s. Remains dark in the event of a LAN transfer rate of 10 Mbit/s. Steady green signal when a LAN connection exists. Remains dark when no LAN connection exists. Flashes green when LAN transfer takes place. Flashes yellow in the event of a LAN transfer rate of 1 Gbit/s Steady green signal in the event of a LAN transfer rate of 100 Mbit/s. Remains dark in the event of a LAN transfer rate of 10 Mbit/s. D3031 (RX200 S6) Technical Manual 33

34 Settings Features 3.7 Settings JP2 Front VGA UFM PWR CTRL S1 irmc JP5 SATA1 Slot 2 Slot 3 Battery Slot 1 DIMM 1C DIMM 2C DIMM 1B DIMM 2B DIMM 1A DIMM 2A CPU 1 Figure 9: Jumpers and switches Jumpers I The default setting for all jumpers is position 1-2. Clear CMOS jumper - JP2 Jumper Pos. Description 1-2 Normal, not clear CMOS settings (default setting). 2-3 Clear CMOS settings and restore default values (hardware). 34 Technical Manual D3031 (RX200 S6)

35 Features Settings Proceed as follows to delete the CMOS settings: Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Create a backup of all the data. Shut down the server. Remove all power and peripheral cables. Remove the fan cover and the housing cover. If necessary, remove the expansion card that prevents access to jumper JP2 (Clear CMOS). Remove jumper JP2 from position 1-2 and insert it in position 2-3 for 20 to 30 seconds. Insert jumper JP2 in position 1-2 again. Reinsert the expansion card. Reinstall the housing cover and the fan cover. Connect all the power and peripheral cables again. Switch the server on again. During the POST process press [F2] in order to enter the Setup Utility. Press [F9] to set the system defaults. Press [F10] to save your changes and to exit the Setup Utility. Protect RTC jumper - JP5 Jumper Pos. Description 1-2 Normal operation (default setting) 2-3 Clear ME_RTC REG D3031 (RX200 S6) Technical Manual 35

36 Settings Features Switches I Default setting: switches 1 to 4 are set to Off. Switches Function Status Description S1-1 BIOS recovery On Boot block enabled S1-2 Skip BIOS password query S1-3 BIOS writeprotect S1-4 CMOS clear (software) Off On Off On Off On Off Normal boot Password disabled Password enabled BIOS can only be read BIOS can both be read and written to Clear CMOS settings and restore system defaults Normal CMOS settings 36 Technical Manual D3031 (RX200 S6)

37 4 Replacing the lithium battery In order to save the system information permanently and to power the indicator LEDs D, E, F, G during service (see figure 6), a lithium battery is installed to provide the CMOS-memory with a current. When the charge is too low or the battery is empty, a corresponding error message is provided. The lithium battery must then be replaced. V The lithium battery must be replaced with an identical battery or a battery type recommended by the manufacturer (CR2450). This information doesn t apply to the Japanese market. Do not throw lithium batteries into the trash can. It must be disposed of in accordance with local regulations concerning special waste. Make sure that you insert the battery the right way round. The plus pole must be on the top! Figure 10: Replacing the lithium battery Ê Press the locking spring into direction of the arrow (1), so that the lithium battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). D3031 (RX200 S6) Technical Manual 37

38 Replacing the lithium battery 38 Technical Manual D3031 (RX200 S6)

System Board D3034 for PRIMERGY RX100 S7

System Board D3034 for PRIMERGY RX100 S7 Technical Manual - English System Board D3034 for PRIMERGY RX100 S7 Technical Manual Edition August 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

System Board D2786 for RX200 S5. Technical Manual

System Board D2786 for RX200 S5. Technical Manual System Board D2786 for RX200 S5 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

System Board D2799 for PRIMERGY TX200 S6

System Board D2799 for PRIMERGY TX200 S6 Technical Manual - English System Board D2799 for PRIMERGY TX200 S6 Technical Manual Edition July 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

System Board D2870 for PRIMERGY RX600 S5

System Board D2870 for PRIMERGY RX600 S5 Technical Manual - English System Board D2870 for PRIMERGY RX600 S5 Technical Manual April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

Operating Manual - English. RDX USB 3.0 QuikStor Drive

Operating Manual - English. RDX USB 3.0 QuikStor Drive Operating Manual - English RDX USB 3.0 QuikStor Drive December 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY SX650 Storage Blade. Operating Manual

PRIMERGY SX650 Storage Blade. Operating Manual PRIMERGY SX650 Storage Blade Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

PRIMERGY BX620 S6 Server Blade

PRIMERGY BX620 S6 Server Blade Service Supplement - English PRIMERGY BX620 S6 Server Blade Service Supplement September 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY BX922 S2 Server Blade

PRIMERGY BX922 S2 Server Blade Options Guide - us PRIMERGY BX922 S2 Server Blade Options Guide Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

PRIMERGY BX920 S1 Server-Blade. Service Supplement

PRIMERGY BX920 S1 Server-Blade. Service Supplement PRIMERGY BX920 S1 Server-Blade Service Supplement Edition April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY TX120 S2 Server. Service Supplement

PRIMERGY TX120 S2 Server. Service Supplement PRIMERGY TX120 S2 Server Service Supplement Edition July 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Standard server node for PRIMERGY CX400 M1 multi-node server system

More information

PRIMERGY SX940 S1 Storage Blade

PRIMERGY SX940 S1 Storage Blade Operating manual - English PRIMERGY SX940 S1 Storage Blade Operating manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

Baseboard D3144, CPUMEMR D3145, PCIR D3146 for PRIMERGY RX900 S2

Baseboard D3144, CPUMEMR D3145, PCIR D3146 for PRIMERGY RX900 S2 Technical Manual - English Baseboard D44, MEMR D45, PCIR D46 for PRIMERGY RX9 S Technical Manual Edition May Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

PRIMERGY SX910 S1 Storage Blade

PRIMERGY SX910 S1 Storage Blade Operating Manual - English PRIMERGY SX910 S1 Storage Blade Operating Manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY CX122 S1 Server

PRIMERGY CX122 S1 Server Operating Manual - English PRIMERGY CX122 S1 Server Operating Manual Edition November 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

FUJITSU Server PRIMERGY RX1330 M2

FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual December 2015 Comments Suggestions Corrections The User Documentation Department would like to

More information

PRIMERGY CX400 S1 Server Enclosure

PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual - English PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual Edition December 2012 Comments Suggestions Corrections The User Documentation Department would

More information

FUJITSU Server PRIMERGY RX100 S8

FUJITSU Server PRIMERGY RX100 S8 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX100 S8 Upgrade and Maintenance Manual April 2015 Comments Suggestions Corrections The User Documentation Department would like to know

More information

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC) User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Last Edition August 2017 Comments Suggestions Corrections The User Documentation Department would

More information

FUJITSU Server PRIMERGY RX1330 M3

FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual April 2017 Comments Suggestions Corrections The User Documentation Department would like to know

More information

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191V2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet: http://www.ipcomm.de

More information

PRIMERGY RX300 S2 Server System

PRIMERGY RX300 S2 Server System PRIMERGY PRIMERGY RX300 S2 Server System Monika Spanjaart Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001160 Fax: (++49) 700 / 372 00000

More information

PRIMERGY RX100 S6 Server. Service Supplement

PRIMERGY RX100 S6 Server. Service Supplement PRIMERGY RX100 S6 Server Service Supplement Edition january 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

PRIMERGY BX924 S2 Server Blade

PRIMERGY BX924 S2 Server Blade Operating Manual - English PRIMERGY BX924 S2 Server Blade Operating Manual Edition May 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Fujitsu PRIMERGY TX100 S2 Server

Fujitsu PRIMERGY TX100 S2 Server Datasheet Fujitsu PRIMERGY TX100 S2 Server Enter the world of servers - now with 0-Watt functionality PRIMERGY TX industry standard tower servers: efficient, rock solid, record-breaking performance. PRIMERGY

More information

FUJITSU Server PRIMERGY RX2510 M2

FUJITSU Server PRIMERGY RX2510 M2 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX2510 M2 Upgrade and Maintenance Manual June 2017 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY RX300 S5. Service Supplement

PRIMERGY RX300 S5. Service Supplement PRIMERGY RX300 S5 Service Supplement Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server Expandable all-round server for

More information

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191C2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de

More information

FUJITSU Server PRIMERGY RX1330 M1

FUJITSU Server PRIMERGY RX1330 M1 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M1 Upgrade and Maintenance Manual August 2014 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY RX600 S5 Server

PRIMERGY RX600 S5 Server Service Supplement - English PRIMERGY RX600 S5 Server Service Supplement June 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

FUJITSU Server PRIMERGY TX1320 M3

FUJITSU Server PRIMERGY TX1320 M3 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY TX1320 M3 Upgrade and Maintenance Manual April 2017 Comments Suggestions Corrections The User Documentation Department would like to know

More information

Data Sheet Fujitsu PRIMERGY TX1330 M2 Server

Data Sheet Fujitsu PRIMERGY TX1330 M2 Server Data Sheet Fujitsu PRIMERGY TX1330 M2 Server Expandable all-round server for SMEs PRIMERGY TX1330 M2 The FUJITSU Server PRIMERGY TX1330 M2 is the ideal robust, expandable, and cost-efficient server for

More information

PRIMERGY RX300 S5. Operating manual

PRIMERGY RX300 S5. Operating manual PRIMERGY RX300 S5 Operating manual Edition september 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

D2863 BIOS Setup Utility for PRIMERGY RX100 S6. Reference Manual

D2863 BIOS Setup Utility for PRIMERGY RX100 S6. Reference Manual D2863 BIOS Setup Utility for PRIMERGY RX100 S6 Reference Manual Edition January 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

PRIMERGY BX620 S3 2-way Server Blade

PRIMERGY BX620 S3 2-way Server Blade PRIMERGY PRIMERGY BX620 S3 2-way Server Blade Options Guide Walter Dick Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 52 51)14888-12 Fax:

More information

PRIMERGY TX120 S2 Server. Operating manual

PRIMERGY TX120 S2 Server. Operating manual PRIMERGY TX120 S2 Server Operating manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY BX920 S2 Server Blade

PRIMERGY BX920 S2 Server Blade Operating Manual - English PRIMERGY BX920 S2 Server Blade Operating Manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server Expandable all-round server for SMEs PRIMERGY TX1330 M1 The PRIMERGY TX1330 M1 is the

More information

Fujitsu PRIMERGY BX920 S1 Dual-Socket Server

Fujitsu PRIMERGY BX920 S1 Dual-Socket Server Datasheet Fujitsu PRIMERGY BX920 S1 Dual-Socket Server Blade All-around server blade packing lots of computing power in small form factor. The PRIMERGY BX Blade Servers are the ideal choice for data center

More information

System Board D2619 for RX/TX300 S5. Technical Manual

System Board D2619 for RX/TX300 S5. Technical Manual System Board D2619 for RX/TX300 S5 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY TX300 S6 Server

PRIMERGY TX300 S6 Server Service Supplement - English PRIMERGY TX300 S6 Server Service Supplement Edition March 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Industrial PC IPC191V3 (Linux OS) IPC191V3WIN (Windows OS) General Operating, Maintenance and Installation Manual

Industrial PC IPC191V3 (Linux OS) IPC191V3WIN (Windows OS) General Operating, Maintenance and Installation Manual Industrial PC IPC191V3 ( OS) IPC191V3WIN (Windows OS) General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 92076-0 Fax: +49 9131

More information

PRIMERGY RX300 S4. Options Guide

PRIMERGY RX300 S4. Options Guide PRIMERGY RX300 S4 Options Guide Edition June 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

PRIMERGY CX400 S2 Server Enclosure

PRIMERGY CX400 S2 Server Enclosure Operating Manual - English PRIMERGY CX400 S2 Server Enclosure Operating Manual Edition December 2013 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of

More information

Chapter 1 Names and Functions This chapter explains the names and functions of the parts.

Chapter 1 Names and Functions This chapter explains the names and functions of the parts. PRIMERGY SX650 Storage Blade Hardware Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Make sure to read before using

More information

PRIMERGY RX200 S5. Operating Manual

PRIMERGY RX200 S5. Operating Manual PRIMERGY RX200 S5 Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

D3049 BIOS Setup Utility for PRIMERGY TX140 S1 / TX120 S3

D3049 BIOS Setup Utility for PRIMERGY TX140 S1 / TX120 S3 Reference Manual - English D3049 BIOS Setup Utility for PRIMERGY TX140 S1 / TX120 S3 Reference Manual Edition May 2011 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY TX100 S3 Server

PRIMERGY TX100 S3 Server Operating Manual - English PRIMERGY TX100 S3 Server Operating Manual Edition November 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

4170 POS System Installation Guide

4170 POS System Installation Guide 4170 POS System 4170 Installation Guide Thank you for selecting UTC RETAIL s innovative Model 4170 Point of Sale solution! This Installation Guide will help you efficiently install the 4170 POS. The document

More information

PRIMERGY BX630 S2 Scalable Server Blade. Operating Manual

PRIMERGY BX630 S2 Scalable Server Blade. Operating Manual PRIMERGY BX630 S2 Scalable Server Blade Operating Manual Edition October 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

PRIMERGY BX920 S3 Server Blade

PRIMERGY BX920 S3 Server Blade Upgrade and Maintenance Manual - English PRIMERGY BX920 S3 Server Blade Upgrade and Maintenance Manual Edition February 2014 Comments Suggestions Corrections The User Documentation Department would like

More information

Data Sheet ESPRIMO P2550. Your immediately available Office PC ESPRIMO P2550

Data Sheet ESPRIMO P2550. Your immediately available Office PC ESPRIMO P2550 Data Sheet Your immediately available Office PC Issue: October 2009 The is designed for price-conscious customers and is equipped with state-of-the-art standard Intel technology. These systems meet every

More information

Read Me First. FUJITSU Storage ETERNUS CS800 S6. Table of Contents P3AM EN. ETERNUS CS800 S6 Manuals Package Contents...

Read Me First. FUJITSU Storage ETERNUS CS800 S6. Table of Contents P3AM EN. ETERNUS CS800 S6 Manuals Package Contents... FUJITSU Storage ETERNUS CS800 S6 Read Me First Fujitsu would like to thank you for purchasing our FUJITSU Storage ETERNUS CS800 S6 (hereinafter referred to as "ETERNUS CS800 S6"). Read this document and

More information

Modular RAID Controllers

Modular RAID Controllers User Guide - English Modular RAID Controllers "RAID 0/1 SAS based on LSI MegaRAID" "RAID 5/6 SAS based on LSI MegaRAID" "RAID Ctrl SAS 6G 0/1 (D2607)" "RAID Ctrl SAS 6G 5/6 512MB (D2616)" "PY SAS RAID

More information

Server PRIMERGY RX1330 M3

Server PRIMERGY RX1330 M3 Reference Manual - English D3375 BIOS Setup Utility for FUJITSU Server PRIMERGY RX1330 M3 Reference Manual Edition March 2017 Comments Suggestions Corrections The User Documentation Department would like

More information

CAF-1000 Series Communication Appliance. User s Manual Revision: 1.0

CAF-1000 Series Communication Appliance. User s Manual Revision: 1.0 CAF-1000 Series Communication Appliance User s Manual Revision: 1.0 CE This certificate of conformity of COS-0906 series with actual required safety standards in accordance with 89/366 ECC-EMC Directive

More information

NEC Express5800/R120e-1M System Configuration Guide

NEC Express5800/R120e-1M System Configuration Guide NEC Express5800/R120e-1M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ NanoServ Thin System/Ultra-Thin System Setup Guide 1.0 What s included with the NanoServ The following items are included with the NanoServ : 1. NanoServ 2. AC Power Adaptor 3. CD-ROM with User s Manual

More information

M1034W Engineering Workstation

M1034W Engineering Workstation M1034W Engineering Workstation Container Contents Included in container The list below shows components included in an M1034W Engineering Workstation container. M1034W Engineering Workstation Chassis mounting

More information

PRIMERGY CX272 S1 Server Node

PRIMERGY CX272 S1 Server Node Upgrade and Maintenance Manual - English PRIMERGY CX272 S1 Server Node Upgrade and Maintenance Manual February 2014 Comments Suggestions Corrections The User Documentation Department would like to know

More information

Data Sheet Fujitsu PRIMERGY TX1310 M1 Server

Data Sheet Fujitsu PRIMERGY TX1310 M1 Server Data Sheet Fujitsu PRIMERGY TX1310 M1 Server Data Sheet Fujitsu PRIMERGY TX1310 M1 Server The ideal first server PRIMERGY TX1310 M1 The Fujitsu PRIMERGY TX1310 M1 is the ideal first server for small and

More information

Card Enrollment Station. User Manual UD05870B

Card Enrollment Station. User Manual UD05870B Card Enrollment Station User Manual UD05870B User Manual 2017 Hangzhou Hikvision Digital Technology Co., Ltd. This manual is applied for D8E series card enrollment station. It includes instructions on

More information

PRIMERGY TX120 S3 Server

PRIMERGY TX120 S3 Server Operating Manual - English PRIMERGY TX120 S3 Server Operating Manual Edition May 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

Manual Version: V1.00. Video Decoder Quick Guide

Manual Version: V1.00. Video Decoder Quick Guide Manual Version: V1.00 Video Decoder Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

Data Sheet Fujitsu PRIMERGY RX4770 M2 Server

Data Sheet Fujitsu PRIMERGY RX4770 M2 Server Data Sheet Fujitsu PRIMERGY RX4770 M2 Server Data Sheet Fujitsu PRIMERGY RX4770 M2 Server Platform of choice for business critical backend services with superior levels of performance and reliability enhanced

More information

P321-E122-04EN PRIMEPOWER PRIMEPOWER200 PRIMEPOWER400 PRIMEPOWER600

P321-E122-04EN PRIMEPOWER PRIMEPOWER200 PRIMEPOWER400 PRIMEPOWER600 P321-E122-04EN PRIMEPOWER PRIMEPOWER200 PRIMEPOWER400 PRIMEPOWER600 Preface This manual explains the features, functions, installation and additions to the PRIMEPOWER200, PRIMEPOWER400 and PRIMEPOWER600

More information

D3143 BIOS Setup Utility for PRIMERGY BX924 S4

D3143 BIOS Setup Utility for PRIMERGY BX924 S4 Reference Manual - English D3143 BIOS Setup Utility for PRIMERGY BX924 S4 Reference Manual Edition December 2013 Comments Suggestions Corrections The User Documentation Department would like to know your

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

D2799 BIOS Setup Utility for PRIMERGY TX200 S6

D2799 BIOS Setup Utility for PRIMERGY TX200 S6 Reference Manual - Englisch D2799 BIOS Setup Utility for PRIMERGY TX200 S6 Reference Manual Edition July 2010 Comments Suggestions Corrections The User Documentation Department would like to know your

More information

Data Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy

Data Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy Data Sheet Fujitsu Server Compact and Easy Data Sheet Fujitsu Server Compact and Easy Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing The Fujitsu Server helps to meet the immense challenges

More information

Server PRIMERGY TX1320 M1

Server PRIMERGY TX1320 M1 Reference Manual - English D3239 BIOS Setup Utility for FUJITSU Server PRIMERGY TX1320 M1 Reference Manual Edition July 2015 Comments Suggestions Corrections The User Documentation Department would like

More information

Intel NUC Kit NUC6CAYS User Guide

Intel NUC Kit NUC6CAYS User Guide Intel NUC Kit NUC6CAYS User Guide Regulatory Model NUC6CAY 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices and regulatory

More information

PRIMERGY TX120 Server. Operating Manual

PRIMERGY TX120 Server. Operating Manual PRIMERGY TX120 Server Operating Manual Edition July 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

Data Sheet Fujitsu PRIMERGY TX100 S3 Server

Data Sheet Fujitsu PRIMERGY TX100 S3 Server Data Sheet Fujitsu PRIMERGY TX100 S3 Server Enter the world of PRIMERGY TX servers PRIMERGY TX tower servers are ideal for use in SMEs or branch offices. They increase operational efficiency by providing

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

D3373 BIOS Setup Utility for FUJITSU Server PRIMERGY TX1320 M2

D3373 BIOS Setup Utility for FUJITSU Server PRIMERGY TX1320 M2 Reference Manual - English D3373 BIOS Setup Utility for FUJITSU Server PRIMERGY TX1320 M2 Reference Manual Edition January 2017 Comments Suggestions Corrections The User Documentation Department would

More information

M1032W Engineering Workstation. The list below shows components included in an M1032W Engineering Workstation container.

M1032W Engineering Workstation. The list below shows components included in an M1032W Engineering Workstation container. M1032W Engineering Workstation Container Contents Included in container The list below shows components included in an M1032W Engineering Workstation container. M1032W Engineering Workstation Chassis mounting

More information

DIVAR IP 2000 DIP N, DIP HD, DIP HD. en Quick Installation Guide

DIVAR IP 2000 DIP N, DIP HD, DIP HD. en Quick Installation Guide DIVAR IP 2000 DIP-2040-00N, DIP-2042-2HD, DIP-2042-4HD en Quick Installation Guide DIVAR IP 2000 Table of Contents en 3 Table of contents 1 Safety precautions 4 1.1 General safety precautions 4 1.2 Electrical

More information

PRIMERGY MX130 S2 Server

PRIMERGY MX130 S2 Server Upgrade and Maintenance Manual - English PRIMERGY MX130 S2 Server Upgrade and Maintenance Manual Edition November 2011 Comments Suggestions Corrections The User Documentation Department would like to know

More information

Fujitsu PRIMERGY BX960 S1 Quad socket server

Fujitsu PRIMERGY BX960 S1 Quad socket server Datasheet Fujitsu PRIMERGY BX960 S1 Quad socket server blade Datasheet for Red Hat certification Dynamics paired with high scaling The PRIMERGY BX Blade Servers are the ideal choice for data center solutions

More information

Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade

Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade Universal dual socket server blade with high computing and I/O performance in a small form factor The PRIMERGY BX Blade Servers are the ideal

More information

MITAC Desktop Board PD10TI Product Guide

MITAC Desktop Board PD10TI Product Guide MITAC Desktop Board PD10TI Product Guide Desktop Board Features This chapter briefly describes the main features of MITAC Desktop Board PD10TI. Table 1 summarizes the features of the Desktop Board. TABLE

More information

RS500-E6/PS4. Configuration Guide

RS500-E6/PS4. Configuration Guide RS500-E6/PS4 Configuration Guide E4332 First Edition V1 February 2009 Copyright 2009 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in

More information

MIL-STD Rugged Computer User's Manual. Version 1.0 Revision Date: July. 05, 2017 THOR200. MIL-STD Rugged Computer

MIL-STD Rugged Computer User's Manual. Version 1.0 Revision Date: July. 05, 2017 THOR200. MIL-STD Rugged Computer THOR200 MIL-STD Rugged Computer Safety information Electrical safety To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system. When adding

More information

PRIMERGY RX100 S7 Server

PRIMERGY RX100 S7 Server Operating Manual - English PRIMERGY RX100 S7 Server Operating Manual Edition June 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

MITAC Desktop Board PD12TI Product Guide

MITAC Desktop Board PD12TI Product Guide MITAC Desktop Board PD12TI Product Guide Desktop Board Features This chapter briefly describes the main features of MITAC Desktop Board PD12TI. Table 1 summarizes the features of the Desktop Board. Table

More information

PRIMERGY BX900/BX400 Blade Server Systems

PRIMERGY BX900/BX400 Blade Server Systems Operating Manual - English PRIMERGY BX900/BX400 Blade Server Systems Connection Blade SAS Switch 6 Gb 18/6 September 2013 Comments Suggestions Corrections The User Documentation Department would like to

More information

PRIMERGY BX924 S2. System configurator and order-information guide September PRIMERGY Server. Contents

PRIMERGY BX924 S2. System configurator and order-information guide September PRIMERGY Server. Contents PRIMERGY BX924 S2 System configurator and order-information guide September 2012 Contents Instructions Configuration diagram Configurator # X BX924 S2 Dual Socket 20 # XI Processor 21 # XII Storage # XIII

More information

Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade

Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade Datasheet for Red Hat certification High-end server blade with

More information

NEC Express5800/R120d-2M Configuration Guide

NEC Express5800/R120d-2M Configuration Guide NEC Express5800/R120d-2M Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper

More information

D3342 BIOS Setup Utility for FUJITSU Server PRIMERGY RX4770 M1

D3342 BIOS Setup Utility for FUJITSU Server PRIMERGY RX4770 M1 Reference Manual - English D3342 BIOS Setup Utility for FUJITSU Server PRIMERGY RX4770 M1 Reference Manual Edition July 2015 / BIOS 1.31 and higher Comments Suggestions Corrections The User Documentation

More information

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Scale-Out Smart for HPC and Cloud Computing with enhanced

More information

PRIMERGY Econel 200 S2 Server. Operating manual

PRIMERGY Econel 200 S2 Server. Operating manual PRIMERGY Econel 200 S2 Server Operating manual Edition March 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY RX600 S4 Server. Service Supplement

PRIMERGY RX600 S4 Server. Service Supplement PRIMERGY RX600 S4 Server Service Supplement Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL User Guide 1 Before You Begin CAUTIONS The procedures in this guide assume familiarity with the general terminology associated with personal

More information

PRIMERGY RX200 S4 Server. Operating manual

PRIMERGY RX200 S4 Server. Operating manual PRIMERGY RX200 S4 Server Operating manual Edition January 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A Installation Guide Standalone/Spare V6 SDI QBox QBox-V6 Standalone/Spare V6 SDI QBox Part No. A9009-0004 EN www.autocue.com Copyright 2017 All rights reserved. Original Instructions: English All rights

More information

Data Sheet Fujitsu PRIMERGY BX924 S3 Dual Socket Server Blade

Data Sheet Fujitsu PRIMERGY BX924 S3 Dual Socket Server Blade Data Sheet Fujitsu PRIMERGY BX924 S3 Dual Socket Server Blade High-end server blade with maximum scalability for demanding applications Fujitsu PRIMERGY BX Blade Servers provide a faster, simpler and lower-cost

More information