System Board D2671 for RX200 S4. Technical Manual

Size: px
Start display at page:

Download "System Board D2671 for RX200 S4. Technical Manual"

Transcription

1 System Board D2671 for RX200 S4 Technical Manual Edition December 2007

2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by to Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2007 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.

3 Contents 1 Introduction Important notes Notes on safety CE Certificate of Conformity Environmental protection Features Overview Main memory PCI slots Screen resolution Temperature / system monitoring Ports and indicators External ports and indicators Internal diagnostic LEDs indicators Settings with jumpers Replacing the lithium battery Abbreviations D2671 (RX200 S4) Technical Manual

4

5 1 Introduction This technical manual describes the system board D2671, which is equipped with one or two Intel processors. Further information you will find in the BIOS description. For additional driver information, refer to the Readme files located on the server hard disk and on the supplied CDs or DVDs. Notational conventions The meanings of the symbols and fonts used in this manual are as follows: italics fixed font semi-bold fixed font [Key symbol] "Quotation marks" Ê V CAUTION! I indicates commands, menu options or software programs. indicate system output on the monitor. indicates values to be entered through the keyboard. indicates keys according to their representation on the keyboard. If capital letters are to be entered explicitly, then the Shift key is shown, e.g. [SHIFT] - [A] for A. If two keys need to be pressed at the same time, then this is shown by placing a hyphen between the two key symbols. Indicates names of chapters and terms that are being emphasized. Describes an operation that must be performed. Pay particular attention to texts marked with this symbol. Failure to observe these warnings may endanger your life, destroy the system or lead to the loss of data. Indicates additional information, notes and tips Table 1: Notational conventions D2671 (RX200 S4) Technical Manual 5

6

7 2 Important notes In this chapter you will find essential information regarding safety when working with the system boardserver. V CAUTION! With the system board installed you must open the system to access the system board. How to access the system is described in the service supplement manual accompanying your system. When installing the system board, refer to the specific installation information in the operating and/or service supplement manual for the respective server. 2.1 Notes on safety V CAUTION! The actions described in these instructions should only be performed by authorized, qualified personnel. Equipment repairs should only be performed by qualified staff. Any failure to observe the guidelines in this manual, and any unauthorized openings and improper repairs could expose the user to risks (electric shock, fire hazards) and could also damage the equipment. Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability. Transport the device only in the antistatic original packaging or in packaging that protects it from knocks and jolts. Only install expansions that are allowed for the system board. If you install other expansions, you may damage the requirements and rules governing safety and electromagnetic compatibility or your system. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. D2671 (RX200 S4) Technical Manual 7

8 Notes on safety Important notes V Components can become very hot during operation. Ensure you do not touch components when making extensions to the system board. There is a danger of burns! Transmisson lines to peripheral devices must be adequately shielded. To the LAN wiring the requirements apply in accordance with the standards EN and EN /2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 MBps Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC are to be considered. Never connect or disconnect data transmission lines during a storm (risk of lightning hazard). Batteries V CAUTION! Incorrect replacement of lithium battery may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer. It is essential to observe the instructions in the chapter Replacing the lithium battery. 8 Technical Manual D2671 (RX200 S4)

9 Important notes Notes on safety Modules with electrostatic-sensitive components Boards with electrostatic sensitive devices (ESD) are marked with the following label: Figure 1: ESD label You must follow the instructions below when handling modules containing electrostatic-sensitive components You must always discharge yourself of static charges (e.g. by touching a grounded object) before touching the components. The equipment and tools you use must be free of static charges. Remove the power plug from the power socket before inserting or removing boards containing ESDs. Always hold boards with ESDs by theit edges. Do not touch any exposed pins or conductors on a component. Use a grounding cable designed for this purpose to connect yourself to the system unit as you install/deinstall the board. Place all components on a static-free surface. I You will find a detailed description for handling ESD components in the relevant European or international standards (EN , ANSI/ESD S20.20). D2671 (RX200 S4) Technical Manual 9

10 CE Certificate of Conformity Important notes Notes about boards During installation/deinstallation of the system board, observe the specific instructions described in the service manual for the server. Remove the plug from the mains outlet so that system and system board are totally disconnected from the mains voltage. To prevent damage to the system board, the components and conductors on it, please take great care when you insert or remove boards. Take great care to ensure that extension boards are slotted in straight, without damaging components or conductors on the system board, or any other components, for example EMI spring contacts. Be careful with the locking mechanisms (catches, centring pins etc.) when you replace the system board or components on it, for example memory modules or processors. Never use sharp objects (screwdrivers) for leverage. 2.2 CE Certificate of Conformity The shipped version of this board complies with the requirements of the EEC directive 89/336/EEC "Electromagnetic compatibility". Compliance was tested in a typical PRIMERGY configuration. 10 Technical Manual D2671 (RX200 S4)

11 Important notes Environmental protection 2.3 Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu Siemens Computers standard for environmentally friendly product design and development. This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account. This saves resources and thus reduces the harm done to the environment. Energy-saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work. Packaging information Do not throw away the packaging. You may need it later for transporting the system. If possible, the equipment should only be transported in its original packaging. Information on handling consumables Please dispose of batteries in accordance with local regulations. In accordance with EU directives, batteries must not be disposed of with unsorted domestic waste. They can be returned free of charge to the manufacturer, dealer or an authorized agent for recycling or disposal. All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants: Cd Cadmium Hg Mercury Pb Lead D2671 (RX200 S4) Technical Manual 11

12 Environmental protection Important notes To Germany applies: Private customers can return spent batteries free of charge at the point of sale or in its immediate proximity. The commercial end-user is legally obliged to return defective or spent batteries to the distributor or designated return and collection systems available to you. Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them. Returns, recycling and disposal The device must not be disposed of with domestic waste. This device is labeled in compliance with European directive 2002/96/EG on waste electrical and electronic equipment (WEEE). This directive sets the framework for returning and recycling used equipment and is valid across the EU. When returning your used device, please use the return and collection systems available to you. Further information can be found at Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu Siemens Computers branch or from our recycling center in Paderborn: Fujitsu Siemens Computers Recycling Center D Paderborn Tel Fax Technical Manual D2671 (RX200 S4)

13 3 Features 3.1 Overview Processors 1 or 2 x Intel Dual or Quad-Core Xeon processors 2 processor sockets LGA771 for Intel Dual-Core Xeon Woodcrest / Woodcrest LV processors with 1066/1333 MHz front side bus (266/333 MHz quadruple transmission rate), second-level cache 4 MB, max. clock frequency 3 GHz, max. power draw 80 W Intel Dual-Core Xeon Wolfdale DP / Wolfdale DP Performance processors with 1066/1333 MHz front side bus (266/1333 MHz quadruple transmission rate), second-level cache 6 MB, max. clock frequency 3 GHz and more, power draw approx. 65/80 W Intel Quad-Core Xeon Clovertown / Clovertown LV / Clovertown Performance processors with 1066/1333 MHz front side bus (266/1333 MHz quadruple transmission rate), second-level cache 8 MB, max. clock frequency 3 GHz and more, max. power draw 120 W Intel Quad-Core Xeon Harpertown / Harpertown Performance processors with 1066/1333 MHz front side bus (266/1333 MHz quadruple transmission rate), second-level cache 12 MB, max. clock frequency 3 GHz and more, max. power draw 120 W Main memory 12 slots for main memory FBD-533 and FBD-667 (FBD - Fully Buffered DIMMs) memory modules 2 branches, each with 2 channels for three modules for 512 MB, 1 Gbyte, 2 Gbyte and 4 Gbyte of memory maximum 48 Gbyte of memory supports 2 way and 4 way interleaved memory subsystems (2 or 4 identical memory modules have to installed at the same time) ECC multiple bit error detection and single bit error correction memory scrubbing function D2671 (RX200 S4) Technical Manual 13

14 Overview Features Single Device Data Correction (SDDC) function (Chipkill ) memory mirroring function memory sparing function Chips on the system board Intel 5000P chipset (Blackford) Intel 5000P Memory Controller Hub (MCH) Chipset (north bridge) Intel 6311 ESB2-T I/O Controller Hub (south bridge) 2 LAN Controller Broadcom NetXtreme BCM5708C (10/100/1000BASE-T TOE and Ethernet Controller with PCI Express) ISCSI 1.0/iSER Host Bus Adapter (HBA) RDMA Network Interface Controller (RNIC) TOE Chimney-enabled network accelerator Supports WOL functionality with Magic PacketTM Supports PXE functionality (Remote Boot) Onboard irmc S2 Server Management Controller with integrated graphics controller and associated 10/100 service LAN port Flash EPROM for: IME firmware BIOS LAN Server Management (SM) Internal connectors 1 SATA connector (DVD-ROM) 2 SATA connectors (only for 3.5" hard disk) 1 USB connector (USB 2.0) I 2 C connector power connector (12V, 5V, 3.3V, -12V, 5V standby) 14 Technical Manual D2671 (RX200 S4)

15 Features Overview power supply monitoring and controlling fan backplane monitoring and controlling I 2 C connector to the SAS/SATA HDD backplane HDD activity connector control panel battery holder External connectors 1 serial port (COM1) for system and BMC (shared) 2 PS/2 interfaces for keyboard and mouse 4 USB 2.0 ports with 480 Mbits/s (2 x front, 2 x rear) 1 VGA port 2 RJ45 LAN ports 1 service LAN port PCI slots There are three PCI expansion slots on the system board: Two PCI Express x8 expansion slots One PCI Express x4 expansion slot (low-profile, half-length) The Riser card contained in the PCI Riser Kit optionally provides three expansion slots arranged at an angle of 90 instead of the three expansion slots on the system board. One standard half length PCI Express expansion x8 slot One low-profile half length PCI Express expansion x8 slot One low-profile half length PCI Express expansion x4 slot (mechanically: x8), intended for an optional SAS RAID card only. D2671 (RX200 S4) Technical Manual 15

16 Overview Features BIOS features Phoenix BIOS V 4.0 Release 6.0 SMBIOS 2.31 (DMI) MultiProcessor Specification 1.4 Server Hardware Design Guide 3.0 WfM 2.0 IPMI V2.0 ACPI 1.0b support LSI SCSI BIOS with IME (Integrated Mirroring Enhanced) USB keyboard/mouse boot possible from: CD-ROM USB drive LAN (PXE and iscsi) console redirection support OEM logo CPU, memory disable memory mirroring and memory sparing support Environmental protection Battery in holder Form factor 285 x 455 mm 16 Technical Manual D2671 (RX200 S4)

17 Features Main memory 3.2 Main memory The system board supports up to 48 Gbyte main memory. 12 slots (2 branches each with 2 channels with 3 slots each) are available for the main memory. ECC with memory scrubbing and with the Single Device Data Correction (SDDC) function is supported. The 12 slots are divided into 4 channels with 3 slots each: Channel 1: FBD 1A, FBD 2A and FBD 3A Channel 2: FBD 1B, FBD 2B and FBD 3B Channel 3: FBD 1C, FBD 2C and FBD 3C Channel 4: FBD 1D, FBD 2D and FBD 3D Figure 2: Structure of the main memory in channels and slots 1 DIMM slots channel 1 FBD 1A-3A 2 DIMM slots channel 2 FBD 1B-3B 3 DIMM slots channel 3 FBD 1C-3C 4 DIMM slots channel 4 FBD 1D-3D D2671 (RX200 S4) Technical Manual 17

18 Main memory Features Module population The memory modules have to be registered Fully Buffered DIMMs (ECC DDR2 533/667). Memory modules with 512 MB, 1 Gbyte, 2 Gbyte or 4 Gbyte of memory can be used. The memory slots have to be populated in pairs. The module capacity between pairs can differ: pair 1A/1B can be populated with two 512 Mbyte modules and pair 2A/2B with two 1 Gbyte modules. In the case of a mixed configuration, the memory module pairs with the lower capacity should be installed first. Install identical modules (of the same type, manufacturer, speed, timing, and organization) per the instructions below: When operating in non-mirror mode: Always use two DIMMs per configuration for a memory upgrade. Install the first pair in the FBD 1A and FBD 1B slots. Observe the following channel pair sequence during installation: FDB 1C FDB 1D FBD 2A FDB 2B FBD 2C FDB 2D FBD 3A FDB 3B FBD 3C FDB 3D When operating in single DIMM mode, the module should be installed in the FBD 1A slot. 18 Technical Manual D2671 (RX200 S4)

19 Features PCI slots 3.3 PCI slots Figure 3: Representation of the PCI slots PCI slot Description 1 PCI Express x8 (low profile, half-length) 2 PCI Express x8 (standard profile, half-length) 3 PCI Express x4 - mechanically x8 (low profile, half-length) PCI additional cards are integrated on the system board using a Riser card. The Riser card provides three expansion slots at an angle of 90 to the system board (two slots for PCIe controllers and one slot for a RAID card). D2671 (RX200 S4) Technical Manual 19

20 Screen resolution Features 3.4 Screen resolution Depending on the operating system used the screen resolutions in the following table refer to the screen controller on the system board. If you are using an external screen controller, you will find details of supported screen resolutions in the operating manual or technical manual supplied with the controller. Screen resolution Refresh rate (Hz) Max. number of colours 640x bit 800x bit 1024x bit 1152x bit 1280x bit 1600x bit 3.5 Temperature / system monitoring Temperature and system monitoring aim to reliably protect the computer hardware against damage caused by overheating. In addition, any unnecessary noise is also prevented by reducing the fan speed, and information is provided about the system status. The temperature and system monitoring are controlled by the irmc controller (integrated Remote Management Controller). The following functions are supported: Temperature monitoring Measurement of the processor temperature, measurement of the ambient temperature by a temperature sensor on the LED board. Fan monitoring Fans that are no longer available, blocked or sticky fans are detected. Fan control The fans are regulated according to temperature. 20 Technical Manual D2671 (RX200 S4)

21 Features Temperature / system monitoring Sensor monitoring The removal of, or a fault in, a temperature sensor is detected. Should this happen all fans monitored by this sensor run at maximum speed, to achieve the greatest possible protection of the hardware. Voltage monitoring When voltage exceeds warning level high or falls below warning level low, an entry in the SEL will be generated. If the corresponding agents are installed, also an alert will be generated. System Event Log (SEL) All monitored events of the system board are signalised via the Global Error LED and recorded in the System Event Log. They could be retrieved in the BIOS Setup or via ServerView. PRIMERGY Diagnostic LEDs LEDs on the system board enable to identify defective modules and components as well as gaining information on the PDA. D2671 (RX200 S4) Technical Manual 21

22 Ports and indicators Features 3.6 Ports and indicators Figure 4: Schematic overview of the system board D Technical Manual D2671 (RX200 S4)

23 Features Ports and indicators Pos. Code Component description 1 RJ3 Service LAN port (for irmc server management function) 2 RJ2 (LAN2) GbE LAN port 2 3 CN9 Video port (blue) 4 CN3 Serial port COM 5 USB2, USB1 Rear USB ports (USB 2.0) 6 LED13 Top: Global error/css LED indicator(bicolor LED: amber/yellow) Bottom: ID LED indicator (blue LED) 7 RJ1 (LAN1) GbE LAN port 1 (can be shared by irmc for server management function) 8 SKT2 PS/2 mouse port (green) 9 SKT1 PS/2 keyboard port (violet) 10 U11 Broadcom BCM5708C NetXtreme Gigabit Ethernet Controller 11 FBD 1D-3D Channel 4 DIMM slots 12 FBD 1C-3C Channel 3 DIMM slots 13 CN7 PCI Express x4 expansion slot (low-profile, half-length) - mechanically: x8. Intended for an optional SAS RAID card only. 14 U12 Intel 5000P chipset (north bridge) 15 FBD 1B-3B Channel 2 DIMM slots 16 FBD 1A-3A Channel 1 DIMM slots 17 CN1 Front USB ports system board connector 18 CPU1 Intel LGA771 processor 1 socket 19 Air flow regulators 20 CPU2 Intel LGA771 processor 2 socket 21 CN17 System board power connector 22 CN27 Fan board connector Connects to the CN2 connector of the fan board. 23 CN19 PSU I2C connector D2671 (RX200 S4) Technical Manual 23

24 Ports and indicators Features Pos. Code Component description 24 CN24 HDD backplane board I2C bus connector Connects to the CN14 connector of the backplane board. 25 CN18 SATA ODD cable connector 26 CN26 SAS HDD activity LED cable connector Reserved for designated RAID card connection. 27 CN28 SATA cable connector Connects to the CN4 connector of the backplane board. 28 U60 Intel ESB2-T (Enterprise South Bridge 2-T) chipset 29 S1 System configuration switch 30 CN29 Internal USB cable connector (USB 2.0) 31 BZ1 Internal buzzer 32 U59 SMSC DME1737 Super I/O chipset 33 U77 Firmware hub (FWH) 34 BT1 System RTC battery 35 JP2 Clear CMOS jumper 36 U50 irmc chipset 37 CN4 PCI Express x8 expansion slot (low-profile, half-length) 38 CN8 PCI Express x8 expansion slot (standard, half-length) 39 U39 Broadcom BCM5708C NetXtreme Gigabit Ethernet controller 24 Technical Manual D2671 (RX200 S4)

25 Features Ports and indicators External ports and indicators Figure 5: External ports and indicators of the system board 1 PS/2 keyboard port (violet) 6 USB ports 2 PS/2 mouse port (green) 7 Serial port COM 3 GbE LAN port 1 (also for irmc server management function) 8 Video port (blue) 4 ID indicator (blue LED) 9 GbE LAN port 2 5 Global error/css LED indicator(bicolor LED: amber/yellow) 10 Service LAN port (for irmc server management function) D2671 (RX200 S4) Technical Manual 25

26 Ports and indicators Features LEDs Indicator CSS/Global Error (top) ID (bottom) Meaning Remains dark when the system is OK. No service case or critical event has occurred. Flashes yellow when an error has occurred which you can rectify yourself in the context of the CSS strategy. You can obtain details relating to the error on the server s Server View Local Service Panel or in ServerView S2. Steady yellow signal when a prefailure event has been detected for a CSS component. You can obtain details relating to the event in the System Event Log or in ServerView. The indicator is also bright in standby mode. Flashes orange when a critical event has occurred. You can obtain details relating to the event in the BIOS setup, in the System Event Log or in ServerView. The indicator also flashes in standby mode. Steady orange signal when a prefailure event has been detected for a non-css component. You can obtain details relating to the event in the System Event Log or in ServerView. The indicator is also bright in standby mode. After a power failure the display is activated following a restart, provided the event is not serious. When the ID key is pressed, the ID indicators at the front and back of the server flash synchronously. Steady blue signal if the system was selected by pressing the ID key. Pressing the key again deactivates the indicator. The ID indicator can also be activated via ServerView or its status is reported to ServerView. 26 Technical Manual D2671 (RX200 S4)

27 Features Ports and indicators LAN ports The system board is equipped with two Gigabit Ethernet Controllers of the type Broadcom BCM5708C NetXtreme. This LAN controller supports transmission rates of10 Mbit/s, 100 Mbit/s and 1 Gbit/s. The LAN controller also supports WOL functionality by means of Magic Packet. It is also possible to start a system via a LAN without a separate boot hard disk drive. PXE is supported here. The separate service LAN port is used as a management interface (irmc S2) and is prepared for operation with RemoteView. Optionally LAN port 1 can also be used for irmc server management. Each LAN port has two LEDs which display the speed of the connection and its status: Figure 6: LAN indicators of the system board Pos. Indicator Description 1 LAN activity (standard LAN) Steady green signal when a LAN connection exists. Remains dark when no LAN connection exists. Flashes green when LAN transfer takes place. 2 LAN transfer rate (standard LAN) Flashes yellow in the event of a LAN transfer rate of 1 Gbps. Steady green signal in the event of a LAN transfer rate of 100 Mbps. Remains dark in the event of a LAN transfer rate of 10 Mbps. D2671 (RX200 S4) Technical Manual 27

28 Ports and indicators Features Pos. Indicator Description 3 LAN activity (service LAN) 4 LAN transfer rate (service LAN) Steady green signal when a LAN connection exists. Remains dark when no LAN connection exists. Flashes green when LAN transfer takes place. Steady green signal in the event of a LAN transfer rate of100 Mbps. Remains dark in the event of a LAN transfer rate of 10 Mbps. 28 Technical Manual D2671 (RX200 S4)

29 Features Ports and indicators Internal diagnostic LEDs indicators Figure 7: Diagnostic elements on the system board (above) and fan board (below) D2671 (RX200 S4) Technical Manual 29

30 Ports and indicators Features Pos. Description 1 DIMM diagnostic LED indicators 2 Processor diagnostic LED indicators 3 PCI diagnostic LED indicators 4 Diagnostic LED button 5 System fan diagnostic LED indicators If no supply voltage is available, diagnostic LEDs help you to locate faulty components on the system board quickly. Ê Press the diagnostics button to locate faulty components when the associated diagnostic LED(s) go bright Settings with jumpers Clear CMOS jumper (JP2) Figure 8: Position of the jumpers Pos. Description 1-2 Normal, not clear CMOS settings (default setting) 2-3 Clear CMOS settings and restore default settings 30 Technical Manual D2671 (RX200 S4)

31 Features Ports and indicators Proceed as follows to delete the CMOS settings: Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Ê Create a backup of all the data. Shut down the server. Remove all power and connection cables. Remove the housing cover. Remove the PCI Riser card and, if required, all the additional cards which hinder access to jumper JP2 (Clear CMOS). Remove jumper JP2 from position 1-2 and insert it in position 2-3 for 20 to 30 seconds. Insert jumper JP2 in position 1-2 again. Insert all the expansion cards and the PCI Riser card again. Close the server s housing cover. Connect all the power and connection cables again. Switch the server on again. During the POST process press [F2] in order to enter the Setup Utility. Press [F9] to set the system defaults. Press [F10] to save your changes and to exit the Setup Utility. D2671 (RX200 S4) Technical Manual 31

32 Ports and indicators Features System configuration switch (DIP switch S1) Figure 9: Position of the system configuration switch S1 Switches Function Status Description S1-1 BIOS recovery On Boot block enabled Off Normal boot S1-2 Skip BIOS password On Password disabled query Off Password enabled S1-3 BIOS write-protect On BIOS can only be read Off BIOS can both be read and written to S1-4 CMOS clear On Clear CMOS settings and restore system defaults Off Normal CMOS settings I Switch status indicated in bold text is the default setting. 32 Technical Manual D2671 (RX200 S4)

33 4 Replacing the lithium battery In order to save the system information permanently, a lithium battery is installed to provide the CMOS-memory with a current. When the charge is too low or the battery is empty, a corresponding error message is provided. The lithium battery must then be replaced. V The lithium battery must be replaced with an identical battery or a battery type recommended by the manufacturer (CR2450). Do not throw lithium batteries into the trashcan. It must be disposed of in accordance with local regulations concerning special waste. Make sure that you insert the battery the right way round. The plus pole must be on the top! Figure 10: Replacing the lithium battery Ê Press the locking spring into direction of of the arrow (1), so that the lithiumbattery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). D2671 (RX200 S4) Technical Manual 33

34

35 Abbreviations The technical terms and abbreviations given below represent only a selection of the full list of common technical terms and abbreviations. Not all technical terms and abbreviations listed here are valid for the described system board. ACPI Advanced Configuration and Power Managament Interface ASSR Automatic Server Recovery and Restart ATA BBU BIOS BMC Advanced Technology Attachment Battery Backup Unit Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM CPU CRU CSS COMmunication port Central Processing Unit Customer Replaceable Unit Customer Self Service D2671 (RX200 S4) Technical Manual 35

36 Abbreviations DDR Double Data Rate DIMM Dual In-line Memory Module DIP DMI Dual In-line Package Desktop Management Interface DRAM Dynamic Random Access Memory ECC Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic EVRD Enterprise VRD FWH HPC I 2 C ICE Firmware Hub Hot plug Controller Inter Integrated Circuit In Circuit Emulation 36 Technical Manual D2671 (RX200 S4)

37 Abbreviations IDE IME IOOP IPMB IPMI irmc IRQ LAN LED MCH MPS NMI NOS ODD Integrated (intelligent) Drive Electronics Integrated Mirroring Enhanced Intelligent Organisation Of PCI Intelligent Platform Management Bus Intelligent Platform Management Interface Integrated Remote Management Controller Interrupt Request Local Area Network Light Emitting Diode Memory Controller Hub Multi Processor Specification Non-maskable Interrupt Network Operating System Optical Disc Drive D2671 (RX200 S4) Technical Manual 37

38 Abbreviations OEM OHCI OS PCI PDA PIO PLD Original Equipment Manufacturer Open Host Controller Interfache Operating System Peripheral Components Interconnect Prefailure Detection and Analysis Programmed Input Output Programmable Logic Device PS(U) Power Supply (Unit) PWM PXE RAID RSB RST RTC Puls Wide Modulation Preboot execution Environment Redundant Array if Inexpensive Disks Remote Service Board ReSeT Real Time Clock 38 Technical Manual D2671 (RX200 S4)

39 Abbreviations SAS SATA SCSI Serial Attached SCSI Serial Advanced Technology Attachment Small Computer Systems Interfache SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide SMB SMM SMP UHCI USB VGA VRD VRM System Management Bus Server Management Mode Symmetrically Multi Processing Unified Host Controller Interface Universal Serial Bus Video Graphics Adapter Voltage Regulator Down Voltage Regulator Module D2671 (RX200 S4) Technical Manual 39

40 Abbreviations WfM WOL Wired for Management Wake (up) On LAN 40 Technical Manual D2671 (RX200 S4)

41 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Computers. This new subsidiary of Fujitsu has been renamed Fujitsu Technology Solutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed. Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions. Contact and support addresses will now be offered by Fujitsu Technology Solutions and have the The Internet pages of Fujitsu Technology Solutions are available at and the user documentation at Copyright Fujitsu Technology Solutions, 2009 Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seitdem den Namen Fujitsu Technology Solutions. Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion. Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind. Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Die Internetseiten von Fujitsu Technology Solutions finden Sie unter und unter finden Sie die Benutzerdokumentation. Copyright Fujitsu Technology Solutions, 2009

The activities described in these upgrade instructions may only be performed by engineers or maintenance/technical staff.

The activities described in these upgrade instructions may only be performed by engineers or maintenance/technical staff. Introduction The upgrade instructions show how to remove the standard power supply and replace it with a hotplug power supply. The following steps only apply to the PRIMERGY 400 and 00 tower servers.!

More information

System Board D2786 for RX200 S5. Technical Manual

System Board D2786 for RX200 S5. Technical Manual System Board D2786 for RX200 S5 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

System Board D2559 for TX150 S6. Technical Manual

System Board D2559 for TX150 S6. Technical Manual System Board D2559 for TX150 S6 Technical Manual Edition November 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

System Board D2785 for TX120 S2. Technical Manual

System Board D2785 for TX120 S2. Technical Manual System Board D2785 for TX120 S2 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

System board D2020 for Econel 200

System board D2020 for Econel 200 Produktfamilie System board D2020 for Econel 200 Technical manual Redakteur Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-??? Fax: (++49)

More information

System board D2004 for RX100 S3

System board D2004 for RX100 S3 PRIMERGY System board D2004 for RX100 S3 Technical manual Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49) 700

More information

PRIMERGY S40-DF Capacity Extension

PRIMERGY S40-DF Capacity Extension Server PRIMERGY S40-DF Capacity Extension Xenia Fierley Siemens Nixdorf Informationssysteme AG ICP CS PS QM 3 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 636-47896 Fax: 0 700 /

More information

System Board D2619 for RX/TX300 S5. Technical Manual

System Board D2619 for RX/TX300 S5. Technical Manual System Board D2619 for RX/TX300 S5 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

This symbol is followed by supplementary information, remarks and tips.

This symbol is followed by supplementary information, remarks and tips. Introduction This Technical Manual describes the system boards of the PRIMERGY 870 server systems, which can be equipped with up to four Intel Xeon processors. You may find further information in the description

More information

FibreCAT TXF Backup Subsystem. Service Supplement

FibreCAT TXF Backup Subsystem. Service Supplement FibreCAT TXF Backup Subsystem Service Supplement Edition October 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

chipdisk for RemoteView

chipdisk for RemoteView PRIMERGY chipdisk for RemoteView Xenia Fierley Siemens Nixdorf Informationssysteme AG Primergy 81730 Munich e-mail: Internet:DOCetc@mchp.siemens.de Tel.: (089) 636-47896 Fax: (++ 49) 89 6 36-4 87 17 U41102-J-Z156-1-74

More information

System Board D3031 for PRIMERGY RX200 S6

System Board D3031 for PRIMERGY RX200 S6 Technical Manual - English System Board D3031 for PRIMERGY RX200 S6 Technical Manual Edition August 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

System Board D3034 for PRIMERGY RX100 S7

System Board D3034 for PRIMERGY RX100 S7 Technical Manual - English System Board D3034 for PRIMERGY RX100 S7 Technical Manual Edition August 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

PRIMERGY BX630 S2 Scalable Server Blade. Options Guide

PRIMERGY BX630 S2 Scalable Server Blade. Options Guide PRIMERGY BX630 S2 Scalable Server Blade Options Guide Edition October 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Fujitsu Siemens Computers GmbH DRV (BS2000/OSD) Version 3.1A November 2005 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Release Notice DRV V3.1A 1 General 2 1.1

More information

Produktfamilie PRIMERGY RX200 S2

Produktfamilie PRIMERGY RX200 S2 Produktfamilie PRIMERGY RX200 S2 D1790 Setup Utility Hans-Joachim Kneba Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: 05251/8-14865 Fax: (++49)

More information

System Board D2870 for PRIMERGY RX600 S5

System Board D2870 for PRIMERGY RX600 S5 Technical Manual - English System Board D2870 for PRIMERGY RX600 S5 Technical Manual April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC) User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Last Edition August 2017 Comments Suggestions Corrections The User Documentation Department would

More information

System Board D2799 for PRIMERGY TX200 S6

System Board D2799 for PRIMERGY TX200 S6 Technical Manual - English System Board D2799 for PRIMERGY TX200 S6 Technical Manual Edition July 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

WebTransactions V7.1. Supplement

WebTransactions V7.1. Supplement WebTransactions V7.1 Supplement Edition: December 2006 This manual describes the new functions in WebTransactions V7.1. It is intended to supplement the WebTransactions V7.0 manuals. Comments Suggestions

More information

System Board D2119 for RX300 S3

System Board D2119 for RX300 S3 PRIMERGY System Board D2119 for RX300 S3 Technical Manual Martin Jung Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-154 Fax: (++49) 700

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2008 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2008 All rights reserved Fujitsu Siemens Computers GmbH XHCS-SYS (BS2000/OSD) Version 2.0A June 2008 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2008 All rights reserved Release Notice XHCS-SYS V2.0A 1 General

More information

PRIMERGY Econel 200 S2 Server

PRIMERGY Econel 200 S2 Server PRIMERGY PRIMERGY Econel 200 S2 Server Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49) 700

More information

System Board D2129 for TX300 S3

System Board D2129 for TX300 S3 PRIMERGY System Board D2129 for TX300 S3 Technical Manual Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49)

More information

FUJITSU SIEMENS COMPUTERS. Release Notice PCMX (LINUX-S390) V6.0A. Table of Contents

FUJITSU SIEMENS COMPUTERS. Release Notice PCMX (LINUX-S390) V6.0A. Table of Contents FUJITSU SIEMENS COMPUTERS Release Notice PCMX (LINUX-S390) V6.0A Table of Contents 1 General 1.1 Documentation 2 Notes on product use 2.1 Software/hardware configuration 2.1.1 Operating system 2.2 Resource

More information

PRIMERGY SX650 Storage Blade. Operating Manual

PRIMERGY SX650 Storage Blade. Operating Manual PRIMERGY SX650 Storage Blade Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

PRIMERGY BX920 S1 Server-Blade. Service Supplement

PRIMERGY BX920 S1 Server-Blade. Service Supplement PRIMERGY BX920 S1 Server-Blade Service Supplement Edition April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY RX100 S3 Server System

PRIMERGY RX100 S3 Server System PRIMERGY PRIMERGY RX100 S3 Server System Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49)

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Fujitsu Siemens Computers GmbH SM2-TOOLS (BS2000/OSD) Version 7.5A Juli 2006 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Release Notice SM2-TOOLS V7.5A 1 General

More information

R E L E A S E N O T I C E C O S M O S T O O L S V A. (c) Fujitsu Siemens Computers GmbH 2001

R E L E A S E N O T I C E C O S M O S T O O L S V A. (c) Fujitsu Siemens Computers GmbH 2001 R E L E A S E N O T I C E C O S M O S T O O L S V 1 4. 0 A (c) Fujitsu Siemens Computers GmbH 2001 Word and Excel are registered trademarks of Microsoft Postscript is a registered trademark of Adobe Contents

More information

PRIMERGY TX200 S3 Server

PRIMERGY TX200 S3 Server PRIMERGY PRIMERGY TX200 S3 Server Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700

More information

PRIMERGY BX630 S2 Scalable Server-Blade. Service Supplement

PRIMERGY BX630 S2 Scalable Server-Blade. Service Supplement PRIMERGY BX630 S2 Scalable Server-Blade Service Supplement Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

PRIMERGY RX200 S3 Server. Options Guide

PRIMERGY RX200 S3 Server. Options Guide PRIMERGY RX200 S3 Server Options Guide Edition August 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY BX630 Scalable Server Blade

PRIMERGY BX630 Scalable Server Blade PRIMERGY PRIMERGY BX630 Scalable Server Blade Service Supplement Redakteur Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-??? Fax:

More information

PRIMERGY Econel 100 Server System

PRIMERGY Econel 100 Server System PRIMERGY PRIMERGY Econel 100 Server System Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 89) 61 001-155 Fax:

More information

PRIMERGY TX150 S5 Server

PRIMERGY TX150 S5 Server PRIMERGY PRIMERGY TX150 S5 Server Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2004 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2004 All rights reserved Fujitsu Siemens Computers GmbH A I D Version 3.1 November 2004 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2004 All rights reserved Release Notice AID V3.1 1 General....................

More information

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Standard server node for PRIMERGY CX400 M1 multi-node server system

More information

PRIMERGY BX620 S3 2-way Server Blade

PRIMERGY BX620 S3 2-way Server Blade PRIMERGY PRIMERGY BX620 S3 2-way Server Blade Options Guide Walter Dick Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 52 51)14888-12 Fax:

More information

PRIMERGY TX120 S2 Server. Service Supplement

PRIMERGY TX120 S2 Server. Service Supplement PRIMERGY TX120 S2 Server Service Supplement Edition July 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Fujitsu Siemens Computers. internet Value Edition. Version 1.0B. July Release Notice

Fujitsu Siemens Computers. internet Value Edition. Version 1.0B. July Release Notice Fujitsu Siemens Computers internet Value Edition Version 1.0B July 2002 Release Notice Copyright (C) Fujitsu Siemens Computers 2002 All rights reserved Release Notice internet Value Edition V1.0B 1 General.....................

More information

PRIMERGY Econel 100 Server System

PRIMERGY Econel 100 Server System PRIMERGY PRIMERGY Econel 100 Server System Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 89) 61 001-155 Fax: (++49)

More information

PRIMERGY RX300 S2 Server System

PRIMERGY RX300 S2 Server System PRIMERGY PRIMERGY RX300 S2 Server System Monika Spanjaart Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001160 Fax: (++49) 700 / 372 00000

More information

STREAMER VXA /320 GB

STREAMER VXA /320 GB Operating Manual English STREAMER VXA-320 160/320 GB Are there...... any technical problems or other questions you need clarified? Please contact our Help Desk (see warranty card). The latest information

More information

Fujitsu PRIMERGY TX100 S2 Server

Fujitsu PRIMERGY TX100 S2 Server Datasheet Fujitsu PRIMERGY TX100 S2 Server Enter the world of servers - now with 0-Watt functionality PRIMERGY TX industry standard tower servers: efficient, rock solid, record-breaking performance. PRIMERGY

More information

Technical Manual. Mainboard D1483. English

Technical Manual. Mainboard D1483. English answers 2 Technical Manual Mainboard D1483 English Are there...... any technical problems or other questions you need clarified? Please contact: your sales partner your sales outlet You will find further

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2005 *3 All rights reserved *3

Copyright (C) Fujitsu Siemens Computers GmbH 2005 *3 All rights reserved *3 Fujitsu Siemens Computers GmbH CRTE (BS2000/OSD) Version 2.4C *4 October 2005 *4 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 *3 All rights reserved *3 Release Notice CRTE V2.4C 1 General.....................

More information

Streamer DAT160 Half-Height 80GB/160GB, USB 2.0

Streamer DAT160 Half-Height 80GB/160GB, USB 2.0 User Guide English Streamer DAT160 Half-Height 80GB/160GB, USB 2.0 Streamer DAT160 Half-Height 80GB/160GB, USB 2.0 User Guide Edition November 2008 Comments Suggestions Corrections The User Documentation

More information

Using Egenera Virtualized Boot Services

Using Egenera Virtualized Boot Services Using Egenera Virtualized Boot Services For BladeFrame BF400 S2 and BladeFrame BF200 Document Number 432-SB0045 September 2008 EVBS1.0_BF_1 Copyright Copyright 2008 Egenera, Inc. All rights reserved. This

More information

PRIMERGY RX300 S4. Options Guide

PRIMERGY RX300 S4. Options Guide PRIMERGY RX300 S4 Options Guide Edition June 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

MITAC Desktop Board PD10TI Product Guide

MITAC Desktop Board PD10TI Product Guide MITAC Desktop Board PD10TI Product Guide Desktop Board Features This chapter briefly describes the main features of MITAC Desktop Board PD10TI. Table 1 summarizes the features of the Desktop Board. TABLE

More information

PRIMERGY RX300 S5. Operating manual

PRIMERGY RX300 S5. Operating manual PRIMERGY RX300 S5 Operating manual Edition september 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Acer AR320 F2 Specifications

Acer AR320 F2 Specifications Acer AR320 F2 Specifications What Product overview The AR320 F2 single-socket server delivers great performance and enterprise-level scalability in a space-saving design. Proactive management utilities

More information

MITAC Desktop Board PD12TI Product Guide

MITAC Desktop Board PD12TI Product Guide MITAC Desktop Board PD12TI Product Guide Desktop Board Features This chapter briefly describes the main features of MITAC Desktop Board PD12TI. Table 1 summarizes the features of the Desktop Board. Table

More information

Modular RAID Controllers

Modular RAID Controllers User Guide - English Modular RAID Controllers "RAID 0/1 SAS based on LSI MegaRAID" "RAID 5/6 SAS based on LSI MegaRAID" "RAID Ctrl SAS 6G 0/1 (D2607)" "RAID Ctrl SAS 6G 5/6 512MB (D2616)" "PY SAS RAID

More information

Fujitsu PRIMERGY BX920 S1 Dual-Socket Server

Fujitsu PRIMERGY BX920 S1 Dual-Socket Server Datasheet Fujitsu PRIMERGY BX920 S1 Dual-Socket Server Blade All-around server blade packing lots of computing power in small form factor. The PRIMERGY BX Blade Servers are the ideal choice for data center

More information

PRIMERGY TX120 Server. Operating Manual

PRIMERGY TX120 Server. Operating Manual PRIMERGY TX120 Server Operating Manual Edition July 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY TX120 S2 Server. Operating manual

PRIMERGY TX120 S2 Server. Operating manual PRIMERGY TX120 S2 Server Operating manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY Econel 200 S2 Server. Operating manual

PRIMERGY Econel 200 S2 Server. Operating manual PRIMERGY Econel 200 S2 Server Operating manual Edition March 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY BX630 S2 Scalable Server Blade. Operating Manual

PRIMERGY BX630 S2 Scalable Server Blade. Operating Manual PRIMERGY BX630 S2 Scalable Server Blade Operating Manual Edition October 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

PRIMERGY RX200 S5. Operating Manual

PRIMERGY RX200 S5. Operating Manual PRIMERGY RX200 S5 Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY RX300 S5. Service Supplement

PRIMERGY RX300 S5. Service Supplement PRIMERGY RX300 S5 Service Supplement Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY BX600 10GbE LAN I/O Module (PCIe)

PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Reference Guide PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Microsoft Windows Server 2003 iscsiselect Reference Guide English PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Microsoft Windows Server 2003 iscsiselect

More information

Data Sheet ESPRIMO P2550. Your immediately available Office PC ESPRIMO P2550

Data Sheet ESPRIMO P2550. Your immediately available Office PC ESPRIMO P2550 Data Sheet Your immediately available Office PC Issue: October 2009 The is designed for price-conscious customers and is equipped with state-of-the-art standard Intel technology. These systems meet every

More information

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server Expandable all-round server for

More information

PRIMERGY 670 Converting Guide

PRIMERGY 670 Converting Guide PRIMERGY 670 Converting Guide Server Systems A26361-K531-Z101-1-7419 Edition March 1999 Copyright and Trademarks Intel and Pentium are registered trademarks of Intel Corporation, USA. NetWare and Novell

More information

NEC Express5800/R120e-1M System Configuration Guide

NEC Express5800/R120e-1M System Configuration Guide NEC Express5800/R120e-1M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Data Sheet Fujitsu PRIMERGY RX4770 M2 Server

Data Sheet Fujitsu PRIMERGY RX4770 M2 Server Data Sheet Fujitsu PRIMERGY RX4770 M2 Server Data Sheet Fujitsu PRIMERGY RX4770 M2 Server Platform of choice for business critical backend services with superior levels of performance and reliability enhanced

More information

Acer AR320 F1 specifications

Acer AR320 F1 specifications Product overview The AR320 F1 is a single-socket server that delivers great performance and enterprise-level scalability in a space-saving design. Driven by a robust processor, huge memory footprint, and

More information

Data Sheet Fujitsu PRIMERGY TX1330 M2 Server

Data Sheet Fujitsu PRIMERGY TX1330 M2 Server Data Sheet Fujitsu PRIMERGY TX1330 M2 Server Expandable all-round server for SMEs PRIMERGY TX1330 M2 The FUJITSU Server PRIMERGY TX1330 M2 is the ideal robust, expandable, and cost-efficient server for

More information

answers SCENIC P / SCENICO P / SCENIC Edition X100 Getting Started English

answers SCENIC P / SCENICO P / SCENIC Edition X100 Getting Started English answers 2 Getting Started SCENIC P / SCENICO P / SCENIC Edition X100 English Are there...... any technical problems or other questions which you would like to be clarified? Please contact: your sales partner

More information

Altos R320 F3 Specifications. Product overview. Product views. Internal view

Altos R320 F3 Specifications. Product overview. Product views. Internal view Product overview The Altos R320 F3 single-socket 1U rack server delivers great performance and enterprise-level scalability in a space-saving design. Proactive management utilities effectively handle SMB

More information

Cisco MCS 7835-H2 Unified Communications Manager Appliance

Cisco MCS 7835-H2 Unified Communications Manager Appliance Cisco MCS 7835-H2 Unified Communications Manager Appliance Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks enabling easy collaboration

More information

Acer AT310 F2 Specifications

Acer AT310 F2 Specifications Product overview The AT310 F2 delivers proactive manageability tools matched by best price-performance technology ideal for SMB and branch office business operations. This single-socket tower server also

More information

Technical Specifications

Technical Specifications Technical s 6 NOTE: Offerings may vary by region. The following specifications are only those required by law to ship with your computer. For comprehensive specification of your computer go to s section

More information

Baseboard D3144, CPUMEMR D3145, PCIR D3146 for PRIMERGY RX900 S2

Baseboard D3144, CPUMEMR D3145, PCIR D3146 for PRIMERGY RX900 S2 Technical Manual - English Baseboard D44, MEMR D45, PCIR D46 for PRIMERGY RX9 S Technical Manual Edition May Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

CAF-1000 Series Communication Appliance. User s Manual Revision: 1.0

CAF-1000 Series Communication Appliance. User s Manual Revision: 1.0 CAF-1000 Series Communication Appliance User s Manual Revision: 1.0 CE This certificate of conformity of COS-0906 series with actual required safety standards in accordance with 89/366 ECC-EMC Directive

More information

PRIMERGY Econel 230R S1 Server. Operating manual

PRIMERGY Econel 230R S1 Server. Operating manual PRIMERGY Econel 230R S1 Server Operating manual Edition May 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Strong Performance and Cluster

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Product Specification. Shuttle XPC System J4 4100BA. Economic entry-level Mini-PC. Feature Highlights.

Product Specification. Shuttle XPC System J4 4100BA. Economic entry-level Mini-PC. Feature Highlights. Economic entry-level Mini-PC The Shuttle XPC J4 4100BA is a Mini-PC with Intel Pentium processor with Socket 775. The new J4 front panel comes with a removable acrylic plate which allows to create individual

More information

PRIMERGY TX200 S4 Server. Operating manual

PRIMERGY TX200 S4 Server. Operating manual PRIMERGY TX200 S4 Server Operating manual Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade

Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade Universal dual socket server blade with high computing and I/O performance in a small form factor The PRIMERGY BX Blade Servers are the ideal

More information

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191C2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de

More information

LAN Manager/X V2.2. (SINIX) SNMP Service. System Administator's Guide

LAN Manager/X V2.2. (SINIX) SNMP Service. System Administator's Guide LAN Manager/X V2.2 (SINIX) SNMP Service System Administator's Guide Is there anything you want to tell us about this manual? Please send us your comments, quoting the order number of the manual. Siemens

More information

Altos T310 F3 Specifications

Altos T310 F3 Specifications Product overview The Altos T310 F3 delivers proactive management tools matched by best priceperformance technology ideal for SMB and branch office operations. This singlesocket tower server features an

More information

Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node

Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node Datasheet for Red Hat certification Standard server node for PRIMERGY

More information

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191V2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet: http://www.ipcomm.de

More information

Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade

Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade Data Sheet FUJITSU Server PRIMERGY BX924 S3 Dual Socket Server Blade Datasheet for Red Hat certification High-end server blade with

More information

Cisco MCS 7845-H1 Unified CallManager Appliance

Cisco MCS 7845-H1 Unified CallManager Appliance Data Sheet Cisco MCS 7845-H1 Unified CallManager Appliance THIS PRODUCT IS NO LONGER BEING SOLD AND MIGHT NOT BE SUPPORTED. READ THE END-OF-LIFE NOTICE TO LEARN ABOUT POTENTIAL REPLACEMENT PRODUCTS AND

More information

PRIMERGY RX200 S4 Server. Operating manual

PRIMERGY RX200 S4 Server. Operating manual PRIMERGY RX200 S4 Server Operating manual Edition January 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server Expandable all-round server for SMEs PRIMERGY TX1330 M1 The PRIMERGY TX1330 M1 is the

More information

PRIMERGY RX300 S3 Server. Options Guide

PRIMERGY RX300 S3 Server. Options Guide PRIMERGY RX300 S3 Server Options Guide Edition June 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Acer AT110 F2 Specifications

Acer AT110 F2 Specifications Product overview The AT110 F2 delivers true server-class features and expandability along with best price-performance technology to assure the success of your small-sized business. This single-socket tower

More information

High Performance Computing

High Performance Computing 21 High Performance Computing High Performance Computing Systems 21-2 HPC-1420-ISSE Robust 1U Intel Quad Core Xeon Server with Innovative Cable-less Design 21-3 HPC-2820-ISSE 2U Intel Quad Core Xeon Server

More information

NEC Express5800/R120d-2M Configuration Guide

NEC Express5800/R120d-2M Configuration Guide NEC Express5800/R120d-2M Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper

More information

Emanate Master 1.3. Readme. Edition June 2000

Emanate Master 1.3. Readme. Edition June 2000 Solaris Emanate Master 1.3 Readme Redakteur Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 636-00000 Fax: (++49) 700 / 372 00001 Bestellnummer

More information

PRIMERGY RX600 S4 Server. Service Supplement

PRIMERGY RX600 S4 Server. Service Supplement PRIMERGY RX600 S4 Server Service Supplement Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

NEC Express5800/R120h-2M System Configuration Guide

NEC Express5800/R120h-2M System Configuration Guide NEC Express5800/R120h-2M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

PRIMERGY TX200 S3 Server. Operating Manual

PRIMERGY TX200 S3 Server. Operating Manual PRIMERGY TX200 S3 Server Operating Manual Edition June 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information