System Board D2785 for TX120 S2. Technical Manual

Size: px
Start display at page:

Download "System Board D2785 for TX120 S2. Technical Manual"

Transcription

1 System Board D2785 for TX120 S2 Technical Manual Edition April 2009

2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by to Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2009 FujitsuTechnologySolutionsGmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.

3 Contents 1 Introduction Important notes Notes on safety CE certificate of conformity ENERGY STAR Environmental protection Features Overview Main memory PCI bus Screen resolution Temperature / system monitoring Connectors and indicators System board Connector panel Jumpers Replacing the lithium battery Abbreviations D2785 (TX120 S2) Technical Manual

4

5 1 Introduction This technical manual describes the system board D2785, which is equipped with one Intel processor. You will find further information in the manual BIOS Setup. Further information about drivers is provided in the readme files on the hard disk, or on the supplied CDs/DVDs. Notational conventions The meanings of the symbols and fonts used in this manual are as follows: Text in talics Text in fixed font Text in semi-bold fixed font [Key symbol] Quotation marks Ê V CAUTION! I indicates commands or menu items. indicates system output on the monitor. indicates values to be entered through the keyboard. indicates keys according to their representation on the keyboard. If capital letters are to be entered explicitly, then the Shift key is shown, e.g. [SHIFT] - [A] for A. If two keys need to be pressed at the same time, then this is shown by placing a hyphen between the two key symbols. indicate names of chapters and terms that are being emphasized. describes activities that must be performed in the order shown. describes activities that must be performed in the order shown. indicates additional information, notes and tips. Table 1: Notational conventions D2785 (TX120 S2) Technical Manual 5

6

7 2 Important notes In this chapter you will find essential information regarding safety when working with the system board. V CAUTION! With the system board installed you must open the system to access the system board. How to access the system board of your system is described in the appropriate service supplement. When handling the system board, refer to the specific notes on safety in the operating manual and/or service supplement for the respective server. 2.1 Notes on safety V CAUTION! The actions described in these instructions should only be performed by authorized, qualified personnel. Equipment repairs should only be performed by qualified staff. Any failure to observe the guidelines in this manual, and any unauthorized openings and improper repairs could expose the user to risks (electric shock, fire hazards) and could also damage the equipment. Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability. Transport the device only in the antistatic original packaging or in packaging that protects it from knocks and jolts. Only install expansions that are allowed for the system board. If you install other expansions, you may damage the requirements and rules governing safety and electromagnetic compatibility or your system. Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. D2785 (TX120 S2) Technical Manual 7

8 Notes on safety Important notes V CAUTION! Components can become very hot during operation. Ensure you do not touch components when making extensions to the system board. There is a danger of burns! Transmission lines to peripheral devices must be adequately shielded. To the LAN wiring the requirements apply in accordance with the standards EN and EN /2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 MBps Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC are to be considered. Never connect or disconnect data transmission lines during a storm (lightning hazard). Batteries V CAUTION! Incorrect replacement of lithium battery may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer. It is essential to observe the instructions in chapter Replacing the lithium battery. Modules with electrostatic-sensitive components Boards with electrostatic sensitive devices (ESD) are marked with the following label: Figure 1: ESD label 8 Technical Manual D2785 (TX120 S2)

9 Important notes Notes on safety When you handle components fitted with ESDs, you must observe the following points under all circumstances: You must always discharge yourself of static charges (e.g. by touching a grounded object) before working. The equipment and tools you use must be free of static charges. Shut-down the system and remove the power plug from the power socket before inserting or removing boards containing ESDs. Always hold boards with ESDs by their edges. Never touch pins or conductors on boards fitted with ESDs. Use a grounding cable designed for this purpose to connect yourself to the system unit as you install/deinstall the board. Place all components on a static-safe base. I You will find a detailed description for handling ESD components in the relevant European or international standards (EN , ANSI/ESD S20.20). Notes about boards During installation/deinstallation of the board, observe the specific instructions described in the service supplement for the respective server. Shut-down the system and remove the power plug from the power socket before you make modifications on an installed board. To prevent damage to the board, the components and conductors on it, please take great care when you insert or remove boards. Take great care to ensure that extension boards are slotted in straight, without damaging components or conductors on the board, or any other components, for example EMI spring contacts Be careful with the locking mechanisms (catches, centring pins etc.) when you replace the system board or components on it, for example memory modules or processors. Never use sharp objects (screw drivers) for leverage. D2785 (TX120 S2) Technical Manual 9

10 CE certificate of conformity Important notes 2.2 CE certificate of conformity The board complies with the requirements of the EC directives 2004/108/EC regarding Electromagnetic Compatibility and 2006/95/EC Low Voltage Directive. This is indicated by the CE marking (CE = Communauté Européenne). Compliance was tested in a typical PRIMERGY configuration. 2.3 ENERGY STAR In some particular configurations 1 the PRIMERGY TX120 S2 is equipped with a power management system which, in energysaving mode, reduces the power consumption to <65 W. The server thus satisfies the requirements of the U.S. Environmental Protection Agency (EPA). The EPA estimates that computer systems use around 5 % of all electricity in the office sector and that this figure is growing rapidly. If all computer systems and peripherals were placed in energy-saving mode when not in use, the overall savings in electricity could amount to some US $ 2 billion annually. These savings would also prevent the emission of 20 million tons of carbon dioxide into the atmosphere - equivalent to the emissions from 5 million automobiles. As an ENERGY STAR partner, Fujitsu Technology Solutions GmbH has determined that in some particular configurations this product meets the ENERGY STAR guidelines for energy efficiency. 1 These servers are always delivered with a particular setting in the BIOS setup. For details please see the manual D2785 BIOS Setup Utility for PRIMERGY TX120 S2 on the PRIMERGY ServerView Suite DVD Technical Manual D2785 (TX120 S2)

11 Important notes Environmental protection 2.4 Environmental protection Environmentally friendly product design and development This product has been designed in accordance with standards for environmentally friendly product design and development. This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account. This saves resources and thus reduces the harm done to the environment. Energy-saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work. Packaging information Do not throw away the packaging. You may need it later for transporting the system. If possible, the equipment should only be transported in its original packaging. Information on handling consumables Please dispose of batteries in accordance with local regulations. In accordance with EU directives, batteries must not be disposed of with unsorted domestic waste. They can be returned free of charge to the manufacturer, dealer or an authorized agent for recycling or disposal. All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants: Cd Cadmium Hg Mercury Pb Lead Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them. D2785 (TX120 S2) Technical Manual 11

12 Environmental protection Important notes Returns, recycling and disposal Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu Technology Solutions branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D Paderborn Tel Fax The device must not be disposed of with domestic waste. This device is labeled in compliance with European directive 2002/96/EG on waste electrical and electronic equipment (WEEE). This directive sets the framework for returning and recycling used equipment and is valid across the EU. When returning your used device, please use the return and collection systems available to you. Further information can be found at 12 Technical Manual D2785 (TX120 S2)

13 3 Features 3.1 Overview Processors Intel Core TM 2 Duo processor P8400/T9400, 1066 MHz FSB 478 pin Micro FCPGA processor socket Main memory 4 slots for main memory DDR2 533/667 MHz (unbuffered), SDRAM memory modules with 1 GB, 2 GB and 4 GB maximum 16 GB of main memory minimum 1 GB of main memory ECC multiple bit error detection and single bit error correction Chips on the system board Intel 5100 MCH (north bridge) chipset Intel 82801GR ICH9-R (south bridge) chipset SMC 8700C (for Service LAN) Intel ICH9-R integrated Gigabit Ethernet controller with Intel LM Flash EPROM for: local BIOS update via bootable USB device remote BIOS update via LAN Onboard irmc S2 Server Management controller with integrated graphic controller and associated service LAN connector ADT7462 temperature and system monitoring controller D2785 (TX120 S2) Technical Manual 13

14 Overview Features Internal connectors 1x front panel connector 1x ATX power supply connector 1x ATX 12V (CPU) power supply connector 2x system fan connectors 1x SATA connector 1x SATA MLC1 connector 1x SAS-LED connector 1x USB 2.0 connector (for an optional backup drive) 1x connector for the front side Service LAN connector External connectors Rear side: 1x serial interface (COM1) 1x VGA connector 1x RJ45 Service LAN connector 1x RJ45 LAN connector 5x USB 2.0 connectors Front side: 1x RJ45 Service LAN connector (optional) 2x USB 2.0 connectors Slots for expansion boards (low profile) 1 x PCI (32 Bit / 33 MHz) expansion slot 3 x PCI Express x8 expansion slots BIOS Phoenix System BIOS V 4.06 (Trusted Core) Environmental protection Battery in holder Form factor, slot compatibility list 260 mm x 305 mm 14 Technical Manual D2785 (TX120 S2)

15 Features Overview TPM (option) The system board can be equipped with a TPM (Trusted Platform Module) by the manufacturer or by an add-on kit. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption). The TPM is activated via the BIOS system (for more information, refer to the BIOS manual). V CAUTION! When using the TPM, note the program descriptions provided by the third party manufacturers. You must also create a backup of the TPM content. To do this, follow the third party manufacturer's instructions. Without this backup, if the TPM or the system board is faulty you will not be able to access your data. If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content. D2785 (TX120 S2) Technical Manual 15

16 Main memory Features 3.2 Main memory The system board supports up to 16 Gbyte main memory. 4 slots (2 memory banks with 2 modules) are available for the main memory. Each memory bank can be populated with 1 GB, 2 GB or 4 GB unbuffered DDR2 memory modules. Module population Channel B DIMM 1A DIMM 1B DIMM 2A DIMM 2B Channel A Figure 2: Detail - slots of the main memory If the memory modules are populated in pairs, each pair must consist of identical memory modules (2-way interleaved mode). The module capacity between pairs can differ: pair 1A/1B can be populated with two 1 GB memory modules and pair 2A/2B with two 2 GB memory modules. Following table shows the mandatory population order: Modes DIMM-1A DIMM-1B DIMM-2A DIMM-2B single channel populated empty empty empty dual channel populated populated empty empty single / dual channel 1 populated populated populated empty dual channel populated populated populated populated 1 The dual channel mode is only activated, if the memory size installed in the DIMM-2A slot is equal to the sum of the memory modules installed in the DIMM-1A and DIMM-1B slots. (e. g.: DIMM-1A=1GB, DIMM-1B=1GB, DIMM-2A=2GB) 16 Technical Manual D2785 (TX120 S2)

17 Features PCI bus 3.3 PCI bus PCI slots PCI slot 1 PCI slot 2 PCI slot 3 PCI slot 4 Figure 3: Detail - PCI slots PCI slot Description 1 PCI-Express x8 bus-slot 2 PCI-Express x8 bus-slot 3 32 bit PCI bus slot (32-Bit/33MHz) 4 PCI-Express x8 bus-slot PCI, PCI Express interrupts Each device connected to a PCI bus or PCI Express can use up to four interrupt signals depending on the functionality. PCI and PCI-X buses use four lines named INTA to INTD, typically connected to all devices on the bus in order to periodically balance interrupt load. An interrupt signal may thereby be used simultaneously by multiple devices (interrupt sharing). PCI Express devices send their interrupts through messages. This avoids restrictions in wiring. D2785 (TX120 S2) Technical Manual 17

18 Screen resolution Features The following interrupt signals are used in the system: Slot/device Property Interrupt signal VGA irmc S2 graphic Int B LAN Intel LM Int A Slot 1 PCIe x8 Int A, B, C, D Slot 2 PCIe x8 Int A, B, C, D Slot 3 PCI (33 MHz) Int A, B, C, D Slot 4 PCIe x8 Int A, B, C, D Assignment of the PCI interrupts If you select Auto in the BIOS setup, the interrupts are assigned automatically and no further settings are required. 3.4 Screen resolution Depending on the operating system used the screen resolutions in the following table refer to the Matrox graphic controller on the system board. The Matrox graphic controller is integrated in irmc S2 (integrated Remote Management Controller). Screen resolution Maximal refresh rate (Hz) Maximal colour depth 640x Bit 800x Bit 1024x Bit 1152x Bit 1280x Bit If you are using a different graphic controller, you will find details of supported screen resolutions in the documentation supplied with the graphic controller. 18 Technical Manual D2785 (TX120 S2)

19 Features Temperature / system monitoring 3.5 Temperature / system monitoring Temperature and system monitoring aim to reliably protect the computer hardware against damage caused by overheating. In addition, any unnecessary noise is also prevented by reducing the fan speed, and information is provided about the system status. The temperature and system monitoring are controlled by an onboard controller. The following functions are supported: Temperature monitoring Measurement of the processor and the inhouse temperature by an onboard sensor, measurement of the ambient temperature by a I²C temperature sensor. Fan monitoring Fans that are no longer available, blocked or sticky fans are detected. Fan control The fans are regulated according to temperature. Sensor monitoring The removal of, or a fault in, a temperature sensor is detected. Should this happen all fans monitored by this sensor run at maximum speed, to achieve the greatest possible protection of the hardware. Voltage monitoring When voltage exceeds warning level high or falls below warning level low an alert will be generated. System Event Log (SEL) All monitored events of the system board are recorded in the System Event Log. They could be retrieved after a reboot via ServerView. D2785 (TX120 S2) Technical Manual 19

20 Connectors and indicators Features 3.6 Connectors and indicators System board 1 2 FAN2 FRONT PANEL SYS CPU ATX 12V1 3 Upper BPL I2C CONN 4 DIMM 1A DIMM 1B DIMM 2A DIMM 2B Intel MCH Battery JP5 JP6 JP7 FRONT LAN FAN1 SYS ATX PWR1 Intel ICH9-R USB DRIVE SATA 9 JP3 10 irmc S2 PCI slot 1 PCI slot 2 PCI slot 3 PCI slot 4 JP2 SATA MLC1 Intel TPM 11 COM1 VGA Service LAN USB 7/8 LAN USB 3/4/6 Figure 4: Internal connectors of the system board D Technical Manual D2785 (TX120 S2)

21 Features Connectors and indicators No. Description 1 System fan 2 connector 2 Front panel connector 3 Power supply connector ATX (12 V / CPU) 4 SAS LED connector (HDD backplane) 5 Connector for Service LAN front side 6 System fan 1 connector 7 Power supply connector ATX 8 USB connector for optional backup drive 9 SATA connector 10 SATA MLC1 connector 11 Connector for TPM Onboard diagnostic LED VGA COM1 A irmc S2 Service LAN Figure 5: Detail - Diagnostic LED The LED has the following meaning: LED Indicator Meaning A green flashing irmc S2 is healthy D2785 (TX120 S2) Technical Manual 21

22 Connectors and indicators Features Connector panel Figure 6: Connector panel of the system board D2785 No. Description 1 Serial interfacecom1 (turquoise) 2 Monitor connector VGA (blue) 3 Service LAN connector 4 LAN connector 5 5x USB connectors (black) LAN connectors On this system board you will find a Gigabit Ethernet controller with Intel LM integrated in the Intel ICH9-R chipset. The Gigabit Ethernet controller supports the transfer rates of 10 Mbit/s, 100 Mbit/s and 1 Gbit/s. The LAN controller supports WOL function through Magic Package. It is also possible to boot a device without its own boot hard disk via LAN. Here PXE is supported. The separate service LAN connector of the irmc S2 is used as a management interface and is prepared for operation with the Remote Management. 22 Technical Manual D2785 (TX120 S2)

23 Features Connectors and indicators The LAN connectors are equipped with two LEDs (light emitting diode) indicating the transfer rate and the activity. Figure 7: LAN indicators No Indicator Description 1 LAN activity (service LAN) 2 LAN transfer rate (service LAN) 3 LAN activity (standard LAN) 4 LAN transfer rate (standard LAN) Steady green signal when a LAN connection exists. Remains dark when no LAN connection exists. Flashes green when LAN transfer takes place. Steady green signal in the event of a LAN transfer rate of100 Mbps. Remains dark in the event of a LAN transfer rate of 10 Mbps. Steady green signal when a LAN connection exists. Remains dark when no LAN connection exists. Flashes green when LAN transfer takes place. Flashes yellow in the event of a LAN transfer rate of 1 Gbps Steady green signal in the event of a LAN transfer rate of 100 Mbps. Remains dark in the event of a LAN transfer rate of 10 Mbps. D2785 (TX120 S2) Technical Manual 23

24 Connectors and indicators Features Jumpers CPU DIMM 1A DIMM 1B DIMM 2A DIMM 2B Intel MCH JP6 JP Battery JP5 Intel ICH9-R 4 JP3 irmc S2 PCI slot 1 PCI slot 2 PCI slot 3 PCI slot 4 JP2 Intel TPM 5 COM1 VGA Service LAN USB 7/8 LAN USB 3/4/6 Figure 8: Jumpers of the system board D Technical Manual D2785 (TX120 S2)

25 Features Connectors and indicators I The default setting for all jumpers is position 1-2. No. Print Function Setting Description 1 JP7 Power on 1-2 (standard) Power on by IPMI path 2-3 Power on by ICH9-R 2 JP6 Protected 1-2 (standard) RTC settings are not cleared. RTC 2-3 RTC settings are cleared. 3 JP5 Clear 1-2 (standard) CMOS settings are not cleared. CMOS 2-3 CMOS settings are cleared. 4 JP3 BIOS recovery 5 JP2 BIOS password recovery 1-2 (standard) The system is started with the system BIOS from the system board 2-3 The system boots from the Flash BIOS floppy disk (via an external USB floppy disk drive) and reprograms the system BIOS on the system board. 1-2 (standard) The password query is skipped. Passwords are deleted. 2-3 The password query is effective. D2785 (TX120 S2) Technical Manual 25

26

27 4 Replacing the lithium battery In order to save the system information permanently, a lithium battery is installed to provide the CMOS-memory with a current. When the charge is too low or the battery is empty, a corresponding error message is provided. The lithium battery must then be replaced. V ATTENTION! The lithium battery must be replaced with an identical battery or a battery type recommended by the manufacturer (CR2032). Do not throw lithium batteries into the trashcan. It must be disposed of in accordance with local regulations concerning special waste. Make sure that you insert the battery the right way round. The plus pole must be on the top! Figure 9: Replacing the lithium battery Ê Press the locking spring into direction of the arrow (1), so that the lithiumbattery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). D2785 (TX120 S2) Technical Manual 27

28

29 Abbreviations The technical terms and abbreviations given below represent only a selection of the full list of common technical terms and abbreviations. Not all technical terms and abbreviations listed here are valid for the described system board. ACPI Advanced Configuration and Power Interface ASR&R Automatic Server Recovery and Restart ATA BBU BIOS BMC Advanced Technology Attachment Battery Backup Unit Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM CRU CSS CPU COMmunication port Customer Replaceable Unit Customer Self Service Central Processing Unit D2785 (TX120 S2) Technical Manual 29

30 Abbreviations DDR Double Data Rate DIMM Dual In-line Memory Module DIP DMI DMA Dual In-line Package Desktop Management Interface Direct Memory Access DRAM Dynamic Random Access Memory ECC Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic ESD Electrostatic Discharge EVRD Enterprise Voltage Regulator Down FBD HDD Fully Buffered DIMM Hard Disk Drive 30 Technical Manual D2785 (TX120 S2)

31 Abbreviations HPC ICE IDE IME IOOP IPMB IPMI irmc LAN LED MCH MPS NMI NOS Hot-plug Controller In Circuit Emulation Integrated (intelligent) Drive Electronics Integrated Mirror Enhanced Intelligent Organization Of PCI Intelligent Platform Management Bus Intelligent Platform Management Interface integrated Remote Management Controller Local Area Network Light Emitting Diode Memory Controller Hub Multi Processor Specification Non Maskable Interrupt Network Operating System D2785 (TX120 S2) Technical Manual 31

32 Abbreviations NVRAM Non Volatile RAM ODD OEM OHCI OS PCI PDA PIO PLD Optical Disc Drive Original Equipment Manufacturer Open Host Controller Interface Operating System Peripheral Components Interconnect Prefailure Detection and Analyzing Programmed Input Output Programmable Logic Device POST Power-On Self Test PS(U) Power Supply (Unit) PWM PXE Puls Wide Modulation Preboot execution Environment RAID Redundant Array of Inexpensive Disks 32 Technical Manual D2785 (TX120 S2)

33 Abbreviations RAM RSB RST RTC SAS SATA SCSI Random Access Memory Remote Service Board ReSeT Real Time Clock Serial Attached SCSI Serial ATA Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide SHPC Standard Hot Plug Controller SMB SMM SMP System Management Bus Server Management Mode Symmetrically Multi Processing D2785 (TX120 S2) Technical Manual 33

34 Abbreviations SSD TPM UHCI USB VGA VRD VRM WfM WOL Solid-State Drive Trusted Platform Module Unified Host Controller Interface Universal Serial Bus Video Graphics Adapter Voltage Regulator Down Voltage Regulator Module Wired for Management Wake up On LAN 34 Technical Manual D2785 (TX120 S2)

35 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Computers. This new subsidiary of Fujitsu has been renamed Fujitsu Technology Solutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed. Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions. Contact and support addresses will now be offered by Fujitsu Technology Solutions and have the The Internet pages of Fujitsu Technology Solutions are available at and the user documentation at Copyright Fujitsu Technology Solutions, 2009 Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seitdem den Namen Fujitsu Technology Solutions. Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion. Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind. Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Die Internetseiten von Fujitsu Technology Solutions finden Sie unter und unter finden Sie die Benutzerdokumentation. Copyright Fujitsu Technology Solutions, 2009

System Board D2786 for RX200 S5. Technical Manual

System Board D2786 for RX200 S5. Technical Manual System Board D2786 for RX200 S5 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

The activities described in these upgrade instructions may only be performed by engineers or maintenance/technical staff.

The activities described in these upgrade instructions may only be performed by engineers or maintenance/technical staff. Introduction The upgrade instructions show how to remove the standard power supply and replace it with a hotplug power supply. The following steps only apply to the PRIMERGY 400 and 00 tower servers.!

More information

System Board D2559 for TX150 S6. Technical Manual

System Board D2559 for TX150 S6. Technical Manual System Board D2559 for TX150 S6 Technical Manual Edition November 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY S40-DF Capacity Extension

PRIMERGY S40-DF Capacity Extension Server PRIMERGY S40-DF Capacity Extension Xenia Fierley Siemens Nixdorf Informationssysteme AG ICP CS PS QM 3 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 636-47896 Fax: 0 700 /

More information

This symbol is followed by supplementary information, remarks and tips.

This symbol is followed by supplementary information, remarks and tips. Introduction This Technical Manual describes the system boards of the PRIMERGY 870 server systems, which can be equipped with up to four Intel Xeon processors. You may find further information in the description

More information

System board D2004 for RX100 S3

System board D2004 for RX100 S3 PRIMERGY System board D2004 for RX100 S3 Technical manual Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49) 700

More information

System Board D2619 for RX/TX300 S5. Technical Manual

System Board D2619 for RX/TX300 S5. Technical Manual System Board D2619 for RX/TX300 S5 Technical Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

System board D2020 for Econel 200

System board D2020 for Econel 200 Produktfamilie System board D2020 for Econel 200 Technical manual Redakteur Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-??? Fax: (++49)

More information

FibreCAT TXF Backup Subsystem. Service Supplement

FibreCAT TXF Backup Subsystem. Service Supplement FibreCAT TXF Backup Subsystem Service Supplement Edition October 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

System Board D2671 for RX200 S4. Technical Manual

System Board D2671 for RX200 S4. Technical Manual System Board D2671 for RX200 S4 Technical Manual Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

System Board D3031 for PRIMERGY RX200 S6

System Board D3031 for PRIMERGY RX200 S6 Technical Manual - English System Board D3031 for PRIMERGY RX200 S6 Technical Manual Edition August 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

System Board D3034 for PRIMERGY RX100 S7

System Board D3034 for PRIMERGY RX100 S7 Technical Manual - English System Board D3034 for PRIMERGY RX100 S7 Technical Manual Edition August 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

chipdisk for RemoteView

chipdisk for RemoteView PRIMERGY chipdisk for RemoteView Xenia Fierley Siemens Nixdorf Informationssysteme AG Primergy 81730 Munich e-mail: Internet:DOCetc@mchp.siemens.de Tel.: (089) 636-47896 Fax: (++ 49) 89 6 36-4 87 17 U41102-J-Z156-1-74

More information

System Board D2799 for PRIMERGY TX200 S6

System Board D2799 for PRIMERGY TX200 S6 Technical Manual - English System Board D2799 for PRIMERGY TX200 S6 Technical Manual Edition July 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Fujitsu Siemens Computers GmbH DRV (BS2000/OSD) Version 3.1A November 2005 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Release Notice DRV V3.1A 1 General 2 1.1

More information

PRIMERGY BX630 S2 Scalable Server Blade. Options Guide

PRIMERGY BX630 S2 Scalable Server Blade. Options Guide PRIMERGY BX630 S2 Scalable Server Blade Options Guide Edition October 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

R E L E A S E N O T I C E C O S M O S T O O L S V A. (c) Fujitsu Siemens Computers GmbH 2001

R E L E A S E N O T I C E C O S M O S T O O L S V A. (c) Fujitsu Siemens Computers GmbH 2001 R E L E A S E N O T I C E C O S M O S T O O L S V 1 4. 0 A (c) Fujitsu Siemens Computers GmbH 2001 Word and Excel are registered trademarks of Microsoft Postscript is a registered trademark of Adobe Contents

More information

System Board D2870 for PRIMERGY RX600 S5

System Board D2870 for PRIMERGY RX600 S5 Technical Manual - English System Board D2870 for PRIMERGY RX600 S5 Technical Manual April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

WebTransactions V7.1. Supplement

WebTransactions V7.1. Supplement WebTransactions V7.1 Supplement Edition: December 2006 This manual describes the new functions in WebTransactions V7.1. It is intended to supplement the WebTransactions V7.0 manuals. Comments Suggestions

More information

PRIMERGY TX200 S3 Server

PRIMERGY TX200 S3 Server PRIMERGY PRIMERGY TX200 S3 Server Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700

More information

PRIMERGY BX920 S1 Server-Blade. Service Supplement

PRIMERGY BX920 S1 Server-Blade. Service Supplement PRIMERGY BX920 S1 Server-Blade Service Supplement Edition April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY RX100 S3 Server System

PRIMERGY RX100 S3 Server System PRIMERGY PRIMERGY RX100 S3 Server System Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49)

More information

Produktfamilie PRIMERGY RX200 S2

Produktfamilie PRIMERGY RX200 S2 Produktfamilie PRIMERGY RX200 S2 D1790 Setup Utility Hans-Joachim Kneba Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: 05251/8-14865 Fax: (++49)

More information

PRIMERGY SX650 Storage Blade. Operating Manual

PRIMERGY SX650 Storage Blade. Operating Manual PRIMERGY SX650 Storage Blade Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2008 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2008 All rights reserved Fujitsu Siemens Computers GmbH XHCS-SYS (BS2000/OSD) Version 2.0A June 2008 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2008 All rights reserved Release Notice XHCS-SYS V2.0A 1 General

More information

PRIMERGY Econel 200 S2 Server

PRIMERGY Econel 200 S2 Server PRIMERGY PRIMERGY Econel 200 S2 Server Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49) 700

More information

PRIMERGY Econel 100 Server System

PRIMERGY Econel 100 Server System PRIMERGY PRIMERGY Econel 100 Server System Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 89) 61 001-155 Fax: (++49)

More information

FUJITSU SIEMENS COMPUTERS. Release Notice PCMX (LINUX-S390) V6.0A. Table of Contents

FUJITSU SIEMENS COMPUTERS. Release Notice PCMX (LINUX-S390) V6.0A. Table of Contents FUJITSU SIEMENS COMPUTERS Release Notice PCMX (LINUX-S390) V6.0A Table of Contents 1 General 1.1 Documentation 2 Notes on product use 2.1 Software/hardware configuration 2.1.1 Operating system 2.2 Resource

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Fujitsu Siemens Computers GmbH SM2-TOOLS (BS2000/OSD) Version 7.5A Juli 2006 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved Release Notice SM2-TOOLS V7.5A 1 General

More information

PRIMERGY Econel 100 Server System

PRIMERGY Econel 100 Server System PRIMERGY PRIMERGY Econel 100 Server System Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 89) 61 001-155 Fax:

More information

PRIMERGY BX630 S2 Scalable Server-Blade. Service Supplement

PRIMERGY BX630 S2 Scalable Server-Blade. Service Supplement PRIMERGY BX630 S2 Scalable Server-Blade Service Supplement Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

PRIMERGY TX150 S5 Server

PRIMERGY TX150 S5 Server PRIMERGY PRIMERGY TX150 S5 Server Service Supplement Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2004 All rights reserved

Copyright (C) Fujitsu Siemens Computers GmbH 2004 All rights reserved Fujitsu Siemens Computers GmbH A I D Version 3.1 November 2004 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2004 All rights reserved Release Notice AID V3.1 1 General....................

More information

PRIMERGY BX630 Scalable Server Blade

PRIMERGY BX630 Scalable Server Blade PRIMERGY PRIMERGY BX630 Scalable Server Blade Service Supplement Redakteur Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-??? Fax:

More information

System Board D2129 for TX300 S3

System Board D2129 for TX300 S3 PRIMERGY System Board D2129 for TX300 S3 Technical Manual Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49)

More information

PRIMERGY RX200 S3 Server. Options Guide

PRIMERGY RX200 S3 Server. Options Guide PRIMERGY RX200 S3 Server Options Guide Edition August 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC) User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Last Edition August 2017 Comments Suggestions Corrections The User Documentation Department would

More information

PRIMERGY TX120 S2 Server. Service Supplement

PRIMERGY TX120 S2 Server. Service Supplement PRIMERGY TX120 S2 Server Service Supplement Edition July 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

System Board D2119 for RX300 S3

System Board D2119 for RX300 S3 PRIMERGY System Board D2119 for RX300 S3 Technical Manual Martin Jung Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-154 Fax: (++49) 700

More information

Fujitsu Siemens Computers. internet Value Edition. Version 1.0B. July Release Notice

Fujitsu Siemens Computers. internet Value Edition. Version 1.0B. July Release Notice Fujitsu Siemens Computers internet Value Edition Version 1.0B July 2002 Release Notice Copyright (C) Fujitsu Siemens Computers 2002 All rights reserved Release Notice internet Value Edition V1.0B 1 General.....................

More information

Technical Manual. Mainboard D1483. English

Technical Manual. Mainboard D1483. English answers 2 Technical Manual Mainboard D1483 English Are there...... any technical problems or other questions you need clarified? Please contact: your sales partner your sales outlet You will find further

More information

PRIMERGY TX120 S2 Server. Operating manual

PRIMERGY TX120 S2 Server. Operating manual PRIMERGY TX120 S2 Server Operating manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

STREAMER VXA /320 GB

STREAMER VXA /320 GB Operating Manual English STREAMER VXA-320 160/320 GB Are there...... any technical problems or other questions you need clarified? Please contact our Help Desk (see warranty card). The latest information

More information

Copyright (C) Fujitsu Siemens Computers GmbH 2005 *3 All rights reserved *3

Copyright (C) Fujitsu Siemens Computers GmbH 2005 *3 All rights reserved *3 Fujitsu Siemens Computers GmbH CRTE (BS2000/OSD) Version 2.4C *4 October 2005 *4 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 *3 All rights reserved *3 Release Notice CRTE V2.4C 1 General.....................

More information

PRIMERGY RX300 S2 Server System

PRIMERGY RX300 S2 Server System PRIMERGY PRIMERGY RX300 S2 Server System Monika Spanjaart Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001160 Fax: (++49) 700 / 372 00000

More information

Streamer DAT160 Half-Height 80GB/160GB, USB 2.0

Streamer DAT160 Half-Height 80GB/160GB, USB 2.0 User Guide English Streamer DAT160 Half-Height 80GB/160GB, USB 2.0 Streamer DAT160 Half-Height 80GB/160GB, USB 2.0 User Guide Edition November 2008 Comments Suggestions Corrections The User Documentation

More information

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node Standard server node for PRIMERGY CX400 M1 multi-node server system

More information

PRIMERGY BX620 S3 2-way Server Blade

PRIMERGY BX620 S3 2-way Server Blade PRIMERGY PRIMERGY BX620 S3 2-way Server Blade Options Guide Walter Dick Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 52 51)14888-12 Fax:

More information

Fujitsu PRIMERGY TX100 S2 Server

Fujitsu PRIMERGY TX100 S2 Server Datasheet Fujitsu PRIMERGY TX100 S2 Server Enter the world of servers - now with 0-Watt functionality PRIMERGY TX industry standard tower servers: efficient, rock solid, record-breaking performance. PRIMERGY

More information

Using Egenera Virtualized Boot Services

Using Egenera Virtualized Boot Services Using Egenera Virtualized Boot Services For BladeFrame BF400 S2 and BladeFrame BF200 Document Number 432-SB0045 September 2008 EVBS1.0_BF_1 Copyright Copyright 2008 Egenera, Inc. All rights reserved. This

More information

PRIMERGY RX300 S5. Service Supplement

PRIMERGY RX300 S5. Service Supplement PRIMERGY RX300 S5 Service Supplement Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY RX200 S5. Operating Manual

PRIMERGY RX200 S5. Operating Manual PRIMERGY RX200 S5 Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY RX300 S5. Operating manual

PRIMERGY RX300 S5. Operating manual PRIMERGY RX300 S5 Operating manual Edition september 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY 670 Converting Guide

PRIMERGY 670 Converting Guide PRIMERGY 670 Converting Guide Server Systems A26361-K531-Z101-1-7419 Edition March 1999 Copyright and Trademarks Intel and Pentium are registered trademarks of Intel Corporation, USA. NetWare and Novell

More information

Fujitsu PRIMERGY BX920 S1 Dual-Socket Server

Fujitsu PRIMERGY BX920 S1 Dual-Socket Server Datasheet Fujitsu PRIMERGY BX920 S1 Dual-Socket Server Blade All-around server blade packing lots of computing power in small form factor. The PRIMERGY BX Blade Servers are the ideal choice for data center

More information

PRIMERGY BX600 10GbE LAN I/O Module (PCIe)

PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Reference Guide PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Microsoft Windows Server 2003 iscsiselect Reference Guide English PRIMERGY BX600 10GbE LAN I/O Module (PCIe) Microsoft Windows Server 2003 iscsiselect

More information

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Mono-Socket Intel Xeon processor server Expandable all-round server for

More information

Modular RAID Controllers

Modular RAID Controllers User Guide - English Modular RAID Controllers "RAID 0/1 SAS based on LSI MegaRAID" "RAID 5/6 SAS based on LSI MegaRAID" "RAID Ctrl SAS 6G 0/1 (D2607)" "RAID Ctrl SAS 6G 5/6 512MB (D2616)" "PY SAS RAID

More information

Data Sheet Fujitsu PRIMERGY TX1330 M2 Server

Data Sheet Fujitsu PRIMERGY TX1330 M2 Server Data Sheet Fujitsu PRIMERGY TX1330 M2 Server Expandable all-round server for SMEs PRIMERGY TX1330 M2 The FUJITSU Server PRIMERGY TX1330 M2 is the ideal robust, expandable, and cost-efficient server for

More information

PRIMERGY TX120 Server. Operating Manual

PRIMERGY TX120 Server. Operating Manual PRIMERGY TX120 Server Operating Manual Edition July 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server

Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server Data Sheet FUJITSU Server PRIMERGY TX1330 M1 Tower Server Expandable all-round server for SMEs PRIMERGY TX1330 M1 The PRIMERGY TX1330 M1 is the

More information

Emanate Master 1.3. Readme. Edition June 2000

Emanate Master 1.3. Readme. Edition June 2000 Solaris Emanate Master 1.3 Readme Redakteur Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 636-00000 Fax: (++49) 700 / 372 00001 Bestellnummer

More information

Acer AR320 F2 Specifications

Acer AR320 F2 Specifications Acer AR320 F2 Specifications What Product overview The AR320 F2 single-socket server delivers great performance and enterprise-level scalability in a space-saving design. Proactive management utilities

More information

Acer AT310 F2 Specifications

Acer AT310 F2 Specifications Product overview The AT310 F2 delivers proactive manageability tools matched by best price-performance technology ideal for SMB and branch office business operations. This single-socket tower server also

More information

PRIMERGY RX300 S4. Options Guide

PRIMERGY RX300 S4. Options Guide PRIMERGY RX300 S4 Options Guide Edition June 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

Acer AT110 F2 Specifications

Acer AT110 F2 Specifications Product overview The AT110 F2 delivers true server-class features and expandability along with best price-performance technology to assure the success of your small-sized business. This single-socket tower

More information

Data Sheet ESPRIMO P2550. Your immediately available Office PC ESPRIMO P2550

Data Sheet ESPRIMO P2550. Your immediately available Office PC ESPRIMO P2550 Data Sheet Your immediately available Office PC Issue: October 2009 The is designed for price-conscious customers and is equipped with state-of-the-art standard Intel technology. These systems meet every

More information

PRIMERGY Econel 200 S2 Server. Operating manual

PRIMERGY Econel 200 S2 Server. Operating manual PRIMERGY Econel 200 S2 Server Operating manual Edition March 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY BX630 S2 Scalable Server Blade. Operating Manual

PRIMERGY BX630 S2 Scalable Server Blade. Operating Manual PRIMERGY BX630 S2 Scalable Server Blade Operating Manual Edition October 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

MITAC Desktop Board PD10TI Product Guide

MITAC Desktop Board PD10TI Product Guide MITAC Desktop Board PD10TI Product Guide Desktop Board Features This chapter briefly describes the main features of MITAC Desktop Board PD10TI. Table 1 summarizes the features of the Desktop Board. TABLE

More information

NEC Express5800/R120e-1M System Configuration Guide

NEC Express5800/R120e-1M System Configuration Guide NEC Express5800/R120e-1M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

Altos T310 F3 Specifications

Altos T310 F3 Specifications Product overview The Altos T310 F3 delivers proactive management tools matched by best priceperformance technology ideal for SMB and branch office operations. This singlesocket tower server features an

More information

MITAC Desktop Board PD12TI Product Guide

MITAC Desktop Board PD12TI Product Guide MITAC Desktop Board PD12TI Product Guide Desktop Board Features This chapter briefly describes the main features of MITAC Desktop Board PD12TI. Table 1 summarizes the features of the Desktop Board. Table

More information

Acer AC100 Server Specifications

Acer AC100 Server Specifications Product Overview The AC100 is a micro server in the true sense of the word. Sporting server-class specs including ECC memory, Intel Xeon processor support, and an 80 PLUS high-efficiency power supply,

More information

The MTC Autoloader FibreCAT TX24 - Use with OSD/XC at SX Servers -

The MTC Autoloader FibreCAT TX24 - Use with OSD/XC at SX Servers - The MTC Autoloader FibreCAT TX24 - Use with OSD/XC at SX Servers - Readme File Contents 1 Introduction...2 2 Characteristics...4 2.1 General Characteristics...4 2.2 Release with OSD/XC...4 2.3 Hardware,

More information

LAN Manager/X V2.2. (SINIX) SNMP Service. System Administator's Guide

LAN Manager/X V2.2. (SINIX) SNMP Service. System Administator's Guide LAN Manager/X V2.2 (SINIX) SNMP Service System Administator's Guide Is there anything you want to tell us about this manual? Please send us your comments, quoting the order number of the manual. Siemens

More information

Cisco MCS 7835-H2 Unified Communications Manager Appliance

Cisco MCS 7835-H2 Unified Communications Manager Appliance Cisco MCS 7835-H2 Unified Communications Manager Appliance Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks enabling easy collaboration

More information

Data Sheet Fujitsu PRIMERGY TX1310 M1 Server

Data Sheet Fujitsu PRIMERGY TX1310 M1 Server Data Sheet Fujitsu PRIMERGY TX1310 M1 Server Data Sheet Fujitsu PRIMERGY TX1310 M1 Server The ideal first server PRIMERGY TX1310 M1 The Fujitsu PRIMERGY TX1310 M1 is the ideal first server for small and

More information

PRIMERGY CX122 S1 Server

PRIMERGY CX122 S1 Server Operating Manual - English PRIMERGY CX122 S1 Server Operating Manual Edition November 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

SLR 50/100 GBYTE BETRIEBSANLEITUNG OPERATING MANUAL

SLR 50/100 GBYTE BETRIEBSANLEITUNG OPERATING MANUAL SLR 50/100 GBYTE BETRIEBSANLEITUNG OPERATING MANUAL Dieses Handbuch wurde auf Recycling-Papier gedruckt. This manual has been printed on recycled paper. Ce manuel est imprimé sur du papier recyclé. Este

More information

PRIMERGY TX200 S3 Server. Operating Manual

PRIMERGY TX200 S3 Server. Operating Manual PRIMERGY TX200 S3 Server Operating Manual Edition June 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Data Sheet Fujitsu PRIMERGY TX100 S3 Server

Data Sheet Fujitsu PRIMERGY TX100 S3 Server Data Sheet Fujitsu PRIMERGY TX100 S3 Server Enter the world of PRIMERGY TX servers PRIMERGY TX tower servers are ideal for use in SMEs or branch offices. They increase operational efficiency by providing

More information

PRIMERGY TX200 S4 Server. Operating manual

PRIMERGY TX200 S4 Server. Operating manual PRIMERGY TX200 S4 Server Operating manual Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

STREAMER 30/60 GBYTE BETRIEBSANLEITUNG OPERATING MANUAL

STREAMER 30/60 GBYTE BETRIEBSANLEITUNG OPERATING MANUAL STREAMER 30/60 GBYTE BETRIEBSANLEITUNG OPERATING MANUAL Dieses Handbuch wurde auf Recycling-Papier gedruckt. This manual has been printed on recycled paper. Ce manuel est imprimé sur du papier recyclé.

More information

Baseboard D3144, CPUMEMR D3145, PCIR D3146 for PRIMERGY RX900 S2

Baseboard D3144, CPUMEMR D3145, PCIR D3146 for PRIMERGY RX900 S2 Technical Manual - English Baseboard D44, MEMR D45, PCIR D46 for PRIMERGY RX9 S Technical Manual Edition May Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

PTBG965EFN LF. User Manual. English PTBG965EFN LF. Mainboard Manual

PTBG965EFN LF. User Manual. English PTBG965EFN LF. Mainboard Manual Mainboard Manual 1 Copyright Copyright 2006 FIC (First International Computer) Incorporated All rights reserved. Disclaimer: FIC Inc. shall not be liable for technical or editorial errors or omissions

More information

PRIMERGY Econel 230R S1 Server. Operating manual

PRIMERGY Econel 230R S1 Server. Operating manual PRIMERGY Econel 230R S1 Server Operating manual Edition May 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

Cisco MCS 7845-H1 Unified CallManager Appliance

Cisco MCS 7845-H1 Unified CallManager Appliance Data Sheet Cisco MCS 7845-H1 Unified CallManager Appliance THIS PRODUCT IS NO LONGER BEING SOLD AND MIGHT NOT BE SUPPORTED. READ THE END-OF-LIFE NOTICE TO LEARN ABOUT POTENTIAL REPLACEMENT PRODUCTS AND

More information

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191C2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de

More information

D2709 BIOS Setup Utility for PRIMERGY TX200 S5. Reference Manual

D2709 BIOS Setup Utility for PRIMERGY TX200 S5. Reference Manual D2709 BIOS Setup Utility for PRIMERGY TX200 S5 Reference Manual Edition May 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

Data Sheet Fujitsu PRIMERGY TX100 S2 Server

Data Sheet Fujitsu PRIMERGY TX100 S2 Server Data Sheet Fujitsu PRIMERGY TX100 S2 Server Enter the world of TX servers - now with 0-Watt functionality PRIMERGY TX tower servers are ideal for use in SMEs or branch offices. They increase operational

More information

PRIMERGY BX922 S2 Server Blade

PRIMERGY BX922 S2 Server Blade Options Guide - us PRIMERGY BX922 S2 Server Blade Options Guide Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191V2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet: http://www.ipcomm.de

More information

Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade

Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade Universal dual socket server blade with high computing and I/O performance in a small form factor The PRIMERGY BX Blade Servers are the ideal

More information

HP ProLiant MicroServer

HP ProLiant MicroServer HP ProLiant MicroServer Installation Sheet Part Number 615715-004 Panel door components Item Component 1 16 screws for HDD installation 2 4 screws for ODD installation 3 Screw driver Rear panel components

More information

PRIMERGY CX400 S1 Server Enclosure

PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual - English PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual Edition December 2012 Comments Suggestions Corrections The User Documentation Department would

More information

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Strong Performance and Cluster

More information

PRIMERGY TX150 S6 Server. Options Guide

PRIMERGY TX150 S6 Server. Options Guide PRIMERGY TX150 S6 Server Options Guide Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY SX940 S1 Storage Blade

PRIMERGY SX940 S1 Storage Blade Operating manual - English PRIMERGY SX940 S1 Storage Blade Operating manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY RX200 S4 Server. Operating manual

PRIMERGY RX200 S4 Server. Operating manual PRIMERGY RX200 S4 Server Operating manual Edition January 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information