1 PRIMERGY BX920 S1 Server-Blade Service Supplement Edition April 2010

2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by to Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2010 Fujitsu Technology Solutions GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.

3 Contents 1 Preface Documentation Overview Notational conventions Procedure Important Notes Notes on Safety Environmental protection Replacement routines Preparation Replacing processors Replacing the SAS backplane Installing a mezzanine card Population rules for mezzanine cards Installing/removing a TPM Installing a TPM Removing a TPM Diagnosis and maintenance Recovering the Server Blade BIOS Index BX920 S1 Service Supplement

4

5 1 Preface The PRIMERGY BX920 S1 Scalable Server Blade is an Intel-based server blade, that can be operated in the PRIMERGY BX900 basic unit. 1.1 Documentation Overview Concept and target groups This Service Supplement supplements the information contained in the Operating Manual, in the Options Guide and in the Technical Manual. V ATTENTION! The activities described in this manual may only be performed by specialist personnel with technical training. I The installation and removal of the hot-plug components is described in the Operating Manual supplied with the server blade. Service DVD A service DVD is available for service partners of Fujitsu Technology Solutions. This DVD contains the following manuals in PDF format: the Safety notes and other important information manual the Operating Manual for PRIMERGY BX920 S1 the Options Guide for PRIMERGY BX920 S1 the Technical Manual for the system board D2860 BX920 S1 Service Supplement 5

6 Documentation Overview Preface Information/Activity Manual Features and technical data of the server blade Operating Manual Installation and initial operation, such as: Operation and Display units Configuring the server blades Installing the server blades in the basic unit BIOS setup Troubleshooting Installing/removing hot-plug components: Hard disk modules Extensions and conversions Installing memory modules Adding processors Replacement routines Exchanging the processor Exchanging SAS Backplane Installing Card Exchanging TPM Options Guide Service Supplement Diagnostics BIOS recovery Information about the server blade Features of the server blades Board layout Jumper settings LED displays Replacing the battery Spare parts Detailed safety notes Technical Manual Illustrated Spares Catalogue Safety notes Table 1: Overview of the documentation BX920 S1 Server Blade 6 Service Supplement BX920 S1

7 Preface Notational conventions 1.2 Notational conventions The following notational conventions are used in this manual: Text in italics Quotation marks V CAUTION! I indicates commands, menu items or software programs. indicate names of chapters and terms that are being emphasized. describes activities that must be performed in the order shown. pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. indicates additional information, notes and tips. Table 2: Notational conventions BX920 S1 Service Supplement 7

8

9 2 Procedure V ATTENTION! The activities described in this manual should only be performed by engineers, service personnel or technical specialists. First of all please familiarize yourself with the safety instructions in the chapter Important Notes on page 11 ff. Make sure that all the manuals you need (see service DVD) are available, printing out the PDF files if necessary. You will definitely need the operating manuals of the server blade and of your BX900 basic unit. Shut down the server blade correctly, switch it off and remove it from the basic unit as described in the chapter Replacement routines on page 17 ff. Replace the defective component as described in the relevant chapter. Close the server blade. Start the server blade. 1 If necessary, configure the operating system as required. 1 1 See Operating Manual. BX920 S1 Service Supplement 9

10

11 3 Important Notes This chapter provides safety instructions which you must observe when handling your system. 3.1 Notes on Safety I The following safety instructions can also be found in the manual entitled Safety. This device complies with the relevant safety regulations for IT equipment, including electronic office machines for use in an office environment. If you have any questions, contact your sales outlet or the Fujitsu Technology Solutions customer service center. V ATTENTION! The activities described in this manual should only be performed by engineers, service personnel or technical specialists. Equipment repairs should only be performed by qualified staff! Any failure to observe the guidelines in this manual could endanger the user (through electric shock, fire hazards) or damage the equipment. Please note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability. Before setting up V ATTENTION! During installation and before operating the device, observe the instructions on environmental conditions for your device (see Operating Manual). If the device is brought in from a cold environment, condensation may form both inside and on the outside of the machine. Before operating the device, wait until it is absolutely dry and has reached approximately the same temperature as the installation site. Any failure to observe the guidelines in this manual could damage the equipment. BX920 S1 Service Supplement 11

12 Notes on Safety Important Notes V ATTENTION! Transport the device only in its original packaging or in packaging which protects it from knocks and jolts. Installation and operation V ATTENTION! Read the notes on installation and operation in the Operating Manual of the PRIMERGY BX900 basic unit. When installing the server blade in the basic unit, beware of the energy hazard at the midplane conctacts. A short-circuit on these contacts may damage the system. Data cables must be adequately shielded to avoid interference. For the LAN wiring, the requirements according to standards EN and EN /2 apply. The minimum requirement is the use of a protected LAN line of category 5 for 10/100 Mbps Ethernet, and/or of category 5e for Gigabit Ethernet. The requirements of the specification ISO/IEC must also be taken into account. Route the cables in such a way that they do not form a potential hazard (tripping) and cannot be damaged. When connecting the device, refer to the relevant notes in the Operating Manual. Do not connect or disconnect any data transmission cables during a thunderstorm (lightning hazard). Be careful to ensure that no objects (e.g. jewelry, paper clips etc.) or liquids get inside the device (electric shock, short circuit). In emergencies (e.g. damaged casing, elements, or cables, penetration of liquids or foreign bodies), switch off the device immediately, unplug it from the grounded power outlet, and contact your customer service centre. V ATTENTION! Proper operation of the device (in accordance with IEC60950/EN 60950) is only ensured if the casing is completely assembled and the rear covers for the installation openings are in place (electric shock, cooling, fire protection, interference suppression). 12 Service Supplement BX920 S1

13 Important Notes Notes on Safety Install only system extensions that satisfy the requirements and rules governing safety, electromagnetic compatibility, and telecommunications terminal equipment. If you install other extensions, you may damage the system or violate these safety regulations. Information on which system extensions are suitable can be obtained from the customer service center or your sales outlet. The components marked with a warning label (e.g. lightning symbol) may only be opened, removed, or exchanged by authorized, qualified personnel, with the exception of the hot-plug/hot-swap components. If you cause a defect on the device by installing or exchanging system extensions, the warranty will be invalidated. You may only set the resolutions and refresh rates specified in the operating manual for your monitor. Otherwise, you may damage the monitor. If you are in any doubt, contact your sales outlet or customer service center. Batteries V ATTENTION! Incorrect replacement of batteries can lead to risk of explosion. The batteries must be replaced with an identical battery or with a battery type recommended by the manufacturer. see Technical Manual System Board D2860 for BX920. Do not throw batteries into the trash can. Please dispose of them in accordance with local regulations for special refuse. V ATTENTION! Replace the lithium battery on the system board in accordance with the instructions in the Technical Manual for the system board. All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant: Cd Cadmium Hg Mercury Pb Lead BX920 S1 Service Supplement 13

14 Notes on Safety Important Notes Modules with electrostatic-sensitive components: Components that might be damaged by electrostatic discharge (ESD) are marked with the following label: Figure 1: ESD labe When you handle components fitted with ESDs, you must observe the following points under all circumstances: Remove the power plug from the power socket before inserting or removing components containing ESDs. You must always discharge yourself of static charges (e.g. by touching a grounded object) before working. The equipment and tools you use must be free of static charges. Only touch the components at the positions highlighted in green (Touchpoints). Do not touch any exposed pins or conductors on a component. Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components. Place all components on a static-safe base. I You will find a detailed description for handling ESD components in the relevant European or international standards (DIN EN , ANSI/ESD S20.20). 14 Service Supplement BX920 S1

15 Important Notes Environmental protection 3.2 Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu Siemens Computers standard for environmentally friendly product design and development. This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account. This saves resources and thus reduces the harm done to the environment. Energy-saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work. Packaging information Do not throw away the packaging. You may need it later for transporting the system. If possible, the equipment should only be transported in its original packaging. Information on handling consumables Please dispose of printer consumables and batteries in accordance with the applicable national regulations. In accordance with EU directives, batteries must not be disposed of with unsorted domestic waste. They can be returned free of charge to the manufacturer, dealer or an authorized agent for recycling or disposal. All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants: Cd Cadmium Hg Mercury Pb Lead Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible, since this makes it difficult to recycle them. BX920 S1 Service Supplement 15

16 Environmental protection Important Notes Returns, recycling and disposal The device must not be disposed of with domestic waste. This device is labeled in compliance with European directive 2002/96/EC on waste electrical and electronic equipment (WEEE). This directive sets the framework for returning and recycling used equipment and is valid across the EU. When returning your used device, please use the return and collection systems available to you. Further information can be found at Details regarding the return and recycling of devices and consumables within Europe can also be found in the Returning used devices manual, via your local Fujitsu Technology Solutions branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D Paderborn Tel Fax Service Supplement BX920 S1

17 4 Replacement routines V CAUTION! It is essential to observe the safety instructions in the chapter "Important Notes" on page 11ff when handling systems and boards. 4.1 Preparation If you want to replace components that are not hot-pluggable, you must remove the server blade from the system unit and open it. Exit all applications and shut down the server blade correctly. Press the On/Off button on the server blade control panel. Removing the Server Blade from the system unit Undo the locking mechanism of the release lever (1). Push the release lever down (2). 1 2 Figure 2: Unlocking the server blade BX920 S1 Service Supplement 17

18 Preparation Replacement routines Pull the server blade out of the system unit. Figure 3: Removing the server blade from the system unit 18 Service Supplement BX920 S1

19 Replacement routines Preparation Removing the housing cover 2 1 Figure 4: Removing the housing cover Press the touch point down (1). Slide the housing cover as far as possible in the direction of the arrow (2). Take off the housing cover. The server blade components are now freely accessible. BX920 S1 Service Supplement 19

20 Replacing processors Replacement routines 4.2 Replacing processors One or two processors can be installed in the server blade. V CAUTION! Only use processors of the same type in a server blade. All processors must have the same frequency and cache size. For multi-processor mode use a suitable multi-processor operating system. Never touch the processor core. Be careful, that the thermal paste ist not damaged. Never install a processor without a heat sink as otherwise the processor may overheat, causing the processor and system board to fail. Requirements The server blade has been removed. The server blade cover has been removed. 20 Service Supplement BX920 S1

21 Replacement routines Replacing processors Removing the heat sink Figure 5: Removing the heat sink Loosen the four screws that fasten the processor heat sink to the processor, and remove the heat sink. Removing the processor CPU 1 CPU 2 Figure 6: Position of the processors The following section illustrates how to remove CPU 1. BX920 S1 Service Supplement 21

22 Replacing processors Replacement routines Push the locking lever of the processor socket down and to the side from its locked position, and then swivel it up. Figure 7: Unlocking the locking lever Open the locking frame of the processor socket. V CAUTION! Handle the locking frame carefully. The frame may scratch the system board when positioned vertically. 22 Service Supplement BX920 S1

23 Replacement routines Replacing processors Remove the processor from the processor socket. Figure 8: Removing the processor Place the new processor on the socket. Figure 9: Inserting the processor I Make sure that the recesses on the processor are aligned with the corresponding markings on the socket. BX920 S1 Service Supplement 23

24 Replacing processors Replacement routines Figure 10: Locking the processor holder Close the locking frame of the processor and swivel the locking lever of the socket down. Lock the locking lever under the bracket (arrow) on the processor socket. Installing the heat sink I Note that different heat sink models must be installed for CPU 1 and CPU 2. Figure 11: Different heat sinks for CPU 1 and 2 The figure above shows the installation positions of the different-sized heat sinks. The following section illustrates how to mount the heat sink for CPU 1. Please observe the following before installing a used heat sink: 24 Service Supplement BX920 S1

25 Replacement routines Replacing processors V CAUTION! Before installing the heat sink, check that the thermal paste has not been damaged. If the thermal paste has been damaged, you must carry out the following before reinstalling the heat sink: Remove the residual thermal paste from the underside of the heat sink and clean the upper side of the processor. To do this, use a lint-free cloth soaked in isopropyl alcohol (e.g. CleanTex TexPad 801, available from specialist shops). Apply a new coat of thermal paste to the underside of the heat sink. Place the heat sink on the processor and fasten it by tightening the four pre-mounted screws (combi-hexagon with torque value of 0.6 Nm) in a crossover pattern. Figure 12: Screws for fastening the heat sink BX920 S1 Service Supplement 25

26 Replacing processors Replacement routines V CAUTION! Take care to place the heat sink on the system board very precisely. Careless handling may damage conductors and render the system board useless. Figure 13: Incorrect positioning of the heat sink 26 Service Supplement BX920 S1

27 Replacement routines Replacing the SAS backplane 4.3 Replacing the SAS backplane The server blade has two SAS backplanes to connect SAS/SATA hard disk modules to the system board. Requirements The server blade is removed from the system unit. The cover of the server blade is removed. The corresponding hard disk module is removed. The figure below shows the position of the SAS backplanes: "0" indicates the backplane of hard disk drive 0, "1" indicates the backplane of hard disk drive 1. Bild 14: Mounting postions of the SAS backplanes BX920 S1 Service Supplement 27

28 Replacing the SAS backplane Replacement routines Bild 15: Removing the backplane Lift the SAS backplane up and remove it from the fixing brackets (1). To insert a SAS backplane, perform the procedure in reverse. 28 Service Supplement BX920 S1

29 Replacement routines Installing a mezzanine card 4.4 Installing a mezzanine card One or two mezzanine cards can be installed in a PRIMERGY BX920 S1 Server-Blade. Additional Fibre Channel, Ethernet and/or Infiniband I/O channels can be set up using these cards. All mezzanine cards have the same form factor. Figure 16: card The mezzanine cards are fastened on a special carrier and then connected together with the carrier to the system board. The figure below shows an unpopulated carrier for mezzanine cards. BX920 S1 Service Supplement 29

30 Installing a mezzanine card Replacement routines 1 2 Figure 17: Carrier for mezzanine cards I Note the numbering of the slots Population rules for mezzanine cards card 1 card 2 Figure 18: Slot numbering for mezzanine cards The slots of the mezzanine cards in the server blade are connected to certain connection blade slots on the back of the system unit. You therefore need to observe how the connection blade slots are populated on the back of the system unit when installing mezzanine cards. 30 Service Supplement BX920 S1

31 Replacement routines Installing a mezzanine card Fabric 1 Fabric 2 Fabric 3 Fabric 4 CB1 CB3 CB5 CB7 CB2 CB4 CB6 CB8 Figure 19: Slot numbering for connection blades The figure below shows the connections of the connection blade slots to the slots for mezzanine cards. Fabric 1 Fabric 2 Fabric 3 Fabric 4 System unit Connection blade slots CB1: CB2: 1 Gb Ethernet 1 Gb Ethernet CB3: CB5: CB7: 1 Gb Ethernet or 10 Gb Ethernet or Fibre Channel CB4: or Infiniband (CB3/4) 1 Gb Ethernet or 10 Gb Ethernet or Fibre Channel CB6: or Infiniband (CB5/6) 1 Gb Ethernet CB8: or Infiniband (CB7/8) 1 Gb Ethernet or 10 Gb Ethernet or Fibre Channel 1 Gb Ethernet or 10 Gb Ethernet or Fibre Channel 1 Gb Ethernet Server Blade Onboard LAN controller card 1 card 2 card --- Eth 1 Gb 4 port or Eth 10 Gb 2 port or FC 8 Gb 2 port or IB 40 Gb 2 port Eth 1 Gb 4 port or Eth 10 Gb 2 port or FC 8 Gb 2 port or IB 40 Gb 2 port Eth 1 Gb 4 port or IB 40 Gb 2 port BX920 S1 Service Supplement 31

32 Installing a mezzanine card Replacement routines As a result, the rules for populating the mezzanine card slots are as follows: If a 1 Gb Ethernet mezzanine card is installed in slot 1, at least one 1 Gb Ethernet connection blade must be installed in fabric 2. Fabric 1 Fabric 2 Fabric 3 Fabric 4 System unit Connection blade slots CB1: CB2: 1 Gb Ethernet 1 Gb Ethernet CB3: CB5: CB7: 1 Gb Ethernet CB4: CB6: CB8: 1 Gb Ethernet Server Blade Onboard LAN controller card 1 card 2 card --- Eth 1 Gb 4 port If a 10 Gb Ethernet mezzanine card is installed in slot 1, at least one 10 Gb Ethernet connection blade must be installed in fabric 2. Fabric 1 Fabric 2 Fabric 3 Fabric 4 System unit Connection blade slots CB1: CB2: 1 Gb Ethernet 1 Gb Ethernet CB3: CB5: CB7: 10 Gb Ethernet CB4: CB6: CB8: 10 Gb Ethernet Server Blade Onboard LAN controller card 1 card 2 card --- Eth 10 Gb 2 port 32 Service Supplement BX920 S1

33 Replacement routines Installing a mezzanine card If an 8 Gb Fibre Channel mezzanine card is installed in slot 1, at least one Fibre Channel connection blade must be installed in fabric 2. Fabric 1 Fabric 2 Fabric 3 Fabric 4 System unit Connection blade slots CB1: CB2: 1 Gb Ethernet 1 Gb Ethernet CB3: CB5: CB7: Fibre Channel CB4: CB6: CB8: Fibre Channel Server Blade Onboard LAN controller card 1 card 2 card --- FC 8 Gb 2 port If an 40 Gb Infiniband mezzanine card is installed in slot 1, an Infiniband connection blade must be installed in fabric 2. I In this case only one of two ports of the mezzanine card will be utilized and connected to the connection blade in fabric 2. Fabric 1 System unit Connection blade slots CB1: CB2: 1 Gb Ethernet 1 Gb Ethernet Server Blade Onboard LAN controller card --- Fabric 2 Fabric 3 Fabric 4 CB5: CB7: Infiniband (CB3/4) CB6: CB8: card 1 card 2 IB 40 Gb 2 port BX920 S1 Service Supplement 33

34 Installing a mezzanine card Replacement routines If a 1 Gb Ethernet mezzanine card is installed in slot 2, at least one 1 Gb Ethernet connection blade must be installed in fabric 3 or in fabric 4. Fabric 1 Fabric 2 Fabric 3 Fabric 4 System unit Connection blade slots CB1: CB2: 1 Gb Ethernet 1 Gb Ethernet CB3: CB5: CB7: 1 Gb Ethernet 1 Gb Ethernet CB4: CB6: CB8: 1 Gb Ethernet 1 Gb Ethernet Server Blade Onboard LAN controller card 1 card 2 card --- Eth 1 Gb 4 port If a 10 Gb Ethernet mezzanine card is installed in slot 2, at least one 10 Gb Ethernet connection blade must be installed in fabric 3. Fabric 1 Fabric 2 Fabric 3 Fabric 4 System unit Connection blade slots CB1: CB2: 1 Gb Ethernet 1 Gb Ethernet CB3: CB5: CB7: 10 Gb Ethernet CB4: CB6: CB8: 10 Gb Ethernet Server Blade Onboard LAN controller card 1 card 2 card --- Eth 10 Gb 2 port 34 Service Supplement BX920 S1

35 Replacement routines Installing a mezzanine card If an 8 Gb Fibre Channel mezzanine card is installed in slot 2, at least one Fibre Channel connection blade must be installed in fabric 3. Fabric 1 Fabric 2 Fabric 3 Fabric 4 System unit Connection blade slots CB1: CB2: 1 Gb Ethernet 1 Gb Ethernet CB3: CB5: CB7: Fibre Channel CB4: CB6: CB8: Fibre Channel Server Blade Onboard LAN controller card 1 card 2 card --- FC 8 Gb 2 port If an 40 Gb Infiniband mezzanine card is installed in slot 2, Infiniband connection blades should be installed in fabrics 3 and 4. I In this case the dual ports of the mezzanine card will be available and one of two ports will be connected to connection blade in fabric 3, the other one will be connected to connection blade in fabric 4. Fabric 1 Fabric 2 System unit Connection blade slots CB1: CB2: 1 Gb Ethernet 1 Gb Ethernet Server Blade Onboard LAN controller CB3: CB4: card 1 card --- Fabric 3 Fabric 4 Infiniband (CB5/6) Infiniband (CB7/8) card 2 IB 40 Gb 2 port BX920 S1 Service Supplement 35

36 Installing a mezzanine card Replacement routines Installing mezzanine cards The following section illustrates how to install a mezzanine card in slot 2. Figure 20: Detaching the carrier Remove the carrier from the server blade housing by lifting it up, keeping it as horizontal as possible. 36 Service Supplement BX920 S1

37 Replacement routines Installing a mezzanine card 1 2 Figure 21: Removing the riser card Remove the riser card from the holder at the slot of mezzanine card Figure 22: Inserting the mezzanine card 2 BX920 S1 Service Supplement 37

38 Installing a mezzanine card Replacement routines Place the mezzanine card on the two guide pins (1) at the slot of mezzanine card 2 and press the mezzanine card down so that it clicks into place between the two clips (2). Figure 23: Reconnecting the riser card Connect the riser card to the mezzanine card connector. Make sure that the green clips click into place. I card 1 is fastened to the carrier with the component side facing downward. card 1 is otherwise installed in the same way as mezzanine card 2. Figure 24: Installing the carrier 38 Service Supplement BX920 S1

39 Replacement routines Installing a mezzanine card Install the carrier with the mezzanine cards in the server blade housing. As you do this, the riser cards are inserted in the corresponding system board slots. Make sure that the coding on the carrier matches that on the server blade housing. BX920 S1 Service Supplement 39

40 Installing/removing a TPM Replacement routines 4.5 Installing/removing a TPM TPMs (Trusted Platform Module) can be installed in the server blade Installing a TPM Figure 25: Scope of delivery of TPM The figure above shows the contents of the TPM installation kit. 1 TPM (Trusted Platform Module) 2 TPM spacer 3 Special screw for the TPM module 4 Insert bit for special screw 40 Service Supplement BX920 S1

41 Replacement routines Installing/removing a TPM Figure 26: TPM spacer Insert the spacer in the recess next to the multi-pin connector for the TPM. The plastic spacer must audibly click into place. Figure 27: Trusted Platform Module Connect the TPM to the multi-pin connector. BX920 S1 Service Supplement 41

42 Installing/removing a TPM Replacement routines Figure 28: Special screw for the TPM module Fasten the TPM using the special screw. Use a bit screwdriver and the special insert bit (torque value 0.6 Nm). I CAUTION! Do not fasten the screw too tightly. You must be able to remove the screw again Removing a TPM To remove a TPM, you must remove the system board. Make sure that the mezzanine card carrier and the HDD modules have been removed, see figure 17 and section "Installing/removing the HDD module" in the operating manual. 42 Service Supplement BX920 S1

43 Replacement routines Installing/removing a TPM Remove the screw (1). Slide the system board as far as it will go in the direction of the arrow (2). Lift the system board up to remove it. Remove the TPM screw from the underside of the system board using a fine slotted screwdriver (watchmaker screwdriver). The arrow indicates the slot on the bottom of the TPM screw. Disconnect the TPM from the slot. Reinstall the system board. The procedure for installing the system board is the same as for removing it, except in reverse order. BX920 S1 Service Supplement 43

44 Installing/removing a TPM Replacement routines 44 Service Supplement BX920 S1

45 5 Diagnosis and maintenance 5.1 Recovering the Server Blade BIOS This section describes the procedure you can use to recover a server blade BIOS in the event of an error. V CAUTION! This procedure is only intended for use in the event of an error. Requirements The system unit is connected to the power supply system. The server blade is switched off. An external USB memory stick is available. Creating a BIOS Flash USB memory stick Expand the BIOS update ZIP archive file on the hard disk of a PC. I You will find the data for creating the BIOS Flash USB memory stick in the software pool at Insert an empty USB memory stick into an USB host connector of the PC. Copy the content of the ZIP archive file to the USB memory stick to create a BIOS Flash USB memory stick. First option: Recovering the server blade BIOS via management blade Log in to the management blade GUI. Select the server blade for BIOS recovery. Click on Configuration Click on Boot Options. BX920 S1 Service Supplement 45

46 Recovering the Server Blade BIOS Diagnosis and maintenance Bild 29: Boot Options menu Select BIOS Recovery Flash Bit Enabled. Connect the monitor, keyboard, mouse and USB memory stick to the port on the front of the server blade using the Y cable, see the Operating Manual. Switch on the server blade, see the Operating Manual. After a short beep, the BIOS upload is executed. The status of the Flash operation is displayed on screen. Once the Flash operation is complete, information on how to proceed is displayed: Switch off the server blade. Remove the Y cable. Bild 30: Boot Options menu Deselect BIOS Recovery Flash Bit Enabled in the management blade Boot Options menu. Switch the server blade on. You can now put the server blade back into operation. Second option: Recovering the server blade BIOS via USB memory stick Remove the server blade from the blade server chassis and open it as described in section "Removing the housing cover" on page Service Supplement BX920 S1

47 Diagnosis and maintenance Recovering the Server Blade BIOS Turn switch 3 of the user DIP switch bank (A) to ON. A CPU 2 CPU 1 Bild 31: Position des DIP-Schalters (A) auf dem System Board Close the server blade cover and reinstall the server blade in the blade server chassis. Connect the monitor, keyboard, mouse and USB memory stick to the port on the front of the server blade using the Y cable, see the Operating Manual. Switch on the server blade, see the Operating Manual. After a short beep, the BIOS upload is executed. The status of the Flash operation is displayed on screen. Once the Flash operation is complete, information on how to proceed is displayed: Switch off the server blade. Remove the Y cable. Remove the server blade again and open it. Turn switch 3 of the user DIP switch bank to OFF again. Close the server blade and reinstall it. You can now put the server blade back into operation. BX920 S1 Service Supplement 47

48 Recovering the Server Blade BIOS Diagnosis and maintenance 48 Service Supplement BX920 S1

49 Index B battery 13 BIOS recovering 45 update 46, 47 C cadmium 13 connection blade 30 slots 31 consumables 15 CPU 21 D DIP-Schalter 47 documentation 5 E electrostatic discharge (ESD) 14 electrostatic discharge (ESD), components might be damaged 14 environmental protection 15 F form factor 29 H heat sink 20 L labels 15 lead 13 lithium battery 13 N notational conventions 7 notes on safety 11 P packaging 15 processors 21 installing/removing 20 R recovery BIOS 45 recycling, of devices 16 return, of devices 16 S SAS backplane 28 saving energy 15 server blade opening 19 removing from system unit 17 T target group 5 thermal paste 25 touch point 14, 19 Y Y cable 46, 47 M meaning of the symbols 7 mercury 13 mezzanine card 29 form factor 29 multiprocessor mode 20 BX920 S1 Service Supplement 49

50

PRIMERGY TX120 S2 Server. Service Supplement

PRIMERGY TX120 S2 Server. Service Supplement PRIMERGY TX120 S2 Server Service Supplement Edition July 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY SX650 Storage Blade. Operating Manual

PRIMERGY SX650 Storage Blade. Operating Manual PRIMERGY SX650 Storage Blade Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

PRIMERGY BX620 S6 Server Blade

PRIMERGY BX620 S6 Server Blade Service Supplement - English PRIMERGY BX620 S6 Server Blade Service Supplement September 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY BX922 S2 Server Blade

PRIMERGY BX922 S2 Server Blade Options Guide - us PRIMERGY BX922 S2 Server Blade Options Guide Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

PRIMERGY BX620 S3 2-way Server Blade

PRIMERGY BX620 S3 2-way Server Blade PRIMERGY PRIMERGY BX620 S3 2-way Server Blade Options Guide Walter Dick Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (0 52 51)14888-12 Fax:

More information

PRIMERGY RX300 S2 Server System

PRIMERGY RX300 S2 Server System PRIMERGY PRIMERGY RX300 S2 Server System Monika Spanjaart Fujitsu Siemens Computers GmbH München 81730 Munich e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001160 Fax: (++49) 700 / 372 00000

More information

PRIMERGY RX300 S4. Options Guide

PRIMERGY RX300 S4. Options Guide PRIMERGY RX300 S4 Options Guide Edition June 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

PRIMERGY RX300 S5. Service Supplement

PRIMERGY RX300 S5. Service Supplement PRIMERGY RX300 S5 Service Supplement Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY RX100 S6 Server. Service Supplement

PRIMERGY RX100 S6 Server. Service Supplement PRIMERGY RX100 S6 Server Service Supplement Edition january 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

PRIMERGY SX940 S1 Storage Blade

PRIMERGY SX940 S1 Storage Blade Operating manual - English PRIMERGY SX940 S1 Storage Blade Operating manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY RX600 S5 Server

PRIMERGY RX600 S5 Server Service Supplement - English PRIMERGY RX600 S5 Server Service Supplement June 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

PRIMERGY RX600 S4 Server. Service Supplement

PRIMERGY RX600 S4 Server. Service Supplement PRIMERGY RX600 S4 Server Service Supplement Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

PRIMERGY TX300 S6 Server

PRIMERGY TX300 S6 Server Service Supplement - English PRIMERGY TX300 S6 Server Service Supplement Edition March 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY CX400 S1 Server Enclosure

PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual - English PRIMERGY CX400 S1 Server Enclosure Upgrade and Maintenance Manual Edition December 2012 Comments Suggestions Corrections The User Documentation Department would

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x Last Updated: December 4, 2014 Use these instructions to replace the RAID battery backup unit (BBU)

More information

PRIMERGY TX300 S3 Server

PRIMERGY TX300 S3 Server PRIMERGY PRIMERGY TX300 S3 Server Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: (++49) 700 /

More information

PRIMERGY SX910 S1 Storage Blade

PRIMERGY SX910 S1 Storage Blade Operating Manual - English PRIMERGY SX910 S1 Storage Blade Operating Manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY TX150 S6 Server. Options Guide

PRIMERGY TX150 S6 Server. Options Guide PRIMERGY TX150 S6 Server Options Guide Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC) User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Last Edition August 2017 Comments Suggestions Corrections The User Documentation Department would

More information

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191V2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet: http://www.ipcomm.de

More information

PRIMERGY TX120 S2 Server. Operating manual

PRIMERGY TX120 S2 Server. Operating manual PRIMERGY TX120 S2 Server Operating manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY BX630 S2 Scalable Server-Blade. Service Supplement

PRIMERGY BX630 S2 Scalable Server-Blade. Service Supplement PRIMERGY BX630 S2 Scalable Server-Blade Service Supplement Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

FUJITSU Server PRIMERGY RX1330 M2

FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M2 Upgrade and Maintenance Manual December 2015 Comments Suggestions Corrections The User Documentation Department would like to

More information

Modular RAID Controllers

Modular RAID Controllers User Guide - English Modular RAID Controllers "RAID 0/1 SAS based on LSI MegaRAID" "RAID 5/6 SAS based on LSI MegaRAID" "RAID Ctrl SAS 6G 0/1 (D2607)" "RAID Ctrl SAS 6G 5/6 512MB (D2616)" "PY SAS RAID

More information

FibreCAT TXF Backup Subsystem. Service Supplement

FibreCAT TXF Backup Subsystem. Service Supplement FibreCAT TXF Backup Subsystem Service Supplement Edition October 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

Installation manual plugs and connectors with screw connection (16/32 A)

Installation manual plugs and connectors with screw connection (16/32 A) EN Installation manual plugs and connectors with screw connection (16/32 60003213 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3

More information

Dell Inspiron XPS and Inspiron 9100 Service Manual

Dell Inspiron XPS and Inspiron 9100 Service Manual Dell Inspiron XPS and Inspiron 9100 Service Manual Dell Inspiron XPS and Inspiron 9100 Service Manual Before You Begin Memory Module, Mini PCI Card, and Devices System Components Subwoofer Bluetooth Card

More information

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191C2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de

More information

B63/ NS MS. EtherNet/IP LINK

B63/ NS MS. EtherNet/IP LINK 3 609 929 B63/ IMenip 2008-09 NS MS EtherNet/IP LINK 3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 15/76 Table of Contents About this document................. 16 General safety instructions............

More information

PRIMERGY BX924 S2 Server Blade

PRIMERGY BX924 S2 Server Blade Operating Manual - English PRIMERGY BX924 S2 Server Blade Operating Manual Edition May 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

FUJITSU Server PRIMERGY RX100 S8

FUJITSU Server PRIMERGY RX100 S8 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX100 S8 Upgrade and Maintenance Manual April 2015 Comments Suggestions Corrections The User Documentation Department would like to know

More information

System Board D2870 for PRIMERGY RX600 S5

System Board D2870 for PRIMERGY RX600 S5 Technical Manual - English System Board D2870 for PRIMERGY RX600 S5 Technical Manual April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY BX630 Scalable Server Blade

PRIMERGY BX630 Scalable Server Blade PRIMERGY PRIMERGY BX630 Scalable Server Blade Service Supplement Redakteur Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-??? Fax:

More information

Inspiron 22. Service Manual Series. Regulatory Model: W17B Regulatory Type: W17B001

Inspiron 22. Service Manual Series. Regulatory Model: W17B Regulatory Type: W17B001 Inspiron 22 3000 Series Service Manual Regulatory Model: W17B Regulatory Type: W17B001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

D610H, D610H MKII, D610S, D610T dimmer pack. user manual D610H, D610H MKII, D610S, D610T dimmer pack user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

4.1 General. 4 Replacement Procedures

4.1 General. 4 Replacement Procedures 4.1 General This chapter explains how to disassemble the computer and replace Field Replaceable Units (FRUs). It may not be necessary to remove all the FRUs in order to replace one. The chart below is

More information

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211 Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211 Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215,

More information

XPS 15 2-in-1. Service Manual. Computer Model: XPS Regulatory Model: P73F Regulatory Type: P73F001

XPS 15 2-in-1. Service Manual. Computer Model: XPS Regulatory Model: P73F Regulatory Type: P73F001 XPS 15 2-in-1 Service Manual Computer Model: XPS 15-9575 Regulatory Model: P73F Regulatory Type: P73F001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better

More information

PRIMERGY BX920 S2 Server Blade

PRIMERGY BX920 S2 Server Blade Operating Manual - English PRIMERGY BX920 S2 Server Blade Operating Manual Edition March 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

PRIMERGY CX122 S1 Server

PRIMERGY CX122 S1 Server Operating Manual - English PRIMERGY CX122 S1 Server Operating Manual Edition November 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.

More information

PRIMERGY Econel 200 S2 Server. Operating manual

PRIMERGY Econel 200 S2 Server. Operating manual PRIMERGY Econel 200 S2 Server Operating manual Edition March 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

Rocsecure NE52 NAS System

Rocsecure NE52 NAS System Rocsecure NE52 NAS System Revision 1.0 Table of Contents Preface... 3 Before You Begin... 4 Safety Guidelines... 4 Packaging, Shipment and Delivery... 4 Chapter 1 Introduction... 5 1.1 Key Features...

More information

PRIMERGY S40-DF Capacity Extension

PRIMERGY S40-DF Capacity Extension Server PRIMERGY S40-DF Capacity Extension Xenia Fierley Siemens Nixdorf Informationssysteme AG ICP CS PS QM 3 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 636-47896 Fax: 0 700 /

More information

PRIMERGY RX600 S3 SAS Server

PRIMERGY RX600 S3 SAS Server PRIMERGY PRIMERGY RX600 S3 SAS Server Options Guide Joachim Pichol Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (05251) 148 88-18 Fax: 0 700

More information

FUJITSU Server PRIMERGY RX1330 M3

FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M3 Upgrade and Maintenance Manual April 2017 Comments Suggestions Corrections The User Documentation Department would like to know

More information

PRIMERGY Econel 40. Operating manual. Introduction. Important notes. Preparing for use. Operation. Troubleshooting and tips.

PRIMERGY Econel 40. Operating manual. Introduction. Important notes. Preparing for use. Operation. Troubleshooting and tips. Introduction Important notes PRIMERGY Econel 40 Preparing for use Operation Operating manual Troubleshooting and tips System expansions Technical data Index April 2004 edition Microsoft, MS, MS-DOS, Windows,

More information

PRIMERGY TX600 S3 Server

PRIMERGY TX600 S3 Server PRIMERGY PRIMERGY TX600 S3 Server Options Guide Joachim Pichol Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (05251) 14888-18 Fax: (++49) 700

More information

DS-1H05 Ethernet-over-Coax Extender. User Manual

DS-1H05 Ethernet-over-Coax Extender. User Manual DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,

More information

Handbuch. DAVIDE Mini PC GRAFENTHAL

Handbuch. DAVIDE Mini PC GRAFENTHAL Handbuch GRAFENTHAL DAVIDE Mini PC GRAFENTHAL GmbH von-monschaw-straße 3 47574 Goch info@grafenthal.de www.grafenthal.de Copyright 2017 GRAFENTHAL GmbH, Alle Rechte vorbehalten. GRAFENTHAL ist eine eingetragene

More information

Dell Inspiron N5110 Service Manual

Dell Inspiron N5110 Service Manual Dell Inspiron N5110 Service Manual Regulatory model: P17F Regulatory type: P17F001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

PRIMERGY TX300 S4 Server. Options Guide

PRIMERGY TX300 S4 Server. Options Guide PRIMERGY TX300 S4 Server Options Guide Edition December 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

Oracle <Insert Picture Here>

Oracle <Insert Picture Here> Slide 1 Oracle Slide 2 WZT-6509 version B Sun Fire Nehalem and Westmere Rack-Mount Server Installation and Replacement Welcome to the installation and replacement

More information

PRIMERGY TX120 Server. Operating Manual

PRIMERGY TX120 Server. Operating Manual PRIMERGY TX120 Server Operating Manual Edition July 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY RX600 S3 Server

PRIMERGY RX600 S3 Server PRIMERGY PRIMERGY RX600 S3 Server Options Guide Joachim Pichol Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.: (05251) 148 88-18 Fax: 0 700 / 372

More information

PRIMERGY BX600 S2 Basic Unit. Operating Manual

PRIMERGY BX600 S2 Basic Unit. Operating Manual PRIMERGY BX600 S2 Basic Unit Operating Manual Edition March 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us

More information

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:

More information

To connect the AC adapter:

To connect the AC adapter: Replacing the AC Adapter Replacing the AC Adapter 3 Plug the power cord into a wall outlet. The power indicator turns on. To connect the AC adapter: Connect the power cord to the AC adapter. Power indicator

More information

PRIMERGY TX150 S5 Server

PRIMERGY TX150 S5 Server PRIMERGY PRIMERGY TX150 S5 Server Options Guide Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001155 Fax: 0 700 / 372 00000 TX150

More information

PRIMERGY CX400 S2 Server Enclosure

PRIMERGY CX400 S2 Server Enclosure Operating Manual - English PRIMERGY CX400 S2 Server Enclosure Operating Manual Edition December 2013 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of

More information

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May 2004 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc.

More information

HP ProLiant DL165 G7 Server

HP ProLiant DL165 G7 Server HP ProLiant DL165 G7 Server Installation Instructions Part Number 601464-003 Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 LFF HDD Item Description 1 Thumbscrews

More information

PRIMERGY RX200 S5. Operating Manual

PRIMERGY RX200 S5. Operating Manual PRIMERGY RX200 S5 Operating Manual Edition April 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID 17 March 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc. All rights reserved. Overview Xserve RAID

More information

FUJITSU Server PRIMERGY RX2510 M2

FUJITSU Server PRIMERGY RX2510 M2 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX2510 M2 Upgrade and Maintenance Manual June 2017 Comments Suggestions Corrections The User Documentation Department would like to know

More information

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date: Installation- and Operating instructions for CU8880-0010 Ethernet Controller with USB Input Version: 1.4 Date: 2018-04-12 Table of contents Table of contents 1. 2. 3. 4. 5. General instructions 2 Notes

More information

English ETERNUS CS800. Getting Started Guide

English ETERNUS CS800. Getting Started Guide English ETERNUS CS800 Getting Started Guide Edition April 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion on this manual. Your feedback helps us

More information

PRIMERGY RX200 Server System

PRIMERGY RX200 Server System PRIMERGY PRIMERGY RX200 Server System Operating Manual Xenia Fierley Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001--157 Fax: (++49) 700

More information

System Board D3031 for PRIMERGY RX200 S6

System Board D3031 for PRIMERGY RX200 S6 Technical Manual - English System Board D3031 for PRIMERGY RX200 S6 Technical Manual Edition August 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

FUJITSU Server PRIMERGY RX1330 M1

FUJITSU Server PRIMERGY RX1330 M1 Upgrade and Maintenance Manual - English FUJITSU Server PRIMERGY RX1330 M1 Upgrade and Maintenance Manual August 2014 Comments Suggestions Corrections The User Documentation Department would like to know

More information

Dell XPS 14z Owner s Manual

Dell XPS 14z Owner s Manual Dell XPS 14z Owner s Manual Computer model: L412z Regulatory model: P24G series Regulatory type: P24G001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

The activities described in these upgrade instructions may only be performed by engineers or maintenance/technical staff.

The activities described in these upgrade instructions may only be performed by engineers or maintenance/technical staff. Introduction The upgrade instructions show how to remove the standard power supply and replace it with a hotplug power supply. The following steps only apply to the PRIMERGY 400 and 00 tower servers.!

More information

PRIMERGY RX300 S5. Operating manual

PRIMERGY RX300 S5. Operating manual PRIMERGY RX300 S5 Operating manual Edition september 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

PRIMERGY TX300 S4. Options Guide

PRIMERGY TX300 S4. Options Guide PRIMERGY TX300 S4 Options Guide Edition April 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our

More information

Operating Manual - English. RDX USB 3.0 QuikStor Drive

Operating Manual - English. RDX USB 3.0 QuikStor Drive Operating Manual - English RDX USB 3.0 QuikStor Drive December 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps

More information

ThinkCentre Hardware Installation and Replacement Guide. Machine Types 6062, 6065, 6071, 6076, 6089, 7103, 9011, 9014, 9071, 9089, 9162, 9182, 9303

ThinkCentre Hardware Installation and Replacement Guide. Machine Types 6062, 6065, 6071, 6076, 6089, 7103, 9011, 9014, 9071, 9089, 9162, 9182, 9303 ThinkCentre Hardware Installation and Replacement Guide Machine Types 6062, 6065, 6071, 6076, 6089, 7103, 9011, 9014, 9071, 9089, 9162, 9182, 9303 ThinkCentre Hardware Installation and Replacement Guide

More information

PRIMERGY BX400 S1 System Unit

PRIMERGY BX400 S1 System Unit Options Guide - English PRIMERGY BX400 S1 System Unit Options Guide December 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your

More information

Intel NUC Kit NUC6CAYS User Guide

Intel NUC Kit NUC6CAYS User Guide Intel NUC Kit NUC6CAYS User Guide Regulatory Model NUC6CAY 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices and regulatory

More information

PRIMERGY BX630 S2 Scalable Server Blade. Options Guide

PRIMERGY BX630 S2 Scalable Server Blade. Options Guide PRIMERGY BX630 S2 Scalable Server Blade Options Guide Edition October 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01 PNOZ m ES RS232 Configurable Control System PNOZmulti Operating Manual-1002701-EN-01 This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies

More information

PRIMERGY RX300 S3 Server. Options Guide

PRIMERGY RX300 S3 Server. Options Guide PRIMERGY RX300 S3 Server Options Guide Edition June 2007 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize

More information

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume

More information

Chassis (FRU) Replacement Guide

Chassis (FRU) Replacement Guide SIEM9750 Release 1.0 Chassis (FRU) Replacement Guide Issue: 02 Date: 2011-11-07 Page 1 of 26 This document is intended for Symantec support personnel, IBM, or other authorized Symantec Service Partners.

More information

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation Luminato Installation Manual Teleste Corporation Mounting Instructions Mechanical Mounting Luminato Mechanical Installation, agile_59300316, rev0044 Introduction 1 Contents Introduction 4 General... 4

More information

answers SCENIC P / SCENICO P / SCENIC Edition X100 Getting Started English

answers SCENIC P / SCENICO P / SCENIC Edition X100 Getting Started English answers 2 Getting Started SCENIC P / SCENICO P / SCENIC Edition X100 English Are there...... any technical problems or other questions which you would like to be clarified? Please contact: your sales partner

More information

System Board D3034 for PRIMERGY RX100 S7

System Board D3034 for PRIMERGY RX100 S7 Technical Manual - English System Board D3034 for PRIMERGY RX100 S7 Technical Manual Edition August 2012 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide Intel NUC Kit DN2820FYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety

More information

D1210H dimmer pack. user manual

D1210H dimmer pack. user manual D1210H dimmer pack user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 13.08.2015,

More information

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

Chapter 4 Replacement Procedures

Chapter 4 Replacement Procedures Chapter 4 Replacement Procedures 4 4-ii Satellite P30 Series Maintenance Manual Chapter 4 Contents 4.1 General... 4-1 4.2 Battery... 4-7 4.3 PC Card... 4-8 4.4 HDD... 4-10 4.5 Optical Drive Module... 4-12

More information

After completing this chapter, you will meet these objectives:

After completing this chapter, you will meet these objectives: 3.0 Introduction Assembling computers is a large part of a technician's job. As a technician, you will need to work in a logical, methodical manner when working with computer components. As with any learned

More information

Dell XPS L702X Service Manual

Dell XPS L702X Service Manual Dell XPS L702X Service Manual Regulatory model: P09E series Regulatory type: P09E002 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

DPX-620III 6-Ch. dimmer pack. user manual

DPX-620III 6-Ch. dimmer pack. user manual DPX-620III 6-Ch. dimmer pack user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 28.08.2017,

More information

Dell Edge Gateway. Service Manual Series

Dell Edge Gateway. Service Manual Series Dell Edge Gateway 5000 Series Service Manual Computer Model: Dell Edge Gateway 5000/5100 Regulatory Model: N01G/N02G Regulatory Type: N01G001/N02G001 Notes, cautions, and warnings NOTE: A NOTE indicates

More information

EVGA assumes you have purchased all necessary parts needed to allow for proper system functionality.

EVGA assumes you have purchased all necessary parts needed to allow for proper system functionality. Before You Begin Parts NOT in the Kit This kit contains all the hardware necessary to install and connect your new EVGA e-7050/610i GPU motherboard with integrated GeForce graphics processing. However,

More information

ThinkStation P320 Tiny User Guide and Hardware Maintenance Manual

ThinkStation P320 Tiny User Guide and Hardware Maintenance Manual ThinkStation P320 Tiny User Guide and Hardware Maintenance Manual Machine Types (MTs): 30C1 (Energy Star), 30C2 (Energy Star), and 30C3 (Energy Star) Note: Before using this information and the product

More information

PRIMERGY BX920 S3 Server Blade

PRIMERGY BX920 S3 Server Blade Upgrade and Maintenance Manual - English PRIMERGY BX920 S3 Server Blade Upgrade and Maintenance Manual Edition February 2014 Comments Suggestions Corrections The User Documentation Department would like

More information

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE Intel NUC Kit DC53427HYE User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety

More information

PRIMERGY BX630 S2 Scalable Server Blade. Operating Manual

PRIMERGY BX630 S2 Scalable Server Blade. Operating Manual PRIMERGY BX630 S2 Scalable Server Blade Operating Manual Edition October 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback

More information

DIVAR IP 2000 DIP N, DIP HD, DIP HD. en Quick Installation Guide

DIVAR IP 2000 DIP N, DIP HD, DIP HD. en Quick Installation Guide DIVAR IP 2000 DIP-2040-00N, DIP-2042-2HD, DIP-2042-4HD en Quick Installation Guide DIVAR IP 2000 Table of Contents en 3 Table of contents 1 Safety precautions 4 1.1 General safety precautions 4 1.2 Electrical

More information