1 WARNING! RISK OF FIRE OR ELECTRICAL SHOCK Disconnect power before installing or servicing. WARNING: Risk of fire or electrical shock. Luminaire wiring, power supply, or other electrical parts may be damaged when drilling for installation of retrofit assembly hardware. Inspect wiring and components for damage. WARNING: Risk of fire or electric shock. Do not alter, relocate, or remove wiring, lampholders, power supply or any other electrical component if not instructed to. WARNING: Risk of fire or electric shock. Installation of this retrofit assembly requires a person familiar with the construction and operation of the luminaire's electrical system and the hazards involved. If not qualified do not attempt installation. Contact a qualified electrician. WARNING: Risk of fire or electrical shock. Install this kit only in the luminaires that have the construction features and dimensions shown on the drawings. -Only those open holes indicated in the drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components. -Verify that supply wiring voltage matches power supply voltage by comparing it with power supply label. -Make all electrical and grounded connections in accordance with the National Electric Code (NEC) and any other applicable local code requirements. -THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION. -LED RETROFIT LUMINAIRE CONVERSION FOR USE IN ANY FLORESCENT LINEAR LUMINAIRES IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED WITH THIS RETROFIT KIT. CAUTION: RISK OF INJURY. - Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance. -Allow lamp/luminaire/driver to cool before handling. NOTICE: RISK OF PRODUCT DAMAGE- Failure to follow instructions could result in damage to product and void ALL warranties. -Never connect components under load. -Do NOT mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation. -Do NOT restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection of conduction cooling. THESE KITS CAN ONLY BE INSTALLED IN HOUSINGS WITH THE FOLLOWING MINIMUM DIMENSIONS. 2' KIT -- 24" LONG X 3.375"WIDE X 1.750"TALL. 4' KIT -- 48" LONG X 3.375"WIDE X 1.750"TALL. 6' KIT -- 72" LONG X 3.375"WIDE X 1.750"TALL. 8' KIT -- 96" LONG X 3.375"WIDE X 1.750"TALL.

2 WARNING: Before proceeding, read all instructions carefully to insure proper and safe installation. WARNING: Risk of fire or electrical shock. Disconnect power before installing or servicing. WARNING: Risk of electrical shock. High temperatures inside luminaire. Make certain line voltage corresponds with ballast's primary voltage. (See ballast label). WARNING: Risk of fire or electric shock. Install this kit only in the luminaires that has the construction features and dimensions shown in the photographs and/or drawings. WARNING: Risk of fire or electric shock. If not qualified, do not attempt installation. Contact a qualified electrician. WARNING: This product must be installed in accordance with the applicable installation code by a person familiar with construction and operation of the product and the hazards involved. WARNING: To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. WARNING: Do not touch the LEDs or place them face down on a surface as damage may occur. Doing so could contribute to premature failure. IMPORTANT: When removing lamps, always wear eye protection. Make sure area below fixture is clear. IMPORTANT: Not every unit is identical! Placement of proper luminaire section (by length, emergency option, etc.) within each row is important. Refer to layout drawing to verify row identification, product location, and feed points! Note: Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. 1. CHECK PARTS LIST. G. """" ""' ZIZIZZ Ill I I ZI ZIZZZZ Z:ZIU IZZZI ZZZIZIZI I - ==================.=iii =IIIIZZ znz ZZ Z:UU IZIZZZ ZZZZI IZIZIZZZ 8FT KIT: TW0 2 4FT PANELS. TW0(2) LED BOARDS PER PANEL ONE! J 40W DRIVER. ONE 1 SURGE PROTECTOR. THREE 3) _#6 SELF DRILLING SCREWS. (FOR DRIVER & SURGE EIGHT(8) #"8 SELF DRILLING SCREWS. (FOR MOUNTING PLATE) TW0(2) ADHESIVE BACKED WIRE CLIPS. r PROTECTOR) (OPTIONAL STEP DOWN TRANSFORMER ALSO AVAILABLE SHIPPED SEPARATE G...,...,JJ&....;;;;:-- 6FT KIT: ONE(1) 6FT PANEL. THREE(3) LED BOARDS. ONE 1 30W DRIVER. ONE 1 1 SURGE PROTECTOR. THR E 3) #6 SELF DRILLING SCREWS. (FOR DRIVER & SURGE PROTECTOR) SIX(6) #8 SELF DRILLING SCREWS. (FOR MOUNTING PLATE) (OPTIONAL STEP DOWN TRANSFORMER TW0(2) ADHESIVE BACKED WIRE CLIPS. ALSO AVAILABLE, SHIPPED SEPARATE 4FT KIT: ONE 1 4FT PANEL. TW0(2) LED BOARDS. ONE l1 25W DRIVER. ONE 1 SURGE PROTECTOR. THR E 3) #6 SELF DRILLING SCREWS. (FOR DRIVER & SURGE FOUR(4) #8 SELF DRILLING SCREWS. (FOR MOUNTING PLATE) TWO 2 ADHESIVE BACKED WIRE CLIPS. PROTECTOR) (OPTIONAL STEP DOWN TRANSFORMER 2FT KIT: """ ii liiiil ON E 2FT PANEL. ONE( 1) LED BOARDS. ONE l 12W DRIVER. ONE 1 SURGE PROTECTOR. THR (3) #6 SELF DRILLING SCREWS. (FOR DRIVER & SURGE PROTECTOR) TW0(2) #8 SELF DRILLING SCREWS. (FOR MOUNTING PLATE) (OPTIONAL STEP DOWN TRANSFORMER ONE( 1) ADHESIVE BACKED WIRE CLIP. ALSO AVAILABLE, SHIPPED SEPARATE LS/Industries Inc Alliance Road + Cincinnati, OH Fax (513) Page 2 of 6

3 THE FOLLOWING INSTRUCTIONS ARE REPRESENTATIVE OF ALL KITS LAMP HOLDER & LEADS (REMOVE.DISCARD) HOUSING COVER (REMOVE BUT KEEP) -OLD HOUSING OLD BALLAST (CUT AND DISPOSE OF LAMP HOLDER LEADS & BALLASTLEADS IFBALLAST LEFT IN HOUSING) LAMPS -- (REMOVE.DISCARD) 2.) SHUT OFF POWER TO EXISTING FIXTURE. REMOVE EXISTING LAMPS. BALLAST COVERS LAMP HOLDERS & LAMP HOLDER WIRING. DO NOT DISPOSE OF HOUSING COVER OR CORRESPONDING SCREWS! DISCONNECT POWER FROM EXISTING BALLAST. EXISTING BALLAST CAN REMAIN IF IT DOES NOT INTERFERE WITH INSTALLATION OF NEW DRIVER OR DRIVER/STEP DOWN COMBINATION. DISPOSE OF /RECYCLE LAMPS AND LAMP HOLDERS APPROPRIATELY PER STATE AND LOCAL CODES. DRIVER LED BOARD/PANEL SURGE PROTECTOR DIMMING LEADS (CAPPED OFF) DO NOT USE! 3.) REMOVE DRIVER & SURGE PROTECTOR FROM BACK OF LED RETROFIT PANEL BY REMOVING SCREWS. DRIVER & SURGE PROTECTOR SHIPPED SECURED TO PANEL TO PREVENT DAMAGE DURING TRANSPORT. NOTE: ALL DRIVERS ARE RATED AC INPUT. IF SUPPLY VOLTAGE IS 347/480 A STEP DOWN TRANSFORMER ORDERED SEPARATELY IS REQUIRED. STEP DOWN INSTRUCTIONS PAGE 6. l Ext Fax LS/Industries Inc Alliance Road + Cincinnati, OH Fax (513) Page 3 of6

4 OFFSET STRIP SHOWN LED DRIVER STEP DOWN TRANSFORMER (OPTIONAL, SEE PAGE 6) WIRING OFF BOTH ENDS ON 6 & 8FT KITS 4.) USE PROVIDED SELF DRILLING SCREWS TO MOUNT DRIVER & SURGE PROTECTOR INSIDE EXISTING HOUSING. USE ADHESIVE BACKED WIRE CLIPS TO CAPTIVATE LEADS FROM DRIVER TO RETROFIT PANEL. PANEL IS NOW TETHERED IN PLACE. IMPORTANT: DRIVER MUST BE MOUNTED MINIMUM OF 3" FROM END OF HOUSING AND A MINIMUM OF 3" FROM STEP DOWN TRANSFORMER IF EQUIPPED. DISCONNECT PLUG (PROVIDED BY LSI) NOTES: SEE BALLAST FOR CURRENT AND VOLTAGE. HOT LEAD TO BLACK COMMON LEAD TO WHITE GROUND LEAD TO GREEN 5.) ATIACH POWER SUPPLY USING UL LISTED WIRE CONNECTORS. IMPORTANT NOTE! EXISTING MASTER/AUXILIARY WIRING SCHEMES INCOMPATIBLE WITH LED RETROFIT. POWER MUST BE ROUTED TO EACH DRIVER. Page4 of6 LSI Industries Inc Alliance Road + Cincinnati, OH Fax (513)

5 --- GAP FOR WIRING OLD SCREWS 6.) REATTM:H FIXTURE COVER USING lhe SCREWS REMOVED E'ARUER. BE SURE TIMT lhe LOOS CONNECTING lhe ORNER TO lhe LED PANEL RUN lhrough lhe GAPS CR A1ED BY REMOVING lhe I.AMP HW>ERS. NOlE: DO NOT MJJ1fl WIRES TO BECOME PINCHED BEIWEEN HOUSING AND COVER! OLD HOUSING LED BOARD/PANEL 7.) USING PROVIDED TEI< SCREWS. ATTM:H LED PANEL TO lhe EXISTING BAl..lm COVER. IMPORTANT: MAKE SURE GAPS FOR WIRE WAYS ME COVERED BY lhe RETROFIT PANELi IF INSTM.LED CORRECTLY lhe LEDS SHOULD BE NE'AR lhe CENTER OF lhe FIXTURE AND lhe TABS ON lhe RETROFIT KIT SHOULD COMPLEIB.Y COVER lhe WIRE WAYS ON B01H ENDS. FIXTURE NOW ROOY TO BE ENERGIZED. LSI Industries Inc Alliance Road + Cincinnati, OH Fax (513) Page 5 of 6

6 OPTIONAL STEP DOWN TRANSFORMER INSTALLATION BLUE FROM STEP DOWN TO BLACK FROM DRIVER STEP DOWN 4A.) USE PROVIDED SELF DRILLING SCREWS TO MOUNT STEP DOWN TRANSFORMER INSIDE EXISTING HOUSING. CONNECT TO DRIVER AS SHOWN ABOVE. IMPORTANT: DRIVER MUST BE MOUNTED MINIMUM OF 3 11 FROM END OF HOUSING AND A MINIMUM OF 3 11 FROM STEP DOWN TRANSFORMER (IF EQUIPPED). DISCONNECT PLUG (PROVIDED BY LSI) NOTES: SEE BALLAST FOR CURRENT AND VOLTAGE. HOT LEAD TO RED COMMON LEAD TO WHITE GROUND LEAD TO GREEN 48.) ATIACH POWER SUPPLY USING UL LISTED WIRE CONNECTORS. IMPORTANT NOTE! EXISTING MASTER/AUXILIARY WIRING SCHEMES INCOMPATIBLE WITH LED RETROFIT. POWER MUST BE ROUTED TO EACH DRIVER. LSI Industries Inc Alliance Road + Cincinnati, OH Fax (513) Page 6 of 6

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE www.osram-americas.com S90655 OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE OSRAM ReliaSys TM Outdoor LED Retrofit Kit is an alternative to high-intensity discharge (HID) lamps up to 400W (MH)

More information

CHANNEL LETTER LIGHTING UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE

CHANNEL LETTER LIGHTING UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE UNIQUE LIGHTING SOLUTIONS LIGHTING WARNING -Installation must only be performed by a licensed electrician. -To prevent death, injury or damage to property this product must be installed in accordance to

More information

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

Installation and Operations Manual. Electronic copies available at (Rev_ )

Installation and Operations Manual. Electronic copies available at (Rev_ ) Installation and Operations Manual Electronic copies available at www.aquariitech.com/downloads/axceleronmanual Axceleron Installation and Operations Manual AXCELERON FIXTURE INSTALLATION... 1 Introduction...

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions.

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

Installation Instructions

Installation Instructions 50ES, 50EZ, 50GL, 50GS, 50GX, 50JS, 50JX, 50JZ, 50SD, 50SZ, 50VL, 50VT, 50XP, 50XZ 601A, 602A, 602B, 604A, 604B, 604D, 607C, 701A, 702A, 702B, 704A, 704B, 704D, 707C PA1P, PA2P, PA3P, PH1P, PH2P, PH3P

More information

BoxLED DS Plus (Double Side) BX-DS-PL; BX12BA-W4F Signage Lighting System INSTALLATION GUIDE

BoxLED DS Plus (Double Side) BX-DS-PL; BX12BA-W4F Signage Lighting System INSTALLATION GUIDE www.osram-americas.com/signage BoxLED DS Plus (Double Side) BX-DS-PL; BX12BA-W4F Signage Lighting System INSTALLATION GUIDE WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION TO AVOID ELECTRICAL

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

LED Gooseneck light FEATURES AND BENEFITS: ORDERING MATRIX: LED GOOSENECK LIGHT:

LED Gooseneck light FEATURES AND BENEFITS: ORDERING MATRIX: LED GOOSENECK LIGHT: ASD LED Gooseneck Barn Lights couple rustic style with modern LED technology. This timeless classic was frequently used on barns, warehouses, and industrial complexes during the early 2th century and is

More information

Principal LED Street Stik Fluorescent Bulb Replacements

Principal LED Street Stik Fluorescent Bulb Replacements Principal LED Street Stik Fluorescent Bulb Replacements LED Retrofit Guide (PL-RT1-001) WARNING Installation must only be performed by a licensed electrician. To prevent death, injury or damage to property

More information

PLCC SMT Down Light. Features. High Brightness SMD LED Light source Ecological Friendly Fully Integral Design

PLCC SMT Down Light. Features. High Brightness SMD LED Light source Ecological Friendly Fully Integral Design www.edison-opto.com Solid-State Lighting Series PLCC SMT Down Light DATASHEET Features High Brightness SMD LED Light source Ecological Friendly Fully Integral Design Energy Efficient General Information...

More information

PEREGRINE SERIES RETROFIT INSTALLATION GUIDE

PEREGRINE SERIES RETROFIT INSTALLATION GUIDE 06.05.17 HanleyLED H100W-PPS524V Spec Sheet SOLUTIONS THAT MAKE SENSE PEREGRINE SERIES RETROFIT INSTALLATION GUIDE Light Up New Markets Your Local Distributor: Grimco US www.grimco.com 800.542.9941 Canada

More information

Linearray PD Retrofit Kit

Linearray PD Retrofit Kit Linearray Retrofit and Installation Instructions 1. Scope All Installations should be performed by qualified personnel and all electrical work should be performed in accordance to NEC and local code. These

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be

More information

ibright LED Tube Model: HFL C-16 HFL C-16 Performance summary Performance summary in 2 tubes troffer

ibright LED Tube Model: HFL C-16 HFL C-16 Performance summary Performance summary in 2 tubes troffer ibright LED Tube Model: HFL-80004-12060C-16 HFL-80005-12060C-16 Performance summary Input: 16W, 100~277VAC, 0.135A Luminous efficacy: Typ. 100 lm/w Lumens: 1600lm CCT: 4000K&5000K Color Accuracy: CRI 85,

More information

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Series Amp Pad Mount Quick Connect Input and Output Power Panels Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.

More information

72In LED Lit Nutcracker Item # CAUTION: IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

72In LED Lit Nutcracker Item # CAUTION: IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS CAUTION: IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS FOR INDOOR and OUTDOOR USE The product and its adapter are intended for indoor and outdoor use. When product is used in outdoor

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV OVERVIEW The STR9 ELV is a long run, low power, linear surface mount LED lighting system designed for exterior architectural lighting applications. This guide contains important information on planning

More information

Series Amp Quick Connect Input and Output Power Panels

Series Amp Quick Connect Input and Output Power Panels Series 300 1200-1600 Amp Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury. WARNING is

More information

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443 Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443 IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY. PARTS LIST: 2 Metal Plate Stands 5 Greenery

More information

LED Shoe Box light FEATURES AND BENEFITS: ORDERING MATRIX: LED SHOE BOX LIGHT:

LED Shoe Box light FEATURES AND BENEFITS: ORDERING MATRIX: LED SHOE BOX LIGHT: ASD slim shoe box lights use up to 8% less energy than metal halide or high pressure sodium lights and put out a much nicer light. Lights up instantly, no warm-up period needed, type III distribution,

More information

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all

More information

ft Aspen Fir Item # Commercial ITEM Lights

ft Aspen Fir Item # Commercial ITEM Lights 7.57.5 ft Aspen Fir Item #142027 Commercial ITEM Lights PARTS LIST A. BOTTOM B. LOWER MIDDLE C. UPPER MIDDLE D. TOP E. TREE STAND NUMBER OF PERSONS RECOMMENDED FOR ASSEMBLY: 2 SKU 142027 7.5 ASPEN FIR

More information

GOLDENI. Owners Manual & Safety Instructions. English. model# GOLDi600. Copyright 2017 Smart Grow Technologies, INC All Rights Reserved

GOLDENI. Owners Manual & Safety Instructions. English. model# GOLDi600. Copyright 2017 Smart Grow Technologies, INC All Rights Reserved GOLDENI 600 model# GOLDi600 English Copyright 2017 Smart Grow Technologies, INC All Rights Reserved Owners Manual & Safety Instructions INTRODUCTION This User Manual is for Smart Grow Technologies (SGS):

More information

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 8020-STC Kelvin Standard Triaxial Connector Card Description The Model 8020-STC Kelvin Standard

More information

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel. LX Breaker Control Panels Installation and Setup Procedure Hubbell Building Automation, Inc. 9601 Dessau Road Building One Suite 100 Austin, Texas 78754 512-450-1100 512-450-1215 Fax www.hubbell-automation.com

More information

M215-Z Safety Information (M LL-IG-ZC)

M215-Z Safety Information (M LL-IG-ZC) M215-Z SAFETY M215-Z Safety Information (M215-60-2LL-IG-ZC) This document contains important instructions to use during installation of the M215-Z Zep Compatible Microinverters. To reduce the risk of electrical

More information

LED SMD FLOODLIGHT with knuckle

LED SMD FLOODLIGHT with knuckle LED SMD Compact Floodlights are a great step forward in the lighting industry. Their energy consumption is much lower and performance is often higher than that of all other widely used types of fixtures.

More information

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS FOR USE WITH: HAMMOND Organ Models L-100, M-100 Series, M-l, M-2, M-3 LESLIE Speaker Models 760, 770, 825 KIT CONTENT Console Connector Assembly 043075

More information

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 8020-KHV Kelvin Keithley Triaxial Connector Card Description The Model 8020-KHV Keithley HV Connector

More information

Upgrading LVDS Cables Instruction Sheet

Upgrading LVDS Cables Instruction Sheet Upgrading LVDS Cables Instruction Sheet INTRODUCTION Use the following instructions to replace the LVDS cables in CP2000-M/MR projectors. The new cables are slightly longer in length and allow for better

More information

Z-Wave Certified Wireless Lighting Control. Auxiliary Switch ZW2001 ZW2002 rev. 09/01/11

Z-Wave Certified Wireless Lighting Control. Auxiliary Switch ZW2001 ZW2002 rev. 09/01/11 Z-Wave Certified Wireless Lighting Control Auxiliary Switch 45610 ZW2001 ZW2002 rev. 09/01/11 This auxiliary switch is a component of the JASCO Z-Wave lighting control system and is designed to work with

More information

3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions

3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions 3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions Safety Information Read, understand and follow all safety information contained in these user instructions prior to use of the

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS WARNING RISK OF SEVERE INJURY OR DEATH To reduce the risk of death,

More information

Model 2657A-LIM-3 LO Interconnect Module

Model 2657A-LIM-3 LO Interconnect Module Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2657A-LIM-3 LO Interconnect Module User's Guide Description The Model 2657A-LIM-3 LO Interconnect

More information

E1135C PDU and Pod Upgrade Procedure

E1135C PDU and Pod Upgrade Procedure E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support

More information

PV Rapid Shutdown device

PV Rapid Shutdown device PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.

More information

Flexoled FTP3HP RGB LED DMX Driver

Flexoled FTP3HP RGB LED DMX Driver Flexoled FTP3HP RGB LED DMX Driver User Manual + 12-24V DMX INPUT DMX OUTPUT DC IN (12A MAX) DMX ADDRESS & DIMMER SETTINGS SWITCH 10 11 12 DMX MODE DIMMING MODE BUILT-IN MODE LOAD 4A PER CHANNEL (12A MAX)

More information

InSight Single Implement

InSight Single Implement Note: Indented items indicate parts Included in an assembly listed above Part name/description Part Number Quantity DirectCommand 4100544 1 Cable Install Kit 2000901-1 1 Module Mounting Plate Kit 2001358

More information

M250 (M LL) Safety

M250 (M LL) Safety M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical

More information

Wa r n i n g-wa r n i n g-wa r n i n g

Wa r n i n g-wa r n i n g-wa r n i n g Installation Instructions of the Power Analyzer Wa r n i n g-wa r n i n g-wa r n i n g Read and understand this manual before connecting device. Death, fire or serious injury can occur from using equipment

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215

More information

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com CVU-200-KIT 200 V Bias Tee Kit Description The CVU-200-KIT Bias Tee Kit consists of three 2600-RBT-200

More information

HL-DL. Direct View Architectural Delineation LED System INSTALLATION GUIDE

HL-DL. Direct View Architectural Delineation LED System INSTALLATION GUIDE Tel: + 1 905 569 6044 Email: info@ IG-HL-DL, 16-12-16 Page 1 / 7 The HL-DL is a long run modular LED lighting system designed for architectural delineation and data centers where long runs are necessary

More information

* * Agilent Power Distribution Unit (PDU) Installation Guide

* * Agilent Power Distribution Unit (PDU) Installation Guide Agilent Power Distribution Unit (PDU) Installation Guide For use with Agilent PDU kits and PDU installation kits for Agilent instrument racks June 2008 Edition 7 E0608 *5000-0039* 5000-0039 Notice The

More information

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount

More information

WARNING. General Information

WARNING. General Information Principal LED Sign Retrofit Installation Manual Kit Model: PL RT1 001 WARNING Retrofit Installation must only be performed by qualified personnel in accordance with the National Electric Code in the USA

More information

Always "On" UPS Systems Inc. USER MANUAL

Always On UPS Systems Inc. USER MANUAL Always "On" UPS Systems Inc. SMART HOME PROTECTOR USER MANUAL Bldg 1-150 Campion Road, Kelowna, BC, Canada, V1X 7S8 Phone: (250) 491-9777 Ext. 451, Fax: (250) 491-9775, Email: sales@alwaysonups.com Web

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information

ETC Installation Guide

ETC Installation Guide Unison Foundry Overview The Unison Foundry provides fully-rated 20A relays for switched power control with 0 10V dimming for compatible fluorescent ballasts and LED drivers. The provides two outputs of

More information

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product. LINE VOLTAGE TESTER USER S MANUAL CT101 Please read this manual carefully and thoroughly before using this product. KEY FEATURES Visual indication of AC or DC voltage Easy to use approved Safe for CAT

More information

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com CVU-3K-KIT 3 kv Bias Tee Kit Description The CVU-3K-KIT Bias Tee Kit consists of three bias tees for

More information

Principal LED Qwik Stik Fluorescent Bulb Replacements

Principal LED Qwik Stik Fluorescent Bulb Replacements Principal LED Qwik Stik Fluorescent Bulb Replacements LED Retrofit Guide (PL-RT1-001) WARNING Installation must only be performed by a licensed electrician. To prevent death, injury or damage to property

More information

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2600B-PM-1 200 V Protection Module with 1 A Clamp Description The Model 2600B-PM-1 200 V Protection

More information

Chore-Tronics IDM Board Instruction

Chore-Tronics IDM Board Instruction Chore-Tronics IDM Board Instruction Caution, Warning and Danger Decals have been placed on the equipment to warn of potentially dangerous situations. Care should be taken to keep this information intact

More information

HV-CS kv Edge Mount Triaxial Jack

HV-CS kv Edge Mount Triaxial Jack Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley HV-CS-1589 3 kv Edge Mount Triaxial Jack Installation Information Description The Keithley Instruments

More information

Model: CAM430MV Wired Multi-View Camera with License Plate / Rear Surface Mount Installation Manual Features

Model: CAM430MV Wired Multi-View Camera with License Plate / Rear Surface Mount Installation Manual Features Model: CAM430MV Wired Multi-View Camera with License Plate / Rear Surface Mount Installation Manual Features Fully Adjustable, Multiple Viewing Angle Smart Camera. High Resolution, 1/2 CMOS Color Camera

More information

PowerFlex 400 Frame G and H Replacement Procedure for Gate Power Board

PowerFlex 400 Frame G and H Replacement Procedure for Gate Power Board Service Bulletin PowerFlex 400 Frame G and H Replacement Procedure for Gate Power Board Contents This publication provides instructions for replacing the gate power board for PowerFlex 400 Frame G and

More information

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data: Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina Progressive Industries Warranty Progressive warrants its products are free from defects in materials and workmanship for a period of three years. This is in lieu of all other warranties, obligations, or

More information

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Model 8010 High Power Device Test Fixture Interconnection Reference Guide Model 8010 High Power Device Test Fixture Interconnection Reference Guide Safety precautions Observe the following safety precautions before using this product and any associated instrumentation. Although

More information

Installation Guide for America Solar Wholesale Photovoltaic Modules

Installation Guide for America Solar Wholesale Photovoltaic Modules Installation Guide for America Solar Wholesale Photovoltaic Modules Mono Module Poly Module 1 ASW Photovoltaic Module Installation Guide Installation guide for American Solar Wholesale Photovoltaic modules

More information

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

PowerLogic ION7300 Series

PowerLogic ION7300 Series PowerLogic ION7300 Series Power and Energy Meter Advanced Field Retrofit Instructions August 2006 Danger This symbol indicates the presence of dangerous voltage within and outside the product enclosure

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A 8 Button RS232/IR Control Panel 500816 MuxLab Inc. 2016 94-000833-A / SE-000833-A SAFETY PRECAUTIONS To insure the best use from the product, please read all instructions carefully before using the device.

More information

C-POWER AC AUTOMATIC CONTROL

C-POWER AC AUTOMATIC CONTROL Issue 1 Print 1 C-POWER AC AUTOMATIC CONTROL INSTALLATION INSTRUCTIONS & OWNER S MANUAL Model: 93 ACMC100I A Charles Industries, Ltd. All rights reserved. Printed in the United States of America. Issue

More information

LED Wallpack with lenses Installation Instruction

LED Wallpack with lenses Installation Instruction ASD new generation of traditional wallpack with optic lenses is the premier choice for commercial and industrial lighting in a variety of settings, such as entryways, parking lots, garages, warehouses,

More information

Progressive Industries, Inc. EMS Electrical Management System

Progressive Industries, Inc. EMS Electrical Management System Progressive Industries, Inc. EMS Electrical Management System Complete Installation Guide and Operating Instructions for: Model EMS-LCHW50 Rated at 240V/50A Manufactured by: Progressive Industries, Inc.

More information

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS - For use with CONTROLTrack System Only When installing or using this track system, basic safety precautions should always be

More information

User Safety. Electrical Safety. Phaser 4500 Laser Printer

User Safety. Electrical Safety. Phaser 4500 Laser Printer User Safety Your printer and the recommended supplies have been designed and tested to meet strict safety requirements. Attention to the following information will ensure the continued safe operation of

More information

PTo 150/ DIM HCI 150 W, HQI 150, NAV 150 W, and other similar commercially available 150 W lamps System wattage:

PTo 150/ DIM HCI 150 W, HQI 150, NAV 150 W, and other similar commercially available 150 W lamps System wattage: data Reference: amp: HCI 150 W, HQI 150, AV 150 W, and other similar commercially available 150 W lamps System wattage: 160 W ± 5 W amp wattage: 147 W ± 5 W Ballast efficiency: ~ 91 % ine voltage: 220

More information

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Section Page Introduction 1 Materials Provided 1 I) Safety Instructions 1 A) Inverter Safety Instructions 1 B) Battery Safety

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

Power Supply Installation

Power Supply Installation Power Supply Module Overview, on page Installation Guidelines, on page 4 Installing or Replacing an AC Power Supply, on page 6 Installing a DC Power Supply, on page 7 Finding the Power Supply Module Serial

More information

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers Answer Modular Power Change of Height Harness Power Kits Receptical Covers NOTE: Unused modular electrical connector openings are not required to be capped. NOTE: The electrician can cut conduit and wire

More information

ORB TM 4-20 ma Input Box Installation & Operation Manual

ORB TM 4-20 ma Input Box Installation & Operation Manual IOM ORB TM 4-20 ma Input Box Installation & Operation Manual ORB TM 4-20 ma Input Box Installation & Operation Manual CONTENTS I. HANDLING & STORAGE... 1 Inspection and Handling Disposal and Recycling

More information

Plasma Panel Replacement Guide DU-42PX12X

Plasma Panel Replacement Guide DU-42PX12X Plasma Panel Replacement Guide DU-42PX12X Panel Replacement: At this point, the panel has been determined to be defective and replacement is necessary. Upon receiving the replacement panel, it must be

More information

EC Series. Safety Guide

EC Series. Safety Guide EC Series Safety Guide R5906018/02 01/07/2017 Barco Inc, Image Processing 3078 Prospect Park Drive, Rancho Cordova, CA, 95670, USA Phone: +1 916 859-2500 Fax: +1 916 859-2515 Support: www.barco.com/en/support

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

LED Shoe Box light ORDERING MATRIX: LED SHOE BOX LIGHT:

LED Shoe Box light ORDERING MATRIX: LED SHOE BOX LIGHT: This slick and modem luminaire ASD Shoebox has been designed to handle Catalog number any environment with a beautiful slim line design. Optional photocell allows Notes for further energy saving. Save

More information

Blitzer Strobe. User Manual. Order code: EQLED366

Blitzer Strobe. User Manual. Order code: EQLED366 Blitzer Strobe User Manual Order code: EQLED366 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make

More information

Orbital smart Tunable Downlight

Orbital smart Tunable Downlight Commissioning The ceiling surface must be flat and smooth to ensure a good fit. Push the spring clips upwards and fit into the ceiling hole. See Fig 1. Push the unit up until firmly in position, ensuring

More information

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE 1. Circuit Breaker Tripping 2. Circuit Overload 3. Short Circuit 4. Ground Fault 5. Ground Fault Circuit Interrupter (GFCI) Tripping SAFETY PRECAUTIONS Basic

More information

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series Owner s Manual 19 Pro Series Rack Mount (RK) Faceplate Isolate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) Colours Restore. Power Conditioners Audio / Video Power Isolation

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

ew Downlight SM Installation Guide An EssentialWhite Product

ew Downlight SM Installation Guide An EssentialWhite Product Installation Guide ew Downlight SM An EssentialWhite Product ew Downlight SM Powercore is a low-profile, surface-mounted downlight for basic white illumination. The ew Downlight SM Powercore fixture is

More information

Installation Instructions for Rebel Chameleon TM 105XBRi Series LED Multi-Status Indicator in NEMA 4X Enclosures

Installation Instructions for Rebel Chameleon TM 105XBRi Series LED Multi-Status Indicator in NEMA 4X Enclosures Description The 105XBRi Series Chameleon Multi-Status LED Indicator is a UL and cul listed, multi-color LED signaling appliance which, when assembled in accordance with these installation instructions,

More information

diode led VALENT X SPECIFICATION SHEET 24VDC OVERVIEW FEATURES & BENEFITS COMPATIBLE CHROMAPATH CHANNELS

diode led VALENT X SPECIFICATION SHEET 24VDC OVERVIEW FEATURES & BENEFITS COMPATIBLE CHROMAPATH CHANNELS VALENT X diode led a division of elemental LED PREMIUM DIFFUSED LED FIXTURE 24VDC CUSTOMIZABLE DIMMABLE DRY LOCATION HIGH CRI SPECIFICATION SHEET 90+ OVERVIEW VALENT X Premium Diffused LED Fixture is designed

More information

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

M215 Safety (M LL-S22-IG / S23-IG / S24-IG) M215 SAFETY M215 Safety (M215-60-2LL-S22-IG / S23-IG / S24-IG) Important Safety Information This document contains important instructions to use during installation of the Enphase M215 Microinverter. To

More information

Installation Instructions MX LED Wall Wash Remodel

Installation Instructions MX LED Wall Wash Remodel 1 of 5 Risk of electrical shock. Disconnect power before servicing or installing luminaire. Risk of injury or damage. Luminaire will fail if not installed properly. Follow installation instructions. Risk

More information

Installation, Start-up and Operating Instructions

Installation, Start-up and Operating Instructions Installation, Start-up and Operating Instructions EVOLUTION SMART SENSOR FOR ZONING Cancels: NEW II ZONESMS-0-1 7-04 NOTE: Read the entire instruction manual before starting the installation. This symbol

More information

Part Name/Description Part Number Quantity

Part Name/Description Part Number Quantity Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Liquid Manure, Pinch Valve Kit 4200139 1 GEN 2 Large Module Mounting Kit 2001370 1 Deutsch

More information

M215 (M215-60) Safety

M215 (M215-60) Safety M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To

More information

CW-WW LEDWash USER MANUAL

CW-WW LEDWash USER MANUAL LEDWash CW-WW USER MANUAL 1 1.BEFORE YOU BEGIN What is included Ø 1 x Fixture Ø 1 x Power cable with plug Ø 1 x User Manua Unpacking Instructions Immediately upon receiving a fixture, carefully unpack

More information