Room Pressurization Controller Pneumatic Output
|
|
- Kathleen Sharp
- 5 years ago
- Views:
Transcription
1 Document No Room Pressurization Controller Pneumatic Output Product Description These instructions explain how to field install (pages 1 through 3) or replace (pages 3 through 4) a Room Pressurization Controller Pneumatic Output with or without Autozero Modules. Product Number Room Pressurization Controller Pneumatic Output Room Pressurization Controller Pneumatic Output with Autozero Modules N Room Pressurization Controller Board Pneumatic Output (replacement) Shipping carton includes a pre-assembled metal enclosure with controller board and cover, pneumatic output modules, Autozero Modules with brackets (optional), and four self-tapping/drilling screws. Installation Conventions Required Tools Equipment damage or loss of data may occur if you ds not follow procedures as specified. Electro-Static Discharge (ESD) wrist strap Small flat-blade screwdriver Medium flat-blade screwdriver Medium-duty electric drill 1/4 in. (6.35 mm) hex nut bit Portable Operator s Terminal with Controller Interface Software Rev. 2.0 or later (required for controller replacement only) Additional tools needed if not using self-tapping option: 1/4 in. (6.35 mm) hex nut driver 1/8 in. (3 mm) bit Prerequisites (Optional) Room temperature sensor installed Air velocity sensors installed in ducts A source of 24 Vac Class 2 power available Supply power to the unit is OFF An air supply line is available at the controller Expected Installation Time New controller installation Replacement (old controller has removable terminal blocks) 10 minutes 6 minutes Replacement (old controller does 16 minutes not have removable terminal blocks) NOTE: You may require additional time for database work at the field panel. New NOTE: These steps only refer to new installations. For replacement instructions, refer to pages 3-4. For Autozero Module installation, refer to instruction The following tasks can be performed by the electrician: 1. Loosen, but do not remove, the cover screws and remove the enclosure cover. Using the rear panel of the enclosure as a template (Figures 1 and 2), mark the location for the four screw holes where you will install the enclosure. 2. Do one of the following: If using the self-tapping screws: Using the drill and the hex nut bit, start the screws. (Screws do not require starter holes.) If not using the self-tapping screws: Drill four 1/8 in. (3 mm) pilot holes for the screws. Using the hex nut driver, start the screws. Item Number: , Rev. FA Page 1 of 7
2 Figure 1. Room Pressurization Controller Pneumatic Output without Autozero Modules. 3. Mount the enclosure on the screws and tighten them down with either the drill or hex nut driver. 4. Remove the appropriate knockouts. 5. Place the ESD wrist strap on your wrist and attach it to a good earth ground. 6. Connect the Local Area Network (LAN) trunk (Figure 4). Run the wiring through knockout. Page 2 of 7 Do not connect an earth ground to the Shield (S) terminal. 7. Connect the point wiring for the appropriate application. See Figure 7. See Table 1 for application descriptions. Run the wiring through knockout. The Controller s Digital Outputs (DOs) control 24 Vac loads only. The maximum rating is 12 VA for each DO. For higher VA requirements, 110 or 220 Vac requirements, separate transformers used to power the load, or DC power requirements, use an interposing 220 V 4-relay module (TEC Relay Module P/N ). NOTE: Each DO provides a Normally Open (NO) and a Common (C) terminal. Terminate both connections of a 24 Vac load directly to the controller board. NOTE: The 24 Vac H terminal is switched through a TRIAC to the NO terminations when the associated DO is energized. 8. If using a pressure mode switch, then follow the Room Pressurization Controller (RPC) Pressue Mode Switch nstallation Instructions ( ) included with the switch. 9. After the pressure mode switch is installed, wire the switch to DO8 and AI3 as described in the instructions. 10. Plug the Room Temperature Sensor cable into the RTS port on the controller board. See Figure 1. Run the cable through knockout. 11. Connect the power trunk as shown in Figure 5. DO NOT apply power to the controller. Run the wiring through knockout. 12. Replace the enclosure cover and tighten the cover screws.
3 The following task can be performed by the fitter: 13. Connect the tubing from the air velocity sensor pickups to the HI and LO ports outside of the enclosure. The supply pickup goes to the supply AVS ports, and the exhaust pickup goes to the exhaust AVS ports on the side of the enclosure. Make sure that the HI and the LO pressure sides of the sensors are connected to the HI and LO sensor ports on the controller (Figure 1) or Autozero Modules (Figure 2). Refer to Table 2 for air velocity sensor connections. The installation is complete. Replacement Instructions Replacement of a TEC requires you to record, re-enter, or update the initial point values of the controller you are replacing. These are the points marked with an asterisk (*) on the Controller Interface Software (CIS) display. NOTE: CIS Rev. 2.0 or later is required for controller replacement. The following tasks can be performed by the system specialist: 1. Place the ESD wrist strap on your wrist and attach it to a good earth ground. 2. Before disconnecting the old controller, do one of the following: NOTE: If the new controller has a newer firmware revision than the old controller, then skip to the third bullet. If the old controller communicates with the field panel, then update the controller initial values at the field panel. If the old controller does not communicate with the field panel, but communicates with the CIS, or if the controller is stand-alone, then record the initial values (those marked with an asterisk (*) on the CIS display). Record the values. If the old controller is not communicating at all, or if the controller you are installing has a newer firmware revision than the old controller, then while at the field panel, follow these steps: a. Obtain a field panel Point Definition Report for the LCTLR point. Record the values. b. View the initial value block. (This information is valid only since the last update was made). Record the values. c. Delete the LCTLR point from the field panel. 3. Replace the old controller as follows: The following tasks can be performed by the electrician: a. Remove power from the controller. b. If the old controller has the RTS plug between the LAN trunk and point terminations, then disconnect the wires from the power trunk terminal block. If the old controller has the RTS plug on the opposite end of the board from the power trunk terminal block, then remove the power trunk terminal block. c. Remove, in the following order, the controller s: LAN trunk terminal block DO8, AI3, and DI2 only room temperature sensor d. Loosen, but do not remove, the mounting screws. e. Lift and remove the old enclosure. f. Mount the new enclosure on the mounting screws and tighten them down with either the drill or hex nut driver. g. Remove the appropriate knockouts. h. If the old controller has the RTS plug between the LAN trunk and point terminations, then remove all terminal blocks (except the power trunk) from the new controller. If the old controller has the RTS plug on the opposite end of the board from the power trunk terminal block, then remove all terminal blocks. Page 3 of 7
4 i. Plug, in the following order, the controller s: pre-wired LAN trunk DO8, AI3, and DI2 j. If the old controller has the RTS plug between the LAN trunk and point terminations, then rewire power to the power trunk terminal block. If the old controller has the RTS plug on the opposite end of the board from the power trunk terminal block, then plug the power trunk terminal block from the old controller into the new controller. k. Connect the room temperature sensor. Run the wiring through knockout. l. Power up the controller. The following tasks can be performed by the fitter: m. Label and remove the polyethylene tubing from the old enclosure. n. After the new enclosure is in place, reconnect the polyethylene tubing. The following tasks can be performed by the system specialist: 4. Set the address and application at the new controller. 5. Based on what you did in Step 2, do one of the following: If you updated the initial values from the old controller at the field panel, then when you set the address and application for the new controller, the field panel will automatically send the initial values down to the new controller. Once this takes place, replacement is complete. If you manually recorded the initial values in the table, then enter them into the new controller. If a field panel is present, then update the controller s initial values. Replacement is complete. If there was no communication at the old controller, or the new controller has a newer firmware revision than the old controller, then enter the initial values into the new controller. At the field panel, add the LCTLR point and update the controller s initial values. The replacement is complete. Figure 2. Room Pressurization Controller Pneumatic Output with Autozero Modules. Page 4 of 7
5 Figure 3. Dimensions. Figure 4. FLN Trunk Wiring. Figure 5. Power Trunk Wiring. Page 5 of 7
6 Table 1. Application Descriptions. Application Description Figure 2215 CAV/VAV Room Pressurization with Hot Water Reheat 2217 VAV Room Pressurization with Hot Water Reheat 2219 CAV Room Pressurization with Hot Water Reheat NOTE: When wiring any actuator that uses a 0 to 10V control signal and ties AC neutral to DC common, an additional wire must connect the actuator AC neutral to the DC common of the PTEC/TEC AO being used to control the actuator. Table 2. Air Velocity Sensor Connections. Application Supply AVS HI and LO Exhaust AVS HI and LO 2215 Supply Pickup Exhaust Pickup 2217 Supply Pickup Exhaust Pickup 2219 Supply Pickup Exhaust Pickup The Room Pressurization Controller Pneumatic Output controls 24 Vac loads only. The maximum rating is 12 VA for each DO. For higher VA requirements, 110 or 220 Vac requirements, separate transformers used to power the load, or DC power requirements, use an interposing 220V 4-relay module (TEC Relay Module P/N ). Actuator Symbol Figure Vac Modulating Control. TEC Connection Function Terminal Connection Standard Color 1 H Supply (SP) G Red 2 C Neutral (SN) G0 Black 8 AO3 15 (+) -- C to AO3 16 (-) 0 to 10V input signal Common jumper Y Gray NOTE: Refer to the unit wiring diagrams or consult with the local representative if terminations are missing or are different. Page 6 of 7
7 Figure 7. Point Wiring for Applications 2215, 2217, and 2219 with Hot Water Reheat. Refer to Table 1 for Application Descriptions. Cyber security disclaimer Products, solutions and services from Siemens include security functions to ensure the secure operation of building automation and control, fire safety, security management, and physical security systems. The security functions on these products, solutions and services are important components of a comprehensive security concept. Drafting, implementing and managing a comprehensive and up-to-date security concept, customized to individual needs, is nevertheless necessary, and may result in additional plant- or site-specific preventive measures to ensure secure operation of your site regarding building automation and control, fire safety, security management, and physical security. These measures may include, for example, separating networks, physically protecting system components, user training, multi-level defensive measures, etc. For additional information on security as part of building technology and our product, solution and service offerings, please contact your Siemens sales representative or project department. We strongly recommend to always comply with our security advisories on the latest security threats, patches and other related measures. Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL USA Tel Your feedback is important to us. If you have comments about this document, please send them to SBT_technical.editor.us.sbt@siemens.com. Document No Printed in the USA Page 7 of 7
Room Pressurization Controller Electronic Output
Document No. 540-1033 Room Pressurization Controller Electronic Output Product Description These instructions explain how to field install or replace a Room Pressurization Controller (RPC) Electronic Output
More informationBACnet PTEC Terminal Box (VAV) Controller. Control Applications. Product Numbers. Product Description. Warning/Caution Notation
BACnet PTEC Terminal Box (VAV) Controller Generic Controller I/O Layout. See Wiring Diagram for application specific details. Control Applications 6600 through 6607 Product Description These instructions
More informationTEC VAV with 0-10V AO Heat. Modulation and CO2 Monitoring. Controller. Control Applications. Product Description. Accessories.
Document No. 540-1031 TEC VAV with 0-10V AO Heat Modulation and CO2 Monitoring Controller Generic Controller I/O Layout. See Wiring Diagram for application specific details. Control Applications 2843,
More informationBACnet PTEC Heat Pump Multi-Stage Controller. Control Applications. Product Description. Product Numbers. Warning/Caution Notation
BACnet PTEC Heat Pump Multi-Stage Controller Generic Controller I/O Layout. See Wiring Diagram for application specific details. Control Applications 6673, 6674 Product Description These instructions explain
More informationSiemens TEC Extended I/O Controller
Document No. 540-1028 TEC Extended I/O Controller Generic Controller I/O Layout. See Wiring Diagram for application specific details. Control Applications 2497 Product Description These instructions explain
More informationTEC Heat Pump Multi-Stage Controller. Control Applications. Accessories. Product Description. Product Numbers. Warning/Caution Notation
Document No. 540-1024 TEC Heat Pump Multi-Stage Controller Generic Controller I/O Layout. See Wiring Diagram for application specific details. Control Applications 2273 and 2274 Product Description These
More informationTEC Terminal Box (VAV) Controller
Document No. 540-1025 TEC Terminal Box (VAV) Controller Generic Controller I/O Layout. See Wiring Diagram for application specific details. Control Applications 2020 through 2027 Product Description These
More informationTEC Unit Conditioner Controller
Document No. 540-1026 TEC Unit Conditioner Controller Generic Controller I/O Layout. See Wiring Diagram for application specific details. Control Applications 2040 and 2041 2050 through 2054 Product Description
More informationBACnet PTEC Unit Conditioner/Fan Coil P. Controller. Control Applications. Accessories. Product Description. Warning/Caution Notation
Installation Instructions BACnet PTEC Unit Conditioner/Fan Coil Controller Figure 1. BACnet PTEC Unit Conditioner/Fan Coil Controller. Control Applications 6540, 6541, 6550, 6551, 6552, 6553 and 6554 Product
More informationTerminal Equipment Controller Enclosure
Document No. 550-196 Terminal Equipment Controller Enclosure Product Description A Terminal Equipment Controller enclosure is a general-purpose metal cabinet with a removable cover that houses an electronic
More informationLTEC Heat Pump DDC Controller
Document No. 09 Rev., May, 00 LTEC Heat Pump DDC Controller Product Description These instructions explain how to install or replace a LTEC (LonMark Terminal Equipment Controller) HP (Heat Pump) DDC Controller
More informationLTEC Unit Ventilator DDC Controller
Document No. 09 Rev., May, 00 LTEC Unit Ventilator DDC Controller Product Description These instructions explain how to install or replace a LTEC (LonMark Terminal Equipment Controller) UV (Unit Vent)
More informationTRUNK TX RX + - S + - S DO LEDS FLN TRUNK TERMINATIONS INPUT/OUTPUT TERMINATIONS TRANSMIT LED
Heat Pump Controller Single Stage COVR CONTROLLR BOARD MOUNTING HOL (2) C H DO 1 DO 2 DO 3 DO 4 DO 5 DO 6 DI 3 DI 2 FLN TX RX + - S BST RTS MOUNTING RAIL + - S TC0168R5 POWR TRMINATIONS DO LDS FLN TRMINATIONS
More informationUnit Vent Controller 0-10 V Output
Install llation Instruction ons Document No. 540-205 Rev. 2, January, 1999 Unit Vent Controller 0-10 V Output Produ oduct Description These instructions explain how to field install (pages 1 through 3)
More informationSiemens BACnet Programmable TEC Constant Volume
Technical Specification Sheet Document No. 149-852 September 24, 2014 Siemens BACnet Programmable TEC Constant Volume Returns from power failure without operator intervention. No calibration required,
More informationPXC Compact Unitary Equipment Controller (UEC)
Document No. 553-169 PXC Compact Unitary Equipment Controller (UEC) Product Description The PXC Unitary Equipment Controller (UEC) is an MS/TP device that can be configured as a programmable, stand-alone
More informationSiemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller
Technical Specification Sheet Document No. 149-851 September 24, 2014 Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller The Siemens BACnet PTEC Dual Duct Controller provides
More informationBACnet Terminal Box (VAV) Controller
Technical Specification Sheet May 30, 2012 BACnet Terminal Box (VAV) Controller Figure 1. BACnet Terminal Box Controller. The BACnet Terminal Box Controller (Figure 1) provides high performance Direct
More informationSiemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller
Technical Specification Sheet Document No. 149-834 August 23, 2010 Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller The Siemens BACnet PTEC VAV with Series Fan and
More informationLaunch Pad User Guide
Launch Pad User Guide 145-1005 Building Technologies 2017-06-30 Copyright Notice Cyber security disclaimer Copyright Notice Notice Document information is subject to change without notice by Siemens Industry,
More informationSiemens BACnet VAV Actuator
Technical Specification Sheet Document No. 149-481 May 30, 2012 Siemens BACnet VAV Actuator Setpoints and control parameters assigned and changed locally or remotely. Setpoints and control parameters stored
More informationSiemens BACnet Programmable TEC Unit Conditioner Controller
Technical Specification Sheet Document No. 149-831 September 24, 2014 Siemens BACnet Programmable TEC Unit Conditioner Controller Returns from power failure without operator intervention. No calibration
More informationoom Pressurization Con
Technical Specification Sheet Rev. 3, December, 1998 Room Pressurization Controllers equipment. This approach to room control includes the following features. Features gure 1. Roo oom Pressurization Con
More informationSiemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller
Technical Specification Sheet Document No. 149-831 August 12, 2011 Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller No calibration required, thereby reducing maintenance costs. PID
More informationSiemens BACnet Programmable TEC Unit Vent Controller
Technical Specification Sheet Document No. 149-833 August 12, 2011 Siemens BACnet Programmable TEC Unit Vent Controller The Siemens BACnet PTEC Unit Vent Controller provides high performance Direct Digital
More informationSiemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control
Technical Specification Sheet Document No. 149-844 August 12, 2011 Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control Returns from power failure without operator intervention.
More informationSiemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller
Technical Specification Sheet Document No. 149-851 August 12, 2011 Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller The Siemens BACnet PTEC Dual Duct Controller provides high
More informationApplication MC User Guide
Application MC User Guide Building Technologies Copyright Notice Cyber security disclaimer Copyright Notice Notice Document information is subject to change without notice by Companies, names, and various
More informationDual Duct Controller - One Air Velocity
Technical Specification Sheet Rev. 4, December, 1998 Dual Duct Controller - One Air Velocity Sensor gure 1. Dual Duct Con ontr troll ller One Air Velocity Sen ensor. The Dual Duct Controller (re 1) is
More informationOpenAir Electronic Damper Actuator GDE/GLB Rotary Non-spring Return
OpenAir Electronic Damper Actuator GDE/GLB Rotary Non-spring Return Document No. 9-67 EA678R a b e d c f a. Actuator b. Position indicator c. Mounting bracket d. Mounting screws e. 4 mm hex key f. Shaft
More informationOpen Processor with Square D Driver
Document No. 565-922 Open Processor with Square D Driver PRODUCT DESCRIPTION Each Open Processor (Figure 1) contains the main processor, memory, and communications circuitry for connecting APOGEE to another
More informationActuator Commissioning Tool
Document No. 129-287 Actuator Commissioning Tool Product Description The 985-047 Actuator Commissioning Tool provides a portable instrument for exercising, calibrating, and testing resistive, proportional
More informationOpen Processor with Carrier CCN DataLink Driver
Open Processor with Carrier CCN DataLink Driver Product Description Each Open Processor (Figure 1) contains the main processor, memory, and communications circuitry for connecting the APOGEE Automation
More informationBACnet Lab and Pressurized Room Controllers with Off-board Air Modules
Technical Specification Sheet Document No. 149-855 October 5, 2012 BACnet Lab and Pressurized Room Controllers with Off-board Air Modules Off-board Air Module Figure 1. Lab Controller Module. The OAM (Figure
More informationSiemens BACnet Programmable TEC Unit Vent Controller for Smoke Control
Technical Specification Sheet Document No. 149-841 August 12, 2011 Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control The Siemens BACnet PTEC Unit Vent Controller provides high performance
More informationXTM 1050 Replacement Parts Installation
XTM 1050 Replacement Parts Installation Instructions to replace or install: Power Supply Chassis Fan Fiber Card 10 Gb Interface Module WARNING! Do not open the XTM 1050 or try to replace or install any
More informationTEC Controller Extended I/O Application 2497 with Slave Mode Application Application Note Building Technologies
TEC Controller Extended I/O Application 2497 with Slave Mode Application 2489 Application Note 140-1074 Building Technologies Table of Contents Overview... 4 Hardware Inputs... 4 Hardware Outputs... 4
More informationActuating Terminal Equipment Controller (ATEC) VAV with Reheat. Start-up Procedures Building Technologies Restricted
Actuating Terminal Equipment Controller (ATEC) VAV with Reheat Start-up Procedures 140-1202 Building Technologies 2015-05-06 Restricted Table of Contents... 4 Verifying Power to the Controller... 4 Setting
More informationPowermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control
Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control Description Features Application The Powermite 599 MT Series SAS Electronic Valve Actuator requires a 24 Vac
More informationReplacing the Power Supply
APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools
More informationSQM5 Reversing Actuators, with Multiple Analog Control Input Signals
Document No. 9-4 January 8, 8 SQ5 Reversing Actuators, with ultiple Analog Control Input Signals Product Description Reversing actuator used to position flow control valves, butterfly valves, dampers,
More informationActuating Terminal Equipment Controller (ATEC) VAV with Reheat - Cooling and Heating, Application Application Note
Actuating Terminal Equipment Controller (ATEC) VAV with Reheat - Cooling and Heating, Application 2501 Application Note 140-1220 Building Technologies Table of Contents Overview... 4 Hardware Inputs...
More informationTALON Network Manager- 2 & 6 Express
Technical Specification Sheet October 30, 2010 TALON Network Manager- 2 & 6 Express Description The TALON Network Manager-2 & 6 Express (TNM-2 XPR and TNM-6 XPR) is an embedded controller/server platform
More informationBAC-9000 Series VAV Controller Installation Guide
BAC-9000 Series VAV Controller Installation Guide CONTENTS Introduction... 1 Set Drive Hub (45/60 ) Rotation Limit... 1 Mount Controller... 2 Connect Sensors and Equipment... 3 Connect (Optional) Pressure
More informationMS/TP Point Pickup Module Owner's Manual
MS/TP Point Pickup Module Owner's Manual 125-5065 Building Technologies Copyright Notice Copyright Notice Notice Document information is subject to change without notice by Siemens Industry, Inc. Companies,
More informationTECH/DATA SHEET. Application. Model Chart. Installation. slon-v1. slon-v2. slon VAV Controller
TECH/DATA SHEET s-v1 s-v2 s VAV Controller Application Solidyne s s-v1 and s-v2 VAV Controllers are interoperable MARK -compliant variable air volume controllers. These controllers provide pressure independent
More informationFree Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit
Document No. 155-324 Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit Description Features Application Product Number Room temperature controller for four-pipe fan coil units.
More informationRWD68U Universal Controller
Document No. 155-738 RWD68U Universal Controller Description Features Product Number The Universal Controller is intended for heating, air conditioning, ventilation and refrigeration in comfort control
More informationHP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions
HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.
More informationE1135C PDU and Pod Upgrade Procedure
E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support
More informationVAV Modular Assembly (VMA) 1410/1420
Installation Instructions Issue Date June 9, 2004 VAV Modular Assembly (VMA) 1410/1420 Application The Variable Air Volume (VAV) Modular Assembly (VMA) 1400 Series consists of configurable digital controllers.
More informationSED2 VFD NEMA Type 3R Bypass/Air Conditioner
SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications
More informationSQM5 Reversing Actuator with Analog Input Signal
Document o. 129-4 June 1, 25 SQ5 Reversing Actuator with Analog Input Signal Product Description Reversing actuator used to position flow control valves, butterfly valves, dampers, or any application requiring
More informationHIMatrix Safety-Related Controller Maintenance Manual
HIMatrix Safety-Related Controller Maintenance Manual HIMA Paul Hildebrandt GmbH + Co KG Industrial Automation Rev. 1.00 HI 800 455 E All HIMA products mentioned in this manual are protected by the HIMA
More informationPowermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control
Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control Document No. 55-34P25 EA 599-6 October 7, 28 EA57R Description Features Application Product Numbers The Powermite 599 MT Series
More informationBTU 4 & Sensors. Installation and Operation Manual
BTU 4 & Sensors Installation and Operation Manual Table of Contents Introduction... 1 Sensors... 1 BTO Outdoor Sensor... 1 BTI Indoor Sensor... 2 BTS Stack Sensor... 2 Installation... 3 BTU 4 Burk Temperature
More informationRDF Series Room Temperature Controllers
Document No. 19-49 RDF Series Room Temperature Controllers Product Description Room Temperature Controllers with LCD for twopipe (with and without an electrical heater) and fourpipe fan coil units. Installation
More informationBACnet Driver on the TC Series Platform
Technical Specification Sheet Document No. 127-1648T October 29, 2015 Systems Integration BACnet Driver on the TC Series Platform Figure 1: Typical BACnet Driver System Configuration with BACnet MS/TP
More informationCisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2
Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,
More informationSLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L)
SLX Series Document No. 997-1000 Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L) Free Programmable Controllers (SLX-PC-203, SLX-PC-300, SLX-PC-400, SLX-PC-500
More informationRack Installation Instructions
Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following: v Two
More informationON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)
(ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET TCY-BH-T-U Wall controller with sensor TDC-BH-T-U Duct controller with sensor SOA-Tn10 Outdoor temperature sensor (Optional) OVERVIEW For wall applications
More informationPS/IO Circuit Board Retrofit
S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....
More informationBTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual
BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors Installation and Operation Manual BTU-4D/BTU-4D-I Installation and Operation Manual Rev E Table of Contents Introduction... 1 TEMP OUTDOOR Sensor... 1
More information599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control
599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control Technical Instructions EA1021R1 Description The 599 SF Series electronic zone valve actuators, accepts 24 Vac, 120
More information1. Carefully unpack the um260 s shipping carton and check the contents for damage.
um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing
More informationINSTALL INSTRUCTIONS RSXMR-9886-P-48
INSTALL INSTRUCTIONS RSXMR-9886-P-48 Installation Instructions RSXMR-9886-P-48 (CEQ. 20194) INSTALL INSTRUCTIONS RSXMR-9886-P-48 Contents Section Description Page 1 Copyright 2 1.1 Disclaimer 2 1.2 Warnings
More informationService Bulletin. MiTek. RoofTracker Roof Truss Roller Press. Machinery Affected: Adding an Operator Platform. Machinery Division
MiTek Machinery Division Service Bulletin Machinery Affected: Document: Title: Applies To: RoofTracker Roof Truss Roller Press SB171 Adding an Operator Platform Frames 51 and Lower Copyright 2006 MiTek.
More informationTX-I/O Product Range. Description. Technical Specification Sheet Document No July 18, 2013
Technical Specification Sheet Document No. 149-476 July 18, 2013 TX-I/O Product Range TX-I/O is a range of I/O modules, with associated power and communication modules, for use within the APOGEE Automation
More informationUnitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000
Technical Specification Sheet Rev. 6, March, 2000 Unitary Controller The Unitary Controller can operate as an independent stand-alone controller, or can be connected to the APOGEE Automation System via
More informationM5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions
M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions Part No. 530-003244-01 Revision 1 27 July 2000 This document describes how to remove and replace the AC and DC power supplies,
More informationHP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.
HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see
More informationFirmware Revision 3.5 Release Notes
Firmware Revision Release Notes 588-584-3P5 Building Technologies Copyright Notice Copyright Notice Notice Document information is subject to change without notice by Siemens Industry, Inc. Companies,
More informationPart Name/Description Part Number Quantity
Part Name/Description Part Number Quantity Direct Command Kit 4100883 1 Installation Instructions 2006336 1 Hardware Kit Large Module 2001354-1 2 Cable Installation Kit 2000901-1 1 Quick Reference Card
More informationEXN4000 Storage Expansion Unit Installation and Setup Instructions
IBM System Storage EXN4000 Storage Expansion Unit Installation and Setup Instructions GC27-2079-02 IBM System Storage EXN4000 Storage Expansion Unit Installation and Setup Instructions GC27-2079-02 Notices
More informationTX-I/O Product Range. Features. Description. Technical Specification Sheet Document No January 24, 2007
Technical Specification Sheet Document No. 149-476 January 24, 2007 TX-I/O Product Range Description TX-I/O is a line of I/O modules with associated power and communication modules for use within the APOGEE
More informationPower Open Processor/Open Processor
Document No. 545-461 Power Open Processor/Open Processor CAUTION: The Power Open Processor/Open Processor MMI and MMI/Modem ports cannot be connected to a public telephone network without an authorized
More informationEAP110-Outdoor. Installation Guide. 300Mbps Wireless N Outdoor Access Point
EAP110-Outdoor Installation Guide 300Mbps Wireless N Outdoor Access Point Contents Overview 1 Typical Network Topology 4 Lightning and ESD Protection 5 Hardware Installation Mount EAP Connect Cables Power
More informationPowers TM Controls RL 243 MP Multi-Purpose Relay
Powers TM Controls Technical Instructions Document No. 155-042P25 RL 243-6 Description The Powers is a pneumatic auxiliary device designed to provide a variety of pneumatic control functions for the typical
More informationSmart Multivariable Transmitter (SMV 3000) Electronics Module Replacement Kit Instruction
Smart Multivariable Transmitter (SMV 3000) Electronics Module Replacement Kit Instruction Electronics Module (Part number 51404208 503, -513) Document Form: 34-SM-33-01 Effective: 09-01 Supersedes: 34-SM-33-01,
More informationHP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions
HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W
More informationBACnet VAV Actuator Start-up Guide IM 1040
BACnet VAV Actuator Start-up Guide IM 1040 Group: Controls Part Number: IM 1040 Date: 3/4/2010 Supersedes: New BACnet VAV Actuator--Electronic Output Start-up Procedures 2010 McQuay International Table
More informationHeat Containment System (HCS)
Heat Containment System (HCS) Revision Number 1 Wright Line LLC 160 Gold Star Boulevard Worcester, MA 01606 Tel: 800-225-7348 508-852-4300 Fax: 508-365-6178 www.wrightline.com info@wrightline.com All products
More informationMNL-V1RVx MNL-V2RVx. Application. Model Chart. TAC I/A Series MicroNet Variable Air Volume Controllers Installation Instructions
TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com MNL-V1RVx MNL-V2RVx TAC I/A Series MicroNet Variable Air Volume Controllers Installation Instructions Application TAC I/A Series
More informationRMB Peripheral Units Installation Guide
RMB Peripheral Units Installation Guide Part Number 65-000101 2011 by Kentrox, Inc. All rights reserved. Copyright 2011 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication
More informationEaton LCD Lift Flat Panel Display System. Installation Guide
Eaton LCD Lift Flat Panel Display System Eaton LCD Lift Flat Panel Display System Installation Guide Copyright 2011 Eaton Corporation, Worcester, MA, USA. All rights reserved. Information in this document
More informationEMC 10T "CE" Mechanical Upgrade Procedure
EMC 10T "CE" Mechanical Upgrade Procedure Kit Part Number: 009866-01 This procedure upgrades a non-ce compliant machine to the mechanical requirements of a CE compliant machine. Properly upgraded machines
More informationBACnet PTEC Controller Constant Volume - Cooling Only, Application Application Note Building Technologies
BACnet PTEC Controller Constant Volume - Cooling Only, Application 6660 Application Note 140-1107 Building Technologies Table of Contents Overview... 4 BACnet... 5 Hardware Inputs... 5 Room Unit Identification...
More informationIBM. Rack Installation Instructions
IBM Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following:
More informationInstallation Instructions Model ZAM-180
s Installation Instructions Model ZAM-80 Zone Amplifier Module 80W (500-035600 / S24235-B6-A5 (70V)) Installation Instructions for North America INTRODUCTION The Model ZAM-80 from Siemens Industry, Inc.
More informationMODEL SW6000 & SM6100 CENELEC INSTRUCTIONS
MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS Installation Manual 1180 METRIX Experience Value 8824 Fallbrook Dr. Houston, TX 77064, USA Tel: 1-281-940-1802 After Hours Technical Assistance: 1-713-702-8805
More informationThree Phase Residential Solution for Australia, System Design and Installation Guidelines
Three Phase Residential Solution for Australia, System Design and Installation Guidelines This document describes how to design and install SolarEdge three phase inverters for residential installations.
More informationAutoScan to MultiScan Replacement Kit
Instruction Sheet P/N AutoScan to MultiScan Replacement Kit WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other
More informationTX-I/O Product Range. Description. Technical Specification Sheet Document No February 20, 2018
Technical Specification Sheet Document No. 149-476 February 20, 2018 TX-I/O Product Range TX-I/O is a range of I/O modules, with associated power and communication modules, for use within the APOGEE Automation
More informationTECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2
document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com
More informationInstallation Instructions for Installing the Advanced Video Input Board in a D9032 Encoder
Installation Instructions for Installing the Advanced Video Input Board in a D9032 Encoder Overview Audience These installation instructions apply to trained Cisco service personnel who want to install
More informationTable of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION
Document 476092 User and Service Manual Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationJunos WebApp Secure 5.0 Hardware Guide
Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a
More informationPlasma Panel Replacement Guide DU-42PX12X
Plasma Panel Replacement Guide DU-42PX12X Panel Replacement: At this point, the panel has been determined to be defective and replacement is necessary. Upon receiving the replacement panel, it must be
More information599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control
599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control Technical Instructions Tuesday, August 18, 2009 EA1021R1 Description The 599 SF Series electronic zone valve actuators,
More information