Communication. Features. Device variant. Copyright 2017, Builder: , Time: 01:29:48

Size: px
Start display at page:

Download "Communication. Features. Device variant. Copyright 2017, Builder: , Time: 01:29:48"

Transcription

1 Version V2.2.9 Release date Copyright 217, Builder: , Time: 1:29:48 SM Vendor ID Device ID Vendor name Vendor text Vendor URL 31 / x136 - s: 1 54 / x1 x36 59 / x1fd - s: / x x1 xfd ifm electnic gmbh Communication IO-Link revision Bit rate Minimum cycle time SIO mode supported Features Block parametrization Data storage V1.1 COM2 5. ms Yes Yes Yes Device variant SM51 Magnetic-inductive flow meter, 5...9, G 2 Page 1

2 Pcess data (Pcess data input) Total bit length = 64 Bit offset Bit length Totalizer Quantity meter which continuously totals the volumetric flow since the last reset Float32T to l Flow Current flow (931) Err 92 to 93 (OL) to to -92 (UL) (-931) Err.1 Temperature Current temperature 2 14 (112) Err 1 to 11 (OL) -399 to to -4 (UL) (-52) Err.1 OUT2 Status depends on [OU2] BooleanT 1 (false) inactive (true) active OUT1 Status depends on [OU1] BooleanT (false) inactive (true) active Page 2

3 Page 3

4 Standard Command 2 wo (13) Restore Factory Settings (161) Reset [HI.F] and [LO.F] memory (162) Reset [LO.F] memory (163) Reset [HI.F] memory (164) Reset Totalizer (165) Reset [HI.T] and [LO.T] memory (166) Reset [LO.T] memory (167) Reset [HI.T] memory (176) Start simulation (177) Stop simulation (24) IO-Link 1.1 system test command 24, Event 8DFE appears (241) IO-Link 1.1 system test command 241, Event 8DFE disappears (242) IO-Link 1.1 system test command 242, Event 8DFF appears Page 4

5 Standard Command 2 wo (243) IO-Link 1.1 system test command 243, Event 8DFF disappears (255) Command without effect, for internal use only Device Locks 12 RecordT Data Storage Unlocked: Parameter are saved in IO-Link masters memory. Locked: Saving of parameters in the IO-Link master is not possible. [INFO] Concerning this parameter, IO-Link master and device have to be configured the same way. An activated DataStorage within the masters configuration, indicates the devices DataStorageLock to be 'Unlocked'. bitoffs 1 BooleanT 1 Bit (false) (false) Unlocked (true) Locked Local User Interface Unlocked: Parameter can be changed via the devices keys. Locked: Parameter changes via the devices keys are prevented bitoffs 3 BooleanT 1 Bit (false) (false) Unlocked (true) Locked Vendor of the vendor of the device. 16 max 19 ifm electnic gmbh Vendor Text Additional information of the devices vendor. 17 max 11 Page 5

6 Pduct 18 max 6 SM51 Pduct ID 19 max 6 SM51 Pduct Text 2 max 29 Magnetic- inductive flow meter Serial Number 21 max 11 Hardware Version 22 max 2 Firmware Version 23 max 3 Application Specific Tag A freely defined text can be assigned. 24 max 16 Detailed Device Status h SP1_FLOW Switch point 1 / Flow, [SP1] 7 must be greater than [rp1]. Please take into account the current [rp1] value. [SP1] will be refused if below [rp1] 18 1 to 9.1 rp1_flow Reset point 1 / Flow, [rp1] 71 must be smaller than [SP1]. Please take into account the current [SP1] value. [rp1] will be refused if above [SP1] to ImPS Pulse value 78 Float32T.1.1 to 9 1 l ImPR Pulse repetition active (= pulse output) or not active (= function preset meter) 79 (1) YES Page 6

7 ImPR Pulse repetition active (= pulse output) or not active (= function preset meter) 79 (1) YES (1) YES () no FEP Frequency output of the end point of the flow value to 9.1 FrEP Frequency End Point. Frequency at the Flow End Point to 1.1 khz OU1 Output configuration [OUT 1] 84 (3) Hno / Hysteresis fct normally open (3) Hno / Hysteresis fct normally open (4) Hnc / Hysteresis fct normally closed (5) Fno / Window fct normally open (6) Fnc / Window fct normally closed (9) ImP / Impulse output (12) dou / Diagnostic output (17) FRQ / Frequency output OU2 Output configuration [OUT 2] 85 (1) I / Analog signal 4 2 ma (1) I / Analog signal 4 2 ma Page 7

8 OU2 Output configuration [OUT 2] 85 (1) I / Analog signal 4 2 ma (2) U / Analog signal...1 V (3) Hno / Hysteresis fct normally open (4) Hnc / Hysteresis fct normally closed (5) Fno / Window fct normally open (6) Fnc / Window fct normally closed (12) dou / Diagnostic output (14) In.D / Digital input SP2_FLOW Switch point 2 / Flow, [SP2] 86 must be greater than [rp2]. Please take into account the current [rp2] value. [SP2] will be refused if below [rp2] 36 1 to 9.1 rp2_flow Reset point 2 / Flow, [rp2] 87 must be smaller than [SP2]. Please take into account the current [SP2] value. [rp2] will be refused if above [SP2] to SP2_TEMP Switch point 2 / Temperature, 88 [SP2] must be greater than [rp2]. Please take into account the current [rp2] value. [SP2] will be refused if below [rp2] to 8.1 Page 8

9 rp2_temp Reset point 2 / Temperature, [rp2] must be smaller than [SP2]. Please take into account the current [SP2] value. [rp2] will be refused if above [SP2] to ASP2_FLOW Analogue start point 2 / Flow. [ASP2] must be smaller than [AEP2]. Please take into account the current [AEP2]. For info on the minimum hysteresis [AEP2]-[ASP2] please refer to the operating instructions 9 to 72.1 AEP2_FLOW Analogue end point 2 / Flow. 91 [AEP2] must be greater than [ASP2]. Please take into account the current [ASP2]. For info on the min hysteresis [AEP2]-[ASP2] please refer to the operating instructions 9 18 to 9.1 ASP2_TEMP Analogue start point 2 / 92 Temperature. [ASP2] must be smaller than [AEP2]. Please take into account the current [AEP2]. For info on the minimum hysteresis [AEP2]-[ASP2] please refer to the operating instructions -2-2 to 6.1 AEP2_TEMP Analogue end point 2 / 93 Temperature. [AEP2] must be greater than [ASP2]. Please take into account the current [ASP2]. For info on the min 8 to 8.1 Page 9

10 hysteresis [AEP2]-[ASP2] please refer to the operating instructions DIn2 Configuration of digital input (Pin 2) 94 (2) +EDG () HiGH (1) LoW (2) +EDG (3) -EDG rto Meter reset mode 99 RecordT [OFF] = Manual reset / [Time] = Time contlled reset bitoffs 15 BooleanT 1 Bit (true) OFF (false) Time (true) OFF Meter reset time: coarse adjustment bitoffs 8 3 Bit (1) hours (1) hours (2) days (4) weeks Meter reset time: fine adjustment. Allowed max values for [Time] are 23 hours or 6 days or 8 weeks bitoffs (1) 1 (1) 1 (2) 2 (3) 3 (4) 4 (5) 5 (6) 6 (7) 7 (8) 8 (9) 9 (1) 1 (11) 11 (12) 12 (13) 13 (14) 14 Page 1

11 rto Meter reset mode 99 RecordT (15) 15 (16) 16 (17) 17 (18) 18 (19) 19 (2) 2 (21) 21 (22) 22 (23) 23 FOU1 [OUT 1] behaviour in case of fault 11 (4) OFF (1) OU (2) On (4) OFF FOU2 [OUT 2] behaviour in case of fault 12 (4) OFF (1) OU (2) On (4) OFF dst Delay Startup 13 to 5.1 s P-n Output polarity for the switching outputs 14 () PnP () PnP (1) npn dap Damping of the measured signal 15 6 to 5.1 s Page 11

12 dis Display settings 16 RecordT Display On / OFF bitoffs 7 BooleanT 1 Bit (false) On (false) On (true) OFF Display orientation bitoffs 6 BooleanT 1 Bit (false) Not tated (false) Not tated (true) Rotated 18 Update rate bitoffs 6 Bit (2) d2 / medium (1) d1 / fast (2) d2 / medium (4) d3 / slow Uni Selection of the physical unit 17 () () (1) m³/h SELd Selection of measurement on the sensor display 18 RecordT Displayed measurement bitoffs 15 Bit (1) FLOW (1) FLOW (2) TEMP (4) TOTL SEL2 Selection of the measurand for the evaluation via [OUT 2] 11 (1) FLOW (1) FLOW (2) TEMP LFC Low flow cutoff to 15.1 FP Totalizer counting rule 112 () -+ () -+ (1) + Fdir Preferred direction of flow 114 () + () + Page 12

13 Fdir Preferred direction of flow 114 () + (1) - HI.F Maximum memory value for flow 118 () (931) Err.1 92 to 93 (OL) to to -92 (UL) (-931) Err LO.F Minimum memory value for flow 119 () (931) Err.1 92 to 93 (OL) to to -92 (UL) (-931) Err HI.T Maximum memory value for temperature 12 () (112) Err.1 1 to 11 (OL) -399 to to -4 (UL) (-52) Err LO.T Minimum memory value for temperature 121 () (112) Err.1 Page 13

14 LO.T Minimum memory value for temperature 121 () 1 to 11 (OL) to to -4 (UL) (-52) Err EP.On Empty pipe detection On / Off 124 () OFF () OFF (1) On EP.SP Empty pipe detection switch point to 15 1 % dep.e Delay of the empty pipe detection when the switch point [EP.SP] is underrun 127 to 3.1 s dep.f Delay of the empty pipe detection when the switch point [EP.SP] is exceeded to 3.1 s S.FLW Simulation of flow 131 (18).1-92 to to -921 (UL) 921 to 93 (OL) (931) Err (144) SENS S.TMP Simulation of temperature 132 (2).1-4 to 1-5 to -42 (UL) Page 14

15 S.TMP Simulation of temperature 132 (2) 12 to 11 (OL) (112) Err.1 S.Tim Simulation duration 133 (2) 3 min () 1 min (1) 2 min (2) 3 min (3) 4 min (4) 5 min (5) 1 min (6) 15 min (7) 2 min (8) 3 min (9) 45 min (1) 6 min S.On Simulation state 134 () OFF (1) On () OFF Loc [Loc] locks the local user interface to prevent unintentional changes, [Loc] is resettable at the device 138 (1) uloc () Loc (1) uloc TOTL_M Consumed quantity before the last reset 148 Float32T to l Page 15

16 EP.Pr Empty pipe detection pcess value 29-5 to 15 1 % Events Code Type 348 d / 77 1 h Short circuit Err Check installation d / 8C 1 h Pcess variable range over-run Warning Pcess data uncertain. [INFO] This Event will not be transmitted via IO-Link Event mechanism. It is only available by reading 37 (Detailed Device Status) or 545 (BitCoded_ActiveEvents) d / 8C 2 h Measurement range over-run Err Check application d / 8C 3 h Pcess variable range under-run Warning Pcess data uncertain. [INFO] This Event will not be transmitted via IO-Link Event mechanism. It is only available by reading 37 (Detailed Device Status) or 545 (BitCoded_ActiveEvents) 3633 d / 8C C1 h Measuring pipe not sufficiantly filled. Too low conductivity of medium. Warning Please check your application 3634 d / 8C C2 h Measurement data acquisition failure. Err Replace device 3635 d / 8C C3 h Display function failure Warning Replace device 3635 d / 8D FE h Test Event 1 Warning Event appears by setting index 2 to value 24, Event disappears by setting index 2 to value d / 8D FF h Test Event 2 Warning Event appears by setting index 2 to value 242, Event disappears by setting index 2 to value 243 Err types Err code d / 8 h d / 8 11 h d / 8 12 h 328 d / 8 2 h 3283 d / 8 23 h Device application err - no details not available not available Service temporarily not available denied Service has been refused by the device application and no detailed information of the incident is available occurs to a not existing index occurs to a not existing subindex Parameter is not accessible due to the current state of the device application Write access on a read-only parameter Page 16

17 Err types Err code d / 8 3 h d / 8 33 h 3282 d / 8 34 h d / 8 35 h d / 8 36 h d / 8 4 h d / 8 41 h d / 8 82 h Parameter value out of range Parameter length overrun Parameter length underrun Function not available Function temporarily unavailable Invalid parameter set Inconsistent parameter set Application not ready Written parameter value is outside its permitted value range Written parameter length is above its predefined length Written parameter length is below its predefined length Written command is not supported by the device application Written command is not available due to the current state of the device application Written single parameter collides with other actual parameter settings Parameter inconsistencies were found at the end of block parameter transfer, device plausibility check failed Read or write service is refused due to a temporarily unavailable application Page 17

Communication. Features. Device variant. Copyright 2016, Builder: , Time: 04:59:44

Communication. Features. Device variant. Copyright 2016, Builder: , Time: 04:59:44 Version V1.3.25.557559 Release date 216-11-3 Copyright 216, Builder: 3.1.1.2, Time: 4:59:44 SM Vendor ID Device ID Vendor name Vendor text Vendor URL 31 / x136 - s: 1 54 / x1 x36 575 / x23f - s: 2 63 /

More information

Communication. Features. Device variant. Copyright 2015, Builder: , Time: 09:23:27

Communication. Features. Device variant. Copyright 2015, Builder: , Time: 09:23:27 Version V.3.3. Release date 25--4 Copyright 25, Builder: 2.5.2.5, Time: 9:23:27 SB Vendor ID Device ID Vendor name Vendor text Vendor URL 3 / x36 - s: 54 / x x36 56 / x23 - s: 2 49 / x x2 x3 ifm electnic

More information

PN7. Communication. Features. Device variant. Copyright 2015, Builder: , Time: 04:31:57

PN7. Communication. Features. Device variant. Copyright 2015, Builder: , Time: 04:31:57 Version V2.2.4 Release date 215-7-2 Copyright 215, Builder: 2.3.1.1, Time: 4:31:57 PN7 Vendor ID Device ID Vendor name Vendor text Vendor URL 31 / x136 - Bytes: 1 54 / x1 x36 311 / x137 - Bytes: 1 55 /

More information

TV7. Communication. Features. Device variant. Copyright 2017, Builder: , Time: 05:34:05

TV7. Communication. Features. Device variant. Copyright 2017, Builder: , Time: 05:34:05 Version V1.6 Release date 217-3-8 Copyright 217, Builder: 3.3.2.2, Time: 5:34:5 TV7 Vendor ID Device ID Vendor name Vendor text Vendor URL 31 / x136 - s: 1 54 / x1 x36 733 / x2dd - s: 2 221 / x x2 xdd

More information

Communication. Features. Device variant. Copyright 2017, Builder: , Time: 02:39:41

Communication. Features. Device variant. Copyright 2017, Builder: , Time: 02:39:41 Version V1.3.35.621612 Release date 217-7-6 Copyright 217, Builder: 3.3.2.4, Time: 2:39:41 LK Vendor ID Device ID Vendor name Vendor text Vendor URL 31 / x136 - s: 1 54 / x1 x36 652 / x28c - s: 2 14 /

More information

TAD_3T. Communication. Features. Device variant. Copyright 2017, Builder: , Time: 09:44:44

TAD_3T. Communication. Features. Device variant. Copyright 2017, Builder: , Time: 09:44:44 Version V1..7 Release date 217-5-5 Copyright 217, Builder: 2.5.4.1, Time: 9:44:44 TAD_3T Vendor ID Device ID Vendor name Vendor text Vendor URL 31 / x136 - s: 1 54 / x1 x36 558 / x22e - s: 2 46 / x x2

More information

Communication. Features. Device variant. Copyright 2017, Builder: , Time: 10:07:14

Communication. Features. Device variant. Copyright 2017, Builder: , Time: 10:07:14 Version V.3.4.3 Release date 27-2-27 Copyright 27, Builder: 3.3.2., Time: :7:4 UG Vendor ID Device ID Vendor name Vendor text Vendor URL 3 / x36 - s: 54 / x x36 7 / x2bd - s: 2 89 / x x2 xbd ifm electnic

More information

Communication. Features. Device variant. Copyright 2017, Builder: , Time: 06:40:09

Communication. Features. Device variant. Copyright 2017, Builder: , Time: 06:40:09 Version V.3.4. Release date 27--23 Copyright 27, Builder: 4..., Time: 6:4:9 DI Vendor ID Device ID Vendor name Vendor text Vendor URL 3 / x36 - s: 54 / x x36 9 / x38f - s: 3 43 / x x3 x8f ifm electnic

More information

Communication. Features. Device variant. Copyright 2018, Builder: , Time: 02:11:09

Communication. Features. Device variant. Copyright 2018, Builder: , Time: 02:11:09 Version V1.3.14.8 Release date 218-3-19 Copyright 218, Builder: 4.1.3.3, Time: 2:11:9 O6 Vendor ID Device ID Vendor name Vendor text Vendor URL 31 / x136 - s: 1 54 / x1 x36 526 / x2e - s: 2 14 / x x2 xe

More information

PV7. Communication. Features. Device variant. Copyright 2016, Builder: , Time: 02:58:01

PV7. Communication. Features. Device variant. Copyright 2016, Builder: , Time: 02:58:01 Verion V1.3.23.538632 Releae date 216-8-29 Copyright 216, Builder: 3..3.3, Time: 2:58:1 PV7 Vendor ID Device ID Vendor name Vendor text Vendor URL 31 / x136 - : 1 54 / x1 x36 713 / x2c9 - : 2 21 / x x2

More information

PN2. Copyright 2013, ifm electronic gmbh. Vendor ID / 0x Bytes: / 0x00 0x00 0x49

PN2. Copyright 2013, ifm electronic gmbh. Vendor ID / 0x Bytes: / 0x00 0x00 0x49 Verion: V.4. Releae Date: 23-2-4 Copyright 23, ifm electnic gmbh PN2 Vendor ID Vendor Vendor Text Vendor URL Device ID 3 / x36 - Byte: 54 / x x36 ifm electnic gmbh www.ifm.com http://www.ifm.com/ifmgb/web/io-link_down.htm

More information

Operating instructions Mechatronic flow sensor SBY2xx SBG2xx SBN2xx SB0524

Operating instructions Mechatronic flow sensor SBY2xx SBG2xx SBN2xx SB0524 Operating instructions Mechatronic flow sensor SBY2xx SBG2xx SBN2xx SB0524 UK 80256992 / 00 11 / 2016 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 3 Functions and features...5

More information

Page 1. Version: V Release date: Copyright / 0x0136 Bytes: / 0x01 0x / 0x00037C Bytes: C / 0x00 0x3 0x7C

Page 1. Version: V Release date: Copyright / 0x0136 Bytes: / 0x01 0x / 0x00037C Bytes: C / 0x00 0x3 0x7C Version: V1.0.19 Release date: 2017-09-22 Copyright 2017 DF Vendor ID Device ID Vendor name Vendor text Vendor URL 310 / 0x0136 Bytes: 01 36 / 0x01 0x36 892 / 0x00037C Bytes: 00 03 7C / 0x00 0x3 0x7C ifm

More information

Operating instructions Electronic temperature sensor TN /00 04/2011

Operating instructions Electronic temperature sensor TN /00 04/2011 Operating instructions Electronic temperature sensor TN7531 UK 704772/00 04/2011 Contents 1 Preliminary note3 1.1 ymbols used 3 2 afety instructions 3 3 Functions and features 4 4 Function 4 4.1 Communication,

More information

Operating instructions Electronic temperature sensor TN7511

Operating instructions Electronic temperature sensor TN7511 Operating instructions Electronic temperature sensor TN7511 80231575 / 00 11 / 2016 Contents 1 Safety instructions...3 2 Functions and features...3 3 Function...3 3.1 Switching function...4 3.2 Display

More information

Operating instructions Flow sensors SAxx04 SAxx14

Operating instructions Flow sensors SAxx04 SAxx14 Operating instructions Flow sensors SAxx04 SAxx14 UK 80261065 / 00 05 / 2018 Contents 1 Preliminary note...3 2 Safety instructions...4 3 Functions and features...4 4 Function...5 4.1 Operating modes (ModE)...5

More information

Operating instructions Control monitor for temperature sensors TR /00 04/2011

Operating instructions Control monitor for temperature sensors TR /00 04/2011 Operating instructions Control monitor for temperature sensors TR7432 704773/00 04/20 Contents Preliminary note3. ymbols used 3 2 afety instructions 3 3 Functions and features 4 4 Function 4 4. Communication,

More information

SM9000. Made in Germany

SM9000. Made in Germany Made in Germany Product characteristics Magnetic-inductive flow meter Connector Process connection: G2 flat seal connection to pipe by means of an adapter Function programmable Totaliser function Empty

More information

Operating instructions Control monitor for temperature sensors TR7439

Operating instructions Control monitor for temperature sensors TR7439 Operating instructions Control monitor for temperature sensors TR7439 80231577 / 00 11 / 2016 Contents 1 Safety instructions...3 2 Functions and features...3 3 Function...4 3.1 Switching function...4 3.2

More information

Operating instructions Electronic pressure sensor. PN2xxx / / 2015

Operating instructions Electronic pressure sensor. PN2xxx / / 2015 Operating instructions Electronic pressure sensor PN2xxx UK 80227599 / 00 05 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 3 Functions and features...4 3.1 Applications...5

More information

Operating instructions Electronic pressure sensor. PN22xx PN26xx / / 2015

Operating instructions Electronic pressure sensor. PN22xx PN26xx / / 2015 Operating instructions Electronic pressure sensor UK PN22xx PN26xx 80229687 / 00 05 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 3 Functions and features...4 3.1

More information

Operating instructions Pressure sensor. PN70xx / / 2012

Operating instructions Pressure sensor. PN70xx / / 2012 Operating instructions Pressure sensor PN70xx 706136 / 00 01 / 2012 Contents 1 Preliminary note...3 1.1 ymbols used...3 2 afety instructions...3 3 Functions and features...4 4 Function...5 4.1 Communication,

More information

Operating instructions Electronic digital pressure sensor EPS25-XXXX-1001

Operating instructions Electronic digital pressure sensor EPS25-XXXX-1001 Operating instructions Electronic digital pressure sensor EPS25-XXXX-00 80254563 / 00 06 / 206 AutomationDirect 3505 HutchinsonRoad Cumming, GA 30040 Contents Preliminary note...4. Symbols used...4 2 Safety

More information

Operating instructions Vortex flow meter. SVxxx / / 2015

Operating instructions Vortex flow meter. SVxxx / / 2015 Operating instructions Vortex flow meter SVxxx4 80226711 / 00 06 / 2015 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...3 3 Functions and features...4

More information

Operating instructions Pressure sensor. PN50xx / / 2010

Operating instructions Pressure sensor. PN50xx / / 2010 Operating instructions Pressure sensor PN50xx 704789 / 00 05 / 2010 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 4 Function...5 4.1 Processing

More information

Operating instructions Electronic pressure sensor PI22xx PI23xx

Operating instructions Electronic pressure sensor PI22xx PI23xx Operating instructions Electronic pressure sensor PIxx PI3xx UK 8000957 / 0 07 / 08 Contents Preliminary note...4. ymbols used...4 afety instructions...4 3 Functions and features...5 3. Applications...5

More information

Operating instructions Pressure sensor. PN78xx / / 2010

Operating instructions Pressure sensor. PN78xx / / 2010 Operating instructions Pressure sensor PN78xx UK 704788 / 00 05 / 2010 Contents 1 Preliminary note3 1.1 Symbols used 3 2 Safety instructions 3 3 Functions and features 4 4 Function 5 4.1 Processing of

More information

Operating instructions Optical distance sensor O1D / / 2012

Operating instructions Optical distance sensor O1D / / 2012 Operating instructions Optical distance sensor O1D106 UK 704204 / 01 08 / 2012 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...4 3 Functions and

More information

Operating instructions Optical distance sensor O1D / / 2008

Operating instructions Optical distance sensor O1D / / 2008 Operating instructions Optical distance sensor O1D155 UK 704391 / 01 11 / 2008 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 3 Functions and features...5 3.1 Applications...5

More information

Operating instructions Electronic pressure sensor PN7xxx

Operating instructions Electronic pressure sensor PN7xxx Operating instructions Electronic pressure sensor PN7xxx 8000579 / 00 08 / 208 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...4 3 Functions and features...5 3. Applications...5

More information

Operating instructions Electronic pressure sensor PI28xx

Operating instructions Electronic pressure sensor PI28xx Operating instructions Electronic pressure sensor PI28xx UK 80260760 / 00 12 / 2016 Contents 1 Preliminary note...4 1.1 ymbols used...4 2 afety instructions...4 3 Functions and features...5 3.1 Applications...5

More information

Operating instructions Electronic pressure sensor. PI22xx PI23xx / / 2013

Operating instructions Electronic pressure sensor. PI22xx PI23xx / / 2013 Operating instructions Electronic pressure sensor UK PIxx PI3xx 706333 / 00 03 / 03 Contents Preliminary note...4. ymbols used...4 afety instructions...4 3 Functions and features...4 3. Applications...4

More information

Operating instructions Electronic pressure sensor. PN72xx PN73xx PN76xx / / 2016

Operating instructions Electronic pressure sensor. PN72xx PN73xx PN76xx / / 2016 Operating instructions Electronic pressure sensor PN72xx PN73xx PN76xx 8002464 / 00 07 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...4 3 Functions and features...5 3. Applications...5

More information

Operating instructions Pressure sensor. PN70xx / / 2010

Operating instructions Pressure sensor. PN70xx / / 2010 Operating instructions Pressure sensor PN70xx 704917 / 00 08 / 2010 Contents 1 Preliminary note 3 1.1 ymbols used 3 2 afety instructions 3 3 Functions and features 4 4 Function 5 4.1 Processing of the

More information

Operating instructions Pressure sensor. PE30xx / / 2010

Operating instructions Pressure sensor. PE30xx / / 2010 Operating instructions Pressure sensor PE30xx UK 704884 / 00 08 / 2010 Contents 1 Preliminary note3 1. ymbols used 3 2 afety instructions 3 3 Functions and features 4 4 Function 5 4.1 Processing of the

More information

SM9000. Magnetic-inductive flow meter. Made in Germany

SM9000. Magnetic-inductive flow meter. Made in Germany Made in Germany Application Application totaliser function; empty pipe detection; for industrial applications Installation connection to pipe by means of an adapter Media conductive liquids; water; hydrous

More information

Operating instructions Combined pressure sensor. PN22xx / / 2010

Operating instructions Combined pressure sensor. PN22xx / / 2010 Operating instructions Combined pressure sensor PN22xx UK 704829 / 00 08 / 2010 Contents 1 Preliminary note 3 1.1 ymbols used 3 2 afety instructions 3 3 Function and features 4 4 Function 5 4.1 Communication,

More information

Operating instructions Encoder PerformanceLine. RxP5xx /00 04/2018

Operating instructions Encoder PerformanceLine. RxP5xx /00 04/2018 Operating instructions Encoder PerformanceLine RxP5xx UK 706393/00 04/208 Contents Preliminary note...4. Notes on this document...4.2 Symbols used...4 2 Safety instructions...4 2. General...4 2.2 Installation

More information

Object dictionary MLG-2

Object dictionary MLG-2 8021587 TECHNICAL INFORMATION Object dictionary MLG-2 Prime Englisch Physical Layer SIO Mode yes Min. Cycle Time 6 ms Baudrate COM 2 (38 kbit/s) Process Data Length 6 IODD Version V1.00 supported IO-Link

More information

Device manual Inclination sensor 2 axes. JN2201 Firmware /00 04/2016

Device manual Inclination sensor 2 axes. JN2201 Firmware /00 04/2016 Device manual Inclination sensor 2 axes JN2201 Firmware 1.0 80237499/00 04/2016 Content 1 Preliminary note................................................. 4 1.1 Symbols used...............................................

More information

Operating instructions Electronic level sensor LK10xx LK70xx

Operating instructions Electronic level sensor LK10xx LK70xx Operating instructions Electronic level sensor LK10xx LK70xx 80264293 / 01 11 / 2018 Contents 1 Preliminary note...4 1.1 ymbols used...4 2 afety instructions...4 3 Functions and features...5 3.1 Application

More information

Object dictionary MLG-2

Object dictionary MLG-2 8021466 TECHNICAL INFORMATION Object dictionary MLG-2 COM3 1. Physical Layer SIO Mode yes Min. Cycle Time 3 ms Baudrate COM 3 (230.4 kbit/s) Process Data Length PD In (from Device to Master) 32 Byte In

More information

IO-Link Data Reference Guide: LTF Series

IO-Link Data Reference Guide: LTF Series IO-Link Map This document refers to the following IODD file: Banner_Engineering-LTF12K-20170216-IODD1.1.XML. The IODD file and support files can be found on www.bannerengineering.com under the download

More information

Your Global Automation Partner. Uprox IO-Link Inductive Factor 1 Sensors with IO-Link

Your Global Automation Partner. Uprox IO-Link Inductive Factor 1 Sensors with IO-Link Your Global Automation Partner Uprox IO-Link Inductive Factor 1 Sensors with IO-Link Inductive Factor 1 Sensors with IO-Link With the release of our new Uprox IO-Link sensors, Turck s Factor 1 sensor offering

More information

Operating instructions Electronic pressure sensor. PF295x /00 07/2016

Operating instructions Electronic pressure sensor. PF295x /00 07/2016 Operating instructions Electronic pressure sensor PF295x 706068/00 07/206 Contents Preliminary note...3. ymbols used...3 2 afety instructions...3 3 Functions and features...4 3. Applications...4 4 Function...4

More information

IO-Link Data Reference Guide: LTF Series

IO-Link Data Reference Guide: LTF Series IO-Link Map This document refers to the following IODD file: Banner_Engineering-LTF12K-20170216-IODD1.1.XML. The IODD file and support files can be found on www.bannerengineering.com under the download

More information

Operating instructions Electronic level sensor LK81xx

Operating instructions Electronic level sensor LK81xx Operating instructions Electronic level sensor LK81xx UK 80264351 / 00 06 / 2017 Contents 1 Preliminary note...4 1.1 ymbols used...4 2 afety instructions...4 3 Functions and features...5 3.1 Applications...5

More information

Manual pressure sensors DW35311x DW36311x

Manual pressure sensors DW35311x DW36311x manual pressure sensor Seite 1 Manual pressure sensors DW35311x DW36311x Seite 2 manual pressure sensor table of contents Safety instructions page 3 Controls and indicating elements page 4 Description

More information

Operating instructions Photoelectric distance sensor OGD592 OGD593

Operating instructions Photoelectric distance sensor OGD592 OGD593 Operating instructions Photoelectric distance sensor OGD592 OGD593 UK 80272871 / 01 10 / 2018 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warnings used...4 2 Safety instructions...4 3 Functions

More information

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions Pressure switch Type HEDE10.../1/ RE 30276-B/10.10 Replaces: 06.10 Operating instructions 2/20 Bosch Rexroth AG HEDE10.../1/ RE 30276-B/10.10 Contents 1 Overview of menu...3 2 Safety note... 4 3 Operating

More information

Pressure switch type DG 51 E

Pressure switch type DG 51 E Pressure switch type DG 51 E Product documentation Operating pressure pmax: 600 bar D 5440 E/2 05-2017-1.0 by HAWE Hydraulik SE. The reproduction and distribution of this document as well as the use and

More information

Operating instructions Memory plug E /02 11/2011

Operating instructions Memory plug E /02 11/2011 Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5

More information

IO-Link Data Reference Guide: DF-G2

IO-Link Data Reference Guide: DF-G2 IO-Link Data Map This document refers to the following IODD file: Banner_Engineering-DF-G2-20170222-IODD1.1.xm. The IODD file and support files can be found on www.bannerengineering.com under the download

More information

Additional instructions. Programming of D-10-9/D Pressure transmitter with CANopen Interface D-11-9 D-10-9

Additional instructions. Programming of D-10-9/D Pressure transmitter with CANopen Interface D-11-9 D-10-9 Additional instructions Pgramming of D-10-9/D-11-9 Pressure transmitter with CApen Interface D-11-9 D-10-9 This instruction only contains additional information about the pgramming of D-10-9/D-11-9 CApen

More information

IO-Link Data Reference Guide: LM Series

IO-Link Data Reference Guide: LM Series IO-Link Map This document refers to the following IODD file: Banner_Engineering-LM-20180423-IODD1.1.XML. The IODD file and support files can be found on www.bannerengineering.com under the download section

More information

IO-Link parameter description

IO-Link parameter description Application Note IO-Link parameter description A brief explanation of the contents - identification - parameter and commands - block parameterization - teach-in - process data - using different pressure

More information

IO-Link parameter description

IO-Link parameter description Application Note IO-Link parameter description A brief explanation of the contents - identification - parameter and commands - block parameterization - teach-in - process data - using different pressure

More information

AG25, AG26. User manual 225/18

AG25, AG26. User manual 225/18 AG25, AG26 Actuator with User manual interface 225/18 Table of contents 1 General Information... 9 1.1 Documentation...9 2 Displays and operating elements... 9 2.1 General Information...9 2.2 Displays...9

More information

Operating instructions Electronic pressure sensor. PI109x / / 2010

Operating instructions Electronic pressure sensor. PI109x / / 2010 Operating instructions Electronic pressure sensor PI109x 704066 / 01 09 / 2010 Contents 1 Preliminary note 3 1.1 ymbols used 3 2 afety instructions 3 3 Functions and features 4 3.1 Applications 4 4 Function

More information

Ultrasonic sensors Discrete output Analog output

Ultrasonic sensors Discrete output Analog output Analog output General information Switch or analog outputs Sensing distances up to 6m Stainless steel housing Quick disconnect Index Discrete.... Analog....6 Technical data....8 AC 00 0/98 ULTRASONIC :

More information

Optical laser distance sensors. Dimensioned drawing

Optical laser distance sensors. Dimensioned drawing Optical laser distance sensors Dimensioned drawing We reserve the right to make changes DS_ODSL96BMLTOFS12_en_50117984-01.fm en 03-2013/01 50117984-01 18-30 V DC 0.3 10m Measurement range up to 10000mm

More information

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide BNI IOL322E12 IOLink 1.1 sensor/actuator hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL322E12 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions

More information

Operating instructions. Monitor FD / / 2013

Operating instructions. Monitor FD / / 2013 Operating instructions Monitor FD-1 UK 7390956 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

IO-Link Data Reference Guide: Q4X Sensor

IO-Link Data Reference Guide: Q4X Sensor IO-Link Map This document refers to the following IODD file: Banner_Engineering-Q4X-20150313-IODD1.1.xml for 100/110 mm and 300/310 mm models, and Banner_Engineering-Q4X-600mm-20161205-IODD1.1.xml for

More information

IO-Link parameter description

IO-Link parameter description Application Note IO-Link parameter description A brief explanation of the contents - identification - parameter and commands - block parameterization - teach-in - process data - using different pressure

More information

OPT2015. High-performance distance sensor. Operating Instructions

OPT2015. High-performance distance sensor. Operating Instructions OPT2015 High-performance distance sensor Operating Instructions 23.07.2013 2 Index 1. Proper Use 4 2. Safety Precautions 4 2.1. Safety Precautions 4 2.2. Laser/LED warning 4 3. EC Declaration of Conformity

More information

Optical distance sensors. Dimensioned drawing

Optical distance sensors. Dimensioned drawing Optical distance sensors Dimensioned drawing We reserve the right to make changes DS_ODS10L1_25M8L_en_50129321.fm en 04-2016/08 50129321 100 25000mm Measurement range up to 25000mm on HighGain foil Analog

More information

Operating instructions Binary level sensor LMC / / 2014

Operating instructions Binary level sensor LMC / / 2014 Operating instructions Binary level sensor LMC502 80224249 / 00 12 / 2014 Content 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...3 3.1 Applications...3

More information

Position transmitter SDAT-MHS e [ ]

Position transmitter SDAT-MHS e [ ] Position transmitter SDAT-MHS en Manual 8068247 1612e [8068249] Translation of the original instructions SDAT-MHS This documentation refers to the following version: From Revision R04. Identification of

More information

OFP401P0189. Color Sensor. Operating Instructions

OFP401P0189. Color Sensor. Operating Instructions OFP401P0189 Color Sensor Operating Instructions Last update: 23 May 2013 2 Table of contents 1. Proper Use 4 2. Safety Precautions 4 3. EC Declaration of Conformity 4 4. Technical Data 5 4.1. Connection

More information

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing ADVANCED ultrasonic sensors with 2 switching outputs Dimensioned drawing en 4-214/12 5124879 25 4mm 15 13mm 15-3 V DC We reserve the right to make changes DS_HTU418BX3LT4_en_5124879.fm Function largely

More information

OPT2011. High-performance distance sensor. Operating Instructions

OPT2011. High-performance distance sensor. Operating Instructions OPT2011 High-performance distance sensor Operating Instructions Status: 15/07/2013 2 Table of Contents 1. Use for Intended Purpose 4 2. Safety Precautions 4 2.1. Safety Precautions 4 2.2. Laser/LED warning

More information

Operating instructions Optical distance sensor. O5D15x / / 2014

Operating instructions Optical distance sensor. O5D15x / / 2014 Operating instructions Optical distance sensor O5D15x 706307 / 01 08 / 2014 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4

More information

OPT2041. Fiber Optic Cable Sensor. Operating Instructions. Available as PDF only Status:

OPT2041. Fiber Optic Cable Sensor. Operating Instructions. Available as PDF only Status: OPT2041 Fiber Optic Cable Sensor Operating Instructions Available as PDF only Status: 18.06.2018 www.wenglor.com Index 1. Proper Use 3 2. Safety Precautions 3 3. General Information Regarding the Device

More information

BNI IOL A027 BNI IOL A027

BNI IOL A027 BNI IOL A027 BNI IOL-771-000-A027 BNI IOL-772-000-A027 IO-Link Version 1.1 Universel IO-Link Interface With undervoltage / broken coil detection User s Guide Inhalt 1 Notes to the user 2 1.1. About this guide 2 1.2.

More information

Manual LioN-P - IO-Link Device - I/O Hub

Manual LioN-P - IO-Link Device - I/O Hub Manual LioN-P - IO-Link Device - I/O Hub 0960 IOL 381-001 0960 IOL 385-001 0960 IOL 380-021 Technical Support support-automation@belden.com Contents Contents 1 About this Manual 6 1.1 General Information

More information

Operating instructions. Monitor FR-1 / FR-1N / / 2013

Operating instructions. Monitor FR-1 / FR-1N / / 2013 Operating instructions Monitor FR-1 / FR-1N UK 7390953 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target

More information

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx EU Directive 2004/108/EC (EMC Directive) and EMC Law Generic Standards: EN 61000-6-4 (Emissions), EN 61000-6-2 (Interference Immunity) Emissions testing: Radio interference emissions EN 55011 Group 1,

More information

Operating instructions IO-Link INLINE DISPLAY 1.44" E30430

Operating instructions IO-Link INLINE DISPLAY 1.44 E30430 Operating instructions IO-Link INLINE DISPLAY 1.44" E30430 UK 80235800 / 00 02 / 2017 Contents 1 Safety instructions...2 2 Functions and features...3 3 Function...4 4 Installation...4 5 Electrical connection...4

More information

Operating instructions. Monitor FS-2 / FS-2N / / 2013

Operating instructions. Monitor FS-2 / FS-2N / / 2013 Operating instructions Monitor FS-2 / FS-2N UK 7390959 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target

More information

Batching Master xx0 (i)

Batching Master xx0 (i) Modbus Communication Batching Master xx0 (i) Revision 9.0 From software version 2.30 and 3.30 IBS BatchControl GmbH Im Sträßchen 2-4 Phone: +49 2441 9199 801 53925 Kall Fax.: +49 2441 9199 871 Germany

More information

Laser retro-reflective photoel. sensors with polariz. filter for bottles. Dimensioned drawing

Laser retro-reflective photoel. sensors with polariz. filter for bottles. Dimensioned drawing Technical data and description PRK3CL Laser retro-reflective photoel. sensors with polariz. filter for bottles Dimensioned drawing en 01-2016/07 50132447 3 khz 0 500mm 10-30 V DC We reserve the right to

More information

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing Dimensioned drawing en 2-214/2 5124879 25 4mm 15 13mm 15-3 V DC We reserve the right to make changes DS_HTU418BX3LT4_en_5124879.fm Largely surface-independent function, ideal for the detection of liquids,

More information

Operating instructions. Monitor FS-1 / FS-1N / / 2013

Operating instructions. Monitor FS-1 / FS-1N / / 2013 Operating instructions Monitor FS-1 / FS-1N UK 7390958 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target

More information

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12 Characteristics Pressure sensors XMLR 400bar - G 1/4-24VDC - 4..20 ma - PNP - M12 Complementary Current consumption Electrical connection Type of output signal Analogue output function Discrete output

More information

Dimensions. Model Number. Indicators/operating means. Features. Electrical connection. Product information OQT150-R100-2EP-IO-V31-L

Dimensions. Model Number. Indicators/operating means. Features. Electrical connection. Product information OQT150-R100-2EP-IO-V31-L Dimensions 21.5 8.7 5.5 11 1.5.2 M (2x).2.5 7.1 25. 1.2 10 15.9 7. 19.95 Reveiver Emitter ø.2 Model Number Triangulation sensor (SbR) with -pin, M8 x 1 connector Features Miniature design with versatile

More information

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

Operating instructions Electronic pressure sensor. PM205x /01 09/2011 Operating instructions Electronic pressure sensor PM205x 706071/01 09/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4

More information

Amplifiers, Counters, Timers & Controls

Amplifiers, Counters, Timers & Controls Amplifiers, Counters, Timers & Controls Panel Meter 814 Counter/Timer/Rate Indicator 815-817 Speed Monitor 818-819 Signal Converter 820-822 Power Supplies/Amplifier 823-824 813 Panel Meter Panel Meter

More information

Retro-reflective photoelectric sensors with polarization filter. Dimensioned drawing

Retro-reflective photoelectric sensors with polarization filter. Dimensioned drawing Dimensioned drawing en 01-2016/07 50130059 1,5 khz 0 3.5m 10-30 V DC We reserve the right to make changes DS_PRK3CT_Flaschen_en_50130059.fm Polarized retro-reflective photoelectric sensor with autocollimation

More information

Specification for IO-Link communication of Z/ISE20B(F)- -X101. Product Name:Pressure switch with IO-Link Model:ISE20B-T- -X101 ZSE20BF-T- -X101

Specification for IO-Link communication of Z/ISE20B(F)- -X101. Product Name:Pressure switch with IO-Link Model:ISE20B-T- -X101 ZSE20BF-T- -X101 :PS -PSV0007 Specification for IO-Link communication of Z/ISE20B(F)- -X101 Product Name:Pressure switch with IO-Link Model:ISE20B-T- -X101 ZSE20B-T- -X101 ZSE20BF-T- -X101 Pressure switch with IO-Link

More information

Optidrive Applications Support Library

Optidrive Applications Support Library Optidrive Applications Support Library Application Note Title AN-ODE-3-038 Related Products Optidrive E3 Overview Level 3 Modbus RTU Control and Register Mapping 1 Fundamental - No previous experience

More information

Flow sensors SFAB Key features

Flow sensors SFAB Key features Key features At a glance Quick and secure installation thanks to QS fitting Display can be rotated 270 Manifold assembly of the sensor via H-rail or individual assembly via adapter plate for wall mounting

More information

Operating instructions Binary level sensor LMTx0x LMTx1x LMTx2x

Operating instructions Binary level sensor LMTx0x LMTx1x LMTx2x Operating instructions Binary level sensor LMTx0x LMTx1x LMTx2x UK 80223649 / 01 05 / 2017 Contents 1 Preliminary note...3 1.1 Explanation of symbols...3 2 Safety instructions...4 3 Functions and features...4

More information

Capacitive Proximity Switches BCS R08RRE MicroBox

Capacitive Proximity Switches BCS R08RRE MicroBox Capacitive Proximity Switches BCS R08RRE MicroBox User's Guide english www.balluff.com english 1 Content Validity... 3 Notes to the user... 3 Symbols and conventions... 3 Downloading further instructions...

More information

PADPULS2 M-BUS Pulse Input Modules

PADPULS2 M-BUS Pulse Input Modules Product sheet MT8.23 Meter Type PADPULS2 PADPULS2 M-BUS Pulse Input Modules The M-PADPULS series of devices connects meters with contact output to the M-Bus system. This is a simple and flexible solution

More information

DATA LOGGER (Version V1.3)

DATA LOGGER (Version V1.3) WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland Tel. 0041 (0) 52 233 66 66 Fax. 0041 (0) 52 233 20 53 Homepage: http://www.wylerag.com E-Mail: wyler@wylerag.com Operating instructions DATA LOGGER (Version

More information

Dimensions. Model Number. Electrical connection. Features. Pinout. Product information. Indicators/operating means OMT300-R201-IEP-IO-V1

Dimensions. Model Number. Electrical connection. Features. Pinout. Product information. Indicators/operating means OMT300-R201-IEP-IO-V1 Dimensions. 9.9 6 Model Number 6.7 Ref. 6. 5. 5.8 7 7.7.6 ø. 9 50 78.5 Receiver Emitter M x..7 sensor with -pin, M x connector Electrical connection Features Medium design with versatile mounting options

More information

Model No Universal Input Indicator Start-up Guide

Model No Universal Input Indicator Start-up Guide Model No. 1480 Universal Input Indicator Start-up Guide Contents 1. Setting up a unit straight out of the box... 3 1.1. Entry into Configuration mode... 3 1.2. Scrolling through Parameters and s... 3 1.3.

More information

Instruction manual. Electronic pressure gauge (EPG) IM-TE91K033-EN5. Original manual

Instruction manual. Electronic pressure gauge (EPG) IM-TE91K033-EN5. Original manual Instruction manual Date of issue: September 22, 2014 First published: November 10, 2010 Original manual Alfa Laval Corporate AB This document and its contents is owned by Alfa Laval Corporate AB and protected

More information

Instructions. SMI Sensor Master Interface. Technical specification. Type label description. Device connector plug connection

Instructions. SMI Sensor Master Interface. Technical specification. Type label description. Device connector plug connection Instructions SMI Sensor Master Interface Technical specification Power supply: 5 VDC, ±0.25 V, 1 A (via Micro USB) Ambient temperature: 0... +40 C Storage temperature: 10 C... +50 C Protection: IP20 Dimension:

More information